TIPO DI MISURA MEASURING TYPE AC TRMS. Ingresso da accessorio separato (vedi pag.10.37) W, VAr. Input from accessory. Potenziometro Potentiometer

Size: px
Start display at page:

Download "TIPO DI MISURA MEASURING TYPE AC TRMS. Ingresso da accessorio separato (vedi pag.10.37) W, VAr. Input from accessory. Potenziometro Potentiometer"

Transcription

1 D INDICTORI DIGITLI 96x48 3 CIFRE 3 DIGITS 96x48 DIGITL METERS DTI TECNICI TECHNICL DT visualizzazione massima max indication ±999 frequenza di lavoro operating frequency Hz sovraccarico istantaneo istantaneous overload 10 ln, 2 n separazione galvanica galvanic insulation ingresso-alimentazione / input-aux. supply isolamento dielectric strenght 2 k - 50 Hz x 60 s TIPO DI MISUR MESURING TYPE IMPEDENZ IMPEDNCE Schemi inserzione vedere pag 5.30 Wiring diagrams see page 5.30 DTI PER L ORDINZIONE ORDERING INFORMTION 100 m 1,5 C m D98EXXXX m k 4 M D98EXXXX3 100 m 1,5 C TRMS ( % In) m D98ERXXX m ( % n) k 4 M D98ERXXX3 100 µ m 3 D98MXXXX m m m k 1 M D98MXXXX3 Hz Hz; 0,1 1kHz k 1 M D98FPXXXX3 W, r 1m 60 D98MMXXX301 D98MTCXXX Hz 4 k 4 M Giri/min Proximity NPN o PNP D98MTXXX3 RPM a.c.( trimmer ±20% ) 1 300; 4 k 4 M D98MTTXXX3 d.c. ( trimmer ±20% ) ± (1 300); 50 k 2 M D98MTDXXX3 D98OHMXXX3 D98RESXXX3 2 fili/wires D98MC2XXX C; C; PT100 3 fili/wires C; D98MC3XXX3 4 fili/wires a richiesta / on demand CRTTERISTICHE D PRECISRE - CHRCTERISTICS TO BE SPECIFIED Standard a.c. (±10%, 45 65Hz, 2,5) LIMENTZIONE UX. SUPPLY OLTGE richiesta con a.c. (±10%, 45 65Hz, 2,5) d.c. ( %, 1,5W) a.c./d.c. (2,5/1,5W) 20 60;

2 D INDICTORI DIGITLI 96x48 3 CIFRE + 0 FISSO 3 DIGITS + FIXED ZERO 96x48 DIGITL METERS DTI TECNICI TECHNICL DT visualizzazione massima max indication ±9990 frequenza di lavoro operating frequency Hz sovraccarico istantaneo istantaneous overload 10 ln, 2 n separazione galvanica galvanic insulation ingresso-alimentazione / input-aux. supply isolamento dielectric strenght 2 k - 50 Hz x 60 s TIPO DI MISUR MESURING TYPE IMPEDENZ IMPEDNCE Schemi inserzione vedere pag 5.30 Wiring diagrams see page 5.30 DTI PER L ORDINZIONE C C TRMS W, r. Giri/min RPM 100 m 1, m D98EXXXX m k 4 M D98EXXXX0 100 m 1,5 ( % In) m D98ERXXX m ( % n) k 4 M D98ERXXX0 100 µ m m m D98MXXXX m k 1 M D98MXXXX0 1m 60 D98MMXXX001 D98MTCXXX Hz 4 k 4 M Proximity NPN o PNP D98MTXXX0 a.c.( trimmer ±20% ) 1 300; 4 k 4 M D98MTTXXX0 d.c. ( trimmer ±20% ) ± (1 300); 50 k 500 k D98MTDXXX0 D98OHMXXX0 D98RESXXX0 ORDERING INFORMTION CRTTERISTICHE D PRECISRE - CHRCTERISTICS TO BE SPECIFIED Standard a.c. (±10%, 45 65Hz, 2,5) LIMENTZIONE UX. SUPPLY OLTGE richiesta con a.c. (±10%, 45 65Hz, 2,5) d.c. ( %, 1,5W) a.c./d.c. (2,5/1,5W) 20 60;

3 D INDICTORI DIGITLI 96x48 3½ CIFRE 3½ DIGITS 96x48 DIGITL METERS DTI TECNICI TECHNICL DT visualizzazione massima max indication ±1999 frequenza di lavoro operating frequency Hz sovraccarico istantaneo istantaneous overload 10 ln, 2 n separazione galvanica galvanic insulation ingresso-alimentazione / input-aux. supply isolamento dielectric strenght 2 k - 50 Hz x 60 s TIPO DI MISUR MESURING TYPE IMPEDENZ IMPEDNCE Schemi inserzione vedere pag 5.30 Wiring diagrams see page 5.30 DTI PER L ORDINZIONE ORDERING INFORMTION 100 m 1,5 C m D98EXXXX m k 4 M D98EXXXX5 100 m 1,5 C TRMS ( % In) m D98ERXXX m ( % n) k 4 M D98ERXXX5 100 µ m 3 D98MXXXX m m m k 1 M D98MXXXX5 Hz Hz; 0,2 2kHz k 4 M D98FPXXXX5 W, r. 1m 60 D98MMXXX501 D98MTCXXX Hz 4 k 4 M Giri/min Proximity NPN o PNP D98MTXXX5 RPM a.c.( trimmer ±20% ) 1 300; 4 k 4 M D98MTTXXX5 d.c. ( trimmer ±20% ) ± (1 300); 50 k 1 m D98MTDXXX5 D98OHMXXX5 D98RESXXX5 2 fili/wires D98MC2XXX C; C; PT100 3 fili/wires C; D98MC3XXX5 4 fili/wires a richiesta / on demand CRTTERISTICHE D PRECISRE - CHRCTERISTICS TO BE SPECIFIED Standard a.c. (±10%, 45 65Hz, 2,5) LIMENTZIONE UX. SUPPLY OLTGE richiesta con a.c. (±10%, 45 65Hz, 2,5) d.c. ( %, 1,5W) a.c./d.c. (2,5/1,5W) 20 60;

4 D INDICTORI DIGITLI 96x48 3½ CIFRE + 0 FISSO 3½ DIGITS + FIXED ZERO 96x48 DIGITL METERS DTI TECNICI TECHNICL DT visualizzazione massima max indication ±19990 frequenza di lavoro operating frequency Hz sovraccarico istantaneo istantaneous overload 10 ln, 2 n separazione galvanica galvanic insulation ingresso-alimentazione / input-aux. supply isolamento dielectric strenght 2 k - 50 Hz x 60 s D98EXXXXG () impostazione fondo scala full scale setting 0,200 2,00 20, ,250 2,50 25, ,300 3,00 30, ,400 4,00 40, ,500 5,00 50, ,600 6,00 60, ,750 7,50 75, ,800 8,00 80, ,000 10,00 100, ,200 12,00 120, ,250 12,50 125, ,500 15,00 150, ,600 16,00 160, ,999 19,99 199, D98M...G.. impostazione fondo scala full scale setting 0,150 1,50 15, ,200 2,00 20, ,250 2,50 25, ,300 3,00 30, ,400 4,00 40, ,500 5,00 50, ,600 6,00 60, ,750 7,50 75, ,800 8,00 80, ,000 10,00 100, ,200 12,00 120, ,500 15,00 150, ,999 19,99 199, D98EXXXXG (-k) impostazione fondo scala full scale setting 0,200 2,00 20, ,220 2,20 22, ,240 2,40 24, ,360 3,60 36, ,380 3,80 38, ,400 4,00 40, ,500 5,00 50, ,630 6,30 63, ,660 6,60 66, ,000 10,00 100, ,100 11,00 110, ,320 13,20 132, ,500 15,00 150, Schemi inserzione vedere pag 5.30 Wiring diagrams see page 5.30 TIPO DI MISUR MESURING TYPE C C C TRMS W, r. Giri/min RPM + - k Programmabile Programmable Programmabile Programmable IMPEDENZ IMPEDNCE su T/5 - on CT/5 30 m 600 diretto/direct 4 M su T/100 e T/110 on CT/100 and CT/110 D98EXXXXG 500 k D98EXXXXG 100 m 1, m D98EXXXX m k 4 M D98EXXXX1 100 m 1,5 ( % In) m D98ERXXX m ( % n) k 4 M D98ERXXX m 3 D98MMXXXG42 Programmabile ± 20m 3 D98MMXXXG20 Programmable ± k D98MXXXXG10 ± 60m 10 k D98MXXXXG µ m m m D98MXXXX m k 1 M D98MXXXX1 1m 60 D98MMXXX101 D98MTCXXX Hz 4 k 4 M Proximity NPN o PNP D98MTXXX1 a.c.( trimmer ±20% ) 1 300; 4 k 4 M D98MTTXXX1 d.c. ( trimmer ±20% ) ± (1 300); 50 k 500 k D98MTDXXX1 D98OHMXXX1 D98RESXXX1 DTI PER L ORDINZIONE ORDERING INFORMTION CRTTERISTICHE D PRECISRE - CHRCTERISTICS TO BE SPECIFIED Standard a.c. (±10%, 45 65Hz, 2,5) LIMENTZIONE a.c. (±10%, 45 65Hz, 2,5) UX. SUPPLY OLTGE d.c. ( %, 1,5W) richiesta con a.c./d.c. (2,5/1,5W) 20 60;

5 D INDICTORI DIGITLI 96x48 4½ CIFRE 4½ DIGITS 96x48 DIGITL METERS DTI TECNICI TECHNICL DT visualizzazione massima max indication ± aggiornamento lettura reading update 5/sec. segnalazione di fuori scala overrange indication display over classe di precisione accuracy class 0.2 (d.c.); 0.35 (a.c.) frequenza di funzionamento operating frequency Hz sovraccarico di breve durata instantaneous overload 10 ln, 2 n (1 sec.) isolamento insulation completo/full tensione di prova test voltage 4k, 50Hz, 60sec. prova impulsiva surge test 8k, 1.2/50microsec. connessioni connections a vite / screw, max 4 mmq/sqmm custodia in materiale self estinguishing grado di protezione morsetti protection for terminals IP20 costruzione a norme according to CEI-DIN-DE-IEC TIPO DI MISUR MESURING TYPE IMPEDENZ IMPEDNCE Schemi inserzione vedere pag 5.30 Wiring diagrams see page 5.30 DTI PER L ORDINZIONE ORDERING INFORMTION aux. supply voltage C C TRMS C/ W, r. Giri/min RPM 100 m 1, m D98EXXXX m k 600 k D98EXXXX6 100 m 1,5 ( % In) m D98ERXXX ,5 m ( % n) k 600 k D98ERXXX6 - Programmabile ±1, ±5, Programmable ±100, ±500 D98UXXXQU - Programmabile ±2m, ±20m, Programmable ±200m, ±2, ±20 D98MXXXQ µ 10 k m m 1 k 10 D98MXXXX ,5 m k 600 k D98MXXXX6 1m 1 k D98MMXXX601 D98MTCXXX Hz 4 k 4 M Proximity NPN o PNP D98MTXXX6 a.c.( trimmer ±20% ) 1 300; 1 k 300 k D98MTTXXX6 d.c. ( trimmer ±20% ) ± (1 300); 1 k 300 k D98MTDXXX6 D98OHMXXX6 D98RESXXX6 CRTTERISTICHE D PRECISRE - CHRCTERISTICS TO BE SPECIFIED Standard a.c. (±10%, 45 65Hz, 6) LIMENTZIONE UX. SUPPLY OLTGE richiesta con a.c. (±10%, 45 65Hz, 6) d.c. ( %, 1,5W) a.c./d.c. (4/1,5W) 20 60;

6 X INDICTORI DIGITLI 96x48 4½ CIFRE CON LLRMI 4½ DIGITS 96x48 DIGITL METERS WITH LRMS DTI TECNICI TECHNICL DT visualizzazione massima max indication ± aggiornamento lettura reading update 5/sec. segnalazione di fuori scala overrange indication display over classe di precisione accuracy class 0.2 (d.c.); 0.35 (a.c.) frequenza di funzionamento operating frequency Hz sovraccarico di breve durata instantaneous overload 10 ln, 2 n (1 sec.) numero allarmi alarms 2 (1 SPDT+1 SPST) portata contatti contacts rating 10, 250 C1 segnalazione intervento allarmi alarm intervention indication tramite/by LED tipo allarme alarm type prog. MIN / MX / OFF tipo di sicurezza safety type prog. normal / intrinsic (positive) ritardo intervento intervention delay prog. OFF o/or sec. isteresi hysteresis prog % isolamento insulation completo/full tensione di prova test voltage 4k, 50Hz, 60sec. prova impulsiva surge test 8k, 1.2/50microsec. connessioni connections a vite / screw, max 4 mmq/sqmm custodia in materiale self estinguishing grado di protezione morsetti protection for terminals IP20 costruzione a norme according to CEI-DIN-DE-IEC kg 0,400 Schemi inserzione vedere pag 4.7 Wiring diagrams see page 4.7 DTI PER L ORDINZIONE ORDERING INFORMTION aux. supply voltage TIPO DI MISUR MESURING TYPE IMPEDENZ IMPEDNCE 100 m 1,5 C m X98EXXXX m k 600 k X98EXXXX6 100 m 1,5 C TRMS ( % In) m X98ERXXX ,5 m ( % n) k 600 k X98ERXXX6 C/ - Programmabile ±1, ±5, Programmable ±100, ±500 X98UXXXQU - Programmabile ±2m, ±20m, Programmable ±200m, ±2, ±20 X98MXXXQ µ 10 k m 50 X98MXXXX m 1 k ,5 m k 600 k X98MXXXX6 Hz Hz (2% 120% Un) k 4 M X96FPXXXX6 W, r. 1m 1 k X98MMXXX601 X98MTCXXX Hz 4 k 4 M Giri/min Proximity NPN o PNP X98MTXXX6 RPM a.c.( trimmer ±20% ) 1 300; 1 k 300 k X98MTTXXX6 d.c. ( trimmer ±20% ) ± (1 300); 1 k 300 k X98MTDXXX6 X98OHMXXX6 X98RESXXX6 CRTTERISTICHE D PRECISRE - CHRCTERISTICS TO BE SPECIFIED Standard a.c. (±10%, 45 65Hz, 6) LIMENTZIONE a.c. (±10%, 45 65Hz, 6) UX. SUPPLY OLTGE d.c. ( %, 1,5W) richiesta con a.c./d.c. (4/1,5W) 20 60;

7 D...MT... INDICTORI TCHIMETRICI PROGRMMBILI PROGRMMBLE TCHOMETERS DTI TECNICI TECHNICL DT frequenza di lavoro operating frequency Hz sovraccarico permanente continuous overload 1,2 n sovraccarico istantaneo istantaneous overload 2 n separazione galvanica galvanic insulation ingresso-alimentazione / input-aux. supply isolamento dielectric strenght 2 k - 50 Hz x 60 s TIPO - TYPE DIMENSIONI DIMENSIONS CIFRE DIGITS - 48 x D48MTTXXXG ac da alternatore tachimetrico 1, 2 o 3 ingressi: ac (alternator) 1, 2 or 3 inputs; x D76MTTXXXG 72 x D72MTTXXXG 96 x 48 3½ + 0 D98MTTXXXG 96 x 96 3½ + 0 D96MTTXXXG 48 x 48 3½ D48MTDXXXG Codice - code B C D E Peso - Weight D ,200 kg D ,200 kg D ,250 kg D ,250 kg D ,300 kg dc da dinamo tachimetrico 1, 2 o 3 ingressi: ±(1 300) dc (dinamo) 1, 2 or 3 inputs; ±(1 300) 72 x 36 3½ D76MTDXXXG 72 x D72MTDXXXG 96 x 48 3½ + 0 D98MTDXXXG 96 x 96 3½ + 0 D96MTDXXXG CRTTERISTICHE D PRECISRE - CHRCTERISTICS TO BE SPECIFIED Standard a.c. (±10%, 45 65Hz, 7) LIMENTZIONE UX. SUPPLY OLTGE richiesta con with extraprice utoalimentato - Self-supplied (70 120% n) a.c. (±10%, 45 65Hz, 7) d.c. ( %, 3W) a.c./d.c. (5/3W) 20 60; DTI PER L ORDINZIONE ingressi opzioni (vedi pag ) ORDERING INFORMTION s options (see page ) 5.27

8 D98P...3 COSFIMETRO DIGITLE INTEGRTO E LINERIZZTO INTEGRTED LINERIZED POWER FCTOR METER DTI TECNICI TECHNICL DT visualizzazione display 0,10-1,00-0,10 Indicazione CP o IND CP or IND tramite LED frontale / by frontal LED frequenza di lavoro operating frequency Hz sovraccarico istantaneo istantaneous overload 10 ln, 2 n segnalazione di fuori scala overrange indication punto lampeggiante / flashing dot separazione galvanica galvanic insulation ingresso-alimentazione / input-aux. supply isolamento dielectric strenght 2 k - 50 Hz x 60 s SITEM - SYSTEM INGRESSI - INPUTS - monofase single-phase trifase 3 fili carico equilibrato three-phase 3 wires balanced load trifase 4 fili carico equilibrato three-phase 4 wires balanced load 100: ingresso voltmetrico da precisare input voltage to be specified 1 5 ingresso amperomatrico da precisare input current to be specified D98PSXXXX3 D98PYXXXX3 D98PNXXXX3 CRTTERISTICHE D PRECISRE - CHRCTERISTICS TO BE SPECIFIED Standard a.c. (±10%, 45 65Hz, 7) kg 0,450 LIMENTZIONE UX. SUPPLY OLTGE richiesta con utoalimentato - Self-supplied (70 120% n) a.c. (±10%, 45 65Hz, 7) d.c. ( %, 3W) a.c./d.c. (5/3W) 20 60; D98PSXXXX3 D98PYXXXX3 DTI PER L ORDINZIONE ingressi D98PNXXXX3 ORDERING INFORMTION s 5.28

9 SCHEMI DI INSERZIONE INDICTORI DIGITLI E BRR LUMINOS WIRING DIGRMS DIGITL ND BR-GRPH METERS D48EXXXXG - D52EXXXXG D96EXXXXG - D98EXXXXG D96EXXXXG D98EXXXXG D96U... - D96M... D98U... - D98M... D48M... D52M... - D72M... D76M... - D96M... - D98M... D48E... D52E... - D72E... D76E... - D96E... - D98E... D48 /52 /72 /76 /96 /98MTT... D48 /52 /72 /76 /96 /98MTD... D48 /52 /72 /76 /96 /98MTC... D48 /52 /72 /76 /96 /98MT... D48 /52 /72 /76 /96 /98OHM... D48 /52 /72 /76 /96 /98RES... D48 /52 /72 /76 /96 /98MC2... D48 /52 /72 /76 /96 /98MC3... D48 /52 /72 /76 /96 /98MC4... D48 /52 /72 /76 /96 /98MCJ... D48 /52 /72 /76 /96 /98MCK... D48 /52 /72 /76 /96 /98MCR... D48 /52 /72 /76 /96 /98MCS... D48 /52 /72 /76 /96 /98MCT... B94M... B94E... D44M... D44E

Sensori induttivi conformi alle norme DIN 19234 CENELEC EN 50014-EN 50020 NAMUR (3) CARATTERISTICHE FEATURES. 2mm 3 24 Vdc 10%

Sensori induttivi conformi alle norme DIN 19234 CENELEC EN 50014-EN 50020 NAMUR (3) CARATTERISTICHE FEATURES. 2mm 3 24 Vdc 10% Interruttori di prossimità induttivi NON MPLIFICTI NMUR Sensori induttivi conformi alle norme DIN 34 TIPI - TYPES Ø 6,5 Ø 6,5 Ø 6,5 Ø8 Ø8 Ø6,5 Ø6,5 Ø6,5 M8x1 M8x1 NMUR SW13 SW13 CRTTERISTICHE FETURES Schermato

More information

Anelli Rings (1) (1) (2) (2) (3) TIPI - TYPES CARATTERISTICHE FEATURES. 1mm 3 24Vdc 10 30Vdc 10 30Vdc 10% 10% 200 ma.

Anelli Rings (1) (1) (2) (2) (3) TIPI - TYPES CARATTERISTICHE FEATURES. 1mm 3 24Vdc 10 30Vdc 10 30Vdc 10% 10% 200 ma. Interruttori di prossimità induttivi D NELLO Negli interruttori di prossimità ad anello il rilevamento avviene all interno dell anello stesso. Il campo di azione è regolabile mediante vite potenziometrica.

More information

MINI CONTATTORI / MINI CONTACTORS

MINI CONTATTORI / MINI CONTACTORS Informazioni generali / General information pag. 54 Caratteristiche tecniche / Technical datas pag. 57 Codici di ordinazione / Ordering product codes pag. 60 53 CONTTTORI TRIPOLRI CIRCUITO DI COMNDO C..

More information

INDICE MINI-CONTATTORI / CONTENTS MINI-CONTACTORS. Criteri di scelta pag. 1-48 Product selection. Caratteristiche tecniche pag. 1-51 Tecnical data

INDICE MINI-CONTATTORI / CONTENTS MINI-CONTACTORS. Criteri di scelta pag. 1-48 Product selection. Caratteristiche tecniche pag. 1-51 Tecnical data Indice Contents CONTROLLO MOTORE MOTOR CONTROL INDICE MINICONTTTORI / CONTENTS MINICONTCTORS Criteri di scelta pag. 8 Product selection Caratteristiche tecniche pag. Tecnical data 77 Criteri di scelta

More information

Serie ET / ET Series

Serie ET / ET Series Sensori di prossimità induttivi con campo di temperatura di lavoro esteso Extended working temperature range proximity inductive sensors Corpo in acciaio inox / stainless steel housing Modelli M12, M18

More information

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Panel Meters and Controllers Modular Panel Meter Type EDM 35 Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming

More information

SERIE FX3 e FX4 - FX3 and FX4 SERIES

SERIE FX3 e FX4 - FX3 and FX4 SERIES SERIE FX3 e FX - FX3 and FX SERIES SERIE FX3 e FX - FX3 AND FX SERIES SOMMARIO - INDEX AMPLIFICATORE PER FIBRA OTTICA DA GUIDA DIN SERIE FX3 E FX FIBER-OPTIC AMPLIFIER FOR DIN RAILS FX3 AND FX SERIES Elenco

More information

ISOMAG Millennium ML3F1 ESECUZIONE COMPATTA ML3F1 COMPACT EXECUTION

ISOMAG Millennium ML3F1 ESECUZIONE COMPATTA ML3F1 COMPACT EXECUTION M I S U R A T O R I E L E T T R O M A G N E T I C I D I P O R T A T A S E R I E E L E C T R O M A G N E T I C F L O W M E T E R S E R I E S ISOMAG Millennium CONVERTER MODEL M L 3 F 1 CONVERTITORE AD ALTA

More information

ELETTRONICA DUE FOTEK. Controlli di temperatura in logica fuzzy / Fuzzy temperature controller

ELETTRONICA DUE FOTEK. Controlli di temperatura in logica fuzzy / Fuzzy temperature controller * Controllo fuzzy + PID per la temperatura Fuzzy + Pid control * Metodo autotuning, impostabile al valore bias At bias value settable * Tipi di sonde : K J PT 100 Multi-input type K J PT selectable * Funzioni

More information

analog SENSORI INDUTTIVI ANALOGICI inductive analog sensors

analog SENSORI INDUTTIVI ANALOGICI inductive analog sensors Sensori di prossimità induttivi con uscita analogica Inductive proximity sensors with analogue output a Caratteristiche principali Main features > Ampia scelta di dimensioni: M, M2 e M > Wide choice of

More information

Strumenti digitali - Digital instruments SOMMARIO - INDEX

Strumenti digitali - Digital instruments SOMMARIO - INDEX - SOMMRIO - INDEX Tipo Type Pag. Page Tipo Type Pag. Page Caratteristiche tecniche Technical characteristics Strumenti digitali serie DR DR series Strumenti digitali DF 977 - DF D77 DF 977 - DF D77 Strumenti

More information

MHCO MHCO-RI. Transmitter The Transmitter, connected to the system, acquires the inputs and througth a fiber optic transmits it to the receiver.

MHCO MHCO-RI. Transmitter The Transmitter, connected to the system, acquires the inputs and througth a fiber optic transmits it to the receiver. -TVI -RI D.C. MEASURING CONVERTER Converter for D.C. Current and/or Voltage measurement. Direct connection to D.C. mains rating up to 4 kvcc. Fully isolated multi-voltage power suppy. Fiber optic connection

More information

SPECIFICA MATERIALE N. 571020. RESISTORE DI POTENZA AVVOLTO SU TELAIO METALLICO Mod. RDP600 POWER RESISTOR WOUND ON METALLIC FRAME 220 ±2 200-1+5

SPECIFICA MATERIALE N. 571020. RESISTORE DI POTENZA AVVOLTO SU TELAIO METALLICO Mod. RDP600 POWER RESISTOR WOUND ON METALLIC FRAME 220 ±2 200-1+5 N. 571 SPECIFICA MATERIALE Mod. RDP6 spessore 3 mm Approval Walter Cerutti Verified Mauro Pellegatta Revision 2 22/1/4 Emission DT 28.3.1997 Mod. RDP6 2 ±2-1+5 6 ±,3 8 ±,2 11 ±2 155 ±2 28 15 1. Potenza

More information

CATALOGO LED / LED CATALOGUE

CATALOGO LED / LED CATALOGUE ALED A Alimentatori elettronici per led IP. Uscita in corrente costante 350mA e 700mA. Classe II di isolamento contro scariche elettriche per contatto diretto ed indiretto. Protezione contro il cortocircuito,

More information

serie FX3 e FX4 - FX3 and FX4 series

serie FX3 e FX4 - FX3 and FX4 series serie FX3 e FX 26-0-200 10:08 Pagina 1 SOMMARIO - INDEX AMPLIFICATORE PER FIBRA OTTICA DA GUIDA DIN SERIE FX3 E FX FIBER-OPTIC AMPLIFIER FOR DIN RAILS FX3 AND FX SERIES Elenco delle caratteristiche funzionali

More information

M2M The measure of efficiency

M2M The measure of efficiency M2M The measure of efficiency The importance of control Measurement and advanced analysis of electrical parameters To make equipment as efficient as possible, it is essential to know the details of its

More information

Contenitori Enclosures

Contenitori Enclosures - 19 - Contenitori Enclosures Contenitori in materiale termoplastico per ausiliari di comando Ø 22 Thermoplastic enclosures suitable for control units Ø 22 Dati tecnici generali / General Technical Data

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

Short information Parameters are programmed via front-side membrane keypad

Short information Parameters are programmed via front-side membrane keypad Digital remote display for Flow Meter DM /DE Universal meter UZ Indication of the quantity consumed in m³ Features LED-Display 14.2mm red Indicating range -99999... 999999 0... 3 Decimal points programmable

More information

(PAG.1 / PAG.9) (PAG.10 / PAG.17) (PAG.18 / PAG.27) (PAG.28 / PAG.37) Serie dat5024/5028 series (PAG.38 / PAG.43) (PAG.44 / PAG.

(PAG.1 / PAG.9) (PAG.10 / PAG.17) (PAG.18 / PAG.27) (PAG.28 / PAG.37) Serie dat5024/5028 series (PAG.38 / PAG.43) (PAG.44 / PAG. Indice Product prodotti Index Convertitori Temperature di and temperatura signal e di converters segnale serie SLIM SLIM series (PAG.1 / PAG.9) Trasmettitori Temperature and e Convertitori signal transmitters

More information

SERVOMOTORI BRUSHLESS BRUSHLESS SERVOMOTORS

SERVOMOTORI BRUSHLESS BRUSHLESS SERVOMOTORS SERVOMOTORI BRUSHLESS BRUSHLESS SERVO P R O L I N E SERVOMOTORI BRUSHLESS BRUSHLESS SERVO 40-60 - 80 3 PROLINE S040 - PRESTAZIONI E SPECIFICHE PROLINE S040 - PERFORMANCE AND SPECIFICATIONS Tipo - Type

More information

Inductive Proximity Sensors

Inductive Proximity Sensors M12 Inductive Proximity Sensors Standard Length Mini's Extended Sensing 3 Wire DC 2 Wire DC 2 Wire AC (Wiring Schematic) 3 Wire DC PNP Normally Open (1) IMM32122C IMM35124C IMN32122C IMN35124C IMN32122M12

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

CONTATORE ENEL MONOFASE/TRIFASE CONTATORE TRIFASE DI ENERGIA ELETTRICA FIGURA 1: SCHEMA DI INSTALLAZIONE

CONTATORE ENEL MONOFASE/TRIFASE CONTATORE TRIFASE DI ENERGIA ELETTRICA FIGURA 1: SCHEMA DI INSTALLAZIONE 400 imp/kwh CONTATORE TRIFASE DI ENERGIA ELETTRICA Lo strumento in questione occupa 4 DIN (4X18 mm) e si alloggia facilmente in un normale quadretto, che abbia la guida DIN, lo strumento va installato

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Power Meter Series 700

Power Meter Series 700 PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required

More information

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800 Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

B12 INTERRUTTORI DI PROSSIMITA INDUTTIVI PUSH-PULL STANDARD SERIE SERIES INDUCTIVE PROXIMITY SWITCHES PUSH-PULL STANDARD B12

B12 INTERRUTTORI DI PROSSIMITA INDUTTIVI PUSH-PULL STANDARD SERIE SERIES INDUCTIVE PROXIMITY SWITCHES PUSH-PULL STANDARD B12 INTERRUTTORI DI PROSSIMITA INDUTTIVI PUSH-PULL STANDARD SERIE SERIES B12 INDUCTIVE PROXIMITY SWITCHES PUSH-PULL STANDARD INTERRUTTORI DI PROSSIMITA INDUTTIVI CON ELETTRONICA PUSH-PULL STANDARD INDUCTIVE

More information

DESCRIPTION DESCRIZIONE

DESCRIPTION DESCRIZIONE ssptl7r- 04/2014 Cassetta con finecorsa trasmettirore di posizione - Limit switch box position transmitter Disponibile - Available 94/9/EC (ATEX) PTL7 è una cassetta interamente realizzata in Alluminio

More information

C01 INTERRUTTORI DI PROSSIMITA INDUTTIVI AMPLIFICATI A DUE FILI IN CORRENTE ALTERNATA SERIE SERIES

C01 INTERRUTTORI DI PROSSIMITA INDUTTIVI AMPLIFICATI A DUE FILI IN CORRENTE ALTERNATA SERIE SERIES INTERRUTTORI DI PROSSIMITA INDUTTIVI AMPLIFICATI A DUE FILI IN CORRENTE ALTERNATA SERIE SERIES INDUCTIVE PROXIMITY SWITCHES AMPLIFIED TWO WIRES ALTERNATE CURRENT INTERRUTTORI DI PROSSIMITA INDUTTIVI AMPLIFICATI

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

PRODUCTS SERIES OL OP 50 OM 50 OL 60 PL 200 GL/TL 500 OP 100 OM 80 OL 80 PL 250 GL/TL 600 OL 150 PL 400

PRODUCTS SERIES OL OP 50 OM 50 OL 60 PL 200 GL/TL 500 OP 100 OM 80 OL 80 PL 250 GL/TL 600 OL 150 PL 400 CDS Elettronica - www.cdselettronica.it PRODUCTS SERIES OP SERIES OM SERIES OL SERIES PL SERIES GL/TL OP 50 OM 50 OL 60 PL 200 GL/TL 500 OP 100 OM 80 OL 80 PL 250 GL/TL 600 OL 100 PL 300 GL/TL 700 OL 130

More information

80 Series - Modular timers 16 A. Features 80.01 80.11

80 Series - Modular timers 16 A. Features 80.01 80.11 80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h

More information

Energy Management Power Analyzer Type WM14-96 Basic Version

Energy Management Power Analyzer Type WM14-96 Basic Version Energy Management Power Analyzer Type WM-96 Basic Version Optional dual pulse output Alarms (visual only) V, An Optional galvanically insulated measuring inputs Product Description 3-phase power analyzer

More information

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.

More information

Strumenti digitali - Digital instruments SOMMARIO - INDEX

Strumenti digitali - Digital instruments SOMMARIO - INDEX Strumenti digitali - Digital instruments SOMMRIO - INDEX Tipo Digit Lettura Pag. Type Reading Page Strumenti / Instruments 72x72 mm DF 34 3 999-3 DF 72 3 999-26 DF 73 3 x 3 999-27 DM 42 4 9999-6 Strumenti

More information

Energy Management Energy Meter Type EM23 DIN

Energy Management Energy Meter Type EM23 DIN Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

Rotatori Rotators Pinze per tronchi Log grapples

Rotatori Rotators Pinze per tronchi Log grapples Rotatori Rotators Pinze per tronchi Log grapples Prodotti - Products Rotatori / Rotators IVR 3 / IVR 3 FS IVR 4 / 4FS / 4 FG IVR 5 / IVR 5FS IVR 6 IVR 6F IGR 12. 2F IGR 16 - Per piccole gru forestali e

More information

Vasche. Bathtub. Sense 3

Vasche. Bathtub. Sense 3 60 Vasche athtub Sense 3 61 Sense 3 Vasca rettangolare / Rectangular bathtub cm 190x80 capacità / capacity 2 lt. cm 180x80 capacità / capacity 250 lt. cm 170x75 capacità / capacity 225 lt. cm 170x70 capacità

More information

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current. Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.

More information

Fixed - Over/Under voltage limits, (0.75...1.2) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Fixed - Over/Under voltage limits, (0.75...1.2) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay

More information

C Series. 16(5)A at 250V A.C 50Hz. 3A at 30V D.C. L/R=5ms 10 milioni di operazioni a 1 Hz / million operations at 1Hz 1250Vrms at 50Hz

C Series. 16(5)A at 250V A.C 50Hz. 3A at 30V D.C. L/R=5ms 10 milioni di operazioni a 1 Hz / million operations at 1Hz 1250Vrms at 50Hz C Series Il microinterruttore della serie C é un trasduttore elettromeccanico capace di commutare carichi fino a 20A, è dotato di lunga vita, bassa corsa differenziale, alta ripetibilità e buona resistenza

More information

ISOMAG Millennium UC 250 VERSIONE A PARETE UC 250 WALL VERSION UC 250 A QUADRO UC 250 PANEL MOUNTING VERSI ON

ISOMAG Millennium UC 250 VERSIONE A PARETE UC 250 WALL VERSION UC 250 A QUADRO UC 250 PANEL MOUNTING VERSI ON M I S U R A T O R I E L E T T R O M A G N E T I C I D I P O R T A T A S E R I E E L E C T R O M A G N E T I C F L O W M E T E R S E R I E S ISOMAG Millennium C O N V E R T E R M O D E L MUC 2 5 0 CONVERTITORE

More information

How To Prevent A Forklift From Tipping

How To Prevent A Forklift From Tipping The device "SSR-200" is a tool to implement security and agricultural machinery operators against the risk of tipping as a result of traveling on land too steep / inclined. Moreover, in case of actual

More information

MODULI INTERFACCIA A RELÈ ELETTROMECCANICI ELECTROMECHANICAL RELAY INTERFACE MODULES

MODULI INTERFACCIA A RELÈ ELETTROMECCANICI ELECTROMECHANICAL RELAY INTERFACE MODULES MODULI INTERFACCIA A RELÈ ELETTROMECCANICI ELECTROMECHANICAL RELAY INTERFACE MODULES SERIE RM A UN CONTATTO IN SCAMBIO pag. 3 ONE EXCHANGE CONTACT RM SERIES pag. 3 SERIE RM A UN CONTATTO SCAMBIO CON CONNETTORE

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

FX3 - FX4 SERIES. SENSORI FOTOELETTRICI A FIBRA OTTICA - SERIE FX FX series - photoelectric sensors FOR OPTICAL FIBRES FX3/0P-0A

FX3 - FX4 SERIES. SENSORI FOTOELETTRICI A FIBRA OTTICA - SERIE FX FX series - photoelectric sensors FOR OPTICAL FIBRES FX3/0P-0A SENSORI FOTOELETTRICI FIBR OTTIC - SERIE FX mplifiatore per fibra ottia da guida DIN serie FX3 e FX mplifier unit for optial fibres - DC FX3 and FX series Caratteristihe prinipali Main features > mplifiatore

More information

RGG WAVE. Alarm. Fault. Signalling Led di LEDs segnalazione. control RGM WAVE. Alarm. Fault. segnalazione. elettrovalvola

RGG WAVE. Alarm. Fault. Signalling Led di LEDs segnalazione. control RGM WAVE. Alarm. Fault. segnalazione. elettrovalvola GAS SAFETY GAS SAFETY Gas detectors LPG gas detectors - RGG Wave page 74 Methane gas detectors - RGM Wave page 74 Solenoid valves for gas Normally open solenoid valves page 78 Normally closed solenoid

More information

FOTOCELLULE CILINDRICHE M18 CON FIBRE OTTICHE TASTEGGIO DIRETTO E SBARRAMENTO

FOTOCELLULE CILINDRICHE M18 CON FIBRE OTTICHE TASTEGGIO DIRETTO E SBARRAMENTO FOTOCELLULE CILINDRICHE M18 CON FIBRE OTTICHE TASTEGGIO DIRETTO E SBARRAMENTO SERIE OCV81/F SERIES PHOTOELECTRIC CYLINDRICAL SENSORS WITH OPTIC FIBER DIFFUSE TYPE & BEAM TYPE FOTOCELLULE CILINDRICHE M18

More information

Current and voltage measuring relays

Current and voltage measuring relays Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application

More information

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation

More information

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications 077 Series Analogue Features Monitors and controls any variable which can be converted to an A.C. or D.C. signal. Rugged, shock and vibration resistant design Indicator, relays and power unit in one housing

More information

AE series. SENSORI INDUTTIVI - SERIE AE AE series - inductive sensors. Sensori di prossimità induttivi M8 serie AE. M8 proximity inductive sensors

AE series. SENSORI INDUTTIVI - SERIE AE AE series - inductive sensors. Sensori di prossimità induttivi M8 serie AE. M8 proximity inductive sensors Sensori di prossimità induttivi serie AE proximity inductive sensors rtteristiche principli Min fetures > Dimensioni estremmente ridotte > Extremely reduced mesure > orpo metllico > Metl housing > Indictore

More information

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders

More information

TERMINAL TACTIL A COLOR CON PLC INTEGRADO Pag 2. TERMINAL TACTIL MONOCROMO CON PLC INTEGRADO Pag 4. PANEL OPERADOR CON PLC INTEGRADO Pag 9

TERMINAL TACTIL A COLOR CON PLC INTEGRADO Pag 2. TERMINAL TACTIL MONOCROMO CON PLC INTEGRADO Pag 4. PANEL OPERADOR CON PLC INTEGRADO Pag 9 TERMINAL TACTIL A COLOR CON PLC INTEGRADO Pag 2 TERMINAL TACTIL MONOCROMO CON PLC INTEGRADO Pag 4 PANEL GRAFICO CON PLC INTEGRADO Pag 6 PANEL OPERADOR CON PLC INTEGRADO Pag 9 PLC FONDO PANEL CON DISPLAY

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

ISOpro T1+T2. Linea PROTECTION

ISOpro T1+T2. Linea PROTECTION ISOpro T1+T Scaricatori di corrente da fulmine e sovratensione ad alta prestazione da installare nella parte iniziale di distribuzioni a bassa tensione, per prevenire gli effetti derivanti da fenomeni

More information

9 MULTIMETRI DIGITALI MULTIFUNZIONE 9 DIGITAL MULTIFUNCTION MULTIMETERS

9 MULTIMETRI DIGITALI MULTIFUNZIONE 9 DIGITAL MULTIFUNCTION MULTIMETERS 9 MULTIMETRI DIGITALI MULTIFUNZIONE 9 DIGITAL MULTIFUNCTION MULTIMETERS 9 MULTIMETRI DIGITALI MULTIFUNZIONE 9 DIGITAL MULTIFUNCTION MULTIMETERS * Montaggio su guida DIN ( 3 o 6 moduli) * DIN rail mounting

More information

DUAL FUEL BURNERS GAS/HEAVY OIL

DUAL FUEL BURNERS GAS/HEAVY OIL M A D E I N I TA LY SERIE KN 750/M_1000/M EL DUAL FUEL BURNERS GAS/HEAVY OIL BRUCIATORI MISTI GAS/OLIO COMBUSTIBILE All purpose heating solutions Soluzioni integrate per il riscaldamento All purpose heating

More information

Technical note NT588 NT604 NT695 NT782

Technical note NT588 NT604 NT695 NT782 Multifunction 1.01 Model Nemo D4-b Nemo D4-L Nemo D4-L+ Codes MF6GT MF6FT0 MF6FTU MF6FT4 MF6HTU... MF6HT4... MF6HB... Ordering codes see page: 08 08 08 08 08 08 08 Connection on line single phase, 3-phase

More information

FACTORY AUTOMATION. Manual. Speed Monitor KHU8-DW-1.D

FACTORY AUTOMATION. Manual. Speed Monitor KHU8-DW-1.D FACTORY AUTOMATION Manual Speed Monitor KHU8-DW-.D With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

S-M series, connectors with modular inserts Serie S-M, connettori con inserti modulari 12.01

S-M series, connectors with modular inserts Serie S-M, connettori con inserti modulari 12.01 S- series, connectors with modular inserts Serie S-, connettori con inserti modulari.0 S- series, connectors with modular inserts Serie S-, connettori con inserti modulari Contents - Sommario Pages-Pagine

More information

020-inox 025-inox 040-inox 050-inox 070-inox 080-inox Elettropompe autoadescanti / Self-priming electric pumps

020-inox 025-inox 040-inox 050-inox 070-inox 080-inox Elettropompe autoadescanti / Self-priming electric pumps 080-inox 070-inox 050-inox 020-inox DESCRIZIONE E APPLICAZIONI Elettropope autoadescanti in acciaio inox AISI 316 ad anello liquido laterale largaente utilizzate nei settori nautico, agricolo ed industriale

More information

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment

More information

7 - Modules and sistems for PLC

7 - Modules and sistems for PLC 7 - Moduli e sistemi di cablaggio per PLC 7 - Modules and sistems for PLC Connessioni PLC per moduli a 32 ingressi PLC Connections to 32 input modules Connessioni PLC per moduli a 32 uscite PLC Connections

More information

Non solo un gruppo digitale: UNA VERA STAZIONE DI LAVORO! Not only a digital manifold: A TRUE WORK-STATION! NEW FOX EVO. Torr mtorr micron inhg

Non solo un gruppo digitale: UNA VERA STAZIONE DI LAVORO! Not only a digital manifold: A TRUE WORK-STATION! NEW FOX EVO. Torr mtorr micron inhg FOX EVO 62 Gruppo manometrico digitale a vie VANTAGGI EVO VACUOMETRO ELETTRONICO DI ALTA PRESSIONE INTEGRATO (0 900 Pa) BILANCIA, CAPACITÀ 0 100 KG, RISOLUZIONE 2G DATA LOGGER INTEGRATO MICRO SD CARD INCLUSA

More information

ERMA-Electronic GmbH - Max-Eyth-Str.8-78194 Immendingen - Tel: +49(0)7462/2000-0 - Fax: +49(0)7462/2000-29. Technische Änderungen vorbehalten

ERMA-Electronic GmbH - Max-Eyth-Str.8-78194 Immendingen - Tel: +49(0)7462/2000-0 - Fax: +49(0)7462/2000-29. Technische Änderungen vorbehalten Panel mounting instruments / DIN cabinets mounting different standard housing sizes different supply voltages all usual measured variables Measuring instruments programmable industrialfair execution customized

More information

Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com. Installation and operating manual

Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com. Installation and operating manual Uni-Valve A /S VENTILER & INSTRUMENTER Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com UNI-EL Electric actuator Installation and operating manual Remote position

More information

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43 Data sheet Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43 The three-phase monitoring relay CM-MPS.43 monitors the phase parameters phase sequence, phase failure, over- and undervoltage

More information

IP66. Apparecchio a incasso calpestabile per interni ed esterni. Walk over recessed fixture for indoor and outdoor applications

IP66. Apparecchio a incasso calpestabile per interni ed esterni. Walk over recessed fixture for indoor and outdoor applications A L P H A Apparecchio a incasso calpestabile per interni ed esterni Applicazione: pavimentazioni, facciate, alberi di piccola e media dimensione, controsoffitti, vetrine Ambientazione: porticati, passeggiate,

More information

Digital Clamp-on DMMs with uncompromising performance

Digital Clamp-on DMMs with uncompromising performance Digital Clamp-on DMMs with uncompromising performance With this new range of clamp-on meters, Metrix introduces practical and inexpensive instruments with uncompromising performance. Designed to satisfy

More information

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1 BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -

More information

www.motorpowerco.com ESA

www.motorpowerco.com ESA www.motorpowerco.com ESA ESA Una serie di servomotori a magneti permanenti sinonimo di durata, affidabilità e prestazioni dinamiche. Questa gamma completa, con coppie comprese tra 0,32 e 15 Nm, è l'ideale

More information

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection

More information

A project to optimise quality and energy efficiency must include metering

A project to optimise quality and energy efficiency must include metering EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,

More information

Multifunction devices

Multifunction devices devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2

More information

n N e E 0 m A R sr S l 10.2015 230/01

n N e E 0 m A R sr S l 10.2015 230/01 N 0 E A R n e msrls 10.15 230/01 Cablaggi LED LED wiring NEM s.r.l. ha nella propria gamma di prodotti due diversi cablaggi per LED. In its product range, NEM s.r.l. offers two different LED wirings. 051

More information

13/30 SERIES / SERIE 13/30 EIA 1 5/8 SERIES / SERIE EIA

13/30 SERIES / SERIE 13/30 EIA 1 5/8 SERIES / SERIE EIA 13/30 SERIES / SERIE 13/30 EIA 1 5/8 SERIES / SERIE EIA 1 5/8 EIA 1 5/8 CONNECTORS CONNETTORI EIA 1 5/8 2 Main Characteristics - Low reflection coefficient (up to 3 GHz) - Low IMD3 value (-162dBc) - Inner

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

80 Series - Modular timers 16 A. Features 80.01 80.11

80 Series - Modular timers 16 A. Features 80.01 80.11 80 Series - Modular timers 6 A 80. Multi-function and mono-function timer range - Multi-function & multi-voltage 80. - ON delay, multi-voltage 7.5 mm wide Six time scales from 0.s to 24h 35 mm rail (EN

More information

Speed Control Relays SX2

Speed Control Relays SX2 SX2 File 850 CONENS Description.....................................................Page General Information................................................ 2-3 SX2DV General Information...........................................

More information

Alimentatori LED LED drivers

Alimentatori LED LED drivers Alimentatori LED LED drivers ALimentatori LED LED drivers Alimentatori disponibili in diverse potenze e dimensioni con caratteristiche tecniche specifiche per settore di utilizzo Alimentatori per applicazioni

More information

Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL

Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL WARNING: READ AND UNDERSTAND THIS MANUAL BEFORE USING YOUR MULTIMETER. FAILURE TO UNDERSTAND AND COMPLY WITH WARNINGS AND OPERATING INSTRUCTIONS

More information

Digital Panel Meters Modular Indicator and Controller Type UDM35

Digital Panel Meters Modular Indicator and Controller Type UDM35 Digital Panel Meters Modular Indicator and Controller Type UDM35 Front protection degree: IP67, NEMA2, NEMA4x "Indoor use only" Linearization of Hz inputs up to 6 points Multiinput modular instrument 3

More information

QUADRO DI CONTROLLO / CONTROL BOARD

QUADRO DI CONTROLLO / CONTROL BOARD QUADRO DI CONTROLLO / CONTROL BOARD UNITÀ MOTOCONDENSANTE TRIFASE THREE-PHASE MOTOR-CONDENSING UNIT CEP 15 VXX CEP 22 VXX 2 Termostato Thermostat Pressostato Pressure switch Ventole condensatore Condenser

More information

THERMAL ENERGY METER MC 108/ET

THERMAL ENERGY METER MC 108/ET USCITE CONTATORE DI CALORE CONVERTITORE SENSORE ELETTROMAGN. EUROMAG CONTATORE DI ENERGIA TERMICA PORTATA: SENSORE ELETTROMAGN. uscite: TEMPERATURE: Pt 100 4-20 ma potenza termica 4-20 ma temperatura ta

More information

Dispositivi luminosi di emergenza Luminous warning devices

Dispositivi luminosi di emergenza Luminous warning devices italian quality Made in Italy Dispositivi luminosi di emergenza Luminous warning devices 325 Indice Index Dispositivi luminosi di emergenza Luminous warning devices 327-332 BMX AA BOX C2 BOX V4 BOX P6

More information

DISTRIBUTORI ROTANTI ELETTRICI E ELETTRO-IDRAULICI ELECTRO-HYDRAULIC ROTARY COUPLING

DISTRIBUTORI ROTANTI ELETTRICI E ELETTRO-IDRAULICI ELECTRO-HYDRAULIC ROTARY COUPLING t HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES HT / A / 50 / 006 / IE DISTRIBUTORI ROTANTI ELETTRICI E ELETTRO-IDRAULICI ELECTRO-HYDRAULIC ROTARY COUPLING INDICE - INDEX DISTRIBUTORI

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

INTERRUTTORI DI PROSSIMITA INDUTTIVI IN MINIATURA INDUCTIVE PROXIMITY SWITCHES MINIATURE SERIES

INTERRUTTORI DI PROSSIMITA INDUTTIVI IN MINIATURA INDUCTIVE PROXIMITY SWITCHES MINIATURE SERIES INTERRUTTORI DI PROSSIMITA INDUTTIVI IN MINIATURA SERIE SERIES MA INDUCTIVE PROXIMITY SWITCHES MINIATURE SERIES INTERRUTTORI DI PROSSIMITA INDUTTIVI IN MINIATURA INDUCTIVE PROXIMITY SWITCHES MINIATURE

More information

Operating and installation instructions. Professional plasma torch height control. Model: MyPlasm THC

Operating and installation instructions. Professional plasma torch height control. Model: MyPlasm THC Operating and installation instructions Professional plasma torch height control Model: MyPlasm THC Characteristics of the device: - A miniature casing for panel mounting - Full optical insulation of inputs

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

PFM 1 / A P - 1 H V5

PFM 1 / A P - 1 H V5 SENSORI INDUIVI PER APPIAIONI AIMENARI Sensori di prossimità induttivi M serie PFM per ppliczioni limentri M proximity inductive sensors for food nd beverge pplictions rtteristiche principli Min fetures

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR 2 MB 103 TRANSFORMER TEMPERATURE CONTROL UNIT WITH CONTROL SIGNAL Recent approval of new

More information