EN and EN : 2008 Integrated standards for telecommunications cabling installation

Size: px
Start display at page:

Download "EN 50174-1 and EN 50174-2: 2008 Integrated standards for telecommunications cabling installation"

Transcription

1 EN EN EN EN EN EN EN EN EN DESIGN INSPECTION TESTING PLANNING INSTALLATION National Standards National Regulations EN and EN : 2008 Integrated standards for telecommunications cabling installation

2 Mike Gilmore Mike Gilmore Managing Director e-ready Building Standards Activities Member JTC1 SC25 WG3: Generic Cabling Convenor JTC1 SC25 WG3 CITG: Cabling Implementation Task Group JTC1 SC25 WG3 IPTG: Industrial Premises (Cabling) Task Group Convenor TC215 WG1: IT Cabling Secretary TC215 WG2 Leader - Special Task Force 362 Energy Efficiency and Broadband Deployment Chairman TCT7: Telecommunications - Installation Requirements Chairman TCT7/-/1: Cabling infrastructure design, planning and commissioning TCT7/-/3: Cabling: Infrastructure standards - UK implementation panel FIA Technical and Standards Director Fibreoptic Industry Association Director Telecommunications Infrastructure Advisory Board Mobile: +44 (0) mike.gilmore@btinternet.com

3 Problems with EN /-2 Ed.1 EN :2000 EN :2000 EN :2003 PRODUCED BY CENELEC TC215 Information technology - Cabling installation - Part 1: Specification and quality assurance Information technology - Cabling installation - Part 2: Installation planning and practices inside buildings Information technology - Cabling installation - Part 3: Installation planning and practices outside buildings Some SHOULDS should be SHALLS and some SHALLS should be SHOULDS Segregation of circuits Confuses optical fibre and copper requirements Mismatch of terms Focus on specifics rather than requirements Too much tutorial

4 Linkage to EN series EN :2007, EN :2007, EN :2007, EN :2007

5 EN and EN EN X Ed.2 EN :2008 EN :2008 PRODUCED BY CENELEC TC215 Information technology - Cabling installation - Part 1: Installation Specification and quality assurance Information technology - Cabling installation - Part 2: Installation planning and practices inside buildings CLC approval November 2008

6 EN and EN EN :2008 EN :2008 PRODUCED BY CENELEC TC215 Information technology - Cabling installation - Part 1: Installation Specification and quality assurance EN :2000 EN :2008 Introduction Introduction Scope Scope 1 Conformance Normative references 2 Normative references Definitions and abbreviations 3 Terms, definitions and abbreviations Specification considerations Quality assurance 4 5 Requirements for specifying installations of information technology cabling Requirements for installers of information technology cabling Documentation Cabling administration Repair and maintenance Infrastructure complexity Compatibility between transmission systems (balanced and unbalanced) sharing the same cable sheath within information technology cabling Terminating cables on terminating blocks in floor distributors A B A B C D Minimum requirements for technical specifications and quality plans Polarity maintenance: connecting hardware for multiple optical fibres Terminating cables on terminating blocks in distributors Compatibility between transmission systems (balanced and unbalanced) sharing the same cable sheath within information technology cabling

7 EN and EN EN :2008 EN :2008 PRODUCED BY CENELEC TC215 Information technology - Cabling installation - Part 2: Installation planning and practices inside buildings EN :2000 EN :2008 Introduction Introduction Scope Scope 1 Conformance Normative references 2 Normative references Definitions and abbreviations 3 Terms, definitions and abbreviations General installation practices for metallic and optical fibre cabling Additional installation practices for metallic cabling Additional installation practices for optical fibre cabling Requirements for planning installations of information technology cabling Requirements for the installation of information technology cabling Segregation of metallic information technology cabling and mains power cabling Electricity distribution systems and lightning protection Office (commercial) premises Industrial premises Homes Data centres Coupling mechanisms and counter-measures A A B EMC and protection Application of responsibilities

8 EN and EN Infrastructure Complexity EN :2008 PRODUCED BY CENELEC TC215 Information technology - Cabling installation - Part 1: Installation Specification and quality assurance Installation Complexity Office Industrial Homes Multi-tenant residential premises Data centres E = No. of fixed cable elements (E) 2 to to 1000 > LEVEL The number of fixed cables multiplied by the number of cable elements per cable. It is the total for all cables (coaxial, balanced pair and optical fibre) Operational Complexity Office Industrial Homes Multi-tenant residential premises Data centres No. of administered ports (P) 2 to to to LEVEL > P = The number of user-accessible equipment interfaces including those on the connected equipment

9 EN and EN Segregation Classification SEGREGATION BETWEEN INFORMATION TECHNOLOGY AND MAINS POWER CABLING S/FTP CABLE CATEGORY Balanced Unscreened Screened Coaxial Segregation Classification 7 or BCT-B BCT-C d F/UTP 5 or 6 c 5 or 6 b Other or None a U/UTP Segregation Classification a shall be applied if: the applications to be supported are unrestricted; the type of cabling to be installed is unrestricted. Segregation Classification b and above may be applied if the applications are supported by the EN series of standards

10 EN and EN Separation Distance Overview SEGREGATION BETWEEN INFORMATION TECHNOLOGY AND MAINS POWER CABLING None CABLE MANAGEMENT SYSTEM Open metallic containment Perforated metallic containment Solid metallic containment Segregation Classification S = Basic separation distance (mm, min) d c b a Electrical circuit type Quantity of circuits Separation multiplier 20 amp 230 V AC 1- phase 3-phase cables = 3 off 1-phase cables > 20 A = multiples of 20 A 60 A 0,2 120 A 0,4 180 A 0,6 240 A 0,8 300 A A A A A A 6

11 EN and EN Zero Separation Get-Out SEGREGATION BETWEEN INFORMATION TECHNOLOGY AND MAINS POWER CABLING No segregation is required between information technology cabling and mains power cabling (other than that required by national or local regulation) provided that all the following conditions are met: the environmental classification for the information technology cabling complies with E 1 of EN ; the power conductors and form single phase circuits; provide a total current 32 amps (max); comprising a circuit are maintained in close proximity (e.g. within an overall sheath or twisted, taped or bundled together); the information technology cables meet the requirements of Segregation Classifications b, c or d ; or where the cabling is application(s)-specific and the application(s) supports a zero segregation relaxation. This allowance should be not applied in spaces allocated to distributors in accordance with EN standards or equivalent concentrations of transmission equipment

12 EN and EN Mains Power Cabling Standards SEGREGATION BETWEEN INFORMATION TECHNOLOGY AND MAINS POWER CABLING PROPOSALS WITHIN EUROPEAN HD S = Basic separation distance (mm, min) None CABLE MANAGEMENT SYSTEM Open metallic containment the total current in the LV cables does not exceed 600A Perforated metallic containment ASSUMPTIONS Solid metallic containment 0 balanced information telecommunication cables have electromagnetic immunity performance in accordance with EN series standards for Category 5 and above coaxial information technology cables have electromagnetic immunity performance in accordance with EN standard for Category BCT-C the applications supported by the cabling are designed to operate using the information technology cabling installed or to be installed

13 Conformance to EN /-2 PRODUCED BY CENELEC TC215 EN :2008: For a cabling installation to conform to this European Standard: the specification of the installation shall meet the requirements of clause 4; the installer shall meet the requirements of clause 5; the equipotential bonding (and earthing) system within the premises shall be in accordance with ; where a lightning protection system is required, it shall conform to the integrated lightning protection system according to EN ; other lightning protection systems, including the isolated lightning protection system according to EN are allowed provided that specific restrictions are applied both to the implementation of the information technology cabling and the requirements of as agreed between the planners of the lightning protection system and the information technology cabling; local regulations, including safety, shall be met. EN :2008: For a cabling installation to conform to this European Standard: the planning of the installation shall meet the requirements of clause 4; the installation practices shall meet the requirements of clause 5; the additional requirements of the applicable premises-specific clause shall be met; the equipotential bonding (and earthing) system within the premises shall be in accordance with ; where a lightning protection system is required, it shall conform to the integrated lightning protection system according to EN ; other lightning protection systems. cabling; local regulations, including safety, shall be met.

14 :2009 :2009 PRODUCED BY CENELEC TC215 Application of equipotential bonding and earthing in buildings with information technology equipment HD 384/60364 Equipment-specific PROTECTION/SAFETY FUNCTIONAL IMMUNITY PURPOSE OF EARTHING For a given protective earthing system provides requirements for additional bonds for equipotentiality Defines performance/characteristics of bonds

15 Star and Ring Earth Improvements :2009 PRODUCED BY CENELEC TC215 Application of equipotential bonding and earthing in buildings with information technology equipment

16 Mesh Earth Improvements :2009 PRODUCED BY CENELEC TC215 Application of equipotential bonding and earthing in buildings with information technology equipment

17 FIA Approved Installers Scheme

18 Related activities and actions FIA AID

19 Related activities and actions FIA AID Assistant

20 EN EN EN EN EN EN EN EN EN DESIGN INSPECTION TESTING PLANNING INSTALLATION The End National Standards National Regulations EN and EN : 2008 Integrated standards for telecommunications cabling installation

FIA FIA. Installation Standards - 2004. e-ready Building Next Generation IT infrastructures. ϕ The Cabling Partnership AGENDA

FIA FIA. Installation Standards - 2004. e-ready Building Next Generation IT infrastructures. ϕ The Cabling Partnership AGENDA Installation Standards - 2004 January 2004, Issue 1 Mike Gilmore Standards Activities Member: ISO/IEC JTC1 SC25 WG3: Generic Cabling ISO/IEC JTC1 SC25 Project Team: SOHO Convenor: ISO/IEC JTC1 SC25 WG3

More information

Cabling for 10GBASE-T and Beyond - A Tangled Web

Cabling for 10GBASE-T and Beyond - A Tangled Web Augmented Category 6 Category 6 A CLC TR 50173-99-1 TIA/EIA-TSB-155 TIA/EIA-568-B.2-10 ISO/IEC 11801 A1.1 Class E A Class F A ISO/IEC 11801 A1.2 Category 7 A ISO/IEC TR 24750 ISO/IEC 11801 Cabling for

More information

Power Separation Guidelines for SYSTIMAX Installations

Power Separation Guidelines for SYSTIMAX Installations SYSTIMAX Solutions Power Separation Guidelines for SYSTIMAX Installations Design and installation guidelines August 2011 www.commscope.com 1.0 General These guidelines are based on extensive testing and

More information

Testing Installed Cabling - we know not what we do! Mike Gilmore FIA Technical Director

Testing Installed Cabling - we know not what we do! Mike Gilmore FIA Technical Director Testing Installed Cabling - we know not what we do! Mike Gilmore FIA Technical irector Mike Gilmore tandards Activities Member: IO/IEC JTC1 C25 WG3: Generic Cabling IO/IEC JTC1 C25 Project Team: OHO Convenor:

More information

Screened cable and data cable segregation

Screened cable and data cable segregation December 2007 Screened cable and data cable segregation Can an armoured power cable be considered a screened cable and how does this relate to power and data cable segregation? The short answer is yes;

More information

Structured Cabling, Earthing & Equipotential Bonding

Structured Cabling, Earthing & Equipotential Bonding White Paper Information and Communication Technology Structured Cabling, Earthing & Equipotential Bonding English Rev. 1.0.1 / 2012-06-01 1 Abstract All Dallmeier network products (PoE cameras, recorders,

More information

Separation of power and information technology cabling

Separation of power and information technology cabling Technical bulletin Separation of power and information technology cabling Date: 08/2006 This technical bulletin provides you with information on specific technical subjects. It is based on the current

More information

Foreword. Page 2 EN 50174-2:2000

Foreword. Page 2 EN 50174-2:2000 Page 2 Foreword This European Standard has been prepared by Technical Committee CENELEC TC 215 "Electrotechnical aspects of telecommunication equipment" under the framework of the Mandates M/212 on Telecommunication

More information

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair Presentation; Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair 5 th April 2010 Paul Mathews MInstSMM, CCNA, MIEEE Global Channel Manager Media Types Physical Layer Cabling;

More information

Cabling Standards Update 2014

Cabling Standards Update 2014 Cabling Standards Update 2014 Dimitris Filippou Technical Director, Ltd. IEEE Member, BICSI Country Chair, ELOT Technical Committee TC93 Member, CENELEC TC215 Delegate of Greek National Committee, CENELEC

More information

SECTION 13: COMMUNICATIONS CONTENTS

SECTION 13: COMMUNICATIONS CONTENTS SECTION 13: COMMUNICATIONS CONTENTS 13.1 INTRODUCTION 2 13.2 INFRASTRUCTURE FOR VOICE AND DATA NETWORKS 3 13.2.1 Building Communications Room 3 13.2.2 Floor Communications Rooms 3 13.3 DATA NETWORKS 3

More information

Coaxial Cable Entry Panels, Coax and Grounding Connectors. Technical Note

Coaxial Cable Entry Panels, Coax and Grounding Connectors. Technical Note Coaxial Cable Entry Panels, Coax and Grounding Connectors Technical Note Coaxial Cable Entry Panels, Coax and Grounding Connectors Surge Protection Solutions for PTC 2 Coaxial Cable Entry Panels, Coax

More information

Specifying an IT Cabling System

Specifying an IT Cabling System Specifying an IT Cabling System This guide will help you produce a specification for an IT cabling system that meets your organisation s needs and gives you value for money. You will be able to give your

More information

DPS Preliminary Review: Verizon FIOS Customer Premises Installation NEC Compliance Issues

DPS Preliminary Review: Verizon FIOS Customer Premises Installation NEC Compliance Issues DPS Preliminary Review: Verizon FIOS Customer Premises Installation NEC Compliance Issues OVERVIEW A key aspect of providing telecommunications services is the provision of those services in a safe and

More information

Introduction to Data Centre Design

Introduction to Data Centre Design Introduction to Data Centre Design Barry Elliott BSc RCDD MBA CEng Earthing, grounding and bonding November 09 Earthing what s the point Safety from electrical hazards Reliable signal reference within

More information

Electrical Contractors Association

Electrical Contractors Association Electrical Contractors Association Presents BS 7671 2008: Amendment No 1 BS 7671: 2008 Amendment No 1, 2011 IEE Wiring Regulations Now called IET Wiring Regulations History 1882 first edition of the Wiring

More information

SUBJECT: CENELEC VOTE FINAL DRAFT PR EN 50173-1 INFORMATION TECHNOLOGY -GENERIC CABLING SYSTEMS PART 1:GENERAL REQUIREMENTS AND OFFICE AREAS

SUBJECT: CENELEC VOTE FINAL DRAFT PR EN 50173-1 INFORMATION TECHNOLOGY -GENERIC CABLING SYSTEMS PART 1:GENERAL REQUIREMENTS AND OFFICE AREAS Private circulation BCBritish Standards BSI British Standards 389 Chiswick High Road London W4 4AL Tel: 020 8996 9000 Fax: 020 8996 7448 Web: http://bsi-global.com DIRECT Tel: +44(0) 20 8996 7416 Fax:

More information

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1 BLACK BOX NETWORK SERVICES OCTOBER 2007 MT195A-T1 MT196A-E1 T1/E1 Link Extenders Important This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved

More information

European Normative EN50173-1. system

European Normative EN50173-1. system European Normative EN50173-1 for generic/structured cabling system Pietro Nicoletti Studio Reti s.a.s piero[at]studioreti.it www.studioreti.it Cabl-New-2003-Engl - 1 P. Nicoletti: see note pag. 2 Copyright

More information

Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012

Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012 Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012 CHANGE CONTROL RECORD: Version Date Action* Reason for Revision

More information

Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time

Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time Trial Exams C Standards and Regulations Examination No: GH-08-C- This test is intended to gauge your knowledge of essential information contained within AS/CA S009:2013. To qualify for an allpication to

More information

PerseveranceWorks. 38 Kingsland Road, London E2 8DD, UK

PerseveranceWorks. 38 Kingsland Road, London E2 8DD, UK PerseveranceWorks 38 Kingsland Road, London E2 8DD, UK Perseverance Works (PW) and Printing House Yard (PHY) are seeking a supplier for the provision of direct fibre access and data transport services

More information

User Manual Revision 2.201 English

User Manual Revision 2.201 English Document code: MN67117_ENG Revision 2.201 Page 1 of 14 User Manual Revision 2.201 English CANopen Repeater Small (Order Code: HD67117 HD67117M HD67117-M12 HD67117R) HD67117 HD67117M HD67117-M12 HD67117R

More information

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable June 10, 2010 Contributors: Yinglin (Frank) Yang CommScope, Inc. Charles Seifert Ixia Ethernet Alliance 3855 SW 153 rd

More information

Dat Da a t Cen t Cen er t St andar St d andar s d R o R undup o BICSI, TIA, CENELEC CENELE, ISO Steve Kepekci, RCDD

Dat Da a t Cen t Cen er t St andar St d andar s d R o R undup o BICSI, TIA, CENELEC CENELE, ISO Steve Kepekci, RCDD Data Center Standards Roundup BICSI, TIA, CENELEC, ISO Steve Kepekci, RCDD Introduction Regardless of business activity or size, all information technology (IT) groups have similar needs Provide secure,

More information

with Component Rating A Simple Perspective

with Component Rating A Simple Perspective Cat-6A UTP and Shielded with Component Rating A Simple Perspective Asef Baddar RCDD, DCD Sr. Technical Manager Leviton Middle East Category Specifications Agenda Terminology International & North America

More information

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications 3M Telecommunications Solutions for Networks Volition Network Solutions Leading the way in Network Migration through Innovative Connectivity Solutions Innovation The Broadband Migration Path 3M TM Volition

More information

Giganet Copper Cabling Training

Giganet Copper Cabling Training Giganet Copper Cabling Training Giganet Certified Installer Course 5/14/2012 This manual has been produced as supporting documentation for the Giganet Fibre Optic Certification Course. Course attendees

More information

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS: PRODUCT DATASHEET & APPLICATIONS GUIDE BASEC APPROVED AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2

More information

A guide to connecting to fibre optic networks for homeowners, architects, builders and developers.

A guide to connecting to fibre optic networks for homeowners, architects, builders and developers. A guide to connecting to fibre optic networks for homeowners, architects, builders and developers. Chorus is New Zealand s largest telecommunications utility company. We maintain and build the local access

More information

PXL-250: Network Wiring

PXL-250: Network Wiring This document provides the network wiring requirements for a PXL-250 access control network. Network Requirements The PXL-250 uses a half-duplex, RS-485 communication bus. Per the RS-485 specification,

More information

Chapter 9. Bonding and Grounding

Chapter 9. Bonding and Grounding Chapter 9 Bonding and Grounding Objectives Describe why the cable should be bonded Describe bonding and grounding procedures Define Bonding and Grounding Explain Safety Benefits and intent of bonding and

More information

108-93018 05 APR 2016 Rev M

108-93018 05 APR 2016 Rev M Product Specification 108-93018 05 APR 2016 Rev M Copper LAN Cable 1. SCOPE 1.1. Content This specification describes the general requirements for CommScope copper LAN cable. 2. APPLICABLE DOCUMENTS The

More information

Accelerating Light. Copper Cabling Solutions. Category 6A

Accelerating Light. Copper Cabling Solutions. Category 6A Accelerating Light Copper Cabling Solutions Category 6A Category 6A Copper Cabling Solutions Fibernet designs and manufactures premium, high performance copper communication infrastructure and connectivity

More information

SANS 10142-1 : 2008 CODE OF PRACTICE THE WIRING OF PREMISES Part 1 : Low Voltage Installation

SANS 10142-1 : 2008 CODE OF PRACTICE THE WIRING OF PREMISES Part 1 : Low Voltage Installation SANS 10142-1 : 2008 CODE OF PRACTICE THE WIRING OF PREMISES Part 1 : Low Voltage Installation 4 Compliance Proof of Compliance (Sub clause 4.1.1) The SABS safety mark The SABS approved performance mark

More information

Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8

Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8 Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC by Paul Kish NORDX/CDT Chair TIA TR 41.8 Outline Market trends Standards development where we were where we are where we are going Beyond Category

More information

HARTING Ethernet Cabling 8-poles Overview

HARTING Ethernet Cabling 8-poles Overview Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs

More information

ANSI/TIA/EIA - 568-A, Commercial Building Telecommunications Cabling Standard.

ANSI/TIA/EIA - 568-A, Commercial Building Telecommunications Cabling Standard. WIRING STANDARD INTRODUCTION This standard defines a telecommunications wiring system for North Dakota State Agencies, offices or buildings that will support a multi-product environment. The purpose of

More information

10 Gigabit Ethernet over copper: Unshielded, unprotected?

10 Gigabit Ethernet over copper: Unshielded, unprotected? Technical Article 10 Gigabit Ethernet over copper: Unshielded, unprotected? Copyright 2005 Reichle & De-Massari AG (R&M). All rights reserved. Transmission and reproduction of this publication or parts

More information

Grounding Demystified

Grounding Demystified Grounding Demystified 3-1 Importance Of Grounding Techniques 45 40 35 30 25 20 15 10 5 0 Grounding 42% Case 22% Cable 18% Percent Used Filter 12% PCB 6% Grounding 42% Case Shield 22% Cable Shielding 18%

More information

Nexus Technology Review -- Exhibit A

Nexus Technology Review -- Exhibit A Nexus Technology Review -- Exhibit A Background A. Types of DSL Lines DSL comes in many flavors: ADSL, ADSL2, ADSL2+, VDSL and VDSL2. Each DSL variant respectively operates up a higher frequency level.

More information

Data Centre Link Survey

Data Centre Link Survey Data Centre Link Survey Alan Flatman Principal Consultant LAN Technologies, UK a_flatman@compuserve.com Contribution to IEEE 82.3ba Higher Speed Ethernet Task Force 23-25 Jan 8, Portland, OR Survey Objectives

More information

CompactLogix Power Supplies Specifications

CompactLogix Power Supplies Specifications Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO/IEC 11801 Second edition 2002-09 Information technology Generic cabling for customer premises Reference number ISO/IEC 11801:2002(E) INTERNATIONAL STANDARD ISO/IEC 11801 Second

More information

Project files. Customer copy Legrand copy

Project files. Customer copy Legrand copy 20 years warranties Project files Structured cabling Systems categories 6A, 6 & 5e Customer copy Legrand copy TO BENEFIT FROM LEGRAND WARRANTIES 1 Complete and sign the Identity document: Worksite details*,

More information

LANscape Solutions. FutureCom Shielded Copper Cabling Systems 2008/09

LANscape Solutions. FutureCom Shielded Copper Cabling Systems 2008/09 LANscape Solutions Shielded Copper Cabling Systems 2008/09 1 Introduction 3 2 F 13 3 10 TEN e 53 4 10 TEN 77 5 E 103 6 D 135 7 Data Centre Solutions 161 8 Hardware 181 9 Telephone / ISDN Products 213

More information

The impact of the New EMC Directive 2004/108/EC

The impact of the New EMC Directive 2004/108/EC The impact of the New EMC Directive 2004/108/EC Presentation by Damon High Presentation Overview Brief overview of Electromagnetic Interference and Electromagnetic Compatibility EMC Directive and UK Legislation

More information

AN-3 SEVEN KEY CONSIDERATIONS BEFORE YOU START YOUR SLIC OR FXS PHONE LINE INTERFACE DESIGN

AN-3 SEVEN KEY CONSIDERATIONS BEFORE YOU START YOUR SLIC OR FXS PHONE LINE INTERFACE DESIGN AN-3 SEVEN KEY CONSIDERATIONS BEFORE YOU START YOUR SLIC OR FXS PHONE LINE INTERFACE DESIGN By Joe Randolph Introduction The conventional 2-wire analog phone line that telephone companies provide to residential

More information

DATA CENTRES POWERED BY EXCEL

DATA CENTRES POWERED BY EXCEL DATA CENTRES POWERED BY EXCEL MAXIMISE EFFICIENCY BOOST PERFORMANCE INCREASE R.O.I. WITHOUT COMPROMISE Excel is a world-class premium performance end-to-end infrastructure solution. Designed, manufactured,

More information

Network Design. Yiannos Mylonas

Network Design. Yiannos Mylonas Network Design Yiannos Mylonas Physical Topologies There are two parts to the topology definition: the physical topology, which is the actual layout of the wire (media), and the logical topology, which

More information

PROFINET. Design Guideline

PROFINET. Design Guideline PROFINET Design Guideline Version 1.04 November 2010 PROFINET Design Guideline Version 1.04 November 2010 Order No: 8.062 Page 1 / 190 Introduction PROFINET Order No: 8.062 Identification: TC2-10-0002

More information

1.3. The network element must have the ability to be configured in a point to point, point to multi point, and daisy chain configuration.

1.3. The network element must have the ability to be configured in a point to point, point to multi point, and daisy chain configuration. DESCRIPTION This work shall consist of furnishing and installing 10/100 Ethernet over Twisted Pair (TWP) Copper Modems in accordance with the contract documents and as directed by the Engineer. MATERIALS

More information

HARTING mcon 3000 Introduction and features

HARTING mcon 3000 Introduction and features Introduction and features HARTING mcon 3000 es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features The fully managed es of the product family HARTING mcon

More information

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations) DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations) DETAILS OF THE CLEINT Client and address ADDRESS OF THE INSTALLATION Installation

More information

FOM-5A, 6A. Asynchronous Fiber Optic Modem

FOM-5A, 6A. Asynchronous Fiber Optic Modem FOM-5A, 6A Asynchronous Fiber Optic Modem FEATURES Asynchronous transmission at up to 19.2 kbps Transmission range up to 3 km (1.8 mi), regardless of data rate Full- or half-duplex Transfers one control

More information

ENGINEERING COMMITTEE

ENGINEERING COMMITTEE ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 02 2006 Specification for F Port, Female, Indoor NOTICE The Society of Cable Telecommunications Engineers (SCTE)

More information

Data Center Standards Making Progress on Many Fronts. Jonathan Jew J&M Consultants, Inc jew@j-and-m.com

Data Center Standards Making Progress on Many Fronts. Jonathan Jew J&M Consultants, Inc jew@j-and-m.com Data Center Standards Making Progress on Many Fronts Jonathan Jew J&M Consultants, Inc jew@j-and-m.com J&M Consultants - 2008 Speaker Jonathan Jew Co-chair TIA TR-42.1.1 Data Center working group ANSI/TIA-942

More information

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference : 9010709-03

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference : 9010709-03 MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE USER GUIDE Document reference : 9010709-03 If you have questions about the MDM192 or desire assistance, contact ETIC TELECOMMUNICATIONS at the following

More information

If you want to get an official version of this User Network Interface Specification, please order it by sending your request to:

If you want to get an official version of this User Network Interface Specification, please order it by sending your request to: This specification describes the situation of the Proximus network and services. It will be subject to modifications for corrections or when the network or the services will be modified. Please take into

More information

MYTHBUSTING Takes on Shielded Cabling

MYTHBUSTING Takes on Shielded Cabling MYTHBUSTING Takes on Shielded Cabling Herb Congdon Brian Davis Objectives Take on myths of shielded cabling and use modern-day science to show what's real and what's fiction - through trial and error actually

More information

EMC OF INSTALLATIONS AND RECOMMENDED CABLE SEPARATIONS

EMC OF INSTALLATIONS AND RECOMMENDED CABLE SEPARATIONS EMC Technical Information EMC OF INSTLLTIONS ND RECOMMENDED CBLE SEPRTIONS Technology Installation Services Providing a fully integrated installation service for the Computer/Telecommunications Industry

More information

Interfacing electrification and system reliability. Earthing of AC and DC railways 4,10,13

Interfacing electrification and system reliability. Earthing of AC and DC railways 4,10,13 Interfacing electrification and system reliability Roger White Professional Head of Electrification and Plant Rail Abstract Integration is the term given to ensuring that the different elements of an electrified

More information

Customer Interface Publication: KCH CIP002. Public Switched Telephone Network (PSTN)

Customer Interface Publication: KCH CIP002. Public Switched Telephone Network (PSTN) Customer Interface Publication: KCH CIP002 Public Switched Telephone Network (PSTN) Technical Characteristics of the Private Branch Exchange (PBX) Analogue Multi-Line Interface Issue: 1.1 August 2007 The

More information

Excel Pre-terminated Copper and Fibre Optic Systems

Excel Pre-terminated Copper and Fibre Optic Systems Excel Pre-terminated Copper and Fibre Optic Systems Excel is a world-class premium performing end-to-end infrastructure solution - designed, manufactured, supported and delivered - without compromise.

More information

ANSI/TIA/EIA-570. 570-A A Revisited. Residential Telecommunications Cabling Standard (Draft 6/22/99) Larry L. Hamlin, RCDD

ANSI/TIA/EIA-570. 570-A A Revisited. Residential Telecommunications Cabling Standard (Draft 6/22/99) Larry L. Hamlin, RCDD BICS I CABLING INSTALLATION PROGRAM ANSI/TIA/EIA-570 Residential Telecommunications Cabling Standard (Draft 6/22/99) Larry L. Hamlin, RCDD Copyright BICSI, October 1999 -A Revisited 1.1 Purpose standardize

More information

General Installation Guide. April 2014 v2.0

General Installation Guide. April 2014 v2.0 General Installation Guide April 2014 v2.0 This document is intended to provide general guidance on LAN cabling infrastructure design & installation good practices and for compliance to NCS warranty application

More information

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01 ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions

More information

HARTING mcon 1000 Introduction and features

HARTING mcon 1000 Introduction and features Introduction and features HARTING mcon 1000 es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features Supporting Ethernet (10 Mbit/s), Fast Ethernet (100 Mbit/s)

More information

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D ELECTRONICS AB DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D & HIGH&VOLTAGE& FIXED&GAIN& BROADBAND & 800Vpp&60mA& 100x& DC&to&ca&200&kHz & LOW&OUTPUT&IMPEDANCE& HIGH&SLEW&RATE &

More information

Network Topologies. Network Topologies

Network Topologies. Network Topologies Network Topologies LANs and WANs - Geographical coverage LANs A single geographical location, such as office building, school, etc Typically High speed and cheaper. WANs Spans more than one geographical

More information

The easy way to build switchgear and controlgear assemblies in compliance with the regulations

The easy way to build switchgear and controlgear assemblies in compliance with the regulations The easy way to build switchgear and controlgear assemblies in compliance with the regulations A guide for partially type-tested switchgear and controlgear assemblies in compliance with EN 60 439 What

More information

This draft amendment A1, if approved, will modify the Technical Basis for Regulation TBR 14 (1994)

This draft amendment A1, if approved, will modify the Technical Basis for Regulation TBR 14 (1994) TECHNICAL TBR 14 pr A1 BASIS for June 1995 REGULATION Source: ETSI TC-BTC Reference: RTBR/BTC-02066 ICS: 33.020, 33.040.40 Key words: ONP, leased line This draft amendment A1, if approved, will modify

More information

White Paper: Electrical Ground Rules

White Paper: Electrical Ground Rules Acromag, Incorporated 30765 S Wixom Rd, Wixom, MI 48393 USA Tel: 248-295-0880 Fax: 248-624-9234 www.acromag.com White Paper: Electrical Ground Rules Best Practices for Grounding Your Electrical Equipment

More information

HV Submarine Cable Systems Design, Testing and Installation

HV Submarine Cable Systems Design, Testing and Installation HV Submarine Cable Systems Design, Testing and Installation CIGRE Ireland Technical Seminar 6 th October 2010 Robert Donaghy Senior Consultant Engineer, ESB International Presentation Overview Applications

More information

Customer Interface Publication: KCH CIP015. Technical Characteristics of the Privateline analogue leased line interfaces

Customer Interface Publication: KCH CIP015. Technical Characteristics of the Privateline analogue leased line interfaces Customer Interface Publication: KCH CIP015 Technical Characteristics of the Privateline analogue leased line interfaces Issue: 1.1 August 2007 The information in this document is provided in accordance

More information

ENGINEERING COMMITTEE Energy Management Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 210 2015

ENGINEERING COMMITTEE Energy Management Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 210 2015 ENGINEERING COMMITTEE Energy Management Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 210 2015 Performance Metrics for Energy Efficiency & Functional Density of Cable Data Generation, Storage, Routing,

More information

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC) http://www.iec.

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC) http://www.iec. EMC STANDARDS The EMC standards that a particular electronic product must meet depend on the product application (commercial or military) and the country in which the product is to be used. These EMC regulatory

More information

NUIG Campus Network - Structured Cabling System Standards Information s Solutions & Services (ISS)

NUIG Campus Network - Structured Cabling System Standards Information s Solutions & Services (ISS) NUIG Campus Network - Structured Cabling System Standards Information s Solutions & Services (ISS) Revision date 28 th January 2014 The purpose of this document is to assist Building Refurbishment and

More information

Business Customer Demarcation Information

Business Customer Demarcation Information Building Industry Consulting Service (BICS) Business Customer Demarcation Information The intent of this document is to clearly define Communications terminology and deployment with reference to business

More information

4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Ethernet Switch Wide Temperature

4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Ethernet Switch Wide Temperature 4-Port 10/Mbps with + 1-Port FX Industrial Ethernet Switch Wide Temperature 15 F Fiber Optic Link Capability for Flexible Distance Extension The series equips one Base-FX port that provides more flexibility

More information

Patch Cords / Cable / Cable Assemblies. Patch. Cords/Cable/ Premise Connectivity Systems. Cable Assemblies

Patch Cords / Cable / Cable Assemblies. Patch. Cords/Cable/ Premise Connectivity Systems. Cable Assemblies Patch Cords / Cable / Cable Assemblies Premise Connectivity Systems Patch Cords/Cable/ Cable Assemblies w w w. s i g n a m a x. c o m Category 6A 10G Patch Cords C1 Patch Panels and Cross- Category 6 Patch

More information

Copper Pre-terminated Assemblies

Copper Pre-terminated Assemblies Copper Pre-terminated Assemblies Copper Pre-Terminated Trunk Assemblies Overview Copper Pre-Terminated trunk assemblies are the perfect solution for Enterprise / Premise & Data Centre applications where

More information

Data Centre Cabling. 20 August 2015 Stefan Naude RCDD The SIEMON Company

Data Centre Cabling. 20 August 2015 Stefan Naude RCDD The SIEMON Company Data Centre Cabling 20 August 2015 Stefan Naude RCDD The SIEMON Company Agenda 1. Data Centre Standards 2. The Need for Speed 3. Copper in the Data Centre 4. Fibre in the Data Centre 5. Top of Rack vs

More information

Local Area Network By Bhupendra Ratha, Lecturer School of Library and Information Science Devi Ahilya University, Indore Email: bhu261@gmail.com Local Area Network LANs connect computers and peripheral

More information

THE LIGHTNING PROTECTION INTERNATIONAL STANDARD

THE LIGHTNING PROTECTION INTERNATIONAL STANDARD THE LIGHTNING PROTECTION INTERNATIONAL STANDARD Prof.-Dr-Eng. Christian Bouquegneau, Chairman of IEC TC81 (Lightning Protection), Pro-rector of the Faculté Polytechnique de Mons (Belgium) Abstract The

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 62305-3 Edition 2.0 2010-12 colour inside Protection against lightning Part 3: Physical damage to structures and life hazard INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE

More information

FWA - technology and benefit

FWA - technology and benefit FWA - technology and benefit Professor Torleiv Maseng adj. Professor radio communications Department of Electroscience ( Inst. för Elektrovetenskap), Lund University, LTH FWA: Point to multipoint systems

More information

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] HARTING PushPull Connectors [on page 22] System cables [on page 24] Panel feed-throughs [on

More information

Listed are common requirements that apply to existing solar installations when altered, added to or reconfigured.

Listed are common requirements that apply to existing solar installations when altered, added to or reconfigured. SOLAR ALTERATIONS REQUIREMENTS August 2015 These requirements address typical alterations to solar installations; they cannot address every scenario. In Victoria, an alteration to a solar installation

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

For business. Wiring your business for broadband. What happens when copper is required?

For business. Wiring your business for broadband. What happens when copper is required? For business Wiring your business for broadband Your cabling requirements are dependent on the size and complexity of your business. Smaller businesses should follow the wiring recommendations for residential

More information

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only. s For UK only RX39.1 and the applications package SP-03 are sold in the United Kingdom only. 3 876 3876P01 RX Room controller Communicating controllers for fan-coil applications SP-03 RX39.1 The RX39.1

More information

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide 31007950 7/2009 ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide 7/2009 31007950.02 www.schneider-electric.com NOTICE Read these instructions carefully, and look at the equipment to become

More information

Networks. The two main network types are: Peer networks

Networks. The two main network types are: Peer networks Networks Networking is all about sharing information and resources. Computers connected to a network can avail of many facilities not available to standalone computers: Share a printer or a plotter among

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Broadband jargon buster

Broadband jargon buster Better business is better connected Leeds Bradford broadband connection voucher scheme Broadband jargon buster #superfastbritain www.superconnectedleedsbradford.co.uk Terminology Buster These are some

More information

CE Marking and Technical Standardisation

CE Marking and Technical Standardisation GAMBICA Technical Guide CE Marking and Technical Standardisation Guidelines for application to Electrical Power Drive Systems Edition 4 : 2015 CE Marking and Technical Standardisation Guidelines for application

More information

270526-TC Grounding and Bonding for Telecommunications Systems

270526-TC Grounding and Bonding for Telecommunications Systems 270526-TC Grounding and Bonding for Telecommunications Systems Part 1 - General Related Documents The following related sections of the OT standards shall also be applicable to this section. OT Engineer

More information

Highlights: ISO/IEC SC25/WG3 Meeting Berlin: 02-06 06 May 2011. - Customer Premises Cabling -

Highlights: ISO/IEC SC25/WG3 Meeting Berlin: 02-06 06 May 2011. - Customer Premises Cabling - 1 ISO/IEC SC25/WG3 Meeting Berlin: 02-06 06 May 2011 - Customer Premises Cabling - Highlights: 1. ISO/IEC 24764 Data Centre Cabling Am.1 2. ISO/IEC 14763-2 Plan. & Install. final draft 3. ISO/IEC 14763-3

More information

Power over Ethernet technology for industrial Ethernet networks

Power over Ethernet technology for industrial Ethernet networks Power over Ethernet technology for industrial Ethernet networks Introduction Ethernet networking has grown beyond office and home usage to become a very successful protocol suite used in many industrial

More information