Connecting the Console Port to a PC

Size: px
Start display at page:

Download "Connecting the Console Port to a PC"

Transcription

1 This document covers tasks associated with connecting a console port to a PC, and includes the following topics: Console (rollover) Cable and Adapters Making the physical connection Connecting using HyperTerminal Troubleshooting console port problems Console (rollover) Cable and Adapters A console cable kit is provided with your router. Use this kit when connecting your router to a PC or terminal. The console cable kit contains: RJ-45-to-RJ-45 console cable (blue) RJ-45-to-DB-9 adapter (gray) Table 1 describes the wiring for the console port, the console cable, and the included adapters. This table also includes pinouts for an RJ-45-to-DB-25 adapter. Table 1 Console Cable and Adapter Pinouts Console (DTE) Console Port Console Cable Adapter Adapter Terminal (DTE) Signal RJ-45 Pin RJ-45 Pin DB-9 Pin DB-25 Pin Signal RTS CTS

2 Console (DTE) Console Port Console Cable Adapter Adapter Terminal (DTE) Signal RJ-45 Pin RJ-45 Pin DB-9 Pin DB-25 Pin Signal DTR DSR TXD RXD GND GND GND GND RXD TXD DSR DTR CTS RTS You can identify a rollover cable by comparing the two modular ends of the cable. Hold the cable s ends side-by-side, with the tab at the back (pointing away from you). The wire connected to the pin on the outside of the left plug should be the same color as the wire connected to the pin on the outside of the right plug. (See Figure 1.) If your cable came from Cisco Systems, pin 1 is white on one connector, and pin 8 is white on the other (a rollover cable reverses pins 1 and 8, 2 and 7, 3 and 6, and 4 and 5).

3 Figure 1 Identifying a Rollover Cable Pin 1 on one connector and pin 8 on the other connector should be the same color. Pin 1 Pin 8 H10632 Making the physical connection The cable and adapters required for this connection are included with the router. Follow these steps to connect the router to a terminal or PC running terminal emulation software: Step 1 Locate the console port on the back of the router. Step 2 Connect the console (or rollover) cable to the console port on the router (see Figure 2). Note The console cable will need an RJ-45 to DB-25 adapter for Cisco 4000 and 7000 series routers. This adapter is supplied withthe router and is also included in your verikit.

4 Figure 2 Connecting to Console Port (1600 Series Router Shown) WIC OK OK Console port Rollover console cable (RJ-45-to-RJ-45) Step 3 Use the correct adapter to connect the other end of the cable to your terminal or PC. Note If your terminal or PC has a console port that does not fit one of the adapters, you must provide the correct adapter for that port.

5 Connecting using HyperTerminal Click on the HyperTerminal icon below to launch a pre-configured HyperTerminal connection. This connection is configured for use with all Cisco routers. (The router should be connected to your laptop at this time. If it is not, see.) Depending on your browser settings, you may initially see a message asking whether you want to open the file or save it to disk. To launch the connection now, select the "open" option. To save the connection to your local hard-drive for future use, select the "save" option. If you selected the "open" option, you should now be communicating with the router. If you are experiencing problems, make sure the router is powered on, you are attached to the proper Com Port and verify your cabling. Note You may want to save this HyperTerminal configuration file to your laptop or PC for future use. (Select File > Save as... from the HyperTerminal window menu.) Setting up a HyperTerminal connection file Using this procedure you will create a named connection that you can save and reuse. (This creates a connection identical to the one provided above, and is included primarily for your reference.)

6 To set up a HyperTerminal connection on your laptop: Step 1 Click the Start button on the Windows Taskbar, and select Programs > Accessories > HyperTerminal. The HyperTerminal folder appears. Step 2 Double-click Hypertrm.exe to initiate a new session. The Connection Description dialog box appears. Step 3 Type in a name and optionally select an Icon to represent your HyperTerminal session. Click OK. The Phone Number window appears. Step 4 Locate the Connect Using field near the bottom of the Phone Number window. Select Direct to COM1 from the drop-down list to indicate that this connection is a local session (and not a dial-up session). Click OK. The COM1 Properties window appears. Step 5 Step 6 Step 7 On the Port Settings tab, enter the following settings: Speed 9600 Data Bits 8 Parity none Stop bits 1 Flow Control none Click OK to make the connection. The COM1 Properties window disappears. You should now see a blinking cursor in the HyperTerminal terminal window. If there are any problems at this point, jump to Troubleshooting console port problems to isolate and fix the problem. From the HyperTerminal menu, select File > Save. This saves the Session for future use. The new named session appears in the HyperTerminal folder represented with the icon you chose in Step 3. (In the future, simply double-click this icon to open the saved connection.)

7 Step 8 Assuming you have already connected the router and laptop using a roll-over cable, you can verify that the session is active by pressing the Enter key on your laptop a couple of times. You should see the router prompt in the HyperTerminal window. Troubleshooting console port problems Symptom No connection. Check your laptop s settings to see if COM1 is loaded. Click on Start > Settings > Control Panel. Within the Control Panel window, open the Systems icon. Choose the Device Manager tab, and ensure that COM1 is an option on the Ports drop-down list. If COM1 is missing, reboot your laptop and repeat this check. It should now appear. Symptom No response from router once connected to router via console. Check to ensure you are using the correct cable (roll-over as opposed to straight through). Verify that HyperTerminal is configured to use the correct communications port. Symptom Only getting garbage from the router. Ensure HyperTerminal is setup using the correct speed 9600 Baud.

Cable Specifications and Information

Cable Specifications and Information APPENDIX A This appendix provides the connector and pinout information you need for making or purchasing cables used with Cisco VG224 voice gateway. To order cables from Cisco, see the Obtaining Technical

More information

Connectors and Cables

Connectors and Cables APPENDIX B This appendix describes the connectors, cables, and adapters that you use to connect the switch to other devices. Connector Specifications 10/100 Ports The 10/100 Ethernet ports use standard

More information

Connecting and Setting Up Your Laptop Computer

Connecting and Setting Up Your Laptop Computer CHAPTER 3 Connecting and Setting Up Your Laptop Computer This chapter explains how to connect your laptop to the Cisco Unified MeetingPlace system and how to set up your laptop so that you can use HyperTerminal.

More information

Cable Specifications and Information

Cable Specifications and Information APPENDIXA This appendix provides the connector and pinout information you need for making or purchasing cables used with Cisco VG350 Voice Gateway. To order cables from Cisco, see the Obtaining Technical

More information

Connector and Cable Specifications

Connector and Cable Specifications APPENDIXB This chapter describes the connector and cable specifications. Connector Specifications, page B-1l Cable and Adapter Specifications, page B-5 Connector Specifications 10/100/1000 Ports, page

More information

Cabling Guide for Console and AUX Ports

Cabling Guide for Console and AUX Ports Cabling Guide for Console and AUX Ports Contents Introduction Prerequisites Requirements Components Used Conventions Table of Routers with Console and AUX Ports Console Port Settings for Terminal Connection

More information

RJ45 Shielded (standard) port pinout. CS9000, Jetstream 4000 + 8500, Lanstream 2000, RTA8/RJX, RRC16, MTA8/RJX & SXDC8/RJX

RJ45 Shielded (standard) port pinout. CS9000, Jetstream 4000 + 8500, Lanstream 2000, RTA8/RJX, RRC16, MTA8/RJX & SXDC8/RJX Shielded (standard) port pinout Pin Circuit Function 1 DCD Input Data Carrier Detect 2 DSR Output Data Set Ready 3 DTR Input Data Terminal Ready 4 S/GND Signal Ground 5 TXD Output Transmit Data 6 RXD Input

More information

Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES

Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM COMMUNICATIONS WITH AN OCTOPUS. Article # 072297-1 Last reviewed: 03/25/98 Keywords: Serial Port, Modem, Polling, AquaWeb, Node Not Responding

More information

Cable Pinouts. SRP I/O Module

Cable Pinouts. SRP I/O Module Cable Pinouts C This appendix lists the cables and connector pinout assignments for the cables used with the ERX-700 series and ERX-1400 series. Topic Page SRP I/O Module C-1 CT1 and CE1 I/O Modules C-4

More information

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly

More information

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 1. Introduction Thank you for purchasing this 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter. It is an

More information

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version

More information

PCMCIA 1 Port RS232 2.1 EDITION OCTOBER 1999

PCMCIA 1 Port RS232 2.1 EDITION OCTOBER 1999 232 232232 PCMCIA 1 Port RS232 2.1 EDITION OCTOBER 1999 Guarantee. FULL 36 MONTHS GUARANTEE. We guarantee your interface card for a full 36 months from purchase, parts and labour, provided it has been

More information

CLEARONE DOCUMENT 801-000-002 (REVISION 1.0) October, 2008. with Converge Pro Units

CLEARONE DOCUMENT 801-000-002 (REVISION 1.0) October, 2008. with Converge Pro Units APPLICATION NOTES Converge Pro Products CLEARONE DOCUMENT 801-000-002 (REVISION 1.0) October, 2008. Troubleshooting USB Connections with Converge Pro Units Description This document explains how to connect

More information

Serial Cables & Adapters

Serial Cables & Adapters WTI Part No. 9 Rev. B Serial Cables & Adapters for WTI Products . Introduction This publication describes the serial cables and snap adapters that are used to connect your RSM-R series or MPC series unit

More information

Module Connectors and Cable Specifications

Module Connectors and Cable Specifications Module Connectors, page 1 Cables and Adapters, page 2 Cleaning the Fiber-Optic Connectors, page 6 Module Connectors RJ-45 Connector The RJ-45 connector is used to connect a Category 3, Category 5, Category

More information

Accessing Diagnostics using a Dialup Modem

Accessing Diagnostics using a Dialup Modem Purpose This application note is meant to guide a user through the setup and use of a dial-up modem to retrieve diagnostics data from a remote master. Equipment Used This application note was written specifically

More information

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server Products: EFA with EFA Scan, DVRM and DVMD with Realtime Monitor or Stream Explorer DVMD-B1 LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server Remote control of test and

More information

Cable Connection Procedures for Cisco 1900 Series Routers

Cable Connection Procedures for Cisco 1900 Series Routers CHAPTER 5 Cable Connection Procedures for Cisco 1900 Series Routers This document describes how to connect your Cisco 1941 integrated services router to a power source and to networks and external devices.

More information

Configuring the Switch with the CLI Setup Program

Configuring the Switch with the CLI Setup Program APPENDIXC Configuring the Switch with the CLI Setup Program This appendix provides a command-line interface (CLI) setup procedure for a standalone switch. To set up the switch by using Express Setup, see

More information

How to setup a serial Bluetooth adapter Master Guide

How to setup a serial Bluetooth adapter Master Guide How to setup a serial Bluetooth adapter Master Guide Nordfield.com Our serial Bluetooth adapters part UCBT232B and UCBT232EXA can be setup and paired using a Bluetooth management software called BlueSoleil

More information

VSCOM USB PRO Series Industrial I/O Adapters

VSCOM USB PRO Series Industrial I/O Adapters VSCOM USB PRO Series Industrial I/O Adapters 1.Introduction The VSCOM USB PRO Series Industrial I/O Adapters are advanced USB to Serial Adapters that connect to 1, 2, 4 or 8 RS-232/422/485 serial devices.

More information

Using HyperTerminal with Agilent General Purpose Instruments

Using HyperTerminal with Agilent General Purpose Instruments Using HyperTerminal with Agilent General Purpose Instruments Windows HyperTerminal can be used to program most General Purpose Instruments (not the 531xx series counters) using the RS-232 Serial Bus. Instrument

More information

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

ETHERNET WEATHER STATION CONNECTIONS Application Note 33 ETHERNET WEATHER STATION CONNECTIONS Application Note 33 With WeatherLink and a Device Server INTRODUCTION It is possible to substitute an Ethernet connection for the direct USB or serial connection that

More information

WHQL Certification Approval...2 User Interface...3 SUNIX s COMLab..4

WHQL Certification Approval...2 User Interface...3 SUNIX s COMLab..4 INDEX WHQL Certification Approval...2 User Interface....3 SUNIX s COMLab..4 1.0 Introduction...5 2.0 Specification..5 2.1 Features 2.2 Universal Serial PCI Card 2.3 RS-232 Specification 2.4 Low Profile

More information

RS-232 COMMUNICATIONS

RS-232 COMMUNICATIONS Technical Note D64 0815 RS-232 COMMUNICATIONS RS-232 is an Electronics Industries Association (EIA) standard designed to aid in connecting equipment together for serial communications. The standard specifies

More information

How To Connect A Directsofl To A Powerpoint With An Acd With An Ctel With An Dm-Tel Modem On A Pc Or Ipad Or Ipa (Powerpoint) With A Powerline 2 (Powerline

How To Connect A Directsofl To A Powerpoint With An Acd With An Ctel With An Dm-Tel Modem On A Pc Or Ipad Or Ipa (Powerpoint) With A Powerline 2 (Powerline Application Note Last reviewed: 03/17/2008 AN-KEP-003.doc Page 1 of 23 Introduction... 1 Recommended s and ports to use... 1 Cable Wiring... 2 MDM-TEL Configuration ( Wizard)... 3 Direct Logic Communications

More information

Maintaining the Content Server

Maintaining the Content Server CHAPTER 7 This chapter includes the following Content Server maintenance procedures: Backing Up the Content Server, page 7-1 Restoring Files, page 7-3 Upgrading the Content Server, page 7-5 Shutting Down

More information

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS MODEL ATC-2000 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2000 is a RS232/RS485 to TCP/IP converter integrated with a robust system and network management features designed

More information

TSX ETZ Configuration of your computer for TSX ETZ direct connection by serial link. Eng V1.0

TSX ETZ Configuration of your computer for TSX ETZ direct connection by serial link. Eng V1.0 TSX ETZ Configuration of your computer for TSX ETZ direct connection by serial link Eng V1.0 2 Table of Contents About the book.......................................5 Chapter 1 Configuration and connection

More information

How Do I Recover infiniti Remotes and Line Cards?

How Do I Recover infiniti Remotes and Line Cards? How Do I Recover infiniti Remotes and Line Cards? Date: June 26, 2008 Overview This FAQ contains the following information and procedures pertaining to ids Release 6.0.1 and later: Before Attempting to

More information

DIRECT INTERNET DATA. User s Guide

DIRECT INTERNET DATA. User s Guide DIRECT INTERNET DATA User s Guide Iridium Satellite LLC Rev. 2; June 15, 2001 DIRECT INTERNET DATA ------------------------------------------------------------------------------------- TABLE OF CONTENTS

More information

isco Connecting Routers Back to Back Through the AUX P

isco Connecting Routers Back to Back Through the AUX P isco Connecting Routers Back to Back Through the AUX P Table of Contents Connecting Routers Back to Back Through the AUX Ports...1 Introduction...1 Before You Begin...1 Conventions...1 Prerequisites...1

More information

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info RS232C < - > RS485 CONVERTER S MANUAL Model: LD15U INTRODUCTION Milestone s model LD-15U is a RS232 to RS 485 converter is designed for highspeed data transmission between computer system and or peripherals

More information

IP SERIAL DEVICE SERVER

IP SERIAL DEVICE SERVER IP SERIAL DEVICE SERVER ( 1 / 2 / 4 serial port ) Installation guide And User manual Version 1.0 1Introduction... 5 1.1Direct IP mode...5 1.2Virtual COM mode...5 1.3Paired mode...6 1.4Heart beat... 6

More information

DIAL-UP DATA. User s Guide

DIAL-UP DATA. User s Guide DIAL-UP DATA User s Guide Iridium Satellite LLC Rev. 5; January 1, 2003 DIAL-UP DATA SERVICE--------------------------------------------------------------------------------------- TABLE OF CONTENTS 1 Dial-Up

More information

Serial to Bluetooth Adapter

Serial to Bluetooth Adapter Serial to Bluetooth Adapter Serial (RS-232) to Bluetooth Class 1 Adapter ICRS232BT1 Actual product may vary from photo FCC Compliance Statement This equipment has been tested and found to comply with the

More information

Set Up E-mail Setup with Microsoft Outlook 2007 using POP3

Set Up E-mail Setup with Microsoft Outlook 2007 using POP3 Page 1 of 14 Help Center Set Up E-mail Setup with Microsoft Outlook 2007 using POP3 Learn how to configure Outlook 2007 for use with your 1&1 e-mail account using POP3. Before you begin, you will need

More information

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012 Quick Note 32 Using Digi RealPort with a Digi TransPort Router UK Support September 2012 1 Contents 1 Introduction... 3 1.1 Outline... 3 1.2 Assumptions... 3 1.3 Version... 3 2 Configuration & scenario...

More information

PC Program User s Guide (01.01.05) 1. Connecting the PC. 2. Installation and Start-up. 3. Programming

PC Program User s Guide (01.01.05) 1. Connecting the PC. 2. Installation and Start-up. 3. Programming Work Off-Line Set up a new database or modify a previously saved database (without being connected to the telephone system). This helps minimize on-site programming time. Work On-Line (connected directly

More information

Making a DB to RJ45 adapter.

Making a DB to RJ45 adapter. Making a DB to RJ45 adapter. DB9 to RJ45 adapters are often used in combination with a RS232 repeater for extending the distance of a serial RS232 link, but can be used for any adapter or converter purposes.

More information

Configuring Serial Terminal Emulation Programs

Configuring Serial Terminal Emulation Programs Configuring Serial Terminal Emulation Programs Table of Contents Configuring Serial Terminal Emulation Programs: An Introduction... 3 HyperTerminal... 3 Configuring HyperTerminal... 3 Tera Term Pro...

More information

Connecting the DG-102S VoIP Gateway to your network

Connecting the DG-102S VoIP Gateway to your network Contents of Package: DG-102S VoIP Station Gateway Power adapter CD-ROM, including User s Manual Quick Install Guide Requirements: RS-232 Console Cable Two RJ-45 CAT-5 Straight-Through Cables For more information

More information

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...

More information

PCLinq2 Hi-Speed USB Bridge-Network Cable. Quick Network Setup Guide

PCLinq2 Hi-Speed USB Bridge-Network Cable. Quick Network Setup Guide PCLinq2 Hi-Speed USB Bridge-Network Cable Congratulations! Quick Network Setup Guide For Windows 98/ME/2000/XP Congratulations for installing the PCLinq2 Hi-Speed USB Bridge-Network Cable. This Quick Network

More information

Using a Laptop Computer with a USB or Serial Port Adapter to Communicate With the Eagle System

Using a Laptop Computer with a USB or Serial Port Adapter to Communicate With the Eagle System Using a Laptop Computer with a USB or Serial Port Adapter to Communicate With the Eagle System ECU DB9 USB 20-060_A.DOC Page 1 of 18 9/15/2009 2009 Precision Airmotive LLC This publication may not be copied

More information

LBNP16312. RS-232/485/422 serial device server. User manual

LBNP16312. RS-232/485/422 serial device server. User manual Tu Sitio de Automatización! LBNP16312 RS-232/485/422 serial device server User manual Summarize-----------------------------------------------------------------------------14-3 Package checklist---------------------------------------------------------------------14-3

More information

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4 ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4 1 PURPOSE:... 1 2 CPM-4/CPM-2 COMPATIBILITY... 2 2.1 NETWORK CABLES... 2 2.2 FACTORY DEFAULT SETTINGS... 2 2.3 CHANGING THE RS-232 SERIAL PORT BAUD

More information

Connector and Cable Specifications

Connector and Cable Specifications APPENDIX B This appendix provides the following cabling and pinout information for the Cisco IAD1101 integrated access device: Console Port Signals and Pinouts Ethernet Connector Pinouts Analog Subscriber

More information

SecureLinx Spider Duo Quick Start Guide

SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo QUICK START GUIDE CONTENTS Overview... 2 What s In The Box... 3 Installation and Network Settings...

More information

XStream Remote Control: Configuring DCOM Connectivity

XStream Remote Control: Configuring DCOM Connectivity XStream Remote Control: Configuring DCOM Connectivity APPLICATION BRIEF March 2009 Summary The application running the graphical user interface of LeCroy Windows-based oscilloscopes is a COM Automation

More information

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL Rev. D PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL 10 BORIGHT AVENUE, KENILWORTH NEW JERSEY 07033 TELEPHONE: 800-524-0273 FAX: 908-686-9317 TABLE OF CONTENTS Page

More information

MS830 / MS833 Barcode Reader v1.0 9-December-2014

MS830 / MS833 Barcode Reader v1.0 9-December-2014 MS830 / MS833 Barcode Reader v1.0 9-December-2014 Publication Information 2014 Imagine Communications Corp. Proprietary and Confidential. Imagine Communications considers this document and its contents

More information

EnGenius ERB9250 300M Range Extender. Quick Start Guide

EnGenius ERB9250 300M Range Extender. Quick Start Guide EnGenius ERB9250 300M Range Extender Quick Start Guide Package Contents One ERB9250 300M Range Extender One 12V/1A power adapter Two 2dBi 2.4GHz SMA antennas One Ethernet cable One CD-ROM with user s manual

More information

DIRECT INTERNET 3. Install Guide for the Mac OS Operating System

DIRECT INTERNET 3. Install Guide for the Mac OS Operating System DIRECT INTERNET 3 Install Guide for the Mac OS Operating System Iridium Communications Inc. Rev. 1; October 15, 2010 Overview Iridium s Direct Internet Data Service allows customers to connect directly

More information

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide 2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide 1. Introduction Thank you for purchasing this 2-Port RS232/422/485 Combo Serial to USB Adapter.

More information

SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS. Quick Start Instructions

SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS. Quick Start Instructions TM SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS Quick Start Instructions Introduction WinLoad for Windows was developed to simplify and speed up the task of programming Paradox control panels. Remote

More information

3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T+ 485+ PIN6 T- 485- PIN7 R+ PIN8 R-

3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T+ 485+ PIN6 T- 485- PIN7 R+ PIN8 R- MODEL ATC-2004 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2004 is a 4 Port RS232/RS485 to TCP/IP converter integrated with a robust system and network management features

More information

Bluetooth to Serial Adapter

Bluetooth to Serial Adapter Bluetooth to Serial Adapter Third Edition, Oct 2007 Version 3.0 771-BTS1009C3-001 Contents 1.0 Features....P.2 2.0 Package Content....P.2 3.0 Hard Drives Requirement.P.2 4.0 Specifications.P.3 5.0 Pin

More information

How to setup a serial Bluetooth adapter

How to setup a serial Bluetooth adapter 2U www. How to setup a serial Bluetooth adapter Master Setup Guide For part numbers UCBT232B and UCBT232EXA UPairing the serial Bluetooth adapter with your computer UPairing with Windows 10.. 2U UPairing

More information

Quick-Start Guide 007-SE01-001. Gigaset. Residential Wireless Gateway SE567/SE568. Gigaset Communications GmbH is a trademark licensee of Siemens AG

Quick-Start Guide 007-SE01-001. Gigaset. Residential Wireless Gateway SE567/SE568. Gigaset Communications GmbH is a trademark licensee of Siemens AG Quick-Start Guide 007-SE01-001 Gigaset Residential Wireless Gateway SE567/SE568 Gigaset Communications GmbH is a trademark licensee of Siemens AG Before you begin... Verify that the following items came

More information

Application Note 2. Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP.

Application Note 2. Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP. Application Note 2 Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP. Reverse Telnet or Serial Terminal Server MultiTX feature UK Support March 2014 1 Contents

More information

Prestige 650R-31/33 Read Me First

Prestige 650R-31/33 Read Me First Prestige 650R-31/33 Read Me First Prestige Rear Panel Connections PORT DSL CONSOLE LAN 10/100M POWER Connect to a telephone jack using a telephone wire. CONNECTION Connect to a serial port (COM port) on

More information

DIAL-UP DATA. User s Guide

DIAL-UP DATA. User s Guide DIAL-UP DATA User s Guide Iridium Satellite LLC Rev. 2; June 15, 2001 DIAL-UP DATA SERVICE--------------------------------------------------------------------------------------- TABLE OF CONTENTS 1 Dial-Up

More information

Cable Specifications

Cable Specifications APPENDIX C Cable Specifications This appendix provides the following pinout information: Console Port Pinouts (RJ-45), Table C-1 Auxiliary Port Pinouts (RJ-45), Table C-2 EIA-530 DTE Cable Pinout (DB-60

More information

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification: PURPOSE Verify that communication is established for the following products programming option (488.2 compliant, SCPI only): DCS - M9C & DCS M130, DLM M9E & DLM-M9G & DLM M130, DHP - M9D, P series, SG,

More information

Guide to Installing BBL Crystal MIND on Windows 7

Guide to Installing BBL Crystal MIND on Windows 7 Guide to Installing BBL Crystal MIND on Windows 7 Introduction The BBL Crystal MIND software can not be directly installed on the Microsoft Windows 7 platform, however it can be installed and run via XP

More information

1.1 Connection. 1.1.1 Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking

1.1 Connection. 1.1.1 Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking POS function Marchen POS-DVR surveillance system is a professional surveillance integrated with POS system. By bringing video and POS transaction data together, the POS-DVR surveillance system provides

More information

ABB solar inverters. Installation and setup instruction Aurora Manager TL software and ABB PVI-USB-RS232_485 adapter

ABB solar inverters. Installation and setup instruction Aurora Manager TL software and ABB PVI-USB-RS232_485 adapter ABB solar inverters Installation and setup instruction Aurora Manager TL software and ABB PVI-USB-RS232_485 adapter Introduction This document details the procedure for the installation on a user s computer

More information

DUKANE Intelligent Assembly Solutions

DUKANE Intelligent Assembly Solutions PC Configuration Requirements: Configuration Requirements for ipc Operation The hardware and operating system of the PC must comply with a list of minimum requirements for proper operation with the ipc

More information

Communication with BushingGard using computer USB port

Communication with BushingGard using computer USB port Communication with BushingGard using computer USB port There are two ways of communication with BushingGard through computer USB port: Direct communication between computer USB port and BushingGard USB

More information

Palomar College Dial-up Remote Access

Palomar College Dial-up Remote Access Palomar College Dial-up Remote Access Instructions for Windows 95/98 and Windows 2000 Following are instructions to implement dialup access to the Palomar College network, email and Internet. The minimum

More information

NPort DE-311 Hardware Installation Guide

NPort DE-311 Hardware Installation Guide NPort DE-311 Hardware Installation Guide Fourth Edition, June 2008 www.moxa.com/product 2008 Moxa Inc., all rights reserved. Reproduction without permission is prohibited. NPort DE-311 Hardware Installation

More information

PM1122 INT DIGITAL INTERFACE REMOTE

PM1122 INT DIGITAL INTERFACE REMOTE PM1122 INT DIGITAL INTERFACE REMOTE PM1122 INT front panel description: 1. Clear wireless remotes knob: push this button for more than 2 seconds to clear the list of all assigned wireless remote settings

More information

M2M 3350 GSM/GPRS Modem User s Manual & Reference Guide Revision 1 June 2007

M2M 3350 GSM/GPRS Modem User s Manual & Reference Guide Revision 1 June 2007 M2M 3350 GSM/GPRS Modem User s Manual & Reference Guide Revision 1 June 2007 1999-2007 by Laipac Technology, Inc. All rights reserved The Specifications and information regarding the products in this manual

More information

Business Plus Accounting Hardware Setup Guide For Windows XP

Business Plus Accounting Hardware Setup Guide For Windows XP Business Plus Accounting Hardware Setup Guide For Windows XP 1 Contents Chapter 1 - Description of Computer Ports...3 Chapter 2 - Connecting Your Touch Screen...4 Chapter 3 Setting Up Your Printers In

More information

Inmarsat B Application Note

Inmarsat B Application Note This version cancels all previous versions Inmarsat B Application Note ISP BDE Internet AS S PC How to connect a Windows 95/98 workstation to an ISP AppNote 001/99 Dokumentnavn: RAMSATRVP24_DOC Udfærdiget

More information

ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION

ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is

More information

DSL Self-install Kit Instructions

DSL Self-install Kit Instructions DSL Self-install Kit Instructions Cover and installation notes Page 1 1. Verify your system requirements Page 2 2. Verify the contents of your DSL Self-Install kit Page 2 3. Install filters on your telephone

More information

Metasys System Direct Connection and Dial-Up Connection Application Note

Metasys System Direct Connection and Dial-Up Connection Application Note Metasys System Direct Connection and Dial-Up Connection Application Note Code No. LIT-1201639 Software Release 5.1 Issued August 27, 2013 Supersedes October 4 2010 Refer to the QuickLIT website for the

More information

SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2

SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2 SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2 USER MANUAL Rev. P1.11 September 13, 2006 DeltaV is a trademark of Emerson Process Management, Inc Emerson Process Management, Inc. 1998,

More information

Installing a Westell USB Network Adapter

Installing a Westell USB Network Adapter Installing a Westell USB Network Adapter Before You Begin Before you begin installing your Westell USB Network adapter: 1. Make sure the computer with the USB adapter meets the minimum system requirements

More information

Prestige 324 Quick Start Guide. Prestige 324. Intelligent Broadband Sharing Gateway. Version V3.61(JF.0) May 2004 Quick Start Guide

Prestige 324 Quick Start Guide. Prestige 324. Intelligent Broadband Sharing Gateway. Version V3.61(JF.0) May 2004 Quick Start Guide Prestige 324 Intelligent Broadband Sharing Gateway Version V3.61(JF.0) May 2004 Quick Start Guide 1 1 Introducing the Prestige The Prestige is a broadband sharing gateway with a built-in four-port 10/100

More information

Prestige 324. Prestige 324. Intelligent Broadband Sharing Gateway. Version 3.60 January 2003 Quick Start Guide

Prestige 324. Prestige 324. Intelligent Broadband Sharing Gateway. Version 3.60 January 2003 Quick Start Guide Prestige 324 Intelligent Broadband Sharing Gateway Version 3.60 January 2003 Quick Start Guide 1 Introducing the Prestige The Prestige is a broadband sharing gateway with a built-in four-port 10/100 Mbps

More information

Preparing the Computers for TCP/IP Networking

Preparing the Computers for TCP/IP Networking Configuration Preparing the Computers for TCP/IP Networking Configuring Windows 98, and ME for TCP/IP Networking Verifying TCP/IP Properties Configuring Windows 2000 or XP for IP Networking Install or

More information

Cisco 831 Router and Cisco SOHO 91 Router Cabling and Setup Quick Start Guide

Cisco 831 Router and Cisco SOHO 91 Router Cabling and Setup Quick Start Guide English CHAPTER 1 Cisco 831 Router and Cisco SOHO 91 Router Cabling and Setup Quick Start Guide Cisco One-Year Limited Hardware Warranty Terms Easy Installation: Try These Steps First! (CRWS Users) Overview

More information

Communications Instructions for DOOSAN, FANUC Controls

Communications Instructions for DOOSAN, FANUC Controls Communications Instructions for DOOSAN, FANUC Controls Ethernet & RS-232 for; 18i, 21i, 0ib and c 30i Series & 0id - 1 - Table of Contents Section 1... 3 Ethernet Set-up for the PC... 3 Description...

More information

Connecting to the Internet

Connecting to the Internet Connecting to the Internet Connecting the Gateway to the Internet Configuration of TCP/IP Protocol Installing the USB Drivers Connecting Ethernet Network Devices Connecting USB Network Devices Connecting

More information

SETTING UP A REMOTE MODEM CONNECTION Application Note 27

SETTING UP A REMOTE MODEM CONNECTION Application Note 27 SETTING UP A REMOTE MODEM CONNECTION Application Note 27 with WeatherLink for Windows Serial Version Only INTRODUCTION This document provides guidelines on how to set up a remote modem connection. This

More information

ScanWin Installation and Windows 7-64 bit operating system

ScanWin Installation and Windows 7-64 bit operating system ScanWin Installation and Windows 7-64 bit operating system In order to run the ScanWin Pro install and program on Windows 7 64 bit operating system you need to install a Virtual PC and then install a valid,

More information

USB 3.0 to Gigabit Ethernet Adapter

USB 3.0 to Gigabit Ethernet Adapter USB 3.0 to Gigabit Ethernet Adapter User Manual Ver. 1.00 All brand names and trademarks are properties of their respective owners. Contents: Chapter 1: Introduction... 3 1.1 Product Introduction... 3

More information

Schneider OS-Loader usage via Ethernet or USB.

Schneider OS-Loader usage via Ethernet or USB. LHC Gas Systems 28 th February, 2007 Schneider OS-Loader usage via Ethernet or USB. Jacques ROCHEZ - IT/CO/FE Abstract This document is a guideline on how to configure correctly a PC for the use of the

More information

Yale Software Library

Yale Software Library Yale Software Library http://www.yale.edu/its/software/ For assistance contact the ITS Help Desk 203-432-9000, helpdesk@yale.edu Two-factor authentication: Installation and configuration instructions for

More information

Business Wireless Internet quick install guide

Business Wireless Internet quick install guide Read me first Business Wireless Internet quick install guide Wi-Fi and email set-up instructions included Actiontec Wireless Gateway TELUS Internet account information Record your personal account information

More information

Vantage RADIUS 50. Quick Start Guide Version 1.0 3/2005

Vantage RADIUS 50. Quick Start Guide Version 1.0 3/2005 Vantage RADIUS 50 Quick Start Guide Version 1.0 3/2005 1 Introducing Vantage RADIUS 50 The Vantage RADIUS (Remote Authentication Dial-In User Service) 50 (referred to in this guide as Vantage RADIUS)

More information

Encore Controller to Router Connections

Encore Controller to Router Connections Encore Presentation System Encore Controller to Router Connections Contents: Scope... 2 EXT COMM Pinouts... 2 Cable Connection Straight Through... 3 Cable Connection Null Modem... 3 Lantronix Ethernet

More information

3.1 Connecting to a Router and Basic Configuration

3.1 Connecting to a Router and Basic Configuration 3.1 Connecting to a Router and Basic Configuration Objective This lab will focus on the ability to connect a PC to a router in order to establish a console session and observe the user interface. A console

More information

One Port Serial Server Users Manual Model ESP901, ESP901E

One Port Serial Server Users Manual Model ESP901, ESP901E One Port Serial Server Users Manual Model ESP901, ESP901E Documentation Number: ESP901-2303 International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350

More information

RS-232/422/485, Power over Ethernet

RS-232/422/485, Power over Ethernet IP-COM-M IP-COMi-M IP-COM-M PoE IP-COMi-M PoE RS-232 RS-232/422/485 RS-232, Power over Ethernet RS-232/422/485, Power over Ethernet Edition: September 2012 The computer programs provided with the hardware

More information

Running the R4 Software on a USB Port

Running the R4 Software on a USB Port Tech Note Running the R4 Software on a USB Port Like a lot of other engine management software programs that have been around for a while, the R4 program is designed to communicate through a 9-pin serial

More information