* Rev A* PN Rev A 1
|
|
- Randolph Phelps
- 8 years ago
- Views:
Transcription
1 AT-S70 Version Management Software for the Converteon Media Converter Products Software Release Notes Please read this document before you begin to use the management software. Supported Platforms The AT-S70 Version is supported on the Converteon Media Converter products. Converteon Chassis AT-CV5000 AT-CV1000 AT-CV1200 Converteon Line Cards AT-CM201 AT-CM202 AT-CM202/1 AT-CM202/2 AT-CM212A/1 AT-CM212B/1 AT-CM70S AT-CM2K0S AT-CV101 AT-CV102 AT-CV102/1 AT-CV102/2 AT-CV1KSS Power supplies and other modules AT-PWR14 AT-PWR15 AT-CV5M01 AT-CV5LED * Rev A* PN Rev A 1
2 Product Documentation For hardware installation instructions, refer to the following guides: AT-CV5000 Chassis Installation Guide (PN ) AT-CV1200 Chassis Installation Guide (PN ) AT-CV1000 Chassis Installation Guide (PN ) Converteon Line Cards Quick Install Guides (PN varies) Converteon Line Cards Reference Guide ( ) For management instructions, refer to the following guide: AT-S70 Management Software User s Guide (PN ) All documents are available from the Allied Telesis web site at PN Rev A 2 Allied Telesis, Inc.
3 What s New in Version This section lists new hardware and software features supported in AT-S70 Version Software Features No new software features have been added in this release. Hardware Features No new hardware features have been added in this release. Known Issues The system date and time are not the real date and time. They appear to be dependent on the system run time. For example, if the date and time are configured and the system reboots, the date and time reset back to 0, and accumulate with system run time. (2700) Workaround: After resetting the system, the user can input the actual date and time via the system menu. Event Log does not display when the CPM card is reset. When the user reset the CPM/Line Card from the Module Status and Config Menu, the event does not get logged in the Event Log menu. (4082) Workaround: Reset the CPM or line card; then view the Event Log from the Administration Menu. Port A (SFP) of AT-CM70S cannot be disabled. (4415) When an individual fan stops within the AT-CV5000 chassis, an SNMP trap is sent indicating a fan module has been removed instead of indicating a fan failure. In addition, when the fan resumes an SNMP trap is sent indicating a fan module has been installed instead of indicating a fan recovery for this event. (4480) When using the SNMP interface, the same sysoid is returned by both the AT-CV5000 and the AT-CV1200 chassis. (4997) When an AT-CM2K0S line card is in the Missing Link mode and the link for the copper port (RJ-45) goes down, the fiber activity (AT) LED illuminates to a solid green with no traffic present. (5092) If an AT-CM2K0S line card has a single mode SFP (LX) module installed and the fiber cable is plugged in and then unplugged multiple times, the fiber link LED may stay on when the cable is unplugged and the Port A module status may show ON-LINE. (5017, 5073) Workarounds: Any of the following workarounds will resolve this issue: By plugging the fiber cable into the SFP port and unplugging it once more, the fiber link LED will go off. By unplugging the copper cable from the RJ-45 connector, the fiber LED will go off. By performing a hardware reset for the AT-CM2K0S line card, the fiber LED will go off. When using the OAM feature to access a remote module, do not disable the remote port. If you do disable the remote port, no remote recovery is possible via the OAM interface. (5099) Workaround: Re-enable the fiber port at the remote site via the local management software. PN Rev A 3 Allied Telesis, Inc.
4 Operational Notes AT-CV Series line cards support jumbo frames and the AT-CM Series line cards support up to the maximum frame size of 1518 bytes (untagged). For MissingLink feature in the AT-CM202 and AT-CM212 line cards to function properly, after connecting a cable (linked) to any port on the line card, it takes up to 3 seconds for the port s LINK LEDs to turn ON. If you receive a line card where its mode switches do not function or are disabled; that line card may be configured in an Operating Mode other than Line Card Management Mode. Workaround: If you have an AT-CV5M01 Control Processor Module (CPM) card installed in your system, you need to reconfigure the Operating Mode of the line card to Line Card Management Mode via the management interface. If you do not have an AT-CV5M01 CPM card in your system, contact Allied Telesis technical support at The following parameters are fixed on the AT-CV1xx Series modules and cannot be changed through the management interface: Auto-Negotiation Port Enable/Disable on the copper port. The following parameters can be changed on the AT-CV1xx Series modules through the management interface: Link Test MissingLink TM Smart MissingLink Line Card Management Mode If your AT-CV5000 chassis has an AT-CV5M01 CPM card with ten or more line modules, you should wait up to 10 minutes after applying power to the chassis before you proceed with configuring and managing each of the modules. This allows time for the initial detection of the modules and for the correct status to be displayed for each module in the management software. If you do not have an AT-CV5M01 CPM card installed, then this note does not apply. If you are adding more modules to an operational AT-CV5000 chassis or hot-swapping modules, it is recommended to install each additional module one at a time and wait until the module status is properly displayed in the management software before adding the next module. Prior to installing the AT-CM70S module into an AT-CV1200 chassis, the UART configuration setting must be set to the UART Local Console Mode. (The UART Local Console Module is the factory default setting of the module.) If the AT-CM70S module is reconfigured via the AT- S70 management software in the AT-CV5000 chassis to the UART Backplane Mode and is then transferred to an AT-CV1200 chassis, it will not function properly. (5015) Workaround: Before transferring an AT-CM70S module from an AT-CV5000 chassis to an AT-CV1200 chassis, reconfigure the UART configuration setting to the UART Local Console Mode. Refer to the AT-S70 Converteon Management Software User s Guide for assistance. PN Rev A 4 Allied Telesis, Inc.
5 Features History This section lists the history of the AT-S70 Management Software s features. Version None Version None Version SNMP, v3 T1/E1 Configuration and Status (for AT-CM70S only) Version Redundant CPM (Manual and Automatic CPM Switchover) ATI Proprietary Remote Management with Remote Port Configuration Included Smart MissingLink SFP Information Version The AT-S70 Version introduced the following new features: Event Log Syslog (RFC BSD Syslog Protocol) User Configurable for Operating Mode via User Interface MissingLink capability for AT-CM202 Line Card Version The AT-S70 Version introduced the following new features: Chassis, CPM card and line card monitoring and diagnostics Telnet and SNMP management Xmodem and TFTP software downloads DHCP Activity Monitor IEEE 802.3ah OAM Compatible ATI Proprietary Remote Status PN Rev A 5 Allied Telesis, Inc.
6 Resolved Issues History This section lists the history of the AT-S70 Management Software s resolved issues. Version The following issues were resolved in AT-S70 Version Maximum packet size supported by AT-CM Series line cards. In AT-S70 V1.4.0, the maximum packet size supported by AT-CM Series line cards is 1518 (untagged) and 1522 (tagged). (4513) AT-CM2K0S intermittent issues related to ML/SML. The AT-CM2K0S may have intermittent issues after the fiber or copper cable is unplugged and plugged back in while in the OAM mode. Also, the AT-CM2K0S may have intermittent issues after the Operating Mode configuration has been reconfigured. This issue is most prevalent when the Operating Mode is changed to either MissingLink (ML) or Smart MissingLink (SML) (4462, 4586). Version The following issues were resolved in AT-S70 Version CONVERTEON AT-CV5000 Chassis Shows Wrong FAN Info. If the fan module is not present, the Fan Status in the Diagnostics Menu is displayed as Failed. (2759) Workaround: Reset the system time and date after a system reboot. OAM Mode Changes Not Taking Effect When Changed. Changes to OAM mode (Active/ Passive) do not take effect when changed. Workaround: Toggle the Administration state to disable, then re-enable. (3318) AT-CM2xx Series Line Cards May Experience Packet Loss. The AT-CM2xx Series line cards may experience a packet loss when used in a managed environment with AT-CV5M01 CPM card and the AT-CV5000 chassis. (4219) Workaround: AT-CM2xx Series line cards have no issues in an unmanaged environment. Version The following issues were resolved in AT-S70 Version Line Cards Take Several Retries to Transfer New Software. When downloading AT-S73 software to individual line cards, kilobyte accumulation may pause, and an 'Ack not received' message may be displayed. This indicates an interruption in the transmission from the CPM to the line cards. The system will automatically re-establish transmission and continue updating the line card software (3124). Switching Port Configuration From Auto to Full/Half-Duplex Does Not Take on First Attempt. When switching a line card port configuration from Auto-Negotiate to full or half-duplex, the software cursor may not move and highlight the selected option. When this occurs, the duplex setting (full or half) needs to be selected and confirmed (by pressing the Enter key) one more time. Proper cursor placement and selection highlighting confirm the configuration update (3183). MissingLink Feature Behaves Incorrectly During Initial Power-Up State. During the initial power-up state, if the fiber port is connected before the copper port, it will cause the MissingLink feature to behave incorrectly later on. (3257) Workaround: For the MissingLink feature to function correctly, perform one of the following methods: PN Rev A 6 Allied Telesis, Inc.
7 * Make sure the copper and fiber ports are not connected (not linked) during the initial line card power-up. * Connect the copper port before the fiber port during the initial line card power-up. Module Status/Configuration Display Text Changes When Line Card Experiences Interruption. The module status/configuration display text may change when the line card is experiencing an interrupt (e.g. line card insertion, line card removal, port up, port down, etc ). (3258) Periodic 0x1858 Packets Seen from AT-CM Series Line Cards. Periodic 0x1858 packets related to in-band management may be seen from the copper ports of the AT-CM Series line cards. (3315) Version The following issues were resolved in AT-S70 Version OAM Configuration Menu Displays Erroneous Menu Selections. When a port is configured in OAM Enabled/Active mode and the link status changes to either Link or No Link, the OAM Configuration menu can display erroneous menu selections when the user scrolls up or down on the menu. Fan Tray 2 Alerts Not Displayed. If system temperature exceeds the configured temperature threshold, temperature alert message for fan trays will be sent to Activity Monitor, EventLog, SysLog, and SNMP trap. A 'recovered' message for fan tray 2 or fan trays 2 and 1 may be sent without true temperature recovery (3080). Line Card Front LED Not Reflecting the Software Configured Operating Mode. The front mounted ML LED indicator on AT-CM202 and AT-CM212 line cards do not illuminate when a line card is configured for MissingLink operating mode. The LED will illuminate when a line card is not configured for MissingLink (3090). Operator Level User Perform 'Manager Level' Operations. (3165) Operator level user does not have access to view or configure the following system submenus: 'Omega Options' & 'Terminal Configuration' and LC 'Port Configurations' & 'Configure Operating Mode'. Operator level user can configure speed and duplex setting on CPM Ethernet port and start/stop system logging. Pinging Remote System From Telnet Not Displaying Ping Results. When using the 'Ping remote host' feature from a Telnet session, the individual ping results do not display in the Telnet window, and are outputted to the console port (3175). Can Not Enable/Disable Line Card Ports. The 'enable/disable port' feature for individual line card ports is not available in current release. Ports operate as enabled (3176). After Power Cycle, Line Card Configurations Become Distinguishable; No Cursor or Highlighted Options. Default configuration settings for line card ports, including speed and duplex, are not initially highlighted in the system software. Once they are configured by the user, the settings will remain highlighted (3177) MissingLink on AT-CM202 and AT-CM212 Line Card Not Operating According to MissingLink Standard. When a line card is configured for Missing Link operating mode, the link LED on port A may not shut off when the link on port B is dropped. Port A link on the far end line card will be dropped and its LED will turn off (3182). PN Rev A 7 Allied Telesis, Inc.
8 Port Link and Fan Failure/Recover Event Messaging Not Sent. The following events do not trigger messaging alerts via Activity Monitor, EventLog, SysLog, and SNMP traps: port link online/offline, fan x of 2 failure/recover on fan tray x (3188). Version The following issues were resolved in AT-S70 Version Software/Firmware Revision Identification-Enhancement. Diagnostic Menu does not display Software and Firmware Revision Identification. This issue has been resolved (2923) After Image Download, Software Reports the Line Card Status as ON Before the Card s LED Turns On. After image download, software reports the line cards status as Online before the card s LED turns on. The line card is not functionally ready until the LEDs illuminate. This issue can be cleared by power-cycle. This issue has been resolved (2938). Operator Level User Can Enable/Disable DHCP. A user at Operator level can enable/ disable DHCP. This should be a Manager level function. This issue has been resolved (2968). DIP Lock Menu Not Operational. The DIP Lock menu is not operational in this firmware release. This issue has been resolved. ATI Remote Management Configuration Menu Not Operational. The ATI Remote Management Configuration menu is not operational in this firmware release. This issue has been resolved. PN Rev A 8 Allied Telesis, Inc.
9 Contacting Allied Telesis This section provides Allied Telesis contact information for technical support as well as sales or corporate information. Online Support You can request technical support online by accessing the Allied Telesis Knowledge Base at You can use the Knowledge Base to submit questions to our technical support staff and review answers to previously asked questions. and Telephone Support For Technical Support via or telephone, refer to the Support & Services section of the Allied Telesis web site: Returning Products Products for return or repair must first be assigned a return materials authorization (RMA) number. A product sent to Allied Telesis without an RMA number will be returned to the sender at the sender s expense. To obtain an RMA number, contact Allied Telesis Technical Support group through our web site: For Sales or Corporate Information You can contact Allied Telesis for sales or corporate information on four web site: To find the contact information for your country, select Contact Us -> Worldwide Contacts. Obtaining Management Software Updates New releases of management software for our managed products are available from either of the following Internet sites: Allied Telesis web site: Allied Telesis FTP server: ftp://ftp.alliedtelesis.com You must have FTP client software to download new software from the Allied Telesis FTP server from your workstation s command prompt and you must log in to the server. The user name is anonymous and your address is the password. PN Rev A 9 Allied Telesis, Inc.
AT-S99 and AT-S102 Version 5.0.0 Management Software for the Converteon Media Converter Products. Software Release Notes
AT-S99 and AT-S102 Version 5.0.0 Management Software for the Converteon Media Converter Products Software Release Notes Please read this document before you begin to use the management software. Software
More informationAT-S45 Version 1.0.7 Management Software for the AT-9410GB Gigabit Ethernet Switches. Software Release Notes
AT-S45 Version 1.0.7 Management Software for the AT-9410GB Gigabit Ethernet Switches Product Documentation Software Release Notes Please read this document before you begin to use the AT-S45 management
More informationAT-S41 Version 1.1.4 Management Software for the AT-8326 and AT-8350 Series Fast Ethernet Switches. Software Release Notes
AT-S41 Version 1.1.4 Management Software for the AT-8326 and AT-8350 Series Fast Ethernet Switches Software Release Notes Please read this document before you begin to use the AT-S41 management software.
More informationAT-S60 Version 1.1.4 Management Software for the AT-8400 Series Switch. Software Release Notes
AT-S60 Version 1.1.4 Management Software for the AT-8400 Series Switch Supported Platforms Software Release Notes Please read this document before you begin to use the AT-S60 management software. The AT-S60
More informationAT-S84 Version 1.3.0 (1.0.0.90) Management Software for the AT-9000/24 Gigabit Ethernet Switch Software Release Notes
AT-S84 Version 1.3.0 (1.0.0.90) Management Software for the AT-9000/24 Gigabit Ethernet Switch Software Release Notes Please read this document before you begin to use the management software. Supported
More informationHow To Install An At-S100 (Geo) On A Network Card (Geoswitch)
AT-S100 Version 1.0.3 Patch 1 Management Software for the AT-9000/28 Managed Layer 2 GE ecoswitch and AT-9000/28SP Managed Layer 2 GE ecoswitch Software Release Notes Please read this document before you
More informationManagement Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev.
Management Software AT-S106 Web Browser User s Guide For the AT-GS950/48 Gigabit Ethernet Smart Switch Version 1.0.0 613-001339 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of
More informationCommand Line Interface User s Guide
Management Software AT-S85 and AT-S97 Command Line Interface User s Guide AT-MCF2000 Media Converter Series Version 1.3.0 613-000789 Rev. A Copyright 2007 Allied Telesis, Inc. All rights reserved. No part
More informationCommand Line Interface User s Guide
Management Software AT-S85 and AT-S97 Command Line Interface User s Guide AT-MCF2000 Media Converter Series Version 2.0.0 613-000789 Rev. C Copyright 2008 Allied Telesis, Inc. All rights reserved. No part
More informationAT-S105 Version 1.2.0 Management Software Release Notes AT-FS750/24POE and AT-FS750/48 Fast Ethernet WebSmart Switches
AT-S105 Version 1.2.0 Management Software Release Notes AT-FS750/24POE and AT-FS750/48 Fast Ethernet WebSmart Switches Please read this document before you begin to use the management software. NOTE This
More informationAT-S95 Version 1.0.0.35 AT-8000GS Layer 2 Stackable Gigabit Ethernet Switch Software Release Notes
AT-S95 Version 1.0.0.35 AT-8000GS Layer 2 Stackable Gigabit Ethernet Switch Software Release Notes Please read this document before you begin to use the management software. Supported Platforms The following
More informationAT-S63 and AT-S63 NE Version 1.0.0 Management Software for the AT-9400 Series Layer 2+ Gigabit Ethernet Switches Software Release Notes
AT-S63 and AT-S63 NE Version 1.0.0 Management Software for the AT-9400 Series Layer 2+ Gigabit Ethernet Switches Software Release Notes Supported Platforms Please read this document before you begin to
More informationAT-S63 Version 3.2.1 Patch 5 Management Software for the AT-9400 Basic Layer 3 Gigabit Ethernet Switches Software Release Notes
AT-S63 Version 3.2.1 Patch 5 Management Software for the AT-9400 Basic Layer 3 Gigabit Ethernet Switches Software Release Notes Please read this document before you begin to use the management software.
More informationManagement Software. User s Guide AT-S88. For the AT-FS750/24POE Fast Ethernet Smart Switch. Version 1.0. 613-000555 Rev. B
Management Software AT-S88 User s Guide For the AT-FS750/24POE Fast Ethernet Smart Switch Version 1.0 613-000555 Rev. B Copyright 2007 Allied Telesis, Inc. All rights reserved. No part of this publication
More informationManagement Software. User s Guide AT-S84. For the AT-9000/24 Layer 2 Gigabit Ethernet Switch. Version 1.1. 613-000368 Rev. B
Management Software AT-S84 User s Guide For the AT-9000/24 Layer 2 Gigabit Ethernet Switch Version 1.1 613-000368 Rev. B Copyright 2006 Allied Telesyn, Inc. All rights reserved. No part of this publication
More informationenetworks TM Using the Syslog Feature C.1 Configuring the Syslog Feature
encor! enetworks TM Version A, March 2010 2013 Encore Networks, Inc. All rights reserved. Using the Syslog Feature This document provides basic information for using the syslog feature in the ELIOS software.
More informationAT-S63 Version 3.1.0 Management Software for the AT-9400 Basic Layer 3 Gigabit Ethernet Switches Software Release Notes
AT-S63 Version 3.1.0 Management Software for the AT-9400 Basic Layer 3 Gigabit Ethernet Switches Software Release Notes Please read this document before you begin to use the management software. Supported
More informationStarting a Management Session
Management Software AT-S63 Starting a Management Session AT-S63 Version 2.2.0 for the AT-9400 Layer 2+ Switches AT-S63 Version 3.0.0 for the AT-9400 Basic Layer 3 Switches 613-000817 Rev. A Copyright 2007
More informationAT-GS950/8. AT-GS950/8 Web Users Guide AT-S107 [1.00.043] Gigabit Ethernet Smart Switch. 613-001484 Rev A
AT-GS950/8 Gigabit Ethernet Smart Switch AT-GS950/8 Web Users Guide AT-S107 [1.00.043] 613-001484 Rev A Copyright 2011 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced
More informationAT-S62 and AT-S62 NE Version 1.2.1 Management Software for AT-8500 Series Switches Software Release Notes
Supported Platforms AT-S62 and AT-S62 NE Version 1.2.1 Software Release Notes AT-S62 and AT-S62 NE Version 1.2.1 Management Software for AT-8500 Series Switches Software Release Notes Please read this
More informationAT-S39 Version 3.1.1 Management Software for the AT-8000 Series Fast Ethernet Switches. Software Release Notes
AT-S39 Version 3.1.1 Management Software for the AT-8000 Series Fast Ethernet Switches Supported Platforms Software Release Notes Please read this document before you begin to use the AT-S39 management
More informationNetwork Power Manager. User Manual
Network Power Manager User Manual Table of Contents 1. Introduction... 1 2. PDU Package... 2 3. Function... 3 4. Installation... 4 5. Web Interface... 5 1. Introduction The PDU is an Internet ready device
More informationAT-S39 Version 1.3 Management Software for the AT-8024 and AT-8024GB Fast Ethernet Switches. Software Release Notes
AT-S39 Version 1.3 Management Software for the AT-8024 and AT-8024GB Fast Ethernet Switches Supported Platforms Software Release Notes Please read this document before you begin to use the AT-S39 management
More informationBercut-ETL Ethernet/Gigabit Ethernet loopback
Bercut-ETL Ethernet/Gigabit Ethernet loopback Operating manual Version 1.0.4, 2009 Metrotek c Metrotek, 2006 2010 No part of this document may be reproduced in any form or by any means without the written
More informationACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4
ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4 1 PURPOSE:... 1 2 CPM-4/CPM-2 COMPATIBILITY... 2 2.1 NETWORK CABLES... 2 2.2 FACTORY DEFAULT SETTINGS... 2 2.3 CHANGING THE RS-232 SERIAL PORT BAUD
More informationAlliedWare Plus Version 2.1.2 AT-9000 Layer 2-4 Gigabit Ethernet EcoSwitches Software Release Notes
4 AlliedWare Plus Version 2.1.2 AT-9000 Layer 2-4 Gigabit Ethernet EcoSwitches Software Release Notes Please read this document before you begin to use the management software. The document has the following
More informationUSER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks
USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St. Neihu,
More informationHow to Log On... 15 Main Screen... 18 Control Console Menus... 21. How to Log On... 24 Summary Page... 27 Navigation Menu... 29
Contents Introduction--1 Product Description.................................. 1 Access Procedures.................................... 3 How to Recover From a Lost Password..................... 6 Upgrading
More informationPerle Protocol Transparent Media Converter Modules
Perle Protocol Transparent Media Converter Modules Installation Guide C-4GPT-DSFP CM-4GPT-DSFP Part# 5500335-10 Overview This document contains instructions necessary for the installation and operation
More information24 Port Gigabit Ethernet Web Smart Switch. Users Manual
24 Port Gigabit Ethernet Web Smart Switch Users Manual Content Web Smart Switch Configure login -------------------------------- 2 Configuration System Configuration ---------------------------------------------------
More informationProduct Description... 1 Internal Management Features... 3 Front Panel... 5 Watchdog Features... 7
Contents Introduction--1 Product Description.................................. 1 Internal Management Features........................... 3 Front Panel........................................ 5 Watchdog
More informationTitle Page Web/SNMP Management SmartSlot Card
Title Page Web/SNMP Management SmartSlot Card AP9606 User s Guide Thank You! Thank you for selecting the APC Web/SNMP Management SmartSlot Card. It has been designed for many years of reliable, maintenance-free
More informationManaged Switch Quick Start Guide
Managed Switch Quick Start Guide Note: The purpose of this guide is to help you get your Hirschmann managed switch up & running as quickly as possible and recommend switch settings that are suitable for
More informationReboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive
Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive This guide explains how to create and use a Rescue USB flash drive to reinstall and recover the ExtraHop system. When booting
More informationTechnical Overview CM-16 Climate Monitor. Get yours direct at: 01491 410913 www.theclimate.co.uk
Technical Overview CM-16 Climate Monitor Get yours direct at: 01491 410913 www.theclimate.co.uk Need a lot of remote sensors in a rack mount? The CM-16 has web access, graphing, and alarm alerts sent by
More informationPrestige 310. Cable/xDSL Modem Sharing Router. User's Guide Supplement
Prestige 310 Cable/xDSL Modem Sharing Router User's Guide Supplement Domain Name Support Enhanced WAN Setup Remote Node Support PPPoE Support Enhanced Unix Syslog Setup Firmware and Configuration Files
More informationNote: This case study utilizes Packet Tracer. Please see the Chapter 5 Packet Tracer file located in Supplemental Materials.
Note: This case study utilizes Packet Tracer. Please see the Chapter 5 Packet Tracer file located in Supplemental Materials. CHAPTER 5 OBJECTIVES Configure a router with an initial configuration. Use the
More informationQuick Start Guide. Cisco Small Business. 200E Series Advanced Smart Switches
Quick Start Guide Cisco Small Business 200E Series Advanced Smart Switches Welcome Thank you for choosing the Cisco 200E series Advanced Smart Switch, a Cisco Small Business network communications device.
More informationUPS Network Interface. Quick InstallationGuide
UPS Network Interface Quick InstallationGuide Version 1.1 March 1999 COPYRIGHT Copyright 1999 RINGDALE UK Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed,
More informationUser s Manual Network Management Card
User s Manual Network Management Card RMCARD202 Intelligent Network Management Card allows a UPS system to be managed, monitored, and configured Version 1.0 E-K01-SNMP005-0 TABLE OF CONTENTS Introduction
More informationAlarm Messages... 15 Clearing the Hardware Alarms... 16. How to Log On... 17 Summary Page... 21 Navigation Menu... 24
Contents Introduction--1 Product Description.................................. 1 Access Procedures................................... 3 How to Recover from a Lost Password..................... 6 Upgrading
More informationQuick Start Guide. Cisco Small Business. 300 Series Managed Switches
Quick Start Guide Cisco Small Business 300 Series Managed Switches Welcome Thank you for choosing the Cisco 300 Series Managed Switch, a Cisco Small Business network communications device. This device
More informationWireless Router Setup Manual
Wireless Router Setup Manual NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10082-02 2006-04 2006 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR is a trademark of Netgear,
More informationPandora FMS 3.0 Quick User's Guide: Network Monitoring. Pandora FMS 3.0 Quick User's Guide
Pandora FMS 3.0 Quick User's Guide April 27th, 2009 1 Contents How to monitor a network computer/device?...3 Concepts...3 What's an agent?...3 What's a module?...3 Data transfer modes...3 What is an alert?...3
More informationArchitectural/Engineering Specification for an. Industrial, Managed, Cyber Protected. Ethernet Switch TUNGSTEN
Architectural/Engineering Specification for an Industrial, Managed, Cyber Protected Ethernet Switch TUNGSTEN Sep. 26, 2014 Page 1 of 15 Ver. 1.01 This document is intended to provide performance specifications
More informationHow To Configure Voice Vlan On An Ip Phone
1 VLAN (Virtual Local Area Network) is used to logically divide a physical network into several broadcast domains. VLAN membership can be configured through software instead of physically relocating devices
More informationOlson Electronics Remote Power Monitoring Meter
Olson Electronics Remote Power Monitoring Meter Operation Guide Key Features Amps: 00.00 to 32.00A True RMS (rated short period to 40A) Volts: 200.0 to 250.0V True RMS Watts: 0000 to 9999W KWh: 000000.0
More informationALLNET ALL-SG8926PM Layer 2 FULL Management 24 Port Giga PoE Current Sharing Switch IEEE802.3at/af
ALLNET ALL-SG8926PM Layer 2 FULL Management 24 Port Giga PoE Current Sharing Switch IEEE802.3at/af 24-Port Giga PoE Current Sharing 500W PoE Budget IPv6 and IPv4 Dual Protocol SNMP v1/v2c/v3 SSH version
More information16-PORT POWER OVER ETHERNET WEB SMART SWITCH
16-PORT POWER OVER ETHERNET WEB SMART SWITCH User s Manual (DN-95312) - 0 - Content Web Smart Switch Configure login ---------------------------------- 2 Administrator Authentication Configuration ---------------------------------------------
More informationMFC7840W Windows Network Connection Repair Instructions
Difficulty printing from your PC can occur for various reasons. The most common reason a networked Brother machine may stop printing, is because the connection between the computer and the Brother machine
More information10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable
10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable StarTech ID: IES101002SFP The IES101002SFP 10-port Ethernet switch delivers flexibility and control of your network by
More informationSNAP Printer Web Server Users Manual
User s Manual SNAP Printer Web Server Users Manual AVERY DENNISON 29 April 2013 Version 1.2 Change List Version Description 1.0 Initial Release 1.1 Updated to add the Batch ID and Batch Count to the main
More informationSwitch Quick Configuration CLI Guide for
Switch Quick Configuration CLI Guide for SSE-G48-TG4 SSE-G24-TG4 SSE-X24S SSE-X24SR SSE-X3348S SSE-X3348SR SSE-X3348T SSE-X3348TR SBM-GEM-X2C SBM-GEM-X2C+ SBM-GEM-X3S+ SBM-XEM-X10SM Release : 1.0d 1 /
More informationEmerson Smart Firewall
DeltaV TM Distributed Control System Product Data Sheet Emerson Smart Firewall The Emerson Smart Firewall protects the DeltaV system with an easy to use perimeter defense solution. Purpose built for easy
More informationCarrier Ethernet: New Game Plan for Media Converters
Introduction IEEE Std. 802.3ah, also referred to as Ethernet in the First Mile (EFM) standard, has a well established name within the industry today. It lays out ground rules for implementing Ethernet
More informationFocal Point 2.1 Management Software & CPSMM100 Firmware Manual
Focal Point 2.1 Management Software & CPSMM100 Firmware Manual Manual 33293 Rev B Focal Point Management Software Transition Networks Table of Contents Section I:...1 Introduction...1 About this manual...2
More informationFile Transfers. Contents
A File Transfers Contents Overview..................................................... A-2................................... A-2 General Switch Software Download Rules..................... A-3 Using
More informationAvediaStream c1110 Chassis. c1110 Chassis Monitor V1.0. Administrator s Guide
AvediaStream c1110 Chassis c1110 Chassis Monitor V1.0 Administrator s Guide Notices Exterity Limited 2012 This document contains information that is protected by copyright. Reproduction, adaptation, or
More informationFile Transfers. Contents
A File Transfers Contents Overview..................................................... A-2................................... A-2 General Switch Software Download Rules..................... A-3 Using
More informationIxia Director TM. Powerful, All-in-One Smart Filtering with Ultra-High Port Density. Efficient Monitoring Access DATA SHEET
Ixia Director TM Powerful, All-in-One Smart Filtering with Ultra-High Port Density The Ixia Director TM is a smart filtering appliance that directs traffic of interest to your monitoring tools. Now you
More informationPort Trunking. Contents
12 Port Trunking Contents Overview..................................................... 12-2................................... 12-2 Port Connections and Configuration.......................... 12-3 Link
More informationEnvironmental Management System
Contents Introduction--1 Product Description.................................. 1 Access Procedures................................... 3 How to Recover from a Lost Password..................... 6 Upgrading
More informationRS-232/422/485 to 10/100Base-TX Device Server / Managed Media Converter (IRF-633) User s Manual
RS-232/422/485 to 10/100Base-TX Device Server / Managed Media Converter (IRF-633) User s Manual COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system,
More informationEasy Smart Configuration Utility
Easy Smart Configuration Utility REV1.1.0 1910010977 CONTENTS Chapter 1 About this Guide...1 1.1 Intended Readers... 1 1.2 Conventions... 1 1.3 Overview of This Guide... 1 Chapter 2 Getting Started...4
More informationSection 11.1, Simple Network Management Protocol. Section 11.2, Port Data Capture
Chapter 11 SNMP and Port Data Capture This module discusses the Simple Network Management Protocol (SNMP) and the BANDIT device s Port Data Capture feature, and how they can be used to augment or enhance
More informationChapter 10 Troubleshooting
Chapter 10 Troubleshooting This chapter explains how you can troubleshoot a specific problem, such as abnormal LED activity or no system power, when you power up the router. Topic Page Diagnosing Problems
More informationManual. IP Sensor and Watchdog IPSW2210. I P S W 2 2 1 0 M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.
IP Sensor and Watchdog IPSW2210 Manual Relay Output Power input 12VDC adapter LED Indicators 1 wire 2 Dry Output Green : Power Yellow: Link temperature & humidity contact inputs LED indicator sensor input
More informationNetwork Management Card. User Manual
User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1
More informationAP-GSS3000 TM 512Ch GSM SIM Server
AP-GSS3000 TM 512Ch GSM SIM Server High Performance GSM SIM Server Solution Preliminary Product Overview (Without notice, following described technical spec. can be changed) www.addpac.com AddPac Technology
More informationMonitoring and Analyzing Switch Operation
B Monitoring and Analyzing Switch Operation Contents Overview..................................................... B-3....................................... B-4 Menu Access To Status and Counters.........................
More informationLegal Disclaimers. For C-UL Listed applications, the unit shall be installed in accordance with Part 1 of the Canadian Electrical Code.
ACS5000 Networking Admin Interface Guide 1/21/2015 Legal Disclaimers Federal Communications Commission (FCC) Compliancy This equipment has been tested and found to comply with the limits for a Class B
More informationMFC6490CW Windows Network Connection Repair Instructions
Difficulty printing from your PC can occur for various reasons. The most common reason a networked Brother machine may stop printing, is because the connection between the computer and the Brother machine
More informationUnpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.
About This Guide This guide contains step-by-step instructions for setting up the D-Link DFL-260E/860E Firewall. Please note that the model you have purchased may appear slightly different from those shown
More informationNetwork Management Card
Network Management Card AP9617 AP9618 AP9619 Installation and Quick-Start Manual How to Avoid Equipment Damage Disconnect UPS power You do not need to turn off a Symmetra or a Silcon model UPS to install
More informationAll other brands and their products are trademarks or registered trademarks of their respective holders, and should be noted as such.
Administration Guide June 20, 2006 Copyright 2006 by Equitrac Corporation All rights to this document, domestic and international, are reserved by Equitrac Corporation. No part of this publication may
More informationEthernet Interface Manual Thermal / Label Printer. Rev. 1.01 Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2
Ethernet Interface Manual Thermal / Label Printer Rev. 1.01 Metapace T-1 Metapace T-2 Metapace L-1 Metapace L-2 Table of contents 1. Interface setting Guiding...3 2. Manual Information...4 3. Interface
More informationExploring the Remote Access Configuration Utility
Exploring the Remote Access Configuration Utility in Ninth-Generation Dell PowerEdge Servers The Remote Access Configuration Utility supports local and remote server management in ninth-generation Dell
More informationSecureLinx Spider Duo Quick Start Guide
SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo QUICK START GUIDE CONTENTS Overview... 2 What s In The Box... 3 Installation and Network Settings...
More informationPerle 10/100/1000 Ethernet Media Converter Module
Perle 10/100/1000 Ethernet Media Converter Module Installation Guide C-1110-XXXXX CM-1110-XXXXX C-1110-SFP CM-1110-SFP Unmanaged Module Managed Module Unmanaged Module Managed Module P/N 5500308-21 Overview
More informationReadyNAS OS 6 Desktop Storage Systems
ReadyNAS OS 6 Desktop Storage Systems Hardware Manual Models: ReadyNAS 102 ReadyNAS 104 ReadyNAS 312 ReadyNAS 314 ReadyNAS 316 ReadyNAS 516 ReadyNAS 716X EDA 500 October 2013 202-11206-04 350 East Plumeria
More informationTable of Contents. Network Critical NA LLC Tel: 716-558-7280 37 Franklin Street, Suite 100 Email: sales-us@networkcritical.com
Product Catalog Table of Contents Breakout TAPs...1-3 Fixed Aggregating Portable TAP...4-5 V-Line TM (Bypass) Portable TAPS...6 Breakout Portable TAP...7 V-Line (Bypass) TAPs...8-9 Smart Network Access
More informationChapter 7 Configuring Trunk Groups and Dynamic Link Aggregation
Chapter 7 Configuring Trunk Groups and Dynamic Link Aggregation This chapter describes how to configure trunk groups and 802.3ad link aggregation. Trunk groups are manually-configured aggregate links containing
More informationUnderstanding DRAC/MC Alerts
Understanding DRAC/MC Alerts The Dell Remote Access Controller/Modular Chassis (DRAC/MC) provides various alerting mechanisms by which administrators can monitor and manage the components within a Dell
More information8-Port Gigabit managed POE Switch. User s Manual. Version: 2.3
8-Port Gigabit managed POE Switch User s Manual Version: 2.3 September 9, 2007 1 TABLE OF CONTENT 1.0 INTRODUCTION... 3 1.1 MAIN FEATURES... 3 1.2 START TO MANAGE THIS SWITCH... 5 2.0 WEB MANAGEMENT...
More informationIP Phone Configuration and Troubleshooting Guide
IP Phone Configuration and Troubleshooting Guide NetVanta 7000 Series and IP 700 Series Phones Overview The purpose of this guide: Explain the default configuration. Explain how to configure the NetVanta
More informationCommand Line User s Guide
Management Software AT-S63 Command Line User s Guide For AT-9400 Switch Stacks AT-S63 Version 3.2.0 for AT-9400 Basic Layer 3 Switches 613-001027 Rev. A Copyright 2008 Allied Telesis, Inc. All rights reserved.
More informationRead Me First for the HP ProCurve Routing Switch 9304M and Routing Switch 9308M
Read Me First for the HP ProCurve Routing Switch 9304M and Routing Switch 9308M Contents: Software Updates Are Free! New Software Release 05.0.84 Module Installation Getting Started Your Free Ticket to
More informationCisco IOS XR Diagnostics
Cisco IOS XR online diagnostics allow you to test and verify hardware functionality while connected to a live network. Health-monitoring and scheduled diagnostics help ensure system high availability (HA).
More informationMICROSENS. Installation Switch with PoE (5x10/100Base-TX) and fiber uplink (1x100Base-FX) General. Features
Installation Switch with PoE (5x10/100Base-TX) and fiber uplink (1x100Base-FX) MICROSENS General The MICROSENS Installation Switch enables the connection of 5 end devices via twisted pair cable which also
More informationInfinity C Reference Guide
1 2! Infinity C Reference Guide Table of Contents Components... 1 Hardware Setup... 5 SmartDrive Configuration... 12 Startup... 15 Login... 16 System Configuration... 19 DICOM Setup... 20 Monitoring Status...
More informationUSER S GUIDE. network management card. Contents. Introduction--1. Control Console--13
Contents Introduction--1 Product Description.................................. 1 Functionality 1 Initial set-up 2 Network management features 3 Internal Management Features........................... 5
More informationNAS HARD DRIVE ENCLOSURE USER MANUAL. S T O R E n S H A R E MUSIC DATA PHOTO MOVIE
NAS HARD DRIVE ENCLOSURE USER MANUAL S T O R E n S H A R E MUSIC DATA PHOTO MOVIE w w w. v a n t e c u s a. c o m Package Contents: NexStar LX External 3.5 HDD NAS Enclosure: User Manual NexStar LX External
More informationUSER S GUIDE Switched Rack PDU
Contents Introduction--1 Product Description....................................... 1 Access Procedures....................................... 3 Recover From a Lost Password..............................
More informationAP-GSS1500 TM 256Ch GSM SIM Server High Performance GSM SIM Server Solution
AP-GSS1500 TM 256Ch GSM SIM Server High Performance GSM SIM Server Solution www.addpac.com AddPac Technology 2013, Sales and Marketing Contents Product Overview Hardware Specification SIM Bank Module Specification
More informationNetwork Management Card
Network Management Card Installation manual IP= MAC=00E0D8FF855E Reset 100 10 data Card Settings 1 2 RS232 Download ETHERNET RS232 66074 34003641EN/AG - Page 1 1 2 1 2 Quick start ASI or STS U-Talk ASI
More informationPrestige 202H Plus. Quick Start Guide. ISDN Internet Access Router. Version 3.40 12/2004
Prestige 202H Plus ISDN Internet Access Router Quick Start Guide Version 3.40 12/2004 Table of Contents 1 Introducing the Prestige...3 2 Hardware Installation...4 2.1 Rear Panel...4 2.2 The Front Panel
More informationTable of Contents. 1. Introduction...1. 2. PDU Package...2. 3. Function...3. 4. Installation...5. 5. Web Interface...7
PDU User Manual Table of Contents 1. Introduction...1 2. PDU Package...2 3. Function...3 4. Installation...5 5. Web Interface...7 1. Introduction The PDU is an Internet ready device designed and is equipped
More informationTDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module
Panduit Corp. 2010 TDP43ME NetPS PA26306A01 Rev. 01 11-2010 Network Printer Server Control Center for Ethernet Module NOTE: In the interest of higher quality and value, Panduit products are continually
More informationTechnical Overview CM-2 Climate Monitor. Get yours direct at: 01491 410913 www.theclimate.co.uk
Technical Overview CM-2 Climate Monitor Get yours direct at: 01491 410913 www.theclimate.co.uk The importance of effectively monitoring IT environments has never been greater. There are a multitude of
More informationWelcome. Unleash Your Phone
User Manual Welcome Unleash Your Phone For assistance with installation or troubleshooting common problems, please refer to this User Manual or Quick Installation Guide. Please visit www.vonage.com/vta
More information