1 GSM Remote control Version W-BUS v9.x Operating manual
2 Antenna Status LED Release SMA Connection SIM card Front view Release PIN 1 PIN 8 Back view
3 Table of contents 1 Scope of delivery Safety instructions Intended use Obligation and liability Malfunction Disposal Declaration of conformity Device description Function Alarm function Switching acknowledgement Status LED SIM card Inserting the SIM card Inputs and outputs electrical connection General Connection of ext. button Heater blower control Start up Configuration parameter Configuration with SMS configurator Configuration with mobile phone Delete a phone number SMS commands Trouble shooting Manufacturer technical data Copyright... 26
4 1 Scope of delivery GSM remote control GSM antenna (straight) 8-pole connection line (14-pole connector) Operating manual optional available accessories vehicle-specific cable harnesses Y-connection lines for Webasto and Eberspächer Indoor window antenna Antenna adapter (FME to SMA) Prior to insertion of the SIM card please deactivate the PIN request and the mailbox and delete all telephone numbers that may be stored. The operation of the GSM remote control will require any SIM card which is not included in the scope of delivery. 4-28
5 2 Safety instructions Prior to the commissioning of the device please read this operating manual completely. Additionally you have to observe the generally valid and the local regulations for accident prevention and environmental protection. Keep the operating manual. Do not operate the device in a surrounding where flammable gases, vapours, liquids or dusts are existing or may exist. Do not use the GSM remote control if due to a malfunction danger and / or damage may occur. 3 Intended use The GSM remote control allows the switching of any device per APP, SMS or call. The GSM remote control is designated for private use and not for commercial purposes. The GSM remote control has to be used exclusively according the instructions of this operating manual. The manufacturer is not liable for damages which are caused by inappropriate use or incorrect operation. The installation must only be carried out by a qualified technican. 5-28
6 4 Obligation and liability The GSM remote control has been developed and manufactured according to the current technical status and the recognized safety rules. It cannot be assured, however, that the GSM remote control will operate as intended under all circumstances, at any time and under all conditions. Do not use the GSM remote control for the switching of life-support systems or devices with an emanating danger due to an uncontrolled switching on and off. The DANHAG GSM remote control is manufactured in compliance with the EU directive 2011/65/EG (RoHS 2). This directive determines the use of hazardous material in devices and components. The compliance with the prescribed EMC limit values was confirmed by an independent EMC testing laboratory. Our products are recorded in the register for waste electrical equipment and meet the requirements of the relevant, applicable CE regulations. We confirm the observation of European standards on our devices by the CE marking. WEEE Reg. No.: DE We only use sales packaging licensed by the disposal company "Zentek duales System". 6-28
7 5 Malfunction The GSM remote control must be taken out of service immediately when it might be assumed that a safe operation cannot be guaranteed any more. All appropriate measures must be taken to exclude an unintentional recommissioning. Only a qualified person is allowed to perform a repair. 6 Disposal This product must be taken to an official collecting point for disposal. You can also give back the product to the manufacturer for ecological disposal. This product must be kept out from the domestic waste. Please dispose the product according to the applicable legal provisions only. 7 Declaration of conformity The device is complying with the EU regulation 2004/108/EG (electromagnetic compatibility). Applied standards: EN /
8 8 Device description 8.1 Function The GSM remote control is equipped with 3 switching outputs. Only the previously configured, authorized call numbers can release the switching operation. Switching output 1 (yellow) : +12V / W-BUS Switching output 2 (black) : +12V Switching output 3 (purple) : Ground (not potential-free) The GSM remote control may be used only for the switching of max. 12V, 1A. For the switching of higher voltages / currents you have to use an additional relay. 8.2 Alarm function The GSM remote control is equipped with an alarm input which can be connected to an existing alarm system. After connecting the power supply to the GSM remote control, the voltage level on the alarm input will be stored (0 or +12V). As soon as this level changes, the alarm will be triggered and all stored numbers are informed by call and SMS. 8-28
9 8.3 Switching acknowledgement Switching by call When switching the GSM remote control by call, you will hear a dial tone. During this time the caller s phone number will be interpreted. In case of a valid phone number the switching operation will be released and you will hear a busy tone Switching by APP or SMS You can query the current switching status of the GSM remote control by sending a SMS with the text "INFO" to the GSM remote control. As from version v9.3 you will obtain a SMS, either if the heater was started successfully or when a fault has occurred. 8.4 Status LED The Status LED shows the current status of the device. Status LED flashing green (every 3s) fighting green flashing red fighting red Standby (logged in) Switching output active Network search (not logged in) fault 9-28
10 9 SIM card Any SIM card is required for the operation of the GSM remote control (Prepaid or subscription). 9.1 Inserting the SIM card Disconnect the power supply from the device remove the SIM card holder (Please press the release button slightly to release the holder) insert the SIM card into the holder push the SIM card holder into the device connect the power supply 10-28
11 10 Inputs and outputs PIN Color Description Function 1 yellow Switching output 1 Output +12V, W-BUS, E-BUS 2 black Switching output 2 Output +12V, max. 1A 3 purple Switching output 3 Output ground, max 100mA (not potential-free) 4 Output GND output GND 1KOhm für ext. LED 5 green Input +12V Input for ext. button / switch Button: one impulse (approx. 1s) is turning the Switching outputs alternately on and off ("on" for preset time) Switch: as long as +12V are applied the Switching outputs are activated (max. for preset time) 6 Output +12V Output +12V for ext. Button 7 red Supply voltage +12V (fuse with 5A) 8 brown Ground Ground connection
12 PIN Color Description Function blue Input Alarm +12V / GND Input for an existing alarm system (see alarm function) 14 orange Input Ignition Input ignition (terminal 15). Switching the ignition on deactivates all switching outputs. The inputs and outputs marked with " " must be connected for the basic functionality of the device. All further connections can be used optionally
13 11 electrical connection 11.1 General If there is a parking heater already installed, you can connect the GSM remote control directly to the timer or the receiver of the radio remote control. An Y- cable for easy "Plug & Play" connection is available for most operating elements Connection to existing operating element If your parking heater is controlled via a standard operating element (timer, radio remote control) you can connect the GSM remote control with a Y-cable. This Y-cable will be connected instead of the original cable and is equipped with an additional connection for the GSM remote control ensuring the power supply. The Y-cable is available optionally Connection to parking / auxiliary heater The GSM remote control allows the switching of parking heaters which are controlled by +12V, ground, W-bus or E-bus. For this, you have to connect the respective switching output (yellow, +12V/W-bus/E-bus or purple, ground) to the control input of the heater. On our homepage you can find an overview of the output signal required by your vehicle or heater. If you have any question please don t hesitate to contact our customer service
14 11.2 Connection of ext. button The button / switch is connecting PIN6 (+12V) with PIN5 of the 14-pole connecting plug. There is a ground signal on PIN4 present as long as the switching output is active. PIN4 has a resistor integrated to drive a LED directly. white (red) green (green) brown (brown) DANHAG button 14-pole socket of GSM remote control Wire-colors are coresponding to the original DANHAG button. Colors in brakets are coresponding to the WEBASTO button Difference between button and switch Button: Pressing the button shortly (approx. 1s) will switch on the heater for the preset time. If you want to switch of the heater you have to press the button once again. Switch: The heater is running as long as the switch is closed, however, not longer than the preset time
15 11.3 Heater blower control The heater blower is only working if the ignition is switched on. If there is a parking heater already installed, the blower will be controlled during the parking heater operation by the heater. Otherwise you have to install a IPCU module or a relay. If you have connected the GSM remote control with an Y- cable to an existing operating device (e.g. timer 1533 or radio remote control T91) the heater blower is controlled by the heater using a relay In vehicles with manual climate control, the blower speed can be set by a multistage switch. In this case you have to install an additional relay. Output 2 (black) + 12V permanent (KL30) relay ground to multi-stage-switch 15-28
16 using an IPCU-Modul Vehicles with an automatic climate control are using an electronic PWM signal (IPCU) to control the heater blower speed. The blower speed can be set by using the climate controls (digital display). In this case you have to connect an additional IPCU module. The IPCU module is available separately and not included in the scope of delivery. Function: If switched-off, the IPCU module will be looping trough the original PMW signal to the heater blower motor and the blower speed can be set on the climate control unit as usual. If the heater has been switched on with the GSM remote control, the heater blower will be controlled directly by the IPCU module
17 12 Start up Prior to start-up please read the complete instruction manual. Insert the SIM card into the GSM remote control connect the GSM remote control to the 14-pole connector wait until the GSM remote control is logged-in (LED flashing green) configure the GSM remote control After connecting the power supply, the GSM remote control will perform a selftest. The LED will be lighting red for approx. 4 seconds and then begins to flash red (network research). As soon as the GSM remote control is logged in into the GSM network, the LED will be flashing green. Now, the remote control is ready to operate and can be configured. Please deactivate the PIN query prior to the insertion of the SIM card. Otherwise the GSM remote control cannot log in into GSM network. Therefore please insert the SIM card if required - in a "normal" mobile phone and use the function "Deactivate PIN query"
18 13 Configuration After the first start you have to configure the GSM remote control per SMS once. The settings are stored, even in case of disconnecting the power supply. The following functions and settings can be configured: Password for the SMS configuration you will need the 5-digit password the password can be modified and must consist of 5 figures (preset "12345") after a reset the password will be set back to Running time Determines how long the switch outputs will be activated. from 1s - 59s from 1min 999min permanent Switch-on delay Determines if switching output 2 (black) will be activated at once or delayed. Switch-off delay Determines how long switching outputs 2 (black) and 3 (purple) will remain active after the heater has been switched off
19 Output signal Determines which output signal is used at switching output 1 (yellow). You will find an overview of the output signal required by your heater or vehicle at: Alarm delay Determines how long the alarm signal must be present continuously before the alarm is triggered. Phone numbers / Master number you can specify 5 authorized phone numbers Phone number 1 is the master number to which all info SMS will always be sent The GSM remote control will perform the switching operation only if it is switched by one of the authorized phone numbers per APP, SMS or call Please enter the phone number with the international prefix (e.g. +49 for germany). The phone number must not exceed 17 digits in total
20 Special function Determines if switching output 3 (purple) will be switched together with switching output 2 (black) (standard) or if switching output 3 can be switched separately by SMS using "ON2" or "OFF2". Status report (from SW Version v9.3) Determines if and which status reports will be sent by the GSM remote control. 0: all status reports deactivated 1: only fault messages 2: only switch-on messages 4: only switch-off messages If you want to be informed about several events, you have to add up the corresponding numbers. E.g. for fault and switch-off messages you have to enter 5. (1 + 4 = 5) Status reports will be supported from SW Version v9.3 and only for W-Bus controlled heater
21 13.1 parameter Nr. Function Setting Remark 00 Password 5 digits Preset "12345" Master number Phone number 2 max. 17 digits Enter phone numbers with international prefix 13 Phone number 3 14 Phone number 4 15 Phone number 5 20 Running time (minutes) Germany Austria e.g min 1000: permanently on 21 Switch-on delay min for output 2 22 Switch-off delay min for output 2 and 3 23 Running time (seconds) 0-59 s Running time in seconds 30 Output signal +12V, W-BUS for output 1 32 Special function (Output 3) 0 1 Standard Switching with "ON2", "OFF2" 33 Status reports 0-7 0: deactivated 40 Alarm delay sec 251: Alarm deactivated 21-28
22 13.2 Configuration with SMS configurator Please use the SMS configurator on for the configuration. Alternatively you can also generate and send the SMS with your mobile phone. After successful configuration the GSM remote control will send an SMS with an overview of the current settings to the master number Configuration with mobile phone Each function and / or setting has an assigned number. The assignment of the respective parameter is carried out by a = sign. Close up each input with a ;. You can summarize several functions in one SMS (max. 150 digits). Finish the configurations SMS with #. Example SMS The example SMS configures the GSM remote control as follows: Master number: Phone number 2: Running time: 30 minutes and 5 seconds Switch-on delay: 5 minutes Switch-off delayit: 1 minutes Output signal: W-BUS Syntax: 12345;11= ;12= ;20=30;23=5;21=5;22=1;30=3;# 13.4 Delete a phone number You can delete a phone number by overwriting it with "0"
23 13.5 SMS commands You can control the GSM remote control by APP, SMS or call. The following table shows the supported SMS commands. Command INFO TEMP ON OFF START0630 STOP GPS Function Query of current settings Query of module temperature switches the heater on switches the heater off Timer function e.g.: heater starts at 6:30 am switches the heater off and deletes the timer Query of current GPS position (optional) If you use an APP for controlling the heating, it also sends the corresponding SMS commands in the background. Depending on your mobile phone contract, additional costs may occur due to the SMS sending. Switching the heater by calling is free of charge
24 INFO SMS You can query the current settings of the GSM remote control by sending an SMS with the Text "INFO" to the GSM remote control. Then you will receive an SMS with a summary of the settings to the master number. DANHAG GSM Status: off 20) 20min,0s 21) 0min 22) 0min 30) +12V 40) 3s Status Status of heater (on, off) Timer Preset running time Signal Field strength (0-31) (10: bad, 31: very good) PWD Current pass word SW Software version Timer: off Signal: 21 PWD: SW: v
25 14 Trouble shooting Fault description Fault Cause of fault LED flashing rapidly red LED lighting up shortly, red, every 60s No switching operation at call GSM module not logged in Under-voltage on module Not / incorrectly configured PIN query not deactivated SIM not correctly inserted no reception Check supply voltage and the fuse (5A) Phone number existing twice on SIM card GSM remote control not configured yet no INFO-SMS query possible no credit on SIM card of GSM remote control delete all phone numbers / SMS on SIM card and re-configure load credit Heater is not running during preset time Under-voltage on heater or maximum heating time achieved Check vehicle battery GSM remote control cannot be configured wrong pass word (PWD) after reset the PWD will be set to "12345" 25-28
26 15 Manufacturer Ing. Büro Gornicki Boizenburger Str. 30 D Berlin info@danhag.de Webseite: 16 technical data Supply voltage: VDC Current consumption: Standby ca. 10mA, kurzzeitig max. 2A Switching output 1: W-BUS or +12V, max. 1A Switching output 2: +12V, max 1A Switching output 3: Ground, max. 300mA Operating temperature: -30 C to 80 C Dimensions: 64 x 60 x 22mm (L x B x H) plus antenna 17 Copyright All brands and trademarks mentioned in this operation manual and possibly protected by third parties are unlimitedly subject to the regulations of the respectively valid trademark law of the respectively registered owners. The bare mentioning does not allow the conclusion that brands are not protected by rights of third persons. The brands and trademarks mentioned in this operation manual are property of the respective copyright holder and are only used descriptively. Reproduction, copying and publication are allowed with written approval only. (c) Ing. Büro Gornicki 26-28
27
28
GSM remote controller v7.0 / v7.0 PRO. Operating Instructions
GSM remote controller v7.0 / v7.0 PRO Operating Instructions Table of contents 1 Delivery content...3 1.1 optional accessories...3 2 Safety...4 3 Intended use...4 4 responsibility and liability...5 5 Malfunctions...5
More informationInstallation Instructions. Thermo Call TC3
Installation Instructions Thermo Call TC3 1 2 # 24990A 965 082 AMP 3 4 # 98393A # 67769A sw Improper installation or repair of Webasto heating and cooling systems can cause fire or the leakage of deadly
More informationGSM Smart Switch USER GUIDE
GSM Smart Switch USER GUIDE GSM Smart Switch allows switching almost any appliance ON and OFF remotely via mobile network. It is designed to receive start/stop commands from specially coded messages or
More informationGSM HOME SECURITY SYSTEM
Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : GSM-120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5.
More informationOperating Instructions Thermo Call TC3. General Information. Use. Dear Webasto customer,
Operating Instructions Thermo Call TC3 General Information Dear Webasto customer, Thank you for purchasing the new Thermo Call TC3. This product provides you with a convenient, innovative way to operate
More informationInstallation Instructions. ThermoCall TC4. Entry/Advanced
Installation Instructions ThermoCall TC4 Entry/Advanced Thermo Call TC4 1 2 # 24990A 965 082 AMP 3 4 # 98393A # 67769A Thermo Call TC4 5 ThermoCall TC4 Entry 1 2 3 4 5 6 7 8 9 10 11 12 sw Please refer
More informationPUSH BUTTON START INSTALLATION MANUAL
PUSH BUTTON START INSTALLATION MANUAL ALTHOUGH THIS PRODUCT HAS BEEN THOROUGHLY TESTED KPIERSON TECHNOLOGIES ASSUMES NO RESPONSIBILITY FOR ANY DAMAGE THAT MAY RESULT BY THE INSTALLATION OF THIS PRODUCT.
More informationGSM-DIN3. GSM Communicator. Instructions: January 5, 2013, refers to the firmware version: 1.014
GSM-DIN3 GSM Communicator Instructions: January 5, 2013, refers to the firmware version: 1.014 FLAJZAR company expanded its range of GSM, communicators on an 230V DIN version - that is designed to be mounted
More informationOperating Instructions. ThermoCall TC4. Entry / Advanced
Operating Instructions ThermoCall TC4 Entry / Advanced Table of Contents 1 About This Document......................................... 1 2 General Information..........................................
More informationCopyrights 2010 Victron Energy B.V. All Rights Reserved
Manual EN 1 Copyrights 2010 Victron Energy B.V. All Rights Reserved This publication or parts thereof may not be reproduced in any form, by any method, for any purpose. For conditions of use and permission
More informationStructureScan HD Module. Installation Guide ENGLISH. www.bandg.com www.simrad-yachting.com www.lowrance.com
StructureScan HD Module Installation Guide ENGLISH www.bandg.com www.simrad-yachting.com www.lowrance.com Disclaimer As Navico is continuously improving this product, we retain the right to make changes
More informationCelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual
CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CGWTS-M001A Version 1, Release 1, December 2004 NOTICE
More informationManual. Simrad StructureScan LSS-1 Sonar Module. English
Manual Simrad StructureScan LSS-1 Sonar Module English www.simrad-yachting.com A brand by Navico - Leader in Marine Electronics Disclaimer As Navico is continuously improving this product, we retain the
More informationEricsson W25. Mobile Networks. Quick Installation Guide
Ericsson W25 Fixed Wireless Terminal for WCDMA/HSDPA Mobile Networks Quick Installation Guide Table of Contents INTRODUCTION... 3 Package Contents... 3 Requirements... 3 INSTALLATION... 4 Unit Preparation...
More informationOriginal instructions Tina 3A/Aps Adaptor unit
Original instructions Tina 3A/Aps Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
More informationThe GD-04K universal GSM communicator and controller
The GD-04K universal GSM communicator and controller The GD-04K is a universal GSM communicator. It controls and / or reports status of different appliances remotely. Control can be performed by SMS instructions
More informatione-ask electronic Access Security Keyless-entry
e-ask electronic Access Security Keyless-entry e-fob Keyless-entry entry System Full-Function Function Installation Manual FCC ID: TV2EFOB1 (UM20 ~ 22793-02) Table of Contents Introduction... 1 e-fob Operation
More informationUSER MANUAL V5.0 ST100
GPS Vehicle Tracker USER MANUAL V5.0 ST100 Updated on 15 September 2009-1 - Contents 1 Product Overview 3 2 For Your Safety 3 3 ST100 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2
More informationModular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
More informationUSER MANUAL. Model 6103 3U ForeFront Alarm Card SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007. An ISO-9001 Certified Company
USER MANUAL Model 6103 3U ForeFront Alarm Card An ISO-9001 Certified Company Part# 07M6103 Doc# 123011U Rev. A Revised 7/15/03 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 CONTENTS 1.0
More informationwww.sebury.com.cn Digital Keypad Use s Manual
K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4
More informationInstallation guide H-5500-8554-03-A. HSI hardwired system interface
Installation guide H-5500-8554-03-A HSI hardwired system interface 2008-2011 Renishaw plc. All rights reserved. This document may not be copied or reproduced in whole or in part, or transferred to any
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationBusiness/Home GSM Alarm System. Installation and User Manual
Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene
More informationAlarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6
Alarm over IP IRIS Touch Home Installation Manual Version 1.0 ENGLISH Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6 1. Introduction No more bulky batteries, just one sleek unit
More informationKD-204. Telephone Remote Switch. Operating Instructions
KD-204 Telephone Remote Switch Operating Instructions 1. GENERAL DESCRIPTION The telephone remote switch consists of three parts, which are the telephone modem that can be connected to the landline telephone
More informationGETTING TO KNOW YOUR TELSTRA PRE-PAID 3G WI-FI
GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G WI-FI LET S GET THIS SHOW ON THE ROAD You must be excited about your brand new Telstra Pre-Paid 3G Wi-Fi. This guide will help you get connected as quickly and
More informationIntelligent GSM Auto-dial Alarm System User s Manual
Intelligent GSM Auto-dial Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. [Function Instruction] [Control Panel Introduction]
More informationDR 70 Portable Digital DAB+ and FM Radio Receiver User Manual English Please read carefully before using this product
DR 70 Portable Digital DAB+ and FM Radio Receiver User Manual Please read carefully before using this product 15 1 Table of Contents 1 Table of Contents... 16 2 Safety Instructions:... 17 3 Specification:...
More informationMy home. Mobile phone application. Instructions for use and installation. For DELTA DORE GSM transmitters and transmitter control units.
My home Mobile phone application For DELTA DORE GSM transmitters and transmitter control units Instructions for use and installation My home Alarm Heating Bedroom Dining room Kitchen Garage Absence Messages
More informationE&P HYDRAULICS Remote control EPRC-01 Level System Camper
USER S GUIDE E&P HYDRAULICS Remote control EPRC-01 Level System Camper 1 Copyright 2012, E&P Hydraulics This manual is copyrighted, with all rights reserved. Under the copyright laws, this may not, in
More informationMANUAL GSM CONTROLLER
MANUAL GSM CONTROLLER CallFree2 CallFree 3G 2 outputs, 3 inputs ` Please read these instructions completely before use GSM CallFree 1/17 Revision V1.3C, Aug 2015 TABLE OF CONTENTS 1. SAFETY PRECAUTIONS...
More informationRousseau 10. User Guide
Rousseau 10 User Guide Base station overview ➀ LED signals White, permanent light: - Base station ready, you can register a handset Slow flashing white light: - Paging call in progress - Active call (you
More informationTina 2A/B Adaptor unit
Original instructions Tina 2A/B Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
More informationGSM-AUTO+ GSM Controller with Internal Power Supply User manual
GSM-AUTO+ GSM Controller with Internal Power Supply User manual INDEX Description... 2 Preparing the SIM card... 3 Installation... 4 Example connections... 5 Programming commands... 6 Quick reference of
More informationGSM Alarm System User Manual
GSM Alarm System User Manual For a better understanding of this product, please read this user manual thoroughly before using it. Quick Guider After getting this alarm system, you need to do the following
More informationuser manual smappee monitor
user manual smappee monitor January 2014 (English), version 2.02 2013 smappee NV. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective
More informationGSM Desktop phone DPH101. User manual v1.00
GSM Desktop phone DPH101 User manual v1.00 LEGAL NOTICE Copyright 2011 TELTONIKA Ltd. All rights reserved. Reproduction, transfer, distribution or storage of part or all of the contents in this document
More informationPortal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO
GSM-PRO GSM-PRO perfect for communication CONTA-CLIP s GSM-PRO module offers a remote control and maintenance solution which allows you to monitor and control decentralized facilities. The GSM-PRO module
More informationFanControl U2 Connection of the module in BMW and Mini Cooper vehicles
FanControl U2 Connection of the module in BMW and Mini Cooper vehicles www.tecel.ru Module application in BMW 5 (F10), BMW 6 (F13), BMW 7 (F01, F02) vehicles Group 4, subgroup 2 CАN L green CAN H orange
More informationGSM WIRELESS DIGITAL ALARM SYSTEM USER GUIDE. Please read it carefully before installation and operation
GSM WIRELESS DIGITAL ALARM SYSTEM USER GUIDE Please read it carefully before installation and operation Your New Diamond Designs Alarm works with a GSM SimCard via the cellular phone,system to call up
More informationInwall 4 Input / 4 Output Module
Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...
More informationHCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply
1. INTRODUCTION HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply User Manual This family of efficient, upgraded SMPS with small form factor, auto cross over CV CC,
More informationAN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T
Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting
More informationINSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK
Security Door Controls 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP
More informationUSER MANUAL OPERATION AND USE OF CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM
USER MANUAL OPERATION AND USE OF CAR WITH Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM Page 2 z 7 Table of contents 1. STARTING THE ENGINE... 3 2. CONTROL PANEL... 3 2.1 Indication of the current level
More informationEasyStart R + Operating instructions. Comfort radio remote control with integrated timer for parking heaters and more.
EasyStart R + Operating instructions. Comfort radio remote control with integrated timer for parking heaters and more. 22 1000 32 80 06 03.2009 Contents Introduction Please read first... 3 Purpose... 3
More informationRoadstar Installation Instruction Manual
Roadstar Installation Instruction Manual This instruction manual describes installation of GPS/GPRS vehicle tracking device Roadstar. Modem is already set to work with system for vehicle tracking, and
More informationGSM Autodialer Professional GJD700 Speech & Text Autodialer
Text Edit message GSM Autodialer Professional GJD700 Speech & Text Autodialer Introduction The GSM Autodialer Professional works in conjunction with standard alarm systems and makes use of your preferred
More informationElectronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
More informationCCTR-805-V2 3G Car GPS Tracker-201604
CCTR-805-V2 3G Car GPS Tracker-201604 Welcome to use this real time car GPS tracker CCTR-805G.This product is with GPS module and 2G GSM / 3G WCDMA module (with LBS locate without GPS), that has many new
More informationGSM ATT Modules Simply effective remote control
GSM ATT Modules Simply effective remote control To control electrical loads via mobile phone The benefits Remote management of electrical devices is an increasingly widespread requirement in residential
More informationSECURITY SYSTEM ADP-CAN
INSTALLATION INSTRUCTION SECURITY SYSTEM ADP-CAN Introduction Motorcar security system ADP-CAN is for motorcars provided with CAN net. It is for the work with the motorcar factory security systems or remote
More informationInstallation Fleet Tracker (SBC3)
Installation Fleet Tracker (SBC3) VERSION DATUM AUTOR DATEINAME 1.1 21. MAI 2012 SM EINBAU FLOTTENSBC3_ENGLISCH_V11.DOCX The installation should be done by qualified personnel, who is experienced in dealing
More informationCar Alarm Tracker Manual-20150814
CCTR-922 Car Alarm Tracker Manual-20150814 Welcome to use this GSM car alarm with tracker function CCTR-922. this product use 2G GSM network (LBS locate) to locate the car, it has many new and unique functions,
More informationUser Manual. Genius GPS / GSM 810 Real Time GPS Tracker. Android App Download. Iphone App Download ENGLISH. Genius Advanced Technologies
Genius GPS / GSM 810 Real Time GPS Tracker User Manual Android App Download Iphone App Download www.geniuscaralarm.com 1 Genius GPS / GSM 810 Real Time GPS Tracker Welcome to use this real time car GPS
More informationUser Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual
ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) User Manual Table of Contents 1 Introduction 2 General specification 3 Installation 4 Pin assignment & function of connectors 5 Drawing
More informationButton 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition
WWW.STELLAR.COM ST9000 SECURITY SYSTEM Button Function Condition 1 a. Arm and lock doors b. Car finder with sound c. Temporary stop alarm from sounding d. Remote lock doors 1 for 2 sec. Panic Anytime a.
More informationLG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
More informationGetting started with
PART NO. CMA113 MADE IN CHINA 1. Measuring CAT II 2. Max. voltage 250V ~ 3. Max. current 71 Amp Getting started with Electricity consumption monitoring single phase for homes and some smaller light commercial
More informationalpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG
alpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG Safety precautions Safety precautions The DSL modem alpha DSL WTM EG complies with the European norm EN60950 safety of information technology
More informationThermo Top - Troubleshooting Tree
Thermo Top - Troubleshooting Tree 07-15-2002 CAUTION Troubleshooting requires comprehensive knowledge about the structure and theory of operation of the Thermo Top heater. Troubleshooting and repairs may
More informationACS-30-EU-EMDR-10-MOD
Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature
More informationCMD-8000 rev. A COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM
INTRODUCTION CMD-8000 rev. A COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM Thank you for purchasing the CMD-8000 Commander from Dakota Digital. This, along with many other products that Dakota Digital has
More informationGSM-DL2 GSM auto dialer
Introduction GSM-DL2 GSM auto dialer GSM-DL2 is a GSM auto dialer; designed for car alarm, boat alarm, home alarm and other applications. When it is triggered, it dials pre-programmed telephone numbers
More informationStove Guard Kit User Manual
Stove Guard Kit User Manual Innohome improves the Safety of your Home. inno home www.innohome.com Stove Guard Kit User Manual Stove Guard Kit User Manual Congratulations! You now own one of the most intelligent
More informationTO-PASS. TO-PASS -FAQ- Remote Monitoring. What is TO-PASS used for? What are the special functions of TO-PASS?
TO-PASS -FAQ- Remote Monitoring What is TO-PASS used for? TO-PASS modules are used as/for: Permanent online connection Fault detectors Remote data polling Data storage Telecontrol module What are the special
More informationGSM Controller User manual
GSM-AUTO GSM Controller User manual INDEX Description... 2 Preparing the SIM card... 3 Installation... 4 Example connections... 5 Programming commands... 7 Quick reference of programming commands....12
More informationCCTR-800 Portable Real Time GPS Tracker
CCTR-800 Portable Real Time GPS Tracker Welcome to use this Real Time GPS tracker CCTR-800, This product is with GPS module and GSM module, It has many new and unique functions, such as real time uploading
More information500r+ Installation and User Guide
500r+ Installation and User Guide Compatible Equipment 502rUK-50 Watch/Pendant PA. 509rUK-50 Smoke Detector 515rUK-00 10 metre passive infra red movement detector. 525rUK-00 Remote Set/Unset (Full and
More informationDaker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
More informationOperating Instructions
Operating Instructions Kühn Controls AG, Gräfenhäuser Str. 14, D-75305 Neuenbürg, Germany Tel. +49 (0)7082-94 00 00 www.kuehn-controls.de sales@kuehn-controls.de Fax +49 (0)7082-94 00 01 Content 1. SMS
More informationCombi B Alarm box. Mounting instructions
Combi B Alarm box Mounting instructions EN Mounting instructions Alarm box Combi B VdS, G113064, G113065, G113066 Table of Contents 1 Description... 3 2 System overview... 3 3 Structure... 3 3.1 Power
More informationManual for Fire Suppression & Methane Detection System
Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327
More informationINSTALLATION MANUAL XM3 Reader
INSTALLATION MANUAL XM3 Reader Conditions Transactions, deliveries et cetera will be according to the general terms of delivery as deposited at the Chamber of Commerce at Meppel, The Netherlands. Registration
More informationQuick Installation Guide LCD GSM ALARM SYSTEM LH http://www.usmartbuy.com
A. Manipulation Specification Quick Installation Guide 1. Arming Arming means all-around guarded when there is no person at home. All detectors are working. Once something triggers any of the detectors,
More informationFalcon Protector Tracking System
Falcon Protector Tracking System Product Overview The Falcon Protector is a GPS and GSM tracking device which is specially developed and designed for vehicle tracking. With the latest SIFR III GPS module
More informationFleets Vehicle GPS Tracker TS20 User Manual. (Version 1.0)
Fleets Vehicle GPS Tracker TS20 User Manual (Version 1.0) Index Contents 1. Package Contents... 3 2. Features and Specifications... 3 3. Mechanical Size... 4 4. Knowledge before Usage... 4 4.1 Factory
More informationInstruction Manual for Operating Panel 301 and 302
Instruction Manual for Operating Panel 301 and 30 Edition: 1/006 Edition: 1/006 Contents 1 Introduction and Overview........................ 5 1.1 Panel 301 Controls........................................
More informationIPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network
IPThermo206G Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network IPThermo 206G is the central data handling terminal of the IPThermo Pro measurement network. This
More informationANTI-THEFT SYSTEM. 1995 Volvo 850 DESCRIPTION & OPERATION BASIC ALARM. 1995-96 ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems
ANTI-THEFT SYSTEM 1995 Volvo 850 1995-96 ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems 850 DESCRIPTION & OPERATION WARNING: Deactivate air bag system before performing any service operation. For 1995
More informationHow To Control A Car Alarm On A Car With A Remote Control System
MODEL CA100 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM Black Antenna Wire 6 Pin 6 Pin Mini Connector Valet Switch Blue LED Indicator Blue Wire: (-) 200mA Unlock
More informationUser guide. T250i. This is the Internet version of the User's guide. Print only for private use.
User guide T250i Congratulations on your purchase of the Sony Ericsson T250i. For additional phone content, go to www.sonyericsson.com/fun. Register now to get free online storage and special offers at
More informationUSER MANUAL V5.0 VT300
GPS Vehicle Tracker USER MANUAL V5.0 VT300 Updated on 26/12/2008 Contents 1 Product Overview 3 2 For Your Safety 3 3 VT300 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2 Light and
More information4-Port Pocket. USB KVM Switch with USB 2.0 Hub
4-Port Pocket USB KVM Switch with USB 2.0 Hub Manual - 1 - Index 1. INTRODUCTION... 3 1.1 FEATURES... 3 1.2 PHYSICAL DIAGRAM... 4 1.3 PACKAGE CONTENTS... 4 2. SPECIFICATIONS... 5 2.1 ERAL... 5 2.2 LED
More informationBusiness/Home. GSM Alarm system
Business/Home GSM Alarm system Installation and Users guide Profile For a better understanding of this product, please read this user manual thoroughly before using it. I. General information: GSM 900/1800/1900
More informationR22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power
R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor
More informationDanfoss Link Mobile Phone Butler
MAKIG MODER LIVIG POSSIBLE Installation Guide www.heating.danfoss.com Table of Contents 1 Introduction... 3 2 Installation... 3 3 Interfaces... 4 4 Wiring... 4 5 SMS Commands... 5 6 Technical Specifications...
More informationcomputer radio control system
extended serie Receivers 1 Introduction GLISH FW. ver. 3.10 Jeti DUPLEX Receivers are designated for use with the DC/DS transmitters or the JETI transmitter modules in the 2,4 GHz frequency band. DUPLEX
More informationGPS/GSM Personal Tracking Device
GPS/GSM Personal Tracking Device User Manual INDEX Usage Packing list Before using Add/Delete/Check Preset Phone Number Change / Check Password Set langue Set SMS locate mode after calling Send a SMS trigger
More informationTMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
More informationPRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: WWW.BRITEQ-LIGHTING.COM TABLE OF CONTENTS
STGE COO 48 Preliminary User Guide Official version will follow soon on: WWW.BITEQ-IGHTIG.COM TBE OF COTETS 1. Safety Instruction 2. Technical Specification 3. How To Set The Unit 4. How To Control The
More information9452/9453 Installation and User Guide
9452/9453 Installation and User Guide Compatible Equipment 9425 Remote Keypad 9040 Internal Sounder 660 Speech Communicator 8440 4-Channel Minicom 496330 Issue 1 1 of 10 9452/3 Introduction The 9452 and
More informationalpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS
alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS Safety precautions Safety precautions The DSL modem alpha DSL WTM HS complies with the European norm EN60950 safety of information technology
More informationGPS Vehicle tracker (Anti-theft Tracking & Positioning) USER MANUAL
GPS Vehicle tracker (Anti-theft Tracking & Positioning) USER MANUAL (Version 2.3) Please read this manual carefully before attempting installation and online activation. Pictures are for indication and
More informationTV-Free TF-PCM31. for Porsche PCM 3.1 navigation systems
TV-Free Video-in-motion Interface for Porsche PCM 3.1 navigation systems Legal Information By law, watching moving pictures while driving is prohibited, the driver must not be distracted. We do not accept
More informationIRIS Touch 600 Range Dialler Installation Manual. Version 1.3
IRIS Touch 600 Range Dialler Installation Manual Version 1.3 The information contained is supplied without liability for any errors or omissions. No part may be reproduced or used except as authorised
More informationPRODUCT MANUAL LUMENTO X4 LED. LED Controller ZN1DI-RGBX4. Program version: 1.0 Manual edition: a
PRODUCT MANUAL LUMENTO X4 LED LED Controller ZN1DI-RGBX4 Program version: 1.0 Manual edition: a INDEX 1. Introduction...3 1.1. Lumento X4... 3 1.2. Installation... 4 2. Configuration...6 3. ETS Parameterization...7
More informationGETTING TO KNOW YOUR TELSTRA PRE-PAID 3G USB + WI-FI
FOR MORE INFORMATION CALL 125 8880 or FROM A NON-TELSTRA PHONE, CALL 13 2200 AND SAY PRE-PAID VISIT telstra.com/ppmbb VISIT A TELSTRA STORE OR PARTNER GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G USB + WI-FI
More informationAUTODIALLER / QUICKDIALLER - SA132
AUTODIALLER / QUICKDIALLER - SA132 INSTRUCTION LEAFLET ENGLISH www.thermomax-group.com CONTENTS 1 SETUP AT A GLANCE... 2 2 FOREWORD....... 3 3 INSTALLATION...... 4 4 KEYPAD AND INDICATORS...... 5 SETTING
More information