RADIATION PROTECTION. Choose your application of. H ß - ɣ / ß + RAD Protect. personal dose rate meter. dose rate meter. portable.

Size: px
Start display at page:

Download "RADIATION PROTECTION. Choose your application of. H ß - ɣ / ß + RAD Protect. personal dose rate meter. dose rate meter. portable."

Transcription

1

2 Choose your application of RADIATION PROTECTION 3 H ß - ɣ / ß + personal dose rate meter DOSE GUARD dose rate meter GRAETZ X5C plus system portable contamination monitor INSPECTOR INSPECTOR CORA CORA hand, foot, cloths monitor HANNA HANNA water contamination monitor ALMO water monitor RAD Protect. air contamination monitor ALMO air monitor area - ɣ doserate monitor ALMO doserate monitor

3 DoseGUARD electronic dosimeter DoseGUARD S10 APPLICATION Dose / doserate meter personal dose doserate measurement GENERAL DESCRIPTION FEATURES DoseGUARD S10 - According to the German Radiation Protection Ordinance (StrlSchV 40, 41), the body dose of persons has to be determined. Upon request, the person to be monitored has to be provided with a dosimeter to be able to measure the personal dose at any time. For pregnant women, the radiation exposure at work has to be determined every week. pocket operation universal function ratemeter digital display Nowadays, for dose monitoring, modern powerful electronic dosimeters with easy to read LCD-display and definable dose and dose rate alarm thresholds are available. Dosimetry software DOSMO Electronic dosimeter like the DoseGUARD S10 can be used self-sufficiently as an independent single dosimeter. For larger groups of people, the electronic dosimeter can be read out automatically in connection with a PC-based dosimetry reading system and the evaluation software DOSMO. All dosimetry tasks defined in the German Radiation Protection Ordinance (StrlSchV) are fulfilled by this system. Via an interface, the dosimeter reading system reads the dose value stored in the dosimeter. The personal dose values are registered and used to calculate the week dose, month dose and year dose. Limit values can be monitored safely in this way. Further functions, e.g. period monitoring, annual protocols, monitoring of the access rights complete the performance spectrum. Our dosimetry system can be used as a single place system or connected to several reading systems as a network version

4 calibration station dosimeter reading system ADR with PC-system TECHNICAL DATA ORDERING INFORMATION DoseGUARD S10 personal dosimeter appropriate for calibration and capable of measuring the personal depth dose Hp(10) according to the new German Radiation Protection Ordinance (StrlSchV) qualification approval by the German Institute of Weights and Measures (PTB) digital display of dose and dose rate X-ray and gamma radiation 50 kev - 3 MeV DoseGUARD S10 Electronic Dosimeter DoseGUARD wall rack, 15 units calibration reading unit ADR1 option reading program DOSMO radioaktiv control unit installation silicon diode with energy compensation filter as detector alarm values for dose and dose rate definable, incl. acoustic and optical alarm RAD Protect. continuous self-check function very small dimensions, very low weight (80g) battery operated improved shielding against electromagnetic radiation Accessories: radioactive control device with 137 Cs-test source (3.7 MBq) for radiological check and semi-annual control of the calibrated dosimeter for prolongation of the calibration dosimeter validity. storage rack for dosimeter rack for storage of the dosimeters 15 storage positions

5 GRAETZ X5C plus dose rate measuring system APPLICATION personal radioation protection dose rate meter dose meter GENERAL DESCRIPTION FEATURES GRAETZ X5C plus dose rate meter for measuring gamma radiation and X-rays measurand: H*(10) (ambient dose rate equivalent) detector: energy compensated GM tube large, digital indication of measured values on LC-display (illuminable) selectable dose rate or dose indication with integration time additional quasi-analogue indication of dose rate (3.5 decades, logarithmic bargraph) indication of peak and average dose rate value 4 free programmable dose and dose rate alarm thresholds automatic or manual storage of measured dose rate values together with date and time evaluation/indication of residual time for staying in the current radiation field with regard to the maximum allowed dose switchable acoustic single-pulse indication clear menu-driven user navigation for easy operation, partly secured by password storage of set parameters even when the device is switched off or during battery change continuous self-testing and monitoring ensure high reliability compact metallized housing made of high impact-proof plastic, easy to decontaminate, protection class IP67 RS 232 interface basic unit can be combined either directly or by probe cable with various probes (see separate leaflet): for extending the measuring range up to 10 Sv/h for detecting αα-, ββ- and γɣ -radiation for measurement in liquids for measurements at hard-to-get-to places Telescope Probe DE for measurements from a safe distance Scintillation probe 2002 for measuring low dose rates 122

6 energy and angle dependence energy and angle dependence TECHNICAL DATA ORDERING INFORMATION GRAETZ X5C plus dose rate indication range: PTB-approved dose rate range: 1) dose indication range: dose measuring range: energy range: dose rate alarm thresholds: dose alarm thresholds: temperature range: dimensions: 0 nsv/h 20 msv/h 1.0 μsv/h 20 msv/h 0 nsv 10 Sv 0.5 μsv 10 Sv 40 kev 1.3 MeV 4, free programmable in the range 1 μsv/h 20 msv/h 4, free programmable in the range 1 μsv 10 Sv -30 C up to +60 C (152 x 82 x 39) mm approx. 400 g GRAETZ X5C plus calibration GRAETZ X5C plus option PC + Windows program RAD Protect. power supply: 9 V battery 6LR61 alarm: 80 db(a) measured in 30 cm distance PTB Approval No.: 23.51/04.01 german fire brigades approval no.: DL / FW / IdF / 1 1) PTB-approved measuring range for measurements specifically demanded by German regulations

7 INSPECTOR α, β, ɣ hand-held radiation detector APPLICATION α, β, ɣ radioactivity meter local inspection of contamination dose/doserate GENERAL DESCRIPTION FEATURES INSPECTOR is a simple, universal, handheld radioactivity detector, sensitive for alpha, beta, gamma and x-ray radiation. INSPECTOR has a large window Geiger-Mueller counting tube with a window diameter of 45 mm. INSPECTOR has an optical and acoustical event indicator. INSPECTOR can be used as ratemeter or scaler/timer for momentary or long term measurements. one hand operation universal function ratemeter and scaler/timer digital display large area window GM-tube SPECIFICATIONS FOR SEVERAL NUCLIDES isotope Emax in kev efficiency INSPECTOR can display activity in total counts (accumulated in time) counts per second and counts per minute INSPECTOR can display doserate in mrem/h µsv/h 14 C % 147 Pm % 99m Tc % 36 Cl % 90 Sr % 241 Am % 124

8 top view back view TECHNICAL DATA ORDERING INFORMATION INSPECTOR: detector: window: display: timer: counter: ratemeter range: Geiger-Mueller 45 mm diameter 2 mg/cm 2, mica 4 digit LCD 1-10 min, in 1 min steps min, 10 min steps 1 24 h. step 1 h steps counts c/m c/s INSPECTOR radiation alert update: doserate: accuracy: (ref. to Cs-137) anti saturation: output: temperature: power: dimensions: 3 s 1 µr/h 100 mr/h 0.01 msv/h 1000 msv/h +/-15 % from 0-50 mr/h +/-20 % from mr/h +/-15 % from c/m +/-20 %, c/s holds full scale in radiation field of 100 times full scale CMOS or TTL counts to PC or data logger -10 to +50 C alkaline battery, 9 V 150 x 80 x 30 mm 272 g RAD Protect.

9 CoMo 170 portable contamination monitor APPLICATION α, β, ɣ surface contamination bench, floor, wall, door hand, foot, shoe, cloth GENERAL DESCRIPTION FEATURES CoMo 170 is using 2 scintillator materials. For detection of alpha-radiation ZnS is used. For detection of beta and gamma radiation a plastic scintillator foil is used. The large area detector window is permeable for low energy alpha radiation like 238 U beta radiation like 14 C The thin window can be replaced easily by the user and measurements can be continued without much delay. The light flashes generated by the alpha or beta/gamma radiation can be separated by pulse analysis. The detected events are counted over time and displayed digitally in c/s, Bq or Bq/cm 2. Nuclide specific sensitivity is calculated and alarm values are preprogrammed. alpha-, beta- and gamma-sensitivity one detector, large area 170 cm 2 selective alpha or beta / gamma detection scintillation probe no counting gas EFFICIENCY FOR VARIOUS NUCLIDES 14 C 14 % 18 F 18 % 32 P 25 % 35 S 12 % 36 Cl 42 % 40 K 30 % 57 Co 7 % 60 Co 27 % 89 Sr 27 % 90 Sr/( 90 Y) 42 % 99m Tc 3 % 111 In 8 % 123 I 7 % 125 I 12 % 131 I 21 % 137 Cs 35 % 198 Au 23 % 204 Tl 43 % 241 Amα 22 % 238 Puα 12 % 238 U α 26 % Measurement results can be stored and transferred by RS 232 C

10 CORA on floor trolley CORA on wall holder TECHNICAL DATA ORDERING INFORMATION CoMo detector type: detector size: 170 cm 2 background: background subtr.: thin layer plastic sintillator with ZnS coating alpha 0.1 c/s beta c/s adjustable background measurement time measurement electr.: µ- controller supported electronics keyboard: alarm: result display: measurement time: display: power supply: temperature range: dimension: interface: foil keyboard 5 function keys separately adjustable for each nuclide acoustic alarm 25 nuclides preset calibration factors user specific nuclides may be added integrated autocalibration continuous,for stationary application adjustable in seconds large area graphical LCD display 128 x 64 pixel with illumination duration of illumination adjustable 2 batteries, AA Mignon or rechargeable batteries can be charged by charge unit in stationary mode via wall station with inductive charge conservation -10 to +40 C no condensation 280 x 125 x 135 mm 750 gr. RS 232 C CoMo 170 alpha-, beta-, gammacontamination and radiation monitor window 170 cm 2 option beta reference standard 14 C, Ø 50 mm, 1 kbq beta reference standard 137 Cs, 100 cm 2, 1 kbq CoMo wall holder CoMo battery charger CoMo floor control device CoMo170 DL contamination and doserate monitor CoMo software for reading measured data CoMo 300 alpha-, beta-, gammacontamination and radiation monitor window 300 cm 2 PC + Windows program RAD Protect.

11 HFC hand-,foot- & cloths-monitor APPLICATION α, β, ɣ control area for radioactive laboratory control area for radiopharmaceutical laboratory control area for PET synthesis and quality control laboratory GENERAL DESCRIPTION FEATURES HFC is using 2 scintillator materials. For detection of alpha-radiation ZnS is used. For detection of beta and gamma radiation a plastic scintillator foil is used. The large area detector window is permeable for low energy alpha radiation like 241 Am beta radiation like 14 C The thin window can be replaced easily by the user and measurements can be continued without much delay. The light flashes generated by the alpha or beta/gamma radiation can be separated by pulse analysis. The detected events are counted over time and displayed digitally in c/s, Bq or Bq/cm 2. Nuclide specific sensitivity is calculated and alarm values are preprogrammed. alpha-, beta- and gamma-sensitivity 2 hand detectors, 2 foot detectors 1 body detector (right hand probe detachable) selective alpha or beta/gamma detection scintillation probe no counting gas nuclide specific display and alarm efficiency for various nuclides 14 C 8 % 36 Cl 40 % 60 Co 23 % 90 Sr/ 90 Y 49 % 99m Tc 5 % 125 I 13 % 131 I 23 % 241 Am 25 % Measurement results can be stored and transferred by RS 232 C

12 reduced width version 4-Hand-Detector version TECHNICAL DATA ORDERING INFORMATION HFC detector type: thin layer plastic scintillator with ZnS coating HFC alpha-, beta-, gammahand, foot, cloth-monitor detector size: background subtr.: hand: 375 cm 2, (15 x 25 cm) foot: 450 cm 2, (15 x 30 cm) adjustable background measurement time measurement electr.: integrated PC 104 keyboard: alarm: result display: measurement time: display: silicon keyboard separately adjustable for each detector selectable in c/s or nuclide related in Bq/cm 2 adjustable in s large area graphical colour LC display, 10,4" beta reference standard 137 Cs, 100 cm2, 1 kbq option PC + Windows program installation transpondersystem for auto. person ID transponder hand, foot, clothes administration software RAD Protect. power supply: dimension: 230 V, 50 Hz 1160 x 830 x 700 mm 45 kg interface: RS 232 C parallel printer interface external keyboard floppy disk drive 3,5" network connection RJ45

13 ALMO-water installed ɣ-waste-water-contamination monitor APPLICATION ɣ radio-pharmacy-lab PET-quality-control-lab nuclear-medicine-lab ALMO 1 GENERAL DESCRIPTION FEATURES ALMO 1 is a multi-purpose radiation monitoring system for a range of radiation protection applications. ALMO 1 operates with a 1,5x1", 2x2" or 3x3" Nal(TI) crystal integraline assembly. For remote operation the high voltage is generated in the socket. Amplifier and energy discriminator are adaptable for all applications. For high activity applications or long distance operation, a puls rate divider can be used, which can be compensated by the parameter setting of the ALMO 1. The threshold of activity to close or open an electromagnetic valve for storing or releasing the radioactive waste water can be programed by ALMO 1. The waste water storage capacity can be adapted to the required operation conditions. life display c/s, Bq, Bq/m 3 alarm level programable intermediate storage of high activity continuous measurement during storage release after decay to puplic drain option: PC recording / integration 130

14 waste water container and probe recording and integration over time TECHNICAL DATA ORDERING INFORMATION ALMO 1 scintillation probe: electronic: display: keyboard: ranging: intervaltime: alarm: I/O: Nal (TI) 1,5x1" or 2x2" or 3x3" μ- controller LCD with black light foil automatic programmable 2 level settings 3 outputs 24 V, 500 ma or potential free, max. 24 V, 1 A 1 3 stage light, horn, interlock RS 232 / 422 / 485 or USB ALMO 1 alarm monitor wall or table mount scintillation probe 3x3 option PC + Windows program optical alarm unit, 2-stage installation RAD Protect.

15 ALMO-air installed ɣ- air contamination monitor APPLICATION ɣ radioactive air monitor recorded per second interratable per minute, hours, days,, weeeks, months, years exhaust air system Introduction The generation of radionuclides in a PET Centre may produce air contaminations of the enviroment. Radioactivity may leak from the generator to the environment. Radionuclides may escape during the transfer from the generator target to the synthesis cell. During the synthesis of radioactive tracers the process is almost never 100 % tight and radioactivity may escape. The activity of the production batch can be so high that there is a serious danger of exposure. Therefore, the need for measurement of air contaminations is evident. Indeed, these measurements are required by law. The ventilation channel The generator and the synthesis facilities are usually accommodated in a well shielded part of the basement of a building. The ventilation exit of the PET-Lab is usually located over the roof. The ventilation system will transport the potential air contamination from the PET-Lab in the basement a long way over the roof. The length and pathway of the ventilation channel can be quite complicated. Furthermore, the structure of the ventilation channel is quite difficult to take into consideration. Last but not least, the natural and artifacial depositions in the ventilation channel may create an additional problem. This means that theoretical calculations about the entry, distribution, adsorption, swirling, transportation and delay of the radioactive air fraction are very difficult. The only reliable method is an exat measurement of a well defined gaseous radioactivity emission. For a cyclotron with a gas target, we recommend to generate 11 CO 2, an almost inert gas which mixes quite well with the ventilated air. Nitrogen generation may be considered for cyclotrons without gas target. Radioactives gas release device The operation computer of the activity generator selects all parameters for production of a nominal total activity. As soon as the total activity is reached, the radioactivity fraction is transferred from the target to a release device installed in a shielded box. The release device contains a coiled, metal tubing mounted in the well of an ionisation chamber. The radioactivity fraction is fixed in a metal coil positioned in the well of an ionisation chamber. the net volume of the coil is 70 ml. The absorption of gamma radiation of 511 kev in the wall of the coil-tubing is neglected. The well-type ionisation chamber is calibrated for PET-nuclides and measures the enclosed radioactivity fraction with high accuray. As soon as the total radioactivity in the coil is determined exactly, the sample is released in the ventilation system at a precise time. After a long enough time for dispensing the radioactivity from the coil, the release is terminated and the remaining activity in the coil is determined. At exactly the same time, the radioactivity recording system at the exit of the ventilation over the roof is started. The number of detected events of radioactivity is counted in small time elements, displayed and stored. A seperate device for measuring the air flow speed is installed close to the radioactivity detector in order to calculate the radioactivity per volume

16 Released radioactivity / MBq Display in second, minutes, hours integratable in days, weeks, months and years Calibration The recorded profile of the radioactive cloud passing the radioactivity detector on the roof exit is recorded over time and the number of detected counts is determined for every emitted radioactivity fraction. The flow time from the release-point to the detector is recorded. The release of various radioactivity fractions calibrated in Bq is set out with the detected number of counts for every fraction and completed in a calibration graph. The graph shows that the detection system is linear over the entire range from background to maximum possible radioactivity release. The countrate of the radioactivity detector at background is usually quite low and consequently the reaction speed of any alarm is too low. The maximum countrate of the radioactivity detector for accindental emissions of high PET activities is usually not high enough. Both the low countrate and the maximum countrate are realized in the special design of the radioactive air contamination detector. Recording After the system has been calibrated, the radioactivity emission can be recorded and displayed in a graph over time. The radioactivity is recorded digatally in number of counts in the small time interval of 1 sec. The recording shows no saturation effect at any scale. Ranges are selected automatically without any range overriding. The time scale of a running measurement can be set to minutes, hours, days, weeks, months and year without losing any information. Total Emission of Radioactive Air The integration of all emissions over a long period of time detemines the total radioactivity emission in air over a selected long period. The regulatory authority granting the permission of operation will specify the maximum radioactivity emission per year. The raytest radioactivity air surveillance system will measure the radioactivity emission and relate it to the permitted maximum. ORDERING INFORMATION ALMO 1 alarm monitor air contamination flow cell shielding for air flow cell scintillation probe 3x3" air-mass-flow measurement system software ALMO PC installation PC + Windows program RAD Protect.

17 ALMO-doserate installed ɣ- doserate monitor APPLICATION ɣ installed ɣ-doserate installed ɣ-alarm installed door lock central data presentation central alarm signal ALMO 1 GENERAL DESCRIPTION FEATURES ALMO is a multi-purpose radiation monitoring system for range of radiation protection applications. ALMO can operate various Geiger-Müller-detectors as well as neutron- and Nal-detectors. ALMO is avialable for 1, 1-3, and 1-6 detectors operating simultaneously. ALMO has an automatic detector recognition. ALMO offers for every single probe programable alarm settings for 1, 2 or 3 levels. ALMO offers various programable outputs signals. ALMO has a LCD with backlight illumination. ALMO offers communication via RS 232, 422, 485 and USB. ALMO can operate in a network of up to 5 ALMOS with a total of 30 individual destectors. ALMO transfers all measurement value as well as all warnings to the central PC. ALMO can have a secondary display and alarm unit. bright display readable from distance 1, 1 3, 1 6 -probe operation low, medium and high gamma dose rate system neutron dose rate system automatic ranging programable alarm data transfer to PC recording over hours, days, weeeks, months, years integration over any time TYPE GM-detector C energy range: 40 kev MeV measurement range: 150 nsv/h μsv/h dimensions: length 345 mm, Ø 25/40 mm 380 g GM-detector C energy range: measurement range: dimensions: 40 kev MeV 1 μsv/h - 20 msv/h length 10 mm, Ø 40 mm 150 g GM-detector C energy range: measurement range: dimensions: GM-detector C energy range: measurement range: dimensions: 55 kev MeV 10 μsv/h - 1 Sv/h length 110 mm, Ø 40 mm 150 g 70 kev - 3 MeV 100 μsv/h - 10 Sv/h length 110 mm, Ø 40 mm 150 g NaI-scintillation detector 25B38 energy range: 25 kev MeV measurement range: 40 nsv/h μsv/h dimensions: length 38 mm (active range), Ø 25 mm, 200 g 134

18 radiation surveillance floor plan ALMO 6 TECHNICAL DATA ORDERING INFORMATION ALMO ALMO 1: ALMO 3: ALMO 6: display: keyboard: alarm: temperature range: I/O: µ- controller supported for 1 detector for 1 3 detectors for 1 6 detectors LCD with background illumination foil keyboard optical, acoustical, option, external warning unit C, 0 96 % relative humidity non condensing 3 outputs, 24 V, 500 ma or 3 potential free, 24 V, 1 A for 3-step warning light, horn, interlock, RS 232/422/485 or USB ALMO 1 wall mount incl. mounting device cabeling exit up ALMO 3 wall mount incl. mounting device cabeling exit up ALMO 6 wall mount incl. mounting device cabeling exit up dose rate GM probe µsv/h 20 msv/h dose rate GM probe µsv/h 1 Sv/h dose rate GM probe µ 10 Sv/h scintillation probe 1,5 x 1" NaI 40 nsv/h 200 µsv/h warning unit, 1 step warning unit, 2 step RAD Protect. dimensions ALMO 1: power: 200 x 150 x 75 mm, table or wall mount V, Hz, 15 W 700 g warning unit, 3 step secondary alarm unit LCD, 3 LED, horn software ALMO, 5 m cable to PC installation ALMO 3/6: 280 x 300 x 120 mm, table or wall mount power: V, Hz, 60 W 2,2 kg

Turnkey Solutions for Radiation Protection in PET Laboratories R A D I A T I O N P R O T E C T I O N

Turnkey Solutions for Radiation Protection in PET Laboratories R A D I A T I O N P R O T E C T I O N Turnkey Solutions for Radiation Protection in PET Laboratories R A D I A T I O N P R O T E C T I O N Berthold Technologies has more than 60 years experience in manufacturing radiation protection measuring

More information

Bulk Flow Meter LB 442 P R O C E S S C O N T R O L

Bulk Flow Meter LB 442 P R O C E S S C O N T R O L Bulk Flow Meter LB 442 P R O C E S S C O N T R O L Mass flow determination using the LB 442 Versatile uses Contactless mass flow determination of solid matter on continuous conveyor systems Conveyor belts

More information

Cronos -1 Gamma Object / Tool Monitors

Cronos -1 Gamma Object / Tool Monitors Features Counting chamber volume: 42.9 L (1.5 cu. ft.) Robust, ergonomic, easy-to-use and decontaminate Photon energy range from 50 kev to 2 MeV Four or optional six large surface area plastic scintillator

More information

Radiation Monitoring System DLMon

Radiation Monitoring System DLMon Radiation Monitoring System DLMon Fields of Application: Dose rate monitoring system for use in nuclear medicine Area monitoring ( e.g. manufacturing of radionuclides, laboratories, nuclear power plants,

More information

G64 Area Gamma Monitor

G64 Area Gamma Monitor Features Solid state detector: range 0.1 µsv/h to 100 msv/h (10 µr/hr 10 R/hr) Pseudo-logarithmic ratemeter averaging for good statistics at low level and fast response at high levels Removable detector

More information

PROFORMA ACCEPTANCE / QUALITY ASSURANCE TESTS OF REMOTE AFTERLOADING BRACHYTHERAPY UNIT

PROFORMA ACCEPTANCE / QUALITY ASSURANCE TESTS OF REMOTE AFTERLOADING BRACHYTHERAPY UNIT RP&AD /Remote QA/ 01 PROFORMA FOR ACCEPTANCE / QUALITY ASSURANCE TESTS OF REMOTE AFTERLOADING BRACHYTHERAPY UNIT BHABHA ATOMIC RESEARCH CENTRE Radiological Physics & Advisory Division CT & CRS Building,

More information

Incubator with mechanical convection

Incubator with mechanical convection BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,

More information

Radiation Monitoring System RMS

Radiation Monitoring System RMS Radiation Monitoring System RMS VF RMS radiation monitoring system is a modular and standardized system for the radiological monitoring. Variety of radiation monitors, display and alarm units can be connected

More information

INFO-0545 RADIOISOTOPE SAFETY MONITORING FOR RADIOACTIVE CONTAMINATION

INFO-0545 RADIOISOTOPE SAFETY MONITORING FOR RADIOACTIVE CONTAMINATION INFO-0545 RADIOISOTOPE SAFETY MONITORING FOR RADIOACTIVE CONTAMINATION 1. INTRODUCTION This document provides general guidance for monitoring and controlling radioactive contamination, and relating the

More information

Material test chamber with mechanical convection

Material test chamber with mechanical convection FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and

More information

Application Note. ipix A Gamma imager to support various applications

Application Note. ipix A Gamma imager to support various applications Application Note ipix A Gamma imager to support various applications Introduction ipix is a unique gamma imager that quickly locates low level radioactive sources from a distance and estimates the dose

More information

BB-18 Black Body High Vacuum System Technical Description

BB-18 Black Body High Vacuum System Technical Description BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The

More information

RADIATION PROTECTION. Alpha-Beta Particulates Monitor LB 150 D-R. ABPD Particulates Monitor combined with Alpha Energy Range Discrimination (AERD)

RADIATION PROTECTION. Alpha-Beta Particulates Monitor LB 150 D-R. ABPD Particulates Monitor combined with Alpha Energy Range Discrimination (AERD) Alpha-Beta Particulates Monitor RADIATION PROTECTION ABPD Particulates Monitor combined with Alpha Energy Range Discrimination (AERD) Simultaneous Measurement of Artificial Alpha- and Beta-Particulates

More information

Product Information Sheet UH36 Hi Pot Tester

Product Information Sheet UH36 Hi Pot Tester Product Information Sheet UH36 ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: info@etl-prueftechnik.de Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet: www.etl-prueftechnik.de

More information

Selection, use and maintenance of portable monitoring instruments

Selection, use and maintenance of portable monitoring instruments HSE information sheet Selection, use and maintenance of portable monitoring instruments Ionising Radiation Protection Series No 7 Introduction The Ionising Radiations Regulations 1999 (IRR99) 1 require

More information

thyroid uptake systems www.capintec.com

thyroid uptake systems www.capintec.com 64 thyroid uptake systems Captus 3000 Thyroid Uptake System Comprehensive Software Quick-start feature for rapid set-up User defined, HIPAA compliant counting protocols Thyroid uptake Wipe test Bioassay

More information

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances Operating Instructions MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances 15043 1/1.00 10 9 8 1 7 6 1 Display 2 Slider switch cd/m² segment test 3 ON/OFF switch 4

More information

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Visions become real. Temperature control and cooling systems. The innovative and reliable solution Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature

More information

Application Note. Monitoring the Release of Radioactive Noble Gases Through the Stack of a Nuclear Power Plant (NPP): Stack Monitor System

Application Note. Monitoring the Release of Radioactive Noble Gases Through the Stack of a Nuclear Power Plant (NPP): Stack Monitor System Application Note Monitoring the Release of Radioactive Noble Gases Through the Stack of a Nuclear Power Plant (NPP): Stack Monitor System Based on the German KTA 1503.1 and respective international regulations,

More information

RADIATION MONITORING SYSTEMS

RADIATION MONITORING SYSTEMS RADIATION MONITORING SYSTEMS Area monitors Process monitors In-line, Adjacent-to-Line monitors Local/remote processors, Data Acquisition Systems NUPIC Certified, NRC Approved Vendor Wide Range Sensitivity

More information

ELECTRA/SELECTRA Ratemeter. Operators Manual

ELECTRA/SELECTRA Ratemeter. Operators Manual ELECTRA/SELECTRA Ratemeter Operators Manual March 2004 Thermo Electron Corporation 2005 ALL RIGHTS RESERVED. REPRODUCTION IN WHOLE OR IN PART OF ALL MATERIAL IN THIS PUBLICATION, INCLUDING DRAWINGS AND

More information

Use of the VALIDATOR Dosimetry System for Quality Assurance and Quality Control of Blood Irradiators

Use of the VALIDATOR Dosimetry System for Quality Assurance and Quality Control of Blood Irradiators Technical Note: 9 Use of the VALIDATOR Dosimetry System for Quality Assurance and Quality Control of Blood Irradiators 1- Introduction The VALIDATOR, model TN-ID-60, is a compact, and stand-alone dosimetry

More information

Radiation Detector with USB port. Measures Radioactivity Easily and Reliably. gamma-scout.com

Radiation Detector with USB port. Measures Radioactivity Easily and Reliably. gamma-scout.com Measures Radioactivity Easily and Reliably. Information on GAMMA-SCOUT, instructions for TOOLBOX software (processes GAMMA-SCOUT data) and technical support available at gamma-scout.com Radiation Detector

More information

OT 40L / 90L. Laboratory Steam Sterilizers

OT 40L / 90L. Laboratory Steam Sterilizers OT 40L / 90L Laboratory Steam Sterilizers OT 40L / 90L LABORATORY STEAM STERILIZERS OT 40L / OT 90L laboratory steam sterilizers are specially designed for the steam sterilization of liquid and culture

More information

Ludlum Measurements, Inc. Domestic Price List August 10, 2016

Ludlum Measurements, Inc. Domestic Price List August 10, 2016 Ludlum Measurements, Inc. Domestic Price List August 10, 2016 Item Part Number Price General Purpose Portable Meters (Analog) Model 3 Survey Meter 48-1605 $599.00 Model 3A Survey Meter with Alarm 48-1408

More information

STERILIZERS, LABORATORY DRYING OVENS

STERILIZERS, LABORATORY DRYING OVENS TS9026 TS9053 TS9135 TS9430 TS 9000 SERIES: STERILIZERS, LABORATORY DRYING OVENS Series TS9000 consists of four different cabinets available in sizes from 26 litres to 430 litres. Interior housing and

More information

Report on heat production during preliminary tests on the Rossi Ni-H reactor.

Report on heat production during preliminary tests on the Rossi Ni-H reactor. Report on heat production during preliminary tests on the Rossi Ni-H reactor. Dr. Giuseppe Levi In this first and preliminary document are reported the heat production measures done during two short tests

More information

P O L Y T E C R.M. S.R.L.

P O L Y T E C R.M. S.R.L. INFORMACIÓN FUENTES EXCEPTUADAS PARA ENSEÑANZA RSS-2 G-M Resolving Time Set This set is used for determining the resolving time of GM Counters. It consists of three half discs, two of which contain 5 microcuries

More information

Precision Lightmeters Made in Germany

Precision Lightmeters Made in Germany Lightmeters Luxmeters, Footcandle Meters Precision Lightmeters Made in Germany Luminance Meters www.gossen-photo.de Luxmeters / Footcandle Meters MAVOLUX 5032 C/B USB Illuminance meters of the precision

More information

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-500/600 Series Low-Cost Data Loggers and Accessories Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low

More information

EMERGENCY PROCEDURES FOR RADIOACTIVE MATERIAL. 2. Prevent the spread of contamination by covering the spill with absorbent paper.

EMERGENCY PROCEDURES FOR RADIOACTIVE MATERIAL. 2. Prevent the spread of contamination by covering the spill with absorbent paper. EMERGENCY PROCEDURES FOR RADIOACTIVE MATERIAL MINOR SPILLS: 1. Notify persons in the area that a spill has occurred. 2. Prevent the spread of contamination by covering the spill with absorbent paper. 3.

More information

Measuring electric and magnetic fields

Measuring electric and magnetic fields NARDA BROADBAND FIELD METER NBM-520 Measuring electric and magnetic fields ranging from high frequency to microwaves Non-directional measurement using isotropic probes for applications in the frequency

More information

Experiment 10. Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado

Experiment 10. Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado 1 Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado Introduction Some radioactive isotopes formed billions of years ago have half- lives so long that they are

More information

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.

More information

C-10 Radiation Monitoring Network

C-10 Radiation Monitoring Network C-10 Radiation Monitoring Network Table of Contents C-10 Foundation History C-10 Mission & Goals History of C-10 Radiological Monitoring Network C-10 Radiation Monitoring Network (CRMN) CRMN System Architecture

More information

BERKELEY NUCLEONICS USER MANUAL BNC MODEL 960. This manual covers installation and operation procedures for BNC AM members:

BERKELEY NUCLEONICS USER MANUAL BNC MODEL 960. This manual covers installation and operation procedures for BNC AM members: BERKELEY NUCLEONICS USER MANUAL BNC MODEL 960 This manual covers installation and operation procedures for BNC AM members: Berkeley Nucelonics - 2955 Kerner Blvd. San Rafael, CA 94901 - (415)453-9955 -

More information

1/4 Specifications Hidex 300 SL automatic TDCR liquid scintillation counter

1/4 Specifications Hidex 300 SL automatic TDCR liquid scintillation counter 1/4 1.11.2010 Specification Hidex 300 SL 100-240V AC and 24 V DC. Features Model (425-201) Automatic TDCR Liquid Scintillation Counter General Description Hidex 300SL automatic TDCR liquid scintillation

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

Heating oven with mechanical control

Heating oven with mechanical control ED series 53 Drying ovens / Heating ovens Heating oven with mechanical control The strength of the BINDER ED series heating oven: routine drying and sterilization applications up to 300 C (572 F). Thanks

More information

Physical Specifications (Custom design available.)

Physical Specifications (Custom design available.) Helmholtz Coils A useful laboratory technique for getting a fairly uniform magnetic field, is to use a pair of circular coils on a common axis with equal currents flowing in the same sense. For a given

More information

Heating oven with mechanical convection

Heating oven with mechanical convection FD series 53 Drying ovens / Heating ovens Heating oven with mechanical convection A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous

More information

Drayton Digistat +2RF/+3RF

Drayton Digistat +2RF/+3RF /+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer

More information

5000V Graphical Megohmmeter Model 5070

5000V Graphical Megohmmeter Model 5070 5000V Graphical Megohmmeter Model 5070 The Model 5070, the latest design in 5000V Megohmmeters, is the most innovative product in its class on the market today. The features and functions incorporated

More information

Development and Experimental Performance Evaluation of a Dose-Rate meter for Pulsed Beam.

Development and Experimental Performance Evaluation of a Dose-Rate meter for Pulsed Beam. 5 th International Workshop on Radiation Safety at Synchrotron Radiation Sources Development and Experimental Performance Evaluation of a Dose-Rate meter for Pulsed Beam. A. Vascotto 1, K. Casarin 1, S.

More information

USB-500 Series Low-Cost Data Loggers and Accessories

USB-500 Series Low-Cost Data Loggers and Accessories Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low

More information

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) DESCRIPTION The Radar Level Meters of BM COMPACT WAVE 6.3 GHz series are excellent devices for no contact level measurement. The microwave impulses, emitted

More information

User Manual. Humidity-Temperature Chart Recorder. Model RH520

User Manual. Humidity-Temperature Chart Recorder. Model RH520 User Manual Humidity-Temperature Chart Recorder Model RH520 Introduction Congratulations on your purchase of the Extech RH520 Temperature + Humidity Chart Recorder. The RH520 measures and displays Temperature,

More information

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS Vehicle or Personal Position Tracking Vehicle Status and Speed Tracking Auto Accident Report Global Position System (GPS) Navigation System Anti theft Alarm System Overview 1. GPS data tracking via GSM

More information

Hand-held thermometer Model CTH7000

Hand-held thermometer Model CTH7000 Calibration technology Hand-held thermometer Model CTH7000 WIKA data sheet CT 55.50 Applications Precision thermometer for very accurate temperature measurements in a range of -200... +962 C Reference

More information

Multi Media Cable Tester TM-901N/TM-902/TM-903

Multi Media Cable Tester TM-901N/TM-902/TM-903 Multi Media Cable Tester TM-901N/TM-902/TM-903 User Manual HB2TM9020010 TENMARS ELECTRONICS CO., LTD Table of Contents 1 Introduction... 1 2 Safety Precaution... 1 3 The verifier does the following:...

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

CONFIGURABLE SAFETY RELAYS

CONFIGURABLE SAFETY RELAYS MSI-m/R, MSI-mx/Rx Configurable MSI Safety Relay with function for efficient material flow in a packaging application Special features Sequential or Parallel with automatic mode detection MSI-mx for separate

More information

Product Guide. experience & expertise ISSUE 1. België / Belgique T +31 (0)24 648 86 88. Nederland. www.gotopeo.com. info@gotopeo.

Product Guide. experience & expertise ISSUE 1. België / Belgique T +31 (0)24 648 86 88. Nederland. www.gotopeo.com. info@gotopeo. experience & expertise Product Guide ISSUE 1 Nederland België / Belgique T +31 (0)24 648 86 88 T +32 (0)3 309 32 09 info@gotopeo.com www.gotopeo.com Product Guide UK BASED MANUFACTURER OF RADIATION DETECTORS

More information

User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510

User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510 User Guide Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved

More information

Ron 3025 Crane Scale with 1"/25mm Display

Ron 3025 Crane Scale with 1/25mm Display Exceptionally small dimensions enable minimum headroom loss. For example: Height of the 5t load cell is 16.7 inch / 423 mm Optional shock absorbing protective cage Optional IR remote control Short delivery

More information

Highly efficient flue gas analyzer

Highly efficient flue gas analyzer Highly efficient flue gas analyzer testo 320 Just a few clicks away from a heating system diagnosis O 2 High-resolution colour graphic display Quick and easy menu structure Storage space for 500 measurement

More information

A Comparison of an HPGe-based and NaI-based Radionuclide Identifier (RID) for Radioactive Materials

A Comparison of an HPGe-based and NaI-based Radionuclide Identifier (RID) for Radioactive Materials Illicit Trafficking, Sub/cross-national threats, Poster presentation A Comparison of an HPGe-based and NaI-based Radionuclide Identifier (RID) for Radioactive Materials Ronald M. Keyser, Timothy R. Twomey,

More information

FRACTION COLLECTOR. Microcomputer Controlled CHF122SC

FRACTION COLLECTOR. Microcomputer Controlled CHF122SC FRACTION COLLECTOR Microcomputer Controlled CHF122SC From open column to HPLC liquid chromatography and general liquid samplings, the Super Fraction Collector, model CHF122SC has a wide range of uses.

More information

Product Information Sheet UH28CS-12kV Hi Pot Tester

Product Information Sheet UH28CS-12kV Hi Pot Tester Product Information Sheet UH28CS-12kV ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: info@etl-prueftechnik.de Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet:

More information

HYDRUS ULTRASONIC METER

HYDRUS ULTRASONIC METER HYDRUS APPLICATION HYDRUS is a static water meter based on the ultrasonic technology. This technology enables accurate calculation of water consumption and eliminates measuring deviations caused by sand,

More information

How To Use A Ds340 (Dsp)

How To Use A Ds340 (Dsp) Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Test equipment for temperature and its reduction

Test equipment for temperature and its reduction Data sheet 90.2721 Page 1/6 Test equipment for temperature and its reduction Pt100 precision RTD temperature probe Calibrated temperature measuring chain with precision display device Calibrations as service

More information

X-Mind. Instinct for perfection

X-Mind. Instinct for perfection X-Mind Instinct for perfection X-Mind tubes are located at the back of the head which gives the patient better protection because the distance between the focal spot and the skin is 50% greater than in

More information

DOSISYS DMC 2000. Dosimeters S, X, XB. User's Manual 128104-1

DOSISYS DMC 2000. Dosimeters S, X, XB. User's Manual 128104-1 DOSISYS DMC 2000 Dosimeters S, X, XB User's Manual 128104-1 Revision Table DMC 2000 S, X, XB To use your DMC 2000 immediately in stand-alone mode * refer to the following : Operation in the Stand-alone

More information

Hygro-Thermometer + InfraRed Thermometer Model RH101

Hygro-Thermometer + InfraRed Thermometer Model RH101 User's Guide Hygro-Thermometer + InfraRed Thermometer Model RH101 Introduction Congratulations on your purchase of the Extech Hygro-Thermometer plus InfraRed Thermometer. This device measures relative

More information

Curing Lights HALOGEN CURING LIGHTS 5.2 L.E.D. CURING LIGHTS 5.3 LIGHT GUIDES 5.5 RADIOMETERS 5.6 ACCESSORIES FOR CURING LIGHTS 5.

Curing Lights HALOGEN CURING LIGHTS 5.2 L.E.D. CURING LIGHTS 5.3 LIGHT GUIDES 5.5 RADIOMETERS 5.6 ACCESSORIES FOR CURING LIGHTS 5. Curing Lights 5 HALOGEN CURING LIGHTS 5.2 L.E.D. CURING LIGHTS 5.3 LIGHT GUIDES 5.5 RADIOMETERS 5.6 ACCESSORIES FOR CURING LIGHTS 5.6 Halogen Curing Lights Optilux 501 The most versatile and high power

More information

Operating instructions Platform/floor scales

Operating instructions Platform/floor scales KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating instructions Platform/floor scales KERN

More information

Passive Whole Body Monitoring Nuclear Power Industry Application Introduction to the Argos -5AB Zeus (Gamma Option) and the GEM

Passive Whole Body Monitoring Nuclear Power Industry Application Introduction to the Argos -5AB Zeus (Gamma Option) and the GEM Application Note Passive Whole Body Monitoring Nuclear Power Industry Application Introduction to the Argos -5AB Zeus (Gamma Option) and the GEM -5 Gamma Exit Monitor CANBERRA s personnel contamination

More information

MEASURING & CONTROL UNITS FOR PUBLIC SWIMMING POOLS

MEASURING & CONTROL UNITS FOR PUBLIC SWIMMING POOLS MEASURING & CONTROL UNITS FOR PUBLIC SWIMMING POOLS Measuring and Controlling Equipment ensuring required water quality in public pools. This is fully automatic measuring and controlling equipment with

More information

Emergencies Involving Radiation

Emergencies Involving Radiation Page 1-1 Section 1 Emergencies Involving Radiation Contents A. Emergency Phone Numbers...1-2 1. Campus... 1-2 a. Radiation Safety Office 543-0463... 1-2 b. University Police 9-911... 1-2 2. Off Campus...

More information

RADIATION DETECTION & ANALYSIS SYSTEMS FOR WATER

RADIATION DETECTION & ANALYSIS SYSTEMS FOR WATER RADIATION DETECTION & ANALYSIS SYSTEMS FOR WATER On Line Remote Sensing Systems On-line remote monitoring of gamma radiation in seawater using spectroscopy and gross monitoring detectors with remote command

More information

Status of Radiation Safety System at

Status of Radiation Safety System at Status of Radiation Safety System at Taiwan Photon Source Joseph C. Liu Radiation and Operation Safety Division National Synchrotron Radiation Research Center, Taiwan NSRRC layout 1.5 GeV, 120m, 400 ma

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards. 56 / Accessories for inverters Accessories for inverters / Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards. FRONIUS STRING

More information

How To Use A Detector 2

How To Use A Detector 2 Technical Information TI No. WL 80-62 E January 2003 Detector II the mobile phone among the data collectors Maintenance Products Application Condition-based maintenance Principle of operation Application

More information

Radium-223 Therapy: Handling & Radiation Safety Issues

Radium-223 Therapy: Handling & Radiation Safety Issues Nuclear Physics Enterprises Radium-223 Therapy: Handling & Radiation Safety Issues Jeffry A. Siegel, Ph.D. President & CEO 2014 Meeting Mid-Atlantic States Radiation Control Programs Malvern, PA NRC s

More information

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC900300000

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC900300000 Manual EN BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC900300000 Contents EN 1.Important safety instructions... 2 2. Installation... 2 3.Product

More information

Testing of Kaonetics Devices at BNL

Testing of Kaonetics Devices at BNL BNL-95365-2011-IR Testing of Kaonetics Devices at BNL A. Bolotnikov, G. Smith and R. James June 2011 Nonproliferation and National Security Department Brookhaven National Laboratory U.S. Department of

More information

Online Infrared Flue Gas Analyzer Gasboard 3000

Online Infrared Flue Gas Analyzer Gasboard 3000 Online Infrared Flue Gas Analyzer Gasboard 3000 O 2 CO CO2 SO 2 NO NO x Use of measurement methods Proprietary Infrared NDIR Detectors - Micro-flow in ppm range: CO, NO, SO2, CO2 - Dual beam in % volume

More information

Captus 3000 Thyroid Uptake And Well System

Captus 3000 Thyroid Uptake And Well System (201) 825-9500 / (800) 631-3826 THYROID UPTAKE SYSTEMS 49 Captus 3000 Thyroid Uptake And Well System The Ultimate... User Friendly... Intuitive Performing Thyroid Uptake measurements has never been easier.

More information

TMS TANK MANAGEMENT SYSTEM

TMS TANK MANAGEMENT SYSTEM TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS

More information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases

More information

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

SHARKY 775 COMPACT ENERGY METER ULTRASONIC APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic

More information

Continuous, remote monitoring and logging of electromagnetic fields

Continuous, remote monitoring and logging of electromagnetic fields MULTI-BAND EMF AREA MONITOR AMB-8057 Continuous, remote monitoring and logging of electromagnetic fields Discrimination of GSM and UMTS contributions to total emf values Magnetic fields monitoring from

More information

Radiation Sciences Nuclear Medicine Technology Program Hot Lab Log Book (Material)

Radiation Sciences Nuclear Medicine Technology Program Hot Lab Log Book (Material) Radiation Sciences Nuclear Medicine Technology Program Hot Lab Log Book (Material) Table of Content Receiving a Radioactive Package Constancy Test Daily Survey Weekly Wipes Accuracy Test Linearity Geometric

More information

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219 Siemens AG 2010 Flow Measurement Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track)

More information

Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains

Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Drayton Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Invensys Controls Europe Technical Helpline: +44 (0) 845 130 7722 www.draytoncontrols.co.uk Installation

More information

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V 14.5GHZ 2.2KW CW GENERATOR GKP 22KP 14.5GHz WR62 3x400V UTILIZATION OF GKP 22KP GENERATOR With its characteristics of power stability whatever the load, very fast response time at a pulse, low ripple,

More information

Qualitätsmanagement-Handbuch

Qualitätsmanagement-Handbuch U r Kalibrier- und Messmöglichkeiten Qualitätsmanagement-Handbuch Relative erweiterte Messunsicherheit, die sich aus der Standardmessunsicherheit durch Multiplikation mit dem Erweiterungsfaktor k = 2 ergibt.

More information

KR25i HIGH SPEED, HIGH CAPACITY REFRIGERATED CENTRIFUGE AUTO-LOCK. CQCS Traceability System VIDEOset Display!

KR25i HIGH SPEED, HIGH CAPACITY REFRIGERATED CENTRIFUGE AUTO-LOCK. CQCS Traceability System VIDEOset Display! KR25i HIGH SPEED, HIGH CAPACITY REFRIGERATED CENTRIFUGE AUTO-LOCK CQCS Traceability System VIDEOset Display! A CENTRIFUGE FOR ALL YOUR HIGH SPEED APPLICATIONS CLINICAL BIOLOGY, RESEARCH, INDUSTRY The KR25i

More information

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Introduction. Refrigerant Leak Detecting System. Feature and Benefits PSC European Refrigeration Controls Catalogue Catalog Section 9 Product Bulletin PD-GAS-E Refrigerant Leak Detecting System Introduction This range of refrigerant leak detecting systems is designed for

More information

TurbiDirect TurbiCheck TurbiCheck WL

TurbiDirect TurbiCheck TurbiCheck WL Turbidity 128 TurbiDirect TurbiCheck TurbiCheck WL www.lovibond.com General Catalogue February 2013 Turbidity measurement The term "turbidity is used to describe the cloudy or milky appearance of liquid

More information

AN INVESTIGATION INTO THE USEFULNESS OF THE ISOCS MATHEMATICAL EFFICIENCY CALIBRATION FOR LARGE RECTANGULAR 3 x5 x16 NAI DETECTORS

AN INVESTIGATION INTO THE USEFULNESS OF THE ISOCS MATHEMATICAL EFFICIENCY CALIBRATION FOR LARGE RECTANGULAR 3 x5 x16 NAI DETECTORS AN INVESTIGATION INTO THE USEFULNESS OF THE ISOCS MATHEMATICAL EFFICIENCY CALIBRATION FOR LARGE RECTANGULAR 3 x5 x16 NAI DETECTORS Frazier L. Bronson CHP Canberra Industries, Inc. 800 Research Parkway,

More information

Measurement Solutions for Refrigeration Technology.

Measurement Solutions for Refrigeration Technology. Measurement Solutions for Refrigeration Technology. Digital manifold, leak detection, vacuum measurement, and lots more. Testo refrigeration technology Digital is better: Refrigeration technology expertise

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently (68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please

More information

Captus 3000 Thyroid Uptake And Well System

Captus 3000 Thyroid Uptake And Well System (201) 825-9500 / (800) 631-3826 THRYOID UPTAKE SYSTEMS 51 Captus 3000 Thyroid Uptake And Well System The Ultimate... User Friendly... Intuitive Performing Thyroid Uptake measurements has never been easier.

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information