qn=`i^ppf` qn=ifkbl=qo=ifkbl=qp=ifkbl=qq=ifkb
|
|
- Lucas Henderson
- 8 years ago
- Views:
Transcription
1 kéï=~ë=çñw= MRKOMNR qn=`i^ppf` qn=ifkbl=qo=ifkbl=qp=ifkbl=qq=ifkb lééê~íáåö=áåëíêìåíáçåë båöäáëü=erpf Operating Instructions =
2 Table of contents Sirona ental Systems GmbH Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE Table of contents 1 efore you begin Structure of the document Labeling of information Formats and symbols bbreviations/codes used Service life of Sirona instruments Safety information Technical description Task Functionality Structure of T1 LSSI Structure of T1 LINE Structure of T2 LINE Structure of T3 LINE ssembly of the T4 LINE Technical data Preparation Initial start-up and longer breaks in use Prior to starting the work day efore each patient Operation Replacing the instrument Inserting and removing burr instruments Inserting and removing an EV/G5 instrument Inserting and removing a prophylaxis instrument T1 LSSI PROPHY T1 LINE PROPHY T4 LINE H Inserting and removing an amalgam condenser instrument Inserting and removing ENO instruments ENO L ENO 6 L Recommendation for the treatment procedure
3 Sirona ental Systems GmbH Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE Table of contents 5.8 Mounting and removing the insulating sleeve Inserting and removing a Kirschner-Meyer instrument onnect and remove external spray Plugging in and removing the spray clip for NaI application Follow-up fter each treatment session t the end of the work day onditioning onduct pre-disinfection utomated cleaning and disinfecting with cleaning and disinfection equipment Manual cleaning and disinfection Manual maintenance Maintenance of mechanical parts are of the push button chuck Maintenance of cooling spray nozzles Sterilizing Maintenance Testing the FG clamping system Replacing the spray tube on the T1 LSSI KM 1.6 L Spare parts and consumables Storage and transport conditions isposal
4 1 efore you begin Sirona ental Systems GmbH Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE 1 Intended Use ontraindications Target group Scope of validity of operating instructions efore you begin T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE complies state-ofthe-art technical regulations. T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE complies with the ISO standard. Read/observe _ general 1. Read the operating instructions prior to using T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE. 2. Only use T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE for the applications described in the operating instructions. 3. Observe the applicable hygiene standards, occupational safety regulations and accident prevention measures for T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE. Holding and driving burr instruments _ rotary or oscillatory processing Straight and contra-angle handpieces T1 LINE ENO 6 L The contra-angle handpieces are used to hold and drive burr instruments for the purposes of rotary processing. The handpieces are intended for dental applications in endodontics and for root canal measurement and are used by trained dental personnel in dental practices and laboratories. The T1 Spray is intended to be used to clean and lubricate dental handpieces. T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE (except T1 LINE ENO 6 L) are intended for use in dental operatory to prepare dental cavities for restorations such as fillings, and for cleaning teeth. None trained dental personnel This product is intended only for use by trained dental personnel in dental practices and laboratories. Scope Instrument of validity These Operating Instructions are valid for the following instruments: T1 LSSI T1 LSSI from serial number T1 LINE T1 LINE from serial number T2 LINE T3 LINE T4 LINE T2 LINE T3 LINE T4 LINE
5 Sirona ental Systems GmbH Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE 1 efore you begin 1.1 Structure of the document 1.1 Structure of the document Labeling of information Warnings To prevent injuries, please observe all warnings. Warnings are labeled as follows: NGER! indicates a danger leading to death or serious injury if not avoided. WRNING! indicates a danger that may lead to death or serious injury if not avoided. UTION! indicates a danger that may lead to injury if not avoided. Instructions for use To prevent material damage and additional expenses, please observe all instructions for use. Instructions for use are labeled as follows: NOTIE! indicates measures for the prevention of material damage. IMPORTNT: indicates information on the avoidance of additional expenses and other important information. Tip: indicates information for facilitating work Formats and symbols The formats and symbols used in this document have the following meaning: Prerequisite 1. First action step 2. Second action step or lternative action Result Individual action step bbreviations/codes used Requests you to do something. Use of formats and symbols [ 5]. Identifies a reference to another text passage and specifies its page number. List Identifies a list. FG T1 LINE / T1 LSSI HP Friction grip burr instrument ontra-angle handpiece burr instrument Straight handpiece burr instrument
6 1 efore you begin Sirona ental Systems GmbH 1.2 Service life of Sirona instruments Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE 1.2 Service life of Sirona instruments Service life years / /2 years When used as intended: LSSI/T1-3 LINE LSSI / T1 LINE / T2 LINE / T3 LINE Standard_Sirona Non-moving parts of Sirona instruments have a typical service life of approx. 5 years Moving parts of Sirona instruments have a typical service life of approx. 3 years LINE T4 LINE Service life_fon Non-moving parts have a typical service life of 3 years Moving parts have a typical service life of 1.5 years No warranty claim can be inferred here, as wear may occur earlier or later than indicated above depending on use, frequency of sterilization, and frequency of maintenance
7 Sirona ental Systems GmbH Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE 2 Safety information 2 Safety information Obligations of the user Obligations of the user Use only fault-free materials that do not deviate from the specified Preventing the spread of infections and cross contamination Emitted cooling air Instrument head overheating Malfunction or damage Repair Spare and accessory parts First aid measures in the case of lubricant accidents data [ 11]. Protect yourself, patients, and others against any foreseeable dangers. To do this, follow the safety information. omply with the Intended use of the equipment. You should always keep these operating instructions within reach for further reference. ross Sterilization contamination and spread of infections Prevent the spread of infections and cross contamination between patients, users, and third parties. Sterilize equipment after each patient. Take the appropriate hygiene measures, e.g. wear protective gloves. Emitted cooling air The cooling air emitted by the coupling of the motor must have a flow rate of Nl/min. Keeping cooling air away To keep the cooling air coming out of the instrument away from the cavity, silicone disks are available [ 23]. Instrument head overheating If the instrument is defective, the area around the instrument head may heat up, thus creating a risk of burning the patient's oral mucosa. Malfunction / amage _ Instruments iscontinue use immediately in case of malfunction, unusual or different sounds or damage. amaged instruments may cause injury. Notify the dental depot or the manufacturer. Repair_instrument o not repair the instrument yourself. ccessory parts Use only original Sirona parts or parts approved by Sirona. Safe operation is not guaranteed for parts that have not been approved by Sirona. First aid _ US General information: fter inhalation: fter skin contact: fter eye contact: fter swallowing: Immediately remove any clothing soiled by the product. Supply fresh air; consult doctor in case of complaints. If skin irritation continues, consult a doctor. Rinse opened eye for several minutes under running water. If symptoms persist consult doctor. For details download the T1 Spray Material Safety ata Sheet from the Sirona homepage: If you have any questions, please contact your dental depot or the manufacturer
8 3 Technical description Sirona ental Systems GmbH 3.1 Task Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE 3 Technical description 3.1 Task Instrument The instrument transmits the driving power and speed of the electric motor or air motor to the preparation tool. 3.2 Functionality Instrument The transmission ratio of the instrument distorts the operating speed of the preparation tool. T1 LINE ONENS The rotary drive movement is converted into a vibration movement with the ONENS contra-angle handpiece. EV contra-angle handpiece The rotary drive movement is converted into a vertical reciprocating movement of 0.4 or 1.1 mm, respectively, with the EV contra-angle handpiece. ENO contra-angle handpiece The rotary drive movement is converted into a clockwisecounterclockwise movement with the ENO L contra-angle handpiece. 3.3 Structure of T1 LSSI ontra-angle handpiece Instrument head (in this case: standard) Push button ooling spray outlet E F E Opening of chuck system Light aperture F olor coding for gear ratio Straight handpiece Opening for the clamping system ooling spray outlet Light aperture enter part of handpiece
9 Sirona ental Systems GmbH Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE 3 Technical description 3.4 Structure of T1 LINE 3.4 Structure of T1 LINE ontra-angle handpiece Instrument head Push button ooling spray outlet E F G E Opening of chuck system Light aperture F olor coding for gear ratio G ISOslider Straight handpiece Opening for the clamping system ooling spray outlet Light aperture E enter part of handpiece E ISOslider 3.5 Structure of T2 LINE ontra-angle handpiece Instrument head Push button ooling spray outlet E F G E Opening of chuck system Light aperture F olor coding for gear ratio G ISOslider Straight handpiece Opening of chuck system ooling spray outlet Light aperture E enter part of handpiece E ISOslider
10 3 Technical description Sirona ental Systems GmbH 3.6 Structure of T3 LINE Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE 3.6 Structure of T3 LINE ontra-angle handpiece E Instrument head Push button ooling spray outlet Opening of chuck system olor coding for gear ratio Straight handpiece Opening of chuck system enter part of handpiece 3.7 ssembly of the T4 LINE ssembly of the T4 LINE and Ultimate Kit ontra-angle handpiece Instrument head Push button Opening for the clamping system Straight handpiece Opening for the clamping system E E enter part of handpiece
11 Sirona ental Systems GmbH Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE 3 Technical description 3.8 Technical data 3.8 Technical data T1 LSSI+T1-4 LINE_US ontra-angle handpiece T1 LSSI S 200 L/ S 200 L mini S 40 L S 6 L S 1.6 L Transmission ratio (approx. specification) 1:5 1:1 6:1 24:1 olor coding for gear ratio Red lue green green Maximum motor speed in rpm Maximum operating speed in rpm lamping system FG Internal cooling media x x x x ack suction stop Light function x x x x pex measurement function Instrument coupling Sirona Sirona Sirona Sirona T1 LINE 200 L/ 40 L 6 L 1.6 L 200 L mini Transmission ratio (approx. specification) 1:5 1:1 6:1 24:1 olor coding for gear ratio Red lue green green Maximum motor speed in rpm Maximum operating speed in rpm ~ ~ ~ 6000 ~ 1600 lamping system FG Internal cooling media x x x x ack suction stop x x x x Light function x x x x pex measurement function Instrument coupling INTRmatic LUX INTRmatic LUX INTRmatic LUX INTRmatic LUX INTRmatic INTRmatic INTRmatic INTRmatic
12 3 Technical description Sirona ental Systems GmbH 3.8 Technical data Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE T2 LINE 200 L 40 L 6 L Transmission ratio (approx. specification) 1:5 1:1 6:1 olor coding for gear ratio Red lue green Maximum motor speed in rpm Maximum operating speed in rpm ~ ~ ~ 6000 lamping system FG Internal cooling media x x x ack suction stop x x x Light function x x x pex measurement function Instrument coupling INTRmatic LUX INTRmatic INTRmatic LUX INTRmatic INTRmatic LUX INTRmatic T3 LINE E 200 E 40 E 6 Transmission ratio (approx. specification) 1:5 1:1 6:1 olor coding for gear ratio Red lue green Maximum motor speed in rpm Maximum operating speed in rpm ~ ~ ~ 6000 lamping system FG Internal cooling media x x x ack suction stop x x x Light function pex measurement function Instrument coupling INTRmatic INTRmatic INTRmatic T4 LINE 40 Transmission ratio (approx. specification) ~ 1:1 olor coding for gear ratio - Maximum motor speed in rpm Maximum operating speed in rpm ~ lamping system Internal cooling media - ack suction stop - Light function - pex measurement function - Instrument coupling INTRmatic
13 Sirona ental Systems GmbH Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE 3 Technical description 3.8 Technical data Special contra-angle handpiece PROPHY EV 04 L/ ONENS ENO L ENO 6 L KM 1.6 L 11 L vailable contra-angle handpieces: T1 LSSI x x - x - x T1 LINE x x x x x - T3 LINE - x Transmission ratio 2.4: :1 24:1 (approx. specification) Maximum motor speed in rpm Maximum operating speed ~ in rpm Maximum cycles in rpm - ~ 6000 ~ ~ lamping system Snap-on & screw-in - - Ø shaft / adapter Ø 2.35 Motion Rotation Hub 0.4 mm / Strokes ±30 Rotation mm Internal cooling media x x ack suction stop x x - - x - Light function x x x x x x pex measuring function a x - Instrument coupling INTRmatic LUX INTRmatic LUX INTRmatic LUX INTRmatic LUX INTRmatic INTRmatic INTRmatic INTRmatic INTRmatic Sirona Sirona Sirona vailable for use in the US x x x - x - a. pex measuring function depending on the table top unit INTRmatic LUX Sirona
14 3 Technical description Sirona ental Systems GmbH 3.8 Technical data Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE Straight handpiece T1 LSSI S H40 L T1 LINE H 40 L T2 LINE H 40 L T3 LINE EH 40 T4 LINE H 40 Transmission ratio (approx. 1:1 1:1 1:1 1:1 1:1 specification) olor coding for gear ratio lue lue lue - - Maximum motor speed in rpm Maximum operating speed in rpm ~ ~ ~ ~ ~ lamping system /HP HP/ HP/ HP/ HP/ Internal cooling media x x x - - ack suction stop x x - - Light function x x x - - pex measurement function Instrument coupling Sirona INTRmatic LUX INTRmatic INTRmatic LUX INTRmatic INTRmatic INTRmatic instruments FG//HP urr instruments FG HP Shank diameter in mm Maximum total length in mm Maximum working diameter in mm Standard ISO ISO 2157 ISO ISO center _ Instrument Treatment center T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE Spray air pressure in bar 2.7 Spray water pressure in bar 2.0 Maximum water temperature in 40 Recommended water content in spray in ml/min > This product bears the E marking in accordance with the provisions of ouncil irective 93/42/EE of June 14, 1993 concerning medical devices
15 Sirona ental Systems GmbH Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE 4 Preparation 4.1 Initial start-up and longer breaks in use 4 Preparation 4.1 Initial start-up and longer breaks in use Instrument Sterilize the instrument and accessories prior to startup. lean and maintain the instrument after longer breaks in use. 4.2 Prior to starting the work day Purge the water and air channels for seconds. 4.3 efore each patient Preparation _ Instrument 1. Purge the water and air channels for 30 seconds. 2. UTION! Keep the motor running. Insert the instrument [ 16]. 3. Insert the burr instrument [ 17]. 4. Set a sufficient amount of cooling water (> 50 ml/min). 5. Use filtered water only (< 50 µm). 6. heck the nozzles for blockages and lime deposits, for example, and clean the nozzles if necessary [ 27]. Overheating at the preparation site UTION! Insufficient cooling leads to overheating of the preparation site and damage to the tooth substance. Ensure that the water content is > 50ml/min
16 5 Operation Sirona ental Systems GmbH 5.1 Replacing the instrument Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE 5 Operation Fatigue fracture NOTIE! Use only faultless files in order to prevent fatigue fractures of the files as far as possible. Use only undamaged burrs NOTIE! Use only burrs and diamond polishers that are sharp and undamaged. Use clean burrs and diamond polishers to avoid dirt in the clamping system. lamping the burr _ instrument UTION! loose or partially removed burr instrument can come loose from the head or break off. Risk of injury! Therefore the instrument must only be used when the burr instrument is securely clamped at least 10 mm deep. Only operate when the clamping system is closed UTION! The handpiece must only be operated with the clamping system closed. Overheating at the preparation site UTION! Insufficient cooling leads to overheating of the preparation site and damage to the tooth substance. Ensure that the water content is > 50ml/min. Zurückziehen der Wange _ Instrument UTION! o not pull the patient's cheek back with the contra-angle handpiece while the motor is running. This would actuate the pushbutton, thus creating a risk of burning the patient's oral mucosa. Red contra-angle handpiece UTION! lways operate the contra-angle handpieces with cooling spray when marked with a red dot! Observing manufacturer documentation IMPORTNT: For application details and operating data of the different preparation tools, please refer to the information provided by the manufacturer. 5.1 Replacing the instrument Motor at standstill UTION! The instrument should only be fitted or removed when the motor is at standstill. ttaching the LINE instrument with ISO slider The motor is at a standstill. 1. Insert the instrument until it snaps into place. 2. When using a motor with a light groove (): turn the instrument until the ISO slider clicks into place. the LSSI instrument ttaching the LSSI instrument T1 LSSI The motor has come to a stop. 1. Insert the instrument until it snaps into place. 2. Rotate the instrument until it clicks into place. Removing the instrument The motor is at a standstill. etach the instrument. o not pull on the supply hose while doing this
17 Sirona ental Systems GmbH Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE 5 Operation 5.2 Inserting and removing burr instruments 5.2 Inserting and removing burr instruments Free movement of the pushbutton IMPORTNT: heck the push button to make sure it moves freely! Use only undamaged burrs NOTIE! Use only burrs and diamond polishers that are sharp and undamaged. Use clean burrs and diamond polishers to avoid dirt in the clamping system. lamping the burr _ instrument UTION! loose or partially removed burr instrument can come loose from the head or break off. Risk of injury! Therefore the instrument must only be used when the burr instrument is securely clamped at least 10 mm deep. Only operate when the clamping system is closed UTION! The handpiece must only be operated with the clamping system closed. Inserting the friction grip burr instrument ttach and Remove FG The motor is at a standstill. 1. Press the button and slide the burr instrument in until it reaches the stop. 2. Pull on the burr instrument to check that it is firmly attached. Removing the friction grip burr instrument The burr instrument must not be moving. Press the button and remove the burr instrument. Use W for contra-angle handpiece Inserting the contra-angle handpiece burr instrument The motor is at a standstill. 1. Insert the burr instrument without pushing the button. 2. Turn the burr instrument back and forth gently until it snaps into place. 3. Pull and turn the burr instrument to check that it is firmly seated. Removing the contra-angle handpiece burr instrument The burr instrument must not be moving. Press the button and remove the burr instrument. Straight handpiece Inserting the straight handpiece burr instrument E F LINE / LSSI The motor has come to a stop. 1. Turn the center part of the handpiece in the direction of the arrow () up to the stop. 2. When using the contra-angle handpiece burr instrument (): insert the pin () into the handpiece, with the slotted end first. The pin compensates for the difference in length between straight and contraangle handpiece burr instruments. 3. Insert the burr instrument as far as it will go. 4. lamp the burr instrument by turning the center part of the handpiece in direction () up to the stop. When the two marks (E) are located opposite each other, the burr instrument is clamped. When using handpiece burr instruments with detached shaft: ensure that the detached shaft is not lying against the chuck opening (F). 5. Then pull and turn the burr instrument to check that it is firmly seated
18 5 Operation Sirona ental Systems GmbH 5.3 Inserting and removing an EV/G5 instrument Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE Removing the pin 1. Screw in the supplied tool (). 2. Open the clamping system. 3. Pull out the pin. 5.3 Inserting and removing an EV/G5 instrument Inserting an EV/G5 instrument 1. Insert the instrument. In doing so, rotate the instrument from one side to the other. 2. Snap the instrument into the first or second detent position (/). The instrument can be freely rotated in the first detent position (). In the second detent position (), 10 fixed angle positions can be selected. Removing an EV/G5 instrument Pull the instrument out by hand. If this proves difficult or the instrument breaks: use the ejector () included in the scope of supply. 5.4 Inserting and removing a prophylaxis instrument T1 LSSI PROPHY IMPORTNT: Operate the PROPHY contra-angle handpiece only with clockwise rotation. IMPORTNT: Only use prophylaxis instruments which comply with the ISO standard. The PROPHY contra-angle handpiece is protected by a special seal system against penetration of polishing paste. Inserting a prophylaxis instrument T1 LSSI 1. Pull the contra-angle handpiece off of the motor. 2. Insert the PROPHY spray adapter () into the contra-angle handpiece until it snaps into place. Hold the driver securely in the contra-angle handpiece with the PROPHY spray adapter. 3. Screw the screw plug ()/screw-in adapter () firmly into the head of the contra-angle handpiece. 4. If you use a screw-in adapter, let the tool () snap onto it. 5. heck that the prophylaxis instrument is securely positioned
19 Sirona ental Systems GmbH Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE 5 Operation 5.4 Inserting and removing a prophylaxis instrument Removing a prophylaxis instrument T1 LSSI 1. Pull the contra-angle handpiece off of the motor. 2. Insert the PROPHY spray adapter into the contra-angle handpiece until it snaps into place. Hold the driver securely in the contra-angle handpiece with the PROPHY spray adapter. 3. If you use a snap-on cap, pull the tool from the screw-in adapter. 4. Unscrew the screw plug/screw-in adapter T1 LINE PROPHY IMPORTNT: Operate the PROPHY contra-angle handpiece only with clockwise rotation. IMPORTNT: Only use prophylaxis instruments which comply with the ISO standard. The PROPHY contra-angle handpiece is protected by a special seal system against penetration of polishing paste. Inserting a prophylaxis instrument T1 LINE 1. Pull the contra-angle handpiece off of the motor. 2. Hold the driver securely in the contra-angle handpiece with the PROPHY keybar (). 3. Screw the screw plug ()/screw-in adapter () firmly into the head of the contra-angle handpiece. 4. If you use a screw-in adapter, let the tool () snap onto it. 5. heck that the prophylaxis instrument is securely positioned. Removing a prophylaxis instrument T1 LINE 1. Pull the contra-angle handpiece off of the motor. 2. Hold the driver securely in the contra-angle handpiece with the PROPHY keybar. 3. If you use a snap-on cap, pull the tool from the screw-in adapter. 4. Unscrew the screw plug/screw-in adapter T4 LINE H 40 The handpiece fits disposable prophylaxis heads (e.g., oriot type made of plastic). UTION! The handpiece must only be operated with the clamping system closed. IMPORTNT: Reduce the maximum operating speed of the handpiece according to the manufacturer s specifications on the dental unit
20 5 Operation Sirona ental Systems GmbH 5.5 Inserting and removing an amalgam condenser instrument Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 Inserting a prophylaxis instrument Procedure inserting The motor is at a standstill. 1. Turn the center part of the handpiece in the direction of the arrow () until it reaches the stop. 2. Insert the drive shaft of the disposable prophylaxis head into the handpiece until it reaches the stop. 3. lose the clamping system by turning the center part of the handpiece in the direction of the arrow () until it reaches the stop. When the screw and the marking () are lined up with one another, the disposable prophylaxis head is clamped. Removing a prophylaxis instrument Procedure removing The motor is at a standstill. 1. Open the clamping system. 2. Remove the disposable prophylaxis head. 5.5 Inserting and removing an amalgam condenser instrument The treatment head has a spring chuck. Inserting an amalgam condenser instrument 1. Snap the instrument in place behind the retaining clip. 2. heck whether the instrument is firmly seated by pulling it. Removing an amalgam condenser instrument Pull out the instrument. Ø 3,6 4 mm Ø 2,35 mm 5.6 Inserting and removing ENO instruments ENO L ttaching and detaching the spray clip Inserting ENO instruments The motor is at a standstill. 1. When using the contra-angle handpiece instrument: press the pushbutton and insert the adapter () into the head as far as it will go. 2. While pressing and holding down the pushbutton, insert the ENO instrument as far as it will go. 3. Then pull and turn the ENO instrument to check that it is firmly seated. Removing ENO instruments The motor is at a standstill. 1. Pull the ENO instrument out while pressing and holding down the pushbutton. 2. When using the contra-angle handpiece instrument: press down the pushbutton and pull out the adapter by its collar ()
21 Sirona ental Systems GmbH Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE 5 Operation 5.7 Recommendation for the treatment procedure ttaching the spray clip for rinsing and disinfecting The spray water supply at the motor or treatment center is turned off. 1. ttach the silicone hose () to the spray clip (). 2. Plug the spray clip into the contra-angle handpiece. Removing the spray clip for rinsing and disinfecting Remove the spray clip from the contra-angle handpiece ENO 6 L Inserting ENO instruments The motor is at a standstill. 1. Insert the file by gently rotating it until it snaps into place. In doing so, do not press the pushbutton. 2. Then pull and turn the file to check that it is firmly seated. Removing ENO instrument The motor is at a standstill. Remove it while pressing and holding down the pushbutton. 5.7 Recommendation for the treatment procedure Fatigue fracture NOTIE! Use only faultless files in order to prevent fatigue fractures of the files as far as possible. Please observe the operating instructions pertaining to the apex locator being used. The different file systems require different working techniques. For this reason, please always observe the information provided by the file manufacturer. Work without exerting any pressure on the file. The apex locator function is used to support the root canal preparation process in combination with SIROEndo. The number of X-rays can be reduced with ENO 6 L. However, you must always take at least one X-ray to determine the depth for preparatory work. clinical evaluation including knowledge of the anatomy of root canals is important for the interpretation of the results. If the file seizes in the tooth: remove the file by gently pulling it toward the coronal end. If this is not possible, switch the drive to counterclockwise rotation and pull the file out of the channel. IMPORTNT: heck the file afterwards for damage or deformation (untwisting) and replace it, where necessary. Please observe the information provided by the file manufacturer
22 5 Operation Sirona ental Systems GmbH 5.8 Mounting and removing the insulating sleeve Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE! Wear islolated gloves When performing the PEX measurement, wear appropriate insulated gloves. We recommend performing the treatment with a cofferdam, while using an insulating sleeve. This will prevent inaccurate measurements caused by undesired leakage currents. uring the measurement, the instrument must not come into contact with the patient's mucosa, metallic tooth restorations, or the mucosal electrode. 5.8 Mounting and removing the insulating sleeve NOTIE! Insulating sleeves are only used once. hange the insulating sleeve after each patient. Fitting an insulating sleeve Mounting _ File You have sterilized the insulating sleeve. The motor is at a standstill. file is not clamped in place. 1. Twist the insulating sleeve carefully this way and that and pull the insulating sleeve fully over the instrument. 2. ttach the file. Removing an insulating sleeve Removing _ File The motor is at a standstill. 1. Remove the file. 2. Remove the insulating sleeve. 3. ispose of the insulating sleeve [ 32]. 5.9 Inserting and removing a Kirschner-Meyer instrument Inserting a Kirschner-Meyer instrument The motor is at a standstill. 1. Slide the deflection disk () onto the shaft of the burr instrument. The deflection disk prevents the air coming out of the head from entering the open wound. 2. Insert the burr instrument without pushing the button. 3. Turn the burr instrument back and forth gently until it snaps into place. 4. Push the deflection disk up to the head. 5. Then pull and turn the burr instrument to check that it is firmly seated. Removing a Kirschner-Meyer instrument The burr instrument must not be moving. Press the button and remove the burr instrument
23 Sirona ental Systems GmbH Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE 5 Operation 5.10 onnect and remove external spray onnecting the hose for the Nal solution ttach the silicone hose () to the spray tube () for the hollow burr. dditionally, you can cool the burr externally with Nal solution. E 1. Plug the spray clip () in [ 23]. 2. onnect the silicone hoses ( and E) using the distributor (), as shown in the illustration onnect and remove external spray onnect external spray 1. ttach the instrument to the motor. 2. ttach the silicone hose () to the small tube on the spray clip () and motor. 3. ttach the spray clip to the instrument. Remove external spray 1. etach the silicone hose from the motor. 2. Remove the spray clip from the instrument. 3. Flush the spray clip and silicone hose with clear water Plugging in and removing the spray clip for NaI application Plugging in the spray clip The spray water supply at the motor or treatment center is turned off. 1. Plug the silicone hose () into the tubule on the spray clip for saline solutions (/). 2. Plug the spray clip into the instrument. Tip: Use the silicone disks (), to hold back the cooling air emitted from the instrument from the preparation site and to direct it away laterally. Removing the spray clip 1. Remove the spray clip from the instrument. 2. Flush out the spray clip and silicone hose with clear water
24 6 Follow-up Sirona ental Systems GmbH 6.1 fter each treatment session Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE 6 Follow-up 6.1 fter each treatment session Immediately after treatment NOTIE! ondition immediately, or at the latest, one hour after treatment. Using the T1 spray NOTIE! Only use Sirona T1 spray. Instruments _ burr instrument The burr instrument must not be moving. Wear appropriate protective clothing. 1. Purge the water and air channels on the treatment center for 30 seconds. 2. Remove the burr instrument with tweezers. 3. Pre-disinfect directly at the treatment center [ 25]. 4. etach the instrument from the motor. 5. Transport the instrument to the hygiene room in a suitable transport container. 6. onduct automatic conditioning [ 25]. Manual conditioning [ 26] is possible in exceptional cases if the national/local regulations are followed. 7. pply spray to the instrument [ 26]. 8. Sterilize the instrument and accessories [ 28]. 6.2 t the end of the work day Instrument pply spray to the instrument [ 26]. Remove the motor at night NOTIE! o not leave any instruments on the motor overnight, in order to prevent oil from leaking into the electric motor. Never lubricate the electric motor
25 Sirona ental Systems GmbH Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE 7 onditioning 7.1 onduct pre-disinfection 7 onditioning 7.1 onduct pre-disinfection Predisinfection _ Product name _ Variable Wear appropriate protective clothing. ll disinfectants must be approved in your country and have proven bactericidal, fungicidal and virucidal properties. Only use disinfectants with no protein-fixing properties. 1. Spray the surface with disinfectant. 2. Wipe the disinfectant away with a cloth. For further processing, T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE should be dry and free of residue. isinfectants in US und anada In the US and anada, for example, you can use: VIIE VIWIPES Please observe the manufacturer's instructions for using instrument disinfectants. 7.2 utomated cleaning and disinfecting with cleaning and disinfection equipment Instrument The instrument can also be cleaned and disinfected in a suitable piece of cleaning and disinfection equipment. leaning and disinfection equipment The cleaning and disinfection equipment used must be approved by its manufacturer for the cleaning and disinfection of dental instruments and comply with EN ISO (e.g. 95 (203 F) and 10 min. holding time). For further details, refer to the operating instructions supplied with the unit. Kontrolle _ Instrument The instrument is conditioned with a cleaning and disinfection device. 1. heck whether the instrument is clean after conditioning under good lighting (min. 500 lux) and color rendering index (min. 80 Ra). 2. If it is still dirty, repeat the process. For further conditioning, the instrument should be dry and free of residue. 3. low the instrument out with max. 3 bar. 4. Manual care of mechanical parts [ 26]. 5. Manual care of the push button chuck [ 27]. 6. Pack the instrument in packaging material suitable for sterilization and storage. e.g. paper/plastic composite packaging. 7. Sterilize the instrument [ 28]
26 7 onditioning Sirona ental Systems GmbH 7.3 Manual cleaning and disinfection Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE 7.3 Manual cleaning and disinfection Immediately after treatment NOTIE! ondition immediately, or at the latest, one hour after treatment. NOTIE! Never clean in an ultrasound bath! NOTIE! Never immerse in disinfectants! Using the T1 spray NOTIE! Only use Sirona T1 spray. Use soft brush IMPORTNT: Use a soft, clean, and disinfected brush for cleaning. Procedure _ Instrument with integrated spray Wear appropriate protective clothing. ll disinfectants must be approved in your country and have proven bactericidal, fungicidal and virucidal properties. Only use disinfectants with no protein-fixing properties. 1. rush the instrument under running water (< 38, < 100 F, at least drinking water quality) and good lighting (min. 500 lux) and color rendering index (min. 80 Ra) until no more dirt can be seen, for at least 10 seconds. 2. Flush the drive channels with spray. 3. lean and disinfect spray channels with suitable agents and adapters according to manufacturer's instructions. 4. low spray channels with suitable adapters out with bar until no more moisture displaces, but at least 10 seconds. 5. onduct thermal disinfection or unwrapped steam sterilization. 6. Maintain mechanical parts manually [ 26]. 7. Maintain the push button chuck manually [ 27]. 8. Pack the instrument in packaging material suitable for sterilization and storage. e.g. paper/plastic composite packaging. 9. Sterilize the adapter [ 28]. 7.4 Manual maintenance Maintenance of mechanical parts Intervals aily at noon and in the evening t least every noon and evening Prior to each sterilization fter every thermal disinfection without integrated maintenance accessories Required accessories Spray adapter, T1 LSSI, T1-4 LINE E F O-ring for spray adapter Spray adapter Spray adapter, LSSI Spray adapter, PROPHY lack nozzle insert T1 spray Using the T1 spray NOTIE! Only use Sirona T1 spray
27 Sirona ental Systems GmbH Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE 7 onditioning 7.4 Manual maintenance Process Maintenance _ Instrument The spray adapter is disinfected. The O-ring on the spray adapter is intact. 1. Fit the spray adapter onto the nozzle of the spray can. 2. Insert the instrument until it snaps into place and hold it. 3. Spray the instrument for 1-2 seconds. IMPORTNT: Hold the spray can upright. 4. Wipe any spray that comes out with a disinfection cloth. 5. Repeat the process until the spray is clear are of the push button chuck New Sirona Use T1 spray on the push button chuck to remove deposits and ensure proper functioning of the clamping system. Interval t least once a week Required accessories T1 spray lack nozzle insert T1 spray Using the T1 spray NOTIE! Only use Sirona T1 spray. Procedure Vorgehensweise _ Winkelstück The instrument is clean and disinfected. 1. Press the contra-angle handpiece head with the chuck firmly against the spray can nozzle. 2. Spray the chuck for 1-2 seconds. IMPORTNT: Hold the spray can upright. 3. Wipe any spray that comes out with a disinfection cloth Maintenance of cooling spray nozzles! Hard tap water If your tap water is very hard, lime deposits may constrict or completely block the cooling spray nozzles. leaning the nozzle _ Instrument 1. arefully clean the nozzle openings by running a cleaning wire through them. 2. Let the instrument run briefly with cooling spray
28 7 onditioning Sirona ental Systems GmbH 7.5 Sterilizing Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE 7.5 Sterilizing _ US Intervals: Prior to initial operation Prior to every other use Process ction steps_instruments The instrument is clean and disinfected. Instrument maintenance is complete. If necessary, the instrument can be sterilized in packaging suitable for sterilization and storage: paper/plastic composite packaging according to ISO Unit pressure in bar and psi_us Sterilize the instrument in the steam sterilizer with saturated water vapor. Temperature: 135 (275 F) Overpressure: 2.13 bar (30.89psi) Holding time: 10 minutes rying time: 30 minutes PROFESSIONL _ US Gravity displacement steam sterilizer are permitted. NOTIE! o not exceed 140 (284 F), even during the drying phase. sterilizing - heading fter sterilizing Subsequent steps_instruments 1. Remove the instrument from the steam sterilizer immediately. UTION! The instrument is hot. Risk of burns! NOTIE! o not attempt to accelerate the cooling process by immersing the instrument in cold water. This can damage your instrument. 2. Store all instruments so that they are protected from contamination. 3. Sterilize again once the storage period has elapsed
29 Sirona ental Systems GmbH Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE 8 Maintenance 8.1 Testing the FG clamping system 8 Maintenance Replacing elastomers Elastomers, e.g. O-rings, must be replaced depending on their degree of wear. Tool holding system For safety and technical reasons, check the clamping system of the contra-angle and straight handpiece burr instruments on an annual basis. Friction grip heck the clamping system of friction grip burr instruments on a monthly basis [ 29]. 8.1 Testing the FG clamping system Interval Test the FG clamping system at least once a month. Required accessories huck tester Process The expiry date of the chuck tester () has not elapsed. 1. Insert the chuck tester into the FG clamping system [ 17]. 2. Tighten the chuck tester until the marking ring appears (withdrawal force: 22 N) oes the chuck tester slide out of the chuck before the marking ring appears? UTION! The chuck is defective and the secure fit of the burr instrument is not guaranteed. This may cause injury! Workshop _ Sirona 1. o not use the product. 2. Have the clamping system replaced by a workshop authorized by Sirona. Tip: Record the time and result of the check for your own information. 8.2 Replacing the spray tube on the T1 LSSI KM 1.6 L Removing the spray tube 1. isengage the spray tube () from the bracket (). 2. Remove the spray tube from the instrument head. Inserting the spray tube 1. Plug the spray tube into the instrument head. 2. Engage the spray tube in the bracket
30 9 Spare parts and consumables Sirona ental Systems GmbH Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE 9 Spare parts and consumables ccessories + approved accessories Use only original Sirona parts or parts approved by Sirona. T1 LSSI, T1-4 LINE REF REF T1 spray (6 x 250 ml cans) huck tester leaning wire for spray nozzles O-ring 8 x Pin for contra-angle handpiece burr instrument Tool for pin (contra-angle handpiece burr instrument) Spray adapter O-ring for spray adapter Spray adapter, PROPHY Spray adapter T1 LSSI Ejector for EV/G5 instrument ENO adapter for contra-angle handpiece instruments Insulating sleeve for Endo 6 L (5 pcs.) Screw-in adapter, prophylaxis (snap-on) Nal coupling for silicone hoses Nal silicone hose, thin, 200 mm long, pcs. Nal silicone hose, thick, 1.8 m long Spray clip for contra-angle handpiece Nal spray clip H for straight handpiece Nal spray clip for contra-angle handpiece Silicone disk for contra-angle handpiece, dia mm Silicone disk for contra-angle handpiece, dia. 1.6 mm
31 Sirona ental Systems GmbH Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE 10 Storage and transport conditions 10 Storage and transport conditions Protect from moisture Sensitive contents Relative humidity ir pressure Temperature kpa fter a severe change in temperature, allow sufficient time for acclimatization
32 11 isposal Sirona ental Systems GmbH Operating instructions T1 LSSI / T1 LINE / T2 LINE / T3 LINE / T4 LINE 11 isposal isinfected ccording to current information, the product does not contain any substances that are hazardous to the environment. isinfect the product prior to disposal. Observe the applicable disposal regulations for your area
33
34 té=êéëéêîé=íüé=êáöüí=íç=ã~âé=~åó=~äíéê~íáçåë=ïüáåü=ã~ó=äé=êéèìáêéç=çìé=íç=íéåüåáå~ä=áãéêçîéãéåíëk «=páêçå~=aéåí~ä=póëíéãë=dãäe=omnr péê~åüéw ÉåÖäáëÅÜ=ErpF mêáåíéç=áå=déêã~åó aprvtkomnkmqkmnkop MRKOMNR ûkjkêkw= MMM=MMM páêçå~=aéåí~ä=póëíéãë=dãäe c~äêáâëíê~ É=PN ajsqsor=_éåëüéáã= déêã~åó ïïïkëáêçå~kåçã áå=íüé=rp^w páêçå~=aéåí~ä=póëíéãë=ii` QUPR=páêçå~=aêáîÉI=pìáíÉ=NMM `Ü~êäçííÉI=k`=OUOTP rp^ lêçéê=kç SR=QR=QRU=aPRVT
T1 LINE / T1 CLASSIC
kéï=~ë=çñw== MRKOMNO T1 LINE / T1 LSSI lééê~íáåö=fåëíêìåíáçåë båöäáëü Sirona ental Systems GmbH Table of contents 1 efore you begin... 3 1.1 Scope of this operating manual 3 1.2 Structure of the document
More information6390830.book Seite 1 Freitag, 22. Juni 2012 12:43 12. qn=ifkb=l=qo=ifkb. Operating Instructions. båöäáëü. lééê~íáåö=áåëíêìåíáçåë
6390830.book Seite 1 Freitag, 22. Juni 2012 12:43 12 qn=ifkb=l=qo=ifkb Operating Instructions båöäáëü lééê~íáåö=áåëíêìåíáçåë 6390830.book Seite 2 Freitag, 22. Juni 2012 12:43 12 Table of contents 1 Before
More informationqn=ifkb=l=qo=ifkb=l=qp=ifkb
6390830.book Seite 1 Dienstag, 7. August 2012 3:39 15 qn=ifkb=l=qo=ifkb=l=qp=ifkb Operating Instructions båöäáëü lééê~íáåö=áåëíêìåíáçåë 6390830.book Seite 2 Dienstag, 7. August 2012 3:39 15 6390830.book
More information4163908.book Seite 1 Mittwoch, 29. August 2007 3:06 15. qn=ifkb. píê~áöüí=~åç=åçåíê~j~åöäé=ü~åçéáéåéë. båöäáëü. lééê~íáåö=fåëíêìåíáçåë
4163908.book Seite 1 Mittwoch, 29. August 2007 3:06 15 qn=ifkb píê~áöüí=~åç=åçåíê~j~åöäé=ü~åçéáéåéë båöäáëü lééê~íáåö=fåëíêìåíáçåë 4163908.book Seite 2 Mittwoch, 29. August 2007 3:06 15 We reserve the
More informationqn=l=qo=l=qp=üáöüëéééç=ü~åçéáéåé pk=y=smm=mmm Ñçê=páêçå~I=h~sçI=tCe=~åÇ=kph=j~ÅÜiáíÉ=ÅçååÉÅíáçå
kéï=~ë=çñw== MOKOMNP qn=l=qo=l=qp=üáöüëéééç=ü~åçéáéåé pk=y=smm=mmm Ñçê=páêçå~I=h~sçI=tCe=~åÇ=kph=j~ÅÜiáíÉ=ÅçååÉÅíáçå lééê~íáåö=fåëíêìåíáçåë båöäáëü Operating Instructions / XY turbine / 01 for Sirona,
More informationTotally lightweight, totally flexible, totally titanium.
CAD/CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS T1 LINE THE LIGHTWEIGHT TITANIUM INSTRUMENTS Totally lightweight, totally flexible, totally titanium. T h e D e n t a l C o
More informationT1 LINE. Handpieces. T1 LINE supreme ergonomics in titanium.
T1 LINE Handpieces T1 LINE supreme ergonomics in titanium. > To be quite frank, flexibility is what I m aiming at in my dental practice. Now the choice is easy: the Sirona T1 LINE handpiece range.< Andrew
More informationTotally lightweight, totally flexible, totally titanium.
CAD/CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS CAD/CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS SIRONA UNIQUE WORLDWIDE SYSTEMS EXPERTISE IN
More informationWe make a point of ensuring safety.
CAD/CAM SYSTEMS INSTRUMENTES HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS INSTRUMENTS FOR EFFICIENT ROOT CANAL TREATMENT We make a point of ensuring safety. T h e D e n t a l C o m p a n y ENDODONTIC
More informationVolkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)
17 Engine-Lubrication system (Page GR-17) Lubrication system components, removing and installing Oil pan, removing and installing Oil pressure and oil pressure switch, checking Dynamic oil pressure warning
More informationPOSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT
POSEION 2-29, 2-25 & 2-22 POSEION 2-29, 2-25 & 2-22 XT Repair Manual Index A. Safety precautions 3 B. Technical data 4 C. Structure 5-6. Service / Repair 7-23 E. Tools 24 F. Function 25-26 G. Electric
More informationM A N U A L 13-10-05
Documentation The following information sheets illustrate the description below: 12-WW01-4G-E Sectional view of the lance with main dimensions 12-W101-6G-E Sectional view of the head of the lance with
More informationHandpieces. T1 CLASSIC ergonomic perfection in titanium.
Handpieces ergonomic perfection in titanium. > I m used to working with only the very best equipment. Now the choice is easy: made by Sirona. < David Richards (49), dentist state-of-the-art handpieces
More informationFleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET
Fleck 4650 Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION AND START-UP PROCEDURE...1 CONTROL VALVE DRIVE ASSEMBLY...2 CONTROL DRIVE ASSEMBLY FOR CLOCK...3 BYPASS VALVE ASSEMBLY...4
More informationTool Holder Catalog INDEX ABC VDI 25 LL3602.30051-10.04.2014. 0414/Rö
Tool Holder Catalog INDEX ABC VDI 25 LL3602.30051-10.04.2014 0414/Rö Disclaimer The illustrations in this documents may deviate from the delivered product. We reserve the right to make changes due to errors
More informationCooling system components, removing and installing
Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
More informationTHREE CLASSES, ONE CLAIM: ONLY THE BEST INTO YOUR HANDS.
SIRONA INSTRUMENTS PREMIUM, COMFORT AND ECONOMY THREE CLASSES, ONE CLAIM: ONLY THE BEST INTO YOUR HANDS. SIRONA.COM 02 I 03 SIRONA INSTRU- MENTS UNIQUE IN EVERY CLASS. As a dental surgeon, you know good
More informationone claim: only the best into your hands.
Always at THE Forefront of Innovation! As global innovation leader for dental equipment, we continuously invest in re search and thus in the future of modern dentistry. By networking digital technologies
More informationVolkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)
17 Engine-Lubrication (Page GR-17) Lubrication system components, removing and installing Oil filter housing, disassembling and assembling Oil pan, removing and installing Oil pressure and oil pressure
More informationTHREE CLASSES, ONE CLAIM: ONLY THE BEST INTO YOUR HANDS.
SIRONA INSTRUMENTS PREMIUM, COMFORT AND ECONOMY THREE CLASSES, ONE CLAIM: ONLY THE BEST INTO YOUR HANDS. SIRONA.COM Made in Germany Titan, the exclusive material As the only manufacturer in the dental
More informationThis instruction is valid for all ACD pump models shown on page 2
Screw pumps ACD Maintenance and Service Instruction This instruction is valid for all ACD pump models shown on page 2 Contents Page List of components 2 Exploded view/ordering code 3 Service intervals
More informationHYLA NST Cleaning System
Owner s Manual HYLA NST Cleaning System The HYLA NST Cleaning System aspirates and cleans the air through a waterbased filtration process. The system is intended for household use only. Applications: Usual
More informationSunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
More informationReasons for reissue are provided in Section 6, REVISION SUMMARY.
Reasons for reissue are provided in Section 6, REVISION SUMMARY. The FRONT OF TOOL has the AMP marking on the link. The BACK OF TOOL (Wire Side), into which the wire is inserted, has the wire size marked
More informationCappController Pipette Controller. Operation Manual Version: 1.2. www.capp.dk
CappController Pipette Controller Operation Manual Version: 1.2 www.capp.dk skal vises her. Table of Content 1. Safety Precautions... 1 2. General Description... 2 3. Getting Started... 4 3.1. Recharging
More informationFailure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
More informationCooling system components, removing and installing
Engine BHW Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! When doing any repair work, especially in the engine compartment,
More informationPBX Series Quick Fit Connector Bimetallic Steam Traps
6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
More informationThermostatic bar showers. Troubleshooting and maintenance
Thermostatic bar showers Troubleshooting and maintenance General Fault Diagnosis Outlet too cold Outlet too hot - Hot water supply must be 10ºC higher than desired mixed outlet for the mixer to operate
More informationTool Holder Catalog TRAUB TNX 65/42 VDI 30 HSK 40 142856-21.02.2014. 0214/Rö
Tool Holder Catalog TRAUB TNX 65/42 VDI 30 HSK 40 142856-21.02.2014 0214/Rö Disclaimer The illustrations in this documents may deviate from the delivered product. We reserve the right to make changes due
More informationTrouble Shooting. Pump
Trouble Shooting Pump Trouble Possible Cause Remedy Oil leaking in the area of water pump crankshaft Worn crankshaft seal, bad bearing, grooved shaft, or failure of retainer o-ring. Excessive play on crankshaft
More informationChar-Lynn Hydraulic Motor. Repair Information. 10 000 Series. October, 1997
Char-Lynn Hydraulic Motor October, 1997 Repair Information Geroler Motor Two Speed 001 27 Retainer inside bore of valve plate bearingless motors only 4 15 16 3 6 35 Parts Drawing 25 2 2 1 19 17 36 40 47
More informationOperating Instructions Drill rig DRU160
Operating Instructions Drill rig DRU160 Index 000 / 001 Original operating instructions 10988825 en / 20.10.2009 Congratulations! With a Hydrostress unit from TYROLIT you have chosen a tried and tested
More informationPet hair clipper. Model 96822. Diagrams within this manual may not be drawn proportionally.
Pet hair clipper Model 96822 Cleaning And Operation Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the
More informationTERMINATION EQUIPMENT INSTRUCTION MANUAL TELE-PIERCE P/N 356-246
TERMINATION EQUIPMENT INSTRUCTION MANUAL TELE-PIERCE P/N 356-246 OPERATION AND SERVICE INSTRUCTIONS AMPHENOL 157 SERIES TELE-PIERCE MULTI-WIRE TERMINATION TOOL 356-246 AMPHENOL TERMINATION SYSTEMS 1830
More informationOperating instructions. SCORP 220 Plus SCORP 360. Pipe Cutter. Code 790 014 762 Machine-no.:
precision. power. simplicity. Operating instructions Pipe Cutter SCORP 220 Plus SCORP 360 Code 790 014 762 Machine-no.: All rights reserved, in particular the rights of duplication and distribution as
More informationNational Optical & Scientific Instruments Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104
National Optical & Scientific Instruments Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104 INSTRUCTIONS FOR MODELS 106, 106-L 107, 107-L 108, 108-L 109-L ELEMENTARY
More informationIMPORTANT SAFETY RULES TO FOLLOW
WARNING FLOOR & CARPET CLEANER Any piece of equipment can be dangerous if not operated properly. YOU are responsible for the safe operation of this equipment. The operator must carefully read and follow
More informationNational Optical & Scientific Instrument Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104
National Optical & Scientific Instrument Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104 INSTRUCTIONS FOR STEREOSCOPIC MICROSCOPES MODEL NUMBERS 400 400TL
More informationLUCCI AIRFUSION QUEST II CEILING FAN
LUCCI AIRFUSION QUEST II CEILING FAN WITH IR REMOTE INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 QUEST II IR
More information- 2 - IMPORTANT SAFETY REMINDERS
USER MANUAL IMPORTANT SAFETY REMINDERS This appliance should only be used for domestic cleaning, as described in this user guide. Please ensure that this guide is fully understood before operating the
More informationBATHROOM HEATER. User's Manual. Page 2...A515 Page 9...A716
BATHROOM HEATER User's Manual Page 2...A515 Page 9...A716 BATHROOM HEATER User's Manual A515 SAVE THESE INSTRUCTIONS AND READ ALL INSTRUCTIONS BEFORE USING THE HEATER. Dear customers, Thank you for selecting
More informationDIAMOND Retractable Rodding Robot Model SPRAYROD-R
2004-12-21 2 1 (23) DIAMOND Retractable Rodding Robot Model SPRAYROD-R 2004-12-21 2 2 (23) Table of contents 1 TECHNICAL DESCRIPTION...4 1.1 MAIN DETAILS...5 1.2 COMPONENTS DESCRIPTION...5 1.2.1 Pneumatic
More informationFailure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
More informationOperating instructions in the back. www.blackanddecker.co.uk PD1020L
Operating instructions in the back www.blackanddecker.co.uk PD1020L 2 ENGLISH (Original instructions) Intended use Your Black & Decker Dustbuster handheld vacuum cleaner has been designed for vacuum cleaning
More informationFUEL CELL CAR SCIENCE KIT ASSEMBLY GUIDE. Battery operation instructions:
FUEL CELL CAR SCIENCE KIT ASSEMBLY GUIDE Battery operation instructions: 1. The removing and inserting of batteries is to be conducted by the adults only. Unscrew the screw holding the battery pack s cover
More informationT-Series Precision Linear Actuators Installation and Service Manual DW110353GB-1018 - EDITION 5. www.thomsonlinear.com
T-Series Precision Linear Actuators Installation and Service Manual DW110353GB-1018 - EDITION 5 www.thomsonlinear.com Version History Edition Number Edition Date Reason for Revision 1 2004 First edition
More informationInstallation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet
More informationMilwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01
Milwaukee Milwaukee USER MANUAL PORTABLE DISSOLVED OXYGEN METER MODEL: SM600 Smart DO Meter Authorized Dealer: ISMIL600 11/01 PROBE PREPARATION: The meter is supplied with a 9V battery. Slide off the battery
More informationROTOR LOADER OWNER S MANUAL
ROTOR LOADER OWNER S MANUAL ROTOR LOADER OWNER S MANUAL WARNING IMPORTANT SAFETY INSTRUCTIONS AND GUIDELINES. Misuse of paintball equipment may cause serious injury or death. QUICK SET-UP GUIDE BATTERY
More informationOperating Instructions Bedienungsanleitung Mode d emploi
Operating Instructions Bedienungsanleitung Mode d emploi DW 400 www.bron-kobold.com Operating instructions DW 400 Before use Please read all the information contained in these operating instructions carefully.
More informationOil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
More informationMIST DECORATIVE LAMP WITH ESSENTIAL OIL DIFFUSER
EN MIST DECORATIVE LAMP WITH ESSENTIAL OIL DIFFUSER OPERATING INSTRUCTIONS Read the instructions carefully before operating the appliance or carrying out maintenance operations. Observe all the safety
More informationUSER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
More informationInstruction Manual. Image of SP-3015 & SP-3815. Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function
Important Safeguards READ ALL INSTRUCTIONS BEFORE USE. Instruction Manual Automatic Dispensing Hot Water Pot with Reboil Function Image of SP-3015 & SP-3815 SP-3015: 3.0L SP-3815: 3.8L SP-3017: 3.0L (Stainless
More informationHearing Direct.com. Operating instructions. Model HD 350
Hearing Direct.com Operating instructions Before use, please read these instructions to help you get the best out of your HearingDirect.com hearing aid Model HD 350 Introduction Hearing Direct.com Welcome
More informationTechnique Guide. Screw Removal Set. Instruments for removing Synthes screws.
Technique Guide Screw Removal Set. Instruments for removing Synthes screws. Table of Contents Introduction Screw Removal Set 2 Surgical Technique Preoperative Planning and Preparation 6 Removal of Intact
More informationDrive shaft, servicing
Volkswagen Passat B6 - Drive shaft, servicing Стр. 1 из 41 40-7 Drive shaft, servicing Drive shafts, overview I - Assembly overview: Drive axle with CV joint VL100 40-7, Drive axle with CV joint VL100,
More informationRoller Chain Coupling
Roller Chain Coupling Features 1. Simple structure A roller chain coupling consists of one duplex roller chain and two sprockets for a simplex chain. Handling is very simple as both the shafts (driving
More informationCoolflo Safe Touch Shower Mixing Valve ST20015CP
Coolflo Safe Touch Shower Mixing Valve ST20015CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept
More informationAKRAPOVIC SLIP-ON EXHAUST SYSTEM for the HONDA CB1000R
Installation instructions: *502131* AKRAPOVIC SLIP-ON EXHAUST SYSTEM for the HONDA CB1000R Congratulations on purchasing an Akrapovic exhaust system. Please read these installation instructions carefully.
More informationInstructions Manual AmazonBasics 12-Sheet Cross-Cut Paper / CD / Credit Card Shredder with Basket ASIN# B005QAQFFS. Customer Service 1-866-216-1072
Instructions Manual AmazonBasics 12-Sheet Cross-Cut Paper / CD / Credit Card Shredder with Basket ASIN# B005QAQFFS Customer Service 1-866-216-1072 Paper Shredder Instructions Manual Sheet Capacity 12 Sheets
More information233871 George master UK A06.indd 1 07/02/2012 10:25:11
233871 George master UK A06.indd 1 07/02/2012 10:25:11 Contents / Kits - A26A / A40A / A43 2 233871 George master UK A06.indd 2 07/02/2012 10:25:14 Wet - Assembling the machine for extraction use 3 233871
More informationDiscPlus DX195 and DX225 Air Disc Brakes
Revised 11-04 Technical Bulletin Revised 1 Technical 11-04 Bulletin DiscPlus DX195 and DX225 Air Disc Brakes Inspection, Installation and Diagnostics Air Disc Brake Inspection Intervals and Procedures
More informationJet Propulsion System
This repair manual is valid for the following jet pump variants: 0333_ 0 V3 007 3. 033_ 0 V 007 3. 0380_ 3 V 007 3. 0335_ 3 V 007 3. 033_ 66 V 008. 0338_ 66 V 008. Table of Contents Before you begin working
More informationBACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: 3402270 & 3402275 OPERATING & MAINTENANCE INSTRUCTIONS GC04/12
BACKPACK SPRAYERS MODEL NOS: KSP16 & KSP20 Part Nos: 3402270 & 3402275 OPERATING & MAINTENANCE INSTRUCTIONS GC04/12 INTRODUCTION Thank you for purchasing this CLARKE Sprayer, designed for use only with
More informationTRIMMING UNIT/DIAMOND MACHINE TST.13
TRIMMING UNIT/DIAMOND MACHINE TST.13 REFERENCE BOOK rel. 02.15 TRIMMING UNIT/DIAMOND MACHINE TST.13 REL. 02.15 ENGLISH LANGUAGE 1 MACHINE DESCRIPTION TST.13 was designed and built for processing methacrylate.
More informationSE-100-1, SE-200-1, SE-500-1, and SE-1000-1 AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81) 83 54 10 18 ventas@industrialmagza.
AIR CHAMP PRODUCTS User Manual SE BRAKE MODELS: SE-00-, SE-200-, SE-500-, and SE-000- (i) FORM NO. L-20084-E-040 In accordance with Nexen s established policy of constant product improvement, the specifications
More informationIMPACT SPRINKLER TROUBLESHOOTING GUIDE
RAIN USE AND OPERATION BIRD IMPACT SPRINKLER TROUBLESHOOTING GUIDE The diagrams below depict typical Rain Bird sprinklers with all available controls. Your particular model may have only some of these
More informationWARNING To reduce the risk of. READ ALL INSTRUCTIONS BEFORE USING. KEEP AWAY FROM WATER DANGER Any appliance is
IMPORTANT SAFETY INSTRUCTIONS When using electrical appliances, especially when children are present, basic safety precautions should always be followed, including the following: READ ALL INSTRUCTIONS
More informationORTHODONTIC MINI IMPLANTS Clinical procedure for positioning. Orthodontics and Implantology
ORTHODONTIC MINI IMPLANTS Clinical procedure for positioning Orthodontics and Implantology 2 All rights are reserved. Any reproduction of the present publication is prohibited in whole or in part and by
More informationUSER MANUAL. 10 GPM Small Single Line Cryogenic Coupling
JC Carter LLC LNG Couplings USER MANUAL 10 GPM Small Single Line Cryogenic Coupling Models 50E722 Nozzle and 50E721 Receptacle User s Manual and Installation Guide! Warning: Read the User s Manual and
More informationSuperEndo B&L-alpha II Cordless Heat Carrier Operation & Maintenance Instruction Manual
SuperEndo B&L-alpha II Cordless Heat Carrier Operation & Maintenance Instruction Manual PLEASE READ ALL INSTRUCTIONS PROVIDED FOR THIS DEVICE BEFORE USING IT. Caution: This product should only be used
More informationBoWex SD, SD1 and SD2 Operating-/Assembly Instructions
D-807 Rheine 0111 E 1 curved-tooth gear couplings are flexible shaft connections. They are able to compensate for shaft displacement caused by, as an example, inaccuracies in production, heat expansion,
More informationHydraulic control unit series 0086-372-01
Technical Product Information No. 1290 EN Hydraulic control unit series 0086-372-01 Contents Page About this Technical Product Information (TPI) 2 The ORTLINGHAUS numbering system 2 About the product 3
More informationReasons for reissue of this instruction sheet are provided in Section 5, REVISION SUMMARY.
Reasons for reissue of this instruction sheet are provided in Section 5, REVISION SUMMARY. Air Pressure 586.1 min 689.5 kpa max [85 min 100 psi max] Air Displacement 721,000 mm 3 [44 in. 3 ] Figure 1 Weight
More informationLenntech. 1000 psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503
1 User s Guide to: Phoenix Vessel Technology Limited 1000 psi End port pressure vessels 2.5. Model number: 1503 Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Phoenix
More informationCongratulations on your purchase of the Great Planes SLOT MACHINE, the first truly easy way to cut hinge slots in your model airplanes.
INSTRUCTION MANUAL Congratulations on your purchase of the Great Planes SLOT MACHINE, the first truly easy way to cut hinge slots in your model airplanes. The Slot Machine you have purchased is equipped
More informationInstallation Instructions / Warranty
Installation Instructions / Warranty Vertical Spray Bidet Fitting Rough 1322X181 Citterio 39224xx0 Citterio 39225xx0 Starck 10220xx0 Steel 35220800 Uno 38220xx0 Terrano 37224xx0 Terrano 37225xx0 Carlton
More informationSelect Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
More informationAssembly and instructions
Assembly and instructions Franke Minerva 3-in-1 Kettle Tap Retain for reference NB: For use only with Franke Heating Tank INTRODUCTION The Kettle Tap is suitable for dispensing boiling water (100 C) and
More informationModel 5600SE Downflow
Service Manual IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specification Sheet...................................................................................
More informationDissolved Oxygen Sensors
Instruction Sheet PN 51A-HxDO/rev.F June 2008 Models Hx438 and Gx448 Dissolved Oxygen Sensors For additional information, please refer to the Instruction Manuals CD shipped with this product, or visit
More informationREPAIR INSTRUCTIONS UNDER BODY CYLINDER (UM, UL)
Table of contents 1. Introduction... 3 1.1. Scope of use... 3 1.2. General remarks... 3 1.3. Contact Hyva... 3 1.4. Precautions... 4 1.5. Spare parts... 4 1.5.1. Prior to use... 4 1.6. Recycling and Reuse
More informationGGS 27 GGS 27 C PROFESSIONAL
GGS 27 GGS 27 C * Des idées en action. Bedienungsanleitung Operating instructions Instructions d emploi Instrucciones de servicio Manual de instruções Istruzioni d uso Gebruiksaanwijzing Betjeningsvejledning
More informationClikSTAR - Important facts about your new insulin delivery device.
ClikSTAR - Important facts about your new insulin delivery device. Instruction for Use ClikSTAR Insulin delivery device Before you start: Read these instructions and follow them completely each time you
More informationThe Drink-Aide The NEW look of independence
The Drink-Aide The NEW look of independence Introducing Drink-Aide What is Drink-Aide? The Drink-Aide is a water bottle that attaches easily to a wheelchair for use by persons with little or no upper
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
More informationSupport Cleaning Apparatus. Operation, Cleaning, & Safety Manual
Support Cleaning Apparatus Operation, Cleaning, & Safety Manual Revision 1.1 31 May 2014 WARNING: The instructions and precautionary statements contained herein are intended for the Support Cleaning Apparatus
More informationINSTALLATION, OPERATION & MAINTENANCE MANUAL
INSTALLATION, OPERATION & MAINTENANCE MANUAL Flanged Disk Check Valve with Strainer Ref. GENEBRE: 2450 2451 2452 1 INSTRUCTIONS FOR INSTALLATION, OPERATION & MAINTENANCE MANUAL 1. Spare parts... 3 1.1
More informationDentalaire Owner s Manual for all Dental Stations
Dentalaire Owner s Manual for all Dental Stations DENTALAIRE SET UP PROCEDURE FOR DENTALAIRE DENTAL STATIONS STEP # 1 - Open crate using a large screwdriver. Please check crate for any damages and report
More informationWaters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE
Waters Corporation Waters 2690/5 USER & TROUBLESHOOTING GUIDE Contents 2690/5 Theory Setup procedures. Troubleshooting the 2690/5 User maintenance of the 2690/5 Spare Parts 2 2690/5 Theory 2690/5 Solvent
More informationINSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX
Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into
More informationUSER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
More informationModel 5600 & 5600 Econominder
Service Manual IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specification Sheet...................................................................................
More informationGet Cleaning... User Guide Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308. Carpet Washer. vax.co.uk. Rapide Ultra series
W90-RU & W89-RU Series User Guide v1.4.qxd:user guide 2/3/11 10:03 Page 1 Carpet Washer User Guide Vax Careline: (UK) 0844 412 8455 Get Cleaning... What s your Vax model number? (Located on the top flap
More informationWipers and washers WINDSCREEN WIPERS. Intermittent variable delay
Wipers and washers WINDSCREEN WIPERS S Do not operate the wipers on a dry screen. The drag on the wiper mechanism may cause damage. Before operating in freezing or very hot conditions, ensure that the
More informationIMPORTANT DOCUMENTATION DO NOT DISCARD!
PART NO.: 6441-263C SERIES GRT 3 JAW PARALLEL GRIPPERS INFORMATION SHEET IMPORTANT DOCUMENTATION DO NOT DISCARD! Use this information sheet to assist with gripper installation and setup. File with maintenance
More informationKUSTER ELECTRONIC GAUGES
Kuster Company 2900 E. 29th Street Long Beach, CA USA 90806 Telephone 562-595-0661 Fax 562-426-7897 E-Mail kuster@kusterco.com KUSTER ELECTRONIC GAUGES K8 EMR 25, K8 EMR 39, K4 EMR ¾, K4 EMR ¾ QUARTZ SERVICE
More informationCompensation Unit in X-, Y-, and Z-Direction AGE-S-XYZ 100-200
Translation of the original manual Compensation Unit in X-, Y-, and Z-Direction AGE-S-XYZ 100-200 Assembly and Operating Manual Superior Clamping and Gripping Imprint Imprint Copyright: This manual remains
More information