ClearPath MCP Software Series Compatibility Guide

Size: px
Start display at page:

Download "ClearPath MCP Software Series Compatibility Guide"

Transcription

1 ClearPath Software Series Compatibility Guide Overview The ClearPath Software Series is designed to deliver new cost and performance competitive attributes and to continue to advance environment attributes by enabling fast implementation of client application modernization initiatives. By packaging the operating environment as a software only solution, clients are able to deploy onto platforms of their own choosing. This Compatibility Guide describes the system requirements for ClearPath Software Series products and provides guidelines for their use. Product Specific Information This section describes the currently supported configurations for each product in the ClearPath Software Series. As new products are added to the series their characteristics will be included in this document. ClearPath Developer Studio System Type: DE1000 or GE1000 When the ClearPath Forward fabric version of Developer Studio is ordered and installed over s-par on a PEPP (Partitionable Enterprise Partition Platform), the system identifies itself as a DE1000. When a hardware-independent version of Developer Studio is ordered and installed on Bare Metal or over a qualified non-unisys hypervisor, the system identifies itself as a GE1000. The following table defines the attributes of a Developer Studio partition. s-par 1 or 2 VMware 1 or 2 Bare Metal 1 or 2 Disk or VSS1/VSS2 Tape DVD or VSS1/VSS2 Here are recommendations for various size attributes for Developer Studio for the minimum allowable configuration and one which comfortably supports larger configurations. # of Intel Logical Minimum 2 (1 CPM) (2 CPM) Unisys Corporation Page 1 June 2016

2 ClearPath Developer Studio Personal Edition System Type: DE1000 ClearPath Developer Studio Personal Edition is a single user development environment qualified for use on a client provided Reference Architecture computer. The following table defines the attributes of the Developer Studio Personal Edition partition. Bare Metal 1 or 2 Disk or VSS1/VSS2 Tape DVD Windows 7 SP1 Windows 8.1 Here are recommendations for various size attributes for Developer Studio Personal Edition for the minimum allowable configuration and one which comfortably supports larger configurations. # of Intel Logical Minimum 2 (1 CPM) (2 CPM) ClearPath Bronze System Type: GE0500 ClearPath Bronze is a production level environment qualified for use on a client provided Reference Architecture computer utilizing either Bare Metal or a hypervisor. ClearPath Bronze is a general purpose offering for environments having modest capacity requirements. The following table defines the attributes of these products. Bare Metal 1 VMware 1 Disk or VSS1/VSS2 Tape DVD Here are recommendations for various size attributes for ClearPath Bronze for the minimum allowable configuration and one which comfortably supports larger configurations. # of Intel Logical Minimum 2 (1 CPM) (1 CPM) Unisys Corporation Page 2 June 2016

3 ClearPath Silver System Type: GE1000 ClearPath Silver is a production level environment qualified for use on a client provided Reference Architecture computer utilizing either Bare Metal or a hypervisor. ClearPath Silver is a general purpose offering for environments having higher capacity requirements than can be provided by the ClearPath Bronze. The following table defines the attributes of these products. Bare Metal 1 or 2 VMware 1 or 2 Disk or VSS1/VSS2 Tape DVD Here are recommendations for various size attributes for ClearPath Silver for the minimum allowable configuration and one which comfortably supports larger configurations. # of Intel Logical Minimum 2 (1 CPM) (2 CPM) ClearPath Financial Server System Type: FS1000 ClearPath Financial Server is a production level environment qualified for use on a client provided Reference Architecture computer utilizing either Bare Metal or a hypervisor. ClearPath Financial Server is available to the Financial Series market only. The following table defines the attributes of this product. Bare Metal 1 to 4 VMware 1 to 4 Disk or VSS1/VSS2 Tape DVD Here are recommendations for various size attributes for ClearPath Financial Server for the minimum allowable configuration and one which comfortably supports larger configurations. # of Intel Logical Minimum 2 (1 CPM) (4 CPM) Unisys Corporation Page 3 June 2016

4 Required Software The following software components are required to be installed in Windows prior to installation and use of ClearPath Software Series. Microsoft.Net Framework Included in Windows 8.1 and - Separately downloadable for Windows 7 SP1 from Microsoft Windows Management Framework 4.0 (or greater) - Included in Windows 8.1 and - Separately downloadable for Windows 7 SP1 from Hardware Compatibility List ClearPath Software Series products have been tested on various Unisys ES3000 and Dell PowerEdge servers. These product lines conform to the ClearPath Software Series Reference Architecture, along with the other system attributes described in this document. Other servers are likely to work as well, but have not been tested. For information regarding supported disks, tapes and HBAs may see the Storage section later in this document. Software Compatibility List The third party software components listed below have been used with ClearPath Software Series products and were found to work reliably, although Unisys does not support them. Other non-os software packages may work as well, but have not been tested. Software Component EMC PowerPath ( only) Elaborate Bytes Virtual CloneDrive Symantec Endpoint Protection Emulex OC Manager Primary Use Allows multiple paths to a Read-only CD/DVD capability in environment Anti-virus software Centralized management tool for Emulex HBAs ClearPath Software Series is designed to work with Intel CPUs which support the x64 instruction set. Due to the way in which time is maintained in the, the processor(s) should support an Invariant Time Stamp Counter, which means they should be based on the Intel Nehalem microarchitecture and beyond. Nehalem processors from Intel were released in vember older than this may likely have an erratic ability to keep the correct time in the. In addition, if the Disk Encryption feature is desired, only the Intel Ivy Bridge microarchitecture and beyond supports this. More specifically, these are Intel CPUs which support Intel Data Protection Technology with AES-NI and Secure Key. The utilizes virtual processors called, which efficiently translate the s instruction set into equivalent Intel instructions and then execute them. Each of these can consume an Intel Logical Processor when under load. Additionally, the s I/O Processor (IOP) utilizes execution threads in the Windows environment for I/O activity. In order to handle the processor workload (CPM and IOP) with optimal performance, and also leave sufficient Intel performance to handle normal Windows operations, it is desirable to have more Intel Logical available than the number of Unisys Corporation Page 4 June 2016

5 The following table represents the Unisys minimum recommendations for Intel Logical. Logical Processor count may include actual cores or threads (also called hyper-threads). The use of more Logical than recommended may be advised for heavier Windows workloads or larger I/O configurations Intel Cores Selecting an Intel Processor When selecting a hardware platform for deploying a ClearPath Software Series system, one of the key choices is the Intel processor that the system uses. As described above, there are certain minimum requirements for the Intel processor used. The three key components of an Intel processor are its cores, its frequency (clock rate), and its cache size. Typically, the faster the Intel processor, the fewer cores there are, and the more expensive it will be. The choice should be based on the balance of your performance needs and your desired system configuration. Cache size can be a factor in the processor decision but, generally speaking, recent Intel processors have had sufficient cache for the CPM process to operate efficiently. When selecting a processor, consider the following: 1. The number of cores/logical needed for the environment (described in this document). 2. Whether or not the environment will be virtualized or partitioned. 3. The criticality of performance. When looking at performance, there is more to consider than a processor s frequency (clock-rate), specifically: 1. Base Frequency: The minimum clock rate if the BIOS settings are set as recommended in this document. 2. Maximum Frequency / Turbo Mode: Enabling Turbo typically provides the best performance, depending on other things happening in the system. 3. Generation of the Intel Processor: An older generation Intel processor will perform slower, sometimes significantly slower, than a newer processor having the same clock rate. It is often difficult to compare processors of different generations. Industry benchmarks provide a rough estimate of performance differences. However, no one benchmark reflects the performance difference seen for all workloads. The SPEC CINT2006 Base (Baseline) SPECint_base2006 benchmark most closely matches the typical workload. Visit the website for more information. The larger the Base/Baseline result the faster the processor. te that because this benchmark allows the processor to go into Turbo mode, it may be overstating the actual performance. However, it can be used as a very rough guide for comparison purposes. Processor Performance Settings While the above information regarding processors is useful, it does not tell the whole story with regards to achieving optimal performance. Given a particular processor, performance is best achieved by setting the system BIOS to optimal settings. The recommended BIOS settings for optimal performance are outlined in the following table. BIOS Setting Description CPU Power Management Frequency C1E Monitor/Mwait C-States Turbo Boost Logical Processor (threading) Optimal Performance Value Maximum Performance Maximum Performance Disabled Disabled Disabled Enabled Disabled 2016 Unisys Corporation Page 5 June 2016

6 It is recommended that you disable Logical Processor threading (hyper-threading) to reduce its overall impact on performance. While enabling threading makes more Logical available, each thread shares physical execution resources with another thread, causing the performance of each Logical Processor to be somewhat reduced. Enabling Logical Processor threading might be appropriate if individual CPM performance is not critical and more (or overall larger system capacity) are desirable. It is important to note that while these settings may produce the better performance, they are not necessarily recommended for situations where power consumption, heat dissipation, and other environmental factors are important. Many of these settings are best deployed in a datacenter, rather than a desktop. te that this list may not be exhaustive. Other settings may impact system performance as well. Firmware (the Windows software component of ClearPath Software Series) utilizes standard Windows memory management routines to acquire a contiguous block of memory for use by the. Depending upon the physical memory available in the system, the Firmware will allow the user to set a desired memory size ranging from a minimum of a maximum of. te that memory is generally described in words where one word is actually 8 bytes of physical memory. For example, 1GW of memory is equivalent to 8GB of physical memory. The minimum memory size for a ClearPath Software Series hosting environment is 2GB, whether it s a Bare Metal platform, an s-par partition, or a Virtual Machine. In addition to the memory needed for the environment, the system also needs memory for Windows and other platform functionality. A good rule of thumb is that Windows should have a minimum of about 2GB of memory for itself. Having said that, ClearPath Software Series products can function with less Windows memory where less memory is configured, and require more Windows memory where more memory is configured. In addition, the memory requirements of any other Windows-based applications running in the underlying Windows environment must be considered as well. The following table provides specific guidelines of how much physical memory the hosting environment requires for various memory sizes. 64MW 128MW 192MW 256MW 512MW 1GW 2GW 3GW Required (minimum) 2GB 2GB 3GB 4GB 8GB 16GB 24GB 32GB 40GB Some additional points should also be noted. Depending upon how much memory is available in the system at the time the Firmware attempts to acquire the memory, it will potentially reduce the memory size down to less than what is desired. Also, the longer Windows has been running prior to starting the Firmware memory service, the more likely that Windows memory has become fragmented, thus making it more difficult to obtain the desired contiguous memory. Additional memory beyond what s recommended may also help with performance. For example, if logical disks are in use, cache for these will be allocated from host system memory, not memory. If large numbers of IO devices are configured or if a significant amount of encryption is being performed, additional memory may also be beneficial. Storage ClearPath Software Series needs storage for several purposes. First, and most obvious, is the need to have storage for the underlying Windows environment. This includes the, application software, Firmware, and potential space for diagnostics if they need to be collected. In addition to that, there needs to be storage available for disks, which can take the form of either s (standard Windows files in the Windows file system) or VSS Disks (a unique file system native to but foreign to Windows). s can reside on any fixed media (non-removable) drive which has been formatted with the Windows NTFS file system. The drive can be either internal or external to the server chassis. Multiple drives in a RAID array are also 2016 Unisys Corporation Page 6 June 2016

7 permitted. The path to the cannot be encrypted or compressed using the standard Windows file system attributes. Encryption which happens outside of the OS, such as Bitlocker, is permitted. VSS Disks must reside externally, outboard of the server chassis using Fibre Channel, on either a Storage Area Network (SAN) or Direct Attach connection. Currently, only Emulex Fibre Channel host bus adapters have been qualified to communicate with VSS Disks. The Firmware, pre-installed Halt/Load (H/L) Unit, and Diagnostics reside on Windows storage volumes. About 30GB of disk space should be made available for Firmware and the preinstalled H/L, plus 34GB for each diagnostic dump you expect to save on the system. Then one must determine the space requirements for data packs. If internal storage is used for this purpose, what remains after accounting for Firmware, H/L Pack and Diagnostics can be used for additional Windows storage and/or s. If externally connected SAN disks are used, the remaining capacity can be used for additional Windows storage, s, or VSS Disks. A summary of the disks, tapes, HBAs and other storage products that Unisys has tested may be found in the ClearPath Software Series Peripheral Support Matrix located on the ClearPath Software Series page of the Unisys support website. ClearPath Software Series can be run in one of the following host environments: Over Bare Metal (Windows is running directly on the hardware) As a Virtual Machine running on a non-unisys Hypervisor In a Unisys ClearPath Forward fabric (over s-par) Refer to the Product Specific Information section for additional details on supported host environments. Bare Metal The Bare Metal server used to run a ClearPath Software Series product must conform to the Reference Architecture (RA) as detailed in the previous sections. Choosing a platform and associated peripherals listed in the Hardware Compatibility List is helpful to ensure conformance to the RA, although it is not required. The list of storage products which may be used as s when running on Bare Metal is determined by Microsoft s Hardware Compatibility List. Hypervisors Running ClearPath Software Series on a hypervisor is allowed for certain product models. When using a hypervisor, the sections of this document which reference memory, processor, etc. should be used to define the configuration of the Virtual Machine rather than the host platform. Regarding hardware compatibility, please refer to the Hardware Compatibility List of the vendor providing your Hypervisor rather than the HCL in this document. Unisys has done some basic testing of the following hypervisors with the ClearPath Software Series and found no issues. Others may work as well, but Unisys has not tested them. VMware ESXi 5.5 VMware ESXi 6.0 The following special considerations should be observed when using a hypervisor. tape or optical devices are supported on hypervisor based systems. Only s are supported. VSS is not supported on hypervisor-based systems. Changes to critical settings (virtual cores, memory, etc.) can be made much more dynamically with Virtual Machines. Many of these attributes are only checked by the Firmware during installation. Changing them after installation can lead to configuration issues which are not subsequently checked by the Firmware. Live Migration, which is the ability of a hypervisor to move a running VM from one host to another, while possible, might encounter performance issues for large configurations Unisys Corporation Page 7 June 2016

8 s-par Running ClearPath Software Series on Unisys Secure Partitioning (s-par) is allowed for certain product models which require a Unisys ClearPath Forward fabric. When using s-par, the sections of this document which reference memory, processor, etc. should be used to define the configuration of the logical partition rather than the host platform. Regarding platform compatibility, please ask your Unisys sales partner about the Unisys ClearPath Forward fabric product offerings. The following special considerations should be observed when using s-par. optical devices are supported on s-par based systems. Both s and VSS are supported. The minimum required Forward fabric environment for ClearPath Software Series is Fabric 3.0. Trademark and Copyright Information Unisys and other Unisys product and service names mentioned herein, as well as their respective logos, are trademarks or registered trademarks of Unisys Corporation. All other trademarks referenced herein are the property of their respective owners Unisys Corporation Page 8 June 2016

RUNNING vtvax FOR WINDOWS

RUNNING vtvax FOR WINDOWS RUNNING vtvax FOR WINDOWS IN A AVT / Vere Technologies TECHNICAL NOTE AVT/Vere Technical Note: Running vtvax for Windows in a Virtual Machine Environment Document Revision 1.1 (September, 2015) 2015 Vere

More information

Enabling Technologies for Distributed and Cloud Computing

Enabling Technologies for Distributed and Cloud Computing Enabling Technologies for Distributed and Cloud Computing Dr. Sanjay P. Ahuja, Ph.D. 2010-14 FIS Distinguished Professor of Computer Science School of Computing, UNF Multi-core CPUs and Multithreading

More information

Merge Healthcare Virtualization

Merge Healthcare Virtualization Merge Healthcare Virtualization CUSTOMER Merge Healthcare 900 Walnut Ridge Drive Hartland, WI 53029 USA 2014 Merge Healthcare. The information contained herein is confidential and is the sole property

More information

DIABLO TECHNOLOGIES MEMORY CHANNEL STORAGE AND VMWARE VIRTUAL SAN : VDI ACCELERATION

DIABLO TECHNOLOGIES MEMORY CHANNEL STORAGE AND VMWARE VIRTUAL SAN : VDI ACCELERATION DIABLO TECHNOLOGIES MEMORY CHANNEL STORAGE AND VMWARE VIRTUAL SAN : VDI ACCELERATION A DIABLO WHITE PAPER AUGUST 2014 Ricky Trigalo Director of Business Development Virtualization, Diablo Technologies

More information

RED HAT ENTERPRISE VIRTUALIZATION FOR SERVERS: COMPETITIVE FEATURES

RED HAT ENTERPRISE VIRTUALIZATION FOR SERVERS: COMPETITIVE FEATURES RED HAT ENTERPRISE VIRTUALIZATION FOR SERVERS: COMPETITIVE FEATURES RED HAT ENTERPRISE VIRTUALIZATION FOR SERVERS Server virtualization offers tremendous benefits for enterprise IT organizations server

More information

DELL. Dell Microsoft Windows Server 2008 Hyper-V TM Reference Architecture VIRTUALIZATION SOLUTIONS ENGINEERING

DELL. Dell Microsoft Windows Server 2008 Hyper-V TM Reference Architecture VIRTUALIZATION SOLUTIONS ENGINEERING DELL Dell Microsoft Windows Server 2008 Hyper-V TM Reference Architecture VIRTUALIZATION SOLUTIONS ENGINEERING September 2008 1 THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL

More information

Oracle Database Scalability in VMware ESX VMware ESX 3.5

Oracle Database Scalability in VMware ESX VMware ESX 3.5 Performance Study Oracle Database Scalability in VMware ESX VMware ESX 3.5 Database applications running on individual physical servers represent a large consolidation opportunity. However enterprises

More information

Host Power Management in VMware vsphere 5

Host Power Management in VMware vsphere 5 in VMware vsphere 5 Performance Study TECHNICAL WHITE PAPER Table of Contents Introduction.... 3 Power Management BIOS Settings.... 3 Host Power Management in ESXi 5.... 4 HPM Power Policy Options in ESXi

More information

Performance Characteristics of VMFS and RDM VMware ESX Server 3.0.1

Performance Characteristics of VMFS and RDM VMware ESX Server 3.0.1 Performance Study Performance Characteristics of and RDM VMware ESX Server 3.0.1 VMware ESX Server offers three choices for managing disk access in a virtual machine VMware Virtual Machine File System

More information

Enabling Technologies for Distributed Computing

Enabling Technologies for Distributed Computing Enabling Technologies for Distributed Computing Dr. Sanjay P. Ahuja, Ph.D. Fidelity National Financial Distinguished Professor of CIS School of Computing, UNF Multi-core CPUs and Multithreading Technologies

More information

Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and Dell PowerEdge M1000e Blade Enclosure

Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and Dell PowerEdge M1000e Blade Enclosure White Paper Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and Dell PowerEdge M1000e Blade Enclosure White Paper March 2014 2014 Cisco and/or its affiliates. All rights reserved. This

More information

Hyper-V R2: What's New?

Hyper-V R2: What's New? ASPE IT Training Hyper-V R2: What's New? A WHITE PAPER PREPARED FOR ASPE BY TOM CARPENTER www.aspe-it.com toll-free: 877-800-5221 Hyper-V R2: What s New? Executive Summary This white paper provides an

More information

Dell Virtualization Solution for Microsoft SQL Server 2012 using PowerEdge R820

Dell Virtualization Solution for Microsoft SQL Server 2012 using PowerEdge R820 Dell Virtualization Solution for Microsoft SQL Server 2012 using PowerEdge R820 This white paper discusses the SQL server workload consolidation capabilities of Dell PowerEdge R820 using Virtualization.

More information

Host Power Management in VMware vsphere 5.5

Host Power Management in VMware vsphere 5.5 in VMware vsphere 5.5 Performance Study TECHNICAL WHITE PAPER Table of Contents Introduction...3 Power Management BIOS Settings...3 Host Power Management in ESXi 5.5... 5 Relationship between HPM and DPM...

More information

Analysis of VDI Storage Performance During Bootstorm

Analysis of VDI Storage Performance During Bootstorm Analysis of VDI Storage Performance During Bootstorm Introduction Virtual desktops are gaining popularity as a more cost effective and more easily serviceable solution. The most resource-dependent process

More information

Running vtserver in a Virtual Machine Environment. Technical Note. 2015 by AVTware

Running vtserver in a Virtual Machine Environment. Technical Note. 2015 by AVTware Running vtserver in a Virtual Machine Environment Technical Note 2015 by AVTware Table of Contents 1. Scope... 3 1.1. Introduction... 3 2. General Virtual Machine Considerations... 4 2.1. The Virtualization

More information

SAN Conceptual and Design Basics

SAN Conceptual and Design Basics TECHNICAL NOTE VMware Infrastructure 3 SAN Conceptual and Design Basics VMware ESX Server can be used in conjunction with a SAN (storage area network), a specialized high speed network that connects computer

More information

ACANO SOLUTION VIRTUALIZED DEPLOYMENTS. White Paper. Simon Evans, Acano Chief Scientist

ACANO SOLUTION VIRTUALIZED DEPLOYMENTS. White Paper. Simon Evans, Acano Chief Scientist ACANO SOLUTION VIRTUALIZED DEPLOYMENTS White Paper Simon Evans, Acano Chief Scientist Updated April 2015 CONTENTS Introduction... 3 Host Requirements... 5 Sizing a VM... 6 Call Bridge VM... 7 Acano Edge

More information

Monitoring Databases on VMware

Monitoring Databases on VMware Monitoring Databases on VMware Ensure Optimum Performance with the Correct Metrics By Dean Richards, Manager, Sales Engineering Confio Software 4772 Walnut Street, Suite 100 Boulder, CO 80301 www.confio.com

More information

How System Settings Impact PCIe SSD Performance

How System Settings Impact PCIe SSD Performance How System Settings Impact PCIe SSD Performance Suzanne Ferreira R&D Engineer Micron Technology, Inc. July, 2012 As solid state drives (SSDs) continue to gain ground in the enterprise server and storage

More information

Windows Server 2008 R2 Hyper V. Public FAQ

Windows Server 2008 R2 Hyper V. Public FAQ Windows Server 2008 R2 Hyper V Public FAQ Contents New Functionality in Windows Server 2008 R2 Hyper V...3 Windows Server 2008 R2 Hyper V Questions...4 Clustering and Live Migration...5 Supported Guests...6

More information

How to Install the VMware ESXi Hypervisor on Physical Hardware

How to Install the VMware ESXi Hypervisor on Physical Hardware How to Install the VMware ESXi Hypervisor on Physical Hardware I am not responsible for your actions or their outcomes, in any way, while reading and/or implementing this tutorial. I will not provide support

More information

HP SN1000E 16 Gb Fibre Channel HBA Evaluation

HP SN1000E 16 Gb Fibre Channel HBA Evaluation HP SN1000E 16 Gb Fibre Channel HBA Evaluation Evaluation report prepared under contract with Emulex Executive Summary The computing industry is experiencing an increasing demand for storage performance

More information

MS Exchange Server Acceleration

MS Exchange Server Acceleration White Paper MS Exchange Server Acceleration Using virtualization to dramatically maximize user experience for Microsoft Exchange Server Allon Cohen, PhD Scott Harlin OCZ Storage Solutions, Inc. A Toshiba

More information

Optimizing LTO Backup Performance

Optimizing LTO Backup Performance Optimizing LTO Backup Performance July 19, 2011 Written by: Ash McCarty Contributors: Cedrick Burton Bob Dawson Vang Nguyen Richard Snook Table of Contents 1.0 Introduction... 3 2.0 Host System Configuration...

More information

IOS110. Virtualization 5/27/2014 1

IOS110. Virtualization 5/27/2014 1 IOS110 Virtualization 5/27/2014 1 Agenda What is Virtualization? Types of Virtualization. Advantages and Disadvantages. Virtualization software Hyper V What is Virtualization? Virtualization Refers to

More information

8Gb Fibre Channel Adapter of Choice in Microsoft Hyper-V Environments

8Gb Fibre Channel Adapter of Choice in Microsoft Hyper-V Environments 8Gb Fibre Channel Adapter of Choice in Microsoft Hyper-V Environments QLogic 8Gb Adapter Outperforms Emulex QLogic Offers Best Performance and Scalability in Hyper-V Environments Key Findings The QLogic

More information

Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and IBM FlexSystem Enterprise Chassis

Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and IBM FlexSystem Enterprise Chassis White Paper Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and IBM FlexSystem Enterprise Chassis White Paper March 2014 2014 Cisco and/or its affiliates. All rights reserved. This document

More information

IOmark- VDI. Nimbus Data Gemini Test Report: VDI- 130906- a Test Report Date: 6, September 2013. www.iomark.org

IOmark- VDI. Nimbus Data Gemini Test Report: VDI- 130906- a Test Report Date: 6, September 2013. www.iomark.org IOmark- VDI Nimbus Data Gemini Test Report: VDI- 130906- a Test Copyright 2010-2013 Evaluator Group, Inc. All rights reserved. IOmark- VDI, IOmark- VDI, VDI- IOmark, and IOmark are trademarks of Evaluator

More information

Vocera Voice 4.3 and 4.4 Server Sizing Matrix

Vocera Voice 4.3 and 4.4 Server Sizing Matrix Vocera Voice 4.3 and 4.4 Server Sizing Matrix Vocera Server Recommended Configuration Guidelines Maximum Simultaneous Users 450 5,000 Sites Single Site or Multiple Sites Requires Multiple Sites Entities

More information

Technical Paper. Moving SAS Applications from a Physical to a Virtual VMware Environment

Technical Paper. Moving SAS Applications from a Physical to a Virtual VMware Environment Technical Paper Moving SAS Applications from a Physical to a Virtual VMware Environment Release Information Content Version: April 2015. Trademarks and Patents SAS Institute Inc., SAS Campus Drive, Cary,

More information

The HBAs tested in this report are the Brocade 825 and the Emulex LPe12002 and LPe12000.

The HBAs tested in this report are the Brocade 825 and the Emulex LPe12002 and LPe12000. Emulex HBA Product Evaluation Evaluation report prepared under contract with Emulex Corporation Introduction Emulex Corporation commissioned Demartek to evaluate its 8 Gbps Fibre Channel host bus adapters

More information

FOR SERVERS 2.2: FEATURE matrix

FOR SERVERS 2.2: FEATURE matrix RED hat ENTERPRISE VIRTUALIZATION FOR SERVERS 2.2: FEATURE matrix Red hat enterprise virtualization for servers Server virtualization offers tremendous benefits for enterprise IT organizations server consolidation,

More information

EMC Unified Storage for Microsoft SQL Server 2008

EMC Unified Storage for Microsoft SQL Server 2008 EMC Unified Storage for Microsoft SQL Server 2008 Enabled by EMC CLARiiON and EMC FAST Cache Reference Copyright 2010 EMC Corporation. All rights reserved. Published October, 2010 EMC believes the information

More information

Virtual SAN Design and Deployment Guide

Virtual SAN Design and Deployment Guide Virtual SAN Design and Deployment Guide TECHNICAL MARKETING DOCUMENTATION VERSION 1.3 - November 2014 Copyright 2014 DataCore Software All Rights Reserved Table of Contents INTRODUCTION... 3 1.1 DataCore

More information

Summary. Key results at a glance:

Summary. Key results at a glance: An evaluation of blade server power efficiency for the, Dell PowerEdge M600, and IBM BladeCenter HS21 using the SPECjbb2005 Benchmark The HP Difference The ProLiant BL260c G5 is a new class of server blade

More information

SQL Server Virtualization

SQL Server Virtualization The Essential Guide to SQL Server Virtualization S p o n s o r e d b y Virtualization in the Enterprise Today most organizations understand the importance of implementing virtualization. Virtualization

More information

VMware Virtual SAN Backup Using VMware vsphere Data Protection Advanced SEPTEMBER 2014

VMware Virtual SAN Backup Using VMware vsphere Data Protection Advanced SEPTEMBER 2014 VMware SAN Backup Using VMware vsphere Data Protection Advanced SEPTEMBER 2014 VMware SAN Backup Using VMware vsphere Table of Contents Introduction.... 3 vsphere Architectural Overview... 4 SAN Backup

More information

Vendor and Hardware Platform: Fujitsu BX924 S2 Virtualization Platform: VMware ESX 4.0 Update 2 (build 261974)

Vendor and Hardware Platform: Fujitsu BX924 S2 Virtualization Platform: VMware ESX 4.0 Update 2 (build 261974) Vendor and Hardware Platform: Fujitsu BX924 S2 Virtualization Platform: VMware ESX 4.0 Update 2 (build 261974) Performance Section Performance Tested By: Fujitsu Test Date: 10-05-2010 Configuration Section

More information

EMC Integrated Infrastructure for VMware

EMC Integrated Infrastructure for VMware EMC Integrated Infrastructure for VMware Enabled by EMC Celerra NS-120 Reference Architecture EMC Global Solutions Centers EMC Corporation Corporate Headquarters Hopkinton MA 01748-9103 1.508.435.1000

More information

Virtualization and the U2 Databases

Virtualization and the U2 Databases Virtualization and the U2 Databases Brian Kupzyk Senior Technical Support Engineer for Rocket U2 Nik Kesic Lead Technical Support for Rocket U2 Opening Procedure Orange arrow allows you to manipulate the

More information

High Performance Tier Implementation Guideline

High Performance Tier Implementation Guideline High Performance Tier Implementation Guideline A Dell Technical White Paper PowerVault MD32 and MD32i Storage Arrays THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS

More information

Video Surveillance Storage and Verint Nextiva NetApp Video Surveillance Storage Solution

Video Surveillance Storage and Verint Nextiva NetApp Video Surveillance Storage Solution Technical Report Video Surveillance Storage and Verint Nextiva NetApp Video Surveillance Storage Solution Joel W. King, NetApp September 2012 TR-4110 TABLE OF CONTENTS 1 Executive Summary... 3 1.1 Overview...

More information

Accelerating Application Performance on Virtual Machines

Accelerating Application Performance on Virtual Machines Accelerating Application Performance on Virtual Machines...with flash-based caching in the server Published: August 2011 FlashSoft Corporation 155-A W. Moffett Park Dr Sunnyvale, CA 94089 info@flashsoft.com

More information

NetScaler VPX FAQ. Table of Contents

NetScaler VPX FAQ. Table of Contents NetScaler VPX FAQ Table of Contents Feature and Functionality Frequently Asked Questions... 2 Pricing and Packaging Frequently Asked Questions... 4 NetScaler VPX Express Frequently Asked Questions... 5

More information

Virtualizing Microsoft SQL Server 2008 on the Hitachi Adaptable Modular Storage 2000 Family Using Microsoft Hyper-V

Virtualizing Microsoft SQL Server 2008 on the Hitachi Adaptable Modular Storage 2000 Family Using Microsoft Hyper-V Virtualizing Microsoft SQL Server 2008 on the Hitachi Adaptable Modular Storage 2000 Family Using Microsoft Hyper-V Implementation Guide By Eduardo Freitas and Ryan Sokolowski February 2010 Summary Deploying

More information

v7.1 Technical Specification

v7.1 Technical Specification v7.1 Technical Specification Copyright 2011 Sage Technologies Limited, publisher of this work. All rights reserved. No part of this documentation may be copied, photocopied, reproduced, translated, microfilmed,

More information

ClearPath MCP Developer Studio

ClearPath MCP Developer Studio ClearPath MCP Developer Studio ClearPath MCP Releases 16.0 and 17.0 ClearPath Software Series The ClearPath Software Series is a new innovative collection of software-only solutions without a traditional

More information

Implementing Red Hat Enterprise Linux 6 on HP ProLiant servers

Implementing Red Hat Enterprise Linux 6 on HP ProLiant servers Technical white paper Implementing Red Hat Enterprise Linux 6 on HP ProLiant servers Table of contents Abstract... 2 Introduction to Red Hat Enterprise Linux 6... 2 New features... 2 Recommended ProLiant

More information

Hypervisor Software and Virtual Machines. Professor Howard Burpee SMCC Computer Technology Dept.

Hypervisor Software and Virtual Machines. Professor Howard Burpee SMCC Computer Technology Dept. Hypervisor Software and Virtual Machines Learning Objectives Understand the common features of today s desktop virtualization products Select and implement a desktop virtualization option on a Linux, Mac,

More information

Virtualization Technologies and Blackboard: The Future of Blackboard Software on Multi-Core Technologies

Virtualization Technologies and Blackboard: The Future of Blackboard Software on Multi-Core Technologies Virtualization Technologies and Blackboard: The Future of Blackboard Software on Multi-Core Technologies Kurt Klemperer, Principal System Performance Engineer kklemperer@blackboard.com Agenda Session Length:

More information

EMC Integrated Infrastructure for VMware

EMC Integrated Infrastructure for VMware EMC Integrated Infrastructure for VMware Enabled by Celerra Reference Architecture EMC Global Solutions Centers EMC Corporation Corporate Headquarters Hopkinton MA 01748-9103 1.508.435.1000 www.emc.com

More information

Maximizing VMware ESX Performance Through Defragmentation of Guest Systems. Presented by

Maximizing VMware ESX Performance Through Defragmentation of Guest Systems. Presented by Maximizing VMware ESX Performance Through Defragmentation of Guest Systems Presented by July, 2010 Table of Contents EXECUTIVE OVERVIEW 3 TEST EQUIPMENT AND METHODS 4 TESTING OVERVIEW 5 Fragmentation in

More information

Achieve Automated, End-to-End Firmware Management with Cisco UCS Manager

Achieve Automated, End-to-End Firmware Management with Cisco UCS Manager Achieve Automated, End-to-End Firmware Management with Cisco UCS Manager What You Will Learn This document describes the operational benefits and advantages of firmware provisioning with Cisco UCS Manager

More information

MICROSOFT HYPER-V SCALABILITY WITH EMC SYMMETRIX VMAX

MICROSOFT HYPER-V SCALABILITY WITH EMC SYMMETRIX VMAX White Paper MICROSOFT HYPER-V SCALABILITY WITH EMC SYMMETRIX VMAX Abstract This white paper highlights EMC s Hyper-V scalability test in which one of the largest Hyper-V environments in the world was created.

More information

Dell PowerEdge Blades Outperform Cisco UCS in East-West Network Performance

Dell PowerEdge Blades Outperform Cisco UCS in East-West Network Performance Dell PowerEdge Blades Outperform Cisco UCS in East-West Network Performance This white paper compares the performance of blade-to-blade network traffic between two enterprise blade solutions: the Dell

More information

Selecting NetVanta UC Server Hypervisor and Server Platforms

Selecting NetVanta UC Server Hypervisor and Server Platforms NetVanta Unified Communications Technical Note Selecting NetVanta UC Server Hypervisor and Server Platforms Introduction This technical note specifies the minimum computer hardware requirements for NetVanta

More information

Balancing CPU, Storage

Balancing CPU, Storage TechTarget Data Center Media E-Guide Server Virtualization: Balancing CPU, Storage and Networking Demands Virtualization initiatives often become a balancing act for data center administrators, who are

More information

Created on May 20, 2015

Created on May 20, 2015 Symantec System Recovery 2013, Symantec System Recovery 2013 Linux Edition, Symantec System Recovery 2013 Management Solution, and Symantec System Recovery 2013 Monitor Software Compatibility List Created

More information

Design Considerations for Increasing VDI Performance and Scalability with Cisco Unified Computing System

Design Considerations for Increasing VDI Performance and Scalability with Cisco Unified Computing System White Paper Design Considerations for Increasing VDI Performance and Scalability with Cisco Unified Computing System White Paper April 2013 2013 Cisco and/or its affiliates. All rights reserved. This document

More information

ThinkServer RD350 and RD450 Operating System Installation Guide

ThinkServer RD350 and RD450 Operating System Installation Guide ThinkServer RD350 and RD450 Operating System Installation Guide Note: Before using this information and the product it supports, be sure to read and understand the Read Me First and Safety, Warranty, and

More information

Symantec NetBackup 5220

Symantec NetBackup 5220 A single-vendor enterprise backup appliance that installs in minutes Data Sheet: Data Protection Overview is a single-vendor enterprise backup appliance that installs in minutes, with expandable storage

More information

DELL TM PowerEdge TM T610 500 Mailbox Resiliency Exchange 2010 Storage Solution

DELL TM PowerEdge TM T610 500 Mailbox Resiliency Exchange 2010 Storage Solution DELL TM PowerEdge TM T610 500 Mailbox Resiliency Exchange 2010 Storage Solution Tested with: ESRP Storage Version 3.0 Tested Date: Content DELL TM PowerEdge TM T610... 1 500 Mailbox Resiliency

More information

Accelerating Microsoft Exchange Servers with I/O Caching

Accelerating Microsoft Exchange Servers with I/O Caching Accelerating Microsoft Exchange Servers with I/O Caching QLogic FabricCache Caching Technology Designed for High-Performance Microsoft Exchange Servers Key Findings The QLogic FabricCache 10000 Series

More information

IOmark-VM. DotHill AssuredSAN Pro 5000. Test Report: VM- 130816-a Test Report Date: 16, August 2013. www.iomark.org

IOmark-VM. DotHill AssuredSAN Pro 5000. Test Report: VM- 130816-a Test Report Date: 16, August 2013. www.iomark.org IOmark-VM DotHill AssuredSAN Pro 5000 Test Report: VM- 130816-a Test Report Date: 16, August 2013 Copyright 2010-2013 Evaluator Group, Inc. All rights reserved. IOmark-VM, IOmark-VDI, VDI-IOmark, and IOmark

More information

Comparing Free Virtualization Products

Comparing Free Virtualization Products A S P E I T Tr a i n i n g Comparing Free Virtualization Products A WHITE PAPER PREPARED FOR ASPE BY TONY UNGRUHE www.aspe-it.com toll-free: 877-800-5221 Comparing Free Virtualization Products In this

More information

Virtualization. Dr. Yingwu Zhu

Virtualization. Dr. Yingwu Zhu Virtualization Dr. Yingwu Zhu What is virtualization? Virtualization allows one computer to do the job of multiple computers. Virtual environments let one computer host multiple operating systems at the

More information

Dell High Availability Solutions Guide for Microsoft Hyper-V

Dell High Availability Solutions Guide for Microsoft Hyper-V Dell High Availability Solutions Guide for Microsoft Hyper-V www.dell.com support.dell.com Notes and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

Cisco WebEx Meetings Server System Requirements

Cisco WebEx Meetings Server System Requirements First Published: October 21, 2012 Last Modified: October 21, 2012 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 8 526-00 800 553-NETS

More information

Configuration Maximums

Configuration Maximums Topic Configuration s VMware vsphere 5.1 When you select and configure your virtual and physical equipment, you must stay at or below the maximums supported by vsphere 5.1. The limits presented in the

More information

Integration and Automation with Lenovo XClarity Administrator

Integration and Automation with Lenovo XClarity Administrator Integration and Automation with Lenovo XClarity Administrator Extend Management Processes to Existing Ecosystems Lenovo Enterprise Business Group April 2015 2015 Lenovo. All rights reserved. Introduction

More information

MaxDeploy Ready. Hyper- Converged Virtualization Solution. With SanDisk Fusion iomemory products

MaxDeploy Ready. Hyper- Converged Virtualization Solution. With SanDisk Fusion iomemory products MaxDeploy Ready Hyper- Converged Virtualization Solution With SanDisk Fusion iomemory products MaxDeploy Ready products are configured and tested for support with Maxta software- defined storage and with

More information

Directions for VMware Ready Testing for Application Software

Directions for VMware Ready Testing for Application Software Directions for VMware Ready Testing for Application Software Introduction To be awarded the VMware ready logo for your product requires a modest amount of engineering work, assuming that the pre-requisites

More information

Why VDI s Time Is Finally Here

Why VDI s Time Is Finally Here Why VDI s Time Is Finally Here After years of hype and heady predictions, the time is finally right for midsize organizations to take advantage of the many benefits afforded by Virtual Desktop Infrastructure,

More information

System Requirements. Version 8.2 November 23, 2015. For the most recent version of this document, visit our documentation website.

System Requirements. Version 8.2 November 23, 2015. For the most recent version of this document, visit our documentation website. System Requirements Version 8.2 November 23, 2015 For the most recent version of this document, visit our documentation website. Table of Contents 1 System requirements 3 2 Scalable infrastructure example

More information

How To Connect Virtual Fibre Channel To A Virtual Box On A Hyperv Virtual Machine

How To Connect Virtual Fibre Channel To A Virtual Box On A Hyperv Virtual Machine Virtual Fibre Channel for Hyper-V Virtual Fibre Channel for Hyper-V, a new technology available in Microsoft Windows Server 2012, allows direct access to Fibre Channel (FC) shared storage by multiple guest

More information

VMware VMmark V1.1.1 Results

VMware VMmark V1.1.1 Results VMware VMmark V1.1.1 Results Vendor and Hardware Platform: Lenovo R525 G2 Virtualization Platform: VMware ESX 4.0(build 164009) Performance Section Performance Tested By: Lenovo Test Date: 06/05/2009 Configuration

More information

Reference Architecture for a Virtualized SharePoint 2010 Document Management Solution A Dell Technical White Paper

Reference Architecture for a Virtualized SharePoint 2010 Document Management Solution A Dell Technical White Paper Dell EqualLogic Best Practices Series Reference Architecture for a Virtualized SharePoint 2010 Document Management Solution A Dell Technical White Paper Storage Infrastructure and Solutions Engineering

More information

N-central 8.0 On-Premise Software and N-compass 3.1 Advanced Reporting Software

N-central 8.0 On-Premise Software and N-compass 3.1 Advanced Reporting Software System Requirements N-central 8.0 On-Premise Software and N-compass 3.1 Advanced Reporting Software The following describes the server requirements for N-central 8.0 and its optional advanced reporting

More information

White Paper. Recording Server Virtualization

White Paper. Recording Server Virtualization White Paper Recording Server Virtualization Prepared by: Mike Sherwood, Senior Solutions Engineer Milestone Systems 23 March 2011 Table of Contents Introduction... 3 Target audience and white paper purpose...

More information

KVM Virtualized I/O Performance

KVM Virtualized I/O Performance KVM Virtualized I/O Performance Achieving Unprecedented I/O Performance Using Virtio-Blk-Data-Plane Technology Preview in SUSE Linux Enterprise Server 11 Service Pack 3 (SP3) Khoa Huynh, IBM Linux Technology

More information

Bare Metal Recovery Quick Start Guide

Bare Metal Recovery Quick Start Guide Bare Metal Recovery Quick Start Guide Revisions Document Control Version 5.4.3 Status Changes Date Final Created. August 2014 Copyright 2003-2014 Intronis, Inc. All rights reserved. 1 Table of Contents

More information

VDI Without Compromise with SimpliVity OmniStack and Citrix XenDesktop

VDI Without Compromise with SimpliVity OmniStack and Citrix XenDesktop VDI Without Compromise with SimpliVity OmniStack and Citrix XenDesktop Page 1 of 11 Introduction Virtual Desktop Infrastructure (VDI) provides customers with a more consistent end-user experience and excellent

More information

EMC Virtual Infrastructure for SAP Enabled by EMC Symmetrix with Auto-provisioning Groups, Symmetrix Management Console, and VMware vcenter Converter

EMC Virtual Infrastructure for SAP Enabled by EMC Symmetrix with Auto-provisioning Groups, Symmetrix Management Console, and VMware vcenter Converter EMC Virtual Infrastructure for SAP Enabled by EMC Symmetrix with Auto-provisioning Groups, VMware vcenter Converter A Detailed Review EMC Information Infrastructure Solutions Abstract This white paper

More information

QuickSpecs. HP Integrity Virtual Machines (Integrity VM) Overview. Currently shipping versions:

QuickSpecs. HP Integrity Virtual Machines (Integrity VM) Overview. Currently shipping versions: Currently shipping versions: HP Integrity VM (HP-UX 11i v2 VM Host) v3.5 HP Integrity VM (HP-UX 11i v3 VM Host) v4.1 Integrity Virtual Machines (Integrity VM) is a soft partitioning and virtualization

More information

Virtual server management: Top tips on managing storage in virtual server environments

Virtual server management: Top tips on managing storage in virtual server environments Tutorial Virtual server management: Top tips on managing storage in virtual server environments Sponsored By: Top five tips for managing storage in a virtual server environment By Eric Siebert, Contributor

More information

UEFI on Dell BizClient Platforms

UEFI on Dell BizClient Platforms UEFI on Dell BizClient Platforms Authors: Anand Joshi Kurt Gillespie This document is for informational purposes only and may contain typographical errors and technical inaccuracies. The content is provided

More information

unisys ClearPath Enterprise Servers Virtual Machine for ClearPath MCP Installation Guide Virtual Machine for ClearPath MCP Version 10.

unisys ClearPath Enterprise Servers Virtual Machine for ClearPath MCP Installation Guide Virtual Machine for ClearPath MCP Version 10. unisys ClearPath Enterprise Servers Virtual Machine for ClearPath MCP Installation Guide Virtual Machine for ClearPath MCP Version 10.0, SP2 September 2011 3843 4072 001 NO WARRANTIES OF ANY NATURE ARE

More information

Optimized Storage Solution for Enterprise Scale Hyper-V Deployments

Optimized Storage Solution for Enterprise Scale Hyper-V Deployments Optimized Storage Solution for Enterprise Scale Hyper-V Deployments End-to-End Storage Solution Enabled by Sanbolic Melio FS and LaScala Software and EMC SAN Solutions Proof of Concept Published: March

More information

Distribution One Server Requirements

Distribution One Server Requirements Distribution One Server Requirements Introduction Welcome to the Hardware Configuration Guide. The goal of this guide is to provide a practical approach to sizing your Distribution One application and

More information

Enabling VMware Enhanced VMotion Compatibility on HP ProLiant servers

Enabling VMware Enhanced VMotion Compatibility on HP ProLiant servers Enabling VMware Enhanced VMotion Compatibility on HP ProLiant servers Technical white paper Table of contents Executive summary... 2 VMware VMotion overview... 2 VMotion CPU compatibility... 2 Enhanced

More information

Virtualization of the MS Exchange Server Environment

Virtualization of the MS Exchange Server Environment MS Exchange Server Acceleration Maximizing Users in a Virtualized Environment with Flash-Powered Consolidation Allon Cohen, PhD OCZ Technology Group Introduction Microsoft (MS) Exchange Server is one of

More information

System Requirements Table of contents

System Requirements Table of contents Table of contents 1 Introduction... 2 2 Knoa Agent... 2 2.1 System Requirements...2 2.2 Environment Requirements...4 3 Knoa Server Architecture...4 3.1 Knoa Server Components... 4 3.2 Server Hardware Setup...5

More information

Best Practices for Installing and Configuring the Hyper-V Role on the LSI CTS2600 Storage System for Windows 2008

Best Practices for Installing and Configuring the Hyper-V Role on the LSI CTS2600 Storage System for Windows 2008 Best Practices Best Practices for Installing and Configuring the Hyper-V Role on the LSI CTS2600 Storage System for Windows 2008 Installation and Configuration Guide 2010 LSI Corporation August 13, 2010

More information

Basics in Energy Information (& Communication) Systems Virtualization / Virtual Machines

Basics in Energy Information (& Communication) Systems Virtualization / Virtual Machines Basics in Energy Information (& Communication) Systems Virtualization / Virtual Machines Dr. Johann Pohany, Virtualization Virtualization deals with extending or replacing an existing interface so as to

More information

IOmark- VDI. HP HP ConvergedSystem 242- HC StoreVirtual Test Report: VDI- HC- 150427- b Test Report Date: 27, April 2015. www.iomark.

IOmark- VDI. HP HP ConvergedSystem 242- HC StoreVirtual Test Report: VDI- HC- 150427- b Test Report Date: 27, April 2015. www.iomark. IOmark- VDI HP HP ConvergedSystem 242- HC StoreVirtual Test Report: VDI- HC- 150427- b Test Copyright 2010-2014 Evaluator Group, Inc. All rights reserved. IOmark- VDI, IOmark- VM, VDI- IOmark, and IOmark

More information

Symantec Backup Exec.cloud

Symantec Backup Exec.cloud Automatic, continuous, and secure protection that backs up data to the cloud, or via a hybrid approach combining on-premise and cloud-based backup. Data Sheet: Symantec.cloud Only 21 percent of SMBs are

More information

Lab Validation Report

Lab Validation Report Lab Validation Report Microsoft SQL Server 2008 R2 and Hyper-V R2 SP1 Performance Analysis Virtualizing Tier-1 Application Workloads with Confidence By Brian Garrett June 2011 Lab Validation: Microsoft

More information

MIGRATING LEGACY PHYSICAL SERVERS TO HYPER-V VIRTUAL MACHINES ON DELL POWEREDGE M610 BLADE SERVERS FEATURING THE INTEL XEON PROCESSOR 5500 SERIES

MIGRATING LEGACY PHYSICAL SERVERS TO HYPER-V VIRTUAL MACHINES ON DELL POWEREDGE M610 BLADE SERVERS FEATURING THE INTEL XEON PROCESSOR 5500 SERIES MIGRATING LEGACY PHYSICAL SERVERS TO HYPER-V VIRTUAL MACHINES ON DELL POWEREDGE M610 BLADE SERVERS FEATURING THE INTEL XEON PROCESSOR 5500 SERIES Table of contents Table of contents... 2 Introduction...

More information

Remote PC Guide Series - Volume 2b

Remote PC Guide Series - Volume 2b Document Version: 2013-09-06 R720 This guide provides hardware model-specific guidance in server configuration, with BIOS and RAID configuration instructions for the Dell R720. This guide is part of a

More information