McDaniel. All Stainless Gauges 1 1 /2", 2", 2 1 /2", 4" and 6" Safe Accurate Reliable Durable

Size: px
Start display at page:

Download "McDaniel. All Stainless Gauges 1 1 /2", 2", 2 1 /2", 4" and 6" Safe Accurate Reliable Durable"

Transcription

1 cdaniel All tainless auges 1 1 /2", 2", 2 1 /2", 4" and 6" afe Accurate Reliable Durable Ranges: Pressure, Vacuum, ompound, Receiver 3-15 PI 1.6 inches of water column up to 60,000

2 cdaniel All tainless teel auges 1 1 /2, 2, 2 1 /2, 4 and 6 eatures All tainless onstruction Laminated afety lass Lens Blowout Relief rommet illable ase Accuracy: *1.5% on 1 1 /2 gauges - AE B.1 rade A *1% on 2 and 2 1 /2 gauges - AE B.1 rade 1A * 1 /2% on 4 and 6 gauges - AE B.1 rade 2A (*,000 PI and below) Adjustable pointer standard on 4 and 6 only afe and Reliable cdaniel designs and manufactures its gauges to minimize failure and to protect personnel and property. The use of laminated safety glass, rather than plexiglass or single strength glass, prevents dangerous pressure build-up in the case; the 2 glass breaks at 60, the 2 1 /2 at, the 4 at 15 and the 6 at 8. The brittle glass cracks uniformly and the laminate remains intact. Additionally, the laminated safety glass won't craze or discolor. Every All tainless teel cdaniel gauge is designed to withstand: 300% full scale pressure without rupture of the bourdon tube. 130% full scale pressure without loss of accuracy. 15,000 cycles of pressure pulsation from % to % full scale at a rate of 60 times a minute. The gauge is allowed to rest for 5 minutes and then can have no greater error than 1% above it s original accuracy as stated above; at any place on the dial. Pulse/Vibration Protection cdaniel offers liquid-filled gauges for applications involving vibration or pulsation. lycerin is an excellent damper of bourdon tube movement. Emersion of the entire measuring assembly in a protective liquid envelope provides lubrication and shuts out corrosive or dirty atmospheres thereby minimizing wear of moving parts and prolonging gauge life significantly. hoice of illing When you order a cdaniel fillable gauge you may choose to fill it yourself or you may order it factory-filled with the liquid of your choice. Thus, you can maximize inventory utility and minimize inventory cost. lycerin filling has a lower operating temperature limit of 32 0 (0 0 ) undiluted. The mixture of distilled water in proportions up to 35% will lower the limit commensurately, to 0 (- 0 ). ilicone can extend the lower temperature limit to 60 0 (-50 0 ). The maximum temperature limit is not determined by the fluid but by the gauge's synthetic case seal. At elevated temperatures the seal may bake and lose its elasticity. Warning: lycerin filled gauges should not be used in applications involving strong oxidizing agents such as chlorine, nitric acid or hydrogen peroxide. (Refer to AE B.1) Repair eature If any cdaniel gauge requires repair, downtime can be minimal because all gauges are field-repairable quickly and easily with only a screwdriver needed for disassembly. If circumstances permit and factory repair is preferred, we will make the repair at a nominal service charge. ee "WARRANTY & REPAIR" for further details. Warranty cdaniel warrants our pressure gauges to be free of defects in material and workmanship: Replacement of any defective gauge will be made at no cost to the purchaser. auge failures determined to be caused by abuse, over-range and incompatibility with environment or process media will not be considered under this warranty. Repair / Refurbish We will repair any regular stock cdaniel gauge for a cost of $15.00 on 4 and 6 sizes; $7.50 on 2 ¹ ₂ and smaller (excluding Utility auges). Damaged sockets or bourdon tubes cannot be repaired. (pecial Units, contact cdaniel for pricing) Prices are.o.b. Boutte, Louisiana U..A.

3 ase tyles 1 1 /2 () illed or illable odel - 1 /8 NPT* *TANDARD Also available in 1 /4 NPT on Request. (enter-back onn. Only) 2 (50) illed or illable odel Q3-1 /4 NPT* *TANDARD Also available in 1 /8 NPT on Request. 2 1 /2 (63) illed or illable odel K Range election * - 1 /4 NPT* *TANDARD Also available in 1 /8 NPT on Request. hoice of ounting tyle ountings are specified by using the following suffixes as codes: P = Panel mount/center-back connection (odels and Q3) Panel mount/lower-back connection (odels A,, E,, B, D,,, K) L = Lower-back connection* (odels A,, E,, B, D,,, K) enter-back connection (odel ) 1 = enter-back connection odel Q3 only U = U-lamp for panel mounting (enter-back on and Q3) R = Rear flange for wall mounting (2 1 /2, 4" and 6" gauges only) (odels A,, E,, B, D,,, K) ( 1 odel Q3 center-back connection uses to denote center-back connection not L ) 4" (0) Non-illable odel A - 1 /4 NPT odel - 1 /2 NPT 4 (0) illed or illable odel E - 1 /4 NPT odel - 1 /2 NPT 6 (160) Non-illable odel B - 1 /4 NPT odel D - 1 /2 NPT 6 (160) illed or illable odel - 1 /4 NPT odel - 1 /2 NPT * 1.6" inches of water column to 250" wc available. To order wc, mercury or other pressure calibrations, describe desired range, (rather than use a range code) after specifying code for case size. Range ode Range () Range ode Range () N 0 3, O 0 5, k 0 6,000 0 P 0,000 A 0 15 Q 0 15,000 B 0 30 R 0, k 0 30,000 D k 0 35,000 E " g 0 Vacum 0 0 T Receiver U ompound 30"g V ompound 30"g-0-30 I W ompound 30"g-0-60 J 0 0 X ompound 30"g-0-0 K 0 1,000 Y ompound 30"g L 0 1,500 2k ompound 30"g ,000 Z ompound 30"g pecial onfiguration Adder odes B = /Bar (dual scale) K = /kpa (dual scale) O = O2 (cleaned for oxygen service) = olid front/blow-out back case (2 1 /2, 4" & 6" gauges only) = odel K available with center-back connection by special order for ranges. (* inches of water column ranges, 4 inch dial models A &, have center-back connection and still use L to designate, not )

4 hoice of ounting tyle tandard olid ront/ Bottom onnection Blow-out Back () Rear lange (R) U-lamp ront lange Panel ount (U) Back onnection (L) Panel ount (P) hoice of cale cdaniel offers from inventory many dual scale ranges. These include /kpa with the scale primary and kpa secondary; /Bar with the scale primary and Bar secondary; /kg/cm 2 with primary and kg/cm 2 secondary; kg/cm 2 / with kilograms per cm 2 primary and secondary. A word about Non-tandard Ranges: cdaniel offers more ranges and special calibrations than any other manufacturer of gauges for only a nominal charge if any. onsult your cdaniel distributor. ow to Order by ode Number 1. elect case style. 2. elect pressure range (Describe if requesting inches of water column, mercury, etc.). 3. Add mounting style if other than a standard bottom connection. 4. Add special configurations if needed either by code or by written description. 5. Add choice of filling, if appropriate: ( = lycerin illed, = ilicone illed, or = luorolube illed) Example: Range Type of pecial Type of odel ode ounting onfiguration illing E 6k P Order: A 4" sealed gauge with a scale of , panel mounted/lower-back 1 /4 NPT connection, filled at the factory with glycerin (E6kP-).

5 A B 2¹ ₂, 4 and 6 D E Durable The best-known construction materials available are used in the manufacture of cdaniel gauges: A. 304 tainless teel eavy Duty ase B. 316 tainless teel eavy Duty ovement. 316 tainless teel eavy Duty onnection, ocket and Bourdon Tube D. Neoprene askets E. Laminated afety lass Lens. Polished 304 tainless teel Bayonet Ring piral Bourdon Tube Bourdon tube work hardening can cause premature rupture in a pulsation type service, especially if that service is above 0, where heavy wall thickness of the Bourdon tube is encountered. piral Bourdon tube (annealled) Pointer shaft tainless sector gear Vacuum top All tainless teel movement link pan adjustment ovement mounting screws ase attachment screw hole tem gasket Threads rolled, not cut cdaniel, therefore, incorporates an annealled spiral bourdon tube as the sensing element of all gauge ranges above 0 to minimize bourdon tube failure possibilities.

6 Dimensional Data B AND OKET c Daniel A ontorls 0 30 AND OKET c Daniel A ontorls T U-lamp L AND OKET c Daniel Back onnect A ontorls L I A J 15 0 AND OKET c Daniel ontorls K N L Bottom onnection D Nominal ase odel ize Diameter 1¹ ₂ In. Q3 2 In. K 2¹ ₂ In. A,, E, 4 In. B,D,, 6 In. K t 2¹ ₂ In. E, t 4 In., t 6 In. E A B D E I J K L N P T B 16 (1) B (2) B.5 (6) B (7) (3) (4) (5) B B t olid ront Blow-out Back ase (1) 30, 60, 0 PI range = 13.5, (0.53 Inches) (4) 1 /4 NPT = 15 (.059 Inches) (7) 1 /2 NPT = 43 (1.69 Inches) B enter-back connection only (2) 1 /8 NPT = 45 (1.77 Inches) (5) 1 /4 NPT = 36 (1.42 Inches) B Bottom ount connection only (3) 1 /4 NPT = 1 (4.33 Inches) (6) 1 /8 NPT = 16.5 (0.65 Inches) cdaniel also makes gauges in other materials, in sizes and ranges to fit a wide variety of applications, and in many special configurations. P D odels & Q3 are enter-back = (*inches of water ranges, 4 dial models A & are center-back) Ask your representative about cdaniel gauges with brass internals, gauges with Polyamid B cases, all brass gauges, test gauges, or other requirements. DITRIBUTED BY P Panel ount D P P. O. Box 187, Luling, LA U..A ighway, Boutte, LA U..A. (985) New Orleans (504) ax (985) cdaniel ontrols, A 3

SOLFRUNT Pressure Gauges and Other Products for the Process Industries

SOLFRUNT Pressure Gauges and Other Products for the Process Industries A1 SOLFRUNT Pressure Gauges and Other Products for the Process Industries AMETEK s line of high quality process gauges are specifically designed to meet the demanding needs of the chemical and petroleum

More information

Many Products...One Source

Many Products...One Source PRESSURE GAUGES Dedicated Sales Rep for Your Area 97%Fill Rate Shipping within 24 Hours State of the Art Warehouse System Technical Support Quality Control Program 25 Whaley Avenue Milverton, Ontario N0K

More information

WIKA INSTRUMENT CORPORATION

WIKA INSTRUMENT CORPORATION WIKA INSTRUMENT CORPORATION Instruction Manual GAUGE PRESSURE INDICATOR Series 1500 Series 1000 Series 300 WIKA Instrument Corporation 1000 Wiegand Boulevard Lawrenceville, GA 30043 1-888-945-2872 http://www.wika.com

More information

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS EPP - 1 DECRIPTION The odel 575 is used in general water/wastewater applications. The transmitter is offered in a standard non-clogging snub nose end, flush diaphragm or protected flush diaphragm with

More information

Commercial / HVAC / Plumbing. Specification Guide. For. Pressure & Temperature Instruments & Related Accessories

Commercial / HVAC / Plumbing. Specification Guide. For. Pressure & Temperature Instruments & Related Accessories Commercial / HVAC / Plumbing Specification Guide For Pressure & Temperature Instruments & Related Accessories Prepared for Consultant, Design & Specification Engineers Gauges Contractor Gauge (PCT, PCT-LF)

More information

Part I - Installation

Part I - Installation 400 Series Pressure and Differential Pressure Switches Types: H400, H402, H403, H400K, H402K, J400, J402, J403, J400K, J402K UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please read

More information

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual

More information

HVAC/R GAS TEST GAUGES SPECIFICATIONS ACCURACY CASE SIZES CASE MATERIAL MOUNTING STYLE HOUSING MATERIAL TUBE & SOCKET MOVEMENT RANGES DIAL STANDARD

HVAC/R GAS TEST GAUGES SPECIFICATIONS ACCURACY CASE SIZES CASE MATERIAL MOUNTING STYLE HOUSING MATERIAL TUBE & SOCKET MOVEMENT RANGES DIAL STANDARD HVAC/R GAS TEST GAUGE Hex or Bell Type mounting 5 to00 Psi pressure ranges Steel case and brass internals Use to pressure test all new gas installations for leaks and passing inspection codes. After installing

More information

Powers Controls TH 192 S Single Temperature Room Thermostat

Powers Controls TH 192 S Single Temperature Room Thermostat Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional

More information

POWER GEAR SLIDE OUT MANUAL

POWER GEAR SLIDE OUT MANUAL POWER GEAR SLIDE OUT MANUAL Operation Guide FLUSH FLOOR SLIDE OUT SYSTEM FOR AMERICAN COACH PRODUCTS 82 S0220 01 Rev. 1 AMERICAN COACH SLIDE OUT MANUAL FLUSH FLOOR SYSTEM TABLE OF CONTENTS SECTION PAGE

More information

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Powers Controls TH 192 HC Heating/Cooling Room Thermostat Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional

More information

Fittings, Tubing & Nipples

Fittings, Tubing & Nipples s, Tubing & Nipples P Series Pipe s s to 15,000 psi (1034 bar) Since 1945 Parker utoclave Engineers has designed and built premium quality valves, fittings and tubing. This commitment to engineering and

More information

MP-4V Heavy Duty Riveter / 39048

MP-4V Heavy Duty Riveter / 39048 MP-4V Heavy Duty Riveter / 39048 This newly designed heavy-duty air/hydraulic riveter is ergonomically designed with the professional in mind. The light weight 3.7 lbs. well balanced MP-4V includes a Vacuum

More information

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This

More information

Accu-Switch Instruction Booklet The Direct Drive Difference in Switch Gauges

Accu-Switch Instruction Booklet The Direct Drive Difference in Switch Gauges Accu-Switch Instruction Booklet The Direct Drive Difference in Switch Gauges INTRODUCTION The Accu-Switch series of pressure Switch Gauges from 3D Instruments offers a new standard for a mechanical pressure

More information

Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9

Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9 Pumping Systems, Intensifiers, Gas Boosters and High Pressure Generators High Pressure Equipment Company produces a number of components and systems for general industrial, elevated pressure applications.

More information

!"" #$% "!&' ( ( ) *

! #$% !&' ( ( ) * !"" #$% "!&' (( ) * G Whiz Gas Popper Instruction Manual Model #5908 Part No. 74874 Revised October 1997 Cincinnati, OH 45241-4807 USA GAS SAFETY PRECAUTIONS Instructions on what to do when a user smells

More information

AIR LINE VALVES AND GAUGES

AIR LINE VALVES AND GAUGES AIR LINE VALVES AND GAUGES INGERSOLL-RAND AIR LINE VALVES AND GAUGES Maintaining consistent air pressure throughout the entire system is crucial for maximum performance and productivity. Ingersoll-Rand

More information

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS Products Include: 60 gpm eductors Style 3060, 3061, 3062 & 3070 95 gpm eductors Style

More information

Bearing Failure: Causes and Cures

Bearing Failure: Causes and Cures Bearing Failure: Causes and Cures bearing.ppt Page 1 Excessive loads usually cause premature fatigue. Tight fits, brinelling and improper preloading can also bring about early fatigue failure. The solution

More information

79 GAUGE / THERMOMETER H N O

79 GAUGE / THERMOMETER H N O 79 GAUGE / TERMMETER plastic-housing 80 A 100 - D 40 Centre back entry and are not aggressive to copper alloys. Design: E 837-1. Case: black plastic. Dial: white plastic. Window: clear plastic. Pressure

More information

THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE

THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE www.winters.com MANUFACTURER OF INDUSTRIAL INSTRUMENTATION Bi-Metal Thermometers Bi-Metal Thermometers Winters bi-metal thermometers are direct sensing

More information

Pressure Gage and Swichgage Instruments OPL Series 4-1/2 in. (114mm) Diameter Dial

Pressure Gage and Swichgage Instruments OPL Series 4-1/2 in. (114mm) Diameter Dial sect. 05 9600 rev. 206/08/0 Pressure Gage and Swichgage Instruments OPL Series 4-/2 in. (4mm) Diameter Dial The OPL-series pressure Swichgage instruments are combination pressure indicating gages with

More information

2" & 3" Poly Wet Seal Pump Instruction Manual

2 & 3 Poly Wet Seal Pump Instruction Manual Always place the pump as close to the liquid to be pumped as possible. Keep the suction line short and with few bends. Keep the pump and engine on a level foundation. A poor foundation and a heavy suction

More information

VOYAGER 570G. 744A Sprayer Control

VOYAGER 570G. 744A Sprayer Control VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER

More information

Pressure Gauges. Industrial and Process. PGI Series. www.swagelok.com

Pressure Gauges. Industrial and Process. PGI Series. www.swagelok.com www.swagelok.com Pressure Gauges Industrial and Process PGI Series 4, 5, 63, 1, 115, and 16 mm (1 1/2, 2, 2 1/2, 4, 4 1/2 and 6 in.) dial sizes ccuracy in accordance with SME, EN, and JIS vailable with

More information

Volkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Volkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17) 17 Engine-Lubrication (Page GR-17) Lubrication system components, removing and installing Oil filter housing, disassembling and assembling Oil pan, removing and installing Oil pressure and oil pressure

More information

pdi PLASTIC DRUM INSTITUTE Plastic Drum Paneling Issues

pdi PLASTIC DRUM INSTITUTE Plastic Drum Paneling Issues pdi PLASTIC DRUM INSTITUTE Plastic Drum Paneling Issues PANELING BACKGROUND This report will explain the causes of paneling and suggest some possible ways to eliminate or minimize the paneling of plastic

More information

FRL/AirCare Air Controls & Accessories

FRL/AirCare Air Controls & Accessories FRL/irare ir ontrols & ccessories Lincoln Regulators, Filters & Lubricators well-planned compressed air system ensures minimum pressure loss in the system, and the removal of contaminants: water, compressor

More information

PVC Pipe PVC SCHEDULE 40. Nominal Pipe Size (in.) 1/8. Average I.D. O.D.

PVC Pipe PVC SCHEDULE 40. Nominal Pipe Size (in.) 1/8. Average I.D. O.D. CONDENSED CATALOG PVC HPB-0-A Effective 9//97 Revised //99 CLEAR / / / / -/ -/ -/ x/ CLEAR / / / / -/ PVC SDR. PSI (Water @ 7. F.) /.0.9.0.0 PVC SDR -/ -/ -/ 0 0 PVC SCHEDULE 0.0.7.0.00..7.7.00.000.00...

More information

Block and Bleed Gauge Valves M25 and M251

Block and Bleed Gauge Valves M25 and M251 Product Overview The M25 and M251 are two-valve single outlet gauge valves that combine isolating, calibrating, and venting facilities in a single compact unit. These valves enable gauges, pressure transmitters,

More information

Boiler Plan II Table of Contents

Boiler Plan II Table of Contents Cover Page Table Of Contents Introduction Parts List Additional Materials Assembly instructions Drawings 1-15 Boiler Plan II Table of Contents Introduction This will be a very rewarding project, if you

More information

ECM-D70T / ECM-D70T1.5

ECM-D70T / ECM-D70T1.5 Elliptical Ceiling Dual Mount for 37 to 50 Flat Panels INSTALLATION INSTRUCTIONS CREATING POSITIVE CUSTOMER EXPERIENCES 9531-041-001-01 Contents ECM-D70T / ECM-D70T1.5 Installation Tools... 3 Parts List...

More information

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below: Needle Valves : - Needle valves have a slender, tapered point at the end of the valve stem that is lowered through the seat to restrict or block flow. Fluid flowing through the Needle valve turns 90 degrees

More information

2:1 RATIO TRANSFER PUMP

2:1 RATIO TRANSFER PUMP OP232-INST 2:1 RATIO TRANSFER PUMP OPERATING MANUAL WITH PARTS IDENTIFICATION IPM INC. Manufactured by International Pump Manufacturing, Inc. Covers models: OP232C, OP242CD and OP242A. Manual Number: MOP232062008

More information

Tubular connection elements

Tubular connection elements KIRÁY TRING KFT H-1151 udapest Mogyoród útja 12 14tel: 061307-3801 Tubular connection elements 429 KIRÁY TRING KFT H-1151 udapest Mogyoród útja 12 14tel: 061307-3801 Technical information on the tubular

More information

Lenntech. 1000 psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503

Lenntech. 1000 psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503 1 User s Guide to: Phoenix Vessel Technology Limited 1000 psi End port pressure vessels 2.5. Model number: 1503 Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Phoenix

More information

Wafer Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Wafer Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1 Serial No. H-V066-E-2 Wafer Check Valve User s Manual Contents (1) Be sure to read the following description of our product warranty 1 (2) General operating instructions 2 (3) General instructions for

More information

FUEL SYSTEMS OUR PARTS PUT YOU IN THE PASSING LANE. Protect your fuel system. velvac.com

FUEL SYSTEMS OUR PARTS PUT YOU IN THE PASSING LANE. Protect your fuel system. velvac.com OUR PARTS PUT YOU IN THE PASSING LANE FUEL SYSTEMS Protect your fuel system. Velvac offers a wide range of locking fuel caps and anti-siphon tubes to keep unlawful occurances at bay. With OEM approved

More information

TECHNICAL SERVICE MANUAL

TECHNICAL SERVICE MANUAL TECHNICAL SERVICE MANUAL HEAVY-DUTY PUMPS SERIES 4195 AND 495 SIZES GG - AL SECTION TSM 144 PAGE 1 of 10 ISSUE D CONTENTS Introduction....................... 1 Safety Information.................... 2

More information

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version instrumentation for fluids Electromagnetic sensor Series FLOMID FX Instructions Manual! Conforms with the Pressure Equipment Directive 97/23/EC. 0830 This equipment is considered as being a pressure accessory

More information

CSD WATER REMOVAL FILTERS FOR DIESEL

CSD WATER REMOVAL FILTERS FOR DIESEL CSD CSD WATER REMOVAL FILTERS FOR DIESEL Remove water to extend fuel injector life & increase combustion fuel efficiency Remove free water to saturation point with high single pass efficienc (achieve

More information

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer Overview READ ENTIRE INSTRUCTIONS BEFORE STARTING INSTALLATION PARTS LIST A. Flush valve B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve

More information

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi Pipe Valves, Fittings and Nipples MAXIMATOR has been designing and manufacturing high pressure equipment for more than thirty years and has a worldwide reputation for quality and reliability, backed by

More information

RC 195 Multiple Input Receiver-Controller

RC 195 Multiple Input Receiver-Controller Document No. 129-230 RC 195 Multiple Input Receiver-Controller Product Description The RC 195 Multiple Input Receiver-Controller is a pneumatic instrument that can be used as a one input (DA or RA), two

More information

Replacing Displacers with Guided Wave Radar

Replacing Displacers with Guided Wave Radar ROSEMOUNT GUIDED WAVE RADAR Replacing Displacers with Guided Wave Radar KEY POINTS Mounting flanges vary by displacer supplier Probe must extend the of the displacer chamber Single rigid probes are the

More information

Owner s Manual & Safety Instructions

Owner s Manual & Safety Instructions Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s

More information

Introduction to vacuum gauges. Vacuum Gauges where the Pressure Readings are Independent of the Type of Gas (Mechanical Vacuum Gauges)

Introduction to vacuum gauges. Vacuum Gauges where the Pressure Readings are Independent of the Type of Gas (Mechanical Vacuum Gauges) Introduction to vacuum gauges Vacuum Gauges where the Pressure Readings are Independent of the Type of Gas (Mechanical Vacuum Gauges) BOURDON Vacuum Gauge The inside of a tube which is bent into a circular

More information

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts. www.tyco-fire.com

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts. www.tyco-fire.com Worldwide Contacts www.tyco-fire.com Model EC-HS 80 K-factor, Quick Response Extended Coverage Horizontal Sidewall Sprinklers Installations per VdS CEA 400, Annex E, LH/OH General Description The Model

More information

MODEL T200-F18 MODEL T125-F18 Finish Nailers

MODEL T200-F18 MODEL T125-F18 Finish Nailers P MODEL T200-F18 MODEL T125-F18 Finish Nailers IMPORTANT! DO NOT DESTROY It is the customer s responsibility to have all operators and service personnel read and understand this manual. OPERATING MANUAL

More information

IF IT FLOWS THE BOWIE PUMP CAN PUMP IT

IF IT FLOWS THE BOWIE PUMP CAN PUMP IT IF IT FLOWS THE BOWIE PUMP CAN PUMP IT Bowie Industries, Inc. Bowie, TX 76230 USA Page 1 Bowie Pumps Manual General Pump Information..Page 2 300 Series Pumps.. Page 5 400 Series Pumps.Page 11 500 Series

More information

product manual 08.09 H-4210A PORTABLE STATIC CONE PENETROMETER

product manual 08.09 H-4210A PORTABLE STATIC CONE PENETROMETER 08.09 product manual H-4210A PORTABLE STATIC CONE PENETROMETER PORTABLE STATIC CONE PENETROMETER GENERAL INFORMATION The H-4210A Static Cone Penetrometer is an unparalleled device for measuring soil consistency.

More information

High Pressure Equipment Pressure Vessels and Reactors Index

High Pressure Equipment Pressure Vessels and Reactors Index Pressure Vessels and Reacrs High Pressure Equipment Company designs and manufactures a broad range of pressure vessels and reacrs for both bench-scale and pilot plant applications. We have over 0 standard

More information

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage

More information

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing) CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.

More information

POWERS CONTROL RC 195 Single Input Receiver-Controller

POWERS CONTROL RC 195 Single Input Receiver-Controller Document No. 155-119P25 RC 195-4 POWERS CONTROL RC 195 Single Input Receiver-Controller Description The RC 195 Single lnput Receiver-Controller is a pneumatic instrument which receives one pneumatic input,

More information

DIAPHRAGM & DIFFERENTIAL PRESSURE GAUGES. Keeping pressure under control AN ISO 9000 COMPANY

DIAPHRAGM & DIFFERENTIAL PRESSURE GAUGES. Keeping pressure under control AN ISO 9000 COMPANY DIAPHRAGM & DIFFERENTIAL PRESSURE GAUGES Keeping pressure under control AN ISO 9000 COMPANY Diaphragm & Differential Pressure Gauges Diaphragm & Differential Pressure Gauges Contents Bailey & Mackey have

More information

Select Radiators Installation Guide

Select Radiators Installation Guide Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall

More information

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury. 1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is

More information

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves 2-way Integral Panel Mount Ball Valves Used for quick on-off service with a visual indication of flow, HOKE s 2-way ball valves offer orifice sizes up to 0.25 (6.4mm). Flomite valves feature a floating

More information

Instruction Manual Differential Pressure Transmitter

Instruction Manual Differential Pressure Transmitter DE28 Instruction Manual Differential Pressure Transmitter Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance

More information

This instruction is valid for all ACD pump models shown on page 2

This instruction is valid for all ACD pump models shown on page 2 Screw pumps ACD Maintenance and Service Instruction This instruction is valid for all ACD pump models shown on page 2 Contents Page List of components 2 Exploded view/ordering code 3 Service intervals

More information

KEEP FOR FUTURE REFERENCE MRTALP VERTICAL LIFT BAR READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT

KEEP FOR FUTURE REFERENCE MRTALP VERTICAL LIFT BAR READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT KEEP FOR FUTURE REFERENCE INSTRUCTIONS P.O. Box 368 908 West Main Laurel, MT USA 59044 phone 800-548-7341 phone 406-628-8231 fax 406-628-8354 International Version MODEL NUMBER: LB10VLB MRTALP VERTICAL

More information

Q&A Session for Advanced Ball Screws 102: Troubleshooting for Design Engineers

Q&A Session for Advanced Ball Screws 102: Troubleshooting for Design Engineers Q&A Session for Advanced Ball Screws 102: Troubleshooting for Design Engineers Topic: Noise Q: Is there a way to predict/calculate noise on a ball screw? A: No, there is no way to calculate the noise of

More information

Tube Type Oil Skimmer Comparison

Tube Type Oil Skimmer Comparison Process Overview- Tube Type Oil Skimmers Oil flows down the face of the skimmer and into a sludge pan that is plumbed to a barrel. Model BG01 & BG34 or 6V Oil Skimmer 1.0 or 3/4 Diameter Collector Tube

More information

Service Manual Rol-Lift

Service Manual Rol-Lift R 2000 Service Manual Rol-Lift Series: T and E Developed by Generic Parts Service This manual is intended for basic service and maintenance of the Rol-Lift pallet jack. The pallet jacks you are servicing

More information

INSTRUCTION MANUAL IM042. Slide Rail Systems - Series A10 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

INSTRUCTION MANUAL IM042. Slide Rail Systems - Series A10 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS INSTRUCTION MANUAL IM042 Slide Rail Systems - Series A10 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS TABLE OF CONTENTS SUBJECT PAGE Safety Instructions... 3 Descriptions and Specifications...

More information

Watts Pure Water Systems

Watts Pure Water Systems Watts Pure Water Systems WM-120-PT Installation and Operation Manual Premier Water Systems Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before

More information

APPENDIX 2-3 PCAPP EDS INSPECTION LOG SHEETS

APPENDIX 2-3 PCAPP EDS INSPECTION LOG SHEETS APPENDIX 2-3 PCAPP EDS INSPECTION LOG SHEETS Pueblo Chemical Depot Pueblo Chemical Depot (This page intentionally left blank.) PCAPP EDS Daily (When in Use) Operational Inspection Checklist EXAMPLE Inspected

More information

12 Volt 30 Amp Digital Solar Charge Controller

12 Volt 30 Amp Digital Solar Charge Controller 12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions

More information

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8

More information

OP300S / OP350 2:1 RATIO TRANSFER PUMP

OP300S / OP350 2:1 RATIO TRANSFER PUMP OP300S / OP350 2:1 RATIO TRANSFER PUMP OPERATING MANUAL WITH PARTS IDENTIFICATION Copyright 2013 International Pump Manufacturing, Inc. This manual contains IMPORTANT WARNINGS and INSTRUCTIONS. Read and

More information

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC) APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines

More information

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description The TYCO RAPID

More information

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS with the 263/742 Logix Control Valve June 2010 Table of Contents Page No.

More information

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E SENS part no: 101314 Document revision: F DCN No. 106811 Date 8/3/15 1840 Industrial Circle Longmont, CO 80501 Fax: (303) 678-7504

More information

Catalog 900. Product Catalog. Pressure and Temperature Measurement. Mechanical Pressure Diaphragm Seals Mechanical Temperature Accessories

Catalog 900. Product Catalog. Pressure and Temperature Measurement. Mechanical Pressure Diaphragm Seals Mechanical Temperature Accessories Catalog 900 Product Catalog Pressure and Temperature Measurement Mechanical Pressure Diaphragm Seals Mechanical Temperature Accessories R Product Catalog 900 Pressure and Temperature Measurement Product

More information

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description Product Manual CVS Type 67AFR Filter Regulator Introduction This CVS Controls product manual includes instructions for the installation, adjustment, maintenance and parts ordering of the CVS Type 67AFR

More information

Style 9168 Field Service Kit. 7980 Black Max Piston intake valve

Style 9168 Field Service Kit. 7980 Black Max Piston intake valve Style 9168 Field Service Kit for 7980 Black Max Piston intake valve 122610 STYLE 7980 BLACK MAX PISTON INTAKE VALVE 11-7/8 SEE DETAIL C 2 SEE DETAIL A 14 12 11 SEE DETAIL D 5 10 SEE DETAIL B SEE DETAIL

More information

Destiny Shower Enclosure Installation Instructions

Destiny Shower Enclosure Installation Instructions Destiny Shower Enclosure Installation Instructions IMPORTANT Please read carefully the following instructions before installing your shower enclosure. If you have any questions on this shower enclosure

More information

FOAM CHAMBER MODEL - FC

FOAM CHAMBER MODEL - FC FOAM CHAMBER MODEL - FC TECHNICAL DATA : MODEL SIZE WORKING PRESSURE FC 50, 65, 80, 100 &150 NB inlet Minimum 2.8 Kg. / sq. cm. (40 PSI) Maximum 7 Kg. / sq.cm. (100 PSI) FLANGE CONNECTION ANSI B16.5 Class

More information

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17) 17 Engine-Lubrication system (Page GR-17) Lubrication system components, removing and installing Oil pan, removing and installing Oil pressure and oil pressure switch, checking Dynamic oil pressure warning

More information

CDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

CDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive

More information

1000-LB. TRAILER JACK OWNER S MANUAL

1000-LB. TRAILER JACK OWNER S MANUAL 1000-LB. TRAILER JACK OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious

More information

O to 15,000 psi and media temperature between -130 F and 752 F. Examples of Typical Diaphragm Seal Applications

O to 15,000 psi and media temperature between -130 F and 752 F. Examples of Typical Diaphragm Seal Applications Diaphragm Seals > Diaphragm Seals Diaphragm Seals Diaphragm seals, also referred to as chemical seals, are used to isolate pressure gauges, switches and transmitters from clogging and/or corrosive media.

More information

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps Model Name Total Output Amps Per Bank Battery System Pro XL Dual Pro XL Pro SE Dual Pro SE Three Bank Pro SE Four Bank Pro SE Pro Charger Dual Pro Charger Three Bank Pro Charger 6 amps 12 amps 10 amps

More information

CITY OF BEAUFORT SOLICITING SEALED PROPOSALS FOR MOBILE REFUSE CARTS

CITY OF BEAUFORT SOLICITING SEALED PROPOSALS FOR MOBILE REFUSE CARTS CITY OF BEAUFORT SOLICITING SEALED PROPOSALS FOR MOBILE REFUSE CARTS The City of Beaufort is requesting sealed, competitive, proposals for interested Vendors to provide the City of Beaufort fifty-five

More information

The Original and Patented Stackable Poly Tanks. When You Want to Beat the Drum!

The Original and Patented Stackable Poly Tanks. When You Want to Beat the Drum! The Original and Patented Stackable Poly Tanks When You Want to Beat the Drum! A TOTE A LUBE STORAGE & DISPENSING SYSTEM IS A LOW COST INVESTMENT THAT PAYS HIGH DIVIDENDS IN TIME SAVED, EFFICIENT USE OF

More information

INSTALLATION MANUAL. Glass Vessel Sink. www.kraususa.com I toll free: 1.800.755.0703 I 2013-2014 Kraus USA Inc.

INSTALLATION MANUAL. Glass Vessel Sink. www.kraususa.com I toll free: 1.800.755.0703 I 2013-2014 Kraus USA Inc. INSTALLATION MANUAL Glass Vessel Sink www.kraususa.com I toll free: 1.800.755.0703 I 2013-2014 Kraus USA Inc. Thank You Kraus would like to take this opportunity to thank you for purchasing our products.

More information

BIMETAL THERMOMETERS Universal Mount All Star Adjustable Union All Pro Replaceable Element Slip-Fit 3A Sanitary Surface Thermometers Thermowells

BIMETAL THERMOMETERS Universal Mount All Star Adjustable Union All Pro Replaceable Element Slip-Fit 3A Sanitary Surface Thermometers Thermowells BIMETAL THERMOMETERS Universal Mount All Star Adjustable Union All Pro Replaceable Element Slip-Fit 3A Sanitary Surface Thermowells 316SS IP67 All Star now in 316SS with IP67 www.palmerwahl.com PW1120

More information

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89] Bulletin P-DM-1100 Series DM-1000 DigiMag Digital Differential Pressure Gage Specifications - Installation and Operating Instructions PRESSURE CONNECTIONS 21/64 [8.59] LONG Ø5 [127.00] 4-31/64 [113.89]

More information

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions. B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary

More information

UNITS Units are designated by the unmounted pump model numbers followed by a letter indicating drive style.

UNITS Units are designated by the unmounted pump model numbers followed by a letter indicating drive style. TECHNICAL SERVICE MANUAL UNIVERSAL SEAL HEAVY DUTY PUMPS SERIES 124A, 4124A, 224A, 224AH, 4224A AND 4224Ah CAST IRON SERIES 126A, 4126A, 226A AND 4226A DUCTILE IRON SERIES 123A, 4123A, 223A AND 4223A STEEL

More information

FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases

FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases READ THIS MANUAL COMPLETELY BEFORE ATTEMPTING TO CONNECT OR OPERATE YOUR FLOW SENSOR. FAILURE TO DO SO MAY RESULT IN INJURY TO YOU OR DAMAGE TO

More information

Explosion-Proof Electric Unit Heaters

Explosion-Proof Electric Unit Heaters Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,

More information

OWNER S MANUAL Table Tennis Table Patent Pending

OWNER S MANUAL Table Tennis Table Patent Pending OWNER S MANUAL Table Tennis Table Patent Pending Be sure to write your model number and serial number here for future reference. You can find these numbers printed on the bottom of the table. MODEL # T8179

More information

3M Housings DS Series

3M Housings DS Series Lenntech info@lenntech.com Tel. +1-15-610-900 www.lenntech.com Fax. +1-15-616-89 M Housings For Filters Filter Housings, constructed of durable stainless steel, meet general-purpose industrial, chemical,

More information

WH/WIH/WIHD/WIHD&M/WIHL AND WIH 17-67 SERIES

WH/WIH/WIHD/WIHD&M/WIHL AND WIH 17-67 SERIES WH/WIH/WIHD/WIHD&M/WIHL AND WIH 17-67 SERIES Service and Installation Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect

More information

Mini-led spotlight with magnetic base

Mini-led spotlight with magnetic base Mini-led spotlight with magnetic base Model 95799 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission

More information

http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html

http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html TECHNICAL SERVICE DEPARTMENT Removal, Cleaning, & Reinstallation of the Burner Assembly For models 74 & GT199 Required tools -

More information