1 ValveMate 7100 Controller Operating Manual IMPORTANT! Save this Sheet. Forward to Maintenance or Tool Crib Supervisors Electronic pdf files of EFD manuals are also available at
2
3 Contents Introduction... 4 EFD Product Safety Statement Preventative Maintenance Specifications Front Panel Buttons/Modes of Operation Indicator Lamps How To Typical Setup Mounting the ValveMate External Power Adapter Back Panel Markings Input/Output Connections I/O Connections Schematics Air Connections Final Setup Checklist Testing the Dispense Valve Troubleshooting Guide Replacement Parts List Warranty... back cover 3
4 Introduction You have selected a reliable, high quality ValveMate dispensing system from Nordson EFD, the world leader in fluid dispensing. The ValveMate dispensing system was designed specifically for industrial dispensing, and will provide you with years of trouble-free, productive service. This manual will help you maximize the usefulness of your ValveMate dispensing system. Please spend a few minutes to become familiar with the controls and features. Follow our recommended testing procedures. Review the helpful information we have included, which is based on more than 30 years of industrial dispensing experience. Most questions you will have are answered in this guide. However, if you need assistance, please do not hesitate to contact Nordson EFD or your authorized Nordson EFD distributor. In Asia, call +86 (21) In Europe, call +44 (0) In the USA, call between 8:30 a.m. and 5:30 p.m. Eastern time. In all other areas, call your authorized Nordson EFD distributor or The EFD Pledge Thank You! You have just purchased the world s finest dispensing equipment. I want you to know that all of us at EFD value your business and will do everything in our power to make you a satisfied customer. If at any time you are not fully satisfied with our equipment or the support provided by your EFD Product Application Specialist, please contact me personally at (US), (outside US), or [email protected] I guarantee that we will resolve any problems to your satisfaction. Thanks again for choosing EFD. Ken Forden Ken Forden, General Manager 4
5 IMPORTANT: The primary control of deposit size is the valve open time. The ValveMate 7100 provides easy access and on the fly adjustment of valve open time. The ValveMate 7100 is an EFD dispense valve controller, incorporating programmable dispense time, digital time readout, keypad programming for easy user interface and input/output communication with host machine PLCs. Other features include: Push-button time setting or one touch time programming. Floating decimal, providing dispense time ranges of.001 to 99.9 seconds. Bright red LED display. Push-button purge feature. Low air-pressure, optional tank low level detection, or other alarm detection devices. End-of-Cycle feedback signal. The ValveMate 7100 has been designed with the machine builder and operator in mind. The objectives are to bring dispensing control close to the point of application, and to provide the features necessary to make setup and operation as easy and precise as possible. The ValveMate is easy to operate. Once you have reviewed the features, you will understand the benefits and the ease of control the ValveMate provides. As with all EFD products, the ValveMate has been produced to exacting specifications and thoroughly tested prior to shipment. To obtain maximum performance from this equipment, please read the instructions carefully. Safety Please read the EFD product safety statement included in the package. Follow all appropriate safety instructions. 5
6 Nordson EFD Product Safety Statement This statement provides personal and equipment safety notices for EFD dispensing systems including benchtop dispensers and ValveMate controllers. WARNING The safety message that follows has a WARNING level hazard. Failure to comply could result in death or serious injury. ELECTRIC SHOCK Risk of electric shock. Disconnect power before removing cover and/or disconnect, lock out, and tag switches before servicing electrical equipment. If you receive even a slight electrical shock, shut down all equipment immediately. Do not restart the equipment until the problem has been identified and corrected. CAUTION The safety messages that follow have CAUTION level hazards. Failure to comply may result in minor or moderate injury. READ MANUAL Read manual for proper use of this equipment. Follow all safety instructions. Task- and equipment-specific warnings, cautions and instructions are included in equipment documentation where appropriate. Make sure these instructions and all other equipment documents are accessible to persons operating or servicing equipment. MAXIMUM AIR PRESSURE Maximum air input pressure 100 psi (6.9 bar). Excessive air input pressure may damage the equipment. BURST PRESSURE Maximum air input pressure 100 psi (6.9 bar). Burst pressure 300 psi (20.7 bar). Excessive air input pressure may damage the equipment. RELEASE PRESSURE Release pressure before opening. Maximum pressure 30 psi (2.0 bar). Release hydraulic and pneumatic pressure before adjusting or serving pressurized systems or components. 6
7 Halogenated Hydrocarbon Solvent Hazards Do not use halogenated hydrocarbon solvents in a pressurized system that contains aluminum components. Under pressure, these solvents can react with aluminum and explode, causing injury, death, or property damage. Halogenated hydrocarbon solvents contain one or more of the following elements. Element Symbol Prefix Fluorine F Fluoro- Chlorine Cl Chloro- Bromine Br Bromo- Iodine I Iodo- Check your material MSDS or contact your material supplier for more information. If you must use halogenated hydrocarbon solvents, contact your EFD representative for compatible EFD components. High Pressure Fluids High pressure fluids, unless they are safety contained, are extremely hazardous. Always release fluid pressure before adjusting or servicing high pressure equipment. A jet of high pressure fluid can cut like a knife and cause serious bodily injury, amputation, or death. Fluids penetrating the skin can also cause toxic poisoning. Warning: Any injury caused by high pressure liquid can be serious. If you are injured or even suspect an injury: Go to an emergency room immediately. Tell the doctor that you suspect an injection injury. Show the doctor this note. Tell the doctor what kind of material you were dispensing. Medical Alert Airless Spray Wounds: Note to Physician Injection in the skin is a serious traumatic injury. It is important to treat the injury surgically as soon as possible. Do not delay treatment to research toxicity. Toxicity is a concern with some exotic coatings injected directly into the bloodstream. Qualified Personnel Equipment owners are responsible for making sure that EFD equipment is installed, operated and serviced by qualified personnel. Qualified personnel are those employees or contractors who are trained to safely perform their assigned tasks. They are familiar with all relevant safety rules and regulations and are physically capable of performing their assigned tasks. Continued on next page 7
8 Intended Use Use of EFD equipment in ways other than those described in the documentation supplied with the equipment may result in injury to persons or damage to property. Some examples of unintended use of equipment include: using incompatible materials making unauthorized modifications removing or bypassing safety guards or interlocks using incompatible or damaged parts using unapproved auxiliary equipment operating equipment in excess of maximum ratings operating equipment in an explosive atmosphere Regulations and Approvals Make sure all equipment is rated and approved for the environment in which it is used. Any approvals obtained for EFD equipment will be voided if instructions for installation, operation and service are not followed. Personal Safety To prevent injury, follow these instructions: Do not operate or service equipment unless you are qualified. Do not operate equipment unless safety guards, doors or covers are intact and automatic interlocks are operating properly. Do not bypass or disarm any safety devices. Keep clear of moving equipment. Before adjusting or servicing moving equipment, shut off the power supply and wait until the equipment comes to a complete stop. Lock out power and secure the equipment to prevent unexpected movement. Make sure spray areas and other work areas are adequately ventilated. Know where emergency stop buttons, shutoff valves and fire extinguishers are located. When using a syringe barrel, always keep the dispensing end of the tip pointing towards the work and away from the body or face. Store syringe barrel with tip pointing down when not in use. Obtain and read Material Safety Data Sheets (MSDS) for all materials used. Follow the manufacturer s instructions for safe handling and use of materials, and use recommended personal protection devices. To prevent injury, be aware of less-obvious dangers in the workplace that often cannot be completely eliminated, such as hot surfaces, sharp edges, energized electrical circuits and moving parts that cannot be enclosed or otherwise guarded for practical reasons. 8
9 Fire Safety To avoid a fire or explosion, follow these instructions: Shut down all equipment immediately if you notice static sparking or arcing. Do not restart the equipment until the cause has been identified and corrected. Do not smoke, weld, grind or use open flames where flammable materials are being used or stored. Do not heat materials to temperatures above those recommended by the manufacturer. Make sure heat monitoring and limiting devices are working properly. Provide adequate ventilation to prevent dangerous concentrations of volatile particles or vapors. Refer to local codes or your material MSDS for guidance. Do not disconnect live electrical circuits when working with flammable materials. Shut off power at a disconnect switch first to prevent sparking. Know where emergency stop buttons, shutoff valves and fire extinguishers are located. Action in the Event of a Malfunction If a system or any equipment in a system malfunctions, shut off the system immediately and perform the following steps. Disconnect and lock out system electrical power. If using, close hydraulic and pneumatic shutoff valves and relieve pressures. Identify the reason for the malfunction and correct it before restarting the system. For air-powered dispensers, remove syringe barrel from adapter assembly. For the electromechanical dispensers, slowly unscrew the barrel retainer and remove barrel from actuator. Disposal Dispose of equipment and materials used in operation and servicing according to local codes. 9
10 Preventative Maintenance As part of maintaining continuous trouble-free use of this product, EFD recommends a few very simple preventative maintenance checks. 1. Periodically inspect tube to fitting connections for proper fit. Secure as necessary. 2. Check tubing for cracks and contamination. Replace tubing as necessary. 3. Check all wiring connections for looseness. Tighten as necessary. 4. Clean: If front panel requires cleaning, use a clean, soft damp rag with a mild detergent cleaner. DO NOT USE strong solvents (acetone, MEK, etc.) as they will damage the front panel material. 5. Maintain: Only use clean dry air to unit. Equipment does not require any other regular maintenance. 6. Test: Verify operation of features and performance of equipment using the appropriate sections of this users guide. A faulty or defective unit should be returned to EFD or representative for refurbishment. 7. Use only replacement parts that are designed for use with original equipment. Contact your EFD representative for information and advice. RoHS 标 准 相 关 声 明 (China RoHS Hazardous Material Declaration) 产 品 名 称 Part Name 有 害 物 质 及 元 素 Toxic or Hazardous Substances and Elements 铅 汞 镉 六 价 铬 多 溴 联 苯 多 溴 联 苯 醚 Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated Chromium Biphenyls Diphenyl Ethers (Pb) (Hg) (Cd) (Cr6) (PBB) (PBDE) 外 部 接 口 External Electrical X O O O O O Connectors O: 表 示 该 产 品 所 含 有 的 危 险 成 分 或 有 害 物 质 含 量 依 照 EIP-A, EIP-B, EIP-C 的 标 准 低 于 SJ/T 限 定 要 求 Indicates that this toxic or hazardous substance contained in all the homogeneous materials for this part, according to EIP-A, EIP-B, EIP-C is below the limit requirement in SJ/T X: 表 示 该 产 品 所 含 有 的 危 险 成 分 或 有 害 物 质 含 量 依 照 EIP-A, EIP-B, EIP-C 的 标 准 高 于 SJ/T 限 定 要 求. Indicates that this toxic or hazardous substance contained in all the homogeneous materials for this part, according to EIP-A, EIP-B, EIP-C is above the limit requirement in SJ/T
11 Specifications Note: Specifications and technical details are subject to engineering changes without prior notification. Cabinet Size: 14.0 cm x 14.2 cm x 6.8 cm (5.5 W x 5.6 D x 2.7 H) Weight: 1.18 kg (2lbs 9oz) Electrical Power Input: 24VDC (+/- 5%), 0.63A maximum Electrical Input Connector: Switchcraft L722RA or equivalent, locking type External Power Adapter: VAC (+/-10%),~ 50/60 Hz input, 24VDC (+/- 5%), 0.63 A output, Switchcraft S761K locking DC plug or equivalent, wall mount, changeable AC plugs. Feedback Circuits: EOC Out & Alarm Out: Electronic switch, 24VDC, 100mA maximum. Initiate Circuits: 5-24 INIT: 5-24VDC initiate signal. CC INIT & Foot Switch: Dry contact initiate circuits, 19mA, closure current. INIT signal duration: No less than sec. momentary or maintained for steady. Cycle Rate: Exceeds 600 per minute Time Range: Programmable to 99.9 seconds Ambient operating conditions: Temperature: 5 C to 45 C (41 F to 113 F) Humidity: 85% RH at 30 C, 40% at 45 C non-condensing Height above sea level: 2000 meters max (6,562 feet) This equipment is for indoor use only. Product Classification: Installation Category II Pollution Degree 2 Meets or exceeds CE and CSA requirements 11
12 Front Panel Buttons/Modes of Operation POWER Press Power button to turn power ON or OFF. Note: ValveMate 7100 will always power up into RUN mode. RUN SETUP Enables external initiate inputs. The cycle button is disabled. Setup, testing and modification of dispense time. STEADY Timer override. Press UP/DOWN to toggle between TIME and STEADY operation. TEACH PURGE For easy setting and teaching of time mode in filling or other longer cycle applications. Enables purging of dispense valve. CYCLE Pressing the button will provide different results according to the selected MODE. TIME SET Pressing the buttons will decrement or increment valve on-time. In SETUP or TEACH mode, pressing both buttons simultaneously will zero out the time. The up and down time adjustment buttons are available in SETUP, TEACH and RUN modes. ALARMS 1. Low Air Pressure Alarm: Assures sufficient pressure is present for valve operation. Can be disabled. 2. CC INIT (Contact Closure Initiate): Optional usage of the CC INIT for external alarm applications. Examples of uses: low tank level switch, operator safety interlock, etc. Alarm conditions are assessed, (air pressure less than 60 psi and CC INIT open) just prior to the start of a dispense operation. MODE Press the MODE button to cycle through SETUP modes. EXTENDED USER SETUP FUNCTIONS Low Air Pressure Alarm: ON / OFF Pressure Units: Psi / Bar CC INIT : Enable for Alarm IN 12
13 Indicator Lamps The indicator lamp at the upper left corner above LED display will illuminate whenever the dispense valve is actuated. The center front panel has five indicator lamps used to indicate the operation mode RUN MODE SETUP STEADY TEACH PURGE CYCLE 13
14 How to make On-the-Fly (OTF) time adjustments in RUN mode: Step 1 Press CYCLE button to enable OTF, display will blink. Step 2 Press or buttons to adjust valve on time. Step 3 Press CYCLE button to disable OTF, display no longer blinks. How to set controller to STEADY mode: Step 1 Press MODE button and scroll to STEADY. Step 2 Press or to toggle between TIME and STEADY operation. Step 3 When appears on LED display, press mode button to return to RUN. How to use the TEACH mode: Step 1 Press MODE button and scroll to TEACH. Step 2 Press and hold CYCLE button or depress the foot pedal in the TEACH mode. LED display will begin flashing before TEACH function begins. Step 3 Add incremental time by continued press and hold of CYCLE button or depress and hold the foot pedal. Step 4 To fine tune programmed pulse time, press or to decrease/increase time. Step 5 Press both to.000 out time to and restart the TEACH process. How to use PURGE mode: Step 1 Press MODE button and scroll to PURGE. Step 2 Press CYCLE button or depress foot pedal to purge dispense valve. 14
15 How to enable/disable low air pressure alarm: Step 1 Press MODE button and scroll to STEADY. Step 2: Press and hold until Aon or Aof is visible. Step 3 Press or button to toggle between Alarm On or Alarm OFF. Step 4 Press MODE button to exit. How to select PSI or BAR pressure readout: Step 1 Press MODE button and scroll to STEADY. Step 2: Press and hold until Aon or Aof is visible. Step 3 Press button one time. Step 4 Press or button to toggle between for BAR, and for Psi. Psi Format: 0. to 101. BAR Format: 0.0 to 7.0 Step 5 Press MODE button to exit. How to enable/disable CC INIT I/O as an external alarm input: Step 1 Press MODE button and scroll to STEADY. Step 2: Press and hold until Aon or Aof is visible. Step 3: Press two times. Step 4: Press or button to toggle between CCI or ALI CC INIT function is: CCI: Contact Closure initiate input ALI: External alarm input Step 5 Press MODE button to exit. 15
16 Typical Setup Five micron filter regulator To exhaust To pressurize Flexible air line Plant air 70 psi (4.8 bar) White quick-connect Shut-off valve Black quick-connect Air tee Fluid feed hose Pressure relief valve Constant air NOTE: Use only oil-free, clean, dry filtered air Actuating air EFD dispense valve Pressurized reservoir with air regulator EFD Model 615 ValveMate 7100 Controller Caution: Always depressurize the reservoir before opening. To do this, slide the shutoff valve on the air line away from the reservoir. If using an EFD tank, open the pressure relief valve as well. Before opening the reservoir, check the pressure gauge to verify that pressure is zero (0). On all EFD cartridge reservoirs, the unique threaded design provides fail-safe air pressure release during cap removal. 16
17 Mounting the ValveMate 7100 Mounting The ValveMate 7100 can be mounted either over or under a surface using screws to secure bracket. Use the universal mounting bracket (included) to mount the controller either over or under the cabinet. The bracket allows the controller to pivot 30º from a horizontal position. When mounted under a workbench, secure with screws or nuts and bolts to support 14lbs. Optional Panel Mount Kit For panel mounting, an optional panel mount bracket kit is available. (Order part # ) 4X 13/64" 5.16mm 5.313in 13.49cm 4X R.156in 0.40cm 2.710in 6.88cm 1.000in 2.54cm Panel Cutout Dimensions 2.398in 6.09cm.881in 2.24cm 5.625in 14.29cm 6.451in 16.39cm 17
18 External Power Adapter A universal 24VDC remote power supply with a locking ring DC connector is included with each ValveMate Select a convenient location and connect to appropriate input voltage. Back Panel Markings Maximum Air Pressure Caution Caution symbol informing that the maximum air input pressure is 100 psi (6.9 bar). Excessive air input pressure may damage the equipment. 2 Foot Pedal / Finger Switch Connector Switch symbol identifies the connector for a momentary contact closure switch for dispense initiates. An optional foot pedal, part # may be ordered. Power Input Current Input current symbol specifying that DC current is utilized on the power supply connector. The current is derived from an external 24 VDC source. Chassis Connection This symbol identifies the chassis connection terminal. Used for grounding the chassis to shunt leakage current and/or enhance system ESD protection. 18
19 Input/Output Connections The 10 pin terminal strip includes a 5-24VDC and contact closure CC initiate inputs. Outputs include an Alarm Out, End of Cycle (EOC) and a 24VDC courtesy power INIT: Dispense initiate input activated with a 5-24VDC input voltage. EOC OUT: End-of-cycle feedback ALARM OUT: Circuit that closes when an alarm condition is present. CC INIT: Dispense initiate input activated with a contact closure switch. 24VDC OUT: Courtesy output 24VDC, 200mA. Note: ALARM OUT and EOC (End-of-cycle) only function in RUN mode. 19
20 Initiate Connections The 7100 can be initiated by three inputs: INIT: Application of 5-24 VDC to the 5-24 INIT terminals, pins CC INIT: Application of mechanical contacts on CC INIT terminals, pins Foot Pedal: Use of Optional EFD foot pedal (part number ) plugged into foot pedal receptacle. A connection schematic is detailed on page 21. Alarm OUT Connection The ValveMate 7100 features an alarm output circuit. The Alarm OUT circuit closes when an alarm condition is present.the Alarm OUT circuit is a normally open electronic switch that can switch an external 5-24 VDC circuit to an external signaling device or PLC input. Maximum load is 100mA, 5-24 VDC. Alarm IN Connection The ValveMate 7100 offers an alternate use of the CC INIT initiate input for an external alarm signal. Refer to the How to instructions on page 15 to enable. When enabled as an alarm input the CC INIT on pins 7 and 8 is connected to a normally closed switch such as a low level reservoir float switch. Pins 7 and 8 must be closed to initiate a dispense valve cycle. End-of-Cycle Connection (EOC) The ValveMate 7100 features an End-of-Cycle (EOC) circuit to acknowledge an active dispense valve initiate. The EOC circuit is a normally closed electronic switch that can switch an external 5-24 VDC circuit to an external signaling device or PLC input. Maximum load is 100mA, 5-24 VDC. End of Cycle (EOC) signaling only functions when the ValveMate 7100 is in the RUN mode. The End-of-Cycle (EOC) is normally closed in RUN mode while dispense cycle is inactive. The EOC switch opens when the dispense cycle is initiated and closes when the dispense cycle is completed. 24 VDC Output Courtesy 24 volt DC 200mA can be used to provide power to EOC and Alarm out circuits for signalling purposes. Also, can be used as a power source for an indicator device or initiate signal through a contact closure switch to the 5-24 INIT circuit. 20
21 I/O Connection Schematics + + INPUTS POWER IN 24 VDC 0.63 A MAX. VOLTAGE INITIATE 5-24 VDC 3 ma AT 5VDC 19 ma AT 24 VDC CC INIT NO SWITCH 19 ma MAX. or ALARM IN NC SWITCH 19 ma MAX. OUTPUTS + + SWITCH CLOSURES 24 VDC MAX. 100 ma MAX. + - COURTESY SUPPLY 24 VDC 200 ma MAX. I/O External Wiring Diagram +24Vdc COM K 1.2K K 100mA 100mA 200mA EOC ALARM + CC VDC - INIT OUT OUT INIT OUT I/O Electrical Schematic 21
22 Air Connections Installing the Dispense Valves All EFD valves are supplied with an installation manual. The manual will explain the operation of the valve and also how to set up the valve with the fluid reservoir. Connect the valve actuating air hose to the AIR OUTPUT 1 at the back of the ValveMate 7100 controller. Air Input Connection 2 1 Connect the ValveMate 7100 to plant air by first installing the EFD five-micron filter regulator (# ) included to your air supply. Install the air tee with push-in fitting (# ) in the output of the filter regulator. (Included with EFD tank/ cartridge reservoirs) 3 meters (9 ft) of 6 mm OD air line is supplied. Using the 6mm push-in fitting supplied, connect one end to the # air tee. Connect the other end of the air line by pushing it firmly into the AIR INPUT connector on the ValveMate 7100 until it bottoms out. Be sure that the line is inserted all the way into the fitting. Set the pressure at the # filter regulator to 70 psi (4.8 bar). The quick-connect on the air tee is used to provide air pressure to the air pressure regulator on EFD fluid reservoirs. This connection will be made at a later step in the setup. IMPORTANT Air output push-in fitting has an internal safety stop valve. Make certain valve air hose is fully inserted into fitting to allow proper air flow. 22
23 Final Setup Checklist 1. Air pressure to ValveMate 7100 is set to 70 psi (4.9 bar). 2. Initiate connection and I/O are wired correctly. 3. Valve and fluid reservoir are properly connected. 4. Valve is set up and dispensing tip installed in accordance with the dispense valve installation guide. 5. Turn power on. Confirm indicator lamps and LED display is lit
24 Testing the Dispense Valve 1. Set tank pressure. For low viscosity, low pressures and high viscosity, higher pressure. 2. Using the Mode button on the ValveMate controller, place the controller in the PURGE mode. 3. Place a container under the valve and press the CYCLE button to open the valve and flow material until all air is purged from the system. Adjust the tank pressure, or valve stroke knob to set a flow rate that is not too low or too high. A high flow rate will make setting up a small dot difficult or could cause splashing. 4. Using the Mode button again, place the controller in the Setup mode. Using the up/ down buttons below the LED, set a dispense time of.050 seconds. 5. Press the CYCLE button to initiate a dispense cycle. Increase or decrease the time or tank pressure to arrive at the desired deposit size. The primary control of deposit size is the valve open time. 6. The system is now ready to be initiated by the machine controls when the machine is started. ValveMate 7100 must be in RUN mode. 24
25
26 Troubleshooting Guide Trouble LED toggles between Air and pressure value and will not accept initiate signal. Possible cause and correction Air pressure to the ValveMate 7100 has dropped below 60 psi. Raise the input pressure to 70 psi (4.8 bar). Press MODE button to reset. If problem persists, make sure devices such as air cylinders are not causing a pressure drop in the ValveMate 7100 input air line. Unit is not responding to the initiate signal. Check to make sure the unit is not in a mode other than RUN. Response delay in pneumatic circuit does not allow the valve to open when time is set at or below seconds. Increase time. The signal must break cleanly before the next signal is initiated. Timer is inoperative. LED is blinking Check to make sure the unit is not in the steady mode. External alarm is enabled and circuit is open. Check cause for fault or disable. See page 15: How to enable/disable CC INIT as an external input. If trouble cannot be corrected, or if you need further assistance, please call us. USA UK Asia +86 (21)
27 Replacement Parts List Valvemate KIT FITTING-4MM BULKHEAD KIT POWER SUPPLY DC EXTERNAL 7100 / 7140 Not shown KIT VALVE SOLENOID 24VDC 1.8W WITH CONN KIT CONN TERMBLOK PLUS IO 10POS 5.08MM KIT BRACKET PIVOT, 7100 Not shown KIT M4X20MM THUMB SCREW ASSEMBLY KIT DC CABLE ASSEMBLY-2M-LOCKING CONN Not shown KIT PANEL MOUNT 7100/7140 Not shown
28 NORDSON EFD ONE YEAR LIMITED WARRANTY All components of the Nordson EFD ValveMate 7100 are warranted for one year from date of purchase to be free from defects in material and workmanship (but not against damage caused by misuse, abrasion, corrosion, negligence, accident, faulty installation or by dispensing material incompatible with equipment) when the equipment is installed and operated in accordance with factory recommendations and instructions. Nordson EFD will repair or replace free of charge any part of the equipment thus found to be defective, on authorized return of the part prepaid to our factory during the warranty period. In no event shall any liability or obligation of Nordson EFD arising from this warranty exceed the purchase price of the equipment. This warranty is valid only when oil-free, clean, dry, filtered air is used. Nordson EFD makes no warranty of merchantability or fitness for a particular purpose. In no event shall Nordson EFD be liable for incidental or consequential damages. For Nordson EFD LLC sales and service in over 30 countries, contact Nordson EFD or go to www. nordsonefd.com East Providence, RI USA USA & Canada: ; [email protected] Dunstable, Bedfordshire, UK ; +44 (0) Ireland [email protected] Nordson India Private Limited [email protected] China: +86 (21) [email protected] Singapore: [email protected] The Wave Design is a trademark of Nordson Corporation Nordson Corporation 7100-MAN-EN v This equipment is regulated by the European Union under WEEE Directive (2002/96/EC). See for information about how to properly dispose of this equipment.
Leak Detection System
Instructions - Parts List Leak Detection System 311200A For detecting leaks in your diaphragm pump system. Not for use in explosive atmospheres. Part No. 234576 120 psi (0.8 MPa, 8 bar) Maximum Air Input
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
Installation Instructions for Alarm Module Kit A043F059
Instruction Sheet 07-2013 Installation Instructions for Alarm Module Kit A043F059 1 Introduction The information contained within is based on information available at the time of going to print. In line
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE Cable Processor Module overview WARNING! When tipping the Cable Processor Module back, (after removing the toggle arm pin), use extreme caution not to drop
Manual for Fire Suppression & Methane Detection System
Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327
PICO Toµch Controller
PICO Toµch Controller Operating Manual Electronic pdf files of Nordson EFD manuals are also available at www.nordsonefd.com You have selected a reliable, high-quality dispensing system from Nordson EFD,
Dehumidifier Users manual. For Models: DH45S DH65S
Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but
INSTALLER S & OWNER S MANUAL
INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000 DEH 3000 Part No. 4028539 Dehumidifier & Ventilation System Controller P.O. Box 8680 Madison, WI 53708 TOLL-FREE
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
Remote Alarm Monitoring System
Remote Alarm Monitoring System Operation and Service Manual Model RA1 RA4 A A Version HELMER SCIENTIFIC 14400 Bergen Boulevard Noblesville, IN 46060 USA PH +1.317.773.9073 FAX +1.317.773.9082 USA and Canada
ATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
240-3118 AIR CUT OFF KIT INSTALLATION INSTRUCTIONS
OPERATION MANUAL GLOBAL ELECTRONIC MIX SOLUTIONS PLURAL COMPONT MIXING SYSTEM 240-3118 AIR CUT OFF KIT INSTALLATION INSTRUCTIONS 77-3087-R1.0 (8/2015) 1 / 5 In this part sheet, the words WARNING, CAUTION
PRO Series and EV Series Automated Dispensing Systems
PRO Series and EV Series Automated Dispensing Systems Operating Manual Electronic pdf files of Nordson EFD manuals are also available at www.nordsonefd.com You have selected a reliable, high-quality dispensing
Water Leak Detection System
Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:[email protected] 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright
MIC-WKT and MIC-WKT-IR
MIC-WKT and MIC-WKT-IR Installation Manual Bosch Security Systems EN Installation and Operation Manual MIC-WKTI and MIC-WKT-IR Installation Manual EN 2 MIC-WKT and MIC-WKT-IR Washer Pump Drive Card Kits
OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE
OASIS-PLUS 120V INFORMATION & OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE 56041852 WARNING:
Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
DIAMOND Retractable Rodding Robot Model SPRAYROD-R
2004-12-21 2 1 (23) DIAMOND Retractable Rodding Robot Model SPRAYROD-R 2004-12-21 2 2 (23) Table of contents 1 TECHNICAL DESCRIPTION...4 1.1 MAIN DETAILS...5 1.2 COMPONENTS DESCRIPTION...5 1.2.1 Pneumatic
TIG INVERTER INSTRUCTION MANUAL
TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4
Model 1756 Test Lead Kit
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 1756 Test Lead Kit Gerneral Purpose Test Lead Information Description These test leads allow you
INSTRUCTION MANUAL MODEL PCD-88
INSTRUCTION MANUAL MODEL PCD-88 CLOSED CAPTION DECODER LINK ELECTRONICS, INC. 2137 Rust Avenue Cape Girardeau, Missouri 63703 Phone: 573-334-4433 Fax: 573-334-9255 e-mail: sales @ linkelectronics.com website:
IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White
IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting
RGC-IR Remote Gas Calibrator for IR400
Remote Gas Calibrator for IR400 The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by
VOYAGER 570G. 744A Sprayer Control
VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER
How To Size A Stenner Pump
Metering Pumps Manufactured Since 1957 PCM Series Pump Control Module INSTALLATION AND MAINTENANCE MANUAL Table of Contents WarrantyandServicePolicy...3 Safety Information...............................................
The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.
i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive
MODEL G300 BRAKE BLEEDER
MODEL G300 BRAKE BLEEDER Installation, Operation & Repair Parts Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV060616 P/N: 81-0035G 1 THIS PAGE INTENTIONALLY
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075
Part No. 89047 Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075 Cincinnati, OH 45241-4807 USA ELECTRIC FRYER SAFETY PRECAUTIONS Installation
Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.
Name of Equipment Silver King Model SKMCD1P/C1 This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Manufactured exclusively for McDonald s By Silver King Refrigeration,
GENANO 4500 MEDICAL AIR PURIFICATION DEVICE
GENANO AIR PURIFICATION TECHNOLOGY GENANO 4500 MEDICAL AIR PURIFICATION DEVICE OPERATING INSTRUCTION 1 GENANO LTD Kimmeltie 3 FI- 02110 Espoo, Finland Tel + 358 9 7743 870 Fax + 358 9 7533 130 www.genano.fi
Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
USER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018
USER S MANUAL MaxPower 400-600 UPS Uninterruptible Power System 28-2MAXPO0018 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models MaxPower 400 and
Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual
Master Time Clock MTC-200 MTC-400 MTC-600 Users Manual Toll Free (888)713-0373 Phone (972)987-4408 FAX (877)720-9291 www.midwest-time.com [email protected] TABLE OF CONTENTS TOPIC PAGE GENERAL DESCRIPTION
Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1
REMOTE METER TM Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1 1098 Washington Crossing Road Washington Crossing, PA 18977 USA www.morningstarcorp.com
User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.
User s Guide Oreck Air Purifier with HEPA Filtration Important! Read this manual carefully, and keep for future reference. Enjoy Congratulations on your purchase of the Oreck Air Purifier with HEPA Filtration.
Geocontrol PRO INSTALLATION AND OPERATION MANUAL. Rev. 1 03/18/04 Part # 11150263
Geocontrol PRO INSTALLATION AND OPERATION MANUAL Rev. 1 03/18/04 Part # 11150263 TABLE OF CONTENTS Chapter 1: System Description... p. 05 Function and Theory...p. 05 Chapter 2: System Installation... p.
USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat
Builder MODEL 1010 Series Non-Programmable Single Stage Heat/Cool Thermostat USER MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage
DC400 Dispensing Cutoff System
DC400 Dispensing Cutoff System DC404 and DC406 Installation Instructions Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838 6433 www.franklinfueling.com
TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation
GTRDD SERIES HEATLESS DRYER INSTALLATION, OPERATION & MAINTENANCE MANUAL TABLE OF CONTENTS SECTION 1 General Information: Pg 2 Description of Operation SECTION 2 Safety Instructions: Pg 3 Installation
Electric Panel Pump Control System. Operation, Maintenance and Installation Manual
Manual No. 5EP-OM1-1 Electric Panel Pump Control System Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION... 2 SEQUENCE
Hydraulic control unit series 0086-372-01
Technical Product Information No. 1290 EN Hydraulic control unit series 0086-372-01 Contents Page About this Technical Product Information (TPI) 2 The ORTLINGHAUS numbering system 2 About the product 3
TMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
ReadyNet Easy Jack 2 Voice/Data and Data Only Owner s Manual PX-211d and PX-211v
ReadyNet Easy Jack 2 Voice/Data and Data Only Owner s Manual PX-211d and PX-211v Phonex Broadband Corporation dba ReadyNet 6952 High Tech Drive Midvale, Utah 84047 801.566.0100 Phone 801.566.0880 Fax www.readynetsolutions.com
English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...
2 Contents Components Attachments Guidance Installation Operation Maintenance Service Technical Troubleshooting Symbols used to mark instructions...3 Included Attachments...4 Congratulations...5 Getting
600-GD & 600-GDL 600 SERIES GAS DETECTOR
600-GD & 600-GDL 600 SERIES GAS DETECTOR INSTALLATION AND OPERATING INSTRUCTIONS This page has been deliberately left blank. Page 1 Table of Contents 1 WARRANTY...3 2 IMPORTANT...3 3 CAUTIONS WHEN USING
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
55-Gallon Dispenser Package
INSTRUCTIONS-PARTS LIST Husky 515 55-Gallon ispenser Package 08666 Rev. C INSTRUCTIONS This manual contains important warnings and information. REA AN KEEP FOR REFERENCE. 100 psi (6.9 bar) Maximum Air
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall
16/32 Channel 1U Rack Mount CCTV Power Supply
16/32 Channel 1U Rack Mount CCTV Power Supply Manual PH-A3224-GUQ Shown 16-Channel 32-Channel PTC PH-A1612-PUQ PH-A3224-PUQ Glass Fuse PH-A1612-GUQ PH-A3224-GUQ Industrial design 12 Amp 3 Amps per channel
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE
DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000
Sip/Puff Switch User Guide
Sip/Puff Switch User Guide www.orin.com Table of Contents Table of Contents... 2 Legal Notices... 3 Declaration of Conformity with European Directives... 3 Application Disclaimer... 4 Introduction... 5
MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS with the 263/742 Logix Control Valve June 2010 Table of Contents Page No.
How To Use A Cdm250 Digital Multimeter
User Manual CDM250 Digital Multimeter 070-6736-03 Copyright Tektronix, Inc. 1987. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this
12 Volt 30 Amp Digital Solar Charge Controller
12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
Benchtop Computer Monitor Generator
Model: 1280B Benchtop Computer Monitor Generator USER MANUAL Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be observed during all phases of
Nexus FS Point of Use Installation Guide
Nexus FS Point of Use Installation Guide Nexus FS POU Install Guide:12152011:rev-12152011 Technical Specifications Dimensions: Height: 43.5 Width: 11.65 Depth: 15 Weight: 34.39 LBS Electrical Specs: Voltage:
User s Manual AURORA 1.2K/2.2K
User s Manual AURORA 1.2K/2.2K Uninterruptible Power System Safety CAUTION This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
Instructions & Safety Information Models A220-20D and A220-20L Version 2
Quick 220 Voltage Converting Power Supply Instructions & Safety Information Models A220-20D and A220-20L Version 2 Quick 220 Systems LLC PO Box 47489 Phoenix, Arizona 85068-7489 800-347-0394 602-938-6057
Extrusion Flo-Valve INSTRUCTIONS-PARTS LIST. 3000 psi (210 bar) Maximum Working Pressure. Model 204 355, Series K. Rev.
INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 306 586 Rev. D Supercedes B Extrusion Flo-Valve Model 204 355, Series K 3000 psi
Wine Cooler with Thermo-Electric Cooling & Heating Technology
Wine Cooler with Thermo-Electric Cooling & Heating Technology Model number: WC-0888H (8-bottles capacity) Instruction Manual Please read carefully and follow all safety rules and operating instructions.
Mobile Data Power Model: MDP-25
Mobile Data Power Model: MDP-25 Topic Section Features... 2 Operational Features Summary... 2 Back-up Battery Power Internal Charger Voltage Spike Protection RF Noise Filtering Warning of Imminent Loss
3M Wrist Strap and Footwear Tester 740. User s Guide
3M Wrist Strap and Footwear Tester 740 User s Guide Table of Contents Section Page Safety Information...3 1.0 General...4 2.0 Description...4 3.0 Operation...5 4.0 Wall Mounting...5 5.0 Wrist Strap Test...6
BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.
BC-5000 BATTERY CAPACITY TESTER OPERATIONS MANUAL COFKO LLC. COPYRIGHT 2010 1 UNPACKING As you unpack your new BC-5000 battery capacity tester, inspect the tester for signs of shipping damage. If shipping
EPM3. Phase Sequence and Motor Rotation Tester. Users Manual
EPM3 Phase Sequence and Motor Rotation Tester Users Manual 1 L1 L2 L3 2 3 A B C CAT 600V 3-PHASE TESTER 5 TEST M1 M2 BATT M3 EPM3 MOTOR ROTATION TESTER EPM3 MOTOR ROTATION DETERMINED WHILE FACING MOTOR
Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC
Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC BAYweb Remote Model BW-BCU5 Owner's Manual Copyright 2009-2010 Bay Controls, LLC Part Number: BW-BCU5DOC Revision: 0.2 April 18, 2010 BAYweb is a
INSTALLATION INSTRUCTIONS BOOST CONTROLLER. Pro Control Input (Optional) Tach. Signal. Speed. Gray. Signal. Green Blue. Orange.
2650-1706-00 INSTALLATION INSTRUCTIONS BOOST CONTROLLER WARNING! The installation of the Auto Meter Boost Controller is recommended only for experienced technicians. This product may damage your engine
HPU14M-DS 2013 Daniels Manufacturing Corp., All Rights Reserved Page 1 of 17 REV. C 7/2013
The DMC HPU14M is a robust, 110V electrically powered hydraulic pump, designed to provide a hydraulic system pressure of 10,000psi. This pump can be used with compatible heads and hoses, designed for a
ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
TS93 EMR T/PT/TDE. Surface applied door closer
TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
GeniSys 12V. Model 7556. Description / Applications. Advanced 12 Vdc Burner Control
PARTS & ACCESSORIES GeniSys 12V Model 7556 Advanced 12 Vdc Burner Control Description / Applications The Beckett GeniSys TM 12V Advanced Burner Control is a 12 Vdc primary safety control for oil burners
User Manual. Humidity-Temperature Chart Recorder. Model RH520
User Manual Humidity-Temperature Chart Recorder Model RH520 Introduction Congratulations on your purchase of the Extech RH520 Temperature + Humidity Chart Recorder. The RH520 measures and displays Temperature,
INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
Your safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...
Model 800 Residential Steam Humidifier Owner s Manual. Includes Safety & Operating Instructions and Warranty Information
Steam Humidifier Model 800 Residential Steam Humidifier Owner s Manual Includes Safety & Operating Instructions and Warranty Information READ AND SAVE THESE INSTRUCTIONS TABLE OF CONTENTS Safety Cautions...
BW-500 BED WEIGHER USER MANUAL
BW-500 BED WEIGHER USER MANUAL 0 1 TABLE OF CONTENTS SPECIFICATION... 3 Equipment... 4 INSTALLING WEIGH BEAM... 5 PREPARATION FOR MEASUREMENT... 6 DP3800 Indicator... 8 POWER SUPPLY... 8 PANEL... 9 KEY
How To Use A Power Supply Unit (Upu)
BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK
FIREPLACE HEATER FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK If you have any questions about the operation of your fireplace heater, please contact Crane Customer Care. Toll Free: 888-599-0992
Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping
Instruction Sheet 102-140 Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping Plant I.D. 001-1024 EFFECTIVE: November
USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions
USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE AeroVironment EV Solutions 2013 AeroVironment, Inc. All rights reserved. AeroVironment, EV Solutions, and the AeroVironment logo are trademarks
Model UT713 OPERATING MANUAL
Model UT713 OPERATING MANUAL TABLE OF CONTENTS TITLE PAGE Introduction Unpacking Inspection Safety Information Turning the Calibrator On Simulating a Thermocouple Measuring a Thermocouple Simulating TC
http://www.coastalamusements.com
Nexus is a Registered Trademark of Coastal Amusements. OWNERS MANUAL 1935 Swarthmore Avenue, Lakewood, NJ 08701 (732)-905-6662 FAX (732)-905-6815 http://www.coastalamusements.com GAME DESCRIPTION Nexus
Infrarot-Bewegungsmelder IP44
Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
ACCUMULATOR INSTALLATION
7001-7 ACCUMULATOR INSTALLATION BRAKE ACCUMULATORS I 308L93 Rae 7-59710 Issued 6-93 Printed in U.S.A 7001-8 Removal ACCUMULATOR VALVE 1. Park the machine on a level surface and lower the. loader bucket
LDG DTS-4/4R Desktop Coaxial Switch / Remote