Display Group Parameters
|
|
- Eustacia Allison
- 7 years ago
- Views:
Transcription
1 1 Display Group Parameters No. Parameter Min/Max Display/Options d1 [Output Freq]./[Maximum Freq].1 Hz d2 [Commanded Freq]./[Maximum Freq].1 Hz d3 [Output Current]./Drive Amps 2.1 Amps d4 [Output Voltage] /Drive Rated Volts 1 VAC d5 [DC Bus Voltage] Based on Drive Rating 1 VDC d6 [Drive Status] /1 (1 = Condition True) Bit 3 Bit 2 Bit 1 Bit Decelerating Accelerating Forward Running d7- [Fault x Code] F2/F122 F1 d9 d1 [Process Display]./ d12 [Control Source] /9 Bit 1 = Speed Command Bit = Start Command (See P38; 9 = Jog Freq ) (See P36; 9 = Jog ) d13 [Contrl In Status] /1 (1 = Input Present) Bit 3 Bit 2 Bit 1 Bit Dynamic Brake Stop Input Dir/Run REV Start/Run FWD d14 [Dig In Status] /1 (1 = Input Present) Bit 3 Bit 2 Bit 1 Bit Digital In4 Sel Digital In3 Sel Digital In2 Sel Digital In1 Sel d15 [Comm Status] /1 (1 = Condition True) Bit 3 Bit 2 Bit 1 Bit Fault Occurred RS485 Option Transmitting Receiving d16 [Control SW Ver] 1./ d17 [Drive Type] 11/ d18 [Elapsed Run Time] /9999 Hrs 1 = 1 Hrs d19 [Testpoint Data] /FFFF 1 Hex d2 [Analog In -1V]./1.%.1% d21 [Analog In 4-2mA]./1.%.1% d22 [Output Power]./Drive Power 2.1 kw d23 [Output Powr Fctr]./18. deg.1 deg d24 [Drive Temp] /12 degc 1 degc d25 [Counter Status] / d26 [Timer Status]./ Secs d28 [Stp Logic Status] /7 1 Smart Start-Up with Basic Program Group Parameters The PowerFlex 4 is designed so that start up is simple and efficient. The Program Group contains the most commonly used parameters. = Stop drive before changing this parameter. P31 [Motor NP Volts] 2/Drive Rated Volts 1 VAC Based on Drive Rating Set to the motor nameplate rated volts. P32 [Motor NP Hertz] 15/4 Hz 1 Hz 6 Hz Set to the motor nameplate rated frequency. P33 [Motor OL Current]./(Drive Rated Amps 2).1 Amps Based on Drive Rating Set to the maximum allowable motor current. P34 [Minimum Freq]./4. Hz.1 Hz. Hz Sets the lowest frequency the drive will output continuously. P35 [Maximum Freq] /4 Hz 1 Hz 6 Hz Sets the highest frequency the drive will output. P36 [Start Source] /5 = Keypad (1) Sets the control scheme used to start the drive. (1) When active, the Reverse key is also active unless disabled by A95 [Reverse Disable]. 1 = 3-Wire 2 = 2-Wire 3 = 2-W Lvl Sens 4 = 2-W Hi Speed 5 = Comm Port P37 [Stop Mode] /7 = Ramp, CF (1) Active stop mode for all stop sources [e.g. keypad, 1 = Coast, CF (1) run forward (I/O Terminal 2), run reverse (I/O 2 = DC Brake, CF (1) Terminal 3), RS485 port] except as noted below. 3 = DCBrkAuto,CF (1) Important: I/O Terminal 1 is always a coast to 4 = Ramp stop input except when P36 [Start Source] is set 5 = Coast for 3-Wire control. When in three wire control, I/O 6 = DC Brake Terminal 1 is controlled by P37 [Stop Mode]. 7 = DC BrakeAuto (1) Stop input also clears active fault.
2 2 = Stop drive before changing this parameter. P38 [Speed Reference] /6 = Drive Pot Sets the source of the speed reference to the 1 = InternalFreq drive. 2 = -1V Input Important: When A51 or A52 [Digital Inx Sel] is 3 = 4-2mA Input set to option 2, 4, 5, 6, 13 or 14 and the digital 4 = Preset Freq input is active, A51, A52, A53 or A54 will 5 = Comm Port override the speed reference commanded by this 6 = Stp Logic parameter. Refer to Chapter 1 of the PowerFlex 4 User Manual on CD for details. P39 [Accel Time 1]./6. Secs.1 Secs 1. Secs Sets the rate of accel for all speed increases. P4 [Decel Time 1].1/6. Secs.1 Secs 1. Secs Sets the rate of decel for all speed decreases. P41 [Reset To Defalts] /1 = Ready/Idle Resets all parameter values to factory defaults. 1 = Factory Rset Advanced Group Parameters A51 A52 A53 A54 [Digital In1 Sel] I/O Terminal 5 [Digital In2 Sel] I/O Terminal 6 [Digital In3 Sel] I/O Terminal 7 [Digital In4 Sel] I/O Terminal 8 /25 = Not Used 1 = Acc & Dec 2 2 = Jog 3 = Aux Fault 4 = Preset Freq 5 = Local 6 = Comm Port 7 = Clear Fault 8 = RampStop,CF 9 = CoastStop,CF 1 = DCInjStop,CF 11 = Jog Forward 12 = Jog Reverse 13 = 1V In Ctrl 14 = 2mA In Ctrl 15 = PID Disable 16 = MOP Up 17 = MOP Down 18 = Timer Start 19 = Counter In 2 = Reset Timer 21 = Reset Countr 22 = Rset Tim&Cnt 23 = Logic In1 24 = Logic In2 25 = Current Lmt A55 [Relay Out Sel] /2 = Ready/Fault 1 = At Frequency 2 = MotorRunning 3 = Reverse 4 = Motor Overld 5 = Ramp Reg 6 = Above Freq 7 = Above Cur 8 = Above DCVolt 9 = Retries Exst 1 = Above Anlg V 11 = Logic In 1 12 = Logic In 2 13 = Logic 1 & 2 14 = Logic 1 or 2 15 = StpLogic Out 16 = Timer Out 17 = Counter Out 18 = Above PF Ang 19 = Anlg In Loss 2 = ParamControl A56 [Relay Out Level]./ A58 A61 [Opto Out1 Sel] [Opto Out2 Sel] /2 = Ready/Fault 1 = At Frequency 2 = MotorRunning 3 = Reverse 4 = Motor Overld 5 = Ramp Reg 6 = Above Freq 7 = Above Cur 8 = Above DCVolt 9 = Retries Exst 1 = Above Anlg V 11 = Logic In 1 12 = Logic In 2 13 = Logic 1 & 2 14 = Logic 1 or 2 15 = StpLogic Out 16 = Timer Out 17 = Counter Out 18 = Above PF Ang 19 = Anlg In Loss 2 = ParamControl 2 1 A59 A62 [Opto Out1 Level] [Opto Out2 Level]./ A55, A58 & A61 Setting A56, A59 & A62 Min/Max 6 /4 Hz 7 /18% 8 /815 Volts 1 /1% 16.1/9999 Secs 17 1/9999 Counts 18 1/18 degs 2 /1
3 3 A64 [Opto Out Logic] /3 1 A64 Option Opto Out1 Logic Opto Out2 Logic NO (Normally Open) NO (Normally Open) 1 NC (Normally Closed) NO (Normally Open) 2 NO (Normally Open) NC (Normally Closed) 3 NC (Normally Closed) NC (Normally Closed) A65 [Analog Out Sel] /14 1 A66 [Analog Out High] /8% 1% 1% A67 [Accel Time 2]./6. Secs.1 Secs 2. Secs A68 [Decel Time 2].1/6. Secs.1 Secs 2. Secs A69 [Internal Freq]./4. Hz.1 Hz 6. Hz A7 A71 A72 A73 A74 A75 A76 A77 Option Output Range Minimum Output Value Maximum Output Value [Analog Out High] DIP Switch Position OutFreq -1-1V V = Hz P35 [Maximum Freq] -1V 1 OutCurr -1-1V V = Amps 2% Drive Rated FLA -1V 2 OutVolt -1-1V V = Volts 12% Drive Rated Output Volts -1V 3 OutPowr -1-1V V = kw 2% Drive Rated Power -1V 4 TstData -1-1V V = (Hex FFFF) -1V 5 OutFreq -2-2mA ma = Hz P35 [Maximum Freq] -2mA 6 OutCurr -2-2mA ma = Amps 2% Drive Rated FLA -2mA 7 OutVolt -2-2mA ma = Volts 12% Drive Rated Output Volts -2mA 8 OutPowr -2-2mA ma = kw 2% Drive Rated Power -2mA 9 TstData -2-2mA ma = (Hex FFFF) -2mA 1 OutFreq mA 4 ma = Hz P35 [Maximum Freq] -2mA 11 OutCurr mA 4 ma = Amps 2% Drive Rated FLA -2mA 12 OutVolt mA 4 ma = Volts 12% Drive Rated Output Volts -2mA 13 OutPowr mA 4 ma = kw 2% Drive Rated Power -2mA 14 TstData mA 4 ma = (Hex FFFF) -2mA [Preset Freq ] (1) [Preset Freq 1] [Preset Freq 2] [Preset Freq 3] [Preset Freq 4] [Preset Freq 5] [Preset Freq 6] [Preset Freq 7]./4. Hz.1 Hz. Hz 5. Hz 1. Hz 2. Hz 3. Hz 4. Hz 5. Hz 6. Hz (1) To activate [Preset Freq ] set P38 [Speed Reference] to option 4. of Digital In 1 (I/O Terminal 5) of Digital In 2 (I/O Terminal 6) of Digital In 3 (I/O Terminal 7) A78 [Jog Frequency]./[Maximum Freq].1 Hz 1. Hz A79 [Jog Accel/Decel].1/6. Secs.1 Secs 1. Secs A8 [DC Brake Time]./99.9 Secs.1 Secs. Secs A setting of 99.9 Secs = Continuous A81 [DC Brake Level]./(Drive Amps 1.8).1 Amps Amps.5 A82 [DB Resistor Sel] /99 = Disabled 1 = Normal RA Res Frequency Source Accel / Decel Parameter Used (2) [Preset Freq ] [Accel Time 1] / [Decel Time 1] 1 [Preset Freq 1] [Accel Time 1] / [Decel Time 1] 1 [Preset Freq 2] [Accel Time 2] / [Decel Time 2] 1 1 [Preset Freq 3] [Accel Time 2] / [Decel Time 2] 1 [Preset Freq 4] [Accel Time 1] / [Decel Time 1] 1 1 [Preset Freq 5] [Accel Time 1] / [Decel Time 1] 1 1 [Preset Freq 6] [Accel Time 2] / [Decel Time 2] [Preset Freq 7] [Accel Time 2] / [Decel Time 2] (2) When a Digital Input is set to Accel 2 & Decel 2, and the input is active, that input overrides the settings in this table. 2 = NoProtection 3-99 = % of Duty Cycle A83 [S Curve %] /1% 1% % (Disabled) A84 [Boost Select] /14 Settings in % of base voltage. 8 Only active when A125 [Torque Perf Mode] is = Custom V/Hz 7 (5, 7.5 & 1 set to V/Hz. Variable Torque Constant Torque HP Drives) 1 = 3., VT 5 =., no IR 1 = 1., CT 2 = 35., VT 6 =. 11 = 12.5, CT 3 = 4., VT 7 = 2.5, CT 12 = 15., CT 4 = 45., VT 8 = 5., CT 13 = 17.5, CT 9 = 7.5, CT 14 = 2., CT A85 [Start Boost]./25.%.1% 2.5% Only active when A84 [Boost Select] and A125 [Torque Perf Mode] are set to.
4 4 A86 [Break Voltage]./1.%.1% 25.% Only active when A84 [Boost Select] and A125 [Torque Perf Mode] are set to. A87 [Break Frequency]./4. Hz.1 Hz 15. Hz Only active when A84 [Boost Select] and A125 [Torque Perf Mode] are set to. A88 [Maximum Voltage] 2/Rated Volts 1 VAC Rated Volts A89 [Current Limit 1].1/(Drive Amps 1.8).1 Amps Amps 1.5 A9 [Motor OL Select] /2 = No Derate 1 = Min Derate 2 = Max Derate A91 [PWM Frequency] 2./16. khz.1 khz 4. khz A92 [Auto Rstrt Tries] /9 1 A93 [Auto Rstrt Delay]./3. Secs.1 Secs 1. Secs A94 [Start At PowerUp] /1 = Disabled 1 = Enabled A95 [Reverse Disable] /1 = Rev Enabled 1 = Rev Disabled A96 [Flying Start En] /1 = Disabled 1 = Enabled A97 [Compensation] /3 = Disabled 2 = Mechanical 1 1 = Electrical 3 = Both A98 [SW Current Trip]./(Drive Amps 2).1 Amps. (Disabled) A99 [Process Factor].1/ A1 [Fault Clear] /2 = Ready/Idle 1 = Reset Fault 2 = Clear Buffer A11 [Program Lock] /9999 = Unlocked 1 = Locked A12 [Testpoint Sel] 4/FFFF 1 Hex 4 A13 [Comm Data Rate] /5 = 12 3 = 96 3 Power to drive must be cycled before any 1 = 24 4 = 19.2K 2 = 48 5 = 38.4K A14 [Comm Node Addr] 1/ Power to drive must be cycled before any A15 [Comm Loss Action] /3 = Fault 2 = Stop 1 = Coast Stop 3 = Continu Last A16 [Comm Loss Time].1/6. Secs.1 5. A17 [Comm Format] /2 = RTU 8-N-1 1 = RTU 8-E-1 Power to drive must be cycled before any A18 [Language] 1/1 1 = English 2 = Français 3 = Español 4 = Italiano 5 = Deutsch 2 = RTU 8-O-1 6 = Reserved 7 = Português 8 = Reserved 9 = Reserved 1 = Nederlands A11 [Anlg In -1V Lo]./1.%.1%.% A111 [Anlg In -1V Hi]./1.%.1% 1.% A112 [Anlg In4-2mA Lo]./1.%.1%.% A113 [Anlg In4-2mA Hi]./1.%.1% 1.% A114 [Slip FLA]./1. Hz.1 Hz 2. Hz A118 [Current Limit 2].1/(Drive Amps 1.8).1 Amps Amps 1.5 A119 [Skip Frequency] /4 Hz 1 Hz Hz A12 [Skip Freq Band]./3. Hz.1 Hz. Hz A121 [Stall Fault Time] /5 = 6 Seconds 1 = 12 Seconds 2 = 24 Seconds A122 [Analog In Loss] /6 = Disabled 1 = Fault (F29) 2 = Stop 3 = Zero Ref 3 = 36 Seconds 4 = 48 Seconds 5 = Flt Disabled 4 = Min Freq Ref 5 = Max Freq Ref 6 = Int Freq Ref A123 [1V Bipolar Enbl] /1 = Uni-Polar In 1 = Bi-Polar In A124 [Var PWM Disable] /1 = Enabled 1 = Disabled A125 [Torque Perf Mode] /1 = V/Hz 1 = Sensrls Vect 1 A126 [Motor NP FLA] Drive Amps.1/2.1 Amps Rated Amps 1
5 A127 [Autotune] /2 = Ready/Idle 2 = Rotate Tune 1 = Static Tune A128 [IR Voltage Drop]./23. VAC.1 VAC Rated Volts A129 [Flux Current Ref]./[Motor NP Volts].1 Amps Rated Amps A13 [PID Trim Hi]./ A131 [PID Trim Lo]./ A132 [PID Ref Sel] /8 = PID Disabled 5 = Setpnt, Trim 1 = PID Setpoint 2 = -1V Input 3 = 4-2mA Input 4 = Comm Port 6 = -1V, Trim 7 = 4-2mA, Trim 8 = Comm, Trim A133 [PID Feedback Sel] /2 = -1V Input 2 = Comm Port 1 = 4-2mA Input A134 [PID Prop Gain]./ A135 [PID Integ Time]./999.9 Secs.1.1 A136 [PID Diff Rate]./99.99 (1/Secs).1.1 A137 [PID Setpoint]./1.%.1%.% A138 [PID Deadband]./1.%.1%.% A139 [PID Preload]./4. Hz.1 Hz. Hz A14- A147 A15- A157 [Stp Logic -7] 1/BAFF 4 Digits For a list of digit options, refer to the PowerFlex 4 User Manual on the CD supplied with the drive. F1 [Stp Logic Time -7]./999.9 Secs.1 Secs 3. Secs Fault Codes To clear a fault, press the Stop key, cycle power or set A1 [Fault Clear] to 1 or 2. No. Fault Description F2 Auxiliary Input (1) Check remote wiring. F3 Power Loss Monitor the incoming AC line for low voltage or line power interruption. F4 UnderVoltage (1) Monitor the incoming AC line for low voltage or line power interruption. F5 OverVoltage (1) Monitor the AC line for high line voltage or transient conditions. Bus overvoltage can also be caused by motor regeneration. Extend the decel time or install dynamic brake option. F6 Motor Stalled (1) Increase [Accel Time x] or reduce load so drive output current does not exceed the current set by parameter A89 [Current Limit]. F7 Motor Overload (1) An excessive motor load exists. Reduce load so drive output current does not exceed the current set by parameter P33 [Motor OL Current]. F8 Heatsink OvrTmp (1) Check for blocked or dirty heat sink fins. Verify that ambient temperature has not exceeded 4 C (14 F) for IP 3/NEMA 1/UL Type 1 installations or 5 C (122 F) for Open type installations. Check fan. F12 HW OverCurrent (1) Check programming. Check for excess load, improper DC boost setting, DC brake volts set too high or other causes of excess current. F13 Ground Fault Check the motor and external wiring to the drive output terminals for a grounded condition. F29 Analog In Loss An analog input is configured to fault on signal loss. A signal loss has occurred. F33 Auto Rstrt Tries Correct the cause of the fault and manually clear. F38 Phase U to Gnd Check the wiring between the drive and motor. Check motor for grounded phase. F39 Phase V to Gnd Replace drive if fault cannot be cleared. F4 Phase W to Gnd F41 Phase UV Short Check the motor and drive output terminal wiring for a shorted condition. F42 Phase UW Short Replace drive if fault cannot be cleared. F43 Phase VW Short F48 Params Defaulted The drive was commanded to write default values to EEPROM. Clear the fault or cycle power to the drive. Program the drive parameters as needed. F63 SW OverCurrent (1) Check load requirements and A98 [SW Current Trip] setting. F64 Drive Overload Reduce load or extend Accel Time. F7 Power Unit Cycle power. Replace drive if fault cannot be cleared. F8 Autotune Failure The autotune function was either cancelled by the user of failed. F81 Comm Loss If adapter was not intentionally disconnected, check wiring to the port. Replace wiring, port expander, adapters or complete drive as required. Check connection. An adapter was intentionally disconnected. Turn off using A15 [Comm Loss Action]. F1 Parameter Checksum Restore factory defaults. F122 I/O Board Fail Cycle power. Replace drive if fault cannot be cleared. (1) Auto-Reset/Run type fault. Configure with parameters A92 and A93. 5
PowerFlex 40 Adjustable Frequency AC Drive
PowerFlex 4 Adjustable Frequency AC Drive Quick Start This Quick Start guide summarizes the basic steps needed to install, start-up and program the PowerFlex 4 Adjustable Frequency AC Drive. The information
More informationSJ200 Series Inverter Quick Reference Guide
SJ2 Series Inverter Quick Reference Guide Single-phase Input 2V Class Three-phase Input 2V Class Three-phase Input 4V Class Hitachi Industrial Equipment Systems Co., Ltd. Manual No. NB6501XA March 24 Caution:
More informationNX Series Inverters. HVAC Pocket Programming Guide
NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product
More informationGPD 506/P5 Start-up Procedure and Checklist
GPD 506/P5 Start-up Procedure and Checklist Preparation for GPD506/P5 Drive Start-Up...2 HVAC Start-Up Procedure for GPD 506/P5 WITH Bypass Option:...4 HVAC Start-Up Procedure for GPD 506/P5 WITHOUT Bypass
More informationConfiguring Allen-Brandly ControlLogix PLC with Moxa MGate 5105-MB-EIP. 1 Application Description... 3. 1.1 Objective... 3 1.2 Goals...
Moxa MGate 5105-MB-EIP Contents Moxa Technical Support Team support@moxa.com 1 Application Description... 3 1.1 Objective... 3 1.2 Goals... 3 2 System Topology... 3 3 Hardware and Software Requirements...
More informationMC Series Drives. Flexible, simple, rugged, robust! Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.actechdrives.com - Email: info@actechdrives.
Drives Flexible, simple, rugged, robust! Our promise Commitment to Price Leadership Price leadership is serious business. It takes continuous life cycle management to make price leadership a sustainable
More information1 Application Description... 3. 1.1 Objective... 3 1.2 Goals... 3
Contents Moxa Technical Support Team support@moxa.com 1 Application Description... 3 1.1 Objective... 3 1.2 Goals... 3 2 System Topology... 3 3 Hardware and Software Requirements... 4 4 Configuration...
More informationPowerFlex 70 and 700 Packages for Fan and Pump Applications
Installation Instructions PowerFlex 70 and 700 Packages for Fan and Pump Applications Catalog Numbers V, W Important User Information Read this document and the documents listed in the additional resources
More informationApéndice E Listado de constantes
Listado de constantes Operation U1 Monitor U1--01 Frequency Ref Hz -- -- Q Q Q Q U1--02 Output freq Hz -- -- Q Q Q Q U1--03 Output current A -- -- Q Q Q Q U1--04 Control Method -- -- -- Q Q Q Q U1--05
More informationFlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3
FlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3 Instruction Manual D2-3405-2 The information in this manual is subject to change without notice. Throughout this manual, the following
More informationA1000 Cheat Sheet (Open Loop Vector)
A1000 Cheat Sheet (Open Loop Vector) The following procedure is a supplement to supplied with this equipment and will guide the user in properly wiring the A1000 and. It will also show the user how to
More informationACS800. Firmware Manual ACS800 Standard Control Program 7.x
ACS800 Firmware Manual ACS800 Standard Control Program 7.x ACS800 Standard Control Program 7.x Firmware Manual 3AFE64527592 REV I EN EFFECTIVE: 18.05.2007 2007 ABB Oy. All Rights Reserved. 5 Table of
More information32VFD Variable Frequency Drives for Centrifugal Chillers
32VFD 32VFD Variable Frequency Drives for Centrifugal Chillers ENERGY-SAVING CONTROL FOR CENTRIFUGAL CHILLERS Reduce energy consumption in your existing centrifugal chiller Your chiller was specified to
More informationVLT 6000 HVAC. Contents
Contents Introduction Safety...3 Safety Guidelines...3 Warnings Against Unintended Start...3 Introduction...4 About this manual...4 Assumptions...4 References...4 Trademarks...5 Programming the VLT 6000
More informationParameter Settings for PowerFlex Drives Using Sine Wave Filters, dv/dt Filters, and Adjustable Voltage
Application Technique Parameter Settings for PowerFlex Drives Using Sine Wave Filters, dv/dt Filters, and Adjustable Voltage PowerFlex 750-Series, 700, and 700VC AC Drives Topic Page About This Document
More informationEasy to connect - Easy to configure Easy to install
SIMPLE TO USE... CG Drive- SK is an easy drive - easy to connect, easy to configure and easy to install. Easy to connect - All connectors are generously sized and clearly labeled. Easy to configure - The
More informationTechnical Data. 1336 PLUS II Adjustable Frequency AC Drive
Technical Data 1336 PLUS II Adjustable Frequency AC Drive A Complete Line of Drives for a Complete Family of Products Available in ratings from 0.37 to 448 kw (0.5 to 600 horsepower), the drive helps to
More informationVariable Speed AC Motor Drives SM-Basic Installation and Operation Manual
ELECTRIC MOTORS, GEARMOTORS AND DRIVES Variable Speed AC Motor Drives SM-Basic Installation and Operation Manual We, EC Declaration of Conformity In accordance with EN45014:1998 Leeson Electric Corporation
More informationAPPENDIX. SureSERVO QUICK START GUIDE. In This Appendix... Quick Start for SureServo Drives...A 2. Tuning Quick Start for SureServo Drives...
SureSERVO QUICK START GUIDE APPENDIX BA In This Appendix... Quick Start for SureServo Drives.............A 2 Spin the Motor......................................A 2 Position Mode Quick Start (Pt & Pr)......................A
More informationACS800. Firmware Manual ACS800 Standard Control Program 7.x
ACS800 Firmware Manual ACS800 Standard Control Program 7.x ACS800 Standard Control Program 7.x Firmware Manual 3AFE64527592 REV L EN EFFECTIVE: 2011-08-25 2011 ABB Oy. All Rights Reserved. 5 Table of
More informationInstallation and Start-up Guide. RS485 and RS232 Adapter for product type ACS 140
Installation and Start-up Guide RS485 and RS232 Adapter for product type ACS 140 ACS 140 RS485 and RS232 Adapter Installation and Start-up Guide 3AFY 61492828 R0125 REV A EN Effective: 1.10.1998 1998
More informationHF430 AC Drive Pocket Guide
HF430 AC Drive Pocket Guide Safety Refer to the Safety section in the HF430 drive instruction manual for full details. As a minimum, observe the following. DANGER DANGER HAZARD OF ELECTRICAL SHOCK OR BURN.
More informationsmd Series Drives Modbus Communications Reference Guide
smd Series Drives Modbus Communications Reference Guide About These Instructions This documentation applies to the use of an smd Series Variable Frequency Drive in a Modbus Network and should be used in
More informationMEMOBUS/Modbus Communications
2 2.1 MEMOBUS/MODBUS CONFIGURATION............260 2.2 COMMUNICATION SPECIFICATIONS..............261 2.3 COMMUNICATION TERMINAL RESISTANCE........262 2.4 CONNECTING A PLC...........................263 2.5
More informationVARIABLE FREQUENCY DRIVES Revised 4/30/2015 23 81 07-1 Mechanical Systems
SECTION 23 81 07 - VARIABLE FREQUENCY DRIVES PART 1 - GENERAL 1.1 SUMMARY A. This section includes all variable frequency drives. All standard and optional features shall be included within the VFD panel
More informationTABLE OF CONTENTS. Fig. 1 EV Pictorial Wiring Diagram 5. Section 2 Inverter Option Modules 6
TABLE OF CONTENTS Introduction.. 3 Section 1 Safety Precautions.. 3 1.1 Preface.. 3 1.2 Receiving and Inspection... 3 1.3 Installation and Pre-operation 4 1.4 During Power ON. 4 Fig. 1 EV Pictorial Wiring
More informationSoftstarters. Type PST/PSTB Fieldbus communication CANopen for PST sw CU 06.00.00. 1SFC132070M0201 February 2011 1SFC132070M0201 1
Softstarters Type PST/PSTB Fieldbus communication CANopen for PST sw CU 06.00.00 1SFC132070M0201 February 2011 1SFC132070M0201 1 CANopen The CANopen protocol is a fieldbus protocol that provides full control
More informationAC ADJUSTABLE SPEED DRIVES MICRO SERIES INVERTERS
MICRO SERIES INVERTERS MICRO SERIES INVERTER DRIVES Full feature, ultra-friendly operation. Programs and reads-out in plain English. Intelligent Power Module-IGBT s with a 16 bit Intel microprocessor.
More informationCONSTRUCTION STANDARDS DIVISION 23 HEATING VENTILATING AND AIR CONDITIONING
PART 1-GENERAL 1.01 DESCRIPTION A. This specification is to cover a complete Variable Frequency motor Drive (VFD) consisting of a pulse width modulated (PWM) inverter designed for use on a standard NEMA
More informationAnalog Servo Drive 25A8
Description Power Range NOTE: This product has been replaced by the AxCent family of servo drives. Please visit our website at www.a-m-c.com or contact us for replacement model information and retrofit
More informationSAFETY INSTRUCTIONS WARNING
Important User Information Thank you for purchasing LS Variable Frequency Drives! SAFETY INSTRUCTIONS Always follow safety instructions to prevent accidents and potential hazards from occurring. In this
More informationMOVFR ELECTRICAL ADJUSTMENTS. G.A.L. MFG. CORP. NEW YORK CITY U.S.A. http://www.gal.com
MOVFR ELECTRICAL ADJUSTMENTS G.A.L. MFG. CORP. NEW YORK CITY U.S.A. http://www.gal.com 1 ELECTRICAL ADJUSTMENTS ADJUSTING INSTRUCTIONS FOR THE G.A.L. VARIABLE FREQUENCY CLOSED LOOP DOOR OPERATOR TYPE MOVFR
More information1000 Hz High Frequency Custom Software
YASKAWA AC Drive - V1000 Option 1000 Hz High Custom Software Supplement Software No. VSV91005X To properly use the product, read this manual thoroughly and retain for easy reference, inspection, and maintenance.
More informationSAFETY INSTRUCTIONS WARNING
Thank you for purchasing LG Variable Frequency Drives! SAFETY INSTRUCTIONS Always follow safety instructions to prevent accidents and potential hazards from occurring. In this manual, safety messages are
More informationSAFETY INSTRUCTIONS. Always follow safety instructions to prevent accidents and potential hazards from occurring.
Thank you for purchasing LS Variable Frequency Drives! SAFETY INSTRUCTIONS Always follow safety instructions to prevent accidents and potential hazards from occurring. In this manual, safety messages are
More informationACS800. Firmware Manual ACS800 Pump Control Application Program 7.2 (+N687)
ACS800 Firmware Manual ACS800 Pump Control Application Program 7.2 (+N687) ACS800 Pump Control Application Program 7.2 Firmware Manual 3AFE68478952 REV D EN EFFECTIVE: 2012-03-01 2012 ABB Oy. All Rights
More informationUser Manual. MODBUS-RTU Option Board for SV-iS5 Series. LG Industrial Systems
User Manual MODBUS-RTU Option Board for SV-iS5 Series Read this manual carefully before using the MODBUS-RTU Option board and follow the instructions exactly. After reading this manual, keep it at handy
More informationPNSPO! Modbus Solution CP1H / CP1L / CJ1 / CJ2 / CS1. Version 2.05 6/18/2009
PNSPO!! Modbus Solution CP1H / CP1L / CJ1 / CJ2 / CS1 Version 2.05 6/18/2009 Section 1. Overview The Omron CP1H and CP1L PLCs offer a built in function called Easy Modbus, that performs a Modbus RTU Master
More informationABB general machinery drives. User s manual ACS355 drives
ABB general machinery drives User s manual ACS355 drives List of related manuals Drive manuals and guides Code (English) ACS355 user s manual 3AUA0000066143 1) ACS355 drives with IP66/67 / UL Type 4x enclosure
More informationInstallation manual. Generator Paralleling Controller GPC multi-line 2 4189340225C
Installation manual Generator Paralleling Controller GPC multi-line 2 Software ver. 1.3X Compact system in one unit - dynamic synchronisation - load sharing - generator protection DEIF A/S 3-phase AC RMS
More informationJ1000. System configuration
YASKAWA JZ J1000 The basic inverter V/f controlled inverter Good torque performance (150% / 3 Hz) Double rating ND 120%/1min and HD 150%/1 min Overload detection function (150% during 60s) thermal function
More informationFrequency Converter Fv
2 Bosch Rexroth AG Electric Drives and Controls Documentation Brake chopper with up to 30 kw continuous braking power Easy to operate and service (detachable fan, LCD operating panel with copy function)
More informationUser manual. MODBUS-RTU SV-iC5. LG Industrial Systems
User manual MODBUS-RTU SV-iC5 Read this manual carefully before installing, wiring, operating, servicing or inspecting the drive. Keep this manual within easy reach for quick reference. LG Industrial Systems
More informationTURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES
SED-635 Digital Excitation System SED-635 is a complete excitation system capable of adapting to control synchronous generators of any size. The integration of the TOUCH SCREEN operator interface and a
More informationGE Industrial Solutions ASTAT BP. User Manual
GE Industrial Solutions ASTAT BP User Manual 1 GE Industrial Solutions 2013 GE Company All Rights Reserved WARNINGS 1. DISCONNECT POWER BEFORE INSTALLING OR SERVICING. 2. HAZARDOUS VOLTAGES ARE PRESENT
More informationABB HVAC Drives ACH400 Vertical Electronic Bypass to ACH550 E-Bypass, 1-25Hp @ 208V, 1-50Hp @ 480V (R1... R4 Frame Size Drives)
ABB HVAC Drives ACH400 Vertical Electronic Bypass to ACH550 E-Bypass, 1-25Hp @ 208V, 1-50Hp @ 480V (R1... R4 Frame Size Drives) Retrofit Guide PRODUCTS ACH400 to ACH550 Drive Replacement Instructions This
More informationREGAL-BELOIT. Installation and Operation Manual. Variable Speed AC Motor Drives. Micro and PowerWash Series
REGAL-BELOIT Variable Speed AC Motor Drives Micro and PowerWash Series Installation and Operation Manual Manual Number: SB184 TABLE OF CONTENTS 1.0 GENERAL................................................1
More informationCPW Current Programmed Winder. Application Handbook. Copyright 2002 by Eurotherm Drives, Inc.
CPW Current Programmed Winder Application Handbook Copyright 2002 by Eurotherm Drives, Inc. All rights strictly reserved. No part of this document may be stored in a retrieval system, or transmitted, in
More informationNTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter
NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter Description: The NTE2053 is a CMOS 8 bit successive approximation Analog to Digital converter in a 20 Lead DIP type package which uses a differential
More informationBT300 HVAC Drives Conventional Bypass (C-Bypass) Options
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC
More informationSECTION 26 29 23 VARIABLE FREQUENCY DRIVES
SECTION 26 29 23 VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 SCOPE A. Furnish and install individual freestanding variable frequency AC drives (VFD) as shown on the Drawings and specified herein. 1.02
More informationReliance Electric GV3000/SE Industrial AC Drive
Reliance Electric GV3000/SE Industrial AC Drive Multi-Purpose variable speed control of 1-400 HP three-phase motors, with Volts/Hertz or Vector mode operation as standard FLEXIBLE Control Whether you need
More informationYASKAWA AC Drive A1000
YASKAWA AC Drive A1000 Crane Software Application Manual Software No. VSA90507X Type: CIMR-AC Models: 200 V Class: 0.4 to 110 kw (1.2 to 160 kva) 400 V Class: 0.4 to 300 kw (1.4 to 460 kva) To properly
More informationSPEEDMASTER MICRO SERIES COMPACT INVERTERS
SPEEDMASTER MICRO SERIES COMPACT INVERTERS Installation and Operation Manual EC Declaration of Conformity TABLE OF CONTENTS 1.0 GENERAL....................................................... 2 PRODUCT
More informationMSN 70. Streç Film & Alüminyum Folyo Sarým Makinesi. Kullanma Kýlavuzu. Mertsan. Makine San. Tic. Ltd.Þti.
MSN 70 Streç Film & Alüminyum Folyo Sarým Makinesi Kullanma Kýlavuzu Mertsan Makine San. Tic. Ltd.Þti. Tel : + 90 212 550 42 62 Gsm : +90 542 432 17 03 Web : http://www.mertsanmakine.com e-mail : info@mertsanmakine.com
More informationTOSVERT VF-MB1. Functions for lift application
TOSVERT VF-MB1 Functions for lift application The technical information in this manual is provided to explain the principal functions and applications of the product, but not to grant you a license to
More informationABB machinery drives. User s manual ACS355 drives
ABB machinery drives User s manual ACS355 drives List of related manuals Drive manuals and guides ACS355 user s manual ACS355 drives with IP66/67 / UL Type 4x enclosure supplement ACS355 quick installation
More informationSAFETY INSTRUCTIONS. Always follow safety instructions to prevent accidents and potential hazards from occurring.
Thank you for purchasing LS Variable Frequency Drives! SAFETY INSTRUCTIONS Always follow safety instructions to prevent accidents and potential hazards from occurring. In this manual, safety messages are
More informationFractional to 2 HP DC Drives for Both Non-Regenerative and Regenerative Applications
DC3 DC Drives Fractional to 2 HP DC Drives for Both Non-Regenerative and Regenerative Applications The Reliance Electric DC3 family of drives provides cost-effective variable speed control and operates
More informationNumber 1 in efficiency
PowerXL DE1 Variable Speed Starter www.eaton.eu/de1 Number 1 in efficiency The easiest way of variable motor speed NEW Variation DE11 The new device category! The PowerXL DE1 Variable Speed Starter Why
More informationRVS-DXM Instruction Manual
RVS-DXM Digital Soft Starter with Internal ByPass 210-1100A, 208-600V Instruction Manual Ver. 06/02/2012 2 Table of content RVS-DXM Instruction Manual 1. TABLE OF CONTENT 1. Table of content... 2 2. Safety
More informationLG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
More informationBulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
More informationOperational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives
DOCUMENT: ECSEQ6-0 EFFECTIVE: 09/23/10 SUPERSEDES: Operational Overview and Controls Guide Two or Three Pump IronHeart Lite with Variable Frequency Drives 6700 Best Friend Road. Norcross, GA 30071. (770)
More informationAugust 2004. www.danahermotion.com SECO DC DRIVES. Table of Contents
SECO DC DRIVES SECO AC/DC DC Drives DRIVES Table of Contents August 2004 www.danahermotion.com Tel : 800 554 8466 Web site : www.danahermotion.com Mechanical and Electro-Mechanical Product Solutions by
More informationEFC 3600. Frequency converters
2 Bosch Rexroth AG Electric Drives and Controls Documentation Compact and complete: space saving side-by-side assembly, plug-in I/O terminals, with brake chopper and mains filter for ultra-simple installation
More informationHow To Use The Vacon 0 Machinery
vacon 0 machinery how would you like your ac drive today? easy adaptation for customer requirements The Vacon 0 Machinery is an extremely compact AC drive for machine builders in the power range from 0.25
More informationAltivar 212. Variable speed drives for asynchronous motors. Programming Manual 09/2011. www.schneider-electric.com S1A53838
Altivar 22 Variable speed drives for asynchronous motors Programming Manual 9/2 SA53838 www.schneider-electric.com The information provided in this documentation contains general descriptions and/or technical
More informationThe HVAC SOLUTION DELIVERING POWER...SAVING ENERGY
The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY PowerGate - Cost effective solutions for F 1 Horsepower Rating 001 1-40 HP (208V) 075 1-75 HP (480V) Input Voltage 2V 208-240V 4V 380-480V Disconnect
More informationWJ200 series Pursuing the Ideal Compact Inverter
WJ200 series Pursuing the Ideal Compact Inverter X200 series Simple, Trip-suppression and Eco-friendly Compact Inverter NE-S1 series Economical Inverter with Simple Operation L700 series Inverter designed
More informationInstallation & Operation Manual Dial-A-Flow Adjustable Frequency Drives
GM 04-13 Installation & Operation Manual Dial-A-Flow Adjustable Frequency Drives for 1/8 HP thru 1HP 3-Phase AC Motors rated 208 230 VAC, 50 & 60 Hz NEMA-1 / IP-40 Operates from 115 and 208/230 Volt 50/60
More informationApplication Note AN-SERV-006
THIS INFORMATION PROVIDED BY AUTOMATIONDIRECT.COM TECHNICAL SUPPORT IS SUPPLIED "AS IS", WITHOUT ANY GUARANTEE OF ANY KIND. These documents are provided by our technical support department to assist others.
More informationMC1000 Series Installation and Operation Manual
MC1000 Series Installation and Operation Manual NOTE! The manual covers software version M108314 and above. Refer to parameter 63 for the software version of the drive you are working with. If you are
More informationvacon x series rugged drives for the real world
vacon x series rugged drives for the real world 1 the toughest ac drives on the planet! The and X5 AC Drives are designed for REAL world that is not gentle or forgiving to electronic products. They have
More informationSmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings
Smart Frame Wiring Diagrams and Dimensional Drawings Smart Frame Size 60 Vac:.5-7.5 HP 08/0 Vac: 0.75- HP SPECIFICATION DATA CONTENTS Smart Frame Wiring Diagrams... Frame, Fused Disconnect Wiring Diagrams...
More informationNC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
More informationRVS-DX Instruction Manual
RVS-DX Digital Soft Starter with internal ByPass 8-1100A, 220-690V Instruction Manual Ver. 27/02/2009 2 Table of content RVS-DX Instruction Manual 1. TABLE OF CONTENT 1. Table of content...2 2. Safety
More informationOrdering Part Numbers:
TECHNICAL DATASHEET #TDAX021500 HYDRAULIC FAN CONTROLLER Application Platform 3 erature Sensors 4 Digital Command Interfaces 1 PWM Input and 1 Analog Input 1 Proportional or ON/OFF Current Output RS232
More informationAutomatic start of a generator
Automatic start of a generator General description This application note will help you to set your Xtender for an automatic start of a generator as per different parameters such as the output power, the
More informationBulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
More informationInstall the DeviceNet Module using the following procedure:
Installation INSTALLATION INSTRUCTIONS: MCD DEVICENET MODULE Order Code: 175G9002 1. Installation Install the DeviceNet Module using the following procedure: 1. Remove control power and mains supply from
More informationImpulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations
Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations Addendum to: IMPULSE G+ Series 3 Manual (140-10258) IMPULSE VG+ Series 3 Manual (140-10257) This addendum should be used when a 24VDC
More information3753 en - 04.2004/b VE/B - VE/RG Va V riable speed drives
3753 en 04.2004/b Variable speed drives LEROYSOMER's drives provide SPEED VARIATION for a DC motor, SIMPLY and ECONOMICALLY from a singlephase power supply. CMStype technology is used. These products conform
More informationInstallation & Operation Manual for Energenics Air-Flow Optimizer
1470 Don Street Naples, Florida 34104 Telephone: (239) 643-1711 Fax: (239) 643-6081 Customer Service: (800) 944-1711 Installation & Operation Manual for Energenics Air-Flow Optimizer Table of Contents
More informationSTARVERT ig5a. Compact & Powerful Inverter. 0.4~7.5kW 3Phase 200~230Volts 0.4~7.5kW 3Phase 380~480Volts. Automation Equipment
Leader in Electrics & Automation STARVERT iga Compact & Powerful Inverter.4~7.kW 3Phase 2~23Volts.4~7.kW 3Phase 38~48Volts Automation Equipment Inverter STARVERT iga LS Starvert iga is very competitive
More informationACS800. Master/Follower Application Guide Supplement to Firmware Manual for ACS800 Standard Application Program
ACS800 Master/Follower Application Guide Supplement to Firmware Manual for ACS800 Standard Application Program Master/Follower Application Guide Supplement to Firmware Manual ACS800 Standard Application
More informationSierra Dual 24 Volt Brushless DC Motor Controller Product Specification
Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification Assembly 025A0215 600A0942 Rev. A May 14, 2012 025A0215 Brushless DC Motor Controller Page 1 Revision History ECN # Date Rev Description
More informationDNP Points List and Implementation
S&C Electric Company BankGuard Plus DNP Points List and Implementation This appendix describes the DNP points and DNP implementation for the BankGuard PLUS Control, using software UPPD106S. DNP Points
More informationHITACHI INVERTER SJ/L100/300 SERIES PID CONTROL USERS GUIDE
HITACHI INVERTER SJ/L1/3 SERIES PID CONTROL USERS GUIDE After reading this manual, keep it for future reference Hitachi America, Ltd. HAL1PID CONTENTS 1. OVERVIEW 3 2. PID CONTROL ON SJ1/L1 INVERTERS 3
More informationFan Coil EC Motor Control
Fan Coil EC Motor Control G3 PWM BARD The Enviro-Tec Generation 3 PWM (G3 PWM) board provides a pulse-width modulated (PWM) signal to the EC motor to control fan speed. The board is factory programmed
More informationVLT AutomationDrive for Marine winch applications
MAKING MODERN LIVING POSSIBLE VLT APPLICATION NOTE VLT AutomationDrive for Marine winch applications This Application note is meant to be a guideline for using Danfoss VLT AutomationDrive in winch applications.
More information2011 Industrial Catalog. DRIVES, PAC, PLCs. Industrial Catalog 2011. www.toshiba.com/ind
www.toshiba.com/ind 2011 Toshiba International Corporation Rev. 110504 Industrial Catalog 2011 13131 W. Little York Road Houston, TX 77041 Tel: 713-466-0277 Fax: 713-466-8773 US: 800-231-1412 Canada: 800-872-2792
More informationOperational Overview and Controls Guide
DOCUMENT: ECSEQ2-1 EFFECTIVE: 02/14/07 SUPERSEDES: 02/26/03 Operational Overview and Controls Guide Standard Two or Three Pump Type VFD Booster Controls 6700 Best Friend Road. Norcross, GA 30071. (770)
More informationEmotron VSA Variable Speed Drive
Emotron VSA Variable Speed Drive Instruction manual English Quick Start Guide This guide is designed to assist in installing and running the variable speed drive to verify that the drive and motor are
More informationSafe Torque Off Option (Series B) for PowerFlex 40P and PowerFlex 70 Enhanced Control AC Drives
User Manual Safe Torque Off Option (Series B) for PowerFlex 40P and PowerFlex 70 Enhanced Control AC Drives Catalog Number 20A-DG01 Topic Page General Description 2 What Is the DriveGuard Safe Torque Off
More informationSMC FLEX QUICK START BULLETIN 150
QUICK START SMC FLEX BULLETIN 0 This guide provides you with the basic information required to start up your SMC Flex controller. When reading this document, look for this symbol Step x to guide you through
More informationHVAC03C2 HVAC61C2 HVAC03C5 HVAC61C5 NXL HVAC INVERTERS
HVAC03C2 HVAC61C2 HVAC03C5 HVAC61C5 NXL HVAC INVERTERS SPECIFICATIONS PRODUCT DATA Mains Connection Input voltage U in 380 500 Vac (±10%), 3~ Input Frequency 45 66 Hz Connection to mains Once per minute
More informationController Automation, Model II+
Controller Automation Page 2 of 2 Automation with the RADAK II+ power controller II+ I/O Points: Inputs 5 Programmable Digital inputs 2 Dedicated digital inputs (Channel select and External SCR control
More informationVS-606V7 Series Instruction Manual COMPACT GENERAL-PURPOSE INVERTER (VOLTAGE VECTOR CONTROL)
VS-606V7 Series Instruction Manual COMPACT GENERAL-PURPOSE INVERTER (VOLTAGE VECTOR CONTROL) PREFACE YASKAWA s VS-606V7 is such a small and simple inverter; as easy as using a contactor. This instruction
More informationBrushless DC Motor Controller Product Specification Assembly 025F0129
Brushless DC Motor Controller Product Specification Assembly 025F0129 September 16, 2009 025F0129 ST B Brushless DC Motor Controller Data Sheet Page 1 Revision History ECN # Date Rev Description By 07058
More information