INSTRUCTION MANUAL. Installing the Software NO. XX NOTES Refer to XX134 REV. 510 SEC. 3

Size: px
Start display at page:

Download "INSTRUCTION MANUAL. Installing the Software NO. XX134-24-00. NOTES Refer to XX134 REV. 510 SEC. 3"

Transcription

1 INSTRUCTION MANUAL NOTES Refer to XX134 NO. XX REV. 510 Vicon Direct Control Software It is possible to control the SurveyorVFT or Surveyor -Mini camera dome from a PC using the Direct Control software. Surveyor Direct Control software can be installed on a PC type computer and used to operate any Surveyor Camera Dome on the RS-422 bus. The software works with all versions of SurveyorVFT, Surveyor-Mini and older versions of Surveyor Camera Domes. Note: The Direct Control Software does not work with the IP models of the SurveyorVFT or Surveyor-Mini. Typical application: To test a new installation or troubleshoot an existing installation, simply select the dome (Receiver#), connect, and test PTZ (Pan, Tilt, and Zoom) functions, Aux. functions, etc. The RS-422 bus as well as the functionality of all domes on the bus can be verified. Note: It is recommended to remove any older versions of Vicon s Direct Control program before installing this software. Before the software for the dome can be upgraded, it is necessary to setup the hardware. The PC must be connected to the dome by means of Vicon s V422-CONV RS-232/RS-422 Interface converter/adapter and a cable assembly. Note: If using an SVFT-PRS-RS232 version, the RS-232 adapter is built-in and the external converter is not required. There are two system configurations, a standalone system, with one dome and one PC, and a star configuration, using a V1400X-IDL. See Figures 1 and 2. Installing the Software The software should be installed on the computer prior to connecting the camera dome to a computer with the following minimum configuration: Pentium 233 MHz with 32 MB RAM 2 MB of free hard drive space CD-ROM drive 1 free serial port (COM 1, COM 2, COM 3 or COM 4) Mouse (for navigation) Windows '95, '98 (second edition), ME, NT, 2000 Professional or XP Home or Professional RS-232 to RS-422 protocol converter/adapter Software can be downloaded from Vicon s FTP site: ftp://ftp.vicon-cctv.com/software/03_camera/. 1. Power on and boot the computer to the Windows desktop. 2. Place the CD into the drive. 3. If it does not autorun, run the file on the CD named setup.exe. 4. Follow the software prompts to install the software onto the hard drive in the desired directory. Setting Up the Connection: Power down all equipment and use Figure 1 or 2 (standalone or star configuration) to make all connections between the camera dome and the host computer. Copyright 2009 Vicon Industries Inc. All rights reserved. Product specifications subject to change without notice. Vicon and its logo, Surveyor and SUrveyorVFT are registered trademarks of Vicon Industries Inc. Windows is a registered trademark of Microsoft Corp. Pentium is a registered trademark of Intel Corp. Vicon part number Section 3 Rev 510 VICON INDUSTRIES INC., 89 ARKAY DRIVE, HAUPPAUGE, NEW YORK TEL: CCTV (2288) FAX: CCTV (2288) TOLL FREE: Hour Technical Support: VICON ( ) UK: +44 (0) WEB: SEC. 3

2 Figure 1 Standalone Configuration (Duplex shown, may be simplex or duplex; SurveyorVFT shown) Pin Out Connections RS-232/RS-422 Converter SurveyorVFT COMM TB3 Signal To Signal RXD- (RESPONSE IN -) PIN 4 (RESPONSE OUT -) RXD+ (RESPONSE IN +) PIN 3 (RESPONSE OUT +) GND (GROUND) PIN 5 (GROUND) T/R+ (COMMAND OUT +) PIN 1 (COMMAND IN +) T/R- (COMMAND OUT -) PIN 2 (COMMAND IN -) RS-232/RS-422 Converter Surveyor-Mini COMM TB3 Signal To Signal RXD- (RESPONSE IN -) PIN 3 (RESPONSE OUT -) RXD+ (RESPONSE IN +) PIN 4 (RESPONSE OUT +) GND (GROUND) PIN 5 (GROUND) T/R+ (COMMAND OUT +) PIN 1 (COMMAND IN +) T/R- (COMMAND OUT -) PIN 2 (COMMAND IN -) 2

3 Figure 2 Star Configuration (SurveyorVFT illustrated) Tech Tips 1.) Power down all components before wiring. 2.) Verify that the address DIP Switch is set to "address 1". 3.) Verity that the configuration DIP Switch is set correctly (SurveyorVFT: RS422, Duplex, VPS, NTSC or PAL selected per appropriate system; Surveyor-Mini: Duplex, VPS - RS-422 and NTSC/PAL are auto-sensed). 4.) When using shielded twisted-pair cable, the shield is used as the ground (G) wire. 5.) Plug the adapter into the computer serial port (COM 1 or COM 2) before the computer has been powered on. 3

4 Preparation for Setup 1. With the software installed and the dome properly connected to the computer, power on the computer. 2. Upon boot completion, run the Surveyor Direct Control software. The following screen will appear: Note: There is a choice of protocols, Vicon, Cohu or NTCIP, and this will effect the program options. NTCIP is not available for the Surveyor-Mini. Vicon Mode Note: In Vicon mode, Auto Pan and Auto Iris are framed to indicate that they have additional functions when the dome is in Program mode. 4

5 Cohu Mode Note: When using the Cohu protocol, Auto Pan, Receiver Alarm and Aux 1-6 are disabled and grayed out, since there is no Cohu equivalent of these functions. Also, presets only go up to PRESET 64, which is used to enter Program mode. Focus Far and Iris Close are framed to indicate that they have additional functions when dome is in Program mode (Auto Pan and Auto Iris, respectively). 5

6 NTCIP Mode Note: When using the NTCIP protocol Aux 1-6, Lens Speed and Receiver Alarm are disabled and grayed out, since there is no NTCIP equivalent of these functions. Auto Pan and Auto Iris are framed to indicate that they have additional functions when dome is in Program mode. Not available for Surveyor-Mini. 3. Verify that the Receiver # is set to assigned dome address. Note: The Receiver # selected MUST match the DIP settings of the dome being tested. 4. Verify that the Comm Port: is set to the appropriate port (COM 1, COM 2 and on some computers COM 3 or COM 4). This is the Comm Port the RS-422 adapter is connected to. 6

7 5. Verify that the Baud Rate is set to 4800,N,8,1. Note: The Baud rate MUST match the settings of the dome being tested. 6. Power on the camera dome and the following series of screens (SurveyorVFT shown in examples) should display on the Analog Monitor: 7. With the black screen displayed, select the Connect button with the mouse on the Surveyor Direct Control Main Screen on the computer monitor. 8. The dome should immediately connect to the computer and the following screen display. 9. If this screen is not immediately displayed, the baud rate might have been different in the dome. To connect, select the red button in the center of the joystick with the mouse and move it. The black screen on the Analog Monitor will briefly display a blinking cursor to the right of the word "Duplex" (if connected in duplex mode) and a message as follows: 10. Continue to move the joystick until the Vicon Surveyor screen (above) is displayed. The connection is complete. 7

8 Using the Vicon Surveyor Direct Control Program With the camera dome and computer communicating, the dome can now be operated using the panel controls in the software. The following is a description of all controls: Comm Settings: This section allows you to select the Receiver to control, select the PC s RS-232 Communication Port and the Baud Rate to communicate with the camera dome. a) Receiver If the installation has a number of cameras connected on an RS-422 loop, enter the number of the specific camera that is to be tested. If a number of cameras are to be tested, simply change the number and press the Connect button to send commands to the new selection. b) Comm Port This refers to the RS-232 Serial Port, usually found on the back of the PC. For most PCs and Laptops, use Comm Port 1. c) Baud Rate By default, 4800 baud is fine. However, if testing is required at a higher baud rate, select 9600 or baud. After changing the Baud Rate, press the Connect button to apply the new setting. Connect: This button initiates the communication between the Direct Control program and the selected receiver. When the Connect button is pressed, it checks the PC Comm Port; if it s valid and unused, it will open a simplex or duplex connection between the PC and the selected receiver. The progress bar shows the connection activity. 8

9 Pan and Tilt: By selecting the red button of the simulated joystick and moving it within the black box, the camera can be adjusted up, down, left and right in the same orientation as the displayed screen. Preset Mode: Presets allow setup of, and access to, the camera dome features. To program certain features or preset positions, the Program Mode option must be selected. To recall these features or preset positions, the Run Mode option must be selected. Preset functions can represent a variety of features. To access a preset, perform the following routine: 1. Select the Program or Run Mode option. 2. Select the Preset # right arrow and click on one of the 99 preset values. It will display in the box. 3. Select the PP Enter button. The preset has been programmed or solved. PRESET FUNCTION NUMBER 1 to 79 Preset positions 80 to 87 Tour sequences 88 to 89 Autotour sequences 90 Pan/Tilt lockout 93 Set response line polarity 94 Enter Dome menu system 95 Auto-Baud Detect feature 96 Program Dome sectors 97 Initiate Dome reset 98 Autopan limits 99 Set manual pan limits The table on the left shows preset numbers and their functions, which are described in detail below. There are no commands associated with certain presets. These have been reserved for future use or advanced programming and diagnostic tools. These presets pertain to Vicon mode only. Note: Surveyor-Mini allows programming preset numbers Preset 1-79 (Preset Positions) When a preset number is stored, the current position of the camera is written into that preset memory location. When the number is recalled, the camera moves to the stored position. This is called solving a preset. Presets are usually solved at the maximum speed, typically less than 1 second; if a preset is assigned to a tour or salvo, the preset recall speed is programmable. Camera focus is also stored as part of the preset; if the image is out of focus when the preset is stored, it will be out of focus when the preset is solved, even if autofocus is enabled. When a preset is recalled, the corresponding preset title is displayed on the screen (when preset titles have been enabled). If the operator attempts to recall a preset number that has not been stored, the message Preset Not Stored appears on the screen for a short period and the camera position does not change. Pressing any command key or moving the joystick will also remove the message. Preset (Tour Sequences) A tour is a series of up to 32 events or actions. Accessing the Program Tour option will bring up an on-screen menu that allows programming of each tour event. This is described in greater detail in the Preset/Tour Handling menu section. Recalling a tour initiates the sequence of events that corresponds to that tour number. A longer sequence of actions can be prepared by chaining 2 or more tours together. Preset (Autotour Sequences) An Autotour is a series of up to 256 pan, tilt and zoom actions. Accessing the Program Autotour option will bring up an on-screen menu which allows dynamic programming of each autotour event. This is described in greater detail in the Preset/Tour Handling menu section. Preset 90 (Pan/Tilt Lockout) Storing preset 90 will disable joystick control of that dome, and the message Pan/Tilt Disabled will momentarily appear on the screen. Any time the joystick is moved, the message will reappear. To restore pan/tilt operation, preset 90 must be stored again. This feature prevents the camera dome s position from being tampered with. This allows the dome to respond only to preset positions, eliminating the operator s ability to manually position the dome. It also allows a unit to be temporarily locked onto a subject for recording or monitoring specific activity. Recalling preset 90 has no effect. The camera dome retains its capability of zoom, focus and iris control while locked. Preset 93 (Set Response Line Polarity) (Duplex Only) The camera dome checks for polarity of the command in lines through the auto baud detect feature. The baud detect cycles through 4800+/4800-/9600+/9600- /19200+/19200-, indicating not only the baud rate it is searching for but also the polarity that the receive lines are set to. When preset 93 is selected, the dome will periodically cycle the polarity of the COMM IN+ and COMM IN- 9

10 lines. During the cycling, pan the joystick and press either the A/I or A/P key. As soon as one of the respective lights illuminates, press the AUX2 key. This locks in the correct polarity for operation. Preset 94 (Enter Dome Menu System) Many camera dome features are accessed through a series of onscreen menus. These are described in the following programming menu sections and accessed by storing preset 94 (in Vicon mode). A Menu Flow Chart is included at the back of this manual. Recalling preset 94 has no effect. For convenience, when performing programming, pressing the L-SPD (lens speed) button will display a black background. Preset 95 (Auto-Baud Detect Feature) Auto-baud detect functions after installing defaults, using preset 95, when switching Vicoax to NOVA (VPS) and upon power-up when the dome sees an incorrect baud rate from keypad or control system. It allows the camera dome to detect a new baud rate from the host controller without having to fully reboot the camera dome and lose all stored configuration parameters. Be sure that auto home on power up is disabled before executing this command. Symbols are used to display the status of the detection process. The * symbol indicates that valid data at the correct baud rate has been received, the X symbol represents a framing error has been received and the - symbol indicates that no data has been received. Recalling preset 95 has no effect. Preset 96 (Program Dome Sectors) The camera dome has the ability to divide its 360 field-of-view into sections or sectors. There may be up to 16 sectors and the boundaries for each are programmed for each individual dome. An individual title may be programmed for each sector and video may be enabled or disabled. More information on disabling sector video or sector censoring and titling may be found in the Camera Controller and Source Titling menu sections. Storing preset 96 will begin the sector programming process by establishing the left boundary for sector 1. Pan the camera to the right and press the AP (autopan) key to set the right boundary for sector 1, which is also the left boundary of sector 2. Continue panning the camera and pressing AP until all 16 boundaries have been programmed. If fewer than 16 sectors are required, press AP repeatedly at the right boundary of the last sector you will be programming to use up all the boundary numbers and exit sector-programming mode. When the camera is moved, the corresponding sector title is displayed on the screen (when sector titles have been enabled). If the video is disabled for a given sector, a black screen with the words sector censored will appear when the camera enters that sector and video will be restored when the camera moves to a sector where video is enabled. Sector programming can be aborted by issuing a preset recall; this will also erase any prior sector programming. Recalling preset 96 has no effect. Preset 97 (Initiate Dome Reset) Storing preset 97 resets all of the system software and performs the poweron self-test. This is called a soft reset because no memory settings are affected. All user programmed options such as titles and presets remain unchanged. Recalling preset 97 has no effect. Preset 98 (Programming Autopan Limits) When a camera dome is selected on a keyboard, pressing the AP (autopan) key will start the camera in motion, panning at a predetermined speed. To change the speed Press and hold the AP key while moving the joystick to the desired speed. When the speed is correct, release the AP button and then the joystick. Each dome may have its own autopan speed and pressing the autopan key will start the dome panning at the last speed selected for that dome. (When using a Kollector DVR, shut off AP, move the slider to desired speed and press AP again.) In continuous rotation only, the autopan command will cause the dome to reverse direction. To stop autopanning Any other pan command will disable autopan. This includes pressing the AP key again, panning the camera with the joystick, or recalling a preset. To set the autopan limits When a continuous rotation dome is in autopan, it will rotate in a full circle until autopan is disabled. When an application, such as a wall-mounted camera on a building, does not require continuous rotation, limits are set to define the left and right boundaries. Storing preset 98 will bring up a series of prompts to set the left and right autopan limits with the AUX 2 and AUX 3 keys. When the autopan limits are set and the camera is placed into autopan it will pan until it reaches a limit. It will then reverse direction until it reaches the opposite limit, repeating this cycle indefinitely. To clear the autopan limits Store preset 98. Press AUX 2 and AUX 3 without panning to set the autopan limits to the same position. By recording both limits on the same point they will both be deleted. The dome will now rotate continuously when placed in autopan mode until new limits are programmed. Recalling presets 98 has no effect. 10

11 Preset 99 (Set Manual Pan Limits) Storing preset 99 will bring up a series of prompts to set the left and right manual pan limits with the AUX 2 and AUX 3 keys. After these are set, the physical range between these limits is the valid range. The camera dome will not move outside these limits. Setting pan limits also sets AP limits if the AP limits are outside the of the pan limits. The only exceptions are prerecorded tours and previously stored presets. To clear the pan limits, press AUX 2 and AUX 3 without panning. Send Commands: This list of commands provides instant control of zoom, focus, iris, auto pan, auxiliary functions and lens speed. When the text for a particular function is selected with the mouse, the function is performed and the indicator to the right will blink. They operate as follows: Zoom Out When selected, the camera lens will display a closer image of the current scene. Zoom In When selected, the camera lens will display a farther image of the current scene. Focus Near When selected, the camera lens will attempt to display closer objects clear. Focus Far When selected, the camera lens will attempt to display farther objects clear. Iris Open When selected, the camera lens will display a brighter image. Iris Close When selected, the camera lens will display a darker image. Aux (1-6) When selected, a pre-established external function will be triggered momentarily or indefinitely. Lens Speed When selected, the camera lens speed toggles from Low, Medium and High. Indication is displayed on the Analog Monitor when titles are enabled. 11

12 Absolute Positioning Information (Cohu mode only:) Next to the Pan and Tilt label the labels P (for Pan) T (for Tilt) and Z (for Zoom) show absolute positioning information from the dome. Note: There needs to be a duplex connection between the PC and the dome to receive this information. Troubleshooting: RS-232 to RS-422 Protocol Converter - It is very important that the RS-232 to RS-422 adapter be wired correctly. The RS-232 side MUST be connected to the PC and the RS-422 side goes to the camera dome. This does not pertain to the SVFT-PRS-RS232 version. Serial (COM) Port If you suspect that the computer serial port is not working correctly, run a software diagnostic or connect another device (such as a modem) to see if it is indeed operational. If it continues to fail, try using an alternate serial port. Camera Dome When the camera dome is powered on, it must display the series of boot screens previously displayed. If not, there is a serious problem; contact Vicon Tech Support for assistance. If the dome boots normally and does not connect, verify that the wiring from the terminal block or box is correct. Wiring is the most common cause of failed camera dome communication. Computer If the computer is not running the program properly, consult the computer manufacturer for assistance. 12

13 Vicon Industries Inc. Corporate Headquarters 89 Arkay Drive Hauppauge, New York CCTV (2288) Fax: CCTV (2288) Vicon Europe Headquarters Brunel Way Fareham, PO15 5TX United Kingdom +44 (0) Fax: +44 (0) Germany vin-videotronic infosystems gmbh Lahnstrasse 1 D Neumuenster Phone: +49 (0) Fax: +49 (0) Vicon China Unit 5, 17/F, Metropole Square 2 On Yiu Street, Shatin New Territories, Hong Kong (852) Fax: (852) Internet Address:

Vicon Flash Upgrade Software

Vicon Flash Upgrade Software NOTES NO. REV. SEC. INSTRUCTION MANUAL Refer to XX134-11-00 1108 3 XX134 Vicon Flash Upgrade Software It is possible to upgrade software for the SurveyorVFT through a PC using the Flash Upgrade software.

More information

Vicon Flash Upgrade Software

Vicon Flash Upgrade Software INSTRUCTION MANUAL Notes Refer to XX134 NO. XX134-13-01 REV. 1212 Vicon Flash Upgrade Software It is possible to upgrade software for the SurveyorVFT and Surveyor -Mini Camera Domes through a PC using

More information

HYBRID NETWORK VIDEO RECODERS WITH INTERNAL RAID RECOVERY PROCEDURE

HYBRID NETWORK VIDEO RECODERS WITH INTERNAL RAID RECOVERY PROCEDURE XX112-91-00 HYBRID NETWORK VIDEO RECODERS WITH INTERNAL RAID RECOVERY PROCEDURE Copyright 2006 Vicon Industries Inc. All rights reserved. Product specifications subject to change without notice. Vicon

More information

IP Matrix MVC-FIPM. Installation and Operating Manual

IP Matrix MVC-FIPM. Installation and Operating Manual IP Matrix MVC-FIPM en Installation and Operating Manual IP Matrix IP Matrix Table of Contents en 3 Table of Contents 1 Preface 5 1.1 About this Manual 5 1.2 Conventions in this Manual 5 1.3 Intended Use

More information

Classroom Setup... 2 PC... 2 Document Camera... 3 DVD... 4 Auxiliary... 5. Lecture Capture Setup... 6 Pause and Resume... 6 Considerations...

Classroom Setup... 2 PC... 2 Document Camera... 3 DVD... 4 Auxiliary... 5. Lecture Capture Setup... 6 Pause and Resume... 6 Considerations... Classroom Setup... 2 PC... 2 Document Camera... 3 DVD... 4 Auxiliary... 5 Lecture Capture Setup... 6 Pause and Resume... 6 Considerations... 6 Video Conferencing Setup... 7 Camera Control... 8 Preview

More information

GV-Keyboard. User's Manual V2.0

GV-Keyboard. User's Manual V2.0 GV-Keyboard User's Manual V2.0 Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2007 GeoVision, Inc. All rights reserved.

More information

CMS-DH CENTRAL MANAGEMENT SOFTWARE

CMS-DH CENTRAL MANAGEMENT SOFTWARE CMS-DH CENTRAL MANAGEMENT SOFTWARE CMS-DH is a central management software that allows you to view and manage up to 300 DH200 series DVRs. System Requirements Your system must meet the system requirements

More information

DUKANE Intelligent Assembly Solutions

DUKANE Intelligent Assembly Solutions PC Configuration Requirements: Configuration Requirements for ipc Operation The hardware and operating system of the PC must comply with a list of minimum requirements for proper operation with the ipc

More information

User Manual V1.0. Remote Software

User Manual V1.0. Remote Software User Manual V1.0 Notice: The information in this manual was current when published. The manufacturer reserves the right to revise and improve its products. All specifications are therefore subject to change

More information

LOVELINK III- Process Monitoring, Logging, Graphing, & Configuration

LOVELINK III- Process Monitoring, Logging, Graphing, & Configuration LOVELINK III- Process Monitoring, Logging, Graphing, & Configuration VERSION 1.00.00 USER MANUAL Updated 09/13/2002 Table of Contents Hardware/Software Requirements...2 Computer Requirements...2 Instrument

More information

Universal Camera Setup Software MIC Camset. User Manual

Universal Camera Setup Software MIC Camset. User Manual Universal Camera Setup Software MIC Camset en User Manual Universal Camera Setup Software Table of Contents en 3 Table of Contents 1 Introduction 5 2 Using Quick Start Guides 6 2.1 Connecting MIC to Universal

More information

ivms-4500(android) Mobile Client Software User Manual (V1.0)

ivms-4500(android) Mobile Client Software User Manual (V1.0) ivms-4500(android) Mobile Client Software User Manual (V1.0) Thank you for purchasing our product. This manual applies to ivms-4500 (Android) mobile client software, please read it carefully for the better

More information

Manual Client Management Software HDR50-CMS

Manual Client Management Software HDR50-CMS Manual Client Management Software HDR50-CMS HDR50-CMS (Client Management Software) A-1. Install HDR50-CMS for Windows PC HDR50-CMS is a program for communication between DVR and PC to control signal and

More information

KTD-313 Data Converter. Installation Manual

KTD-313 Data Converter. Installation Manual KTD-313 Data Converter Installation Manual Copyright Disclaimer Trademarks and patents Intended use FCC compliance Copyright 2006, GE Security Inc. All rights reserved. This document may not be copied

More information

DVR-4TL/8TL/16TL Setup Guide

DVR-4TL/8TL/16TL Setup Guide Package Content DVR-4TL/8TL/16TL Setup Guide Inspect the DVR s packaging. Make sure that the DVR-4TL/8TL/16TL is packed properly. Remove all items from the box and make sure it contains the following items.

More information

Model 288B Charge Plate Graphing Software Operators Guide

Model 288B Charge Plate Graphing Software Operators Guide Monroe Electronics, Inc. Model 288B Charge Plate Graphing Software Operators Guide P/N 0340175 288BGraph (80207) Software V2.01 100 Housel Ave PO Box 535 Lyndonville NY 14098 1-800-821-6001 585-765-2254

More information

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher OPERATION MANUAL MV-410RGB Layout Editor Version 2.1- higher Table of Contents 1. Setup... 1 1-1. Overview... 1 1-2. System Requirements... 1 1-3. Operation Flow... 1 1-4. Installing MV-410RGB Layout

More information

Avigilon Control Center Web Client User Guide

Avigilon Control Center Web Client User Guide Avigilon Control Center Web Client User Guide Version: 4.12 Enterprise OLH-WEBCLIENT-E-E-Rev2 Copyright 2013 Avigilon. All rights reserved. The information presented is subject to change without notice.

More information

PORTABLE DATA COLLECTION TERMINAL

PORTABLE DATA COLLECTION TERMINAL PORTABLE DATA COLLECTION TERMINAL WINDOWS TRANSFER UTILITY HELP FILES BETA EDITION Compsee, Inc. A Subsidiary of McRae Industries, Inc. 2 Welcome Thank you for using the Apex III Windows Transfer Utility

More information

ImagineWorldClient Client Management Software. User s Manual. (Revision-2)

ImagineWorldClient Client Management Software. User s Manual. (Revision-2) ImagineWorldClient Client Management Software User s Manual (Revision-2) (888) 379-2666 US Toll Free (905) 336-9665 Phone (905) 336-9662 Fax www.videotransmitters.com 1 Contents 1. CMS SOFTWARE FEATURES...4

More information

CX Series. Video Recording Server. Quick Start Guide CX784 / CX788 / CX7816. Version 1.05.00

CX Series. Video Recording Server. Quick Start Guide CX784 / CX788 / CX7816. Version 1.05.00 CX Series Video Recording Server CX784 / CX788 / CX7816 Quick Start Guide Version 1.05.00 Contents 1.Introduction...1 1.1.Packages Contents...1 1.2.Hardware Features...2 1.3.Functional Features...4 1.4.Hard

More information

File Management Utility. T u t o r i a l

File Management Utility. T u t o r i a l File Management Utility T u t o r i a l Contents System Requirements... 2 Preparing Files for Transfer to GlobalMark... 2 Application Launch... 2 Printer Setup... 2 Communication Status... 4 Communication

More information

POWER NETWORK. 800-02577-iPcams 2/10 Rev. A

POWER NETWORK. 800-02577-iPcams 2/10 Rev. A POWER NETWORK Total Connect Online Help Guide for: ip Cameras ipcam-wi Camera ipcam-pt Pan and Tilt Camera 800-02577-iPcams 2/10 Rev. A POWER NETWORK ip Cameras Online Help Guide This guide covers the

More information

LOREX CLIENT Remote Software 4.0

LOREX CLIENT Remote Software 4.0 LOREX CLIENT Remote Software 4.0 Instruction Manual English Version 2.0 MODEL: L20WD800 Series www.lorexcctv.com Copyright 2008 LOREX Technology Inc. Table of Contents Table of Contents Software Installation...

More information

Addendum DVR670 Installation and Operation manual AM18-Q0617

Addendum DVR670 Installation and Operation manual AM18-Q0617 Security Systems Addendum DVR670 Installation and Operation manual AM18-Q0617 Security Warning The remote system access feature, designed to allow users to view their video via a PC or phone, may compromise

More information

WA-E. Integrated Client/Server Remote Control and Alarm Monitor Software for E-Series In-Picture Audio Meter/Alarm Systems

WA-E. Integrated Client/Server Remote Control and Alarm Monitor Software for E-Series In-Picture Audio Meter/Alarm Systems WA-E Integrated Client/Server Remote Control and Alarm Monitor Software for E-Series In-Picture Audio Meter/Alarm Systems User s Guide Version 1.0 06/05/03 Chromatec E-Series Alarm Monitor Software Michael

More information

Central Management Software CV3-M1024

Central Management Software CV3-M1024 Table of Contents Chapter 1. User Interface Overview...5 Chapter 2. Installation...6 2.1 Beginning Installation...6 2.2 Starting the CMS software...10 2.3 Starting it from the Start menu...10 2.4 Starting

More information

JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP

JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP AZI P/N 700-0042-B Last update May 2009 USER MANUAL JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP May 2009 ARIZONA INSTRUMENT LLC 3375 N Delaware Street Chandler,

More information

AXIS Installation Monitor. User s Manual

AXIS Installation Monitor. User s Manual AXIS Installation Monitor User s Manual Overview Setup Single camera setup One or more cameras in a network setup Device menu Monitor window Monitor menu Tips and tricks Overview AXIS Installation Monitor

More information

Getting Started with Vision 6

Getting Started with Vision 6 Getting Started with Vision 6 Version 6.9 Notice Copyright 1981-2009 Netop Business Solutions A/S. All Rights Reserved. Portions used under license from third parties. Please send any comments to: Netop

More information

APPLICATION NOTE. The DMP Software Family DMP COMPUTER SOFTWARE PROGRAMS

APPLICATION NOTE. The DMP Software Family DMP COMPUTER SOFTWARE PROGRAMS APPLICATION NOTE Contents The DMP Software Family... 1 Stand-Alone Link Software... 1 Add-on Modules for Link Software... 1 System Link End-User Panel Management Software... 2 Simple Registration and Activation...

More information

AXIS Camera Station Quick Installation Guide

AXIS Camera Station Quick Installation Guide AXIS Camera Station Quick Installation Guide Copyright Axis Communications AB April 2005 Rev. 3.5 Part Number 23997 1 Table of Contents Regulatory Information.................................. 3 AXIS Camera

More information

History of Revisions. Ordering Information

History of Revisions. Ordering Information No part of this document may be reproduced in any form or by any means without the express written consent of II Morrow Inc. II Morrow, Apollo, and Precedus are trademarks of II Morrow Inc. Windows is

More information

TR-3 Channel Editor. Software Manual

TR-3 Channel Editor. Software Manual TR-3 Channel Editor Software Manual Trilithic Company Profile Trilithic is a privately held manufacturer founded in 1986 as an engineering and assembly company that built and designed customer-directed

More information

PenMount Touch Screen Controller Board Installation Guide

PenMount Touch Screen Controller Board Installation Guide PenMount Touch Screen Controller Board Installation Guide Salt International Corp. i Preface Disclaimer The information in this document is subject to change without notice. The manufacturer makes no representations

More information

Instruction Manual. V1300X-DVC & V1300X-RVC Intelligent Remote Control Panels

Instruction Manual. V1300X-DVC & V1300X-RVC Intelligent Remote Control Panels V1300X-DVC & V1300X-RVC Intelligent Remote Control Panels Instruction Manual Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet your requirements or that the

More information

Config software for D2 systems USER S MANUAL

Config software for D2 systems USER S MANUAL DT-CONFIG SOFTWARE Config software for D2 systems USER S MANUAL CONTENTS 1. Introductions ------------------------------------------------------------------- 3 2. System Requirement and Connection ----------------------------------------

More information

Newton Backup Utility User s Guide. for the Windows Operating System

Newton Backup Utility User s Guide. for the Windows Operating System Newton Backup Utility User s Guide for the Windows Operating System K Apple Computer, Inc. 1995 Apple Computer, Inc. All rights reserved. Under the copyright laws, this manual may not be copied, in whole

More information

DIGICLIENT 8.0 Remote Agent Software

DIGICLIENT 8.0 Remote Agent Software DIGICLIENT 8.0 Remote Agent Software MODEL: D17800 Series Instruction Manual English Version 1.0 Copyright 2007 Digimerge Technologies Inc Table of Contents Table of Contents About the DigiClient 8.0...

More information

Animated Lighting Software Overview

Animated Lighting Software Overview Animated Lighting Software Revision 1.0 August 29, 2003 Table of Contents SOFTWARE OVERVIEW 1) Dasher Pro and Animation Director overviews 2) Installing the software 3) Help 4) Configuring the software

More information

SMS (Server Management Software) Digital Video Recorder. User s Manual

SMS (Server Management Software) Digital Video Recorder. User s Manual SMS (Server Management Software) Digital Video Recorder User s Manual Contents 1 - Introduction 2 1.1 About this manual 2 1.2 Configuration 2 1.3 SMS Functions 2 1.4 Product Information 2 1.5 System Requirements

More information

How To Use Mview On A Powerline 2.2 (Powerline) On A Pc Or Macbook 2 (Powerplst) On An Iphone Or Ipa 2 (Aldo) On Your Iphon 2 (

How To Use Mview On A Powerline 2.2 (Powerline) On A Pc Or Macbook 2 (Powerplst) On An Iphone Or Ipa 2 (Aldo) On Your Iphon 2 ( mview for V8.53 and Later Motion Software mview is an elevator monitoring application. Through 1 Ethernet, the computer running mview may be connected directly to a single Motion 2000 or Motion 4000 controller

More information

Rapid Eye. System Administrator Guide. Multi-Media Digital Video Recorder. Document 800-02953V4 Rev A 03/10

Rapid Eye. System Administrator Guide. Multi-Media Digital Video Recorder. Document 800-02953V4 Rev A 03/10 Rapid Eye Multi-Media Digital Video Recorder System Administrator Guide Document 800-02953V4 Rev A 03/10 System Administrator Guide Revisions Issue Date Revisions A 01/09 New preliminary document based

More information

PowerVideo Plus. EverFocus Central Management Software. for Networked Video Devices Management. User s Manual

PowerVideo Plus. EverFocus Central Management Software. for Networked Video Devices Management. User s Manual EverFocus Central Management Software for Networked Video Devices Management User s Manual Copyright EverFocus Electronics Corp. Release Date: January, 2013 Copyright 2012 EverFocus Electronics Corp. All

More information

Appendix A. CMS(Client Management Software)

Appendix A. CMS(Client Management Software) Appendix A. CMS(Client Management Software) A-1. Install CMS for Windows PC CMS is a program for communication between DVR and PC to control signal and video. Insert the enclosed CD, and go to CD-ROM Drive

More information

OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC. www.signalcrafters.com

OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC. www.signalcrafters.com OWNERS MANUAL Status Monitor for Windows 95, 98, ME, NT 4, 2000 & XP SIGNALCRAFTERS TECH, INC. www.signalcrafters.com 57 Eagle Rock Avenue, East Hanover, NJ 07936 Tel: 973-781-0880 or 800-523-5815 Fax:

More information

CashFlow Programming Module CPM

CashFlow Programming Module CPM CashFlow Programming Module CPM Installation & User Guide GB REV G4 08/08/2006 Table of Content Table of Content... 2 CashFlow Programming Module (CPM)... 4 What is a CPM?... 4 CPM Identification... 4

More information

Personal VoIP Gateway SKG-300 User Manual

Personal VoIP Gateway SKG-300 User Manual Personal VoIP Gateway SKG-300 User Manual 1 Copyright Copyright (C) 2005 PLANET Technology Corp. All rights reserved. The products and programs described in this User s Manual are licensed products of

More information

Mirasys NVR 5.10 Installation Guide

Mirasys NVR 5.10 Installation Guide Mirasys NVR 5.10 Installation Guide 2005-2010 Mirasys Ltd. All rights reserved. No part of this document may be reproduced for any purpose, even in part. TRADEMARKS Mirasys, Mirasys DINA, Mirasys N, Mirasys

More information

DIRECT INTERNET DATA. User s Guide

DIRECT INTERNET DATA. User s Guide DIRECT INTERNET DATA User s Guide Iridium Satellite LLC Rev. 2; June 15, 2001 DIRECT INTERNET DATA ------------------------------------------------------------------------------------- TABLE OF CONTENTS

More information

EKB200. USB Controller Keyboard. Installation / Operation Instructions. Rev. 1.0

EKB200. USB Controller Keyboard. Installation / Operation Instructions. Rev. 1.0 EKB200 USB Controller Keyboard Installation / Operation Instructions Rev. 1.0 SAFETY WARNINGS Do not place the device near to heaters, furnaces, other heat sources or under direct solar irradiation. Operate

More information

1. Central Monitoring System Software

1. Central Monitoring System Software 1. Central Monitoring System Software 1-1. General information CMS program is an application with which users not only watch and control remote DVRs, but also receive video/audio data or alarm signals

More information

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server Products: EFA with EFA Scan, DVRM and DVMD with Realtime Monitor or Stream Explorer DVMD-B1 LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server Remote control of test and

More information

How To Set Up Flir Cloud Client For Pc Or Mac Or Mac (For Pc Or Ipad) On A Pc Or Pc Or Mouse (For Mac) On An Iphone Or Ipa) On Pc Or Tv (For Ipa

How To Set Up Flir Cloud Client For Pc Or Mac Or Mac (For Pc Or Ipad) On A Pc Or Pc Or Mouse (For Mac) On An Iphone Or Ipa) On Pc Or Tv (For Ipa Instruction Manual FLIR Cloud Services Client Instruction Manual FLIR Cloud Services Client #LX400018; r. 2.0/14567/14568; en-us iii Table of contents 1 Setting up FLIR Cloud Client for PC or Mac...1

More information

ACS CLIENT SOFTWARE USER MANUAL

ACS CLIENT SOFTWARE USER MANUAL ACS CLIENT SOFTWARE USER MANUAL 1 ACS USER GUIDE 1.1 System Requirement Recommended System Requirement OS CPU VGA RAM HDD WindowXP, Vista Pentium 4, 2Ghz 1024*768, 64MB 24bit color graphic card 1GB 20MB

More information

Service Pack Release Letter MIC Series 550 System Controller 2.12.00.07. Table of Contents

Service Pack Release Letter MIC Series 550 System Controller 2.12.00.07. Table of Contents Service Pack Release Letter Table of Contents 1. Introduction 2 1.1 Disclaimer of Warranty 2 1.2 Purpose 2 1.3 Scope 2 1.4 Installation Requirements 2 2. About This Service Pack Release 2 3. Hardware Changes

More information

USER S MANUAL. AXIS Mobile Monitor

USER S MANUAL. AXIS Mobile Monitor USER S MANUAL AXIS Mobile Monitor AXIS Mobile Monitor Overview Main window Main menu Find Devices Find Devices menu Monitor window Monitor menu Sequence window Sequence menu How to Use AXIS Mobile Monitor

More information

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version

More information

NetClient software user manual

NetClient software user manual NetClient software user manual 1-1. General information Net Client is an application which provides users not only viewing and controling remote DVRs, but also receiving realtime event data or alarm signals

More information

Troubleshooting and Diagnostics

Troubleshooting and Diagnostics Troubleshooting and Diagnostics The troubleshooting and diagnostics guide provides instructions to assist in tracking down the source of many basic controller installation problems. If there is a problem

More information

IP Surveillance System. User s manual

IP Surveillance System. User s manual IP Surveillance System User s manual IP Surveillance system Table of Contents TABLE OF CONTENTS TABLE OF CONTENTS...1 SYSTEM REQUIREMENT...3 INSTALLATION...4 1. MAIN CONSOLE...12 1.1 Start...14 1.2 Information

More information

SEC-PCC10 SEC-PCC20 SEC-PCC30 PCI SECURITY CARD

SEC-PCC10 SEC-PCC20 SEC-PCC30 PCI SECURITY CARD SEC-PCC10 SEC-PCC20 SEC-PCC30 PCI SECURITY CARD ADVANCED ENGLISH MANUAL 0 Installation 1. Turn off the PC s power and unplug the power cable. 2. Open the PC s cover and plug the capture card into an empty

More information

NVMS-1200. User Manual

NVMS-1200. User Manual NVMS-1200 User Manual Contents 1 Software Introduction... 1 1.1 Summary... 1 1.2 Install and Uninstall... 1 1.2.1 Install the Software... 1 2 Login Software... 3 2.1 Login... 3 2.2 Control Panel Instruction...

More information

Networking. General networking. Networking overview. Common home network configurations. Wired network example. Wireless network examples

Networking. General networking. Networking overview. Common home network configurations. Wired network example. Wireless network examples Networking General networking Networking overview A network is a collection of devices such as computers, printers, Ethernet hubs, wireless access points, and routers connected together for communication

More information

Moxa Device Manager 2.0 User s Guide

Moxa Device Manager 2.0 User s Guide First Edition, March 2009 www.moxa.com/product 2009 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. Moxa Device Manager 2.0 User Guide The software described in this manual

More information

How To Use The Workstation Program On A Pc Or Mac Or Macbook Or Macintosh (Aero) With A Computer Or Ipa (A2) With An Ipa Or Ipad (A3) With The Powerpoint 2.

How To Use The Workstation Program On A Pc Or Mac Or Macbook Or Macintosh (Aero) With A Computer Or Ipa (A2) With An Ipa Or Ipad (A3) With The Powerpoint 2. Mirasys NVR 6.1 User s Guide CONTENTS Contents... 2 Before you start... 3 Introduction... 6 Logging in... 9 User interface... 13 Navigator... 16 Cameras... 25 Video outputs... 41 Digital outputs... 46

More information

IP Surveillance TroubleShooting Guide Version: 0.9 Release: 20060527

IP Surveillance TroubleShooting Guide Version: 0.9 Release: 20060527 IP Surveillance TroubleShooting Guide Version: 0.9 Release: 20060527 Chapter. 1. Introduction ACTi provides you a series of guides for your project from proposal stage to maintenance stage. They work

More information

NVMS - 1000 USER MANUAL. Version 2.1.0

NVMS - 1000 USER MANUAL. Version 2.1.0 NVMS - 1000 USER MANUAL Version 2.1.0 Contents 1 Software Introduction... 1 1.1 Summary... 1 1.2 Operation Environment... 1 1.3 Install and Uninstall... 2 1.3.1 Install the Software... 2 1.3.2 Uninstall

More information

SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2

SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2 SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2 USER MANUAL Rev. P1.11 September 13, 2006 DeltaV is a trademark of Emerson Process Management, Inc Emerson Process Management, Inc. 1998,

More information

UltraCade Multi-Game System Frequently Asked Questions

UltraCade Multi-Game System Frequently Asked Questions The UltraCade Frequently Asked Questions (FAQ) is a collected list of the most common questions asked by our customers. Please make sure your Tech Support team has a copy of these questions to better serve

More information

Bosch Protocol Technical Information

Bosch Protocol Technical Information Bosch Protocol Technical Information en 1 Bosch Protocol Technical Information en Application Note Bosch Protocol Technical Information en 2 1 Contents 1 Contents...2 2 Change History...2 Introduction...3

More information

Hypercom Key Loading and Management (HKLM) RS232 PPP Key Injection PC Setup Guide

Hypercom Key Loading and Management (HKLM) RS232 PPP Key Injection PC Setup Guide Hypercom Key Loading and Management (HKLM) RS232 PPP Key Injection PC Setup Guide Hypercom Corporation 8888 East Raintree Drive Scottsdale, Arizona 85260 USA Corporate Telephone: 480.642.5000 Corporate

More information

VMS A1 Client Software. User Manual (V2.0)

VMS A1 Client Software. User Manual (V2.0) VMS A1 Client Software User Manual (V2.0) Contents Chapter 1 Overview...4 1.1 Description...4 1.2 Running Environment...4 1.3 Function Modules...5 Chapter 2 Live View...7 2.1 User Registration and Login...7

More information

ivms-4500(windows Mobile) Mobile Client Software User Manual Version 1.0

ivms-4500(windows Mobile) Mobile Client Software User Manual Version 1.0 ivms-4500(windows Mobile) Mobile Client Software User Manual Version 1.0 Thank you for purchasing our product. This manual applies to ivms-4500 (Windows Mobile) mobile client software, please read it carefully

More information

Professional Surveillance System User s Manual

Professional Surveillance System User s Manual Professional Surveillance System User s Manual \ 1 Content Welcome...4 1 Feature...5 2 Installation...6 2.1 Environment...6 2.2 Installation...6 2.3 Un-installation...8 3 Main Window...9 3.1 Interface...9

More information

Maintaining the Content Server

Maintaining the Content Server CHAPTER 7 This chapter includes the following Content Server maintenance procedures: Backing Up the Content Server, page 7-1 Restoring Files, page 7-3 Upgrading the Content Server, page 7-5 Shutting Down

More information

OFFICE KEYBOARD (MT1210 & MT1405) OFFICE FEATURES

OFFICE KEYBOARD (MT1210 & MT1405) OFFICE FEATURES OFFICE KEYBOARD (MT1210 & MT1405) OFFICE FEATURES Thank you for purchasing OFFICE KEYBOARD. This User s manual contains all information that helps you to operate your keyboard. Please keep the software

More information

DataLINE Data Retrieval

DataLINE Data Retrieval Container Refrigeration INSTALLATION GUIDE for DataLINE Data Retrieval 62 10628 Rev B INSTALLATION GUIDE CONTAINER REFRIGERATION UNIT DataLINE Data Retrieval CONTENTS Paragraph Number Page 1. Introduction...

More information

Honeywell Internet Connection Module

Honeywell Internet Connection Module Honeywell Internet Connection Module Setup Guide Version 1.0 - Page 1 of 18 - ICM Setup Guide Technical Support Setup - Guide Table of Contents Introduction... 3 Network Setup and Configuration... 4 Setting

More information

PARTNER ACS R4.0 Remote Administration R4.0. Getting Started

PARTNER ACS R4.0 Remote Administration R4.0. Getting Started PARTNER ACS R.0 Remote Administration R.0 Getting Started 8-6-66 700080 Issue May 00 Copyright 00, Avaya Inc. Document 8-6-66 All Rights Reserved 700080 Printed in USA Issue May 00 Notice Every effort

More information

Quick Start Guide NVR DS-7104NI-SL/W NVR. www.hikvision.com. First Choice For Security Professionals

Quick Start Guide NVR DS-7104NI-SL/W NVR. www.hikvision.com. First Choice For Security Professionals Quick Start Guide NVR DS-7104NI-SL/W NVR NOTE: For more detailed information, refer to the User s Manual on the CD-ROM. You must use your PC or MAC to access the files. www.hikvision.com Quick Start 1.

More information

800-02577-TC 3/10 Rev. A

800-02577-TC 3/10 Rev. A 800-02577-TC 3/10 Rev. A Total Connect Online Help Guide TRADEMARKS Honeywell is a registered trademark of Honeywell International Inc. Windows and Windows Vista are trademarks, or registered trademarks

More information

DSG SoftPhone & USB Phone Series User Guide

DSG SoftPhone & USB Phone Series User Guide DSG SoftPhone & USB Phone Series User Guide Table of Contents Overview Before You Start Installation Step 1. Installing DSG SoftPhone Step 2. Installing USB Phone Step 3. System Check First Time Use Step

More information

EAGLE. PAN TILT SYSTEMS Helping to bring your world into focus. PT-C Pan Tilt Controller. Installation and Operations Manual.

EAGLE. PAN TILT SYSTEMS Helping to bring your world into focus. PT-C Pan Tilt Controller. Installation and Operations Manual. EAGLE PAN TILT SYSTEMS Helping to bring your world into focus PT-C Pan Tilt Controller Installation and Operations Manual Revision 9 10 August 2004 Distributed by Hitachi Denshi America Ltd. 150 Crossways

More information

IP SERIAL DEVICE SERVER

IP SERIAL DEVICE SERVER IP SERIAL DEVICE SERVER ( 1 / 2 / 4 serial port ) Installation guide And User manual Version 1.0 1Introduction... 5 1.1Direct IP mode...5 1.2Virtual COM mode...5 1.3Paired mode...6 1.4Heart beat... 6

More information

4 Networking Generators

4 Networking Generators 4 Networking Generators Topics in this chapter: Overview Configuring a file server Establishing a network environment Network operations Controlling a generator remotely Upgrading generators over a network

More information

USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks

USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St. Neihu,

More information

for Windows Media Center User's Guide

for Windows Media Center User's Guide for Windows Media Center User's Guide Table of Contents Introduction System Requirements Installation Running HAI Home Control Using HAI Home Control Product Support Introduction Thank you for purchasing

More information

Information in this document, including URL and other Internet Web site references, is subject to change without notice. Unless otherwise noted, the

Information in this document, including URL and other Internet Web site references, is subject to change without notice. Unless otherwise noted, the Information in this document, including URL and other Internet Web site references, is subject to change without notice. Unless otherwise noted, the example companies, organizations, products, domain names,

More information

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation Quick Installation A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding This chapter intends to get your new FuzzyScan scanner working with your existing system within minutes. General instructions

More information

INTELLECT TM Software Package

INTELLECT TM Software Package AxxonSoft INTELLECT TM Software Package Quick Start Guide Version 1.0.0 Moscow 2010 1 Contents CONTENTS... 2 1 INTRODUCTION... 3 1.1 Document purpose... 3 1.2 Purpose of the Intellect software package...

More information

Network Viewing Software User and Administrators Guide

Network Viewing Software User and Administrators Guide Network Viewing Software User and Administrators Guide Contents Contents...2 Introduction...3 System requirements...3 Connecting through a firewall....3 Connecting using a proxy server....3 Using Network

More information

Network Scanner Tool R3.1. User s Guide Version 3.0.04

Network Scanner Tool R3.1. User s Guide Version 3.0.04 Network Scanner Tool R3.1 User s Guide Version 3.0.04 Copyright 2000-2004 by Sharp Corporation. All rights reserved. Reproduction, adaptation or translation without prior written permission is prohibited,

More information

MJPEG Camera Client User Manual

MJPEG Camera Client User Manual MJPEG Camera Client User Manual CONTENTS User Manual 1 WELCOME... 3 1.1Features... 3 1.2Installation Requirements... 3 1.3 Software Installation... 3 2 Software Operation... 5 2.1 Tab bar... 6 2.2 Device

More information

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL Rev. D PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL 10 BORIGHT AVENUE, KENILWORTH NEW JERSEY 07033 TELEPHONE: 800-524-0273 FAX: 908-686-9317 TABLE OF CONTENTS Page

More information

1. Central Monitoring System Software

1. Central Monitoring System Software 1. Central Monitoring System Software 1-1. General information CMS program is an application with which users not only watch and control remote DVRs, but also receive video/audio data or alarm signals

More information

CM6700 Matrix Switcher/Controller

CM6700 Matrix Switcher/Controller CM6700 Matrix Switcher/Controller Installation/ Operation Manual C523M-H (6/05) Pelco 3500 Pelco Way Clovis, CA 93612-5699 USA www.pelco.com In North America and Canada: Tel (800) 289-9100 FAX (800) 289-9150

More information

SMART Board Interactive Whiteboard Setup with USB Cable

SMART Board Interactive Whiteboard Setup with USB Cable SMART Board Interactive Whiteboard Setup with USB Cable The instructions below are for the SMART Board interactive whiteboard 500 series and apply to both desktop and laptop computers. Ready Light USB

More information

Installing Windows XP Professional

Installing Windows XP Professional CHAPTER 3 Installing Windows XP Professional After completing this chapter, you will be able to: Plan for an installation of Windows XP Professional. Use a CD to perform an attended installation of Windows

More information

WV-AS65. Operating Instructions. Disk Recorder Management Software PC Software Package. Model No.

WV-AS65. Operating Instructions. Disk Recorder Management Software PC Software Package. Model No. Disk Recorder Management Software PC Software Package Operating Instructions Model No. WV-AS65 Before attempting to connect or operate this product, please read these instructions carefully and save this

More information