Argon Medical Devices
|
|
|
- Lambert Brown
- 9 years ago
- Views:
Transcription
1 Argon Product Catalogue 2013
2 Argon Medical Devices Company History Founded in 1972 in Garland, Texas, Argon Medical Devices is a global manufacturer and supplier of specialty medical products headquartered in Plano, Texas, with manufacturing in both Texas (Athens) and Singapore (Yishun). Argon offers a broad line of medical devices for Interventional Radiology, Vascular Surgery, Interventional Cardiology, and Critical Care procedures. Argon has successfully grown into a leading Global supplier of devices to the healthcare marketplace and Argon s brand is recognised for producing quality products at competitive prices. Our newest products include the Option TM Retrievable Inferior Vena Cava Filter, Cleaner TM Rotational Thrombectomy System, and UltraStream TM Chronic Dialysis Catheters. Following the acquisition of the BD (Becton Dickinson) Critical Care and Extended Dwell Catheter (EDC) business in 2010, Argon also offers a range of pressure transducers and Gabarith TM tested transducer sets, PICC and Midline catheters, introducer sheaths, endomyocardial biopsy forceps, and other vascular products. Argon s established sales and marketing infrastructure serves a broad and diversified global Customer base through both a direct sales force, and through long-standing relationships with OEMs, strategic partners, and leading medical device distributors. Argon History 1972 Argon founded in Garland, Texas by James Eddings to market a proprietary guidewire 1981 Argon relocates to current manufacturing location in Athens, Texas 1991 Introduced catheterisation lab introducers, Jawz TM biopsy forceps, 2003 Argon launched the 1Step TM Introducer 2003 Argon device business acquired by RoundTable Healthcare Partners (RTHP) 2010 RTHP increases the Argon portfolio of products through the acquisition of the Rex Medical Interventional Radiology and Dialysis products (Option TM IVC Filter, Cleaner TM Mechanical Thrombectomy Device and UltraStream TM Chronic Dialysis Catheter) RTHP further increases the Argon portfolio of products through the acquisition of the Becton Dickinson (BD) Critical Care and Extended Dwell Catheter (EDC) Businesses About Argon Critical Care and Extended Dwell Catheter products With a long history and experience in invasive blood pressure monitoring dating back to 1946 with the introduction of the first reusable transducer under the Statham name, followed by such names as Gould, Spectramed and Ohmeda, the current Argon Gabarith TM tested disposable transducer technology is recognised globally as a market leader for ease of priming, accuracy of pressure transmission, safe arterial blood sampling solutions and unique safety features, protecting Clinical Staff and Patients alike. Additionally, with single lumen central venous access devices such as Secalon TM T, and single/multi-lumen Careflow TM Central Venous Catheters, Arterial Catheters, Criticath TM Pulmonary Artery Catheters and accessories and First PICC TM & L-Cath TM long term catheter products, Argon also offers a significant portfolio of Critical Care and EDC solutions. About RoundTable Healthcare Partners RoundTable Healthcare Partners, Lake Forest, IL, is an operating-oriented private equity firm focused exclusively on the health-care industry. RoundTable partners with companies that can benefit from its extensive industry relationships and proven operating and transaction expertise. RoundTable has established a successful track record of working with owner/founders, family companies, management teams, entrepreneurs and corporate partners who share a vision and believe in the value creation potential of its partnership model. More information about RoundTable Healthcare Partners can be found at:
3 Contents Argon Interventional Cardiology and Radiology Products 4 Option TM 4 Cleaner TM 5 UltraStream TM 6 Jawz TM7 7 Axcess TM 8 1Stic TM 9 MicroStic TM 10 Arterial Access 11 Guidewires 13 Argon Fluid Management Systems 17 Manifolds and High Pressure Injection Lines 17 Control Syringes 19 Colour d Medication Syringes 20 Argon PICC and Midline Catheters 21 Extended Dwell Catheter Products 21 Introducers & Modified Seldinger Technique (MST) Introducer Sets 22 L-Cath TM Polyurethane PICC and Midline Catheters 23 First PICC TM Silicone PICC and Midline Catheters 24 Argon Central Venous Catheters 25 Floswitch TM 25 Secalon T TM Catheters 26 Careflow TM Single Lumen Catheters 27 Careflow TM Single Lumen Sets Catheters 28 Careflow TM Double/Triple Lumen Catheters 29 Careflow TM Quad/Quint Lumen Catheters 30 Hydrocath Assure TM Antimicrobial Coated Catheters 31 Argon Careflow TM Arterial Catheters 32 Argon Pulmonary Artery and Thermodilution Systems 33 Percutaneous Sheath Introducer Sets 33 Criticath TM Pulmonary Artery Catheters 34 Critikit TM Systems and Accessories 35 Argon Pressure Transducer Sets 36 DTX Plus TM Pressure Transducers 36 Gabarith TM Tested Transducer Sets 38 Safedraw TM Sets 39 Safedraw-P TM Sets 40 Paediatric and Neonatal Sets 42 Flexi Sets 43 RT2000 Sets 44 Cardiac Catheterisation Laboratory Transducer Sets 46 Pressure Lines and Accessories 48 Interface Cables 49 Appendix 54 Cannula/Catheter Conversion 54 Symbol Guidance 55 Index 56
4 Interventional Cardiology and Radiology Products Speciality Products Argon Option TM Inferior Vena Cava Filter Argon Option TM Inferior Vena Cava Filter Introducer Sheath Length (cm) Working Caval Diameter Content (Units) Product 6.5Fr OD (5Fr ID) 70cm Option TM Vena Cava Filter System Up to 32mm Each The Argon Option TM IVC Filter is used for the prevention of recurrent pulmonary embolism. Designed for both permanent and retrievable IVC Filter placement, the Argon Option TM IVC Filter offers the safety and stability required for permanent placement coupled with proven long term retrievability. Suitable for caval diameters up to 32mm, with no minimal caval restrictions, and deployed via a 6.5Fr OD (5Fr ID) x 70cm low-profile delivery sheath with infusion port, Option s precise placement is aided by the use of an innovative over-thewire curved pusher system. The spiral coiled sheath provides increased column strength and kink-resistance for ease of tracking, pushability, and delivery. Dilator, with 32mm spaced radiopaque markers for rapid vena cava measurement and helix formation end-holes compatible with power injectors up to 800 psi. Single, colour coded filter cartridge for Femoral or Jugular placement. Durable, one piece design of filter reduces the risk of fracture caused by bending stress 2. Resilient, electropolished, nitinol hypotube filter construction improves resistance to fracture caused by cyclic stress 1. The transitionless and sturdy design of the hook allows for ease of snaring and reduced risk of hook deformation during retrieval. The stable filter base conforms to the caval anatomy, reducing caval penetration 3 and aids in centering the filter whilst innovative retention anchors are designed to prevent caudal and cephalid migration. These curved, non-flexible anchors reduce caval wall penetration and provide the balance between stability and retrievability. Argon Option TM IVC Filter contents: Argon colour coded Option TM filter cartridge system for Femoral or Jugular placement, Argon 6.5Fr OD x 70cm low profile delivery sheath with side arm, Argon dilator with 32mm spaced R/O markers, Argon curved pusher and sheath cap. Class lll according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 3 years 1. Hodgson, Darel E., Ming H. Wu, and Robert J. Biermann. Shape Memory Alloys Online. Available SMA INC. 2. Medical Device Network March 2006 Nitinol: The Shape of Things to Come. 3. The Safety and Effectiveness of the Retrievable Option TM Vena Cava Filter: A United States Prospective Multicenter Clinical Study. Matthew S. Johnson, MD, James F. Benenati, MD, John A. Kaufman, MD, et al. J Vasc Interv Radiol 2010; 21:
5 Interventional Cardiology and Radiology Products Speciality Products Argon Cleaner * and Cleaner15 TM Rotational Thrombectomy Systems Argon Cleaner * and Cleaner15 TM Rotational Thrombectomy Systems Cleaner Sheath Length (cm) Cleaner Shaft OD Sinusoidal Wire Amplitude (mm) Content (Units) Product 65cm 6Fr Cleaner * Rotational Thrombectomy System 9mm Each cm 6Fr Cleaner * Rotational Thrombectomy System 9mm Each cm 7Fr Cleaner15 TM Rotational Thrombectomy System 15mm Each cm 7Fr Cleaner15 TM Rotational Thrombectomy System 15mm Each The Argon Cleaner * and Cleaner15 TM Rotational Thrombectomy Systems are indicated for mechanical declotting of native vessel dialysis fistulae and synthetic dialysis access grafts. Ergonomic, procedure-ready, one piece design device with no assembly required. Completely disposable no capital equipment required. Intuitive to operate, with quiet operation, facilitating patient comfort during procedure. Guidewire-like design with safety locking mechanism provides excellent steerability, whilst atraumatic tip provides patient safety in both AV fistulae and grafts. Innovative radiopaque S-wire design with choice of 9mm or 15mm sinusoidal wire amplitudes, designed to conform to varying lumen diameters whilst actively cleaning wall-adherent clot. Cleaner15 TM with larger wire diameter for increased pushability, increased torque and performance for efficient thrombus maceration and 15mm sinusoidal wire amplitude for enhanced removal of wall-adherent thrombus. Drive unit rotates the sinusoidal wire at up to 4,500 rpm creating a fluid vortex and gently macerating thrombus whilst reducing the risk of endothelial damage¹. The Cleaner * /Cleaner15 TM single sinusoidal wire is capable of cleaning around the opposing sheath, thereby reducing procedure time and sheath manipulation. 3-way sideport and distal sidehole on catheter (135 cm) allows for infusion of fluids and contrast media. Argon Cleaner * Rotational Thrombectomy System contents: One-piece, 6Fr Cleaner * Thrombectomy System with Sinusoidal wire and 6Fr OD sheath. For use with 6Fr sheath systems. Argon Cleaner15 TM Rotational Thrombectomy System contents: One-piece, 7Fr Cleaner15 TM Thrombectomy System with Sinusoidal wire and 7Fr OD sheath. For use with 7Fr sheath systems. Cleaner15 TM is contraindicated for vessels less than 6mm in diameter. Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 3 years 1. F. Vega, Safety Comparison of Cleaner * Rotational Thrombectomy System Versus Arrow PTD in Native Vessel * CLEANER and CLEANER15 are trademarks of Rex Medical.
6 Interventional Cardiology and Radiology Products Speciality Products Argon UltraStream TM Chronic Dialysis Catheters Argon UltraStream TM Chronic Dialysis Catheters UltraStream Catheter Length (cm) UltraStream OD (Fr) Content (Units) Product ARGON ULTRASTREAM TM CATHETER STANDARD SHEATH KIT 24cm 15.5Fr UltraStream TM Standard Kit cm 15.5Fr UltraStream TM Standard Kit cm 15.5Fr UltraStream TM Standard Kit cm 15.5Fr UltraStream TM Standard Kit cm 15.5Fr UltraStream TM Standard Kit ARGON ULTRASTREAM TM CATHETER PEEL-AWAY KIT 24cm 15.5Fr UltraStream TM Peel-Away Sheath Kit cm 15.5Fr UltraStream TM Peel-Away Sheath Kit cm 15.5Fr UltraStream TM Peel-Away Sheath Kit cm 15.5Fr UltraStream TM Peel-Away Sheath Kit cm 15.5Fr UltraStream TM Peel-Away Sheath Kit ARGON ULTRASTREAM TM CATHETER EXCHANGE KIT 24cm 15.5Fr UltraStream TM Exchange Kit 1 box of cm 15.5Fr UltraStream TM Exchange Kit 1 box of cm 15.5Fr UltraStream TM Exchange Kit 1 box of cm 15.5Fr UltraStream TM Exchange Kit 1 box of cm 15.5Fr UltraStream TM Exchange Kit 1 box of Argon UltraStream TM Chronic Dialysis Catheters are indicated for Haemodialysis and Apheresis. Argon UltraStream TM patented, dual independent arterial lumen design provide high flow rates of 500ml/min and allow for continued functional dialysis should infusion be restricted to one arterial lumen. Dual arterial lumens also reduce the risk of catheter side walling. The unique, transitionless, modified-tip design facilitates atraumatic over-the-wire insertion for first-time or Exchange insertions, without requirement for a peel-away sheath. Shortened length between distal lumens allows for more accurate tip placement whilst achieving zero recirculation rates during normal flow 1. Kink resistant Carbothane catheter material provides strength for catheter longevity and softness for patient comfort. The Carbothane thermo-sensitive biocompatible material is radiopaque for increased visibility whilst being resistant to iodine and alcohol degradation. Durable luer catheter connectors with easy-to-read printed priming volumes are ergonomically designed to withstand multiple connections and compatible with a broad spectrum of cleansing agents, thereby reducing the risk of cracking. 1 Data on file Argon UltraStream TM Chronic Dialysis Catheter Standard Kit contents: Argon UltraStream TM 15.5Fr Catheter, Flexible Stiffener, 16Fr Vessel Dilator, #11 Safety Scalpel, 18G x 2.75 Introducer Needle, Tunneling Device, 2 x Needleless Injection Site Caps, 2 x Adhesive Bandage, Safety Foam. (Recommended guidewire size: or x 120cm minimum length.) Argon UltraStream TM Chronic Dialysis Catheter Peel-Away Kit contents: Argon UltraStream TM 15.5Fr Catheter, 16Fr Peel-Away Sheath, Flexible Stiffener, 16Fr Vessel Dilator, x 80cm Guidewire, #11 Safety Scalpel, 18G x 2.75 Introducer Needle,Tunneling Device, 2 x Needleless Injection Site Caps, 2 x Adhesive Bandage, Safety Foam. Argon UltraStream TM Chronic Dialysis Catheter Exchange Kit contents: Argon UltraStream TM 15.5Fr Catheter, Flexible Stiffener, 2 x Needleless Injection Site Caps. & Class lll according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 2 years Carbothane is a registered trademark of the Lubrizol Corporation
7 Interventional Cardiology and Radiology Products Vascular Access Products Argon Jawz TM Endomyocardial Biopsy Forceps Argon Jawz TM Endomyocardial Biopsy Forceps Jaw OD (mm) Jaw OD (Fr) Jaw Volume (mm 3 ) Forcep Length (cm) Recommended Sheath Size (Fr) FEP Coating Tip Configuration Shaft Type Contents (Units) Product Fr Fr No Straight Formable Each Fr Fr Yes Pre-Curve Formable Each Fr Fr Yes Maxi-Curve Formable Each Fr Fr No Straight Formable Each Fr Fr Yes Pre-Curve Formable Each Fr Fr Yes Maxi-Curve Formable Each Fr Fr No Straight Formable Each Fr Fr Yes Straight Formable Each Fr Fr Yes Maxi-Curve Formable Each Fr Fr No Straight Formable Each Fr Fr No Straight Non-Formable Each Fr Fr Yes Straight Formable Each Fr Fr No Straight Formable Each Fr Fr No Straight Non-Formable Each Fr Fr No Straight Formable Each Fr Fr No Straight Formable Each Developed by transplant cardiologists for use by transplant cardiologists, Argon Jawz TM Endomyocardial Biopsy Forceps for the collection of biopsy tissue samples of the myocardium. The unique cutting edge design of Jawz TM Forceps facilitates superior surface alignment to provide a clean cut and improved quality of biopsy sample. The cutting jaws are precision machined from a proprietary alloy to remain sharp throughout the biopsy procedure. The precision-molded three-ringed handle provides a solid instrument feel and adapts to maintain the users desired thumb position. With formable and non-formable configurations to best suit your desired technique, Jawz TM Forceps stainless steel shafts are available with or without FEP Coating to support smooth shaft passage. Jawz TM Forceps shaft option of Straight, Pre-Curved and Maxi-Curved configurations to provide the best patient access. Argon Jawz TM Endomyocardial Biopsy Forcep Kit contents: Argon Jawz TM Endomyocardial Biopsy Forcep and Instructions for Use. Class lli according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 5 years (maximum)
8 Interventional Cardiology and Radiology Products Vascular Access Products Argon AXcess TM Introducer System for Cardiology and Radiology Applications Argon AXcess TM Introducer Sheath System Introducer Length (cm) Introducer Size (Fr) Guidewire Content (Units) Product 5.75cm 4Fr AXcess TM Introducer Sheath 0.021'' x 400mm Straight cm 5Fr AXcess TM Introducer Sheath 0.025'' x 400mm Straight cm 6Fr AXcess TM Introducer Sheath 0.032'' x 400mm Straight cm 7Fr AXcess TM Introducer Sheath 0.032'' x 400mm Straight cm 4Fr AXcess TM Introducer Sheath 0.035'' x 450mm 'J'/Straight cm 5Fr AXcess TM Introducer Sheath 0.038'' x 450mm 'J'/Straight cm 6Fr AXcess TM Introducer Sheath 0.038'' x 450mm 'J'/Straight cm 7Fr AXcess TM Introducer Sheath 0.038'' x 450mm 'J'/Straight cm 8Fr AXcess TM Introducer Sheath 0.038'' x 450mm 'J'/Straight cm 9Fr AXcess TM Introducer Sheath 0.038'' x 450mm 'J'/Straight cm 5Fr AXcess TM Introducer Sheath without Guidewire Accepts 0.035'' '' Wire cm 6Fr AXcess TM Introducer Sheath without Guidewire Accepts 0.035'' '' Wire cm 7Fr AXcess TM Introducer Sheath without Guidewire Accepts 0.035'' '' Wire cm 8Fr AXcess TM Introducer Sheath without Guidewire Accepts 0.035'' '' Wire cm 5Fr AXcess TM Introducer Sheath without Guidewire Accepts 0.035'' '' Wire cm 6Fr AXcess TM Introducer Sheath without Guidewire Accepts 0.035'' '' Wire cm 7Fr AXcess TM Introducer Sheath without Guidewire Accepts 0.035'' '' Wire Argon AXcess TM Catheter Lab Introducers with integrated sidearm are designed for arterial applications and left heart procedures. Radiopaque Pebax (Polyether Block Amide) sheath material with clear PVC sideport tubing, the thermally tapered sheath design of the Argon AXcess TM introducer provides smooth insertion and minimises catheter peelback. The AXcess TM introducer polyurethane obturator minimises damage to vessel intimal lining whilst the Flex Collar, with Suture Tab, reduces kinking risk and provides a convenient suture site. The siliconised valve and dilator facilitates ease of insertion and low insertion torque whilst the positive twist-lock dilator assembly prevents dilator push-back during insertion. The 3-Part hemostasis Valve of the Argon AXcess TM introducer prevents bleedback by effectively sealing around the inserted wire and catheter. Argon AXcess TM Introducer Sheath Kit contents: Argon AXcess TM Introducer Sheath and matched dilator. Guidewire configuration as shown in table. Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 5 years
9 Interventional Cardiology and Radiology Products Vascular Access Products Argon 1Stic TM Micro-Introducer Systems for Cardiology and Radiology Applications Argon 1Stic TM Micro-Introducer Sheath System Introducer Length (cm) Introducer Size (Fr) Needle Gauge/Length Guidewire (Core/Tip) Content (Units) Product 5.75cm 6Fr 1Stic TM Introducer Sheath 21G x 5.1cm 0.018'' x 45cm (Stainless Steel) cm 6Fr 1Stic TM Introducer Sheath 21G x 7cm 0.018'' x 45cm (Stainless Steel) cm 7Fr 1Stic TM Introducer Sheath 21G x 5.1cm 0.018'' x 45cm (Stainless Steel) cm 8Fr 1Stic TM Introducer Sheath 21G x 5.1cm 0.018'' x 45cm (Stainless Steel) cm 4Fr 1Stic TM Introducer Sheath 21G x 7cm 0.018'' x 45cm (Stainless Steel) cm 5Fr 1Stic TM Introducer Sheath 21G x 7cm 0.018'' x 45cm (Stainless Steel) cm 6Fr 1Stic TM Introducer Sheath 21G x 7cm 0.018'' x 45cm (Stainless Steel) cm 7Fr 1Stic TM Introducer Sheath 21G x 7cm 0.018'' x 45cm (Stainless Steel) cm 8Fr 1Stic TM Introducer Sheath 21G x 7cm 0.018'' x 45cm (Stainless Steel) cm 5Fr 1Stic TM Introducer Sheath 21G x 2.5cm 0.018'' x 45cm (Nitinol/Platinum) cm 6Fr 1Stic TM Introducer Sheath 21G x 5.1cm 0.018'' x 45cm (Nitinol/Platinum) cm 7Fr 1Stic TM Introducer Sheath 21G x 2.5cm 0.018'' x 45cm (Nitinol/Platinum) cm 4Fr 1Stic TM Introducer Sheath 21G x 7cm 0.018'' x 45cm (Nitinol/Platinum) cm 5Fr 1Stic TM Introducer Sheath 21G x 7cm 0.018'' x 45cm (Nitinol/Platinum) cm 6Fr 1Stic TM Introducer Sheath 21G x 7cm 0.018'' x 45cm (Nitinol/Platinum) cm 7Fr 1Stic TM Introducer Sheath 21G x 7cm Echogenic 0.018'' x 45cm (Nitinol/Platinum) cm 4Fr 1Stic TM Introducer Sheath 21G x 7cm Echogenic 0.018'' x 45cm (Nitinol/Platinum) cm 5Fr 1Stic TM Introducer Sheath 21G x 7cm Echogenic 0.018'' x 45cm (Nitinol/Platinum) cm 6Fr 1Stic TM Introducer Sheath 21G x 7cm Echogenic 0.018'' x 45cm (Nitinol/Platinum) Argon1Stic TM Micro-Introducers with integrated sidearm are designed to support smaller puncture site access for both arterial and venous procedures allowing the physician to insert an introducer utilising micro-puncture technology. Shorter sheath (5.75cm) versions designed for venous procedures in the neck or arm, the smooth transition between introducer sheath and dilator provides atraumatic, low-profile insertion, minimising the risk of vessel trauma and catheter peelback. The 1Stic TM micro tapered dilator transitions from 0.5Fr (for micro-access guidewire) to maximum French size whilst the Flex Collar, with Suture Tab, reduces kinking risk and provides a convenient suture site. The siliconised valve and dilator facilitates ease of insertion and low insertion torque whilst the positive twist-lock dilator assembly prevents dilator push-back during insertion. The 3-Part hemostasis Valve of the Argon 1Stic TM catheter prevents bleed-back by effectively sealing around the inserted wire and catheter. Radiopaque Pebax (Polyether Block Amide) sheath material with clear PVC sideport tubing, these introducer sets are available with a choice of Stainless Steel or Nitinol/Platinum guidewires, along with Echogenic introducer needle option, for increased visibility under Fluoroscopy and Ultrasound, whilst the 4Fr-8Fr introducer sizes allow for multiple device exchanges during procedure. Argon 1Stic TM Micro-Introducer Sheath Kit contents: Argon 1Stic TM Micro-Introducer Sheath, micro-tipped dilator, guidewire and introducer needle. Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 5 years
10 Interventional Cardiology and Radiology Products Vascular Access Products Argon MicroStic TM Introducer Systems for Cardiology and Radiology Applications Argon MicroStic TM Micro-Introducer Sheath System Introducer Length (cm) Introducer Size (Fr) Needle Gauge/Length Guidewire (Core/Tip) Content (Units) Product 10cm 4Fr MicroStic TM Introducer Sheath 21G x 7cm 0.018'' x 45cm (Stainless Steel) cm 5Fr MicroStic TM Introducer Sheath 21G x 7cm 0.018'' x 45cm (Stainless Steel) cm 4Fr MicroStic TM Introducer Sheath 21G x 7cm Echogenic 0.018'' x 45cm (Stainless Steel) cm 5Fr MicroStic TM Introducer Sheath 21G x 7cm Echogenic 0.018'' x 45cm (Stainless Steel) cm 4Fr MicroStic TM Introducer Sheath 21G x 7cm 0.018'' x 45cm (Nitinol/Platinum) cm 5Fr MicroStic TM Introducer Sheath 21G x 7cm 0.018'' x 45cm (Nitinol/Platinum) cm 4Fr MicroStic TM Introducer Sheath 21G x 7cm Echogenic 0.018'' x 45cm (Nitinol/Platinum) cm 5Fr MicroStic TM Introducer Sheath 21G x 7cm Echogenic 0.018'' x 45cm (Nitinol/Platinum) Argon MicroStic TM Micro Introducer, double dilator systems are designed to support smaller puncture site access for arterial applications and left heart procedures. Argon MicroStic TM Micro-Introducer systems eliminate the need to dilate up using multiple dilators and result in a tight seal around catheter by the vessel. A seamless transition between introducer sheath and dilator enablies a smooth, lowprofile insertion, thereby minimising the risk of vessel trauma and catheter peelback. Introducer sets are available with a choice of Stainless Steel, Nitinol/Platinum or Nitinol/Stainless guidewires, along with Echogenic introducer needle option, for increased visibility under Fluoroscopy and Ultrasound. The positive twist-lock dilator assembly prevents dilator push-back during insertion. 4Fr introducer: inner and outer dilators made from radiopaque Pebax (Polyether Block Amide) sheath material. 5Fr introducer: inner dilator made from radiopaque Pebax (Polyether Block Amide) and outer dilator made from HDPE (High Density Polyethylene) sheath materials. Argon MicroStic TM Micro-Introducer Sheath Kit contents: Argon MicroStic TM Introducer Sheath and matched dilator, 21G Introducer Needle and x 45cm Guidewire (as shown). Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 5 years
11 Interventional Cardiology and Radiology Products Vascular Access Products Argon Range of Arterial Access Needles Argon Range of Arterial Access Needles to provide vascular access for the percutaneous introduction of a guidewire Full Needle range available offering one-piece, two-piece & three-piece units to meet Customer Needs. Single wall thin-walled flashback needles, available as one-piece needle with removable hub (AMC/3), with finger grip hub (AMC/4), or with winged hub (AMC/4 with wings) (AMC = Argon Medical Corporation). Ultra-thin wall style needles, including: Percutaneous Entry two-piece needle with tapered outer cannula and bevelled solid stylet. AMC/4 one-piece needle with finger grip hub AMC/4 with wings one-piece needle with a winged hub Increased needle strength due to cannula being flared into needle hub. Argon Arterial Access Needles are siliconised for easier introduction into vasculature. Tapered, insert-moulded, crack- and chemical-resistant needle hubs facilitating guidewire introduction. Clear hubs facilitating rapid flashback visualisation. Double wall style needles, including: Percutaneous Entry two-piece needle with tapered outer cannula and bevelled solid stylet. Vented Percutaneous Entry - two-piece needle with tapered outer cannula and bevelled hollow stylet. Cournand three-piece needle with angled outer cannula, hollow and bevelled inner stylet protruding out of hub and a blunt obturator. Modified Cournand two-piece needle with angled outer cannula and hollow and bevelled inner stylet. Match-tapered ID & OD cannula tips ( Swaging ) decreases coring incidence and facilitates penetration. 100% inspection of inner & outer needle fit, eliminating spaces resulting in smoother needle insertion. Insert-moulded chemically resistant polypropylene hub with enhanced feel. Non-radiopaque hub and gripping shield eliminates x-ray shadow. See product table on next page. Argon Range of Arterial Access Needles Set Contents: Single packed Arterial Needle and protective sheath. Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 5 years
12 Interventional Cardiology and Radiology Products Vascular Access Products Argon Range of Arterial Access Needles Argon Arterial Needles Gauge Length (cm) For Guidewire Sizes Special Features Box Contents (Units) Product AMC/3 - ARTERIAL NEEDLE WITH REMOVABLE NEEDLE ADAPTER 18G 7cm G 3.8cm '' G 2.5cm '' AMC/4 - CLEAR FLASHBACK NEEDLE 18G 3.8cm G 7cm G 3.8cm G 2.5cm G 5.1cm G 7cm Extra Thin Wall AMC/4 - WINGED ARTERIAL NEEDLE 18G 7cm PERCUTANEOUS ENTRY NEEDLE 18G 7.3cm Two Part: Thin Wall Tapered Cannula and Inner Arterial Beveled Stylet G 7.3cm Two Part: Thin Wall Tapered Cannula and Vented Arterial Beveled Stylet Needle COURNAND STYLE NEEDLE 18G 5.4cm MODIFIED COURNAND STYLE NEEDLE Three Part: Outer Thin Wall Tapered Cannula, Inner Arterial Beveled and Round Ended Obturator G 5.4cm Two Part: Outer Thin Wall Tapered Cannula and Inner Arterial Beveled Needle
13 Interventional Cardiology and Radiology Products Vascular Access Products Argon Range of Standard and Speciality Guidewires Argon Range of Standard and Speciality Guidewires for use in the Critical Care, Cardiac Catheterisation Laboratory and Radiology Special Procedures environment Full range of guidewires offering Fixed Core/Straight, Fixed Core/ J, double ended and Fixed/Moveable Core Speciality wires to meet most customer needs. Choice of Stainless Steel (SS) and NiTiNol guidewires, with PTFE or Heparin/PTFE coating; lengths from 40cm to 260cm and diameters from to PTFE coating provides ultra-smooth surface to prevent catheter drag. Argon coil welding process ensures uniform diameter from tip to end. Enhanced flexible tip facilitates easy tip manipulation. Fixed and Moveable core options allowing for additional manipulation opportunity at the flexible wire tip. Five styles of guidewire available, offering the Customer superior choice based on personal technique: Standard: with traditional feel and performance Flexible: with softer tip for increased manoeuvrability Classic: with stiffer body for increased push ability. Zebra Tip (Z-Tip): with stiffer body for increased push ability. XTB: with stiffer body and a short taper for increased push ability Tip Styles: Straight J Tip - determined by the mm radius of the J. Double-Ended - normally Straight & 3mm J Newton - can be Long Taper (LT) 10cm, Long Long Taper (LLT) 15cm or Long Long Long Taper (LLLT) 20cm. Bentson - has no taper core for last 15cm Mandrel type - provides the maximum amount of body stiffness per the cross sectional area. See product table on next page. Argon Range of Standard and Speciality Guidewires Set Contents: Single packed coiled guidewire and protective sheath with straightener. Class IIa and lll according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 5 years
14 Interventional Cardiology and Radiology Products Vascular Access Products Argon Range of Standard and Speciality Guidewires Argon Guidewires - Fixed Core Straight Diameter (inch) Length (cm) Core Taper (cm) Tip Curve Radius Box Contents (Units) Product STAINLESS STEEL cm Stainless Steel 9.0 Straight cm Stainless Steel 9.0 Straight cm Stainless Steel 9.0 Straight cm Stainless Steel 9.0 Straight cm Stainless Steel 9.0 Straight cm Stainless Steel 9.0 Straight cm Stainless Steel 9.0 Straight cm Stainless Steel 9.0 Straight cm Stainless Steel 9.0 Straight cm Stainless Steel 8.5 Straight PTFE COATED STAINLESS STEEL cm PTFE Coated Stainless Steel 9.0 Straight cm PTFE Coated Stainless Steel (Heavy Duty) 3.5 Straight cm PTFE Coated Stainless Steel 8.5 Straight EXCHANGE WIRES - PTFE COATED cm Exchange Wires - PTFE Coated 9.0 Straight cm Exchange Wires - PTFE Coated 8.5 Straight cm Exchange Wires - PTFE Coated 8.5/3 Straight MANDREL WIRES FOR MICRO-PUNCTURE TECHNIQUE cm Stainless Steel 9.5 Straight cm NiTiNol (4.8cm Platinum Coil Tip) N/A Straight MULLINS TIP DEFLECTOR WIRES - STAINLESS STEEL cm Stainless Steel 1.5/2 Straight cm Stainless Steel 1.5 Straight
15 Interventional Cardiology and Radiology Products Vascular Access Products Argon Range of Standard and Speciality Guidewires Argon Guidewires - Fixed Core J Tip Diameter (inch) Length (cm) Core Taper (cm) Tip Curve Radius Box Contents (Units) Product PTFE COATED - STAINLESS STEEL cm mm cm mm cm 9.0 3mm cm 9.0 3mm cm 8.5 3mm cm 8.5 3mm cm 9.5 3mm cm Z-Tip 8.5 3mm cm Z-Tip (Heavy Duty) 8.5 3mm cm XTB 6.5 3mm cm Z-Tip (Heavy Duty) 8.5 3mm cm XTB/Z-Tip 6.5 3mm cm 8.5 3mm cm 9.5 3mm cm Z-Tip 8.5 3mm cm XTB 6.5 3mm cm Z-Tip 8.5 3mm PTFE COATED STAINLESS STEEL DOUBLE ENDED cm Straight & 3mm 8.5/8.5 3mm cm Straight & 1.5mm 8.5/ mm EXCHANGE WIRES - PTFE COATED cm 9.0 3mm cm 8.5 3mm cm 8.5 3mm
16 Interventional Cardiology and Radiology Products Vascular Access Products Argon Range of Standard and Speciality Guidewires Argon Guidewires - Speciality Diameter (inch) Length (cm) Core Taper (cm) Tip Curve Radius Box Contents (Units) Product FIXED CORE - STAINLESS STEEL cm 9.0 3mm cm 9.0 3mm cm 8.5 3mm cm 8.5 3mm cm 8.5 3mm FIXED CORE - STAINLESS STEEL DOUBLE ENDED cm Straight & 3mm 9.0 3mm cm Straight & 3mm 8.5 3mm cm Straight & 3mm 8.5 3mm cm Straight & 3mm 8.5/8.9 3mm cm Straight & 3mm 8.5/8.5 3mm FIXED CORE - BENTSON CEREBRAL WIRES - PTFE COATED cm E cm cm C MOVEABLE CORE PTFE COATED cm Straight Standard cm Standard 3mm cm Tapered 9.0 3mm cm Standard 3mm cm Tapered 5.5 3mm cm Heavy Duty Standard 3mm cm Standard 3mm
17 Fluid Management Systems Argon Range of Manifolds and High Pressure Injection Lines Argon Range of Manifolds & High Pressure Injection Lines for Optimal Fluid Control during Left Heart Studies, Coronary Injections, Arteriograms/Venograms and other Radiological Procedures With choice of Open or Finger grip (Block) design, with 2, 3 or 4 valve ports, all Argon Manifolds have Left or Right rotating adapter to best meet specific procedural needs and physician preferences. Manifold valves with tight tolerances, low torque and smooth port rotation. Choice of Open or Block body design and clear polycarbonate body for easy bubble visualisation, the manifolds construction will withstand injections and are rated at 500 psi. Threaded ISO standard luer fittings with funnelled tapered ports to minimise bubble entrapment. Celcon taps for smooth rotation movement, with positive handle stops and labelled handles for easy identification. Manifold Distal Rotating Adapter facilitates easy catheter manipulation. Argon High Pressure Injection Lines are available in clear, semi-rigid PVC and Flexible Braided Polyurethane with or without Rotating Adapter. Argon High Pressure Injection Lines are designed to provide optimal flexibility, easy debubbling and secure connections and are rated up to 1200 psi. See product table on next page. Argon Range of Manifolds & High Pressure Injection Lines Set Contents: Single packed, sterile product. Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 5 years
18 Fluid Management Systems Argon Range of Manifolds and High Pressure Injection Lines Argon 500 psi Manifolds No. of Ports Open/Block Body Handles (On/Off) Box Contents (Units) Product RIGHT ORIENTATION 500 PSI MANIFOLDS WITH ROTATING ADAPTER 2 Port Open On Port Open Off Port Block On Port Block Off Port Open On Port Open Off Port Block On Port Block Off Port Open On Port Open Off Port Block On LEFT ORIENTATION 500 PSI MANIFOLDS WITH ROTATING ADAPTER 2 Port Open Off Port Open Off Port Block Off RIGHT ORIENTATION 500 PSI MANIFOLDS WITH 15CM TUBING EXTENSION 2 Port Block On Port Block Off Port Block On Argon 1200 psi High Pressure Injection Lines 25cm 50cm 76cm 122cm 152cm 183cm 244cm Box Contents (Units) FLEXIBLE BRAIDED HIGH PRESSURE INJECTION LINES Male to Female Rotating Adapter CLEAR PVC HIGH PRESSURE INJECTION LINES Male to Female Rotating Adapter
19 Fluid Management Systems Argon Range of Control Syringes Argon Range of Control Syringes for Optimal Fluid Control during Left Heart Studies, Coronary Injections, Arteriograms/Venograms and other Radiological Procedures Argon Control Syringes 10ml 12ml 10ml Soft Touch 12ml Soft Touch 10ml Dosage Control 12ml Dosage Control Box Contents (Units) THUMB RING/FINGER RINGS Rotating Adapter Fixed Male Luer THUMB RING/FINGER GRIPS Rotating Adapter Fixed Male Luer 25 PALM PAD/FINGER RINGS Rotating Adapter Fixed Male Luer PALM PAD/FINGER GRIPS Rotating Adapter Fixed Male Luer With choice of Thumb Ring or Palm Pad design, Finger Ring vs Finger Grip, and 10cc vs 12cc volume options, there is an Argon Control Syringe available to best suit most Clinical Needs and hand sizes. The low friction plunger provides for a smooth injection whilst bold volume markings facilitate accurate volume injections. Clear polycarbonate body provides a sturdy syringe able to withstand any hand pressure whilst facilitating for easy bubble visualisation. Fixes luer designed for correct orientation of syringe to manifold with rotating adapter options offering flexibility during manipulation. Thumb ring design facilitates aspirations and injections whilst choice of finger grip or ring style to meet most clinical needs. Choice of Palm Pad designs, including soft touch options, allows for full force palm injections. 10cc or 12cc volume options for larger handed use, Argon Standard Control Syringes have a reservoir area reducing risk of accidental air injection. Argon Dosage Control syringes help in preventing the over-injection of contrast media during angiography studies and facilitate in contrast media conservation. Argon Range of Control Syringes Contents: Single packed, sterile product. Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 5 years (maximum)
20 Fluid Management Systems Argon Range of Colour d Medication Syringes Argon Range of Colour d Medication Syringes Medication Syringes 10ml Blue Yellow Red White Light Green Dark Green Purple Box Contents (Units) UNPRINTED MEDICATION SYRINGES (10ML) Each package includes: clear adhesive labels, printed in black with common injectables. Labels: Lidocaine, Heparin/Saline, Heparin, Contrast, Nitroglycerine and Blank (2 each). PRE-PRINTED MEDICATION SYRINGES (10ML) Contrast Lidocaine Saline Nitro Heparin Flush Available in both unprinted and pre-printed versions, Argon Colour d Medication Syringes are latex free with clear 10cc polycarbonate, APS colour coded plunger and silicone rubber stopper to facilitate in the safe administration of medication. Argon Range of Colour d Medication Syringes Contents: Each Unprinted Medication Syringe package includes: clear adhesive labels, printed in black with common injectables. Labels: Lidocaine, Heparin/Saline, Heparin, Contrast, Nitroglycerine and Blank (2 each). Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 5 years (maximum)
21 Peripherally Inserted Central Catheters (PICC and Midline Catheters) Argon Extended Dwell Catheter Products The Argon family of PICC & Midline catheters and Introducer systems provides you with the best tools designed to make the infusion therapy process simple, safe, and reliable. Argon L-Cath TM Polyurethane PICC and Midline Catheters Argon L-Cath TM Polyurethane PICC and Midline Catheters are intended to provide optimal outcomes for Long-Term and Intermediate Therapies. Argon L-Cath TM PICC and Midline Catheters are designed for safe and easy placement. Polyurethane catheter material provides catheter strength and increased flow rates. Breadth of line offers access options for neonate to geriatric patient populations. Pre-attached Y-site connector allows flushing of catheter before, during, and after the insertion. Protective sleeve, designed to minimise accidental contamination of the catheter. Catheter trim tool is designed to ensure clean and accurate 90 trimming. Latex and DEHP free, Argon L-Cath TM Polyurethane PICC and Midline Catheters are Pressure Rated with a Maximum Pressure Tolerance of 40 psi. Argon First PICC TM Silicone PICC and Midline Catheters Argon First PICC TM and First Midcath TM high-quality silicone catheters designed for safe and easy placement. Soft silicone integrated extension set intended to enhance patient comfort and provide increased mobility. Breadth of line offers access options for neonate to geriatric patient populations. Pre-attached T-port extension allows flushing of the catheter before and after insertion. Hydrophilic stylet for smooth stylet removal. Protective sleeve designed to minimise accidental contamination of the catheter. Numbered catheter cm depth markings designed to allow easy measurement and catheter trimming prior to insertion. Catheter trim tool is designed to ensure clean and accurate 90 trimming. Latex and DEHP free, Argon First PICC TM and First Midcath TM high-quality silicone catheters are Pressure Rated with a Maximum Pressure Tolerance of 40 psi. Argon L-Cath TM PICC and First PICC TM are Class lll according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Argon L-Cath TM Midline and First Midcath TM are Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 3 years (maximum)
22 Peripherally Inserted Central Catheters (PICC and Midline Catheters) Argon PICC and Midline Catheter Introducer Systems Argon Splittable Needle Introducer and Safety MST Sets Gauge Content (Units) Product 1.2Fr (28G) Splittable Needle Introducer Fr (16G) Safety MST Accessory Set Fr (18G) Safety MST Accessory Set Fr (20G) Safety MST Accessory Set Argon Splittable Needle Introducer and Safety MST Sets Argon Splittable Needle Introducer for placement of 1.2Fr (28G) Catheters. Argon Safety MST Accessory Sets for PICC and Midline Placement Using the Modified Seldinger Technique (MST). For placement of 3Fr (20G), 4Fr (18G) and 5Fr (16G) PICC and Midline Catheters. The Insyte TM Autoguard TM Shielded IV Catheter provides safe catheter introduction and reduced needlestick rish using the BD Autoguard TM needle-shielding technology. The Echogenic-tipped, protected needle provides safety needle-introduction when an ultrasound placement is preferred. Clearly identified 5cm guidewire markings for easy determination of guidewire insertion length. Lubricated, tapered-tip splittable sheath and dilator, designed to decrease insertion force and facilitate easier insertion with less trauma to the patient. Inner sterile package minimises accidental contamination risk of kit components. Bard-Parker TM safety-engineered protected disposable scalpel. Argon Splittable Needle Introducer contents: Argon steel needle introducer with splittable technology. Argon PICC and Midline Catheter Introducer Set Contents: Insyte TM Autoguard TM shielded IV catheter; Echogenic-tipped, protected Safety needle Introducer; Soft-tipped guidewire; 5ml Syringe; Peel-away sheath and matched dilator; safety-engineered protected disposable scalpel. Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 3 years Note: Stand-alone 1.9Fr (26G) to 5Fr (16G) BD Introsyte TM and Introsyte TM Autoguard TM Shielded Introducers are available via your local BD Agent. These BD Introsyte TM and Introsyte TM Autoguard TM introducers incorporate the BD Autoguard TM needle-shielding technology.
23 Peripherally Inserted Central Catheters (PICC and Midline Catheters) Argon L-Cath TM Polyurethane PICC and Midline Catheters Argon L-Cath TM Polyurethane PICC and Midline Catheters Gauge Length (cm) Content (Units) Product ARGON L-CATH TM POLYURETHANE PICC SINGLE LUMEN CATHETER ONLY 5Fr (16G) 60cm S/L L-Cath TM PICC, Catheter Only Fr (18G) 60cm S/L L-Cath TM PICC, Catheter Only Fr (20G) 60cm S/L L-Cath TM PICC, Catheter Only Fr (26G) 30cm S/L L-Cath TM PICC, Catheter Only ARGON L-CATH TM POLYURETHANE PICC DUAL LUMEN CATHETER ONLY 5Fr (16G) 60cm D/L L-Cath TM PICC, Catheter Only Fr (18G) 60cm D/L L-Cath TM PICC, Catheter Only Fr (20G) 60cm D/L L-Cath TM PICC, Catheter Only ARGON L-CATH TM POLYURETHANE MIDLINE SINGLE LUMEN CATHETER ONLY 3.5Fr (18G) 20cm S/L L-Cath TM Midline, Catheter Only Fr (20G) 20cm S/L L-Cath TM Midline, Catheter Only ARGON L-CATH TM POLYURETHANE PICC SINGLE LUMEN BASIC KIT WITH BD INTROSYTE TM AUTOGUARD TM SHIELDED INTRODUCER 5Fr (16G) 60cm S/L L-Cath TM PICC Basic Kit with BD Introsyte TM Autoguard TM Fr (18G) 60cm S/L L-Cath TM PICC Basic Kit with BD Introsyte TM Autoguard TM Fr (20G) 60cm S/L L-Cath TM PICC Basic Kit with BD Introsyte TM Autoguard TM ARGON L-CATH TM POLYURETHANE PICC SINGLE LUMEN BASIC KIT WITH ARGON SPLITTABLE NEEDLE INTRODUCER 1.2Fr (28G) 25cm S/L L-Cath TM PICC Basic Kit with Splittable Needle Introducer ARGON L-CATH TM POLYURETHANE PICC DUAL LUMEN BASIC KIT WITH BD INTROSYTE TM AUTOGUARD TM SHIELDED INTRODUCER 5Fr (16G) 60cm D/L L-Cath TM PICC Basic Kit with BD Introsyte TM Autoguard TM Fr (18G) 60cm D/L L-Cath TM PICC Basic Kit with BD Introsyte TM Autoguard TM Fr (20G) 60cm D/L L-Cath TM PICC Basic Kit with BD Introsyte TM Autoguard TM ARGON L-CATH TM POLYURETHANE MIDLINE SINGLE LUMEN BASIC KIT WITH BD INTROSYTE TM AUTOGUARD TM SHIELDED INTRODUCER 3.5Fr (18G) 20cm S/L L-Cath TM Midline Basic Kit with BD Introsyte TM Autoguard TM Fr (20G) 20cm S/L L-Cath TM Midline Basic Kit with BD Introsyte TM Autoguard TM Argon L-Cath TM Polyurethane PICC and Midline Catheter-Only Set contents: Polyurethane Catheter with 1cm depth markings; Catheter Cutting tool; Paper tape measure with 1cm measurement. Argon L-Cath TM Polyurethane PICC and Midline Basic Kit Set contents: BD Introsyte TM Autoguard TM Shielded Introducer; Polyurethane Catheter with 1cm depth markings; Catheter Cutting tool; Paper tape measure with 1cm measurement. Argon L-Cath TM 1.2Fr (28G) Polyurethane PICC Basic Kit Set contents: Argon 1.2Fr (28G) Splittable Needle Introducer; Polyurethane Catheter with 1cm depth markings; Catheter Cutting tool; Paper tape measure with 1cm measurement. Note: Stand-alone 1.9Fr (26G) to 5Fr (16G) BD Introsyte TM and Introsyte TM Autoguard TM Shielded Introducers are available via your local BD Agent. These BD Introsyte TM and Introsyte TM Autoguard TM introducers incorporate the BD Autoguard TM needle-shielding technology.
24 Peripherally Inserted Central Catheters (PICC and Midline Catheters) Argon First PICC TM Silicone PICC and Midline Catheters Argon First PICC TM Silicone PICC and Midline Catheters Gauge Length (cm) Content (Units) Product ARGON First PICC TM SILICONE PICC SINGLE LUMEN CATHETER ONLY 5Fr (16G) 65cm S/L First PICC TM, Catheter Only Fr (18G) 65cm S/L First PICC TM, Catheter Only Fr (20G) 65cm S/L First PICC TM, Catheter Only Fr (22G) 50cm S/L First PICC TM, Catheter Only Fr (26G) 50cm S/L First PICC TM, Catheter Only ARGON First PICC TM SILICONE PICC DUAL LUMEN CATHETER ONLY 5Fr (16G) 65cm D/L First PICC TM, Catheter Only ARGON First MIDCATH TM SILICONE MIDLINE SINGLE LUMEN CATHETER ONLY 4Fr (18G) 20cm S/L First Midcath TM Midline, Catheter Only Fr (20G) 20cm S/L First Midcath TM Midline, Catheter Only ARGON First PICC TM SILICONE PICC SINGLE LUMEN BASIC KIT WITH BD INTROSYTE TM AUTOGUARD TM SHIELDED INTRODUCER 5Fr (16G) 65cm S/L First PICC TM Basic Kit with BD Introsyte TM Autoguard TM Fr (18G) 65cm S/L First PICC TM Basic Kit with BD Introsyte TM Autoguard TM Fr (20G) 65cm S/L First PICC TM Basic Kit with BD Introsyte TM Autoguard TM ARGON First PICC TM SILICONE PICC SINGLE LUMEN BASIC KIT WITH BD INTROSYTE-N TM INTRODUCER 1.9Fr (26G) 50cm S/L First PICC TM Basic Kit with BD Introsyte-N TM Introducer ARGON First PICC TM SILICONE PICC DUAL LUMEN BASIC KIT WITH BD INTROSYTE TM AUTOGUARD TM SHIELDED INTRODUCER 5Fr (16G) 65cm D/L First PICC TM Basic Kit with BD Introsyte TM Autoguard TM ARGON First MIDCATH TM SILICONE MIDLINE SINGLE LUMEN BASIC KIT WITH BD INTROSYTE TM AUTOGUARD TM SHIELDED INTRODUCER 4Fr (18G) 20cm S/L First Midcath TM Midline Basic Kit with BD Introsyte TM Autoguard TM Fr (20G) 20cm S/L First Midcath TM Midline Basic Kit with BD Introsyte TM Autoguard TM Argon First PICC TM Silicone PICC and Midline Catheter-Only Set contents: Silicone Catheter with 1cm depth markings; Catheter Cutting tool; Paper tape measure with 1cm measurement. Argon First PICC TM Silicone PICC and Midline Basic Kit Set contents: BD Introsyte TM Autoguard TM Shielded Introducer; Silicone Catheter with 1cm depth markings; Catheter Cutting tool; Paper tape measure with 1cm measurement. Argon First PICC TM 1.9Fr (26G) Silicone PICC Basic Kit Set contents: BD Introsyte-N TM 1.9Fr (26G) Introducer; Silicone Catheter with 1cm depth markings; Catheter Cutting tool; Paper tape measure with 1cm measurement. Note: Stand-alone 1.9Fr (26G) to 5Fr (16G) BD Introsyte TM and Introsyte TM Autoguard TM Shielded Introducers are available via your local BD Agent. These BD Introsyte TM and Introsyte TM Autoguard TM introducers incorporate the BD Autoguard TM needle-shielding technology.
25 Central Venous Catheters Argon Floswitch TM Content (Units) Product Argon Connecta Floswitch TM 25/ Argon Floswitch TM acts as an ON/OFF device on infusion lines, stopping the flow in order to carry out line procedures in closed circuit. Reduces the risk of patient emboli and potential contamination of hospital staff by exposure to blood. The Floswitch TM therefore considerably increases safety. Argon Floswitch TM can be connected to any catheter fitted with a Luer connector. Winged to facilitate attachment. Floswitch TM closed External compression of the extension tubing by means of a steel ball, provides risk-free unambiguous opening and closing of the infusion line. Floswitch TM open Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 5 years
26 Central Venous Catheters Argon Secalon-T TM Gauge Length Catheter External Diameter Colour Content (Units) Flow Rate (ml/min) Product 18G 90mm 1.2mm Green 25/ G 130mm 1.7mm Grey 25/ G 160mm 1.7mm Grey 25/ G 160mm 2.0mm Orange 25/ Argon Secalon-T TM emergency catheter designed for high flow rate infusions. FEP (Fluorinated Ethylene Propylene) material construction and incorporating a Floswitch TM, Argon Secalon-T TM is ideal for rapid short-term insertion into central veins or large peripheral vessels. Complete kit contains pre-puncture stylus and stabilising wing. Class lll according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 5 years (maximum)
27 Central Venous Catheters Argon Careflow TM Single Lumen Central Venous Catheters External Diameter Length Cannula Introducer Floswitch TM Introducer Needle Introducer Guidewire OD & Gauge Length Gauge Length Gauge Length Length Secondary Fixation (SFD) Content (Units) Flow Rate (ml/min) D without Floswitch TM with Floswitch TM ARGON CAREFLOW TM SINGLE LUMEN SETS WITHOUT EXTENSION 2.5Fr (22G) 100mm N/A N/A 20G 45mm 22G 40mm 0.5 x 350mm 10/ Fr (20G) 150mm N/A N/A 20G 45mm 22G 40mm 0.5 x 350mm 10/ Fr (20G) 200mm N/A N/A 20G 45mm 22G 40mm 0.5 x 450mm 10/ Fr (18G) 200mm N/A N/A 18G 60mm 17G 70mm 0.6 x 450mm 10/ Fr (16G) 150mm N/A N/A 15G 70mm 17G 70mm 0.9 x 450mm Yes 10/ Fr (16G) 200mm N/A N/A 15G 70mm 17G 70mm 0.9 x 450mm Yes 10/ Fr (14G) 150mm N/A N/A 14G 70mm 17G 70mm 0.9 x 450mm Yes 10/ Fr (14G) 200mm N/A N/A 14G 70mm 17G 70mm 0.9 x 450mm Yes 10/ Argon Careflow TM is a range of paediatric and adult polyurethane central venous catheters designed for catheterisation by the Seldinger technique. Available in single, double, triple, quadruple and quint lumen formats, this range of sets contains a NiTiNol guidewire and the Argon Venaguide TM Seldinger wire advancing device facilitating single handed guidewire insertion. Argon Careflow TM catheters are latex free with tapered atraumatic catheter tip reducing the risk of venous damage and improving catheter insertion. The streamlined junction hub enables ease of catheter suture and comfortable positioning on the patients skin. Argon Careflow TM catheters offer 1cm and 5cm interval depth markings to facilitate catheter placement and clear lumen size and hub colour coding indication. Argon Floswitch TM and Argon Floswitch TM introducer catheter options available throughout range. Argon Careflow TM central venous catheters are pressure rated with a maximum pressure tolerance of 45 psi. Single lumen Argon Careflow TM with Argon Floswitch TM set contents: Argon Careflow TM Polyurethane catheter, steel needle introducer, Argon Floswitch TM overneedle introducer, vessel dilator, Argon Venaguide TM Seldinger wire advancing device with NiTiNol guidewire, Argon Floswitch TM revolving Luer-Lok TM system, luer lock plug and secondary fixation device (where shown). Single lumen Argon Careflow TM without Argon Floswitch TM set contents: Argon Careflow TM Polyurethane catheter, steel needle introducer, vessel dilator, Argon Venaguide TM Seldinger wire advancing device with NiTiNol guidewire and secondary fixation device (where shown). Note: Part number contains 0.5 x 450mm guidewire. Class lll according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 5 years
28 Central Venous Catheters 1 2 Argon Careflow TM Single Lumen Central Venous Catheter Sets 3 4 External Diameter Length Cannula Introducer Floswitch TM Introducer Needle Introducer Guidewire OD & Gauge Length Gauge Length Gauge Length Length Secondary Fixation (SFD) Content (Units) Flow Rate (ml/min) D without Floswitch TM with Floswitch TM 1. ARGON CAREFLOW TM SINGLE LUMEN SETS WITH EXTENSION 2.5Fr (22G) 60mm 22G 38mm N/A N/A 22G 40mm 0.5 x 350mm 5/ Fr (22G) 100mm 22G 38mm N/A N/A 22G 40mm 0.5 x 350mm 5/ Fr (22G) 200mm 22G 38mm N/A N/A 22G 40mm 0.5 x 650mm 5/ Fr (20G) 150mm 20G 45mm N/A N/A 22G 40mm 0.5 x 450mm 5/ Fr (20G) 200mm 20G 45mm N/A N/A 22G 40mm 0.5 x 650mm 5/ Fr (18G) 60mm 20G 45mm N/A N/A 22G 40mm 0.5 x 350mm 5/ Fr (18G) 200mm 20G 45mm N/A N/A 22G 40mm 0.5 x 650mm 5/ Fr (16G) 150mm 16G 70mm N/A N/A 17G 70mm 0.9 x 450mm Yes 5/ Fr (16G) 200mm 16G 70mm N/A N/A 17G 70mm 0.9 x 700mm Yes 5/ Fr (16G) 300mm 16G 70mm N/A N/A 17G 70mm 0.9 x 700mm Yes 5/ Fr (14G) 150mm 16G 70mm N/A N/A 17G 70mm 0.9 x 450mm Yes 5/ Fr (14G) 200mm 16G 70mm N/A N/A 17G 70mm 0.9 x 700mm Yes 5/ Fr (14G) 300mm 16G 70mm N/A N/A 17G 70mm 0.9 x 700mm Yes 5/ ARGON CAREFLOW TM SINGLE LUMEN SET WITH ARGON FLOSWITCH TM 2.5Fr (22G) 200mm N/A N/A 20G 45mm 22G 40mm 0.5 x 450mm 10/ ARGON CAREFLOW TM SINGLE LUMEN WITH INTEGRAL ARGON FLOSWITCH TM 5Fr (16G) 150mm N/A N/A 15G 70mm 17G 70mm 0.9 x 450mm Yes 10/ Fr (16G) 200mm N/A N/A 15G 70mm 17G 70mm 0.9 x 700mm Yes 10/ Fr (16G) 300mm N/A N/A 15G 70mm 17G 70mm 0.9 x 700mm Yes 10/ ARGON CAREFLOW TM SINGLE LUMEN WITH EXTENSION AND ARGON FLOSWITCH TM 2.5Fr (22G) 60mm N/A N/A 20G 45mm 22G 40mm 0.5 x 350mm 5/ Fr (18G) 60mm N/A N/A 20G 45mm 22G 40mm 0.5 x 350mm 5/ Single lumen Argon Careflow TM set with extension contents : Argon Careflow TM Polyurethane catheter with clear extension, extension slide clamp, cannula introducer, steel needle introducer, vessel dilator, Argon Venaguide TM Seldinger wire advancing device with NiTiNol guidewire, Argon Luer-Lok TM plug, secondary fixation device (where shown) and 5ml syringe. 2. Single lumen Argon Careflow TM set with Argon Floswitch TM contents: Argon Careflow TM Polyurethane catheter with clear extension, steel needle introducer, Argon Floswitch TM overneedle introducer, PTFE coated soft-tip straight guidewire and Argon Floswitch TM revolving Luer-Lok TM system, luer lock plug. 3. Single lumen Argon Careflow TM set with integral Argon Floswitch TM contents : Argon Careflow TM Polyurethane catheter with clear extension and integral Argon Floswitch TM, Argon Floswitch TM overneedle introducer, steel needle introducer, vessel dilator, Argon Venaguide TM Seldinger wire advancing device with NiTiNol guidewire, Argon Luer-Lok TM plug and secondary fixation device. 4. Single lumen Argon Careflow TM set with extension and Argon Floswitch TM contents : Argon Careflow TM Polyurethane catheter with clear extension, steel needle introducer, Argon Floswitch TM overneedle introducer, vessel dilator, Argon Venaguide TM Seldinger wire advancing device with NiTiNol guidewire, Argon Floswitch TM revolving Luer-Lok TM system and luer lock plug. Sterile double tray packaging for increased safety Shelf life: 5 years Class lll according to the European Medical Devices Directive ( except , & which have a 3 year shelf life.) 93/42/EEC as amended by Directive 2007/47/EC
29 Central Venous Catheters Argon Careflow TM Double & Triple Lumen Central Venous Catheter Sets External Diameter Length Cannula Introducer Floswitch TM Introducer Needle Introducer Guidewire OD & Gauge Length Gauge Length Gauge Length Length Secondary Fixation (SFD) Content (Units) Flow Rate (ml/min) D M P without Floswitch TM with Floswitch TM ARGON CAREFLOW TM DOUBLE LUMEN SETS 4Fr (20G, 22G) 60mm 20G 45mm 20G 45mm 22G 40mm 0.5 x 350mm 5/ Fr (20G, 22G) 100mm 20G 45mm 20G 45mm 22G 40mm 0.5 x 350mm 5/ Fr (20G, 22G) 150mm 20G 45mm 20G 45mm 22G 40mm 0.5 x 450mm 5/ Fr (20G, 22G) 200mm 20G 45mm 20G 45mm 22G 40mm 0.5 x 450mm 5/ Fr (18G, 20G) 60mm 18G 60mm 18G 60mm 17G 70mm 0.6 x 450mm Yes 5/ Fr (18G, 20G) 150mm 18G 60mm 18G 60mm 17G 70mm 0.6 x 450mm Yes 5/ Fr (18G, 20G) 200mm 18G 60mm 18G 60mm 17G 70mm 0.6 x 650mm Yes 5/ Fr (16G, 18G) 150mm 16G 70mm 15G 70mm 17G 70mm 0.9 x 450mm Yes 5/ Fr (16G, 18G) 200mm 16G 70mm 15G 70mm 17G 70mm 0.9 x 700mm Yes 5/ Fr (16G, 18G) 300mm 16G 70mm 15G 70mm 17G 70mm 0.9 x 700mm Yes 5/ Double lumen Argon Careflow TM with Argon Floswitch TM set contents: Argon Careflow TM double lumen Polyurethane catheter with clear extensions, steel needle introducer, Argon Floswitch TM overneedle introducer, vessel dilator, Argon Venaguide TM Seldinger wire advancing device with NiTiNol guidewire, Argon Floswitch TM revolving Luer-Lok TM system, luer lock plugs and secondary fixation device (where shown). Double lumen Argon Careflow TM without Argon Floswitch TM set contents: Argon Careflow TM double lumen Polyurethane catheter with clear extensions, cannula introducer, steel needle introducer, vessel dilator, Argon Venaguide TM Seldinger wire advancing device with NiTiNol guidewire, extension slide clamps, 5ml syringe, luer lock plugs and secondary fixation device (where shown). Note: Part number contains 0.5 x 650mm guidewire. External Diameter Length Cannula Introducer Floswitch TM Introducer Needle Introducer Guidewire OD & Gauge Length Gauge Length Gauge Length Length Secondary Fixation (SFD) Content (Units) Flow Rate (ml/min) D M P without Floswitch TM with Floswitch TM ARGON CAREFLOW TM TRIPLE LUMEN SETS 5Fr (18G, 20G, 20G) 60mm 18G 60mm 18G 60mm 17G 70mm 0.6 x 450mm Yes 5/ Fr (18G, 20G, 20G) 100mm 18G 60mm 18G 60mm 17G 70mm 0.6 x 450mm Yes 5/ Fr (18G, 20G, 20G) 150mm 18G 60mm 18G 60mm 17G 70mm 0.6 x 450mm Yes 5/ Fr (18G, 20G, 20G) 200mm 18G 60mm 18G 60mm 17G 70mm 0.6 x 650mm Yes 5/ Fr (16G, 18G, 18G) 150mm 16G 70mm 15G 70mm 17G 70mm 0.9 x 450mm Yes 5/ Fr (16G, 18G, 18G) 200mm 16G 70mm 15G 70mm 17G 70mm 0.9 x 700mm Yes 5/ Fr (16G, 18G, 18G) 300mm 16G 70mm 15G 70mm 17G 70mm 0.9 x 700mm Yes 5/ Triple lumen Argon Careflow TM with Argon Floswitch TM set contents: Argon Careflow TM triple lumen Polyurethane catheter with clear extensions, steel needle introducer, Argon Floswitch TM overneedle introducer, vessel dilator, Argon Venaguide TM Seldinger wire advancing device with NiTiNol guidewire, Argon Floswitch TM revolving Luer-Lok TM system, luer lock plugs and secondary fixation device. Triple lumen Argon Careflow TM without Argon Floswitch TM set contents: Argon Careflow TM triple lumen Polyurethane catheter with clear extensions, cannula introducer, steel needle introducer, vessel dilator, Argon Venaguide TM Seldinger wire advancing device with NiTiNol guidewire, extension slide clamps, 5ml syringe, luer lock plugs and secondary fixation device. Shelf life: 5 years Class lll according to the European Medical Devices Sterile double tray packaging for increased safety Directive 93/42/EEC as amended by Directive 2007/47/EC
30 Central Venous Catheters Argon Careflow TM Quad & Quint Lumen Central Venous Catheter Sets External Diameter Length Cannula Introducer Floswitch TM Introducer Needle Introducer Guidewire OD & Content Flow Rate (ml/min) Gauge Length Gauge Length Gauge Length Length (Units) D M1 M2 P1 P2 without Floswitch TM with Floswitch TM ARGON CAREFLOW TM QUAD LUMEN SETS 8.5Fr (14G, 16G, 16G, 18G) 150mm 16G 70mm 15G 70mm 17G 70mm 0.9 x 450mm 5/ Fr (14G, 16G, 16G, 18G) 200mm 16G 70mm 15G 70mm 17G 70mm 0.9 x 700mm 5/ Quad lumen Argon Careflow TM with Argon Floswitch TM set contents: Argon Careflow TM quad lumen Polyurethane catheter with clear extensions, steel needle introducer, Argon Floswitch TM overneedle introducer, vessel dilator, Argon Venaguide TM Seldinger wire advancing device with NiTiNol guidewire, Argon Floswitch TM revolving Luer-Lok TM system, scalpel, luer lock plugs and secondary fixation device. Quad lumen Argon Careflow TM without Argon Floswitch TM set contents: Argon Careflow TM quad lumen Polyurethane catheter with clear extensions, cannula introducer, steel needle introducer, vessel dilator, Argon Venaguide TM Seldinger wire advancing device with NiTiNol guidewire, extension slide clamps, 5ml syringe, scalpel, luer lock plugs and secondary fixation device. External Diameter Length Cannula Introducer Floswitch TM Introducer Needle Introducer Guidewire OD & Content Flow Rate (ml/min) Gauge Length Gauge Length Gauge Length Length (Units) D M1 M2 P1 P2 without Floswitch TM with Floswitch TM ARGON CAREFLOW TM QUINT LUMEN SETS 9.5Fr (14G, 16G, 16G, 18G, 18G) 150mm 16G 70mm 15G 70mm 17G 70mm 0.9 x 450mm 5/ Fr (14G, 16G, 16G, 18G, 18G) 200mm 16G 70mm 15G 70mm 17G 70mm 0.9 x 700mm 5/ Quint lumen Argon Careflow TM with Argon Floswitch TM set contents: Argon Careflow TM quint lumen Polyurethane catheter with clear extensions, steel needle introducer, Argon Floswitch TM overneedle introducer, vessel dilator, Argon Venaguide TM Seldinger wire advancing device with NiTiNol guidewire, Argon Floswitch TM revolving Luer-Lok TM system, scalpel, luer lock plugs and secondary fixation device. Quint lumen Argon Careflow TM without Argon Floswitch TM set contents: Argon Careflow TM quint lumen Polyurethane catheter with clear extensions, cannula introducer, steel needle introducer, vessel dilator, Argon Venaguide TM Seldinger wire advancing device with NiTiNol guidewire, extension slide clamps, 5ml syringe, scalpel, luer lock plugs and secondary fixation device. Class lll according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 5 years Sterile double tray packaging for increased safety
31 Central Venous Catheters Argon Hydrocath Assure TM Antimicrobial Coated Central Venous Catheters External Diameter Length Cannula Introducer Floswitch TM Introducer Needle Introducer Guidewire OD & Gauge Length Gauge Length Gauge Length Length Secondary Fixation (SFD) Content (Units) Flow Rate (ml/min) D M2 P2 without Floswitch TM with Floswitch TM ARGON HYDROCATH ASSURE TM SINGLE LUMEN SETS 5Fr (16) 200mm 16G 70mm N/A N/A 17G 70mm 0.9 x 700mm 5/ ARGON HYDROCATH ASSURE TM DOUBLE LUMEN SETS 7Fr (16+18) 200mm 16G 70mm 15G 70mm 17G 70mm 0.9 x 700mm Yes 5/ Fr (16+18) 300mm 16G 70mm 15G 70mm 17G 70mm 0.9 x 700mm Yes 5/ ARGON HYDROCATH ASSURE TM TRIPLE LUMEN SETS 7Fr (16, 18+18) 150mm 16G 70mm 15G 70mm 17G 70mm 0.9 x 450mm Yes 5/ Fr (16, 18+18) 200mm 16G 70mm 15G 70mm 17G 70mm 0.9 x 700mm Yes 5/ Fr (16, 18+18) 300mm 16G 70mm 15G 70mm 17G 70mm 0.9 x 700mm Yes 5/ An innovative approach to risk management: Argon Hydrocath Assure TM is a range of single, double and triple lumen polyurethane central venous catheters, designed for catheterisation by the Seldinger technique. Every catheter is coated with a hydrophilic substance activated by biological fluids, which facilitates the insertion of the catheter and reduces the potential adhesion of bacteria or formation of thrombus. In addition, the Hydromer hydrophilic matrix is impregnated with the antimicrobial agent Benzalkonium Chloride (BZC). BZC is bactericidal against a broad spectrum of microorganisms which are known to colonise central venous catheters. Argon Hydrocath Assure TM has been proven to reduce bacterial colonisation of catheters in critically ill patients 1. All of the above sets contain: BZC impregnated and hydrophilic coated polyurethane catheter, Argon VenaGuide TM Seldinger wire advancing system with NiTiNol guidewire, needle introducer, vein dilator, secondary fixation device as shown and luer lock plugs. All sets without Argon Floswitch TM contain a cannula introducer, needle introducer, sliding clamps and 5ml syringe. All Argon Floswitch TM sets include an Argon Floswitch TM revolving Luer-Lok TM system, Argon Floswitch TM cannula introducer and needle introducer. Class lll according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 5 years Sterile double tray packaging for increased safety 1 Moss MA, Tebbs SE, Faroqui MH, Herbst T, Isaac JL, Brown J, Elliott TSJ, A central venous catheter coated with Benzalkonium Chloride for the prevention of catheterrelated microbial colonisation. Eur J Anaesth 2000, 17,
32 Arterial Catheters Argon Careflow TM Arterial Catheters Product Catheter External Diameter Length Needle Introducer Gauge Length Guidewire OD & Length Content (Units) Priming Volume (ml) Flow Rate (ml/min) Product Radial artery set 2.5Fr (22G) 60mm 22G 40mm 0.5 x 250mm 10/ Radial artery set 3Fr (20G) 60mm 22G 40mm 0.5 x 250mm 10/ Femoral artery set 3Fr (20G) 200mm 22G 40mm 0.5 x 450mm 10/ Femoral artery set 4Fr (18G) 200mm 17G 70mm 0.6 x 450mm 10/ Argon Careflow TM Polyurethane catheters are designed for access to radial or femoral arteries, for the determination of blood parameters or monitoring blood pressure. Catheterisation trays contain an introducer needle, metal guidewire and Luer Lok TM plug. Class lll according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 5 years
33 Pulmonary Artery and Thermodilution Systems Argon Percutaneous Sheath Introducer Sets Argon Exacta TM Percutaneous Sheath Introducers for the Introduction of Pulmonary Artery Catheters. Size* Introducer Length Cannula Introducer Needle Introducer Guidewire OD & Gauge Length Gauge Length Length Contamination Shield Length High-Flow Stopcock Syringe Scalpel Obturator Content (Units) Product 6Fr 110mm 16G 70mm 17G 70mm 0.9 x 450mm 800mm Yes Yes Yes Yes 5/ Fr 110mm 16G 70mm 17G 70mm 0.9 x 450mm 800mm Yes Yes Yes Yes 5/ Fr 110mm 16G 70mm 17G 70mm 0.9 x 450mm 800mm Yes Yes Yes Yes 5/ Link Kit 8.5Fr 110mm 16G 70mm 17G 70mm 0.9 x 450mm - Yes Yes Yes Yes 5/ Fr 110mm 16G 70mm 17G 70mm 0.9 x 450mm 800mm Yes Yes Yes Yes 5/ * for introduction of 1Fr smaller size catheters Argon Tuohy Borst Percutaneous Introducers for the Introduction of Pulmonary Artery Catheters. Size* Introducer Length Guidewire OD & Length Vessel Dilator Stopcock Content (Units) Product 6Fr 110mm x 450mm 6Fr Yes Fr 110mm x 450mm 7Fr Yes Fr 110mm x 450mm 8Fr Yes Fr 110mm x 450mm 8.5Fr Yes Fr 110mm x 450mm 9Fr Yes * for introduction of 1Fr smaller size catheters Accessories Size/Length Content (Units) Product Septishield Catheter Sleeve 800mm Obturator for 5Fr-6Fr x 11cm Introducer Sheaths 5Fr Obturator for 7Fr-9Fr x 11cm Introducer Sheaths 7Fr A complete range of percutaneous sheath introducer systems Radiopaque FEP sheath with integral sidearm Tuohy Borst adapter and haemostasis valve Matched dilator with luer lock collar Individually packed and sterile Argon Exacta TM sets include a contamination shield with Tuohy Borst lock Two separately packaged sterile obturators supplied per box of 5 Argon Exacta TM sheath systems How Argon percutaneous introducers can benefit you Radiopaque FEP sheath reduces risk of thrombus formation in situ Flexible hub minimises potential for kinking of introducers Suture point facilitates skin fixation Profiled sheath tip and matched dilator facilitates smooth, atraumatic insertion Dilator luer locking collar secures dilator to sheath hub during insertion Tuohy Borst adapter minimises catheter migration and improves catheter control, self-sealing haemostasis valve minimises risk of blood loss Argon Exacta TM sets include the Argon Venaguide TM Seldinger wire advancing device which allows single-handed wire insertion Argon Exacta TM sets include sterile double tray packaging for increased safety (except part number which contains latex) Class lll (Exacta) or Class IIa (Tuohy Borst) according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 5 years
34 Pulmonary Artery and Thermodilution Systems Argon Criticath TM Pulmonary Artery Catheters for Monitoring Right Heart Pressures and Cardiac Output Measurements Catheters for Monitoring Right Heart Pressures and Cardiac Output Measurement Model Size Length No. of Lumens PA Wedge Pressure CV Pressure Cardiac Output CVP Medic. port Ventric. placing Heparinised Additional Information Content (Units) Product SP5105H 5Fr 80cm 4 Yes Yes Yes Yes 5/ SP5107 7Fr 110cm 4 Yes Yes Yes No 5/ SP5107H 7Fr 110cm 4 Yes Yes Yes Yes 5/ SP5107H-14 7Fr 110cm 4 Yes Yes Yes Yes Pre-mounted Luer-Lok TM AC shield 5/ SP5107+SP5045 7Fr 110cm 4 Yes Yes Yes No Pre-mounted In-Line Inject, sensor 5/ SP5107H+SP5045 7Fr 110cm 4 Yes Yes Yes Yes Pre-mounted In-Line Inject, sensor 5/ SP5127 7Fr 110cm 4 Yes Yes Yes No S shaped, to facilitate femoral insertion 5/ SP5127H 7Fr 110cm 4 Yes Yes Yes Yes S shaped, to facilitate femoral insertion 5/ SP5507 7Fr 110cm 5 Yes Yes Yes Yes No 5/ SP5507H 7.5Fr 110cm 5 Yes Yes Yes Yes Yes 5/ SP5507H Fr 110cm 5 Yes Yes Yes Yes Yes Pre-mounted Luer-Lok TM AC shield 5/ SP5507HS 7.5Fr 110cm 5 Yes Yes Yes Yes Yes Soft version 5/ SP5507+SP Fr 110cm 5 Yes Yes Yes Yes No Pre-mounted In-Line Inject, sensor 5/ SP Fr 110cm 5 Yes Yes Yes Yes No 5/ SP5537H 7.5Fr 110cm 5 Yes Yes Yes Yes Yes 5/ A range of flow directed, balloon tipped catheters for both adult and paediatric use Use for monitoring right heart pressures and obtaining venous blood samples Thermodilution technique used to measure Cardiac Output Options include temporary ventricular pacing and S tipped for femoral insertion Also available in hard and soft versions Individually packed, sterile and non-pyrogenic How Argon Criticath TM can benefit you Rounded catheter tip design allows for smooth insertion and reduces risk of vessel trauma Heparin coating minimises risk of thrombus formation Strong circular lumen design reduces kinking and enhances pressure signal transfer Catheter depth markings facilitate accurate placement and catheter manipulation Smooth balloon/catheter junction reduces risk of balloon rupture and thrombus formation Some models have a pre-mounted in-line injectate sensor housing or an anticontamination (AC) sheath on the catheter for user convenience Note: pulmonary artery balloon contains latex. Class lll according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 2 years
35 Pulmonary Artery and Thermodilution Systems Argon Critikit TM Ice/Room Temperature Injectate Systems and Accessories Closed Loop In-Line Injectate Systems for Improved Accuracy of Cardiac Output Measurement Model Sterile Content (Units) Product SP4500 Ice/Room temperature Injectate Critikit (with in-line sensor, control syringe & cooling coil) Yes 4/ Ice/Room temperature Injectate Critikit (with in-line sensor and control syringe, without cooling coil) Yes 5/ SP5045 In-line injectate sensor housing Yes 25/ Spectraject 10cc control syringe Yes 10/ Available in both iced and room temperature injectate options Closed circuit design offers an aseptic approach to cardiac output measurement Individually packed, sterile, non-pyrogenic and latex-free Set comprises an injectate sensor housing with three way stopcock, one way check valve, Spectraject 10cc syringe, cooling coil, delivery tubing and IV spike How Argon Critikit TM can benefit you Closed loop system reduces risk of line contamination Insulated volume-restricted syringe facilitates precise and reproducible injectate In-line injectate sensor optimises accuracy of temperature readings Syringe design allows smooth injectate action improving data validity Note: The Critikit TM injectate system and Spectraject control syringe contain latex (Spectraject syringe stopper) Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 5 years Non-Sterile Accessories Model Sterile Content (Units) Product SP4042 SP4043 SP4045 SP4046 In-line injectate sensor cable. For use with Abbott Oximetrix, Arrow, Baxter Edwards 9520A or Com1, Mennen Horizon 2000 Series (cable ), Spacelabs Alpha PC or PCMS (bifurcated cable model ), Datex AS3 and Critikit Injectate set or SP5045 sensor housing. In-line injectate sensor cable. For use with Siemens bifurcated cable, Siemens Pod system (Model ) and Critikit Injectate set or SP5045 sensor housing. In-line injectate sensor cable. For use with HemoPro (SP1445), Nikon Kohden, Spacelabs (bifurcated cable model ), Fukuda Denshi IB5006 (DSCP), Dynascope DS3300 and Critikit Injectate set or SP5045 sensor housing. In-line injectate sensor cable. For use with Hewlett Packard Cardiac Output Module (HP trifurcated cable M1641A or M1642A) and Critikit Injectate set or SP5045 sensor housing. No No No No Class l according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC
36 Disposable Pressure Transducer Argon DTX Plus TM Disposable Pressure Transducer Sets Designed for ease of use and minimal wavelength distortion Haemodynamic monitoring information is used to manage the care of critically ill patients. It is therefore essential that you are confident about the accuracy of the information that you are using. Fluid filled pressure monitoring systems will cause some distortion to the pressure waveform. Up to 40% distortion has been shown in some cases. 1 Accuracy in pressure monitoring isn t just dependent on the transducer, it s dependent on all the components in the pressure monitoring system; catheter, pressure tubing, monitor filter and stopcocks. It has been shown 2 that in order to know the accuracy of your system, you need to consider the performance of the total chain where all the components are linked together. As a manufacturer we believe we have a responsibility to provide you with PRESSURE OUT information about the accuracy of the whole monitoring system, not just the PRESSURE IN TESTED SET transducer. Therefore, Argon has selected a range of standard Argon DTX ACCEPTED Plus TM sets which are Gabarith tested. 2 AS WITHIN GABARITH WINDOW GABARITH The Argon Gabarith TM WINDOW OF test remains the only scientific technique that provides TOLERANCE information about the dynamic response performance of the total pressure TESTED SET DISCARDED 1 AS OUTSIDE monitoring system (total chain). DYNAMIC GABARITH The Argon Gabarith TM test assesses the system against pre-set windows of error (2%, 5% and 10% waveform distortion). For example: If the dynamic response of a pressure chain falls within the 10% Gabarith window then we know the pressure waveform will not be distorted by more than 10%. 3 Windows of tolerance are based on catheter tip sensor results (the gold standard) using real patient data. Every box of Argon DTX Plus TM pressure monitoring sets is stamped with the Argon Gabarith TM symbol. This shows that the set has passed the Argon Gabarith TM test and has a known level of accuracy. The Argon Gabarith TM test exceeds the demands of the AAMI standard (Association for the Advancement of Medical Instrumentation). RESPONSE Hz Example of Radial Artery pressure 10% error Gabarith window (for adult kit) WINDOW References: 1 Anesthesiology 53: , 1980; British Journal of Anaesthesia 1987, 59, ; European Academy of Anaesthesiology - Strasbourg Aug/Sep 1997 (Bender HJ, Billiet E et al). 2 Billiet E, Colardyn F. (1998) Pressure Measurement Evaluation and Accuracy: The Gabarith Test. Intensive Care Medicine 24: Assuming that the set has been set up and zeroed in accordance with manufacturing instructions Argon DTX Plus TM Disposable Pressure Transducer Sets Specifications Detail Environmental performance: a) storage temperatures b) operating temperatures c) humidity d) atmospheric pressure Pressure range: a) operating pressure b) overpressure withstand Mounting requirement: Frequency response (Stand-alone Transducer): Transducer excitation: Argon DTX Plus TM specifications -25ºC to 70ºC 15ºC to 40ºC 10% to 90% 425 to 850 torr -30 to 300 mmhg -700 to 7,755 mmhg Will meet performance requirements when mounted on any axis 15% bandwidth shall be >200 Hz DC to 5,000 Hz 4 to 8 V RMS Phase shift: <5 Transducer excitation impedance (input impedance): Transducer signal impedance (output impedance): >200 ohms <3,000 ohms Transducer symmetry: ±5% Nominal sensitivity (gain): Unbalance (zero balance): Accuracy: Risk current: Defibrillator withstand: Requirements for the cable: a) cable length stated b) transducer venting to atm. c) cable will withstand five repeated discharges in 5 minutes of 360J sinusoidal energy delivered into 50 ohms when all wires are shorted and foil surrounds the cable Flow Rate, DTX Plus transducers: Fast Flush Rate, DTX Plus transducers: DTX Plus Transducer dimensions (inc Flush and Zero stopcock): 5 µv/v/mmhg ±40 mmhg The maximum error due to the total effects of nonlinearity, hysteresis and sensitivity variations shall be no more than 2% of the reading or ±1 mmhg, whichever is greater, over the operating range. <2µA Withstand five repeated discharges in 5 minutes of 400J sinusoidal energy delivered into 50 ohms when all transducer wires are shorted and saline is in fluid column Cable length stated Venting to atmosphere Withstand five repeated discharges in 5 minutes of 400J sinusoidal energy delivered into 50 ohms when all wires are shorted and foil surrounds the cable 2 4 cc/hr or 20 40cc/hr, depending on model, with an infusion pressure (difference) of 200mmHg. Min 50cc/min using a microdrip administration set with 60 inch of IV tubing with an infusion pressure (difference) of 200mmHg. Max Length: 8.4cm (Inc zero stopcock and male luer fitting); Max Width: 3.2cm; Max Height: 3cm (Inc Easy- Vent Deadender on Zero stopcock). Length of Transducer electric cable: 34.5cm
37 ritical Disposable Care catalogue 2005 Pressure 16/2/05 3:32 Transducer pm Page 15 BD DTX Plus TM Disposable Pressure Transducers Argon offers a wide range of disposable transducers and transducer sets BD offers a wide range of disposable and reusable transducers. BD s experience is based on decades of research and development reaching back to the first practical blood pressure transducer introduced Model by Gould-Statham. Pressure Transducer Sets Argon DTX Plus TM Disposable Pressure Transducers Content (Units) Product ModelDT-XX Disposable transducer with Critiflex integral 10/ flush device and stopcock Contents (3cc/hr (Units) nominal flow rate) Item Number 10/ DT-NN Disposable transducer for neonatal/paediatric uses, used in conjunction with a mechanical infusion pump (max. 30cc/hr flow rate) 10/ DT-XX Disposable transducer with Critiflex integral 10/ DT-XO flush Disposable device and stopcock transducers (3cc/hr with nominal integral flow flush rate) device without stopcock (3cc/hr nominal flow rate) 10/ DT-NN Disposable transducer for neonatal/paediatric uses. 10/ TNF-R Disposable transducer without integral flush device or stopcock, suitable for cardiology/neurology applications Used in conjunction with a mechanical infusion pump 10/ (max. 30cc/hr flow rate) DT-XO Disposable transducers with integral flush 10/ device without stopcock (3cc/hr nominal flow rate) TNF-R Disposable transducer without integral flush device 10/ or stopcock. Suitable for cardiology/neurology applications Class lla according to the European Medical Devices Class IIa according Directive to European 93/42/EEC Medical as Devices amended Directive by Directive 2007/47/EC Shelf life: 5 years 5 years 93/42/EEC Sterilisation method: Ethylene oxide Shelf life: BD DTX Plus TM Disposable Pressure Transducer Sets Designed for ease of use and minimal wavelength distortion Stand alone Administration Sets Haemodynamic monitoring information is used to manage the care of critically ill patients. It is therefore essential that you are confident about the accuracy of the information that you are using. Fluid filled pressure monitoring systems will cause some distortion to the pressure Product waveform. Up to 40% distortion has been shown in some cases. 1 Content (Units) Accuracy in pressure monitoring isn t just dependent on the transducer, it s dependent on all the components in the pressure monitoring system; Single catheter, administration pressure set tubing, with 15µ monitor filter, angled filter cannula and stopcocks. and roller clamp It has (red) been shown 2 that in order to know the accuracy of your system, you 5/ need to consider the performance of the total chain where all the components are linked together. Double administration set with 15µ filter, angled cannula and roller clamps (red/blue) As a manufacturer we believe we have a responsibility to provide you with information PRESSURE OUT 5/ PRESSURE IN about Triple the administration accuracy of set the with 15µ whole filter, angled monitoring cannula system, and roller not clamps just (red/blue/white) the transducer. 5/ Therefore, BD has selected a range of standard BD DTX Plus TM TESTED SET sets which are Gabarith ACCEPTED tested. 2 AS WITHIN GABARITH GABARITH WINDOW The BD Gabarith TM WINDOW OF test remains the only scientific technique that provides information TOLERANCE about CE the marked dynamic response performance of the total pressure monitoring system TESTED SET DISCARDED 1 AS OUTSIDE (total chain). DYNAMIC GABARITH RESPONSE The Class BD Gabarith lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC WINDOW test assesses the system against pre-set windows of error (2%, 5% Hz and 10% waveform distortion). For example: If the dynamic response of a pressure chain falls Shelf within the life: 10% 5 years Example of Radial Artery pressure Gabarith window then we know the pressure waveform will not be distorted 10% error Gabarith window by more than 10%. Sterilisation method: (for adult kit) Ethylene Oxide Windows of tolerance are based on catheter tip sensor results (the gold standard) using real patient data. Every box of BD DTX Plus pressure monitoring sets is stamped with the BD Gabarith TM symbol. This shows that the set has passed the BD Gabarith TM test and has a known level of accuracy. The BD Gabarith TM test exceeds the demands of the AAMI standard (Association for the Advancement of Medical Instrumentation). References: (1) Anesthesiology 53: , 1980; British Journal of Anaesthesia 1987, 59, ; European Academy of Anaesthesiology - Strasbourg Aug/Sep 1997 (Bender HJ, Billiet E et al). (2) Billiet E, Colardyn F. (1998) Pressure Measurement Evaluation and Accuracy: The Gabarith Test. Intensive Care Medicine 24: (3) Assuming that the set has been set up and zeroed in accordance with manufacturing instructions 15
38 Disposable Pressure Transducer ical Care catalogue /2/05 3:32 pm Page 16 Pressure Transducer Sets Disposable Transducer Sets for the Invasive Monitoring of Haemodynamic Pressure BD Gabarith TM Disposable Argon Gabarith Transducer Sets TM Disposable Transducers Sets Disposable Transducer Sets for the Invasive Monitoring of Haemodynamic Pressure Number of Flush/Flow rate Total Pressure line(s) Additional Item Disposable No. of disposable (cc/hr) Transducers transducers Flush/Flow Pressure line Rate length cc/hr (cm) Total colour Pressure Line Length Pressure Information Line(s) Colour ContentsAdditional Number (Units) Information Content (Units) Product Clear with R.O.S.E. 5/ cm Clear With Argon R.O.S.E. 5/ Clear 5/ Red 150cm Clear 5/ / Blue with R.O.S.E. 5/ Blue 150cm Red 5/ / Yellow 150cm Add-on set to set Blue no , -38, -55 5/50 With Argon R.O.S.E / Red with R.O.S.E. 5/ Red 150cm Blue 5/ / Clear Velcro strap for arm mount 5/ cm Yellow Add-on set to set no , -38, -55 5/ Blue with Multiflo 5-way 5/ Clear 175cm w/ non-shunting stopcock Red & extension set 5/25 With Argon R.O.S.E / small bore Clear For use with infusion pump 5/ small bore 175cm Clear Red For use with infusion pump 5/ / /150 Red/Blue 25cm with R.O.S.E. Clear on blue line Velcro 5/25strap for arm mount 5/ /150 Red/Blue 5/ /150 Red/Blue 150cm with 3rd IV line Blue for add-on set 5/25 With Multiflo TM 5-way / /150 Blue/Yellow 5/ cm Clear With non-shunting stopcock and extension set 5/ /150/150 Red/Blue/Yellow 5/ cm small bore Clear For use with infusion pump 5/ Validation 1by unique Gabarith 30 accuracy test. 35cm small bore BD Connecta Clear TM Plus sampling and zeroing For use stopcocks with infusion with pump 5/ on/off snap for confirmation of stopcock positioning. A range of 2 Single, Double and 3Triple Disposable Transducer 150/150cm Red/Blue With Argon R.O.S.E. on blue line 5/ Sets. Designed straight fluid pathway minimises the risk of bubble /150cm Red/Blue 5/ entrapment and subsequent damping of signal. Adult and Paediatric options /150cm Red/Blue With 3rd IV line for add-on set 5/ Robust monitor connection prevents water penetration and BD Safedraw TM, closed loop arterial blood sampling system /150cm offers back Blue/Yellow pressure calibration facility. 5/ available. (Please refer to next section) /150/150cm Unique Red/Blue/Yellow Easy Vent zeroing deadender minimises risk of 5/ R.O.S.E (Resonance OverShoot Eliminator) included in touch contamination. selected sets. Wide range of transducer set configurations covering Individually packed, sterile, non-pyrogenic and latex-free. Validation by unique Argon Gabarith TM accuracy test neonatal to adult pressure Robust monitoring monitor requirements. connection prevents water penetration and offers back Adult A range pressure of Single, sets include Double rotating and male Triple luer Disposable for easy and Transducer Sets pressure calibration facility trouble-free connection onto the catheter. Sterilisation method: Adult and Paediatric options. Unique Argon EasyVent TM zeroing deadender minimises risk of touch Ethylene oxide contamination How Argon BD Gabarith Safedraw TM sets and can Safedraw-P benefit you TM closed loop arterial blood sampling system options available (please refer to next section) Shelf life: Wide range of transducer set configurations covering neonatal to adult Unique Gabarith testing of sets, using total 5 years pressure monitoring requirements haemodynamic Argon R.O.S.E. chain (Resonance concept, offers OverShoot the opportunity Eliminator) for included in selected sets improved haemodynamic accuracy 1. Class IIa according to European Latex Medical free Devices Directive Individually packed, sterile, non-pyrogenic and latex-free93/42/eec Adult pressure sets include rotating male luer for easy and trouble-free connection onto the catheter Class lla according to the European Medical Devices 1 Billiet E., Colardyn F. Pressure Measurement Evaluation & Accuracy Validation: The Gabarith Test. Intensive Care Medicine (1998) 24: How Argon Gabarith TM Sets can benefit you Unique Argon Gabarith TM testing of sets, using total haemodynamic chain concept, offers the opportunity for improved haemodynamic accuracy 1. Argon sampling and zeroing stopcocks with on/off snap for confirmation of stopcock positioning Designed straight fluid pathway minimises the risk of bubble entrapment and subsequent damping of signal Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 5 years 1 Billiet E., Colardyn F. Pressure Measurement Evaluation & Accuracy Validation: The Gabarith Test. Intensive Care Medicine (1998) 24:
39 Critical Care Systems Pressure Transducer Sets Argon Safedraw TM Safe Arterial Sampling Disposable Transducer Sets Argon Safedraw TM safe arterial blood sampling systems significantly reduce unnecessary blood discard and blood spillage, thereby reducing the risk of iatrogenic anaemia and cross contamination to patients and staff. The system s easy-to-use, self-sealing, silicone septum facilitates easier blood sampling and superior clinical samples, thereby achieving more reliable laboratory values. The Safedraw TM core-resistant septum helps to minimise exposure to pathogens by preventing non-sterile contact with the fluid path whilst enabling the taking of multiple samples. Unique Argon Gabarith TM testing of Safedraw TM sets, using total haemodynamic chain concept, offers the opportunity for improved haemodynamic accuracy. Available in Single, Double, Triple and Argon Flexi Disposable Transducer configurations, with Adult and Paediatric options, Safedraw TM systems are individually packed, sterile, non-pyrogenic and latex-free. No. of Disposable Transducers Flush/ Flow Rate (cc/hr) Total Pressure Line Length (cm) Pressure Line(s) Colour Additional Information Safedraw Syringe Volume (cc) Contents (Units) Product cm (125/30) Clear Single Admin Set. Single Transducer Set with Integrated Safedraw TM Septum (Red) 2cc 5/ A: 155cm (125/30) V: 150cm (125/25) A: Clear V: Blue Bifurcated Admin Set. Double Transducer Set with Integrated Safedraw TM Septum (Red) and R.O.S.E on Venous Line 2cc 5/ A: 155cm (125/30) V: 150cm (125/25) A: Clear V: Blue Bifurcated Admin Set. Double Transducer Set with Integrated Safedraw TM Septum (Red) 2cc 5/ A: 155cm (125/30) V: 150cm (125/25) A: Clear V: Blue Trifurcated Admin Set. Double Transducer Set with Integrated Safedraw TM Septum (Red) 2cc 5/ A: 155cm (125/30)V: 150cm (125/25) PA: 150cm (125/25) A: Clear V: Blue PA: Yellow Trifurcated Admin Set. Triple Transducer Set with Integrated Safedraw TM Septum (Red) 2cc 5/ cm (160/30) Red/Clear cm (75/85/30) Red/Clear cm (160/30) Red/Clear 1 30 (Paed Set) 135cm (125/10) Clear 1 3 (Paed Set) 135cm (125/10) Clear 1 3 (Paed Set) 29cm (22/7) Clear Single Admin Set. Single 'Flexi' Transducer Set with Integrated Safedraw TM Septum (Red) Single Admin Set. Single 'Flexi' Transducer Set with 2 x Integrated Safedraw TM Septums (Red) No Admin Set. Single 'Flexi' Add-On Transducer Set with Integrated Safedraw TM Septum (Red) Single Paediatric Transducer Set with Integrated Safedraw TM Septum (Red) For use with Infusion Pump Single Paediatric Transducer Set with Integrated Safedraw TM Septum (Red) For use with Infusion Pump Single Paediatric Set with Integrated Safedraw TM Septum (Red) For use with Infusion Pump 2.5cc 5/ cc 5/ cc 5/ cc 5/ cc 5/ cc 5/ Argon Safedraw TM Accessories Product Model Content (Units) Product Safedraw TM Vacutainer Transfer Device TA-STV 25/ Safedraw TM Luer-Lok Safe-Needle TA-BPN 50/ Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 5 years
40 Critical Care Systems Pressure Transducer Sets Argon Safedraw-P TM Safe Arterial Sampling Disposable Transducer Sets Argon Safedraw-P TM arterial blood sampling systems are a unique range of invasive pressure monitoring sets designed for closed loop, safe arterial blood sampling procedures. Whole blood samples are collected via direct luer-slip access into the unique Safedraw-P TM split-septum blood sampling port, thereby negating the need for blood sampling adapters. The Safedraw-P TM blood sampling port is either integrated directly into the tubing, or as an integral part of the special three-way sampling stopcock. Safedraw-P TM safe arterial blood sampling systems significantly reduce unnecessary blood discard and blood spillage, thereby reducing the risk of iatrogenic anaemia and cross contamination to patients and staff. The system s direct luer-slip access design facilitates easier blood sampling and superior clinical samples, thereby achieving more reliable laboratory values. Unique Argon Gabarith TM testing of Safedraw-P TM sets, using total haemodynamic chain concept, offers the opportunity for improved haemodynamic accuracy. Available in Single, Double, Triple and Argon Flexi Disposable Transducer configurations, with Adult and Paediatric options, Safedraw-P TM systems are individually packed, sterile, non-pyrogenic and latex-free. See product table on next page. Argon Safedraw-P TM Accessories Product Shelf Life Content (Units) Product Safedraw-P TM Luer-lock Adapter System 5 Years 50/ Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 2 years
41 Critical Care Systems Pressure Transducer Sets Argon Safedraw-P TM Safe Arterial Sampling Disposable Transducer Sets No. of Disposable Transducers Flush/ Flow Rate (cc/hr) Total Pressure Line Length (cm) Pressure Line(s) Colour Additional Information Safedraw Syringe Volume (cc) Septum Model Contents (Units) Product cm (153/30) Clear cm (183/30) Red/Clear cm (133/90) Red/Clear cm (63/15) Red/Clear Single Admin Set. Single Transducer Set with Integrated Safedraw-P TM Septum (Red) Single Admin Set. Single Transducer Set with Integrated Safedraw-P TM Septum (Red) Single Admin Set. Single Transducer Set with Integrated Safedraw-P TM Septum (Red) Single Admin Set. Single Transducer Set with Integrated Safedraw-P TM Septum (Red) with Velcro Strap for Arm mounting 2cc 1 x Inline 5/ cc 1 x Inline 5/ cc 1 x Inline 5/ cc 1 x Inline 5/ A: 213cm (183/30) V: 150 A: Red/Clear V: Blue Single Admin Set. Single Transducer Set with non-shunting stopcock and Integrated Safedraw-P TM Septum (Red) (with Separately Packaged 150cm Blue pressure line) 2.5cc 1 x Inline 5/ A: 183cm (153/30) V: 125 A: Red/Clear V: Blue Single Admin Set. Single Transducer Set with R.O.S.E., non-shunting stopcock, and Integrated Safedraw-P TM Septum (Red) (with Separately Packaged 125cm Blue pressure line) 2cc 1 x Inline 5/ A: 193cm (163/30) V: 150 A: Red/Clear V: Blue Single Admin Set. Single Transducer Set with non-shunting stopcock (with 150cm Blue pressure line) and Integrated Safedraw-P TM Septum (Red) 2.5cc 1 x Inline 5/ A: 183cm (153/30) V: 150cm (125/25) A: Clear V: Blue Bifurcated Admin Set. Double Transducer Set with Integrated Safedraw-P TM Septum (Red) 2cc 1 x Inline 5/ A: 213cm (183/30) V: 186cm (183/3) A: Red/Clear V: Blue/Clear Bifurcated Admin Set. Double Transducer Set with Integrated Safedraw-P TM Septum (Red) and Integrated Safedraw-P TM Stopcock Septum (Blue) 2.5cc 1 x Inline (Red) 1 x Stopcock (Blue) 5/ A: 223cm (133/90) V: 216cm (183/33) A: Red/Clear V: Blue/Clear Bifurcated Admin Set. Double Transducer Set with Integrated Safedraw-P TM Septum (Red) and Integrated Safedraw-P TM Stopcock Septum (Blue) 3cc 1 x Inline (Red) 1 x Stopcock (Blue) 5/ A: 223cm (133/90) V: 90cm A: Red/Clear V: Blue Trifurcated Admin Set. Double Transducer Set with Integrated Safedraw-P TM Septum (Red) and Integrated Stopcock (Blue) 3cc 1 x Inline (Red) 5/ A: 223cm (133/90) V: 211cm (183/28) A: Red/Clear V: Blue/Clear Trifurcated Admin Set. Double Transducer Set with Integrated Safedraw-P TM Septum (Red) and Integrated Safedraw-P TM Stopcock Septum (Blue) 3.5cc 1 x Inline (Red) 1 x Stopcock (Blue) 5/ A: 233cm (143/90) V: 205cm (180/25) A: Red/Clear V: Blue/Clear Trifurcated Admin Set. Double Transducer Set with Integrated Safedraw-P TM Septum (Red) and 2 x Sampling Stopcocks (Blue) 3cc 1 x Inline (Red) 5/ A: 213cm (183/30) V: 126cm (123/3) PA: 120cm A: Red/Clear V: Blue/Clear PA: Yellow Trifurcated Admin Set. Triple Transducer Set with Integrated Safedraw-P TM Septum (Red) and Integrated Safedraw-P TM Stopcock Septum (Blue) 3cc 1 x Inline (Red) 1 x Stopcock (Blue) 5/ cm (163/30) Red/Clear cm (163/30) Red/Clear cm (183/30) Red/Clear cm (53/120/30) Red/Clear cm (73/90/30) Red/Clear 1 3 (Paed Set) 143cm (128/15) Clear 1 3 (Paed Set) 158cm (153/5) Clear 1 30 (Paed Set) 158cm (153/5) Clear Single Admin Set. Single 'Flexi' Transducer Set with non-shunting stopcock and Integrated Safedraw-P TM Septum (Red) Single Admin Set. Single 'Flexi' Transducer Set with Integrated Safedraw-P TM Stopcock Septum (Red) Single Admin Set. Single 'Flexi' Transducer Set with Integrated Safedraw-P TM Septum (Red) Single Admin Set. Single 'Flexi' Transducer Set with 2 x Integrated Safedraw-P TM Septums (Red) Single Admin Set. Single 'Flexi' Transducer Set with 2 x Integrated Safedraw-P TM Stopcock Septums (Red) Single Paediatric Transducer Set with Integrated Safedraw-P TM Septum (Red) For use with Infusion Pump Single Paediatric Transducer Set with Integrated Safedraw-P TM Septum (Red) For use with Infusion Pump Single Paediatric Transducer Set with Integrated Safedraw-P TM Septum (Red) For use with Infusion Pump 2.5cc 1 x Inline 5/ cc 1 x Stopcock 5/ cc 1 x Inline 5/ cc 2 x Inline 5/ cc 2 x Stopcock 5/ cc 1 x Inline 5/ cc 1 x Inline 5/ cc 1 x Inline 5/
42 Critical Care Systems Pressure Transducer Sets Argon DTX Plus TM Paediatric and Neonatal Disposable Transducer Sets Argon DTX Plus TM Paediatric and Neonatal Transducer Systems are a range of Standard and Closed loop Safedraw TM and Safedraw-P TM safe arterial blood sampling invasive pressure monitoring sets specifically designed with the Paediatric and Neonatal patient in mind. Whole blood samples are collected in the closed-loop Safedraw TM and Safedraw-P TM sets either via the Safedraw TM self-sealing silicone septum or via direct luer-slip access into the unique Safedraw-P TM split-septum blood sampling port. Safedraw TM and Safedraw-P TM safe arterial blood sampling systems significantly reduce unnecessary blood discard and facilitate the safe return of diluted blood back to the infant, thereby safely conserving blood volume whilst reducing the risk of iatrogenic anaemia and cross contamination. The system s design facilitates easier blood sampling and superior clinical samples, thereby achieving more reliable laboratory values. Unique Argon Gabarith TM testing of these Paediatric and Neonatal sets, using total haemodynamic chain concept, offers the opportunity for improved haemodynamic accuracy. Configured for use with an Infusion Pump, Argon DTX Plus TM Paediatric and Neonatal Transducer Systems are individually packed, sterile, non-pyrogenic and latex-free. No. of Disposable Transducers Flush/ Flow Rate (cc/hr) Total Pressure Line Length (cm) Pressure Line(s) Colour Additional Information Safedraw Syringe Volume (cc) Septum Model Contents (Units) Product 1 30 (Paed Set) 160cm (150/10) Clear 1 30 (Paed Set) 35cm (25/10) Clear Single Paediatric Transducer Set For use with Infusion Pump Single Paediatric Transducer Set For use with Infusion Pump N/A N/A 5/ N/A N/A 5/ (Paed Set) 135cm (125/10) Clear Single Paediatric Transducer Set with Integrated Safedraw TM Septum (Red) For use with Infusion Pump 1cc Safedraw TM 1 x Inline 5/ (Paed Set) 135cm (125/10) Clear Single Paediatric Transducer Set with Integrated Safedraw TM Septum (Red) For use with Infusion Pump 2.5cc Safedraw TM 1 x Inline 5/ (Paed Set) 29cm (22/7) Clear Single Paediatric Set with Integrated Safedraw TM Septum (Red) For use with Infusion Pump 0.5cc Safedraw TM 1 x Inline 5/ (Paed Set) 143cm (128/15) Clear Single Paediatric Transducer Set with Integrated Safedraw-P TM Septum (Red) For use with Infusion Pump 2.5cc Safedraw-P TM 1 x Inline 5/ (Paed Set) 158cm (153/5) Clear Single Paediatric Transducer Set with Integrated Safedraw-P TM Septum (Red) For use with Infusion Pump 2cc Safedraw-P TM 1 x Inline 5/ (Paed Set) 158cm (153/5) Clear Single Paediatric Transducer Set with Integrated Safedraw-P TM Septum (Red) For use with Infusion Pump 2cc Safedraw-P TM 1 x Inline 5/ Argon Safedraw TM and Safedraw-P TM Accessories Product Shelf life Content (Units) Product Safedraw-P TM Luer-lock Adapter System 5 Years 50/ Safedraw TM Vacutainer Transfer Device (TA-STV) 5 Years 25/ Safedraw TM Luer-Lok Safe-Needle (TA-BPN) 5 Years 50/ & Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 5 years (for Standard and Safedraw TM sets) 2 years (for Safedraw-P TM sets)
43 Critical Care Systems Pressure Transducer Sets Argon DTX Plus TM Flexi Disposable Transducer Sets Argon DTX Plus TM Flexi Transducer Systems are a range of invasive pressure monitoring sets designed to improve Procurement stocking efficiency through facilitating appropriate set configuration selection whilst minimising unused set component wastage. In the Flexi configuration the Arterial disposable transducer system is used as the master line. When clinically required, additional lines are connected to this master line in a cascade. This is achieved via an additional stopcock positioned on the administration set side of the transducer, thereby having no impact on dynamic response. This innovative Flexi solution, offering the adaptability of single, or multiple transducer set configurations, facilitates set selection, set-up time whilst minimising storage costs. Available in Standard set format, Safedraw TM or Safedraw-P TM Closed-loop, arterial blood sampling formats, Argon DTX Plus TM Flexi Transducer Systems are individually packed, sterile, non-pyrogenic and latex-free. No. of Disposable Transducers Flush/ Flow Rate (cc/hr) Total Pressure Line Length (cm) Pressure Line(s) Colour Additional Information Safedraw Syringe Volume (cc) Septum Model Contents (Units) Product cm (150/25) Red Single Admin Set. Single 'Flexi' Arterial Transducer Set N/A N/A 5/ cm (160/15) Blue No Admin Set. Single 'Flexi' Add-On Venous Transducer Set N/A N/A 5/ cm (175) Yellow No Admin Set. Single 'Flexi' Add-On PA Transducer Set N/A N/A 5/ cm (160/15)) Clear No Admin Set. Single 'Flexi' Add-On Universal Transducer Set N/A N/A 5/ cm (160/15) Blue Single Admin Set. Single 'Flexi' Venous Transducer Set N/A N/A 5/ cm (160/30) Red/Clear Single Admin Set. Single 'Flexi' Transducer Set with Integrated Safedraw TM Septum (Red) 2.5cc Safedraw TM 1 x In-Line 5/ cm (75/85/30) Red/Clear Single Admin Set. Single 'Flexi' Transducer Set with 2 x Integrated Safedraw TM Septums (Red) 2.5cc Safedraw TM 2 x In-Line 5/ cm (160/30) Red/Clear No Admin Set. Single 'Flexi' Add-On Transducer Set with Integrated Safedraw TM Septum (Red) 2.5cc Safedraw TM 1 x In-Line 5/ cm (163/30) Red/Clear Single Admin Set. Single 'Flexi' Transducer Set with nonshunting stopcock and Integrated Safedraw-P TM Septum (Red) 2.5cc Safedraw-P TM 1 x In-Line 5/ cm (163/30) Red/Clear Single Admin Set. Single 'Flexi' Transducer Set with Integrated Safedraw-P TM Stopcock Septum (Red) 3cc Safedraw-P TM 1 x Stopcock 5/ cm (183/30) Red/Clear Single Admin Set. Single 'Flexi' Transducer Set with Integrated Safedraw-P TM Septum (Red) 2.5cc Safedraw-P TM 1 x In-Line 5/ cm (53/120/30) Red/Clear Single Admin Set. Single 'Flexi' Transducer Set with 2 x Integrated Safedraw-P TM Septums (Red) 2.5cc Safedraw-P TM 2 x In-Line 5/ cm (73/90/30) Red/Clear Single Admin Set. Single 'Flexi' Transducer Set with 2 x Integrated Safedraw-P TM Stopcock Septums (Red) 3cc Safedraw-P TM 2 x Stopcock 5/ Argon Flexi Safedraw TM and Safedraw-P TM Accessories Product Shelf life Content (Units) Product Safedraw-P TM Luer-lock Adapter System 5 Years 50/ Safedraw TM Vacutainer Transfer Device (TA-STV) 5 Years 25/ Safedraw TM Luer-Lok Safe-Needle (TA-BPN) 5 Years 50/ & Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 5 years (for Standard and Safedraw TM sets) 2 years (for Safedraw-P TM sets)
44 Critical Care Systems Pressure Transducer Sets Argon RT2000 Reusable Transducer and Disposable Domes and Dome systems Argon RT2000 Reusable Transducer and Disposable Domes and Dome Systems are engineered to improve cost efficiencies by reducing disposal costs and biological wastage generation whilst maintaining pressure waveform accuracy and reliability. With the Argon RT2000 system only the sterile disposable dome components are discarded after each patient use whilst the reusable RT2000 transducer is retained ready for the next patient s use. This enables the cost per patient set-up to be lower than fully disposable transducer systems and minimises environmental impact by reducing the volume of hazardous waste generated per patient. The one-handed snap-on dry coupling system for engagement of the disposable sterile dome set with the Argon RT2000 reusable transducer system is simple and quick to perform, thereby minimising initial set-up time. The straight and visible fluid pathway enables the disposable dome to fill, bubble-free with minimal effort. The integrated flush device and venting EasyVent zeroing stopcock provide quick, effective fluid control. Argon RT2000 systems are available in Flexi format and with the Safedraw TM and Safedraw-P TM safe arterial blood sampling systems. These systems are designed to significantly reduce unnecessary blood discard and blood spillage, thereby reducing the risk of iatrogenic anaemia and cross contamination to patients and staff. Whole blood samples are collected in the closed-loop Safedraw TM and Safedraw-P TM sets either via the Safedraw TM self-sealing silicone septum or via direct luer-slip access into the unique Safedraw-P TM split-septum blood sampling port. The closed-loop system design facilitates easier blood sampling and superior clinical samples, thereby achieving more reliable laboratory values. Available in Argon Standard and Flexi Disposable Dome configurations, with Adult Safedraw TM and Safedraw-P TM options, Argon RT2000 Dome systems are individually packed, sterile, non-pyrogenic and latex-free. See product table on next page. Argon RT2000 Reusable Transducer Specifications Detail Operating pressure: Overpressure withstand Nominal sensitivity (gain): Linearity: Hysteresis: Unbalance (zero balance): Argon RT2000 Transducer specifications -30 to 300 mmhg 5,170 mmhg 5 µv/v/mmhg ±1% over 0-50 mmhg ±3% over mmhg +40 mmhg Thermal coefficient of sensitivity (typical): ±1% / ºC Thermal coefficient of zero (typical): ±3% mmhg / ºC Leakage: Defibrillator withstand: Maximum Excitation Voltage: <5µA at 220V 50Hz Withstand five repeated discharges in 5 minutes of 400J sinusoidal energy delivered into 50 ohms when all transducer wires are shorted and saline is in fluid column 10V DC or AC
45 Critical Care Systems Pressure Transducer Sets Argon RT2000 Reusable Transducer and Disposable Domes and Dome systems No. of Disposable Domes Flush/ Flow Rate (cc/hr) Total Pressure Line Length (cm) Pressure Line(s) Colour Additional Information Safedraw Syringe Volume (cc) Model Contents (Units) Product N/A N/A N/A N/A Argon RT2000 reusable pressure transducer N/A RT / N/A N/A 1 N/A N/A N/A cm (150/25) Clear cm (150/25) Red RT2000 Disposable dome with integral flow/flush device (3cc/hr nominal flow rate) and Zeroing Stopcock RT2000 Disposable dome without integral flow/flush device or Zeroing Stopcock Single Admin Set. Single RT2000 'Universal' Dome Set Single Admin Set. Single 'Flexi' RT2000 Arterial Dome Set with non-shunting stopcock N/A DD / N/A DD / N/A N/A 5/ N/A N/A 5/ cm (150/25) A: Red V: Blue Single Admin Set. Single 'Flexi' RT2000 Arterial Dome Set with non-shunting stopcock (with Separately Packaged 150cm Blue pressure line) N/A N/A 5/ cm (160/15) Blue cm (175) Yellow No Admin Set. Single 'Flexi' RT2000 Add-On Venous Dome Set No Admin Set. Single 'Flexi' RT2000 Add-On PA Dome Set N/A N/A 5/ N/A N/A 5/ cm (163/30) Red/Clear Single Admin Set. Single 'Flexi' RT2000 Arterial Dome Set with non-shunting stopcock and Integrated Safedraw-P TM Septum (Red) 2.5cc Safedraw-P TM 1 x Inline 5/ A: 180cm (150/30) V: 150 A: Red/Clear V: Blue Single Admin Set. Single RT2000 Arterial Dome Set with non-shunting stopcock (with 150cm Blue pressure line) and Integrated Safedraw-P TM Septum (Red) 2.5cc Safedraw-P TM 1 x Inline 5/ Argon RT2000 Safedraw TM and Safedraw-P TM Accessories Product Shelf life Content (Units) Product Safedraw-P TM Luer-lock Adapter System 5 Years 50/ Safedraw TM Vacutainer Transfer Device (TA-STV) 5 Years 25/ Safedraw TM Luer-Lok Safe-Needle (TA-BPN) 5 Years 50/ Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 5 years (for Standard and Safedraw TM sets) 2 years (for Safedraw-P TM sets) Note: RT2000 Reusable Transducer Unit is provided non-sterile and with one year s manufacturer s warranty
46 Critical Care Systems Pressure Transducer Sets Catheter Lab Set Argon Cardiac Catheterisation Laboratory DTX Plus TM Transducer Set Configurations Contrast Saver Set Argon Cardiac Catheterisation Laboratory DTX Plus TM Transducer Set Configurations With a choice of high quality pressure monitoring and fluid management components to choose from, Argon s range of Cardiac Cath Lab Transducer sets are designed to meet the challenges and requirements of your cardiac catheterisation laboratory. Where accurate pressure readings are vital, Argon s long history in pressure monitoring and transducer development, dating back to the first reusable transducer in 1946, has resulted in the Argon DTX Plus TM transducer set options. With ease of priming and de-bubbling, with standard and 106cm (42 ) cable option and a choice of flush and no-flush versions, the Argon DTX Plus TM transducer sets facilitate accurate pressure monitoring within the Cath Lab environment. Argon high pressure manifolds are supplied with a choice of Open or Finger grip (Block) design, 2, 3 or 4 ports, and having either Left or Right rotating adapter to best meet specific procedural needs and physician preferences. Manifolds designed with tight tolerances, low torque and smooth port rotation and manifold Distal Rotating Adapter facilitates easy catheter manipulation. Choice of Open or Block body design and clear polycarbonate body for easy bubble visualisation, the manifolds construction will withstand injections and are rated at 500 psi. Available in clear, semi-rigid PVC and Flexible Braided Polyurethane with or without Rotating Adapter, Argon High Pressure Injection Lines are designed to provide optimal flexibility, easy debubbling and secure connections and are rated up to 1200 psi. Argon Control Syringes are available with choice of Thumb Ring or Palm Pad design, Finger Ring vs Finger Grip, and 10cc vs 12cc volume options to best suit most Clinical Needs and hand sizes. Control syringe low friction plunger provides for a smooth injection, bold volume markings facilitate accurate volume injections, whilst the clear polycarbonate body provides a sturdy syringe able to withstand any hand pressure whilst facilitating for easy bubble visualisation. 10cc or 12cc volume options for larger handed use. Choice of syringe Palm Pad designs, including soft touch options, allows for full force palm injections and thumb ring design facilitates aspirations and injections whilst choice of finger grip or ring style to meet most clinical needs. Contrast Saver Administration set options available to reduce Contrast wastage and reduce risk of air entering the system. Argo-Bagz TM 1,500ml PVC bag Waste Management System options, High Pressure stopcocks (850 psi rated) and other componentry also available to enhance kit functionality. Argon Cardiac Catheterisation Laboratory DTX Plus TM Transducer Set Configurations are available as Off-the-shelf options. (Other Cath Lab configurations and Custom kit configuration options are available on request.) See product table on next page.
47 Critical Care Systems Pressure Transducer Sets Catheter Lab Set Argon Cardiac Catheterisation Laboratory DTX Plus TM Transducer Set Configurations Contrast Saver Set Disposable Transducer Model Flush/ Flow Rate (cc/hr) Manifold Pressure Line(s) Colour Additional Information Check Valves Contrast Syringe Contents (Units) Product DTX Plus TM TNF-R with 106cm transducer cable No Flush 3-way, 360 'off-directed', right orientated, block body, Rotating Adapter 25cm High Pressure braided Argon Cath Lab set with DTX Plus TM TNF-R transducer, 3-way 'off-directed' right orientated manifold with 25cm High pressure braided tubing, administration set (15 micron filter), Dual Check Valve and 12ml Contrast Syringe. (For use with Contrast Saver set P/N: ) 1 x Dual Check Valve 12ml with thumb/ finger rings and rotating adapter 5/ N/A N/A N/A N/A Argon Contrast Saver Kit with 30ml burette and white stopcock. (For use with DTX Plus TM Manifold Cath Lab Kits) N/A N/A 5/ DTX Plus TM DT-XX 3cc/hr 2-way 'on-directed', right orientated, block body, Rotating Adapter 75cm Clear Argon Cath Lab set with DTX Plus TM DT-XX pressure transducer, 75cm Clear pressure line, 2-way 'on-directed' right orientated manifold with Contrast administration set (200 micron filter), 12ml Contrast Syringe and administration set (15 micron filter). N/A 12ml with thumb/ finger rings and rotating adapter 5/ DTX Plus TM DT-XX 3cc/hr N/A 150cm Red Argon Cath Lab set with DTX Plus TM DT-XX pressure transducer with administration set (15 micron filter), 150cm Red pressure line, stopcock and High Pressure Rotating Adapter. (FOR PAEDIATRIC CATHETERISATION PROCEDURES) N/A N/A 5/ DTX Plus TM TNF-R No Flush 2-way 360 'off-directed', right orientated, block body, Rotating Adapter 150cm Clear Argon Cath Lab set with Dual Check Valve, 2-way 'off-directed' right orientated manifold with 2 x Contrast administration sets (200 micron filter), 150cm Clear pressure tubing and 10ml Contrast Syringe. Separately packaged DTX Plus TM TNF-R transducer with tap and ROSE (Resonance OverShoot Device). 1 x Dual Check Valve 10ml with thumb ring/finger grips and 0.5ml 'stop' ring 5/ DTX Plus TM DT-XX 3cc/hr N/A 25cm, 30cm and 75cm Clear Argon Cath Lab set with DTX Plus TM DT-XX pressure transducer with administration set (15 micron filter), 75cm Clear pressure line, High Presssure stopcock with 30cm Clear pressure line and 25cm Clear pressure line and High Pressure Rotating Adapter N/A N/A 5/ DTX Plus TM DT-XX 3cc/hr 2-way 'on-directed', right orientated, block body, Rotating Adapter 150cm Clear Argon Cath Lab set with DTX Plus TM DT-XX pressure transducer with administration set (15 micron filter), 150cm Clear pressure line and 2-way 'on-directed' right orientated manifold. N/A N/A 5/ DTX Plus TM TNF-R No Flush 3-way 'on-directed', right orientated, block body, Rotating Adapter 130cm Clear, 120cm High Pressure Argon Cath Lab set with DTX Plus TM TNF-R transducer with tap, 130cm Clear pressure tubing, 3-way 'ondirected' right orientated manifold with administration set (15 micron filter) with tap, 120cm High Pressure tubing and 12ml Contrast Syringe. (For use with Contrast Saver set P/N: ) N/A 12ml with thumb/ finger rings and rotating adapter 5/ DTX Plus TM TNF-R No Flush N/A 130cm Clear Argon Cath Lab set with DTX Plus TM TNF-R pressure transducer with 3 way stopcock, 130cm Clear pressure line, 2 x 3 way stopcocks and administration set (15 micron filter). N/A N/A 5/ DTX Plus TM DT-XX 3cc/hr N/A 100cm Clear Argon Cath Lab set with 10ml Contrast Syringe. Separately packaged DTX Plus TM DT-XX pressure transducer with administration set (15 micron filter), 100cm Clear pressure line, 3 way stopcock with High Pressure Rotator Adapter and Dual Check Valve with contrast administration set (15 micron filter). 1 x Dual Check Valve 10ml with thumb ring/finger grips 5/ Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: Dependent on kit contents
48 Lines and Pressure Accessories Argon Pressure Lines & Pressure Accessories Male/Female or Male/Male Line Connection Tubing Length Line Colour Coding Content (Units) Priming Volume (cm 3 ) Tube Diameter Inner (mm) Outer (mm) Product ARGON PRESSURE LINES (PVC) M/F 25cm Clear 25/ (± 0.076) (± 0.051) M/F 100cm Clear 25/ (± 0.076) (± 0.051) M/F 150cm Clear 25/ (± 0.076) (± 0.051) M/F 200cm Clear 25/ (± 0.076) (± 0.051) M/M 100cm Clear 25/ (± 0.076) (± 0.051) M/M 150cm Clear 25/ (± 0.076) (± 0.051) M/M 200cm Clear 25/ (± 0.076) (± 0.051) M/F 100cm Red 25/ (± 0.076) (± 0.051) M/F 150cm Red 25/ (± 0.076) (± 0.051) M/M 125cm Blue 25/ (± 0.076) (± 0.051) M/M 150cm Blue 25/ (± 0.076) (± 0.051) M/F 150cm Yellow 25/ (± 0.076) (± 0.051) ARGON PE PRESSURE MONITORING LINES (PolyEthylene) M/F 15cm Clear (Red/Blue Stickers) 25/ (± 0.05) 2.50 (+ 0.1/- 0.05) M/F 50cm Clear (Red/Blue Stickers) 25/ (± 0.05) 2.50 (+ 0.1/- 0.05) M/F 100cm Clear (Red/Blue Stickers) 25/ (± 0.05) 2.50 (+ 0.1/- 0.05) M/F 150cm Clear (Red/Blue Stickers) 25/ (± 0.05) 2.50 (+ 0.1/- 0.05) M/F 200cm Clear (Red/Blue Stickers) 25/ (± 0.05) 2.50 (+ 0.1/- 0.05) M/M 50cm Clear (Red/Blue Stickers) 25/ (± 0.05) 2.50 (+ 0.1/- 0.05) M/M 100cm Clear (Red/Blue Stickers) 25/ (± 0.05) 2.50 (+ 0.1/- 0.05) M/M 200cm Clear (Red/Blue Stickers) 25/ (± 0.05) 2.50 (+ 0.1/- 0.05) Argon Pressure Lines (PVC) for accurate transmission of the pressure waveform PVC Pressure Lines maximum pressure tolerance (fluid filled) 200 psi. Argon PE (PolyEthylene) lines as a non PVC alternative Colour coded stickers supplied with Argon PE to facilitate line identification PE Pressure Lines maximum pressure tolerance (fluid filled) 43 psi. Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC Shelf life: 5 years Model Content (Units) Product PRESSURE ACCESSORIES (Non-Sterile) TBG Transducer BackGround for pole mounting (up to 4 transducers) 10/ TMM Snap-On TMM Cable Organiser 5/ TMM/TBG TBG with Snap-On TMM Cable Organiser (P/Ns , ) 5/ Cable Checker Transducer tester for monitor calibration UMM Universal Manifold Mount 5/
49 Pressure Transducer Sets al Care catalogue /2/05 3:32 pm Page 20 BD Transducer Interface Cables Argon Transducer Interface Cables Argon supply compatible interface cables for the majority of currently available blood pressure monitors. Below are listed the most common interface cables for use with Argon s transducers. If your requirements are not listed please contact your local Argon office for assistance. BD supply compatible interface cables for the majority of currently available blood pressure monitors. Below is listed the most common interface cables for use with BD s transducers. If your requirements are not listed please contact your local BD office for assistance. When purchasing cables please specify: 1. Monitor type. 2. Model number and/or serial number. Non-sterile items When purchasing cables Latex please specify: free 1. Monitor type. 2. Model number and/or CE serial marked number. Class I according to European Medical Devices Directive 93/42/EEC as amended by Directive Non-sterile items. Class I according to European Medical Devices Directive 93/42/EEC 2007/47/EC Monitor Model Item Number Monitor No Monitor connection Model (Flying Leads) Product Brucker TM910M Criticare No Monitor Connection MATRIX, (Flying Scholar Leads) 2200 Shield: Dependent on Monitor. Black: + Signal; White: - Signal. Green: + Excitation; Red: - Excitation Criticon Criticon / GE Marquette Dynamap Dynamap Datascope All Models Datex Ohmeda Datascope (GE)/ Mindray SYS 800, All Models MOD 8641, (Passport, SIVA 3000 Accutorr, CS100/CS300 IABP) Dräger/Siemens 3rd Generation, 400 Series, 960, 961, Sirecust 4041, 700,1260, 342, 732, 342, 4XX, 7XX, 9XX, 12XX, Dräger PM8040, PM8060, Dräger Cato, Cicero & Julian Anes. Machine, Vitara Delta (SC7000), Kappa (SC8000), Delta XL (SC9000), with 10 pin connector Dräger/Siemens Siereg/Sicor 400 Series, BPA , (15-pole 961, Sirecust Cannon 4041, Connector), 700, 1260, Mingograph 342, 732, 6, Cathor, SC7000, Recor SC8000), SC9000), Infinity Gamma, Infinity Delta, Infinity Kappa, Dräger/Siemens Dräger / Siemens PM8040, Infinity PM8060, Vista all Dräger with Cato, 10 pin Cicero connector & Julian Anes. machine, Vitara Dräger/Siemens 6004, SC6002XL, SC6802XL, SC 6000P, 6002, 5000, Delta (SC7000), Kappa (SC8000), Dräger / Siemens Delta SC6000P, XL (SC9000), 6002, Gamma 5000, XL 6004, (SC6000) 7000, transport Infinity monitor, Gamma, all Infinity with 7 Delta, pin connector Infinity Kappa, Infinity Vista all with 7 pin connector Dräger/Siemens Dräger / Siemens HemoPod adapter Hemo Pod Adapter (One adapter for each Hemo2 Pod and two for each Hemo4/HemoMed Pod) E For M RM300 (E for M/Honeywell) Hellige E (Litton) for M 4th/5th RM300 Generation (E for / M/Honeywell) SMC 108 / Servomed / SMU 610, , SMU EVO Jostra GE / Datex Ohmeda GE Monitor with Datex-Ohmeda front end : SYS 800, MOD 8641, SIVA 3000, Cardiocap, Cardiocap II, AS3, S5, Aestiva, ADU(S5) and Aisys Kontron, Arrow Minimon 7131 etc, 7132 etc, K2000, 7272 / Supermon 7210 / Cart 2 Plus Balloon Pump, Oxford ACAT Marquette (GE) 7000 GE series, Monitor 7010 Mod with Marquette 7200 front end : 7009 / Tramscope Series(600SL) - Eagle-Solar 8000, Solar , Eagle3000/1000, Mab Lab 6Fx3F, GE / Marquette Marquette (GE) 7009 / Tramscope 450SL, Series(600SL) 6200, Tram600A, - Eagle-Solar EK36, 8000, Dash Solar 3000, 9000, Dash Eagle3000/1000, 4000, Dash 5000 Mab Lab 6Fx3F, Tram 450SL, 6200, Tram600A, EK36, Dash 3000, Dash 4000 Medical Jostra Measurement Systems UPS-2020 (4ft cable) Medical Measurement Systems Kontron, Arrow UPS-2020 (12ft cable) Minimon 7131 etc., 7132 etc., K2000, 7272 / Supermon 7210 / Cart 2 Plus Balloon Pump, Oxford ACAT Mennen Envoy NellcorMarquette (GE) Escort MDE Series, 7010 Mod Nihon Kohden MFV1100,1200,1230A; Lifescope 8, 9, 11, 12, 14,BSM-8300J/K, 3000, BSM Mindray PM8000, PM7000, PM9000, Spectrum; MEC Series; Passport/Spectrum Nihon Kohden NK9000 JP-900P Philips Mindray CM140 BeneView T5, T8, T1; IPM (8, 10, 12); BeneHeart D Phillips (Hewlett Packard) 78341A, 78342A, etc. / 78354C, 78205A-D, 12-pin / 78352, CMS (Merlin line), M1006A/B, Nellcor M1026A Escort / M1166A 300 MDE / Viridia / HP Scop Eurelie 24C, CMS2001, V24, V26, M2, M3, M4, Intelivue Physiocontrol/Medtronic Lifepack 12 (6 pin) Nihon Kohden MFV1100,1200,1230A; Lifescope 8, 9, 11, 12, 14,BSM-8300J/K, 3000, BSM4100 Physiogard Physiogard PPG Biomedical Nihon Kohden / Hellige / Marquette MIDAS; NK9000 Hellige Midas 5000, 2500, 2100 series JP-900P Protocol Propaq Protocol Propaq series; Propaq 106EL; PRUCKA ENG INC CARDIOLAB 78341A, II / 78342A, 1.1, AMP etc. II / 78354C, 78205A-D, 12-pin / 78352, CMS (Merlin line), M1006A/B, M1026A / M1166A / Viridia / HP Scop Eurelie Philips Quinton Q-cath 24C, lab system CMS2001, V24, V26, M2, M3, M4, Intelivue Schwarzer Physiocontrol/Medtronic MX960 Lifepack 12 (6 pin) Spacelabs Alpha 700 Series Spacelabs Protocol Propaq Series Protocol 400, 500, Propaq 90308/11/31, series; MOD-CD Propaq 106EL Spacelabs (Vitatek) / BCI 400, 500, 90485, Alpha-PC, 90603A,BCI 9100,90303B-Mod , CD-CV, 90369, 90385, Prucka Eng. Inc. Cardiolab II / 1.1, AMP II 90470, 90496, Ultraview Stockert Spacelabs S3 Series 400, 500, 90308/11/31, MOD-CD Stockert Heart Lung Machine Tektronics Spacelabs (Vitatek) / BCI 400 Series 400, 500, 90485, Alpha-PC, 90603A, BCI 9100, 90303B-Mod , CD-CV, 90369, 90385, 90470, , Ultraview Vitalert Stöckert (Sorin) S3 / S5 Vitatek Series 400, Zoll Stöckert (Sorin) Zoll Defribrillators Heart Lung Machine Tektronics 400 Series Vitalert Vitatek Series 400, Welch Allyn Zoll Zoll Defibrillators
50 Pressure Transducer Sets Pin F - LF Pin M - LF Datascope/Mindray All Models Passport, Accutorr, CS100/CS300 IABP Pin M - LF Criticon/GE Marquette Dynamap Mindray - PM/MEC Series, Spectrum Nellcor - Escort 300 MDE Physiocontrol (Medtronic) - Lifepack12 Protocol Propaq - Protocol Propaq series; Propaq 106EL; Spacelabs - Series 400, 500, 90308/11/31, MOD-CD, CD-CV Tektronics Series Vitalert 2000 Vitatek - Series 400, 500 Welch Allyn Zoll - Zoll Defribrillators Pin M - LF Philips CMS (Merlin line), M1006A/B, M1026A / M1166A / Viridia / HP Scop Eurelie 24C, CMS2001, V24, V26, M2, M3, M4, Intelivue Mindray BeneView T5, T8, T1; IPM (8, 10, 12); BeneHeart D Pin M - LF Nihon Kohden MFV1100,1200,1230A; Lifescope 8, 9, 11, 12, 14, BSM-8300J/K, 3000, BSM Pin M - LF Dräger/Siemens 400 Series, 960, 961, Sirecust 4041,700,1260, 342, 732, Sirecust 342, 4XX, 7XX, 9XX, 12XX SC7000, SC8000, SC9000, Infinity Gamma, Delta, Kappa, Vista all with 10 pin connector GE / Marquette 7000 series, 7010, Mod 7200
51 Pressure Transducer Sets Pin M - LF Pin M - LF GE / Marquette GE Monitor with Marquette front end : 7009 / Tramscope Series(600SL), Eagle-Solar 8000, 9000, 3000/1000, Mab Lab 6Fx3F, Tram 450SL, 6200, Tram600A, EK36, Dash 3000, Dash 4000, Dash 5000 E for M/Honeywell RM300 Dräger PM8040, PM8060, Dräger Vitara, Cato, Cicero & Julian Anes. machine, Philips CM Pin F - LF Pin M - LF GE / Datex-Ohmeda GE Monitor with Datex-Ohmeda front end : SYS 800, MOD 8641, SIVA 3000, Cardiocap, Cardiocap II, AS3, S5, Aestiva, ADU(S5) and Aisys Kontron, Arrow Minimon 7131, 7132 etc, K2000, 7272 / Supermon 7210 / Cart 2 Plus, Balloon Pump, Oxford ACAT Pin N/A - LF Pin M No Monitor Connection ( flying lead ) Wiring Guide: Green: (+) Excitation Voltage Red: (-) Excitation Voltage Black: (+) Signal White: (-) Signal Shield: Dependant on monitor specification Jostra (Heart pump)
52 Pressure Transducer Sets Pin M - LF Pin M - LF (identical to P/N ) Dräger/Siemens SC6000P, 6002, 5000, 6004, 7000, Infinity Gamma, Delta, Kappa, Vista all with 7 pin connector Pin M Spacelabs (Vitatek) BCI - 400, 500, 90485, Alpha-PC, 90603A, BCI 9100, 90303B-Mod , CD-CV, 90369, 90385, 90470, 90496, Ultraview Pin M Prucka Eng Inc. CARDIOLAB II / 1.1, AMP II Pin M Dräger/Siemens Hemo Pod Adapter (One adapter for each Hemo2 Pod & two for each Hemo4/HemoMed Pod) Pin M - LF Stöckert (Sorin) S3, S5 JP - 900P (OTCN KB559) Stöckert (Sorin) Heart Lung Machine Nihon Kohden NK9000
53 Pressure Transducer Sets Model: SP Model: SP4045 In-Line Injectate Sensor Cable For use with Abbott Oximetrix, Arrow, Baxter, Edwards 9520A or Com1, Mennen Horizon 2000 series (Cable ), Spacelebs Alpha PC or PCMS (bifurcated cable model ), Datex AS3 and Argon Critikit Injectate Set or SP5045 Sensor Housing In-Line Injectate Sensor Cable For use with Nihon Kohden, Spacelabs (bifurcated cable model ), Fukuda Denshi IB5006 (DSCP), Dynascope DS3300 and Argon Critikit Injectate Set or SP5045 Sensor Housing Model: SP Model: SP4046 In-Line Injectate Sensor Cable For use with Siemens bifurcated cable, Siemens Pod system (model ) and Argon Critikit Injectate Set or SP5045 Sensor Housing In-Line Injectate Sensor Cable For use with Philips Cardiac Output module (trifurcated cable M1641A or M1642A) and Argon Critikit Injectate Set or SP5045 Sensor Housing
54 24G 24G Critical Care catalogue /2/05 3:32 pm Page 21 Cannulae/Catheter Conversions Cannulae/Catheter Conversions Cannulae/Catheter Conversions Gauge outer Ø Charriere Charriere Gauge (SWG) Outer mm Ø Inch inch (French) (French) mm 1Ch 1 = Ch=0, mmmm Gauge outer Ø Charriere (SWG) 0,5 mm 0,019 inch (French) Ch=0,33 mm 24 0,6 0, , , ,7 0, , , ,8 0, , , ,9 0, , , ,0 0, , , ,1 0, ,0 0, , , ,1 0, , , ,2 0, , , ,3 0, , , ,4 0, , , ,5 0, ,7 0, , , ,8 0, , , ,9 0, , ,071 2,0 0, , , ,1 0, , ,079 2,2 0, ,1 0, ,3 0,091 2,2 0, , ,094 2,3 0, , , ,4 0, ,5 0, Cannulae/Catheter Conversions Outer Diameters/Gauge-French Sizes The definition Cannulae/Catheter of of gauge gauge measurement measurement comes Conversions comes from from the AAMI the AAMI (Association for the of Medical Outer for the Diameters/Gauge-French Advancement of Medical Instrumentation Sizes - USA). - This This states states how how many many cannulae cannulae fit into fit a tube into a with tube an with inner diameter an The inner definition of diameter 1 of (1 gauge inch of 1 = measurement 25.4mm). (1 inch = 25.4mm). comes from the AAMI (Association for the Advancement of Medical Instrumentation - USA). This states how many cannulae fit into a tube with an inner diameter of 1 (1 inch = 25.4mm). 1 inch 1 inch The AAMI AAMI uses uses only only even even numbers numbers (18, (18, 20, 22, 20, etc.) 22, as etc.) measuring as units. A similar measurement definition exists in Great Britain and measuring units. A similar measurement definition exists in this is known as the SWG (Standard Wire Gauge). The SWG uses Great Britain and this is known as the SWG (Standard Wire consecutive The AAMI uses numbers, only even ie 13 numbers to 24 and (18, is 20, the 22, more etc.) common as measuring method Gauge). units. A of similar The measurement SWG measurement uses for consecutive catheters definition in exists numbers, Europe. in Great The ie 13 Charriere, Britain to 24 and and commonly this the is more known known common as the as SWG French, method (Standard relates of measurement directly Wire Gauge). to the The catheter for catheters SWG size, uses ie 1 in consecutive Ch Europe. = 0.33mm. The numbers, Charriere, In the following 13 to commonly 24 tables and is the the known measurements more common French, of the AAMI relates method - SWG directly of measurement - French to the are catheter for shown catheters in size, relation in i.e. Europe. 1 to Ch the = The outer 0.33mm. Charriere, ø in mm. In the commonly following known tables as French, the measurements relates directly of to the AAMI catheter - SWG size, ie- Table French 1 Ch = 0.33mm. are shown In the in relation following SWG - AAMI to tables the outer the measurements ø in mm. of the AAMI - SWG - French are shown in relation to the outer ø in mm Outer Ø mm Table SWG - AAMI Outer Ø mm inch 1 inch 13G G G G 16G G 17G G 18G AAMI SWG AAMI BD s SWG multi lumen catheter (Careflow ) hub colour coding differentiates the white proximal lumens BD s multi and lumen not the catheter (Careflow ) brown hub tip colour catheter coding Argon s differentiates gauge, multi lumen ie catheter (Careflow blue TM ) hub colour white middle proximal lumens coding differentiates and not the the brown white proximal tip catheter lumens and gauge, not ie the brown blue tip middle catheter gauge, i.e. blue middle 13G G G G 16G G 17G G 18G G 20G G G G 22G 24G 24G G G G 21G G 22G 23G 23G Teflon, Tyvek registered to Dupont Inc. Nylon Teflon, registered Tyvek registered to Atrochem to Dupont Corporation Inc. BD, Nylon BD logo registered and all to other Atrochem trademarks Corporation are the property of Becton, Dickinson and Company BD BD, BD logo and all other trademarks are the property of Becton, Dickinson and Company BD 21 21
55 Appendix Quality Management with Argon Argon products are designed and manufactured to meet applicable international Quality Management System requirements in accordance with the European Medical Devices Directive 93/42/EEC (MDD) and FDA QSR where applicable. Hence, all Argon manufacturing sites hold a valid certification against ISO 9001:2000 and/or ISO 13485:2003. Likewise, all Argon manufacturing sites are subject of periodic external as well as internal audits to ensure compliance with aforementioned Quality Management System requirements. Symbol Guidance The CE mark, signifying compliance with European Medical Device Directive. Catalogue number/ reference number/ re-order number Serial number Lot number/batch code/batch number Fragile Authorised representative in the European Community Keep dry Sterilised using Ethylene Oxide Do not re-use/single use/use only once Use by Keep away from sunlight Date of manufacture Do not use if package is damaged Manufacturer Green Dot - Recycle in Europe This way up Caution/attention/see instructions for use Does not contain natural rubber latex Contains or presence of natural rubber latex Contains or presence of phthalates: Bis(2-ehylhexyl) phthalate (DEHP) Temperature limitation Rx ONLY Caution: Federal Law (USA) restricts this device to sale by or on the order of a physician! Caution, consult accompanying documents
56 Index
57 The Netherlands Argon Medical Devices Netherlands B.V. Registered address: Prins Bernhardplein JB Amsterdam The Netherlands Please send any correspondence to: Beech Avenue PW Schiphol-Rijk The Netherlands Tel: Fax: Germany Argon Medical Devices Netherlands B.V. Zweigniederlassung Deutschland Steinpilzweg Erlangen Deutschland Tel: +49-(0) Fax: +49-(0) Finland Argon Medical Devices Netherlands B.V. Suomen sivuliike Televisiokatu Helsinki Finland Tel: Fax: [email protected] Belgium Argon Medical Devices Netherlands B.V., Belgium Branch Noordlaan Dendermonde Belgium Tel: Fax: [email protected] Sweden Argon Medical Devices Netherlands B.V. Filial Sweden Stora Åvägen Askim Sweden Tel: +46 (0) Fax: +46 (0) [email protected] Denmark Argon Medical Devices Dronninggårds Alle Holte Denmark Tel: Fax: [email protected] UK Argon Medical Devices Netherlands B.V., UK Branch The Core Business Centre Milton Hill Abingdon, Oxfordshire OX13 6AB United Kingdom Tel: +44 (0) Argon Medical Devices Inc. All Rights Reserved. No reproduction of any portion of this work shall be made without prior permission of the author /0413B
The Argon Family of PICC and Midline Catheters. Providing Optimal Outcomes for Long-Term & Intermediate Therapies
The Argon Family of PICC and Midline Catheters Providing Optimal Outcomes for Long-Term & Intermediate Therapies Introducers Safety MST Accessory Kits Safety MST Accessory Kits for PICC and Midline Placement
SUCTION, ASPIRATING TUBES
162300 536204 162345 162301 (shown twice size) Yankauer Suction Tubes YANKAUER SUCTION TUBES Standard adult size. 10 mm diameter. Tip has 2 mm central opening and four 2 mm side openings. 162300 12 1/2"
Freka. Enteral Feeding Tube Product Range ENTERAL NUTRITION
ENTERAL NUTRITION Freka Enteral Feeding Tube Product Range Fresenius Kabi Limited, Cestrian Court, Eastgate Way, Runcorn, Cheshire WA7 1NT tel: 01928 533533 fax: 01928 533520 email: [email protected]
Joline - a modern medical technology company built on tradition. For further information please contact us!
Long Term Joline - a modern medical technology company built on tradition has built on a long tradition in the development and production of dialysis catheters and has been manufacturing medical products
1-800-962-9888. Table of Contents. Acute Vascular Access. Chronic Vascular Access
Dialysis Products 1-800-962-9888 Table of Contents Acute Vascular Access MAHURKAR * Protection and Safety Solution (PASS) Trays... 3 Safety Catheter Insertion Tray (SCIT)... 4 Argyle Personal Protective
Ureteral Pig tail Stent Sets
Ureteral Pigtail Stent Sets Steerable Ureteral Pigtail Stent Sets both ends open A pre-assembled introducer system consisting of an inner catheter (transparent) with luer lock attachment and a positioning
When Procedural Support really matters. Navien TM A+ Intracranial Support Catheter
When Procedural Support really matters Navien TM A+ Intracranial Support Catheter Coils / Liquid Embolics DURABLE ovalization resistance, Maintains patent lumen in tortuosity for smooth micro catheter
Patient Information Guide Morpheus CT Peripherally Inserted Central Catheter
Patient Information Guide Morpheus CT Peripherally Inserted Central Catheter IC 192 Rev C A measure of flexibility and strength. Table of Contents 1. Introduction 2. What is the Morpheus CT PICC? 3. What
Tracheal Stent System
nt Tracheal Stent System Available sizes: 08mm x 20mm NEW 08mm x 30mm 08mmx 50 mm 08mm x 60mm 08mm x 70mm 08mm x 80mm 08mm x 90mm 10mm x 20mm NEW 10 mm x 30 mm 10 mm x 50 mm 10 mm x 60 mm 10 mm x 70 mm
PATIENT GUIDE. Understand and care for your peripherally inserted central venous catheter (PICC). MEDICAL
PATIENT GUIDE Understand and care for your peripherally inserted central venous catheter (PICC). MEDICAL Introduction The following information is presented as a guideline for your reference. The best
Hemostasis Solutions Boston Scientific is committed to improving patient care in the management of gastrointestinal bleeding.
Hemostasis Solutions Boston Scientific is committed to improving patient care in the management of gastrointestinal bleeding. Through innovation and continuous educational support, we offer a wide range
X-Plain Subclavian Inserted Central Catheter (SICC Line) Reference Summary
X-Plain Subclavian Inserted Central Catheter (SICC Line) Reference Summary Introduction A Subclavian Inserted Central Catheter, or subclavian line, is a long thin hollow tube inserted in a vein under the
Coloplast Product Guide Ostomy, Continence, Wound & Skin Care. Effective March 2010
Coloplast Guide Ostomy, Continence, Wound & Skin Care Effective March 2010 SpeediCath TM Intermittent Catheters The only ready-to-use hydrophilic catheter. Clinical research indicated that twice as many
Policies & Procedures. I.D. Number: 1073
Policies & Procedures Title:: CENTRAL VENOUS CATHETERS INSERTION ASSISTING I.D. Number: 1073 Authorization [] Pharmacy Nursing Committee [] MAC Motion #: [x] SHR Nursing Practice Committee Source: Nursing
Kimberly-Clark Healthcare Catalogue Digestive Health. Digestive Health
Kimberly-Clark Healthcare Catalogue Digestive Health Digestive Health Table of Contents Table of contents Enteral Feeding...1 Gastric Access Feeding Tubes and Placement Kits...1 KIMBERLY-CLARK* MIC G*,
PERIPHERALLY INSERTED CENTRAL CATHETERS (PICC) Fong So Kwan APN, Haematology unit Medical Department, QMH
PERIPHERALLY INSERTED CENTRAL CATHETERS (PICC) Fong So Kwan APN, Haematology unit Medical Department, QMH 1 What is a PICC catheter? Primary vascular access device since their introduction in the mid-1970s,
Central Venous Catheters for Veterinary Technicians
Central Venous Catheters for Veterinary Technicians Erica Mattox, CVT, VTS (ECC) Central venous catheterization is passing a long catheter into a large vein, such as the jugular or caudal vena cava. This
Morpheus SMART PICC CT Insertion Kit
Morpheus SMART PICC CT Insertion Kit Peripherally Inserted Central Catheter INSTRUCTIONS FOR USE ANGIODYNAMICS, INC. 603 QUEENSBURY AVE. QUEENSBURY, NY 12804 U.S.A. TOLL FREE: 800-772-6446 PHONE: 518-798-1215
Deflectable & Steerable Catheter Handbook
Deflectable & Steerable Catheter Handbook Terminology Guide & Design Options www.cregannatactx.com California Minnesota Ohio Ireland Singapore Terminology Steering v s Deflection Steerability This refers
Urology Extended Care
Urology Extended Care Urology Extended Care Covidien s mission is to provide quality urological devices delivering powerful benefits to physicians, caregivers, and patients. Covidien offers a comprehensive
I-140 Venipuncture for Blood Specimen Collection
I-140 Venipuncture for Blood Specimen Collection Purpose Obtain a blood specimen by venipuncture for laboratory analysis using aseptic technique. Applies To Registered Nurses Licensed Practical/Vocational
PICC & Midline Catheters Patient Information Guide
PICC & Midline Catheters Patient Information Guide medcompnet.com 1 table of contents Introduction 4 What is a PICC or Midline Catheter? 4 How is the PICC or Midline Catheter Inserted? 6 Catheter Care
SUCTION & TUBING YANKAUER, POOLE, FRAZIER AND SIGMOID INSTRUMENTS PREMIUM CONNECTORED AND ECONOMY ROLL TUBING
SUCTION INSTRUMENTS & TUBING YANKAUER, POOLE, FRAZIER AND SIGMOID INSTRUMENTS PREMIUM CONNECTORED AND ECONOMY ROLL TUBING A complete line of quality, disposable Suction Instruments and Tubing to meet your
HAND INSTRUMENTS. HiQ+ Monopolar Hand Instruments Needle Holders Suction and Irrigation Monopolar HF Electrodes. THE HiQ+ SERIES
HAND INSTRUMENTS HiQ+ Monopolar Hand Instruments Needle Holders Suction and Irrigation Monopolar HF Electrodes THE HiQ+ SERIES CONTENTS FORM FOLLOWS FUNCTION FOLLOWS YOUR NEEDS HiQ+ Monopolar and Standard...4
Introcan Safety. 1 billion times protection. Vascular Access
Introcan Safety 1 billion times protection Vascular Access The B. Braun Introcan Safety IV Catheter Reduces Needlestick Injuries Passive Safety Technology Established worldwide: B. Braun has minimized
Discover a new approach to vertebral augmentation
Discover a new approach to vertebral augmentation AVAmax Advanced Vertebral Augmentation system The AVAmax vertebral balloon and AVAflex curved needle allowed a uniform cement fill during this pictured
Aspira* Peritoneal Drainage Catheter
Aspira* Peritoneal Drainage Catheter Instructions For Use Access Systems Product Description: The Aspira* Peritoneal Drainage Catheter is a tunneled, long-term catheter used to drain accumulated fluid
Chester Chest Model 2400 User s Manual
Chester Chest Model 2400 User s Manual 308 South Sequoia Parkway, Canby, Oregon 97013 USA ph. 503.651.5050 fax 503.651.5052 email [email protected] Thank You For Your Purchase! Thank you for your purchase
Vaxcel PICCs Valved and Non-Valved. A Patient s Guide
Vaxcel PICCs Valved and Non-Valved A Patient s Guide Information about your Vaxcel PICC is available by calling the Navilyst Medical Vascular Access Information Line 800.513.6876 Vaxcel Peripherally Inserted
Placement of Epidural Catheter for Pain Management Shane Bateman DVM, DVSc, DACVECC
Placement of Epidural Catheter for Pain Management Shane Bateman DVM, DVSc, DACVECC Indications: Patients with severe abdominal or pelvic origin pain that is poorly responsive to other analgesic modalities.
Helping to protect you from exposure to hazardous drugs
Helping to protect you from exposure to hazardous drugs Closed system solution: Texium closed male luer and SmartSite needle-free valve products What you can t see can hurt you The risks are well documented
TURQUOISE PTCA BALLOON DILATATION CATHETER
TURQUOISE PTCA BALLOON DILATATION CATHETER TURQUOISE PTCA BallOOn Dilatation CATheter The right BAlance TO meet the clinical need TURQUOISE PTCA s advanced catheter technology offers the right balance
Policy and Procedure Flushing and / or Blood withdrawal Aspiration Procedure For PICC Line and Midline Catheters
Policy and Procedure Flushing and / or Blood withdrawal Aspiration Procedure For PICC Line and Midline Catheters Purpose: Blood Withdrawal: To obtain blood samples for laboratory evaluation, eliminating
Instructions for Use. Device Description The AMPLATZER Vascular Plug II is a self-expandable nitinol mesh occlusion device (see Figure 1).
Vascular Plug II Instructions for Use Device Description The AMPLATZER Vascular Plug II is a self-expandable nitinol mesh occlusion device (see Figure 1). A B Figure 1. AMPLATZER Vascular Plug II A. Nitinol
Aspira* Pleural Drainage Catheter
Aspira* Pleural Drainage Catheter Instructions For Use Access Systems Product Description: The Aspira* Pleural Drainage Catheter is a tunneled, long-term catheter used to drain accumulated fluid from the
Peripherally Inserted Central Catheter (PICC) for Outpatient
Peripherally Inserted Central Catheter (PICC) for Outpatient Introduction A Peripherally Inserted Central Catheter, or PICC line, is a thin, long, soft plastic tube inserted into a vein of the arm. It
Expect. Endoscopic Ultrasound Aspiration Needles. Your Patient. Your Needle. Your Preference.
Expect Endoscopic Ultrasound Aspiration Needles Your Patient. Your Needle. Your Preference. Expect Slimline (SL) Endoscopic Ultrasound Aspiration Needles With applications for endoscopic ultrasound and
Clinician Competency:
Thanks to CR Bard Clinician Competency: INS (Intravenous Nursing Society) recommends that an institution create a set criteria to evaluate the competency of nurses learning to place PICC Line / Midline
BD Saf-T-Intima. Hidden talents of BD Saf-T-Intima. BD SAF-T-Intima and SUBCUTANEOUS THERAPY REHYDRATION PALLIATIVE CARE. POST OPERATIVe PAIN RELIEF
Hidden talents of BD Saf-T-Intima BD Saf-T-Intima SUBCUTANEOUS INFUSION REHYDRATION PALLIATIVE CARE BD SAF-T-Intima and SUBCUTANEOUS THERAPY PAEDIATRIC CARE POST OPERATIVe PAIN RELIEF BD Saf-T-Intima First
A Global Leader in Hypodermic Products
A Global Leader in Hypodermic Products Hypodermic Product Catalog A Complete Line of Medication Administration and Safety-Engineered Products For The Healthcare Industry BD Insulin Syringes (sterile, single
Hypodermic Product Catalog. The Basis for Selection of Your Medication Delivery Device Needs
Hypodermic Product Catalog The Basis for Selection of Your Medication Delivery Device Needs Interlink System and BD Cannulas Interlink Cannula Products for use with Interlink System 303367 Vial Access
NIH Clinical Center Patient Education Materials Giving a subcutaneous injection
NIH Clinical Center Patient Education Materials What is a subcutaenous injection? A subcutaneous injection is given in the fatty layer of tissue just under the skin. A subcutaneous injection into the fatty
Selection & Use of Surgical Needles
Selection & Use of Surgical Needles EThALLOy * INTELLIGENT GEOMETRy ADVANCED NEEDLE COATING The Selection & Use of Surgical Needles EThICON Products needles are manufactured in a wide range of types, shapes,
PICC and Midline Catheters
PICC and Midline Catheters Infusion RN s Deb Bucher RN BSN CRNI Dawn Finch RN CRNI Marianne Hansen RN BSN CRNI Karman Youngblood RN BS CRNI Infusion Pharmacist Kathy Cimakasky Pharm D Tamara Migut RPh
PRACTICE GUIDELINE TITLE: INTRAVENOUS LINE INSERTION: PERIPHERAL AND CENTRAL
PRACTICE GUIDELINE Effective Date: 9-17-04 Manual Reference: Deaconess Trauma Services TITLE: INTRAVENOUS LINE INSERTION: PERIPHERAL AND CENTRAL PURPOSE: To outline the indications and options for intravenous
Anesthesia Products Needles. Anesthesia Products Trays. Antimicrobial Products. Hypodermic/Diabetes Care Products. Hypodermic/Reusable Products
2014 2015 Sections A1 A2 B C D E F G H I J K L M Anesthesia Products Needles Anesthesia Products Trays Antimicrobial Products Flush Products Hypodermic/Diabetes Care Products Hypodermic/Reusable Products
Surgical scissors and forceps Product List
Surgical scissors and forceps Product List Sr. No Items Picture of Product Product specification 1 Grasping forceps-- 5 MM Grasping forceps are used to remove stones and retrieve foreign objects under
PICCs and Midline Catheters
Patient Education PICCs and Midline Catheters Patient s guide to PICC (peripherally inserted central catheter) and midline catheters What are PICCs and midline catheters used for? Any medicine given over
To maintain a port of entry to venous flow when all available peripheral ports have failed.
I. Purpose: To maintain a port of entry to venous flow when all available peripheral ports have failed. II. General Comments: Since its development, these catheters have been used with increasing frequency
Bard Access Systems, Inc. How to Care For Your. Nursing Guide
Bard Access Systems, Inc. How to Care For Your Nursing Guide Table of Contents Introduction 1 Product Description Placement PowerPICC SOLO* Catheter Valve Function Indications for Use Catheter Irrigation
Placement of an indwelling urinary catheter in female dogs
Female Dog Urinary Catheterization 1 of 6 Placement of an indwelling urinary catheter in female dogs Bernie Hansen DVM MS North Carolina State University College of Veterinary Medicine Materials Needed
Power Injectors for Diagnostic Imaging
Power Injectors for Diagnostic Imaging Contrast under Control A resource for all your contrast delivery needs Contrast under Control 2 1 3 Mallinckrodt provides contrast delivery systems for Computed
Vascular Access. Chapter 3
Vascular Access Chapter 3 Vascular Access Introduction Obtaining vascular access in infants and children can be difficult even under optimal conditions. Attempting emergent access in a hypotensive, struggling
A Practical Guide for the selection and use of prefilled Syringes for flushing vascular access devices. Paul Parisien, MedXL inc., Montreal, Canada.
A Practical Guide for the selection and use of prefilled Syringes for flushing vascular access devices. Paul Parisien, MedXL inc., Montreal, Canada. OBJECTIVE The objective of this report is to provide
PICC/Midclavicular/Midline Catheter
47 PICC/Midclavicular/Midline Catheter Introduction- PICC/ MCV/ Midline You have a PICC/Midclavicular/Midline (peripherally inserted) catheter. This catheter should make receiving I.V. medicines or solutions
The Arrow SureBlock Spinal Anesthesia Collection:
The inner contours of the introducer hub are designed with a precision fit to prevent damage to the atraumatic tip of the spinal needle during the introduction process Extensively Polished Stainless Steel
Appendix L: Accessing/Deaccessing Implanted Central Venous Access Port
Effective Date: 03/01/2008 Page 1 of 5 Recommendations for Use Insertion Considerations Implanted Port Dressing Access/ Reaccess An implanted port is strongly recommended for patients in whom more than
PROCEDURE FOR SUBCUTANEOUS INSERTION, REMOVAL, MEDICATION ADMINISTRATION AND FLUID ADMINISTRATION FOR COMMUNITY PALLIATIVE CARE PATIENTS
PROCEDURE FOR SUBCUTANEOUS INSERTION, REMOVAL, MEDICATION ADMINISTRATION AND FLUID ADMINISTRATION FOR COMMUNITY PALLIATIVE CARE PATIENTS Approved: February 2010 Date for review: February 2010 1 PROCEDURE
847-367-7771 BRUDER LAPAROSCOPY BRUDER 5 MM Ø LAPAROSCOPIC INSTRUMENTS BRUDER MULTI-FUNCTIONAL STYLE LAPAROSCOPIC INSTRUMENT
Serving the Medical Profession Since 1990 847-367-7771 BRUDER LAPAROSCOPY BRUDER SURGICAL INSTRUMENTATION By ARROW MEDICAL SUPPLY INC BRUDER 5 MM Ø LAPAROSCOPIC INSTRUMENTS Bruder is one of the leaders
PRODUCT CATALOGUE RESULTS OF THE SCIENTIFIC PROCESS
PRODUCT CATALOGUE RESULTS OF THE SCIENTIFIC PROCESS 2 disera RESULTS OF THE SCIENTIFIC PROCESS INDEX About Us 4 Production and Quality Certificates 5 VACUSERA Blood Collection Systems 6 VACUSERA Blood
KwikPen Insulin delivery device
USER MANUAL KwikPen Insulin delivery device PLEASE READ THESE INSTRUCTIONS BEFORE USE Lilly Introduction The KwikPen is designed for ease of use. It is a disposable pen containing 3 ml (300 units) of U-
Care for your child s Central Venous Catheter (CVC)
Care for your child s Central Venous Catheter (CVC) This booklet is intended for general informational purposes only. You should consult your doctor for medical advice. Please call the clinic or your home
Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery.
Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery. Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants approved by
Ward 29 guide to the safe preparation and administration of intravenous (IV) antibiotics at home
Ward 29 guide to the safe preparation and administration of intravenous (IV) antibiotics at home Contents Page Important contact numbers 1 General information on preparing and administering IV antibiotics
A PROCEDURAL GUIDE TO MIDLINE CATHETER INSERTION
A PROCEDURAL GUIDE TO MIDLINE CATHETER INSERTION See Also CPG midline catheters for indications, contraindications and post insertion management What is a midline A midline catheter is an 8-12 cm catheter
Managing Your Non-Tunneled (Percutaneous) Catheter: PICC, SICC, and JCC. What is a PICC catheter?
Managing Your Non-Tunneled The staff of the Procedure, Vascular Access, Conscious Sedation Service has written this information to explain your new PICC (peripherally inserted central catheter), SICC (subclavian
Nursing Management of Venous Access Devices: Peripheral IV lines
Nursing Management of Venous Access Devices: Peripheral IV lines Mimi Bartholomay, RN, MSN, AOCN Denise Dreher,, RN, CRNI, VA-BC Theresa Evans, RN, MSN Susan Finn, RN, MSN, AOCNS Debra Guthrie, RN, CRNI
SciTech, sro Praha Ceník Jour Research tisk 3.1.2000
Ceny bez DPH, balného a poštovného. Jour Research pricelist 08/99 Part Number Description cena CZK 0001-0737 Wash-Pro Upgrade Kit 7098,00 0001-5530 Gas Flow Meter 22932,00 0001-5531 Silicon Connection
Flushing and Dressing a Peripherally Inserted Central Catheter (PICC Line): a Guide for Nurses
Flushing and Dressing a Peripherally Inserted Central Catheter (PICC Line): a Guide for Nurses Information for Nurses Introduction This information is for community nursing staffs who have been asked to
8 French Double-Lumen Central Venous Catheter
8 French Double-Lumen Central Venous Catheter Instructions for Use *C_T_UDLM_REV2* 2 1 11 2 Fig. 1 Fig. 2 8 FRENCH DOUBLE-LUMEN CENTRAL VENOUS CATHETER CAUTION: U.S. federal law restricts this device to
Total Cardio Thoracic Solutions
1 Total Cardio Thoracic Solutions Cardio Thoracic Solutions Contents SENTINEL SEAL The Unique four-chamber Chest Drainage Concept Argyle ALTITUDE Three Chamber System Argyle Aqua-Seal Three Chamber System
LEADER IN CUTTING TECHNOLOGY
LEADER IN CUTTING TECHNOLOGY FOR OVER 2 YEARS REASONS WHY TRONEX IS THE BEST IN THE WORLD 1 2 SUPERIOR CUTTING PERFORMANCE Cut hundreds of thousands of times before dulling. Cut hundreds of thousands of
ON-Q * Catheters and Introducers
Instructions For Use ON-Q * Catheters and Introducers MANUFACTURED BY: Kimberly-Clark 1400 Holcomb Bridge Road Roswell, GA 30076 USA Kimberly-Clark N.V. Da Vincilaan 1 1935 Zaventem, Belgium Figure 1 4
ClikSTAR - Important facts about your new insulin delivery device.
ClikSTAR - Important facts about your new insulin delivery device. Instruction for Use ClikSTAR Insulin delivery device Before you start: Read these instructions and follow them completely each time you
CataLoG No. weight o.d. i.d. GLaSSwaRe
Lead weights with Vikem Vinyl Coating Protect and Stabilize Expensive Glassware Stabilizes vessels in water baths and on benchtops Added insurance against tipping and possible chemical spills Closed ring
OVER 45 YEARS TEXTILE GRAFT TECHNOLOGY EXPERIENCE MAQUET THE GOLD STANDARD
OVER 45 YEARS TEXTILE GRAFT TECHNOLOGY EXPERIENCE MAQUET THE GOLD STANDARD A comprehensive, proven vascular graft portfolio and exceptional professional support make MAQUET Cardiovascular a valuable asset
Shiley Product Guide. Shiley TM XLT Extended-Length Tracheostomy Tubes. Shiley TM Disposable Inner Cannula
Shiley Product Guide Shiley TM XLT Extended-Length Shiley TM Disposable Inner Cannula Shiley TM Percutaneous Disposable Inner Cannula Shiley TM Accessories for Disposable Inner Cannula Tubes Shiley TM
BioFlo PICC. with ENDEXO Technology. Directions For Use... 3 2014-03 14600133-01 A
BioFlo PICC with ENDEXO Technology Directions For Use... 3 14600133-01 A 2014-03 2 Table of Contents warning...4 device description...4 Figure 1. Catheter Configurations...4 Intended use/ Indications for
Objectives At the completion of this module, unlicensed assistive personnel (UAP) should be able to:
Objectives At the completion of this module, unlicensed assistive personnel (UAP) should be able to: 1. administer medications by subcutaneous injections. 2. document medication administration in the client
ArtisanLink Staining System is an automated special stains slide
Technical Tips Tips on using the ArtisanLink Special Staining System Jamie Nowacek, BS, HT(ASCP) CM, QIHC, PMP Dako North America, Inc. Carpinteria, CA, USA ArtisanLink Staining System is an automated
EUROTUBO DELTALAB 4. PETRI DISHES AND LOOPS
77 78 90 x 14 mm Petri Dish Made in polystyrene. Vented. Supplied in groups of 20 units, packaged in heat sealed bags. Code 200200 is ASEPTIC. Code 200209 is sterile by gamma radiation. Suitable for automatic
PERCUTANEOUS PD CATHETER IMPLANTATION SYSTEM
Place on Patient s Cranial Border of the Pubic Symphysis IMPLANTATION STENCIL Classic Exit Cuff Site PERCUTANEOUS PD CATHETER IMPLANTATION SYSTEM INSTRUCTIONS FOR USE VP 511 and VP-511M Implantation System
TREATMENT 1. Control bleeding by applying pressure over wound with Gauze Pads (Surgical Supply-4). 2. Contact Surgeon for laceration repair options.
Page 1 of 8 pages NOTE Contact Surgeon before giving any medication marked with an asterisk. In an emergency or during Loss of Signal, begin appropriate treatment; then call Surgeon as soon as possible.
HLS Set Advanced Integration meets innovation
HLS Set Advanced Integration meets innovation This document is intended to provide information to an international audience outside of the US. HLS Set Advanced circulatory and/or respiratory assist A
Instructions and User Guide. Select Series: Vascular Access Ultrasound Training Models BPO100, BPBV110, BPP120, BPNB150. June 8, 2011 Rev 2.
Instructions and User Guide Select Series: Vascular Access Ultrasound Training Models BPO100, BPBV110, BPP120, BPNB150 June 8, 2011 Rev 2.1 Contents 3 Chapter 1: Overview 3 Giving you the confidence only
Tubing and Accessories
Section 7 Tubing and Accessories Inch Industrial Tubing................................FIT-7-2 Metric Industrial Tubing...............................FIT-7-3 Inch D.O.T. Tubing...................................FIT-7-3
Page 1 of 10 MC1482 Peripherally-Inserted Central Catheter. Peripherally-Inserted Central Catheter (PICC)
Page 1 of 10 MC1482 Peripherally-Inserted Central Catheter Peripherally-Inserted Central Catheter (PICC) Page 2 of 10 MC1482 Peripherally-Inserted Central Catheter Introduction A peripherally-inserted
Safe medication. Disposable syringes
Safe medication Disposable syringes Disposable syringes Safe medication Safety, reliability, and accuracy down to the smallest detail as with all other CODAN Products, this commitment also holds true for
A4.7 Management of a totally occluded central catheter and persistent withdrawal occlusion (PWO)
A4.7 Management of a totally occluded central catheter and persistent withdrawal occlusion (PWO) Types of Catheter Related Thrombotic A catheter-related thrombus may be intraluminal (inside the catheter)
Innovation for optimized outcomes
Innovation for optimized outcomes VASOVIEW Endoscopic Vessel Harvesting Systems MAQUET MAQUET Medical Systems Medical USA Systems VASOVIEW USA PRODUCT EVH SYSTEMS NAME 31 Minimally invasive endoscopic
Plasmax Plasma Concentration System BIOLOGICS
Plasmax Plasma Concentration System BIOLOGICS Plasmax Plasma Concentration System Plasmax Plasma Concentrate System Contains Plasmax concentrator GPS III separator Provides 16ml of autologous output, 6ml
Sample Policy. Policy and Procedure PICC Line (Peripherally Inserted Central Catheter)
Policy and Procedure PICC Line (Peripherally Inserted Central Catheter) Policy: Product Description and Indications: The Per-Q-Cath PICC Line and the Groshong PICC Line is indicated for short or long term
Installation instruction CASAFLEX - Connecting piece DN 100
1 CASAFLEX - 11 10 114,3 x 4,5 3 5 2 4 1 7 6 8 12 9 Do not begin work until you have read the installation instruction carefully. 1 internal backing sleeve 2 graphite packing 3 connecting piece 4 thrust
POSSIBLE NURSING DIAGNOSIS: Pain Potential for Infection / Infection Fluid volume deficit
1 Procedure for Subcutaneous Over-the-needle Cannula Insertion, Removal, Medication Administration, and Fluid Administration for the Individual in the Home PURPOSE: To provide medication via the subcutaneous
Guy s, King s and St Thomas Cancer Centre The Cancer Outpatient Clinic Central venous catheter: Peripherally inserted central catheter
Guy s, King s and St Thomas Cancer Centre The Cancer Outpatient Clinic Central venous catheter: Peripherally inserted central catheter This information leaflet aims to help answer some of the questions
1-800-862-2731 Administration of Meropenem For Child
1 Drug Name: _Meropenem 1-800-862-2731 Administration of Meropenem For Child Dosage: milligrams every hours over 5 minutes Key Points: FLUSHING: Meropenem Heparin flush 1. Always wash your hands with an
Red rubber all-purpose urethral. Catheters. Bard Clean-Cath Intermittent catheter: 802408-22 8-22 Fr. 100/case
BARDIA Urethral Catheters Red rubber all-purpose urethral catheters: Radiopaque red rubber catheter with a round, hollow tip Can be used as a Robinson or a Nelaton catheter Two opposing drainage eyes 16
TITLE CLIN_216 HEMODIALYSIS/PLASMAPHERESIS PROCEDURE AND CATHETER MANAGEMENT FOR THE ADULT AND PEDIATRIC PATIENT
Policies and procedures are guidelines and are not a substitute for the exercise of individual judgment. If you are reading a printed copy of this policy, make sure it is the most current by checking the
Patient Information. PORT-A-CATH Implantable Venous Access Systems
Patient Information PORT-A-CATH Implantable Venous Access Systems Your doctor has prescribed treatment that requires the frequent administration of medications or other fluids directly into your bloodstream
Cables. Accessories. For Force, Torque and Strain Sensors
Accessories Cables For Force, Torque and Strain Sensors Charge mode, high impedance piezoelectric measurement demands highly insulated coaxial cables and connectors to ensure an insulation resistance greater
