BOREHOLE SEALING IN A COAXIAL HEAT EXCHANGER BY BENTONITE TREATMENT
|
|
- Dwight Hunt
- 7 years ago
- Views:
Transcription
1 BOREHOLE SEALING IN A COAXIAL HEAT EXCHANGER BY BENTONITE TREATMENT Frank.B.Cruickshanks, Olof Andersson, James Bardsley Climate Change Division, Meteorological Service of Canada, 45 Alderney Drive, Dartmouth, Nova Scotia, B2Y 2N6, Canada SWECO VIAK AB, P.O. Box 286, SE ; Malmö, SWEDEN Earth Source Energy Systems Inc PO Box 531, Halifax Central, Halifax NS B3J 2R7 Frank.Cruickshanks@ec.gc.ca; olof.andersson@sweco.se; palmer@ns.sympatico.ca ABSTRACT To store cold only for direct cooling using Borehole Thermal Energy Storage technology requires more efficient Borehole Heat Exchangers (BHE) than the single or double U-pipes that are normally applied in these types of storage systems. A more cost effective (low thermal resistance) coaxial (concentric) borehole heat exchanger suitable for cooling without chiller machines has been tested in Halifax, Nova Scotia, Canada. Field tests were conducted to determine whether a borehole could be sealed with bentonite to make it water tight and suitable for coaxial type borehole heat exchanger i.e. no groundwater flux. The experiment is part of pre investigations needed for a full-scale pilot BTES cooling plant expected to be realised by the Department of National Defence, dockyard naval base on Halifax Harbour. INTRODUCTION In October of 2004, a borehole sealing experiment aimed at demonstrating that a borehole could be sealed tightly by using bentonite as a sealing medium (Bentonite is a natural clay mineral, derived from volcanic ash that will swell and gel in the borehole). The experiment also involved evaluating a given procedure for the bentonite treatment and to monitor and evaluate the efficiency of treatment. The experiment was part of the pre investigations needed for a full-scale demonstration BTES cooling plant expected to be realised for the Department of National Defence on the Halifax Harbour. BACKGROUND To store cold only using Borehole Thermal Energy Storage (BTES) technology requires more efficient Borehole Heat Exchangers (BHE) than the single or double U-pipes that are normally applied in these types of storage systems (Figure 1). Figure 1 Traditional U-Tube and Concentric Tube Heat Exchangers
2 A single U-pipe in a grouted borehole will typically have a thermal resistance that corresponds to 5-6 o C temperature differences between the rock and the heat carrier fluid in the U-pipe. A double U-pipe will reduce this loss of temperature quality to 3-4 o C. However, a coaxial pipe or tube will have an optimal thermal efficiency and cut the difference to 1-2 o C, since it allows the fluid to have a direct contact to the borehole wall. The efficiency differences are illustrated Figure 2. Figure 2 Thermal resistances for different kinds of BHE systems (2) In addition to the higher efficiency, potential advantages with a coaxial type BHE includes the possibly of having water without antifreeze as the heat carrier fluid, which will increase the capacity of the store in cooling and decrease the pumping cost, as water with antifreeze mixed in is more viscous than water alone. As compared to a U-Tube type configuration, the length of the borehole required to cover the same amount of cooling is greatly reduced. The boreholes can be drilled in a smaller diameter and to greater depths, which reduces drilling costs. To further improve the efficiency the inner part of the coaxial tube could be insulated. There are some draw-backs to using the coaxial BHE; most obvious is that the boreholes must be almost perfectly sealed to not allow the heat carrier to infiltrate into the rock. Some other disadvantages may include an increased cost for the coaxial tube (compared to single U-pipe), difficulties inserting the tube in a centralized position, a current lack of standard well top equipment and the limited availability of smaller diameter drilling equipment in Canada, say 114mm. EXPERIMENTAL OBJECTIVES The main objective with the sealing experiment was to demonstrate that a borehole could be sealed properly by using bentonite as a sealing medium (bentonite is a natural clay mineral, derived from volcanic ash that will swell and gel once it has been inserted into the borehole fractures).the experiment also involved evaluating a given procedure for the treatment and to
3 monitor and evaluate the efficiency of treatment. The experiment is regarded as part of pre investigations needed for a full-scale demonstration BTES cooling plant expected to be realised for the Department of National Defence in Halifax, Nova Scotia, Canada THE BOREHOLE AND GEOLOGY An existing borehole located in Armdale, Halifax was used to perform the bentonite sealing experiment. The borehole is 100 m deep and has a mm steel casing down to 6 m. The diameter of the open hole is mm. The borehole is drilled into an anticline in the Halifax Formation. A TV inspection performed prior to the experiment showed that the rock consists of fine-grained thin-bedded slate. The bedding is clearly of metamorphic origin and shows a low water yield, Figure 3. Figure 3 Geology of the Halifax Area and the Armdale and Dockyard Sites. EXPERIMENTAL SET-UP Arrangements were made to elongate the existing steel casing. A plastic coaxial borehole heat exchanger (BHE) was installed and a specially constructed high pressure well-top with inlet and outlet tubing and couplings was also installed (Figures 4a and 4b). For the treatment, a unit for grouting was used as well as a water tank with a volume of 1 m 3. A truck with back up water was available during the treatment and a vacuum-pump truck was brought to site for the disposal of bentonite slurry after treatment.
4 Figure 4a. Picture of principal experimental borehole configuration Figure 4b. Diagram of principal experimental borehole configuration TREATMENT PROCEDURE The grouting unit was first connected to the water tank and to the borehole inlet. The outlet from the borehole was connected to the water tank. Whereas the water tank was connected to the mixer to blend the slurry and the water that was replaced by slurry was disposed in the water tank (Figure 5). Figure 5 Experimental Set-up, the intake of the well is being connected to the grout pump
5 In the second step bentonite slurry was pumped down through the coaxial pipe to the bottom of hole, gradually replacing the water in the borehole with slurry. This procedure continued until returning water from the well started to show traces of slurry as a sign that it was filled to the surface. The slurry was mixed in a portion of 1/25 (1 kg bentonite to 25 l of water). All together 55 kg of bentonite were mixed with 1375 l of water. A high yield type of bentonite was used (Figure 6). The approximate properties of the mixture were 4% bentonite solids by weight and a viscosity of 8-9 centipoises. The slurry was pumped into the hole at a rate of some 50 l/minute and it took approximately 35 minutes to fill the borehole. Figure 6 A light bentonite slurry was blended in a mixer and then pumped into the borehole In the third step the slurry was circulated in the borehole for approximately 20 minutes with the highest flow rate possible. During this phase the slurry became homogenously mixed. In this circulation the smaller tanks on the grouting unit were used (Figure 7). Figure 7 Mixing of the slurry in the grout pump
6 During the process of pumping the borehole, pressure was noted on the supply pipe manometer (Figure 8). Borehole pressure went from being approximately 2.8 bars, at the end of pumping down the slurry, to 2.0 bars during the circulation process. In the fourth step the valve on the return pipe was gradually closed in order to pressurise the borehole. This stage lasted for 5 minutes and a maximum pressure of 6 bars was kept for another 5 minutes. Figure 8 A manometer on the inlet tube monitored the borehole pressure during the treatment process In the fifth step of the treatment, the slurry was replaced by water. The water was pumped through the borehole inlet and the slurry disposed of in a simple plastic container from where it was sucked to the tank on the vacuum truck (Figure 9). Figure 9 Thickened slurry being vacuum
7 The replacement of slurry with water took some 20 minutes of pumping and some 1500 l of water was used. After this time the "thicker" slurry was out of hole but another 2000 l of water was flushed through the system to clean the hole to a greater extent. At that time the return water was purposely slightly grey due to still remaining colloidal of clay minerals. In the sixth step of the procedure the borehole was placed under hydrostatic pressure in order to set the bentonite and to let residual bentonite provide further sealing. The inlet tube was connected to the city water (Figure10) and by a flow meter on the supply line the infiltration rate could be monitored. Figure10 The well is hooked up with the city water in order to finalise the sealing and to measure the tightness The hydrostatic pressure was set to 4 bars and was kept for 48 hours, but allowing a flow of water to the borehole to keep pressure up. Hence, the infiltration rate was measured. Readings of infiltration rate and pressure were taken at five occasions during this final stage of the experiment. TREATMENT EFFECT The injection capacity of the well before treatment was measured at 4 l/min, with an injection pressure of 0.2 bars. This corresponds to a specific capacity of 2 l/s x m. Immediately after the treatment, the specific capacity had dropped to 0.02 l/min showing an initial treatment factor of approximately 100. After three hours of injection, the injection capacity was down to (factor 160) and after 24 hours to (factor 330). At the final reading, 48 hours after treatment, the capacity was down to l/min x m representing a treatment factor of 400. This means that the well has a more than 400 times lower groundwater flow capacity after treatment than before.
8 CONCLUSIONS AND OBSERVATIONS The concept of using bentonite for sealing the borehole wall to an acceptable degree worked out as predicted. The sealing factor is in the order of 400, which makes the borehole water tight in practical terms. A learning lesson, partly unexpected, was that the borehole had to be under injection pressure for a longer period of time to reach the final clogging effect. However, this final setting of the bentonite is not labour intensive. The procedure for sealing using a grouting unit and a couple of water tanks also worked out as predicted. The operational time for the procedure with the equipment at the site was approximately 4 hours. By increasing the grout pump capacity, and by treating several boreholes in series, the time required to seal them could be reduced by a considerable amount. Theoretically, three to four times fewer boreholes i.e. less drilling will be required to store and retrieve energy from a cold store in the Halifax Formation slates using the concentric borehole design. ACKNOWLEDGEMENTS The Panel on Energy Research and Development (PERD) and Environment Canada, Atlantic Region, Climate Change Division, for funding and support. Bluenose Well Drilling Ltd. represented by Ralph Jacobs, for performance of sealing. REFERENCES 1. Andersson, Olof. Coaxial BHE Experiment in Halifax Canada (Borehole Sealing by Bentonite Treatment), Report Prepared for Environment Canada, Climate Change Division (Atlantic Region), Halifax, October Hellström, G, and Kjellsson, E. (2000). Laboratory measurements of heat transfer properties of different types of borehole heat exchangers. Proc. of Terrastock 2000, Stuttgart, Germany, August 28 September 1, 2000.
The ATES Project at Stockholm Arlanda Airport - Technical Design and Environmental Assessment
The ATES Project at Stockholm Arlanda Airport - Technical Design and Environmental Assessment O. Andersson SWECO Environment AB Box 286, 201 22 Malmö, Sweden Tel: +46 40 167214 olof.andersson@sweco.se
More information5.2. Vaporizers - Types and Usage
5.2. Vaporizers - Types and Usage 5.2.1. General Vaporizers are constructed in numerous designs and operated in many modes. Depending upon the service application the design, construction, inspection,
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationSolar Hot Water Heaters
Solar Hot Water Heaters Three High Vacuum Water inlet Stainless Steel screw Gel seal and insulation Water outlet Dust proof seals Non Pressure Models Details ASWH-1b ( Color Painted 304 ) ASWH-1c ( stainless
More information1 DESCRIPTION OF THE APPLIANCE
1 DESCRIPTION OF THE APPLIANCE 1.1 INTRODUCTION The cast iron SF boilers are a valid solution for the present energetic problems, since they can run with solid fuels: wood and coal. These series of boilers
More informationPERMEABILITY TEST. To determine the coefficient of permeability of a soil using constant head method.
PERMEABILITY TEST A. CONSTANT HEAD OBJECTIVE To determine the coefficient of permeability of a soil using constant head method. need and Scope The knowledge of this property is much useful in solving problems
More informationAlbert Złotkowski*, Patrycja Szczesiul** AN ANALYSIS OF A TEMPERATURE CHANGE IN A CROSS SECTION OF BOREHOLE HEAT EXCHANGER***
AGH DRILLING, OIL, GAS Vol. 30 No. 4 2013 http://dx.doi.org/10.7494/drill.2013.30.4.459 Albert Złotkowski*, Patrycja Szczesiul** AN ANALYSIS OF A TEMPERATURE CHANGE IN A CROSS SECTION OF BOREHOLE HEAT
More informationModel 1210C Battery Powered Pump Shown. Description
12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with
More informationTECHNICAL SPECIFICATIONS CEMENT-BENTONITE SLURRY TRENCH CUTOFF WALL
TECHNICAL SPECIFICATIONS CEMENT-BENTONITE SLURRY TRENCH CUTOFF WALL SCOPE This section of the specifications includes requirements for the Slurry Trench Cutoff Wall and related work as indicated on the
More informationSterile ReadyToProcess Hollow Fiber Cartridges Instructions for Use
GE Healthcare Instructions 28-9226-84 AD ReadyToProcess Sterile ReadyToProcess Hollow Fiber Cartridges Instructions for Use 1 Introduction... 1 2 Inspect the Cartridge... 1 3 General Description... 2 4
More informationHEAT PUMP FOR DISTRICT COOLING AND HEATING AT OSLO AIRPORT, GARDERMOEN
HEAT PUMP FOR DISTRICT COOLING AND HEATING AT OSLO AIRPORT, GARDERMOEN Geir Eggen 1 and Geir Vangsnes² 1) COWI AS. PB 254 Sentrum, N-7414 Trondheim. 2) Oslo Lufthavn AS, Edvard Munchsvei, 2 Gardermoen.
More informationNational Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction
More informationThermo Siphon Solar Systems
Thermo Siphon Solar Systems Thermo Siphon Solar Systems are a very cost effective way of producing hot water due to their simplicity in design and installation requirements. Usually more common in hotter
More informationPHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:
PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV
More informationThe HT BTES plant in Emmaboda
The HT BTES plant in Emmaboda Report from the first three years of operation 2010-2013 B. NORDELL A, A. LIUZZO SCORPO A,B, O. ANDERSSON C, L. RYDELL D A/ DIVISION OF ARCHITECTURE AND WATER, DEPT. CIVIL,
More informationUNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE 3211-4211 DOUBLE PIPE HEAT EXCHANGER
UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE 3211-4211 DOUBLE PIPE HEAT EXCHANGER OBJECTIVE Determine the Reynolds number for each flow. Determine the individual heat transfer
More informationZhao et al. 2.2 Experimental Results in Winter Season The analysis given below was based on the data collected from Nov. 2003 to Mar. 15, 2004.
Proceedings World Geothermal Congress 2005 Antalya, Turkey, 24-29 April 2005 A Case Study of Ground Source Heat Pump System in China Jun Zhao, Chuanshan Dai, Xinguo Li, Qiang Zhu and Lixin Li College of
More informationThermocline Management of Stratified Tanks for Heat Storage
Thermocline Management of Stratified Tanks for Heat Storage M.R.W. Walmsley, M. J. Atkins, J. Riley Energy Research Group, Department of Engineering, University of Waikato Hamilton, NZ Stratified tanks
More informationTRAINING AND EQUIPMENT MANUAL HOSE PRACTICES EFFECTIVE: OCTOBER 2007
TRAINING AND EQUIPMENT MANUAL HOSE PRACTICES 301.010 ANNUAL SERVICE TEST FOR FIRE HOSE EFFECTIVE: OCTOBER 2007 The Department will test all fire hose annually. The testing of fire hose determines its serviceability.
More informationQPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems
The Professional Choice in Fluid Management QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Olaer Group is a global player specialising in innovative, efficient system
More informationCOMPARISON OF DRILLING TECHNOLOGIES BETWEEN TOP DRIVE AND ROTARY TABLE IN GEOTHERMAL FIELDS: A CASE STUDY OF OLKARIA GEOTHERMAL FIELDS.
Proceedings 5 th African Rift geothermal Conference Arusha, Tanzania, 29-31 October 2014 COMPARISON OF DRILLING TECHNOLOGIES BETWEEN TOP DRIVE AND ROTARY TABLE IN GEOTHERMAL FIELDS: A CASE STUDY OF OLKARIA
More informationInitial Experiments of a Novel Liquid Desiccant Dehumidifier for Industrial and Comfort Air Conditioning Systems
Abstract Initial Experiments of a Novel Liquid Desiccant Dehumidifier for Industrial and Comfort Air Conditioning Systems M. Jaradat, R. Heinzen, U. Jordan, K. Vajen Kassel University (Germany), Institute
More informationSTANDARD SPECIFICATIONS SECTION 02959 SEWER MAIN AND LATERAL CONNECTION SEALING BY CHEMICAL GROUT
STANDARD SPECIFICATIONS SECTION 02959 SEWER MAIN AND LATERAL CONNECTION SEALING BY CHEMICAL GROUT PART 1 GENERAL 1.1 DESCRIPTION A. Section includes requirements for rehabilitation of defective mainline
More informationPLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:
PLATE HEAT EXCHANGER Installation Manual Customer Name: Serial number: Purchase order number: Project: Table of Contents ----------------------------------------------------------------- Page: 2 3 Name
More informationZenith Solar thermal 4.5m pump station Installation manual
Zenith Solar thermal 4.5m pump station Installation manual Product code: 20026145 INSTALLATION MANUAL WATER RETURN GROUP This instruction manual is an integral part of the installation and maintenance
More informationIndirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................
More informationOperators manual Basic water heater
Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,
More informationExploitation Tests of Borehole Heat Exchangers in the Laboratory of Renewable Energy Sources in Miekinia Poland
Proceedings World Geothermal Congress 2015 Melbourne, Australia, 19-25 April 2015 Exploitation Tests of Borehole Heat Exchangers in the Laboratory of Renewable Energy Sources in Miekinia Poland Jaroslaw
More informationAquifer Thermal Energy Storage Application in Greenhouse Climatization
Aquifer Thermal Energy Storage Application in Greenhouse Climatization Bekir TURGUT, Halime PAKSOY, Şaziye BOZDAĞ, Hunay EVLİYA, Kazım ABAK, H. Yildiz DASGAN Çukurova University 01130 Balcalı Adana-Turkey
More informationVisions become real. Temperature control and cooling systems. The innovative and reliable solution
Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature
More informationSunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
More informationHow To Use A Water Source Heat Pump
Geothermal Energy Using Water-Source Heat Pumps By VIRSTAR Corporation Geothermal Expertise Since 1978 All information contained herein is the exclusive property of VIRSTAR Corporation, all rights reserved.
More informationOptimizing Tank Cleaning Operations
Optimizing Tank Cleaning Operations Choosing the best way to thoroughly clean your tanks while minimizing use of costly chemicals, water and manual labor can be challenging. There are several things you
More informationWATER-SOURCE HEAT PUMPS*
CHAPTER 62, ARTICLE X, DIVISION 7. WATER-SOURCE HEAT PUMPS* * Editors Note: At the request of the county, Ord. No. 85-33, adopted Oct. 8, 1985, has been included in this Code. As the ordinance was not
More informationErgo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
More informationDetermination of Thermal Conductivity of Coarse and Fine Sand Soils
Proceedings World Geothermal Congress Bali, Indonesia, - April Determination of Thermal Conductivity of Coarse and Fine Sand Soils Indra Noer Hamdhan 1 and Barry G. Clarke 2 1 Bandung National of Institute
More informationREGISTRATION EXAMINATION, JUNE 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours
Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 99 REGISTRATION EXAMINATION, JUNE 009 PLUMBING INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time allowed THREE
More informationHEAT TRANSFER ENHANCEMENT ON DOUBLE PIPE HEAT EXCHANGER BY WIRE COILED AND TAPER WIRE COILED TURBULATOR INSERTS
HEAT TRANSFER ENHANCEMENT ON DOUBLE PIPE HEAT EXCHANGER BY WIRE COILED AND TAPER WIRE COILED TURBULATOR INSERTS J.Kalil basha 1,G.Karthikeyan 2, S.Karuppusamy 3 1,2 Assistant Professor, Dhanalakshmi Srinivasan
More informationMILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS
MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS May 29, 2013 Revision B Structural Guideline for Design and Installation Holes in Composite Floor Slab Terminal 3, Departure Level
More informationWater Volume Calculation in Hydronic Heating & Cooling Systems
Water Volume Calculation in Hydronic Heating & Cooling Systems Preface There are several methods which can be used to calculate the volume of water in a hydronic heating or cooling systems. However, these
More informationFLUID FLOW Introduction General Description
FLUID FLOW Introduction Fluid flow is an important part of many processes, including transporting materials from one point to another, mixing of materials, and chemical reactions. In this experiment, you
More informationWASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL
WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL Siniša Stojan, Ph.D. student Damir Dražić, Ph.D. student Brodotrogir, HR - 21220 Trogir, Croatia sinisa.stojan@brodotrogir.hr,
More informationTransformer oil cooler ALFA A02
A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using
More informationArt.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
More information3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow
1/6 RE 18309-3/06.10 Replaces: RE 18309-3/04.10 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z Description The flow control
More informationThe Central Solar Heating Plant with Aquifer Thermal Energy Store in Rostock - Results after four years of operation
The Central Solar Heating Plant with Aquifer Thermal Energy Store in Rostock - Results after four years of operation Thomas Schmidt 1), Hans Müller-Steinhagen 1)2)3) 1) Solar- und Wärmetechnik Stuttgart
More informationources of Drinking Water
The drop on water Sources of Drinking Water Did you know that 40 per cent of Nova Scotians get their water privately from a drilled well, a dug well, or a surface water source? The other 60 per cent rely
More informationCooling system components, removing and installing
Engine BHW Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! When doing any repair work, especially in the engine compartment,
More informationInstallation and Commissioning Manual Solar Stations FlowCon Max Evolution II
Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II 1 For your safety Table of Contents 1 For your safety... 3 1.1 About this manual... 3 1.2 Designated use... 3 1.3 Qualification
More informationA Cover HVAC ENERGY EFFICIENT
A Cover HVAC ENERGY EFFICIENT EQUIPMENT toolkit 1 CONTENTS AND PARTNERS 2 Introduction 3 equipment & processes 3 Optimise operating settings 2 upgrade equipment 4 Seal the building 5 Rearrange air conditioning
More informationLS 2540 SEWER LATERALS AND INSPECTION TEES
LS 2540 SEWER LATERALS AND INSPECTION TEES A. Summary B. Submittals C. Site Information D. Sewer Pipe and Fittings E. Lateral Locations F. Lateral Installation G. Inspection Tee Installation H. Removal
More informationENGINE COOLING SYSTEM
ENGINE COOLING SYSTEM 1988 Toyota Celica 1987-88 TOYOTA Engine Cooling Systems Celica DESCRIPTION The basic liquid cooling system consists of a radiator, water pump, thermostat, cooling fan, pressure cap,
More informationCalifornia Department of Transportation Doyle Drive Test Program Contract No. 04A3362
California Department of Transportation Doyle Drive Test Program Deep Soil Mixing (DSM) /Cutter Soil Mixing (CSM) Testing Report By Malcolm Drilling Company, Inc. 3524 Breakwater Ave., Suite 108 Hayward,
More informationEnergy Analysis and Comparison of Advanced Vapour Compression Heat Pump Arrangements
Energy Analysis and Comparison of Advanced Vapour Compression Heat Pump Arrangements Stuart Self 1, Marc Rosen 1, and Bale Reddy 1 1 University of Ontario Institute of Technology, Oshawa, Ontario Abstract
More information2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow
2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow RE 18309-64/04.10 1/6 Replaces: RE 00171/02.07 A-VRFC2C-VEI-VS-LS 0M.28.03.80 - Y - Z Description
More informationHydro International First Defense OK 110 Scour and Removal Efficiency Confirmation Tests November 9-10 2010
Hydro International First Defense OK 110 Scour and Removal Efficiency Confirmation Tests November 9-10 2010 Reported by James Houle UNH Stormwater Center On November 9-10, 2010, I witnessed scour and removal
More informationHeat Transfer Enhancement in a Heat Exchanger using Punched and V-cut Twisted Tape Inserts
Heat Transfer Enhancement in a Heat Exchanger using Punched and V-cut Twisted Tape Inserts Imran Quazi#1, Prof. V.R.Mohite#2 #1DPCOE-Mechanical Department, SPP University Pune, India imranqu azi198 7@gmail.com
More informationGround-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29
Ground-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29 A refrigerant retrofit project, involving the conversion of a large Data Room cooling system from R22 to R422D (DuPont
More informationGuidelines For Sealing Groundwater Wells
Guidelines For Sealing Groundwater Wells Government of Newfoundland and Labrador Department of Environment and Conservation Water Resources Management Division Government of Newfoundland and Labrador Department
More informationMAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT
Record MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT Abandoned Gravity Private Combined Gravity Private Foul Gravity Private Surface Water Gravity Public Combined Gravity Public Foul Gravity Public
More informationITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.
ITE Indirect calorifier ITE - 400/500/600/750/1000 0310 117 Installation, User and Service Manual Innovation has a name. Read this manual carefully Warning Read this manual carefully before starting the
More informationStainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
More informationGEOTHERMAL HEATING AND COOLING INTRODUCTION
GEOTHERMAL HEATING AND COOLING INTRODUCTION Geothermal Heating and Cooling Systems provide space conditioning -- heating, cooling, and humidity control. They may also provide water heating -- either to
More informationHeat. Investigating the function of the expansion valve of the heat pump. LD Physics Leaflets P2.6.3.2. Thermodynamic cycle Heat pump
Heat Thermodynamic cycle Heat pump LD Physics Leaflets P2.6.3.2 Investigating the function of the expansion valve of the heat pump Objects of the experiment g To study the operational components of the
More informationCDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)
CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive
More informationDesigning coaxial ground heat exchangers with a thermally enhanced outer pipe
Raymond et al. Geothermal Energy (2015) 3:7 DOI 10.1186/s40517-015-0027-3 RESEARCH ARTICLE Open Access Designing coaxial ground heat exchangers with a thermally enhanced outer pipe Jasmin Raymond 1*, Serge
More informationSeated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange
Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications. The
More informationSTEAM HEATING SYSTEM TROUBLESHOOTING GUIDE
Page 1 of 9 PURPOSE Steam is the most commonly used heating medium for maintaining process temperatures. Compared to other heating media, steam contains a significant amount of heat energy, and this heat
More informationMechanical shaft seal types and sealing systems
Chapter 2 Mechanical shaft seal types and sealing systems 1. Mechanical shaft seal types 2. Sealing systems 3. Selecting a mechanical shaft seal Mechanical shaft seal types and sealing systems 1. Mechanical
More informationimagine SOLAR AIR CONDITIONING MADE EASY
imagine SOLAR AIR CONDITIONING MADE EASY WHY SOLAR COOLING? Imagine...being able to fit a solar air conditioning system to your building that would result in dramatic reductions in electricity consumption
More informationAssembly and instructions
Assembly and instructions Franke Minerva 3-in-1 Kettle Tap Retain for reference NB: For use only with Franke Heating Tank INTRODUCTION The Kettle Tap is suitable for dispensing boiling water (100 C) and
More informationDrake Landing Solar Community
www.dlsc.ca Innovation. Drake Landing Solar Community The Drake Landing Solar Community (DLSC) is a master-planned neighbourhood of 52 homes in the Town of Okotoks, Alberta, Canada that has successfully
More informationGEET Fuel Processor Plans
GEET Fuel Processor Plans This is a greatly simplified Proof of Concept version of the GEET Fuel Processor that just about anyone can build from parts from a local Hardware store in a weekend for very
More informationHow to reduce the cure time without damaging the rubber compound during injection molding?
How to reduce the cure time without damaging the rubber compound during injection molding? 0Introduction This article aims at analyzing the rubber injection process and highlighting the limits that prevent
More informationA Selection Guide for DTL Series Heat Exchangers
A Selection Guide for DTL Series Heat Exchangers This is your guide to sizing and selecting DTL series heat exchangers. We recommend that you read this page completely before continuing to the step-by-step
More informationVisage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1
Visage Digital Digital diverter TM Installation guide Visage Digital diverter installation instructions Page 1 Visage Digital diverter Visage Digital concealed with adjustable and fixed head Visage Digital
More informationInstallation Manual Gravity Solar Water Heater Evacuated Tube Integrated (Direct) System, unpressurized
Installation Manual Gravity Solar Water Heater Evacuated Tube Integrated (Direct) System, unpressurized Gravity Solar System Installation Manual: This manual explains how to install a system of evacuated
More informationIntroduction. The following is an outline of the contents of this paper: Definition of Artificial Lift Page 2. How an Oil Well is Produced Page 2
Introduction Canadian Oilwell Systems Company and it s subsidiaries are suppliers of oil well Electric Submersible Pumping systems (ESPs). Such pumps are used to lift oil from oil wells so that the oil
More informationT A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A
T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test
More informationINSITU TESTS! Shear Vanes! Shear Vanes! Shear Vane Test! Sensitive Soils! Insitu testing is used for two reasons:!
In-situ Testing! Insitu Testing! Insitu testing is used for two reasons:! To allow the determination of shear strength or penetration resistance or permeability of soils that would be difficult or impossible
More informationTHE PSEUDO SINGLE ROW RADIATOR DESIGN
International Journal of Mechanical Engineering and Technology (IJMET) Volume 7, Issue 1, Jan-Feb 2016, pp. 146-153, Article ID: IJMET_07_01_015 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=7&itype=1
More informationHeavy Fuel Oil supply units. The world s best selling HFO supply unit. The right choice for any conditions
The world s best selling supply unit. The right choice for any conditions AB-c arine Compact Heavy Fuel Oil supply unit This series of marine AB-c Heavy Fuel Oil () supply units is developed to combine
More informationOil / Air Cooling Units for mechanical engineering and mobile hydraulics
Oil / Air Cooling Units for mechanical engineering and mobile hydraulics ViFlow Finland Oy Kauppakartanontie 7 A 1 00930 Helsinki, Finland tel. +358 40 178 0920 fax +358 9 4789 2800 viflow@viflow.fi www.viflow.fi
More informationMaking Your Home Ready For Solar Water Heating
Making Your Home Ready For Solar Water Heating During construction or a major renovation, making a home ready to use solar energy can be easy and inexpensive. When the time comes to install your solar
More informationDRAFT OF CDN S DEFLUORIDATION EXPERIENCES ON A COMMUNITY SCALE
DRAFT OF CDN S DEFLUORIDATION EXPERIENCES ON A COMMUNITY SCALE Written by Catholic Diocese of Nakuru, Water Quality 1 and Kim Müller 2 (Eawag) Reviewed by Peter Jacobsen 3 December 2006 1 Catholic Diocese
More informationOverheating limit control
Pahlén electric heater Maxi Heat with digital control is a compact and effective heater for swimming pools. It consists of a glassfibre reinforced polypropylene tank containing resistance-type heating
More informationThree main techniques are used to exploit the heat available: geothermal aquifers, hot dry rocks and ground-source heat pumps.
GEOTHERMAL ENERGY TECHNOLOGY DESCRIPTION Geothermal energy is the natural heat that exists within the earth and that can be absorbed by fluids occurring within, or introduced into, the crustal rocks. Although,
More informationHDA -----------------------------------------------------------
----------------------------------------------------------- Lightstrips ---------------------------------------------------------------------- Ceiling system for heating and cooling LIGHTSTRIPS LIGHTSTRIPS
More information08003-1 WATER SERVICE 2
08003_Mar08_2011.pdf Page 1 of 7 INDEX Page 08003-1 WATER SERVICE 2 1.1 Pipe 2 1.1.1 Copper 2 1.1.2 Polyethylene 2 1.2 Valves and Fittings 2 1.2.1 Main Stops 3 1.2.2 Curb Stops 3 1.2.3 Curb Box 3 1.2.4
More informationInnovation and Progress in Water Treatment Technology
Innovation and Progress in Water Treatment Technology Degree of separation of ultrafiltration Summary of the various processes The water will be pressed through the between the raw water side and the filtrate
More informationUnderstanding Plastics Engineering Calculations
Natti S. Rao Nick R. Schott Understanding Plastics Engineering Calculations Hands-on Examples and Case Studies Sample Pages from Chapters 4 and 6 ISBNs 978--56990-509-8-56990-509-6 HANSER Hanser Publishers,
More informationExperiment 3 Pipe Friction
EML 316L Experiment 3 Pipe Friction Laboratory Manual Mechanical and Materials Engineering Department College of Engineering FLORIDA INTERNATIONAL UNIVERSITY Nomenclature Symbol Description Unit A cross-sectional
More informationME 315 - Heat Transfer Laboratory. Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS
ME 315 - Heat Transfer Laboratory Nomenclature Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS A heat exchange area, m 2 C max maximum specific heat rate, J/(s
More informationPutting a chill on global warming
Carbon capture and storage Putting a chill on global warming SABINE SULZER SULZER PUMPS MARKUS DUSS SULZER CHEMTECH Whenever fuel is burned, carbon dioxide (CO ) is emitted into the atmosphere. The subsequent
More informationSTATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual
STATFlow Direct-to-Drain System For use with STATIM 2000 and STATIM 5000 Autoclaves Installation Guide and Operator s Manual STATFlow Installation Guide and Operator s Manual 95-113193 Rev 2.0. Copyright
More information2A.1 Features of Chiller Control Components... 104. 2A.3 Chilled-Water Supply Temperature Control... 107. 2A.4 Cooling-Water Supply Control...
Appendix 2A: Chiller Control Principles... 104 2A.1 Features of Chiller Control Components... 104 2A.2 Start-up and Shutdown... 105 2A.2.1 Start-up...105 2A.2.2 Shutdown...106 2A.3 Chilled-Water Supply
More informationGuidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters
Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters When water is heated, it naturally expands and allowance has to be made for this. Vented water heaters usually
More informationDEEPSEALSM SERVICE SOLUTIONS
DEEP WATER CHEMICAL SOLUTIONS DEEPSEALSM SERVICE SOLUTIONS (DEEP SEA ENGINEERING ASSURANCE LEADERSHIP) Solving challenges. Deepwater Solutions from Multi-Chem ABOUT HALLIBURTON Founded in 1919, Halliburton