Selection guide for energy saving products. Energy Saving

Size: px
Start display at page:

Download "Selection guide for energy saving products. Energy Saving"

Transcription

1 Selection guide for energy saving products Energy Saving

2 SMC Energy Saving Gain competitive advantage discover some simple and effective ways to ensure operational savings and improve productivity We are all being urged to save energy. Headlines remind us almost daily of the need to reduce our carbon footprint and adopt a greener lifestyle. It s an important issue and one we ignore at our peril. Growing customer expectations and increasing legislation also mean that businesses can no longer afford to ignore green issues. By adopting an energy saving strategy as a part of your business efficiency programme, not only will you save money but you ll help make a sustainable lifestyle for future generations. Cooling Tower Compressor room Tank Compressor Filter Dryer Flow Switch How can your business benefit by saving energy? Higher global energy prices are hitting everyone, and governments, responsible businesses and consumers are all looking at ways to save money, reduce energy consumption and at the same time help the environment. Whatever business you're in, you have the potential to save energy and money just by making your business more energy efficient. For example, did you know that the average business wastes around 0% of the energy it uses! As world leaders in pneumatics, our experts have developed some of the most innovative ranges of energy saving products and activities for compressed air systems which will help you save money as well as helping in the fight to protect our environment. Filter Flow Switch If this sounds too good to be true, we ll be happy to share our energy efficiency knowledge and technology with you! Air distribution Filter We love energy-saving products that save money and help the environment! Air application

3 SMC Energy Saving How much air do you think is being wasted in compressed air systems used in Europe? According to some recent research there are now more than 30,000 production facilities in Europe using compressed air systems. In total, the estimated annual industrial electricity consumption in Europe is 400 TWh which is divided into three main energy related categories: Coolant, Compressed Air and Others. The electrical energy required to manufacture compressed air for these facilities accounts for around 0% of this total industrial consumption. In an average facility, 70% of the generated compressed air is used in air blow applications, 10% for actuation with the remaining 0% lost through leakage. Most compressed air users are unaware that their systems often offer poor energy efficiency and that by specifically focusing on these systems savings of between 5 50% are the norm. Air 0% Coolant 30% Other 50% Actuators 10% Air leakage 0% Air blow 70% Do you know how much money is being wasted? To put this figure into some perspective, if you assume that an average saving of 33% could be achieved thanks to more efficient compressed air systems (6 TWh) and that the average electricity cost is 0.09 /kwh, the total electrical energy savings in Europe in compressed air systems alone would account for a staggering:,340 million euros And, in addition to these savings we will also stop 10.5 million tons of CO being released into the atmosphere! So, if you use compressed air in your manufacturing or production facilities, we have energy saving solutions and products to help you reduce your energy consumption thereby saving you money and maximising your energy efficiency. 3

4 SMC Energy Saving Software and Top Tips SMC's Energy Saving Software Energy Saving Software v.3.1b Every possible calculation related to Energy saving in compressed air Systems, for maximising the efficiency of your system. But also in simple applications you can calculate how much money you can save but using our ''start'' energy saving products. VMG calculator VXE calculator ASR/ASQ calculator And for correct sizing of your pneumatic circuit, don't forget to use our Model Selection Software. Ten top tips from our compressed air system (CAS) design experts Reduce the air pressure to the minimum requirement Size the pneumatic components for the actual performance needs Filter and dry air in an appropriate way Use only quality products Isolate the plant when not in use using port valves Stop air blow when not needed Generate vacuum using multi-stage ejectors with vacuum switches Where possible select low energy consuming components Periodically check the air consumption Prevent and reduce air leaks 4

5 SMC Energy Saving Audits SMC Energy Saving Audits Reason for improvement Recognise the potential of improvement As the world leaders in pneumatics, we can provide a specific service for compressed air users aimed at helping achieve maximum energy efficiency. Throughout Europe our highly trained Energy Saving Teams are on standby to study your complete installation from compressor control to actuator efficiency to detect any leakages and poor performance issues. This in-depth evaluation includes: Measurement Recognise current consumption Improvement Measurement Verify the enegy consumption after the improvement Energy savings Inefficient Compressor Control Air blow Leakages Pressure Levels Intermittent Demands General Air Consumption Our specialists will monitor your current consumption and evaluate all leakages, using a full range of measuring equipment and checks including: Flow, Pressure and Dew Point Monitors/Checks Data Loggers Filtration and Air Quality Checks Ultrasonic Leak Detection Infrared Temperature Guns Once the system has been thoroughly checked from top- to- bottom, our Energy Saving experts will provide a comprehensive evaluation of your compressed air system. This audit includes the following: In-depth report of the existing compressed air system Measurement and Findings Improvement Proposals Expected Savings Return on Investment Calculations System Maintenance Recommendations And unlike the majority of consultants who will only give you reports and recommendations, our SMC Energy Saving Teams will work with you and your people to help deliver these practical energy saving solutions with guaranteed results of building energy efficiency in your business. If you re interested in hearing more about our SMC Energy Saving Audits simply check out our dedicated Energy Saving web site on: or contact your local subsidiary for more information. 5

6 SMC FLOW SWITCH RESET SET UNIT SMC FLOW SWITCH RESET SET UNIT SMC FLOW SWITCH RESET SET UNIT SMC Energy Saving Products Index 1 Low Consumption Solenoid Valves Energy saving type port solenoid valve Series VXE Master solenoid valve M/C Pressure and Flow Monitoring Digital flow switch -colour display digital flow switch Differential pressure gauge Multi-channel controller for detecting differential pressure Series PFA Series PFM GD PSE01-X101 3 Air Blow Blow gun Air nozzle Series VMG Series KN Air blow Air gun 4 Pressure boosters Booster regulator Series VBA Heavy Booster Regulator + Air Tank 5 Energy Saving Cylinders and Accessories Non-rotating double power cylinder Series MGZ Pressure valve / flow valve Series ASR / Series ASQ Compact cylinder with solenoid valve Series CVQ Lifter 6 Vacuum Equipment Multistage ejector Vacuum pad with check valve Vacuum ejectors with check valve Series ZL INO-3769 Special order product Series ZM Special order product Suction transfer 6

7 1 Low Consumption Solenoid Valves Purpose Reduction of solenoid valves electricity consumption. For VXE Series power consumption is reduced down to 1/3 with respect to VX Series. A built-in power-saving circuit (based on the Pulse Width Modulation method) allows same performance with reduced energy consumption. Before improvement After improvement Energy Saving Type Port Solenoid Valve Series VXE Energy saving type of the VX, VXD and VXZ port solenoid valve series (replaceable coil). Coil heat reduction. Single and manifold options available. For various fluids and variety of sizes. Applicable voltages: 4 and 1 V DC. Voltage is applied to the coil during the whole ON regime of the valve, even during holding. The power consumption required to hold the solenoid in the ON position is optimised. Hence, less energy is consumed. Series VXE Direct operated type VXE110-01F-5DO1 VXE10-0F-5DO1 VXE30-0F-5DO1 VXE40-03F-5DO1 VXE350-03F-5DO1 VXE360-04F-5DO1 Series VXED Pilot operated type VXED130-0F-5DO1 VXED140-03F-5DO1 VXED140-04F-5DO1 VXED150-06F-5DO1 VXED60-10F-5DO1 coil voltage coil voltage coil current Series VXEZ Zero differential pressure pilot operated type VXEZ30-0F-5DO1 VXEZ30-03F-5DO1 VXEZ40-04F-5DO1 VXEZ350-06F-5DO1 VXEZ360-10F-5DO1 Orifice size [mm] Port size G1/8" G1/4" G3/8" G1/" G1/4" G3/8" G1/" G3/4" G1" G1/4" G3/8" G1/" G3/4" G1" start start Rated voltage + Electrical entry hold hold 4 V DC, for DIN terminal (without connector, with gasket), with built-in surge voltage supressor circuit 4 V DC, for DIN terminal (without connector, with gasket), with built-in surge voltage supressor circuit 4 V DC, for DIN terminal (without connector, with gasket), with built-in surge voltage supressor circuit ON OFF ON OFF ON OFF 5 Port Solenoid Valve Series VQ/VQC 5 Port Solenoid Valve Series SY 5 Port Solenoid Valve Cassette Type Series SJ000/3000 Power comsumption: Standard: 0.4 W / High Pressure option (1MPa): 0.95 W Power comsumption: 0.35 W / 0.1 W (with energy saving circuit) Power comsumption: 0.15 W (with energy saving circuit) 7

8 Pressure and Flow Monitoring Purpose Pressure and flow rate maintenance. Before improvement Pressure and flow rate losses due to leaks or clogging of the elements are not controlled. This causes the compressor, pump, etc. to work harder with subsequent, unnecessary air consumption. After improvement Differential Pressure Gauge GD The effective use of measuring instruments optimises the installation performance. Regular maintenance of clogged elements is implemented by mounting (differential) pressure monitoring equipment in every line. Air leakage is also detected and controlled with flow switches. q Differential pressure gauge GD q Differential pressure gauge Digital Flow Switch Series PFA For air. Simple, LED display readout. Either integrated or remote combination of sensor and display. Key pad for simple adjustments. independent outputs/switch points. No mechanically moving parts, so longer service life channel Flow Monitor Series PFD0 3 Integrated type PFA710-F01-67N PFA710-F0-67N PFA750-F01-67N PFA750-F0-67N PFA711-F03-67N PFA71-F03-67N PFA751-F04-67N PFA703H-F10-69N PFA706H-F14-69N PFA71H-F0-69N Remote type PFA510-F01N PFA510-F0N PFA550-F01N PFA550-F0N PFA511-F03N PFA51-F03N PFA551-F04N PFA301-A PFA311-A IN Upstream side Flow rate (l/min) 1 ~ 10 1 ~ 10 5 ~ 50 5 ~ ~ ~ ~ ~ ~ ~ 1000 Flow rate (l/min) 1 ~ 10 1 ~ 10 5 ~ 50 5 ~ ~ ~ ~ ~ ~ 500 Accessory Cable/plug with ferrite core Straight ZS-9-A Min. set unit (l/min) Type Measuring sensor Display OUT Downsteam side Switch outputs x PNP 80 ma 1 x PNP 80 ma Analogue: 4 ~ 0 ma Switch outputs x PNP, 80 ma q Digital flow switch for air Supply voltage 1-4 VDC 4VDC Supply voltage 1-4 VDC q Operating pressure range -50 kpa ~ 0.5 MPa -50 kpa ~ 0.75 MPa 0.1 ~ 1.5 MPa Operating pressure range -50 kpa ~ 0.5 MPa -50 kpa ~ 0.75 MPa Equipment Equipment Equipment

9 -Colour Display Digital Flow Switch Series PFM Integrated type Flow rate Dry air, N, Ar Flow rate CO Supply voltage Operating pressure range PFM710 * - ** - *** PFM75 * - ** - *** PFM750 * - ** - *** PFM711 * - ** - *** 0. to 10 l/min 0.5 to 5 l/min 1 to 50 l/min to 100 l/min 0. to 5 l/min 0.5 to 1.5 l/min 1 to 5 l/min to 50 l/min 4 V DC -100 kpa to 750 kpa Remote type Flow rate Dry air, N, Ar Flow rate CO Supply voltage Operating pressure range For air, N, Ar and CO. A digital flow switch that uses a MEMS sensor for detecting the flow. Compact size. Improved visibility with two colour display indication. Two piping directions are possible. Integrated flow adjustment valve. Multiple mounting combinations. PFM510 * - ** - PFM55 * - ** - PFM550 * - ** - PFM511 * - ** - PFM5 - Output specification Analogue output (4 to 0 ma) * Flow adjustment valve - Without flow adjustment valve S With flow adjustment valve *** PFM7 - Output specification Multi-Channel Controller for Detecting Differential Pressure PSE01-X101 B E F Accesories ZS-33-D ZS-33-F ZS-33-M ZS-33-MS ZS-33-J ZS-33-JS ZS-33-R* PNP outputs 0. to 10 l/min 0.5 to 5 l/min 1 to 50 l/min to 100 l/min 1 PNP output + Analogue (1 to 5 V) 1 PNP output + Analogue (4 to 0 ma) Lead wire with connector ( m) Lead wire with connector ( m) + rubber coverfor connector Bracket (for without adjustment flow valve ) Bracket (for with adjustment flow valve ) Panel mount adapter (for without adjustment flow valve ) Panel mount adapter (for with adjustment flow valve ) DIN rail mounting bracket *=number of stations (1 to 5) 0. to 5 l/min 0.5 to 1.5 l/min 1 to 5 l/min to 50 l/min ** Port size (straight piping) Symbol F01 F0 C4 C6 C8 PFM313-LF PFM314-LF Description Flow sensor monitor Part number 4 V DC -100 kpa to 750 kpa G1/8'' G1/4'' ø4 one-touch fitting ø6 one-touch fitting ø8 one-touch fitting Input specification Current input Flow rate range Current input Output specification PNP + 1 to 5 V outputs PNP + 4 to 0 ma outputs Accesories ZS-8-B Bracket ZS-7-C Panel mount adapter Panel mount adapter + front ZS-7-D protective cover ZS-8-C-1 Sensor connector PSE01-X101 Accesories ZS-8-C ZS-6-B ZS-6-C E-con connector for sensor (1pc) Panel mount adapter Panel mount adapter with front protective cover 9

10 3 Air Blowing Purpose Reduction of pressure consumption when air blowing. Effect of Energy Saving Improvement Pressure loss Min. Reduction Before After Before improvement After improvement S 0 to S 1 Effective area ratio 0.69 : 1 S Conventional coupler model Conventional coil tube model Air gun Nozzle ø3 S 0 to S 1 Effective area ratio 3.04 : 1 S Filter regulator S coupler Coil tube VMG Nozzle ø.5 Factory air line pressure is used directly. With VMG blow guns, pressure loss is reduced in the air flow direction. Adding a KN nozzle, the effective area ratio with the upstream side is improved (increased), hence pressure loss is reduced. Equipment Effective area Blow Gun Series VMG Coupler Piping Air gun Coupler, Piping (S 0 ) Air gun (S 1 ) Nozzle (S ) Effective area ratio (S 0 to S 1 :S ) Impact pressure Regulator pressure Pressure inside nozzle Compressor pressure Air consumption Electricity consumed by compressor Before improvement Conventional model Conventional coil tube model (I.D. ø5, equivalent length 5 m) Conventional model (Nozzle size ø3) 6.8 mm 6 mm 6.3 mm 0.69 : MPa (at a distance of 100 mm) 0.5 MPa 0.76 MPa 0.6 MPa 87 dm 3 /min (ANR) 1.56 kw Piping direction Port thread After improvement S coupler TCU X6 VMG (Nozzle size ø.5) mm 30 mm 4.4 mm 3.04 : MPa (at a distance of 100 mm) 0.4 MPa MPa 0.5 MPa 57 dm 3 /min (ANR) 1.5 kw Colour Operating pressure range (MPa) Ergonomically designed body with patented valve design and KN nozzles produces considerably reduction in pressure losses. connection options. Minimum actuation force required. Air Nozzle Series KN Male Thread Nozzle VMG11BU-F0 VMG11BU-F03 VMG11W-F0 VMG11W-F03 VMG1BU-F0 VMG1BU-F03 VMG1W-F0 VMG1W-F03 Nozzle-Ø Bottom Top Piping thread Low Noise Nozzle G1/4'' G3/8'' G1/4'' G3/8'' G1/4'' G3/8'' G1/4'' G3/8'' Blue White Blue White 0-1,0 Nozzle-Ø Piping thread KN-R0-100 KN-R0-150 KN-R0-00 KN-R ,5,5 KNS-R KNS-R KNS-R KNS-R ø0.75 x 4 ø0.9 x 8 ø1 x 4 ø1.1 x 8 Long Copper Pipe Nozzle Nozzle-Ø O.D. Length High Efficiency Nozzle Nozzle-Ø Piping thread 10 KNL KNL KNL KNL ,5 1, KNH-R0-100 KNH-R0-150 KNH-R ,5

11 4 Pressure Boosters Purpose Increase factory air pressure. Before improvement Force is insufficient due to low factory pressure. Increasing factory pressure is not efficient because of compressor energy consumption. After improvement Factory air pressure is increased up to twice with no need of an electrical supply. Boost pressure Heavy 0.3 MPa 0.6 MPa Factory line Booster Regulator + Air Tank 0.3 MPa 0.3 MPa Light Compressor 0.3 MPa Light Booster Regulator Series VBA Operating range (MPa) Flow rate (l/min) Port size Pressure ratio Circuit Symbol VBA11A-F0 VBA10A-F0 VBA0A-F03 VBAA-F03 VBA40A-F04 VBA4A-F04 VBA43A-F G1/4'' G3/8'' G1/'' max. 4 : 1 max. : 1 Increases the main circuit pressure to an adjustable value. Major energy savings. No other energy source required. Operating temperature: -50 C. Input pressure: MPa. Mounting position: horizontal. Improved service life: Floating piston structure and grease retaining groove. Improved reliability: Built-in mesh filter at IN port. Reduced noise. Accessories Model VBA10A-F0 VBA11A-F0 VBA0A-F03 VBAA-F03 VBA40A-F04 VBA43A-F04 VBA4A-F04 Pressure gauge G G KT-VBAA-7 G G Silencer AN0-0 AN30-03 AN40-04 High noise reduction ANA1-0 ANA1-03 ANA1-04 silencer Air tank VBAT10AF-SV-Q VBAT05AF-SV-Q VBAT0AF-RV-Q VBAT0AF-RV-Q VBAT10AF-SV-Q VBAT38AF-RV-Q VBAT38AF-RV-Q 11

12 5 Energy Saving Cylinders and Accessories Purpose Reduction of air consumption by actuators. Effect of Energy Saving Improvement Air 100% consumption 35% Reduction Before After Before improvement Non-optimised consumption of air in cylinders. After improvement Double Power Cylinder Series MGZ/MGZR Double-acting double power cylinder. Highly loadable as a result of integrated slide bearing. Non-rotating rod (MGZ) - by slide bearing with built-in non-rotating mechanism. Double extension output power by piston in piston construction. Approx. 30% reduced overall length compared with standard cylinders in tandem arrangement. Moment absorption is the same as guide cylinders (e.g. MGP), but with a 40% reduced overall width. Improved non-rotating accuracy: ±0,3 (±0,4 for ø0, 5). Optimum design by the use of profile tube, auto switch can be integrated in grooves. Simple piping connection via ports, resulting from internal air channels. Pre-cut mounting threads in cylinder covers and piston rod. The performance of a double power extension cylinder, series MGZ, requires lower operating pressure than a conventional cylinder. Air saving valves, series ASR and ASQ, enable a 40% reduction in air consumption. Also, compact solutions such as CVQ series, integrating a valve and a compact cylinder in one product, allow a considerable reduction in air consumption and piping requirements. MGZ0 - * MGZ5TF - * MGZ3TF - * MGZ40TF - * MGZ50TF - * MGZ63TF - * MGZ80TF - * MGZR0 - * MGZR5TF - * MGZR3TF - * MGZR40TF - * MGZR50TF - * MGZR63TF - * MGZR80TF - * Ø Standard strokes 75, 100, 15, 150, 175, 00, 50, 300 Long stroke version up to 1000 mm available (800 mm for ø0,ø5) Theoretical output, extension stroke (N) at 0,6MPa * Stroke length Mounting elements such as foot brackets, flanges on request Possible auto switches/accessories Type Reed switch 3-wire solid state PNP -wire solid state Auto switch spacer MGZ Ø 0, 5, 3 mm D-A93L, D-A90L D-M9PWL D-M9BWL BMY MGZ Ø mm D-A93L, D-A90L D-M9PWL D-M9BWL BMG-01 AB AB Cushion Rubber bumper Type With non-rotating mechanism Without non-rotating mechanism Port Size M5 G1/8'' G1/8'' G1/4'' G3/8'' M5 G1/8'' G1/8'' G1/4'' G3/8'' 1

13 Air Saving Valve Series ASR (Pressure Valve) Series ASQ (Flow Valve) 40% reduction in air consumption Pressure valve / Series ASR Integrated display type Applicable tubing O.D. Port size Pressure Valve Flow valve ASR430F-0- S ASR530F-0- S ASR530F-03- S ASR630F-03- S ASR630F-04- S ASQ430F-0- S ASQ530F-0- S ASQ530F-03- S ASQ630F-03- S ASQ630F-04- S : Add applicable tubing O.D. R1/4'' R1/4'' R3/8'' R3/8'' R1/'' Cuts air consumption by operating the return stroke at a reduced pressure. Conventional valve Working and return strokes operated at the same pressure Air saving valve Return stroke operated at a reduced pressure Pressure valve Flow valve Flow valve / Series ASQ Working stroke Return stroke Working stroke Return stroke Working principle Cylinder performance comparison When a large load affects both lifting and lowering Pressure ON OFF Regulator with check valve Stroke Conventional circuit Air saving valve circuit Compact Cylinder with Solenoid Valve Series CVQ Bore size Port size ø Rated voltage Electrical entry CVQB3-*-5MO CVQB40-*-5MO * Stroke V DC M-type plug connector without connector Bore size 3 40 Standard stroke A double acting compact cylinder with integrated solenoid valve ( positions single solenoid type). Space, energy and labour saving. Improved response speed. Different piping directions are possible. Two sizes: ø3 and ø40 mm. Enclosure: IP40. 13

14 6 Vacuum Equipment Purpose Reduction of air consumption in vacuum applications. Before improvement Suction of a workpiece under leakage conditions requires large suction flow which, in turn, demands the use of a larger nozzle and increased air consumption. After improvement Vacuum Ejector Series ZL Compact design. 3 different types: Ejector + vacuum switch. Ejector + vacuum gauge. Only ejector Vacuum built by 3 stage ejector therefore less air consumption, by the nozzle. Nozzle diameter 1. mm. Suction capacity 100 l/min or 00 l/min with ZL1. Different ways of fixing to body. The use of a 3-stage ejector, Series ZL, enables the reduction of air consumption even under the same suction flow and vacuum pressure conditions. INO vacuum pads with valve enable suction of the workpiece at the moment of contact with the pad and not previously, with the subsequent air consumption. Specials of the series ZM, vacuum ejector with check valve enable stopping air supply to maintain the suction of the workpiece. Air consumption is reduced by shortening the vacuum generation time. Nozzle Ø [mm] 1. x 1. Without casing Type number ZL11-Q ZL11-G-Q ZL11-DPL-Q ZL11-DNL-Q ZL11-DEL-Q ZL11-K15LOZ-DPL-Q ZL11-K15LOZ-DNL-Q ZL11-K15LOZ-DEL-Q ZL1-Q ZL1-G-Q ZL1-DPL-Q ZL1-DNL-Q ZL1-DEL-Q Type Standard Standard with vacuum pressure gauge Standard with vacuum switch Standard with vacuum switch and control valves Standard Standard with vacuum pressure gauge Standard with vacuum switch Switch output PNP NPN PNP + (1 5 V) PNP NPN PNP + (1 5 V) PNP NPN PNP + (1 5 V) Suction cap. (l/min) Max. Vacuum Pressure -84 kpa -84 kpa Cable L= 0.6 m Cable L= 1 m Cable L= m Cable L= 3 m SY A-6 SY A-10 SY A-0 SY A-30 Air consumption before and after using ZL Vacuum pressure (kpa) Nozzle size ø1.8 Air consumption 150 l/min Vacuum pressure (kpa) Nozzle size ø1. Air consumption 63 l/min Vacuum Working principle of a 3-stage vacuum ejector % increase in suction capacity Suction capacity Suction flow (l/min) 55 Suction flow (l/min)

15 Vacuum Pad with Check Valve Series INO-3769 Special Order Product The valve opens only when the pad end pin contacts the workpiece, and vacuum is generated. When multiple pads are used in the branch piping, vacuum level is not reduced even in case of vacuum failure or change in the workpiece size. INO CN INO CN INO CN INO CN-B01 INO CN-B01 INO CN-B01 INO UN INO UN INO US Pad diameter Ø, [mm] Pad shape Flat with ribs Flat Material NBR Silicon rubber Others Vacuum entry: Rc 1/8'' Vacuum Ejector with Check Valve Series ZM Special Order Product Nozzle diameter, Ø mm (H type only) mm (except S type) mm (except S type) mm mm (S type only) Body type Conforms to the standard product Standard supply pressure H 0.5 MPa M 0.35 MPa (except 15) S 0.45 MPa (13, 15 only) ZM ** 1 * -B5LZ-E**L-X14-Q CE marked Switch type Conforms to the standard product Electrical entry Conforms to the standard product Power supply voltage 4 V DC With N.O. air supply valve / N.O. type vacuum release valve Before using ZM - continuous supply of air is required Standard ejector Vacuum generation After using ZM - air consumption is reduced by shortening the vacuum generation time. Suction is achieved with no continuous supply of air. Ejector with check valve Ejector unit circuit Vacuum generation Vacuum holding Assumed to be sec. 80 kpa Workpiece 1.5 sec 0.5 sec Note) Since vacuum pressure may drop due to leakage, etc., use a pressure switch to maintain the vacuum pressure necessary for the suction of a work piece. 15

16 ES01A-UK SMC CORPORATION (Europe) Austria Belgium +3 (0) Bulgaria Croatia Czech Republic Denmark Estonia Finland France +33 (0) Germany +49 (0) Greece Hungary Ireland +353 (0) Italy +39 (0)9711 Latvia Lithuania Netherlands +31 (0) Norway Poland Portugal Romania Russia Slovakia Slovenia Spain Sweden +46 (0) Switzerland +41 (0) Turkey +90 (0) UK +44 (0) SMC CORPORATION Akihabara UDX 15F, , Sotokanda, Chiyoda-ku, Tokyo , JAPAN Phone: FAX: st printing LX printing MY 5 Printed in Spain Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.

SMC Solutions for the measurement, removal and control of static electricity

SMC Solutions for the measurement, removal and control of static electricity SMC solutions for static electricity: Ionizers Benefits: Reduced production costs Improved efficiency in production performance, with increased production speed Safety increased, with improved safer machine

More information

SMC solutions for static electricity: Ionizers. SMC Solutions for the measurement, removal and control of static electricity.

SMC solutions for static electricity: Ionizers. SMC Solutions for the measurement, removal and control of static electricity. SMC solutions for static electricity: Ionizers SMC Solutions for the measurement, removal and control of static electricity Quick Overview Reduce production costs, improve production performance, increase

More information

ISO Cylinders. ISO Cylinders. Wide range and fast delivery

ISO Cylinders. ISO Cylinders. Wide range and fast delivery ISO Cylinders ISO Cylinders Wide range and fast delivery WIDE RANGE: Our ISO Cylinders take standardisation to another level SMC presents you our full range of standardscomplying cylinders: tierod, compact

More information

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100. Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.

More information

Compact Cylinder ISO Standards [ISO/21287]

Compact Cylinder ISO Standards [ISO/21287] Compact Cylinder ISO Standards [ISO/2] New It is possible to mount small auto switches on surfaces. es can be mounted on any of the surfaces, depending on the installation conditions. Improved flexibility

More information

LCD Readout Digital Pressure Switch

LCD Readout Digital Pressure Switch LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display RoHS Can be integrated with a vacuum unit, Series

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders

More information

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range. 2-Color Display High-Precision Digital Pressure Switch Series ZSE3A(F)/ISE3A RoHS Can copy to up to 1 switches simultaneously. The settings of the master sensor can be copied to the slave sensors. Reducing

More information

ISO/VDMA Actuators. Engineering GREAT Solutions

ISO/VDMA Actuators. Engineering GREAT Solutions ISO/VDMA Actuators Engineering GREAT Solutions 02 ISO/VDMA Actuators Contents 03 Introduction 04 ISO/VDMA Actuators 06 The ISO/VDMA Range 08 Industrial Options 10 Cleanline Options 12 IVAC innovation to

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 2 HYDRAULIC AND PNEUMATIC CYLINDERS The material needed for outcome 2 is very extensive

More information

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA USER S MANUAL FH052EAV1 FH070EAV1 E HNIKA PORTUGUÊS ENGLISH ESPAÑOL ITALIANO DEUTSCH FRANÇAIS System Air Conditioner (Cooling and Heating) E S F I P D G DB98-29263A(1) Safety Precautions Register your

More information

APPLIED PNEUMATICS AND HYDRAULICS H TUTORIAL HYDRAULIC AND PNEUMATIC CYLINDERS. This work covers part of outcome 2 of the standard Edexcel module.

APPLIED PNEUMATICS AND HYDRAULICS H TUTORIAL HYDRAULIC AND PNEUMATIC CYLINDERS. This work covers part of outcome 2 of the standard Edexcel module. APPLIED PNEUMATICS AND HYDRAULICS H TUTORIAL HYDRAULIC AND PNEUMATIC CYLINDERS This work covers part of outcome 2 of the standard Edexcel module. The material needed for outcome 2 is very extensive so

More information

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S. Electro-Pneumatic Proportional Valve Series /VEP Electro-pneumatic proportional valve: Flow type () Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

HSeries. High Power High Quality. Ultra-High Speed, Sensing Ionizer SJ-H Series

HSeries. High Power High Quality. Ultra-High Speed, Sensing Ionizer SJ-H Series NEW Ultra-High Speed, Sensing Ionizer SJ-H Series High Power High Quality Suitable for high-speed static elimination in wide areas, including clean room environments HSeries The highest static elimination

More information

Pressure transmitter (2 wire) / switch for continuous or On/Off Control

Pressure transmitter (2 wire) / switch for continuous or On/Off Control transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Kompressoren. Adsorption Dryer AD

Kompressoren. Adsorption Dryer AD Kompressoren Adsorption Dryer AD Adsorption Drying: why? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated

More information

ERASMUS+ MASTER LOANS

ERASMUS+ MASTER LOANS ERASMUS+ MASTER LOANS Erasmus+ Master Loan: opening up access to more affordable lending for cross-border studies The Erasmus+ programme makes it possible for students who want to take a full Masters level

More information

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

AIR-AIR PRESSURE MULTIPLIER (BOOSTER) AIR-AIR PRESSURE MULTIPLIER (BOOSTER) The air-air pressure multiplier, or booster, is an automatic device that compresses air to give an outlet pressure that is double the inlet pressure. It is normally

More information

Electro-Pneumatic Bus Door Control Mechanism

Electro-Pneumatic Bus Door Control Mechanism Electro-Pneumatic Bus Door Control Mechanism Application and Feature 1. Pneumatic Door Mechanism actuates the open/close movements of bus door through two double acting cylinders and two linkages with

More information

TOYOTA I_SITE More than fleet management

TOYOTA I_SITE More than fleet management EMPOWERING YOUR BUSINESS TOYOTA I_SITE More than fleet management www.toyota-forklifts.eu TOYOTA I_SITE More than fleet management Toyota I_Site is a unique combination of technology, information, expertise

More information

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40 Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane

More information

Automatic control equipment for HVAC systems

Automatic control equipment for HVAC systems Automatic control equipment for HVAC systems Products for domestic and industrial installations In buildings, the main aim of the installations is to guarantee and maintain a comfortable ambient. Watts

More information

Valves for Safety Applications

Valves for Safety Applications Valves for Safety Applications Inherently fail-safe Dynamic self-monitoring No residual pressure Large exhaust capacity World-wide Safety Approvals ESSENTIAL PRINCIPLES Basic features of safety valves

More information

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3 Port Solenoid Valve 00/00/00 Metal Seal Rubber Seal 0. 0.9 (Standard) (High pressure type, High speed response type) Power consumption: 0. W/0.9 W Compact, High Flow Body ported Base mounted 00 00 00 00

More information

ERASMUS+ MASTER LOANS

ERASMUS+ MASTER LOANS Ref. Ares(2015)660570-17/02/2015 ERASMUS+ MASTER LOANS Erasmus+ Master Loan: opening up access to more affordable lending for cross-border studies The Erasmus+ programme makes it possible for students

More information

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar. CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension

More information

13 th Economic Trends Survey of the Architects Council of Europe

13 th Economic Trends Survey of the Architects Council of Europe 13 th Economic Trends Survey 13 th Economic Trends Survey of the Architects Council of Europe 13 th Economic Trends Survey Breakdown of responses COUNTRY ANSWERS France 1464 Belgium 399 Spain 365 Italy

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive

More information

4/2-Way Pneumatic Solenoid Valve

4/2-Way Pneumatic Solenoid Valve 4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug

More information

RoHS. Ready. Quick Reference Guide DYNAMIC Series. te.com/products/dynamicseries PRODUCT APPLICATIONS

RoHS. Ready. Quick Reference Guide DYNAMIC Series. te.com/products/dynamicseries PRODUCT APPLICATIONS Quick Reference Guide DYNAMIC Series Dynamic Series is a broad product family that provides connector solutions ranging from signal level circuitry through power circuit connectivity in a ruggedized, industrialized

More information

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB98-29565A(1) ENGLISH ESPAÑOL

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB98-29565A(1) ENGLISH ESPAÑOL USER S MANUAL Duct Type Series MH MH FEEA Series FUEA Series ENGLISH ESPAÑOL PORTUGUÊS E HNIKA DEUTSCH ITALIANO FRANÇAIS Free Joint Multi Air Conditioner (Cooling and Heating) E S F I P D G DB98-29565A(1)

More information

Safety Relay Units. G9SR family. Diagnosis with LEDs Selectable operating modes and times Increased extension possibilities. industrial.omron.

Safety Relay Units. G9SR family. Diagnosis with LEDs Selectable operating modes and times Increased extension possibilities. industrial.omron. Safety Relay Units G9SR family Diagnosis with LEDs Selectable operating modes and times Increased extension possibilities industrial.omron.eu/g9sr ... A complete standalone Safety Relay Unit family - G9SR

More information

M8 / M12 CONNECTOR SYSTEM

M8 / M12 CONNECTOR SYSTEM M8 / M12 CONNECTOR SYSTEM EVERY CONNECTION COUNTS TE CONNECTIVITY S M8 / M12 Connector System for machine industrial automation and control applications provides a solution that safely and reliably ensures

More information

Energy prices in the EU Household electricity prices in the EU rose by 2.9% in 2014 Gas prices up by 2.0% in the EU

Energy prices in the EU Household electricity prices in the EU rose by 2.9% in 2014 Gas prices up by 2.0% in the EU 92/2015-27 May 2015 Energy prices in the EU Household electricity prices in the EU rose by 2.9% in 2014 Gas prices up by 2.0% in the EU In the European Union (EU), household electricity prices 1 rose by

More information

Vacuum Module: Series ZX Vacuum Ejector System/External Vacuum Supply System

Vacuum Module: Series ZX Vacuum Ejector System/External Vacuum Supply System Module: Series ZX Ejector System/External Supply System ZX ZR ZM Suitable for handling electronic components and precision components up to 100g Modular Design Customized application function through selection

More information

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Control- and feedback head for integrated mounting on Robolux valves Type 2036 Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated

More information

Accuracy counts! SENSORS WITH ANALOG OUTPUT

Accuracy counts! SENSORS WITH ANALOG OUTPUT Accuracy counts! SENSORS WITH ANALOG OUTPUT OTHER APPLICATIONS: KEY ADVANTAGES: Distance measurement Positioning Profile detection Deformation monitoring Vibration monitoring Process monitoring Detection

More information

Program Summary. Fluid & Motion Control Filtration & Fluid Management Sensors & Measurement

Program Summary. Fluid & Motion Control Filtration & Fluid Management Sensors & Measurement Program Summary Fluid & Motion Control Filtration & Fluid Management Sensors & Measurement 2 Table of content Content Fluid & Motion Control 3 Directional Control Valves, solenoid operated 4 Directional

More information

MANTA Piston Distributor for Oil and Fluid Grease

MANTA Piston Distributor for Oil and Fluid Grease MANTA Piston Distributor for Oil and Fluid Grease Function Piston distributors meter out and distribute the oil delivered by an intermittently actuated pump. The quantities of oil for the individual lube

More information

Micro cogeneration. Affordable, efficient and innovative

Micro cogeneration. Affordable, efficient and innovative Micro cogeneration Affordable, efficient and innovative A compact and efficient solution A compact and efficient solution Organisations are increasingly looking for environmentally friendly systems to

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual Doc.No. NDP 192U-02 Electric Pump Controller CE-124P Instruction Manual 1. Parts Name and Function 1) POWER LED Indicate that CE-124P is powered up. 2) START/STOP KEY (SELECTOR KEY) Used to start and stop

More information

International Hints and Tips

International Hints and Tips International Hints and Tips Content Q: What is the cut off time for processing International payments? A: International payments must be submitted and fully approved within the cut off time indicated

More information

Order Code for GEA Tuchenhagen VESTA Sterile Valves. Type H_A 2/2 Way Seat Valve

Order Code for GEA Tuchenhagen VESTA Sterile Valves. Type H_A 2/2 Way Seat Valve Order Code for VESTA Sterile Valves Type H_A 2/2 Way Seat Valve engineering for a better world GEA Mechanical Equipment VESTA Sterile Valves are designed for universal use in sterile process technology.

More information

Labour Force Survey 2014 Almost 10 million part-time workers in the EU would have preferred to work more Two-thirds were women

Labour Force Survey 2014 Almost 10 million part-time workers in the EU would have preferred to work more Two-thirds were women 75/2015-27 April 2015 Labour Force Survey 2014 Almost 10 million part-time workers in the EU would have preferred to work more Two-thirds were women Among the 44.1 million persons in the European Union

More information

Vacuum system components

Vacuum system components This is appropriate for high speed transfer such as electric part, compact precision part Vacuum system components VSN/VSNP Series VACUUM SYSTEM COMPONENTS SELVACS VSN/VSNP SERIES CC967A Appropriate for

More information

To install the I/O Module Board: 1. Remove AC power from decoder.

To install the I/O Module Board: 1. Remove AC power from decoder. Installation Data (Catalog Number 2755-NB0, -NB1, -NB2) This document shows how to install the following components in the 2755-DSxx ➀ and 2755-DDxx ➀ Bar Code Decoders. I/O Module Board (Catalog No. 2755-NB1

More information

Diesel Generating Set

Diesel Generating Set MODEL Standby Power(50Hz) Prime Power(50Hz) 44KW /55KVA 40KW /50KVA Standard Features General Features: Engine( DCEC Cummins 4BTA3.9 -G) Radiator 40 O C max,fans are driven by belt, with safety guard 24V

More information

Electricity, Gas and Water: The European Market Report 2014

Electricity, Gas and Water: The European Market Report 2014 Brochure More information from http://www.researchandmarkets.com/reports/2876228/ Electricity, Gas and Water: The European Market Report 2014 Description: The combined European annual demand for electricity,

More information

41 T Korea, Rep. 52.3. 42 T Netherlands 51.4. 43 T Japan 51.1. 44 E Bulgaria 51.1. 45 T Argentina 50.8. 46 T Czech Republic 50.4. 47 T Greece 50.

41 T Korea, Rep. 52.3. 42 T Netherlands 51.4. 43 T Japan 51.1. 44 E Bulgaria 51.1. 45 T Argentina 50.8. 46 T Czech Republic 50.4. 47 T Greece 50. Overall Results Climate Change Performance Index 2012 Table 1 Rank Country Score** Partial Score Tendency Trend Level Policy 1* Rank Country Score** Partial Score Tendency Trend Level Policy 21 - Egypt***

More information

www.ode.it THE COMPLETE SOLUTION for COFFEE MACHINES SOLENOID VALVES & PUMPS

www.ode.it THE COMPLETE SOLUTION for COFFEE MACHINES SOLENOID VALVES & PUMPS www.ode.it THE COMPLETE SOLUTION for COFFEE MACHINES SOLENOID VALVES & PUMPS THE CONCEPT OF QUALITY HAS ALWAYS BEEN PART OF ODE CULTURE AND MISSION. ODE is a leading company since 1960 in designing and

More information

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1 No. : EX##-OMF0004 OPERATION MANUAL EX12#-SMB1 Contents 1. Safety instructions ------------------------------------------------------ P3 2. Notes ------------------------------------------------------

More information

Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION

Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION photoelectric sensors Thanks to its vision for innovation and technological enhancement, Contrinex keeps on setting new standards

More information

ERMInE Database. Presentation by Nils Flatabø SINTEF Energy Research. ERMInE Workshop 2 - Northern Europe Oslo, 1. November 2006

ERMInE Database. Presentation by Nils Flatabø SINTEF Energy Research. ERMInE Workshop 2 - Northern Europe Oslo, 1. November 2006 ERMInE Database Presentation by Nils Flatabø SINTEF Energy Research ERMInE Workshop 2 - Northern Europe Oslo, 1. November 26 Overview Content of the Ermine Database Electronic Questionnaire RTD&D Data

More information

Material test chamber with mechanical convection

Material test chamber with mechanical convection FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and

More information

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to: OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND

More information

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47) 47 Brakes - Hydraulic Components (Page GR-47) FS III front brake calipers, servicing Front brake caliper piston, removing and installing FN 3 front brake calipers, servicing Front caliper piston, removing

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

On request of Akzo Nobel Dynamo Project Team we ve surveyed the energy efficiency of the compressed air system in the Barcelona Deco & A/AS plant.

On request of Akzo Nobel Dynamo Project Team we ve surveyed the energy efficiency of the compressed air system in the Barcelona Deco & A/AS plant. Postbus 9058 6070 AB Swalmen (NL) Akzo Nobel Car Refinishes S.L./Coatings S.L. Att. Mr. Cesar Franch Tel. +31(0)77-7676276 Fax +31(0)77-7676286 e.mail info@ants-tech.nl website www.ants-tech.nl cesar.franch@akzonobel.com

More information

Medical Air Systems: Scroll

Medical Air Systems: Scroll GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing

More information

The flexible performer: ALS 306

The flexible performer: ALS 306 The flexible performer: ALS 306 The new labelling generation for your efficient product identification The perfect fit For highly demanding brands... The power of brands People know your products. Your

More information

NEW PASSENGER CAR REGISTRATIONS BY ALTERNATIVE FUEL TYPE IN THE EUROPEAN UNION 1 Quarter 4 2015

NEW PASSENGER CAR REGISTRATIONS BY ALTERNATIVE FUEL TYPE IN THE EUROPEAN UNION 1 Quarter 4 2015 NEW PASSENGER CAR REGISTRATIONS BY ALTERNATIVE FUEL TYPE IN THE Quarter 4 2015 Alternative fuel vehicle (AFV) registrations: +20.0% in 2015; +21.1% in Q4 In the fourth quarter of 2015, total alternative

More information

Size and Development of the Shadow Economy of 31 European and 5 other OECD Countries from 2003 to 2015: Different Developments

Size and Development of the Shadow Economy of 31 European and 5 other OECD Countries from 2003 to 2015: Different Developments January 20, 2015 ShadEcEurope31_January2015.doc Size and Development of the Shadow Economy of 31 European and 5 other OECD Countries from 2003 to 2015: Different Developments by Friedrich Schneider *)

More information

Business Cooperation Database Profile Extraction

Business Cooperation Database Profile Extraction Business Cooperation Database Profile Extraction Produced the 23/05/2013 General Information Profile ID 20111230018 Summary Creation Date 30/12/2011 Last Update 12/01/2012 Expiration Date 02/01/2014 Intermediary

More information

Smart DeviceNet Remote I/O Terminals

Smart DeviceNet Remote I/O Terminals Smart DeviceNet Remote I/O Terminals ather and Use Information for Effective Preventive Maintenance et more useful data for preventive maintenance when you build cost-effective parallel information systems

More information

Compact cylinder Double acting single rod type. SSD SSD-L (with switch) Double acting Compressed air 1.0. 1.6-10 to 60 (no freezing) Rc1/8 Rc1/4 Rc3/8

Compact cylinder Double acting single rod type. SSD SSD-L (with switch) Double acting Compressed air 1.0. 1.6-10 to 60 (no freezing) Rc1/8 Rc1/4 Rc3/8 * U S 4 Specifications escriptions Bore size mm Actuation Working fluid ax. working pressure Pa in. working pressure Pa Withstanding pressure Pa Ambient temperature Port size Stroke length Rubber cushioned

More information

Waste. Copenhagen, 3 rd September 2014. Almut Reichel Project Manager Sustainable consumption and production & waste, European Environment Agency

Waste. Copenhagen, 3 rd September 2014. Almut Reichel Project Manager Sustainable consumption and production & waste, European Environment Agency Waste Copenhagen, 3 rd September 2014 Almut Reichel Project Manager Sustainable consumption and production & waste, European Environment Agency Waste and material resources MAWP Strategic Area 1.9 Objective

More information

PRODUCT PROFILE FEATURES

PRODUCT PROFILE FEATURES PRODUCT PROFILE Pressure Transmitters & Pneumatic Transducer Airflow Transmitter, Differential Air Pressure Transmitter and Differential & Gauge Liquid/Gas Pressure Transmitter FEATURES AIRFLOW TRANSMITTER

More information

Proximity Switches RS (Reed Switch)

Proximity Switches RS (Reed Switch) Proximity Switches RS (Reed Switch) General Pneumatic systems can often be combined with electric control circuits. The position of the piston in the cylinder can then be sensed by means of a proximity

More information

HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL)

HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL) HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL) The oil level regulator controls the oil level in the compressor crankcase with a float operated valve. Oil level regulators are designed to attach

More information

OPL BASIC. Dosing System for Professional Laundry machines. Contents

OPL BASIC. Dosing System for Professional Laundry machines. Contents OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page

More information

it500 Internet Thermostat INSTALLER MANUAL

it500 Internet Thermostat INSTALLER MANUAL it500 Internet Thermostat INSTALLER MANUAL 1. Product compliance & safety information These instructions are applicable to the SALUS Controls model stated on the front cover of this manual only, and must

More information

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Visions become real. Temperature control and cooling systems. The innovative and reliable solution Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature

More information

European Rack and Rack Options Market

European Rack and Rack Options Market Brochure More information from http://www.researchandmarkets.com/reports/2701935/ European Rack and Rack Options Market Description: The European rack and rack options market is growing with still high

More information

BEST PRACTICES/ TRENDS/ TO-DOS

BEST PRACTICES/ TRENDS/ TO-DOS Online Insurance Europe: S/ TRENDS/ TO-DOS New success guidelines WHAT TO DO N D E EW IO IT N Your Benefits EUROPE S S/ TRENDS/ TO-DOS: The new and only study about the best online insurance solutions

More information

TMS TANK MANAGEMENT SYSTEM

TMS TANK MANAGEMENT SYSTEM TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS

More information

Computing our Future Computer programming and coding in schools in Europe. Anja Balanskat, Senior Manager European Schoolnet

Computing our Future Computer programming and coding in schools in Europe. Anja Balanskat, Senior Manager European Schoolnet Computing our Future Computer programming and coding in schools in Europe Anja Balanskat, Senior Manager European Schoolnet ABOUT THE SURVEY What do Ministries currently think about the topic? Curricula

More information

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics

More information

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK CL - CH - CK Direct driven solution for industry Proven technology, solid construction The CL - CH - CK units are directly driven air-cooled, single

More information

Series IZS31 Technical Data 1

Series IZS31 Technical Data 1 Series IZS Technical Data Static electricity Removal Characteristics Note) Static electricity elimination features are based on data from using a charged plate (size: mm x mm, capacitance: pf) as defined

More information

ERASMUS+ MASTER LOANS

ERASMUS+ MASTER LOANS ERASMUS+ MASTER LOANS Erasmus+ Master Loan: opening up access to more affordable lending for cross-border studies The Erasmus+ programme makes it possible for students who want to take a full Master's-level

More information

Adsorption air dryers ADS 1 215

Adsorption air dryers ADS 1 215 Adsorption air dryers ADS 25 INDUSTRY CUSTOMER SERVICE COMPRESSED AIR AIR INTAKE 20 C 70% UR 760 mm Hg 2 grh 2 O/m 3 AIR PRESSURE 0 bar COOLING SYSTEM 30 C 00% UR 0 bar 2,8 grh 2 O/m 3 A compressor that

More information

1. Perception of the Bancruptcy System... 2. 2. Perception of In-court Reorganisation... 4

1. Perception of the Bancruptcy System... 2. 2. Perception of In-court Reorganisation... 4 Bankruptcy Systems and In-court Reorganisation of Firms, 2010 Content: 1. Perception of the Bancruptcy System... 2 2. Perception of In-court Reorganisation... 4 3. Perception of Creditor Committees, Fast

More information

The future electrical opening system for skylights, smoke hatches and windows

The future electrical opening system for skylights, smoke hatches and windows The future electrical opening system for skylights, smoke hatches and windows Actulux A/S Background and Visions Actulux develops, produces and distributes innovative electrical opening systems for skylights,

More information

FDH Series Compact Finger Slides

FDH Series Compact Finger Slides FDH Series Compact Finger Slides Catalog #FDH- Prices effective September 1, 11 Cylinder block- Clear anodized aluminum Top Toolplate and Front Toolbar Clear anodized aluminum Tapped mounting holes ( for

More information

Workshop Compressors CLASSIC Series

Workshop Compressors CLASSIC Series www.kaeser.com Workshop Compressors CLASSIC Series Displacement: 210 to 40 l/min Pressure: 10 bar What do you expect from your CLASSIC workshop compressor? Quality results can be achieved only by using

More information

VALVES ISO 5599/1 SERIES SAFE AIR

VALVES ISO 5599/1 SERIES SAFE AIR Starting from a series of sturdy, reliable valves, such as those to ISO 5599/1, some special features have been added, such as the presence of a valve status diagnostic system and the creation of a double

More information

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05 D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05 GENERAL SECTION PAGE MOOG SERVO- AND PROPORTIONAL CONTROL VALVES General 2 enefits and Functionality 3 General

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

Universal type. Elbow type AS13 1FG-M5 AS23 1FG-01 AS23 1FG-02 AS33 1FG-02 AS33 1FG-03 AS43 1FG-04. Specifications

Universal type. Elbow type AS13 1FG-M5 AS23 1FG-01 AS23 1FG-02 AS33 1FG-02 AS33 1FG-03 AS43 1FG-04. Specifications Speed Controller with One-touch Fitting Stainless Steel Series Elbow Type/Universal Type Series -FG RoHS Stainless specifications for use in corrosive environments. Stainless steel used for metal parts.

More information

Hydraulic Control Solutions

Hydraulic Control Solutions Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal ort Solenoid Valve Series SYJ00/00/700 [Option] SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M.

More information

Extract of the White paper Reduce energy costs in compressed air systems by up to 60%

Extract of the White paper Reduce energy costs in compressed air systems by up to 60% Extract of the White paper Reduce energy costs in compressed air systems by up to 60% How can potential energy savings be identified? There are various measures for realising potential savings in compressed

More information

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding

More information

Steering unit. Table of contents. Features RE 11872/05.06. Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Steering unit. Table of contents. Features RE 11872/05.06. Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min Steering unit RE 11872/05.06 /10 Type LAGL Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min H7375 Table of contents Contents Page Features 1 Ordering code 2 Function, section 3 Device

More information

About us. As our customer you will be able to take advantage of the following benefits: One Provider. Flexible Billing. Our Portal.

About us. As our customer you will be able to take advantage of the following benefits: One Provider. Flexible Billing. Our Portal. About us At RoamingExpert we specialise in mobile roaming tariffs which are tailored to the specific needs of the yachting industry. Our unique offering generates significant savings when compared to standard

More information