INSTRUCTION MANUAL. Compressor Nebulizer NE-C801
|
|
|
- Philippa Andrews
- 9 years ago
- Views:
Transcription
1 INSTRUCTION MANUAL TM Compressor Nebulizer NE-C801 Caution: Federal (USA) law restricts this device to sale by or on the order of a physician or licensed healthcare practitioner ENGLISH ESPAÑOL
2 CONTENTS Before Using the Device Introduction Intended Use Safety Information...5 Know Your Unit...9 Operating Instructions Preparing the Nebulizer for Use Attaching the Air Tube Using the Device...15 Care and Maintenance Cleaning after Each Use Daily Disinfecting Changing the Air Filter Caring for the Device Troubleshooting Troubleshooting Guide Limited Warranty...23 FCC Statement...24 Specifications...25 Technical Data...26 Guidance and Manufacturer's Declaration...27 The illustrations shown in this instruction manual are image drawings and may differ slightly from the appearance of the actual product. 2
3 Before Using the Device Introduction Thank you for purchasing the OMRON NE-C801 Compressor Nebulizer. Fill in for future reference. DATE PURCHASED: SERIAL NUMBER: Staple your purchase receipt here Register your product on-line at This product was developed for the successful treatment of asthma, allergies and other respiratory disorders. The compressor forces air to the nebulizer. When the air enters the nebulizer, it converts the prescribed medication into an aerosol of microscopic droplets that can easily be inhaled. Your NE-C801 Compressor Nebulizer comes with the following components: Compressor (Main Unit) Nebulizer Kit Mouthpiece Air Tube (PVC, 100 cm) AC Adapter Air Filters (Package of 5) Storage Bag Instruction Manual The following are optional accessories sold separately: Nosepiece Adult Mask (PVC) Child Mask (PVC) Please read this instruction manual thoroughly before using the unit. Please keep for future reference. For specific information about your own nebulizer, CONSULT YOUR DOCTOR. SAVE THESE INSTRUCTIONS 3
4 Intended Use The NE-C801 Compressor Nebulizer System is intended to provide air to the pneumatic nebulizer in order to aerosolize medications for inhalation by the patient for respiratory disorders. The system is designed for use with pediatric (defined by the prescribed medication) and adult patients in the home, hospital, and sub-acute settings. All warnings and cautions described in this manual should be observed. 4
5 Safety Information To ensure the correct use of the product, basic safety measures should always be followed including the warnings and cautions listed in this instruction manual. SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL WARNING CAUTION Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property. Operating the Device For type, dose, and regime of medication follow the instructions of your physician or licensed healthcare practitioner. If you feel anything unusual during use, stop using the device immediately and consult your physician. Do not cover the compressor with a blanket, towel, or any other type of cover during use. This could result in the compressor overheating or malfunctioning. Do not use the device where the device may be exposed to flammable gas or vapors. Do not use tap or mineral water in the nebulizer for inhaling purposes. Clean and disinfect the nebulizer kit, mouthpiece, and optional nosepiece or optional masks before using them for the first time after purchase. If the device has not been used for a long period of time, clean and disinfect the nebulizer kit, mouthpiece, and optional nosepiece or optional masks before using them. Pentamidine is not an approved medication for use with this device. Always dispose of any remaining medication in the medication cup after each use. Use fresh medication each time you use the device. Do not leave the device or its parts where it will be exposed to extreme temperatures or changes in humidity, such as leaving the device in a vehicle during warm or hot months, or where it will be exposed to direct sunlight. Do not use or store the device where it may be exposed to noxious fumes or volatile substances. Make sure that the nebulizer kit is clean before use. Do not use in anaesthetic or ventilator breathing circuits. Not suitable for use in the presence of flammable anesthetic mixture with air or oxygen or nitrous oxide. 5
6 OPERATING THE DEVICE (continued) Do not operate where oxygen is being administered in a closed environment (such as an oxygen tent). Provide close supervision when this device is used by, on, or near infants, children or compromised individuals. If the device is used continuously, the service life of the device may be shortened. Limit use to 20 minutes at a time, and allow a 40 minutes interval before using the device again. When using the device, the main unit may become hot. Do not touch the main unit for other than necessary operation such as turning off the power while nebulizing. Do not insert any object into the compressor. Make sure the air filter is clean. If the air filter has changed color or has been used on average for more than 60 days, replace it with a new one. Make sure the nebulizer kit is correctly assembled, the air filter is properly installed, and the air tube is correctly connected to the compressor and the nebulizer kit. Air may leak from the air tube during use if not securely connected. Inspect the compressor (main unit) and the nebulizer parts each time before using nebulizer kit. Make sure no parts are damaged, the nozzle and air tube are not blocked and the compressor operates normally. Do not use the device if the air tube is bent. Do not block the air filter cover. Safety Information Do not alter the baffle, the nozzle in the medication cup or any part of the nebulizer kit. Do not add more than 7mL of medication to the medication cup. Do not operate the device at temperatures greater than +40 C (+104 F). Do not tilt the nebulizer kit so the angle of the kit is greater than 45. Medication may flow into the mouth. Do not shake the nebulizer kit while using the device. Do not subject the compressor or any of the components to strong shocks, such as dropping on the floor. This device is approved for human use only. Do not disassemble or attempt to repair the device or components. Operate the device only as intended. Do not use the device for any other purpose. 6
7 OPERATING THE DEVICE (continued) Safety Information Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution. Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device do not perform the expected specification or it may damage the unit. Changes or modification not approved by Omron Healthcare will void the user warranty. To avoid injury to the nose mucosa, do not squeeze the optional nosepiece into the back of the nose. To avoid the medication residue on the face. After nebulization, be sure to wipe the face after removing the optional masks. When using this device, there will be some noise and vibration caused by the pump in the compressor. There will also be some noise caused by the emission of compressed air from the nebulizer kit. This is normal and does not indicate a malfunction. When sterilizing parts by boiling, make sure that the container does not boil dry. Do not use the device while sleeping or if drowsy. Do not block the slit between the cap and the inhalation air inlet. Risk of Electrical Shock Do not connect the AC adapter terminal using wire or other metallic conductors. Do not use the compressor (main unit) or AC adapter while they are wet. Do not plug or unplug the AC adapter into the electrical outlet with wet hands. Do not immerse the compressor (main unit) in water or other liquid. Do not spill water or other liquids on the compressor and AC adapter. These parts are not waterproof. If liquid spills on these parts, immediately unplug the AC adapter and wipe off the liquid with gauze or other soft absorbent material. Do not use or store the device in humid locations, such as a bathroom. Use the device within the operating temperature and humidity. Use only the AC adapter designed by Omron for this device. Use of any other AC adapter may damage the device. Do not operate the device with a damaged power cord or plug. Do not use a cellular phone near the device. It may result in an operational failure. 7
8 Safety Information Risk of Electrical Shock (continued) Do not overload power outlets. Plug the AC adapter into the appropriate voltage outlet. Do not use extension cords. Plug the AC adapter directly into the electrical outlet. Unplug the AC adapter from the electrical outlet after using the device. Remove the AC adapter from the device after use. Unplug the AC adapter from the electrical outlet before cleaning the device. Do not pull the power cord of AC adapter strongly. Maintenance and Storage Keep the device out of the reach of unsupervised infants and children. The device may contain small parts that can be swallowed. Do not leave the cleaning solution in the nebulizer parts. Rinse the nebulizer parts with clean hot tap water after disinfecting. Wash the nebulizer parts after each use. Dry the parts immediately after washing. Do not store the air tube with moisture or medication remaining in the air tube. This could result in infection as a result of bacteria. Store the device and the components in a clean, safe location. Do not carry or leave the nebulizer kit with medication in the medication cup. Do not place or attempt to dry the device, components or any of the nebulizer parts in a microwave oven. Do not wrap the power cord around the compressor (main unit) and AC adapter. 8
9 Components and Replacement Parts Know Your Unit Nebulizer Kit Compressor (Main Unit) Nebulizer Kit Holder Air Tube Plug Air Tube Plug Air Tube Connector Power Switch Back View Air Tube (PVC, 100 cm) NOTE: Only use the NE-C801 Nebulizer Kit with this Nebulizer. Cap Inhalation Air Inlet Inhalation Top Nebulizer Kit Mouthpiece Air Filter Cover *Air filter inside Power Connector Baffle Nozzle Medication Cup Air Tube Connector 9
10 Caution: Federal (USA) law restricts this device to sale by or on the order of a physician or licensed healthcare practitioner Components: Air Filters Package of 5 KNOW YOUR UNIT Instruction Manual INSTRUCTION MANUAL Storage Bag Compressor Nebulizer NE-C801 ENGLISH ESPAÑOL Terminal AC Adapter Power Cord Power Plug Accessories and Replacement Parts Model No. AC Adapter C30AC Adult Mask (PVC) Child Mask (PVC) Air Filters (Package of 5) C30FL Air Filter Cover C801FC Air Tube (PVC, 100 cm) C801AT Nebulizer Kit Set C801NEB Includes Nebulizer Kit, Mouthpiece and Air Tube Nosepiece... C911 Mouthpiece C910 10
11 Operating Instructions Preparing the Nebulizer for Use WARNING Clean and disinfect the nebulizer kit, mouthpiece, and optional nosepiece or optional masks before using them for the first time after purchase. If the device has not been used for a long period of time, or if more than one person uses the same device, clean and disinfect the nebulizer kit, mouthpiece, and optional nosepiece or optional masks before using them. CAUTION Make sure the air filter is clean. If the air filter has changed color or has been used on average for more than 60 days, replace it with a new one. For directions on cleaning and disinfecting refer to page For directions on changing the air filter refer to page Insert the power plug on the AC adapter into the power connector on the back side of the compressor. Plug the AC adapter into the electrical outlet. WARNING Do not plug or unplug the AC adapter into the electrical outlet with wet hands. CAUTION Do not overload power outlets. Plug the AC adapter into the appropriate voltage outlet. Do not use extension cords. Plug the AC adapter directly into the electrical outlet. Power Plug Electrical Outlet Power Connector NOTE: AC adapter can be worked at V ~ 350mA, 50/60 Hz. 2 Lift up the mouthpiece and the cap to remove them from the nebulizer kit. 11
12 PREPARING THE NEBULIZER FOR USE 3 Rotate the inhalation top counterclockwise (A) and lift (B) to remove the inhalation top from the medication cup. 4 Add the correct amount of prescribed medication to the medication cup. WARNING For type, dose, and regime of medication follow the instructions of your physician or licensed healthcare practitioner. Do not spill water or other liquids on the compressor and AC adapter. These parts are not waterproof. If liquid spills on these parts, immediately unplug the AC adapter and wipe off the liquid with gauze or other soft absorbent material. Do not use tap or mineral water in the nebulizer for inhaling purposes. CAUTION Do not add more than 7mL of medication to the medication cup. NOTE: Scales on the nebulizer kit are for reference only. The scale on the outside of the medication cup is with no baffle in place. Please use the scale on your syringe or vial for accurate measurement of medication. 5 Make sure that the baffle is securely attached to the inhalation top. 6 Place the inhalation top on the medication cup. Align the protrusion on the inhalation top with the indentation on the medication cup as illustrated (A). Turn the inhalation top clockwise until securely closed (B). 12
13 PREPARING THE NEBULIZER FOR USE 7 Attach the desired inhalation accessory. USING THE MOUTHPIECE Place the cap on the medication cup over the inhalation air inlet (A). Attach the mouthpiece (B). NOTE: Place the cap on the medication cup when using the mouthpiece. Using the cap with the mouthpiece will reduce the amount of medication that is discharged into the air. USING THE NOSEPIECE (Optional) Place the cap on the medication cup over the inhalation air inlet (A). Attach the nosepiece (B). NOTE: Place the cap on the medication cup when using the nosepiece. Using the cap with the nosepiece will reduce the amount of medication that is discharged into the air. USING THE CHILD MASK (Optional) Place the cap on the medication cup over the inhalation air inlet (A). Attach the child mask (B). NOTE: If the amount of aerosol is too small, it is not necessary to place the cap. USING THE ADULT MASK (Optional) Attach the adult mask to the inhalation top. NOTE: If the amount of aerosol is too much, place the cap on the medication cup over the inhalation air inlet. 13
14 Attaching the Air Tube 1 Twist the air tube plug slightly and push it firmly into the air tube connector on the upper side of the compressor (A). 2 Twist the air tube plug slightly and push it firmly into the air tube connector on the bottom of the nebulizer kit (B). NOTE: Keep the nebulizer kit upright when attaching the air tube. Medication may spill out of the medication cup. CAUTION Make sure the nebulizer kit is correctly assembled, the air filter is properly installed, and the air tube is correctly connected to the compressor and the nebulizer kit. Air may leak from the air tube during use if not securely connected. Do not use the device if the air tube is bent. 3 Use the nebulizer kit holder as a temporary holder for the nebulizer kit. NOTE: Align the mark on the unit with the mark on the nebulizer kit as shown. 14
15 WARNING Do not use the device where the device may be exposed to flammable gas or vapors. Do not use or store the device in humid locations, such as a bathroom. Use the device within the operating temperature and humidity. CAUTION Using the Device Provide close supervision when this device is used by, on, or near infants, children or compromised individuals. Do not use a cellular phone near the device. It may result in an operational failure. Inspect the compressor (main unit) and the nebulizer parts each time before using the device. Make sure no parts are damaged, the nozzle and air tube are not blocked and the compressor operates normally. 1 Hold the nebulizer kit as illustrated on the right. CAUTION Do not tilt the nebulizer kit so the angle of the kit is greater than 45. Medication may flow into the mouth. Do not shake the nebulizer kit while using the device Turn the power switch to the on ( ) position. As the compressor starts, nebulization begins and aerosol is generated. To stop nebulization, turn the power switch to the off ( ) position. WARNING Do not cover the compressor with a blanket, towel, or any other type of cover during use. This could result in the compressor overheating or malfunctioning. 15
16 CAUTION Do not block the air filter cover. USING THE DEVICE Limit use to 20 minutes at a time, and allow a 40 minutes interval before using the device again. When using the device, the main unit may become hot. Do not touch the main unit for other than necessary operation such as turning off the power while nebulizing. 3 Inhale medication as instructed by your physician or licensed healthcare practitioner. USING THE MOUTHPIECE Insert the mouthpiece into your mouth. Inhale medication breathing normally. Exhale normally through the mouthpiece. USING THE NOSEPIECE (Optional) Inhale the medication through the nosepiece as illustrated. Exhale through the mouth. USING THE CHILD MASK or the ADULT MASK (Optional) Place the mask over the nose and mouth. Pull the elastic strap over the head. Gently pull on the strap to secure the mask over the nose and mouth. Inhale the medication. Exhale normally through the mask. 4 Complete the treatment. WARNING For type, dose, and regime of medication, follow the instructions of your physician or licensed healthcare practitioner. 16
17 USING THE DEVICE 5 Turn the power switch to the off ( ) position. The compressor turns off and nebulization stops. 6 Disconnect the air tube from the nebulizer kit. Hold the air tube plug and gently pull down to disconnect the air tube plug from the air tube connector on the bottom of the nebulizer kit. 7 Check the air tube. No condensation or moisture should remain in the air tube. WARNING Do not store the air tube with moisture or medication remaining in the air tube. This could result in infection as a result of bacteria. If any condensation or moisture remains in the air tube, remove the moisture from the air tube. Follow the directions below: 1. Make sure the air tube is still connected to the air tube connector on the upper side of the compressor. 2. Press the power switch on. The compressor will start and pump air through the air tube to expel the moisture. 3. Press the power switch again to turn the compressor off. 8 Disconnect the air tube from the compressor. Hold the air tube plug and gently pull the air tube plug off the air tube connector on the upper side of the compressor. 9 Unplug the AC adapter from the electrical outlet. CAUTION Unplug the AC adapter from the electrical outlet after using the device. Remove the AC adapter from the device after use. Do not pull the power cord of AC adapter strongly. 17
18 Care and Maintenance Cleaning after Each Use Following cleaning instructions after each use will prevent any remaining medication in the bottle from drying resulting in the device not nebulizing effectively and will help prevent infections. WARNING Wash the nebulizer parts after each use. Dry the parts immediately after washing. 1 Remove the inhalation accessory (mouthpiece, optional masks, or optional nosepiece) from the nebulizer kit. 2 Disconnect the air tube from the nebulizer kit. 3 Gently twist the inhalation top counterclockwise and lift to separate the nebulizer into two sections. 4 Discard remaining medication in the medication cup. WARNING Always dispose of any remaining medication in the medication cup after each use. Use fresh medication each time you use the device. 5 Rinse all the parts with hot tap water. 6 Hand dry or air dry in a clean environment using a soft, clean, lint-free cloth. 7 Assemble the nebulizer kit and store it in a dry bag. 18
19 Daily Disinfecting Disinfect the nebulizer kit and mouthpiece, or optional masks or optional nosepiece after the last treatment of the day. To disinfect the parts, use one of the methods described below: A. Use a commercially available disinfectant. Follow the instructions provided by the disinfectant manufacturer. 1 Submerge the parts in the cleansing solution for the specified period. 2 Remove the parts and discard the solution. 3 Rinse the parts with clean hot tap water, shake off excess water and allow to air dry in a clean environment. B. Parts may be boiled between 15 to 20 minutes. After boiling, carefully remove the parts, shake off excess water and allow to air dry in a clean environment. NOTE: Do not boil air tube, air filter, air filter cover and optional masks. CAUTION Do not use an autoclave, EOG gas disinfection or low temperature plasma sterilizer to disinfect the device. Handling the Baffle The baffle is an important part that is used to nebulize medication. Be sure to observe the following precautions when handling it. CAUTION Always wash the baffle after each use. Do not use a brush or pin etc., to clean the parts. When disinfecting the parts by boiling, be sure to boil them in plenty of water. Do not boil the baffle together with other objects, other than applicable nebulizer accessories. Do not use a microwave oven, dish dryer or hair dryer to dry parts. 19
20 Changing the Air Filter If the air filter has changed color or has been used on average for more than 60 days, replace it with a new one. If water or medication has spilled on the air filter, replace with a new air filter immediately. 1 Pull the air filter cover to remove from the back side of the compressor. 2 Remove the dirty air filter. CAUTION Do not attempt to wash or clean the air filter. Damp air filters can cause blockages. Do not substitute cotton or any other material for the air filter. Wash the air filter cover regularly to prevent any blockage in the cover. Do not boil. Make sure the cover is dry before inserting the new air filter. 3 Insert a new air filter. CAUTION Before inserting the new air filter make sure the air filter is clean and free of dust. Do not operate the device without the air filter. Use only the Omron air filter designed for this device. 4 Put the air filter cover back on the compressor. 20
21 To keep your device in the best condition and protect the unit from damage, follow these directions: CAUTION Caring for the Device Do not subject the compressor or any of the components to strong shocks, such as dropping on the floor. Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device do not perform the expected specification or it may damage the unit. CLEANING THE COMPRESSOR Clean the casing of the main unit by using a soft cloth moistened with water or a mild detergent. Do not use abrasive cleaners. Dry the casing immediately using a soft clean cloth. WARNING Do not immerse the compressor (main unit) in water or other liquid. CAUTION Unplug the AC adapter from the electrical outlet before cleaning the device. Do not insert any object into the compressor. STORING THE DEVICE Place the compressor, the nebulizer kit and the inhalation accessory (air tube, mouthpiece, optional masks and optional nosepiece) in the storage bag. Store it in a safe, clean location. WARNING Do not leave the device or its parts where it will be exposed to extreme temperatures or changes in humidity, such as leaving the device in a vehicle during warm or hot months, or where it will be exposed to direct sunlight. Keep the device out of the reach of unsupervised infants and children. The device may contain small parts that can be swallowed. CAUTION Do not carry or leave the nebulizer kit with medication in the medication cup. Do not wrap the power cord around the compressor (main unit). 21
22 Troubleshooting Troubleshooting Guide PROBLEM No power to unit when the power switch is on. No nebulization or low nebulization rate when the power is on. The device is abnormally loud. The device is very hot. Cause The AC adapter is not plugged into an electrical outlet. No medication in the medication cup. Too much or too little medication in the medication cup. The baffle is not attached to the inhalation top or incorrectly positioned. The nebulizer kit is not correctly assembled. The nozzle is blocked. The nebulizer kit is tilted at an incorrect angle. The air tube is incorrectly attached. The air tube is folded or damaged. The air tube is blocked. The air filter is dirty. The air filter cover is incorrectly attached. The compressor is covered. Operating continuously over 20 minutes. SOLUTION Turn the power switch off. Plug the AC adapter into an electrical outlet. Turn the device on. Add the correct amount of prescribed medication to the medication cup. Make sure the baffle is correctly attached to the inhalation top. Make sure the nebulizer kit is correctly assembled and the inhalation accessory is correctly attached. Clean and disinfect the nebulizer kit to remove the blockage. Hold the nebulizer kit correctly. Do not tilt the nebulizer kit so the angle of the kit is greater than 45 degrees. Make sure the air tube is correctly attached to the compressor and the nebulizer kit. Make sure the air tube is not folded, kinked or bent. Inspect the air tube for any damage. Replace the air tube if damaged. Replace the air filter with a new clean air filter. Attach the air filter cover correctly. Make sure the air filter cover is not blocked. Do not cover the compressor with any type of cover during use. Limit use to 20 minutes at a time and allow a 40 minutes interval before using the device again. 22
23 Limited Warranty Your OMRON NE-C801 Compressor Nebulizer, excluding the nebulizer kit, inhalation accessories, air tube and air filters, is warranted to be free from defects in materials and workmanship appearing within 3 years from the date of purchase, when used in accordance with the instructions provided with the compressor nebulizer. The above warranties extend only to the original retail purchaser. We will, at our option, repair or replace without charge any compressor nebulizer covered by the above warranties. Repair or replacement is our only responsibility and your only remedy under the above warranties. To obtain warranty service contact Customer Service by calling for the address of the repair location and the return shipping and handling fee. Enclose the Proof of Purchase. Include a letter, with your name, address, phone number, and description of the specific problem. Pack the product carefully to prevent damage in transit. Because of possible loss in transit, we recommend insuring the product with return receipt requested. THE FOREGOING IS THE SOLE WARRANTY PROVIDED BY OMRON IN CONNECTION WITH THIS PRODUCT, AND OMRON HEREBY DISCLAIMS ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IMPLIED WARRANTIES AND OTHER TERMS THAT MAY BE IMPOSED BY LAW, IF ANY, ARE LIMITED IN DURATION TO THE PERIOD OF THE ABOVE EXPRESS WARRANTY. OMRON SHALL NOT BE LIABLE FOR LOSS OF USE OR ANY OTHER SPECIAL, INCIDENTAL, CONSEQUENTIAL OR INDIRECT COSTS, EXPENSES OR DAMAGES. This warranty provides you with specific legal rights, and you may have other rights that vary by jurisdiction. Because of special local requirements, some of the above limitations and exclusions may not apply to you. 23
24 FCC STATEMENT NOTE: POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. The product generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If the product does cause harmful interference to radio or television reception, which can be determined by turning the product on and off, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the product and the receiver. Connect the product into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for Canada only) This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard entitled Digital Apparatus, ICES-003 of the Canadian Department of Communications. Cet appareil numérique respecte les limites de bruits radioeléctriques applicables aux appareils numériques de Clase B prescrites dans la norme sur le materiel brouilleur: Appareils Numériques, ICES-003 édictée par le minister des communications. Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. 24
25 Specifications Model: NE-C801 (NE-C801S-Z) Type: Compressor nebulizer Rating (AC adapter): V ~ 350mA, 50/60 Hz Rating (Compressor Nebulizer): 12V 0.8A Nebulization Rate: Approx. 0.3 ml/min (without cap) Particle Size: *MMAD approx. 3 μm (based on EN :2007) Medication Cup Capacity: 7 ml (cc) max. Appropriate Medication Quantities: 2 ml - 7 ml (cc) Operating Condition: Intermittent operation 20 min. ON/40 min. OFF Operating Temperature/ Humidity: +10 C to +40 C (+50 F to +104 F), 30% to 85% RH Storage Temperature/ Humidity/Air Pressure: 20 C to +60 C ( 4 F to +140 F), 10% to 95% RH 700 hpa to 1060 hpa Weight: Approx. 9.5 oz. (270 g) (compressor only) Dimensions: Approx. 5 5/8" (w) 2 7/8" (h) 3 7/8" (d) (142 mm 72 mm 98 mm) Contents: Compressor, Nebulizer Kit, Air Tube (PVC, 100 cm), Mouthpiece, Air Filters (Package of 5), AC Adapter, Storage Bag and Instruction Manual. Classification: Class II equipment, Type B applied part *MMAD = Mass Median Aerodynamic Diameter = Class II equipment = Type B applied part = No operation = Power on Read the instruction manual carefully NoteS: Subject to technical modification without prior notice. Please note that nebulization rate and particle size may vary with medication type used. Parts and accessories not approved for use do not meet these specifications. Do not use the device where it may be exposed to flammable gas. This unit conforms to EMC Standard IEC However, if it is used together with other medical devices or electrical equipment, they may influence the operations of one of devices. Please follow any instructions in the manuals and use all devices correctly. With respect to electric shock and mechanical hazards only in accordance with IEC
26 Technical Data Particle Specifications A series of aerosol performance tests were performed using an 8 stage cascade impactor at a sampling flow rate of 15 l/min equipped with a USP <601> induction port throat. Aerosol was sampled directly from the outlet. Three (3) device samples were tested with 3 runs each, for a total of 9 sample points per each drug. The specifications are listed below with intervals given for a 95% confidence level. Mean / Std. Dev Pulmicort (250μg/mL) Intal (10mg/mL) Salbutamol (5mg/mL) Total Delivered Dose (μg) ± ± ± Total Delivered Dose Fraction (%) 78.2% ± 3.3% 61.8% ± 3.1% 77.0% ± 2.5% Particle size (MMAD) μm 3.88 ± ± ± 0.28 Geometric Standard Deviation 1.93 ± ± ± 0.03 Respirable Fraction (0.5-5μm) 61.9% ± 4.0% 70.5% ± 1.3% 66.4% ± 1.6% Total Respirable Dose (μg between 0.5-5μm) ± ± ± Medication Captured on USP Throat ± ± ± Medication Captured on USP Throat Fraction (%) 3.4% ± 0.4% 2.0% ± 0.1% 1.8% ± 0.1% Medication Retained in Device ± ± ± Medication Retained in Device Fraction (%) 19.2% ± 1.9% 40% ± 2.2% 41.4% ± 5.2% Coarse Particle Fraction (%) (>4.7μm) 37.1% ± 2.9% 27.7% ± 1.5% 26.6% ± 2.3% Fine Particle Fraction (%) (<4.7μm) 59.6% ± 3.5% 70.2% ± 1.5% 71.6% ± 2.3% Ultra-Fine Particle Fraction (%) (<1.0μm) 3.5% ± 1.7% 8.9% ± 2.1% 16.9% ± 5.3% Note: Course particles (oro-pharyngeal deposition) and ultra-fine particles (exhaled) are not likely to deposit in the patient s airway and thus provide limited clinical benefit. 26
27 Guidance and Manufacturer's Declaration Important information regarding Electro Magnetic Compatibility (EMC) With the increased number of electronic devices such as PC s and mobile (cellular) telephones, medical devices in use may be susceptible to electromagnetic interference from other devices. Electromagnetic interference may result in incorrect operation of the medical device and create a potentially unsafe situation. Medical devices should also not interfere with other devices. In order to regulate the requirements for EMC (Electro Magnetic Compatibility) with the aim to prevent unsafe product situations, the IEC standard has been implemented. This standard defines the levels of immunity to electromagnetic interferences as well as maximum levels of electromagnetic emissions for medical devices. Medical devices manufactured by OMRON HEALTHCARE conform to this IEC standard for both immunity and emissions. Nevertheless, special precautions need to be observed: The use of accessories and cables other than those specified by OMRON, with the exception of cables sold by OMRON as replacement parts for internal components, may result in increased emission or decreased immunity of the device. The medical devices should not be used adjacent to or stacked with other equipment. In case adjacent or stacked use is necessary, the medical device should be observed to verify normal operation in the configuration in which it will be used. Do not use mobile (cellular) telephones and other devices, which generate strong electrical or electromagnetic fields, near the medical device. This may result in incorrect operation of the unit and create a potentially unsafe situation. Recommendation is to keep a minimum distance of 7 m. Verify correct operation of the device in case the distance is shorter. The NE-C801 is intended for use in the electromagnetic environment specified below. The customer or the user of the NE-C801 should assure that it is used in such environment. Electromagnetic emissions IEC Emissions test Compliance Electromagnetic environment - guidance The NE-C801 uses RF energy only for its RF emissions internal function. Therefore, its RF emissions Group 1 CISPR 11 are very low and are not likely to cause any interference in nearby electronic equipment. RF emissions CISPR 11 Harmonic emissions IEC Voltage fluctuations/ flicker emissions IEC Class B Class A Complies The NE-C801 is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. 27
28 Guidance and Manufacturer's Declaration Immunity test Electrostatic discharge (ESD) IEC Electrical fast transient/burst IEC Surge IEC Electromagnetic immunity IEC IEC Compliance Electromagnetic environment Test level level guidance Floor should be wood, concrete, or ±6 kv ±6 kv ceramic tile. If floors are covered contact contact with synthetic material, the relative ±8 kv air ±8 kv air humidity should be at least 30 %. ±2 kv for power supply lines ±1 kv for input/output lines ±1 kv line to line ±2 kv line to earth ±2 kv for power supply lines * 1) ±1 kv line to line ±2 kv line to earth Mains power quality should be that of a typical commercial and/or hospital environment. Mains power quality should be that of a typical commercial and/or hospital environment. Voltage dips, short interruptions and voltage variations on power supply IEC Power frequency (50/ 60 Hz) magnetic field IEC <5 % U T (>95 % dip in U T ) for 0.5 cycle 40 % U T (60 % dip in U T ) for 5 cycles 70 % U T (30 % dip in U T ) for 25 cycles <5 % U T (95 % dip in U T ) for 5 sec. <5 % U T (>95 % dip in U T ) for 0.5 cycle 40 % U T (60 % dip in U T ) for 5 cycles 70 % U T (30 % dip in U T ) for 25 cycles <5 % U T (95 % dip in U T ) for 5 sec. 3 A/m 3 A/m Mains power quality should be that of a typical commercial and/or hospital environment. If the user of the NE-C801 requires continued operation during power mains interruption, it is recommended that the NE-C801 be powered from an uninterruptible power supply or battery. Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment. Note: U T is the A.C. mains voltage prior to application of the test level. * 1) The test of input/output lines is not applicable since they are shorter than 3.0m. 28
29 Guidance and Manufacturer's Declaration Immunity test Conducted RF IEC Radiated RF IEC Electromagnetic immunity IEC IEC Compliance Electromagnetic environment Test level level guidance Portable and mobile RF communications equipment should be used no closer to any part of the NE-C801 including cables, than the recommended separation distance calculated from the equation appropriate to the frequency of the transmitter. Recommend separation distance d = 1.2 P d = 1.2 P 80 MHz to 800 MHz 3 V rms 3 V rms d = 2.3 P 800 MHz to 2.5 GHz 150 khz ~ where P is the maximum output 80 MHz power rating of the transmitter in watts (W) according to the 3 V/m 3 V/m transmitter manufacturer and d is the 80 MHz to recommended separation distance in 2.5 GHz meters (m). Field strengths from fixed RF transmitters as determined by an electromagnetic site survey,* 2) should be less than the compliance level in each frequency range.* 3) Interference may occur in the vicinity of equipment marked with he following symbol: Note1: At 80 MHz and 800 MHz, the higher frequency range applies. Note2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects, and people. * 2) Field strengths from fixed transmitters, such as base stations for radio (cellular/ cordless) telephones and land mobile radio, AM and FM radio broadcast, and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the NE-C801 is used exceeds the applicable RF compliance level above, the NE-C801 should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the NE-C801. * 3) Over the frequency range 150 khz to 80 MHz, field strengths should be less than 3 V/m. 29
30 Guidance and Manufacturer's Declaration Recommended separation distance between portable and mobile RF communications equipment and the NE-C801 The NE-C801 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customers or the users of the NE-C801 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the NE-C801 as recommended below, according to the maximum output power of the communications equipment. Separation distance according to frequency of transmitter in meter Output Power of Transmitter in Watt 150 khz to 80 MHz 80 khz to 800 MHz 800 MHz to 2.5GHz d = 1.2 P d = 1.2 P d = 2.3 P For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. Note: At 80MHz and 800MHz, the separation distance for the higher frequency range applies Note: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects, and people. EMC tests have included the AC adapter as included with the product. 30
31
32 Distributed by: Omron Healthcare, Inc West Field Court Lake Forest, IL U.S.A. toll-free: Made in China 2011 OMRON HEALTHCARE, INC.
NFC Communication Tray Model: HHX-IT3-Z
INSTRUCTION MANUAL NFC Communication Tray Model: HHX-IT3-Z ENGLISH CONTENTS Introduction...3 Important safety information...4 Know your unit...6 Transferring data to the PC...7 Care and maintenance...8
Dual Chamber Temporary External Pacemaker
5392 Dual Chamber Temporary External Pacemaker Electromagnetic Compatibility Declaration Caution: Federal law (USA) restricts this device to sale by or on the order of a physician. The following list includes
EverFlo. EverFlo Q EN, DE DSF 4/16/08
1053621 EN, DE DSF 4/16/08 EverFlo EverFlo Q English Table of Contents Symbol Key... 2 Abbreviations... 2 Chapter 1: Introduction... 3 Intended Use... 3 About Your EverFlo / EverFlo Q...3 Parts of Your
Automatic Wrist Blood Pressure Monitor with
Instruction Manual Automatic Wrist Blood Pressure Monitor with Model HEM-609 ENGLISH ESPAÑOL CONTENTS Before Using the Monitor Introduction...................................... 3 Important Safety Notes.............................
INSTRUCTION MANUAL. 7 series Blood Pressure Monitor with ComFit TM Cuff. Model BP760 ESPAÑOL ENGLISH
INSTRUCTION MANUAL 7 series Blood Pressure Monitor with ComFit TM Cuff Model BP760 ENGLISH ESPAÑOL TABLE OF CONTENTS Before Using the Monitor Introduction................................................4
SALTER AIRE Plus COMPRESSOR Model 8350 / 8352 / 8353. Instruction Manual. Page 1 of 9
SALTER AIRE Plus COMPRESSOR Model 8350 / 8352 / 8353 Instruction Manual Page 1 of 9 TABLE OF CONTENTS Introduction...3 Important Safeguards..3 System Components...5 Setup and Operation...5 Setup...5 Operation....6
EPM3. Phase Sequence and Motor Rotation Tester. Users Manual
EPM3 Phase Sequence and Motor Rotation Tester Users Manual 1 L1 L2 L3 2 3 A B C CAT 600V 3-PHASE TESTER 5 TEST M1 M2 BATT M3 EPM3 MOTOR ROTATION TESTER EPM3 MOTOR ROTATION DETERMINED WHILE FACING MOTOR
INSTRUCTION MANUAL. Ultra Premium Blood Pressure Monitor featuring ComFit TM Cuff. Model HEM-775
INSTRUCTION MANUAL Ultra Premium Blood Pressure Monitor featuring ComFit TM Cuff Model HEM-775 ENGLISH ESPAÑOL TABLE OF CONTENTS Before Using the Monitor Introduction..................................................4
INSTRUCTION MANUAL. 10 series Blood Pressure Monitor with ComFit TM Cuff. Model BP785CAN FRANÇAIS ENGLISH
INSTRUCTION MANUAL 10 series Blood Pressure Monitor with ComFit TM Cuff Model BP785CAN ENGLISH FRANÇAIS TABLE OF CONTENTS Before Using the Monitor Introduction..................................................4
INSTRUCTION MANUAL. 10 series Blood Pressure Monitor with ComFit TM Cuff. Model BP785 ESPAÑOL ENGLISH
INSTRUCTION MANUAL 10 series Blood Pressure Monitor with ComFit TM Cuff Model BP785 ENGLISH ESPAÑOL TABLE OF CONTENTS Before Using the Monitor Introduction................................................4
STRAPLESS HEART RATE MONITOR
INSTRUCTION MANUAL STRAPLESS HEART RATE MONITOR Model: HR-210 ENGLISH table TABLE of OF CONTENTS Before using the Monitor Introduction... 3 Important Safety Information...4 Operating the Device...4 Care
Caller-ID on your TV!
TM Caller-ID on your TV! User s Manual and Installation Guide Copyright 1998 NetMedia Inc., All rights reserved. Rev. 061898 Thank you for your purchase of Caller-TV! You are now ready to enjoy the convenience
Heated HumidifieR 1031849 HM 1/6/06
Heated HumidifieR M Series USER Manual 1031849 HM 1/6/06 Table of Contents Introduction...3 In This Manual...3 Intended Use...3 Warnings and Cautions...3 Warnings...3 Cautions...4 Symbol Key...5 System
Mini Power Bank and Charger
Mini Power Bank and Charger Owner s Manual Please read before using this equipment. Your charger is ETL listed to UL standards and meets all applicable FCC standards. WARNING: To reduce the risk of fire
Universal Laptop Charger
USER GUIDE Universal Laptop Charger NS-PWLC591/NS-PWLC591-C Before using your new product, please read these instructions to prevent any damage. NS-PWLC591/NS-PWLC591-C Insignia NS-PWLC591/ NS-PWLC591-C
INSTRUCTION MANUAL. Heart Rate Monitor. Model: HR-100C ST/SP SET MODE TIME
INSTRUCTION MANUAL Heart Rate Monitor Model: HR-100C ST/SP SET MODE TIME CONTENTS Before Using the Unit Introduction... 3 Important Safety Information... 4 Physical condition and workout... 7 Training
2013 VTech Printed in China 91-009656-000 US
Rechargeable Power Pack User s Manual 2013 VTech Printed in China 91-009656-000 US INTRODUCTION The Rechargeable Power Pack makes it easier than ever to keep the InnoTab 3 or InnoTab 3S charged and ready
User Guide Nokia Portable Wireless Charging Plate DC-50
User Guide Nokia Portable Wireless Charging Plate DC-50 Issue 1.1 EN User Guide Nokia Portable Wireless Charging Plate DC-50 Contents For your safety 3 About your accessory 4 Keys and parts 5 Top up your
INSTRUCTION MANUAL. Pocket Pedometer. Model HJ-112
INSTRUCTION MANUAL Pocket Pedometer Model HJ-112 CONTENTS Before Using the Unit Introduction...3 Important Safety Information...4 Know Your Unit...6 Main Unit...6 Components...7 Aerobic Step Function...8
The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.
i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive
3 WATT LED SPOTLIGHT Model No. SLM - 3801
3 WATT LED SPOTLIGHT Model No. SLM - 3801 OWNER'S MANUAL Customer Service Tel: 1-800-268-3319 Superex Canada Ltd, Toronto,M2H 3B8 Made in China Table of Contents A). Important Safety Instructions B). Charging
Conference Phone UserÕs Manual. Part No. 54-2070-01R1 Printed in Korea. 2002 Bogen Communications, Inc.
Part No. 54-2070-01R1 Printed in Korea. 2002 Bogen Communications, Inc. UserÕs Manual Notice Every effort was made to ensure that the information in this guide was complete and accurate at the time of
User and Installation Guide
Connect the AC adapter with the amplifier BEFORE plugging the AC adapter into an outlet to avoid spark generation! User and Installation Guide BlueFIDELITYTM Bluetooth Audio Amplifier Model 300 Contents
user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4
user s manual model #: SPB3200 Charger for Samsung Galaxy S 4 What s Included Unpack the battery case and make sure all accessories are put aside so they will not be lost. hello. USB to Micro USB Cable
MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference
MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725 Read this manual thoroughly before using and save it for future reference Purchase MAP capsules at Harvey Norman stores nationwide
Power Over Ethernet Adapters POE101
Power Over Ethernet Adapters POE101 Installation Guide Introduction NETGEAR POE101 Power over Ethernet adapters are designed to supply operational power to devices through an Ethernet cable. These adapters
INSTALLATION GUIDE. AXIS T8133 Midspan 30W
INSTALLATION GUIDE AXIS T8133 Midspan 30W ENGLISH Liability Every care has been taken in the preparation of this document. Please inform your local Axis office of any inaccuracies or omissions. Axis Communications
Wireless Indoor/ Outdoor Thermometer
Wireless Indoor/ Outdoor Thermometer Owner s Manual Please read before using this equipment. ˆ Contents FCC Information... 3 FCC Declaration of Conformity... 5 Preparation... 5 Installing Batteries...
Instruction Manual. Fat Loss MONITOR with Scale. Model HBF-400
Instruction Manual Fat Loss MONITOR with Scale Model HBF-400 TABLE OF CONTENTS Before Using the Monitor Introduction 3 Important Safety Notes 4 Useful Information What is Body Fat Percentage? 5 Principles
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
Portable Multiband Radio (120-0456A) Features Faxback Doc. # 56400
(120-0456A) Features Faxback Doc. # 56400 Your RadioShack Portable Multiband Radio is an all-in-one radio system designed to provide high-quality sound. the multi-band tuner lets you listen to the radio,
User Manual. CFG253 3 MHz Function Generator 070-8362-04
User Manual CFG253 3 MHz Function Generator 070-8362-04 Copyright Tektronix, Inc. 1993. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information
12-Volt 10-Amp Regulated Power Supply
22-506.fm Page 1 Friday, August 6, 1999 12:55 PM Cat. No. 22-506 OWNER S MANUAL Please read before using this equipment. 12-Volt 10-Amp Regulated Power Supply 22-506.fm Page 2 Friday, August 6, 1999 12:55
CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN
BeoLab 7-6 Guide CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified
AM/FM Emergency Weather Radio/Light With Hand Crank Back-Up Power
VEC173 ONE YEAR LIMITED WARRANTY PROGRAM This limited warranty program is the only one that applies to this product, and it sets forth all the responsibilities of Vector Manufacturing, regarding this product.
User Guide Microsoft Screen Sharing for Lumia Phones (HD-10)
User Guide Microsoft Screen Sharing for Lumia Phones (HD-10) Issue 1.1 EN-US User Guide Microsoft Screen Sharing for Lumia Phones (HD-10) Contents Safety 3 About your accessory 4 Keys and parts 5 Connect
INSTRUCTION MANUAL. Pedometer. Model HJ-112
INSTRUCTION MANUAL Pedometer Model HJ-112 Thank you for purchasing the OMRON Pedometer. Please read this Instruction Manual before using this unit to ensure safe and correct use. Please keep this Instruction
How To Use A Cdm250 Digital Multimeter
User Manual CDM250 Digital Multimeter 070-6736-03 Copyright Tektronix, Inc. 1987. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this
MB169B+ USB Monitor. User Guide
MB169B+ USB Monitor User Guide Table of contents Notices... iii Safety information... iv Care & cleaning... v Takeback services... vi 1.1 Welcome!... 1-1 1.2 Package contents... 1-1 1.3 System requirement...
BeoLab 7-1 BeoLab 7-2. Guide
BeoLab 7-1 BeoLab 7-2 Guide CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified service personnel. WARNING: To prevent
7 High-Resolution Digital Photo Frame
TM 16-1003 User s Guide 7 High-Resolution Digital Photo Frame One demo photo included, as illustrated Please read this user s guide before using your new photo frame. Package contents Photo Frame AC Adapter
Mini Speaker. Printed in China Part No. 480-919-P Version D. CWA BT300 Product Information Guide
Mini Speaker Printed in China Part No. 480-919-P Version D CWA BT300 Product Information Guide IMPORTANT To get the full capability of your new Cobra Airwave Mini, please read this manual. It's more than
DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL
DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL Service Information If service or parts are required, contact the nearest Norcold Service Center. To find an authorized Norcold Service Center
Installation Guide. Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit. Issue: 022808 PN: 883884-07L Rev. A
Installation Guide Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit Issue: 022808 PN: 883884-07L Rev. A ii Copyright Notice 2008, Wyse Technology Inc. All rights reserved. This manual and the
RC930 Manual 6/10/99 1:23 PM Page 1. Wireless Modem Jack
RC930 Manual 6/10/99 1:23 PM Page 1 Wireless Modem Jack Table of Contents Safety Precautions...1 Important Notes...4 Getting Started...5 System Installation...5 Connecting to Computer...6 Trouble Shooting...7
BOSE. Link AL8 HOMEWIDE WIRELESS AUDIO LINK
BOSE Link AL8 HOMEWIDE WIRELESS AUDIO LINK Français English SAFETY INFORMATION Please read this owner s guide Please take the time to follow the instructions in this owner s guide carefully. It will help
#0086. www.medrx-usa.com
INSTALLATION MANUAL Contents Getting to Know Your AVANT REM Speech+... 3 Software Installation... 4 Driver Installation Windows 7... 7 Driver Installation Windows XP... 11 EMC Precautions... 14 Safety
EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System
EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System Instruction Manual DELUXE AND MINI RECEIVER KIT (RX) INSTRUCTIONS " WARNING THIS MANUAL MUST BE READ CAREFULLY BY ALL INDIVIDUALS
User Guide Microsoft Screen Sharing for Lumia Phones (HD-10)
User Guide Microsoft Screen Sharing for Lumia Phones (HD-10) Issue 1.1 EN User Guide Microsoft Screen Sharing for Lumia Phones (HD-10) Contents Safety 3 About your accessory 4 Keys and parts 5 Connect
Installation & Operation Manual
GET CONNECTED Installation & Operation Manual DEVICE INTEGRATION AND CHARGING KIT TranzIt USB IS32 Note to Readers, The information contained within the following documentation is subject to change without
USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model # 900172
Model # 900172: Page 1 USER MANUAL Bottom Loading Bottled Water Dispenser Model # 900172 TO REDUCE THE RISK OF INJURY AND PROPERTY DAMAGE, USER MUST READ THIS MANUAL BEFORE ASSEMBLING, INSTALLING & OPERATING
PROGRAMMER INSTALLATION INSTRUCTIONS
PROGRAMMER INSTALLATION INSTRUCTIONS TABLE OF CONTENTS Description 4 Installation 4 Operation 5 Safety Precautions 6 Regulatory & Service Information 6 Important Safety and Usage Information 7 Regulatory
READ FIRST! Universal Car/Air Adapter User Manual
AutoAir Manual 1/9/03 2:03 PM Page 1 READ FIRST! Universal Car/Air Adapter User Manual Congratulations! Your new Kensington Universal Car/Air Adapter is a highly efficient Universal Car/Air Adapter for
Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!
BeoLab 6002 Guide WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. Do not expose this equip ment to dripping or splashing and ensure that no objects
Zolt Laptop Charger Plus User Guide
Zolt Laptop Charger Plus User Guide 70W Universal Laptop and Mobile Device Charger 1 Meet your Zolt Laptop Charger Plus The Zolt Laptop Charger Plus is a compact, lightweight, multi-device charger that
Panasonic. Proprietary Telephone for Electronic Modular Switching System MODEL NO. KX-17030. Illustrated Model: White 1
Panasonic Proprietary Telephone for Electronic Modular Switching System MODEL NO. KX-17030 Illustrated Model: White 1 KX-T7030 is compatible with all of the Panasonic Electronic Modular Switching Systems
USB/RS485 converter cable, complete
USB/RS485 converter cable, complete Instructions for use Contents Deutsch 1 Intended use 3 2 Safety 3 2.1 Safety information... 3 2.2 General information... 3 3 Description 5 3.1 Overview... 5 3.2 Connection
User s Manual. 2010 VTECH Printed in China 91-002395-025-000
User s Manual 2010 VTECH Printed in China 91-002395-025-000 INTRODUCTION When Skipper overhears King Julien insulting the penguins, a contest is proposed. Who is more popular, the penguins or the lemurs?
Radiometrics Guide to FCC & Canada Compliance. for Unintentional Radiators
Radiometrics Guide to FCC & Canada Compliance for Unintentional Radiators Since 1934, the FCC has had the authority to regulate the electromagnetic emissions from electronic devices. Since October 1, 1983,
Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver.
Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver. OWNER'S MANUAL VR36A XC18A XM13A MODEL VK69A (INCLUDES XC18A CAMERA, XM13A
www.iconnectivity.com
www.iconnectivity.com USER GUIDE WARRANTY INFORMATION iconnectivity warrants to the original purchaser that this unit is free of defects in materials and workmanship under normal use and maintenance for
W O R L D C L A S S H I F I
W O R L D C L A S S H I F I O W N E R S M A N U A L Accessories: NAPSC, i-supply, Headline, Stageline IMPORTANT In order to comply with current European safety regulations it is essential that the Naim
EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System
EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System Instruction Manual DELUXE AND MINI RECEIVER KIT (RX) INSTRUCTIONS " WARNING THIS MANUAL MUST BE READ CAREFULLY BY ALL INDIVIDUALS
Broadband Telecommunications Drop Amplifier
INSTALL SHEET BDA Broadband Telecommunications Drop Amplifier Introduction The Broadband Telecommunications Drop Amplifier (BDA) is a two-way, 1 GHz amplifier designed for customer-premise amplification
CPAP System This CPAP system is intended for the treatment of adult obstructive Sleep Apnea only. NOTE: The C-Flex mark is used under license.
Home Care Provider Setup Instructions Always use these instructions along with the User Manual when assembling or adjusting this equipment. For clinical systems, refer to the setup guide entitled Respironics
System One Heated Humidifier USER MANUAL
System One Heated Humidifier USER MANUAL 2009 Respironics Inc. and its affiliates. All rights reserved. Table of Contents Intended Use... 2 Warnings... 2 Cautions... 2 Symbol Key... 2 System Features and
LF-IRX. Limited Warranty LF-IRX. Remote Control Extender OWNER S MANUAL
Limited Warranty OWNER S MANUAL Audiovox Corporation (Audiovox) warrants this product against defects in materials or workmanship for one (1) year from the date of purchase. During this period, this product
Model 70A00-1. GSM Cellular Communications Center
Home Automation, Inc. Model 70A00-1 GSM Cellular Communications Center Operation Manual Document Number 70I00-1 Rev A August, 2009 Contents Description... 1 Use with security systems...1 Everyday use...2
Wireless Keyboard and Optical Mouse Bundle
Wireless Keyboard and Optical Mouse Bundle Enjoy the freedom of wireless optical precision User Manual F8E832-BNDL TABLE OF CONTENTS Introduction....................................1 Compatible Equipment............................2
When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.
BeoLab 11 Guide WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. Do not expose this equip ment to dripping or splashing and ensure that no objects
Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10
Business Audio System: Music & Messaging MP3 Player by Grace Digital Audio User Guide Model No. GDI-USBM10 User Guide Contents Introduction 2 Safety & General Use Information 2 Features 3 Set Up & Operation
Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL
Electric Kettle Model: SK-1717 INSTRUCTIONS MANUAL Thank you for your purchase. Please read this Instruction Manual thoroughly before use and keep in a safe place for future reference. READ ALL INSTRUCTIONS
Manual Ranging MultiMeter
Owner s Manual Manual Ranging MultiMeter Model 82345 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.! Safety! Operation! Maintenance!
WARNING: To prevent fire or electric shock, do not expose this appliance to rain or moisture.
BeoVision 4 1 Guide CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified service personnel. WARNING: To prevent fire
Wireless Optical Mouse
Wireless Optical Mouse User s Manual Model PD950P FCC STATEMENT PD950P This device complies with part 15 of FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause
CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN
BeoLab 4 Guide CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified service
Product Overview. Product Interface
mobile speaker Product Overview Thank you for purchasing the bēm wireless Mobile Speaker. Our speaker will bring you a new found freedom from wires while delivering an incredible sound. The Mobile Speaker
Gateway Port Replicator User Guide
Gateway Port Replicator User Guide Using the Port Replicator Identifying features Connecting and disconnecting the port replicator 1 Using the Port Replicator Top Power button Component Icon Description
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
Power Max Level 2 Charging Station en Installation and Operating Instructions This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
4.3-inch Back-Up Camera
TM 4.-inch Back-Up Camera Model No.: PKC0BU4 Owner s Manual and Warranty Information Read these instructions completely before using this product. Retain this Owner s Manual for future reference. INTRODUCTION
HP SuperSpeed USB 3.0 PCIe x1 Card. User Guide
HP SuperSpeed USB 3.0 PCIe x1 Card User Guide Copyright 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, and Windows
Bottom Loading Water Dispenser
Bottom Loading Water Dispenser Model # 601000 TO REDUCE THE RISK OF INJURY AND PROPERTY DAMAGE, USER MUST READ THIS MANUAL BEFORE ASSEMBLING, INSTALLING & OPERATING DISPENSER. SAVE THIS MANUAL FOR FUTURE
AutoRanging Digital MultiMeter
Owner's Manual AutoRanging Digital MultiMeter Model No. 82139 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance
Intelli-Time Alarm Clock model 13027
Instruction Manual Intelli-Time Alarm Clock model 13027 CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2 Features & Benefits... 3 Clock Setup... 4 Intelli-Time Clock...
User manual. Your best protection against theft and loss. (Android) Made for
User manual Made for Your best protection against theft and loss (Android) Warranty SCOPE OF THE WARRANTY Subject to legal provisions, the responsibility of SECU4 under this warranty is limited to the
Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC
Portable Evaporative Air Cooler OWNER S MANUAL Read and save these instructions before use Model: CL30XC Power rating: 250 Watts Voltage rating: 230 Volt, 50Hz Made in P.R.C. QUICK START GUIDE Fill with
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
User Guide for the Wireless Headset (HS-11W) 9235346 Issue 1
User Guide for the Wireless Headset (HS-11W) 9235346 Issue 1 DECLARATION OF CONFORMITY We, NOKIA CORPORATION declare under our sole responsibility that the product HS-11W is in conformity with the provisions
OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER
OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER P110 Your battery charger has been engineered and manufactured to Ryobi s high standard for dependability, ease of operation, and operator safety. When properly
BTX180 Wireless Bluetooth Speaker
BTX180 Wireless Bluetooth Speaker User Manual 2012 Kinivo LLC. All rights reserved. Kinivo is a trademark of Kinivo LLC. Bluetooth word mark and the Bluetooth logo are registered trademarks of Bluetooth
Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7
Register online today for a chance to win a FREE Tripp Lite product! www.tripplite.com/warranty Owner s Manual Internet Office & BC Personal UPS Systems Not suitable for mobile applications. Important
4-Port Switch. 10/100/1000 Mbps Gigabit Ethernet GS104. Installation Guide
4-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS104 Installation Guide 4500 Great America Parkway Santa Clara, CA 95054 USA Phone: 1-888-NETGEAR E-mail: [email protected] www.netgear.com Technical
ReadyNet Easy Jack 2 Voice/Data and Data Only Owner s Manual PX-211d and PX-211v
ReadyNet Easy Jack 2 Voice/Data and Data Only Owner s Manual PX-211d and PX-211v Phonex Broadband Corporation dba ReadyNet 6952 High Tech Drive Midvale, Utah 84047 801.566.0100 Phone 801.566.0880 Fax www.readynetsolutions.com
100 Series Maxi Internal Filters. Instruction Manual
100 Series Maxi Internal Filters Instruction Manual Important Safeguards This appliance is not intended for use by children or infirm persons without supervision. Young children should be supervised to
User Guide FOR FACE AND BODY SONIC SKIN CLEANSING. Become a Clarisonic Preferred Customer. Four Speeds + Body Setting. Three-Year Warranty
FOR FACE AND BODY User Guide Four Speeds + Body Setting Three-Year Warranty Adjustable T-Timer Charging Cradle Body Brush Head SONIC SKIN CLEANSING Beautiful skin begins with cleaner skin. Cleaner skin
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
Operating Instructions
Operating Instructions Vision 5L Digital Holter Recorder Document Number: 010-1646-00 Revision: H Bothell, Washington 98021-8969 (608)-764-1919 Caution: U.S. Federal law restricts this device to sale by
Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.
OFF COOL 0 3 2 1 OFF Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use ON SPEED ON SWING OWNER S MANUAL Read and save these instructions before use Model: CO60PM Power rating: 220 Watts
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
5-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS105
5-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS105 Installation Guide Introduction The NETGEAR 5-Port Gigabit Ethernet Switch Model GS105 provides you with a low-cost, reliable, high-performance switch
