Modicon Momentum automation platform. Catalog

Size: px
Start display at page:

Download "Modicon Momentum automation platform. Catalog"

Transcription

1 Catalog 0

2

3

4 A full range of catalogs for Catalog 00 Detection Automation Automation Operator dialog Motion and Drives & Global Detection Electronic and electromechanical sensors MKTED00EN Photo-electric sensors Proximity sensors Capacitive proximity sensors Ultrasonic sensors Limit switches Pressure switches Rotary encoders Radio frequency identification Machine cabling accessories & Modicon Quantum Catalog 00 MKTED00EN-US Safety PLCs Safety CPUs Unity Concept and ProWORX software & Modicon Premium Catalog 00 MKTED00EN-US Unity processors PL processors Communication software & Modicon M0 Catalog 00 DIAED000EN-US PLCs Discrete, analog I/O and application-specific solutions Communication & Catalog 00 MKTED00EN-US & Twido programmable controller and TwidoSuite software DIAED000EN Controller base Discrete, analog I/O Communication & Automation functions, relays, interfaces and power supplies MKTED00EN Smart relays Timing relays Measurement & control relays Analog interfaces Counters Plug-in relays Interfaces for discrete signals Power supplies & transformers Software PLCs and safety controllers programming software & Control and signalling components MKTED00EN Control and signalling units Control stations & enclosures Cam switches Beacons and indicator banks Pendant control stations Controllers Emergency stops Foot switches & Magelis Human/Machine Interfaces Catalog 00 MKTED00EN-US Operator interface terminals Industrial PCs HMI and SCADA PC-based software Software Vijeo Designer Operator terminal software & Lexium Servo Drives motion control Catalog 00/00 DIAED000EN-US Motion controllers Servo drives and Servo motors Stepper motors and drives Integrated drives Modicon Premium motion control modules & Soft starters and variable speed drives MKTED0EN Soft starters and variable speed drives Software Software for drives Motor control programming software Some products shown in this catalog are not available in every country. Check individual country s web site or Sales Office for product availability. See our web site:

5 ..... Automation & Control functions Motor control Machine safety Interfaces and I/O Power supplies Systems & architectures & Motor starter solutions Control and protection components MKTED00EN Contactors Circuit-breakers, carriers Thermal relays Combinations, motor controllers Mounting solutions Motor starter mounting kits This catalog contains Automation and Control function products relating to machines Safety & Preventa Machine Safety Products Catalog 00 MKTED00EN-US Safety PLCs Safety controllers Safety monitors Safety solutions on AS-Interface cabling system Safety switches Safety light curtains Safety mats Emergency stops Control stations Enabling switches Foot switches Beacons & indicator banks Switch disconnectors Thermal-magnetic motor circuit breakers Enclosed D.O.L. starters & Terminal blocks MKTED00EN Terminal blocks Cable ends & Modicon STB IP 0 distributed inputs/outputs Catalog 00 MKTED00EN-US Modules for automation station Network interfaces Power distribution Digital I/O, analogs and application-specific Software STB configuration software & Phaseo power supplies and transformers DIAED00EN Switch mode power supplies Filtered rectified power supplies Transformers This catalog contains Automation and Control function products relating to Communication & Machine & Installations with industrial communication MKTED00EN Preferred implementations Ethernet TCP/IP, the universal communication standard CANopen for machines and installations AS-Interface, simple and ASI-Safe Products Human-Machine interface Controllers and PLCs Field devices Infrastructure and wiring Gateways Software and tools Collaborative Automation Partner Program & Partners Software XPSMFWIN configuration software XPSMCWIN configuration software

6 Contents b Introduction Discrete I/O bases Selection guide... b Introduction, description... b Specifications b References b Dimensions, mounting... 0 b Wiring diagrams... 0 Analog I/O bases Selection guide... b Introduction, description... b Specifications b References b Dimensions, mounting... b Wiring diagrams... Specialty module I/O bases Selection guide... b Introduction, description... 0 b Specifications b References b Wiring diagrams... Communication adapters Selection guide... b Ethernet TCP/IP network communication adapters b Modbus Plus network communication adapters... 0 b FIPIO bus communication adapters... b In t e rbu s bus communication adapters b Profibus DP bus communication adapter... 0

7 M/ME processor adapters and option adapters Processor adapters selection guide b M/ME processor adapters v Introduction v Description... v Specifications... v References... Option adapters selection guide b Option adapters v Introduction v Description... v Specifications... v References... Ethernet network cabling system b Infrastructure b ConneXium connection components... b ConneXium hub... 0 b ConneXium transceiver b ConneXium switches... Programming software (for M/ME processor adapters) b Concept IEC programming software v Introduction v Functions... v References... b ProWORX for Ladder Logic programming software v Introduction v References... Additional products and services b Optional conformal coating for agressive environments v Introduction v References... 0 b Enhanced grouding system v Introduction v References... 0 b User documentation... 0 b Automation product certifications... 0 b Community regulations b Product reference index... 0 Advantys, Altistart, Altivar, Concept, ConneXium, FactoryCast, FIPIO, FIPway, Lexium, Magelis, M0, Modbus, Modbus Plus, Modicon, Modsoft, Momentum, OSItrack, Phaseo, PowerSuite, Premium, Preventa, ProWORX, Quantum, Schneider Electric, Telefast, TeSys, Transparent Ready, TSX Micro, Twido, TwidoSoft, TwidoSuite, Unity, Unity Pro, Vijeo Designer, Vijeo Look X-Way are trademarks or registered trademarks of Schneider Electric. Other trademarks used herein are the property of their respective owners. 0

8 Introduction A modular concept with four easy pieces The I/O system is comprised of fundamental components that easily snap together in various combinations to form a versatile, distributed I/O system. The four components are: I/O base Communication adapter Processor adapter Option adapter I/O base Communication adapter Option adapter () Processor adapter () Modicon Momentum communication adapters The design of the Modicon Momentum separates the communications from the I/O base, thus creating a truly open I/O system that can be easily adapted to any fieldbus network. When a Modicon Momentum I/O is coupled with a communication adapter, the two form a remote I/O drop that connects directly to virtually any standard fieldbus I/O network. Together, Modicon Momentum I/O supports different types of control systems, including: personal computers, distributed control systems, programmable controllers and Modicon Momentum processors. Modbus Plus communication adapter () The processor adapters are only compatible with Concept or ProWORX software. 0

9 Introduction (continued) I/O bases A specialized Modicon Momentum I/O base supports the rest of the control system. The communication adapter, processor adapter and option adapter all snap onto the I/O base. A selection of I/O base modules are available, including analog I/O, discrete I/O, multi-function analog and bi-directional discrete bases. In addition, Modicon Momentum I/O bases offer simple plug-in terminal strips, as well as standard mm DIN rail or panel mounting, for ease of maintenance and installation. Communication adapter I/O base Modicon Momentum processors adapters and option adapters () When local distributed intelligence is required at the point of control, Modicon Momentum has the answer. The Modicon Momentum M processor adapter is a full fledged PLC containing a CPU, RAM and Flash memory. It is based on the popular Modicon family of PLCs (i.e., directly compatible with Quantum, Compact and PLCs), and snaps onto the Modicon Momentum I/O base, just like the communication adapter. The option adapter provides the processor adapter with additional networking capabilities, a time-of-day clock, and a battery back-up. The option adapter also snaps onto the I/O base. In the figure below,the processor adapter is stacked on top. Option adapter Processor adapter () I/O base Optional conformal coating If your control system needs to operate in a corrosive environment, selected Modicon Momentum modules can be ordered with a conformal coating applied to components of the product. Conformal coating will extend product life and enhance its environmental and performance capabilities. See pages 00 and 0. Enhanced grounding system Due to new In t e rbu s standards for electrical noise immunity, a number of Modicon Momentum products have been updated to include an enhanced grounding system. This system is required to meet the revised electrical noise immunity standard (ability to pass a. kv electrical fast transient burst test). See page 0 for a list of Modicon Momentum products that currently have been updated to include the new grounding system. () The processor adapters are only compatible with the Concept or ProWORX software. 0

10 Selection guide Discrete I/O bases Product type Input modules for direct current Input modules for alternating current Type of signal True high Operating voltage and Input voltage Vdc 0 Vac 0 Vac Current consumption max. 0 ma max. ma Input type IEC Type + IEC Type IEC Type + Output voltage Output type Number of points x In x In x In Potential isolation Point to point None None Group to group None 0 Vac Field to adapter 00 Vac 0 Vac Current capacity Per output Per group Per module Response time OFF-ON. ms 0 0 Hz. 0 Hz ON-OFF. ms 0 Hz. 0 Hz Protection against short circuit and overload Fault reporting Detected output fault Detected I/O error Blown Type of module 0 ADI ADI ADI ADI Pages

11 Output modules for direct current Output modules for alternating current Relay output module True high Vdc 0 Vac 0 Vac 0 to 0 Vdc max. 0 ma max. ma max. ma 0 Vac 0VDC Vdc 0 Vac 0 Vac 0 to 0 Vac to 0 Vdc Solid state switch Triac Relay from C x out x out x out x out x out x out out (isolated) None None 0 Vac for mn None None 0 Vac for mn 00 Vac 0 Vac 0 Vac for mn 0. A 0. A A 0. A A 0. A A A A A A A A A A A A A A A 0 C 0 C < 0. ms max. / x /f 0 ms < 0. ms max. / x /f 0 ms Electronically safeguarded per group LED/Out LED/ Out None to adapter to adapter None LED 0 ADO ADO ADO ADO ADO ADO ADO 0 0 0

12 Selection guide (continued) Discrete I/O bases Product type I/O modules for direct current Type of signal True high True low True high Input voltage Vdc Operating voltage Vdc Current consumption max. 0 ma max. 0 ma + sensor current 0 Input type IEC Type + Output voltage Output type Vdc Solid state switch Number of points x In, x Out x In, x Out Potential isolation Point to point None Group to group None Field to adapter 00 Vac Current capacity Per output 0. A A Per group A A Per module A A Response time OFF-ON. ms In, < ms Out 0 ms in, < ms Out. ms In, < ms Out ON-OFF. ms In, < ms Out 0 ms in, < ms Out. ms In, < ms Out Protection against short circuit and overload Electrically safeguarded outputs Electrically safeguarded outputs and electronically safeguarded sensor supply group Fault reporting Detected output fault LED/Out Detected I/O error to adapter Blown Type of module 0 ADM ADM 0 0 ADM 0 0 ADM 0 0 Pages 0

13 I/O modules for direct current I/O modules for direct and alternating current True high Vdc,, Vdc Vdc 0 Vac Vdc,, Vdc Vdc 0 Vac max. 0 ma 00 Vdc 0 Vdc Vdc max. 0 ma max. 0 ma IEC Type +, monitored IEC Type + IEC Type Vdc,, Vdc 0 Vac or 0 Vdc / Vdc (0 ADM 0 only) Solid state switch Relay (normally open) Triac x In, x Out and x Out 0 Vac x In, x Out x 0 In, x Out x 0 In, x Out None None None 0 Vac None None None None 0 Vac None 00 Vac 0 Vdc 00 Vac 00 Vac 0 Vac 0. A 0. A A ohmic load 0. A A group, A group A ohmic load A A 0 C, 0 C A ohmic load A. ms In, < ms Out. ms In, <. ms Out. ms In, < 0 ms Out max / x /f. ms In, < ms Out. ms In, <. ms Out. ms In, < 0 ms Out max / x /f Electronically safeguarded outputs Electrically safeguarded outputs None Varistor in parallel with each contact internal per group (not against overload) LED/In, LED/Out LED/Out None None to adapter to adapter None None LED/ 0 ADM ADM ADM 0 0 / 0 ADM 0 0 ARM ADM 0 0

14 Introduction, description Discrete I/O bases Introduction products are modular in design. Communication adapters and Processor adapters are designed to work as functional modules when they are snapped onto a Modicon Momentum I/O base. This I/O base requires that some type of Modicon Momentum adapter be attached before it can be functional. I/O bases fit into compact standard housings that can be mounted on a DIN rail or on panels in a cabinet. They read information from field sensing devices and control discrete and analog field actuating devices. Terminal blocks and bus bars are available for use with the bases so that these bases can be used to support -, -, and -wire field devices. I/O field devices and the power supply to the module are connected via three -pin terminal blocks and an optional -, -, or -row busbar. The terminal connectors are electrically connected to the module, while the optional busbars are not. Busbars provide a common connection for the field devices and serve as protective distribution connectors. Depending on the I/O base and the type and number of field devices connected to it, a -, -, or -row busbar may be used. Terminal blocks and busbars are ordered separately, and are not shipped with the Modicon Momentum I/O bases. They are available in either screw-in or spring-clip versions. Description 0 ADp discrete I/O base units feature the following on the front panel: Internal interface connector for the communication module or processor module Locking and ground contact for the communication module or processor module LED status indicators (the number of indicators will depend on the number of channels) Up to three connectors for the removable terminal blocks (Modbus dependent). Grounding screw Slot for the power strip Two screw holes for panel mounting Protective cover Connectors to be ordered separately: b removable screw or spring terminals 0 XTS 00p 00 b to -row screw or spring bus bar 0 XTS 00p 0 0 Specifications: pages to References: page Dimensions, mounting: page 0 Wiring diagrams: pages 0 to

15 Specifications Discrete I/O bases Specifications for discrete input bases Type of input base unit 0 ADI ADI ADI ADI 0 0 Number of inputs x x x Input voltage V DC 0 AC 0 AC Operating voltage V DC AC (@ Hz) AC (@ Hz) Internal current ma 0 (@ Vdc) (@ 0 Vac) (@ 0 Vac) Input voltage range V - 0 DC 0 AC AC ON voltage V + 0 DC AC minimum AC minimum OFF voltage V - + DC 0 AC maximum 0 AC maximum Input current ON ma. minimum 0.0 minimum OFF ma. maximum.0 maximum Input resistance Hz Type of signal True High Response time On-off maximum 0 0 Hz Off-on maximum ms. 0 0 Hz Potential isolation Input to input None None Group to group V None 0 AC Field to communication interface V 00 AC 0 AC Power dissipation W typical, maximum Agency approvals UL, e, CSA, FM Class I, Div. II. typical,. maximum UL, e, CSA UL, e, CSA, FM Class I, Div. II UL, e, CSA 0 References: page Dimensions, mounting: page 0 Wiring diagrams: pages 0 to

16 Specifications (continued) Discrete I/O bases Specifications for discrete output bases Type of output base unit 0 ADO ADO ADO 0 0 Number of outputs x x x Type of output Solid state switch Relay form C Output voltage V DC 0 0 AC, 0 DC Operating voltage V DC 0 0 AC Internal current ma 0 0 Vac Current Point maximum A Group A Module 0 0 C Min. output current ma 0 Leakage current ma Vdc < 0 Vac Surge current A for ms 0 for 0 ms On StateVoltage drop V < A < 0 Vdc Protection (short-circuits, overloads) Outputs electronically protected Via external ma fast-blow Response time On-off maximum ms < 0. 0 Hz Off-on maximum ms < 0. 0 Hz Potential Isolation Output to output V None 0 AC for minute Output group to output group V None 0 AC for minute Field to communication interface V 00 AC 0 AC for minute Power dissipation W. typical. maximum Agency approvals UL, e, CSA, FM Class I, Div. II.0 typical. maximum UL, e, CSA. UL, e, CSA, FM Class I, Div. II Type of output base unit 0 ADO ADO ADO ADO 0 0 Number of outputs x x x x Type of output Triac Output voltage V 0 AC 0 AC Operating voltage V 0 AC (00 for 0 s, 00 for cycle) 0 AC (00 for 0 s, 00 for cycle) Internal current ma Current Point maximum A Group A Module A Min. output current ma 0 0 Leakage current 0 0 Vac Surge current A Point: ( cycle), 0 ( cycles), ( cycles) On StateVoltage drop V <. A <. 0. A <. A <. 0. A 0 Protection (short-circuits, overloads) Via internal A slow-blow per group Response time On-off maximum ms / x /f (= 0, of one line cycle) Off-on maximum ms / x /f (= 0, of one line cycle) Potential Isolation Output to output None Output group to output group None Field to communication interface V 0 AC Power dissipation W.0 typical. maximum Agency approvals UL, e, CSA, FM Class I, Div. II Description: page References: page Dimensions, mounting: page 0 Wiring diagrams: pages 0 to

17 Specifications (continued) Discrete I/O bases Specifications for discrete I/O bases Type of base unit 0 ADM ADM 0 0 ADM 0 0 ADM 0 0 Number of inputs x x Number of outputs x x and x Operating voltage Vdc Internal current ma Vdc Vdc Inputs Voltage Vdc Type of signal True high True low True high Voltage at Vdc Voltage at 0 Vdc Input current ma. min. at state ( ma at c V),. max. at state 0 Input voltage range Vdc Input resistance kw Response time Off to on ms In, < Out On to off ms In, < Out Fault sensing Broken wire detection Outputs Voltage Vdc, 0 max. Type Solid state switch Type of signal True high True low True high Current capacity A 0. per point per group per module 0. per point per group per group per module Leakage current ma Vdc Vdc Peak current A for ms On state voltage drop Vdc < 0. A Detected error indication Output overload for at least one output to communication adapter Output overload for at least one output to communication adapter Response time Off to On ms < 0. On to Off ms < 0. Potential isolation Input to input None Output to output group None Input to output group None Field to communication interface V 00 AC Power dissipation Typical W.0. Maximum W Agency approvals UL, e, CSA UL, e, CSA, FM Class I, Div. II 0 Description: page References: page Dimensions, mounting: page 0 Wiring diagrams: pages 0 to

18 Specifications (continued) Discrete I/O bases Specifications for discrete I/O bases Type of base unit 0 ADM ADM 0 0 Number of points Inputs x x Outputs x x Operating voltage Vdc,, (0 0) Internal current ma Vdc (plus current for sensors) Vdc Vdc Inputs Voltage Vdc,, Type of signal True high Voltage at Vdc Vdc Vdc > Vdc Voltage at 0 Vdc - + Vdc Vdc < Vdc Input current ma. min. at state ( ma at c V),. max. at state Vdc Input voltage range Vdc V Input resistance kw Response time Off to On ms. In, < Out. In, <. Out On to Off ms. In, < Out. In, <. Out Fault sensing Outputs Voltage Vdc, 0 max.,,, 0 max. Type Type of signal Solid state switch True high Current capacity A per point per group per module 0. per point per 0 C per 0 C Leakage current ma Vdc 0 Vdc Peak current A. for ms for ms On state voltage drop Vdc 0. A Detected error indication Output overload for at least one output or short-circuit or overload on one of the encoder supply groups, to communication adapter Response time ms < 0. Off to On, < 0. On to Off Potential isolation Input to input None Output to output group None Input to output group V None 0 DC Field to communication interface Vrms 00 AC 0 DC Output overload for at least one output to communication adapter Power dissipation Typical W..0 + (0. x nb of input points) + (0. x nb of output points) Maximum W 0.0 Agency approvals UL, e, CSA UL, e, CSA, FM Class I, Div. II 0 Description: page References: page Dimensions, mounting: page 0 Wiring diagrams: pages 0 to

19 Specifications (continued) Discrete I/O bases Specifications for discrete I/O bases Type of base unit 0 ADM 0 0 / 0 ADM 0 Number of points Inputs x 0 Outputs x 0 ARM 0 0 Operating voltage V DC 0 AC (... Hz) Internal current ma Vdc minimum load current Inputs Voltage V...0 AC 0... DC Signal type True High On voltage minimum Vdc Off voltage maximum Vdc Input current ma. minimum On,. maximum Off Input voltage range Vdc Input resistance kw Response time ms. Off to On,. On to Off Outputs Voltage V...0 AC, 0... DC / Vdc (0 ADM 0 only) Type Relay normally open Current capacity Vdc A > 0.00 (new contacts), ohmic load A maximum, inductive load A maximum (LR y 0 ms) Current capacity Vdc A Ohmic load 0. A maximum (switching current y. A), inductive load 0. A maximum (LR y 0 ms) Current capacity Vac A A maximum (switching current y. A) cosj =, A maximum cosj = 0. Leakage current ma 0 Vac Detected error indication None Response time ms 0 Hz Off to On, 0 Hz On to Off A per point, A per group, A per module Max. number of switching circuits > 0 x 0 (mechanical), > x 0 (inductive load with external protection circuit) Protection against short circuit and overload None Varistor in parallel with each contact Potential isolation Input to Input None Output group to output Group V rms None 0 AC Input to output group V rms None 0 AC Field to communication interface V rms 00 AC Fusing Internal None External operating voltage ma fast-blow A fast-blow External input voltage max. A fast-blow None External output voltage According to the supply of the connected None actuators not to exceed A slow-blow/group Power dissipation Typical W. Maximum W. Agency approvals UL, e, CSA UL, e, CSA, FM Class I, Div. II 0 Description: page References: page Dimensions, mounting: page 0 Wiring diagrams: pages 0 to

20 Specifications (continued) Discrete I/O bases Specifications for discrete I/O bases Type of base unit 0 ADM 0 Number of points Inputs x 0 Outputs x Operating voltage Vac 0 (... Hz) Internal current ma 0 (@ 0 Vac) Inputs Voltage Vac 0 Signal type True high On voltage minimum Vac Off voltage maximum Vac 0 Input current ma.0 minimum at state,. maximum at state 0 Input voltage range Vac... Input resistance kw Response time ms Maximum / x /f Off to On, maximum / x /f On to Off Outputs Voltage Vac 0 (@ Hz) Type Triac Current capacity 0. A per point maximum, 0 ma per point minimum, A per group, A per module Leakage current ma <. (@ 0 Vac) Signal type True High On state voltage drop Vac <. (@ 0. A) Detected error indication None Response time ms / x /f maximum from state 0 to state, / x /f maximum from state to state 0 Maximum switching cycles Potential Isolation Input to input None Output group to output group None Input to output group None Field to communication interface Vrms 0 AC Power dissipation Typical W Maximum W 000/hr for 0. A inductive load Protection Internal s A x. slow-blow s Agency approvals UL, e, CSA 0 Description: page References: page Dimensions, mounting: page 0 Wiring diagrams: pages 0 to

21 References Discrete I/O bases 0 ADI pp0 p0 0 ADO pp0 p0 0 ADM pp0 pp 0 XTS XTS XTS XTS 00 0 CER 00 0 BSM 0 00 Discrete input bases Type of current Modularity (no. of points) Conformity EC - Reference Weight kg DC V ( x ) Type 0 ADI ( x ) Type 0 ADI AC 0 V ( x ) Type 0 ADI V ( x ) Type 0 ADI Discrete output bases Type of current Output voltage Modularity (no. of points) DC solid state protected DC/AC relay form C AC triac protected, per group Discrete I/O bases Type of output current Input voltage DC solid state Current per output Reference Weight kg V ( x ) 0. A 0 ADO ( x ) 0. A 0 ADO Vdc isolated A 0 ADO Vac 0 V ( x ) A 0 ADO ( x ) 0. A 0 ADO V ( x ) A 0 ADO ( x ) 0. A 0 ADO Vdc Type + Output voltage Vdc protected Modularity Reference Weight Input Outputs, current kg I ( x ) O ( x ) 0. A 0 ADM I, fast ( x ) O ( x ) 0. A 0 ADM I ( x ) O ( x ) 0. A 0 ADM I, wiring O ( x and x 0 ADM check ( x ) ) 0. A I ( x ) O ( x ) A 0 ADM DC relay 0 Vdc 0 Vdc I ( x ) O ( x ) 0. A 0 ADM 0 0 AC or DC relay Vdc Type + AC triac 00 0 Vac Type /0 Vac 0/ Vdc 0 I ( x 0) O ( x ) A 0 ADM 0 0 () ARM 0 () ARM 0 0 () Vac 0 I ( x 0) O ( x ) 0. A protected by 0 ADM Accessories Description Composition Type of connection Reference Weight kg Terminal blocks for I/O base connection Set of connectors row Screw 0 XTS Spring 0 XTS Bus Bar rows Screw 0 XTS 00 0 Spring 0 XTS 00 0 rows Screw 0 XTS 00 0 Spring 0 XTS 00 0 row Screw 0 XTS 00 0 Spring 0 XTS 00 0 Cable grounding rail Used to connect CER 00 the cable shielding High vibration Kit containing sets of clips 0 XTS 0 00 environment clips Dummy base unit Used to prewire the I/O base units 0 BDM Requires screw or spring connection terminals Discrete input simulator channels, Vdc 0 BSM 0 00 Replacement parts Description Use Reference Weight kg Sheets of labels 0 front labels for modules 0 XTS Cable coding For screw or spring connection terminals 0 XCP part kit () Operating voltage Vdc. () Output voltage Vdc. () Operating voltage 0 Vac. 0 Description: page Specifications: pages to Wiring diagrams: pages 0 to

22 Dimensions, mounting, wiring diagrams Discrete I/O bases Dimensions, mounting 0 ADp, rail or panel mounting, () 0, 0 () () holes for M screws, for panel mounting () Equipment or enclosure Wiring diagrams for discrete input bases 0 ADI ADI 0 00 Example of external wiring of, and -wire sensors Example of external wiring of and -wire sensors 0 M L+ ma fast-blow V Return 0 M L+ ma fast-blow V V Return L+ L+L+ A max. fast-blow Option M PE A max. fast-blow Option L+ M M L+ L+ IN + PE -wire sensor IN + -wire sensor -wire sensor IN + IN + M M M M A max. fast-blow -wire sensor -wire sensor Group of channels Group of channels Internal wiring Internal wiring -wire sensor 0 ADI ADI 0 0 Example of external wiring of and -wire sensors Example of external wiring of and -wire sensors 0 V 0 N L 00 ma 0 V slow-blow Return Return 0 N L 00 ma slowblow 0 V Return 0 V Return L L L L NN NN -wire sensor IN + - PE -wire sensor -wire sensor IN + - PE -wire sensor 0 -wire sensor -wire sensor Group of channels Group of channels Internal wiring Internal wiring Description: page Specifications: pages to 0

23 Wiring diagrams (continued) Discrete I/O bases Wiring diagrams for discrete output bases 0 ADO ADO 0 00 Example of external wiring of and -wire actuators Example of external wiring of and -wire actuators Option 0L+ L+ M L+ PE V A max. V fast-blow Return A max. fast-blow ma fast-blow 0 L+L+ Option 0 M L+ M M M PE V ma V fast-blow Return A max. fast-blow A max. fast-blow + Out PE PE PE -wire actuator -wire actuator Out PE -wire actuator + -wire actuator Out PE -wire actuator Group of channels Group of channels Internal wiring Internal wiring 0 ADO 0 0 Example of external wiring 0 M L NO 0/0 VCA L Fast-blow N ma NF 0 Option PE Output Output Output Group of channels Internal wiring 0 Description: page Specifications: pages to References: page Dimensions, mounting: page 0

24 Wiring diagrams (continued) Discrete I/O bases Wiring diagrams for discrete output bases 0 ADO 0 0/ADO ADO 0 0/ADO 0 0 Example of external wiring of and -wire actuator Example of external wiring of and -wire actuators Fuse ( A slow-blow) Fuse ( A slow-blow) Option 0 N L Out - PE -wire actuator L N -wire actuator N L PE 0 V Return 0 V Return Group of channels Group of channels 0 A fast-blo w 00 ma fast-blow Fuse ( A slow-blow) Fuse ( A slow-blow) 0NL Option Out - PE -wire actuator L N -wire actuator N L PE 0 V Return 0 V Return 0 A fast-blow 00 ma fast-blow Internal wiring Internal wiring 0 Description: page Specifications: pages to References: page Dimensions, mounting: page 0

25 Wiring diagrams (continued) Discrete I/O bases Wiring diagrams for discrete I/O bases 0 ADM 0 0/ADM 0 /ADM 0 Example of external wiring of a -wire sensor/actuator 0 M L+ 0 LL+ ma fast-blow A max. fast-blow V V Return Example of external wiring of a -wire actuator with wiring check 0 M L+ 0 LL+ ma fast-blow A max. fast-blow V V Return Option M M L+ A max. fast-blow A max. fast-blow Option M M PE A max. fast-blow I O -wire sensor -wire actuator Out PE -wire actuator Group of channels Group of channels Internal wiring Internal wiring Example of external wiring of a -wire sensor activated by an output 0 M L+ ma fast-blow V V Return Example of external wiring of a -wire sensor/-wire actuator 0 M L+ ma fast-blow V V Return 0 LL+ A max. fast-blow Option 0 LL+ A max. fast-blow Option M M PE A max. fast-blow Option M M L+ M A max. fast-blow A max. fast-blow IN + PE PE -wire sensor -wire sensor IN + PE -wire actuator -wire sensor Group of channels Group of channels Internal wiring Internal wiring 0 Description: page Specifications: pages to References: page Dimensions, mounting: page 0

26 Wiring diagrams (continued) Discrete I/O bases Wiring diagrams for discrete I/O bases 0 ADM ADM 0 0 Example of external wiring of -wire sensor/actuator Example of external wiring of and -wire sensors/-wire actuator 0 M L+ 00 ma fast-blow V V Return 0 M L+ A max. fast-blow V V Return Option I L+ L+ k M M L+ A max. fast-blow A max. fast-blow A max. fast-blow 0 L+ Option L+ L+ L+ L+L+ M M M PE A max. slow-blow A max. slow-blow k (connected directly to sensor) O -wire actuator IN + PE -wire sensor + -wire actuator -wire sensor Group of channels Group of channels Internal wiring Internal wiring 0 ADM 0 0 (continued) Example of external wiring of -wire actuator with wiring check Special external wiring, the output activates the sensor 0 M L+ A max. 0 L+ L+ slow-blow V A max. V fast-blow Return 0 M L+ 0 L+L+ A max. fast-blow A max. slow-blow V V Return L+ Option L+ L+ L+ M M PE M A max. slow-blow L+ Option L+ L+ L+ M M PE M A max. slow-blow Out PE -wire actuator IN + PE -wire sensor Group of channels Group of channels Internal wiring Internal wiring 0 Description: page Specifications: pages to References: page Dimensions, mounting: page 0

27 Wiring diagrams (continued) Discrete I/O bases Wiring diagrams for discrete I/O bases 0 ADM ADM 0 0 / 0 ADM 0 Example of external wiring of: v -wire sensor v -wire actuator v -wire actuator with wiring check v -wire sensor actived by output Example of external wiring of or sensor/-wire/actuator I I0 I 0 M-L+ O O0 O () 0 0 V 0 0 V Return 0 L+ M M L+M L+ ma fast-blow V Return L N 0 M-L+ max. 0 A () P M 0M P M-L+ ma () max. A () Option IN L - PE () L+ 0 L+L M N N L - PE () N N PE A max. fast-blow A max. slow-blow A max. slow-blow In + -wire sensor PE + -wire actuator In PE -wire actuator Sensor actived by output -wire sensor Group of channels Group of channels -wire actuator Internal wiring Internal wiring () Fast-blow : c V: 0 ma, c V: ma, c V: 00 ma. () Fast-blow. () For -wire sensor () For -wire actuator 0 ARM ADM 0 Example of external wiring of -wire sensor/-wire actuator Example of external wiring of -wire sensor/ and -wire actuators N L L+ M PE L+L N PE N N PE a 0 V A max. fast-blow Return A max. slow-blow N Fuse (, A slow-blow) 0 NC N N N Fuse a V (, A slow-blow) Return a 0 V N N L N N L L ma fast-blow A max. slow-blow A max. N fast-blow PE Return a V Return IN + PE IN PE -wire sensor L N PE IN Out N PE L N -wire sensor -wire actuator -wire sensor -wire actuator -wire actuator Group of channels Group of channels Internal wiring Internal wiring 0 Description: page Specifications: pages to References: page Dimensions, mounting: page 0

28 Selection guide Analog I/O bases Applications Vdc analog input bases Operating voltage Vdc Measurement range Inputs ± V, ± 0 V, ± 0 ma - V, -0 ma Inputs ± V, ± 0 V, -0 ma Inputs ± mv, ± 00 mv, Temperature probe Pt 00, Pt 000, Ni 00, Ni 000 Thermocouple B, E, J, K, N, R, S, T Modularity Input channels differential inputs single-ended inputs differential inputs Output channels Discrete I/O Resolution bits + sign bipolar bits unipolar bits + sign bits + sign Update time. +. x no. of declared channels (ms) +. x no. of declared channels (ms 00 ms Potential isolation Between channels 00 Vdc, min None 00 Vdc Base and ground 00 Vdc, min 00 Vdc, min 00 Vdc, min Channels and ground 00 Vac, min 0 Vac, min 00 Vac Protection Polarity inversion Number in words In words in words in words in Out words out words out words out Fail states Type of communicating module 0 AAI AAI AAI 0 0 Pages 0

29 Vdc analog output bases Vdc mixed I/O bases (analog/discrete) Vdc Vdc Vdc Outputs ± 0 V, 0-0 ma Outputs ± 0 V, -0 ma Inputs ± V, ± 0 V, ± 0 ma - V, -0 ma Outputs ± 0 V, 0-0 ma Inputs 0 0 V Outputs 0 0 V Inputs V Outputs V differential inputs inputs with common point outputs outputs outputs with common point inputs Vdc outputs Vdc/0. A inputs Vdc outputs Vdc/ A inputs Vdc outputs Vdc/0. A bits + sign Inputs: bits (dep. on range) Outputs: bits Inputs: bits Outputs: bits ms Inputs: 0 ms Outputs: ms None None 00 Vdc, min 00 Vac, min 00 Vac, min 00 Vac, min Polarity inversion Short-circuits and overloads (for discrete outputs) Inputs: 0. ms (for inputs) Outputs:. ms (for inputs) words in words in words in words out words out words out words out Hold, reset to zero, reset to full scale Hold or reset to zero 0 AAO AAO 00 0 AMM AMM ANR ANR 0 0

30 Introduction, description Analog I/O bases Introduction analog input bases enable acquisition of various analog values encountered in industrial applications, including: b Standard high level (± V, ±0 V, - V, -0 ma, ± 0 ma) b Low level (± mv, ± 00 mv) b Thermocouples (B, E, J,...) b Temperature probes (Ni..., Pt...) Analog output bases are used to control analog field devices such as: speed drives and proportional control valves. The current or the voltage is proportional to the digital value defined by the user program. The outputs can be configured so that when the program stops, the outputs either reset to zero or hold the last value received. This feature is useful during debugging because, if the outputs are set to Hold, the operation of the analog field devices is not disturbed every time the program stops. Designed to cover a wide range of applications, Modicon Momentum I/O bases offer the following functions in addition to A/D or D/A conversion: b Choice of input/output ranges (voltage, current, thermocouple, temperature probes) b Selection of number of channels used b Cold junction compensation for thermocouple modules b Broken wire detection (0 AAI 00 00, 0 AAI 0 00 and 0 AAI 0 0 models) Description 0 App analog I/O base units feature the following on the front panel: Internal interface connector for the communication module or processor module Locking and ground contact for the communication module or processor module LED status indicators (the number of indicators will depend on the number of channels) Two connectors for the removable terminal blocks Grounding screw Slot for the power strip Two screw holes for panel mounting Protective cover Connectors to be ordered separately: b removable screw or spring terminal blocks 0 XTS 00p 00 b to -row screw or spring bus bar 0 XTS 00p 0 0

31 Specifications Analog I/O bases Specifications for analog input bases Type of base units 0 AAI Number of inputs x differential imputs LEDs Format of data Ready (green) Full bits signed ( s complement) Protection Base and actuators Polarity inversion Ranges ± 0 Vdc ± Vdc 0 ma ± 0 ma Vdc Input impedance kw >.000 > >.000 Maximum variation at C % Maximum variation at 0 C % Resolution bits + sign bipolar bits unipolar Conversion times ms ms max. for input channels (. ms per input channel +. ms) Error indication None Isolation Channel to channel Vdc ± 00 for minute Field to ground Vdc 00 for minute Communication adapter to Vac 00 for minute ground Common mode rejection Channel to ground 0 Hz or 00 Vdc Crosstalk between channels db u 0 External power requirement Nominal Vdc Limit values Vdc 0. to. Current ma Vdc EMC for industrial environment Immunity IEC surge on auxiliary power supply kv Emissions EN 00- Approvals UL, CSA, e 0 References : pages and Dimensions : page Wiring diagrams : pages and

32 Specifications (continued) Analog I/O bases Specifications for analog input bases Type of base units 0 AAI AAI 0 0 Number of inputs x single-ended input x differential inputs Format of data Full bits signed ( s complement) Protection Base and actuators Polarity inversion Error indication Ranges ± 0 V ± V 0 ma ± mv ± 00 mv Input impedance kw > 00 > 00 < 0.0 > 0000 > 0000 Maximum variation at C 0. % FS 0. % FS 0. % FS ± µv ± µv Maximum variation at 0 C 0. % FS 0. % FS 0. % FS ± µv ± µv Temperature drift (0 C) 0 PE / C 0 PE / C 0 PE / C PE (Full scale) 0 V V ma Resolution bits + sign bits + sign bits bits + sign Filtering Low pass with cut-off frequency 0 khz Current source Pt00 ma 0. Ni00 ma 0. Pt000 ma 0. Ni000 ma 0. Update time ms +. x n n = number of declared channels Error indication None Potential isolation Channel to channel Vdc None 00 Base power supply and ground Vdc 00 for minute 00 for minute Channels to ground Vac 0 for minute 00 for minute Base power V ± 0 (voltage or current output) ± 0 (voltage or current output) Common mode Channel to ground V ± 00 DC, 0 AC Common mode Voltage between channels None V 00 DC, AC single phase or -phase or 0 AC single phase Common mode rejection Channel to ground 0 Vac at Hz or 00 Vdc db DC, db AC 0 Hz, db AC 0 Hz Between channels 0 db DC, 0 db AC 0 Hz, 0 db AC 0 Hz Serial mode rejection db AC 0 Hz, db AC 0 Hz 00 Input protection Polarity inversion Operating voltage Vdc Internal current ma Vdc Power dissipation Typical W.. Maximum W.. Fusing Internal A slow-blow A slow-blow External 00 ma fast-blow 00 ma fast-blow Agency approvals UL, e, CSA, FM Class I, Div. II 0 References : pages and 0 Dimensions : page Wiring diagrams : pages and

33 Specifications (continued) Analog I/O bases Specifications for analog output bases Type of base units 0 AAO AAO 00 Number of outputs x Format of data Full bits signed ( s complement) Protection Base and actuators Polarity inversion Ranges ± 0 V 0 0 ma ± 0 V 0 ma Load impedance kw minimum 0. maximum minimum 0. maximum Capacitive load µf < Maximum variation at C % 0. PE 0. PE 0. PE 0. PE Maximum variation at 0 C % 0. PE 0. PE 0. PE 0. PE Temperature drift (0 C) 0 PE / C 0 PE / C 0 PE / C 0 PE / C Resolution bits + sign Update time ms < Full scale Fail State 0 V in the range of ± 0V ma in the range of 0 0 ma Hold, reset to zero, reset to full scale Potential isolation Channel to channel None Base power supply and ground Vdc 00 for minute Channels to ground Vac 00 for minute Outprotections Short-circuits in the voltage circuits, open in current polarity inversion Base power V ± 0 (voltage or current output) Common mode rejection Vac Hz or 0 DC channel to ground Operating voltage Vdc Internal current Base ma Vdc Actuators ma Vdc Power dissipation Typical W. Maximum W. Internal fusing A, slow-blow Agency approvals UL, e, CSA 0 References : pages and Dimensions : page Wiring diagrams : pages and

34 Specifications (continued) Analog I/O bases Specifications for discrete and analog I/O bases Type of base unit 0 AMM AMM 00 0 Number of inputs and outputs x differential inputs x discrete inputs x analog outputs x discrete outputs Operating voltage Vdc Internal current ma 00 typical (at Vdc), 0 maximum (at Vdc) Differential inputs for 0 AMM 00 00/ maximum (at Vdc) Conversion time 0 ms for all channels Conversion tolerance ± 0 V ± V V ± 0 ma 0 ma C % C % Resolution bits bits bits bits bits Conversion consistency % ± 0.0 ± 0.0 ± 0.0 ± 0.0 ± 0.0 Common mode voltage Input voltage starting at Ag ± V Common mode suppression db > 0 Overvoltage Voltage ranges V ± 0 solid state if voltage is V ± 0 dynamic max. 00 ms ± 0 solid state if voltage is V ± 0 dynamic max. 00 ms Overvoltage current ranges ma > Input resistance W M 0 Fail state Hold or reset to zero Discrete inputs Voltage Vdc typical, 0 maximum typical Signal Type True high On Voltage Vdc Off Voltage Vdc Input current ma. minimum at state ( ma at operating voltage),. maximum at state 0 Input resistance kw. Response time ms. from 0 to state. from to state 0 Analog outputs Resolution bits for single-phase measuring range 0 0 ma, bits for -phase measuring range ± 0 V Conversion time ms for all channels Conversion maximum variation C max. ± 0. % of upper measuring range value 0 C max. ± 0.0 % of upper measuring range value Output load u kw for voltage output, y 00 W for current output Discrete outputs Voltage Vdc typical, 0 maximum Type Semiconductor Signal Type True high Current capacity per channel, per group, per module Leakage current ma Vdc Vdc On State Voltage drop Vdc < A < 0. A Response time Off to On ms < 0. On to Off ms < 0. Output protection The outputs are protected against overload and short-circuit-circuiting Output indicator red LED per On output in the event of an overload or short-circuit-circuiting Error message Message I/O error on bus adapter if module is defective Max. Switching cycles 000/hr (inductive load A), 00/s (resistive load A), /s (filament load. W) Potential isolation Discrete input and output None Analog input to output None Analog input and output and to Vac 00 for minute operating voltage Operating voltage and inputs and outputs from ground Vac 00 for minute Power dissipation Typical W.0 Maximum W.0 0 Agency approvals UL, e, CSA, FM Class I, Div. II UL, e, CSA References : pages and Dimensions : page Wiring diagrams : pages and

35 Specifications (continued) Analog I/O bases Specifications for discrete and analog I/O bases Type of base unit 0 ANR ANR 0 Number of inputs and outputs x analog inputs x discrete inputs x analog outputs x discrete outputs Operating voltage Vdc, range...0 Internal current ma Vdc Analog inputs Resolution bit Input range Vdc Input type Single-ended Conversion time 0. ms maximum for input channels Conversion tolerance 0. C for 0-0 Vdc inputs Max input signal Vdc for voltage input Max temperature drift Vdc 0 inputs Input resistance MW > for voltage inputs Discrete inputs Voltage Vdc Configuration groups of inputs Signal Type True high Minimum on voltage Vdc > Maximum off voltage Vdc < Input current Minimum On ma Maximum Off ma Input voltage Range Vdc Surge Vdc peak for 0 ms Response time Off to On ms., On to Off ms. Analog outputs Resolution bit Output range Vdc Conversion time ms.0 for four channels Conversion tolerance max % of upper measuring range C Output load > kw Vdc Fail state Hold or reset to zero Discrete outputs Voltage Vdc 0-0 operating, 0 for ms maximum Type Solid State Switch Signal type True high Current capacity A 0. per point, per group, per module Leakage current ma 0 Vdc Surge current A. for ms On state voltage drop Vdc < 0. A current Response time Off to On ms. On to Off ms.0 Output protection The Outputs are protected against overload and short-circuiting Output indicator LED per point Potential isolation Discrete input to output None Analog input to output None Analog input and output to Vac 00 for minute. operating voltage Operating voltage and inputs and outputs from ground Vac 00 for minute Power dissipation Typical W.0 Maximum W.0 Agency approvals UL, e, CSA 0 References : pages and Dimensions : page Wiring diagrams : pages and

36 References Analog I/O bases 0 AAI pp0 p0 0 AAO pp 00 Analog input bases Type of inputs Number of channels Ranges Reference Weight kg bits + sign single-ended ± V, ± 0 V, -0 ma 0 AAI bits + sign, differential Pt 00, Pt 000, NI 00 thermocouples B, E, J, K, N, R, S, T, differential ± V, ± 0 V, -V ± 0 ma, -0 ma Analog output bases Type of outputs Number of channels 0 AAI AAI Ranges Reference Weight kg bits + sign ± 0 V, 0-0 ma 0 AAO ± 0 V, -0 ma 0 AAO Discrete and analog I/O bases Type Ranges Reference Weight kg Inputs Outputs Inputs Outputs differential analog analogs bits + sign bits discretes discretes 0. A ± V, ± 0 V - V ± 0 ma -0 ma 0-0 ma ± 0 V Vdc Vdc 0 AMM AAM differential analog analogs bits + sign bits ± V, ± 0 V - V ± 0 ma -0 ma 0-0 ma ± 0 V 0 AMM discretes discretes 0. A Vdc Vdc analog bits analogs bits x discretes x discretes 0. A analog bits analogs bits x discretes x discretes 0. A 0-0 V 0-0 V 0 ANR Vdc Vdc ± 0 V ± 0 V 0 ANR Vdc Vdc 0 Specifications : pages to Dimensions : page Wiring diagrams : pages and

37 References (continued), dimensions, mounting Analog I/O bases 0 XTS XTS XTS 00 0 Accessories Description Composition Type of connection Terminal blocks Set of connectors row Reference Weight kg Screw 0 XTS Spring 0 XTS Bus Bar rows Screw 0 XTS 00 0 Spring 0 XTS 00 0 rows Screw 0 XTS 00 0 Spring 0 XTS 00 0 rows Screw 0 XTS 00 0 Spring 0 XTS XTS XTS 00 0 Cable Grounding Rail High vibration environment clips Used to connect the cable shielding CER 00 Used to prewire the I/O base units. Requires screw or spring connection terminals 0 BDM XTS 00 0 CER 00 Replacement parts Description Use Reference Weight kg Sheets of labels Set of codingand locating device Dimensions, mounting 0 App Rail or panel mounting 0 front labels for 0 XTS modules For screw or spring connection terminals 0 XCP (), () 0, 0 () holes for M screws, for panel mounting. () Equipment or enclosure. 0 Specifications : pages to Wiring diagrams : pages and

38 Wiring diagrams Analog I/O bases Wiring diagrams for analog input bases and analog output bases 0 AAI AAI 0 00 Example of external wiring of -wire sensor Example of external wiring of -wire sensor Inl+ Inl+ Inl+ Inl+ Inl+ Inl+ Inl+ Inl+ Inl+ Inl0+ Inl+ Inl+ Inl+ Inl+ Inl+ Inl+ V InU InU InU InU InU InU InU InU M- L+ 0 InI InI InI InI InI InI InI InI + Vdc Return AGND M L + 00 ma fast-blow Return Agnd Agnd Agnd Agnd Agnd Agnd Agnd Agnd 0 InI InI InI InI InI InI InI InI InU+ InU+ InU+ InU+ InU+ InU+ InU+ InU+ InU+ InU0+ InU+ InU+ InU+ InU+ InU+ InU+ + U + I U + Vdc + I + + Voltage input Current input Group of channels Internal wiring 0 AAI AAO 0/ 00 Example of external wiring of sensor Example of external wiring of -wire actuator IS+ RTD+ RTD IS IS+ RTD+ RTD IS IS+ RTD+ RTD IS IS+ RTD+ RTD IS InU+ InU InU+ InU InU+ InU InU+ InU M L+ M L+ V Return 00 ma fast-blow Fuse ( A slow-blow) OutI L+ OutI+ M OutU+ M L+ M M OutI OutI+ OutU+ Fuse ( A slow-blow) L+ M M OutI OutI+ OutU+ L+ M M OutI OutI+ OutU+ M- L+ M- L+ 0 ma fast-blow 0 ma fast-blow V Return + U + U + U Group of channels Group of channels Internal wiring Internal wiring 0

39 Wiring diagrams (continued) Analog I/O bases Wiring diagrams for discrete and analog bases 0 AMM 00 00/AMM 00 0 Example of external wiring of -wire sensor Example of external wiring of -wire actuator U+ IS U+ IS U+ IS U+ IS QV QI QV QI I I I I M L+ () ma () fast- Return blow U+ IS U+ IS U+ IS U+ IS QV QI QV QI I I I I M L+ () ma () fast- Return blow UI I+ + I UI I+ UI I+ UI + U External bridge I+ AGND AGND AGND AGND O O M M M L+ A fastblow UI I+ UI I+ UI I+ UI I+ AGND + I -wire actuator AGND AGND AGND O O M M + U -wire actuator M L+ A fastblow Group of channels Group of channels Internal wiring Internal wiring 0 AMM 00 00/AMM 00 0 (continued) 0 ANR 0 0/ Example of external wiring of digital sensor/actuator Example of mixed discrete and analog I/O sensor/actuator field wiring U+ IS U+ IS U+ IS U+ IS QV QI QV QI I I I I M L+ ma fastblow () () Return I I I I I I I I AI AI AI AI AI AI M- L+ 0 DGnd AGnd + Vdc Fuse () - Return UI I+ UI I+ UI I+ UI I+ AGND AGND AGND AGND O O M M M L+ A fastblow A0 A0 A0 A0 M- L+ 0 + Vdc Fuse () - Return L+ M M PE A fastblow + + Discrete output Nr. Analog input Nr. Analog output Nr. - Return Discrete input Nr. + Vdc Fuse () IN + PE Out PE Group of channels -wire sensor -wire actuator Internal wiring () c V for 0 AMM 00 00, c V for 0 AMM () Depending on application, max A. 0

40 Selection guide Specialty module I/O bases Product type High-speed counter Operating voltage Vdc Unique features independent, high-speed (0 khz-00 khz) counters Modularity Input channels ( per counter) True High Inputs Output channels ( per counter) True High Outputs Input specifications Counter inputs Vdc differential input, 00 khz counter; Vdc single-end input, 0 khz counter Discrete inputs ( x ) Vdc inputs: - voltage range, - to + 0 Vdc - response time, ms Off to On or On to Off Output specifications Counter outputs Two Vdc differential outputs min 0 Vdc Discrete outputs ( per counter) Vdc outputs: - on current, 0. A per point, A per counter - response time: < 0. ms Off to On, < 0. ms On to Off Protection Surge Input voltage V peak for 0 ms Output current A for ms Type of module 0 AEC 0 00 Pages 0

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

Optimize your simple machines... Modicon M218 Selection Guide

Optimize your simple machines... Modicon M218 Selection Guide Optimize your simple machines... Modicon M218 Selection Guide Compact Solution for Simple Machines Optimized Logic Controller Modicon M218 With intelligent software platform, specialized functional s,

More information

40.3. Control Relays and Timers

40.3. Control Relays and Timers .3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

Power Supplies 3. SDN-P DIN Rail Series

Power Supplies 3. SDN-P DIN Rail Series SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

Square D Model 6 Motor Control Centers

Square D Model 6 Motor Control Centers Square D Model 6 Motor Control Centers with Ethernet Communications What is industrial Ethernet? Over the past few years the use of Ethernet communications has spread into every corner of the business

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

Number 1 in efficiency

Number 1 in efficiency PowerXL DE1 Variable Speed Starter www.eaton.eu/de1 Number 1 in efficiency The easiest way of variable motor speed NEW Variation DE11 The new device category! The PowerXL DE1 Variable Speed Starter Why

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC

CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules

More information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V

More information

MINI MCR-SL-R-UI(-SP)

MINI MCR-SL-R-UI(-SP) Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

Permissible ambient temperature Operation Storage, transport

Permissible ambient temperature Operation Storage, transport The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems

More information

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE Technical Teaching Equipment Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE EDIBON SCADA System Teaching Technique used 4 5 2 Data Acquisition Board Cables and

More information

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting Series - Relay interface modules 8-10 - 16 A Features.01.02 1 & 2 pole relay interface modules, screw terminal socket, mm wide. Ideal interface for PL and electronic systems.01-1 Pole 16 A.02-2 Pole 8

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

Allen-Bradley/Rockwell

Allen-Bradley/Rockwell MANUFACTURER DATA SHEET High Speed Counter Manufacturer: Allen-radley/Rockwell Model Number: 1746-HSCE See www.geomartin.com for additional PDF datasheets Martin Part Number: E-014901-03 VendorPartNumber:

More information

MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!

MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise! Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount

More information

NETWORK ENABLED EQUIPMENT MONITOR

NETWORK ENABLED EQUIPMENT MONITOR NETWORK ENABLED EQUIPMENT MONITOR Remotely Monitor Sensors over the Internet Connect Sensors to the Web to Remotely Monitor Equipment, Processes or Other Applications A Complete, Easy to Deploy, Stand-Alone

More information

Analog signal converters CC-E I/I Current / current isolators

Analog signal converters CC-E I/I Current / current isolators ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between

More information

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.

More information

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component. Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on

More information

www.curtisinstruments.com

www.curtisinstruments.com CANBUS I/O EXPANSION MODULE MODELS 56 / 56P FEATURES Eighteen multi-purpose I/O pins provide simple, flexible vehicle control system expansion. Two high-frequency (A, A) PWM driver outputs support a variety

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01 ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions

More information

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.

More information

SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved.

SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved. SIMATIC S7-1200 It s the Interplay that makes the difference SIMATIC S7-1200 Controller SIMATIC S7-1200 CPUs CPU 1211C 3 configurations per CPU Dimensions W x H x D (mm) CPU 1212C CPU 1214C DC/DC/DC, AC/DC/RLY,

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

is then retained absolutely without interruption.

is then retained absolutely without interruption. Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection

More information

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO GSM-PRO GSM-PRO perfect for communication CONTA-CLIP s GSM-PRO module offers a remote control and maintenance solution which allows you to monitor and control decentralized facilities. The GSM-PRO module

More information

80 Series - Modular timers 16 A. Features 80.01 80.11

80 Series - Modular timers 16 A. Features 80.01 80.11 80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h

More information

Preset Counter signo 721

Preset Counter signo 721 Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage

More information

Automation Unit TM 1703 ACP Flexible automation and telecontrol

Automation Unit TM 1703 ACP Flexible automation and telecontrol Automation Unit Flexible automation and telecontrol Power Transmission and Distribution Outstanding performance: Automate simply with Highly complex and yet fully transparent automation solutions are not

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

Machines Installations with industrial communications Select the winning network

Machines Installations with industrial communications Select the winning network AUTOMATION AND CONTROL Dernière MAJ : 24/11/06 Machines and Installations page Couv 1 CS460-EN_Ver1.0 Couverture 1 st & 4 th 2 Quadri Chapitre 0 3 G0008-EN_Ver1.1 Simply Smart 1 1 1 Quadri G0020-EN_Ver1.1

More information

Programming Logic controllers

Programming Logic controllers Programming Logic controllers Programmable Logic Controller (PLC) is a microprocessor based system that uses programmable memory to store instructions and implement functions such as logic, sequencing,

More information

Solid State Timers Type F

Solid State Timers Type F Solid State Timers Type F Class 9050 CATALOG CONTENTS Description.....................................................Page Product Descriptions............................................. 3 Application

More information

S-series SQ Controller

S-series SQ Controller DeltaV Distributed Control System Product Data Sheet December 2015 S-series SQ Controller Scalable controllers Quick assembly Easy-to-use Field proven architecture Designed for Electonic Marshalling Advanced

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

CQM1-SF200/CS1W-SF200

CQM1-SF200/CS1W-SF200 Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit

More information

CompactLogix Power Supplies Specifications

CompactLogix Power Supplies Specifications Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,

More information

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals. Accepts inputs of between 20 mv to 550 V rms to give

More information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data. 425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and

More information

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Safety Relays ESM/ESM-F

Safety Relays ESM/ESM-F Safety Relays ESM/ESM-F More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in

More information

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51 34 Series - Slim electromechanical PCB relays 6 34 SERIES Features 34.51 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in

More information

Multi-Range Programmable DC Power Supplies 9115 Series

Multi-Range Programmable DC Power Supplies 9115 Series Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional

More information

Ordering Part Numbers: Universal Signal Converter: USC-CVB225-01 Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

Ordering Part Numbers: Universal Signal Converter: USC-CVB225-01 Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V Description: The universal signal converter offers threeway isolation and translates one input control signal into one to three simultaneous outputs. Switches allow the user to select the desired input

More information

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)

More information

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry

More information

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000. NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

Specifications for EM223 24 VDC 4 In/4 Out and EM223 24 VDC 4 In/4 Relay Out

Specifications for EM223 24 VDC 4 In/4 Out and EM223 24 VDC 4 In/4 Relay Out SIMATIC S7-200 EM223 Digital Combination Modules EM223 2 VDC In/ Out and EM223 2 VDC In/ Relay Out Table 1 Specifications for EM223 2 VDC In/ Out and EM223 2 VDC In/ Relay Out EM223 2VDC In/Out 6ES7 2231BF200XA0

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog APC DIN Rail Control Panel Mounting Uninterruptible Power Supply Catalog 2014 Contents Introduction, description... 4 Specifications...5 References....6 Dimensions...7 Wiring diagrams....8 Product reference

More information

Multifunction devices

Multifunction devices devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2

More information

THE INPUT/OUTPUT SYSTEM. Key Points

THE INPUT/OUTPUT SYSTEM. Key Points M O D U L E T W O THE 2 INPUT/OUTPUT SYSTEM Key Points In the first module, you learned about the basic architecture and operation of the Allen-Bradley Micrologix 1000, including a brief introduction to

More information

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Panel Meters and Controllers Modular Panel Meter Type EDM 35 Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

Charge Controller CC611/CC612 Preliminary datasheet

Charge Controller CC611/CC612 Preliminary datasheet Preliminary datasheet Preliminary datasheet CC61x_D00xxx_00_D_XXE_preliminary/04.2015 Product description The ender charge controller CC611 is the main component of a charging point and is designed for

More information

7 - Phaseo power supplies and transformers

7 - Phaseo power supplies and transformers /0 Contents 0 - Phaseo power supplies and transformers Selection guide: Phaseo power supplies Modular, Optimum and universal ranges........................ page /2 Selection guide: Phaseo power supplies

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information