Multijacketed Tubing, Single-Jacketed Tubing, and Insulated Tubing

Size: px
Start display at page:

Download "Multijacketed Tubing, Single-Jacketed Tubing, and Insulated Tubing"

Transcription

1 Multijacketed Tubing, Single-Jacketed Tubing, Insulated Tubing Features 1/4 to 6 to 12 tubing sizes available in 316/316L stainless steel copper Seamless welded tubing available in stainless steel Thermoplastic polyurethane (TPU) PVC jackets help protect tubing from external corrosion abrasion Fibrous glass insulation reduces heat loss helps protect personnel

2 2 Multijacketed Tubing, Jacketed Tubing Insulated Tubing Multijacketed Tubing Swagelok multijacketed tubing provides protection against galvanic atmospheric corrosion protects the tubing against wear abrasion. In addition, it reduces costs by enabling installation of up to four tubes at once. Features 316/316L stainless steel instrumentation tubing 1/4 to 6 to 12 tubing sizes Low-temperature, UV-resistant thermoplastic polyurethane (TPU) for both individual tube jackets outer jacket Positive identification of individual tubes along entire length jacket marking stard; see Stard Marking, below. Individual tubes are marked for positive identification along their entire length. Materials of Construction Component Tubing Jackets Material/Grade 316/316L / ASTM A269, A213➀ Thermoplastic polyurethane Stiffening plate Aluminum 3- Inner wrap, outer wrap Foam wrap Polyester film Closed cell, EPDM foam rubber ➀ wall thickness, not minimum wall thickness. Seamless metric sizes also meet DIN test 1 class material 1.41/1.44. Stard Marking Stard marking includes model, size, materials, specifications, temperature rating, batch number for traceability. Individual Example: Swagelok Model MJT /316L SMLS ASTM A269 TPU Jacket Maximum 2/1 Caution May Be Hot Batch Outer Jacket Example: ft Swagelok Model MJT Two /316L SMLS ASTM A269 TPU Jacket Maximum 2/1 Caution May Be Hot Batch Technical Data Fractional Tubing Data Max Process For additional information, see Swagelok Tubing Data, MS-1-7. Pressure Rating at to psig 1/ /8.35 service; ➀ 2.49 installation 29 ➀ Not recoended for use with tube fittings in gas service. Metric Max Process Min Bend Radius Support Centers ft Seamless Welded Horiz Vert Pressure Rating at 28 to 37 bar Min Bend Radius cm Support Centers m Seamless Welded Horiz Vert service; installation 1 For jacket properties information, see page 5. Dimensions Dimensions are for reference only are subject to change. W H H W, Width Height Weight Max Bulk Length Dimensions lb/ft ft 4 1/ / Dimensions kg/m m

3 Single-Jacketed Tubing Swagelok single-jacketed tubing helps provide increased protection against galvanic atmospheric corrosion. In addition, it helps protect the tubing against wear abrasion. Features 316/316L stainless steel copper instrumentation tubing 1/4 to 6 to 12 tubing sizes Low-temperature, UV-resistant PVC jacket stard; optional thermoplastic polyurethane (TPU) jacket available for higher-temperature service Jacket marking available; see Optional Jacket Marking, below. Technical Data Fractional Max Process Multijacketed Tubing, Jacketed Tubing Insulated Tubing 3 Pressure Rating at Min Support Max Bulk Length to Bend Centers Jacket ± % psig Radius ft Weight ft Seamless Welded Horiz Vert lb/ft Seamless Welded Stainless Steel (ASTM A269, A213➀, TP 316/316L) 1/4.35 2, PVC, /8.35 jacket; service; ➁ 2, TPU, 2.25 jacket installation Copper (ASTM B68, B68M, B75, UNS 12) 1/4. 2, PVC, /8.32 jacket; service; ➁ 2, TPU,.26 jacket installation ➀ wall thickness, not minimum wall thickness. ➁ Not recoended for use with tube fittings in gas service. Metric Max Process Pressure Rating at Min Support Max Bulk Length 28 to 37 Bend Centers Jacket ± % bar Radius m Weight m Seamless Welded cm Horiz Vert kg/m Seamless Welded Stainless Steel (ASTM A269, A213➀, TP 316/316L) 6 4, PVC 34, jacket; service; 121, TPU 23, jacket installation Copper (ASTM B68, B68M, B75, UNS 12) , PVC 34, jacket; service; , TPU 23, 12 1.➁ jacket installation ➀ wall thickness, not minimum wall thickness. Seamless metric sizes also meet DIN test 1 class material 1.41/1.44. ➁ Not recoended for use with tube fittings in gas service. Optional Jacket Marking Optional marking includes model, size, materials, specifications, temperature rating, batch number for traceability. Example: ft Swagelok Model JT /316L SMLS ASTM A269 PVC Jacket Maximum 2/4 Caution May Be Hot Batch Tubing Data For additional information, see Swagelok Tubing Data, MS-1-7. For jacket properties information, see page 5.

4 4 Multijacketed Tubing, Jacketed Tubing Insulated Tubing Insulated Tubing Swagelok insulated tubing is designed for use in applications such as steam supply, condensate return, gas liquid transport lines, where weatherproofing energy conservation are important. Swagelok insulated tubing helps protect personnel from hot process steam lines, reduces heat loss, offers a cost-effective alternative to field-installed insulation of small-diameter tubing systems. Features 316/316L stainless steel copper instrumentation tubing 1/4 to 6 to 12 tubing sizes Low-temperature, UV-resistant PVC jacket stard; optional TPU jacket available Absorption-resistant fibrous glass insulation Insulation contains less than ppm of water-soluble chlorides Jacket marking stard; see Stard Jacket Marking, below. Technical Data Fractional Max Process Seal insulation ends to prevent contamination of the insulation. Pressure Rating at Min Support Max Bulk Length Bend Centers Jacket ± % psig Radius ft Weight ft Seamless Welded Horiz Vert lb/ft Seamless Welded Stainless Steel (ASTM A269, A213➀, TP 316/316L) 1/4.35, /8.35 service; ➂ ➁, installation Copper (ASTM B68, B68M, B75, UNS 12) 1/4., /8.32 service; ➂ ➁,.43 installation ➀ wall thickness, not minimum wall thickness. ➁ Not recoended for use with tube fittings in gas service. ➂ The maximum jacket surface temperature is 1 with a process temperature of, an ambient temperature of, a wind of mph. Metric Max Process Pressure Rating at Min Support Max Bulk Length 4 Bend Centers Jacket ± % bar Radius m Weight m Seamless Welded cm Horiz Vert kg/m Seamless Welded Stainless Steel (ASTM A269, A213➀, TP 316/316L) 6 34, service; 1. 4➁ 23, installation Copper (ASTM B68, B68M, B75, UNS 12) , service; 1. 4➁ , 12 1.➂ installation ➀ wall thickness, not minimum wall thickness. Seamless metric sizes also meet DIN test 1 class material 1.41/1.44. ➁ The maximum jacket surface temperature is with a process temperature of 4, an ambient temperature of 26, a wind of 16 km/h. ➂ Not recoended for use with tube fittings in gas service. Stard Jacket Marking Stard marking includes length, ordering number, temperature rating, batch number for traceability. Example: ft Swagelok SS ST4 S 35 U /4 Continuous Batch Tubing Data For additional information, see Swagelok Tubing Data, MS-1-7. For jacket properties information, see page 5.

5 1 Insulated Tubing Heat Loss Multijacketed Tubing, Jacketed Tubing Insulated Tubing 5 The information presented represents typical performance data for low-temperature PVC TPU jackets for the conditions given. Actual results may vary with the conditions of installation. Heat loss calculated with 25 mph ( km/h) wind. 1/4 6 Tubing 12 Tubing Heat Loss, Btu/h ft 9 Ambient, Heat Loss, Kcal/h m Heat Loss, Btu/h ft 9 USA Ambient, Heat Loss, Kcal/h m US 1 1 Ambient, Ambient, 3/8 Tubing Heat Loss, Btu/h ft 9 9 Ambient, 1 Ambient, Heat Loss, Kcal/h m Legend 9 psig (13.7 bar) steam 388 (197) 125 psig (8.6 bar) steam 353 (178) psig (3.4 bar) steam 299 (148) 15 psig (1. bar) steam 2 (121) JAPAN USA J Jacket Properties Jacket Properties Low- PVC Thermoplastic Polyurethane (TPU) Tensile strength 2 psi (151 bar) 9 psi (261 bar) Elongation 3 % % Hardness, Shore A JAPAN Maximum temperature 2 (4) EURO 2 (121) Minimum installation temperature ( 23) ( ) Minimum service temperature ( 34) 67 ( 55) Halogenated (chlorides) Yes No Water absorption. % 1.2 to 1.4 % 24 rating in accordance with V2 in accordance with Flame resistance ASTM D2863 UL94 7 h in accordance with h in accordance with UV resistance UL-1581 QUV aging test 9 EU

6 6 Multijacketed Tubing, Jacketed Tubing Insulated Tubing Ordering Information Multijacketed Tubing Build a multijacketed tubing ordering number by combining the designators in the sequence shown below. A B C D E F S S - M J T S F 1 A Material SS = 316/316L stainless steel B Model MJT = Multijacketed C Number of 2 = 2 tubes of same size 3 = 3 tubes of same size 4 = 4 tubes of same size D Size: Seamless Stainless Steel, Fractional 4-S-35 = 1/ S-35 = 3/ S-35 =.35 8-S-49 =.49 Seamless Stainless Steel, Metric 6M-S-1.M = 6 1. M-S-1.M = 1. 12M-S-1.M = Welded Stainless Steel, Fractional 4-W-35 = 1/ W-35 = 3/ W-35 =.35 8-W-49 =.49 Welded Stainless Steel, Metric 6M-W-1.M = 6 1. M-W-1.M = 1. 12M-W-1.M = E Package Length Unit of Measure F = Feet M = Meters F Package Length, Tolerance Specify a bulk length up to the maximum bulk length shown on page 2. 1 = Continuous length, ± 5 % (contains one piece) 2 = Exact length, ±.5 % (may contain multiple pieces) 3 = Continuous, exact length, ±.5 % (contains one piece) 4 = Stard length, ± 5 % (may contain multiple pieces) Single-Jacketed Insulated Tubing Build a single-jacketed or insulated tubing ordering number by combining the designators in the sequence shown below. A B C D E S S - S T 4 - S U A Material CU = Copper SS = 316/316L stainless steel B Model JT = Single-jacketed ST = Insulated C Size: Copper, Fractional 4- = 1/ = 3/ = =.49 Copper, Metric 6M-1.M = 6 1. M-1.M = 1. 12M-1.M = M-1.5M = Seamless Stainless Steel, Fractional 4-S-35 = 1/ S-35 = 3/ S-35 =.35 Seamless Stainless Steel, Metric 6M-S-1.M = 6 1. M-S-1.M = 1. 12M-S-1.M = Welded Stainless Steel, Fractional 4-W-35 = 1/ W-35 = 3/ W-35 =.35 Welded Stainless Steel, Metric 6M-W-1.M = 6 1. M-W-1.M = 1. 12M-W-1.M = D Package Length Fractional = ft (.5 m) 2 = 2 ft (76.2 m) = ft (152 m) xxxx = Bulk length➀ Metric M = m (98.4 ft) 75M = 75 m (246 ft) 1M = 1 m (492 ft) xxxx = Bulk length➀ ➀ See pages 3 4 for the maximum bulk length of tubing. E Options For multiple options, add designators in alphabetical order. M = Jacket marking, 6 ft (2 m) intervals (model JT only; see page 3 for details) U = TPU jacket

7 Multijacketed Tubing, Jacketed Tubing Insulated Tubing 7 Options Jacket Colors The stard jacket is black. For other colors, contact your authorized Swagelok sales service representative. Tubing Material Size Other materials sizes are available. Contact your authorized Swagelok representative. Accessories Heat-Shrink Adhesive-Lined Sleeves Used to protect bare tubing straight fitting connections to jacketed insulated tubing, these sleeves contain a heat-activated adhesive to provide a watertight seal to the protected area. Sleeve Description.75 (19. ) dia, shrinks to. (5.1 ) dia 1. (25.4 ) dia, shrinks to. (7.6 ) dia 2. (.8 ) dia, shrinks to.75 (19. ) dia 3. (76.2 ) dia, shrinks to 1. (25.4 ) dia Ordering Number MS-HSB-S75 MS-HSB-S MS-HSB-S MS-HSB-S Multijacketed Tubing Heat-Shrink Sleeve Selection Heat Shrink Boot Ordering Number 1/4 MS-HSB-S MS-HSB-S MS-HSB-S 3/8 MS-HSB-S MS-HSB-S MS-HSB-S MS-HSB-S MS-HSB-S MS-HSB-S 6 MS-HSB-S MS-HSB-S MS-HSB-S 8 MS-HSB-S MS-HSB-S MS-HSB-S MS-HSB-S MS-HSB-S MS-HSB-S 12 MS-HSB-S MS-HSB-S MS-HSB-S Silicone Sealing Tape Silicone sealing tape is used in conjunction with heat-shrink sleeves to seal the ends of jacketed insulated tubing where the jacket material needs to be removed to assemble a fitting. Each roll is ft (3. m) long 1.5 (38.1 ) wide. Ordering number: MS-SR-B Silicone Sealant This silicone RTV sealant is used in conjunction with heatshrink sleeves to seal ends of jacketed insulated tubing from moisture, it offers excellent resistance to weather, oil, many chemicals. One tube will seal approximately ends; each kit contains 8 tubes. Service : to ( 51 to 4) Cure Time: approximately 24 h at 77 (25) % relative humidity Ordering number: MS-RTV-SEAL-KIT Jacket Patch Kit The jacket patch kit can be used to seal a splice in tubing or to repair any incidental field damage to insulation jacket. Each kit contains thermal insulation, fiberglass tape, self-sealing patches. Ordering number: MS-JP-KIT Weatherproof Strip Insulation Weatherproof strip insulation provides an effective method of temporarily insulating components. The jacketed insulation is universal easy to install. It is approximately 4 (2 ) wide (12.7 ) thick is available in stard lengths of,, ft (3., 9.1, 15.2 m) packages. Insulation Item Ordering Number ft (3. m) insulation strip MS-SI- ft (9.1 m) insulation strip MS-SI- ft (15.2 m) insulation strip MS-SI- 25 insulation tie straps MS-SITS-KIT Heat-Shrink End-Seal Boots (Insulated Tubing) Made of thermally stabilized, modified polyolefin, these heat-shrinkable boots provide a weatherproof end seal for all sizes of insulated tubing protect against moisture ingress. Each kit contains end-seal boots. Ordering number: MS-HSB-KIT Caps (Insulated Tubing) Protective end caps temporarily seal insulated tubing ends insulatation during storage installation. Each kit contains caps. 1/4 3/8 Ordering Number 6 MS-46-CAP-KIT 12 MS-8-CAP-KIT

8 Accessories Mounting Clips Stainless steel mounting clips secure jacketed tubing to brackets or tubing trays. Clips consist of a 6 bolt nut two 6 washers. When using strut-type mounting brackets, also order strut nuts, below. Multijacketed 1/4 6 3/8 8, 12 Strut Nuts Number of Strut nuts are used when securing jacketed tubing to strut-type mounting brackets Ordering number: MS-M65 Related Products Ordering Number 2 MS-K42 3 MS-K43 4 MS-K44 2 MS-K62 3 MS-K63 4 MS-K64 2 MS-K82 3 MS-K83 4 MS-K84 Jacketed Connector (JTC) For use with 1/4, 3/8, jacketed tubing with up to 1/16 nominal jacket thickness Available in all stard tube fitting configurations Provides a leak-tight seal on the tubing jacket preventing environmental ingress Single-Jacketed Ordering Number 1/4 6 MS-K41 3/8 8 MS-K61, 12 MS-K81 See the Swagelok Jacketed Connector (JTC) catalog, MS Tools Breakout Bending Tools The tube breakout bender is used with multijacketed tubing to separate bend individual tubes up to or 12 outside diameter. The bending tools are used to bend 2-, 3-, or 4-tube multijacketed tubing or insulated tubing bundles with up to or 12 outside diameter tubes. Description breakout bender,➀ 1.75 (44.4 ) radius Bending tool,➁ 8 ( cm) radius Bending tool,➁ 12 ( cm) radius Ordering Number MS-BT1 MS-BBT MS-BBT-12 ➀ Requires square drive ratchet, not included. ➁ Requires 3/4 NPT threaded hle, not included. Combination Spool St/Bundle Straightener This tool safely pays out straightens spooled coils of jacketed or insulated tubing. It accepts stard 46 (117 cm) spool diameters up to 36 (91 cm) wide. Dimensions: H by 47 W by 49 D (127 H by 119 by 124 D cm) Ordering number: MS ST4636 Five-Roll Straightener The straightener can be mounted to the spool st for use with single, coiled jacketed or nonjacketed tubing up to or 12 outside diameter. Case included. Case dimensions: 15.5 H by 19.8 W by 7.25 D ( H by.2 W by 18.4 D cm) Ordering number: MS TST12 Breakout Bender Safe Product Selection When selecting a product, the total system design must be considered to ensure safe, trouble-free performance. Function, material compatibility, adequate ratings, proper installation, operation, maintenance are the responsibilities of the system designer user. Warranty Information Swagelok products are backed by The Swagelok Limited Lifetime Warranty. For a copy, visit swagelok.com or contact your authorized Swagelok representative. Swagelok TM Swagelok Company 3 15 Swagelok Company Printed in U.S.A., AGS May 15, R8 MS-2-188

RTB Tubing Bundles Installation Guide Heating solutions for instrument and small-diameter process lines

RTB Tubing Bundles Installation Guide Heating solutions for instrument and small-diameter process lines RTB Tubing Bundles Installation Guide Heating solutions for instrument and small-diameter process lines 1 / 20 WARNING: Fire and shock hazard. Raychem heat-tracing systems must be installed correctly to

More information

Tubing Data. Contents. Tubing Selection. Tubing Handling. Tubing Material. Tubing Outside Diameter Hardness. Tubing Wall Thickness

Tubing Data. Contents. Tubing Selection. Tubing Handling. Tubing Material. Tubing Outside Diameter Hardness. Tubing Wall Thickness www.swagelok.com Tubing Data Contents Tubing Selection... 1 Tubing Handling.... 1 Gas Service... 2 Tubing Installation.... 2 Suggested Allowable Working Pressure Tables Carbon Steel Tubing... 3 Stainless

More information

Tubing and Accessories

Tubing and Accessories Section 7 Tubing and Accessories Inch Industrial Tubing................................FIT-7-2 Metric Industrial Tubing...............................FIT-7-3 Inch D.O.T. Tubing...................................FIT-7-3

More information

Stainless Steel Valves For the Sanitary Industries

Stainless Steel Valves For the Sanitary Industries www.swagelok.com Stainless Steel Valves For the Sanitary Industries Sanitary ball valves Manual and pneumatically actuated butterfly valves Disk and ball check valves ir blow check valves ir relief valves

More information

Terminal Cleaning and Protection

Terminal Cleaning and Protection Terminal Cleaning and Protection East Penn offers the most complete line of terminal cleaning and protection products. Boots Heat Shrink Tubing Cleaner and Protection Sprays Terminal Protectors 33 PAGES

More information

Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.

Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt. Thermwire Freeze Protection Heating Cable Selection Guide Pipe Freeze Protection Heating Cable Pre-Assembled Pipe Freeze Protection Heating Cable with Attached Cord & Plug Thermwire-Comp Refrigeration

More information

Hook-Up and Lead Wire

Hook-Up and Lead Wire 3.1 Hook-Up and Lead Wire 3 Table of Contents Hook-Up & Lead Wire Page Introduction: UL Style & CSA Type Listings 3.2 PVC 3.3 3.8 300V, 80 C 3.3 300V, 105 C 3.4 600V, 105 C 3.5 (Type MW) MIL-W-76C-PVC:

More information

Contact Information: 4031-0001 Electrical Connection Kit for CL Series Constant Wattage Temptrace for Low Temperature Maintenance.

Contact Information: 4031-0001 Electrical Connection Kit for CL Series Constant Wattage Temptrace for Low Temperature Maintenance. Technical Data Sheet & Installation Instructions for 4031-0001 Electrical Connection Kit for CL Series Constant Wattage Temptrace for Low Temperature Maintenance Bulletin CL-II Contact Information: Parker

More information

C A B L E P R O T E C T I O N

C A B L E P R O T E C T I O N Safe cable protection! Elematic Cabling Systems produces in own plants a wide range of products for the cable protection, such as wiring spirals, insulated tubing, heat shrinkable tubing, etc. These products

More information

UNITHERM UNITHERM 2256/2266 SELF-REGULATING ELECTRIC TRACE TUBING

UNITHERM UNITHERM 2256/2266 SELF-REGULATING ELECTRIC TRACE TUBING UNITHERM UNITHERM 2256/2266 SELF-REGULATING ELECTRIC TRACE TUBING HIGH TEMPERATURE MAINTENANCE AND STEAM CLEANED LINES Principal of Operation Unitherm 2256/2266 HTM (High Temperature Maintenance) Electric

More information

I-Line. Accessories. Essential cable installation products for corrugated, smooth wall, and braided cables

I-Line. Accessories. Essential cable installation products for corrugated, smooth wall, and braided cables I-Line TM Essential cable installation products for corrugated, smooth wall, and braided cables Installation Coaxial cable installation components for corrugated, smooth wall and braided cables Proven

More information

TubeTrace, ThermoTube

TubeTrace, ThermoTube TubeTrace, ThermoTube and Custom CEMS Tubing Bundles INSTALLATION PROCEDURES English Units TubeTrace & ThermoTube Tubing Bundles Receiving, Storing and Handling... 1. Inspect materials for damage incurred

More information

60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING 60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed

More information

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs. Skylight Installation Instructions This document provides instruction and guidelines for installation of both curb mount (CM) and self flashing (SF) unit skylights on flat, pitched (> or equal to 3/12

More information

3 Single-Coated Foam Tapes

3 Single-Coated Foam Tapes 3 Single-Coated Foam Tapes Technical Data May, 2008 Product Description 3M Single-Coated Foam Tapes will adhere to a variety of substrates, including latex-painted wood, lacquered wood, enameled steel,

More information

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES CONTINENTAL INDUSTRIES ABOUT US THE ULTIMATE CONNECTION Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and is today

More information

RE-ENTERABLE SPLICE CLOSURE KITS. (For Air Core None Pressurized Cable)

RE-ENTERABLE SPLICE CLOSURE KITS. (For Air Core None Pressurized Cable) Triple T Broadband Public Co., Ltd. Outside Plant Standard Sector Specification No. OES-001-027-04 Issued: RE-ENTERABLE SPLICE CLOSURE KITS (For Air Core None Pressurized Cable) 1. SCOPE 1.1. This specification

More information

Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls

Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls Pre- insulated pipe systems ecoflex Wall Penetration installation guide Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls Pre-insulated Pipe Systems

More information

Multipurpose Ball Valves

Multipurpose Ball Valves www.swagelok.com Multipurpose Ball Valves 33 Series Working pressures up to 6000 psig (413 bar) High flow capacity in a compact design Available with PEEK and UHMWPE seats Variety of end connections Low

More information

Proportional Relief Valves

Proportional Relief Valves www.swagelok.com Proportional Relief Valves R Series Liquid or gas service Set pressures from 10 to psig (0.7 to 413 bar) 1/4 and 1/2 in. and 6 to 12 mm end connections 2 Proportional Relief Valves Spring

More information

SECTION 15190 HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section 15010.

SECTION 15190 HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section 15010. SECTION 15190 HVAC INSULATION PART ONE - GENERAL PART 1 - GENERAL 1.01 DESCRIPTION A. All work specified in this Section is subject to the provisions of Section 15010. B. All insulation products shall

More information

Pictorial Index... A-14 Introduction to Heat Trace Cable Systems... 6-2 Installation Examples... 6-3 Engineering Guide... 6-4 Heat Loss Tables...

Pictorial Index... A-14 Introduction to Heat Trace Cable Systems... 6-2 Installation Examples... 6-3 Engineering Guide... 6-4 Heat Loss Tables... Pictorial Index....................... A-14 Introduction to Heat Trace Cable Systems............... 6-2 Installation Examples................... 6-3 Engineering Guide..................... 6-4 Heat Loss

More information

LHD LINEAR HEAT D ETECTIONN

LHD LINEAR HEAT D ETECTIONN Tri-Metallic Core: Steel provides tensile strength Copper increase conductivity Tin for corrosion resistance LHD LINEAR HEAT D ETECTIONN TECHNICAL DATA Temperature Rating: 155 F (68 C) (typical temperature)

More information

Model CS 64 Mini-DIN Cable and Adaptor

Model CS 64 Mini-DIN Cable and Adaptor Model CS 64 Mini-DIN Cable and Adaptor Page 1 of 9 Features Hi-Pro and NOAHlink compatible cable & Mini-DIN CS 64 Clip Module / NOAHlink Adaptor #1 Integrated Clip Module - Mini-DIN Cable Integrated NOAHlink

More information

Valu Guide Sheaths. Valu Guide Inserts. Optional Valu Guide Inserts. Typical Properties of Valu Guide Rail. and Hardware.

Valu Guide Sheaths. Valu Guide Inserts. Optional Valu Guide Inserts. Typical Properties of Valu Guide Rail. and Hardware. 14 gauge stainless steel The Original, Long Life Sanitary Guide Rail Valu Guide rail incorporates two outstanding materials: stainless steel and UHMW. The 14 ga. stainless steel sheath provides rigid streamlined

More information

Scraper Passage Indicator. Electrical Indicator. Features

Scraper Passage Indicator. Electrical Indicator. Features IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage

More information

HOSE AND TUBING CATALOGUE SOLD BY THE ROLL OR IN INCREMENTS OF 1M, STANDARD COIL LENGTH 30 METRES. SIZE (I.D x WALL) CODE SIZE (I.

HOSE AND TUBING CATALOGUE SOLD BY THE ROLL OR IN INCREMENTS OF 1M, STANDARD COIL LENGTH 30 METRES. SIZE (I.D x WALL) CODE SIZE (I. FUEL LINE Temperature: -40 C to +125 C continuous service. Tube: Type C (Nitrile). Black. Oil and petrol resistant. Reinforcement: Single ply of synthetic fibre. Cover: Type C2 (NBR/PVC). Black. Fuel,

More information

Communication, Signal & Data Cables

Communication, Signal & Data Cables Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication

More information

4 Installation Requirements

4 Installation Requirements 4 Installation Requirements 9 4.1 Code Reference The authority having jurisdiction should be referenced to determine what law, ordinance or code shall apply in the use of flexible duct. Ducts conforming

More information

COATING & WRAPPING OF UNDERGROUND PIPING

COATING & WRAPPING OF UNDERGROUND PIPING CONSTRUCTION STANDARD SPECIFICATION DOCUMENT NO :SEC-PJ-000-SPC-PI-008 TOTAL PAGES : 8 Page 1 of 8 CONTENTS 1. SCOPE 2. DEFINITION 3. CODES AND STANDARDS 4. MATERIALS Page 2 of 8 1. SCOPE This specification

More information

Solar Hot Water Heaters

Solar Hot Water Heaters Solar Hot Water Heaters Three High Vacuum Water inlet Stainless Steel screw Gel seal and insulation Water outlet Dust proof seals Non Pressure Models Details ASWH-1b ( Color Painted 304 ) ASWH-1c ( stainless

More information

Compact, High-Flow Gas Regulators

Compact, High-Flow Gas Regulators www.swagelok.com Compact, High-Flow Gas Regulators HF Series Precise pressure control Tamper-free design High-purity design Preset and adjustable dome-loaded models 2 Compact, High-Flow Gas Regulators

More information

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS CONDUCTORS Conductors are needed to complete the path for electrical current to flow from the power source to the working devices and back to the power source. Special wiring is needed for battery cables

More information

How To Buy A Designo Grille

How To Buy A Designo Grille anal ompact anal Plus 1 2 3 1. omplete anal Plus underfloor unit 2. Heat exchanger and inside finish of the duct in dark grey 3. Enlarged range of grilles anal Plus Operating principal Options Flexible

More information

Pipe Protection Tape System

Pipe Protection Tape System Pipe Protection Tape System PASCO All Weather Pipe Protection Tape is a pure physical barrier that is moisture proof, inert and non-conducting. Whether the need is to protect overhead piping in industrial

More information

Fire Barrier Duct Wrap 15A

Fire Barrier Duct Wrap 15A 3 Fire Barrier Duct Wrap 15A Commerical Kitchen Grease Duct Fire Protection System Product Data and Installation Instructions Compliance 1998 Edition Complies with International Mechanical Code Complies

More information

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED SQUARE TUBE LADDER

More information

Pipe Clamps and Accessories

Pipe Clamps and Accessories Products 4.0 Products 4.1 Connection options to pipe clamps with Triple-Thread Connector NT 3G (M16, M10, M8) 4.2 Connection options to pipe clamps with Triple-Thread Connector NT 3G (3/8", M12, M10) 4.3

More information

Double Coated Urethane Foam Tapes

Double Coated Urethane Foam Tapes 3 Double Coated Urethane Foam Tapes 4004 4008 4016 4026 4032 4052 4056 4085 Technical Data April, 2009 Product Description 3M Double Coated Urethane Foam Tapes are conformable foams that offer high shear

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The

More information

James M. Pleasants Company

James M. Pleasants Company James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:

More information

FLEXIBLE THERMAL INSULATION MADE OF SILICONE 2012-06

FLEXIBLE THERMAL INSULATION MADE OF SILICONE 2012-06 FLEXIBLE THERMAL INSULATION MADE OF SILICONE 2012-06 Table of Contents 1. Flexible, thermal insulation made of Silicone...3 1.1 Features and benefi ts...3 1.2 Designs...3 1.3 Silicone processing at Winkler...3

More information

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa Profiles in stock Standard catalogue Discover the possibilities with aluminium from Sapa You can create your own profile or you can choose from a wide selection of standard. Delivery: 1 2 weeks for standard

More information

3 Marine Adhesives and Sealants

3 Marine Adhesives and Sealants 3 Marine Adhesives and Sealants For Demanding Marine Environments Providing secure bonds, in the water or out. Almost no environment is harsher than the beating sun and pounding waves of the open water.

More information

ROOF FLASHING SPRINGLOK FLASHING SYSTEM FEATURES & BENEFITS PRODUCT DESCRIPTION

ROOF FLASHING SPRINGLOK FLASHING SYSTEM FEATURES & BENEFITS PRODUCT DESCRIPTION SPRINGLOK SYSTEM PRODUCT DESCRIPTION FEATURES & BENEFITS Fry Reglet offers five flashing systems, each tailored for a particular type of substrate so you can get exactly what you need. SM Surface mounted

More information

JIS G3472 Electric Resistance Welded Carbon Steel Tubes for Automobile Structural Purposes

JIS G3472 Electric Resistance Welded Carbon Steel Tubes for Automobile Structural Purposes JIS G3472 Electric Resistance Welded Carbon Steel Tubes for Automobile Structural Purposes 1. Scope This Japanese Industrial Standard specifies the electric resistance welded carbon steel tubes, hereinafter

More information

HyLife TM HVAC Line Corrosion testing. Precision Tubing Technology Centre, 2012

HyLife TM HVAC Line Corrosion testing. Precision Tubing Technology Centre, 2012 Precision Tubing Technology Centre, 2012 Background: There is an increasing interest in the use of aluminium tubes for connecting lines for residential HVACR applications Connecting lines are often covered

More information

TEXAS A&M CENTRAL ACADEMIC BUILDIING & PATRIOT S CASA SUBMITTAL. 23 21 13.19 Pre-Insulated Piping 4-8-13

TEXAS A&M CENTRAL ACADEMIC BUILDIING & PATRIOT S CASA SUBMITTAL. 23 21 13.19 Pre-Insulated Piping 4-8-13 TEXAS A&M CENTRAL ACADEMIC BUILDIING & PATRIOT S CASA SUBMITTAL 23 21 13.19 Pre-Insulated Piping 4-8-13 MATERIAL SUBMITTAL JOB NAME: TEXAS A&M SAN ANTONIO CENTRAL ACADEMIC BUILDING & PATRIOTS CASA CONTRACTOR:

More information

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description Product Data Sheet Edition 15/10/2014 Identification no: 02 07 04 10 300 0 000002 SikaProof A Edge SikaProof A-08 Edge, A-12 Edge Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing

More information

Variable Area Flowmeters

Variable Area Flowmeters www.swagelok.com Variable Area Flowmeters G Series and M Series Glass and metal (armored) tube models, including miniature armored model Highly accurate measurement with individually calibrated scales

More information

Seamless stainless tubes for hydraulic and instrumentation systems

Seamless stainless tubes for hydraulic and instrumentation systems Seamless stainless tubes for hydraulic and instrumentation systems stock assortment integrated production technical knowledge network of sales and service Reduce your lifecycle costs When selecting tubes

More information

TMC CableReady Connectors For Jacketed Metal Clad Cable TMC For Non-Hazardous Locations

TMC CableReady Connectors For Jacketed Metal Clad Cable TMC For Non-Hazardous Locations TMC CableReady Connectors For Jacketed Metal Clad Cable TMC For Non-Hazardous Locations CableReady connectors are designed for use with the following cables: Type MC jacketed corrugated aluminum, interlocked

More information

07 21 19 Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

07 21 19 Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM 07 21 19 STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM 7819 Broadview Road Cleveland, OH 44131 800-522-4522 February, 2011 SPEC NOTE: This guide specification is intended for use when specifying

More information

Embedded Parts Introduction - Anchors

Embedded Parts Introduction - Anchors In the plant construction or process plants such as chemical, petrochemical, gas or power plants various disciplines are brought into contact and built on each other. Civil, mechanical, electro technical

More information

Cable Tie Mounting Bases

Cable Tie Mounting Bases Temperature Rating: 0ºC to 66ºC (32ºF to 150ºF) *Synthetic Rubber Adhesive Choose from adhesive-backed, epoxy or screw mounting bases! Available in a variety of materials for both indoor and outdoor use

More information

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction

More information

Items Supplied. Frequency. Designation Description / Delivery Unit Order Number

Items Supplied. Frequency. Designation Description / Delivery Unit Order Number Fiber Optic Cleaver D6 For Single- and Multimode Fibers Diamond blade for highest cleave quality and long life (typically > 10,000 cleaves) Fiber cleave length: 3.5 to 15 mm Fiber diameter: 125 µm nominal

More information

Specification for Rotary Drill Stem Elements

Specification for Rotary Drill Stem Elements Addendum 1 March 2007 Effective Date: September 1, 2007 Specification for Rotary Drill Stem Elements ANSI/API SPECIFICATION 7-1 FIRST EDITION, MARCH 2006 EFFECTIVE DATE: SEPTEMBER 2006 ISO 10424-1:2004

More information

3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form

3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form 3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form THIS FULLY COMPLETED DOCUMENT MUST BE INCLUDED WITH EACH RETURN SHIPMENT IN ORDER FOR CREDIT TO BE ISSUED. ALL CREDITS WILL BE ISSUED TO

More information

Catalog May 2015. Cable Accessories < 1 kv

Catalog May 2015. Cable Accessories < 1 kv Catalog May 2015 Cable Accessories < 1 kv Table of content Cable Accessories 1 Cable Accessories 1 kv Product range 2 Universal cleats 3 List of content 4 Notes 5 We reserve the right to make technical

More information

Offering more. Series 3000 www.ripack.com

Offering more. Series 3000 www.ripack.com Offering more Series 3000 SAFE Prevent any burn risks and work in complete safety. With its unique, patented cold nozzle system, the gun remains cool during use. PRACTICAL Large, solid hanger ring. FAST

More information

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW is a fully reinforced Pre-Applied system membrane designed for horizontal and vertical external blind-side

More information

Incubator with mechanical convection

Incubator with mechanical convection BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,

More information

Toroidal Conductivity Sensor

Toroidal Conductivity Sensor Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:

More information

Division 9. SignaFlor Pad and Pour Flooring System

Division 9. SignaFlor Pad and Pour Flooring System Division 9 SignaFlor Pad and Pour Flooring System SPECIFICATIONS Page 1. General... 2 1.1 Description 2 1.2 Quality Assurance 2 1.3 Submittals 2 1.4 Delivery and Storage 3 1.5 Warranty 3 1.6 Working Conditions

More information

CRS Sales & Marketing

CRS Sales & Marketing TPO - Technology CRS Sales & Marketing Presenter: Gena Miller Thank you AIA, Sign In Sheet (1 Hour CEU-HSW) Division of CRS, Inc. (Commercial Roofing Specialties) 5 Locations (4 state of GA, 1 state of

More information

RTV162. Electronic Grade Silicone Adhesive Sealant

RTV162. Electronic Grade Silicone Adhesive Sealant RTV162 Product Description Electronic Grade Silicone Adhesive Sealant RTV162 adhesive sealant from GE Silicones is one-component, readyto-use electronic grade silicone sealant. It cures to a tough, resilient

More information

THERMA-TUBE preinsulated pipes and fittings Catalogue of products

THERMA-TUBE preinsulated pipes and fittings Catalogue of products THERMA-TUBE preinsulated pipes and fittings Catalogue of products THERMA TUBE preinsulated pipes and fittings TABLE OF CONTENTS 1. GENERAL INFORMATION ABOUT THE USE OF PREINSULATED PIPES AND FITTINGS...

More information

FLEX-WRAP Foam Pipe Wrap

FLEX-WRAP Foam Pipe Wrap FLEX-WRAP Foam Pipe Wrap Flex-wrap Inexpensive Used to wrap all pipes in a concrete pour Satisfies UPC Code Sec.315.7 Provides true expansion space between pipe and a concrete pour Product # Dimesions

More information

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description Worldwide Contacts www.tyco-fire.com Model F thru F3 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description The Mulsifyre Nozzles are open (nonautomatic) nozzles and they are designed

More information

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.

More information

1.5. UL flammability ratings. *Nylon 6.6 = Polyamide 6.6 is Halogen-free and Silicone-free.

1.5. UL flammability ratings. *Nylon 6.6 = Polyamide 6.6 is Halogen-free and Silicone-free. 1.5 UL flammability ratings WWW.CABLEJOINTS.CO.UK THORNE & DERRICK UK TEL 0044 191 490 1547 FAX 0044 191 477 5371 TEL 0044 117 977 4647 FAX 0044 117 977 5582 WWW.THORNEANDDERRICK.CO.UK Flammability ratings

More information

Africa s leading steel supplier CATALOGUE TUBE & PIPE. The Macsteel Group - Africa s leading steel supplier - www.macsteel.co.za

Africa s leading steel supplier CATALOGUE TUBE & PIPE. The Macsteel Group - Africa s leading steel supplier - www.macsteel.co.za Africa s leading steel supplier CATALOGUE TUBE & PIPE - www.macsteel.co.za TUBE & PIPE CONTENTS 1. Contents 13. Conveyance SANS 1182 - Light Page 7 2. Contact Details 14. Conveyance SANS 719 - Large Bore

More information

Simple, Comprehensive Tubing Solutions. Alpha Wire Company

Simple, Comprehensive Tubing Solutions. Alpha Wire Company Simple, Comprehensive Tubing Solutions Alpha Wire Company Quality Solutions Reliability FIT Heat Shrink Products are made from premium compounds under the tightest manufacturing controls. This means FIT

More information

CABLE 101. The Basics of Wire & Cable. Copyright 2007, Belden Inc.

CABLE 101. The Basics of Wire & Cable. Copyright 2007, Belden Inc. CABLE 101 The Basics of Wire & Cable Copyright 2007, Belden Inc. KEY TERMS Insulations Jacket Capacitance Attenuation Velocity of propagation Dielectric strength Dielectric constant Working voltage Elongation

More information

IS800 Series. Technical Data Sheet IS802, IS803, IS808, IS800.09. Description. Key Features and Benefits. Typical Physical Properties

IS800 Series. Technical Data Sheet IS802, IS803, IS808, IS800.09. Description. Key Features and Benefits. Typical Physical Properties 1810.html Technical Data Sheet IS800 Series IS802, IS803, IS808, IS800.09 Description IS802, IS803, IS808 and IS800.09 one-component, ready-to-use silicone adhesive sealants have a paste-like consistency

More information

Festoon 715 P PUR cable for flexible application in festoon systems

Festoon 715 P PUR cable for flexible application in festoon systems CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P 07150162:

More information

Working Pressure up to 630 bar / 9135 PSI

Working Pressure up to 630 bar / 9135 PSI Test Hoses SMS / SS + Working Pressure up to 630 bar / 9135 PSI Technical Data for Test Hose A B C D Nominal Bore () (mm) Max. Working Pressure (PN) (bar / PSI) 00 / 5801 630 / 9135 30 / 931 630 / 9135

More information

Athena is the name given to our assortment of electronic tapes. products of the very highest quality. These tapes both conduct and

Athena is the name given to our assortment of electronic tapes. products of the very highest quality. These tapes both conduct and Electric Athena. Athena is the name given to our assortment of electronic tapes products of the very highest quality. These tapes both conduct and insulate against electricity, in addition to warmth and

More information

Mini USB and USB 2.0-IP67 Connector System

Mini USB and USB 2.0-IP67 Connector System Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet

More information

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS

More information

ETHERLINE Ethernet Cable, Connectors & Tools

ETHERLINE Ethernet Cable, Connectors & Tools Ethernet Cable, ors & Tools 2 Pair 242 4 Pair 249 Industrial Ethernet ors & Tools 256 Ethernet Cable, ors & Tools ETHERNET CABLE, CONNECTORS & TOOLS Quick Select Chart 240 2 Pair 2 Pair: CAT.5/5e; Stationary

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

SIMPLAIR PIPING. www.irtools.com 1-800-376-TOOL

SIMPLAIR PIPING. www.irtools.com 1-800-376-TOOL SIMPLAIR PIPING INGERSOLL-RAND SIMPLAIR PIPING With push-in fittings and lightweight anodized aluminum pipe, a SimplAir system provides ideal connection throughout your entire air distribution system.

More information

SunMor SM-V30 Solar Water Heater Installation Manual

SunMor SM-V30 Solar Water Heater Installation Manual SunMor SM-V30 Solar Water Heater Installation Manual Rev. 1.02 Congratulations on the purchase of your new SunMor SM-V30 from Nature s Comfort LLC! You must read this entire instruction manual before beginning

More information

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list VITOSOL 100 Flat collectors for the utilisation of solar energy Data Sheet Part nos. and prices: see price list File in: Vitotec 1 Manual, Index 16 Vitosol 100 Type s 1.7 Vitosol 100 Type s 2.5 Vitosol

More information

MAC-120HE-01 Air-Cooled Chiller

MAC-120HE-01 Air-Cooled Chiller MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01

More information

Vacuum Tube Solar Water heater Non-pressure. User manual

Vacuum Tube Solar Water heater Non-pressure. User manual Vacuum Tube Solar Water heater Non-pressure User manual Please read this manual carefully before beginning installation Specification Tubes 12 --- 30 58X1800 Nominal volume tank capacity 100L --- 300L

More information

Directory chapter 04

Directory chapter 04 M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................

More information

T1-K. OPEN SLOT RIGID PVC (including cover) OPEN SLOT BLACK RIGID PVC (including cover) 2 PRICE LIST WD 115 STANDARD CARTON - FT LENGTHS PER CARTON

T1-K. OPEN SLOT RIGID PVC (including cover) OPEN SLOT BLACK RIGID PVC (including cover) 2 PRICE LIST WD 115 STANDARD CARTON - FT LENGTHS PER CARTON T1 OPEN SLOT RIGID PVC (including cover) millimeters LENGTHS PER CARTON STANDARD CARTON - FT PER FOOT (3) T1-0506G 1/2 x 5/8 15 x 18 20 120 $3.58 T1-0510G 1/2 x1 15 x 30 20 120 $3.80 T1-0522G 1/2 x 2-1/4

More information

PUSH-PULL CABLES CONTROL SYSTEMS

PUSH-PULL CABLES CONTROL SYSTEMS ISO 9001 CERTIFIED PUSH-PULL CABLES CONTROL SYSTEMS WESCON PRODUCTS COMPANY A subsidiary of LATSHAW ENTERPRISES, INC. WESCON'S PUSH-PULL CONTROL SYSTEMS Push-Pull Cable Ends Wescon Push-Pull Cable Assemblies

More information

UGVCL/SP/591/11KV HT AB CABLE

UGVCL/SP/591/11KV HT AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched

More information

Typical values for a Kapton Polyimide tape wrapped sample, according to NEMA Specifications

Typical values for a Kapton Polyimide tape wrapped sample, according to NEMA Specifications DACRON DACRON GLASS FIBER COVERED MAGNET WIRE CLASS 200 INSULATION DACRON Glass Fiber-covered Magnet Wire is manufactured by serving a combination of glass and Dacron fibers over a bare or film-coated

More information

www.klmtechgroup.com TABLE OF CONTENT

www.klmtechgroup.com TABLE OF CONTENT Page : 1 of 31 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 2 REFERENCES

More information

Cables. Accessories. For Force, Torque and Strain Sensors

Cables. Accessories. For Force, Torque and Strain Sensors Accessories Cables For Force, Torque and Strain Sensors Charge mode, high impedance piezoelectric measurement demands highly insulated coaxial cables and connectors to ensure an insulation resistance greater

More information

Cable Runways & Accessories

Cable Runways & Accessories SB17U SB13AL SB17 SB17T SB117 SB17HRB SB2107 SB2101A SB17VRB SB2110A SB2129 SB2129SD SB130 SB2221 SB126 SB2118 SB119 SB2105 113 Cooper B-Line manufactures a wide variety of high quality cable pathway products

More information

SECTION 07530 SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings.

SECTION 07530 SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings. SECTION 07530 PART 1 - GENERAL 1.01 DESCRIPTION A. This Section includes the flowing: 1. Removal of existing roofing membrane. Existing bur roof has one overlay and penetration mastic is asbestos containing.

More information

Times Microwave Systems Hermetically Sealed Assemblies

Times Microwave Systems Hermetically Sealed Assemblies SCOPE This Specification details the Electrical, Mechanical and Environmental Characteristics of Times Microwave Systems MILTECH 340.34 Diameter Hermetically Sealed Coaxial Transmission Lines. This product

More information

3M Electrically Conductive Adhesive Transfer Tape 9703

3M Electrically Conductive Adhesive Transfer Tape 9703 Technical Data April 2011 M Electrically Conductive Adhesive Transfer Tape 970 Product Description M Electrically Conductive Adhesive Transfer Tape 970 is a pressure sensitive adhesive (PSA) transfer tape

More information