GSM Controller BR160GM-Gate

Size: px
Start display at page:

Download "GSM Controller BR160GM-Gate"

Transcription

1 GSM Controller BR160GM-Gate Gate opener version for Gate control. GSM module for SMS remote monitoring and control applications Alarm Notification Remote Control

2 Features Internal quad-band GSM-modem 6 digital input ports 3 Open-Drain MOSFET output ports 1 Power Relay output Error notification using SMS messaging via cell phone Control via SMS Configuration from cell phone Introduction The BieneRemote160GM GSM controller is a communications device that connects used for wireless Alarm Monitoring and Control of remote equipments and systems. Multiple users can interrogate the BieneRemote160GM or be notified on configurable events. The built-in quad-band GM862-quad GSM module compatible with 850/900/1800/1900Mhz GSM networks. BieneRemote160GM-S - Standard version for digital signal monitoring. BieneRemote160GM-4A/2A - Analog version for digital and analog signal monitoring. BieneRemote160GM-SMT - Temperature version for digital signal and temperature monitoring. BieneRemote160GM-GATE - Gate opener version for Gate control.

3 SMS Function SMS controller send an event SMS messages to up to 4 cell phones. Any cell phone can be used to send SMS commands to BieneRemote160GM. Mobile users can contact and request information from a BieneRemote160GM GSM controller and up to 4 users can receive notification of events. With the BieneRemote160GM GSM controller you can use a mobile phone to: Monitor the status of equipment or systems Send control commands to remote equipment Receive notification of events Any BieneRemote160GM GSM controller can be used to send SMS commands to other BieneRemote GSM controller for remote control. Any BieneRemote160GM GSM controller can be programmed via SMS instruction. SMS based remote monitoring and control application Input Signal Monitoring The BieneRemote160GM has 6 voltage-free digital inputs that can be configured as: 0-1 or 1-0 event input each input can with jumper connect to pullup resistor (to +5V or +12V optional) To receive SMS message by event on inputs, you need entering SMS message on a module (or SIM card) programming.

4 Output Control The BieneRemote160GM has 3 open-drain Outputs and 1 Power Relay Output. These may be controlled with SMS messages from approved users. To set any output as you like, you need only to send an SMS message. Module to Module Control The BieneRemote160GM supports Module-to-Module management with SMS command. Users and Administrator The BieneRemote160SM supports up to 3 users. Each user can interrogate the device for the current I/O status. Users can be notified based on changes to each input. Security The BieneRemote160GM has a number of in-built security features. Caller ID security provide authentication for device interrogation and control. Alarm SMS messages can be sent to users when an input reaches an alarm state. The following setpoint configurations are available: Alarm when 0-1 or 1-0 event at digital input. Module Programming/Configuration The BieneRemote160GM can be configured (programming) remotely with SMS command. Configuration options include Alarm Message Content, Users and Administrators Phone Numbers and other.

5 Technical Specification BieneRemote160GM Hardware Specification GSM band support Internal GSM modem RF Transmit Power Command and data transmission SIM card reader SIM card type Antenna Connection Firmware Digital inputs Digital inputs type BR160GM-S BR160GM-4A/-2A BR160GM-SMT BR160GM-GATE GSM850/900/1800/1900 Telit GM862-QUAD Class 4 (2W) 900Mhz, Class 1 (1W) 1800Mhz, 1900Mhz SMS Yes Phase 2 GSM SIM 3V 50Ω SMA (f) Connector Yes Voltage-free, transistor ("0": V; "1": V without external limited resistor); Optional: +12V/+5V pullup resistor for each input - Number of digital inputs Events digital inputs Digital inputs event 0-1 or Digital signal filter 25ms 9sec - Protection Yes Temperature sensor inputs Temperature sensor - - SMT (Smartec) Number of temperature inputs Temperature input event - - min / norm / max - Temperature range to +130 C - Events Temperature range to +130 C Accuracy C - Protection - - Yes - Analog inputs Number of analog inputs - 4 / Protection - yes Analog input event - min / norm / max ADC resolution - 10-bit - - Outputs Number of outputs 4 - MOSFET Open Drain 3 (50V max) outputs - Relay outputs 1 (NO/COM/NC), 28VDC/230AC/ 5A - Digital output control On-Off; Pulse (Standard and Gate version only) Gate Control Call Control Yes Number of user Up to 250 Wiring Wiring Connections Screw terminal blocks Power Supply Required Power supply External +12 VDC stabilized Power requirement 50mA typ, 350mA(rms) max, 2A max. peak during transmission Voltage regulator Internal voltage regulator Power protection Reverse-polarity and overvoltage protection

6 Environmental Conditions Normal operating temperature.range Extreme operational temperature range Storage temperature range Humidity Physical parameter Board dimension Enclosure dimension Box Weight C C (these temperature can affect the sensitivity and performance of the module) -40 to +80 C 0-95% non-condensing 103 x 86.5 mm 106 x 100 x 58 mm DIN-rail mounting BieneRemote160GM Firmware Specification BR160GM-S BR160GM-4A/-2A BR160GM-SMT BR160GM-GATE Number of controlled outputs 4 Number of digital event inputs Number of readable digital inputs Number of analog event inputs Number of readable analog data - 4 / / Authorization cell phone 3 2 / numbers Events cell phone numbers 3 2 / SMS events format Text message SMS digital data format Binary Binary Binary HEX SMS message format for analog data SMS message format for temperature data In % from Reference level º C min level, max level -45º C º C

7 BieneRemote160GM-Gate -Gate Communication Door open, with Access control via GSM 900/1800/1900 or 850/900/1800/1900Mhz Dialing Authorized or not authorized Maximum number of users 250 Identification methode User numbers programming, with Internal GSM modem SIM card reader SIM card type Firmware Users phone number SMS GM862-QUAD Yes Phase 2 GSM SIM 3V Yes Inputs Number of inputs 5 Events Inputs 5 Outputs Number of outputs 4 - Relay outputs 1 (NO, NC, COM; 28VDC/230VAC/5A) - MOSFET transistor outputs 3 *) (50V max) Output signal duration, sec (output 2 and 3) sec (pulse mode) 00 (ON/OFF with dialing - latch mode) Power Supply Required Power supply Power requirement Voltage regulator Power protection External +12 VDC stabilized 50mA typ 350mA (rms) max, 2A peak max. during transmission (rms) Internal voltage regulator Reverse-polarity protection Environmental Conditions Normal operational temperature range Extreme operational temperature range (these temperature can affect the sensitivity and performance of the module) Board dimension C C 103 x 86.5 mm *) Note: One MOSFET output can used as BUZZER output.

8 Hardware The BieneRemote160GM module consists of the microprocessor, voltage regulator, inputs driver, MOSFET output driver, relay, built-in GSM module, GSM antenna connector and screw terminals for external power supply and for input and output signal connection.

9 Power Supply The BieneRemote160GM operates from a 12VDC power source. It draws less then 70mA standby, less then 350mA rms and 2A peak max. 12VDC/1.3A...2A switching stabilized power supply is recommended. Power supply input has reverse polarity and overvoltage protection. SIM Card Small SIM-card with 3V technology Preparation of SIM card 1. Delete any SMS messages from SIM. 2. Disable PIN code request so it will not prompt for a PIN code on turning on. 3. Write 3 authorized numbers to Phone Book (position 1,2,3) You can to position 1 write number 99 or +99 for disable authorization numbers Note: The BieneRemote160GM can only be used with small SIM-cards with 3V technology. For SIM card preparation you can use cell phone or external GSM modem. SIM card change if power turn off. LED indicators Module status indication - RED LED (LED1) GSM Modem SIM300 status indication - GREEN LED (LED2) Module LED indication (Red LED) LED status Permanently off Short blinking after power on and after 1 min periodic blinking Short blinking (period 5-6 sec) Permanently on Modem status Device off SIM card read process Module in work Module work with modem GSM Modem LED indication (Green LED) LED status Permanently off Fast blinking (period 1s, ton 0,5s) Slow blinking (period 3s, ton 0,3s) Permanently on Modem status Device off Net search / Not registered / Turning off Registered full service A call is active

10 Connectors and Jumpers Power supply (X2 - screw terminal block). Controlled equipment inputs and outputs (X2, X3, X4 - screw terminal block) SMA female connector (X5) for GSM antenna connection. Power Supply Connection +12VDC stabilized Power Supply must be connected with screw terminal block. We recommend use stabilized 1,3...2A 12VDC power supply. Power supply input has negative voltage and over voltage protection. Internal +12VDC connection and Power Supply connection schematic. Antenna connection GSM antenna must be connected to SMA connector X5. Use only the 50Om antenna of the necessary frequency range. Base version complected with direct mount GSM antenna. Note: It is very important that the antenna is installed on a location where the GSM-network coverage is sufficient. Please also check carefully that antennas are not installed nearby technical devices, cables etc which could influence the GSM-radiation.

11 Inputs and Outputs connection Digital inputs and outputs must be connected with screw terminal blocks X2-X4. Note: See also "Inputs and Outputs schematic". Connectors For Power supply, Inputs and Outputs connection used screw terminal blocks. +12V - +12VDC Power Supply input / +12VDC output GND - GND INP1...INP6 - Digital Inputs 1-6 AN1...AN4 - Analog Inputs 1-4 (not support in this version) OUT1,OUT2,OUT4 - Output 1, Output 2, Output 4 NO/COM/NC - Relay Output 3 +5V - +5V output (50mA max)

12 Gate Automatic Connection For gate automatic control used relay output: Output 2 - alternative output for gate control. Output 1 and Output 4 - for optional use. Additional Interface Standard 2x3 pin ISP interface connector X1. Used only for in-system microcontroller programming. Pin Pin 1 MISO 2 VCC 3 SCK/ 4 MOSI 5 Reset/ 6 GND

13 Jumpers Jumper J2 Connection pull-up resistor to digital inputs. 2k2 resistor for each inputs is used. All resistor pulled up to +5V (+12V optional). Note: Use this jumper only for Open Collector or Relay Output.

14 Inputs / Outputs Schematic Inputs Digital Transistor Inputs Connector: Screw terminal block Inversion: Yes Protection: Yes Max input voltage: +12V without external limited resistor. Free Input: logic "0" Logic "0": 0V +1V Logic "1": +1.5V +12V J2 jumper for pull-up resistor connections to +12V (+5V optional) 0-10V / 0-5V Analog Inputs Connector: Screw terminal block Input type: CMOS Input Voltage: 0 to +10V Protection: Yes Input resistance: 100 KOm. ADC resolution: 10-bit 249 Om resistor optional for 0-20/4-20mA applications

15 Outputs MOSFET Open Drain Outputs Connector: Screw terminal block MOSFET transistor: Si9945 or IRF7103 Max. Voltage: 50V Relay Output Connector: Screw terminal block Outputs: NO/COM/NC Relay: SPDT power relay Breaking capacity: 5 A 230VAC / 28VDC Min load: 0.1 A, 5VDC

16 Connection Example Connection example to Input Driver (Input 1-5) 1-0 and 0-1 event notification You can use J2 pin header for in-board pull-up resistor connection. Relay connection example to Output Driver (Output 1, 2 and 5) Electromechanical relay connection. Solid-state-relay (SSR) connection.

17 Module programming For module programming: SIM card preparation Programming with send control SMS (see paragraph 'SMS Control Command List') SIM card preparation Delete any SMS messages from SIM. Write alarm SMS message to SIM (if you use alarm function) Disable PIN code request so it will not prompt for a PIN code on turning on. Write 2 authorized numbers to Phone Book (position 1,2) Write gate open user cell phone numbers to Phone Book (position from 3); you can added and deleted numbers with SMS command. Note: The module can only be used with small SIM-cards with 3V technology. For SIM card preparation you can use cell phone or external GSM modem. Set phone numbers from which management (module settings, add/delete SMS phone book) is authorized Phone Book 1 A1 <Phone number1> 1) 2 A2 <Phone number2> 1) 1): full phone number with country code (see Note below) Example: enable 2 phone numbers for module management Phone Book 1 A A Example: enable all phone numbers (disable authorization numbers; all cell phone enabled for gate open) Phone Book 1 A A2 <Phone number2> NOTE: For difference mobile operators can be difference number format in CLIP. For example for Latvia BITE and LMT TELE (without country code) Also for difference country can be difference number format in CLIP for UK: At position 001 and 002 you should write number with country code ( ) At position you should write number without country code ( )

18 Phone Book in SIM and EEPROM Phone Book stored in SIM and in EEPROM BR160GM-GATE module. After restart module Phone Book from SIM card copy to EEPROM. After SMS command ADDNUM number added to Phone Book in EEPROM and in SIM card. After SMS command DELNUM number deleted from Phone Book in EEPROM and from SIM. You can write numbers to SIM Phone Book directly Phone Book 001 A1 <Phone number 1> 002 A2 <Phone number 2> 003 A3 <Phone number 3> A249 <Phone number 2490> 250 A250 <Phone number 250> Number at location 001 and 002 Number at location 001 and privileg.number: from this cell phone you can send SMS command for setting and control. - numbers, enabled for gate open process. If at location 001 empty or short number, for example 001 or 99, then all cell phone enabled for gate open process. You can write numbers to SIM Phone Book. with SMS command ADDNUM or deleted number from SIM Phone Book with SMS command DELNUM You can add new number to phone book ADDNUM SMS command. - If phone book full, you receive answer SMS 'SIM Phone Book Full' - If phone book not full, new number entered to first empty position in phone book you receive SMS 'NR added' (you receive also position in phone book) - If number exist in phone book, you receive SMS 'NR exist' (number exist in phone book at position 042) - If number not exist in phone book, you receive SMS 'NR added' (number added at position 250) You can delete new number from phone book DELNUM SMS command. - If number not exist in phone book, you receive answer SMS 'NR not exist' - If number exist in phone book, you receive answer SMS 'NR deleted' You can read number from phone book GETNUM SMS command. New SMS command Maxnn1 Maxnn9 Maxnn1 30 numbers maximum; Maxnn2 60 numbers maximum (default setting) Maxnn8 240 numbers maximum; Maxnn9 250 numbers maximum

19 Example: ADDNUM Phone Book 001 A1 <Phone number 1> 002 A2 <Phone number 2> 003 A3 <Phone number 3> A250 <Phone number 250> DELNUM Phone Book 001 A1 <Phone number 1> 002 A2 <Phone number 2> 003 A3 <Phone number 3> A250 <Phone number 250> Add number to SIM phone book ADDNUM or Addnum add number to SIM phone book - add number to SIM phone book Answer SMS: NR added - if number added to SIM phone book at location 012 NR exist - if number exist in SIM phone book at location 012 where: NR location in SIM phone book NOTE: For difference mobile operators can be difference number format in CLIP. For example for Latvia BITE and LMT TELE (without country code) Also for difference country can be difference number format in CLIP for UK: At position 001 and 002 you should write number with country code ( ) At position you should write number without country code ( )

20 Delete number from SIM phone book DELNUM or Delnum delete number from SIM phone book - delete number from SIM phone book Answer SMS: NR deleted - if number deleted from SIM phone book (from position 011) NR not exist - if number not exist in SIM phone book where: NR location in SIM phone book Read number from phone book GETNUM read number from SIM phone book with location 051 Answer SMS: NR 051: Note: - If in your cell phone in phone book phone number exist with name, for example, BIENE, your cell phone display following answer SMS: NR 11 BIENE deleted NR 001: BIENE NR 12 BIENE added Set output impulse duration (accuracy +/- 20%) SETDD 12 SETDD 90 SETDD 00 SETDD 02 SETDD 00 - set duration = 12 sec - set duration = 90 sec - disable output impulse - latch mode - set pulse duration = 2 sec - disable pulse latch mode

21 Remote control You can with dialing (without connection) open your gate. Output 3 and Output 2 for gate control. We can turn on and turn off module outputs with SMS command: SETOU and RSTOU. SETOU1 RSTOU1 - set output 1 to '0' - active state. - reset output 1 to '1' - passive state. Answer SMS: INP=3F OUT=00 Pulse (sec) 5 where: INP=3F OUT=00 Pulse (sec) - input state in HEX (inverse to inputs on terminal block) - output state (output 4..1) in HEX - output impulse duration (in sec) If Pulse = 00 (see SMS command Setdd), then latch mode. First dial - turn on, second dial - turn off

22 SMS Control Command List Control Command List Command Function Return Message Description 1) Read Status Getst Get Status INP=3F OUT=00 Pulse (sec) 5 Input and output state, pulse duration (output 3) Outputs control Setou1 Set Output 1 - Set Output 1 Setou2 Set Output 2 - Set Output 2 Setou3 Set Output 3 - Set Output 3 - relay ON Rstou1 Reset Output 1 - Reset Output 1 Rstou2 Reset Output 2 - Reset Output 2 Rstou3 Reset Output 3 - Reset Output 3 - relay OFF Setdd NN Addnum Delnum Set output impulse duration Add new number Delete number Settings INP=3F OUT=00 Pulse (sec) 5 Phone Book Settings NR added or NR exist NR deleted or NR not exist Getnum Read number NR 167: Set output impulse duration, NN = sec.; default 02 if NN=00, then latch mode ADDNUM DELNUM GETNUM location in SIM phone book Rstart Restart Restart (module work after 2 min) MaxnnN Set Max numbers note: This SMS command support only new version software INP=3F OUT=00 Pulse (sec) 5 MaxNN=60 N from 1 to 9 N=1 30 numbers N=2 60 numbers (default)... N=8 240 Numbers N=9 250 numbers Note: 1): Not case sensitive. You can use GETNUM, Getnum, SMS command module executed after 60 sec maximum. If you change first number in SIM phone book, required restart module for new installation.

23 SMS Reporting Message (Alarm SMS in SIM) SMS Message Number in SIM SMS Message Cell Phone Number Input NR 1 Event 1 <Phone number> 1 2 Event 2 <Phone number> 2 3 Event 3 <Phone number> 3 4 Event 4 <Phone number> 4 5 Event 5 <Phone number> 5 Example SMS Message Cell Phone Input Nr Text of Messages Number Number Connected to 1 Door open <Phone number> 1 Door sensor 2 Smoke detection <Phone number> 2 Smoke detectors 3 <Phone number> 3 4 <Phone number> 4 Not connected input state Input state Status data INP= Input state with connected pull-up resistor (J2) Input Input Input Input Input Input Active event on input Input state Input Input Input Input Input 5 1-0

24 Output state Output state Output state Status data OUT= Output 1 Open Drain 1 1 Output 2 Open Drain 1 1 Output 3 Relay NO 1 1 Output 4 Open Drain 1 1 Phone numbers from which management is authorized (optional) Delete all entry in active phone book and write 3 phone numbers of mobile phone. Phone Book 1 A1 <Phone number1> 2 A2 <Phone number2> 3 A3 <Phone number3> Note 1: full phone number with country code Example - enable 2 phone numbers for module management (A1 and A2); for gate open enable only number in SIM phone book (max. 250 numbers) Phone Book 1 A A A Example - enable all numbers (disable authorization numbers); all number enabled for gate open. Phone Book 1 A A2 <Phone number2>

25 Support Biene Electronics SIA Riga, Latvia Please send your comments, suggestions and bug reports to

GSM Controller BR160SM-2SMT-4A-A / BR161SM-2SMT-4A-A

GSM Controller BR160SM-2SMT-4A-A / BR161SM-2SMT-4A-A GSM Controller BR16SM-2SMT-4A-A / BR161SM-2SMT-4A-A Temperature, analog and digital version for green energy equipments. GSM module for SMS remote monitoring and control applications Features Internal

More information

GSMPBX version 1.3 Datasheet

GSMPBX version 1.3 Datasheet GSMPBX version.3 Datasheet Document Rev.:.3 Revision Date: 23.03.203 (preliminary data) Figure - GSMPBX Introduction The GSMPBX is designed to commute phone calls between a cellular network (GSM) and the

More information

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature

More information

SMS GSM Alarm Messenger

SMS GSM Alarm Messenger SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up

More information

GSM Voice Auto Dialer & SMS Sender JC-999

GSM Voice Auto Dialer & SMS Sender JC-999 GSM Voice Auto Dialer & SMS Sender JC-999 Main features: () Large LCD display,integrated integrated keypad, human-friendly programming; (2) Support 2 alarm receiving numbers; (3) Triggering means: N.C

More information

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS

More information

USER MANUAL V5.0 ST100

USER MANUAL V5.0 ST100 GPS Vehicle Tracker USER MANUAL V5.0 ST100 Updated on 15 September 2009-1 - Contents 1 Product Overview 3 2 For Your Safety 3 3 ST100 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2

More information

Temperature & Humidity SMS Alert Controller

Temperature & Humidity SMS Alert Controller Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal

More information

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation

More information

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO GSM-PRO GSM-PRO perfect for communication CONTA-CLIP s GSM-PRO module offers a remote control and maintenance solution which allows you to monitor and control decentralized facilities. The GSM-PRO module

More information

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014 EZmoto V2 Product description Rev. 6 10/01/2014 1 Contents 1. Overview... 3 2. Hardware Interface Description... 3 2.1 Main features of the EZmoto... 3 2.2 Hardware block diagram... 4 2.3 Internal Hardware

More information

ABB Drives. User s Manual HTL Encoder Interface FEN-31

ABB Drives. User s Manual HTL Encoder Interface FEN-31 ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

MANUAL GSM CONTROLLER

MANUAL GSM CONTROLLER MANUAL GSM CONTROLLER CallFree2 CallFree 3G 2 outputs, 3 inputs ` Please read these instructions completely before use GSM CallFree 1/17 Revision V1.3C, Aug 2015 TABLE OF CONTENTS 1. SAFETY PRECAUTIONS...

More information

GPS/GLONASS SiRFstarV Evaluation Kit EVA5100-A

GPS/GLONASS SiRFstarV Evaluation Kit EVA5100-A GPS/GLONASS SiRFstarV Evaluation Kit EVA5100-A A Description of the Evaluation Board for Maestro s GPS/GLONASS Receiver Module A5100-A User s Manual Version 0.1 Revision History Rev. Date Description 0.1

More information

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CGWTS-M001A Version 1, Release 1, December 2004 NOTICE

More information

How To Use An Adh8012 Gsm Gprs Module With A Gsm 2.2.2 (Gsm) Gpros (Gsp) Gpls (Geo) Gsp (Gpl) Gs

How To Use An Adh8012 Gsm Gprs Module With A Gsm 2.2.2 (Gsm) Gpros (Gsp) Gpls (Geo) Gsp (Gpl) Gs ADH Technology Co. Ltd. ADH8012 GSM GPRS Modem User s Manual www.adh-tech.com.tw sales@adh-tech.com.tw Page 1 Content ADH8012 GSM GPRS Modem User s Manual... 1 1. Introduction... 3 2. Product concept...

More information

Intelligent GSM Auto-dial Alarm System User s Manual

Intelligent GSM Auto-dial Alarm System User s Manual Intelligent GSM Auto-dial Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. [Function Instruction] [Control Panel Introduction]

More information

GTR-128/GTR-129 Motorcycle/ Vehicle Tracker Quick Start Guide

GTR-128/GTR-129 Motorcycle/ Vehicle Tracker Quick Start Guide GTR-128/GTR-129 Motorcycle/ Vehicle Tracker Quick Start Guide GlobalSat WorldCom Corporation 16F., No. 186, Jian 1 st Rd, Zhonghe Dist., New Taipei City 23553, Taiwan Tel: 886.2.8226.3799/ Fax: 886.2.8226.3899

More information

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK Security Door Controls 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP

More information

Technical description MX-1 VB Edge

Technical description MX-1 VB Edge 1 (7) Technical description MX-1 VB Edge 2 (7) Table of Contents 1 General description...3 2 Connectors...4 3 ON/OFF operation...5 4 Power...5 5 LED indicators...6 6 Enclosure...6 7 Mounting...6 8 and

More information

GTS-4E Hardware User Manual. Version: V1.1.0 Date: 2013-12-04

GTS-4E Hardware User Manual. Version: V1.1.0 Date: 2013-12-04 GTS-4E Hardware User Manual Version: V1.1.0 Date: 2013-12-04 Confidential Material This document contains information highly confidential to Fibocom Wireless Inc. (Fibocom). Fibocom offers this information

More information

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

TX GSM SMS Auto-dial Alarm System. Installation and User Manual TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses

More information

LOW COST GSM MODEM. Description. Part Number

LOW COST GSM MODEM. Description. Part Number Dual Band 900 / 1800 MHz Fax, SMS and Data Integral SIM Card holder Siemens TC-35i GSM Engine Rugged Extruded Aluminium Enclosure Compact Form Factor 86 x 54 x 25mm RS232 Interface with Auto baud rate

More information

Data Sheet. Adaptive Design ltd. Arduino Dual L6470 Stepper Motor Shield V1.0. 20 th November 2012. L6470 Stepper Motor Shield

Data Sheet. Adaptive Design ltd. Arduino Dual L6470 Stepper Motor Shield V1.0. 20 th November 2012. L6470 Stepper Motor Shield Arduino Dual L6470 Stepper Motor Shield Data Sheet Adaptive Design ltd V1.0 20 th November 2012 Adaptive Design ltd. Page 1 General Description The Arduino stepper motor shield is based on L6470 microstepping

More information

Allen-Bradley/Rockwell

Allen-Bradley/Rockwell MANUFACTURER DATA SHEET High Speed Counter Manufacturer: Allen-radley/Rockwell Model Number: 1746-HSCE See www.geomartin.com for additional PDF datasheets Martin Part Number: E-014901-03 VendorPartNumber:

More information

Bluetooth UART/RS232 Module

Bluetooth UART/RS232 Module Introduction BLUEMORE600 is a professional, slim, wireless module ready for integration in brand new or existing electronic products. Based on CSR chipset BC03MM it s fully compatible for Serial Port profiles.

More information

Business/Home GSM Alarm System. Installation and User Manual

Business/Home GSM Alarm System. Installation and User Manual Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene

More information

GSM Gate Control 1000

GSM Gate Control 1000 GSM Gate Control 000 INSTALLATION AND APPLICATION MANUAL for module version v3.3 and higher Manual version:.7 24.06.20 Features: Control of relay outputs with free calls using caller identification Capacity

More information

USB I/O CONTROL BOX 8 relays, 8 digital I/O lines and 8 HV inputs

USB I/O CONTROL BOX 8 relays, 8 digital I/O lines and 8 HV inputs USB I/O CONTROL BOX 8 relays, 8 digital I/O lines and 8 HV inputs The Big Deal USB HID device compatible with 32/64 Bit operating systems 8 TTL/LVTTL digital I/O channels, 8 High Voltage digital inputs

More information

FM4100 USER MANUAL V1.4

FM4100 USER MANUAL V1.4 FM4100 USER MANUAL V1.4 Table of Contents ATTENTION!... 2 INSTRUCTIONS OF SAFETY... 3 LEGAL NOTICE... 4 Short description...5 1.1 About the document... 5 1.2 Acronyms... 5 1.3 Mounting guidelines... 5

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

C2O CALL 2 OPEN USING YOUR CELL PHONE. Operation. Features Ready to operate Straight from the Box! O/P Changeover Contact 1.2KW

C2O CALL 2 OPEN USING YOUR CELL PHONE. Operation. Features Ready to operate Straight from the Box! O/P Changeover Contact 1.2KW CALL 2 OPEN USING YOUR CELL PHONE Features Ready to operate Straight from the Box! O/P Changeover Contact 1.2KW White List upto 10 Tel No s Signal Strength Indication Internal Antenna Waterproof Enclosure

More information

Model: DC-A2IO Advanced HVAC Controller

Model: DC-A2IO Advanced HVAC Controller Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA

More information

KTA-223 Arduino Compatible Relay Controller

KTA-223 Arduino Compatible Relay Controller 8 Relay Outputs 5A 250VAC 4 Opto-Isolated Inputs 5-30VDC 3 Analog Inputs (10 bit) Connections via Pluggable Screw Terminals 0-5V or 0-20mA Analog Inputs, Jumper Selectable 5A Relay Switching Power Indicator

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

GSM HOME SECURITY SYSTEM

GSM HOME SECURITY SYSTEM Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : GSM-120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5.

More information

Part Number Description Packages available

Part Number Description Packages available Features 3 digital I/O Serial Data output Connects directly to RF Modules Easy Enc / Dec Pairing Function Minimal External Components Required Performs all encoding/decoding of data for Reliable Operation.

More information

UniPi technical documentation REV 1.1

UniPi technical documentation REV 1.1 technical documentation REV 1.1 Contents Overview... 2 Description... 3 GPIO port map... 4 Power Requirements... 5 Connecting Raspberry Pi to UniPi... 5 Building blocks... 5 Relays... 5 Digital Inputs...

More information

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided. Preliminary TECHNICAL DATASHEET #TDAX020700 HYDRAULIC VALVE CONTROLLER 24 I/O 5 Analog and 6 Digital Inputs 1 Temperature Sensor and 1 RPM Sensor Interface 2 PWM Inputs 6 Proportional and 4 ON/OFF Current

More information

Always on the Lookout Perfect Protection against Burglary

Always on the Lookout Perfect Protection against Burglary Always on the Lookout Perfect Protection against Burglary Terxon wired and hybrid alarm systems One system offers all possibilities Rely on experts With a qualified specialist installation contractor on

More information

Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide

Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide Sensors LCD Real Time Clock/ Calendar DC Motors Buzzer LED dimming Relay control I2C-FLEXEL PS2 Keyboards Servo Motors IR Remote Control

More information

IDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited

IDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited (Rev. 1.0) China Aerospace Telecommunications Limited Contents 1. Introduction......3 2. Specifications...4 2.1 External Interface... 4 2.2 Status Indicator...... 5 2.3 Technical Parameters... 6 3. Device

More information

Roadstar Installation Instruction Manual

Roadstar Installation Instruction Manual Roadstar Installation Instruction Manual This instruction manual describes installation of GPS/GPRS vehicle tracking device Roadstar. Modem is already set to work with system for vehicle tracking, and

More information

GPS Vehicle and personal location tracker. User manual

GPS Vehicle and personal location tracker. User manual GPS Vehicle and personal location tracker User manual 1 Contents 1. Product overview... 2 2. Safety instruction... 3 3. Specification and parameters... 3 4. Getting started... 4 4.1 Hardware and accessories...

More information

DS1721 2-Wire Digital Thermometer and Thermostat

DS1721 2-Wire Digital Thermometer and Thermostat www.dalsemi.com FEATURES Temperature measurements require no external components with ±1 C accuracy Measures temperatures from -55 C to +125 C; Fahrenheit equivalent is -67 F to +257 F Temperature resolution

More information

T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: 2004-07-16 Version 1.0

T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: 2004-07-16 Version 1.0 T-BOXN12R You can make it wireless First steps with T-BOXN12R Date: 2004-07-16 Version 1.0 Content 1. Purpose of this document... 3 2. T-BoxN12R overview... 4 3. First step... 5 3.1. Preparing your workshop

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

Talon and Talon SR User Manual

Talon and Talon SR User Manual Talon and Talon SR User Manual Brushed DC motor controller Version 1.3 Cross the Road Electronics, LLC www.crosstheroadelectronics.com Cross The Road Electronics, LLC Page 1 4/2/2013 Device Overview Clear,

More information

TELULAR SX4E PHONECELL WITH THE 8210 SPEECH MODEM APPLICATION NOTE

TELULAR SX4E PHONECELL WITH THE 8210 SPEECH MODEM APPLICATION NOTE TELULAR SX4E PHONECELL WITH THE 8210 SPEECH MODEM APPLICATION NOTE September 2004 Prepared by: Integrated Systems Division The Sutron Corporation 21300 Ridgetop Circle Sterling, VA 20166 Copyright 2004

More information

RS - SPM. Serial parallel translator module

RS - SPM. Serial parallel translator module ReSatron GmbH Boisheimer Str. 162 D-41751 Viersen Telefon (+49) 02162-45 06 80 Telefax (+49) 02162-45 03 04 email: info@resatron.de RS - SPM Serial parallel translator module RSSPM000215SPM-021 - Subject

More information

WICE-SPI Hardware Operation Manual

WICE-SPI Hardware Operation Manual Contents 1.Hardware Instruction...1 2. Pin Definition Of WICE-SPI Connector...2 3. Peripheral Circuit Arrangements...3 4. On-Board Programming...4 5. Off-Line Programming...8 1.Hardware Instruction 1.WICE-SPI

More information

Unidirectional Transmitter/ Receiver Units Introduction

Unidirectional Transmitter/ Receiver Units Introduction Unidirectional Transmitter/ Receiver Units Introduction Wireless Input/Output (I/O) connects directly to analog, discrete and pulse transducer signals. The signals are transmitted by radio and either re-created

More information

GSM AUTO-DIALER With 10Amp Relay USER GUIDE

GSM AUTO-DIALER With 10Amp Relay USER GUIDE GSM AUTO-DIALER With 10Amp Relay USER GUIDE GSM Frequency: Quad band freq 850/900/1800/1900 MHz Power Supply Voltage: 9-18Vdc 1Amp max Current used in standby mode: 25mA max IP 65 Enclosure rating for

More information

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS Vehicle or Personal Position Tracking Vehicle Status and Speed Tracking Auto Accident Report Global Position System (GPS) Navigation System Anti theft Alarm System Overview 1. GPS data tracking via GSM

More information

2014 GSM SHIELD COMPATIBLE WITH ARDUINO GSM SHIELD USING SIMCOMM (SIM900A)

2014 GSM SHIELD COMPATIBLE WITH ARDUINO GSM SHIELD USING SIMCOMM (SIM900A) 2014 GSM SHIELD COMPATIBLE WITH ARDUINO GSM SHIELD USING SIMCOMM (SIM900A) Contents 1 Description... 3 1.1 SIM900... 5 1.2 Features... 6 1.3 Specifications for Fax... 6 1.4 Specifications for SMS via GSM/GPRS...

More information

HORNET Remote Control Systems

HORNET Remote Control Systems HORNET Remote Control Systems Up to 100metres Range 1 3 Button versions 12-30Vdc 0r 230Vac versions Reliable FM Technology Up to four 1000W Relay switches Waterproof Receiver (IP68) Momentary or Latching

More information

Installation manual. Generator Paralleling Controller GPC multi-line 2 4189340225C

Installation manual. Generator Paralleling Controller GPC multi-line 2 4189340225C Installation manual Generator Paralleling Controller GPC multi-line 2 Software ver. 1.3X Compact system in one unit - dynamic synchronisation - load sharing - generator protection DEIF A/S 3-phase AC RMS

More information

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.

More information

RN-WIFLY-EVAL-UM. WiFly Evaluation Kit. 2012 Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM Version 1.32r 10/9/2012 USER MANUAL

RN-WIFLY-EVAL-UM. WiFly Evaluation Kit. 2012 Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM Version 1.32r 10/9/2012 USER MANUAL WiFly Evaluation Kit 2012 Roving Networks. All rights reserved. Version 1.32r 10/9/2012 USER MANUAL OVERVIEW This document describes the hardware and software setup for Roving Networks evaluation kits,

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

MANUAL FOR RX700 LR and NR

MANUAL FOR RX700 LR and NR MANUAL FOR RX700 LR and NR 2013, November 11 Revision/ updates Date, updates, and person Revision 1.2 03-12-2013, By Patrick M Affected pages, ETC ALL Content Revision/ updates... 1 Preface... 2 Technical

More information

MicroMag3 3-Axis Magnetic Sensor Module

MicroMag3 3-Axis Magnetic Sensor Module 1008121 R01 April 2005 MicroMag3 3-Axis Magnetic Sensor Module General Description The MicroMag3 is an integrated 3-axis magnetic field sensing module designed to aid in evaluation and prototyping of PNI

More information

The modular concept of the MPA-3 system is designed to enable easy accommodation to a huge variety of experimental requirements.

The modular concept of the MPA-3 system is designed to enable easy accommodation to a huge variety of experimental requirements. HARDWARE DESCRIPTION The modular concept of the MPA-3 system is designed to enable easy accommodation to a huge variety of experimental requirements. BASE MODULE GO LINE Digital I/O 8 Analog Out AUX 1

More information

Ordering Part Numbers:

Ordering Part Numbers: TECHNICAL DATASHEET #TDAX021500 HYDRAULIC FAN CONTROLLER Application Platform 3 erature Sensors 4 Digital Command Interfaces 1 PWM Input and 1 Analog Input 1 Proportional or ON/OFF Current Output RS232

More information

USB-QUAD08. Eight-channel Quadrature Encoder Input Device. Specifications

USB-QUAD08. Eight-channel Quadrature Encoder Input Device. Specifications Eight-channel Quadrature Encoder Input Device s Document Revision 1.1 May 2012 Copyright 2012 s All specifications are subject to change without notice. Typical for 25 C unless otherwise specified. s in

More information

GSM AUTO DIALER. Remote Monitoring & Control using your mobile phone. www.gsm-activate.co.uk

GSM AUTO DIALER. Remote Monitoring & Control using your mobile phone. www.gsm-activate.co.uk GSM AUTO DIALER Remote Monitoring & Control using your mobile phone www.gsm-activate.co.uk Product Information Our GSM Auto-Dialer is a versatile unit which can be attached to many of your electronic devices

More information

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V] FG085 minidds Function Generator Manual of Operation Applicable Models: 08501, 08501K, 08502K, 08503, 08503K Applicable Firmware Version: 1 ) 113-08501-100 or later (for U5) 2 ) 113-08502-030 or later

More information

GSM Interfacing Board

GSM Interfacing Board Campus Component Pvt. Ltd. DISCLAIMER Information furnished is believed to be accurate and reliable at the time of publication. However, Campus Component Pvt. Ltd. assumes no responsibility arising from

More information

UM0272 User manual. Central Unit for Alarm System (CUAS) Evaluation Board. Introduction

UM0272 User manual. Central Unit for Alarm System (CUAS) Evaluation Board. Introduction User manual Central Unit for Alarm System (CUAS) Evaluation Board Introduction The Central Unit for Alarm System (CUAS) Evaluation Board provides a complete reference system addressing the low- to middle-end

More information

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850

More information

Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003)

Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003) CN2HK LIMITED Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003) User Manual Please read this manual before operating this product. After you finish reading this manual,

More information

RC2200DK Demonstration Kit User Manual

RC2200DK Demonstration Kit User Manual Demonstration Kit User Manual Table of contents TABLE OF CONTENTS... 1 QUICK INTRODUCTION... 2 INTRODUCTION... 3 DEMONSTRATION BOARD... 4 POWER SUPPLY SECTION... 5 RS-232 INTERFACE... 6 CONNECTORS... 7

More information

SVC400P/SVC800P. 4/8 Camera Live Tracking Vehicle DVR Installation Manual. Version 1.0

SVC400P/SVC800P. 4/8 Camera Live Tracking Vehicle DVR Installation Manual. Version 1.0 SVC400P/SVC800P 4/8 Camera Live Tracking Vehicle DVR Installation Manual Version 1.0 1. MAIN FEATURES... 2 2. PRODUCT OVERVIEW... 2 3. DIMENSIONS... 4 4. PACKAGE CONTENTS... 5 5. MOUNTING AND ENVORNMENTAL

More information

Multifunction devices

Multifunction devices devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2

More information

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter Description: The NTE2053 is a CMOS 8 bit successive approximation Analog to Digital converter in a 20 Lead DIP type package which uses a differential

More information

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11 Communication Unit 560CMD11 The SLC works as master for the RTU560 serial peripheral bus (I/O-Interface/ Wired-OR-Bus ). The MPU is responsible for the other tasks. The MPU handles the absolute time and

More information

LMU-5000. Hardware and Installation Guide

LMU-5000. Hardware and Installation Guide LMU-5000 Hardware and Installation Guide Plan The Installation Verify Power, Ground and Ignition. Be sure to check each source (power, ground and ignition) to ensure that the proper signaling exists. This

More information

Silvertel. Ag5200. 1 Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

Silvertel. Ag5200. 1 Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power Silvertel V1.1 November 2012 Datasheet Pb 1 Features IEEE802.3at and IEEE802.3af compliant Maximum 30W output power Dual In-Line (DIL) package size 50.6mm (L) x 30mm (W) Overload, short-circuit and thermal

More information

GSM Gate Opener GSM Remote Switch RTU5015 User Manual

GSM Gate Opener GSM Remote Switch RTU5015 User Manual GSM Gate, Barrier, Shutter, Garage Door and Door opener Open gate or garage door with a FREE call from your mobile phone! Remote switching machines with a FREE call from your mobile phone! GSM Gate Opener

More information

Elvey is a leading distributor of electronic security equipment in Africa. Our vision is to assist in the protection of people and property by

Elvey is a leading distributor of electronic security equipment in Africa. Our vision is to assist in the protection of people and property by Elvey is a leading distributor of electronic security equipment in Africa. Our vision is to assist in the protection of people and property by providing quality, innovative products and solutions to the

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

MEITRACK T1 User Guide

MEITRACK T1 User Guide MEITRACK T1 User Guide Change History File Name MEITRACK T1 User Guide Created By Kyle Lv Project T1 Creation Date Update Date 2014-06-10 2015-05-28 Subproject User Guide Total Pages 18 Version V2.4 Confidential

More information

FWT-8848 GSM (GATEWAY) USER S MANUAL

FWT-8848 GSM (GATEWAY) USER S MANUAL FWT-8848 GSM (GATEWAY) USER S MANUAL COPYRIGHT -2009 1 ST VERSION 1 1,General Description: FWT-8848 is a GSM to Analog Converter(single port,insert 1 sim card only), the device can produce a FXS line to

More information

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000. NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24

More information

WIRELESS MAGNETIC CONTACT

WIRELESS MAGNETIC CONTACT WIRELESS MAGNETIC CONTACT The magnetic contact wireless MAG HCS is a sensor able to detect opening or closing doors or windows and transmits via radio a alarm signal. It is composed of two distinct elements:

More information

Users Manual of GSM Home Alarm System with Photo-taken

Users Manual of GSM Home Alarm System with Photo-taken GSM-IV REMOTE CAMERA MANNAL The Excellent GSM + Camera alarm system bases on the GSM network, integrates the communication technology, can automatic screen a photo with the intruder or burglar, and send

More information

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01 ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions

More information

GSM home alarm system s manual

GSM home alarm system s manual GSM home alarm system s manual I. Main features: 1, Eight wireless LED zone, and four wired zone 2, Two-way to communication 3, The system supports the GSM cell phones, no need the fixed telephone line.

More information

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 Standalone door control module PK-01 Firmware version 1.00 pk-01_en 06/12 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.eu WARNINGS Read carefully

More information

RDF1. RF Receiver Decoder. Features. Applications. Description. Ordering Information. Part Number Description Packages available

RDF1. RF Receiver Decoder. Features. Applications. Description. Ordering Information. Part Number Description Packages available RDF1 RF Receiver Decoder Features Complete FM Receiver and Decoder. Small Form Factor Range up to 200 Metres* Easy Learn Transmitter Feature. Learns 40 transmitter Switches 4 Digital and 1 Serial Data

More information

New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.

New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it. New GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Chapter 1. Features Chapter 2. Alarm Host Introduction Chapter

More information

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions

More information

INSTRUCTION. The smallest GPS watch locator in the country

INSTRUCTION. The smallest GPS watch locator in the country Please read the user manual carefully before you use it, so that you can get the correct installation and make quick online activation. Product appearance and color are subject to change. Actual product

More information

DS1621 Digital Thermometer and Thermostat

DS1621 Digital Thermometer and Thermostat www.maxim-ic.com FEATURES Temperature measurements require no external components Measures temperatures from -55 C to +125 C in 0.5 C increments. Fahrenheit equivalent is -67 F to 257 F in 0.9 F increments

More information

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB. 7I29 MANUAL Rev 1.5 CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB. THE 7I29 IS INTENDED FOR USE BY OEMS THAT WILL INTEGRATE IT INTO A SYSTEM WITH INTERLOCKS AND

More information

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual DMX-K-DRV Integrated Step Motor Driver + (Basic Controller) Manual DMX-K-DRV Manual page 1 rev 1.33 COPYRIGHT 2007 ARCUS, ALL RIGHTS RESERVED First edition, June 2007 ARCUS TECHNOLOGY copyrights this document.

More information