Transmission Company Of Nigeria Project Management Unit. March, 2014
|
|
- Caroline Waters
- 7 years ago
- Views:
Transcription
1 Transmission Company Of Nigeria Management Unit Status Report on On-going s Presentation to The Honourable Minister Of State For Power Mohammed Wakili March, 2014 World Bank Intervention in Energy Sector in Nigeria
2 1 Rehabilitation & Reinforcement of 33/11KV Injection Substation: No. NGP-D1 Lot 1 Lot1A: Eko Lot Ikeja 1B 30/08/12 Amount $6,372, ,209, or MBH Power/ Shirdi Sai & Shreem Electric India JV 30/08/12 MBH Power/ Shirdi Sai & Shreem Electric India JV Installation of 1nos 15MVA Installation of 1set of 33KV Indoor breaker Installation of 40nos 500kVA s Installation of 80nos 11KV Feeder Pillar Installation of 80nos 11KV Drop Out Fuses Installation of 80nos 11KV Lighting Arresters Erection of 1000nos HT poles Erection of 1,100nos LT poles Stinging of 75km of AAC for HT and LT lines Installation of 1nos 15MVA Installation of 2set of 33KV breaker Installation of 2sets 33KV Gang Isolator Installation of 73nos 500kVA s Installation of 150nos 11KV Feeder Pillar Installation of 123nos 11KV Drop Out Fuses Installation of 123nos 11KV Lighting Arresters Erection of 1,100nos HT poles Erection of 1,500nos LT poles Stinging of 85km of AAC for HT and LT lines Status 1no 15MVA & 40no 500KVA 2,000meters 1Cx500mm2 cable 296,000meter All Aluminium Conductor awaiting custom clearance CT, VT and Circuit Breaker shipped 1no 15MVA & 40no 500KVA 3,760meter 1Cx500mm2 cable 374,000meter All Aluminium Conductor awaiting Custom clearance CT, VT and Circuit Breaker shipped
3 2 Rehabilitation & Reinforcement of 33/11KV Injection Substation: No. NGP-D1 Lot 2 Lot 2A: Ibadan 30/08/12 Amount $6,193, ,220, o r MBH Power/ Shirdi Sai & Shreem Electric India JV Installation of 1nos 15MVA Installation of 2set of 33KV Outdoor breaker Installation of 70nos 500kVA s Installation of 120nos 11KV Feeder Pillar Installation of 120nos 11KV Drop Out Fuses Installation of 120nos 11KV Lighting Arresters Erection of 1,000nos HT poles Erection of 900nos LT poles Stinging of 80km of AAC for HT and LT lines Status 1no 15MVA and 70no 500KVA 2,500meters 1Cx500mm2, cable 320,00meters All Aluminium Conductor CTs, VTs and Circuit Breaker shipped Lot 2B: Benin 30/08/12 MBH Power/ Shirdi Sai & Shreem Electric India JV Installation of 1nos 15MVA Installation of 2set of 33KV Outdoor breaker Installation of 2sets 33KV Gang Isolator Installation of 50nos 500kVA s Installation of 90nos 11KV Feeder Pillar Installation of 85nos 11KV Drop Out Fuses Installation of 85nos 11KV Lighting Arresters Erection of 1,000nos HT poles Erection of 850nos LT poles Stinging of 78km of AAC for HT and LT lines 1no 15MVA and 50no 500KVA 3,600meters 1Cx500mm2 cable 155,00meters All Aluminium Conductor CTs, VTs and Circuit Breaker shipped
4 3 Rehabilitation & Reinforcement of 33/11KV Injection Substation: No. NGP-D1 Lot 3 Lot 3A: Enugu 31/08/12 Amount $7,368, ,511, or News Engineerin g Ltd Installation of 1nos 15MVA Installation of 2set of 33KV breaker Installation of 70nos 500kVA s Installation of 150nos 11KV Feeder Pillar Installation of 120nos 11KV D/Out Fuses Installation of 120nos 11KV Lighting Arresters Erection of 1,000nos HT poles Erection of 1,500nos LT poles Stinging of 87km of AAC for HT & LT lines Status 15MVA & 500KVA s ready for FAT 3,600m 1Cx500mm2, 4,500m 4Cx150mm2, 3,150m 1Cx35mm2 cable and 360,000m of Aluminium conductor delivered to contractor wharehouse Circuit Breaker, CTs & VTs shipped Lot 3B: P/Harcour t 31/08/12 News Engineerin g Ltd Installation of 1nos 15MVA Installation of 2set of 33KV breaker Installation of 2sets 33KV Gang Isolator Installation of 50nos 500kVA s Installation of 110nos 11KV Feeder Pillar Installation of 100nos 11KV D/Out Fuses Installation of 100nos 11KV Lighting Arresters Erection of 1,000nos HT poles Erection of 900nos LT poles Stinging of 80km of AAC for HT & LT lines 15MVA and 500KVA s ready for FAT 3,090m 1Cx500mm2, 3,900m 4Cx150mm2, and 2,250m 1Cx35mm2 cable and and 360,000m of Aluminium conductor delivered to contractor wharehouse. Circuit Breaker, CTs & VTs shipped
5 4 Rehabilitation & Reinforcement of 33/11KV Injection Substation: No. NGP-D1 Lot 4 Lot 4A: Abuja Lot 4B: Jos 31/08/12 Amount $6,420, ,657, or Skipper Electrical Ltd India 31/08/12 Skipper Electrical Ltd India Installation of 1nos 15MVA Installation of 2set of 33KV Outdoor breaker Installation of 70nos 500kVA s Installation of 150nos 11KV Feeder Pillar Installation of 120nos 11KV Drop Out Fuses Installation of 120nos 11KV Lighting Arresters Erection of 1,650nos HT poles Erection of 1,200nos LT poles Stinging of 90km of AAC for HT and LT lines Installation of 1nos 15MVA Installation of 2set of 33KV Outdoor breaker Installation of 2sets 33KV Gang Isolator Installation of 70nos 500kVA s Installation of 150nos 11KV Feeder Pillar Installation of 120nos 11KV Drop Out Fuses Installation of 120nos 11KV Lighting Arresters Erection of 1,000nos HT poles Erection of 1,500nos LT poles Stinging of 93km of AAC for HT and LT lines Status 1no 15MVA and 30no 500KVA 150no feeder pillar, 120no lighting arresters 500No HT poles, 300 LT poles and and 380,000m All Aluminium Conductor Circuit breaker, CT and VT installed Erection and stringing in progress 1no 15MVA and 13no 500KVA, CT, VT and Circuit breaker 500No HT poles and 300 LT poles delivered to 150no feeder pillar, 120no lighting arresters and 380,000m All Aluminium Conductor cleared from port and delivered to Abuja
6 5 Rehabilitation & Reinforcement of 33/11KV Injection Substation: No. NGP-D1 Lot 5 Lot 5A: Kaduna Lot 5B: Kano 30/08/12 Amount $4,451, ,973, or Seacof Engineering Services/ Uktal galvanizers Ltd India JV 30/08/12 Seacof Engineering Services/ Uktal galvanizers Ltd India JV Installation of 1nos 15MVA Installation of 2set of 33KV Outdoor breaker Installation of 50nos 500kVA s Installation of 110nos 11KV Feeder Pillar Installation of 100nos 11KV Drop Out Fuses Installation of 100nos 11KV Lighting Arresters Erection of 1,850nos HT poles Erection of 1,000nos LT poles Stinging of 94km of AAC for HT and LT lines Installation of 1nos 15MVA Installation of 2set of 33KV Outdoor breaker Installation of 2sets 33KV Gang Isolator Installation of 70nos 500kVA s Installation of 150nos 11KV Feeder Pillar Installation of 120nos 11KV Drop Out Fuses Installation of 120nos 11KV Lighting Arresters Erection of 1,000nos HT poles Erection of 1,500nos LT poles Stinging of 93km of AAC for HT and LT lines Status 700No HT poles 2,500no Pin insulators and 400no crossarms delivered to Conductors, Cables & insulators awaiting clearance at the port 15MVA & 500KVA s shipment process in progress 400No HT poles 1,000no Pin insulators & crossarms 300no Conductors, Cables & insulators awaiting clearance at the port 15MVA & 500KVA s shipment process in progress
7 6 Rehabilitation & Reinforcement of 33/11KV Injection Substation: No. NGP- D1 Lot 6 Lot 6A: Yola Amount or 30/08/12 $2,692, Seacof Engineering Services/ Uktal galvanizers Ltd India JV Installation of 1nos 15MVA Installation of 2set of 33KV Outdoor breaker Installation of 40nos 500kVA s Installation of 80nos 11KV Feeder Pillar Installation of 80nos 11KV Drop Out Fuses Installation of 80nos 11KV Lighting Arresters Erection of 1,000nos HT poles Erection of 1,100nos LT poles Stinging of 94km of AAC for HT and LT lines Status 1no 15MVA 1,500meters 1Cx500mm2 cable delivered to 2,000meters 4cx150mm2 cable delivered to 365,000meter All Aluminium Conductor Sectionalizers Pole erection on going 7 Supply & Installation of 300no 11KV Onload sectionalisers at Karu, Luth, Ogba, Agege & Chanllenge No NGP- D2 Abuja, Ibadan, Ikeja, & Eko 30/11/11 $456, ,200, Crown Resources Development Ltd Installation of 60No. 11KV Onload sectionalisers in Karu, Abuja Installation of 50No. 11KV Onload sectionalisers in LUTH, Lagos Installation of 70No. 11KV Onload sectionalisers in Ogba, Lagos Installation of 90No. 11KV Onload sectionalisers in Agege Installation of 30No. 11KV Onload sectionalisers in challenge, Ibadan
8 8 Rehabilitation of 33KV Switchgears in Eko Electricity Distribution Company No. NGP- D3 Lot 1 Lot 1: Lagos Amount or 02/07/11 $2,692, ABB Nigeria Ltd Rehabilitation of 33kV indoor switchgears (GIS) complete at 7No Injection Substations in Eko Disco Status Rehabilitation 33KV Indoor switchgears completed and awaiting commissioning 9 Rehabilitation of 33KV Underground cable In Eko Electricity Distribution Company No. NGP- D3 Lot 2 Lot 2: Lagos 21/07/11 $456, ,200, Seacof Engineering Services Ltd Rehabilitation of 12no 33KV Underground Feeders in Eko Discos Rehabilitation of the 33KV Underground cable feeder Completed and ready for commissioning
9 10 Conversion of LVDS to HVDS in Kano No. NGP-D4 Lot 1 Amount Kano 13/02/13 $83, ,783, or Seacof Engineering Services Installation of 560no 50KVA Installation of 300no 25KVA Installation of 500no 11KV Drop Out Fuses Installation of 430no 11KV Triple pole Air Break Switches Installation of 1,000no LV distribution Boxes. Erection of 1,973no HT poles Stringing of 37Km AAC HT & LT lines Status 860no 50KVA/25KVA s 11KV 500no Drop Out Fuses 11KV 430no Triple pole Air Break Switches delivered to 1,000no LV distribution Boxes 1,500no HT poles delivered to Pole erection is on-going 11 Conversion of LVDS to HVDS in Kaduna No. NGP-D4 Lot 2 Kaduna 08/02/13 $439,873, ,870, News Engineering Nigeria Ltd Installation of 560no 50KVA Installation of 300no 25KVA Installation of 500no 11KV Drop Out Fuses Installation of 430no 11KV Triple pole Air Break Switches Installation of 1,000no LV distribution Boxes. Erection of 1,712no HT poles Stringing of 35Km AAC HT & LT lines 860no 50KVA/25KVA s 11KV 500no Drop Out Fuses 11KV 430no Triple pole Air Break Switches delivered to 1,000no LV distribution Boxes 1,200no HT poles delivered to Pole erection is on-going
10 12 Conversion of LVDS to HVDS in Benin No. NGP-D4 Lot 3 Amount Benin 13/02/13 $83, ,519, or Seacof Engineering Services Installation of 560no 50KVA Installation of 300no 25KVA Installation of 500no 11KV Drop Out Fuses Installation of 430no 11KV Triple pole Air Break Switches Installation of 1,000no LV distribution Boxes. Erection of 1,676no HT poles Stringing of 35Km AAC HT & LT lines Status 860no 50KVA/25KVA s 11KV 500no Drop Out Fuses 11KV 430no Triple pole Air Break Switches delivered to 1,000no LV distribution Boxes 1,200no HT poles delivered to Pole erection is on-going 13 Conversion of LVDS to HVDS in Enugu No. NGP-D4 Lot 4 Enugu 18/02/13 $570, ,437, East India Udyog Ltd Installation of 560no 50KVA Installation of 300no 25KVA Installation of 500no 11KV Drop Out Fuses Installation of 430no 11KV Triple pole Air Break Switches Installation of 1,000no LV distribution Boxes. Erection of 2,220no HT poles Stringing of 40Km AAC HT & LT lines 860no 50KVA/25KVA s 11KV 500no Drop Out Fuses 11KV 430no Triple pole Air Break Switches delivered to 1,000no LV distribution Boxes 1,200no HT poles delivered to
11 14 Conversion of LVDS to HVDS in P/Harcourt No. NGP-D4 Lot 5 Amount P/Harcourt 13/02/13 $603, ,888, or East India Udyog Ltd Installation of 560no 50KVA Installation of 300no 25KVA Installation of 500no 11KV Drop Out Fuses Installation of 430no 11KV Triple pole Air Break Switches Installation of 1,000no LV distribution Boxes. Erection of 2,432no HT poles Stringing of 40Km AAC HT & LT lines Status 860no 50KVA/25KVA s 11KV 500no Drop Out Fuses 11KV 430no Triple pole Air Break Switches delivered to 1,000no LV distribution Boxes 1,200no HT poles delivered to 15 Electrification of Rural Communities in Enugu State. No. D2-D6 Lot 1 Enugu 18/02/13 $861, , 120, East India Udyog Ltd Installation of 28no 25kVA, 101no 50kVA, 2no 200KVA, 1no 500KVA, 1no 300KVA 33/0.415kV Distribution Transformers. Stringing of 33KV overhead lines and Connection and Metering of 3,000 customers within the Communities All the s in the contract 89no s mounted on poles 425no HT poles erected and still on-going
12 16 Electrification of Rural Communities in Ogun State. No. D2-D6 Lot 2 Amount Ogun 18/02/13 $1,153, , 084, or East India Udyog Ltd Installation of 40no 25kVA and 70no 50kVA 33/0.415kV Distribution Transformers. Stringing of 33KV overhead lines and Connection and Metering of 3,000 customers within the Communities Status 69no s delivered to 425no HT poles erected and still on-going 17 Electrification of Rural Communities in Cross River State. No. D2-D6 Lot 3a Obalinku 31/01/13 $203, , 556, Crown Resources Dev. Ltd Installation of 18no 25kVA and 44no 50kVA 33/0.415kV Distribution Transformers. Stringing of 33KV overhead lines, Connection and Metering of 1,900 customers within the Communities completed and awaiting commissioning. 18 Electrification of Rural Communities in Cross River State. No. D2-D6 Lot 3b Ogoja 31/01/13 $259, , 503, Crown Resources Dev. Ltd Installation of 14no 25kVA and 45no 50kVA 33/0.415kV Distribution Transformers. Stringing of 33KV overhead lines, Connection and Metering of 1,800 customers within the Communities 700nos of HT and 110nos of LT poles erected and stringed. Installation of s is on-going
13 19 Conversion of LVDS to HVDS in Kubwa. No. D2-E lot 3 Kubwa- Abuja Amount 21/05/2013 $5,385, ,841, or Goodluck Steel Tubes/Voltect PVT Ltd, India Installation of 915no 50kVA 11/0.415kV Distribution Transformers. Stringing of 33KV overhead lines, Connection of 9,150 customers within the Kubwa Status 544no 50kVA 11/0.415kV Distribution Transformers 20 Supply and Installation of Prepayment meters in Kaduna State. No. NGP- D5 Kaduna 19/11/13 $203, , 556, Shenzien Inhmeter Co. Ltd/Triplesea Ltd Supply and Installation of 40,000no of Pre Payment meters Signed and Kick-off meeting held. 10% advance payment paid
14 ON-GOING TRANSMISSION CONTRACTS under NEGIP 1 Rehabilitation & Reinforcement of Transmission Substations No. NGP-T1 Lot 1 Lot1: Afam I, Afam IV, Port Harcourt, Aba Town, Eket Amount 22/06/12 $7,785, ,923, or GIT/XIAN Electric Engineering Ltd Installation of 1nos 60MVA at Afam I 132/33KV Transmission Substation Rehabilitation of Afam IV 330/132KV Transmission Substation Rehabilitation of Port Harcourt 330/132KV Transmission Substation Installation of 1nos 60MVA at Aba Town 132/33KV Transmission Substation Installation of 1nos 60MVA at Eket 132/33KV Transmission Substation Status Technical specification for 60MVA approved 2 Rehabilitation & Reinforcement of Transmission Substations No. NGP-T1 Lot 2 Lot 2: Akangba, Ikeja West, Ikorodu, Akangba 22/06/12 $12,718, ,641, MBH Power/ Shreem Electric Ltd Rehabilitation of Akangba 330/132KV Transmission Substation Rehabilitation of Ikeja West 330/132KV Transmission Substation Installation of 1nos 60MVA at Ikorodu 132/33KV Transmission Substation Installation of 2nos 60MVA at Akangba 132/33KV Transmission Substation Technical specification for 60MVA, 33kV and 132kV circuit breakers approved
15 ON-GOING TRANSMISSION CONTRACTS under NEGIP 3 Rehabilitation & Reinforcement of Transmission Substations No. NGP-T1 Lot 3 4 Rehabilitation & Reinforcement of Transmission Substations: No. NGP- T1 Lot 4 Lot 3: Osogbo, Ayede, Ijebu Ode Lot 4: Kaduna (Mando), Kano (Dan Agundi) Amount 22/06/12 $8,922, ,542, /06/12 $7,733, ,314, or Fedders Llyod Corporation Fedders Llyod Corporation Installation of 1nos 60MVA at Osogbo 132/33KV Transmission Substation Installation of 1nos 60MVA at Ayede 132/33KV Transmission Substation Rehabilitation of Ayede 330/132KV Transmission Substation Installation of 1nos 60MVA at Ijebu Ode 132/33KV Transmission Substation Installation of 1nos 60MVA at Kaduna (Mando) 132/33KV Transmission Substation Installation of 1nos 60MVA at Kano (Dan Agundi) 132/33KV Transmission Substation Status 3No 60MVA, s delivered to 3Nos Earthing. 25No Circuit Breaker CT and VT awaiting clearance at Apapa port 2No 60MVA, s delivered to 2No Earthing. 39No CTs and 27No VTs 25No Circuit Breaker and 52No Isolators delivered to 5Nos 330KV Circuit breaker, Illumination materials, Conductors shipped.
16 ON-GOING TRANSMISSION CONTRACTS under NEGIP Amount or Status 5 Civil Reconstruction and Flood Control of sinking Alagbon 132kV Substation Alagbon- Lago 12/04/13 695,384, Bussdor and Company Ltd Flood Control of Alagbon 132/33KKV Substation 75% of the material on
17 ON-GOING GENERATION CONTRACTS under WRDSEM 1 Rehabilitation of Kainji Hydroelectric Power Plant (Units 5, 6 & 12) and the Common Systems. No. KR1A Amount or Kainji 27/06/11 $81,746, Hydrochina Huadong/ Harbin Electric Machinery Company Consortium Rehabilitation of units 5,6, and 12 of the Hydroelectric power plant Status Unit 5: All the parts have been dismantled and overhauling of the unit is on-going. Rehabilitation of intake gate 80% completed Unit 6 : All the parts have been dismantled and overhauling of the unit is on-going. Unit 12 : All the parts have been dismantled and overhauling of the unit is ongoing. To be commissioned in April, Rehabilitation of Jebba Spillway Discharege Channel, Grouting of Auxillary Dam 3 Jebba 27/11/12 2,277,000, Ceinsa Consortium Rehabilitation of Spillway Discharge Channel. 40% of work completed. Construction of the Coffer-dam in process. To be completed in April, 2014: Protective wall A &C are 90% & 97% Completed Rehabilitation of well 53 of the auxiliary dam completed. Rehabilitation of spillway discharge channel is 82% completed
18 CONTRACT UNDER BIDDING PROCESS or Status 1 Construction, Rehabilitation and Reinforcement 330/132KV Transmission substation No. NGP-T4 N/A Under Bidding Process
19 THANK YOU ALL FOR YOUR ATTENTION!!! STAY CONNECTED.. ENGR. CIROMA.A. JOSEPH, FNSE MIAD, FCAI, MNIMC, MNISP GENERAL MANAGER TRANSMISSION COMPANY OF NIGERIA PLC PROJECT MANAGEMENT UNIT NO. 7 KAMPALA STREET, WUSE II ABUJA - NIGERIA ciromaddd@yahoo.co.uk jciroma@gmail.com,jciroma@nepapmu.org.ng
Electricity Distribution Engineering and Geographic Information System (DeGIS).
Electricity Distribution Engineering and Geographic Information System (DeGIS). OLANIYI Saheed Salawudeen, Nigeria and USMAN Rashidat, Nigeria Key Words: GIS, Electricity Distribution, Geodatabase, Analysis,
More informationCITATION ON ENGR. MUSTAFA BALARABE SHEHU
CITATION ON ENGR. MUSTAFA BALARABE SHEHU Early Life and Studies Mustafa Balarabe Shehu was born on 12 th April 1963 to a Veterinary Officer Alhaji Shehu Salihu and Hajiya Rakiya, both of blessed memory.
More informationELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV
1. SCOPE This document details PowerSystems requirements for electrical testing of HV Equipment up to and including 33kV. 2. ISSUE RECORD This is a Reference document. The current version of Controlled
More informationOverview of the Nigerian Electricity Industry (Roles, Responsibilities,
Overview of the Nigerian Electricity Industry (Roles, Responsibilities, Structure, Expectation) Presentation at the Nigeria Power Sector Investment Forum - Lagos, Dubai, London, New York and Johannesburg
More informationINDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION
INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION February 2013 NOTE: If conflict exists between St. Thomas Energy s Conditions of Service and this document, the Conditions
More informationMedium Voltage (MV) & High Voltage (HV) Training Module 6. Date of the presentation
Medium Voltage (MV) & High Voltage (HV) Training Module 6 Date of the presentation Electrical System Basics MV vs. HV - Definitions Differences between USA and the rest of the world IEC define a high voltage
More informationBL20A0501 Electricity distribution technology. Introduction Jarmo Partanen
BL20A0501 Electricity distribution technology Introduction Jarmo Partanen Introduction to ED Prof. Jarmo Partanen, D.Sc Jukka Lassila Topics of lectures Introduction to Electricity Distribution, 27.10
More informationNigeria s Power Privatisation Process: Learning Curves. Chijioke Okonkwo Senior Consultant June 2015
Nigeria s Power Privatisation Process: Learning Curves Chijioke Okonkwo Senior Consultant June 2015 Learning Curves from Structure and Process Adopted for the PHCN Privatisation OUTLINE Introduction Review
More informationHyperlinks are Inactive
Prepared by: NIB/EOB PLANNING GUIDE FOR SINGLE CUSTOMER SUBSTATIONS SERVED FROM TRANSMISSION LINES 05503 Department: Electric T&D Section: T&D Engineering and Technical Support Approved by: G.O. Duru (GOD)
More informationTHE NIGERIAN ELECTRICITY SUPPLY INDUSTRY: STATUS, CHALLENGES AND SOME WAYS FORWARD. Engr. (Dr) Moses Amadasun MNSE, MIEEE
THE NIGERIAN ELECTRICITY SUPPLY INDUSTRY: STATUS, CHALLENGES AND SOME WAYS FORWARD Engr. (Dr) Moses Amadasun MNSE, MIEEE Abstract: The present capacity of the Nigerian Electricity Supply Industry to provide
More informationAsset Management Plans
November 213 Introduction Table of Contents Page # ACS Buildings & Grounds 2 Purpose and Scope ACS Buildings & Seismic 3 The purpose of these ( Plans ) is to demonstrate how we intend to deliver on the
More informationA. 5MWp SPV Plant at Khimsar, Rajasthan. B. 5MWp SPV Plant Installed Technologies. D. 5MWp SPV Plant Challenges. E. 5MWp SPV Plant - Performance
An overview & Performance Analysis of 5 MWp Solar PV Plant at Khimsar, Rj Rajasthan Reliance Industries Limited June 2, 2011 July 2010 Contents A. 5MWp SPV Plant at Khimsar, Rajasthan B. 5MWp SPV Plant
More informationFuture Role of Distribution Companies Deployment of Smart Systems. Dr. Sam Amadi Chairman/CEO
NIGERIAN ELECTRICITY REGULATORY COMMISSION Future Role of Distribution Companies Deployment of Smart Systems Dr. Sam Amadi Chairman/CEO 6 th World Forum on Energy Regulation Tuesday, May 26, 2015 Istanbul
More informationSecondly, those that are not on the grid yet, require that the grid be expanded to provide them with electricity services.
1 P a g e EXECUTIVE SUMMARY This white paper broadly explores customer relationship management (CRM) practices in the electricity distribution sector in Nigeria. It identifies some of the existing challenges
More informationABB Power Systems. Substations References
ABB Power Systems Substations References Jingzhou, China BA PTPS - 2 - Connection of power from the 3-Gorges-Project to Guandong province (940km away) HVDC Transmission station, Filter banks and GIS Extremely
More informationA BRIEF ON NAPTIN & THE HUMAN CAPACITY CHALLENGE IN THE POWER SECTOR. Engr. Reuben Okeke
A BRIEF ON NAPTIN & THE HUMAN CAPACITY CHALLENGE IN THE POWER SECTOR By Engr. Reuben Okeke Director General National Power Training Institute of Nigeria (NAPTIN) Outline Technical Manpower Gap in the Power
More informationIssues and Challenges in the Nigerian Electricity Industry: Case of Benin Electricity Distribution Company
Issues and Challenges in the Nigerian Electricity Industry: Case of Benin Electricity Distribution Company Roland Uhunmwagho Kenneth E. Okedu * Department of Electrical Engineering, College of Engineering,
More informationTakfan Machinery and Mould Co Ltd. Plug in Bushing. LV Monoblock. RMU Bushing. 4 Way CT Terminal. www.takfanmakina.com.tr
www.takfanmakina.com.tr Plug in Bushing LV Monoblock RMU Bushing 4 Way CT Terminal Solution Partner of Medium Voltage Insulation and Epoxy Casting Design *Medium voltage Switching Equipments Design *Load
More informationEmirates Aluminium starts up World s first fully integrated power distribution system from ABB
Reprint from Aluminium World 2009, Volume 2 Emirates Aluminium starts up World s first fully integrated power distribution system from ABB Emirates Aluminium (EMAL), a joint venture between Abu Dhabi s
More informationCertificate of Registration
Certificate of Registration This is to certify that Clancy Docwra Limited Supplier Number: 061973 are now fully registered as a supplier on UVDB for the following products/services 1.4.25 Communication
More informationHow To Choose A Transformer
Consider open loop MV network as an example source 1 source 2 NC NC NC or NO main MV switchboard A B Detail design of substation NC NC NC NO NC NC switchboard 1 switchboard 2 switchboard 3 MV MV MV LV
More informationTHE PRESIDENCY, BUREAU OF PUBLIC ENTERPRISES
THE PRESIDENCY, BUREAU OF PUBLIC ENTERPRISES POWER PRIVATIZATION:OBJECTIVES, CURRENT STATUS, PROSPECTS & CHALLENGES By Ibrahim Baba Gana Ag Director (Electric Power) BPE A Presentation to the Breakfast
More informationPower transformers. Special transformers Railway
Power transformers Special transformers Railway A leader in railway systems Our compact and low-weight transformers fully comply with the customer s specifications. The products are developed together
More informationDistribution Substation Manual (DSM) Section 3 Substation Arrangements
(DSM) Section 3 Substation Arrangements July 2015 Document release information Client Project name Western Power Distribution Substation Manual Document number 5 Document title Revision status Substation
More informationSCOPE OF WORK - SUBSTATION
SCOPE OF WORK - SUBSTATION VI - i TABLE OF CONTENTS 4.2 SCOPE OF WORK - SUBSTATIONS... 1 4.2.1 General... 1 4.2.2 Standard Substation... 2 4.2.3 33 kv Switchgear GIS Type... 2 4.2.3.1 Transformer Bay...
More informationElectric Power Distribution
Electric Power Distribution A S Pabla Consulting Engineer and Former Chief Engineer Punjab State Electricity Board McGraw-Hill New York Chicago San Francisco Lisbon London Madrid Mexico City Milan New
More informationHow To Write A Report On The Afghanistan Distribution System
AYBAK CITY (SAMANGAN PROVINCE) DISTRIBUTION SYSTEM CLOSE-OUT REPORT Prepared by: Raul Zuniga/Clayton Strampher/Jack Whippen/Tufail Memon Date of Report: May 3, 2006 Project/Action Area: Distribution Project
More informationPower products and systems. Intelligent solutions for power distribution Zone concept
Power products and systems Intelligent solutions for power distribution Zone concept Securing continuous power supply ABB is one of the world's leading power and automation technology companies whose products,
More informationSF 6 Gas Insulated Switchgear Type SDF for 170 kv
Three Phase Encapsulated Type SF 6 Gas Insulated Switchgear Type SDF for 170 kv 06B1-E-0001 With Trustworthy Technology, Structure Fuji Electric as a manufacturer of comprehensive substation equipment
More informationFIXED CHARGE: This is a cost that goes towards making the service available, including
ELECTRICITY BILL COMPONENTS FIXED CHARGE: This is a cost that goes towards making the service available, including installation and maintenance of poles, power lines and equipment, and 24-hour customer
More informationENERGY CRISIS IN NIGERIA: TECHNICAL ISSUES AND SOLUTIONS. Engr. D.J. Obadote
ENERGY CRISIS IN NIGERIA: TECHNICAL ISSUES AND SOLUTIONS By Engr. D.J. Obadote B.Eng (Hons); M.Eng.; FCIM; MNSE; MNIEM; R.Eng. Principal Manager (Performance Management) Jebba Hydro Power Business Unit
More informationV1.8 0 - N ovember 2015. Distribution Network Asset Data Available To Third Parties
V1.8 0 - N ovember 2015 Distribution Network Asset Data Available To Third Parties How To Request Data LinesearchBeforeUDig (http://www.linesearchbeforeudig.co.uk) This service is available 24/7 365 days
More informationAbout our Chairman cum- Managing Director
INTEGRATED GROUP Complete Range of Power Transmission and Distribution Equipments & Head office- SO 2-5, Second Floor, Amarjyoti Palace, Lokmat Square, Wardha Road, Nagpur-440012 Group E-mail ID : enquiry@integratedgroup.asia
More informationSTRATEGIC ISSUES OF THE ELECTRICITY COMPANY OF GHANA PRESENTATION BY MR. WILLIAM HUTTON-MENSAH (AG. MANAGING DIRECTOR) ELECTRICITY COMPANY OF GHANA
STRATEGIC ISSUES OF THE ELECTRICITY COMPANY OF GHANA PRESENTATION BY MR. WILLIAM HUTTON-MENSAH (AG. MANAGING DIRECTOR) OUTLINE OF PRESENTATION (ECG) 2 Introduction Map of Operational Area Company Mandate,
More informationLow Voltage Asset Management (LVAM) The key to reliable and safe electricity
Low Voltage Asset Management (LVAM) The key to reliable and safe electricity Archie Jaykaran Distribution Division Eskom SA Contents Change drivers Scope, Approach, Project status LV Planning and Design
More informationPower Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.
Power Voltage Transformers for Air Insulated Substations THE PROVEN POWER. Introduction Trench Power Voltage Transformers (Power VTs) combine the attributes of an inductive voltage transformer with the
More informationOUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd
OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd ACTOM OUTDOOR DISCONNECTORS Single Side Break (SSB) Disconnector 22-132 kv, 800-1 A, 25 ka - 3s Typical bearing assembly. Voltage range 11 kv to 132
More information3. TYPES OF SERVICE AVAILABLE. 3.1 Scope
3. TYPES OF SERVICE AVAILABLE 3.1 Scope UI supplies 60 hertz, alternating current with different voltage and ampere ratings. Not all voltage and ampere ratings are available throughout the entire service
More informationMEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS
MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS Meher Capacitors offers reliable and innovative products and solutions in the fields of Reactive Power Compensation, Power Quality and Energy
More informationAbout us. Eugensa is an ISO 9001:2008 certified company. CERT
About us CERT Eugensa JSC was established in Lithuania in 1996 and since then has become one of the regions largest electrical contractors specialising in the design, installation and maintenance of electrical,
More informationDistribution Design Manual
1 6 DESIGN PARAMETERS 4 6.1 Glossary and Definitions 4 6.2 Standard Voltages and Frequency 5 6.2.1 Transmission 5 6.2.2 Subtransmission 6 6.2.3 MV Distribution 6 6.2.4 LV Distribution 7 6.3 Point of Supply
More informationBuilding Electrical Infrastructure
Building Electrical Infrastructure Industrial & Commercial Connections, Industrial / Urban Residential Development, Asset Relocation, Street Lighting Our Company Our vision is to combine electrical engineering
More informationProduct brochure Multi Functional Switchgear PASS M00 72.5 kv Flexible and compact switchgear solutions for windfarms
Product brochure Multi Functional Switchgear PASS M00 72.5 kv Flexible and compact switchgear solutions for windfarms The future of Wind Farms As offshore wind farms move towards deploying higher capacity
More informationThink global, act local.
Think global, act local. 2 HISTORY History Saima Nigeria Limited was founded in 1980 jointly with Nigerian entrepreneurs as an international freight-forwarding, ship-owning company, shipping agent, and
More informationELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F
ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F TABLE OF CONTENTS Appendix F - Electrical Engineering Design Criteria F.1 Introduction...F-1 F.2 Codes and Standards...F-1 F.3 Switchyard and Transformers...F-1
More informationSWITCH YARD OPERATION IN THERMAL POWER PLANT(KaTPP Jhalawar Rajasthan)
From the SelectedWorks of Radhey Shyam Meena Winter July 12, 2012 SWITCH YARD OPERATION IN THERMAL POWER PLANT(KaTPP Jhalawar Rajasthan) RADHEY SHYAM MEENA, Er. Available at: http://works.bepress.com/radhey_meena/5/
More informationMEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
More informationApproved Meter Sockets and Cabinets
Single Unit Residential Guide 1 PHASE, 120/240 VOLT S METERING (Metering sockets and cabinets are supplied by Customer). Outdoor meter mounting height is 1730 mm ( 5 8 ) to center of meter ± 100 mm ( 4
More informationOFFSHORE WIND FARM ELECTRICAL CONNECTION OPTIONS. W.Grainger 1 and N.Jenkins 2 SYNOPSIS
OFFSHORE WIND FARM ELECTRICAL CONNECTION OPTIONS W.Grainger 1 and N.Jenkins 2 1 Border Wind Ltd, Hexham 2 Dept of Electrical Engineering and Electronics, UMIST SYNOPSIS The development of large scale offshore
More informationSUMMARY OF PRICES FOR POWER LINE CARRIER COUPLING EQUIPMENT FOR SUBSTATIONS / SWITCHING STATIONS
SUMMARY OF PRICES FOR POWER LINE CARRIER COUPLING EQUIPMENT FOR SUBSTATIONS / SWITCHING STATIONS PRICES (units) (Base). POWER LINE CARRIER COUPLING EQUIPMENT FOR SUBSTATIONS / SWITCHING STATIONS- for establishment
More informationUTTAR PRADESH ELECTRICITY REGULATORY COMMISSION
UTTAR PRADESH ELECTRICITY REGULATORY COMMISSION COST DATA BOOK FOR RECOVERY OF EXPENSES & OTHER CHARGES FROM PROSPECTIVE CONSUMERS FOR TAKING ELECTRIC SUPPLY (APPLICABLE TO ALL DISTRIBUTION LICENSEES IN
More informationDistribution Substation Manual (DSM) Section I - Introduction
(DSM) Section I - Introduction March 2007 Document release information Client Project name Western Power Distribution Substation Manual Document number 3463019 Document title Revision status Introduction
More informationA least-cost electrification proposal for Kisiizi, Uganda Sten Bergman Sr. Energy Specialist, The World Bank
A least-cost electrification proposal for Kisiizi, Uganda Sten Bergman Sr. Energy Specialist, The World Bank 1. Introduction Kisiizi Hospital is a Church of Uganda "Private not-for-profit health care provider
More informationSOUTHERN MARYLAND ELECTRIC COOPERATIVE, INC. HUGHESVILLE, MD
SOUTHERN MARYLAND ELECTRIC COOPERATIVE, INC. HUGHESVILLE, MD HOLLAND CLIFF HEWITT ROAD 230 KV TRANSMISSION LINE PROJECT ELECTRIC ALTERNATIVE EVALUATION STUDY BLACK & VEATCH CORPORATION B&V Project 146026(G)
More informationNetworks. ESB Networks Ltd Basis of Charges for Connection to the Distribution System. Commercial and Customer Asset Management ESB Networks Ltd.
Networks ESB Networks Ltd Basis of Charges for Connection to the Distribution System Revision Date: 14/01/20010 Revision No.: 1 Document No: DOC-10129-AXQ Issued by: ESB Networks Ltd Approved by : CER
More informationModular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation
Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation Index News Introduction Applications & Segments Main Components Applicable Standards Technical characteristics
More informationES281 COMPANY-SPECIFIC APPENDICES TO ENA ENGINEERING RECOMMENDATION G81 PART 1
ES281 COMPANY-SPECIFIC APPENDICES TO ENA ENGINEERING RECOMMENDATION G81 PART 1 Design and Planning Specification for New Low Voltage Installations for Housing Developments 1. SCOPE This appendix to ENA
More informationEXPRESSION OF INTEREST
EXPRESSION OF INTEREST Contractor: WorleyParsons Canada Services Ltd. Project: Hebron Topsides Project Package: 2001 Switchgear and MV MCC s Category: XXXXX-XXXXX Closing Date: 31 October 2011 General
More informationPresentation to CIGRE Next Generation Network. Visit of Seine substation
Presentation to CIGRE Next Generation Network Visit of Seine substation Projet Seine 30 août 2012 Contents 0. Presentation of RTE 1. Power supply of «Ile-de-France» and Paris 2. 225 kv Paris substations
More informationAUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A
AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components
More informationUp-to-Date with Electrical Equipment
Figure 1. Parts of production lines 2 & 3. Viktor Stieger, ABB Switzerland Ltd, provides details on Qassim Cement Company s electrical upgrades. Up-to-Date with Electrical Equipment Introduction Qassim
More informationF.C. Chan General Manager, CLP Engineering Ltd., Hong Kong SAR, China
ELECTRIC POWER DISTRIBUTION SYSTEMS F.C. Chan General Manager, CLP Engineering Ltd., Hong Kong SAR, China Keywords: Distribution system planning, Load characteristics, Subtransmission Lines, Distribution
More informationCustomer Substation Manual 08/05/02
Customer Substation Manual Table of Contents Section Page 2 of 85 Description 0 Preface 010.00 General 010.10 Information Required for the Review of New Customer Substations 010.20 New Customer Substation
More informationBUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE
BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE Toll Free Telephone Numbers Residential Services 800.454.3853 Commercial Services 800.653.5307 Utility Locating Company N.C. 800.632.4949 S.C. 888.721.7877
More informationChapter 1. Network Structures
Chapter 1 Network Structures Definition Standard IEC 60038 defines voltage ratings as follows: Low voltage (): for a phase-to-phase voltage of between 100 V and 1,000 V, the standard ratings are: 400 V
More informationSchool District Design and Project Management For Rochester, NY
The following is a list of projects completed by Engineered Solutions or its President Eric Sheffer, P.E.: Medium Voltage Design and project management for replacement of 1500KVA double ended substation
More informationFor a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V - 690 V - 1000 V (at 50 Hz)
24 1. NETWORK CONFIGURATIONS definition Standard IEC 38 defines voltage ratings as follows: - Low voltage () For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V - 690
More informationThe current and future challenges of electricity market in Nigeria in the face of deregulation process
African Journal of Engineering Research Vol. 1(2), pp. 33-39, March 2013 Review The current and future challenges of electricity market in Nigeria in the face of deregulation process Titus Koledoye Olugbenga
More informationCode of Practice Electricity transmission and distribution asset management. February 2009
Code of Practice Electricity transmission and distribution asset management February 2009 CONTENTS 1 PREFACE...4 2 APPLICATION AND OBJECTIVES...5 3 SCOPE...6 4 DEFINITIONS...7 5 DESIGN AND CONSTRUCTION...11
More informationAppendix L Network Management Plan September 2011
Appendix L Network Management Plan September 2011 Access Arrangement Information for the period 1 July 2012 to 30 June 2017 (AAI) Access Arrangement Information for the period 1 July 2012 to 30 June 2017
More informationLadies and Gentlemen,
Ladies and Gentlemen, I would like to begin my speech by thanking deeply the Maniatakeion Foundation and especially the Chairman, Mr. Dimitris Maniatakis for his invitation and to congratulate him for
More informationTrip circuit supervision relay. Type RXTCS
Trip circuit supervision relay Type RXTCS ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while
More informationBC Hydro. Electric Distribution System Cost of Service Study
BC Hydro Electric Distribution System Reimer Consulting Group Inc. Arnie Reimer May 7, 2010 Table of Contents 1. Executive Summary... 3 2. BC Hydro Electric Distribution System... 4 2.1. General Description...
More informationOVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B
OVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B The OVR-3SP three-phase recloser style guide aids in the proper selection of your OVR-3SP style number. The OVR-3SP
More informationTECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT
TECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT 1.1 General 1.1.1 These Special Conditions of Contract supplement the General Instructions.
More informationAssessment of Nigeria power sub-sector and electricity generation projections
International Journal of Scientific & Engineering Research, Volume 2, Issue 11, November-2011 1 Assessment of Nigeria power sub-sector and electricity generation projections Engr. C. O. Osueke (Ph.D),
More informationOVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F
OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F The OVR three-phase recloser style guide aids in the proper selection of your OVR three-phase style number.
More informationCAPACITOR BANK TESTING SWP
1. PURPOSE AND SCOPE The purpose of this Standard Work Practice (SWP) is to standardise and prescribe the method for testing Capacitor Banks including capacitors, tuning reactors and inrush limiting reactors.
More informationCommonwealth of Puerto Rico PUERTO RICO ELECTRIC POWER AUTHORITY. ANNUAL BUDGET OF CAPITAL EXPENDITURES FISCAL YEAR 2003-2004 (Dollars in thousands)
No. Title Amount Production Plant Thermal Production Plant 100 New Generation 15,865 160 Improvements to Steam Boilers 13,289 165 Improvements to Steam Turbine Generator 11,093 170 Improvements to Steam
More informationNIGERIA ELECTRICITY INDUSTRY: ISSUES, CHALLENGES AND SOLUTIONS
Covenant University 38th Public Lecture NIGERIA ELECTRICITY INDUSTRY: ISSUES, CHALLENGES AND SOLUTIONS Claudius A. Awosope, Ph.D Professor of Electrical and Electronics Engineering. Deputy Dean, School
More informationElectrical Safety Tips. Help us keep you safe
Electrical Safety Tips Help us keep you safe To help you stay safe when using electricity, ActewAGL has compiled these electrical safety tips. For natural gas safety tips please see ActewAGL s natural
More informationINTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002
INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002 NEW GAS INSULATED SWITCHGEAR (GIS) FOR ALL MEDIUM VOLTAGE APPLICATIONS H. Fink, ABB Calor Emag Mittelspannungs GmbH; M. Hyrenbach, ABB Calor
More informationMax. Length of HTS Cables in the Future
Max. Length of HTS Cables in the Future K. Schippl, Nexans Deutschland Industries, Hannover, Germany TOPICS: Limitation of the cable design: 1. Physical limitations 2. Shipping limitations 3. Maintenance
More informationThe complete guide to Low Voltage switchgear
The complete guide to Low Voltage switchgear The complete guide to low voltage switchgear Contents 4-7 Merlin Gerin LV Switchgear An introduction to the Merlin Gerin low voltage range of switchgear, and
More informationESB Networks Response. ERGEG Consultation. Voltage Quality Regulation in Europe
NETWORKS ESB Networks Response to ERGEG Consultation on Voltage Quality Regulation in Europe Date: 22 February 2007 Distribution System Operator ESB Networks Page 1 of 12 Contents 1.0 INTRODUCTION...3
More informationFundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components
Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components Course No: E02-010 Credit: 2 PDH Boris Shvartsberg, Ph.D., P.E., P.M.P. Continuing Education
More informationAsset Management Plan
2014 Asset Management Plan www.topenergy.co.nz INTRODUCTION Introduction It gives me great pleasure to present Top Energy s 2014-2024 Network Asset Management Plan (AMP). The 2014 AMP follows on from the
More informationDESCRIPTION DWG DESCRIPTION DWG
DESCRIPTION DWG DESCRIPTION DWG Ferroresonance 3451/1 3451/2 3451/3 Electro-magnetic Fields (EMF) 3462/1 HV & LV Insulators (Links) 3463/1 A ORIGINAL ISSUE B 14.07.09 APPROVED DATE J. Brooks 25.02.03 INDEX
More informationTechnical Trial of Broadband IP/Internet over ESB Power Networks. Engineers Ireland. October 2006
Technical Trial of Broadband IP/Internet over ESB Power Networks Engineers Ireland October 2006 Outline of Presentation 1. Introduction to Broadband Power Line Carrier 2. Trial start up 1. Objectives 2.
More informationHigh Voltage (HV) Electricity System Safety Rules and Associated Safety Guidance
Annex I To Loughborough University (LU) Facilities Management (FM) Health and Safety Policy High Voltage (HV) Electricity System Safety Rules and Associated Safety Guidance 1. Introduction a. These Safety
More informationElectrical safety rules
Electrical safety rules 2015 DISCLAIMER The material contained in this publication has been developed for the use of ActewAGL, its contractors and all others working on or near ActewAGL s electricity
More informationCONNECTING YOU TO SPECIALIST ELECTRICAL SUPPORT services
CONNECTING YOU TO SPECIALIST ELECTRICAL SUPPORT services SpecialistS IN ELECTRICAL SUPPORT SERVICES TO MINING, UTILITIES & industry Ampcontrol is committed to supporting our customers to maintain efficient
More informationAurora Energy Asset Management Plan 2011
Aurora Energy Asset Management Plan 11 Prepared by Aurora Energy Ltd www.auroraenergy.com.au 1 Contents 1 Contents... 1 1. Introduction... Asset description... 18 3 Service levels... 4 4 Future demand...
More informationPaper on Basbar Trunking System for Electrical Supply to Industrial & commercial Installation
IOSR Journal of Engineering (IOSRJEN) ISSN (e): 2250-3021, ISSN (p): 2278-8719 Vol. 04, Issue 01 (January. 2014), V6 PP 01-12 www.iosrjen.org Paper on Basbar Trunking System for Electrical Supply to Industrial
More informationDisconnectors and Earthing Switches 36 kv up to 800 kv
Power Transmission and Distribution Disconnectors and Earthing Switches 36 kv up to 800 kv Ruhrtal & Siemens: A strong and successful team We manufacture high quality high-voltage disconnectors and earthing
More informationSolutions for Photovoltaic Systems. Large buildings and power plants
Solutions for Photovoltaic Systems Large buildings and power plants Helping you achieve the lowest cost of energy for your project When it comes to large-scale installations, you need a solar solution
More informationEDB Information Disclosure Requirements Information Templates for Schedules 11a 13
EDB Information Disclosure Requirements Information Templates for Schedules 11a 13 Disclosure Date 31 March 2015 Start Date (first day) 1 April 2015 Templates for Schedules 11a 13 (Asset Management Plan)
More information261000 Medium Voltage Electrical Distribution
Sections Included In This Standard: 1.1 General 1.2 Underground Cable 1.3 Medium Voltage Switches 1.4 Transformers 1.5 Electrical Manholes 1.6 Switch Vaults 1.7 Distribution Switchgear/Switchboards This
More informationESB Networks Ltd Statement of Charges
ESB Networks Ltd Statement of Charges Revision Date: 9/2014 Revision No.: 11 Document No: DOC-101209-AXR Issued by: ESB NETWORKS LTD Approved by : CER Effective Date: 01/10/2014 Commercial and Renewable
More informationELECTRICAL PLANNING AND DESIGN FOR GEOTHERMAL POWER PROJECTS.
ELECTRICAL PLANNING AND DESIGN FOR GEOTHERMAL POWER PROJECTS. Ivan Hunt PB Power, GENZL Division. PO Box 668, Wellington, New Zealand. Key Words: design, electrical, geothermal, planning ABSTRACT This
More information