Integrated Home Networks

Size: px
Start display at page:

Download "Integrated Home Networks"

Transcription

1 Integrated Home Networks 8050 Series elephone/data Hubs Instruction Manual & Structured Wiring Guide multiplex technology, inc Enterprise Street, Brea, CA , U.S.A * * FAX_

2 Data/elephone Hub applications POS (Plain Old elephone Service) 8053 o distribute POS, use either an 8051 or an All connectors are bridged ( wired in parallel ). Use a model 8053 to distribute telephone service. A single model 8053 can handle up to 9 telephones. For more phones, add one 8053 for every 8 telephones. All connectors are bridged (wired in parallel.) From elco Central Office lines (CO) CO1, CO2, CO3, CO Expansion connector 8051 Use a model 8051 to distribute telephone service if you prefer to use modular connectors. he model 8051 also provides loopthrough on pair 1 for a security system or a Doorel front door intercom. All connectors are bridged (wired in parallel.) In a structured wiring system, a model 8051 is used to provide selective telephone service. (See the section on Structured Wiring Systems.) Jacks accept 6 position J-25 Or 8 position J-45 plugs o phone jacks 110 punch-down blocks Do not punch-down more than one wire per connector In a structured wiring system, a model 8052 is used to provide a termination point for all internal house wiring. (See the section on Structured Wiring Systems.) Each modular connector is individually connected to the 110 punch-down block behind it. ie wrap mounting holes From elco Central Office lines (CO) CO1, CO2, CO3, CO4

3 Wire Color Codes elephone ermination Band -Stripe wisted-pair Wire Cat5 4 pair UP pair 1 pair 2 blue/white blue orange/white orange Solid Color wisted-pair Wire green IP red ING black IP yellow ING Option 1 - old style Dual Jack elephone Wallplate Orange White/Orange Blue White/Blue Black Yellow ed Brown Pairs 1&2 pair 3 green/white IP white White/Brown pair 4 green brown/white brown ING IP ING blue White/ Black Yellow ed Quad Wire* pair 1 green red IP ING CAUION: Quad wire is no longer acceptable for installations in multi-line environments. etrofit with UP if possible. Pairs 3&4 pair 2 black yellow ACCESSOY GOUND Option 2 - new style Quickport wallplate Cable Color Pin # Connector Color Pin 1 N/C White/Orange Pin 2 White/Orange Blue Pin 3 Blue White/Blue Pin 4 White/Blue Orange Pin 5 Orange Pin 6 N/C Modular connector designations Pairs 1&2 6 position connectors P1 P2 P1 P3 P2 P Pairs 3& J-11 Single line telephones, answering machines 8 position connectors P2 P3 P1 P J-14 J-25 Dual line telephones are & answering 3 line KSU hookups machines J-45 (wired to IA 568A standard) Ethernet (both 10Base and 100Base) Structured wiring of phones and data lines (here are other wiring standards. For residential use, w e recommend that J-45 jacks are wired to the 568A standard.) Cable Color Pin # Connector Color Pin 1 N/C White/Brown Pin 2 White/Orange Pin 3 Blue White/ Pin 4 White/Blue Brown Pin 5 Orange Pin 6 N/C J-14 Voice Grade Jacks 8072

4 How to wire a new house he Internet, multiple phone lines, cable television, satellite systems, and high speed data links are bringing more and more information to your home. he communication wiring in most houses is overwhelmed by these requirements. It doesn t have to be that way. During construction, providing modern cabling is surprisingly inexpensive. un all wires to a network enclosure. In a typical house, an in-wall cabinet located at the media center will be a good choice. (Large houses may need two or more cabinets to service all of the wires. Since these large cabinets can be unsightly, they are usually placed in a garage, basement, or service room.) Home-run CA-5 and coax cables from each location 2 G-6 to location of satellite dish ypical wallplates Phone only V only When wiring a new house: 1) Establish a distribution point for all data, telephone and coax cables. 2) When possible, have a network enclosure at this location. 3) un cables from each wall outlet back to the network enclosure. his is called home run or star wiring. 4) When in doubt, add the extra wires. When a house is being built, running extra cables is easy. Once the wall board is up, that extra cable will cost 10 times as much. Family room Media center Living room Master suite Determine the wiring scheme that is right for you: Standard: 1 Cat-5 cable to all possible telephone and computer modem locations. 1 G-6 coax to all possible V locations (except the media niche). 3 G-6 coax cables to the media niche (to satellite receiver, to V, from modulator). 2 Cat-5 cables to telephone company entry location. 1 G-6 coax cable to CAV entry point (2 if you have a dual coax cable.) 2 G-6 coax cables to location of satellite dish. Options to the above, add any or all of the following: 1 Cat-5 cable to all computer or printer locations for a home network. nd 2 G-6 coax to all V locations for modulator inputs or satellite feed. 1 G-6 coax + 1 Cat-5 cable to front door for CCV camera and Doorel intercom. 1 G-6 coax and bell wire to any other possible CCV camera locations (swimming pool, side yard, driveway.) he ultimate where cost is no object, solution: Conduit to all locations. emember to install pull cords in conduit. Kitchen 1 G-6 and 1 Cat-5 to front door for intercom and camera. Utility access cabinet Phone lines from elco Coax from cable company Wallplates holes holes holes, dbl gang holes Decora Bedroom Bedroom Home office Home office wallplate has 4 telephone lines, data line, & CAV Jacks conductor J-25 white conductor J-25 gray conductor J-45 blue F connector white F connector gray blank white Consult the ChannelPlus dealer catalog for other wallplate and connector options.

5 Wiring the 8051 and 8400 he Doorel system allows you to answer your front door from any telephone in the house. When the doorbell rings, pick up the nearest extension and press #. Now you may have a two-way conversation with the person ringing the bell. Doorel Front Door model 8400 Speaker/microphone model 8410 Structured wiring basics: Phones today, data or KSU tomorrow From elco Center Office lines (CO) 8051 CO1 - CO4 he 8051 connects incoming telco wires to 8 J-45 connectors. (he connectors are wired to the IA 568A standard.) he 8051 has a loop-through on pair 1 for a security system, or Doorel front door intercom. power supply model Standard Cat-5 jumper cables ( foot, foot) Switch on 8051 to bypass Doorel Connect with 4 wires elco In to elco In elco In to elco In elco Out to elco Out elco Out to elco Out CA-5 cables o wallplates located throughout ChannelPlus model Each J-45 jack has its own 8-position 110-type punchdown connector wired to it. he most versatile phone/data systems use structured wiring concepts. he phone/data jacks located throughout the house are each connected to a unique jack on a model 8052 hub. Jumper cables are then used to connect phone, data, or a KSU port to that jack. In this basic system, ordinary telephone service is provided to eight jacks in a house. (o expand, just add another 8051 and 8052 for every eight jacks.)

6 Structured wiring basics: Changing some jacks to data distribution Structured wiring basics: Connecting to a KSU From elco CO1 - CO From elco CO-1 CO J-14 ypical wallplate CA-5 jumper cables Jack 1... CO 1/2 Jack 2... CO 3/4 Jack 3... Ethernet Jack 4... Coax CA-5 cables o wallplates located throughout the house J CA-5 cables o wallplates located throughout the house J Standard J-14 jumper cables (2 pair) CA-5 jumper cables 8052 Ethernet Hub ISDN Jack (from elco) In this example, the house has plain old telephone service (POS) on 3 jacks, ISDN service on another, and an Ethernet network on four other jacks. Jacks can be located throughout the house. Changing from one type of service to another is as simple as moving a jumper cable. Blue White/Blue Orange White/Orange White/ J-11 J-11 J-11 CO 1 CO 2 CO 3 Create this custom cable by cutting off one end of a standard Cat-5 jumper. ypical 3x8 KSU (Panasonic KX-30819)

7 Structured wiring basics: Structured wiring basics: CA 5 wiring techniques Wiring a Cat-5 jack 1 Alternative Ways to Mount the 8050 series hubs. o protect the wiring, the 8050 series hubs should be in a network enclosure. ChannelPlus enclosures allow you to integrate telephone, data, and coax distribution into one convenient location. 110 punchdown tool 2 Keep sheath close to jack. Follow color code for 568A jacks. Position first pair to channel closest to end of jack. (Do not untwist conductor pairs more than 0.5" from the termination point.) Mount on 2600 enclosure... (emove metal bracket from model 8051.) 3 or hang on sheet metal (such as 2602A cabinet)... Using the 110 punch-down tool, push and trim wires into channels and repeat for subsequent pairs. When all conductor pairs are terminated, snap in strain relief caps. Wiring Modular Plug (568A) Insert wires in this order: White/ White/Orange Blue White/Blue Orange White/Brown Brown or mount on 2601 enclosure. Do not untwist more than 0.5"

8 Structured wiring basics: CA 5 Do's and Don'ts Do not allow cable to kink or knot. Also, do not pull the cable with excessive force. Specifications: dimensions WxHxD: " x 1.2" x 1.7" (17.1 cm x 3.1 cm x 4.3 cm) 8052/ " x 1.2" x 2.2" (17.1 cm x 3.1 cm x 5.5 cm) shipping weight: 1 lb (0.45 kg) Warranty When using tie-wraps Bundle the cables loosely. to secure cable, do not cinch cables to where crush-stress is visible. Do not allow cables to form right angles or sharp bends. Use sweeping bends with a minimum radius of 2". Multiplex echnology, Inc. warrants this products to be free from defects in materials and workmanship for a period of one year from the date of purchase or MI will repair, or at its option, replace the defective product. o obtain warranty service, call MI for a return material authorization (MA) number and return the product prepaid to Multiplex echnology, Inc., 3001 Enterprise Street, Brea, CA 92821, Attention: Customer Service. Please put the MA number on the outside of the carton. Any implied warranty arising from the sale of the product including implied warranties of merchantability and fitness for purpose are limited to the warranty stated above. MI shall not be responsible for losses or damages or expenses, whether direct, consequential or incidental arising from the use of or the inability to use this product. Some states do not allow limitations on how long the implied warranty lasts or the exclusion or limitation or incidental or consequential damages, so the above limitations and exclusions may not apply to you. his warranty gives you specific legal rights, and you may have other rights which may vary from state to state. Integrated Home Networks

9 multiplex technology, inc Enterprise Street, Brea, CA , U.S.A * * FAX_ ev A

Enterphone Solo. User/Installation Manual Part No. 421-2001

Enterphone Solo. User/Installation Manual Part No. 421-2001 Enterphone Solo User/Installation Manual Viscount Communication and Control Systems Inc. 4585 Tillicum Street, Burnaby, B.C., Canada V5J 5K9 Phone: (604) 327-9446 Toll Free: 1-800-476-3774 Fax: (604) 327-3859

More information

FITNESS FACILITY WIRING SPECIFICATIONS. NETPULSE Inc. 2331 3rd Street San Francisco, CA 94107 Phone: 415.643.0223

FITNESS FACILITY WIRING SPECIFICATIONS. NETPULSE Inc. 2331 3rd Street San Francisco, CA 94107 Phone: 415.643.0223 FITNESS FACILITY WIRING SPECIFICATIONS NETPULSE Inc. 2331 3rd Street San Francisco, CA 94107 Phone: 415.643.0223 CONTENTS: - Scope of work Summary - Equipment list - Technical specifications - Map of data

More information

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below: Washington University in St. Louis Building: Communication Specification: Research Voice/Network/Typical 1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

More information

Telephone Line Distribution Module

Telephone Line Distribution Module Telephone Line Distribution Module,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, E/-#8 Table of Contents... Introduction....................................................... TLDM Enhancements, Overview & Comparison...........................

More information

PHONE WIRE PHONE JACKS & PHONE PLUGS. Modular plugs are made in three sizes:

PHONE WIRE PHONE JACKS & PHONE PLUGS. Modular plugs are made in three sizes: X PHONE WIRE Each phone line (i.e. each phone number) is an electrical circuit requiring two wires, just like a hi-fi speaker or a light bulb or bicycle horn. In some areas, fiber optics or other new technology

More information

Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4.

Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4. Category 6 Solutions Introduction... 4.2 Cable... 4.3 Patch Panels... 4.4 Modules... 4.6 Patch Cords... 4.12 Outlets... 4.16 Faceplates...4.18 4. 1 Search Category 6 Solutions Introduction ADC KRONE s

More information

Installation Manual For Support Call 01704 807114 or email info@hipentertainment.co.uk

Installation Manual For Support Call 01704 807114 or email info@hipentertainment.co.uk Installation Manual Hip Smart Hub (Standard BT and BT FTTP Sites) The Home Network Hub houses the Home Owner s Broadband Router and connects the hardwired network ports on that Router to three network

More information

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1. USER GUIDE Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator Version 1.3 DM Engineering 2174 Chandler St. Camarillo, CA 91345-4611 805-987-7881 800-249-0487

More information

3 KRONE s 25-Pair FT Block is the perfect replacement

3 KRONE s 25-Pair FT Block is the perfect replacement Section Feed-hru ermination Block System Meets IA/EIA Category 5e (C5e) performance specifications. Appropriate for both data and voice applications. High density and quick installation are the hallmarks

More information

CABLE TERMINATION BEST PRACTICES A guide to improved cable performance through proper termination and installation.

CABLE TERMINATION BEST PRACTICES A guide to improved cable performance through proper termination and installation. B E C A U S E Y O U R B U S I N E S S R U N S T H R O U G H U S CABLE TERMINATION BEST PRACTICES A guide to improved cable performance through proper termination and installation. Outstanding products

More information

Square D Multi-Link Structured Wiring System Increase Your Home s Value and Convenience

Square D Multi-Link Structured Wiring System Increase Your Home s Value and Convenience Square D Multi-Link Structured Wiring System Increase Your Home s Value and Convenience Product Selection Guide Recent technological advances have led to a whole new way of wiring and networking a home,

More information

USB Rover 2850. 2-port USB 1.1 40m Cat 5 Extender. User Guide

USB Rover 2850. 2-port USB 1.1 40m Cat 5 Extender. User Guide USB Rover 2850 2-port USB 1.1 40m Cat 5 Extender User Guide Thank you for purchasing the USB Rover 2850, 2-port USB 1.1 40 m (131 ft) Cat 5 Extender Please read this guide thoroughly. FCC Radio Frequency

More information

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual AT&T PARTNER Plus Door Phone Installation and Operation Manual Copyright 1990 AT&T All Rights Reserved Printed in U.S.A. CIC# 999-500-317 OII722050-051 Issue 1 October 1990 PARTNER Plus Door Phone is a

More information

47611-GB4. Quick-Start Guide 10/100/1000 Mbps 4-Port Gigabit Router IMPORTANT INSTRUCTIONS SAFETY INFORMATION PRE-INSTALLATION CHECKLIST

47611-GB4. Quick-Start Guide 10/100/1000 Mbps 4-Port Gigabit Router IMPORTANT INSTRUCTIONS SAFETY INFORMATION PRE-INSTALLATION CHECKLIST IMPORTANT INSTRUCTIONS 1. Read and understand all instructions. Follow all warnings and instructions marked on the product. 2. Do not use this product near water e.g., near a tub, wash basin, kitchen sink

More information

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT FOR INTELLITOUCH AND EASYTOUCH CONTROL SYSTEMS INSTALLATION GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Technical

More information

Welcome. Digital Phone. Digital Phone. Digital Phone

Welcome. Digital Phone. Digital Phone. Digital Phone Welcome to Welcome to Wi-Power Service Thank you for choosing Wi-Power Internet and Services! This booklet includes important information to better acquaint yourself with Wi- Power Service. Features: Wi-Power

More information

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide Draper Low Voltage, Remote Control, Serial and Network Wiring Guide Copyright 2007 Draper Inc. Form LV-RC-Serial-Network_Wiring07 Print ed in U.S.A. Draper Low Voltage, Remote Control, Serial and Network

More information

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications. Issued 2005/06/01 Section 16743 Data System Page 1 of 7 PART 1 GENERAL 1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications..2 Data system equipment

More information

Catalog 1307532 Issued 8-00

Catalog 1307532 Issued 8-00 Catalog 075 Issued 8-00 Table of Contents Congratulations on purchasing a home featuring the OnQ Home Wiring System! Your home is equipped with an advanced structured wiring system that provides the electronic

More information

3M Quick Connect System (QCS) 2810 Models 2810A and 2810B

3M Quick Connect System (QCS) 2810 Models 2810A and 2810B 3M Quick Connect System (QCS) 2810 Models 2810A and 2810B Instructions October 2010 3 Contents 1.0 General...3 2.0 Recommended Installation Procedure for 3M Quick Connect Systems 2810A and 2810B...3 3.0

More information

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording Hardware & Installation Guide Algo Communication Products Ltd. Customer Support and Sales Tel: 1.877.884.2546 Fax: 604.437.5726 Email: sales@algosolutions.com support@algosolutions.com www.algosolutions.com

More information

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system pool/spa control system ScreenLogic Wireless Connection Kit Installation Guide P/N 520663 - Rev B 8 Technical Support Contact Technical Support at: Sanford, North Carolina (8 A.M. to 5 P.M.) Phone: (800)

More information

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS . HARTING RJ INDUSTRIAL ETHERNET CONNECTORS Ethernet is is coming up to standard industrial interface. Therefore, automation devices such as controllers, sensors and actuators feature possess on one or

More information

Ethernet Cat 5e & Cat 6 Patch Panels

Ethernet Cat 5e & Cat 6 Patch Panels Ethernet Cat e & Cat Patch Panels Copper :: RJ/IDC Models EPPE-CTE & EPPE-CAT User Manual Applys to : EPPE-CTE :: EPPE-CAT Telect, Inc., All Rights Reserved, 9- A0.09.9.000 :: telect.com Ethernet Cat e

More information

QUICK INSTALLATION. 8-Port Telephony Gateway. Model: SPA8000

QUICK INSTALLATION. 8-Port Telephony Gateway. Model: SPA8000 QUICK INSTALLATION 8-Port Telephony Gateway Model: SPA8000 Table of Contents Connect................................................. 4 Regulatory Information....................................12 WEEE

More information

SQUARE D Multi-Link Structured Wiring System

SQUARE D Multi-Link Structured Wiring System SQUARE D Multi-Link Structured Wiring System Class 1400 Schneider Electric Brands Table of Contents Introduction....................................................... 5 Product Description....................................................

More information

e-ask electronic Access Security Keyless-entry

e-ask electronic Access Security Keyless-entry e-ask electronic Access Security Keyless-entry e-fob Keyless-entry entry System Full-Function Function Installation Manual FCC ID: TV2EFOB1 (UM20 ~ 22793-02) Table of Contents Introduction... 1 e-fob Operation

More information

OWNERS MANUAL CONTENTS: Introduction.. 2. Definitions.. 2. Smartwire.. 4. Computing Network 7. Working diagram. 8. Television Antennas 9

OWNERS MANUAL CONTENTS: Introduction.. 2. Definitions.. 2. Smartwire.. 4. Computing Network 7. Working diagram. 8. Television Antennas 9 OWNERS MANUAL CONTENTS: Introduction.. 2 Definitions.. 2 Smartwire.. 4 Computing Network 7 Working diagram. 8 Television Antennas 9 File: Owners Information version: Jan13 1 INTRODUCTION Congratulations

More information

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT Main Power Connections NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT Camlok style "J" series connectors are for connection of up to a 300 Amp 120/240 VAC or 120/208 VAC electrical service. These connections

More information

Part No. P0943133 02. Business Communications Manager 2.5. BIX Box Wiring Guide

Part No. P0943133 02. Business Communications Manager 2.5. BIX Box Wiring Guide Part No. P0943133 02 Business Communications Manager 2.5 BIX Box Wiring Guide 2 Copyright 2001 Nortel Networks All rights reserved. May, 2001. The information in this document is subject to change without

More information

hello. welcome to smart watering.

hello. welcome to smart watering. Quick Start Guide hello. welcome to smart watering. 04 Introduction myblossom.com i m your yard s new brain. let s get started. 06 Contents what s in the box. 1 2 3 4 5 Blossom Controller Blossom Bracket

More information

Terminating 25-Pair Cable and 4-Pair Cross Connects

Terminating 25-Pair Cable and 4-Pair Cross Connects Terminating 25-Pair Cable and 4-Pair Cross Connects Estimated Time: 90 minutes Number of Teams: 2 Number of Team Members: one to four This Lab has four major parts that will be addressed separately. 1.

More information

TAC1 Telephone Entry System Installation and Programming Manual

TAC1 Telephone Entry System Installation and Programming Manual TAC Telephone Entry System 4 7 3 6 8 9 Installation and Programming Manual The Chamberlain Group 84 Larch Ave. Elmhurst, IL 66-96 www.liftmaster.com TABLE OF CONTENTS SPECIFICATIONS 3 Cable Requirements

More information

How To Install A Doorbell Fon Unit

How To Install A Doorbell Fon Unit Doorbell Fon User and Installation Manual Congratulations on purchasing your NEW DoorBell Fon intercom system. This device will provide you with the latest phone intercom system for years to come. It features

More information

Comtrol Cable User Guide

Comtrol Cable User Guide Comtrol Cable User Guide Trademark Notices Comtrol and DeviceMaster are trademarks of Comtrol Corporation. PortVision is a registered trademark of Comtrol Corporation. Microsoft and Windows are registered

More information

Zetron Desktop Microphone Manual 025-9589F

Zetron Desktop Microphone Manual 025-9589F Zetron Desktop Microphone Manual 025-9589F Software License The Zetron software described in this manual is subject to the terms and conditions of Zetron's Software License Agreement, a copy of which is

More information

KVM - DVI, USB 2.0, Cat 5 Extender

KVM - DVI, USB 2.0, Cat 5 Extender KVM - DVI, USB 2.0, Cat 5 Extender 330 feet (100 meters) EL5100 User Guide Powered by Thank you for purchasing the KVM - DVI, USB 2.0, Cat 5 Extender 330 feet (100 meters) Please read this guide thoroughly.

More information

Vertical Phone System Upgrades 2014. Scope of Work

Vertical Phone System Upgrades 2014. Scope of Work Vertical Phone System Upgrades 2014 Scope of Work Project Overview Install new Vertical phone system and phones on site. Complete testing with API helpdesk. Remove old phone system, phones and box up for

More information

Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data

Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data Copyright 2007, American Fibertek, Inc. 0411JD Table of Contents Functional Description...3

More information

CONSOLE REMOTE I /O AC 9V

CONSOLE REMOTE I /O AC 9V CONSOLE CONSOLE REMOTE I /O AC 9V AC 9V REMOTE I /O User Manual CE-220 Read this guide thoroughly and follow the installation and operation procedures carefully in order to prevent any damage to the units

More information

ReadyNet Easy Jack 2 Voice/Data and Data Only Owner s Manual PX-211d and PX-211v

ReadyNet Easy Jack 2 Voice/Data and Data Only Owner s Manual PX-211d and PX-211v ReadyNet Easy Jack 2 Voice/Data and Data Only Owner s Manual PX-211d and PX-211v Phonex Broadband Corporation dba ReadyNet 6952 High Tech Drive Midvale, Utah 84047 801.566.0100 Phone 801.566.0880 Fax www.readynetsolutions.com

More information

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA 02745 USA

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA 02745 USA Thank you for purchasing the Maximum wind speed alarm. The Maximum wind speed alarm is a dual set point wind speed indicator with a two digit LED display. It contains a yellow light to display one set

More information

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide 2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620 Quick Installation Guide Table of Contents Verify The Contents Inside Package Box... 3 Physical Installation... 4 Further Configuration...12 Verify

More information

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL CAUTION: This system is not for use with antenna in raised position while

More information

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX INSTALLATION INSTRUCTIONS Step 1. Determine the position for the Hands-free phone in the elevator phone

More information

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals SSW-iLM Keypad Note: This product is designed to be installed and serviced by security and lock industry professionals Specifications Case dimensions: 6 1/2 L x 1 3/4 W x 1 1/8 D Electrical: 5-12VDC Only

More information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual 5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...

More information

TCB-2 Auto Answer Coupler Product Manual

TCB-2 Auto Answer Coupler Product Manual TCB-2 Auto Answer Coupler Product Manual About Comrex Comrex has been building reliable, high quality broadcast equipment since 1961. Our products are used daily in every part of the world by networks,

More information

E Series. E Series. Category 6 and 5e. Features

E Series. E Series. Category 6 and 5e. Features E Series Category 6 and 5e CommScope, world leader in copper and fiber connectivity, offers the E Series product line as the ideal solution to all your infrastructure needs for safe and reliable data transmission.

More information

I Click on a link tab to jump to that page. Cover Page

I Click on a link tab to jump to that page. Cover Page Publication, Duplication, or Retransmission Of This Document Not Expressly Authorized n Writing By The nstall Doctor s Prohibited. Protected By U.S. Copyright Laws. 1997,1998,1999,2000. Factory Radio Other

More information

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. Power Max Level 2 Charging Station en Installation and Operating Instructions This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the

More information

ChargePoint Home. Installation Guide. ATTENTION: Please read thoroughly and keep this installation guide.

ChargePoint Home. Installation Guide. ATTENTION: Please read thoroughly and keep this installation guide. ChargePoint Home Installation Guide ATTENTION: Please read thoroughly and keep this installation guide. Contents Meet ChargePoint Home... 3 Setup and Installation... 4 For Professional Electricians...

More information

BroadBand PowerShield. User Manual

BroadBand PowerShield. User Manual BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains

More information

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories 2015 PRODUCT CATALOG 2ND EDITION LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories A technically and commercially

More information

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &

More information

LIEBERT VNSA Installation Sheet

LIEBERT VNSA Installation Sheet LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display

More information

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com 1080P Extender for HDMI over one CAT5 GTV-HDBT-CAT5 User Manual gefentv.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours:

More information

Cable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range

Cable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range HONEYWELL SECURITY & CUSTOM ELECTRONICS Cable Products Honeywell's Genesis Series provides a full range of low voltage cables for security, fire, sound, voice and data, video, structured cabling and other

More information

Category 6 UTP - Cabling System

Category 6 UTP - Cabling System AMP NETCONNECT Category 6 UTP Cabling System...... real Category 6 Performance, both on Component as well as on System level! Owing to the extreme high performance of the AMP NETCONNECT Category 6 UTP

More information

ATTACHMENT F 050R6800016 - CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6

ATTACHMENT F 050R6800016 - CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6 050R6800016 CABLE AND WIRING SERVICES (Column A) (Column B) (Column C) (Column D) (Column E) (Column F) (Column G) (B+C+D+E)*F= G Item Description PER 100' RUN PER 150' RUN PER 200' RUN PER 300' RUN QUANTITY

More information

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input

More information

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI Technical Manual For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI Caller ID.com WHOZZ CALLING? POS 2 Caller ID Monitoring Unit Technical Manual For use with Caller ID signaling

More information

Color Mark Sensor with Red or Green LED E3S-VS

Color Mark Sensor with Red or Green LED E3S-VS Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical

More information

Mounting Plate / Screwdriver. Alignment Stickers Screws / Desiccant Bag / Double-sided Tape / Rubber Seal Plug / Rubber Washer

Mounting Plate / Screwdriver. Alignment Stickers Screws / Desiccant Bag / Double-sided Tape / Rubber Seal Plug / Rubber Washer 5000020G Warning Before Installation English Power off the Network Camera as soon as smoke or unusual odors are detected. Do not place the Network Camera on unsteady surfaces. Do not insert sharp or tiny

More information

Table of Contents. www.hunterfan.com. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Table of Contents. www.hunterfan.com. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing. www.hunterfan.com Table of Contents What to Expect with Your Installation 30 inches Hanging the Fan Wiring 8 Maintenance, Operation & Cleaning Light Kit 13??? 14 1 9 Troubleshooting 11 5 Blades Motor Housing

More information

PC Tab INSTALLATION MANUAL SECURE-IT, INC. EAST LONGMEADOW, MA 01028. 800-451-7592 / 413-525-7039 (fax) 413-525-8807 http://www.secure-it.

PC Tab INSTALLATION MANUAL SECURE-IT, INC. EAST LONGMEADOW, MA 01028. 800-451-7592 / 413-525-7039 (fax) 413-525-8807 http://www.secure-it. PC Tab INSTALLATION MANUAL SECURE-IT, INC. EAST LONGMEADOW, MA 01028 800-451-7592 / 413-525-7039 (fax) 413-525-8807 http://www.secure-it.com IMPORTANT READ ENTIRE MANUAL BEFORE STARTING!!! System Overview

More information

Advantium 2 Plus Alarm

Advantium 2 Plus Alarm ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia

More information

Lightning Protection Guide. PTP 400 and 600 SERIES

Lightning Protection Guide. PTP 400 and 600 SERIES Technical Note Lightning Protection Guide MOTOROLA POINT-TO-POINT BROADBAND WIRELESS SOLUTIONS MOTOROLA PTP 400 and 600 SERIES WIRELESS ETHERNET BRIDGES Table of Contents Introduction.... 3 Recommended

More information

TELEPHONE CABLING TECHNOLOGY INFINITY CABLING

TELEPHONE CABLING TECHNOLOGY INFINITY CABLING TELEPHONE CABLING TECHNOLOGY Main Types Outdoor Voice Grade Telephone Cable Heavy Duty Type, Weatherproof, Sun Protected, Mechanical protection from damage. Some types can be buried in the ground. Cable

More information

Take-2 by Nel-Tech Labs, Inc. Installation & User Manual

Take-2 by Nel-Tech Labs, Inc. Installation & User Manual Take-2 by Nel-Tech Labs, Inc. Installation & User Manual Index: Introduction... 3 Take-2 Layout Summary... Installation... 4 5-6 Warranty & FCC... 7 Introduction: The Take-2 is a state-of-the-art message-on-hold

More information

Innovative DOOR STATION Solutions

Innovative DOOR STATION Solutions Innovative DOOR STATION Solutions When a visitor arrives at your front door or gate we ring... Your mobile when you are out Your normal telephones in your home Your PABX system in your office Communicating

More information

Testing, Repairing & Installing Home Telephone Wiring Disclaimer

Testing, Repairing & Installing Home Telephone Wiring Disclaimer Testing, Repairing & Installing Home Telephone Wiring Disclaimer This information is intended to assist customers of telephone service to understand the telephone wiring in their home. This information,

More information

=============================== WARNING

=============================== WARNING =============================== WARNING EXPLANATION OF GRAPHICAL SYMBOLS This symbol is intended to alert the user to the presence of unprotected dangerous voltage" within the product's enclosure that

More information

Model SRMD Setra Remote Monitoring Display

Model SRMD Setra Remote Monitoring Display Model SRMD Setra Remote Monitoring Display 1.0 GENERAL INFORMATION Thank you for purchasing the Setra Remote Monitoring Display (SRMD). The SRMD is a digital panel meter with a bright 1 LED display for

More information

16/32 Channel 1U Rack Mount CCTV Power Supply

16/32 Channel 1U Rack Mount CCTV Power Supply 16/32 Channel 1U Rack Mount CCTV Power Supply Manual PH-A3224-GUQ Shown 16-Channel 32-Channel PTC PH-A1612-PUQ PH-A3224-PUQ Glass Fuse PH-A1612-GUQ PH-A3224-GUQ Industrial design 12 Amp 3 Amps per channel

More information

Anthro Tablet Charging Cabinets

Anthro Tablet Charging Cabinets Owner's Manual for Anthro Tablet Charging Cabinets Covers part numbers beginning TAB16 and TAB20. Components at a Glance The open views of the front and side of the cabinet below are for the TAB20 cabinet.

More information

Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide

Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT Active Speaker System with remote input LX523 User Manual & Installation Guide AUDAC PROFESSIONAL AUDIO EQUIPMENT User Manual & Installation

More information

GSD 22 Sounder Module. installation instructions

GSD 22 Sounder Module. installation instructions GSD 22 Sounder Module installation instructions Copyright 2006 Garmin Ltd. or its subsidiaries Garmin International, Inc. 1200 East 151 st Street, Olathe, Kansas 66062, USA Tel. (913) 397.8200 or (800)

More information

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4 user s manual model #: SPB3200 Charger for Samsung Galaxy S 4 What s Included Unpack the battery case and make sure all accessories are put aside so they will not be lost. hello. USB to Micro USB Cable

More information

A Remodeler's Guide to: Communications Wiring for Today's New Homes

A Remodeler's Guide to: Communications Wiring for Today's New Homes A Remodeler's Guide to: Communications Wiring for Today's New Homes Page 1 of Copper for Telecommunications Electrical Energy Efficiency A Remodeler's Guide to: COMMUNICATIONS WIRING FOR TODAY'S HOMES

More information

Product Manual. Precision Inbound Call Routing Fast Outbound Line Hunting Streamlined Telecommunications

Product Manual. Precision Inbound Call Routing Fast Outbound Line Hunting Streamlined Telecommunications MJNOVIS Expanding Communications Product Manual Precision Inbound Call Routing Fast Outbound Line Hunting Streamlined Telecommunications 1 LINE 2 3 4 1 2 3 4 5 6 7 8 9 10 11 12 LINE 2 LINE 3 LINE 4 MULTI-LINK

More information

T-Extender E-Extender

T-Extender E-Extender T-Extender E-Extender TABLE OF CONTENTS SECTION - DESCRIPTION... SECTION - SPECIFICATIONS...3 SECTION 3 - INSTALLATION... SECTION - FRONT PANEL INDICATORS...7 SECTION - INTERFACE SIGNALS AND CABLES...8

More information

A guide to connecting to fibre optic networks for homeowners, architects, builders and developers.

A guide to connecting to fibre optic networks for homeowners, architects, builders and developers. A guide to connecting to fibre optic networks for homeowners, architects, builders and developers. Chorus is New Zealand s largest telecommunications utility company. We maintain and build the local access

More information

How to check for Sync at the NID

How to check for Sync at the NID How to check for Sync at the NID In order for your DSL service to work properly, your DSL modem must receive a clear DSL signal from the phone company s central office (CO). When the DSL modem and the

More information

Expanding a 40-Type Cabinet

Expanding a 40-Type Cabinet Expanding a 40-Type Cabinet using the 3M Add-On Terminal 4220P 400-Pair and Jumper Trough Instructions January 2006 Table of Contents 1.0 General... 3 2.0 Cabinet Overall Descriptions... 3 3.0 Tools Required...

More information

USER MANUAL QUATTRO 3 CONFERENCE SPEAKERPHONE MODEL 302

USER MANUAL QUATTRO 3 CONFERENCE SPEAKERPHONE MODEL 302 USER MANUAL QUATTRO 3 CONFERENCE SPEAKERPHONE MODEL 302 QUATTRO3 OVERVIEW Dial Pad 4 Microphone Array L1 Function L2 Function Power/Mute Volume Down Volume Up The Quattro3 (Q3) is a high-quality conference

More information

How To Service A Paper Shredder

How To Service A Paper Shredder Paper shredder 20-2HS 80C POWERSHRED OPERATING INSTRUCTIONS NOTICE D'UTILISATION MANUAL DEL PROPIETARIO BETRIEBSANLEITUNG 20 80 20C 80C 20-2HS Edition 0/0.70.999.0 Edition 0/0 20-2HS 80C Paper shredder

More information

Operation and Installation Manual

Operation and Installation Manual Operation and Installation Manual RCM-10 Remote Control Monitor and RSM-10 Remote Status Monitor for the CNA-100 & CNA-200 Automations Revision 1.1 9/98 WARRANTY INFORMATION The RCM-10 Remote Control

More information

16-Port and 24-Port 10/100 Switches

16-Port and 24-Port 10/100 Switches 16-Port and 24-Port 10/100 Switches Use this guide to install the following products: SR216 SR224 16-Port 10/100 Switch 24-Port 10/100 Switch User Guide COPYRIGHT & TRADEMARKS Specifications are subject

More information

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector

More information

Network Cabling Guide

Network Cabling Guide Network Cabling Guide Poor or incorrectly installed network cabling can cause numerous problems with your computer network. Whilst we recommend that you employ a network / cabling specialist to wire and

More information

TCTC Cabling Specifications

TCTC Cabling Specifications TCTC Cabling Specifications Purpose: To provide a standard specification that will be used for all Tri County Technical College (TCTC) facilities requiring structured cabling installation. Product specifications,

More information

ANT1750F Multi-Directional Slim Digital Antenna / Antena multidireccional plana para interiores / Antenne numérique mince multidirectionnelle

ANT1750F Multi-Directional Slim Digital Antenna / Antena multidireccional plana para interiores / Antenne numérique mince multidirectionnelle Multi-Directional Slim Digital Antenna / Antena multidireccional plana para interiores / Antenne numérique mince multidirectionnelle User s Guide / Guía del Usuario / Guide de l utilisateur FCC Statement

More information

How To Set Up A Minipatch System For A Small Office Or Home Use

How To Set Up A Minipatch System For A Small Office Or Home Use Issue : 4 Wood Communications Networking Products Catalogue Small Office & Home Solution Small Office / Home Solution Min LAN Comms Cabinets - Multimedia Panel - Soho Ethernet Switches - Multiroom Audio/Video,

More information

This Document Contains:

This Document Contains: Instructional Documents Video Conference >> PolyCom >> VSX 7000 Extension Computing Technology Unit This Document Contains: A Device Description An Installation Guide Instructions for Use Best Practices

More information

Cat7/Class F New Installation Concept New infrastructure. Handbook

Cat7/Class F New Installation Concept New infrastructure. Handbook Cat7/Class F New Installation Concept New infrastructure Handbook contents 1 Introduction 3 2 What is the Cat7/Class F installation concept 3 3 Distribution centre 3 3.1 Patch Modules 3 4 How to handle

More information

Ethernet Patch Cord Wiring

Ethernet Patch Cord Wiring Ethernet Patch Cord Wiring C ONTENTS Ethernet Patch Cords & RJ-45 Connectors... 2 Ethernet Patch Cords and UTP Cabling... 3 What s all the twisting about?... 4 Ethernet Applications... 5 568A & 568B Wiring

More information

Christopher Rathgeb ECE 453 Dr. Qi 9/19/2006. Task 1: Make an Ethernet cable yourself.

Christopher Rathgeb ECE 453 Dr. Qi 9/19/2006. Task 1: Make an Ethernet cable yourself. Task 1: Make an Ethernet cable yourself. Christopher Rathgeb ECE 453 Dr. Qi 9/19/2006 You are required to make the cable within 20-minute period of time in FH422 (the networking lab). The TA will be there

More information

Juice Box Stages 1&2 135&335 Installation Guide 5/10/08

Juice Box Stages 1&2 135&335 Installation Guide 5/10/08 Tools Required: 8mm socket or nut driver Small flat head screwdriver Electrical tape, masking tape, or shrink tube Pep talk: Although the install looks daunting at first, once you get the learning curve

More information

Terayon DOCSIS Modem Installation. Guide

Terayon DOCSIS Modem Installation. Guide Terayon DOCSIS Modem Installation Model: TJ 700 Series Modem Guide Power Cable PC Data Test 4988 Great America Parkway Santa Clara, CA 95054 www.terayon.com 8500229 Rev A Table of Contents Table of Contents

More information