Air C r Conditioning & H g & Heat Pu at Pump Pro Produc u ts Revised Aug. 08

Size: px
Start display at page:

Download "Air C r Conditioning & H g & Heat Pu at Pump Pro Produc u ts Revised Aug. 08"

Transcription

1 ir Conditioning i i &H Heat tpump Products Revised ug. 08

2 SNYO ir Conditioners & Heat Pumps Btu/h 9,000 12,000 18,000 24,000 26,000 30,000 36,000 42,000 Type Standard Low mbient Standard Low mbient Standard Low mbient Standard Low mbient Low mbient Low mbient Low mbient Low mbient 26KS72R 36KS72R MODEL (System) 09KS71 09KLS71 12KS71 12KLS71 18KS72 18KLS72 24KS72 24KLS72 30KS72R 36TW72R 42TW72R 26TW72R 42XW72R 26XW72R 36XW72R Wall Mounted KS0971 KS1271 KS1872 KS2472 KHS2672R KHS3072R KHS3672R Ceiling Suspended THW2672R THW3672R THW4272R IR CONDITIONER Ceiling Recessed Concealed Duct XHW2672R UHW2672R XHW3672R UHW3672R XHW4272R Outdoor C0971 CL0971 C1271 CL1271 C1872 CL1872 C2472 CL2472 C2672R C3072R C3672R C4272R MODEL (System) 09KHS71 12KHS71 18KHS72 24KHS72 26KHS72R 26THW72R 26XHW72R 26UHW72R 30KHS72R 36KHS72R 36THW72R 36XHW72R 42THW72R 42XHW72R Wall Mounted KHS0971 KHS1271 KHS1872 KHS2472 KHS2672R KHS3072R KHS3672R HET PUMP WITHOUT HETER Ceiling Suspended Ceiling Recessed Concealed Duct THW2672R XHW2672R UHW2672R THW3672R XHW3672R UHW3672R THW4272R XHW4272R Outdoor CH4272R CH0971 CH1271 CH1872 CH2472 CH2672R CH3072R CH3672R MODEL (System) 26KHHS72R 26THHW72R 36THHW72R HET PUMP WITH HETER Wall Mounted Ceiling Suspended Outdoor KHHS2672R THHW2672R THHW3672R CH2672R CH3672R 2

3 CONTENTS SNYO LineUp p2 3 Feature Chart p4 Model Identification System 18 K H S 7 2 Capacity in BTU/h Type K: Wall Mounted T: Ceiling Suspended X: 4way Ceiling Recessed U: Conceiled Duct M: MulitiZone Flexi Multi Inverter IR CONDITIONER Voltage: 1:115V 2: 208/230V Component Type K: Wall Mounted T: Ceiling Suspended X: 4way Ceiling Recessed U: Conceiled Duct C: Outdoor unit Model Series No. S: Wireless remote Control W: Wired remote Control H: Heater Function M: MulitiZone H: Heat Pump L: Low mbient K H S187 2 Voltage: 1:115V 2: 208/230V Model Series No. Capacity in BTU/h S: Wireless remote Control W: Wired remote Control H: Heater Function H: Heat Pump KHS1872 Indoor unit 18KHS72 Master model No. (System) + CH1872 Outdoor unit Btu/h 7,000 9,000 12,000 18,000 24,000 Type Standard Low mbient Standard Low mbient Standard Low mbient Standard Low mbient Standard Low mbient Wall Mounted KMS0772 KMS0972 KMS1272 KMS1872 KMS2472 Btu/h 19,000 24,000 31,000 Type Standard Low mbient Standard Low mbient Standard Low mbient Outdoor NOTE: ll 7 series are R410 models Up to 3 Rooms Up to 3 Rooms Up to4 Rooms CM1972 CLM1972 CM2472 CLM2472 CM3172 CLM3172 Features p5 Options p6 Benefits p7 WallMounted /C 09KS71/09KLS71 12KS71/12KLS71 18KS72/18KLS72 24KS72/24KLS72 26KS72R 30KS72R 36KS72R p8.9 WallMounted H/P 09KHS71 12KHS71 18KHS72 24KHS72 26KHHS72R 26KHS72R 30KHS72R 36KHS72R p10.11 Flexi Multi Btu Btu Btu p1215 FlexiMulti Combination Tables p16 FlexiMulti Combination Tables p17 HET PUMP Btu/h 7,000 9,000 12,000 18,000 24,000 Wall Mounted Btu/h 19,000 24,000 31,000 Outdoor KMHS0772 KMHS0972 KMHS1272 KMHS1872 KMHS2472 Up to 3 Rooms Up to 3 Rooms Up to4 Rooms Ceiling Suspended 26TW72R 26THW72R 36TW72R 42TW72R 36THW72R 42THW72R 26THHW72R 36THHW72R p18.19 Ceiling Recessed 26XW72R 36XW72R 42XW72R 26XHW72R 36XHW72R 42XHW72R p20.21 Concealed Duct 26UW72R 36UW72R 26UHW72R 36UHW72R p22 CMH1972 CMH2472 CMH3172 System Options & ccessories p23 Other Specs 3 p24

4 MODEL FETURE CHRT : Option Wall Mounted Ceiling Suspended IR CONDITIONERS 09KS71 12KS71 18KS72 24KS72 09KLS71 12KLS71 18KLS72 24KLS72 LOWMBIENT IR CONDITIONERS 26KS72R 30KS72R 36KS72R 26TW72R 36TW72R 42TW72R HET PUMPS W/ O HETER 09KHS71 26KHS72R 12KHS71 18KHS72 30KHS72R 24KHS72 36KHS72R 26THW72R 36THW72R 42THW42R HET PUMPS W/ HETER 26KHHS72R 26THHW72R 36THHW72R Ceiling Recessed 26XW72R 36XW72R 42XW72R 26XHW72R 36XHW72R 42XHW72R Concealed Duct patite Filter Negative Ion Generator Controlled Operation Wireless Remote Control Wired Remote Control SelfDiagnosing Function Dry Mode 3 Fan Speeds and Fan Operation ir Sweep Control Louver Control and Changeover Night Setback Mode for and Hot Start System 24Hour Clock with ON/OFF Program Timer 72Hour ON/OFF Timer 1Hour OFF Timer Weekly Timer System Controller ntimold Filter Filter Sign Restart Function after Power Failure Fresh ir Intake Branch Extension BuiltIn Drain Pump Low mbient Operation Electric Expansion Valve ODP=0 Refrigerant 26UW72R 36UW72R 26UHW72R 36UHW72R Quiet Mode 4

5 Features Controlled Operation control ensures that the temperature and humidity levels in the room are always comfortable. Wireless Remote Control Sanyo s infrared Remote Control with and easy to read LCD Display, gives the user the capability to adjust & set: temperature, sweep (louver control), fan speeds, timer, night setback and more, for complete automatic operation. Dry Mode By coupling compressor and fan operation, intermittent operation can be precisely controlled according to room temperature, so that air is efficiently dehumidified. 3 Fan Speeds and Fan Operation Convenient microprocessor control automatically adjusts fan speed to High, Medium or Low. ccording to room temperature to maintain a comfortable airflow throughout the room. ir Sweep Control The air sweep function moves the louver up and down in the air outlet, directing air in a sweeping motion around the room and providing comfort in every corner. Cool/Dry Mode Heat Mode Flap Louver Control Louver can be manually set to the desired angle by remote control. Negative Ions Generator The negative ions generator fills your room with negative ions throughout the year. *Ion generating power over 100,000 parts/cc and Changeover fter setting the temperature and functions you desire, just relax. If the room temperature is higher than the set temperature, cooling operation begins. If the room temperature is lower than the set temperature, heating operation begins. During normal thermostat cycle operation, cooling and heating operations automatically change in accordance with set temperature, time and room temperature. (Heat Pump unit only) 1hour OFF Timer When this button is pushed either while the unit is operating or while it is stopped, the unit will operate for one hour and then switch off automatically. 24hour Clock with ON/OFF Program Timer The remote control unit allows you to set a wide variety of timerbased operations. Such functions include automatic ON/OFF with a timer setting, same time ON/OFF every day, ON timer, OFF timer and Combination timer. ON/OFF Timer Remote controller ON/OFF timer can be set to 0.5 hour gradations (max. 72 hours). Night Setback Mode for and and DRY Mode: With the Night Setback Mode, the air conditioner automatically raises the setting temperature 2 F after 30 minutes, and then another 2 F after the next 30 minutes. Mode: With the Night Setback Mode, the setting temperature is automatically lowered 4 F after 30 minutes, and then another 4 F after the next 30 minutes. This saves energy without sacrificing comfort and is ideal for gentle cooling and heating. Setting temperature Setting temperature In and DRY Mode 2 F 30 min. 30 min. Press the NIGHT SETBCK button Time In Mode Restart Function after Power Failure This feature allows the system to automatically resume operation at its preset program, after power is restored from a power failure. Hot Start System Right from the start, air is warm and comfortable. The Hot Start System prevents any cold blasts at the beginning while the heat pump is warming up. (Heat pump unit only) ir Clean patite Filter patite or calcium phosphate is highly effective in trapping germs, mites and mite excrement, pollen, dirt and dust, and cigarette odor. The triple layered air clean apatite filter consists of antibacterial, deodorizing, and dustcollecting sections that maintain healthy, clean air in your room. 4 F 2 F 4 F Press the 30 min. 30 min. NIGHT SETBCK button Time ntimold Filter Filter is treated with antimold coatings to prevent mold or bacteria from occurring. BuiltIn Drain Pump Max. head 20 from the discharge of the indoor unit. Condensate pump is only for allowing drain line to meet minimum gravity flow requirements. Electric Refrigerant Control Valve The circulation volume of the refrigerant is controlled by a pulse type electric control valve. In order to attain optimum efficiency, when the power is switched ON, the opening degree of the electric control valve is controlled between 90 and 480 steps. Quiet Mode LOW, low fan speed for extra quiet operation. Filter Sign Filter sign informs you when filter maintenance is necessary. 2,500 hrs: X, Ttypes 150 hrs: Ktype (RCSTM80BG) SelfDiagnosing Function Details of previous warnings are stored and can be verified on the liquid crystal display. This makes it easier to diagnose malfunctions, greatly reducing service labor. (Wired remote controller) (Example of RCSTM80BG) 5

6 Options for Models Btu s and Larger Wired s Simple (RCSKR1GB) Key Features (Simple Remote): Thin and Easy To Read Simple To Install and Use Can Be dapted for Use On ll ECOi Indoor Units Mode Fan Speed Control Set Temperature On/Off irflow Direction Perfectly Suited for pplications Where Simpler Functionality is Required (ie: Hotel Rooms, Nursing Homes, Offices) Key Features (Standard Remote/7 Day Timer): Thin and Easy To Read Simple To Install and Use Can Be dapted for Use On ll ECOi Indoor Units Fan Speed Control irflow Direction Operating Mode (//uto/dry/fan) Vacation Mode for Continued Energy Efficiencies RCSTM80BG Full 7 Day SetBack Functionality, With Up To 6 Time Periods/Day Full System Diagnostic Capability (Diagnostic History Provides Immediate View of System Past and Present.) System Controller (SHKC64UG) Multiple Zone Controllers. The ir Conditioning Gateway. Sanyo s system and intelligent controls are the central nervous system to the conditioning system. The gateway to all data, temperature and system diagnostics. The heart and soul of conditioning. Key Features (System Control): Controls Up To 64 Units Into 4 Individualized Zones larm and Operational Signal Output Single ccess Points for ll Connected Wired Remotes pplicable Unit Wireless Kseries Wireless s Xseries (Ceiling Recessed Type) For ll s Tseries (Ceiling Suspended Type) Useries Xseries Tseries BUILTIN TYPE Signal receiving unit can be installed in the outer panel of indoor unit. Control panel can be installed in the inside indoor unit. EXTERNL TYPE Separate type signal receiving unit. RCSSH1U RCSSH80UWL RCSBH80UWL s Functions Function System Setting Range ON/OFF Operation mode switch Dry Fan Temp setting Fan speed setting (Hi/Mid./Lo/uto) uto airflow direction setting uto flap rbitrary airflow direction setting Sweep (Flap swing) Sensor temp. display Selfdiagnostic function Central control (at hand inhibited) Group control Concurrent use with weekly timer, dry ( F) ( F) Timer System Controller (RCSTM80BG) (SHKC64UG) (Collective/Individual) (Individual) (Individual) (Individual) (Individual) (Individual) (Individual) * * (Up to 8 units) (Up to 16 groups) : Controllable : Uncontrollable NOTE: If you use both remote controller and system controller concurrently, both controllers can be used on a lastsignal priority basis. 6

7 Benefits High Efficiency systems up to 20 SEER Inverter Driven variable speed twin rotary compressors Precise compressor speed to match the building needs Quiet operation Designed to run longer periods at reduced speeds to improve dehumidification Quick and easy installation of indoor and outdoor units Wireless remote controllers available on all models Single Point Power Supply reduces installation costs 6 Year compressor warranty and 1 year parts warranty 9,000 24,000 Btu/h single zone wiring schematic Disconnect Switch (Field Supplied) 115 or208/ or 208/ VDC Signal 3 G G G Disconnect Switch (Field Supplied) Power Supply Ground 26,000 42,000 Btu/h single zone wiring schematic (control wiring to be 18/2 shielded; grounded on both ends) Flexi Multi wiring schematic ( example shown is with 3 indoor units) Indoor unit V 115 V 1215 VDC G G Indoor unit B V 115 V 1215 VDC B G G Disconnect Switch Field Supplied C V 115 V 1215 VDC C 208/230 VC (Single Phase) Power Supply G G 1 2 L1 L2 G Ground 7

8 WallMounted ir Conditioners Wireless 09KS71 / 09KLS71 12KS71 / 12KLS71 KS0971 KS1271 C0971 / CL0971 C1271 / CL1271 Wireless WSHBLE FRONT GRILLE 18KS72 / 18KLS72 24KS72 / 24KLS72 KS1872 KS2472 C1872 / CL1872 C2472 / CL2472 Only for 09KLS71, 12KLS71, 18KLS72, 24KLS72 Model No. Unit Model No. Performance & Electrical Ratings Capacity Btu/h Btu/h Moisture Removal High Pints/H Dry ir Flow Hi / Med / Low CFM SEER HSPF C Power Supply V, Phase, Hz Running mps Power Input W W Backup Heater kw Fuse or Circuit Breaker Capacity Features Controls Low mbient Control Wireless Fan Speeds Timer 8 09KS71 / 09KLS71 KS0971 C0971 / CL0971 9,000 (3,000~9,000) / 247 / V, 1PH, 60Hz 7.6 (2.5~7.6) 755 (250~755) 20 Wall Mounted ir Conditioners 12KS71 / 12KLS71 KS1271 C1271 / CL ,900 (3,000~11,900) / 259 / V, 1PH, 60Hz 10.9 (2.5~10.9) 1,090 (250~1,090) 20 18KS72 / 18KLS72 KS1872 C1872 / CL ,500 (4,000~17,500) / 470 / V, 1PH, 60Hz 7 / 7.7 (1.2~7.7) 1,500 / 1,500 (250~1,500) 20 09KLS71 Equip. 12KLS71 Equip. 18KLS71 Equip. Included Included Included Hi / Me / Lo & uto Hi / Me / Lo & uto Hi / Me / Lo & uto 1hr OFF and 1hr OFF and 1hr OFF and 24hr PROGRM 24hr PROGRM 24hr PROGRM ir Deflection Horizontal Vertical Manual Manual Manual ir Filter Refrigerant Refrigerant control Operation Sound In(Hi / Me / Lo/ Qt) db + patite R / 31 / 28 / 23 + patite R / 33 / 29 / 25 + patite R / 38 / 30 / 28 Outdoor(Hi) db Refrigerant Piping Type Discharge 1/4" Discharge 1/4" Discharge 1/4" Discharge Suction 3/8" Suction 3/8" Suction 1/2" Suction Refrigerant Pipe Length Ft. Max. 65Ft Max. 98Ft Elevation Difference** Outdoor bove Ft. Max. 23Ft Max. 23Ft Outdoor Below Ft. Max. 23Ft Max. 23Ft Dimensions & Weight Height 117/32" 219/16" 117/32" 219/16" 1123/32" 263/8" Width 3215/32" 2811/32" 3215/32" 2811/32" 4115/16" 3421/32" Depth 77/16" 107/16" 77/16" 107/16" 819/32" 117/32" Net Weight Lbs ** This is maximum elevation difference when the indoor unit is located above the outdoor unit. (Refer to the table on the back of the catalogue for more detail.) compressor parts R410 REFRIGERNT Inverter 24KS72 / 24KLS72 KS2472 C2472 / CL ,200 (4,000~24,200) / 541 / V, 1PH, 60Hz 10.8 / 12.1 (1.3~12.1) 2,355 / 2,355 (280~2,355) 20 24KLS71 Equip. Included Hi / Me / Lo & uto 1hr OFF and 24hr PROGRM Manual + patite R410 Control 47 / 44 / 41 / /4" Discharge Max. 131Ft 1123/32" 291/8" 4115/16" 357/16" 819/32" 1219/32"

9 WallMounted ir Conditioners C2672R Wireless (RCSSHIU) 26KS72R KHS2672R C3072R C3672R Wireless (RCSSHIU) 30KS72R 36KS72R KHS3072R KHS3672R Model No. Unit Model No. Performance & Electrical Ratings Capacity Btu/h Btu/h Moisture Removal High Pints/H Dry ir Flow Hi / Med / Low CFM SEER EER HSPF C Power Supply V, Phase, Hz Running mps Power Input W W Backup Heater kw Fuse or Circuit Breaker Capacity Features Controls Low mbient Control Wireless Wired Fan Speeds Timer ir Deflection Horizontal Vertical ir Filter Refrigerant Refrigerant control Operation Sound In(Hi / Me / Lo) db Outdoor(Hi) db Refrigerant Piping Type Discharge Suction Refrigerant Pipe Length Ft. Elevation Difference** Outdoor bove Ft. Outdoor Below Ft. Dimensions & Weight Height Width Depth Net Weight Lbs. Wall Mounted ir Conditioners 26KS72R KHS2672R C2672R 25,200 (9,500~25,200) / 475 / V, 1PH, 60Hz 15.3 / ,840 / 2, Builtin 0 F RCSSH1U (included) RCSTM80BG (optional) 3 and Control / Variable Option R / 42 / /64" 3023/32" 447/8" 37" 831/32" 133/8" KS72R KHS3072R C3072R 29,800 (9,500~29,800) / 740 / V, 1PH, 60Hz 17.7 / ,690 / 3, Builtin 0 F RCSSH1U (included) RCSTM80BG (optional) 3 and Control / Variable Option R / 42 / /16" 3023/32" 591/16" 37" 97/16" 133/8" ** This is maximum elevation difference when the indoor unit is located above the outdoor unit. (Refer to the table on the back of the catalogue for more detail.) compressor parts R410 REFRIGERNT Inverter 36KS72R KHS3672R C3672R 31,400 (9,500~31,400) / 710 / V, 1PH, 60Hz 17.9 / ,750 / 3, Builtin 0 F RCSSH1U (included) RCSTM80BG (optional) 3 and Control / Variable Option R / 44 / /16" 3023/32" 591/16" 37" 97/16" 133/8"

10 WallMounted Heat Pumps Wireless 09KHS71 12KHS71 KHS0971 KHS1271 CH0971 CH1271 WSHBLE FRONT GRILLE Wireless 18KHS72 24KHS72 KHS1872 KHS2472 CH1872 CH2472 bove models do not have back up heater Model No. Unit Model No. Performance & Electrical Ratings Capacity Btu/h Btu/h Moisture Removal High Pints/H Dry ir Flow Hi / Med / Low CFM SEER HSPF C Power Supply V, Phase, Hz Running mps Power Input W W Backup Heater kw Fuse or Circuit Breaker Capacity Features Controls Low mbient Control Wireless Fan Speeds Timer ir Deflection Horizontal Vertical ir Filter Refrigerant Refrigerant control Operation Sound In(Hi / Me / Lo / Qt) db Outdoor(Hi) db Refrigerant Piping Type Discharge Suction Refrigerant Pipe Length Ft. Elevation Difference** Outdoor bove Ft. Outdoor Below Ft. Dimensions & Weight Height Width Depth Net Weight Lbs KHS71 KHS0971 CH0971 9,000 (3,000~9,000) 12,200 (3,000~12,200) / 247 / V, 1PH, 60Hz 7.6 (2.5~7.6) 10.3 (2.6~10.3) 755 (250~755) 995 (250~995) 20 Builtin 0 F Included Hi / Me / Lo & uto 1hr OFF and 24hr PROGRM Manual R / 31 / 28 / /4" Discharge 3/8" Suction Max. 23Ft Max. 23Ft 117/32" 219/16" 3215/32" 2811/32" 77/16" 107/16" Wall Mounted Heat Pump 12KHS71 KHS1271 CH ,900 (3,000~11,900) 13,300 (3,000~13,300) / 259 / V, 1PH, 60Hz 10.9 (2.5~10.9) 11.7 (2.5~11.7) 1,090 (250~1090) 1,165 (250~1165) 20 Builtin 0 F Included Hi / Me / Lo & uto 1hr OFF and 24hr PROGRM Manual R / 33 / 29 / /4" Discharge 3/8" Suction Max. 65Ft Max. 23Ft Max. 23Ft 117/32" 219/16" 3215/32" 2811/32" 77/16" 107/16" ** This is maximum elevation difference when the indoor unit is located above the outdoor unit. (Refer to the table on the back of the catalogue) compressor parts R410 REFRIGERNT Inverter 18KHS72 KHS1872 CH ,500 (4,000~17,500) 20,400 (4,400~20,400) / 479 / V / 208V, 1PH, 60Hz 7 / 7.7 (1.2~7.7) 7.4 / 8.1 (1.3~8.1) 1,500 / 1,500 (250~1500) 1,575 / 1,575 (270~1575) 20 Builtin 0 F Included Hi / Me / Lo & uto 1hr OFF and 24hr PROGRM Manual R / 38 / 30 / /4" Discharge 1/2" Suction Max. 98Ft 1123/32" 263/8" 4115/16" 3421/32" 819/32" 117/32" KHS72 KHS2472 CH ,200 (4,000~24,200) 29,000 (4,400~29,000) / 541 / V / 208V, 1PH, 60Hz 10.8/12.1 (1.3~12.1) 12/13.5 (1.3~13.5) 2,355 / 2,355 (280~2355) 2,490 / 2,490 (290~2490) 20 Builtin 0 F Included Hi / Me / Lo & uto 1hr OFF and 24hr PROGRM Manual R / 44 / 41 / /4" Discharge Max. 98Ft 1123/32" 291/8" 4115/16" 357/16" 819/32" 1219/32"

11 WallMounted Heat Pumps KHS2672R Wireless (RCSSHIU) 26KHS72R CH2672R KHHS2672R CH2672R Wireless (RCSSHIU) 26KHHS72R KHS3072R KHS3672R CH3072R CH3672R Wireless (RCSSHIU) Model No. Unit Model No. Performance & Electrical Ratings Capacity Btu/h Btu/h Moisture Removal High Pints/H Dry ir Flow Hi / Med / Low CFM SEER HSPF C Power Supply V, Phase, Hz Running mps Power Input W W Backup Heater kw Fuse or Circuit Breaker Capacity Features Controls Low mbient Control Wireless Wired Fan Speeds Timer 30KHS72R 36KHS72R Wall Mounted Heat Pump W/ Heater 26KHHS72R KHHS2672R CH2672R 23,000 (9,500~23,000) 27,600 (8,000~27,600) / 460 / V / 208V 14.0 / / ,610 / 2,610 2,720 / 2, / Builtin 0 F RCSSH1U (included) RCSTM80BG (optional) 3 and Control / Variable 24hr/72hr 26KHS72R KHS2672R CH2672R 25,200 (9,500~25,200) 29,200 (8,000~29,200) / 475 / V / 208V 15.3 / / ,840 / 2,840 2,620 / 2, Builtin 0 F RCSSH1U (included) RCSTM80BG (optional) 3 and Control / Variable 24hr/72hr Wall Mounted Heat Pump 30KHS72R KHS3072R CH3072R 29,800 (9,500~29,800) 34,800 (8,000~34,800) / 740 / V / 208V 17.7 / / ,690 / 3,690 3,390 / 3, Builtin 0 F RCSSH1U (included) RCSTM80BG (optional) 3 and Control / Variable 24hr/72hr ir Deflection Horizontal Vertical ir Filter Refrigerant R410 R410 R410 Refrigerant control Operation Sound In(Hi / Me / Lo) db 45 / 42 / / 37 / / 42 / 38 Outdoor(Hi) db Refrigerant Piping Type Discharge Suction Refrigerant Pipe Length Ft. Elevation Difference** Outdoor bove Ft. Outdoor Below Ft. Dimensions & Weight Height 149/16" 3023/32" 1263/64" 3023/32" 149/16" 3023/32" Width 497/32" 37" 447/8" 37" 591/16" 37" Depth 89/32" 133/8" 831/32" 133/8" 97/16" 133/8" Net Weight Lbs ** This is maximum elevation difference when the indoor unit is located above the outdoor unit. (Refer to the table on the back of the catalogue) compressor parts R410 REFRIGERNT Inverter 36KHS72R KHS3672R CH3672R 31,400 (9,500~31,400) 36,400 (8,000~36,400) / 710 / V / 208V 17.9 / / ,750 / 3,750 3,320 / 3, Builtin 0 F RCSSH1U (included) RCSTM80BG (optional) 3 and Control / Variable 24hr/72hr R / 44 / /16" 3023/32" 591/16" 37" 97/16" 133/8"

12 FlexiMulti System s Fits with Various Sizes of Room and Life Style The multisystem type allows a single outdoor unit to be connected to 2 to 4 indoor units. It also solves the problem of limited installation space and does not clutter the exterior of your home. Wireless Included with each indoor KMS0772 / KMS0972 / KMS1272 KMHS0772 / KMHS0972 / KMHS1272 KMS1872 / KMS2472 KMHS1872 / KMHS2472 : Wall Mounted Type Model No. Power Source Running mpere Power Input W Capacity Btu/h Moisture Removal High Prints/H Unit Dimensions (HxWxD) inch Net Weight Lbs ir Circulation (High) CFM Operating Sound (H/L) db db Refrigerant Narrow Tube inch Tube Diameter Wide Tube inch Elevation Difference** Outdoor bove Ft. Outdoor Below Ft. Model No. Power Source Running mpere Power Input Capacity Btu/h Btu/h Moisture Removal High Prints/H Unit Dimensions (HxWxD) inch Net Weight Lbs ir Circulation (HIGH) CFM CFM Hi / Me / Lo / Qt db Operating Sound db Refrigerant Narrow Tube inch Tube Diameter Wide Tube inch Elevation Difference** Outdoor bove Ft. Outdoor Below Ft. 12 KMS , / 23 1/4" 3/8" KMHS ,500 8, / 30 / 27 /23 33 / 30 / 27 / 23 1/4" 3/8" Only KMS , "7/32" x 32"15/32" x 7"7/16" 11"23/32" x 41"15/16" x 8"19/32" / / / / 30 1/4" 3/8" Heat Pump KMHS ,000 12, KMS V / 208V, 1 PH, 60 Hz , /4" 3/8" KMHS V208V, 1 PH, 60 Hz ,900 14, ** This is maximum elevation difference when the indoor unit is located above the outdoor unit. (Refer to the table on the back of the catalogue) KMS , /4" 1/2" KMHS ,500 20, KMS , /4" 5/8" KMHS ,200 29, "7/32" x 32"15/32" x 7"7/16" 11"23/32" x 41"15/16" x 8"19/32" / 31 /28 / / 31 /28 / 23 1/4" 3/8" / 33 / 29 / / 31 / 29 / 25 1/4" 3/8" / 38 / 34 / / 37 / 34 / 28 1/4" 1/2" / 41 / 38 / / 40 / 37 / 30 1/4" 5/8" compressor parts R410 REFRIGERNT Inverter

13 FlexiMulti System s Connectable from 2 to 3 s Up to 3 Rooms CM1972 / CLM1972 CMH1972 Model No. CM1972 / CLM1972 CMH1972 Performance Capacity Btu/h ir Circulation High CFM Number of Connectable s SEER HSPF Electrical Rating Power Supply V, Phase, Hz Running mpere Power Input W Maximum Fuse Size mps Features Controls Fan Speeds Compressor Refrigerant / mount Charged at Shipment 1b Refrigerant Control Operation Sound Hi db Refrigerant Tubing Connections Max. llowable Tubing Length Ft Refrigerant Narrow Tube inch Tube Diameter Wide Tube inch Dimensions & Weight Unit Dimensions H x W x D inch Net Weight Lbs 19,700 1,707 2 ~ V / 208V, 1Ph, 60Hz 7.0 / 7.7 1,570 / 1, uto (Hi, Me, Lo) DC Inverter R410 / (per Unit) 150 (per System) 1/4" x 3 3/8 x 3 291/8 x 357/16 x 1219/ ,100 24,800 1,707 2 ~ V / 208V, 1Ph, 60Hz ,500 1, uto (Hi, Me, Lo) DC Inverter R410 / (per Unit) 150 (per System) 1/4" x 3 3/8 x 3 291/8 x 357/16 x 1219/ IMPORTNT It is not possible to connect an outdoor unit to only a single indoor unit. If operated with only ONE indoor unit installed, the returning refrigerant to the compressor may cause a malfunction. compressor parts R410 REFRIGERNT Inverter 13

14 FlexiMulti System s Connectable from 2 to 3 s Up to 3 Rooms CM2472 / CLM2472 CMH2472 Model No. CM2472 / CLM2472 CMH2472 Performance Capacity Btu/h ir Circulation High CFM Number of Connectable s SEER HSPF Electrical Rating Power Supply V, Phase, Hz Running mpere Power Input W Maximum Fuse Size mps Features Controls Fan Speeds Compressor Refrigerant/mount Charged at Shipment g Refrigerant Control Operation Sound Hi db Refrigerant Tubing Connections Max. llowable Tubing Length Ft Refrigerant Narrow Tube inch Tube Diameter Wide Tube inch Dimensions & Weight Unit Dimensions H x W x D inch Net Weight Lbs 25,400 1,707 2 ~ V / 208V, 1Ph, 60Hz 11.3 / ,560 / 2, uto (Hi, Me, Lo) DC Inverter R410 / (per Unit) 200 (per System with additional Refrigerant) 1/4" x 4 3/8" x 3 + 1/2" x 1 291/8 x 357/16 x 1219/ ,200 29,200 1,707 2 ~ V / 208V, 1Ph, 60Hz 9.0 / / ,040 / 2,040 2,270 / 2, uto (Hi, Me, Lo) DC Inverter R410 / (per Unit) 200 (per System with additional Refrigerant) 1/4" x 4 3/8" x 3 + 1/2" x 1 291/8 x 357/16 x 1219/ IMPORTNT It is not possible to connect an outdoor unit to only a single indoor unit. If operated with only ONE indoor unit installed, the returning refrigerant to the compressor may cause a malfunction. compressor R Inverter REFRIGERNT parts

15 FlexiMulti System s Connectable from 2 to 4 s Up to 4 Rooms CM3172 / CLM3172 CMH3172 Model No. CM3172 / CLM3172 CMH3172 Performance Capacity Btu/h ir Circulation High m 3 /h Number of Connectable s SEER HSPF Electrical Rating Power Supply V, Phase, Hz Running mpere Power Input W Maximum Fuse Size mps Features Controls Fan Speeds Compressor Refrigerant/mount Charged at Shipment g Refrigerant Control Operation Sound Hi db Refrigerant Tubing Connections Max. llowable Tubing Length Ft Refrigerant Narrow Tube inch Tube Diameter Wide Tube inch Dimensions & Weight Unit Dimensions H x W x D inch Net Weight Lbs 30,600 1,942 2 ~ V / 208V, 1Ph, 60Hz 12.3 / ,800 / 2, uto (Hi, Me, Lo) DC Inverter R410 / (per Unit) 230 (per System with additional Refrigerant) 1/4" x 4 3/8" x 2 + 1/2" x 2 351/32" x 357/16" x 1219/32" ,600 /28,600 32, ~ V / 208V, 1Ph, 60Hz 12.3 / / ,800 / 2,800 2,350 / 2, uto (Hi, Me, Lo) DC Inverter R410 / (per Unit) 230 (per System with additional Refrigerant) 1/4" x 4 3/8" x 2 + 1/2" x 2 351/32" x 357/16" x 1219/32" IMPORTNT It is not possible to connect an outdoor unit to only a single indoor unit. If operated with only ONE indoor unit installed, the returning refrigerant to the compressor may cause a malfunction. compressor R410 REFRIGERNT Inverter 15 parts

16 FlexiMulti Combination Tables CMH1972/CM1972/CLM1972 Room Total Room Total B C Capacity B C Performance Dual Zone = % % 15, % = % % 16, % = % % 17, % = % % 17, % = % % 17, % = % % 18, % Tri Zone = % % % 18, % = % % % 18, % CMH2472/CM2472/CLM2472 Room Total Room Total B C Capacity B C Performance Dual Zone = % % % = % % % = % % % = % % % = % % % = % % % = % % % = % % % = % % % Tri Zone = % % % % = % % % % = % % % % = % % % % = % % % % = % % % % CMH3172/CM3172/CLM3172 Room Total Room Total B C D Capacity B C D Performance Dual Zone = % % % = % % % = % % % = % % % = % % % = % % % = % % % = % % % = % % % = % % % = % % % = % % % = % % % Tri Zone = % % % % = % % % % = % % % % = % % % % = % % % % = % % % % = % % % % = % % % % = % % % % = % % % % = % % % % = % % % % = % % % % = % % % % Quad Zone = % % % % % = % % % % % = % % % % % = % % % % % = % % % % % = % % % % % = % % % % % = % % % % % 16

17 FlexiMulti Combination Tables CMH1972 Room Total Room Total B C Capacity B C Performance Dual Zone = % % 17, % = % % 20, % = % % 22, % = % % 23, % = % % 23, % = % % 23, % Tri Zone = % % % 23, % = % % % 23, % CMH2472 Room Total Room Total B C Capacity B C Performance Dual Zone = % % 17, % = % % 20, % = % % 22, % = % % 28, % = % % 24, % = % % 25, % = % % 28, % = % % 27, % = % % 29, % Tri Zone = % % % 25, % = % % % 27, % = % % % 28, % = % % % 28, % = % % % 29, % = % % % 29, % CMH3172 Room Total Room Total B C D Capacity B C D Performance Dual Zone = % % 17, % = % % 20, % = % % 22, % = % % 29, % = % % 30, % = % % 24, % = % % 25, % = % % 29, % = % % 30, % = % % 27, % = % % 29, % = % % 31, % = % % 30, % Tri Zone = % % % 25, % = % % % 29, % = % % % 29, % = % % % 30, % = % % % 29, % = % % % 29, % = % % % 30, % = % % % 30, % = % % % 31, % = % % % 30, % = % % % 30, % = % % % 31, % = % % % 30, % = % % % 31, % Quad Zone = % % % % 29, % = % % % % 30, % = % % % % 30, % = % % % % 30, % = % % % % 31, % = % % % % 31, % = % % % % 31, % = % % % % 32, % 17

18 CeilingSuspended ir Conditioners &Heat Pumps Wired Remote Controller (RCSTM80BG) (Included) 26TW72R / 26THW72R THW2672R Wired Remote Controller (RCSTM80BG) (Included) THW3672R 36TW72R / 42TW72R THW4272R 36THW72R / 42THW72R C2672R CH2672R C3672R CH3672R C4272R CH4272R Wired Remote Controller (RCSTM80BG) (Included) Wired Remote Controller (RCSTM80BG) (Included) 26THHW72R THHW2672R 36THHW72R THHW3672R CH3672R CH2672R Quiet Operation The ceilingmounted unit is equipped with a highly efficient, multiblade centrifugal fan that generates a powerful yet gentle airflow throughout the room. redesigned aerodynamically tested louver structure minimizes operational sound even at high fan speed. Improved Serviceability / Easy Installation External suspension method. Installation time can be shortened. Improved accessibility to electronic components (control box) for serving. 18 compressor parts R410 REFRIGERNT Inverter

19 CeilingSuspended ir Conditioners &Heat Pumps uto Louver Function Provides Optimum irflow During or Operation uto louver function is a standard feature which provide optimum airflow during heating or cooling operation. ngle of louver is automatically set for heating or cooling. For example, when heating with fan speed set to low, the discharge is aimed downward so that warm air reaches the floor. The louver angle can be set to between 4 above and 80 below the horizontal in five steps. n auto sweep function to distribute the airflow over a wide area is also provided. Wind direction is adjusted automatically in both heating and cooling operation. The louver can also be set to swing automatically from F1 to F5 in any operation mode (heat pump type only). Fresh ir Intake Capability & Duct Extension F1 F2 60 F3 F4 F5 Ceiling Recessed models (Xseries), Ceiling Suspended models (Tseries) have the capability of bringing fresh air from outside using an air intake duct (field supplied). (Xseries require optional Fresh ir intake plenum) Using ir intake plenum, it is possible to connect an air duct extension (field supplied) to Ceiling Recessed models (Xseries) to improve the room air circulation. F1 F5 F1 F3 Model No. Unit Model No. Performance & Electrical Ratings Capacity Btu/h Btu/h Moisture Removal High Pints/H Dry ir Flow Hi / Med / Low CFM SEER HSPF C Power Supply V, Phase, Hz Running mps Power Input W W Backup Heater kw Fuse or Circuit Breaker Capacity Features Controls Low mbient Control (for ) Wireless (optional) Wired (included) Fan Speeds Timer Ceiling Suspended ir Conditioners 26TW72R THW2672R C2672R 24,400 (9,500~24,400) / 490 / / ,880 / 2, Builtin 0 F (RCSSH80UWL, RCSBH80UWL) RCSTM80BG 3 and Control / Variable 36TW72R THW3672R C3672R 31,200 (9,500~31,200) / 930 / / ,840 / 3, Builtin 0 F (RCSSH80UWL, RCSBH80UWL) RCSTM80BG 3 and Control / Variable Ceiling Suspended Heat Pumps w/ Heater 42TW72R THW4272R C4272R 39,000 (9,500~39,000) / 950 / / ,140 / 4, Builtin 0 F (RCSSH80UWL, RCSBH80UWL) RCSTM80BG 3 and Control / Variable 26THHW72R THHW2672R CH2672R 24,400 (9,500~24,400) 30,800 (8,000~30,800) / 490 / / / ,880 / 2,880 3,000 / 3, / Builtin 0 F RCSSH80UWL / RCSBH80UWL) RCSTM80BG 3 and Control / Variable 36THHW72R THHW3672R CH3672R 31,200 (9,500~31,200) 37,400 (8,000~37,400) / 930 / / / ,840 / 3,840 3,250 / 3, / Builtin 0 F (RCSSH80UWL, RCSBH80UWL) RCSTM80BG 3 and Control / Variable ir Deflection Horizontal Vertical ir Filter Refrigerant R410 R410 R410 R410 Refrigerant control Operation Sound In (Hi / Me / Lo)dB 39 / 37 / / 40 / / 41 / 3 39 / 37 / 33 Outdoor(Hi) db Refrigerant Piping Type Discharge Suction Refrigerant Pipe Length Ft. Elevation Difference** Outdoor bove Ft. Outdoor Below Ft. Dimensions & Weight Height 717/32" 3023/32" 97/16" 3023/32" 97/16" 487/16" 717/32" 3023/32" Width 513/16" 37" 621/32" 37" 621/32" 37" 513/16" 37" Depth 263/8" 133/8" 263/8" 33/8" 263/8" 133/8" 263/8" 133/8" Net Weight Lbs ** This is maximum elevation difference when the indoor unit is located above the outdoor unit. (Refer to the table on the back of the catalogue) R / 40 / /16" 3023/32" 621/32" 37" 263/8" 133/8" Ceiling Suspended Heat Pumps 26THW72R THW2672R CH2672R 24,400 (9,500~24,400) 30,800 (8,000~30,800) / 490 / / / ,880 / 2,880 3,000 / 3, Builtin 0 F (RCSSH80UWL, RCSBH80UWL) RCSTM80BG 3 and Control / Variable R / 37 / /32" 3023/32" 513/16" 37" 263/8" 133/8" THW72R THW3672R CH3672R 31,200 (9,500~31,200) 37,400 (8,000~37,400) / 930 / / / ,840 / 3,840 3,250 / 3, Builtin 0 F (RCSSH80UWL, RCSBH80UWL) RCSTM80BG 3 and Control / Variable R / 40 / /16" 3023/32" 621/32" 37" 263/8" 133/8" THW72R THW4272R CH4272R 39,000 (9,500~39,000) 44,500 (8,000~44,500) / 950 / / / ,140 / 4,140 3,630 / 3, Builtin 0 F (RCSSH80UWL, RCSBH80UWL) RCSTM80BG 3 and Control / Variable R / 41 / /16" 487/16" 621/32" 37" 263/8" 133/8" compressor parts R410 REFRIGERNT Inverter 19

20 CeilingRecessed ir Conditioners &Heat Pumps XHW2672R XHW3672R C2672R C3672R Wired Remote Controller (RCSTM80BG) (Included) 26XW72R 36XW72R Grille ssembly PNRXH2442 PNRXH3642 XHW4272R Grille ssembly PNRXH3642 C4272R 42XW72R Wired Remote Controller (RCSTM80BG) (Included) Wired Remote Controller (RCSTM80BG) (Included) 26XHW72R 36XHW72R XHW2672R XHW3672R Grille ssembly PNRXH2442 PNRXH3642 CH2672R CH3672R XHW4272R Grille ssembly PNRXH3642 CH4272R 42XHW72R Wired Remote Controller (RCSTM80BG) (Included) 20

21 CeilingRecessed ir Conditioners &Heat Pumps 4Way irflow Design Sends Cool ir in all Directions ir is returned through the center of the grille, while evenly distributing air through each of the 4 supply air openings. Installation in the center of the room provides for the greatest comfort. However, 1 or 2 supply louvers can be closed for installation near 1 wall to provide 3 or 2 way airflow. lso, by closing off 1 supply louver, you may attach a duct (field supply) to the upper plenum and provide conditioned air to another, separate area. 4Way Discharge 3Way Discharge 2Way Discharge WhisperQuiet Operation Thanks to the newly developed turbo fan and decreased resistance of the air path, one of the industry s lowest levels of noise has been achieved. Integrated Drain Pump Fresh ir Intake Plenum (Option) Drain pump is built into the unit to raise the condensate up 20 from the drain pump discharge. Motor Casing Rotating blade Suction Flow of drain water Drain water When used to take in fresh air, attach the fresh airintake plenum to the unit. irintake plenum is optionally supplied. CMBGSJ80U for XHW2672R CMBGSJ140U for XHW3672R, XHW4272R Model No. Unit Model No. Grille ssembly Performance & Electrical Ratings Capacity Btu/h Btu/h Moisture Removal High Pints/H Dry ir Flow Hi / Med / Low CFM SEER HSPF C Power Supply V, Phase, Hz Running mps Power Input W W Backup Heater kw Fuse or Circuit Breaker Capacity Features Controls Low mbient Control (for ) Wireless (optional) Wired (included) Fan Speeds Timer Ceiling Recessed ir Conditioners 26XW72R XHW2672R C2672R PNRXH ,800 (9,500 ~ 24,800) / 530 / / ,920 / 2, Builtin 0 F RCSSH80UWL, RCSBH80UWL RCSTM80BG 3 and Control / Variable 36XW72R XHW3672R C3672R PNRXH ,600 (9,500 ~ 32,600) / 840 / / ,950 / 3, Builtin 0 F RCSSH80UWL, RCSBH80UWL RCSTM80BG 3 and Control / Variable 42XW72R XHW4272R C4272R PNRXH ,500 (9,500 ~ 39,500) / 840 / / ,520 / 4, Builtin 0 F RCSSH80UWL, RCSBH80UWL RCSTM80BG 3 and Control / Variable 26XHW72R XHW2672R CH2672R PNRXH ,800 (9,500 ~ 24,800) 29,800 (8,000 ~ 29,800) / 530 / / / ,920 / 2,920 2,790 / 2, Builtin 0 F RCSSH80UWL, RCSBH80UWL RCSTM80BG 3 and Control / Variable ir Deflection Horizontal Vertical ir Filter Refrigerant R410 R410 R410 R410 Refrigerant control Operation Sound In(Hi / Me / Lo) db 38 / 35 / / 37 / / 38 / / 35 / 31 Outdoor(Hi) db Refrigerant Piping Type Discharge Suction Refrigerant Pipe Length Ft. Elevation Difference** Outdoor bove Ft. Outdoor Below Ft. Dimensions & Weight Height 135/16" 3023/32" 1431/64" 3023/32" 1431/64" 487/16" 135/16" 3023/32" Width 3355/64" 37" 459/32" 37" 459/32" 37" 3355/64" 37" Depth 3355/64" 133/8" 3355/64" 133/8" 3355/64" 133/8" 3355/64" 133/8" Net Weight Lbs ** This is maximum elevation difference when the indoor unit is located above the outdoor unit. (Refer to the table on the back of the catalogue for more detail.) CeilingRecessed H/P 36XHW72R XHW3672R CH3672R PNRXH ,600 (9,500 ~ 32,600) 37,600 (8,000 ~ 37,600) / 840 / / / ,950 / 3,950 3,350 / 3, Builtin 0 F RCSSH80UWL, RCSBH80UWL RCSTM80BG 3 and Control / Variable R / 37 / /64" 3023/32" 459/32" 37" 3355/64" 133/8" XHW72R XHW4272R CH4272R PNRXH ,500 (9,500 ~ 39,500) 48,000 (8,000 ~ 48,000) / 840 / / / ,520 / 4,520 4,360 / 4, Builtin 0 F RCSSH80UWL, RCSBH80U. WL RCSTM80BG 3 and Control / Variable R / 38 / /64" 487/16" 459/32" 37" 3355/64" 133/8"

22 Concealed Duct ir Conditioners &Heat Pumps BuiltIn Drain Pump Wired Remote Controller (RCSTM80BG) (Included) Drain pump is built into the unit to raise the condensate up 20 from the drain pump discharge. 26UW72R / 26UHW72R UHW2672R Supplies are 8 dia Installation Example C2672R CH2672R bove picture shows the standard ducting system, where air is taken in from the back of the unit. This system is useful for places which need extensive air conditioning, including conference halls, showrooms, and restaurants. Wired Remote Controller (RCSTM80BG) (Included) 36UW72R / 36UHW72R UHW3672R Supplies are 8 dia C3672R CH3672R Outline diagram with medium or highperformance filter field installed. Concealed Duct ir Conditioners Concealed Duct Heat Pumps Model No. 26UW72R 36UW72R 26UHW72R 36UHW72R Unit Model No. UHW2672R C2672R UHW3672R C3672R UHW2672R CH2672R UHW3672R CH3672R Performance & Electrical Ratings Btu/h 24,000 (9,500 ~ 24,000) 31,200 (9,500 ~ 31,200) 24,000 (9,500 ~ 24,000) 31,200 (9,500 ~ 31,200) Capacity Btu/h 28,600 (8,000 ~ 28,600) 36,200 (8,000 ~ 36,200) Moisture Removal High Pints/H Dry ir Flow Hi / Med / Low CFM 670 / 530 / / 920 / / 530 / / 920 / 750 External Static Pressure in. q SEER EER HSPF C Power Supply V, Phase, Hz Running mps 13.6 / / / / / / 17.6 Power Input W 2,600 / 2,600 3,920 / 3,920 2,600 / 2,600 3,920 / 3,920 W 2,400 / 2,400 3,340 / 3,340 External Static Pressure in. WC Fuse or Circuit Breaker Capacity Features Controls Low mbient Control Wireless (optional) Wired (included) Builtin 0 F RCSBH80UWL RCSTM80BG Builtin 0 F RCSBH80UWL RCSTM80BG Builtin 0 F RCSBH80UWL RCSTM80BG Builtin 0 F RCSBH80UWL RCSTM80BG Fan Speeds 3 and Control / Variable 3 and Control / Variable 3 and Control / Variable 3 and Control / Variable Timer ir Deflection Horizontal Vertical ir Filter Refrigerant Refrigerant control Operation Sound In(Hi / Me / Lo) db 34 / 30 / / 33 / 31 Outdoor(Hi) db Refrigerant Piping Type Discharge Suction Refrigerant Pipe Length Ft. Elevation Difference** Outdoor bove Ft. Outdoor Below Ft. Dimensions & Weight Height 127/32" 3023/32" 127/32" 3023/32" Width 393/8" 37" 589/32" 37" Depth 2413/16" 133/8" 2413/16" 133/8" Net Weight Lbs pprovals ** This is maximum elevation difference when the indoor unit is located above the outdoor unit. (Refer to the table on the back of the catalogue for more detail.) 34 / 30 / /32" 3023/32" 393/8" 37" 2413/16" 133/8" / 33 / /32" 3023/32" 589/32" 37" 2413/16" 133/8"

23 Optional ccessories H.V..C. ccessories MODEL NO. DESCRIPTION USE WITH P0905BH Insulated Tubing Kit 1/4" and 3/8" x 15' 09KS71, 09KLS71, 09KHS71, 12KS71, 12KLS71, 12KHS71 KMHS0772, KMHS0972, KMHS1272, KMS0772, KMS0972, KMS1272 P0907BH Insulated Tubing Kit 1/4" and 3/8" x 20' CM1972 (2), CM2472 (2), CM3172 (2) CMH1972 (2), CMH2472 (2), CMH3172 (2) PO910BH Insulated Tubing Kit CLM1972 (2), CLM2472 (2), CLM3172 (2) 1/4" and 3/8" x 35' P1205BH Insulated Tubing Kit 1/4" and 1/2" x 15' 18KS72, 18KLS72, 18KHS72 KMHS1872, KMS1872, P1207BH Insulated Tubing Kit 1/4" and 1/2" x 20' CM1972 (1), CMH1972 (1), CLM1972 (1) CM2472 (1), CMH2472 (1), CLM2472 (1) P1210BH Insulated Tubing Kit CM3172 (1), CMH3172 (1), CLM3172 (1) 1/4 and 1/2" x 35' P2507BH Insulated Tubing Kit 1/4" and 5/8" x 20' 24KS72, 24KLS72, 24KHS72 KMHS2472, KMS2472 P2510BH Insulated Tubing Kit 1/4" and 5/8" x 30' CM2472 (1), CMH2472 (1), CLM2472 (1) CM3172 (1), CMH3172 (1), CLM3172 (1) P2515BH Insulated Tubing Kit 1/4" and 5/8" x 50' P3010BH Insulated Tubing Kit 3/8" and 5/8" x 30' 26KS/KHS/KHHS72R, 30KS/KHS72R, 36KS/KHS/KHHS72R 26XW/XHW72R, 36XW/XHW72R,42XW/XHW72R P3015BH Insulated Tubing Kit 26TW/THW/THHW72R, 36TW/THW/THHW72, 42TW/THW72R 3/8" and 5/8" x 50' CMBGSJ80U Fresh ir Intake Plenum XH/XHW2672R CMBGSJ140U Fresh ir Intake Plenum XH/XHW3672R,XH/XHW4272R Display Stand Display Stand 09KS71, 09KLS71, 09KHS71 KKS0971 Indoor Display Shell KS0971 Display Shell KC0970 Outdoor Display Shell C0971 Display Shell RCS5PS4B Locking Bracket for RCSSH1U,RCSSH80UWL,RCSBH80UWL RCS4MHVB Locking Bracket for KS0971,KS1271,KS1872,KS2472,KHS0971,KHS1271,KHS1872,KHS2472 KM[H]S0772,KM[H]S0972,KM[H]S1272,KM[H]S1872,KM[H]S2472 STKKSB2050 Mounting Bracket for 09KS71, 09KLS71, 09KHS71, 12KS71, 12KLS71, 12KHS71 STKKSB5050 Mounting Bracket for 18KS72,18KLS72,18KHS72,24KS72,24KLS72,24KHS72 CM1972, CM2472, CM3172, CLM1972, CLM2472, CLM3172 CMH1972, CMH2472, CMH3172 SI31001 Condensate Pump ll 115 volt Models SI31002 Condensate Pump ll 230 volt Models (up to 2ton) SI17302 Condensate Pump ll 230 volt Models(High Vol. Condensate Removal) (2ton and higher) RCSKR1GB Simple Remote ll 26,000 Through 42,000 BTU/h Models Controller RCSTM80BG Wired Timer/ ll 26,000 Through 42,000 BTU/h Models RCSSH1U Wireless Remote KH2672R,KH3072R,KH3672R Controller RCSSH80UWL Wireless Remote Controller TH/THH/THW/THHW2672R, TH/THH/THW/THHW3672R,TH/THW4272R, XH/XHW2672R,XH/XHW3672R,XH/XHW4272R RCSBH80UWL Wireless Remote UH/UHW2672R,UH/UHW3672R Controller SHKC64UG System Controller ll 26,000 Through 42,000 BTU/h Models STKFDXB patite Filter KS0971,KS1271,KS1872,KS2472,KHS0971,KHS1271,KHS1872,KHS2472 KMS0772,KMS0972,KMS1272,KMS1872,KMS2472 KMHS0772,KMHS0972,KMHS1272,KMHS1872,KMHS2472 WINDB1 Wind Baffle ll C, CL and CH Models Refrigerant Line Set P0905BH P2507BH P0907BH P2510BH P0910BH P2515BH P1205BH P3010BH P1207BH P3015BH Fresh ir Intake Plenum CMBGSJ80U CMBGSJ140U patite Filter STKFDXB Locking Bracket for Remote Control RCS5PS4B RCS4MHVB Condensate Drain Pump SI31001 SI31002 SI17302 System Controller SHKC64UG Wireless Remote RCSBH80UWL Mounting Bracket STKKSB2050 STKKSB5050 Timer RCSTM80BG Wireless Remote RCSSH80UWL 23

SANYO Air Conditioners & Heat Pumps

SANYO Air Conditioners & Heat Pumps ir Conditioning & Heat Pump Products Revised May 10 SNYO ir Conditioners & Heat Pumps Btu/h 9,000 12,000 18,000 24,000 26,000 30,000 36,000 42,000 Type Standard Low mbient Standard Low mbient Standard

More information

Air Conditioning & Heat Pump Products

Air Conditioning & Heat Pump Products Air Conditioning & Heat Pump Products Preliminary Revised April 06 SANYO Air Conditioners & Heat Pumps Btu/h 9,000 12,000 18,000 24,000 26,000 30,000 36,000 42,000 Type Standard Low Ambient Standard Low

More information

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History

More information

AIR CONDITIONING and HEAT PUMP PRODUCTS

AIR CONDITIONING and HEAT PUMP PRODUCTS AIR CONDITIONING and HEAT PUMP PRODUCTS February 2015 The History of Panasonic Air Conditioning The Panasonic Air Conditioning Group has grown into a global company through its continuous quest for product

More information

york air-conditioning products Residential & VRF News 2015

york air-conditioning products Residential & VRF News 2015 york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter

More information

FTXS. Wall Mount Heat Pump or Cooling Only

FTXS. Wall Mount Heat Pump or Cooling Only FTXS Wall Mount Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FTXS SkyAir systems feature streamlined, wall mounted indoor units paired with quietly compact outdoor units. Available in both

More information

AIR CONDITIONING & HEAT PUMP PRODUCTS

AIR CONDITIONING & HEAT PUMP PRODUCTS AIR CONDITIONING & HEAT PUMP PRODUCTS JANUARY 2012 (ver.1.0) New Panasonic Group New Panasonic Group Contributing to the progress and development of society and enriching people s lives through manufacturing

More information

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS AN EXCELLENT CHOICE IN COOLING, COMFORT AND CONVENIENCE Why choose a Mini-Split system? Installing

More information

ECO-AIR AIR CONDITIONING www.northamericanhvac.com

ECO-AIR AIR CONDITIONING www.northamericanhvac.com INDEX ACCESSORIES INSTALLATION... 3-7 LINE SETS... 3-7 GEOTHERMAL... 3-8 WIRING CABLE... 3-8 CIRCULATOR PUMPS (PRO-TECH MODEL)... 3-9 DC INVERTER SINGLE ZONE HEAT PUMP... 3-6 DC INVERTER TECHNOLOGY...

More information

AIR CONDITIONING and HEAT PUMP PRODUCTS

AIR CONDITIONING and HEAT PUMP PRODUCTS Model Identification RAC Set C S S 3 4 8 N K 5 6 7 U 8 9 C U S 3 4 8 N K 5 6 7 U 8 9 S 3 4 8 N K 5 6 7 U 8 9 Series ModelType 3 Connection configuration 4 Function 5 Capacity 6 Development 7 Category Type

More information

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT

More information

Inverter Air Conditioning for Light Commercial Use

Inverter Air Conditioning for Light Commercial Use Inverter Air Conditioning for Light Commercial Use 02 Cost Saving Comfort An efficient use of time 03 SDISuper Digital Inverter Very efficient energy consumption Keeps down operating costs Heater operation

More information

PRODUCT CATALOG. Indoor Units

PRODUCT CATALOG. Indoor Units PRODUCT CATALOG Indoor Units Life s Good! From installation to maintenance, LG runs more than 60 global air conditioning academies, each provides training for air conditioning professionals. What is LG?

More information

REMOTE CONTROL MANUAL

REMOTE CONTROL MANUAL REMOTE CONTROL MANUAL ENGLISH CONTENT PRECAUTIONS...1-2 USING THE REMOTE CONTROL UNIT...3 OPERATION...4-9 Thank you for purchasing our Room Air Conditioner. Before using your air-conditioner, please read

More information

DUCTED AIR CONDITIONING SOLUTIONS

DUCTED AIR CONDITIONING SOLUTIONS DUCTED AIR CONDITIONING SOLUTIONS H I G H E N E R G Y E F F I C I E N C Y B A C K E D B Y A 5 Y E A R F U L L P A R T S & L A B O U R W A R R A N T Y DUCTED RANGE WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump R-410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H)-System, DFC4(A/H)3-Outdoor, DFF4(A/H)H-Indoor Please read the operating instructions and safety precautions carefully

More information

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM 13 5. EXPLOSION VIEW 16 6

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM 13 5. EXPLOSION VIEW 16 6 TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE080528 Models KFTHP-12 KFTHP-18 KFTHP-24 CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL

More information

Ductless Systemss A COMFORTABLE, CONVENIENT SOLUTION BUILT TO A HIGHER STANDARD. READ ONLY

Ductless Systemss A COMFORTABLE, CONVENIENT SOLUTION BUILT TO A HIGHER STANDARD. READ ONLY Ductless Systemss A COMFORTABLE, CONVENIENT SOLUTION BUILT TO A HIGHER STANDARD. READ ONLY Designed and built with the commitment to high-quality craftsmanship you expect from American Standard, our ductless

More information

Air Conditioning & Heat Pump Products Technical Training

Air Conditioning & Heat Pump Products Technical Training Air Conditioning & Heat Pump Products Technical Training Single Mini Split 9,000-24,000 Btu Flexi-Multi 19,000-31,000 Btu Single Mini Split 26,000-42,000 Btu Table of contents Page 1) Dealer training &

More information

innovative comfort solutions

innovative comfort solutions engineering and specifications Guide duct-free air conditioning systems Art cool inverter flex multi-split floor standing ceiling cassette PTAC PTHP through-the-wall innovative comfort solutions 1 AT LG,

More information

Residential and Light Commercial Air Conditioning Systems

Residential and Light Commercial Air Conditioning Systems Residential and Light Commercial Air Conditioning Systems Beautifully Designed to Save Engineering and Specifications Guide Beautifully Designed to Save As air conditioners have reached high levels of

More information

2010 Duct-Free Splits Line Card

2010 Duct-Free Splits Line Card 2010 Duct-Free Splits Line Card Right Product for the Right Application 2010 Duct-Free Splits Right Product for the Right Application 1:1 2:1 to 4:1 9-24K High Walls 18-24/36/42/60K High Wall, Cassette,

More information

FTQ. Daikin Inverter Ducted Heat Pump

FTQ. Daikin Inverter Ducted Heat Pump FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative

More information

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3

More information

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER

More information

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner

More information

FHQ. Ceiling Suspended Heat Pump or Cooling Only

FHQ. Ceiling Suspended Heat Pump or Cooling Only FHQ Ceiling Suspended Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FHQ ceiling suspended SkyAir systems are ideal for applications without false ceilings. Installed from the structure, this

More information

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy LG Air conditioning Company Multi V Water Ⅱ Air Conditioning Academy 1.1 What is Multi V Water II? High Performance Prospect rights Water pipe Refrigerant pipe Indoor unit Beautiful Exterior Convenience

More information

Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort

Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort Heat Pump Product Brochure 2015/2016 Premier Series Hi-Wall Split Systems Everyday Comfort Everyday Innovation We design with you in mind. You ll find that Haier Heat Pump units are quiet, efficient and

More information

Submitted to Reference Approval Construction Unit Designation Schedule #

Submitted to Reference Approval Construction Unit Designation Schedule # SUBMITTAL AQV09JA High Wall 9,000 Btu/h Heat Pump Nom Cooling Capacity (Btu/h) 9,000 SEER 20.0 Cool Capacity Range (Btu/h) 3,100 to 11,900 Nom Heating Capacity (Btu/h) 11,950 HSPF 10.0 Heating COP 3.7

More information

SiBE12-625. D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump

SiBE12-625. D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump SiBE12-625 D-Series / E-Series [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump SUPER MULTI NX D-Series / E-Series Cooling Only Indoor Unit FTKS20D3VMW FTKS20CAVMB FDKS25CAVMB

More information

Contents. Part 1 General Information... 1. Part 2 Outdoor Units... 9. Part 3 Installation... 50. Part 4 Troubleshooting 73

Contents. Part 1 General Information... 1. Part 2 Outdoor Units... 9. Part 3 Installation... 50. Part 4 Troubleshooting 73 MCAC-VTSM-2013-03 R410a Full DC Inverter Mini VRF Contents Part 1 General Information... 1 Part 2 Outdoor Units... 9 Part 3 Installation... 50 Part 4 Troubleshooting 73 Part 5 Control System... 100 Manufacture

More information

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled

More information

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Gree Solar Hybrid Hi Wall Inverter Air Conditioner Gree Solar Hybrid Hi Wall Inverter Air Conditioner Utilize the natural power of the sun to heat or cool your home. Find out more at www.greeonline.com Why Choose a Solar Hybrid Inverter? The new Gree Solar

More information

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS. T H R U - T H E - W A L L A I R C O N D I T I O N E R S 26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS. W A L L M A S T E R T H R U - T H E - W A L L A I R C O N D I T I O N E R

More information

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications

More information

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

Ductless Mini-Split Systems. Comfort... where you need it, when you need it Ductless Mini-Split Systems Comfort... where you need it, when you need it Ductless mini-splits THE COMFORT SOLUTION Ductless mini-split systems are a great solution to a wide variety of installation challenges,

More information

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

SINGLE PACKAGE VERTICAL AIR CONDITIONERS SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,

More information

LG Duct-Free Split Systems Product Overview. LG comfort solutions that you never thought possible

LG Duct-Free Split Systems Product Overview. LG comfort solutions that you never thought possible LG Duct-Free Split Systems Product Overview LG comfort solutions that you never thought possible TABLE OF CONTENTS Company Introduction Introduction 4 Duct Free System Introduction 6 Key Features 8 Duct-Free

More information

More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A

More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A More than Air Conditioning Catalogue 2004/2005 Air Conditioning Program R 407C R 410A MITSUBISHI ELECTRIC Air Conditioning Systems As one of the world s leading technology companies, MITSUBISHI ELECTRIC

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LECA AS G09LECA AS G12LECA AS G14LECA OUTDOOR AO G07LEC AO G09LEC AO G12LEC AO G14LEC 1. INDOOR UNIT : AS G07LECA AS G09LECA AS

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL INDOOR UNIT : CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU CS-MKE18NKU CS-MKE24NKU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 7,500BTU / h 9,000BTU

More information

Instruction manual for Firstline FCS12000CH

Instruction manual for Firstline FCS12000CH Instruction manual for Firstline FCS12000CH Contents Introduction... 2 Safety Awareness... 3 Safety Awareness... 4 Name of Parts... 5 Name of Parts... 6 Remote Controller Preparation... 7 Operation of

More information

OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex

OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex Version C Single, Dual, Tri or Quad Zone Ductless Mini-Split System Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com

More information

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA USER S MANUAL FH052EAV1 FH070EAV1 E HNIKA PORTUGUÊS ENGLISH ESPAÑOL ITALIANO DEUTSCH FRANÇAIS System Air Conditioner (Cooling and Heating) E S F I P D G DB98-29263A(1) Safety Precautions Register your

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer

More information

FBQ. DC Duct Heat Pump or Cooling Only

FBQ. DC Duct Heat Pump or Cooling Only FBQ DC Duct Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FBQ DC Duct systems offer a powerful solution, compact in design and easily concealed in a ceiling. With both cooling only and heat

More information

DUCT TYPE AIR CONDITIONER

DUCT TYPE AIR CONDITIONER OPERATING MANUAL OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE INSTRUÇÕES AIR CONDITIONER DUCT TYPE English Deutsch

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF ASU5RLS AOU 9RLFW AOURLFW AOU5RLS R40A CONTENTS. DESCRIPTION OF EACH CONTROL

More information

Ductless Heat Pumps. Gary Nordeen January 2009. www.nwbuildings.org/dhp.aspx info@nwbuildings.org

Ductless Heat Pumps. Gary Nordeen January 2009. www.nwbuildings.org/dhp.aspx info@nwbuildings.org Ductless Heat Pumps Gary Nordeen January 2009 www.nwbuildings.org/dhp.aspx info@nwbuildings.org Outline Heat Pump Basics Ductless Heat Pumps Efficiency Advantages Commercial installations Planning (applications,

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL CSKS12NB41 & CZ18BT1U + CUKS12NK1A CSKS18NB4UW & CZ18BT1U + CUKS18NKU CSKS18NB4UW & CZ18BT1U + CUKS18NKUA DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel)

More information

Portable Air Conditioner

Portable Air Conditioner Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE

More information

System. SERVICE MANUAL R410A MODEL : ARNU Series URNU Series

System. SERVICE MANUAL R410A MODEL : ARNU Series URNU Series Internal Use Only http://biz.lgservice.com System Indoor Unit R410A SERVICE MANUAL R410A MODEL : ARNU Series URNU Series CAUTI Before Servicing the unit, read the safety precautions in General SVC manual.

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05 TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation

More information

FULL DC INVERTER SYSTEMS

FULL DC INVERTER SYSTEMS FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation

More information

Mini-Split Air Conditioners and Heat Pumps for Residential and Light Commercial Applications

Mini-Split Air Conditioners and Heat Pumps for Residential and Light Commercial Applications Mini-Split Air Conditioners and s for Residential and Light Commercial Applications 3 TABLE OF CONTENTS FEATURES Mini-Splits Defined... 4 Individual Zoning... Comfort Solution... 8 Energy Efficient...

More information

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER + SAP C181MA + SAP C181GA + SAP C181BA + SAP C241MA + SAP C241BA FILE NO.

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER + SAP C181MA + SAP C181GA + SAP C181BA + SAP C241MA + SAP C241BA FILE NO. TECHNICAL & SERVICE MANUAL SAP K161GJA SAP K181GJA SAP K181MBA SAP K241GJA SAP K241MBA + SAP C161GA + SAP C161JA + SAP C181GA + SAP C181JA + SAP C181MA + SAP C181BA + SAP C241GA + SAP C241JA + SAP C241MA

More information

1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/

1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/ 1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/ ISO 9001 ISO 14001 Certified number : 01 100 89394 Certified number : 01 104 9245101 Fujitsu General (Thailand) Co.,

More information

Operating Instructions Split System Air Conditioner

Operating Instructions Split System Air Conditioner Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This

More information

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor

More information

How To Make A High Efficiency Thermostat

How To Make A High Efficiency Thermostat Zoning with Variable Speed Mini-Split Systems Fujitsu Service Training Welcome - Thank you for attending Did you know? In 1940 only 42% of homes in the US had central heating In 1970 20% of homes had central

More information

Glossary of Heating, Ventilation and Air Conditioning Terms

Glossary of Heating, Ventilation and Air Conditioning Terms Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment

More information

WINDOW ROOM AIR CONDITIONER

WINDOW ROOM AIR CONDITIONER WINDOW ROOM AIR CONDITIONER Installation and Operation Manual Electromechanical Remote Control CAPACITIES 220V - 60 HZ. 12,000; 18,000; 24000 BTU/HR 220V-240V - 50 HZ. 12,000; 18,000; 24000 BTU/HR Please

More information

Duct Free Split Air ConditionerS

Duct Free Split Air ConditionerS Duct Free Split Air ConditionerS Quality, convenience, efficiency, quiet operation More stylish than a room air conditioner, gives you back your window space, and quieter than conventional central air

More information

SiUS091133. Service Manual. Inverter Pair FTXS-L Series FDXS-L Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SiUS091133. Service Manual. Inverter Pair FTXS-L Series FDXS-L Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Service Manual Inverter Pair FTXS-L Series FDXS-L Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair FTXS-L Series FDXS-L Series Cooling Only Indoor Unit FTXS30LVJU

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries

More information

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg 83 84 85 85 86 88 89 90

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg 83 84 85 85 86 88 89 90 6 Air Movement Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners Pg 83 84 85 85 86 88 89 90 83 Air Movement JKI Heaters Aurora Bathroom Heater Quartz 2

More information

Residential and Light Commercial Air Conditioning Systems

Residential and Light Commercial Air Conditioning Systems Residential and Light Commercial Air Conditioning Systems Beautifully Designed to Save Engineering and Specifications Guide Beautifully Designed to Save As air conditioners have reached high levels of

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CM97 CM7 CM7 FILE NO. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 9,700 BTU/h,00 BTU/h 0,600 BTU/h Outdoor Model No. CM97

More information

LG AIR CONDITIONING SYSTEMS

LG AIR CONDITIONING SYSTEMS LG AIR CONDITIONING SYSTEMS THE NEW STANDARD IN COMFORT INNOVATIVE COMFORT SOLUTIONS AT LG, WE BELIEVE COMFORT SHOULD ALWAYS BE BEAUTIFUL. 4 Table of Contents INTRODUCTION 04-07 ART COOL 08-11 SINGLE

More information

Single Zone LCD Thermostat Operating Instructions

Single Zone LCD Thermostat Operating Instructions Fan Cool Furnace *Heat Pump or Heat Strip On/Off F Single Zone LCD Thermostat Operating Instructions MODEL 3313192.XXX Cool/Furnace 3313193.XXX Cool/Furnace/Heat Pump 3313194.XXX Cool/Furnace/Heat Strip

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0 Air Conditioner Service Manual 2 3 Model: AC-S13CG x 2 3 Content Technical specification.. 4 Performance curve.5 Outline & dimension of indoor unit..10 Outline & dimension of outdoor unit 11 Exploded view

More information

14. Troubleshooting Guide

14. Troubleshooting Guide 14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include

More information

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT UP TO 15 SEER Performance MINI-SPLIT SYSTEM UNITS AIR CONDITIONING AND HEAT PUMPS COMPLETE ROOM COMFORT WITH EASY-TO-USE REMOTE CONTROL HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT The Goodman brand offers

More information

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System For Residential & Light Commercial Applications 4 Ton 8 Zone Multi Split Heat Pump System EXPERTISE AND INNOVATION The Super Multi PLUS Split System is the ultimate, flexible solution for individual zone

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LKC AS A12LKC OUTDOOR AO R09LKC AO R12LKC 1.INDOOR UNIT : AS A09LKC AS A12LKC DTR_AS039E_01 2010.02.24 1. INDOOR UNIT CONTENTS 1.

More information

Room Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View) Internal Use Only http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MODEL : LSN092CE(ASNC0914DH0)/LSN092HE(ASNH091E1H0) LSU092CE(ASUC0914DH0)/LSU092HE(ASUH091E1H0) LSN122CE(ASNC121E1H0)/LSN122HE(ASNH121E1H0)

More information

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Hitachi Air Conditioning Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Contents Page 04 Product Range 08-09 RAC Summit Wall Mounted 10 RAC Shirokuma Wall mounted 11 RAC S Series - Wall

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL CSKE1NB41 & CZ18BT1U + CUKE1NK1 CSKE18NB4UW & CZ18BT1U + CUKE18NKU DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel) CSKE1NB41 (CZ18BT1U) CSKE18NB4UW (CZ18BT1U)

More information

System. SERVICE MANUAL R410A MODEL : ARNU Series URNU Series

System. SERVICE MANUAL R410A MODEL : ARNU Series URNU Series Internal Use Only http://biz.lgservice.com System Indoor Unit R410A SERVICE MANUAL R410A MODEL : ARNU Series URNU Series CAUTI Before Servicing the unit, read the safety precautions in General SVC manual.

More information

Samsung Room Air Conditioning

Samsung Room Air Conditioning Samsung Room Air Conditioning Air Conditioning Solutions from a Trusted Brand At the heart of family living is the home, a place full of special moments and wonderful memories where families live and

More information

SiUS041111. Service Manual. Inverter Pair Wall Mounted Type K-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SiUS041111. Service Manual. Inverter Pair Wall Mounted Type K-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type K-Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type K-Series Cooling Only Indoor Unit FTXN09KEVJU

More information

emura Form. redefined.

emura Form. redefined. emura Form. function. redefined. IT S ALL ABOUT DESIGN if award Daikin Europe N.V. is proud to announce that Daikin Emura has been awarded an if Product Design Award for 2010. For 56 years, the if product

More information

FCQ. Roundflow Cassette Heat Pump or Cooling Only

FCQ. Roundflow Cassette Heat Pump or Cooling Only FCQ Roundflow Cassette Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FCQ roundflow cassette SkyAir systems are ideal for open plan applications where variances in temperature and airflow

More information

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle KSV70HRF RRP AUS $1,709.00 Split System Reverse Cycle air conditioner featuring inverter technology, clean front with LED display, Bio and active carbon filter, 2 way auto swing (up, down), remote (7.1kW

More information

air conditioners how to choose a cooling system

air conditioners how to choose a cooling system air conditioners how to choose a cooling system taking responsibility As an individual, your efficient use of energy brings benefits such as lower bills, improved comfort levels in your home and a reduced

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

Single Package Vertical Air Conditioners. Vert-I-Pak

Single Package Vertical Air Conditioners. Vert-I-Pak Single Package Vertical Air Conditioners Vert-I-Pak Installs easily in a closet for quiet operation and provides a more homelike appearance for your guests. THE EXPERTS IN ROOM AIR CONDITIONING A Better

More information

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS Céliera Corporation. All rights reserved. Unauthorized duplication, reproduction prohibited. CONTENTS SAFETY PRECAUTIONS...

More information

Pioneer in sustainability

Pioneer in sustainability Pioneer in sustainability Over 100 years ago Carrier helped pioneer a new industry, and in the last two decades we have pioneered environmentally sensitive products with a reduced impact on the environment.

More information

Comfort... where you need it, when you need it. Ductless Mini-Split Systems

Comfort... where you need it, when you need it. Ductless Mini-Split Systems Comfort... where you need it, when you need it Ductless Mini-Split Systems Comfort... it s what we re all about At Comfort-Aire, we re in the business of making you comfortable, whether at home, work,

More information

Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify

Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify Comfort Control Center 2 Thermostat Operating Instructions Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify TABLE OF CONTENTS About your new thermostat Features...2

More information

To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)

To suit Daikin FDY F Series and FD F Series. (and other models incorporating BRC1B62/52 Remote Controller) OPERATION MANUAL Split System Ducted Air Conditioner To suit Daikin FDY "F" Series and FD "F" Series AIR CONDITIONER A hr o C (and other models incorporating BRC1B62/52 Remote Controller) Dear Owner, Thank

More information

NEW 3-PIPE ECOi MF2 SERIES

NEW 3-PIPE ECOi MF2 SERIES NEW 3-PIPE ECOi MF2 SERIES SIMULTANEOUS HEATING AND COOLING VRF SYSTEM Internet Control Ready INTERNET CONTROL NEW Energy Environmentally friendly refrigerant R410A Down to -20 ºC in heating mode OUTDOOR

More information