Laboratory water purification systems

Size: px
Start display at page:

Download "Laboratory water purification systems"

Transcription

1 Laboratory water purification systems

2 Choosing a water purification system Application ISO 3696 classification Suggested model and configuration Page Feed water for labware washers Sterifeed 20 Feed water for autoclaves Grade 3 Crystal 7 RO 18 Glassware rinsing RO 15 Feed water for automated biochemistry analyzers General laboratory work Electrochemistry Flame AAS Wet chemistry Spectrophotometry Buffer and media preparation Reagent preparation Ion chromatography ICP-MS Grade 2 Crystal Clinic 22 Grade 2 Grade 1 Crystal 7 Pure 18 Pure 15 Crystal B Pure 10 Trace 12 Graphite AAS ICP-OES Crystal B Trace 3 12 Gas chromatography Grade 1 Crystal B 3 Integrity 6 TOC measurements Onsite 8 cytometry Bio 12 Cell and tissue culture Grade 1 Crystal B Bio 3 Integrity Bio 6 Molecular biology Onsite Bio 8 2

3 systems Crystal B series Crystal B ultrapure systems are multi-purpose water purification systems. The Crystal B systems produce ultrapure and pure water directly from tap water. Crystal B Ultrapure systems are available in the following configurations: Crystal B Trace (P/N CB-1015) produces water for inorganic trace analysis. Water can be used for atomic absorption spectrometry (with graphite furnace atomizer), ICP-OES analysis, ICP-MS and other inorganic analytical methods. Crystal B (P/N CB-1101) produces water with very low organic carbon (TOC) content meeting requirements of liquid chromatography methods. Crystal B water can also be used for some microbiological and molecular biology appli cations. Crystal B Bio (P/N CB-1201) system produces water with very low organic and RNase/DNase content that is intended for the use in molecular biology, including RNase-sensitive applications. Any configuration of a Crystal B ultrapure system produces both ultrapure and pure water. Ultrapure (Grade 1) water is d through the point-of-use on the front panel. Pure (Grade 2) water is d directly from the storage. Crystal B ultrapure water can be used for the most demanding appli cations including, but not limited to: inorganic trace analysis liquid chromatography cell culture molecular biology With resistivity of 18.2 Mega- Ohm*cm (0.055 μs/cm) ultrapure water produced by a Crystal B system exceeds requirements of all relevant standards (ISO 3696 Grade 1, ASTM Type I, CLSI Type I). Purified water is collected in a storage. An integrated recirculation system ensures consistent of water and reduces total organic carbon (TOC) to very low levels: <2ppb for and Bio configurations and 5-10 ppb for the Trace configuration. produced by the Crystal B systems complies with the requirements of ISO 3696 Grade 2 water and can be used for labware washing, wet chemistry methods, flame spectrophotometers, etc. The rate of ultrapure water is 2 L/min. Whereas the rate of pure water is 4 L/min. All Crystal B systems have a controller with a graphic LCD display for water indication. The LCD display provides all necessary information about system status, as well as the remaining life and deionization (DI) performance. The smart DI monitoring system also provides a reduction in running costs. A user is instructed to replace the DI only when the is near the end of its service life. If a Bluetooth option (P/N 10103) is installed, the controller can be detached, so the Crystal B system can be controlled remotely. If spacesaving is crucial, wall-mounting the Crystal B, and the use of a remote control is the right choice. All cartridges and s are easily accessible and no tools are required to replace them. The Crystal B system can be installed on a laboratory bench or mounted on a wall. The Crystal B has important safety functions: filling control tap water pressure control protection from failure The Crystal B systems include: Pre- set Deionization Final stage polishing 25L storage with an integrated Grade II dispensing system Point-of-use final (0.22 μm micro for the Crystal B Trace and systems) Ultra for the Crystal B Bio systems; and/or a photo-oxidation for elimination of organics ( and Bio configurations) UV sterilization (Bio configuration) 3

4 diagrams (RO ) Deionization Shunting Final point of-use Check Polishing Protective Ultrapure water Pure (Grade 2) water Crystal B Trace (RO ) Deionization Shunting Polishing Final point of-use Check Protective Dual wavelength UV photooxidation (185/254 nm) Ultrapure water Pure (Grade 2) water Crystal B (RO ) Check Deionization UV sterilization (254 nm) Shunting Polishing Final point of-use Protective Dual wavelength UV photooxidation (185/254 nm) Ultrapure water Pure (Grade 2) water Crystal B Bio 4

5 Applications Application Crystal B Trace Crystal B Crystal B Bio Reagent preparation Ion chromatography ICP-MS Atomic absorption spectrophotometry with graphite atomizer ICP-OES Gas chromatography Total Organic Carbon measurement cytometry Cell and tissue culture Molecular biology Components Accessory Pre- set for chlorine and organics reduction Crystal B Trace Crystal B Crystal B Bio Deionization, standard Polishing Photo-oxidation Point-of-use micro Point-of-use ultrafiltration UV sterilization Integrated TOC monitor option Removable controller with Bluetooth option option option Specifications Purified water specifications Crystal B Trace Crystal B Crystal B Bio Pure (Grade 2) water resistivity >10 MΩ x cm >10 MΩ x cm >10 MΩ x cm Pure (Grade 2) water conductivity <0.1 μs/cm <0.1 μs/cm <0.1 μs/cm Ultrapure (Grade 1) water resistivity 18.2 MΩ x cm 18.2 MΩ x cm 18.2 MΩ x cm Ultrapure (Grade 1) water conductivity μs/cm μs/cm μs/cm TOC 5 10 ppb <2 ppb <2 ppb RNase <0.01 ng/ml DNase <4 pg/μl Bacteria < 1 cfu/ml < 1 cfu/ml < 1 cfu/ml Endotoxins <0.15 EU/mL <0.15 EU/mL < EU/mL icles > 0.22 μm <1/ per ml <1/ per ml <1/ per ml Nominal flow, pure water (to storage ) 10 L/h 10 L/h 10 L/h Nominal flow, ultrapure water 2 L/min 2 L/min 2 L/min Nominal flow, pure water 4 L/min 4 L/min 4 L/min Deionization life (standard ) 1 m 3 1 m 3 1 m 3 Recovery >30 % >30 % >30 % Dimensions (WxDxH), cm 50x40x60 50x40x60 50x40x60 25 L 25 L 25 L Tank dimensions (WxDxH), cm 30x25x50 30x25x50 30x25x50 Feed water pressure bar bar bar Feed water conductivity < 900 μs/cm < 900 μs/cm < 900 μs/cm Ordering Information Model Crystal B Trace CB-1015 Crystal B CB-1101 Crystal B Bio CB-1201 Consumables Description Replacement criteria Comments Replacement set, Crystal B Filter life counter is zero or the is clogged Replacement deionization DI Err message is shown, or water conductivity is consistently > 0.5 μs/cm Replacement polishing Every 1 2 years, depending on operation Replacement sterilization UV bulb As required (on average every 3 years) Bio systems only Replacement photooxidation UV bulb As required (on average every 3 years) and Bio systems Replacement 0.22 μm micro Every 6 12 months Trace and systems Replacement ultra Every 6 12 months Bio systems only 5

6 systems Integrity series Crystal Integrity systems produce ultrapure water directly from tap water. produced by the Crystal Integrity system complies with the requirements for Grade 1 water in accordance with relevant standards (ISO 3696, ASTM, CLSI). The Crystal Integrity systems are recommended for laboratories with relatively low consumption of ultrapure water (about 5 litres per day). Crystal Integrity systems are available in the following configurations: Integrity System (P/N CB-1503) produces water with very low organic carbon (TOC) content. This meets the re quirements for liquid chromatography methods. Integrity water can also be used for some microbiological and molecular biology appli cations. Applications Application Consumables Integrity Bio System (P/N CB- 1505) produces water with very low organic and RNase/DNase content. This is intended for use in molecular biology, including RNase-sensitive applications. Crystal Integrity water is intended for the most demanding applications including, but not limited to: inorganic trace analysis liquid chromatography cell culture molecular biology produced by an Integrity system, with resistivity of 18.2 MegaOhm*cm (0.055 μs/cm), exceeds requirements of all relevant standards (ISO 3696 Grade 1, ASTM Type I, CLSI Type I). Purified water is collected in an integrated storage. The recirculation system ensures consistent of water and reduces total organic carbon (TOC) to very low levels: <2ppb. Space-saving, integrated, 5L is made of high density polyethylene to minimize contamination. The storage is accessible for cleaning. Integrity Integrity Bio Reagent preparation Ion chromatography ICP-MS Atomic absorption spectrophotometry with graphite atomizer ICP-OES Gas chromatography Total Organic Carbon measurement cytometry Cell and tissue culture Molecular biology Components Accessory All Integrity systems have a controller with a graphic LCD display for water indication. The LCD display provides all necessary information about system status, remaining life, and polishing performance. The smart polishing monitoring system provides a reduction in running costs. Users are instructed to replace the polishing only when the is close to the end of its service life. If a Bluetooth option (P/N 10103) is installed, the controller can be detached. The Integrity system can be controlled remotely for more convenient operation. All cartridges and s are easily accessible and no tools are required to replace them. The Integrity system can be installed on a laboratory bench or mounted on the wall to save space. The Crystal Integrity has important safety functions, including: filling control tap water pressure control Integrity Integrity Bio Description Replacement criteria Comments Replacement set, Integrity Filter life counter is zero or the is clogged Replacement polishing DI Err message is shown, or water conductivity while dispensing is consistently > 0.1 μs/cm Replacement sterilization UV bulb As required (on average every 3 years) Bio systems only Replacement 0.22 μm micro As required (on average every 3 years) and Bio systems Replacement 0.22 μm micro Every 6 12 months systems only Replacement ultra Every 6 12 months Bio systems only Pre- set for chlorine and organics reduction reduction Polishing Photo-oxidation Point-of-use micro Point-of-use ultrafiltration UV sterilization Integrated TOC monitor option Removable controller with Bluetooth option option 6

7 diagrams (RO ) Shunting Polishing Final point of-use Check Protective Dual wavelength UV photooxidation (185/254 nm) Ultrapure water Integrity (RO ) UV sterilization (254 nm) Shunting Polishing Final point of-use Check Protective Dual wavelength UV photooxidation (185/254 nm) Ultrapure water Integrity Bio Specifications Purified water specifications Integrity Integrity Bio Ultrapure (Grade 1) water resistivity 18.2 MΩ x cm 18.2 MΩ x cm Ultrapure (Grade 1) water conductivity μs/cm μs/cm TOC <2 ppb <2 ppb RNase <0.01 ng/ml DNase <4 pg/μl Bacteria < 1 cfu/ml < 1 cfu/ml Endotoxins <0.15 EU/mL < EU/mL icles > 0.22 μm <1/ per ml <1/ per ml Nominal flow, pure water (to storage ) 4 L/h 4 L/h Nominal flow, ultrapure water 2 L/min 2 L/min Polishing life 1 m 3 1 m 3 Recovery >30 % >30 % Dimensions (WxDxH), cm 50x40x60 50x40x60 Integrated storage 5 L 5 L Feed water pressure bar bar Feed water conductivity < 900 μs/cm < 900 μs/cm Ordering Information Model Crystal Integrity Crystal Integrity Bio CB-1503 CB

8 systems Onsite series Adrona Onsite systems produce ultrapure water from pre-treated water. produced by the Adrona Onsite complies with the requirements for Grade 1 water for all relevant standards (ISO 3696, ASTM, CLSI). Adrona Onsite systems are recommended for laboratories with consumption of ultrapure water of 5-10 litres per day. Adrona Onsite systems are available in following configurations: Onsite System (P/N CB- 1803) produces water with very low organic carbon (TOC) content. This meets the requirements of liquid chromatography methods. Onsite water can also be used for some microbiology and molecular biology applications. Onsite Bio System (P/N CB- 1805) produces water with very low organic and RNase/DNase content. This is intended for use in molecular biology, including RNase-sensitive applications. Water produced by Adrona Onsite systems is intended for most demanding applications including, but not limited to: inorganic trace analysis liquid chromatography cell culture molecular biology produced by an Integrity system, with resistivity of 18.2 MegaOhm*cm (0.055 μs/cm), exceeds requirements of all relevant standards (ISO 3696 Grade 1, ASTM Type I, CLSI Type I). Crystal Onsite systems have integrated sto - rage. The storage should be filled with pre-treated water by the operator. Pre-treated water may be obtained from a water still, or a reverse system. The Crystal Onsite system comes with a 5L carboy. The carboy has a stopcock and handle for convenient transportation of water from a water still to the Crystal Onsite unit. The recirculation system ensures a consistent of water and reduces total organic carbon (TOC) to a very low level: <2ppb. A space-saving, integrated, 5L is made of high-density polyethylene to minimize contamination. The 5L is accessible for cleaning. All Crystal Onsite systems have a controller with a graphic LCD display for water indication. The LCD display provides all the necessary information about system status, remaining life, and the polishing performance. The smart polishing monitoring system provides a reduction in running costs. The user is instructed to replace the polishing only when the is close to the end of it s service life. If a Bluetooth option (P/N 10103) is installed, the controller can be detached. The Onsite system can be controlled remotely for convenient operation. The Crystal Onsite has important safety functions including filling control. All cartridges and s are easily accessible and no tools are required to replace them. The Onsite system can be installed on a laboratory bench or mounted on the wall to save space. Applications Application Onsite Onsite Bio Reagent preparation Ion chromatography ICP-MS Atomic absorption spectrophotometry with graphite atomizer ICP-OES Gas chromatography Total Organic Carbon measurement cytometry Cell and tissue culture Molecular biology Components Accessory Onsite Onsite Bio Polishing Photooxidation Point-of-use micro Point-of-use ultra filtration Integrated TOC monitor option Removable controller with Bluetooth option option 8

9 diagrams Shunting Polishing Final point of-use Shunting Polishing Final point of-use Protective Dual wavelength UV photooxidation (185/254 nm) Ultrapure water Onsite Protective Dual wavelength UV photooxidation (185/254 nm) Ultrapure water Onsite Bio Specifications Purified water specifications Onsite Onsite Bio Ultrapure (Grade 1) water resistivity 18.2 MΩ x cm 18.2 MΩ x cm Ultrapure (Grade 1) water conductivity μs/cm μs/cm TOC <2 ppb <2 ppb RNase <0.01 ng/ml DNase <4 pg/μl Bacteria < 1 cfu/ml < 1 cfu/ml Endotoxins <0.15 EU/mL < EU/mL icles > 0.22 μm <1/ per ml <1/ per ml Nominal flow, ultrapure water 2 L/min 2 L/min Polishing life 1 m 3 1 m 3 Recovery >30 % >30 % Dimensions (WxDxH), cm 50x40x60 50x40x60 Integrated storage 5 L 5 L Feed water conductivity < 15 μs/cm < 15 μs/cm Ordering Information Model Crystal Onsite CB-1803 Crystal Onsite Bio CB-1805 Consumables Description Replacement criteria Comments Replacement polishing DI Err message is shown, or water conductivity while dispensing is consistently > 0.1 μs/cm Replacement 0.22 μm micro As required (on average every 3 years) and Bio systems Replacement 0.22 μm micro Every 6 12 months systems only Replacement ultra Every 6 12 months Bio systems only 9

10 systems Crystal B Pure series The Crystal B Pure systems produce purified water for general laboratory applications and analytical inorganic methods. Crystal B complies with the requirements of ISO 3696 Grade 2. The costs of production are lower in comparison to the costs of. Pure (Grade 2) water complies with the requirements of a variety of applications, including: Many inorganic methods of analysis (e. g. flame spectrometry) Wet chemistry methods Electrochemistry Labware washing, etc. The Crystal B Pure systems are designed to provide a lab with water that is essentially free from dissolved ions and has a low TOC content. The conductivity of Crystal B is less than 0.1 μs/ cm. This exceeds the requirements for Grade 2 water put forth in ISO Applications Application Glassware rinsing Laboratory washers Autoclaves Electrochemistry Flame AAS Wet chemistry Spectrophotometry Buffer and media preparation Crystal B Pure 10 Crystal B Pure systems are equipped with a user-friendly control. The control has a graphic LCD display with indication of water. The Bluetooth option (P/N 10103) provides remote control of the Crystal B system via the detachable controller. The Crystal B system can be installed on a wall or under a bench, thus saving valuable laboratory space. The controller provides information about the system status; including remaining life and deionization (DI) performance. The smart DI mo- Specifications Purified water specifications Crystal B Pure Purified water resistivity >10 MΩ x cm Purified water conductivity <0.1 μs/cm icles > 0.22 μm <1 per ml Nominal flow, pure water (to storage ) 10 L/h Dispense flow, pure water 4 L/min Deionization life (standard ) 1 m 3 Recovery >30 % Dimensions (WxDxH), cm 50x40x60 (option) 25 L 300 L Feed water pressure bar Feed water conductivity < 900 μs/cm

11 dule monitoring system provides a reduction in running costs. The user is instructed to replace the DI only when the is near the end of it s service life. diagram Crystal B Pure A storage for purified water is available as an option. We offer storage s with capacities ranging from 10L 60L. All s with a capacity of 25L and higher have integrated s for fast and convenient dispensing. The dispensing flow rate is 4 L/min. An integrated enables placement of the storage under a bench, if desired, to save more space. The Crystal B has important safety functions, including: Tank filling control, tap water pressure control, and protection from failure. (RO ) Check Deionization Pure (Grade 2) water The Crystal B systems include: Pre- set Deionization A UV sterilization is available as an option (P/N 10102). Ordering Information Model Components Accessory Crystal B Pure Pre- for chlorine and organics reduction Deionization, standard + Crystal B Pure CB UV sterilization option Removable controller with Bluetooth option s Accessory Basic w/, 25L Crystal B Pure option Tiny, 10L option Comfort w/, 60L Economy w/, 50L option option Consumables Description Replacement criteria Comments Replacement set, Crystal B Replacement deionization Replacement sterilization UV bulb Filter life counter is zero or the is clogged DI Err message is shown, or water conductivity is consistently > 0.5 μs/cm As required (on average every 3 years) Systems with option only 11

12 ULTRAPURE WATER SYSTEMS series 12 The ultrapure systems are economy class, multi-purpose, water purification systems. ultrapure water systems are available in the following configurations: Trace System (P/N CE- 1001) produces water for inorganic trace analysis. This water is recommended for atomic absorption spectrometry (with graphite furnace atomizer), ICP- OES analysis, ICP-MS and other inorganic analytical methods. System (P/N CE- 1101) produces water with very low organic carbon content (TOC) to comply with the requirements of liquid chromatography methods. water can also be used for some microbiological and molecular biology applications. Bio System (P/N CE- 1201) produces water with very low organic and RNase/DNase content, intended for molecular biology, including RNase-sensitive applications. All systems produce two types of water: Ultrapure (ISO 3696 Grade 1) and Pure (ISO 3696 Grade 2). produced by the systems has resistivity 18.2 MegaOhm*cm (conductivity μs/cm). This exceeds requirements of all the relevant standards (ISO 3696 Grade 1, ASTM Type I, CLSI Type I). Purified water is collected in a storage. The recirculation system ensures a consistent of water, and a low level of organic carbon content (TOC). TOC is <2ppb for and Bio configurations; and 5-10 ppb for the Trace configuration. The dispensing rate of high-, is 2 L/min. produced by systems can be used for labware washing, wet chemistry methods, flame spectrophotometers, etc.. is d directly from the storage. The dispensing flow rate of is 4 L/min. All systems have a graphic LCD display that provides a clear water readout. The display also provides information about the system status. This includes current resistivity and remaining pre service life. The smart deionization (DI) performance monitoring system provides a reduction in running costs. All cartridge and replacement can Ordering Information Model Trace Bio CE-1001 CE-1101 CE-1201 be done by the operator and no tools are required. The systems include important safety functions, such as: filling control tap water pressure control protection from a failure Running costs can be decreased even more by installing an 8L deionization option (P/N 10101). systems include: Pre- RO Deionization Polishing 25L storage with integrated Grade 2 dispensing system Point-of-use Final Filter: 0.22 μm micro for Crystal E Trace and systems ultra for Bio systems Photo-oxidation for reduction of organics (for and Bio configurations) UV sterilization (for the Bio configuration)

13 diagrams (RO ) Deionization Shunting Final point of-use Check Polishing Protective Ultrapure water Pure (Grade 2) water Trace (RO ) Deionization Shunting Polishing Final point of-use Check Protective Dual wavelength UV photooxidation (185/254 nm) Ultrapure water Pure (Grade 2) water (RO ) Deionization UV sterilization Check (254 nm) Shunting Polishing Final point of-use Protective Dual wavelength UV photooxidation (185/254 nm) Ultrapure water Pure (Grade 2) water Bio 13

14 14 Components Consumables Accessory Trace Description Replacement criteria Comments Replacement, Replacement deionization Replacement high-capacity deionization Replacement polishing Replacement sterilization UV bulb Replacement photooxidation UV bulb Replacement 0.22 μm micro Bio Pre- for chlorine and organics reduction Deionization, standard High capacity deionization, (replaces standard option option option ) Polishing Photo-oxidation Point-of-use micro Point-of-use ultrafiltration UV sterilization + Filter life counter is zero or the is clogged DI Err message is shown, or water conductivity is consistently > 0.5 μs/cm DI Err message is shown, or water conductivity is consistently > 0.5 μs/cm Every 1 2 years, depending on operation As required (on average every 3 years) As required (on average every 3 years) Systems with option only Bio systems only and Bio systems only Every 6 12 months Trace and systems Replacement ultra Every 6 12 months Bio systems only Specifications Applications Application Trace Bio Reagent preparation Ion chromatography ICP-MS Atomic absorption ICP-OES Gas chromatography Total Organic Carbon cytometry Cell and tissue culture Molecular biology Purified water specifications Trace Bio Grade 2 water resistivity >10 MΩ x cm >10 MΩ x cm >10 MΩ x cm Grade 2 water conductivity <0.1 μs/cm <0.1 μs/cm <0.1 μs/cm Grade 1 water resistivity 18.2 MΩ x cm 18.2 MΩ x cm 18.2 MΩ x cm Grade 1 water conductivity μs/cm μs/cm μs/cm TOC 5 10 ppb <2 ppb <2 ppb RNase N/A N/A <0.01 ng/ml DNase N/A N/A <4 pg/μl Bacteria < 1 cfu/ml < 1 cfu/ml < 1 cfu/ml Endotoxins <0.15 EU/mL <0.15 EU/mL < EU/mL icles > 0.22 μm <1 per ml <1 per ml <1 per ml Nominal flow, pure water (to storage ) 10 L/h 10 L/h 10 L/h Nominal flow, ultrapure water 2 L/min 2 L/min 2 L/min Nominal flow, pure water 4 L/min 4 L/min 4 L/min Deionization life (standard ) 1 m 3 1 m 3 1 m 3 Deionization life (high capacity ) 3 m 3 3 m 3 3 m 3 Recovery >30 % >30 % >30 % Dimensions (WxDxH), cm 40x35x55 40x35x55 40x35x55 25 L 25 L 25 L Tank dimensions (WxDxH), cm 30x25x50 30x25x50 30x25x50 Feed water pressure bar bar bar Feed water conductivity < 900 μs/cm < 900 μs/cm < 900 μs/cm

15 systems Pure and RO series RO and Pure systems produce purified water of ISO 3696 Grade 3 (RO) and ISO 3696 Grade 2 (Pure). Pure and RO water have much lower production costs than ultrapure (Grade 1) water. Pure and RO water comply with the requirements of a variety of applications, including: Many inorganic methods of analysis (e. g. flame spectrophotometry) Wet chemistry methods Electrochemistry Labware washing, etc. The RO system reduces contamination in water by more than 98%. The conductivity of RO purified water is typically less than 5 μs/cm (dependent Specifications upon feed water). The Pure system produces water that is essentially free from inorganic contamination, and low in TOC content. The conductivity of water produced by the Crystal E Pure system is less than 0.1 μs/ cm. This exceeds the requirements for Grade 2 water according to ISO s of various sizes are available as an option for the Pure water system. The capacity of the s range from 10L to 300L. All s with a capacity of 25L or higher have integrated s for fast and convenient dispensing. The dispensing flow rate is 4 L/min. An integrated allows placement of the storage under a bench, if needed, to save space. The RO and Pure have a graphic LCD display providing indication of water, system status, and remaining life. The smart DI performance monitoring system provides a reduction in system running costs. All cartridge and replacement can be done by the operator without tools. The provides important safety functions, including: filling control tap water pressure control protection from failure. High-Consumption Laboratories and Applications: We offer the 20 Pure system for high consumption (30 L/day and more) applications. This includes a high capacity (8L) deionization. The high capacity provides a reduction in system running costs. It is also possible to order 8L option (P/N 10101) for the Crystal E Pure system. The systems include: Pre- Deionization (for Pure systems only) A UV-sterilization is available as an option (P/N 10102). Purified water specifications RO 20 Pure Pure Purified water resistivity >10 MΩ x cm >10 MΩ x cm Purified water conductivity <5 μs/cm <0.1 μs/cm <0.1 μs/cm icles > 0.22 μm <1 per ml <1 per ml <1 per ml Nominal flow, pure water (to storage ) 10 L/h 20 L/h 10 L/h Dispense flow, pure water 4 L/min 4 L/min 4 L/min Deionization life (standard ) N/A N/A 1 m 3 Deionization life (high capacity ) N/A 3 m 3 3 m 3 (optional) Recovery >30 % >30 % >30 % Dimensions (WxDxH), cm 40x35x55 40x50x55 40x35x55 (option) 25 L 300 L 25 L 300 L 25 L 300 L 25L dimensions (WxDxH), cm 30x25x50 30x25x50 30x25x50 Feed water pressure bar bar bar Feed water conductivity < 900 μs/cm < 900 μs/cm < 900 μs/cm 15

16 diagrams (RO ) Check Pure (Grade 2) water RO (RO ) Deionization Check Pure (Grade 2) water Pure (RO ) Deionization Check Pure (Grade 2) water 20 Pure 16

17 Applications Application Crystal E RO Crystal E Pure Glassware rinsing Laboratory washers Autoclaves Electrochemistry Flame AAS Wet chemistry Spectrophotometry Buffer and media preparation Components Accessory Pre- for chlorine and organics reduction Pre- set for chlorine and organics reduction RO Crystal E20 Pure Crystal Pure E Deionization, standard High capacity deionization, (replaces standard ) + option Point-of-use microfiltration for Pure systems option option UV sterilization option option s Accessory RO Crystal E20 Pure Pure Basic w/, 25L option option option Comfort w/, 60L option option option Economy w/, 50L option option option Tiny, 10L option option option Comfort w/, 100L option option option Ordering Information Model Pure CE Comfort w/, 200L option option option Comfort w/, 300L option option option RO 20 Pure CE-1245 C HC Consumables Description Replacement criteria Comments Replacement, RO, Pure Filter life counter is zero or the is clogged Replacement set, 20 Pure Filter life counter is zero or the is clogged Replacement deionization DI Err message is shown, or water conductivity is consistently > 0.5 μs/cm Pure systems only Replacement high-capacity deionization DI Err message is shown, or water conductivity is consistently > 0.5 μs/cm Only E20 Pure or systems with option Replacement sterilization UV bulb As required (on average every 3 years) Only systems with option Replacement 0.22 μm Every 6 12 months Only systems with option 17

18 systems Crystal 7 RO and Pure series The Crystal 7 Pure system (P/N C7-1001) is an entry level water purification system with very low system running costs. It is wall-mounted and does not require any space on a laboratory bench. The Crystal 7 Pure system produces purified water for general laboratory applications and analytical methods. Crystal 7 system water is used for many applications, including: Many inorganic methods of analysis (e. g. flame spectrophotometry) Wet chemistry methods Electrochemistry Labware washing, etc. The Crystal 7 Pure system is a reliable source of purified lab water with conductivity < 0.1 μs/cm (resistivity > 10 MegaOhm*cm). This exceeds requirements for Grade 2 water according to ISO The operating costs of a Crystal 7 Pure system are extremely low. The Crystal 7 RO system (P/N C7-1241) produces water that complies with ISO 3696 Grade 3 requirements. Specifications The Crystal 7 Pure and RO systems are equipped with a graphic LCD display providing system status info and water monitoring readouts. The remaining life and deionization (DI) performance are shown on the LCD display. The smart DI monitoring system provides a reduction in system operating costs. Users are instructed to replace the DI only when the is near the end of its service life. s for purified water are an available option. We offer storage s ranging in capacity from 10L 60L. Tanks of 25L or more have integrated s for fast and convenient dispensing. The dispensing flow rate is 4 L/min. All cartridges and s are easy to access and replace. An integrated allows users to place the storage under a bench, if desired, to save space. The Crystal 7 system has important safety functions, including: filling control tap water pressure control protection from failure The Crystal 7 systems include: boost set reverse deionization A UV-sterilization is available as an option (P/N 10102). Ordering Information Model Crystal 7 Pure C Crystal 7 RO C Purified water specifications Crystal 7 RO Crystal 7 Pure Purified water resistivity >10 MΩ x cm Purified water conductivity <5 μs/cm <0.1 μs/cm icles > 0.22 μm <1 per ml <1 per ml Nominal flow, pure water (to storage ) 7 L/h 7 L/h Dispense flow, pure water 4 L/min 4 L/min Deionization life N/A 1 m 3 Recovery >30 % >30 % Dimensions (WxDxH), cm 50x20x52 50x20x52 (option) 10 L 60 L 10 L 60 L Feed water pressure bar bar Feed water conductivity < 900 μs/cm < 900 μs/cm s Accessory Crystal 7 RO Crystal 7 Pure Basic w/, 25L option option Comfort w/, 60L option option Economy w/, 50L option option Tiny, 10L option option 18

19 diagrams Crystal 7 RO (RO ) Check 1μm sediment Pure (Grade 2) water Crystal 7 Pure (RO ) Check Deionization 1μm sediment Pure (Grade 2) water Applications Application Crystal 7 RO Crystal 7 Pure Glassware rinsing Laboratory washers Autoclaves Electrochemistry Flame AAS Wet chemistry Spectrophotometry Buffer and media preparation Components Accessory Crystal 7 RO Pre- set for chlorine and organics reduction Crystal 7 Pure Deionization pack UV sterilization option Consumables Description Replacement criteria Comments Replacement set, Crystal 7 Replacement deionization Replacement sterilization UV bulb Filter life counter is zero or the is clogged DI Err message is shown, or water conductivity is consistently > 0.5 μs/cm As required (on average every 3 years) Systems with option only 19

20 systems Sterifeed Sterifeed is a water purification system that is designed to produce feed water for autoclaves. The Sterifeed system produces water with conductivity of 5-11 us/cm. This is within the recommended conductivity range of 3-15 us/cm, presented by autoclave manufacturers. Specifications Water with a conductivity reading above 15 us/cm facilitates salt deposits on heating elements, eventually leading to the failure of the heating element. Water with a conductivity below 3 us/cm can attack internal surfaces of the autoclave, thusly damaging water level s, heating elements, and connections. Sterifeed water provides optimal conductivity, within the range of 5-11 us/cm, granting reliable operation of the autoclave. A pressurized water storage provides a consistent water supply to the autoclave. Many autoclaves require a pressurized and purified water supply. Some autoclaves have priming s for purified water intake, but if the water supply is not pressurized, an air gap may block the water flow. If an air blockage occurs, the operation of autoclave is not possible until the air is removed from the system. The pressurized water storage of the Sterifeed system eliminates the formation of air gaps, and ensures reliable operation of the autoclave. The Sterifeed system has an LCD display that provides information about the system status, water, and the remaining life. The water softening ensures long life of the purifying elements. These design features reduce the operational costs for your laboratory. Purified water specifications Sterifeed Purified water resistivity Purified water conductivity 5-11 μs/cm icles > 0.22 μm <1 per ml Nominal flow, pure water (to storage ) 10 L/h Deionization life N/A Recovery >30 % Dimensions (WxDxH), cm 50x20x52 Pressurized storage 60 L Tanks dimensions, cm 42x42x60 Feed water pressure bar Feed water conductivity < 900 μs/cm The Sterifeed comes with the necessary accessories for connection to an autoclave, and no tools are required! 20

21 diagram (RO ) 5 μm sediment 1 μm sediment Check To autoclave Pressurized storage Softening cartridge Carbon cartridge Consumables Description Replacement criteria Comments Replacement set, Sterifeed Filter life counter is zero or the is clogged Ordering Information Model Crystal Sterifeed CS

22 systems Crystal Clinic The Crystal Clinic water purification system is designed to provide purified water to automated biochemistry analyzers. Purified water ensures long-term, reliable operation from a biochemistry analyzer. Water produced from the Crystal Clinic has a resistivity of 10 MegaOhm*cm. This exceeds the manufacturers requirements for feed water to biochemistry analyzers. A double RO and pressurized 60L ensure a stable and reliable supply of water. The Crystal Clinic systems are equipped with a pressure regulator. Purified water pressure is precisely adjusted to the requirements of the analyzer. The Crystal Clinic has two reverse s and a high-capacity deionization cartridge (DI). The large DI cartridge volume significantly reduces operating costs. Water purified by the reverse s is collected in the storage.the water is then polished to 10 MegaOhm*cm by the deionization. The two reverse s enable a high flow rate through the permeable membranes, ensuring that purified water is always available. Pictures are for reference only. Depending on configuration, some options may not be present Specifications Purified water specifications Clinic Grade 2 water resistivity >10 MΩ x cm Grade 2 water conductivity <0.1 μs/cm icles > 0.22 μm <1 per ml Nominal flow, pure water (to storage ) 28 L/h Dispense flow to analyzer 4 L/min Dispense pressure 100 kpa Deionization life (high capacity ) 3 m 3 Recovery >30 % Dimensions (WxDxH), cm 40x50x55 Pressurized storage 60 L Tank dimensions, cm 42x42x60 Feed water pressure bar Feed water conductivity < 900 μs/cm A large LCD display provides information about the system status, water, and life. The Crystal Clinic has two water s. The first controls the of water filling the storage. This is shown on the LCD display while the is beeing filled. The second controls the of water supplied to the Biochemical Analyzer. The Crystal Clinic system automatically monitors the performance of the deionization and alerts the operator when the DI needs replacement. The DI and can be replaced by the operator. No tools required! The Crystal Clinic has a port on the front panel. Pure (Grade 2) water can be used for general laboratory applications. 22

23 diagram (RO ) Check regulator Deionization Pressurized storage To analyzer Final pointof-use Components Accessory Crystal Clinic Pre- set for chlorine and organics reduction + Ordering Information s + s High capacity deionization UV sterilization option Model Crystal Clinic CL-2810 Consumables Description Replacement criteria Comments Replacement set, Crystal Clinic Filter life counter is zero or the is clogged Replacement high-capacity deionization DI Err message is shown, or water conductivity > 0.1 μs/cm Replacement sterilization UV bulb As required (on average every 3 years) Only for systems equipped with 10102

24 Dzerbenes 27, Riga LATVIA, LV 1006 Tel.: , Fax:

LABORATORY PRODUCT GUIDE

LABORATORY PRODUCT GUIDE LABORATORY PRODUCT GUIDE THE NEXT GENERATION OF LABORATORY WATER PURIFICATION SYSTEMS PURITE WATER PURIFICATION SYSTEMS Purite specialises in the design, development and manufacture of advanced, high performance

More information

Thermo Scientific Barnstead TII Pure Water Systems. Pure water. Pure research. Total confidence.

Thermo Scientific Barnstead TII Pure Water Systems. Pure water. Pure research. Total confidence. Thermo Scientific Barnstead TII Pure Water Systems Pure water. Pure research. Total confidence. Thermo Scientific Barnstead TII Pure Water Systems Ideal for any daily application needs for pure water,

More information

PURELAB. Laboratory water purification systems

PURELAB. Laboratory water purification systems PURELAB Laboratory water purification systems PURELAB Water is all we do. We know water. We understand how important it is for scientists to obtain a choice of water qualities that range from primary grade,

More information

Direct Water purification system Pure & ultrapure water directly from tap water

Direct Water purification system Pure & ultrapure water directly from tap water Milli-Q Direct Water purification system Pure & ultrapure water directly from tap water ADVANCING LIFE SCIENCE TOGETHER Research. Development. Production. Pure & ultrapure water from a single water system

More information

Advantage System Elix The Best in Pure Water

Advantage System Elix The Best in Pure Water Advantage System Elix The Best in Pure Water ADVANCING LIFE SCIENCE TOGETHER Research. Development. Production. Elix Advantage System THE PURE WATER YOU VE ALWAYS IMAGINED Advanced Technology Productivity

More information

RiOs 3, 5, 8 Water Purification Systems

RiOs 3, 5, 8 Water Purification Systems RiOs 3, 5, 8 Water Purification Systems Reliable and affordable pure water solutions Merck Millipore is a division of Reliable and affordable pure water solutions Your water purification needs Reliable,

More information

Water for Injection (WFI) and Pure Steam Production in a Lean Manufacturing Environment. Larry Zanko Project Manager STERIS Corporation

Water for Injection (WFI) and Pure Steam Production in a Lean Manufacturing Environment. Larry Zanko Project Manager STERIS Corporation Water for Injection (WFI) and Pure Steam Production in a Lean Manufacturing Environment Larry Zanko Project Manager STERIS Corporation Agenda Brief overview of multiple-effect water stills (MWS) Lean advancements

More information

Laboratory Water. Its Importance and Application

Laboratory Water. Its Importance and Application Laboratory Water Its Importance and Application March, 2013 Table of Contents OVERVIEW... 3 WHAT ARE COMMON WATER CONTAMINANTS?... 3 HOW DO WE MEASURE CONTAMINANTS IN WATER?... 4 WHAT DOES LAB WATER GRADE

More information

ECOAZUR BLUEWATER WATER PURIFICATION PLANTS

ECOAZUR BLUEWATER WATER PURIFICATION PLANTS ECOAZUR BLUEWATER WATER PURIFICATION PLANTS CONTACT EcoAzur Calle 11a #492 x 60 y 62 Tel: +52-999-920-1972 Col. Residencial Pensiones Email: info@eco-azur.com C.P. 97217 Merida, Yucatan, Mexico Website:

More information

Water Purification Solutions

Water Purification Solutions Water Purification Solutions For Clinical Analyzers EMD Millipore is a division of Merck KGaA, Darmstadt, Germany Consistent high quality purified water A consistent water quality is essential to guaranteeing

More information

arium Water Purification Systems

arium Water Purification Systems arium Water Purification Systems A Profile of Sartorius Stedim Biotech Sartorius Stedim Biotech is a leading provider of cutting edge equipment and services for the development, quality assurance and production

More information

Lecture 30: Cleanroom design and contamination control

Lecture 30: Cleanroom design and contamination control Lecture 30: Cleanroom design and contamination control Contents 1 Introduction 1 2 Contaminant types 2 2.1 Particles.............................. 2 2.2 Metal ions............................. 4 2.3 Chemicals.............................

More information

Microbiological Testing of the Sawyer Mini Filter. 16 December 2013. Summary

Microbiological Testing of the Sawyer Mini Filter. 16 December 2013. Summary Microbiological Testing of the Sawyer Mini Filter 16 December 2013 Summary The Sawyer Mini Filter was tested for its ability to remove three microorganisms Raoultella terrigena, Bacillus subtilis, and

More information

User Manual. Milli-Q Integral 3/5/10/15 Systems

User Manual. Milli-Q Integral 3/5/10/15 Systems User Manual Milli-Q Integral 3/5/10/15 Systems About this User Manual Purpose This User Manual is intended for use with a Milli-Q Integral Water Purification System. This User Manual is a guide for use

More information

To meet the demands of a high-purity deionized (DI) water system, filters must:

To meet the demands of a high-purity deionized (DI) water system, filters must: Ultrapure Water General Filter Requirements Achieving and maintaining ultrapure water (UPW) is extremely important in light of its widespread presence throughout the manufacture of semiconductor integrated

More information

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer 450 Analyzer 450 Analyzer Fast, Continuous Measurement Compliant with USP, Ch P, EP and JP USB Data Logging and Printer Output Robust Portable Design Portable, Real-time, Continuous Total Organic Carbon

More information

PURE LABWATER GUIDE. An essential overview of lab water purification applications, monitoring and standards.

PURE LABWATER GUIDE. An essential overview of lab water purification applications, monitoring and standards. PURE LABWATER GUIDE An essential overview of lab water purification applications, monitoring and standards. 1-2 Introduction THE PURE LABWATER GUIDE Introduction Contents 1 Introduction 1-4 2 Research

More information

Cartridge Filter Application Notes

Cartridge Filter Application Notes Industrial Water Purification (800) CAL-WATER Cal Water 1961 Petra Lane Placentia, CA 92870 FAX: (714) 792-0794 Web Page / Email: www.cal-water.com Cartridge Filter Application Notes Cal Water offers a

More information

User Manual DIRECT-Q 3 SYSTEM DIRECT-Q 3 UV SYSTEM

User Manual DIRECT-Q 3 SYSTEM DIRECT-Q 3 UV SYSTEM User Manual DIRECT-Q 3 SYSTEM DIRECT-Q 3 UV SYSTEM Notice The information in this document is subject to change without notice and should not be construed as a commitment by Millipore Corporation. Millipore

More information

Drinking water for Gaza Elaboration concept 2

Drinking water for Gaza Elaboration concept 2 Herontwerp 2014 Drinking water for Gaza Elaboration concept 2 Docent: Hassanpur Golriz, D. (Damon) Student: Roger Sylverstre Yapo (Group 4) Content 1) Reverse osmosis description --------------------------------------------------------------------------

More information

Dissolved Oxygen Sensors

Dissolved Oxygen Sensors Instruction Sheet PN 51A-HxDO/rev.F June 2008 Models Hx438 and Gx448 Dissolved Oxygen Sensors For additional information, please refer to the Instruction Manuals CD shipped with this product, or visit

More information

The Sievers 900 Series TOC Analyzers

The Sievers 900 Series TOC Analyzers GE Water & Process Technologies Analytical Instruments The Sievers 900 Series TOC Analyzers imagination at work Delivering Next-Generation Ease of Use, Productivity, and Reliability The Sievers* 900 Series

More information

Rain Cloud (C-21) Product Specifications

Rain Cloud (C-21) Product Specifications Rain Cloud (C-21) Product Specifications RAIN CLOUD SERIES RAIN CLOUD (C-21) Single Page Brochure See Why People Are Talking About Their Planets Purest Water Maker Conserving water is good; creating your

More information

Life Sciences USD 2260. High Purity Water Systems for the Biopharmaceutical Industry. Improving security, flexibility and operation costs

Life Sciences USD 2260. High Purity Water Systems for the Biopharmaceutical Industry. Improving security, flexibility and operation costs Life Sciences USD 2260 High Purity Water Systems for the Biopharmaceutical Industry Improving security, flexibility and operation costs Pall's total turnover is more than $1.5billion. Our staff of more

More information

arium Water Purification Systems

arium Water Purification Systems arium Water Purification Systems The New arium Systems: Water Purification with Have you ever wanted application-focused operating features to make your daily lab routine work easier and your workflows

More information

Coating and Extraction of Honeycomb Denuders

Coating and Extraction of Honeycomb Denuders QSM Approval: Coating and Extraction of Honeycomb Denuders 1 INTRODUCTION 1.1 The following procedures are used for the coating of honeycomb denuders with citric acid and sodium carbonate solutions, and

More information

Water Info. What is Reverse Osmosis?

Water Info. What is Reverse Osmosis? Water Info What is Reverse Osmosis? Anyone who has been through a high school science class will likely be familiar with the term osmosis. The process was first described by a French Scientist in 1748,

More information

Horizontal Steam Sterilizers. Healthcare Line. Since

Horizontal Steam Sterilizers. Healthcare Line. Since Horizontal Steam Sterilizers Healthcare Line Since 1925 Horizontal Steam Sterilizers for Healthcare Applications The Tuttnauer line of healthcare sterilizers are designed for hospital operating rooms,

More information

Milli-Q Synthesis and Milli-Q Synthesis A10 User Manual

Milli-Q Synthesis and Milli-Q Synthesis A10 User Manual Milli-Q Synthesis and Milli-Q Synthesis A10 User Manual Notice The information in this document is subject to change without notice and should not be construed as a commitment by Millipore Corporation.

More information

Wastewater Reuse. Typical treated wastewater is:

Wastewater Reuse. Typical treated wastewater is: Wastewater Reuse Most metal finishing industries have in-house wastewater treatment to economically dispose of the acids, alkali, oils, and dissolved metals in the rinse water and occasional tank solution

More information

Innovation and Progress in Water Treatment Technology

Innovation and Progress in Water Treatment Technology Innovation and Progress in Water Treatment Technology Degree of separation of ultrafiltration Summary of the various processes The water will be pressed through the between the raw water side and the filtrate

More information

Contamination. Cleanroom. Cleanroom for micro and nano fabrication. Particle Contamination and Yield in Semiconductors.

Contamination. Cleanroom. Cleanroom for micro and nano fabrication. Particle Contamination and Yield in Semiconductors. Fe Particles Metallic contaminants Organic contaminants Surface roughness Au Particles SiO 2 or other thin films Contamination Na Cu Photoresist Interconnect Metal N, P Damages: Oxide breakdown, metal

More information

VIPCLEAN Via Goretta 96/A Mappano di Caselle (TO) Tel 011.2207783 Fax 011.2207927 e-mail info@vipclean.it

VIPCLEAN Via Goretta 96/A Mappano di Caselle (TO) Tel 011.2207783 Fax 011.2207927 e-mail info@vipclean.it INTRODUCTION VIP Clean, acronym of Very Important Purewater, is an exclusive and innovative line dedicated to cleaning systems with pure water. VIP Clean products are been designed and conceived to meet

More information

FilterFlow Automatic Water Boilers. Pure Quality

FilterFlow Automatic Water Boilers. Pure Quality FilterFlow Automatic Water Boilers Pure Quality Filtered hot water on tap Around the world we drink countless millions of cups of tea and coffee each and every day. The consumer s seemingly insatiable

More information

Dissolved and precipitated oxalate

Dissolved and precipitated oxalate Accepted 2005 Process liquors from bleach plants Dissolved and precipitated oxalate Using Ion Chromatography 0 Introduction In bleach plants of pulp mills with a high degree of system closure, there is

More information

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1. Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY I. BACKGROUND (VERSION 1.0) Atomic absorption spectroscopy (AAS) is a widely used

More information

Genomic DNA Extraction Kit INSTRUCTION MANUAL

Genomic DNA Extraction Kit INSTRUCTION MANUAL Genomic DNA Extraction Kit INSTRUCTION MANUAL Table of Contents Introduction 3 Kit Components 3 Storage Conditions 4 Recommended Equipment and Reagents 4 Introduction to the Protocol 4 General Overview

More information

limit to percentage levels, a limited working range translates

limit to percentage levels, a limited working range translates Figure 1. The AutoPrep 50 Automatic Dilution System. Figure 2. Schematic diagram of the AutoPrep 50. Flame atomic absorption spectroscopy (flame AA) is still the most frequently used instrumental technique

More information

UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 5 RESEARCH PLACE ROCKVILLE, MD 20850

UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 5 RESEARCH PLACE ROCKVILLE, MD 20850 UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 5 RESEARCH PLACE ROCKVILLE, MD 20850 Test Method: CPSC-CH-E1001-08.2 Standard Operating Procedure

More information

Complete. Water Solutions. for Rural India

Complete. Water Solutions. for Rural India Complete Water Solutions for Rural India More precious than gold. That s what safe drinking water is to India s rural population. Arsenic, iron, fluoride, nitrate, brackishness and pathogens in ground

More information

Troubleshooting Your RO

Troubleshooting Your RO Troubleshooting Your RO Summary: There can be many reasons why a RO system suffers a loss in performance, and is unable to produce the proper quantity and/or quality of permeate water. Similar to a doctor

More information

Design of Purified Water and Water For Injection Systems. Hugh Hodkinson Engineers Ireland Chemical & Process Division

Design of Purified Water and Water For Injection Systems. Hugh Hodkinson Engineers Ireland Chemical & Process Division Design of Purified Water and Water For Injection Systems Hugh Hodkinson Engineers Ireland Chemical & Process Division Introduction My Background What s this lecture about? What should you get out of it?

More information

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep Guide to Reverse Phase SpinColumns Chromatography for Sample Prep www.harvardapparatus.com Contents Introduction...2-3 Modes of Separation...4-6 Spin Column Efficiency...7-8 Fast Protein Analysis...9 Specifications...10

More information

FAMILY PROTECTION FROM WATERBORNE DISEASES

FAMILY PROTECTION FROM WATERBORNE DISEASES A Product by : GIVE A 100% FAMILY PROTECTION FROM WATERBORNE DISEASES CATALOGUE 100% SAFE WATER LATEST JAPAN TECHNOLOGY ABOUT US We are introducing a unique Water Purifier with the proud name of Harshali

More information

50 g 650 L. *Average yields will vary depending upon a number of factors including type of phage, growth conditions used and developmental stage.

50 g 650 L. *Average yields will vary depending upon a number of factors including type of phage, growth conditions used and developmental stage. 3430 Schmon Parkway Thorold, ON, Canada L2V 4Y6 Phone: 866-667-4362 (905) 227-8848 Fax: (905) 227-1061 Email: techsupport@norgenbiotek.com Phage DNA Isolation Kit Product # 46800, 46850 Product Insert

More information

Cal Water 1961 Petra Lane, Placentia, CA 92870 (800) CAL-WATER (800) 225-9283 FAX: (714) 792-0794 http://www.cal-water.com

Cal Water 1961 Petra Lane, Placentia, CA 92870 (800) CAL-WATER (800) 225-9283 FAX: (714) 792-0794 http://www.cal-water.com Industrial Water Purification MAINTAINING A STERILE HIGH PURITY WATER SYSTEM Introduction Maintaining a microbe free deionized water system is like trying to maintain a vacuum, and nature abhors a vacuum.

More information

UltraClean PCR Clean-Up Kit

UltraClean PCR Clean-Up Kit UltraClean PCR Clean-Up Kit Catalog No. Quantity 12500-50 50 Preps 12500-100 100 Preps 12500-250 250 Preps Instruction Manual Please recycle Version: 02212013 1 Table of Contents Introduction... 3 Protocol

More information

Basics of Reverse Osmosis

Basics of Reverse Osmosis What is Reverse Osmosis? Reverse Osmosis is a technology that is used to remove a large majority of contaminants from water by pushing the water under pressure through a semi- permeable membrane. This

More information

A new wave in instrument washing and disinfection Introducing the new HYDRIM G4 WD series

A new wave in instrument washing and disinfection Introducing the new HYDRIM G4 WD series A new wave in instrument washing and disinfection Introducing the new HYDRIM G4 WD series Taking control of your infection control The hazards of manual cleaning Hand scrubbing is increasingly used less

More information

4 Stage Barracuda RO/DI Instruction & Owner s Manual

4 Stage Barracuda RO/DI Instruction & Owner s Manual 4 Stage Barracuda RO/DI Instruction & Owner s Manual 7208 Aloma Ave Suite 600 Winter Park, FL 32792 Phone 407-599-2123 Fax 407-599-2124 www.aquariumwaterfilters.com www.aquafx.net 7208 Aloma Ave Suite

More information

105 Adopted: 27.07.95

105 Adopted: 27.07.95 105 Adopted: 27.07.95 OECD GUIDELINE FOR THE TESTING OF CHEMICALS Adopted by the Council on 27 th July 1995 Water Solubility INTRODUCTION 1. This guideline is a revised version of the original Guideline

More information

ROSS Technology Removal of Oil, Solids and Scale Formers

ROSS Technology Removal of Oil, Solids and Scale Formers ROSS Technology Removal of Oil, Solids and Scale Formers Frac Flowback and Produced Treatment for Reuse WATER TECHNOLOGIES Treatment for Reuse and Enhanced Oil Recovery ROSS Technology is a an effective

More information

University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence)

University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence) University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence) For this laboratory exercise, you will explore a variety of spectroscopic methods used in an analytical

More information

Membrane Filtration Technology: Meeting Today s Water Treatment Challenges

Membrane Filtration Technology: Meeting Today s Water Treatment Challenges Membrane Filtration Technology: Meeting Today s Water Treatment Challenges Growing global demand for clean water and increasing environmental concerns make membrane filtration the technology of choice

More information

HiPer Ion Exchange Chromatography Teaching Kit

HiPer Ion Exchange Chromatography Teaching Kit HiPer Ion Exchange Chromatography Teaching Kit Product Code: HTC001 Number of experiments that can be performed: 5 Duration of Experiment: Protocol: 5-6 hours Storage Instructions: The kit is stable for

More information

Liquid II Cell Culture Media Manufacturing Plant. Overview Facilities Water for Injection Sterile Environment Media Handling Cleanroom Interior

Liquid II Cell Culture Media Manufacturing Plant. Overview Facilities Water for Injection Sterile Environment Media Handling Cleanroom Interior Liquid II Cell Culture Media Manufacturing Plant Overview Facilities Water for Injection Sterile Environment Media Handling Cleanroom Interior Overview History of BioConcept and Amimed BioConcept has close

More information

3 - Atomic Absorption Spectroscopy

3 - Atomic Absorption Spectroscopy 3 - Atomic Absorption Spectroscopy Introduction Atomic-absorption (AA) spectroscopy uses the absorption of light to measure the concentration of gas-phase atoms. Since samples are usually liquids or solids,

More information

BIOFIL Terminal Filters

BIOFIL Terminal Filters Controlling waterborne health risks BIOSAFE The prevention of health risks associated with pathogenic bacteria in water systems should be a constant concern for buildings open to the public and in particular

More information

HUBER Vacuum Rotation Membrane VRM Bioreactor

HUBER Vacuum Rotation Membrane VRM Bioreactor HUBER Vacuum Rotation Membrane VRM Bioreactor VRM The rotating plate membrane for clean water applications. The future-oriented solution designed for the ever increasing requirements in wastewater treatment

More information

AUTOCLAVE STEAM STERILIZERS

AUTOCLAVE STEAM STERILIZERS AUTOCLAVE STEAM STERILIZERS (BENCH TOP) Image: HS-1606VD Hanshin Bench Top Steam Sterilizer Small and easy to operate Three preset sterilization cycles Adjustable cycle presets Rapid heat up times Option

More information

the importance of ph in water purification the importance of ph in water purification Water Purification Systems UK

the importance of ph in water purification the importance of ph in water purification Water Purification Systems UK the importance of ph in water purification Water Purification Systems UK What is ph? The ph scale has been in use for over a century, ever since it was first defined in 1909 by the Danish chemist, Søren

More information

MILESTONE CLEAN CHEMISTRY LINE DUOPUR TRACECLEAN ULTRA-TRACE INSERTS. A Breakthrough in Reduction and Control of the Analytical Blank MILESTONE

MILESTONE CLEAN CHEMISTRY LINE DUOPUR TRACECLEAN ULTRA-TRACE INSERTS. A Breakthrough in Reduction and Control of the Analytical Blank MILESTONE MILESTONE CLEAN CHEMISTRY LINE A Breakthrough in Reduction and Control of the Analytical Blank DUOPUR TRACECLEAN ULTRA-TRACE INSERTS MILESTONE MILESTONE CLEAN CHEMISTRY LINE An innovative and complete

More information

Elemental composition of commercial seasalts

Elemental composition of commercial seasalts Elemental composition of commercial seasalts M. J. Atkinson, Hawaii Institute of Marine Biology, PO Box 1346, Kanoehe, Hawaii 96744, and C. Bingman, Department of Biochemistry and Molecular Biophysics,

More information

AQUAPRO INDUSTRIAL CO.,LTD. Reverse Osmosis Parts Introduction

AQUAPRO INDUSTRIAL CO.,LTD. Reverse Osmosis Parts Introduction Reverse Osmosis Parts Introduction Reverse Osmosis Flow Chart AQUAPRO INDUSTRIAL CO.,LTD Triple Membrane WATER IMPROVER WATER IMPROVER 2 Reverse Osmosis Electrical Diagram AC-220V Power (2.0 point) (W)

More information

Use of Nano-scale materials in Water Purification

Use of Nano-scale materials in Water Purification Use of Nano-scale materials in Water Purification Robert Meservy Dept. Physics I chose this subject because I m a reefkeeper and as such have to use distilled water in order to not poison the corals and

More information

Durapore. High Throughput Flow Rates. Durapore 0.2 µm hydrophilic

Durapore. High Throughput Flow Rates. Durapore 0.2 µm hydrophilic  Durapore CBR 0.2 µm Bioburden Reduction Filters Lenntech Tel. +31-15-261.09.00 Fax. +31-15-261.62.89 DAT A SHEET For fine filtration of deionized water, in vitro diagnostics, oral suspensions, bulk pharmaceutical

More information

ORGANIC SAMPLE PREPARATION

ORGANIC SAMPLE PREPARATION ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,

More information

The Relationship between ph and Deionized Water

The Relationship between ph and Deionized Water The Relationship between ph and Deionized Water The basics of ph The topic of ph and water has been well documented over the years; however, there is still much confusion about its significance in high

More information

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater Document: AND Sol Env 08 2013 Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater Matrix specific sample preparation and testing methods for environmental waters

More information

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline EXPERIMENT 5 Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline UNKNOWN Submit a clean, labeled 100-mL volumetric flask to the instructor so that your unknown iron solution

More information

Elemental analyzer multi EA 5000

Elemental analyzer multi EA 5000 Elemental analyzer multi EA 5000 Analytik Jena AG Konrad-Zuse-Str. 1 07745 Jena/Germany www.analytik-jena.com info@analytik-jena.com 1/6 multi EA 5000 The multi EA 5000 is a powerful elemental analyzer

More information

Water Treatment and Reverse Osmosis Systems

Water Treatment and Reverse Osmosis Systems Water 2012 Treatment Pure Aqua, and Inc. Reverse All Rights Osmosis Reserved. ystems Worldwide Experience uperior Technology About the Company Pure Aqua is a company with a strong philosophy and drive

More information

Monoclonal Antibody Production: Building the Platform. Andrew Clutterbuck Eden Biodesign Ltd.

Monoclonal Antibody Production: Building the Platform. Andrew Clutterbuck Eden Biodesign Ltd. Monoclonal Antibody Production: Building the Platform Andrew Clutterbuck Eden Biodesign Ltd. Questions Questions are encouraged throughout the presentation and can be asked by using the email address provided

More information

Removal of Weakly-Ionized Species by EDI

Removal of Weakly-Ionized Species by EDI Technical Paper Removal of Weakly-Ionized Species by EDI Authors: Brian Hernon, Hilda Zanapalidou, Ted Prato and Li Zhang, Ionics This paper was originally presented at the 59th Annual International Water

More information

Reverse Osmosis Membranes for Wastewater Reclamation By Craig R. Bartels, PhD Hydranautics, 401 Jones Road, Oceanside California, USA 92054

Reverse Osmosis Membranes for Wastewater Reclamation By Craig R. Bartels, PhD Hydranautics, 401 Jones Road, Oceanside California, USA 92054 Reverse Osmosis Membranes for Wastewater Reclamation By Craig R. Bartels, PhD Hydranautics, 401 Jones Road, Oceanside California, USA 92054 Abstract Wastewater reclamation has become a viable alternative

More information

Clinic Washer-Disinfectors. Washer-Disinfector Line

Clinic Washer-Disinfectors. Washer-Disinfector Line Clinic Washer-Disinfectors Washer-Disinfector Line Easy-to-Use Washer-Disinfectors for Clinics The Clinic Range of Washer Disinfectors provides superior cleaning and disinfection combined with innovative

More information

There are various types of water

There are various types of water Qualification of Purified Water Systems David W. Vincent Validation Technologies, Inc. There are various types of water used in the pharmaceutical industry. Their usage in the actual formulation, in processing

More information

DOW Ultrafiltration. Case History. High Turbidity and Temperature Fluctuation No Obstacle for DOW Ultrafiltration

DOW Ultrafiltration. Case History. High Turbidity and Temperature Fluctuation No Obstacle for DOW Ultrafiltration Case History High Turbidity and Temperature Fluctuation No Obstacle for Site Information Location: HeBei, China Capacity: 12 m 3 /h (5283 gpm) Purpose: Pretreat sea water prior to RO system Time in Operation:

More information

Experiment 12- Classification of Matter Experiment

Experiment 12- Classification of Matter Experiment Experiment 12- Classification of Matter Experiment Matter can be classified into two groups: mixtures and pure substances. Mixtures are the most common form of matter and consist of mixtures of pure substances.

More information

Storage-stable Aqueous Solutions of Chlorine Dioxide

Storage-stable Aqueous Solutions of Chlorine Dioxide White Paper Storage-stable Aqueous Solutions of Chlorine Dioxide Tom McWhorter November 14, 2014 Abstract Chlorine dioxide is a powerful, selective biocide. Aqueous solutions of chlorine dioxide have many

More information

Watts Family of water quality improvement products and equipment for whole house water treatment.

Watts Family of water quality improvement products and equipment for whole house water treatment. WATER QUALITY & CONDITIONING PRODUCTS Arsenic Iron Taste odors chlorine Hardness Turbidity Acid Water Taste odors chlorine sediment Watts Family of water quality improvement products and equipment for

More information

Determination of Calcium and Magnesium in Brine

Determination of Calcium and Magnesium in Brine Application Note Determination of Calcium and Magnesium in Brine INTRODUCTION To prevent membrane poisoning, new membrane technology in chlor-alkali cells requires feed brine that is relatively free of

More information

BY UV SPECTROPHOTOMETRY

BY UV SPECTROPHOTOMETRY 1 of 9 1. PURPOSE This Standard Operating Procedure describes the method for measuring the concentration of viral particles using UV/Vis spectrophotometry at 260 and 280 nm. 2. SCOPE This procedure is

More information

NITRIC OXIDE and NITROGEN DIOXIDE 6014

NITRIC OXIDE and NITROGEN DIOXIDE 6014 NITRIC OXIDE and NITROGEN DIOXIDE 6014 NO MW: 30.01 CAS: 10102-43-9 RTECS: QX0525000 46.01 10102-44-0 QW9800000 METHOD: 6014, Issue 1 EVALUATION: FULL Issue 1: 15 August 1994 OSHA : 25 ppm NO; C 1 ppm

More information

AQUADA UV Eliminate Bacteria in Your Drinking Water!

AQUADA UV Eliminate Bacteria in Your Drinking Water! AQUADA UV Eliminate Bacteria in Your Drinking Water! Protect your Family from Micro-Organisms Legionella pneumophila Legionella pneumophila even extremely resistant bacteria are safely destroyed in your

More information

Bacteria Control Troubleshooting Guide for Automated Watering Systems

Bacteria Control Troubleshooting Guide for Automated Watering Systems Revised 11/03 Bacteria Control Troubleshooting Guide for Automated Watering Systems Edstrom Industries www.edstrom.com 819 Bakke Ave. Waterford, Wisconsin 53185 4230-MI4169 Copyright 2003 Edstrom Industries,

More information

By: Curt Roth Vice President, Engineering EconoPure Water Systems, LLC. Point of Use/Point of Entry Treatment with LFNano. An EconoPure White Paper

By: Curt Roth Vice President, Engineering EconoPure Water Systems, LLC. Point of Use/Point of Entry Treatment with LFNano. An EconoPure White Paper An EconoPure White Paper 2024 N. Broadway Santa Ana, CA 92706 USA 1+(714) 258 8559 www.econopure.com Point of Use/Point of Entry Treatment with LFNano By: Curt Roth Vice President, Engineering EconoPure

More information

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS FILTRATION SOLUTIONS Pharmaceutical Manufacturing filtration specialists Delivering quality filtration products As one of Europe s leading manufacturers of process filters, Amazon Filters is able to offer

More information

Nine Industrial Scale V SEPs. Feed Tank V SEP. Feed Pumps (Three) Concentrate. Tank. V SEP Treatment System

Nine Industrial Scale V SEPs. Feed Tank V SEP. Feed Pumps (Three) Concentrate. Tank. V SEP Treatment System River Treatment for Ultrapure Production A cost-effective and environmentally-sound solution Abstract New Logic International installed its Vibratory Shear Enhanced Processing (VSEP) Phase I system in

More information

ETV Joint Verification Statement

ETV Joint Verification Statement THE ENVIRONMENTAL TECHNOLOGY VERIFICATION PROGRAM U.S. Environmental Protection Agency ETV Joint Verification Statement TECHNOLOGY TYPE: Continuous Emission Monitor APPLICATION: TECHNOLOGY NAME: COMPANY:

More information

Haemodialysis. Dialysers and Filters Product Range

Haemodialysis. Dialysers and Filters Product Range Haemodialysis Dialysers and Filters Product Range Contents Cardioprotective Haemodialysis Cardioprotective Haemodialysis 2 Fresenius Polysulfone and 3 Helixone Dialysis Membranes Dialysers and Haemofilters

More information

Laboratory Gas Generators. LABGAS Pure & Simple

Laboratory Gas Generators. LABGAS Pure & Simple Laboratory Gas Generators LABGAS Pure & Simple Don t Buy Gas, Make It! Generate laboratory gases for all of your analytical applications. PAYBACK IN LESS THAN 1 YEAR Hydrogen Eliminate high pressure cylinders

More information

Commercial Gas Water Heaters

Commercial Gas Water Heaters CYCLONE Mxi MODULATING MODULATING BURNER ADVANCES THE CYCLONE TO HIGHER LEVELS OF EFFICIENCY The full line of A. O. Smith Cyclone Mxi condensing water heaters has been designed to provide years of dependable

More information

Titration. Lecture # 8. Titrations in Analytical Chemistry. Other Forms of Titration. End Point vs. Equivalence Point. Minimizing Titration Error

Titration. Lecture # 8. Titrations in Analytical Chemistry. Other Forms of Titration. End Point vs. Equivalence Point. Minimizing Titration Error Lecture # MnO 5 H C O H CO Mn H O (purple) (colorless) (colorless) (colorless) Volumetric Analysis 0 ml s in Analytical Chemistry 11 Gravimetric Analysis Other Forms of End Point vs. Equivalence Point

More information

GC-xt. The most flexible GC /GC-MS liquid sample injector

GC-xt. The most flexible GC /GC-MS liquid sample injector GC-xt Prep and Load Platform The most flexible GC /GC-MS liquid sample injector Environmental Foods/Beverages Consumer Products Forensics Petrochemicals/Polymers Pharmaceuticals GC-xt Liquid mode Prep

More information

Laminar Flow Cabinets and Workstations

Laminar Flow Cabinets and Workstations VERTICAL AND HORIZONTAL HEPA FILTERED SYSTEMS FOR PROCESS OR OPERATOR PROTECTION Laminar Flow Cabinets and Workstations For procedures requiring protection from particulate contamination and for aseptic

More information

IUCLID 5 COMPOSITION AND ANALYSIS GUIDANCE DOCUMENT: IRON ORES, AGGLOMERATES [EINECS NUMBER 265 996 3, CAS NUMBER 65996 65 8] IRON ORE PELLETS

IUCLID 5 COMPOSITION AND ANALYSIS GUIDANCE DOCUMENT: IRON ORES, AGGLOMERATES [EINECS NUMBER 265 996 3, CAS NUMBER 65996 65 8] IRON ORE PELLETS IUCLID 5 COMPOSITION AND ANALYSIS GUIDANCE DOCUMENT: IRON ORES, AGGLOMERATES [EINECS NUMBER 265 996 3, CAS NUMBER 65996 65 8] IRON ORE PELLETS INTRODUCTION Each REACH registrant is required to file its

More information

Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES. FIMS 100 and 400. Flow Injection Mercury Systems

Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES. FIMS 100 and 400. Flow Injection Mercury Systems Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES FIMS 100 and 400 Flow Injection Mercury Systems Delivering the Performance You Need The determination and monitoring of sub-ppb concentrations

More information

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System TECHNICAL SPECIFICATION StirLIN-1 Economy Liquid Nitrogen System Reference 80 8120_01 Issue Date August 1, 2015 1. INTRODUCTION Since more than sixty years Stirling Cryogenics has designed and manufactured

More information

HySTAT HYDROGEN GENERATORS

HySTAT HYDROGEN GENERATORS HySTAT HYDROGEN GENERATORS Hydrogen On-Site THE POWER OF EXPERTISE Hydrogenics has a long term tradition building high performance water electrolysers. Since its inception in 1948 (under the name Electrolyser

More information