TAS-18MVHN/O TAS-27MVHN/O TAS-36MVHN/O
|
|
- Shon Norman
- 7 years ago
- Views:
Transcription
1 SERVICE MANUAL AIRCONDITIONER DC INVERTER MULTI TYPE TAS-18MVHN/O TAS-27MVHN/O TAS-36MVHN/O DC MULTI OUTDOOR UNITS
2 CONTENTS 1. General information of Outdoor Units Dimensions Wiring Diagram Refrigeration Cycle Diagram Indoor units combination Electronic control function Troubleshooting... 14
3 1. General information of Outdoor Units Outdoor unit Power relay control Low noise air flow system Hydrophilic aluminum fin The hydrophilic fin can improve the heating efficiency at operation mode. 4 way valve control It is only operated in the heating operation mode except defrosting operation. Anti-rust cabinet Valve protection cover It protects the valves and prevents water from dripping. Discharge pipe temperature protection Compressor crankcase heater
4 2. Dimensions a) TAS-18MVHN / O TAS-27MVHN/ O b) TAS-36MVHN / O
5 3. Wiring Diagram 3.1 TAS-18MVHN/O 3.2 TAS-27MVHN/O
6 3.3 TAS-36MVHN/O
7 4. Refrigeration Cycle Diagram 4.1 Refrigeration circuit drawing of inverter binary type Exhaust temp. sensor Axial flow fan Main Capillary Auxiliary Capillary EXVA Capillary A EXVB Filter A Liquid valve A 4-way valve Condenser Coil temp. sensor Check Valve Capillary B Filter B Liquid valve B flow fan Cross Evaporator Indoor pipe out temp. sensor A Gas valve A Compressor Indoor pipe out temp. sensor B Gas valve B Outdoor Unit Indoor Unit 4.2 Refrigeration circuit drawing of inverter trinary type Exhaust temp. sensor Axial flow fan Main Capillary Auxiliary Capillary Capillary A Capillary B EXV A EXV B Filter A Liquid valve A Liquid valve B 4-way valve Condenser Coil temp. sensor Check Valve Capillary C EXV C Filter B Filter C Liquid valve C flow fan Cross Evaporator Compressor Indoor pipe out temp. sensor A Indoor pipe out temp. sensor B Indoor pipe out temp. sensor C Gas valve A Gas valve B Gas valve C Outdoor Unit Indoor Unit 4.3 Refrigeration circuit drawing of inverter quadplex type
8 5. Indoor units combination 5.1 Indoor unit combination for MTAS-18MVHN/O One unit Two unit Indoor unit combination for TAS-27MVHN/O One unit Two unit Three unit Indoor unit combination fortas-36mvhn/o One unit Two unit Three unit Four unit
9 6. Electronic control function 6.1 Abbreviation T1: Indoor ambient temperature T2: Coil temperature of indoor heat exchanger middle. T2B: Coil temperature of indoor heat exchanger outlet. T3: Coil temperature of outdoor heat exchanger T4: Outdoor ambient temperature T5: Compressor discharge temperature Ts: Setting temp. 6.2 Electric control working environment Input voltage: 230V Input power frequency:60hz Indoor fan normal working amp. is less than 1A Outdoor fan. rmal working amp. is less than 1.5A Four-way valve normal working amp. is less than 1A Swing motor: DC12V. 6.3 Outdoor unit s digital display tube There is a digital display tube in outdoor PCB. Digital display tube display function In standby, the LED displays - - In compressor operation, the LED display the running frequency, In defrosting mode, The LED displays df or alternative displays between running frequency and df (each displays 2s) In compressor pre-heating, The LED displays - - In protection or malfunction, the LED displays error code or protection code. 6.4 Outdoor unit point check function There is a check switch in outdoor PCB. Push the switch SW1 to check the states of unit when the unit is running. The digital display tube will display the follow procedure when push SW1 each time. Display 1 Indoor unit capacity demand code Remark 2 Outdoor unit running mode code Off:0, Cooling:1, Heating:2 3 Amendatory capacity demand code 4 Outdoor unit fan motor state Off:0, Low speed:1, High speed:2 5 Evaporator outlet temp. for 1# indoor unit Actual data 6 Evaporator outlet temp. for 2# indoor unit Actual data 7 Evaporator outlet temp. for 3# indoor unit Actual data 8 Evaporator outlet temp. for 4# indoor unit Actual data 9 Condenser pipe temp. Actual data 10 Ambient temp. Actual data 11 Compressor discharge temp. Actual data 12 Inverter current Actual data 13 EXV open angle for 1# indoor unit Actual data divide 8
10 14 EXV open angle for 2# indoor unit Actual data divide 8 15 EXV open angle for 3# indoor unit Actual data divide 8 16 EXV open angle for 4# indoor unit Actual data divide 8 17 Power supply of outdoor unit AD data 18 Indoor unit number The indoor unit can communicate with outdoor unit well. 19 The last error or protection code 00 means no malfunction 20 frequency value Actual data 21 Ambient temp. of 1# indoor unit Actual data 22 Condenser pipe temp. of 1# indoor unit Actual data 23 Ambient temp. of 2# indoor unit Actual data 24 Condenser pipe temp. of 2# indoor unit Actual data 25 Ambient temp. of 3# indoor unit Actual data 26 Condenser pipe temp. of 3# indoor unit Actual data 27 Ambient temp. of 4# indoor unit Actual data 28 Condenser pipe temp. of 4# indoor unit Actual data 29 Check point over The following items from to are for the explanation of the point check functions Frequency of compressor: Display Frequency of compressor (Hz) Stand by Running mode: Display Corresponding mode 0 Off 1 Cooling mode 2 Heating mode Capacity demand: Cooling mode Capacity >7500 Correspondi ng Code >=10 Heating mode Capacity >8000 Correspondin g Code >=11 te: The capacity is just for reference.
11 6.4.4Number of indoor unit Display Number of indoor unit Outdoor ambient temp:
12 6.4.6 Opening degree of electronic expansion valve: Actual opening degree equals the display data divided Protection Three minutes delay at restart for compressor Temperature protection of compressor discharge. When the compressor discharge temp. is getting higher, the running frequency will be limited as below rules: ----If 102 (216 ) <T5<115 (239 ), decrease the freq uency to the lower level every 2 minutes till to F1. ---If T5>115 (239 ) for 10 seconds, the compressor will stop and restart till T5<90. (194 ) Low voltage protection VOLTAGE VOLLIMT1 VOLLIMT2 VOLLIMT3 limit VOLFRE1 VOLFRE2 Off VOLREL1 VOLREL2 VOLREL3 Model VOLLIMT1 VOLLIMT2 VOLLIMT3 VOLREL1 VOLREL2 VOLREL3 VOLFRE1 VOLFRE2 M2OC-18HRDN1-M M3OC-27HRDN1-M M4OC-36HRDN1-M te: if the low voltage protection occurs and not resumes within 3min, it will keep the protection always after restart the machine Compressor current limit protection If the compressor current exceeds the current limit value for 10 seconds, the compressor frequency will be limited as below table. Cooling mode: Current frequency(hz) Current limit value(a) Frequency limit COOL_F10 COOL_F9 COOL_F8 COOL_F7 COOL_F6 COOL_F5 ICOOLLMT6 ICOOLLMT5 ICOOLLMT4 ICOOLLMT3 ICOOLLMT2 ICOOLLMT1 Decrease the frequecny to COOL_F4 and run at COOL_F4 for 3 minutes. After that,the frequency will be adjusted according to the capacity demand and rise to the upper level every 3 minutes (When the frequency>cool_f4 via capacity demand). If the current frequency is lower than COOL_F4, the frequency will not be limited. After 10s of the compressor start, if the current>icool,the AC will display the failure for 30 seconds and stop. The AC will restart 3 minutes later. Heating mode: Current frequency(hz) Current limit value(a) Frequency limit HEAT_F12 HEAT_F11 HEAT_F10 HEAT_F9 HEAT_F8 IHEATLMT8 IHEATLMT7 IHEATLMT6 IHEATLMT5 IHEATLMT4 Decrease the frequency to HEAT_F4 and run at HEAT_F4 for 3 minutes. After that, the frequency will be adjusted according to the capacity demand and rise to the upper level every 3 minutes
13 HEAT_F7 HEAT_F6 HEAT_F5 IHEATLMT3 IHEATLMT2 IHEATLMT1 (When the frequency>heat_f4 via capacity demand). If the current frequency is lower than HEAT_F4, the frequency will not be limited. After 10s of the compressor start, if the current>iheat,the AC will display the failure for 30 seconds and stop. The AC will restart 3 minutes later Indoor / outdoor units communication protection If the indoor units can not receive the feedback signal from the outdoor units for 2 minutes, the AC will stop and display the failure High condenser coil temp. protection. When T3>65 (149 ) for 3 seconds, the compressor will stop while the indoor fan and outdoor fan will continue. When T3<52 (126 ), the protection will release and the compressor will restart after 3 minutes Outdoor unit anti-freezing protection When T2B<0 (32 )for 250 seconds, the indoor unit capacity demand will be zero and resume to normal when T2B>10 (50 ) Oil return Running rules: 1. If the compressor frequency keeps lower than RECOILINFRE for 2hours,the AC will rise the frequency to RECOILFRE for 3mins and then resume to former frequency. Model RECOILINFRE TAS-18MVHN/O 45 TAS-27MVHN/O 45 TAS-36MVHN/O During the oil return process, the EXV and indoor units keep the current running mode, the frequency will not be limited by the compressor discharge temp. and the current Compressor preheating functions ----Preheating permitting condition: If T4(outdoor ambient temperature)<3 (37.4 ) and newly powered on or if T4 <3 (37.4 ) and compressor has stopped for over 3 hours, the comp ressor heating cable will work. ----Preheating mode: A weak current flow through the coil of compressor from the wiring terminal of compressor, then the compressor is heated without operation. ----Preheating release condition: If T4>5 or the compressor starts running, preheating function will stop Compressor crankcase heater When T4<3 (37.4 ), and the compressor is not running,the crankcase heater will be active. When T4 5 (41 ) or the compressor starts up,the crankcase heater will stop work.(for TAS-36MVHN/O T4 8 (46.4 )
14 7. Troubleshooting 7.1 Indoor unit error code explanation: Vertu series: Display E0 E1 E2 E3 E5 E6 P0 P1 P2 P3 P4 EEPROM error Communication error between indoor and outdoor unit Zero-crossing examination error Fan speed beyond control Outdoor units temp. sensor or connector of temp. sensor is defective Indoor units temp. sensor or connector of temp. sensor is defective Inverter module protection Outdoor voltage too low protection Compressor discharge temp. protection Outdoor temp. too low protection Compressor driving protection 7.2 Outdoor unit error code explanation: Display E0 E1 E2 E3 E6 E4 E5 E7 P0 P1 P2 P3 P4 P5 P6 P7 PF EEPROM error 1 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective 2 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective 3 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective 4 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective Outdoor temp. sensor or connector of temp. sensor is defective Compressor volt protection Communication error between outdoor IC and DSP Compressor discharge temp. protection High pressure protection (just for 36K 1x4 units.) Low pressure protection (just for 36K 1x4 units.) Compressor current protection Inverter module protection Outdoor temp. too low protection Condenser high-temperature protection Compressor driving protection PFC protection
15 7.3Trouble shooting Indoor unit trouble shooting Indoor unit display E0 EEPROM error Circuit or software error on indoor PCB Replace indoor PCB Indoor unit display E1 outdoor communication error Disconnect the power supply, after 1 minute, connect the power supply, turn on the unit with remote controller Does the unit work normally? Check the wiring between indoor and outdoor unit. Is the connection of L, N, S and GND good? Is the GND connection on outdoor PCB good? Reconnect and retest again Is the LED4(red) on outdoor PCB bright and LED1(yellow) blinking? Replace indoor PCB and repower on. Is the failure cleared? The power supply for outdoor PCB is fail. Check the wiring on outdoor PCB comparing with wiring plate. Is the connection good? Correct the connection. Replace outdoor e-box. Indoor unit display E2 Zero-crossing examination error
16 Is power supply and connection of connectors good? Be sure the power supply is good and correct the connection Indoor PCB is defective. Replace the indoor PCB. Indoor unit display E3 Fan speed beyond control Is the indoor fan motor connector and connection good? Repair the connector and reconnect Is voltage being applied to the fan motor? (rang 90v-160v between mid pin and N on CN1 Indoor PCB is defective. Replace the indoor PCB. Replace the indoor fan motor Indoor unit display E5 Outdoor units temp. sensor or connector of temp. sensor is defective Is the outdoor temperature sensor connector and connection good? Repair the connector and reconnect Replace the sensor and check if E5 display again? Replace outdoor e-box Indoor unit display E6 Indoor units temp. sensor or connector of temp. sensor is defective
17 Is the indoor temperature and evaporator sensor connector and connection good? Repair the connector and reconnect Replace the sensor and check if E6 display again? Replace the.indoor PCB Indoor unit display P0 Inverter module protection Is voltage normal? Revise the power and retest. Is all connection good? Revise the power and retest. Is the wiring to compressor right? Check the modular if some components blow out or be failure? Repair or replace the modular. Is it breakdown between P-N, P-V, P-W, N-V,N-W or V-W of inverter moduler? Replace the modular. Check the compressor. Indoor unit display P1 Outdoor voltage protection Is the power supply good? Be sure the power supply is normal when using the units Replace the outdoor e-box.
18 Indoor unit display P2 Compressor top protection against temperature Does compressor operate? Is the connection good? Reconnect and retest. Is refrigerant circulation volume normal? Is protector normal? Replace the protector. Charge refrigerant Check the outdoor main PCB. Is there some problem? Is abnormality the same after gas charging? Replace the outdoor PCB. Check refrigerant system (such as clogging of capillary, Indoor unit display P3 Compressor current protection The trouble shooting is same with one of outdoor unit P3 protection Outdoor unit trouble shooting Outdoor unit display E0 EEPROM error Circuit or software error on indoor Replace indoor Outdoor unit display E1 1 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective
19 Is connection to connector of pipe temp. sensor good? Check the resistance of the temp. sensor according to Annex 1 Repair connector Replace the sensor Outdoor unit display E2 2 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective Is connection to connector of pipe temp. sensor good? Check the resistance of the temp. sensor according to Annex 1 Repair connector Replace the sensor Outdoor unit display E3 3 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective Is connection to connector of pipe temp. sensor good? Check the resistance of the temp. sensor according to Annex 1 Repair connector Replace the sensor Outdoor unit display E6 4 Indoor units pipe temp. sensor or connector of pipe temp. sensor is
20 defective Is connection to connector of pipe temp. sensor good? Check the resistance of the temp. sensor according to Annex 1 Repair connector Replace the sensor Outdoor unit display E4 Outdoor units temp. sensor or connector of temp. sensor is defective Is connection to connector of pipe temp. sensor good? Check the resistance of the temp. sensor according to Annex 1 Repair connector Replace the sensor Outdoor unit display E5 Compressor volt protection
21 Check the voltage of power supply, if the voltage is about 220V, turn off the power supply to indoor unit and turn it on again after 1 minute Does the trouble occur again? Check the voltage of secondary of T3 transformer in outdoor power board, is this voltage 12-14V(AC) Replace the outdoor power board
22 Outdoor unit display E7 outdoor units communication protection Is the LED in outdoor main PCB light? Check the signal wires between outdoor PCBs, is it connected good. 1.Is the +5 voltage in outdoor main board? Power Board: CN4, Red wire and yellow (GND) Outdoor main PCB: CZ1 2.Is the +3.3v voltage in outdoor main board? Power Board: CN1, Purple wire and yellow (GND) Inverter module defective. Rectifier circuit is bad connection or defective when the voltage in outdoor is abnormal. D and N: 310V(DC); Check the IC6, IC7 (at Outdoor power PCB) rmally: Input voltage: <5V, changeable Output voltage:<5v, changeable Outdoor power PCB is defective. Outdoor unit display P0 Compressor top protection against temperature
23 Off: 105c; On: 90c The trouble shooting is same with the one of indoor unit P2 protection. Outdoor unit display P3 Compressor current protection Check the resistance of compressor, normally U and V is 1 ohm U and W is 1 ohm V and W is 1ohm The compressor is defective Turn one indoor unit only, Does the compressor start after 3 minutes? The compressor is defective Does the trouble occur again after compressor running some time? Check the refrigerant circulation volume and pressure If refrigerant circulation volume and pressure is OK, change the outdoor main PCB. Outdoor unit display P4 Compressor drive malfunction(drive protection arose)
24 Are the U,V,W connected to compressor and inverter module right? Replace the outdoor power board Repair connector If the problem comes to again, check wingding resistance of inverter compressor, is it 1 ohm? Replace inverter compressor Outdoor unit display P4(LED flashes for nine times) Compressor drive malfunction(module protection arose) Are the U,V,W connected to compressor and inverter module Replace the module to see if it is normal? Repair connector Replace the outdoor power board If the problem comes to again, check wingding resistance of inverter compressor, is it right? Replace inverter compressor Outdoor unit display
25 P6 Condenser high-temperature protection When outdoor pipe temp. is more than temp. less than 52 C (126 ) C, the unit will stop, and unit runs again when outdoor pipe Is the outdoor pipe temp. more than 65 C (149 )? Is the outdoor pipe temp sensor right according to the annex 1 Replace the outdoor main board Replace the outdoor pipe temp sensor
26 Annex 1 Characteristic of temp. sensor Temp. Resistance KΩ Temp. Resistance KΩ Temp. Resistance KΩ
27 Annex 2 1. Reference voltage data: a) Rectifier : Input : V(AC), output :310V(DC) b) Inverter module: U,V, W 3ph. Result U-V U-W V-W V(AC) V(AC) V(AC) P-N DC 31 0V c) Photo-couple PC817, PC851: Control side <+5V, AC side :< 24V(AC) d) S terminal and N: changeable from 0-24V 2. Check the Diode Bridge component ( In wiring diagram, rectifier) Remark: If this part is abnormal, the LED will not light. ~ + - ~ Multi-meter Result Forward Resistance Backward Resistance + _ Infinite Infinite ~ ~500 ohm Infinite ~ + - ~ ~500 ohm Infinite ~
SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/
SERVICE MANUAL Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/ FS2MI-147HFD FS2MI-187HFD FS3MI-217HFD FS3MI-277HFD FS4MI-277HFD FS4MI-367HFD FS5MI-367HFD NOTE: Before servicing the
More informationTechnical service manual 2009
MULTI SPLIT TYPE, HEAT PUMP AIR CONDITIONERS Technical service manual 2009 KSIM MULTI ZONE SERIES R410A DC Inverter multi Series Models KSIM20912-H216 KSIM30912-H216 KSIM40912-H216 CONTENT 1. Product features
More information13. Troubleshooting. Indoor unit s LED indication of Corona DC inverter unit. Indoor unit s LED indication of Alfa DC inverter unit
Troubleshooting 13. Troubleshooting Indoor unit s LED indication of Corona DC inverter unit MCAC-HTSM-2007-11 E0 E1 E2 E3 E5 E6 P0 P1 P2 P3 P5 EEPROM error outdoor communication error Zero-crossing examination
More informationService manual. The voltage in P3 and P4 in outdoor PCB is high voltage about 310V The voltage in P5 and P6 in outdoor PCB is high voltage about 310V
Resistance The voltage in P3 and P4 in outdoor PCB is high voltage about 310V The voltage in P5 and P6 in outdoor PCB is high voltage about 310V 9.2 Troubleshooting for indoor unit E0 E1 E2 E3 E5 E6 P0
More informationTechnical service manual
GD Midea Refrigeration Equipment Co.,Ltd ODMI-A-1202 MULTI SPLIT TYPE, HEAT PUMP AIR CONDITIONERS Technical service manual R410A Multi DC inverter 220~240V-1Ph-50Hz Outdoor units Models M2OC-14HRDN1 M2OC-14HRDN1-Q
More information10.1 Indoor Unit Error Display
10.1 Indoor Unit Error Display Display E0 E1 E2 E3 E5 E6 P0 P1 P2 P4 LED STATUS EEPROM parameter error Indoor / outdoor units communication protection Zero-crossing signal error Fan speed out of control
More information14. Troubleshooting Guide
14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include
More informationR22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power
R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor
More informationFailure code manual. content
Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一
More informationHaier Air conditioner
For Europe Haier Air conditioner HAND in HAND HIGHER and HIGHER Page:1 For Europe HSU-09/12HVA103/R2(DB) HSU-09/12RHA103/R2(DB) Page:2 Error Codes and Description indoor and outdoor display(1) indoor Code
More informationLG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
More informationLG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems
Universal Split Systems If there is a fault on any LG Universal unit, a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller the fault will
More informationModel: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0
Air Conditioner Service Manual 2 3 Model: AC-S13CG x 2 3 Content Technical specification.. 4 Performance curve.5 Outline & dimension of indoor unit..10 Outline & dimension of outdoor unit 11 Exploded view
More informationSERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS
More informationSERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF ASU5RLS AOU 9RLFW AOURLFW AOU5RLS R40A CONTENTS. DESCRIPTION OF EACH CONTROL
More informationMidea Commercial Air Conditioner Malfunction Handbook
Midea Commercial Air Conditioner Malfunction Handbook May 1, 2008 Customer Service Philosophy of Midea Air Conditioner Service Target: 100% Customer Satisfaction Service Standard: 100% Earnestness Service
More informationSERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2
SERVICE MANUAL Room Air Conditioner Multi Split Wall-Mounted Type Indoor FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2 NOTE: Before servicing the unit, please read this at first. Always contact with
More informationSERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER
More informationRMI-1103-A SERVICE MANUAL MIDEA AIRCONDITIONER EUROPE MARKET DC INVERTER MULTI TYPE R DC INVERTER MULTI SERIES
RMI-1103-A SERVICE MANUAL MIDEA AIRCONDITIONER EUROPE MARKET DC INVERTER MULTI TYPE R DC INVERTER MULTI SERIES CONTENTS 1. Precaution... 1 1.1 Safety Precaution... 1 1.2 Warning... 1 2. Function... 6 3.
More informationService manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
More informationSERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT
More informationRepair Guideline for TCL DC Inverter Air Conditioner
Repair Guideline for TCL DC Inverter Air Conditioner FLOS SERIE---V3 0 CONTENTS Ⅰ. Introduction of New control board for outdoor unit...2 1. The structure of control board... 2 2. Diagram of outdoor unit........4
More informationIndoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty
Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp
More informationCONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6.
TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE051220 Models TAC-09CHSA/GI TAC-12CHSA/GI CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM
More informationMP-4000 Alarm List (Software version 2.4.3 or later)
Service Bulletin SUBJECT: MP4000 Alarm s BULLETIN: C 100 DATE: June 19, 2013 ALARM LIST Where it is possible the alarm number is kept the same as for MP-3000. MP-3000 holds alarm number from 0 to 127.
More informationPANASONIC TROUBLE SHOOTING GUIDE
A General Guide To Room Style Products Pipework Pipe sizes and lengths should be as the relevant Technical Guide Both lines should be insulated No line accessories or oil traps should be fitted In cooling
More informationAir conditioning, electrical testing
just a test. Air conditioning, electrical testing 01-253 Wire and component test using VAG1598 A test box Special tools and equipment VAG 1598 A test box and VAG 1598/11 adapter cable and VAG 1598/12 VAG1526
More informationNO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS
INFORMATION INFORMATION ON THE TECHNOLOGY The -Frost refrigerators are different from the other static refrigerators in terms of their operational system. In normal refrigerators, in the freezing section,the
More informationTechnical Information
Date of last update: Oct-11 Ref: D7.8.4/1011/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS CoreSense Diagnostics for Stream Refrigeration Compressors... 1
More informationsip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved
Sanyo Section : Section : Section : Section : Section : sip Modbus Guide Configuration Modbus Table Technical Specification Pinouts, Cable Connections & Wiring Alarm Fault Codes Issue : February 009 Section
More informationSplit and Multi Split air conditioners Service information
Split and Multi Split air conditioners Service information Programming LG wired controllers 2 New type 2 Old type 7 Fault codes 9 Wall units (single split) 9 Universal split and multi split 10 Detailed
More information543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
More informationSERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC
SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED
More informationAppendix - Controllers 179
Version: 200703 Appendix - Controllers 179 -3- -4- -5- -6- -7- -8- 2. Specifications 2.1 Specifications for inverter units item Model AB182ACERA Function cooling heating Capacity kw 5.01.8--5.8 5.22.0---6.2
More information1 4. 3 4-2 ABNORMAL OPERATION. 4-2-1 Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target
4-2 ABNORMAL OPERATI 4-2-1 An is represented by 3 digit characters. The first 2 digit means the subsection, and the last 1 digit means the specifics. Ex.) Indoor unit Network communication Error Subsection
More informationSERVICE MANUAL MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUZ-GE18NA MUZ-GE24NA MUY-GE09NA MUY-GE12NA MUY-GE15NA MUY-GE18NA MUY-GE24NA OUTDOOR UNIT
SPLIT-TYPE AIR CONDITIONERS Revision B: Descriptions regarding the outdoor fan motor have been corrected. Please void OBH549 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH549 REVISED
More informationSERVICE MANUAL MUZ-FE09NA MUZ-FE12NA MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-A. Models HFC
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FE18NA has been added. Please void OBH543. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH543 REVISED EDITION-A Models MUZ-FE09NA MUZ-FE12NA MUZ-FE18NA Indoor
More informationVSI-1104-A SERVICE MANUAL MIDEA AIRCONDITIONER DC INVERTER SPLIT WALL-MOUNTED TYPE. Vertu SERIES
VSI-1104-A SERVICE MANUAL MIDEA AIRCONDITIONER DC INVERTER SPLIT WALL-MOUNTED TYPE Vertu SERIES CONTENTS 1. Precaution... 1 1.1 Safety Precaution... 1 1.2 Warning... 1 2. Function... 6 3. Dimension...
More informationFILE NO. SVM-07013 11. HOW TO DIAGNOSE THE TROUBLE
FILE. SVM-070. HOW TO DIAGSE THE TROUBLE The pulse motor circuits are mounted to both indoor and outdoor units. Therefore, diagnose troubles according to the trouble diagnosis procedure as described below.
More informationSi10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI
Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner
More information01-3 0000-00 6810-20 AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS 2004.09
0000-00 01-3 6810-20 1. FFH SPECIFICATION 01-4 0000-00 2. SYSTEM LAYOUT AND COMPONENTS 0000-00 01-5 01-6 0000-00 3. FFH GENERAL INFORMATION The system is to increase the coolant temperature quickly by
More information9ASNA-A1-1202 SERVICE MANUAL SENVILLE AIRCONDITIONER DC INVERTER SPLIT WALL-MOUNTED TYPE
9ASNA-A1-1202 SERVICE MANUAL SENVILLE AIRCONDITIONER DC INVERTER SPLIT WALL-MOUNTED TYPE CONTENTS 1. Precaution... 1 1.1 Safety Precaution... 1 1.2 Warning... 1 2. Function... 6 3. Dimension... 9 3.1 Indoor
More informationTHERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.
THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS. NOT ALL CODES ARE POSSIBLE ON ANY INDIVIDUAL UNIT. IF THE ALARM APPLIES
More informationHP switch LP switch Discharge thermo Comp. Surface thermo
1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer
More informationCONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM 13 5. EXPLOSION VIEW 16 6
TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE080528 Models KFTHP-12 KFTHP-18 KFTHP-24 CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL
More informationA/C-HEATER SYSTEM - AUTOMATIC
A/C-HEATER SYSTEM - AUTOMATIC 1995 Volvo 850 1995-96 Auto. A/C-Heater Systems Volvo 850 * PLEASE READ THIS FIRST * WARNING: To avoid injury from accidental air bag deployment, read and carefully follow
More informationLG Checkpoint-codes. Versie 2.4P-M vervangt U02.3.M
LG LG Checkpoint-s Versie 2.4P-M vervangt U02.3.M BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THE SERVICEMANUAL. ONLY FOR AUTHORIZED SERVICE PERSONNEL. 1 Hoofdstukindeling Single A (vloer-
More information*.ppt 11/2/2009 12:48 PM 1
Digital Compressor Controller *.ppt 11/2/2009 12:48 PM 1 Copeland Scroll Digital Controller Simple Controller That Enables OEM s To Use Digital Scrolls Relieves OEM From Developing Special Controllers
More informationALL IN ONE. Heat Pump Water Heater
ALL IN ONE Heat Pump Water Heater INSTALLATION AND OPERATION INSTRUCTIONS Please read this user s manual carefully before operate the unit. www.airtradecentre.com CONTENTS A. IMPORTANT REMARKS ------------------------------------------------------------------------------------------------
More informationSERVICE MANUAL MIDEA AIRCONDITIONER DC INVERTER SPLIT WALL-MOUNTED TYPE MSV1-09HRDN1-QC2(A) MSV1-12HRDN1-QC2(A)
SERVICE MANUAL MIDEA AIRCONDITIONER DC INVERTER SPLIT WALL-MOUNTED TYPE MSV1-09HRDN1-QC2(A) MSV1-12HRDN1-QC2(A) V1.2 Oct, 2007 CONTENTS 1. Precaution... 1 1.1 Safety Precaution... 1 1.2 Warning... 1 2.
More informationDC INVERTER MULTI-SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : AEMI0AH AEMIAHB AEMIAH AEMI0AH FILE NO. Destination: Europe DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity.0k.k.k.0k Outdoor Model No. AEMI0AH AEMIAHB AEMIAH
More informationAir Conditioning System
Air Conditioning System 1 Chonan Technical Service Training Center Chonan Technical Service Training Center 2 Objectives To understand the components of air conditioning system. To understand the control
More informationSERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY
SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY! WARNING - SHOCK HAZARD! TO PREVENT THE POSSIBILITY OF SEVERE PERSONAL INJURY, DEATH, OR EQUIPMENT DAMAGE DUE TO ELECTRICAL
More informationSERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH
More informationRepair Guideline for TCL DC Inverter Air Conditioner
Repair Guideline for TCL DC Inverter Air Conditioner Contents I. Electrical Control of Inverter Air Conditioner 2 1. Main compositions of the electrical control of inverter air conditioner 2 2. Wiring
More informationWYS SERIES SPLIT 3D DC INVERTER HEAT PUMP / AIR CONDITIONER SERVICE MANUAL
z WYS SERIES SPLIT 3D DC INVERTER HEAT PUMP / AIR CONDITIONER SERVICE MANUAL Revision A: 151110001, Content updated. Model Numbers: 17 SEER Family: WYS009AMFI17RL, WYS012AMFI17RL, WYS009GMFI17RL, WYS012GMFI17RL,
More informationtechnical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air
technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t
More informationSERVICE MANUAL REFRIGERATION
SERVICE MANUAL REFRIGERATION ELECTROLUX HOME PRODUCTS S.p.A. Publication no. Spares Operations Italy 599 36 16-90 Corso Lino Zanussi, 30 031117 I - 33080 PORCIA / PN (ITALY) ITZ/SERVICE/AA Fax +39 0434
More informationElectronically Controlled Clutchless or Variable Drive Compressors
Electronically Controlled Clutchless or Variable Drive Compressors On many new air conditioning systems, such as Lexus, Cadillac, Chrysler, and others, a new type of compressor has been fitted. There are
More informationSERVICE MANUAL. Room Air Conditioner Split Wall-Mounted Type. FSAI-Pro-91AE2 / FSOAI-Pro-91AE2. FSAI-Pro-241AE2 / FSOAI-Pro-241AE2
SERVICE MANUAL Room Air Conditioner Split Wall-Mounted Type FSAI-Pro-91AE2 / FSOAI-Pro-91AE2 FSAI-Pro-121AE2 / FSOAI-Pro-121AE2 FSAIF-Pro-181AE2 / FSOAIF-Pro-181AE2 FSAI-Pro-241AE2 / FSOAI-Pro-241AE2 NOTE:
More informationRepair Guideline for SANYO New Erp. DC Inverter Air Conditioner (Published in May, 2013)
Repair Guideline for SANYO New Erp DC Inverter Air Conditioner (Published in May, 2013) Contents I. Electronic Control of DC Inverter Air Conditioner 2 1. Main parts of the electronic control of DC inverter
More informationTECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation
More informationUser Manual for CH-PFC76810
AA Portable Power Corp www.batteryspace.com, Email: Sales@batteryspace.com User Manual for CH-PFC76810 1. Overview The CH-PFC76810 charger is suitable for charging lithium ion battery packs such as those
More informationAIR CONDITIONER OUTDOOR UNIT. Product Specifications. Disassembly and Reassembly. Troubleshooting. PCB Diagram. Wiring Diagram.
SYSTEM AIR CONDITIONER OUTDOOR UNIT AM036FXMDCH AM048FXMDCH AM053FXMDCH AIR CONDITIONER CONTENTS Product Specifications Disassembly and Reassembly Troubleshooting PCB Diagram Wiring Diagram Reference Sheet
More informationCondensing unit type EPSILON-ECHOS LE Technical information manual
Condensing unit type EPSILON-ECHOS LE Technical information manual 2 > EPSILON ECHOS Water chiller > EPSILON ECHOS /HP Reversible heat pump > EPSILON ECHOS /ST Water chiller with storage tank and pumps
More informationTechnical Service Manual. Version One
[Gree Central Air Conditioner] Technical Service Manual Ducted type unit 2.3KW-16KW Version One GREE ELECTRIC APPLIANCES.INC.OF ZHUHAI - 1 - FG Series wind pipe blowing air-conditioning unit Section One:
More informationSIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND
Honeywell Electronic Ignition Troubleshooting Tech Tip April 2007 The Honeywell S8610H Intermittent Pilot Module provides the ignition sequencing, pilot spark, pilot flame monitoring, Pilot Valve (PV)
More informationDC INVERTER MULTI-SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CM97 CM7 CM7 FILE NO. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 9,700 BTU/h,00 BTU/h 0,600 BTU/h Outdoor Model No. CM97
More informationDC INVERTER SPLIT SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL SAP-KRV9AEH + SAP-CRV9AEH SAP-KRV12AEH + SAP-CRV12AEH FILE NO. Destination: Europe DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. SAP-KRV9AEH SAP-KRV12AEH Product
More informationPanel Mounted Air Conditioners by Dantherm, Inc.
Panel Mounted Air Conditioners by Dantherm, Inc. CS020020A/B with USACG-6 Control PRODUCT INFORMATION MANUAL AC-2 CS020020 USACG-6 Manual Rev H Page 1 of 17 Dantherm, Inc. 110 Corporate Drive, Suite K
More informationChapterⅠ Introduction to Products
AI RCONDI TI ONI NG SYSTEMS Model s : UMATCH I NVERTER Ser vi cemanual Ser vi cemanual ChapterⅠ Introduction to Products 1. Kinds of Products Universal outdoor unit Duct type Floor ceiling type Cassette
More informationCommercial Refrigeration Temperature and Defrost Controls
Commercial Refrigeration Temperature and Defrost Controls UNI-LINE PRODUCT KNOWLEDGE 2010 Invensys. All Rights Reserved. The names, logos, and taglines identifying the products and services of Invensys
More informationINSTALLATION MANUAL. Address card EKAC10B
INSTALLATION MANUAL 88 44 µchiller compact 70 64 4a 4b G G0 power supply G G0 power supply 50 5 50 5 4a 4b 5a 5b 4 5a 5b Installation manual READ THIS MANUAL ATTENTIVELY BEFORE STARTING UP THE UNIT. DO
More informationSimple Self-Diagnosis by Malfunction Code
Simple Self-Diagnosis by Code After Sales Service Division (SM-TS2) Detail Division 0 Indoor Unit System Others A C E F H J L P U M 7 8 9 External device activated (unified) Protection devices activated
More informationAUTOMATIC CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM
SECTION 7D AUTOMATIC CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM TABLE OF CONTENTS Description and Operation... 7D- General... 7D- FATC Control... 7D- FATC Input/Output Routing Diagram...
More informationInstruction manual for Firstline FCS12000CH
Instruction manual for Firstline FCS12000CH Contents Introduction... 2 Safety Awareness... 3 Safety Awareness... 4 Name of Parts... 5 Name of Parts... 6 Remote Controller Preparation... 7 Operation of
More informationMAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R. www.heating.danfoss.com
MAKING MODERN LIVING POSSIBLE Wiring Diagram www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English
More informationTable Z. Troubleshooting Chart for Air Conditioners. Cause
Troubleshooting Chart for Air Conditioners Type of Unit Complaint Cause With open-type compressor Electric motor will not start Power failure Check circuit for power source Compressor stuck Locate cause
More informationTankless Gas Water Heaters Second Generation Indoor, Outdoor and Direct Vent Up to 199,000 BTU
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Tankless Gas Water Heaters Second Generation Indoor, Outdoor and Direct Vent Up to 199,000 BTU Includes RTG2-42, RTG53, RTG66 and
More informationThermo Top - Troubleshooting Tree
Thermo Top - Troubleshooting Tree 07-15-2002 CAUTION Troubleshooting requires comprehensive knowledge about the structure and theory of operation of the Thermo Top heater. Troubleshooting and repairs may
More informationSplit units TH with hermetic compressors
Split units TH with compressors Refrigeration units in split variant. Available with screw or solder terminal. Condensing unit with sound insulated weatherproof housing for outdoor installation. Split
More informationSERVICE MANUAL AE-X2M14LR MULITI SPLIT TYPE ROOM AIR CONDITIONERS (OUTDOOR UNIT) MODEL. No. S2038AEX2MLRT CONTENTS AEX2M14LR
TopPage AEX2M14LR SERVICE MANUAL. S2038AEX2MLRT MULITI SPLIT TYPE ROOM AIR CONDITIONERS (OUTDOOR UNIT) MODEL AE-X2M14LR In the interests of user-safety (Required by safety regulations in some countries)
More informationSERVICE MANUAL MUZ-HJ25VA MUZ-HJ35VA OUTDOOR UNIT. No. OBH648. Models HFC SPLIT-TYPE AIR CONDITIONERS R410A
SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. Models MUZ-HJ25VA MUZ-HJ35VA - E1 - E1 Indoor unit service manual MSZ-HJ VA Series (OBH647) MUZ-HJ25VA MUZ-HJ35VA CONTENTS 1.
More informationTECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER + SAP C181MA + SAP C181GA + SAP C181BA + SAP C241MA + SAP C241BA FILE NO.
TECHNICAL & SERVICE MANUAL SAP K161GJA SAP K181GJA SAP K181MBA SAP K241GJA SAP K241MBA + SAP C161GA + SAP C161JA + SAP C181GA + SAP C181JA + SAP C181MA + SAP C181BA + SAP C241GA + SAP C241JA + SAP C241MA
More informationDC INVERTER MULTI-SYSTEM AIR CONDITIONER
AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL INDOOR UNIT : CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU CS-MKE18NKU CS-MKE24NKU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 7,500BTU / h 9,000BTU
More informationSERVICE MANUAL INDOOR UNIT
SPLIT-TYPE AIR CONDITIONERS Revision E: MSZ-GE22VAD- A1 has been added. Please void OBH531 REVISED EDITION-D. INDOOR UNIT SERVICE MANUAL. OBH531 REVISED EDITION-E Models MSZ-GE22VA - A1 MSZ-GE50VA - A1
More informationDC INVERTER SPLIT SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL CSKS12NB41 & CZ18BT1U + CUKS12NK1A CSKS18NB4UW & CZ18BT1U + CUKS18NKU CSKS18NB4UW & CZ18BT1U + CUKS18NKUA DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel)
More informationSERVICE MANUAL INDOOR UNIT
SPLIT-TYPE AIR CONDITIONERS Revision B: "How to check miswiring and serial signal error" for MUZ type has been added. The description about "Low standby power control" has been added to "TECHNICAL CHANGES".
More informationWALL MOUNTED AIR CONDITIONER SERVICE MANUAL 11M INVERTER
WALL MOUNTED AIR CONDITIONER SERVICE MANUAL 11M INVERTER This manual applies to the models: 42HVM109303 / 38HVM109303(P) 42HVM112303 / 38HVM112303(P) 42HVM118303 / 38HVM118303(P) 42HVM124303 / 38HVM124303(P)
More informationXIV. Electrical / Electronics
Mobile Climate Control 261 MCC Reference Manual 2014 Temperature Controllers Mini Vehicle Controller P/N: 35-0748 P/N: 35-8071 Specifications Operating Voltage: Operating Temperature: Inputs: Outputs:
More informationSERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications
More informationHeater and Air Conditioner, Blend Air System, Troubleshooting 83.06
A/C Performance Diagnosis Problem Warm Airflow When the Air Conditioner is On, A/C Not Working, or Poor A/C Performance (dash outlet temperature is too high) Problem Warm Airflow When the Air Conditioner
More informationHITACHI INVERTER-DRIVEN MULTI-SPLIT SYSTEM HEAT PUMP AIR CONDITIONERS
HITACHI INVERTER-DRIVEN MULTI-SPLIT SYSTEM HEAT PUMP AIR CONDITIONERS SET FREE FSG(1)/FS3, FS5 SERIES AND SET FREE FXG/FX3 SERIES Models In-the-Ceiling Type RPI-0.8FSG1 RPI-2.5FSG1 RPI-8FSG1
More informationUser Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com
Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com Document updates: Version Data Description V1.0 2015.05.25 Finish new document HVAC Controller User Manual INDEX 1. Overview...1
More informationA4 Air Conditioning Control Circuit Troubleshooting Rev 7, 6/18/2009
A4 Air Conditioning Control Circuit Troubleshooting Rev 7, 6/18/2009 ** This guide is for Manual Air Conditioning (as opposed to Climatronic A/C or Climatic A/C), with two 2-speed fans on Volkswagen A4's
More informationBITMAIN. APW3-12-1600 PSU Series User Guide
BITMAIN APW3-12-1600 PSU Series User Guide Contents 1 Overview... 3 2 Features... 3 3 Specifications... 4 4 Switching On/Off Remotely... 5 5 Order Information & Wire Type... 6 5.1 Order Information...
More informationNSN 4120-01-21 4-3692
*TM 9-4120-388-14 TECHNICAL MANUAL Operator s, Unit, Direct Support, And General Support Maintenance Manual AIR CONDITIONER, VERTICAL, COMPACT, 18,000 BTU/HR 208 VOLT, 3 PHASE, 50/60 HERTZ NSN 4120-01-21
More informationSERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY
RV Products Division SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY Airxcel, Inc. RV Products Division P.O. Box 4020 Wichita, KS 67204 1976A376 (1-11) TABLE OF CONTENTS
More informationHeat Pump Water Heater IOM Manual
Heat Pump Water Heater IOM Manual Installation Operation & Maintenance This manual is intended as an aid to qualified service personnel for proper installation, operation and maintenance of the heat pump
More informationINSTALLATION & SERVICE MANUAL. Display Panel
INSTALLATION & SERVICE MANUAL Display Panel The PowerLine EMS TM is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed
More information