KLEIN UTILITY TOOLS & MISC.
|
|
- Cameron Miller
- 7 years ago
- Views:
Transcription
1 July 2015 Utilities
2 2
3 Contents Chicago Grips Parallel Jaw Grips Haven Grips Cable Tensioning Tools Tool Pouches Canvas Buckets Voltage Detectors Wrenches Information, Care and Maintenance
4 Grips CHICAGO GRIPS Hamer Klein KE Cable Application Jaw Shape Cable Specifications External Ø Range (inches) External Ø Range (mm) Max Safe Load (kg) KE Copper (stranded) or aluminium ACSR Ο KE KE KE K Extra high-strength cables or guy KE strands KE K PVC covered Ο K conductor KE Small bare cables PARALLEL JAW GRIPS Hamer Klein Cable Application Jaw Shape Cable Specifications External Ø Range (inches) External Ø Range (mm) Max Safe Load (kg) K PVC covered Ο KE400 * or bare cable * Available on request only HAVEN GRIPS * Hamer Klein Cable Application External Ø Range (inches) Cable Specifications External Ø Range (mm) Max Safe Load (kg) KE Steel strand KE Wire rope * Use where conductor damage is not a factor. 4
5 CABLE TENSIONING TOOLS Hamer Klein Description KE N Howe wire tool, 25mm nylon webbing strap with swivel hook 227 Kg max safe load KE1350 KN1500P-EX Web-strap ratchet hoist 680 to 1361 Kg max load rating K90 KE490 H S H S SR Block & tackle (supplied with 259 swivel anchor hook, block with guarded snap hooks, 25 rope & block with guarded snap hook with eye for rope tie-off ) Block & tackle (supplied with 259 swivel anchor hook, block with guarded snap hooks & block with guarded snap hook with 25 spliced rope attached to eye) KE110 K90 KE1350 5
6 TOOL POUCHES Hamer Klein KL KL Description 8 pocket tool pouch made from soft, pliable white leather. Riveted and stitched for extra durability. Tunnel loop belt connection. Belt width 64mm, overall size 279mm x 254mm. 11 pocket tool pouch, made from soft, pliable leather. Moisture resistant, riveted and stitched. Slotted belt connection. Belt width 70mm, overall size 254 mm x 267mm. KL4985 CANVAS BUCKETS WITH POLYPROPELENE BOTTOMS KL4990 Hamer Klein Description KE #6 Canvas Tapered Wall 305mm Ø to 229mm Ø x 330mm H KE5113S 5113S #6 Canvas Tapered Wall with Swivel Snap 305mm Ø to 229mm Ø x 330mm H KE5103S 5103S #4 HD Canvas Tapered Wall with Swivel Snap 305mm to 229mm Ø x 330mm H KE5109S KE5109PS 5109S 5109PS #6 Canvas Wide-Opening Straight-Wall with Swivel Snap 305mm Ø x 381mm H Load rated to 34Kg max #6 Canvas Wide-Opening Straight-Wall 1 Int. Pocket with Swivel Snap 305mm Ø x 381mm H Load rated to 34Kg max KE5171PS 5171PS #4 HD Canvas Tapered Wall 305mm to 229mm Ø x 305mm H & 4 Ext. Pockets KE5172PS 5172PS #4 HD Canvas Tapered Wall 305mm to 229mm Ø x 305mm H & 15 Int. Pockets KE5113 KE5103S KE5171PS KE5172PS Canvas Weights Info. 1 = Thickest, 8 = Thinnest KE5109S 6
7 VOLTAGE DETECTOR Hamer PET4000 Description V-Watch Personal Voltage Detector VW-20H with carry case Worn on the outside of your clothing at mid-torso, the V-Watch provides that extra level of safety by detecting and alerting you to the presence of electrical fields or energized electrical equipment. In emergencies, you and your crews can move safely to quickly restore power to your customers. The V-Watch comes in a tough nylon carrying case lanyard that is worn around the neck during use. The C-10 Carrying Case Lanyard is made with a black shielded material. Features and Benefits Alerts user to proximity of high voltage Audible and visual alarms increase in frequency the closer the user gets to energized equipment Typical V-Watch initial warning distance is about 7 feet (2.13 m) from a 4kVAC conductor (see instruction manual for more details). Warning distance increases with higher voltages. Provides another level of safety for line crews, storm restoration workers and first responders Low battery indicator Field replaceable 9V battery Rugged protective housing Built-in self test Lightweight Carrying case lanyard Black shielded nylon material Electrically shielded Storage case when the V-Watch is not in use Lanyard allows user to adjust to optimum mid-torso position Comes supplied with the black C-10 carry case pictured. Specifications Sensitivity: Factory Set at 50/60 Hertz sensing threshold (first beep). The V-Watch will only detect AC voltage. Do not use below 2400 Volts line-to-ground. Typical Warning Distance: About 7 feet (2.13 m.) from a 4kV (2.4kV line-to-ground) AC conductor. Operating Temperature: -20 to +120 F (-29 to 49 C) Operating Frequency: 50Hz/60Hz Battery: 9V alkaline 1604A, IEC 6LR61. Life is 2 years in storage, 1 year typical usage. Beeper Sound Pressure Level: 100 decibels Water Withstand: Protected from falling rain per IEC-529, Level 2 Weight (with battery): 5.2 oz. (147 g.) Dimensions: 3.5 x 2.88 x 1.25 (8.89 cm. x 7.32 cm. x 3.18 cm.) Voltage Range: 2400VAC line-to-ground and above MODIEWARK Hamer MWB0033 MWB0022 Description The Modiewark detects the presence of an alternating electric field. Its unique switching action allows identification of A.C. voltage levels from 110v to 330,000 volts. Also available on request: VRS Modiewark version capable of testing 240V, 1KV, 2.2KV, 6.6KV, 11KV and 22KV MWB0011 Modiwark Sunrise Replacement Handle MWB MWB0033
8 Podgy Ratchet Wrench Hamer Description Sizes 18mm PET1317 Ratchet Wrench 13mm / 17mm PET1824 Ratchet Wrench 18mm / 24mm PET1924 Ratchet Wrench 19mm / 24mm 24mm (other side) Other sizes available on indent order: Hamer Description Sizes PET1921 Ratchet Wrench 19mm / 21mm PET2124 Ratchet Wrench 21mm / 24mm PET2430 Ratchet Wrench 24mm / 30mm Ratcheting Construction Wrench Hamer Supplier Description KL /2" square drive Ratcheting Wrench Adj. Construction Wrench Hamer Supplier Description KL Adjustable-head Construction wrench Max size capacity 38mm 8
9 FORGED STEEL GRIPS Klein Chicago and Haven Grips are used to pull wire and cable, and to maintain temporary tension until the cable can be permanently terminated. These grips are not to be used as anchors. Klein Chicago grips have locking loop handles, standard on most grips that allow the jaws to be held in an open position for easier placement on wire or cable. This saves substantial time, and makes grip positioning easier than with wedge or bolt-on designs. To lock, open the jaws and fold loop handle toward the side plates. HOW TO SELECT THE PROPER GRIP Three basic factors determine the selection of the proper grip for each specific application: Type of wire or cable. Outside diameter of wire or cable. Maximum safe load required. Also the correct type of inside jaw contour should be considered. It is essential to select the correct gripping jaws to avoid damage to the wire or cable. When pulling stranded wire, the jaws should be long enough to take a full lay of cable to avoid damage to the conductor. Inside-Jaw Contours: Each grip comes with one of three inside-jaw contours appropriate for the type of wire or cable to be worked. Single V: Simple three-point contact jaws are designed for use on small-diameter bare wire and cable (solid stranded). Double V: Four-point contact provides greater gripping pressure and assures proper alignment of wire and cable within the jaws. Designed for high-strength steel guy wire and messenger wire, and extrahigh-strength cables and conductors. Round: Round jaws provide maximum contact and gripping power to minimize conductor damage. This jaw design is recommended for use on bare aluminium, ACSR, and copper conductors. REPAIR OR REPLACE? Never repair any grip. Grip jaws can sometimes be replaced if the grip is returned to Klein, but structural wear or damage cannot be safely corrected. Grips that are bent, misaligned or otherwise distorted should be discarded and replaced. Before each use, check all grips for jaw condition, proper alignment of jaws and all parts, and possible distortion caused by exceeding safe-load specifications. Grips should operate smoothly. Spring-loaded grips should lock open with loop handle in Down position and should close automatically with loop handle Up. The Klein parallel jaw grip may be tested by opening and closing the jaws by hand, while exercising proper caution. All parts and rivets, which may be distorted due to exceeding safe load, should be checked. RECOMMENDED CARE & MAINTENANCE The following guidelines have been established in order to maintain all grips in good condition: Clean the Grip Jaws Use emery cloth or a clean wire brush to periodically clean the surfaces of grip jaws. (Note: Aluminium-strand conductors may have a die-grease coating, which can deposit on grip jaws. New aluminium conductors should be wiped clean before grip application. Grip jaws should be wiped clean of all grease before use.) Be sure to clean grip jaws before and after each use on wire or cable, which has been galvanized or otherwise coated. Clean All Working Parts Use Klein s Cinch Cleaner/Degreaser Cat. No to clean all joints and moving parts then apply Cinch Yellow No Check All Parts Look carefully for distortion or misalignment. Never Repair Any Grip If there is ever any question about the safe condition of any grip, please consult us directly. Please remember this rule. 9
10 10
758 Heavy-duty Ratchet Guy Wire Cutter
INSTRUCTION MANUAL 758 Heavy-duty Ratchet Guy Wire Cutter Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register this product
More informationCutting and stripping tools
Cutting and stripping tools Introduction 2 Cutting and stripping tool 0.02-10 mm² (16 mm²) 3 Stripping tool for cables Ø 2.5-40 mm 4 Tools for cutting and stripping of conductors 0.5-6 mm² and for cutting
More informationPART 1 - INTRODUCTION...
Table of Contents PART 1 - INTRODUCTION... 3 1.1 General... 3 1.2 Sensor Features... 3 1.3 Sensor Specifications (CDE-45P)... 4 Figure 1-1 CDE-45P Sensor Dimensions (standard, convertible style)... 4 PART
More informationApplication Tooling Specification Sheet
Modular Crimp Head Order No. 63825-2170 Application Tooling Specification Sheet TYPE 4A Hand Crimp Tool Order No. 63825-2100 FEATURES % A full cycle ratcheting hand tool ensures complete crimps % Ergonomically
More information162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL
162 CB CABLE TRACER Filter Probe & Tone Generator INSTRUCTION MANUAL INDEX PAGE 1. INTRODUCTION... 1 2. FILTER PROBE... 1-3 3. TONE GENERATOR... 3-6 4. SPECIFICATION... 7-8 5. MAINTENANCE... 8 1. INTRODUCTION
More informationwww.huskietools.com 71
www.huskietools.com 71 S-Series Hydraulic Handheld Cutters P. 75 Ratchet Cable Cutters P. 73 Low Pressure Cable Cutter P. 79 SP-Series Hydraulic Handheld Cutter Heads P. 77 Cable and Insulation Strippers
More informationReasons for reissue of this instruction sheet are provided in Section 5, REVISION SUMMARY.
Reasons for reissue of this instruction sheet are provided in Section 5, REVISION SUMMARY. Air Pressure 586.1 min 689.5 kpa max [85 min 100 psi max] Air Displacement 721,000 mm 3 [44 in. 3 ] Figure 1 Weight
More informationWire Pulling Grips. Wire Pulling Grips
Wire Pulling Grips Wire pulling grips from Klein combine strength and durability to lead the world in creating an extremely highquality line of grips. With ease-of-use and lasting quality, Klein wire-pulling
More informationArmor Rods. Armor Rods NOMENCLATURE GENERAL RECOMMENDATIONS
Armor s Transmission: Section 1 NOMENCLATURE Armor s Single Support and Double Support : Identified by S and D appearing in the length column on the catalog page. Should the maximum distance between tied
More informationPressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
More informationOSHA 1910.66 Remove impacted systems and components. Inspect systems prior to use.
Q: When do I remove my harness from service? A: ANSI (American National Standards Institute) A10.32-2004 states the service life of fall protection equipment manufactured of synthetic fiber shall be 5
More informationRAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo
Connectors, Clamps, Compensating Devices, Insulators and Safety Equipment for Overhead Catenary Lines RAILWAY CATENARY SYSTEMS Components and Systems for the Electrification of Railway Lines. Welcome to
More informationHorizontal Lifeline. SideWalk Rope. User Instructions. 3M Occupational Health and Environmental Safety. Fall Protection Equipment
3M Occupational Health and Environmental Safety Fall Protection Equipment SideWalk Rope Horizontal Lifeline User Instructions User Instructions for the 3M TM Side Walk 2-Man Rope Horizontal Lifeline System.
More informationShunt lock function 3066
Version: January 2004 Contents Alarm System Activation unit Deactivation unit Digital locking cylinder or Smart Relay 1.0 Method of Operation 4 1.1 General 4 1.2 Turning the Alarm System On 4 1.3 Turning
More informationSuper Slider ADJUSTABLE FROM 3.5-12 Model #HD26229
Super Slider ADJUSTABLE FROM 3.5-12 Model #HD26229 IMPORTANT!!! ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH. USERS
More informationSAFE HANDLING OF PRECAST CONCRETE PRODUCTS
SAFE HANDLING OF PRECAST CONCRETE PRODUCTS Safety Handling of Precast Concrete Products The lifting of any precast product requires the use of special equipment and substantial planning and knowledge.
More information5-Other arc welding WELDING TOOLS AND ACCESSORIES
WELDING TOOLS AND ACCESSORIES -Other arc welding ARC WELDING OTHER Cables and connectors... 80 to 81 Clamps... 82 to 83 Magnetic ground clamps... 84 to 8 Hammers / brushes... 86 Miscellaneous... 87 Accessories...
More informationVERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # HD26249
VERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # HD26249 IMPORTANT!!! ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS
More information5.2. Overview. The better method to install solderless compression connectors on power cable
5.2 Overview The better method to install solderless compression connectors on power cable The Thomas & Betts method of installing compression connectors on power cables is designed to provide a high degree
More informationUser Instruction Manual Vertical Lifelines and Vertical Lifeline Subsystems
Instructions for the following series products: User Instruction Manual Vertical Lifelines and Vertical Lifeline Subsystems Vertical Lifelines Vertical Lifeline Subsystems (See back pages for specific
More informationGUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables
Engineering Department SEPTEMBER, 2007 GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables General Requirements This section applies to all public and private utilities,
More informationUT202A Operating Manual. Contents
Title Contents Page Overview Unpacking Inspection Safety Information Rules for Safe Operation International Electrical Symbols The Meter Structure Functional Buttons and auto power off Display Symbols
More informationUsing Klein Tools Chicago Grips in Common Overhead Applications
Using Klein Tools Chicago Grips in Common Overhead Applications USING KLEIN TOOLS CHICAGO GRIPS IN COMMON OVERHEAD APPLICATIONS Materials Used: Klein Tools Chicago Grips, Klein Tools KN1500PEX web strap
More informationVoltage Detection and Indication by Electric Field Measurement
Voltage Detection and Indication by Electric Field Measurement William McNulty, P.E. Technical Director Voltage Detection and Indication by Electric Field Measurement William McNulty, P.E. HD Electric
More information3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE
4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement
More informationElectrical Safety Products
Electrical Safety Products Trelleborg Electrical Safety Products A safe working environment is important in all industries, but in the electrical generation and supply industry, it is paramount. Trelleborg
More informationRAUFOSS EXPLOSIVE COMPRESSION FITTINGS
INSTRUCTION MANUAL FOR RAUFOSS EXPLOSIVE COMPRESSION FITTINGS Box 7 2831 Raufoss Norway Tlf.: +47 61 15 17 87 Fax: +47 61 15 25 56 25 January 2013, rev 2 Available on www.vpmetall.no Page 1 CONTENTS GENERAL
More informationThe load carrier system designed for professionals
The load carrier system designed for professionals THULE PROFESSIONAL The rugged time-saving system Thule Professional is a load carrier system from the world leader in utility transportation. Every aspect
More informationPower Supply Cables and Connectors
Power Supply Cables and Connectors Often during the excitement of designing a challenging new system, some of the more mundane engineering aspects get overlooked. This is especially true of connections
More informationMESSENGERS FOR AERIAL CABLE
MESSENGERS FOR AERIAL CABLE COPPERWELD - EHS, 30% CONDUCTIVITY MES(size)CUWELD Size O.D. Stranding Breaking Strength Wgt./Mft. MES1/4CUWELD 1/4".242 7 #12 5,783 lbs. 128 MES5/16CUWELD 5/16".306 7 # 10
More informationLiftAlloy Chain Slings
CHAIN SLING BASICS Slings Lift-All chain slings meet or exceed all OSHA, ASME B30.9 and NACM standards and regulations. chain slings, available in 80 for 7/32" and 7/8"- /4" and 00 for 9/32"-3/4", are
More informationDigital Ground Resistance Tester. Models 4620 & 4630. Digital Ground Resistance Tester
Digital Ground Resistance Tester Models 4620 & 4630 Digital Ground Resistance Tester Models 4620 and 4630 perform both ground resistance and soil resistivity tests. These testers measure from 0 to 2000Ω,
More informationMCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
More informationTENSIONMETER ** code 183_LNRSTW **
Electronic tension meter for applications in textile and wire industry. 9 Tension ranges from 0.1-200 cn to 5-50 dan. Versatile instruments usable for applications in textile industry: e. g. 50 up to max.
More information12 Volt 30 Amp Digital Solar Charge Controller
12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
More informationARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013 READ CAREFULLY These instructions are intended to cover good practices in
More informationHow To Read A Pipe From A Sensor
Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing
More informationWire Pulling Grips. Wire Pulling Grips. F o r P. r o f e. s s i o. n a l s. .. S i. n c e 1
Wire Pulling Grips F o r P r o f e Wire pulling grips from Klein combine strength and durability to lead the world in creating an extremely highquality line of grips. With ease-of-use and lasting quality,
More informationProtection Systems. A UTC Fire & Security Company F-73-01. Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS
Effective: May 2007 AlarmLine TM R Protection Systems Linear Heat Detector A UTC Fire & Security Company F-73-01 FEATURES Integrating Type Linear Heat Detector Analog Sensing Field Adjustable Alarm Set
More informationThe Campbell operation facilities in York, PA, and Cortland, NY, conform to Quality Standard ISO 9001.
Campbell Blocks Table of Contents Begun as a forging company in 1834, Campbell/Brewer-Titchener first manufactured horse harnesses, then carriage hardware, then horseless carriage hardware. From hardware
More informationWorking at Heights and Fall Protection
Standard Operating Procedures Working at Heights and Fall Protection Last Modified: JAN 2013 1 of 6 Working at Heights and Fall Protection I Purpose Serious accidents can result from falls. All employees
More informationBAGGAGE HANDLING SYSTEMS. Trastecnica S.p.A. Handling Baggage Systems Edition 2002 - Rev. 00-1 -
BAGGAGE HANDLING SYSTEMS Trastecnica S.p.A. Handling Baggage Systems Edition 2002 - Rev. 00-1 - TECHNICAL SPECIFICS INDEX Check-in with one conveyor 4 Scales 6 Belt Conveyors 8 Take away 9 Feeder and Belt
More informationWire Rope Extender Lanyard
Reliance Industries, LLC User Instructions for Wire Rope Extender Lanyard Model # 714004 Reliance Industries, LLC PO Box 140008 Denver, CO 80214 Ph. (800) 488-5751 Ph. (303) 424-8650 Fax (303) 424-8670
More informationEnglish. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...
2 Contents Components Attachments Guidance Installation Operation Maintenance Service Technical Troubleshooting Symbols used to mark instructions...3 Included Attachments...4 Congratulations...5 Getting
More informationSECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
More informationHAND CRIMP TOOL Specification Sheet Order No. 63819-0900
HAND CRIMP TOOL Specification Sheet Order No. 63819-0900 FEATURES TYPE 4D Œ A full cycle ratcheting hand tool ensures complete crimps Œ Ergonomic soft grip handles for comfortable crimping Œ A precision
More informationBUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE
BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE Toll Free Telephone Numbers Residential Services 800.454.3853 Commercial Services 800.653.5307 Utility Locating Company N.C. 800.632.4949 S.C. 888.721.7877
More informationOPERATING INSTRUCTIONS
GB OPERATING INSTRUCTIONS Automatic Wedge Welding Machine Please read operating instructions carefully before use and keep for further reference. APPLICATION The is an automatic wedge welding machine for
More informationACL 395 Resistivity Meter
ACL 395 Resistivity Meter OPERATION MANUAL Meter is warranted for one year from the date of purchase on parts and labor. Calibration is recommended every 12 months. 840 W. 49 th Place Page 1 of 13 info@aclstaticide.com
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration
More informationSTEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13
STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13 (See Supplemental Instructions for trailers with heavy duty round footplates and/or Power Leveling Systems) PHONE SUPPORT
More informationIMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.
THERMAWAVE CERAMIC HEATER Model HZ-850 Series Model HZ-860 Series IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. Warning Failure to
More informationNow Available through:
Now Available through: Adhesive- Mount s s Perma Dome Packages Perma Plate Packages Mini Plate Packages Convenience. Support. Security. The PC Guardian ADVANTAGE Flexible and expandable adhesive-mount
More informationTECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR
TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR 1.1.0 SCOPE : This specification covers design, manufacture, testing at manufacture s works before
More informationEMPLOYEE FALL PROTECTION
EMPLOYEE FALL PROTECTION You can fall from any height and be seriously injured or killed. In the construction industry, as well as any other industry, when falls from heights happen, they are usually very
More informationImplosive Connectors. for overhead transmission lines
Implosive Connectors Implosive Connectors for overhead transmission lines VP metall is situated in Raufoss Industrial Park, where you find the leading know-how in metallurgy and machining technology in
More informationOperations and Instruction Manual Might Swivel - Part # 310273 Concrete and Steel Anchorage Connector ANSI Z359.1 10,000 lbs / 44kn
Safety.. Operations and Instruction Manual Might Swivel - Part # 310273 Concrete and Steel Anchorage Connector ANSI Z359.1 10,000 lbs / 44kn Description: Technical: Zinc plated forged heat treated steel,
More informationGUY-GRIP Dead-end NOMENCLATURE GENERAL INFORMATION SAFETY CONSIDERATIONS 19-2. (440) 461-5200 inquiries@preformed.com www.preformed.
GUY-GRIP Dead-end NOMENCLATURE Cross-over Marks*: (A) Indicate starting point for application on smaller diameter fittings described on the reverse side of this page. (B) Indicates alternate starting point
More informationUser Guide. Model 380260 Insulation Tester / Megohmmeter
User Guide Model 380260 Insulation Tester / Megohmmeter Introduction Congratulations on your purchase of Extech s Insulation Tester/Megohmmeter. The Model 380260 provides three test ranges plus continuity
More informationCable-Gard Static Discharge Reels
Cable-Gard Static Discharge Reels Applications: Static discharge reels are used for grounding portable machines and equipment in hazardous areas, such as fuel transfer trucks, grain elevators, dockside
More informationUser s Manual. Copyright 2014 Trick Technologies Oy
User s Manual Copyright 2014 Trick Technologies Oy Catchbox Pro Module Catchbox Cover Contents 1 Safety Instructions...4-5 2 Quick Start... 6-15 3 Product Description... 16-18 Overview...16 Compatibility...17
More informationELECTRIC KNIFE SHARPENER
PRODUCT MANUAL- M109 MODEL 401 ELECTRIC KNIFE SHARPENER Please read thoroughly before operation and keep for future reference Model 401 Knife Sharpener Specifications Model No. #401 Power Requirements
More informationCommand devices Pull-wire emergency stop switches One-side operation ZS 71 range 6.1 6.1.1 6.1.1.1. 312 Schmersal -10 0 10 20 30 40 50 60 70 T [] C
.1.1.1 One-side operation ZS 71 range 40 30 ø10 10 53,5(63)* 6 8 18 24 105 33 56 12 22 M20x1,5 52 17,5 42 15 Features To EN 418 / IEC 60947-5-5 Metal enclosure 2 contacts Small body 2 cable entries M20
More informationHYDRAULIC LIFT TABLE CART 2200-LB.
HYDRAULIC LIFT TABLE CART 2200-LB. OWNER S MANUAL WARNING: Read carefully and understand all MACHINE ADJUSTMENT AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other
More informationRATCHET RELEASE SHACKLE
RATCHET RELEASE SHACKLE INNOVATIVE PILING EQUIPMENT HYDRAULIC PILING HAMMERS EURO RATCHET RELEASE SHACKLE FOR STEEL ERECTION OPERATORS INSTRUCTIONS & SPARE PARTS LIST EXCAVATOR MOUNTED VIBRATORS EXCAVATOR
More information12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual
12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual This 30Amp charge controller is designed to protect your 12Volt Lead-acid or Gel-cell battery from being overcharge by solar
More informationCURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X
CURRENT TRANSFORMER MODEL 546 1.10" I.D. PAGE No 1-38 REV 15DEC00 TERMINAL OPTION LEAD WIRE OPTION 1.10 0 1.20 2.55 3.00 3.47 0.18 x 0.31 SLOT ( 2 PLACES) 8-32 BRASS STUD (2 PLACES) UL1015 #16 AWG LEAD
More informationCTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute
CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute Cable Tray Wiring Systems Have Many Cost Advantages Cost is usually a major consideration in the selection of a wiring system.
More information1-800-295-5510 uline.com SPECIFICATIONS
H-1394, H-1395, H-1396 H-1397, H-3859, H-3860 π GRAVITY CONVEYOR 1-800-295-5510 uline.com SPECIFICATIONS Conveyor Bed Width In (mm) 18, 24, 30 (457, 610, 762) Load Capacity Per Linear Foot (305mm) Lbs
More informationGround Resistance Clamp On Tester
USER MANUAL Ground Resistance Clamp On Tester MODEL 382357 Introduction Congratulations on your purchase of Extech s 382357 Ground Resistance Tester. This Clamp on device allows the user to measure ground
More informationIEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO
IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO WHEN YOU HEAR AN ENGINEER SAY A NUMBER OF DIFFERENT APPROACHES ARE BEING IMPLEMENTED
More informationToolLasso System. StepladderAccessories. Load Capacity TL2BC-20 TL2BC-12 TL50 TL5-20 TL5-12
LADDER ACCESSORIES Table of Contents Product Page ToolLasso System 1 JobBucket 2 Pail Shelves and Project Trays 2-3 Stepladder Hanger 3 Extension Ladder Stabilizers 4-5 Ladder Levelers 5-6 Misc. Extension
More informationSeries 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
More informationSERVICE GUIDE For WARN PULLZALL 120v AC &100v AC P/N 685000 & 685001
SERVICE GUIDE For WARN PULLZALL 120v AC &100v AC P/N 685000 & 685001 REPAIR / REPLACEMENT INSTRUCTIONS TROUBLE SHOOTING GUIDE 986765A2.doc Page 1 of 50 WARNING This guide identifies potential hazards and
More informationFIBREGLASS LADDERS THE LADDER WITH THE BLUE TRIM
SUPERLITE STEP-LADDER WITH ALUMINIUM TREADS 1 700 700-06 SOLID TRIANGULAR BOTTOM GUSSET PINCH RESISTANT SPREADER BARS Ref. Bar Code No. of steps Weight 700-06 6005413007015 6 8.3kg 700-08 6005413007022
More information[see Figure 3 below] Ferrite tile walls and ceiling RF Absorber parcel walls and ceiling Removable floor section to make fully anechoic
Test Room ID: R21F Description: SEMI ANECHOIC SHIELDED TEST ENCLOSURE Primary Testing Uses: FCC, CE Mark Dimensions: 9.75m x 6.10m x 5.49m (32ft. x 20ft. x 18ft.) [see Figure 3 below] Construction: Galvanized
More informationPowerLine Magnetic-Laser Pulley Alignment System Instructions
MONARCH INSTRUMENT 15 COLUMBIA DRIVE AMHERST, NEW HAMPSHIRE 03031 PHONE: 603-883-3390 FAX: 603-886-3300 E-mail: sales@monarchinstrument.com Web site: www.monarchinstrument.com PowerLine Magnetic-Laser
More informationIMPORTANT DOCUMENTATION DO NOT DISCARD!
PART NO.: 6441-263C SERIES GRT 3 JAW PARALLEL GRIPPERS INFORMATION SHEET IMPORTANT DOCUMENTATION DO NOT DISCARD! Use this information sheet to assist with gripper installation and setup. File with maintenance
More informationPortable Ladder Safety
Portable Ladder Safety Agenda Importance of Ladder Safety An Approved Ladder Controlling Hazards Inspecting the Ladder Set Up Use Importance of Ladder Safety Any fall can be serious, and a fall from the
More information12-Volt 10-Amp Regulated Power Supply
22-506.fm Page 1 Friday, August 6, 1999 12:55 PM Cat. No. 22-506 OWNER S MANUAL Please read before using this equipment. 12-Volt 10-Amp Regulated Power Supply 22-506.fm Page 2 Friday, August 6, 1999 12:55
More informationTBM5, TBM5-S and TBM5-SV
TBM5, TBM5-S and TBM5-SV Compression Tool Instructions Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Table of Contents 1.0 Operating
More information2016 Spring Fall Protection Construction Products
2016 Spring Fall Protection Construction Products Anchorage 3-Man Swiveling Roof Anchor 2103690 Reusable 3-man swiveling roof anchor for sloped wood structures with fasteners. Concrete D-ring Anchor 2104560
More informationBETA Protecting SITOR Semiconductor Fuses
BETA Protecting SITOR Semiconductor Fuses /2 Product overview /3 /17 SITOR, cylindrical fuse design /22 SILIZED, NEOZED and DIAZED design Siemens ET B1 /2008 Product overview Overview Devices Page Field
More informationFall Protection Guidelines
OCT 2015 1 of 6 Fall Protection Guidelines 1.0 PURPOSE To establish the requirements and procedures to protect employees and other persons conducting work from hazards associated with falling from one
More informationMachine Safety Switch: SI-LM40 Series Limit Switch Style
Machine Switch: SI-LM40 Series Limit Switch Style SI-LM40 Series Limit Switch Style with Flexible In-Line Actuator Positive-opening safety contacts (IEC 60947-5-1) (not dependent upon springs) Standard
More informationConnect. Cable preparation and cutting tools
Connect Cable preparation and cutting tools 390 Our range of cable preparation tools includes hand-operated & ratchet action cable cutting tools, wire preparation & stripping tools and SWA & hydraulic
More informationLOXONE 12 Channel Amplifier
LOXONE 12 Channel Amplifier Item no.: 200110 Thank you for purchasing the Loxone Twelve Channel Amplifier. The versatility of the Amplifier makes it the perfect choice for almost every type of custom multi-room
More informationACTIV-8 PLUS Insulated Conductor Bar
ACTIV-8 PLUS Insulated Conductor Bar A product made in Australia www.conductix.com.au ACTIV-8 PLUS ACTIV-8 is the most widely used and stocked conductor rail in use in Australia. It was designed by Conductix
More informationATL Fuel Level Sender Probes
T E C H N I C A L S P E C I F I C A T I O N The ATL EL-AD-151 (Resistance Output) and EL-AD-152 (Voltage Output) Fuel Level Senders are highly advanced sensors for continuously measuring the contents of
More informationSSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals
SSW-iLM Keypad Note: This product is designed to be installed and serviced by security and lock industry professionals Specifications Case dimensions: 6 1/2 L x 1 3/4 W x 1 1/8 D Electrical: 5-12VDC Only
More informationPowerLine Magnetic-Laser Sheave Alignment System Instructions
PowerLine Magnetic-Laser Sheave Alignment System Instructions The PowerLine Magnetic-Laser Sheave Alignment System laser aligns belts, pulleys, sheaves, sprockets, gear trains, rollers, platforms, conveyors,
More informationSurvival Laser SL-001BB Laser Parts Bundle Assembly & Operation Instructions
Survival Laser SL-001BB Laser Parts Bundle Assembly & Operation Instructions WARNING: READ ALL INSTRUCTIONS AND THE ENCLOSED SAFETY PRECAUTIONS BEFORE ASSEMBLY AND USE Assemble and use these parts ONLY
More informationTransformer Bushings for GIS
Transformer Bushings for GIS Oil to SF6 Connections GARIP RTKG 725-55 kv SQS certified ISO 91 / ISO 141 Bushings RIP - Technology for SF6 / Oil - Bushings In modern metal enclosed switchgear SF6 -gas is
More informationModel WH20 User Guide
Model WH20 User Guide 2005, Shure Incorporated 27G3078 (Rev. 7) Printed in U.S.A. GENERAL The Shure Model WH20 is a rugged, light-weight, dynamic headset microphone that provides high-quality voice pickup.
More informationRIGGING HARDWARE ASME B30.26. Addresses detachable lifting hardware for lifting purposes
RIGGING HARDWARE ASME B30.26 Addresses detachable lifting hardware for lifting purposes Adjustable Hardware (Turnbuckles, Eye nuts, Swivel Hoist Rings and Eyebolts Compression Hardware (Wire Rope Clips
More informationSolar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual
Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual 255379 Rev. D0 1015 Printed in U.S.A. Copyright 2015 Federal Signal Corporation Limited Warranty The Alerting and Notification
More informationTrillium 40 Axis Spring Tensioner Wire Replacement Instructions
Trillium 40 Axis Spring Tensioner Wire Replacement Instructions 1 Overview The objective is to replace the broken axis spring tensioner wire. This requires the following tasks: 1. Remove the seismometer
More informationElkhorn Construction, Inc. Safety Manual Title: Fall Protection Policy Effective Date: 03-01-2000
1. General Requirements (OSHA References: OSHA 29 CFR 1926.503) 1.1 Elkhorn Construction, Inc. employee-owners and subcontractors are required to use fall protection equipment or systems when an assessment
More informationAuto-belay Cable Replacement Process
Auto-belay Cable Replacement Process Version 2.00 WARNING: The air pressure in the auto-belay system is what causes the cable to be retracted when releasing the cable or climbing the wall with the cable
More informationAMPSEAL* Automotive Plug Connector and Header Assembly
AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2
More information