INSTRUCTION MANUAL Oil level indicator with pointer

Size: px
Start display at page:

Download "INSTRUCTION MANUAL Oil level indicator with pointer"

Transcription

1 INSTRUCTION MANUAL Oil level indicator with pointer 5COL REV.01 I

2 II

3 CONTENTS 1. SAFETY Safety instructions Specified applications Safety notes on the equipment operation DRAWINGS OLI eoli Mounting flange OLI/eOLI (radial) OLI/eOLI (axial) OLI-22 / eoli-22 (Radial) OLI-22 / eoli-22 (Axial) L Radial Axial Viewer OPERATING PRINCIPLE Functioning Outputs Technical features Tests INSTALLATION Float assembly LA version (radial) LB version (axial) Oil level indicator: General information L OLI / eoli OLI-22 / eoli-22 (with special flange) Viewer ELECTRICAL CONNECTION Micro-switches wiring Analog output and Modbus communication wiring (for eoli and eoli-22) Power voltage Analog output Modbus communication (optional) Viewer wiring Power voltage Analog input Viewer eoli connections OPERATION AND MAINTANENCE Operation Maintenance Storage...14 APPENDIX A: MODBUS COMMUNICATION A1: MODBUS register...15 A1.1 MODBUS address...16

4 1. SAFETY 1.1 Safety instructions Make sure that any person installing: - Are technically qualified and competent. - Fully comply with these assembling instructions. Improper operations or misuse could cause danger to: Life and limb. To the equipment and other assets of the operator. To the equipment proper, function. Safety instructions in this manual are shown in three different forms to emphasize important information. WARNING This information indicates particular danger to life and health. Disregarding such a warning can lead to serious or fatal injury. CAUTION This information indicates particular danger to equipment and/or other property of the user. Serious or fatal injury cannot be excluded. NOTE This note gives important and specific information concerning the equipment. 1.2 Specified applications The oil level indicator is used in oil-insulated transformer to indicate the conservator tank oil level. Inside the device are usually installed up to four micro-switches to signal some critical oil levels. The micro-switches can give alarm or transformer power off signals. It is important to observe the limit values indicated on the nameplate and in the manual before commissioning the device. 1.3 Safety notes on the equipment operation Electrical installation is subject to the relevant national safety rules. It is mandatory to connect the grounding cable because of safety reason. CAUTION Installation, electrical connection and fitting the device have to be carried out by qualified personnel and only in accordance to this instruction manual. It is responsibility of the user to make sure that the device is used for specified application only. For safety matters, please avoid any unauthorized and improperly works. WARNING All relevant fire regulation must be strictly observed. 1

5 2.1 OLI 2. DRAWINGS 2.2 eoli Fig. 1 2 Fig. 2

6 2.3 Mounting flange OLI/eOLI (radial) OLI/eOLI (axial) Fig OLI-22 / eoli-22 (Radial) Fig. 4 3 Fig. 5

7 2.3.4 OLI-22 / eoli-22 (Axial) NOTE Mounting flange may be designed in accordance with customer s need: upon request, several hole patterns are available Fig L Radial Fig. 7 4

8 2.4.2 Axial Fig Viewer 5

9 3. OPERATING PRINCIPLE 3.1 Functioning The level gauge with magnetic joint is composed of a sturdy, watertight body made of aluminum alloy powder coated to protect against corrosion. The movement of the float rod and the pointer takes place thanks to magnetic coupling and reaches a 120 angle. In this way, for every variation of the oil inside the conservator tank the movement of the float cause the rotation of the magnet joint with consequent variation of the indication on the dial of the gauge. The pointer indicate the level that the oil should reach at the temperatures printed on the dial. The electronic version of the oil level gauge provide an analogical and a digital signal proportional to the oil level inside the conservator. These signals can be remote to : PLC, PC, integrated monitoring system, Remote Indicator. An electronic level indicator equipped with ma output signal can be coupled with the electronic Viewer. This device replicate the value of oil level (0-100%) at man-height. 3.2 Outputs STANDARD CONFIGURATION STANDARD (OLI-L140) OPTIONS (eoli) MICRO-SWITCHES ANALOG OUTPUT COMMUNICATION PORT RS-485 1, 2 or 4 change over contact (Fig.16) 4-20 ma (terminals 41-44) (Fig.17) (Minimum / Maximum resistance: 100 / 470 Ohm) Modbus communication (terminals 3-4)) (Fig.17) 3.3 Technical features Table 1 Material Dial All the external parts are resistant transformer oils, salt fog and UV rays. Tempered glass / Polycarbonate Standard color White RAL 9002** Ambient temperature Oil temperature Degree of protection Standard cable gland Wires Electronic board features, only for eoli Power supply (terminals 1-2) Power consumption Analogical output (terminals 5-6) Distance for analogical output Digital output (terminals 3-4) Distance for digital output Ventilation Valve Micro-switches features Power supply Power supply interruption -40 C +85 C -40 C +120 C IP65 according to EN x M25x1.5 OLI L140 3 x M25x1.5 eoli Max 2.5mm 2 advised 4x1mm 2 o 6x1mm 2 shielded twisted pair cable 24 Vdc ±10% polarized 0,5 W 4 20 ma (dielectric strength between electronic card and analogical output:1kv) Minimum / Maximum resistance: 100 / 470 Ω Max 30 m / 98 ft (for different demands contact COMEM) Serial RS485 Modbus RTU (for more information contact COMEM assistance dept.) Max 30 m / 98ft (for different demands contact COMEM) n.2 to prevent the formation of condensation 24V 220V ac/dc 3A 125/250V ac (resistive) 0.5A 125V dc for inductive load L/R=40ms 0.25A 250V dc for inductive load L/R=40ms 6

10 Electronic board features, only for Viewer Power supply (terminals 1-2) Analogical input (terminals 3-4) Distance for analogical input 24 Vdc ±10% polarized 4 20 ma (dielectric strength between electronic card and analogical output:1kv) Minimum / Maximum resistance: 100 / 470 Ω Max 30 m / 98 ft (for different demands contact COMEM) ** For critical environmental conditions please contact Comem Table Tests Description Reference standard Description Reference standard Fast transient/burs immunity test IEC Emission standard IEC (EN 55022) Conducted disturbances IEC Harmonic current emission EN Electrostatic discharge IEC Voltage fluctuations and flicker EN Supply variation IEC IP degree - IP 65 CEI EN Surge immunity test IEC Vibration Test CEI EN (Class 4M4) Magnetic field immunity test IEC Vibration Test IEC Power frequency magnetic field IEC Table 3 7

11 4. INSTALLATION CAUTION The operating and the installation requirements described in this manual must be strictly following. If not, the device can be damaged or a malfunction can occur. 4.1 Float assembly LA version (radial) Screw the arm (Fig 9/A) into the hole of the backside shaft and block it with the M4 nut (Fig.9/B). A B Fig LB version (axial) Insert the arm into the slot (Fig.10/A) on the backside shaft with and block it with the M5 nut (Fig.10/B). Fig. 10 A B 8

12 4.2 Oil level indicator: General information CAUTION Verify contact surface of the conservator. It must be well leveled with a good degree of roughness (Ra=3.2 micrometer). Verify and in case remove all welding burrs to ensure that the welding will not interfere with the housing flange holes. During the flange assembly, COMEM advice to apply a few drops of cyanoacrylate glue on the gasket to fix it at the oil level flange. This action guarantees a good gasket positioning and it facilitates the assembly Apply a specific tightening torque (max 20 Nm) on the nuts following a cross sequence. Depending on the conservator design, the level gauge can have different values of the parameters R and S (Fig.11) according to the table 4. Table 4 Fig S : parameter that indicates an offset from the vertical conservator axis [mm]. It is available for LA (radial) configuration. - R : parameter that indicates the length of the rod [mm]. It is available for LA (radial) and LB (axial) configurations. - ØDC : conservator diameter [mm]. NOTE For the LB configuration COMEM advice to fit it in the center of the conservator (S=0 mm) 9

13 4.3 L140 Insert the arm with float through the machined hole on the conservator. Place the o-ring on the slot behind the gauge. Insert the device on the threaded pin of the conservator flange (Fig12/A). The oil level indicator has to be mounted using the items (Fig.12/B) showed in the table 5. Q.ty Description Reference standard B 6 Ø6 plane washer UNI Ø6 grower washer UNI M6 nut UNI5588 A 1 OR Table 4 Fig OLI / eoli Align the flange (Fig.13/C) with the threaded pins or holes (Fig.13/A) (depending on the conservator flange type) and positioning between the conservator and the flange the flat gasket (Fig.13/B). The oil level indicator has to be assembled on the flange using four screws M4x12 (Fig.13/D). The oil level indicator flange has to be assembled using the items showed in the table 5. Qty Description Reference standard 4 Ø12 plane washer UNI Ø12 grower washer UNI1751 A 4 M12 nut UNI5588 B 1 Flat gasket - C Table 5 D Fig

14 4.5 OLI-22 / eoli-22 (with special flange) Insert the arm with float through the machined hole on the conservator. Place the o-ring in the slot behind the flange (Fig.14/C). Insert the flange on the threaded pins (Fig.14/A) of the conservator flange and fix it with the items showed in the table 6 (Fig.14/B). Fix the gauge on the flange using 4 screws M4x12 (Fig.14/D)). Q.ty Description Reference standard 8 Ø10 plane washer UNI Ø10 grower washer UNI1751 A 8 M10 nut UNI OR221 - Table 6 B C D Fig Viewer Arrange the transformer with a dedicated place following the scheme in the figure 15. The connection can be done in two alternative way: - threaded pin - screws Fig

15 5. ELECTRICAL CONNECTION CAUTION Qualified and skilled personnel trained in the applicable health and safety regulations of the relevant country should only perform electrical connections. WARNING Dangerous electrical voltages! It is imperative to deactivate the power supply during wiring of the device. CAUTION During the terminal box assembly, use caution not to damage the OR gasket (Fig.15/C). If this occurs, it must be substituted. If you do not use all the cable glands, pay attention to close the free cable gland with a plug with gasket. Remove the cover from the terminal box unscrewing the 4 captive screws M4 (Fig.15/C)). Insert the wires through the cable gland (Fig.15/B) and wiring them following the electrical scheme (Fig.16-17). C A B Fig Micro-switches wiring Wire the electrical cables in accordance with the ordered model following the electrical scheme showed in the Figure 16. It is possible to identify the wiring diagram from the device part number: E.g.: 1LB44X0000 the 5th letter identify the wiring diagram of the micro-switches DIAGRAM K DIAGRAM Y DIAGRAM X DIAGRAM W 12 Fig. 16

16 5.2 Analog output and Modbus communication wiring (for eoli and eoli-22) Power voltage Connect the power voltage (as written on the label on the terminal box cover) to terminals Vdc ±10% polarized Analog output Terminals for analog output 4-20 ma: 5-6 Minimum / Maximum resistance: 100 / 470 Ω 4 ma = 0% (minimum arrow position) 20 ma = 100% (maximum arrow position) Modbus communication (optional) Digital output RS485: terminals 3-4 (for the Modbus register and address, see the Appendix A) Fig Viewer wiring Power voltage Connect the power voltage (as written inside the terminal box, fig.18) to terminals Vdc ±10% polarized Analog input Connect the analog signal (as written inside the terminal box, fig. 18) to terminals ma Fig Viewer eoli connections The following scheme (fig.19) describes the connections for signal remoting between an electronic oil level indicator and the viewer. 13 Fig. 19

17 5 OPERATION AND MAINTANENCE The oil level indicator devices are ready for operation after installation, electrical connection and power supply. 6.1 Operation It is possible to detect the conservator oil level observing the indicator dial: Minimum level: when the pointer indicates the MIN position Maximum level: when the pointer indicates the MAX position. The electrical micro switches operate at an advance angle 5, with respect to the min or max indications of the oil level in the conservator. When there is a double contact, for e.g. double MIN and/or double MAX (schemes Y o W) the second contact operates at about 5 after the first contact. NOTE Comem advices to disconnect the eoli/eoli-22/viewer during the electrical transformer routine test 6.2 Maintenance During regular maintenance on the transformer, we recommend performing the following checks on the oil level indicator: Check the exterior condition of the device Remove dirt as necessary. 6.3 Storage The oil level indicators can be handled without any tools. Handle the device with care. CAUTION Not to paint the device. In this case any guarantees concerning the corrosion resistance decline. Only mild soap and water should be used to clean the electrical box cover. Solvents must not be used for any reason as they will degrade the performance of the paint. Use of solvents on the unit will immediately void the warranty. When you install the device, please follow section 4, 5 and 6. The oil level indicator must be stored in the original packing and in a dry place with temperature in the range C ( F). Upon receiving the device, please check: The outer surface of the packaging to ensure that it is intact That there are no breakages If damages are found, please contact COMEM and provide the information from the shipping list and the serial number. 14

18 APPENDIX A: MODBUS COMMUNICATION A1: MODBUS register Register address Operation Notes Operation for monitoring 0x2000 R Level value (0-100%) 0x2001 R Minutes from the last powering 0x2002 R Days from the last powering 0x2003 R Max level value (%) in the current day 0x2004 R Min level value (%) in the current day 0x2005 R Number of powering lost in the day 0x2006 R Minimum range value 0x2007 R Maximum range value 0x200A R Software version 0x2100 R Max level in the day 1 0x2101 R Min level in the day 1 0x2102 R Max level in the day 2 0x2103 R Min level in the day 2 0x2104 R Max level in the day 3 0x2105 R Min level in the day 3 Data logging 0x215C R Max level in the day X 0x215D R Min level in the day X 0x215E R Max level in the day Y 0x215F R Min level in the day Y 0x2300 R Events number 0x2301 R Timestamp Hi [Event 1]* 0x2302 R Timestamp Low [Event 1]* 0x2303 R Event type: value 4=Change Date[Event 1] 0x2304 R Level Value at the moment of the event [Event 1] 0x248D R Timestamp Hi [Event 100]* 0x248E R Timestamp Low [Event 100]* 0x248F R Event type: value 4=Change Date[Event 100] 0x2490 R Level Value at the moment of the event [Event 100] Events logging Table 7 *Date and time of an event are calculated in this way: Event Date/Time = Timestamp Hi (seconds) + (2 16 ) x Timestamp Low (seconds) + (01-Jan hh:00min:00sec) 15

19 A1.1 MODBUS address When are installed two or more units, it is necessary to differentiate the MODBUS address changing the dip-switches position The available eoli addresses are 128(default) to ADDRESS OFF OFF OFF OFF 128 OFF OFF OFF ON 129 OFF OFF ON OFF 130 OFF OFF ON ON 131 OFF ON OFF OFF 132 OFF ON OFF ON 133 OFF ON ON OFF 134 OFF ON ON ON 135 ON OFF OFF OFF 136 Fig. 18 ON OFF OFF ON 137 ON OFF ON OFF 138 ON OFF ON ON 139 ON ON OFF OFF 140 ON ON OFF ON 141 ON ON ON OFF 142 ON ON ON ON 143 Table 8 16

20 Strada Regionale 11, Signolo Montebello Vic.No (VI) - Italy Tel Fax comem@comem.com 17

OLI. Oil level indicator

OLI. Oil level indicator OLI Oil level indicator Oil level indicator Unexpected or accidental oil leakages may occur randomly along transformer s lifetime. Clear indication of oil level inside transformer tank and on load tap

More information

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34 LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34 2 LEVEL GAUGES WITH MAGNETIC JOINT SIZE Ø 140/220/340 58 58 TYPE LA TYPE LA 14 30 S 22 33 TYPE LA 22-34 NO. HOLES Ø D2 76 O-RING CENTRE OF THE CONSERVATOR

More information

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium

More information

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR 2 MB 103 TRANSFORMER TEMPERATURE CONTROL UNIT WITH CONTROL SIGNAL Recent approval of new

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

Elektromotoren und Gerätebau Barleben GmbH

Elektromotoren und Gerätebau Barleben GmbH Elektromotoren und Gerätebau Barleben GmbH OPERATING INSTRUCTIONS Transformer Protection Relay NM Series (Buchholz principle) Elektromotoren und Gerätebau Barleben GmbH Table of contents Page 1. Safety

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and

More information

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2 COMMERCIAL INSTALL GUIDE 2 Contents How to Use This Guide: The first section of this guide is designed to assist you with the installation of your DECK Monitoring hardware. The revenue grade meter and

More information

Elektromotoren und Gerätebau Barleben GmbH

Elektromotoren und Gerätebau Barleben GmbH Elektromotoren und Gerätebau Barleben GmbH OPERATING INSTRUCTIONS Transformer Protection Relay (Buchholz principle) Elektromotoren und Gerätebau Barleben GmbH Table of contents Page 1 Safety instructions

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

Series 6000 Torque measured metal bellow coupling

Series 6000 Torque measured metal bellow coupling Properties Free of float metal bellow coupling with integrated torque measurement Non-contact measurement system, high robustness High torsional stiffness Limited torque of inertia Performance Measurement

More information

OPL BASIC. Dosing System for Professional Laundry machines. Contents

OPL BASIC. Dosing System for Professional Laundry machines. Contents OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed. FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and

More information

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL PRODUCT NAME: CP/PB -150- EXPLOSION-PROOF-MANUAL CALL POINT/ PUSH BOTTON DOC NO.: EX-TECH SAS-12-CP-PB150-TM REV01 EXPLOSION-PROOF MANUAL CALL POINT/ PUSH BOTTON II 2GD EPL Gb, Db Ex d IIC T6, IP66 Ex

More information

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181 Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.

More information

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output. Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling

More information

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau KA 180F/00/en/06.01 (a) 52010984 Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau Safety instructions The FTS 20 floating switch may only be used as a level limit switch

More information

Description. Dimensions. Features. www.pwb-encoders.com. precision works better

Description. Dimensions. Features. www.pwb-encoders.com. precision works better Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

GREISINGER electronic GmbH

GREISINGER electronic GmbH T38.0.0X.6C-03 CO2 - Transmitter Operating Manual GT10 - CO2-1R GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 Tel.: +49 9402 / 9383-0, Fax: +49 9402 / 9383-33, email: info@greisinger.de

More information

HMI display Installation Guide

HMI display Installation Guide HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC

More information

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment

More information

Adjustment functions for both span and shift have been incorporated

Adjustment functions for both span and shift have been incorporated SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

Contents. Document information

Contents. Document information User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB

More information

Mounting Instructions. Torque Transducer. A0329 3.2 en

Mounting Instructions. Torque Transducer. A0329 3.2 en Mounting Instructions Torque Transducer T5 T5 Contents 3 Page Safety instructions.............................................. 4 1 Measuring characteristics..................................... 7 2 Mounting.....................................................

More information

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output

More information

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual 0 P a g e H.264 Color or Day/Night SurroundVideo Installation Manual Inside the box: A. Arecont Vision SurroundVideo camera B. Mounting template C. RJ45 female to female coupler D. Hex key E. Security

More information

Series 7500 Torque Sensor

Series 7500 Torque Sensor Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement

More information

Radiant Temperature Sensor TY7321

Radiant Temperature Sensor TY7321 AB-5361-U Specifications/Instructions Radiant Temperature TY7321 General TY7321 Radiant Temperature s are designed to measure infrared radiation from perimeter windows and walls and provide a proportional

More information

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01 ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions

More information

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular

More information

PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. PSDC 08128 v.1.2 PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. EN** Edition: 9 from 25.05.2015 Supersedes the edition: 8 from 12.12.2014 the 8x 1A/12V DC power output for powering

More information

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output

More information

ZC-24DO CANopen I/O Module: 24 Digital Outputs

ZC-24DO CANopen I/O Module: 24 Digital Outputs Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches

More information

Capacitive Prox E2K-X

Capacitive Prox E2K-X Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows

More information

T7560A,B,C Digital Wall Module

T7560A,B,C Digital Wall Module T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

Manual for Fire Suppression & Methane Detection System

Manual for Fire Suppression & Methane Detection System Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

LUCCI AIRFUSION QUEST II CEILING FAN

LUCCI AIRFUSION QUEST II CEILING FAN LUCCI AIRFUSION QUEST II CEILING FAN WITH IR REMOTE INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 QUEST II IR

More information

R O A D M A S T E R, I N C.

R O A D M A S T E R, I N C. R O A D M A S T E R, I N C. ROADMASTER, Inc. 6110 NE 127th Ave. Vancouver, WA 98682 12 10 3 11 4 5 13 7 8 360-896-0407 fax 360-735-9300 www.roadmasterinc.com ITEM QTY NAME MATERIAL 1... 4...1/2 x 1 1/2

More information

Toroidal Conductivity Sensor

Toroidal Conductivity Sensor Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:

More information

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants Sendix 5000 / 500 (Shaft / Hollow shaft) Push-Pull / RS4 ue to their sturdy bearing construction in Safety-ock esign, the Sendix 5000 and 500 offer high resistance against vibration and installation errors.

More information

Fire Pump Applications

Fire Pump Applications Fire Pump Applications Installation & Maintenance Manual Universal Joint Driveshafts www.cumminsfirepower.com Table of Contents Section 1 General 1.1 Introduction 1.2 Safety Precautions 1.3 Warranty Statement

More information

How To Use A Ds340 (Dsp)

How To Use A Ds340 (Dsp) Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions

More information

Instruction Manual Differential Pressure Transmitter

Instruction Manual Differential Pressure Transmitter DE28 Instruction Manual Differential Pressure Transmitter Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance

More information

Technical Data Sheet. 3DLevelScanner

Technical Data Sheet. 3DLevelScanner Changing the market from level to volume Technical Data Sheet APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

Reaction Torque Sensor

Reaction Torque Sensor Force 1 1 N m up to 1 000 1 000 N m Type 9329A 9389A These easy to install piezoelectric reaction torque sensors are particularly suitable for measuring rapidly changing torques at non-rotating shafts.

More information

ORTHOBLOC 3000. Drive systems. Installation. This manual is to be given to the end user. 3996 en - 2013.04 / k. R max - 5 mm.

ORTHOBLOC 3000. Drive systems. Installation. This manual is to be given to the end user. 3996 en - 2013.04 / k. R max - 5 mm. en - 01.0 / k 1 en This manual is to be given to the end user --> B7 (0 to 0 ) R max - mm R min + mm ORTHOBLOC 000 Installation LEROY-SOMER Ot 000 en - 01.0 / k NOTE LEROY-SOMER reserves the right to modify

More information

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual Instruction Manual OPC-LM1-IL Option Card for Encoder of Line Driver Output CAUTION Deliver this instruction manual without fail to those who actually operate the equipment. Read this operation manual

More information

R O A D M A S T E R, I N C.

R O A D M A S T E R, I N C. R O A D M A S T E R, I N C. 11 10 20 12 4 18 19 1 2 13 16 ITEM QTY NAME MATERIAL 1...2... 1/2" x 3 1/2" BOLT... 350103-00 2...2... 1/2" x 2" BOLT... 350097-00 3...6... 1/2" x 1 1/2" BOLT... 350095-00 4...2...

More information

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL CAUTION CONNECTION DIAGRAM

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL CAUTION CONNECTION DIAGRAM USER S GUIDE EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL The EE210 transmitter, available for wall or duct mounting, is designed for the highly accurate

More information

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve 9700 NAMUR series, / & / > > Port size: G/, / NPT, NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve > > Manual

More information

SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval

SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval series Light Curtain Sensors New type with radial cross ray method Small objects and flat tape-like objects detected Convenient simplified wiring requiring no clock (synchronization) line Compact and flat

More information

TX OPEN RS232/485 module

TX OPEN RS232/485 module s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

Mounting instructions. Junction box VKK2R-8 DIGITAL. A1145-1.0 en

Mounting instructions. Junction box VKK2R-8 DIGITAL. A1145-1.0 en Mounting instructions Junction box VKK2R-8 DIGITAL VKK2R-8 DIGITAL 3 Contents Page Safety instructions... 4 1 Introduction and appropriate use... 7 2 Mechanical construction... 8 2.1 Mounting... 9 3 Electrical

More information

Antenna Splitter ASA 1. Instruction manual

Antenna Splitter ASA 1. Instruction manual Antenna Splitter ASA 1 Instruction manual Contents Important safety instructions... 2 The ASA 1 active antenna splitter... 4 Delivery includes... 4 Operating elements... 5 Putting the ASA 1 into operation...

More information

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2 Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened

More information

3DLevelScanner II TECHNICAL DATA SHEET

3DLevelScanner II TECHNICAL DATA SHEET TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all

More information

AXIS T81B22 DC 30W Midspan

AXIS T81B22 DC 30W Midspan INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial

More information

ATL Fuel Level Sender Probes

ATL Fuel Level Sender Probes T E C H N I C A L S P E C I F I C A T I O N The ATL EL-AD-151 (Resistance Output) and EL-AD-152 (Voltage Output) Fuel Level Senders are highly advanced sensors for continuously measuring the contents of

More information

R O A D M A S T E R, I N C.

R O A D M A S T E R, I N C. R O A D M A S T E R, I N C. ROADMASTER, Inc. 6110 NE 127th Ave. Vancouver, WA 98682 6 13 11 MOUNTING BRACKET KIT Cable Tab 14 12 7 15 9 Cable Tab 360-896-0407 fax 360-735-9300 www.roadmasterinc.com ITEM

More information

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB100-0100

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB100-0100 WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.

More information

Output torques up to 8000 Nm. General features. Protection. External coating. Working temperature range

Output torques up to 8000 Nm. General features. Protection. External coating. Working temperature range Type series booklet 8521.15/2--10 ACTELEC 31 to 800 (BERNARD) 1/4 turn electric actuators (irreversible reducer with multi -turn electric actuator ACTELEC 31: screw -nut kinematics ACTELEC 200 to 800:

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Samba OPLC SM35-J-R20 Installation Guide The Unitronics SM35-J-R20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include: 1 HSC/Shaft-encoder Input, 2 Analog inputs (only

More information

Machine Safety Switches

Machine Safety Switches Machine Switches SI-LS31H Series 31 mm Limit-Switch-Style with Hinged Lever Actuators Features Limit switch design (EN 50047) For use on doors or flaps Positive opening safety contacts (IEC 60947-5-1)

More information

Operation Manual For NDJ-8S Digital Rotary Viscometer

Operation Manual For NDJ-8S Digital Rotary Viscometer Operation Manual For NDJ-8S Digital Rotary Viscometer 1 Contents 1. General... 2 2. Main technical data... 2 3. Working principle... 2 4. Installation... 3 5. Operation procedures... 4 6. Precautions...

More information

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

Day / Night IR Color Camera User Manual V2.1.0

Day / Night IR Color Camera User Manual V2.1.0 Day / Night IR Color Camera User Manual V2.1.0 1 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to DS-2CC102P(N)-IR1(IR3)(IR5),

More information

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

FN2001-A1 Network module (SAFEDLINK) Mounting Installation FN00-A Network module (SAFEDLINK) Mounting Installation A6V050_f_en_-- 05-0-6 Building Technologies Division Legal notice Legal notice Technical specifications and availability subject to change without

More information

DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30 85 320/215 ED DXPE*J DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK SUBPLAtE MOUNtINg DXPE5J CEtOP P05 DXPE5RJ ISO 4401-05 (CETOP R05) DXPE7J ISO 4401-07 (CETOP 07) DXPE8J ISO 4401-08

More information

SureSite Magnetic Liquid Level Indicator

SureSite Magnetic Liquid Level Indicator SureSite Magnetic Liquid Level Indicator Instruction Bulletin No. 177664-1 (Rev. E) Section 1: Weldments Thank you for purchasing the GEMS SureSite Magnetic Level Indicator. Please read this document prior

More information

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding

More information

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS Frames 143T - 449TZ 5100 North IH 35 Round Rock, Texas 78681 Phone: 800-451-8798 512-255-4141 Fax: 512-244-5512 RECEIVING 1. Check

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases Detector Color Detector transparent with Color Inserts FAA 500 TR W Trim Ring FAA 500 TR P Trim Ring transparent with Color Inserts FAA 500 BB Ceiling Mount Back Box FCA 500 / FCA 500 E Detector Bases

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014 EZmoto V2 Product description Rev. 6 10/01/2014 1 Contents 1. Overview... 3 2. Hardware Interface Description... 3 2.1 Main features of the EZmoto... 3 2.2 Hardware block diagram... 4 2.3 Internal Hardware

More information

Addendum to the Operating Instructions

Addendum to the Operating Instructions Drive Technology \ Drive Automation \ System Integration \ Services Addendum to the Operating Instructions MOVIMOT with AS-Interface and AC Motor DT/DV Unit Replacement MOVIMOT MM..C -> MM..D with MLK3A

More information

Vert-X 16-5V / 10...90% Ub. Applications Servodrives Dancer arm Operating table

Vert-X 16-5V / 10...90% Ub. Applications Servodrives Dancer arm Operating table Version MH-C MH-C2 Electrical data Measuring range 0... 360 - Indep. linearity % meas. range ±0.3 - Max. hysteresis 0.1 - Resolution bit 12 - Max. repeatability 0.1 - Sample rate fast mode khz (5) - Sample

More information

! WARNING. Before using product, read and understand instructions.

! WARNING. Before using product, read and understand instructions. McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes

More information

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws Compact Pre-wired Photomicrosensor with Built-in Amplifier (Non-modulated) CSM DS_E_7_2 Meeting Customer Needs with Compact Sensors that Mount with M Screws Both light-on and dark-on outputs provided.

More information

Machine Safety Switch: SI-LM40 Series Limit Switch Style

Machine Safety Switch: SI-LM40 Series Limit Switch Style Machine Switch: SI-LM40 Series Limit Switch Style SI-LM40 Series Limit Switch Style with Flexible In-Line Actuator Positive-opening safety contacts (IEC 60947-5-1) (not dependent upon springs) Standard

More information

Reliance DuraStar ORDINARY LOCATION INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS

Reliance DuraStar ORDINARY LOCATION INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS STORAGE and HANDLING The LED Illuminator meets or exceeds all applicable specifications when shipped from the factory. All units should be inspected upon receipt to ensure that no damage has been incurred

More information

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads: Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:

More information

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input

More information

BNI EIP-950-000-Z009 IP67 Module, Unmanaged Switch

BNI EIP-950-000-Z009 IP67 Module, Unmanaged Switch BNI EIP-950-000-Z009 IP67 Module, Unmanaged Switch Balluff Ethernet IP, BNI EIP-104-100-Z016 1 Notes to the User 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typgraphical Conventions 2 1.4 Symbols

More information

D.C. Motors. Products and specifications subject to change without notice.

D.C. Motors. Products and specifications subject to change without notice. D.C. Motors Order/Technical Support - Tel: (8) 677-5 / FAX: (8) 677-865 / www.crouzet-usa.com / DC Motors Selection guide Gearbox Speed Torque max (Nm).5. Type of Gearbox 8 8 8. Power usable (w) Torque

More information

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches

More information

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 www.atos.com Table F040-1/E Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 AGMZO are two stage poppet type proportional

More information