Determining the Variability of Continuous Mercury Monitors (CMMs) at Low Mercury Concentrations
|
|
- Shon Robertson
- 7 years ago
- Views:
Transcription
1 Determining the Variability of Continuous Mercury Monitors (CMMs) at Low Mercury Concentrations EUEC 2011 Phoenix, Arizona January 31 February 2, 2011 Dennis Laudal
2 Tekran Comments This presentation is the original except for the following. Slide 10 the probe labels were corrected Slide 15 The correct R and R 2 values are provided Other corrections for the EERC Research Report on the ICCI website can be found at
3 Program Partners Illinois Clean Coal Institute (ICCI) Dr. Francois Botha Electric Power Research Institute (EPRI) Mr. Charles Dene U.S. Department of Energy National Energy Technology Laboratory (DOE NETL) Mr. I. Andrew Aurelio Center for Air Toxic Metals (CATM ) Affiliates Program Mr. John Pavlish ThermoFisher Scientific Mr. Jeff Socha Tekran Instruments Mr. Karl Wilber OhioLumex Mr. Joseph Siperstein
4 Project Drivers U.S. Environmental Protection Agency (EPA) Maximum Achievable Control Technology (MACT) Regulations To meet regulations may require Hg control <1.0 µg/m 3. Compliance verification cannot be effected without accurate and traceable low-level Hg measurements. Hg Abatement System Control Accurate low-level Hg measurements are required to economically operate Hg reduction systems. Optimization of Coal Supply and Blending Strategies Will rely on accurate low-level Hg measurements (market acceptance of coal-fired plants may require measurement validation). Hg Abatement Research Low-level Hg measurements are required to properly assess new control technology performance.
5 Project Objectives The primary goal of the project is to determine the actual variability of CMMs at mercury concentrations <1.0 µg/nm 3. Determine the variability of the components of the mercuryspiking systems. Determine the zero-mercury concentration for the instruments. Based on true spiking values for Hg 0 and HgCl 2, determine the variability of the CMMs over a 4-hour time frame for three different mercury concentrations.
6 Project Objectives Compare the variability of carbon trap measurements using the OhioLumex and modified EPA Method Compare the variability results with and without acid gases (SO 2 and HCl) added to the flue gas. Determine the performance of the CMMs measuring low levels of mercury (<1.0 µg/nm 3 ) when firing coal.
7 Project Tasks Task 1 Design and build mercury-spiking systems and ensure all equipment is operating at the highest level. Task 2 Complete test plan firing natural gas (2-weeklong pilot-scale tests). Task 3 Complete test plan firing an Illinois (Knighthawk) bituminous coal.
8 Mercury Measurement Methods CMMs Tekran Model 3300 ThermoScientific Freedom System Sorbent trap method (EPA Method 30B), with traps to be supplied by OhioLumex Directly analyzed using the OhioLumex RA-915+ mercury analyzer with PYRO-915 attachment Analyzed by Frontier Geosciences using modified EPA Method 1631
9
10 Tekran ThermoScientific
11
12 Test Plan for Natural Gas Tests Test Condition Mercury Mercury Concentration, µg/nm 3 Blank 0 1 Hg Hg Hg HgCl HgCl HgCl Hg 0 and HgCl /0.25
13 Test Plan for Coal Test Pilot-Scale Test Firing a Knight Hawk Illinois Coal System Configuration: Boiler ESP Baghouse Wet FGD
14 Baseline Mercury Concentration Firing PTC on Natural Gas Date Time Sampled, min Hg on Trap, ng Sample 1 Sample 2 Measured Hg Conc., µg/nm 3 Hg on Trap, ng Measured Hg Conc., µg/nm 3 2/15/ /26/ /27/ /28/ /29/ /24/ /25/ /26/ /27/ Ambient Air Background Hg = 12 ng/m 3 (0.012 µg/nm 3 )
15 Thermo Results, µg/nm 3 on a wet basis Summary of Overall Results Sorbent Trap Data, µg/nm 3 on a wet basis Graph Error: Thermo R=0.863 and R 2 =0.745 Tekran R=0.995 and R 2 =0.990 R 2 = Natural Gas - No SO 2 and HCl Natural Gas - with SO 2 and HCl Illinois Coal Tekran Results, µg/nm 3 on a wet basis R 2 = Natural Gas - No SO 2 and HCl Natural Gas - with SO 2 and HCl Illinois Coal Sorbent Trap Data, µg/nm 3 on a wet basis
16 General Observations Overall, the testing went well. The baseline mercury levels when firing natural gas were very low (at or near ambient mercury levels). Both the Tekran and Thermo CMMs worked well on natural gas with and without the addition of the acid gases. The Tekran has a lower detection limit than the Thermo system, although both were challenged during the baseline conditions (no mercury added). The quadtrain sorbent trap results for all the tests provided a high level of precision.
17 General Observations The calibrators used for both instruments was consistent and within 10% of the stated value. The Tekran has a lower detection limit than the Thermo system, although both were challenged during the baseline conditions (no mercury added). Although there was some variability in the mercury emissions, the mercury concentrations were consistent over the time each quadtrain sorbent trap sample was taken. When firing coal, the Tekran appeared to match the sorbent results, but the Thermo system did not perform as well as expected.
18 Future Testing ThermoScientific believes they have determined the problem and are planning a repeat test under Subtask Testing to evaluate the effects of bromine addition when measuring low-level mercury concentrations. This project has the same partners except the Wyoming Clean Coal Program rather than ICCI.
19 Disclaimer This presentation was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government, nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof.
Assessing the Changes Required by the Industrial Boiler MACT Regulations
Technical Paper MS-17 Assessing the Changes Required by the Industrial Boiler MACT Regulations Authors: A.L. LeClair L.M. McDermitt Babcock & Wilcox Power Generation Group, Inc. Barberton, Ohio, U.S.A
More informationMercury Speciation in Flue Gas from Coal-fired Power Stations
Mercury Speciation in Flue Gas from Coal-fired Power Stations Matthew A Dexter, Warren T Corns and Peter B Stockwell P S Analytical Arthur House Crayfields Industrial Estate Main Road Orpington BR5 3HP
More informationMILLIKEN CLEAN COAL TECHNOLOGY DEMONSTRATION PROJECT UNIT 2 ELECTROSTATIC PRECIPITATOR PERFORMANCE TEST RESULTS BEFORE AND AFTER MODIFICATION
MILLIKEN CLEAN COAL TECHNOLOGY DEMONSTRATION PROJECT UNIT 2 ELECTROSTATIC PRECIPITATOR PERFORMANCE TEST RESULTS BEFORE AND AFTER MODIFICATION Prepared by: CONSOL Inc. Research & Development 4000 Brownsville
More informationContinuous Emissions Monitoring - Program 77
Program Description Program Overview Coal-fired power plants are in increased need of robust, accurate, and certifiable continuous emissions monitors (CEMs) for mercury, particulate matter (PM), acid gases,
More informationThe Regulatory Impact Analysis (RIA) for the Mercury Air Toxics Standard (MATS)
The Regulatory Impact Analysis (RIA) for the Mercury Air Toxics Standard (MATS) Kevin Culligan U.S. Environmental Protection Agency (EPA) Associate Division Director, Sector Policies and Programs Division
More informationFACT SHEET PROPOSED MERCURY AND AIR TOXICS STANDARDS
FACT SHEET PROPOSED MERCURY AND AIR TOXICS STANDARDS ACTION On March 16, 2011, the Environmental Protection Agency (EPA) issued a proposed rule that would reduce emissions of toxic air pollutants from
More informationThermo Scientific Arke SO 3 System. increased sensitivity. greater value
Thermo Scientific Arke SO 3 System increased sensitivity greater value Technology That Meets the Challenge The Thermo Scientific Arke SO 3 System, with built-in SO 3 generator, uses an advanced Quantum
More informationOTCQB: MEEC. Corporate Presentation
OTCQB: MEEC Corporate Presentation FORWARD LOOKING STATEMENTS This presentation contains forward-looking statements as defined in Section 21E of the Securities Exchange Act of 1934, as amended, that are
More informationRoadmap Performance Target Best technology Capability
Sulfur Dioxide Control Technologies In Electric Power Plants CCTR Basic Facts File #5 Brian H. Bowen, Marty W. Irwin The Energy Center at Discovery Park Purdue University CCTR, Potter Center, 500 Central
More informationFlue Gas Desulfurization CEMS Design Lessons Learned and Monitoring Technologies to Meet the New Mercury and Air Toxics (MATS) Rule
Flue Gas Desulfurization CEMS Design Lessons Learned and Monitoring Technologies to Meet the New Mercury and Air Toxics (MATS) Rule Cemtek Environmental, Interactive CEMS Workshop a technical solution
More informationIntegrated Tools for Multifamily Green Asset Management. Energy Upgrade CA Web Portal Funding Finder Compass Portfolio Tracker Webinar May 22, 2012
Integrated Tools for Multifamily Green Asset Management Energy Upgrade CA Web Portal Funding Finder Compass Portfolio Tracker Webinar May 22, 2012 Webinar Agenda 2 Introductions Energy Upgrade California
More informationHow China Can Leapfrog. Mercury Emission Reductions. Sid Nelson Jr.
How China Can Leapfrog Title of Slide the World in Mercury Emission Reductions Sid Nelson Jr. Impressive Development Throughout China But Ever-Increasing Pollution Mercury from Power Plants Chinese Coals
More informationCost and Performance Metrics Used to Assess Carbon Utilization and Storage Technologies
Cost and Performance Metrics Used to Assess Carbon Utilization and Storage Technologies February 11, 2014 DOE/NETL-341/093013 OFFICE OF FOSSIL ENERGY Disclaimer This report was prepared as an account of
More informationMercury emissions control in two hazardous waste incineration plants with dry and semi-dry gas cleaning
Mercury emissions control in two hazardous waste incineration plants with dry and semi-dry gas cleaning X. Chaucherie Prof. Dr. B. W. Vosteen P. Berg April 15th, 2015 VDI Wissensforum 15 th Conference
More informationSoftware Quality Assurance Plan for the Hydrologic Evaluation of Landfill Performance (HELP) Model. Author: Mark A. Phifer OCTOBER, 2006
DISCLAIMER This report was prepared for the United States Department of Energy under Contract No. DE-AC09-96SR18500 and is an account of work performed under that contract. Neither the United States Department
More informationBill Maxwell, U.S. Environmental Protection Agency, OAQPS (C439-01)
TO: Bill Maxwell, U.S. Environmental Protection Agency, OAQPS (C439-01) FROM: Jeffrey Cole, RTI International DATE: December 2003 SUBJECT: Methodology for Estimating Cost and Emissions Impact for Coal-
More informationWET BULB GLOBE TEMPERATURE MEASUREMENT AT THE Y-12 NATIONAL SECURITY COMPLEX
WET BULB GLOBE TEMPERATURE MEASUREMENT AT THE Y-12 NATIONAL SECURITY COMPLEX Thomas E. Bellinger, CCM Y-12 National Security Complex Oak Ridge, Tennessee 1. INTRODUCTION To better serve the needs of the
More informationNETL Life Cycle Inventory Data Process Documentation File
NETL Life Cycle Inventory Data Process Documentation File Process Name: Uranium Open Pit Mining and Milling, Operations Reference Flow: 1 kg of Uranium Yellowcake (U 3 O 8 ) Brief Description: This process
More informationMATHESON STACK EMISSION CALIBRATION PROGRAM. Experience the MATHESON Commitment to Supply Chain Excellence
MATHESON STACK EMISSION CALIBRATION PROGRAM MATHESON STACK EMISSION CALIBRATION PROGRAM MATHESON is a single source for industrial, medical, specialty, and electronics gases as well as gas handling equipment,
More informationConfiguring Apple Mail for Mac OS X (Mountain Lion)
Configuring Apple Mail for Mac OS X (Mountain Lion) This document assumes that you already have Apple Mail installed on your computer and you are ready to configure Apple Mail. Table of Contents Configuring
More informationNUTC R304. Use of Absorption Mechanisms to Decrease Heavy Metal Mobility
Use of Absorption Mechanisms to Decrease Heavy Metal Mobility by Jianmin Wang Honglan Shi Joe G. Burken NUTC R304 A National University Transportation Center at Missouri University of Science and Technology
More informationEarly Fuel Cell Market Deployments: ARRA and Combined (IAA, DLA, ARRA)
Technical Report NREL/TP-56-588 January 3 Early Fuel Cell Market Deployments: ARRA and Combined (IAA, DLA, ARRA) Quarter 3 Composite Data Products Jennifer Kurtz, Keith Wipke, Sam Sprik, Todd Ramsden,
More informationTesting of Kaonetics Devices at BNL
BNL-95365-2011-IR Testing of Kaonetics Devices at BNL A. Bolotnikov, G. Smith and R. James June 2011 Nonproliferation and National Security Department Brookhaven National Laboratory U.S. Department of
More informationScience Goals for the ARM Recovery Act Radars
DOE/SC-ARM-12-010 Science Goals for the ARM Recovery Act Radars JH Mather May 2012 DISCLAIMER This report was prepared as an account of work sponsored by the U.S. Government. Neither the United States
More informationWinMagic Encryption Software Installation and Configuration
WinMagic Encryption Software Installation and Configuration Don Mendonsa, Faranak Nekoogar, Harry Martz Lawrence Livermore National Laboratory Livermore, CA 94551 Work performed on the Science & Technology
More informationWhite Paper: EPRI s Preliminary Evaluation of the Available HAPs ICR Data Paul Chu, Naomi Goodman Amended January 7, 2011
White Paper: EPRI s Preliminary Evaluation of the Available HAPs ICR Data Paul Chu, Naomi Goodman Amended January 7, 2011 1. Background In December 2009, the U.S. Environmental Protection Agency (EPA)
More informationPotential of Energy Efficiency and Renewable Energy Savings To Impact Florida s Projected Energy Use in 2014
Potential of Energy Efficiency and Renewable Energy Savings To Impact Florida s Projected Energy Use in 2014 Author Fairey, Philip Publication Number FSEC-RR-58-06 Copyright Copyright Florida Solar Energy
More informationBuilding Analytics. Managed Services. Better Building Alliance Department of Energy April 17, 2015
Disclaimer This document was prepared as an account of work sponsored by the United States Government. While this document is believed to contain correct information, neither the United States Government
More informationPhoenix Process Engineering, Inc. Project Experience Helping Clients Achieve MACT Compliance
Phoenix Process Engineering, Inc. Project Experience Helping Clients Achieve MACT Compliance The Boiler MACT, 40 CFR 63, Subpart DDDDD, was vacated in 2007 by the U.S Court of Appeals and the 2004 rule
More informationMicrogrids. EEI TDM Meeting Charleston, South Carolina October 7, 2013. Neal Bartek Smart Grid Projects Manager
Microgrids EEI TDM Meeting Charleston, South Carolina October 7, 2013 Neal Bartek Smart Grid Projects Manager 2012 San Diego Gas & Electric Company. All trademarks belong to their respective owners. All
More informationSmall Modular Nuclear Reactors: Parametric Modeling of Integrated Reactor Vessel Manufacturing Within A Factory Environment Volume 1
Small Modular Nuclear Reactors: Parametric Modeling of Integrated Reactor Vessel Manufacturing Within A Factory Environment Volume 1 Xuan Chen, Arnold Kotlyarevsky, Andrew Kumiega, Jeff Terry, and Benxin
More informationLIMITATIONS ON HIGH DATA RATE OPTICAL FIBER TRAN-SMISSION SYSTEMS DUE TO TRANSMISSION IMPAIRMENT
PAIR GRANT D OE/ER/ 14916-3 LIMITATIONS ON HIGH DATA RATE OPTICAL FIBER TRAN-SMISSION SYSTEMS DUE TO TRANSMISSION IMPAIRMENT Final Report 9/15/98-9/14/01 Curtis R. Menyuk Department of Computer Science
More informationETV Joint Verification Statement
THE ENVIRONMENTAL TECHNOLOGY VERIFICATION PROGRAM U.S. Environmental Protection Agency ETV Joint Verification Statement TECHNOLOGY TYPE: Continuous Emission Monitor APPLICATION: TECHNOLOGY NAME: COMPANY:
More informationThis document was prepared in conjunction with work accomplished under Contract No. DE-AC09-96SR18500 with the U. S. Department of Energy.
This document was prepared in conjunction with work accomplished under Contract No. DE-AC09-96SR18500 with the U. S. Department of Energy. DISCLAIMER This report was prepared as an account of work sponsored
More informationConfiguring Apple Mail for Mac OS X (Snow Leopard)
Configuring Apple Mail for Mac OS X (Snow Leopard) This document assumes that you already have Apple Mail installed on your computer and you are ready to configure Apple Mail. Table of Contents Configuring
More informationLLNL-TR-419602. SAVANT Status Report. Arden Dougan. November 6, 2009
LLNL-TR-419602 SAVANT Status Report Arden Dougan November 6, 2009 Disclaimer This document was prepared as an account of work sponsored by an agency of the United States government. Neither the United
More informationTECHNICAL BRIEFING SHEET NRG Texas Power LLC Permit No.: HAP-14
TECHNICAL BRIEFING SHEET NRG Texas Power LLC Permit No.: HAP-14 PROJECT DESCRIPTION: NRG Texas Power LLC (NRG Texas) has requested a Hazardous Air Pollutant (HAP) Major Source [FCAA 112(g)] Permit HAP-14,
More informationAmorphous Transparent Conducting Oxides (TCOs) Deposited at T 100 C
Amorphous Transparent Conducting Oxides (TCOs) Deposited at T 100 C John Perkins, Maikel van Hest, Charles Teplin, Jeff Alleman, Matthew Dabney, Lynn Gedvilas, Brian Keyes, Bobby To, David Ginley National
More informationFlue Gas Mercury Removal Using Carbon- Polymer Composite Material
Flue Gas Mercury Removal Using Carbon- Polymer Composite Material X. Sean Lu, Zach Xu, Steve Stark, Richard Gebert, W.L. Gore &, Inc. Tom Machalek, Carl Richardson, Jennifer Paradis, URS Corporation Ramsay
More informationElectricity Sources. Coal Fleet
This paper is called Coal Facts because it provides factual information and data related to coal-based electricity. Most of the data are taken from independent third party sources, such as the Energy Information
More informationSLMA Meeting. Boiler MACT and Related Rules. Atlanta, GA March 2, 2011. Martin Rollins, P. E. H. M. Rollins Company, Inc. Gulfport, Mississippi
SLMA Meeting Atlanta, GA March 2, 2011 Boiler MACT and Related Rules Martin Rollins, P. E. H. M. Rollins Company, Inc. Gulfport, Mississippi Boiler MACT and Related Rules EPA Had Requested 15 Month Delay
More informationHybrid Power Generations Systems, LLC
Coal Integrated Gasification Fuel Cell System Study Pre-Baseline Topical Report April 2003 to July 2003 Gregory Wotzak, Chellappa Balan, Faress Rahman, Nguyen Minh August 2003 Performed under DOE/NETL
More informationUser Guide. The Business Energy Dashboard
User Guide The Business Energy Dashboard 1 More Ways to Understand and Control Your Energy Use At FPL, we re investing in smart grid technologies as part of our commitment to building a smarter, more reliable
More informationMallinckrodt Inc. Cell Process Dismantling Perimeter Air Monitoring Program. HoltraChem Manufacturing Facility Orrington, Maine
Mallinckrodt Inc. Cell Process Dismantling Perimeter Air Monitoring Program HoltraChem Manufacturing Facility Orrington, Maine Revised January 30, 2003 Revised March 7, 2003 Work Plan Contents Section
More informationElectric Utilities and Water: Emerging Issues and R&D Needs
Electric Utilities and Water: Emerging Issues and R&D Needs Thomas J. Feeley, III U.S. Department of Energy National Energy Technology Laboratory 626 Cochrans Mill Road Pittsburgh, PA 15236 Phone: 412-386-6134
More informationSecond Line of Defense Virtual Private Network Guidance for Deployed and New CAS Systems
PNNL-19266 Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830 Second Line of Defense Virtual Private Network Guidance for Deployed and New CAS Systems SV Singh AI Thronas January
More informationElastomer Compatibility Testing of Renewable Diesel Fuels
National Renewable Energy Laboratory Innovation for Our Energy Future A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Elastomer Compatibility Testing
More informationSO 3 -Monitoring in Flue Gas of a Power Plant Application & Results
of a Power Plant Application & Results : Introduction - SO 3 / H 2 SO4 - The SO 3 Challenge : Spectral evaluation - Components to be monitored - Calibration : Analyzer Setup : Field Test Results : Benefits
More informationINDUSTRIAL BOILER MACT FACTSHEET
INDUSTRIAL BOILER MACT FACTSHEET The National Emission Standards for Hazardous Air Pollutants (NESHAP) for Industrial/Commercial/Institutional Boilers and Process Heaters (40 CFR Part 63, Subpart DDDDD),
More informationSite Identification No.: 197809AAO Application No.: 15030051
Project Summary for a Construction Permit Application from Midwest Generation for a Natural Gas Conversion Project for the Joliet Electric Generating Station Joliet, Illinois Site Identification No.: 197809AAO
More informationEnhanced Capture of Mercury in Baghouse
Enhanced Capture of Mercury in by using Novel Filtration Media and Filter Design Vishal Bansal, Robert W. Taylor, Pete Maly, and Bryan Yetter Abstract Study was conducted at a 5-MW equivalent slipstream
More informationHow To Make A Carbon Capture Plant Workable
IEA MOST Workshop: Advances in deployment of fossil fuel technology Beijing June 25, 2014 US DOE National Carbon Capture Center Power Systems Development Facility (PSDF) started combustion testing June
More informationHyDIVE (Hydrogen Dynamic Infrastructure and Vehicle Evolution) model analysis. Cory Welch. Hydrogen Analysis Workshop, August 9-10 Washington, D.C.
HyDIVE (Hydrogen Dynamic Infrastructure and Vehicle Evolution) model analysis Cory Welch Hydrogen Analysis Workshop, August 9-10 Washington, D.C. Disclaimer and Government License This work has been authored
More informationUp to $750 (or 30% of the project cost, whichever is less), for
For a limited time, the City of Wheaton is offering qualified residents a unique opportunity to improve their home s energy efficiency. By identifying and implementing steps to make their home more energy
More informationDistribution of Terminal Lung and Liver Dose Rates in United States Transuranium and Uranium Registries Registrants
56 th Annual Meeting of the Health Physics Society June 27, 2011, Palm Beach, FL Slide 1 Distribution of Terminal Lung and Liver Dose Rates in United States Transuranium and Uranium Registries Registrants
More informationDrupal Automated Testing: Using Behat and Gherkin
PNNL-23798 Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830 Drupal Automated Testing: Using Behat and Gherkin Thomas Williams Thom.Williams@pnnl.gov Carolyn Wolkenhauer Carolyn.Wolkenhauer@pnnl.gov
More informationNGNP Risk Management Database: A Model for Managing Risk
INL/EXT-09-16778 Revision 1 NGNP Risk Management Database: A Model for Managing Risk John M. Beck November 2011 DISCLAIMER This information was prepared as an account of work sponsored by an agency of
More informationOPPORTUNITIES FOR HEAT RATE REDUCTIONS IN EXISTING COAL- FIRED POWER PLANTS: A STRATEGY TO REDUCE CARBON CAPTURE COSTS
CONFERENCE PROCEEDINGS OPPORTUNITIES FOR HEAT RATE REDUCTIONS IN EXISTING COAL- FIRED POWER PLANTS: A STRATEGY TO REDUCE CARBON CAPTURE COSTS by Edward K. Levy, Nenad Sarunac, and Carlos Romero Energy
More informationW. C. Reinig. Savannah River Laboratory E. I. du Pent de Nemours and Company Aiken, South Carolina 298o1
.*. *.-a /dp73j/3~ DP-MS-68-48 calforn1um-252: A NEW SOTOPC SOUR(!EFOR NEUTRON RADOGRAPHY by W. C. Reinig Savannah River Laboratory E.. du Pent de Nemours and Company Aiken, South Carolina 298o1. SRL7
More informationNREL Job Task Analysis: Crew Leader
NREL Job Task Analysis: Crew Leader Chuck Kurnik National Renewable Energy Laboratory Cynthia Woodley Professional Testing Inc. NREL is a national laboratory of the U.S. Department of Energy, Office of
More informationThe Value of RECs in Renewable Project Financing
The Value of RECs in Renewable Project Financing Karlynn Cory Strategic Energy Analysis Center, NREL Renewable Energy Marketing Conference San Francisco, California December 5, 2006 RECs as a Revenue Stream
More informationUser Guide. The Business Energy Dashboard
User Guide The Business Energy Dashboard 1 More Ways to Understand and Control Your Energy Use At FPL, we re investing in smart grid technologies as part of our commitment to building a smarter, more reliable
More informationCleaning of Free Machining Brass
UCRL-TR-217975 Cleaning of Free Machining Brass T. Shen January 5, 2006 Disclaimer This document was prepared as an account of work sponsored by an agency of the United States Government. Neither the United
More informationPublic Service Co. of New Mexico (PNM) - Smoothing and Peak Shifting. DOE Peer Review Steve Willard, P.E. September 26, 2012
Public Service Co. of New Mexico (PNM) - PV Plus Storage for Simultaneous Voltage Smoothing and Peak Shifting DOE Peer Review Steve Willard, P.E. September 26, 2012 Project Goals Develop an even more Beneficial
More informationMeasurement of BET Surface Area on Silica Nanosprings
PNNL-17648 Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830 Measurement of BET Surface Area on Silica Nanosprings AJ Karkamkar September 2008 DISCLAIMER This report was prepared
More informationENVIROENERGY SOLUTIONS. Presentation of APC and Wet Electrostatic Precipitation Technology
ENVIROENERGY SOLUTIONS Presentation of APC and Wet Electrostatic Precipitation Technology Agenda Introduce participants Review WESP technology Review the Applications of WESP Questions & answers People
More informationPanel Session #4 Smart Grid Workforce Training and Education: Identifying the Industry Perspective
Panel Session #4 Smart Grid Workforce Training and Education: Identifying the Industry Perspective J.W. (Jim) Wheeler A Workshop on Building Research Collaborations: Electricity Systems MRGN Building Room
More informationConfiguring Outlook 2010 for Windows
Configuring Outlook 2010 for Windows This document assumes that you already have Outlook 2010 installed on your computer and you are ready to configure Outlook. Table of Contents Configuring Outlook 2010
More informationSmart Meter Deployment and Customer Opt-Out. Paul Gastineau Senior Director of Rates & Regulatory Research
Smart Meter Deployment and Customer Opt-Out Paul Gastineau Senior Director of Rates & Regulatory Research September 2013 1 CenterPoint Energy s (CEHE) Advanced Metering Journey 2008 2009-2010 2012 Completed
More informationThis document has been provided by the International Center for Not-for-Profit Law (ICNL).
This document has been provided by the International Center for Not-for-Profit Law (ICNL). ICNL is the leading source for information on the legal environment for civil society and public participation.
More informationState of the Art (SOTA) Manual for Boilers and Process Heaters
State of the Art (SOTA) Manual for Boilers and Process Heaters Original Date: July 1997 Revision Date: February 22, 2004 State of New Jersey Department of Environmental Protection Air Quality Permitting
More informationThe Fate of Ammonia and Mercury in the Carbon Burn-Out (CBO ) Process
The Fate of Ammonia and Mercury in the Carbon Burn-Out (CBO ) Process Vincent M Giampa Progress Materials, Inc., One Progress Plaza, St. Petersburg, Florida 33701 KEYWORDS: mercury, ammonia, carbon burn-out,
More informationOutage Notification. "Acknowledgment: This material is based upon work supported by the Department of Energy under Award Number DE-OE0000193.
Outage Notification "Acknowledgment: This material is based upon work supported by the Department of Energy under Award Number DE-OE0000193." Disclaimer: "This report was prepared as an account of work
More informationConfiguring Outlook 2011 for Mac with Google Mail
Configuring Outlook 2011 for Mac with Google Mail This document assumes that you already have Outlook 2011 installed on your computer and you are ready to configure Outlook with Google Mail. Table of Contents
More informationThe Future of Coal-Based Power Generation With CCS UN CCS Summit James Katzer MIT Energy Initiative web.mit.edu/coal/
The Future of Coal-Based Power Generation With CCS UN CCS Summit James Katzer MIT Energy Initiative web.mit.edu/coal/ 1 Times Are Changing As Yogi Berra said: The Future Ain t What It Used to Be 2 Overview
More informationConfiguring Outlook 2013 for Windows
Configuring Outlook 2013 for Windows This document assumes that you already have Outlook 2013 installed on your computer and you are ready to configure Outlook. Table of Contents Configuring Outlook 2013
More informationThe Economic, Environmental, and Social Benefits of Geothermal Use in Arizona
The Economic, Environmental, and Social Benefits of Geothermal Use in Arizona Andrew Chiasson Geo Heat Center Oregon Institute of Technology March 2011 Geothermal waters in Arizona have been used by many
More informationPenetration Testing of Industrial Control Systems
SF-1075-SUR (8-2005) SANDIA REPORT SAND2005-2846P Unlimited Release Printed March, 2005 Penetration Testing of Industrial Control Systems David P. Duggan Prepared by Sandia National Laboratories Albuquerque,
More informationExposures to Coal Fly Ash During Maintenance of Air Cleaning Devices in Power Plants
Exposures to Coal Fly Ash During Maintenance of Air Cleaning Devices in Power Plants Harry J Beaulieu, PhD, CIH, CSP President & Senior Scientist Industrial Hygiene Resources Boise, ID Arlen W Siert, PhD,
More informationAppendix 5A: Natural Gas Use in Industrial Boilers
Appendix 5A: Natural Gas Use in Industrial Boilers Industrial boilers consumed 2.1 Tcf of natural gas in 2006, accounting for 36% of total natural gas in manufacturing. 1 In this appendix, we provide further
More informationExamination syllabuses for Manual Stack emissions monitoring. Environment Agency Version 9 January 2015
Examination syllabuses for Manual Stack emissions monitoring Environment Agency Version 9 January 2015 Record of amendments Version Date Section Amendment number 6 August 09 Level 1 Updated Level 1 syllabus
More informationThe Production Cluster Construction Checklist
ARGONNE NATIONAL LABORATORY 9700 South Cass Avenue Argonne, IL 60439 ANL/MCS-TM-267 The Production Cluster Construction Checklist by Rémy Evard, Peter Beckman, Sandra Bittner, Richard Bradshaw, Susan Coghlan,
More informationNew Tools Using the Hardware Pertbrmaiihe... Monitor to Help Users Tune Programs on the Cray X-MP*
ANL/CP--7 4428 _' DE92 001926 New Tools Using the Hardware Pertbrmaiihe... Monitor to Help Users Tune Programs on the Cray X-MP* D. E. Engert, L. Rudsinski J. Doak Argonne National Laboratory Cray Research
More informationActive Vibration Isolation of an Unbalanced Machine Spindle
UCRL-CONF-206108 Active Vibration Isolation of an Unbalanced Machine Spindle D. J. Hopkins, P. Geraghty August 18, 2004 American Society of Precision Engineering Annual Conference Orlando, FL, United States
More informationDOCUMENT CONTROL AND CONDUCT OF OPERATIONS. S. K. Collinsand F. L. Meltzer Idaho National EngineeringLaboratory EG&G Idaho, Inc. Idaho Falls, ld 83415
DOCUMENT CONTROL AND CONDUCT OF OPERATIONS S. K. Collinsand F. L. Meltzer Idaho National EngineeringLaboratory EG&G Idaho, Inc. Idaho Falls, ld 83415 Abstract Departmentof Energy (DOE) Order5480.19, Conductof
More informationSituated Usability Testing for Security Systems
PNNL-20201 Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830 Situated Usability Testing for Security Systems FL Greitzer February 2011 DISCLAIMER This report was prepared as an
More informationFood Service Technology Center
Food Service Technology Center Electric Conveyor Toaster APW Wyott ECO4000-350E Test Report FSTC Report # 501311118 Application of ASTM Standard Test Method F2380 April 2012 Prepared by: Denis Livchak
More informationHow Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems
How Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems Paul Mathew, Ph.D., Staff Scientist Steve Greenberg, P.E., Energy Management Engineer
More informationGuidance and Reporting Instructions on Temporary E-reporting for the MATS Rule
Guidance and Reporting Instructions on Temporary E-reporting for the MATS Rule As explained in the interim MATS e-reporting rule, which was signed by the Administrator on March 9, 2015, the EPA plans to
More informationEmissions from Waste-to-Energy: A Comparison with Coal-fired Power Plants
Proceedings of IMECE 03 2003 ASME International Mechanical Engineering Congress & Exposition Washington, D.C., November 16-21, 2003 IMECE2003-55295 Emissions from Waste-to-Energy: A Comparison with Coal-fired
More informationClimate-Weather Modeling Studies Using a Prototype Global Cloud-System Resolving Model
ANL/ALCF/ESP-13/1 Climate-Weather Modeling Studies Using a Prototype Global Cloud-System Resolving Model ALCF-2 Early Science Program Technical Report Argonne Leadership Computing Facility About Argonne
More informationOutlook on Integrated Gasification Combined Cycle (IGCC) Technology
The IGCC Process: From Coal To Clean Electric Power Outlook on Integrated Gasification Combined Cycle (IGCC) Technology Testimony of Edward Lowe Gas Turbine-Combined Cycle Product Line Manager General
More informationModeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues
LBNL-6129E ERNEST ORLANDO LAWRENCE BERKELEY NATIONAL LABORATORY Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues Liping Wang, Tianzhen Hong Environmental
More informationDistribution of Terminal Lung and Liver Dose Rates in United States Transuranium and Uranium Registries Registrants
56 th Annual Meeting of the Health Physics Society June 27, 2011, Palm Beach, FL Slide 1 Distribution of Terminal Lung and Liver Dose Rates in United States Transuranium and Uranium Registries Registrants
More informationAn Estimate of Energy Use in Laboratories, Cleanrooms, and Data Centers in New York
FINAL 10-15-08 Technical Note An Estimate of Energy Use in Laboratories, Cleanrooms, and Data Centers in New York Paul Mathew, Ph.D. Staff Scientist Lawrence Berkeley National Laboratory Prepared for:
More informationCOMPARISON OF INDIRECT COST MULTIPLIERS FOR VEHICLE MANUFACTURING
COMPARISON OF INDIRECT COST MULTIPLIERS FOR VEHICLE MANUFACTURING Technical Memorandum in support of Electric and Hybrid Electric Vehicle Cost Estimation Studies by Anant Vyas, Dan Santini, and Roy Cuenca
More informationConfiguring Outlook 2016 for Windows
Configuring Outlook 2016 for Windows This document assumes that you already have Outlook 2016 installed on your computer and you are ready to configure Outlook. Table of Contents Configuring Outlook 2016
More informationFEMP Designated Product Assessment for Commercial Gas Water Heaters
FEMP Designated Product Assessment for Commercial Gas Water Heaters Jim Lutz Energy Analysis Department Lawrence Berkeley National Laboratory Berkeley, CA 94720 April, 2010 This work was supported by the
More informationSULFURIC ACID MIST PERFORMANCE TEST PROTOCOL. Duke Energy Florida, Inc. Crystal River Power Plant Units 4&5 Crystal River, Citrus County, Florida
SULFURIC ACID MIST PERFORMANCE TEST PROTOCOL Duke Energy Florida, Inc. Crystal River Power Plant Units 4&5 Crystal River, Citrus County, Florida August 2013 CONTENTS SECTION 1.0 INTRODUCTION...3 SECTION
More informationFile System-Aware Job Scheduling with Moab