RSS Series Wired Electronic Ballasts

Size: px
Start display at page:

Download "RSS Series Wired Electronic Ballasts"

Transcription

1

2 RSS Series Wired s Specifications Charts RSS Series Electronic Sign Ballasts Minimum starting temperature is -20 F (-30 C). For use with T12 HO, T8 HO, and Slimline 120 Volts, 50/60Hz RSS Installation Wiring Diagrams* DIAGRAM 1 DIAGRAM 2 DIAGRAM 3 For 800mA T12/HO Standard No. of Wiring Diagram 1 to 2 4' 16' RSS296AT* 120V ,2 2 to 4 8' 32' RSS496AT** 120V to 6 24' 48' RSS696AT*** 120V Lamp Combination 2-Lamp Combination 2-Lamp Combination /White No. of RSS Ballast Chart For 800mA T8/HO Standard *For use with 1 10 lamp. **For use with 2 10 lamps. ***For use with 4 10 lamps. Wiring Diagram 1 to 2 4' 12' RSS296AT 120V ,2 2 to 4 8' 24' RSS496AT 120V to 6 18' 36' RSS696AT 120V DIAGRAM 4 3-Lamp Combination /White 4-Lamp Combination /White /White DIAGRAM 5 DIAGRAM 6 4-Lamp Combination CAT# T8/T12 # of lamps RSS296AT T8 1-2 T Total Lamp Range (Feet) RSS296AT (T8) RSS296AT (T12) RSS496AT T8 2-4 T RSS496AT (T8) RSS496AT (T12) RSS696AT T8 4-6 T RSS696AT (T8) RSS696AT (T12) Dimensions and Weights DIAGRAM 7 DIAGRAM 8 CAT # Lead Length (Feet) Dimensions (inches) Black White Length Width Height Weight (lb) RSS296AT /4 3-3/ / RSS496AT /16 3-3/16 2-5/ RSS696AT /2 3-3/16 2-5/ /White 5-Lamp Combination /White 6-Lamp Combination L Lamp 5 Side View H Top View Lamp 5 Lamp 6 2 *RSS Diagrams above can easily be used in both new installation and magnetic to electronic replacement applications. All ballasts must be grounded. 3

3 EESB Parallel Wired s Specifications Charts EESB Series Electronic Sign Ballasts Minimum starting temperature is -20 F (-30 C). For use with T12 HO, T8 HO, and Slimline 120 Volts, 50/60Hz No. of For 800mA T12/HO Standard Wiring Diagram 1 18" 8' EESB L 120V ,7 1 to 3 4' 24' EESB L 120V ,9 1 to 6 8' 32' EESB L 120V ,10 1 to 4 10' 40' EESB L * 120V ,11 2 to 6 10' 48' EESB L*** 120V ,12 For use with T12 HO, T8 HO, and Slimline 120/220/240/277 Volts, 50/60Hz No. of 1 to 4 1 to 2 2' 16' 4' 32' 1 to 6 2' 50' 2 to 6 10' 48' For 800mA T12/HO Standard 120V EESB-021L V 208V V V V EESB L V 208V V V V EESB L V** 208V V V V EESB L V* 208V V V Wiring Diagram For use with T12 HO, T8 HO, T8 18K hours Medium Life, and Slimline 120/220/240/277 Volts 50/60/Hz No. Of 1 to 2 2' 12' For 375mA T8 HO Medium Life 120V EESB-021L V 208V V V V EESB L V 208V V V V EESB L V 208V V V V V V V Wiring Diagram 1 to 4 4' 24' to 6 2' 48' 2 to 6 10' 48' *For use with up to 4 10 lamps **For use with up to 5 10 lamps ***DO NOT use 10 lamps EESB L V* 2-8 For use with T12 HO, T8 HO, T8 50K hours Long Life, and Slimline 120/220/240/277 Volts 50/60/Hz No. Of 1 to 6 2' 48' For 315mA T8 Long Life Lamp Wiring Diagram 120V V EESB L V 240V V

4 EESB Parallel Wired s EESB Ballast Chart EESB New Installation Wiring Diagrams CAT # T8/T12 # of lamps EESB L T8 1 T Total Lamp Range (Feet) EESB L (T8) EESB L (T12) DIAGRAM 1 DIAGRAM 2 DIAGRAM 3 EESB L T8 1-3 T EESB L (T8) EESB L (T12) EESB L T8 1-6 T EESB L (T8) EESB L (T12) EESB L T8 1-4 T EESB L (T8) EESB L (T12) EESB L T8 2-6 T EESB L (T8) EESB L (T12) EESB-021L V T8 1-2 T EESB-021L V (T8) EESB-021L V (T12) DIAGRAM 7 DIAGRAM 8 DIAGRAM 9 EESB L V T8 1-4 T EESB L V (T8) EESB L V (T12) EESB L V T8 1-6 T T8 Long Life 1-6 EESB L V (T8) EESB L V (T12) EESB L V (T8 Long Life) EESB L V T8 2-6 T EESB L V (T8) EESB l V (T12) Dimensions and Weights CAT # Lead Length (Feet) Dimensions (inches) Black White Length Width Height Weight (lb) EESB L /2 2-3/8 1-5/8 8-7/8 2 EESB L / /4 11-1/8 5 EESB L / /4 13-3/4 8 EESB L / /4 13-3/4 8 EESB L / /4 13-3/4 8 EESB-021L V /2 2-3/8 1-5/8 8-7/8 2.5 EESB L V / /4 13-3/4 9.5 EESB L V / /4 13-3/4 8 EESB L V / /4 13-3/4 9 DIAGRAM 4 DIAGRAM 5 DIAGRAM 6 DIAGRAM 10 DIAGRAM 11 DIAGRAM 12 * * L Side View H 6 Top View *Designed for use with lamps up to 10 in length. Wiring diagrams for Allanson Lighting Components' EESB s are simpler, with half the connections found in old-style magnetics. are parallel wired, so if one burns out the others keep working. All ballasts must be grounded. 7

5 EESB Parallel Wired s Fluorescent H.O. Lamp Holders EESB Magnetic to Electronic Re-Wiring Diagrams Tombstone Lamp Holders DIAGRAM 1 DIAGRAM 2 EESB- 021L (2-LAMP MAGNETIC TO ELECTRONIC) EESB L (3-LAMP MAGNETIC TO ELECTRONIC) White Black 2-Lamp White Black 3-Lamp /White /White DIAGRAM 3 DIAGRAM 4 Flush Mount Lamp Holders EESB L & EESB L (4-LAMP MAGNETIC TO ELECTRONIC) EESB L/ V, EESB L, & EESB L (6-LAMP MAGNETIC TO ELECTRONIC) 4-Lamp /white 6-Lamp Lamp 5 /White Lamp 6 Lamp holder Ratings: 660W, 600V / 1000V rating Symbol indicates to join two lamp socket wires together and then to connect to one wire (blue or red). Symbol indicates cutting of jumper wires to disconnect the parallel connection of lamp sockets. Materials: GE resins, Ni plated steels, stainless steels, O ring, and tin bronze contacts were used in the manufacturing of Allanson lamp holders. The 12 lead assemblies are stranded 18AWG tinned copper and have 1015/1032 UL ratings 221 F (105 C) and 1000V. For a live demonstration, watch our Magnetic to Electronic Replacement Video. : High strength metal retaining clips ensure solid hold when installed per specifications. D Hole: Visit culus listed. UL listed for use in U.S.A and Canada. 8 9

6 DOE Ballast Cross Reference Chart s Allanson Universal France Advance 148-AT DR 196-AT DR 224-AT DR AT DR ASB BL-TP 296-AT DR 348-AT DR 372-AT DR DR 396-AT DR 448-AT DR ASB BL-TP AT DR ASB BL-TP 496-AT DR ASB BL-TP 4120-AT DR ASB BL-TP 572-AT DR 648-AT DR 672-AT DR ASB BL-TP 696-AT KR ASB BL-TP Electronic Replacement Transco RSS EESB TRA ' - 4' RSS296AT EESB L / EESB-021L V " - 8' RSS296AT EESB L / EESB-021L V TRA " - 8" RSS296AT EESB-021L V --- 2' - 4' RSS296AT EESB-021L V TRA ' - 12' RSS296AT EESB L / EESB-021L V TRA ' - 16' RSS296AT EESB L / EESB-021L V TRA ' - 12' EESB L / EESB-021L V --- 6' - 12' EESB L / EESB-021L V TRA ' - 20' RSS496AT EESB L / EESB L V TRA ' - 24' RSS496AT EESB L / EESB L V TRA ' - 18' RSS496AT EESB L / EESB L V ' - 24' RSS496AT EESB L / EESB L V TRA ' - 24' RSS496AT EESB L / EESB L V TRA ' - 32' RSS496AT EESB L / EESB L V TRA ' - 40' RSS696AT EESB L / EESB L V ' - 30' RSS696AT EESB L / EESB L V TRA ' - 24' EESB L / EESB L V TRA ' - 36' RSS696AT EESB L / EESB L V TRA ' - 48' RSS696AT EESB L / EESB L V 148-AT-277V 168 KR 196-AT-277V 268 KR 272-AT-277V 268 KR 296-AT-277V 288 KR 348-AT-277V 348 KR 372-AT-277V 368 KR 396-AT-277V 388 KR 448-AT-277V 448 KR 472-AT-277V 468 KR 496-AT-277V KR 4120-AT-277V 4128 KR 572-AT-277V 568 KR 648-AT-277V 668 KR 672-AT-277V 668 KR 696-AT-277V 688 KR 2' - 4' --- EESB-021L V 18" - 8' --- EESB-021L V 4' - 12' --- EESB-021L V 12' - 16' --- EESB-021L V 6' - 12' --- EESB L V 6' - 12' --- EESB L V 18' - 24' --- EESB L V 8' - 18' --- EESB L V 16' - 24' --- EESB L V 24' - 32' --- EESB L V 20' - 40' --- EESB L V 20' - 30' --- EESB L V 8' - 24' --- EESB L V 24' - 36' --- EESB L V 30' - 48' --- EESB L V *EESB L V Ultimate Ballast Replaces all models

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement Flat Cable Connectors for PCBs XG2 Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring IDC connections allow you to wire all terminals at once without terminating the cable. Can

More information

12 Volt 30 Amp Digital Solar Charge Controller

12 Volt 30 Amp Digital Solar Charge Controller 12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

PROTECH ELECTRICAL CONNECTORS AND CABLE TIES

PROTECH ELECTRICAL CONNECTORS AND CABLE TIES INDEX ALLIGATOR CLIPS... 7-7 compressor lead sets... 7-7 CONNECTORS BUTT... 7-3 closed... 7-3 ELECTRICAL... 7-2 terminal adapters... 7-2 QUICK CONNECTS... 7-5 7-6 TWIST-ON WIRE... 7-2 HEAT SHRINK TUBING

More information

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] HARTING PushPull Connectors [on page 22] System cables [on page 24] Panel feed-throughs [on

More information

SECTION D LINEAR FLUORESCENT LAMPHOLDERS LINEAR FLUORESCENT LAMPHOLDERS

SECTION D LINEAR FLUORESCENT LAMPHOLDERS LINEAR FLUORESCENT LAMPHOLDERS 1850 Wilson Avenue, Toronto, Ontario, anada, M9M 1A1 Ph: 416-741-7336 Fax: 416-741-9104 SETION D LINEAR FLUORESENT LAMPHOLDERS D1 LINEAR FLUORESENT LAMPHOLDERS Linear Lamp Shadesand Bases T5 (G5) Miniature

More information

AMP Standard Terminals and Splices. RoHS. Ready

AMP Standard Terminals and Splices. RoHS. Ready AMP Standard Terminals and Splices RoHS Ready Table of Contents Product Facts Solderless terminals and splices performs up to today s standards for reliable termination in applications ranging from control

More information

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin

More information

GRX-PWM Pulse Width Modulation Interface

GRX-PWM Pulse Width Modulation Interface Pulse Width Modulation Interface pwm1 05.30.06 COOPERSBURG, PA 18036 U.S.A. Coopersburg, G 8 BR PA 18036 U.S.A. 144317 GRXTVI 19 P10 CB 0791275 Ratings Load T ype Switched Lowvoltage Load Type Switched

More information

Directory chapter 04

Directory chapter 04 M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

LED-INTA-0024V-41-F-O

LED-INTA-0024V-41-F-O Electrical Specifications LED-INTA-0024V-41-F-O Output Power (W) Output Voltage (V) Output Current (A) Tcase Max Input Current (A) Max. Input Power (W) Inrush Current (A pk /µs) Max. THD (%) Min. Power

More information

Furniture Fittings Furniture Handles and Knobs

Furniture Fittings Furniture Handles and Knobs Handle profile - Aluminium 21 mm 1.5 mm 2,500 mm 126.21.02 30 mm 126.22.0 11.5 mm 1.5 mm 2,500 mm 126.20.05 AH.4 Dim. A Dim. B Length Usable length Cat. No. 34.5 mm 8.5 mm 2,500 mm 2,460 mm 126.15.00 Dim.

More information

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD. 2108 LOW VOLTAGE TRACK LIGHTING SYSTEM

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD. 2108 LOW VOLTAGE TRACK LIGHTING SYSTEM 7/00 INSTALLATION INSTRUCTION SPEC. SHEET 99052 99063 City of New York Calendar #40747 Copyright c 2000 ALFA Lighting, Inc. All rights reserved. Call:1-415-975-8080 QUICK JACK QJS R LISTED 9901483 ETL

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations. DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,

More information

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY! READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY! The main power to any existing system must be disconnected prior to the

More information

Voltage Loss Formula s

Voltage Loss Formula s www.litz-wire.com HM Wire International Inc. Phone: 330-244-8501 Fax: 330-244-8561 Voltage Loss Formula s www.hmwire.com Voltage loss in a wire is synonymous to pressure loss in a pipe. Electric current

More information

Operation Manual. Trans-Flo

Operation Manual. Trans-Flo Operation Manual Trans-Flo The TRANS-FLO SYSTEM is a standard-output ballast that can be dimmed on most common theatrical SCR dimming systems. The modular design of the TRANS-FLO SYSTEM streamlines set

More information

D7 Series Standard and Full Featured. Standard DPDT 24V AC 120V AC 240V AC 12V DC 24V DC 120V AC 110V DC 240V AC 6V AC 6V DC 12V AC 12V DC 24V AC

D7 Series Standard and Full Featured. Standard DPDT 24V AC 120V AC 240V AC 12V DC 24V DC 120V AC 110V DC 240V AC 6V AC 6V DC 12V AC 12V DC 24V AC April 00 D Series Standard and Full Featured - Catalogue Number Structure Table -. D Series Catalogue Numbering System Family Type DPR = Standard Relay DPF = Full Featured Relay Contact Configuration =

More information

IRRIGATION PUMPING Table of Contents - Section 900

IRRIGATION PUMPING Table of Contents - Section 900 IRRIGATION PUMPING Table of Contents - Section 900 PARAGRAPH 900.1 GENERAL 1 900.2 METERING REQUIREMENTS 1 900.3 CUSTOMER S CONTROL EQUIPMENT 2 900.4 SERVICE CONDUCTOR REQUIREMENTS 2 900.5 RECOMMENDATIONS

More information

SlimSeal SSL Connector. Now Available in 1 Position. Free Hanging Version

SlimSeal SSL Connector. Now Available in 1 Position. Free Hanging Version Now Available in 1 Position Free Hanging Version SlimSeal SSL Connector The SlimSeal SSL connectors are low profile, single row connectors developed for indoor and outdoor LED lighting applications. These

More information

Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4.

Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4. Category 6 Solutions Introduction... 4.2 Cable... 4.3 Patch Panels... 4.4 Modules... 4.6 Patch Cords... 4.12 Outlets... 4.16 Faceplates...4.18 4. 1 Search Category 6 Solutions Introduction ADC KRONE s

More information

Shunt lock function 3066

Shunt lock function 3066 Version: January 2004 Contents Alarm System Activation unit Deactivation unit Digital locking cylinder or Smart Relay 1.0 Method of Operation 4 1.1 General 4 1.2 Turning the Alarm System On 4 1.3 Turning

More information

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V) FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V) 21T, Rev.4 6-13 IMPORTANT: Before proceeding, retrieve the GLASS SHADE INSTALLATION GUIDE, which is included with the pendant cord set

More information

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80 Buck-Boost Transformers Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...

More information

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short

More information

HARTING Ethernet Cabling 8-poles Overview

HARTING Ethernet Cabling 8-poles Overview Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs

More information

This product can be assembled to the baseplate maintaining 5 mm center-to-center spacing. Thus any number of poles can end-to-end stack.

This product can be assembled to the baseplate maintaining 5 mm center-to-center spacing. Thus any number of poles can end-to-end stack. page 1/5 Plug-in Screw Connector System for Printed Circuit Boards 950-NLFL-DS 5.00 mm (0.197 in) Spacing - 2-12 poles PICTURES 950-NLFL-DS 950-NLFL & 971-SLK TECHNICAL INFORMATION Description This two

More information

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET: SWITCH The Budderfly lighting switch is a Decora style, plug-and-play replacement for your existing building switches. Installing a Budderfly adapter transforms your building s existing wiring into the

More information

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview Ethernet Cabling 4-poles Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] Connectors [on page 22] System cables [on page 24] Panel feed-throughs

More information

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to

More information

STANDARD MICRO-D CONNECTORS

STANDARD MICRO-D CONNECTORS STANDARD MICRO-D CONNECTORS RECTANGULAR CONNECTORS Pigtail connector - Metal shell.............................. 56 Pigtail connector - Low profile - Metal shell.................... 58 Pigtail connector

More information

ISL-540 TBTS SERIES D EMERGENCY LIGHTING EQUIPMENT

ISL-540 TBTS SERIES D EMERGENCY LIGHTING EQUIPMENT P.O. BOX 11846 TUCSON, AZ 85734 (520) 294-3292 FAX (520) 741-2837 www.iotaengineering.com INSTRUCTION MANUAL IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always

More information

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording Hardware & Installation Guide Algo Communication Products Ltd. Customer Support and Sales Tel: 1.877.884.2546 Fax: 604.437.5726 Email: sales@algosolutions.com support@algosolutions.com www.algosolutions.com

More information

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8 System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures

More information

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &

More information

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050 Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage

More information

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions Disabled Toilet Alarm Installation & Operating Contractor Pack Installation & Operating Instructions 1 Overview The Channel Safety Systems Disabled Toilet alarm contractor Packs are an efficient way of

More information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

Industrial Ringdown/Autodialer Telephone SCR Series

Industrial Ringdown/Autodialer Telephone SCR Series Industrial Communications Worldwide Industrial Ringdown/Autodialer Telephone Installation & Operation SCR 11 SCR 41 P005603 Rev. A 060612 5/28/2007 3:58 PM 7552-10th Street N.E. Calgary, Alberta, Canada

More information

AUTOMOTIVE LED LIGHT CATALOG

AUTOMOTIVE LED LIGHT CATALOG AUTOMOTIVE LED LIGHT CATALOG #74 Wedge Flat LED Light 44423 #74 (T5) Wedge Flat LED Light. 1 LED. Durable, shock and vibration proof, instant On/Off. Monochromatic (pure) color, low heat generation, virtually

More information

High Bay Occupancy Sensor Selection Guide

High Bay Occupancy Sensor Selection Guide High Bay Occupancy Sensor Selection Guide Make the most of your energy SM 1 2 Schneider Electric offers a vast array of lighting control sensors for HID and Fluorescent High Bay applications. HID High

More information

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting

More information

AZ420 MINIATURE GENERAL PURPOSE RELAY

AZ420 MINIATURE GENERAL PURPOSE RELAY MINIATURE GENERAL PURPOSE RELAY FEATURES Rugged construction for high reliability Life expectancy greater than 0 million operations DC coils to 11 V Power consumption as low as 2 mw per pole available

More information

12-Volt Negative Ground Installation Instructions

12-Volt Negative Ground Installation Instructions 12-Volt Negative Ground Installation Instructions For Part Number: 1141, 1164, 1165, 1181 CAUTION!!! Before installing, please read the following important information... 1. The Ignitor is designed for

More information

280+ Mortise Mounted Series Shear Locks Special Application Solution

280+ Mortise Mounted Series Shear Locks Special Application Solution 280+ Mortise Mounted Series Shear Locks Power Plus control module overcomes gaps of up to 1/4" Low Temperature Operation 280+ TRD Locknetics provides the industry s most complete selection of electromagnetic

More information

Fire Alarm System Plans Review Checklist Property location Date of Review

Fire Alarm System Plans Review Checklist Property location Date of Review Fire Alarm System Plans Review Checklist Property location Date of Review 1. Is application completed in entirety? 2. Are the plans review fee submitted with the application? 3. Does floor plan include

More information

Cable Tray Selection-

Cable Tray Selection- Cable Selection- For allowable cable types see the Appendix page A-9. The following guidelines are based on the 2002 National Electrical Code, Article 392. I) Number of Multiconductor Cables rated 2000

More information

Operating Instructions. Room temperature controller

Operating Instructions. Room temperature controller Operating Instructions 1. Area of application The room temperature controller is used to regulate the temperature in closed rooms such as flats, schools, function suites, workshops, etc. Safety instructions

More information

Distribution Dry Type Transformers

Distribution Dry Type Transformers 8 TRASFORMERS Distribution Dry Type Transformers Table (Contact Sales office for List Price) (commonly used) 1a. 115 C Rise F 1b. 80 C Rise B 4. Wall Brackets1 W 6. Low noise XdB below std. LX Type bg

More information

Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011

Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011 WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers Installation Guide February, 2011 Pace Scientific Inc www.pace-sci.com Tel: 704-799-0688 sales@pace-sci.com 1 Disclaimer The following warranty

More information

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits Trade of Electrician Standards Based Apprenticeship Three-phase Distribution Boards And Socket Circuits Phase 2 Module No. 2.3 Unit No. 2.3.2 COURSE NOTES Created by Charlie Walsh - Athlone TC Revision

More information

V94 BULK TAPE DEGAUSSER

V94 BULK TAPE DEGAUSSER TECHNICAL MANUAL Operating and Maintenance Instructions for V94 BULK TAPE DEGAUSSER V94 BULK TAPE DEGAUSSER TECHNICAL MANUAL Document No. M000208 Production Standard ZZ 009 415 WARNING To help minimise

More information

No Phone Line System. Quick Start Guide NPL II. 1.0 Installation

No Phone Line System. Quick Start Guide NPL II. 1.0 Installation Used in conjunction with EntraGuard Gold Telephone Entry Systems, the provides No Phone Line communication and door or gate control through existing building telephone lines without the need purchase phone

More information

ADC Structured Cabling Solutions

ADC Structured Cabling Solutions ADC Structured Cabling Solutions The highest performing cross-connect system in the world HighBand Wall Mount Patching Solution Reliable, secure and cost effective ADC s HighBand cross connect solution

More information

COAXICON Contacts. RF Coax Connectors. Product Facts

COAXICON Contacts. RF Coax Connectors. Product Facts COXICON Contacts Product Facts Tyco Electronics provides a variety of contacts for coaxial connectors Contacts are available in a range of sizes that may be used with the various types of coaxial cable

More information

LOADING DOCK EQUIPMENT. A. Section 03100 - Concrete Forms and Accessories: Placement of anchors into concrete.

LOADING DOCK EQUIPMENT. A. Section 03100 - Concrete Forms and Accessories: Placement of anchors into concrete. LOADING DOCK EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Loading dock equipment of the following types: 1. Dock lifts. 2. Control stations. 1.2 RELATED SECTIONS A. Section 03100 - Concrete Forms and

More information

Linkeo 19" freestanding cabinets

Linkeo 19 freestanding cabinets 87045 LIMOGES Cedex France Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Linkeo 19" freestanding cabinets Page 1. General characteristics....1 2. Range....2 3. Technical characteristics...3

More information

Tutorials Drawing a 555 timer circuit

Tutorials Drawing a 555 timer circuit Step 1 of 10: Introduction This tutorial shows you how to make an electronic circuit using Livewire and PCB Wizard 3. You should follow this tutorial to learn the basic skills you will need to use Livewire

More information

Type NT and Type ZWM Terminal Blocks

Type NT and Type ZWM Terminal Blocks Type NT and Type ZWM Terminal Blocks Side view of closed Sliding Link Block Sliding Link Block with white marker strip Unit-pole construction Sliding link to permit testing without disturbing wiring High

More information

Model 201 Wiegand Touchpad Reader Installation Guide

Model 201 Wiegand Touchpad Reader Installation Guide Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without

More information

Table of Contents. www.hunterfan.com. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Table of Contents. www.hunterfan.com. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing. www.hunterfan.com Table of Contents What to Expect with Your Installation 30 inches Hanging the Fan Wiring 8 Maintenance, Operation & Cleaning Light Kit 13??? 14 1 9 Troubleshooting 11 5 Blades Motor Housing

More information

Color Mark Sensor with Red or Green LED E3S-VS

Color Mark Sensor with Red or Green LED E3S-VS Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical

More information

No Phone Line II-48 System

No Phone Line II-48 System Used in conjunction with an EntraGuard Telephone Entry System, the -48 provides No Phone Line communication and door or gate control through existing building telephone lines without the need to purchase

More information

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle Scope This specification stipulates the minimum requirements for mechanically linked three-phase electronic sectionalizers, for use on outdoor medium voltage overhead lines of 15, 27, and 38 kv. Electronic

More information

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE SP4LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE INSTALLATION AND OPERATION MANUAL MASS NOTIFICATION SYSTEM Part Number: P84767 Rev. A Copyright 2006 Cooper Wheelock, Inc. All rights reserved.

More information

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24 1 X CURRENT TRANSFORMER MODEL 546 1.10" I.D. PAGE No 1-38 REV 15DEC00 TERMINAL OPTION LEAD WIRE OPTION 1.10 0 1.20 2.55 3.00 3.47 0.18 x 0.31 SLOT ( 2 PLACES) 8-32 BRASS STUD (2 PLACES) UL1015 #16 AWG LEAD

More information

INNOVATION SUPPORTED BY A TRULY SOLID INDUSTRIAL ORGANIZATION.

INNOVATION SUPPORTED BY A TRULY SOLID INDUSTRIAL ORGANIZATION. CONNECTORS 2014 INNOVATION SUPPORTED BY A TRULY SOLID INDUSTRIAL ORGANIZATION. Stelvio Kontek S.p.A. is one of the leading groups in the connectors market. With a solid background in the sector and having

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

Medical Lighting. XL4 Patient Light

Medical Lighting. XL4 Patient Light Medical Lighting XL4 Patient Light The XL4 is the new ergonomically designed, energy efficient patient light from EDL Lighting Limited. Its purpose is to cover a spectrum of applications within the Healthcare

More information

Carton - Straight Link Machine Chain (Order Unit is Feet )

Carton - Straight Link Machine Chain (Order Unit is Feet ) Straight Link Machine Individual chain links shown actual size in reference section page 44. Carton Uses: General utility; farm and animal Standard Material: Low carbon steel Standard Finish: Bright (BRT),

More information

Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications

Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications Industrial and transportation applications require robust connections with superior

More information

Circuits and the Flow of Electricity

Circuits and the Flow of Electricity Lesson Overview This lesson helps Girl Scouts learn about how electricity works within a simple circuit. Many vocabulary words must be introduced (located under things for the leader to know). This lesson

More information

Hand Crank Generator (9 May 05) Converting a Portable Cordless Drill to a Hand Crank DC Generator

Hand Crank Generator (9 May 05) Converting a Portable Cordless Drill to a Hand Crank DC Generator Converting a Portable Cordless Drill to a Hand Crank DC Generator The unit is light weight (2.5 lb), portable, low cost ($10-$20) and can be used to recharge single cell batteries at from 1-3.5 amps. It

More information

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS: RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS: Signed completed Electrical Permit application form. Minnesota law requires all electrical work is to be performed by licensed,

More information

Socket P2RF-05-S P2RF-08-S Clip & Release Lever R99-11 nameplate for MY

Socket P2RF-05-S P2RF-08-S Clip & Release Lever R99-11 nameplate for MY Screwless Clamp Terminal Socket Screwless clamping greatly contributes to reducing wiring time. No over or under tightening of cable connection so better contact reliability is achieved. Double wiring

More information

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,

More information

12V Dimmable Driver EL-TMDRVR

12V Dimmable Driver EL-TMDRVR Elemental LED, LLC website: elementalled.com 11 9 5 P a r k A v e., S u i t e 2 11 Emeryville, CA 94608 toll free 877.564.5051 fax 510.740.4457 12V Dimmable Driver EL-TMDRVR ETL Listed #4001928 CSA Listed

More information

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Lighting Packages. 230 VAC Fluorescent Enclosure Light: Spec-00581 H763.422.2211 763.422.2600 Electrical Lighting Packages Electrical Lighting Packages PANELITE Enclosure Lights Overview FEATURES Slim profile allows light to be tucked up out of the way for

More information

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 2-1 General Specifications...1 2-2 Electrical Specifications... 2 3. FRONT PANEL DESCRIPTION... 4 3-1

More information

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service

More information

How To Read A Pipe From A Sensor

How To Read A Pipe From A Sensor Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing

More information

TMS TANK MANAGEMENT SYSTEM

TMS TANK MANAGEMENT SYSTEM TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Electric Vacuum Pump Kit 28146 Thank you for choosing STAINLESS STEEL BRAKES CORPORATION for your braking needs. Pleases take the time to read and carefully follow these instructions

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

LED WALL WASHERS SPECIFICATIONS & INSTALLATION GUIDE

LED WALL WASHERS SPECIFICATIONS & INSTALLATION GUIDE LED WALL WASHERS SPECIFICATIONS & INSTALLATION GUIDE ContenTS: Brief specifications LED WALL WASHER WWF 12 48... 4 LED WALL WASHER WWB 14 36... 5 LED WALL WASHER WWS 16 12... 6 LED WALL WASHER WWS 32 24...

More information

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors The Quality Connection High Performance Cable Solutions for the World of Semiconductors 2 Total Flexibility for Applications with the Toughest Requirements LEONI is your long-term, reliable partner supplying

More information

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors The Quality Connection High Performance Cable Solutions for the World of Semiconductors 2 Total Flexibility for Applications with the Toughest Requirements LEONI is your long-term, reliable partner supplying

More information

Height w/o Terminals (in)

Height w/o Terminals (in) EaglePicher Technologies, LLC Commercial Power P.O. Box 47 Joplin, MO 6482 (417) 623-8 inquiry.carefree@eaglepicher.com Carefree Sealed Lead Acid (SLA) MSDS EaglePicher s Carefree lead acid batteries are

More information

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS RELATED SECTIONS: Section 27 00 00 General Requirements Section 27 02 00 Communication General Requirements Section 27 05 28 Pathways for Communications

More information

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector. Photoelectric Sensor with Built-in Amplifier Photoelectric Sensor with built-in amplifier is applicable to a wide variety of lines and ensures a longer sensing distance than any other model. User-friendly

More information

ELECTRONICS G H I J K L M

ELECTRONICS G H I J K L M ELECTRONICS TM LASER INSTALLATION INSTRUCTIONS PARTS KIT Parts Kit includes the following: A- (1) Universal Mounting Bracket A B- (1) Red L.E.D. Laser Alert Light C- (1) Piezo Beeper w/ O Ring Tape D-

More information

INSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range.

INSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range. ENGLISH ESPAÑOL INSTALLATION MANUAL ELECTRIC RANGE Please read these instructions thoroughly before installing and operating the range. LRE3025ST LRE3085ST LRE3083ST LRE3083SB LRE3083SW LRE3021ST LDE3037ST

More information

Invue ECM/EMM EPIC MEDIUM 42-150W

Invue ECM/EMM EPIC MEDIUM 42-150W DESCRIPTION The EPIC Collection delivers custom luminaire flexibility with the quality and availability expectations of standard specification grade product. Offered in two housing sizes and hundreds of

More information

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION GE Lighting Installation Instructions Lighting Controls Centralized Lighting Control Panel Interior Catalog Number CLCINTxx DESCRIPTION The Centralized Lighting Control System is a small network of relay

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

Product Line 016 2009 DUST. The family of hermetic luminaires

Product Line 016 2009 DUST. The family of hermetic luminaires Product Line 016 2009 DUST The family of hermetic luminaires DUST A luminaire for all conditions DUST is the family of hermetic luminaires that works best in spaces of high dustiness and humidity level

More information

LHD LINEAR HEAT D ETECTIONN

LHD LINEAR HEAT D ETECTIONN Tri-Metallic Core: Steel provides tensile strength Copper increase conductivity Tin for corrosion resistance LHD LINEAR HEAT D ETECTIONN TECHNICAL DATA Temperature Rating: 155 F (68 C) (typical temperature)

More information