GOOD PRACTICE GUIDE AN INTRODUCTION TO NON-INVASIVE ULTRASONIC FLOW METERING

Size: px
Start display at page:

Download "GOOD PRACTICE GUIDE AN INTRODUCTION TO NON-INVASIVE ULTRASONIC FLOW METERING"

Transcription

1 GOOD PRACTICE GUIDE AN INTRODUCTION TO NON-INVASIVE ULTRASONIC FLOW METERING

2 An introduction to non-invasive ultrasonic flow metering This guide provides an introduction to non-invasive ultrasonic flow metering which is aimed at people who have little experience in this area. It covers the basic concepts of non-invasive ultrasonic flow metering and the advantages it offers before progressing onto the various technological options available. The guide will then highlight the operation of these meters in non-ideal conditions that are often associated with industrial situations. Contents Foreword 2 1 Introduction What is a non-invasive meter? Advantages Transducers Basic hardware configuration 5 2 Theory of Operation Ultrasonic methods Snell s law Transit time Doppler Cross correlation 11 3 Meter Set-up Metering location Pipe preparation Transducer housings Meter diagnostics 15 4 Factors Affecting Performance Flow profile factor Installation effects Entrained gases/solids 19 5 Recent Advancements 20 6 References 20 7 Further Reading 22 1

3 Good Practice Guide Foreword This document is written for those who have little experience in flow measurement but would like to increase their knowledge and understanding in non-invasive ultrasonic flow measurement devices. This guide will describe the advantages and disadvantages of using non-invasive ultrasonic meters and discuss the main principles of operation. It will also detail a few of the most popular measurement techniques available and describe how a final result is calculated. This will assist the reader to choose which meter is the best for their use. The best location to install the meter is discussed and steps to ensure a successful measurement will be detailed in order to give the reader confidence in using a non-invasive ultrasonic flow meter. Some common problems associated with a range of non-ideal process conditions will be addressed. This guide should enable the reader to: Understand the operating principle of each non-invasive device Understand their capabilities Be able to identify good measurement locations Recognise any potential issues that could hinder installation 2

4 An introduction to non-invasive ultrasonic flow metering 1 Introduction 1.1 What is a non-invasive meter? In traditional flow metering, measurement often relies on causing a change in pressure or flow profile in order to derive a volumetric flowrate. For example an orifice plate restricts the diameter through which fluid can flow, typically to about 60% of its original size [1]. This restriction causes a measurable pressure drop which is related to flowrate. The technique works well but suffers from the drawback of an energy penalty caused by the pressure drop. With the drive to utilise more efficient technologies and reduce energy losses, companies are looking towards non-intrusive and non-invasive technology to help save process costs. The difference between invasive and non-invasive and intrusive and non-intrusive is shown in Figure 1 [2]. Figure 1: Sensor position Invasive devices have transducers which come into contact with the flowing fluid. They are also called wetted transducers. Non invasive transducers do not come into contact with the fluid and are placed on the outside of the pipe. Intrusive devices protrude into the flow and distort the flow profile, as can be seen in the top two diagrams. The distortion often leads to mismeasurement by introducing asymmetry to the velocity profile. Different devices can be intrusive but non-invasive or even invasive but non-intrusive. The ultrasonic meters discussed in this guide are both non-intrusive and non-invasive. The reason non-intrusive and especially non-invasive flow meters are so popular is because they do not protrude into the flow, do not come in to contact with fluid and do not generate any pressure losses. 3

5 Good Practice Guide 1.2 Advantages As described previously, these devises are non intrusive and therefore do not interfere with the flow profile [2]. No pressure drop is observed meaning that these devices are more cost effective to operate. They are also non-invasive which means they do not come into contact with the fluid being measured. This is very beneficial when measuring dangerous or corrosive fluids that could damage sensor heads. It also means the transducers can be used alongside heavily fouling fluids and not be affected. This extends the life of the transducers, again saving money. There is no need to break into the pipeline to install these meters which means they can be installed without shutting down the process. This makes them ideal for use on a number of different lines for verification purposes as they are easily portable. There is no chance of leakage or contamination. The turn down ratio is the range at which a meter can operate within its stated uncertainty levels. It is written as a ratio of the highest flow rate in its range compared to the lowest. For a more traditional flow meter such as a differential pressure meter or a turbine meter, the turndown ratio is around 10:1. A non-invasive ultrasonic meter however can have a turndown ratio of up to 400:1. There are no moving parts associated with ultrasonic meters and hence no wear and tear. A turbine meter may have to be maintained in order to achieve peak performance but this is not the case with non-invasive technology. This low maintenance means it will continue to deliver a consistent reading for as long as transducers are working. And even if they fail then they can be easily replaced with new ones without shutting down the process. 1.3 Transducers The transducers are the key element in all ultrasonic technologies and non-invasive devices are no different. They utilise the piezoelectric properties of crystalline, ceramic, composite or polymer film materials which exhibit a special electromechanical quality [3]. The active element in the transducers is a polarised material which has both positive and negative charges throughout. When a current is applied across the material the positive and negative charges align with the electric field which causes the material to change in size and shape; this is called electrostriction. The effect also works in the opposite direction, where an external influence acts on the material and a current is produced. This effect is called piezoelectricity. By utilising this phenomenon, two different transducers can send and receive ultrasonic pulses which can be used to decipher information about a flowing medium. 4

6 An introduction to non-invasive ultrasonic flow metering 1.3 Transducers cont. When a current is applied to a piezoelectric crystal the mechanical energy is produced in the form of vibrations. Tailoring the current can produce vibrations of a chosen frequency and this is the basis for all ultrasonic flow metering; including non-invasive and in-line meters. Figure 2 shows a piezoelectric crystal in operation. Figure 2: Mechanical movement produced from an electric current in a piezoelectric crystal 1.4 Basic hardware configuration All ultrasonic technologies follow the same basic hardware configuration for measurement. Figure 3 shows this configuration and the key components used: System Control, Excitation Electronics, Transducers, Reception Electronics, Signal Processing and Data Output [2]. Figure 3: A generalised ultrasonic meter configuration A control system is in place to ensure the process runs smoothly and the transmitted and received signals are processed properly. The control system initiates the excitation electronics to emit an ultrasonic sound wave from the transmitting transducer. The receiving transducer then detects the signal and converts the sound energy into electrical signals that are passed to the reception electronics. The signal is then processed to extract the data and an output either stores the data internally within the module memory or communicates it out in real time. 5

7 Good Practice Guide 1.4 Basic hardware configuration cont. All technologies use a similar system to this model but differ in transducer material, signal processing techniques and system control. These differences are usually proprietary to each manufacturer. Another difference in meter configurations is with the signal emitted by the transmitting transducer. Three types of signal are mainly used and each can be of benefit in different process situations. Types of current signal include: 1. Pulse 2. Tone burst 3. Coded burst As can be seen in Figure 3, there are distinct differences between each signal. 2 Theory of Operation 2.1 Ultrasonic methods There are several different ways that ultrasonic signals can be utilised to calculate flow rate [2, 4]. Figure 4 shows five different non-invasive methods that can be used. Figure 4: Modes of ultrasonic operation Passive acoustics is a technique where the transducer simply listens to the naturally occurring vortices or eddies in the flow. By monitoring how fast they flow by the transducer, a velocity can be derived. Beam deflection works by transmitting an ultrasonic beam across the pipe which is slightly deflected by the flow. This deflection is monitored and is directly related to the velocity of the flowing medium. The three main types of non-invasive ultrasonic technology currently used are Transit time Doppler Cross correlation These will be described in more detail later in this section. 6

8 An introduction to non-invasive ultrasonic flow metering 2.2 Snell s law As nearly all of ultrasonic metering techniques rely heavily on knowing the angle of incidence of the ultrasonic beam, it is imperative that this value be as accurate as possible. This becomes even more important in non-invasive or externally mounted devices. As an ultrasound beam passes between two acoustically different media, the sound wave is refracted. This means the angle at which the beam was first emitted will not be the same as the angle that enters the flow. In externally mounted transducer housings there are three distinct media that the ultrasound must pass through in order to emit or receive a signal. These are shown in Figure 5. Figure 5: Ultrasonic beam refracting at interfaces This poses the problem of trying to match the spacing of the transducers to ensure the strongest signal is received. How do you know which angle the ultrasonic beam is propagating at? This problem can be solved by the use of Snell s law [5] that states that the angle of incidence of the sound wave divided by the speed of sound in that medium is constant for all materials. Referring to Figure 5: = = As the transducer angle, and the transducer velocity of sound (VoS) will be known, the ultrasonic beam propagation angle through the flowing fluid can be calculated. This is used to determine transducer spacing and other important configuration parameters. 2.3 Transit time This is the most common type of clamp on technology and can be used for both gases and liquids. The principle is based on the time difference it takes for an ultrasonic pulse to travel a defined distance both with and against flow. The difference is directly related to the velocity of the flow and is to some extent analogous to a boat crossing a river. If the boat is travelling with the current then it will be helped across to some degree by the flowing fluid but the opposite is true when travelling against the current. 7

9 Good Practice Guide 2.3 Transit time cont. This means that time taken for an ultrasonic beam to travel across a pipe is not only dependent on the VoS in that medium but also on the velocity of the actual flowing fluid itself. The equations below show how a velocity can be derived from transit time measurements. Figure 6a: Oppositely placed transducers Figure 6b: Adjacently placed transducers Figure 6a is normally referred to as direct mode i.e. the ultrasonic beam only makes one traverse across the pipe. Figure 6b is normally referred to as reflect mode as two traverses are required [6]. A stronger signal is achieved in direct mode but reflect mode is more accurate. Only direct mode shall be considered in more detail. As shown in Figure 6a transducer A transmits an ultrasonic pulse across a pipeline at an angle, θ, which is received by transducer B. As the VoS for the flowing medium and the length the ultrasound travels are both known a simple equation can be used to calculate the time taken for the ultrasonic signal to reach the receiving transducer. This is also known as the time of flight of the ultrasonic signal [6, 7]. = + Where tab is the time taken to for the ultrasound to go from transducer A to transducer B, L is the distance travelled by the ultrasound, VoS is the velocity of sound in the fluid, Vf is the fluid velocity and θ is the angle the ultrasound propagates through the fluid. 8

10 An introduction to non-invasive ultrasonic flow metering 2.3 Transit time cont. Transducer B now emits an ultrasonic pulse that travels across the pipe line to be received by transducer A. Again the time of flight can be found by using the following equation. = Where tba is the time taken to for the ultrasound to go from transducer B to transducer A. Notice, the fluid velocity is acting against the ultrasonic signal as it is travelling against the flow. Both waveforms are shown in Figure 7. Figure 7: Transit time waveforms To get the transit time difference, t, between these two waveforms, one traverse time is simply subtracted from the other one. = = + Combining and rearranging for vf gives: = 2 It is important to note that the equation to calculate velocity is independent of the VoS of the fluid and that the only measurement taken is time. To calculate the volumetric flowrate, this velocity is simply multiplied by the cross sectional area of the pipe. The equation below shows the calculation for volumetric flowrate: = 4 = 8 This equation assumes the velocity recorded for the ultrasonic path is representative of the entire pipe cross section. This may not be the case however due to non-uniform flow profiles and flow disturbances. To correct for these conditions, profile correction factors and multiple paths can be used. 9

11 Good Practice Guide 2.4 Doppler Doppler non-invasive ultrasonic flow meters are based on the well known Doppler principle and frequency shifts in the ultrasonic signal. From a stationary source, a sound wave will reach a stationary observer with the same frequency as it was emitted. Consider now a moving source and a stationary observer. As each sound wave is emitted the source moves further away meaning there is a larger distance for the next sound wave to travel before it reaches the observer. As the sound velocity will be the same, it will be the time between each wave that will increase and therefore the frequency will be shifted. The effect can be heard in everyday life by the siren of a passing emergency vehicle. The frequency of the siren is high pitch as it comes towards you but becomes lower as it passes and drives away. Figure 8 below shows the Doppler Effect schematically: Figure 8: The Doppler Effect In flow measurement, again two transducers are used and are often placed on the same side of the pipe. Most Doppler techniques require a small amount of gas or entrained solids in the flow in order to calculate a velocity [6]. Transducer A emits an ultrasonic beam of a known frequency. This beam reflects off either the gas bubbles or solids within the flow and is frequency shifted. Transducer B then receives the frequency shifted ultrasonic signal and by measuring the change can derive a velocity. Figure 9 shows the transducers and ultrasonic signal in operation. Figure 9: Doppler ultrasonic meter 10

12 An introduction to non-invasive ultrasonic flow metering 2.4 Doppler cont. The velocity is directly proportional to the change in frequency and is shown below [6, 8]: = = + Where ft is the transmitted frequency, fr is the received frequency, vf is the velocity of the reflection particle and θt and θr are the transmission and receiving angles of the ultrasonic signal which are predetermined by the meter manufacturer. As the transducers are on the outside of the pipe then Snell s law can be used to make the calculation independent of fluid and wall acoustic properties. = + Where, is the transmitted beam angle in the transmitting transducer and is the receiving beam angle in the receiving transducer. Manufacturers will use the same material for each transducer and therefore the VoS will be the same. Normally, the propagation angle of the ultrasonic beam will be set up to be the same for both transducers meaning the equation simplifies to: = 2 = 2 Again, multiplying by the cross sectional area of the pipe will give volumetric flowrate. 2.5 Cross correlation In this technique, two pairs of transducers are positioned on a pipe with both receivers and both transmitters on the same side of the pipe respectively. The transducer pairs are placed in the same plane in order to maximise the potential for correlating signals [9]. The main difference between transit time and cross correlation flow meters is that one transducer is always the transmitter and one transducer is always the receiver; they do not swap. Figure 10 shows the transducer configurations: Figure 10: Cross correlation flow meter 11

13 Good Practice Guide 2.5 Cross correlation cont. Both the upstream and downstream transducers transmit an ultrasonic pulse across the pipe that is modulated by naturally occurring eddies or vortices in the flow. The result is two very similar waveforms (Figure 11) that have distinctive peaks which are displaced by a time factor. This time factor is directly proportional to the distance between the pairs of transducers and inversely proportional to the flow velocity. Figure 11: Cross correlation waveforms received To calculate the time difference a mathematical cross correlation function is used. (, )= 1 ( + ) ( ) Where y(t) is the downstream signal (blue in Figure 11), ( + ) is the upstream signal delayed by time (red in Figure 11), T is the integration time and I is the distance between the pairs of transducers. 3 Meter Set-up Non-invasive ultrasonic meters are extremely sensitive to any variations in propagation angles and transducer spacing. This means that during set-up, care has to be taken to ensure the measurements are as accurate as possible. The same procedures for set up can be applied to all non-invasive ultrasonic technologies as it is only the actual measurement and processing techniques that vary. 12

14 An introduction to non-invasive ultrasonic flow metering 3.1 Metering location The first step in any metering process is to select a suitable location for measurement. Ultrasonic flow meters are heavily influenced by changes in flow profile caused by flow disturbances and this has to be taken into consideration when choosing a measurement location. Each meter manufacturer has its own guidelines on what distances from a disturbance to place a meter in order to achieve a good measurement. This information can be found in manuals and technical specifications. Typical distances from a flow disturbance can be found in Table 1. Table 1: Typical distances from a flow disturbance Disturbance Downstream (D) Upstream (D) Single elbow 10 5 Double elbow in plane 25 5 Double elbow out of plane 40 5 T-piece Diffuser 30 5 Valve Reducer 10 5 Pump 50 Other key points to note when choosing a metering location are to ensure that there is no chance of: The pipe becoming partially or completely empty Material deposits on the inside diameter of the pipe interfering with the signal Gas bubbles interfering with the signal Liquid/gas accumulation These conditions can occur when measuring flow in vertical pipes or pipe configurations that have natural low or high points that allow for liquid or gas pooling. 3.2 Pipe preparation Once a suitable location on the pipe has been found, the pipe then has to be prepared in order to ensure a high quality signal can be sent between the transducers. As discussed, each material has different acoustic impedances which restrict the amount of sound energy that can be passed between them. In order to maximise the energy passed through the interface of the two materials a good contact has to be achieved. In normal industrial applications, there is a good chance that a pipe will exhibit some rust or have paint or scratches leaving an uneven surface. Also, with natural manufacturing processes it is likely there will be an element of roughness to the surface of the pipe. The pipe therefore will have to be smoothed down and cleaned up. This can be done using some emery cloth and tissues. It is best to use the emery cloth in an axial motion along the pipe instead of radially around the pipe as this is parallel to the direction the ultrasound will travel. Once the rust or paint is removed and a smooth finish has been made the next step in the set-up involves taking measurements of the pipe wall thickness and diameter. This can be estimated using pipe schedule information but it is recommended to take readings at the measurement location as there can be variations in pipe wall thickness and diameter at the manufacturing stage. 13

15 Good Practice Guide 3.2 Pipe preparation cont. Normally a pi tape is used to give outside diameter but other instruments can be used as long as they are reasonably accurate. Manufacturers often sell pipe wall measurement devices alongside their meter and an average of several points around the test position should be used. 3.3 Transducer housings Once the outside pipe diameter and wall thickness are known, they can be entered into the flow computer alongside the fluid type and temperature etc. This information is then used to calculate the transducer spacing required for measurement. If transducer housings are supplied then they should be installed on the pipe at this stage by following the manufacturer s instruction manual. It is often recommended that two people complete the installation but it can usually be completed by one. Figure 12 shows a typical housing set up with transducers attached. Figure 12: Typical clamping mechanism for transducer housings In order to combat issues such as solids formation on the bottom of the pipe or gas bubbles at the top, it is recommended to attach the housings in the horizontal position if only one pair of transducers are being used. Figure 13 shows the correct positions of transducers for a single pair of transducers in reflect mode. Figure 13: Transducer positions for single pair of transducers 14

16 An introduction to non-invasive ultrasonic flow metering 3.3 Transducer housings cont. If using two pairs of transducers however they should form an X configuration in the pipe. Two pairs of transducers will be more accurate as they can handle disturbances in the flow better. Figure 14 shows the correct installation. Figure 14: Transducer positions for 2 pairs of transducers To improve installation of the system, first locate and secure the transducer housings. After the transducers have been housed, tighten all the associated fasteners. Now, the housings should be in the correct place with the correct transducer spacing. The flow computer also has all the information it requires for measurement. Carefully apply the transducer couplant gel to the middle of the transducer base in a thin, line along the length. This couplant is used to ensure reflections are not received from the pipe wall and that any imperfections in the pipe smoothness can be minimised. Insert the transducers into the housing and tighten. The couplant should spread out along the transducer base and allow for full contact with the pipe wall. Again manufacturers have different couplants and use different techniques to apply it. You should always consult the manufacturer s instruction manual when in doubt. 3.4 Meter diagnostics The transducer should now be installed on the pipe. Ensure all housings and transducers are tight and will not move with any pipe vibrations. The next step before taking the measurement is to ensure you have confidence in the reading. The diagnostics of the ultrasonic meter must be checked to make sure they are within the stated limits [10]. Typically the Signal to Noise Ratio (SNR) should be above a minimum of 20 but a target of 30 or 40 should be achieved [11]. The SNR is a measure of the signal strength received compared against the background (random) noise picked up. If these two values are not significantly different then a correct measurement can not be made. SNR can be calculated by using the equation below: =2 0 The VoS is an important factor in clamp-on technology. As the VoS is not measured directly but instead inferred from the transit time of the ultrasonic wave and knowledge of the distance between the transducers, it can be used as a check to see if the meter is working properly. Most meters have a built in table listing the VoS of different media and so by comparing this measured value against the value in the table, the meter can be checked to see if the values are similar [11]. If the values are different by a predetermined amount, then the diagnostics will alert the user to the problem. 15

17 Good Practice Guide 4 Factors Affecting Performance 4.1 Flow profile factor Fluids can flow along a pipe in two very distinctive ways. Which flow is present is dependent on the viscosity, density and velocity of the fluid but also on the diameter of the pipe. These parameters can be combined to form a dimensionless function called Reynolds number. It is a measure of the viscous forces against the inertial forces and depending on which one is dominant, defines the way the fluid flows along the pipe. When viscous forces are dominant and Reynolds numbers are <2000 then laminar flow is present. Laminar flow can be similar to a busy motorway; cars travel along at various speeds rarely changing their lanes. In relation to flow in a pipe, the slow lane would be at the pipe wall and fast lane in the centre. When inertial forces are dominant and Reynolds numbers are >4000 then turbulent flow is present. Turbulent flow can be similar to a flock of birds or school of fish. Whereas the collective group are all heading in the same direction, each individual will move unpredictably through the mass; veering up, down, left and right. The flow is no longer moving parallel to each other but mixing up and, as the name suggests, becoming turbulent. With Reynolds numbers between 2000 and 4000, the flow is unclassified and either of the flows can be present or indeed a mixture of the two. This is called the transition region and it is always best to avoid measurement in this region as it is too unpredictable. Both laminar and turbulent flows have different effects on the velocity at different points on the cross section of the pipe. Laminar flow tends towards a peaked flow profile but turbulent has a flatter profile as shown in Figure 15. In all non-invasive ultrasonic technologies only diametric paths are used because of the position of the transducers. This means that the signal is only taking an average of the diameter of the pipe directly through the middle. When looking at the flow profile for fully developed flow this means that an ultrasonic meter will over-read the velocity of the flowing fluid [2]. Figure 15 shows the over-reads with respect to flow profile. 1 1 V diameter 0.8 V diameter 0.8 V mean V mean Figure 15: Diametric and mean velocities for laminar and turbulent flow profiles 16

18 An introduction to non-invasive ultrasonic flow metering 4.1 Flow profile factor cont. In the laminar region (Re < 2000) a rounded or peaked profile is present with faster moving fluid in the centre. As the ultrasonic meter averages out the velocity on this diameter it has a large over-reading that is not representative of the mean velocity. The same is true for fluids in the turbulent region except that the over-read is not as high. In order to combat this, a flow profile correction factor is introduced, kh. This correction factor is simply to correct the measured velocity to the mean flow velocity and is calculated by the following equation: = Typically kh has a value of 0.76 for laminar flow and 0.94 for turbulent flow [2]. In Figure 16 the turbulent kh factor is plotted as a function of flow velocity for three values of pipe diameter and two fluid viscosities. The functional shape is almost independent of pipe size and relatively linear with fluid velocity, except at very low values. It is also apparent that any (uncompensated) changes in viscosity can have the capacity to introduce additional errors of the order of a few tenths of a per cent. 4.2 Installation effects Figure 16: Diametric profile factor expressed as a function flow velocity On a calibrated flow facility, manufacturer s claims of ± 2% uncertainty are achievable but in industrial situations nonstandard conditions are usually present and therefore typical uncertainties are in the region of ± 5%. This is due to disturbances in the flow such as bends, valves and pipe sizes that all cause changes to the flow profile [12]. Examples of disturbances can be found in Figure 17. Figure 17: Examples of flow disturbances 17

19 Good Practice Guide 4.2 Installation effects cont. Figures 18a and 18b show a computational fluid dynamic (CFD) representation of a fully developed and a highly disturbed flow profile respectively with a pair of ultrasonic transducers attached. Figure 18a: Fully developed flow profile Figure 18b: Disturbed flow profile In a fully developed flow profile (Figure 18a) the measurement path takes account of all the velocities in the pipe from pipe wall to centre. This gives an accurate representation of the flow velocity once the flow profile correction is applied. For the disturbed flow however there is a large high velocity region on the right hand side which the measurement path barely cuts through. This means this high velocity region is not properly represented in the measured velocity and so the meter will under-read [13, 14]. 18

20 An introduction to non-invasive ultrasonic flow metering 4.2 Installation effects cont. Flow profiles will all eventually become fully developed like Figure 18a but this happens over substantial settling lengths. Manufacturers will always state a required distance from a disturbance before reliable flow measurement can be achieved and wherever possible this should be adhered to. Examples have been shown previously in Table Entrained gases/solids Another common issue with process fluids is the presence of another phase within the flow. This could be caused by either entrained solids in the system such as sand, or entrained gas from cavitation or flashing. The effect of either or both of these problems is quite similar and can cause the ultrasonic meter to over-read the fluid velocity. As an ultrasonic meter derives the volumetric flowrate of liquid across a diameter, any value it measures will be assumed to be for a single phase fluid. In reality however, a small percentage of the flow will be either solids or gas therefore reducing the volume of liquid present. The meter will therefore misread the amount of liquid flowing through the pipe. Higher solids content or gas volume fractions (GVFs) are directly related to larger errors associated with measurement. Another problem related to the presence of another phase is the attenuation of the ultrasonic signal. As the beam travels through the pipe it will reflect and be absorbed by the second phase [6, 15]. This reduces the strength of the signal received by the receiving transducer and therefore the signal quality. The SNR will reduce and with it any confidence in an accurate measurement. Figure 19 shows the relationship between total volume error (blue) and SNR (red) with GVF. These results are for a velocity of 5 m/s. Figure 19: Effect of GVF on total volume error and SNR 19

21 Good Practice Guide 5 Recent Advancements In previous years it has widely been regarded that anything above 2% gas or solids in a system would cause ultrasonic flow meters to stop giving a sensible value for the flow rate but in recent years there has been an advance in technology and processing ability so that meters can still maintain a reading well over 10%. This has provided an opportunity for non-invasive ultrasonic metering to be applied in a wider field of measurement involving 2-phase flow. Manufacturer s websites and conferences can give more information about the application range of particular devices and these should be sought for further information. From recent work carried out at TUV NEL, the uncertainty associated with non-invasive ultrasonic flow meters after a flow disturbance has been reduced significantly. Extensive test work and CFD modelling have been used to create correction factors that can reduce errors by a several per cent in some cases. TUV NEL has also developed specific cluster configurations that use multiple paths of non-invasive flow meters to reduce the error further. 6 References 1. Good Practice Guide on Differential Pressure Meters. TUV NEL Ltd, 2. Training Course on Ultrasonic Meters. TUV NEL Ltd, 3. Application of MEMS Ultrasonic Transducers to Flow Measurement A Technical Review. Report 2007/76. TUV NEL Ltd, East Kilbride, Glasgow 4. Sanderson M.L. Guidelines for the use of Ultrasonic Non-invasive Metering Techniques. Flow Measurement and Instrumentation 13, 2002 Pages BS 8452:2005 Use of Clamp-on (externally mounted) Transit Time Metering Techniques for Liquid Applications 7. Final Report on Clamp-on Transit Time Ultrasonic Flow Meter Performance Evaluation. Project FEUS05 of DTI NMSD Flow Programme, Sira. October T. Cousins. The Doppler Ultrasonic Flow Meter. Proceedings of Flomeko 78, Groningen, the Netherlands, September J.K. Sidney, N.W. King and J. Coulthard. Cross-correlation Flow Measurements in Oil-air Mixtures. Proceedings of the IMEKO XI World Congress, Houston, Texas, J. Lansing. Smart Monitoring and Diagnostics for Ultrasonic Gas Meters. North Sea Flow Measurement Workshop (2000). 11. Manufacturer Presentation, Clamp-on Diagnostics Good Practice Guide on Installation Effects. TUV NEL Ltd, Velocity Distribution Effects on Ultrasonic Flow Meters, Part 1. Report 348/99. TUV NEL Ltd, East Kilbride, Glasgow 14. Velocity Distribution Effects on Ultrasonic Flow Meters, Part 2. Report 348/99. TUV NEL Ltd, East Kilbride, Glasgow 15. G.J. Brown, Factors Affecting the Performance of Ultrasonic Flow Meters, Proceedings of the North Sea Flow Measurement Workshop, Kristiansand, Norway, October

22 An introduction to non-invasive ultrasonic flow metering 7 Further Reading Any standard on ultrasonic meters are excellent sources for information and should be consulted. The BS 8452:2005 Use of clamp-on (externally mounted) transit time metering techniques for liquid applications and the ISO/FDIS :2008 Measurement of fluid flow in closed conduits Ultrasonic meters for gas Part 1: meters for custody transfer and allocation measurements. will answer any questions. For further information, contact: TUV NEL, East Kilbride, GLASGOW, G75 0QF, UK Tel: + 44 (0) info@tuvnel.com

23

Laminar and Turbulent flow. Flow Sensors. Reynolds Number. Thermal flow Sensor. Flow and Flow rate. R = Mass Flow controllers

Laminar and Turbulent flow. Flow Sensors. Reynolds Number. Thermal flow Sensor. Flow and Flow rate. R = Mass Flow controllers Flow and Flow rate. Laminar and Turbulent flow Laminar flow: smooth, orderly and regular Mechanical sensors have inertia, which can integrate out small variations due to turbulence Turbulent flow: chaotic

More information

HEAVY OIL FLOW MEASUREMENT CHALLENGES

HEAVY OIL FLOW MEASUREMENT CHALLENGES HEAVY OIL FLOW MEASUREMENT CHALLENGES 1 INTRODUCTION The vast majority of the world s remaining oil reserves are categorised as heavy / unconventional oils (high viscosity). Due to diminishing conventional

More information

Grant Agreement No. 228296 SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

Grant Agreement No. 228296 SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme Grant Agreement No. 228296 SFERA Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME Capacities Specific Programme Research Infrastructures Integrating Activity - Combination of

More information

Energy and Flow Measurement for Hydronic Systems

Energy and Flow Measurement for Hydronic Systems Energy and Flow Measurement for Hydronic Systems Presented By: George Szyszko Applications Consultant MCR for ONICON Incorporated Why Measure Thermal Energy? To control something, you must first measure

More information

BIOMEDICAL ULTRASOUND

BIOMEDICAL ULTRASOUND BIOMEDICAL ULTRASOUND Goals: To become familiar with: Ultrasound wave Wave propagation and Scattering Mechanisms of Tissue Damage Biomedical Ultrasound Transducers Biomedical Ultrasound Imaging Ultrasonic

More information

Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any

Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any Chapter 10 Flow Measurements Material from Theory and Design for Mechanical Measurements; Figliola, Third Edition Flow Rate Flow rate can be expressed in terms of volume flow rate (volume/time) or mass

More information

CHALLENGES FOR ULTRASONIC FLOW METERS IN WET GAS APPLICATIONS

CHALLENGES FOR ULTRASONIC FLOW METERS IN WET GAS APPLICATIONS CHALLENGES FOR ULTRASONIC FLOW METERS IN WET GAS APPLICATIONS Bernhard Funck, Peter Baldwin FLEXIM GmbH, Berlin, Germany Norwegian distributer: Flow-Teknikk as, see http://www.flow.no 1 ABSTRACT Accurate

More information

Flow Measurement Options for Pipeline and Open Channel Flow

Flow Measurement Options for Pipeline and Open Channel Flow Flow Measurement Options for Pipeline and Open Channel Flow October 2013 Presented by Molly Skorpik - 2013 Montana Association of Dam and Canal Systems Conference Irrigation Training and Research Center

More information

FLUID FLOW STREAMLINE LAMINAR FLOW TURBULENT FLOW REYNOLDS NUMBER

FLUID FLOW STREAMLINE LAMINAR FLOW TURBULENT FLOW REYNOLDS NUMBER VISUAL PHYSICS School of Physics University of Sydney Australia FLUID FLOW STREAMLINE LAMINAR FLOW TURBULENT FLOW REYNOLDS NUMBER? What type of fluid flow is observed? The above pictures show how the effect

More information

NEW DEVELOPMENTS IN FLOW AND PIPE MANAGEMENT CAPABILITIES THROUGH NEW VELOCITY PROFILE MEASUREMENT AND PIPE WALL WEAR MONITORING INSTRUMENTATION

NEW DEVELOPMENTS IN FLOW AND PIPE MANAGEMENT CAPABILITIES THROUGH NEW VELOCITY PROFILE MEASUREMENT AND PIPE WALL WEAR MONITORING INSTRUMENTATION NEW DEVELOPMENTS IN FLOW AND PIPE MANAGEMENT CAPABILITIES THROUGH NEW VELOCITY PROFILE MEASUREMENT AND PIPE WALL WEAR MONITORING INSTRUMENTATION Christian O Keefe, CiDRA Minerals Processing, Inc., Wallingford,

More information

THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT

THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT Kazuto Otakane, Tokyo Gas Co., Ltd Katsuhito Sakai, Tokyo Gas Co., Ltd Minoru Seto, Tokyo Gas Co., Ltd 1. INTRODUCTION Tokyo Gas s new gas meter,

More information

PIPELINE INSPECTION UTILIZING ULTRASOUND TECHNOLOGY: ON THE ISSUE OF RESOLUTION By, M. Beller, NDT Systems & Services AG, Stutensee, Germany

PIPELINE INSPECTION UTILIZING ULTRASOUND TECHNOLOGY: ON THE ISSUE OF RESOLUTION By, M. Beller, NDT Systems & Services AG, Stutensee, Germany ABSTRACT: PIPELINE INSPECTION UTILIZING ULTRASOUND TECHNOLOGY: ON THE ISSUE OF RESOLUTION By, M. Beller, NDT Systems & Services AG, Stutensee, Germany Today, in-line inspection tools are used routinely

More information

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology HWEA 2011 Conference Craig S. Johnson Presentation Overview Introduction Aeration Air & Digester gas challenges Gas flow metering

More information

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids Non-invasive CLAMP-ON ultrasonic flowmeter for liquids Model CU100: non-invasive installation flowmeter, with transducers installed outside the pipe Installation in horizontal or vertical pipe Easy and

More information

PORTABLE FLOW METER KITS TDS-100H

PORTABLE FLOW METER KITS TDS-100H Transit Time Flow Meters TT-TDS-100H-HS ECEFast offers amazing prices on Transit Time Flow Meter portable kits. We are buying from the manufacturer who supplies 60% of the Chinese market and the majority

More information

CALDON LEFM 380Ci Gas Ultrasonic Flow Meter. Integrating experience, proven technology and innovation

CALDON LEFM 380Ci Gas Ultrasonic Flow Meter. Integrating experience, proven technology and innovation CALDON LEFM 380Ci Gas Ultrasonic Flow Meter Integrating experience, proven technology and innovation VALVES & MEASUREMENT Cameron s CALDON LEFM 380Ci gas ultrasonic flow meter combines world-leading flow

More information

Synthetic Sensing: Proximity / Distance Sensors

Synthetic Sensing: Proximity / Distance Sensors Synthetic Sensing: Proximity / Distance Sensors MediaRobotics Lab, February 2010 Proximity detection is dependent on the object of interest. One size does not fit all For non-contact distance measurement,

More information

Liquid Flowmeters A Guide for Selecting a Flowmeter for Pressurized Systems

Liquid Flowmeters A Guide for Selecting a Flowmeter for Pressurized Systems Liquid Flowmeters A Guide for Selecting a Flowmeter for Pressurized Systems Selecting a meter requires a first-rate technical assessment of the pressurized system and a thorough evaluation of the capabilities

More information

Field Trials and Pragmatic Development of SONAR Flow Meter Technology. Bill Pearson, BP AGT and Nigel Webster, Expro

Field Trials and Pragmatic Development of SONAR Flow Meter Technology. Bill Pearson, BP AGT and Nigel Webster, Expro Field Trials and Pragmatic Development of SONAR Flow Meter Technology by Bill Pearson, BP AGT and Nigel Webster, Expro Meters Inc. Contents Requirement for retrospective fit, non-intrusive measurement

More information

191: Calibration and Standards in Flow Measurement. Richard Paton National Engineering Laboratory, Scotland, UK 1 GENERAL PRINCIPLES

191: Calibration and Standards in Flow Measurement. Richard Paton National Engineering Laboratory, Scotland, UK 1 GENERAL PRINCIPLES 191: Calibration and Standards in Measurement Richard Paton National Engineering Laboratory, Scotland, UK 1 General Principles 1 2 Gravimetric Calibration of Liquid meters 2 3 Volumetric Calibration of

More information

Flow Assurance & Operability

Flow Assurance & Operability Flow Assurance & Operability Erosion due to sand production Date Business Name Overview 1. What causes erosion? 2. Sand production and transport 3. Sand management 4. Instrumentation / monitoring of sand

More information

Robot Perception Continued

Robot Perception Continued Robot Perception Continued 1 Visual Perception Visual Odometry Reconstruction Recognition CS 685 11 Range Sensing strategies Active range sensors Ultrasound Laser range sensor Slides adopted from Siegwart

More information

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours) INSURANCE SCAM OPTICS - LABORATORY INVESTIGATION P R E A M B L E The original form of the problem is an Experimental Group Research Project, undertaken by students organised into small groups working as

More information

FLOW METER SPECIFICATION AND APPLICATION ANALYSIS Class #41

FLOW METER SPECIFICATION AND APPLICATION ANALYSIS Class #41 FLOW METER SPECIFICATION AND APPLICATION ANALYSIS Class #41 Curtis Gulaga Business Development Manager CB Engineering Ltd. #20, 5920 11 th Street SE Calgary, AB T2H 2M4 1.0 Introduction Today s working

More information

Instruction Manual Service Program ULTRA-PROG-IR

Instruction Manual Service Program ULTRA-PROG-IR Instruction Manual Service Program ULTRA-PROG-IR Parameterizing Software for Ultrasonic Sensors with Infrared Interface Contents 1 Installation of the Software ULTRA-PROG-IR... 4 1.1 System Requirements...

More information

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids Dr. J. M. Meyers Dr. D. G. Fletcher Dr. Y. Dubief 1. Introduction Last lab you investigated flow loss in a pipe due to the roughness

More information

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc. ASGMT / Averaging Pitot Tube Flow Measurement Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc. Averaging Pitot Tube Meters Introduction

More information

E190Q Lecture 5 Autonomous Robot Navigation

E190Q Lecture 5 Autonomous Robot Navigation E190Q Lecture 5 Autonomous Robot Navigation Instructor: Chris Clark Semester: Spring 2014 1 Figures courtesy of Siegwart & Nourbakhsh Control Structures Planning Based Control Prior Knowledge Operator

More information

4.What is the appropriate dimensionless parameter to use in comparing flow types? YOUR ANSWER: The Reynolds Number, Re.

4.What is the appropriate dimensionless parameter to use in comparing flow types? YOUR ANSWER: The Reynolds Number, Re. CHAPTER 08 1. What is most likely to be the main driving force in pipe flow? A. Gravity B. A pressure gradient C. Vacuum 2.What is a general description of the flow rate in laminar flow? A. Small B. Large

More information

Physical Science Study Guide Unit 7 Wave properties and behaviors, electromagnetic spectrum, Doppler Effect

Physical Science Study Guide Unit 7 Wave properties and behaviors, electromagnetic spectrum, Doppler Effect Objectives: PS-7.1 Physical Science Study Guide Unit 7 Wave properties and behaviors, electromagnetic spectrum, Doppler Effect Illustrate ways that the energy of waves is transferred by interaction with

More information

PAGE 2. Figure 1: Difference between PWL ins and SPL 1m

PAGE 2. Figure 1: Difference between PWL ins and SPL 1m PAGE 1 Pipe noise J.H. Granneman and R.P.M. Jansen, Peutz Consulting Engineers, The Netherlands, emphasise the need for an adequate pipe noise control procedure, with reference to the design phase, insulation

More information

Advanced Differential Pressure Flowmeter Technology V-CONE FLOW METER TECHNICAL BRIEF

Advanced Differential Pressure Flowmeter Technology V-CONE FLOW METER TECHNICAL BRIEF Advanced Differential Pressure Flowmeter Technology V-CONE FLOW METER TECHNICAL BRIEF Table of Contents Section 1 - General Introduction 1.1 1 Principles Of Operation 1.2 1 Reshaping The Velocity Profile

More information

Copyright 2008 Pearson Education, Inc., publishing as Pearson Addison-Wesley.

Copyright 2008 Pearson Education, Inc., publishing as Pearson Addison-Wesley. Chapter 20. Traveling Waves You may not realize it, but you are surrounded by waves. The waviness of a water wave is readily apparent, from the ripples on a pond to ocean waves large enough to surf. It

More information

1-4 kg/m3. Long in-line calibration cycles of the gamma density systems may improve measurement accuracy, but this is often not practical subsea.

1-4 kg/m3. Long in-line calibration cycles of the gamma density systems may improve measurement accuracy, but this is often not practical subsea. Generating Greater Accuracy and Robustness from Subsea Multiphase Meters By Finn Erik Berge, Emerson Process Management Subsea multiphase meters have faced a growing number of challenges linked to the

More information

Various Technics of Liquids and Solids Level Measurements. (Part 3)

Various Technics of Liquids and Solids Level Measurements. (Part 3) (Part 3) In part one of this series of articles, level measurement using a floating system was discusses and the instruments were recommended for each application. In the second part of these articles,

More information

THE RELEVANCE OF TWO DIFFERENT PATH LAYOUTS FOR DIAGNOSTIC PURPOSES IN ONE ULTRASONIC METER

THE RELEVANCE OF TWO DIFFERENT PATH LAYOUTS FOR DIAGNOSTIC PURPOSES IN ONE ULTRASONIC METER THE RELEVANCE OF TWO DIFFERENT PATH LAYOUTS FOR DIAGNOSTIC PURPOSES IN ONE ULTRASONIC METER MR. JOHN LANSING, SICK MAIHAK, Houston, Texas DR. VOLKER HERRMANN, SICK MAIHAK, Dresden, Germany MR. TORALF DIETZ,

More information

Lesson 11. Luis Anchordoqui. Physics 168. Tuesday, December 8, 15

Lesson 11. Luis Anchordoqui. Physics 168. Tuesday, December 8, 15 Lesson 11 Physics 168 1 Oscillations and Waves 2 Simple harmonic motion If an object vibrates or oscillates back and forth over same path each cycle taking same amount of time motion is called periodic

More information

Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19

Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19 Doppler Doppler Chapter 19 A moving train with a trumpet player holding the same tone for a very long time travels from your left to your right. The tone changes relative the motion of you (receiver) and

More information

Index-Velocity Rating Development (Calibration) for H-ADCP Real-Time Discharge Monitoring in Open Channels

Index-Velocity Rating Development (Calibration) for H-ADCP Real-Time Discharge Monitoring in Open Channels Index-Velocity Rating Development (Calibration) for H-ADCP Real-Time Discharge Monitoring in Open Channels Hening Huang Teledyne RD Instruments, Inc., 14020 Stowe Drive, Poway, CA. 92064, USA (Tel: 858-842-2600,

More information

The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions

The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions The Versatile Differential Pressure Transmitter By David Gunn Honeywell Process Solutions The Versatile Differential Pressure Transmitter 2 Table of Contents Abstract... 3 Pressure Fundamentals... 3 Applications...

More information

Chapter 13 OPEN-CHANNEL FLOW

Chapter 13 OPEN-CHANNEL FLOW Fluid Mechanics: Fundamentals and Applications, 2nd Edition Yunus A. Cengel, John M. Cimbala McGraw-Hill, 2010 Lecture slides by Mehmet Kanoglu Copyright The McGraw-Hill Companies, Inc. Permission required

More information

Easily installed and simple to set up, Flow Pulse uses an acoustic technique never before seen in flow measurement to deliver reliable results across

Easily installed and simple to set up, Flow Pulse uses an acoustic technique never before seen in flow measurement to deliver reliable results across Flow Pulse Unique, non-invasive clamp-on flow monitor Easily installed and simple to set up, Flow Pulse uses an acoustic technique never before seen in flow measurement to deliver reliable results across

More information

Experiment 3 Pipe Friction

Experiment 3 Pipe Friction EML 316L Experiment 3 Pipe Friction Laboratory Manual Mechanical and Materials Engineering Department College of Engineering FLORIDA INTERNATIONAL UNIVERSITY Nomenclature Symbol Description Unit A cross-sectional

More information

FLOW MEASUREMENT 2001 INTERNATIONAL CONFERENCE DERIVATION OF AN EXPANSIBILITY FACTOR FOR THE V-CONE METER

FLOW MEASUREMENT 2001 INTERNATIONAL CONFERENCE DERIVATION OF AN EXPANSIBILITY FACTOR FOR THE V-CONE METER FLOW MEASUREMENT 200 INTERNATIONAL CONFERENCE DERIVATION OF AN EXPANSIBILITY FACTOR FOR THE V-CONE METER Dr D G Stewart, NEL Dr M Reader-Harris, NEL Dr R J W Peters, McCrometer Inc INTRODUCTION The V-Cone

More information

Gas Custody Transfer Calibration

Gas Custody Transfer Calibration Gas Custody Transfer Calibration Using multi variable temperature / pressure calibrators for flowmeter calibration 2013 Introduction Gas custody transfer flow computers require special calibration to perform

More information

Training programme on flow measurements

Training programme on flow measurements WMO / OMM Autorite du Bassin du Niger Niger-HYCOS and Volta-HYCOS Projects Training programme on flow measurements 2 nd part : Flow measurement techniques Flow measurements and calculations Definitions

More information

Flow Measurement in Pipes and Ducts. Flow Measurement in Pipes and Ducts, Course #503. Presented by:

Flow Measurement in Pipes and Ducts. Flow Measurement in Pipes and Ducts, Course #503. Presented by: Flow Measurement in Pipes and Ducts, Course #503 Presented by: PDH Enterprises, LLC PO Box 942 Morrisville, NC 27560 www.pdhsite.com This course is about measurement of the flow rate of a fluid flowing

More information

ABB Flowmeters Review of industrial processing flowmeters

ABB Flowmeters Review of industrial processing flowmeters White paper ABB Flowmeters Review of industrial processing flowmeters Understanding flowmeters and their pros and cons By Ron DiGiacomo, ABB Measurement Products One of the most critical measurements in

More information

For Multi-Parameter Meters see mvx

For Multi-Parameter Meters see mvx BULLETIN BULLETIN EM20607 VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up

More information

Correcting a Coriolis Meter for Two Phase Oil & Gas Flow

Correcting a Coriolis Meter for Two Phase Oil & Gas Flow Correcting a Coriolis Meter for Two Phase Oil & Gas Flow Chris Mills, NEL 1 INTRODUCTION In the oil & gas industry, the requirement for flow measurement of two phase oil and gas flow is prevalent. This

More information

Aids needed for demonstrations: viscous fluid (water), tubes (pipes), injections, paper, stopwatches, vessels,, weights

Aids needed for demonstrations: viscous fluid (water), tubes (pipes), injections, paper, stopwatches, vessels,, weights 1 Viscous and turbulent flow Level: high school (16-17 years) hours (2 hours class teaching, 2 hours practical excercises) Content: 1. Viscous flow 2. Poiseuille s law 3. Passing from laminar to turbulent

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Basic Principles in Microfluidics

Basic Principles in Microfluidics Basic Principles in Microfluidics 1 Newton s Second Law for Fluidics Newton s 2 nd Law (F= ma) : Time rate of change of momentum of a system equal to net force acting on system!f = dp dt Sum of forces

More information

Introduction to acoustic imaging

Introduction to acoustic imaging Introduction to acoustic imaging Contents 1 Propagation of acoustic waves 3 1.1 Wave types.......................................... 3 1.2 Mathematical formulation.................................. 4 1.3

More information

Diffusion and Fluid Flow

Diffusion and Fluid Flow Diffusion and Fluid Flow What determines the diffusion coefficient? What determines fluid flow? 1. Diffusion: Diffusion refers to the transport of substance against a concentration gradient. ΔS>0 Mass

More information

INTERFERENCE OF SOUND WAVES

INTERFERENCE OF SOUND WAVES 1/2016 Sound 1/8 INTERFERENCE OF SOUND WAVES PURPOSE: To measure the wavelength, frequency, and propagation speed of ultrasonic sound waves and to observe interference phenomena with ultrasonic sound waves.

More information

The Viscosity of Fluids

The Viscosity of Fluids Experiment #11 The Viscosity of Fluids References: 1. Your first year physics textbook. 2. D. Tabor, Gases, Liquids and Solids: and Other States of Matter (Cambridge Press, 1991). 3. J.R. Van Wazer et

More information

measurement, but almost any pipe elbow can be calibrated Elbow meters are not as potentially accurate as venturi,

measurement, but almost any pipe elbow can be calibrated Elbow meters are not as potentially accurate as venturi, Lecture 14 Flow Measurement in Pipes I. Elbow Meters An elbow in a pipe can be used as a flow measuring device much in the same way as a venturi or orifice plate The head differential across the elbow

More information

Thermal Dispersion Mass Flow

Thermal Dispersion Mass Flow Thermatel Thermal Dispersion Mass Flow Measurement Handbook Table of Contents Introduction...1 What is Mass Flow Measurement?...1 Types of Flow Transmitters...4 Differential Pressure...4 Orifice...4 Venturi...6

More information

Open Channel Flow. M. Siavashi. School of Mechanical Engineering Iran University of Science and Technology

Open Channel Flow. M. Siavashi. School of Mechanical Engineering Iran University of Science and Technology M. Siavashi School of Mechanical Engineering Iran University of Science and Technology W ebpage: webpages.iust.ac.ir/msiavashi Email: msiavashi@iust.ac.ir Landline: +98 21 77240391 Fall 2013 Introduction

More information

2.0 BASIC CONCEPTS OF OPEN CHANNEL FLOW MEASUREMENT

2.0 BASIC CONCEPTS OF OPEN CHANNEL FLOW MEASUREMENT 2.0 BASIC CONCEPTS OF OPEN CHANNEL FLOW MEASUREMENT Open channel flow is defined as flow in any channel where the liquid flows with a free surface. Open channel flow is not under pressure; gravity is the

More information

Oil and Gas Custody Transfer

Oil and Gas Custody Transfer By Emerie Dupuis Daniel Measurement and Control, Emerson Process Management Oil and Gas Custody Transfer When money changes hands, flow measurement accuracy matters. When flow measurement is performed

More information

Ultrasonic Gas Meters for Industrial and Commercial Applications. Ohio Gas Association Technical Seminar March 27-28,2014

Ultrasonic Gas Meters for Industrial and Commercial Applications. Ohio Gas Association Technical Seminar March 27-28,2014 Ultrasonic Gas Meters for Industrial and Commercial Applications Ohio Gas Association Technical Seminar March 27-28,2014 Objectives Technology Operation Benefits Applications Approvals and Standards Products

More information

GLOBAL COLLEGE OF ENGINEERING &TECHNOLOGY: YSR DIST. Unit VII Fiber Optics Engineering Physics

GLOBAL COLLEGE OF ENGINEERING &TECHNOLOGY: YSR DIST. Unit VII Fiber Optics Engineering Physics Introduction Fiber optics deals with the light propagation through thin glass fibers. Fiber optics plays an important role in the field of communication to transmit voice, television and digital data signals

More information

physics 1/12/2016 Chapter 20 Lecture Chapter 20 Traveling Waves

physics 1/12/2016 Chapter 20 Lecture Chapter 20 Traveling Waves Chapter 20 Lecture physics FOR SCIENTISTS AND ENGINEERS a strategic approach THIRD EDITION randall d. knight Chapter 20 Traveling Waves Chapter Goal: To learn the basic properties of traveling waves. Slide

More information

Detection of Leak Holes in Underground Drinking Water Pipelines using Acoustic and Proximity Sensing Systems

Detection of Leak Holes in Underground Drinking Water Pipelines using Acoustic and Proximity Sensing Systems Research Journal of Engineering Sciences ISSN 2278 9472 Detection of Leak Holes in Underground Drinking Water Pipelines using Acoustic and Proximity Sensing Systems Nanda Bikram Adhikari Department of

More information

Rock Bolt Condition Monitoring Using Ultrasonic Guided Waves

Rock Bolt Condition Monitoring Using Ultrasonic Guided Waves Rock Bolt Condition Monitoring Using Ultrasonic Guided Waves Bennie Buys Department of Mechanical and Aeronautical Engineering University of Pretoria Introduction Rock Bolts and their associated problems

More information

Testing Protocol for Differential Pressure Measurement Devices API MPMS Chapter 22.2

Testing Protocol for Differential Pressure Measurement Devices API MPMS Chapter 22.2 Testing Protocol for Differential Pressure Measurement Devices API MPMS Chapter 22.2 Steve Baldwin Chevron Energy Technology Company Houston, Texas USA Casey Hodges CEESI Measurement Solutions. Nunn, Colorado

More information

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems F ox W hi t e Paper Reduce Energy Costs and Enhance Emissions Monitoring Systems A Technical White Paper from Fox Thermal Instruments Rich Cada, VP Sales & Marketing, Fox Thermal Instruments, Inc. 399

More information

A Guide to Acousto-Optic Modulators

A Guide to Acousto-Optic Modulators A Guide to Acousto-Optic Modulators D. J. McCarron December 7, 2007 1 Introduction Acousto-optic modulators (AOMs) are useful devices which allow the frequency, intensity and direction of a laser beam

More information

AP1 Waves. (A) frequency (B) wavelength (C) speed (D) intensity. Answer: (A) and (D) frequency and intensity.

AP1 Waves. (A) frequency (B) wavelength (C) speed (D) intensity. Answer: (A) and (D) frequency and intensity. 1. A fire truck is moving at a fairly high speed, with its siren emitting sound at a specific pitch. As the fire truck recedes from you which of the following characteristics of the sound wave from the

More information

Flow Sensors. - mass flow rate - volume flow rate - velocity. - stream line parabolic velocity profile - turbulent vortices. Methods of measurement

Flow Sensors. - mass flow rate - volume flow rate - velocity. - stream line parabolic velocity profile - turbulent vortices. Methods of measurement Flow Sensors Flow - mass flow rate - volume flow rate - velocity Types of flow - stream line parabolic velocity profile - turbulent vortices Methods of measurement - direct: positive displacement (batch

More information

APPENDIX A CONTROL VALVE TESTING PROCEDURES AND EQUATIONS FOR LIQUID FLOWS

APPENDIX A CONTROL VALVE TESTING PROCEDURES AND EQUATIONS FOR LIQUID FLOWS APPENDIX A CONTROL VALVE TESTING PROCEDURES AND EQUATIONS FOR LIQUID FLOWS Section A.1. Flow Coefficients Definition The flow coefficient or pressure loss coefficient is used to relate the pressure loss

More information

Steven R. McManus Environmental Product Support Teledyne Isco

Steven R. McManus Environmental Product Support Teledyne Isco Steven R. McManus Environmental Product Support Teledyne Isco Flow Measurement Applications and Technologies. Methods of flow measurement Technologies of flow measurement Flow Rate Applications Channel

More information

1) The time for one cycle of a periodic process is called the A) wavelength. B) period. C) frequency. D) amplitude.

1) The time for one cycle of a periodic process is called the A) wavelength. B) period. C) frequency. D) amplitude. practice wave test.. Name Use the text to make use of any equations you might need (e.g., to determine the velocity of waves in a given material) MULTIPLE CHOICE. Choose the one alternative that best completes

More information

Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications

Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications Janet E. Semmens Sonoscan, Inc. 2149 E. Pratt Boulevard Elk Grove Village, IL 60007 USA Phone: (847)

More information

DESIGN AND EVALUATION OF PROBE WITH THREE DEGREE- OF-FREEDOM FOR NON-DESTRUCTIVE TEST USING THREE- DIMENSIONAL FINITE ELEMENT METHOD

DESIGN AND EVALUATION OF PROBE WITH THREE DEGREE- OF-FREEDOM FOR NON-DESTRUCTIVE TEST USING THREE- DIMENSIONAL FINITE ELEMENT METHOD DESIGN AND EVALUATION OF PROBE WITH THREE DEGREE- OF-FREEDOM FOR NON-DESTRUCTIVE TEST USING THREE- DIMENSIONAL FINITE ELEMENT METHOD Masafumi Aoyanagi Graduate School of Systems and Information Engineering,

More information

APPLICATION OF DENSITOMETERS TO LIQUID MEASUREMENT Class # 2010

APPLICATION OF DENSITOMETERS TO LIQUID MEASUREMENT Class # 2010 APPLICATION OF DENSITOMETERS TO LIQUID MEASUREMENT Class # 2010 Colin B. Blakemore Sr. Product Specialist Pipeline & Gas Measurement Products AMETEK Process Instruments 455 Corporate Boulevard Newark,

More information

Advances in Thermal Dispersion Mass Flow Meter Accuracy

Advances in Thermal Dispersion Mass Flow Meter Accuracy Advances in Thermal Dispersion Mass Flow Meter Accuracy By Dan McQueen President Fluid Components International (FCI) Advances in Thermal Dispersion Mass Flow Meter Accuracy By Dan McQueen President Fluid

More information

FXA 2008. UNIT G485 Module 4 5.4.3 Ultrasound. Candidates should be able to :

FXA 2008. UNIT G485 Module 4 5.4.3 Ultrasound. Candidates should be able to : 1 Candidates should be able to : ULTRASOUND Describe the properties of ultrasound. ULTRASOUND is any sound wave having a frequency greater than the upper frequency limit of human hearing (20 khz). Describe

More information

Rosemount Orifice Plate in Wet Gas

Rosemount Orifice Plate in Wet Gas 00870-0100-4810 January 2006 Page 1 Rosemount Orifice Plate in Wet Gas This paper discusses the phenomenon of wet gas measurement, definitions, and the need to accurately measure this mixture. This paper

More information

NUMERICAL ANALYSIS OF THE EFFECTS OF WIND ON BUILDING STRUCTURES

NUMERICAL ANALYSIS OF THE EFFECTS OF WIND ON BUILDING STRUCTURES Vol. XX 2012 No. 4 28 34 J. ŠIMIČEK O. HUBOVÁ NUMERICAL ANALYSIS OF THE EFFECTS OF WIND ON BUILDING STRUCTURES Jozef ŠIMIČEK email: jozef.simicek@stuba.sk Research field: Statics and Dynamics Fluids mechanics

More information

Waves - Transverse and Longitudinal Waves

Waves - Transverse and Longitudinal Waves Waves - Transverse and Longitudinal Waves wave may be defined as a periodic disturbance in a medium that carries energy from one point to another. ll waves require a source and a medium of propagation.

More information

Solid shape molding is not desired in injection molding due to following reasons.

Solid shape molding is not desired in injection molding due to following reasons. PLASTICS PART DESIGN and MOULDABILITY Injection molding is popular manufacturing method because of its high-speed production capability. Performance of plastics part is limited by its properties which

More information

Series DFMT Digital Paddlewheel Flowmeter

Series DFMT Digital Paddlewheel Flowmeter Series DFMT Digital Paddlewheel Flowmeter Bulletin F-DFMT Specifications - Installation Operating Instructions -/8 [00] -/ [8] -/8 [00] A The Series DFMT Digital Paddlewheel Flow Transmitter provides instantaneous

More information

Understanding the Flo-Dar Flow Measuring System

Understanding the Flo-Dar Flow Measuring System Understanding the Flo-Dar Flow Measuring System Independent tests verify non-contact flowmeter is highly accurate under both open channel and surcharge conditions TM Flo-Dar is the only non-contact open

More information

Sensors and Cellphones

Sensors and Cellphones Sensors and Cellphones What is a sensor? A converter that measures a physical quantity and converts it into a signal which can be read by an observer or by an instrument What are some sensors we use every

More information

TISSUE MIMICKING GEL QUALITY LE PHANTOM SERIES DESIGN. performance the ultrasound labs ofand. icking material has the same attenuation mim-

TISSUE MIMICKING GEL QUALITY LE PHANTOM SERIES DESIGN. performance the ultrasound labs ofand. icking material has the same attenuation mim- QUALITY Tissue Benefits Mimicking of s RMI recognized RMI as the ultrasound standard phantoms for quality are performance the ultrasound labs ofand hospitals, manufacturers. clinics Sophisticated and ultrasound

More information

Entrained Gas Diagnostic with Intelligent Differential Pressure Transmitter

Entrained Gas Diagnostic with Intelligent Differential Pressure Transmitter January Page Entrained Gas Diagnostic with Intelligent Differential Pressure Transmitter Dave Wehrs - Director, Pressure Engineering Andrew Klosinski - Application Engineer, Pressure Diagnostics Emerson

More information

Tadahiro Yasuda. Introduction. Overview of Criterion D200. Feature Article

Tadahiro Yasuda. Introduction. Overview of Criterion D200. Feature Article F e a t u r e A r t i c l e Feature Article Development of a High Accuracy, Fast Response Mass Flow Module Utilizing Pressure Measurement with a Laminar Flow Element (Resistive Element) Criterion D200

More information

Viscous flow in pipe

Viscous flow in pipe Viscous flow in pipe Henryk Kudela Contents 1 Laminar or turbulent flow 1 2 Balance of Momentum - Navier-Stokes Equation 2 3 Laminar flow in pipe 2 3.1 Friction factor for laminar flow...........................

More information

XI / PHYSICS FLUIDS IN MOTION 11/PA

XI / PHYSICS FLUIDS IN MOTION 11/PA Viscosity It is the property of a liquid due to which it flows in the form of layers and each layer opposes the motion of its adjacent layer. Cause of viscosity Consider two neighboring liquid layers A

More information

Accurate Air Flow Measurement in Electronics Cooling

Accurate Air Flow Measurement in Electronics Cooling Accurate Air Flow Measurement in Electronics Cooling Joachim Preiss, Raouf Ismail Cambridge AccuSense, Inc. E-mail: info@degreec.com Air is the most commonly used medium to remove heat from electronics

More information

Shielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness

Shielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness Shielding Effectiveness Test Method Harbour s LL, SB, and SS Coaxial Cables Designs for Improved Shielding Effectiveness Harbour Industries 4744 Shelburne Road Shelburne Vermont 05482 USA 802-985-3311

More information

Noise associated with the ground water systems serving residential geothermal heat pumps

Noise associated with the ground water systems serving residential geothermal heat pumps Noise associated with the ground water systems serving residential geothermal heat pumps Jeffrey L. FULLERTON 1 Acentech Incorporated, United States ABSTRACT Geothermal heat pumps are an energy efficient

More information

INSTALLATION, OPERATION & MAINTENANCE MANUAL

INSTALLATION, OPERATION & MAINTENANCE MANUAL INSTALLATION, OPERATION & MAINTENANCE MANUAL Flanged Disk Check Valve with Strainer Ref. GENEBRE: 2450 2451 2452 1 INSTRUCTIONS FOR INSTALLATION, OPERATION & MAINTENANCE MANUAL 1. Spare parts... 3 1.1

More information

Waves Sound and Light

Waves Sound and Light Waves Sound and Light r2 c:\files\courses\1710\spr12\wavetrans.doc Ron Robertson The Nature of Waves Waves are a type of energy transmission that results from a periodic disturbance (vibration). They are

More information

APPLICATION NOTE AP050830

APPLICATION NOTE AP050830 APPLICATION NOTE AP050830 Selection and use of Ultrasonic Ceramic Transducers Pro-Wave Electronics Corp. E-mail: sales@pro-wave.com.tw URL: http://www.prowave.com.tw The purpose of this application note

More information

v = λ f this is the Golden Rule for waves transverse & longitudinal waves Harmonic waves The golden rule for waves Example: wave on a string Review

v = λ f this is the Golden Rule for waves transverse & longitudinal waves Harmonic waves The golden rule for waves Example: wave on a string Review L 23 Vibrations and Waves [3] resonance clocks pendulum springs harmonic motion mechanical waves sound waves golden rule for waves musical instruments The Doppler effect Doppler radar radar guns Review

More information

Acousto-optic modulator

Acousto-optic modulator 1 of 3 Acousto-optic modulator F An acousto-optic modulator (AOM), also called a Bragg cell, uses the acousto-optic effect to diffract and shift the frequency of light using sound waves (usually at radio-frequency).

More information