1 City of Friendswood FY 2010 Capital Improvements Program - Water & Sewer Projects 5-Year CIP PROJECT ESTIMATED COST ESTIMATED COUNCIL IDENTIFIED FUNDING SOURCES STRATEGIC COMPLETION INITIATIVES FM 2351/Beamer Road Utilities (Phase 1) $ 1,372, FY 2011 $ 2,000, EDA Grant Zero - Two Yrs; D Second Take Point Phase 2 $ 1,556, FY 2012 $ 2,297, W&S Bonds N/A Water Plant #5 Replacement $ 3,277, FY 2012 $ 3,277, W&S Bonds N/A Water Plant #6 Replacement $ 1,106, FY 2011 $ 1,040, W&S Bonds N/A COH Raw Water System Buy-In $ 3,500, FY 2011 $ - COH Contract N/A Lift Station #3 Replacement $ 735, FY 2012 $ - N/A N/A Lift Station #6 Replacement $ 356, FY 2012 $ - N/A N/A Water Plant #7 Replacement $ 1,625, FY 2012 $ - N/A N/A Water Plant #2 Replacement $ 879, FY 2012 $ - N/A N/A Blackhawk WasteWater Treatment Plant Rehab $ 2,429, FY 2012 $ - N/A N/A Second EST Rehabilitation $ 372, FY 2014 $ - N/A N/A East FM 528 Water Line $ 1,828, FY 2015 $ - N/A N/A Forty-Two Inch Water Main Replacement $ 2,291, FY 2015 $ - COH Contract N/A Total Estimates $ 21,327, $ 8,614, Council Strategic Initiatives Zero - Two Years A. MYFP B. Drainage/Streets C. Sports Fields D. Panhandle Infrastructure E. ISD Partnership Needs One - Five Years A. Pavement Master Plan B. Animal Control Facility C. Library Expansion D. Expanding Activity Ctr E. Continue Drainage Imp
2 Beamer Road Infrastructure Phase I Community Development Planning Document: North Panhandle Service Plan II TYPE: Utility YEAR PLANNED: 2011 SUBTYPE: Sanitary Sewer Improvements PROJECT NUMBER: US0021 This is a phased project based on expectations for economic development activities in the northern panhandle area of town. This project is based on a service plan completed in April 2000 and follows the recommendation for Service Plan II in a phased implementation. This initial phase creates the primary subservice area along the north side of FM 2351 and consists of approximately 4250 lf of 12 inch gravity sewer, a large lift station, an 8 inch force main towards the southwest crossing beneath FM 2351 at a point near Wandering Trail, and an 8 inch water line. FUNDING: This area has been zoned an Industrial District. Efforts to attract light industry and office warehouse business and development into this area are largely dependent on availability of City service infrastructure. In 2009, the City secured a grant from the U.S. Economic Development Administration for this project. Phase One of this project is envisioned to meet the needs of initial development along FM2351 east to Beamer Rd and to be expandable, through Phases Two and Three, to meet requirements of future development of the area as it grows. Funding has been allocated for this project from a 2009 EDA Grant. Estimated Project Costs $1,372,320
3 Second Take Point Phase II Planning Document: Ground Water Reduction Plan SUBTYPE: Water Distribution Improvements PROJECT NUMBER: UW0521 The improvements proposed in Phase II of the second take point is the construction of (1) a one million gallon concrete storage tank; (2) an additional pumping unit; (3) electrical upgrades; (4) control system modifications; (5) additional yard piping; (6) a modification to the existing storage tank fill devices with controls; (7) an addition of a second storage tank fill devices with controls; (8) replacement of flow measurement unit; (9) improvements to the building ventilation/air conditioning system; and (10) relocation and modification of SCADA system and the addition of one variable speed pump capable of delivering 4,000 GPM. FUNDING: The completion of the Phase II of the second take point will allow the increased operations of this site in accordance to The Ground Water Reduction Plan. Funding has been allocated for this project from 2009 Revenue Bonds. Estimated Project Costs $1,372,320
4 Water Plant Number Five Rehabilitation Planning Document: None SUBTYPE: Water Distribution Improvements PROJECT NUMBER: UW0018 This rehabilitation will include the replacement of control room, chemical room, conversion of pumps, and ground storage tank as necessary. Replacement of the elevated storage tank will be necessary. Additionally, the project scope will include the replacing of all valves and piping as necessary. The existing cyclone fence will be replaced with 8 feet cedar wood. The existing ground storage tank is made of steel with a capacity of 210,000 gallons. The ground storage tank should be replaced with a 500,000-gallon capacity unit. The control room is in need of modification to eliminate water damage due to rainfall intrusion. FUNDING: This site contains the one million gallon elevated storage tank. The existing ground storage tank leaks from the bottom plates and requires extensive repairs. The ground storage tank is 32 years old and is in need of replacement, possibly with a new 500,000-gallon unit. The existing control room facility is extremely small and floods easily. Existing controls are aging to the point of needing total replacement. Correcting this will require modification of this building and the surrounding area. The vertical turbine pumps should also be replaced within this project with horizontal units to improve operation efficiency. Funding has been allocated for this project from 2009 Revenue Bonds. Estimated Project Costs $3,277,000
5 Water Plant Number Six Rehabilitation Planning Document: None TYPE: Utility YEAR PLANNED: 2011 SUBTYPE: Water Distribution Improvements PROJECT NUMBER: UW0019 The rehabilitation will include the replacement of control room, chemical room, conversion of pumps, and half million-gallon ground storage tank. Additionally, the project scope will include the replacing of all valves and piping. The existing cyclone fence will be replaced with 8 feet cedar wood. The existing tank is galvanized steel with a capacity of only 210,000 gallons. FUNDING: The well site is in need of a new control room. The existing controls are located in an extremely small room and are aging to the point of needing total replacement. The tank is thirty-two (32) years old and is in need of total rehabilitation. The vertical turbine pumps will be replaced with horizontal units to provide more efficient operation. The ground storage tank will be replaced with a one half million gallon tank to provide more storage capacity. Funding has been allocated for this project from 2009 Revenue Bonds. Estimated Project Costs $1,106,620
6 COH Raw Water System Buy-In Planning Document: Ground Water Reduction Plan TYPE: Utility YEAR PLANNED: 2011 SUBTYPE: Purchase PROJECT NUMBER: UW0501 This is a purchase of raw water capacity from the City of Houston through their centralization of the Raw Water feed system to the Southeast Water Purification Plant. The City of Houston has for years operated and maintained their raw water collection and distribution system used for providing the water supply to treatment facilities individually. A decision was taken recently to share the costs of operations, maintenance and improvements out among the municipal customer-participants currently acting as co-owners in the treatment and transmission facilities. In order for Houston to continue supplying raw water in future and prevent the sole burden of the cost being shared only by Houston all future co-participants desire more capacity are to share the cost. In order to do this fairly, all raw water supplies are group to create a raw water system with a 240 MGD capacity. This is a component of the Surface Water supply-treatment and distribution system that the City has bought into as an outgrowth of the 2001 Ground Water Reduction Plan. The City of Houston is sharing out the cost of this system with its co-participants. Estimated Project Costs $3,500,000
7 Lift Station #3 Replacement Planning Document: Utility Master Plan SUBTYPE: Lift Station Improvements PROJECT NUMBER: N/A This project would replace the existing lift station that serves the Annalea- Kingspark-Whitehall area. A new wet well would be poured, new pumps and controls for the lift station would be installed and new fencing will be erected. The existing lift station at Annalea/Kingspark/Whitehall has reached the end of its useful life span and is in need of replacement. Current estimates indicate that this system will be severely taxed and incapable of handling even normal combined flows in the next few years. Estimated Project Costs $735,000
8 Lift Station #6 Replacement Planning Document: Utility Master Plan SUBTYPE: Lift Station Improvements PROJECT NUMBER: N/A This project would replace the existing lift station that serves the Regency Estates area. A new wet well would be poured, new pumps and controls for the lift station would be installed, and new fencing erected. The existing lift station at Regency Estates has reached the end of its useful life span and is in need of replacement. Current estimates indicate that this system will be severely taxed and incapable of handling even normal combined flows in the next few years. Estimated Project Costs $356,000
9 Water Plant Number Seven Rehabilitation Planning Document: None SUBTYPE: Water Distribution Improvements PROJECT NUMBER: UW0026 The rehabilitation will include the replacement of control room, chemical room, conversion of pumps, and ground storage tank as necessary. Replace all valves and piping as necessary. The existing cyclone fence will be replaced with 8 feet cedar wood. The existing tanks are made of galvanized steel with a capacity of 210,000 gallons and 63,000 respectably and may require replacement with one half-million gallon tank. Final recommendation to come out of a PER. Recondition existing generator set. This well site is in need of a new control room. The existing room is too small for safety when performing electrical repair work and no longer meets NEC Codes. The existing switchgear is at the end of its usable life. The room also floods when there is any rainfall. A new control room/chemical room will eliminate this situation. A replacement of the existing vertical turbine pumps with horizontal units would provide a more efficient operation. The ground storage tanks should be replaced as necessary with half million gallon ground storage as dictated by the last ground storage tank inspection. At this time the replacement of all needed piping and accessories should be done. The existing automatic transfer switch at the site was hit by lightening and partially destroyed. A new switch would enable this site to automatically transfer power when needed. Reconditioning the existing generator set including increasing the diesel tank capacity would make this emergency power system more reliable. Estimated Project Costs $1,625,300
10 Water Plant Number Two Rehabilitation Planning Document: None SUBTYPE: Water Distribution Improvements PROJECT NUMBER: UW0017 The rehabilitation of Plant #2 will include the replacement of control room, chemical room, conversion of pumps and the probable replacement of the ground storage tank as necessary. Replacement of all valves and piping as necessary. The existing cyclone fence will be replaced with an 8 foot cedar wood fence. This well site is in need of a new control room. The existing controls are located outside and are showing the effects of that environment. The tank is 41 years old and made from galvanized steel with a capacity of only 210,000 gallons and is in need of total rehabilitation. The vertical turbine pumps will be replaced with horizontal units to provide more efficient operation. Estimated Project Costs $879,000
11 Blackhawk Treatment Plant Rehab Sponsor Department COUNCIL GOALS: #2 Improve Infrastructure PLANNING DOCUMENT: Waste Water Flow Study SUBTYPE: Wastewater Treatment Improvements PROJECT NUMBER: NYA This project consists of the rehabilitation of (1) the head works structure; (2) mechanical bar screens; (3) aeration blowers, piping and valves; (4) fine bubble diffusers; (5) media filters; and (6) UV disinfectant system. The Blackhawk Wastewater Treatment Facility is a facility owned and operated by the Gulf Coast Waste Disposal Authority. In 2010, the GCWDA commissioned an assessment of the facility and identified areas needing repair. Friendswood is the majority capacity owner within the plant. Estimated Project Costs $2,429,653
12 Second Elevated Water Storage Tank Rehabilitation PLANNING DOCUMENT: None TYPE: Utility YEAR PLANNED: 2014 SUBTYPE: Water Plant Improvements PROJECT NUMBER: NYA The rehabilitation of the existing elevated storage tank will include the sand blasting and painting of the storage tank and some minor repairs to pumping equipment. A preventive maintenance program would prolong the life of the facilities. The ground storage needs to be painted every 10 to 12 years to assure its integrity and usefulness. Estimated Project Costs $372,000
13 East FM 528 Waterline Planning Document: None SUBTYPE: Water Distribution Improvements PROJECT NUMBER: NYA This project consists of the installation of 2,850 linear feet of fourteen-inch waterline that would extend water service to the East Service Area, and then loop the line back into the existing system by installing 6,600 linear feet of twelve-inch waterline down to Bay Area Boulevard. The Water Distribution System is stretched thin when it gets beyond Bay Area Boulevard, south of FM 528. There are also not enough loops back to sustain pressure in this area. This will give potable water to the eastern most area of the City and loop the FM 528 line to the Bay Area Boulevard line. Estimated Project Costs $1,828,000
14 42 Inch Water Main Replacement Planning Document: None TYPE: Utility YEAR PLANNED: 2015 SUBTYPE: Water Distribution Improvements PROJECT NUMBER: NYA This is a co-participation project with the City of Houston and other participants in the upgrade of the main north / south surface water transmission pipeline from the Southeast Water Purification Plant along State Highway 3. Texas Department of Transportation plans to widen State Highway 3 and it will be necessary to remove the existing pipeline from the State right-of-way in preparation for that project. This presents an opportunity to up-size this transmission line when it is removed from the easement. The removal / construction project will be managed by the City of Houston and Participant s cost share will be based on a pro-rata use according to their distribution allocation. Friendswood s distribution allocation from this line is balanced by its distribution allocation from the 36-inch line on Beamer. Replacement and movement of the 42-inch line to a location outside of the Highway 3 ROW is planned for completion by 2015 in order for TxDOT s project to proceed on schedule. The City of Friendswood is a participant in the operation and maintenance of the 42 inch Water Line. That pro-rata participation is reduced by its participation in the Beamer Road 36 inch transmission line. The City is dependent on these as the source of surface water required to meet the Ground Water Reduction Plan as established in 2001, and to meet growing population requirements through build-out. Estimated Project Costs $2,291,000
PROJECT NAME BACKGROUND STATUS
Utilities Department Projects This report reflects the status of Utility Capital Improvement Projects, Rehabilitation and Maintenance Programs of the City s water, wastewater, and reclaimed infrastructure
More information2012 2016 Capital Improvement Plan City of Houston WASTEWATER TREATMENT FACILITIES
2012 2016 Capital Improvement Plan City of Houston WASTEWATER TREATMENT FACILITIES 2012 2016 Capital Improvement Plan City of Houston WASTEWATER TREATMENT FACILITIES The Wastewater Treatment System (System)
More informationTOWN OF SURFSIDE UTILITY UPGRADE PROJECT Project Completion
TOWN OF SURFSIDE UTILITY UPGRADE PROJECT Project Completion Project Overview Sanitary Sewer System 2 Town of Surfside Project Overview Potable Water System 3 Town of Surfside Project Overview Storm Water
More informationFISCAL YEAR 2014-2018 CAPITAL IMPROVEMENT PLAN WASTEWATER TREATMENT FACILITIES
FISCAL YEAR 2014-2018 CAPITAL IMPROVEMENT PLAN WASTEWATER TREATMENT FACILITIES 1 FISCAL YEAR 2014-2018 CAPITAL IMPROVEMENT PLAN Wastewater Treatment Facilities The Wastewater Treatment System (System)
More informationCITY OF WASHINGTON SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN
CITY OF WASHINGTON SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN Adopted October 5, 2009 Table of Contents Chapter Description Page 1 Facility Descriptions... 3 1.1 Municipal Power Plant, 1001 Park
More informationDeSoto County is not a water service provider and does not operate any
Water and Sewer DeSoto County is not a water service provider and does not operate any water delivery systems. There are 14 certificated, non-municipal water associations operating in the county that are
More informationAnn Arbor Wastewater Treatment Plant Facilities Renovations Project September 2015
Ann Arbor Wastewater Treatment Plant Facilities Renovations Project September 2015 The Facilities Master Plan was completed in 2004 and identified the need for improvements to the City of Ann Arbor s Wastewater
More informationThe checklist utilized by the Authority will be similar to that which is shown below. Project Name: Location: Consulting Engineering Firm:
Page 1 of 6 Section 1. PURPOSE This policy is an Engineering checklist of the Local Review Program for sanitary sewer improvement projects by the Bedford Regional Water Authority ( Authority ). Section
More informationTerms of Reference. Aqaba Water and Wastewater Utility Asset Valuation
Technical Support for Procurement and Project Management and Private Sector Participation to the Ministry of Water and Irrigation, Water Authority of Jordan and the Jordan Valley Authority Support for
More informationKansas City s Overflow Control Program
Kansas City s Overflow Control Program Kansas City Water Services Water Wastewater Stormwater 2 Water Services Department 1000 Positions 835 Employees 3 Utilities FY 13/14 Budget = $307 million Water Wastewater
More informationAsset Management Answering the 5 Core Questions
Asset Management Answering the 5 Core Questions by Timothy Taber, PE Barton & Loguidice Page 1 Drivers Asset Management Case Study 1. What is the current state of my assets? 2. What is my required sustainable
More informationTexas Commission on Environmental Quality Page 1 Chapter 217 - Design Criteria for Domestic Wastewater Systems
Texas Commission on Environmental Quality Page 1 217.31. Applicability. SUBCHAPTER B: TREATMENT FACILITY DESIGN REQUIREMENTS 217.31-217.39 Effective August 28, 2008 This subchapter details the design values
More informationSession: HDPE Pipe Test Rafael Ortega, Vice President, Lockwood, Andrews & Newnam
Session: HDPE Pipe Test Rafael Ortega, Vice President, Lockwood, Andrews & Newnam Education Master of Business Administration University of Houston, 1985 Bachelor of Science, Civil Engineering University
More informationPART 6 - STANDARD DESIGN AND CALCULATION FORMS 6.1 SANITARY SEWER DATA SHEET
PART 6 - STANDARD DESIGN AND CALCULATION FORMS 6.1 SANITARY SEWER DATA SHEET Name of Municipality or Sewer District Name of Project Original Township and Lot Number Name of Engineer of Firm Preparing Plans
More informationDIVISION OF WATER QUALITY CONSTRUCTION GRANTS & LOANS SECTION FAST TRACK AUDIT CHECKLIST
DIVISION OF WATER QUALITY CONSTRUCTION GRANTS & LOANS SECTION FAST TRACK AUDIT CHECKLIST CERTIFICATION 1. Did the engineer submit a certificate of completion utilizing the appropriate page of the issued
More informationSECTION 3 SANITARY SEWER DESIGN
SECTION 3 SANITARY SEWER DESIGN 3.1 GENERAL DESIGN CRITERIA 3.1.1 Requirement for Sanitary Sewer 3.1.2 Design Approval 3.1.3 IEPA Permit Required 3.1.4 Differentiation Between Public and Private Sanitary
More informationSpecifications for Residential Property Owners Connection to New Public Sewer
Specifications for Residential Property Owners Connection to New Public Sewer Spalding Tract property owners are required to connect to the community sewer system when construction is complete and the
More informationGlen Hills Area: Septic System and Public Sewer Q & A Information Sheet Page 1
Glen Hills Area: Septic System and Public Sewer Q & A Information Sheet Page 1 The Montgomery County Dept. of Environmental Protection, in cooperation with the Dept. of Permitting Services and the Washington
More informationMAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT
Record MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT Abandoned Gravity Private Combined Gravity Private Foul Gravity Private Surface Water Gravity Public Combined Gravity Public Foul Gravity Public
More informationCity of Cape Coral, Florida FY 2015-2017 Proposed Operating Budgets
FUNDED CAPITAL IMPROVEMENT PROGRAM FY 2015-2020 SUMMARY OF REQUIRED REVENUES FY 2015 FY 2016 FY 2017 FY 2018 FY 2019 FY 2020 TOTAL All Hazards $ 100,000 $ - $ - $ - $ - $ - $ 100,000 Capital Facility Expansion
More informationZIONSVILLE WASTEWATER DEPARTMENT 10-YEAR SEWER REHABILITATION REPORT 2013-2022
ZIONSVILLE WASTEWATER DEPARTMENT 10-YEAR SEWER REHABILITATION REPORT 2013-2022 Town of Zionsville, Indiana December 19, 2012 PREPARED BY BEAM, LONGEST & NEFF, LLC. 8126 Castleton Road Indianapolis, Indiana
More informationM I D W E S T S O C I E T Y F O R T R E N C H L E S S T E C H N O L O G Y. Kansas City, Missouri s Trenchless Program
M I D W E S T S O C I E T Y F O R T R E N C H L E S S T E C H N O L O G Y Kansas City, Missouri s Trenchless Program Outline of Presentation Intro to Kansas City Water Services information Trenchless Program
More informationMINUTES OF MEETING OF BOARD OF DIRECTORS March 17, 2015
MINUTES OF MEETING OF BOARD OF DIRECTORS March 17, 2015 THE STATE OF TEXAS COUNTY OF HARRIS HARRIS COUNTY MUNICIPAL UTILITY DISTRICT NO. 55 The Board of Directors (the Board ) of Harris County Municipal
More informationAffordable Asset Management Workshop Making Use of the Data You Have An Owners Perspective
Affordable Asset Management Workshop Making Use of the Data You Have An Owners Perspective Building the Foundation for an Effective Asset Management Program Scott D. Kelly, P.E. Assistant City Administrator
More informationAPPENDICES G) DETAILED BACKBONE INFRASTRUCTURE CONSTRUCTION COST ESTIMATE SUMMARY
ALAMEDA POINT MASTER INFRASTRUCTURE PLAN March 31, 2014 APPENDICES G) DETAILED BACKBONE INFRASTRUCTURE CONSTRUCTION COST ESTIMATE SUMMARY Carlson, Barbee & Gibson, Inc. Backbone Infrastructure Engineer
More informationProposed standard significant deficiency language is provided in italics. Notes to staff are provided in blue and are [bracketed].
Significant Deficiencies: A Quick Fact Sheet for Hawaii PWSs Definition: Significant deficiencies are currently defined in HAR 11-20-46.1 as any defect in a system s design, operation and maintenance,
More informationDEPARTMENT OF ENVIRONMENTAL QUALITY
PROJECT IDENTIFICATION DEPARTMENT OF ENVIRONMENTAL QUALITY City of Burton Sanitary Sewer Collection System Improvements State Revolving Fund (SRF) Environmental Assessment April 2015 Applicant: Authorized
More informationRECOMMENDED PROGRAM FOR WELL AND SEPTIC SYSTEM REAL ESTATE TRANSACTION INSPECTIONS
Contra Costa Environmental Health 2120 Diamond Blvd., Suite 200 Concord, CA 94520 Phone: (925) 692-2500 Fax: (925) 692-2504 www.cchealth.org/eh/ RECOMMENDED PROGRAM FOR WELL AND SEPTIC SYSTEM REAL ESTATE
More informationAREA: 2.37 acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 LF. Single-family, Non-conforming machine shop
FILE NO.: Z-8958 NAME: Rock Structure Repair Short-form PID LOCATION: Located at 8024 Stanton Road DEVELOPER: Rock Structure Repair Attn. Rudy Gutierrez 3 Kipling Court Little Rock, AR 72209 ENGINEER:
More informationWWTP RETROFIT. Smith & Loveless Inc. www.smithandloveless.com. Also in this issue: Do You Have Emergency Backup? Aging Clarifiers Retrofit to Like New
Winter 2010 Issue #04-06-759 Rehabilitate your aging infrastructure quickly and increase your treatment capacity. Also in this issue: Do You Have Emergency Backup? Aging Clarifiers Retrofit to Like New
More informationTampa Bay Seawater Desalination Plant
Tampa Bay Seawater Desalination Plant Project History How The Plant Works Desal Fun Facts 2575 Enterprise Road, Clearwater, FL 33763-1102 Phone: 727.796.2355 / Fax: 727.791.2388 www.tampabaywater.org Tampa
More informationMoving Ruston Forward. City of Ruston Infrastructure Maintenance and Improvements
Moving Ruston Forward City of Ruston Infrastructure Maintenance and Improvements MLK Extension Project will be done in conjunction with proposed water and sewer improvements Connect Martin Luther King
More informationREQUEST FOR PROPOSALS SANITARY SEWER MAINTENANCE SERVICES FOR THE TOWN CENTER SEWER ASSESSMENT DISTRICT WITHIN THE TOWN OF WOODSIDE
REQUEST FOR PROPOSALS SANITARY SEWER MAINTENANCE SERVICES FOR THE TOWN CENTER SEWER ASSESSMENT DISTRICT WITHIN THE TOWN OF WOODSIDE Submit Proposals to: Town of Woodside Public Works Department 2955 Woodside
More informationCRS Report for Congress
Order Code RS22285 Updated March 22, 2006 CRS Report for Congress Received through the CRS Web Hurricane-Damaged Drinking Water and Wastewater Facilities: Impacts, Needs, and Response Summary Claudia Copeland
More informationTownship of Enniskillen. Asset Management Plan
Township of Enniskillen Asset Management Plan 2014 1 TABLE OF CONTENTS Page A. Introduction 3 B. State of Local Infrastructure 4 C. Desired Levels of Service 7 D. Asset Management Strategy 8 E. Financing
More informationWATER & SEWER LINE REPLACEMENT PROJECT Downtown Tempe Neighborhoods
WATER & SEWER LINE REPLACEMENT PROJECT Downtown Tempe Neighborhoods NEIGHBORHOOD MEETING Wednesday, February 10, 2016 6:00 7:00 p.m. Childsplay, 900 S. Mitchell Drive, Tempe, AZ Neighborhood Meeting Welcome,
More informationBrushy Creek Municipal Utility District (the District) Brushy Bend Waterline Replacement Project Community Meeting February 6, 2014
Brushy Creek Municipal Utility District (the District) Brushy Bend Waterline Replacement Project Community Meeting February 6, 2014 Recap of Question & Answer Session Sorted by topic not necessarily in
More informationTown of New Castle Utility Department Introduction
Town of New Castle Utility Department Introduction Town of New Castle Utility Department Mission Statement Our commitment is to ensure that our customers receive high quality water and wastewater treatment
More informationSEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT
SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT The following are minimum requirements for installation of conventional trench sewage disposal systems in St. Mary s County,
More informationCertificate of Registration
Certificate of Registration This is to certify that Clancy Docwra Limited Supplier Number: 061973 are now fully registered as a supplier on UVDB for the following products/services 1.4.25 Communication
More informationColumbus State Community College MASTER PLANNING
Columbus State Community College MASTER PLANNING Current State Facilities and Utilities Assessment November 2011 Columbus State Community College MASTER PLANNING EXISTING UTILITIES AND FACILITIES ASSESSMENT
More informationRepaired 24 Mainline Leaks
Agenda 1. Improvements & Repairs within the last year 2. Capital Improvement Project Update 3. Status of Water Supply & the Drought 4. Website Updates 5. Questions? 1 Repaired 24 Mainline Leaks Majority
More informationCHAPTER 8 CIVIL DESIGN
CHAPTER 8 CIVIL DESIGN A. GENERAL This Chapter includes standards and design considerations for other civil engineering design in structural, drainage and utilities. Design considerations for electrical
More informationSECTION 810 SEWER LINE CLEANING
SECTION 810 SEWER LINE CLEANING I. GENERAL 1.1 DESCRIPTION OF WORK The work covered by this section consists of providing all labor, equipment, material and supplies and performing all operations required
More informationAppendix S Pump Station Evaluation
Appendix S Pump Station Evaluation Technical Memorandum Date: October 12, 2001 To: Re: Orange County Utilities Task 6.4 Raw Wastewater Pump Stations 1.0 Summary In accordance with Task 6.4 of the Orange
More informationCity of Bakersfield Public Works Department Sewer System Management Plan December 2014
City of Bakersfield Public Works Department Sewer System Management Plan December 2014 C:\Users\hmayberry\Desktop\SEWER SYSTEM MANAGEMENT PLAN 2014.doc 1 Sewer System Management Plan Index: Section 1 Goals
More informationMonterey Regional Water Pollution Control Agency. Sewer System Management Plan
Monterey Regional Water Pollution Control Agency Sewer System Management Plan March 31, 2013 Sewer System Management Plan Introduction I. Goals II. Organization III. Legal Authority IV. Operation and Maintenance
More informationWastewater Collection Practice Test #3 Page 1 of 15
Wastewater Collection Practice Test #3 Page 1 of 15 1) A 54 in. storm sewer flowing half full, at a velocity of 1.35 Ft./sec., will discharge how much flow into a creek in MGD? 13.85 MGD 10.73 MGD 1.85
More informationSUMP PUMP. City of Ann Arbor & C O L L E C T I O N S Y S T E M G L O S S A R Y
Foundation A foundation is the bottom part of a building. It s the element that anchors the building to the ground and transmits the building s gravity load directly to the earth. Water damage weakens
More informationBefore H 2 Town of South Windsor, CT Evaluates Large Diameter Concrete Pipe
Before H 2 Town of South Windsor, CT Evaluates Large Diameter Concrete Pipe September 11, 2012 NEWEA Collection Systems Conference Presented by: Laurie L. Perkins, PE Dennis A. Dievert, PE C. Frederick
More informationChapter 9 Sanitary Sewers
Chapter 9 Sanitary Sewers S:/Engineering/Design Standards/Chapter 9 12/29/2014 Section 9.1 Topic General Requirements Chapter 9 Sanitary Sewers Page 9-1 9.2 Plan Submittals 9-1 9.3 Determination of Flow
More informationTOWN OF ELLETTSVILLE BYNUM FANYO UTILITIES INC. OPERATIONS MANAGEMENT SUMMARY 1995-2015
Bynum Fanyo Utilities Inc. Town of Ellettsville Operational Summary March 2016 TOWN OF ELLETTSVILLE BYNUM FANYO UTILITIES INC. OPERATIONS MANAGEMENT SUMMARY 1995-2015 Prior to September 1995 when Bynum
More informationMaricopa Association of Governments. Technical Memorandum No. 1 INFRASTRUCTURE DEVELOPMENT COSTS. August 2001
Maricopa Association of Governments Technical Memorandum No. 1 INFRASTRUCTURE DEVELOPMENT COSTS August 2001 3033 NORTH 44TH STREET, SUITE 101 PHOENIX, ARIZONA 85018 (602) 263-9500 FAX (602) 265-1422 Technical
More informationSeptic System. Responsibility! Is Your. You should know that:
Southwest Florida Water Management District Septic System Your Is Your Responsibility! PIPE SEPTIC TANK DRAIN FIELD SOIL You should know that: As a homeowner you re responsible for maintaining your septic
More informationSECTION 6 EXISTING WASTEWATER MANAGEMENT SYSTEMS
SECTION 6 EXISTING WASTEWATER MANAGEMENT SYSTEMS This section will describe the Town s existing wastewater management systems. This includes on-site disposal systems and private collection systems. The
More informationecmar SECTION INSTRUCTIONS: Sanitary Sewer Collection Systems
ecmar SECTION INSTRUCTIONS: Sanitary Sewer Collection Systems Please see the DEFINITIONS of terms at the end of this section. If you have any questions about these definitions, do not understand a question,
More informationComponents of a Basement Flooding Protection Plan: Sewer System Improvements. November 2000
Components of a Basement Flooding Protection Plan: Sewer System Improvements November 2000 Components of a Basement Flooding Protection Plan: Sewer System Improvements November 2000 SEMCOG 2000 Prepared
More informationThe City of Basehor, Kansas
The City of Basehor, Kansas Residential and Miscellaneous Permits This list provides general information regarding permit requirements for various residential construction and maintenance activities. The
More informationSANITARY SEWER SPECIFICATIONS
SANITARY SEWER SPECIFICATIONS OCTOBER 2003 HARVEST-MONROVIA WATER, SEWER, AND FIRE PROTECTION AUTHORITY SECTION 1.00 1.10 Purpose The purpose of this document is to assemble the sewer specifications, policies,
More informationGUIDANCE FOR DEVELOPMENT OF SPILL AND SLUG PREVENTION CONTROL PLANS AND FACILITIES FOR THE CITY OF ATTLEBORO SEWER USERS
Company Name: Address: The City of Attleboro s Rules and Regulations for the use of Wastewater Facilities require each user to provide protection from accidental discharge of prohibited materials and substances
More informationCapital Improvement Plan Utilities-Wastewater
Capital Improvement Plan Utilities FY14 Existing Inventory The Utilities Division of the Public Works currently serves an estimated 24,890 residential and nonresidential wastewater customers. Average daily
More informationAsset management it s a simple concept. Know your system s
Asset Management for Small Communities The Village of Weedsport Story by Timothy Taber and James Saroodis Asset management it s a simple concept. Know your system s assets equipment, pipes, machinery and
More informationB.S. in Environmental Engineering, minor in Chemistry, Oregon State University, Corvallis, Oregon, 2001
Gregory M. Hall, PE, QSD/QSP Project Engineer Oscar Larson & Associates REGISTRATION: EDUCATION: Civil Engineer #73260, California B.S. in Environmental Engineering, minor in Chemistry, Oregon State University,
More informationDoes Part of My Basement Floor Have to Be Removed to Install. Where Does the Water from the Sump Pump Go?...Page 5
PROTECTIVE PLUMBING - WHAT IS IT? TABLE OF CONTENTS Protective Plumbing What is it?...page 1 What is Foundation Drainage?...Page 2 What is a Sump Pumping System?...Page 4 Does Part of My Basement Floor
More information12/8/2014. Brought To You By: This webcast is sponsored by NASSCO with the support of IPBA.
Brought To You By: This webcast is sponsored by NASSCO with the support of IPBA. 1 Pipe Bursting A Mature and Diverse Trenchless Technology December 10, 2014 1:00 3:00 pm Eastern How to Participate Today
More informationOPERATIONS & MAINTENANCE FY 2012-2013 Adopted Budget
SERVICE DESCRIPTION To maintain all of the transferred and accepted infrastructure within the district including water, wastewater, and stormwater systems, streetlights, traffic signals, and landscaping
More informationSANITARY SEWER BACKUP. Causes & Prevention
SANITARY SEWER BACKUP Causes & Prevention A. PURPOSE The purpose of this publication is twofold: 1. It provides homeowners with basic information on the causes of sanitary sewer backups. 2. It provides
More informationSan Antonio Water System Standard Specifications for Construction ITEM NO. 1103 POINT REPAIRS AND OBSTRUCTION REMOVALS
ITEM NO. 1103 POINT REPAIRS AND OBSTRUCTION REMOVALS 1103.1 DESCRIPTION: 1. Repair of sanitary sewer lines by replacing short lengths of failed pipe with new pipe. 2. Repair of service laterals located
More informationBOARD OF COUNTY COMMISSIONERS OKALOOSA COUNTY, FLORIDA DEPARTMENT/PROGRAM: WATER & SEWER ENTERPRISE FUND/WATER OPERATIONS
WATER AND SEWER BOARD OF COUNTY COMMISSIONERS OKALOOSA COUNTY, FLORIDA SERVICE AREA: PHYSICAL ENVIRONMENT DEPARTMENT/PROGRAM: WATER & SEWER ENTERPRISE FUND/WATER OPERATIONS PROGRAM DESCRIPTION: This program
More informationSanitary Sewer Smoke Testing
Sanitary Sewer Smoke Testing Beginning March 31, 2014 The City of Brunswick will be conducting smoke testing on the City s sanitary sewer system beginning March 31, 2014. Smoke testing will occur over
More informationBEFORE THE PHILADELPHIA WATER, SEWER AND STORMWATER RATE BOARD DIRECT TESTIMONY OF STEPHEN J. FURTEK
BEFORE THE PHILADELPHIA WATER, SEWER AND STORMWATER RATE BOARD Re Application of the Philadelphia Water Department for Increased Rates and Related Charges Fiscal Years 2017-2018 DIRECT TESTIMONY OF STEPHEN
More informationAltoona Water Authority. Infrastructure Overview
Altoona Water Authority Infrastructure Overview Mission Statement As stewards of the community s water system, our mission is to provide a clean, safe, reliable water supply and to collect and treat wastewater
More informationCity of Auburn Summary of Capital Outlay by Fund and Department
General Fund ~ MidBiennium Budget Review ~ FY 04 City Council (none) $ Office of the City Manager $ 25,000 Judicial (none) Information Technology Information Technology Division Upgrade for intrusion detection
More informationLAKES REGION SANITARY DISTRICT COST REIMBURSEMENT PROGRAM FOR THE INSTALLATION OF OVERHEAD SEWERS OR BACKFLOW PREVENT DEVICES
PROGRAM REQUIREMENTS The District will provide funds to building owners who have or may experience sanitary sewer backups during periods of heavy rainfall for the installation of overhead sewers or backflow
More informationFY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation
644-10-569 Page 1 of 9 1 FOR CLEANING AND TELEVISING EXISTING SEWERS, AS SPECIFIED, ANY REQUIRED CLEANING, ANY LOCATION, ANY LENGTH OF SEWER, COMPLETE IN PLACE, FOR VARIOUS PIPE DIAMETERS. A. EXISTING
More informationWauwatosa Lateral Rehabilitation Pilot Project. CSWEA Annual Meeting Madison, WI May 15, 2013
Wauwatosa Lateral Rehabilitation Pilot Project CSWEA Annual Meeting Madison, WI May 15, 2013 Overview Background Objectives Work Completed Testing Evaluation Conclusions 2 Milwaukee Metropolitan Sewerage
More informationWEFTEC.06. Kent Von Aspern,* Collins Orton** *Carollo Engineers 2700 Ygnacio Valley Rd Suite 300 Walnut Creek, CA 94598
Lessons Learned from Large Diameter Sanitary Sewer Pipe Bursting Project: Conversion of Abandoned Gravity Sewer Main Into Upsized Sanitary Force Main South San Francisco, CA Kent Von Aspern,* Collins Orton**
More informationSECTION 02150 REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section 02250.
02150-1 of 6 SECTION 02150 REMOVAL OR ABANDONMENT OF EXISTING 02150.01 GENERAL A. Description Removal or abandonment of existing utilities and underground structures shall include, but not necessarily
More informationDrinking Water Sector - Damage Assessment Report
Drinking Water Sector - Damage Assessment Report The Division s Drinking Water Sector Damage Assessment Report (available on-line at the Division s Website http://www.state.nj.us/dep/watersupply ) and
More informationATTACHMENT 3: SPECIFICATION FOR SEWER CLEANING
ATTACHMENT 3: SPECIFICATION FOR SEWER CLEANING 1.0 General 1.1 The work covered by this section consists of providing all labor, equipment, material and supplies, insurance, accessories, tools, transportation,
More informationORDINANCE NO. 511 ORDINANCE ESTABLISHING A COST REIMBURSEMENT PROGRAM FOR THE INSTALLATION OF OVERHEAD SEWERS OR BACKFLOW PREVENTION DEVICES
ORDINANCE NO. 511 ORDINANCE ESTABLISHING A COST REIMBURSEMENT PROGRAM FOR THE INSTALLATION OF OVERHEAD SEWERS OR BACKFLOW PREVENTION DEVICES WHEREAS, Wheaton Sanitary District had a cost reimbursement
More informationCost Estimating Procedures for Raw Sewage Overflow Control Program
Raw Sewage Overflow Control Program April 23, 2004 Raw Sewage Overflow Control Program City of Indianapolis Department of Public Works Table of Contents Section Page 1.0 Introduction... 1 2.0 General Project
More informationMUNI OWNER S CHRONICLE OF REPLACING 35 MILES OF ASBESTOS CEMENT WATER MAIN UTILIZING PRE-CHLORINATED WATER MAIN BURSTING
MUNI OWNER S CHRONICLE OF REPLACING 35 MILES OF ASBESTOS CEMENT WATER MAIN UTILIZING PRE-CHLORINATED WATER MAIN BURSTING EDWARD ALAN AMBLER, PE BILL THOMAS, PHD, PE COLLINS ORTON AGENDA Introduction Asbestos
More informationPreserve the Tax-Exempt Status of Municipal Bonds
The, and its members, support the preservation of the existing tax-exempt status of municipal bonds. Specifically, FAC supports legislative provisions that: Uphold the tax-exempt status of municipal bonds.
More informationFacing The Challenges In Houston s Water System: Past, Present, and Future
Facing The Challenges In Houston s Water System: Past, Present, and Future Jun Chang, P.E. D.WRE Deputy Director Department of Public Works and Engineering Presented to HCEC February 17, 2012 Past Regulatory
More informationMEMORANDUM. Doug Monn, Public Works Director Jim App, City Manager. Matt Thompson, Wastewater Resources Manager. Date: January 24, 2011
MEMORANDUM To: From: Doug Monn, Public Works Director Jim App, City Manager Matt Thompson, Wastewater Resources Manager Date: January 24, 2011 Subject: Audit of 2010 Wastewater Collection Performance City
More informationSeptic System Owner s Manual
Septic System Owner s Manual Sponsored by: copyright 2013 No part of this publication may be reproduced without our consent. www.callbrownies.com Brownie s Septic and Plumbing has provided quality service
More informationSANITARY SEWER MASTER PLAN
SANITARY SEWER MASTER PLAN PREPARED FOR: VILLAGE OF GALENA, OHIO PREPARED BY: POGGEMEYER DESIGN GROUP, INC. 1168 NORTH MAIN STREET BOWLING GREEN, OHIO 43402 JOB NO. 3550-030 MARCH, 2006 TABLE OF CONTENTS
More informationSECTION III-06 Surfacing Page 1 Revised 3/2/10. See the DESIGN GUIDELINES in Section I-06 for requirements for cross slope of the roadway.
Page 1 Revised 3/2/10 See the DESIGN GUIDELINES in Section I-06 for requirements for cross slope of the roadway. For New/Reconstruction projects: The cross slope of the driving lanes range from 1.5% to
More informationTerry Biederman, PE- Director of Public Works Greg Gucwa, PE- Principal Johnson and Anderson Engineering
DON T JUST REHAB IT, RENEW IT! WATERFORD TOWNSHIP, MICHIGAN IMPROVEMENTS TO A 3.0 MGD SEWAGE PUMPING STATION Terry Biederman, PE- Director of Public Works Greg Gucwa, PE- Principal Johnson and Anderson
More informationPurpose and Approach. Introduction
City of Ann Arbor Sanitary Sewer Wet Weather Evaluation Project Best Practices Sub- Group of the Citizens Advisory Committee Examples of Wet Weather Improvements from Other Communities December 5, 2013
More informationThe Bond Release Process for New Subdivision Developments: An Overview for Homeowners Associations DRAFT 6-4-08. Revised 9-25-08
The Bond Release Process for New Subdivision Developments: An Overview for Homeowners Associations DRAFT 6-4-08. Revised 9-25-08 Fairfax County requires developers to post a performance bond if they are
More informationProtect Your Home From Flooding. A guide for Lethbridge Residents
Protect Your Home From Flooding A guide for Lethbridge Residents Every year, millions of litres of water flow into the City of Lethbridge s stormwater and wastewater collection systems from residential
More informationMokeWISE Program Scope of Work: Project 8b: Rehabilitation of Transmission Main
MokeWISE Program Scope of Work: April 2015 Abstract... 2 Background Information... 2 Calaveras Public Utility District... 2 Water Rights... 2 Water Supply... 2 Project Information... 3 Project Description...
More informationBulletin. Gerard D. Perry, Director of Accounts. DATE: August 2014. Sewer Rate Relief Fund FY2015
Massachusetts Department of Revenue Division of Local Services Amy A. Pitter, Commissioner Robert G. Nunes, Deputy Commissioner & Director of Municipal Affairs Bulletin TO: Mayors, City Managers, Selectmen,
More informationAffordable Asset Management Making Use of the Data You Have: An Owner s Perspective
Affordable Asset Management Making Use of the Data You Have: An Owner s Perspective An Owner Operator s Approach for Asset Management on a Budget Lane Longley, City of St. Petersburg Presented by the April
More informationSUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES TOXIC/HAZARDOUS MATERIAL TRANSFER FACILITY DESIGN GUIDELINES
SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES TOXIC/HAZARDOUS MATERIAL TRANSFER FACILITY DESIGN GUIDELINES 1.0 GENERAL 1.1 Article 12 of the Suffolk County Sanitary Code requires that toxic/hazardous material
More informationTestimony. Shaun LaLonde Agency Hearing Staff Eduardo Hernandez Applicant Witness
ISSUE #4 Is it feasible to connect the proposed Sewer District #27 to Sewer District #23 via a pump station and associated components, taking into account design, location, impacts (such as noise, odors,
More informationStandard Operating Guideline Maintenance Management System
Standard Operating Guideline (SOG) Title: MAINTENANCE MANAGEMENT SYSTEM District Name: Date Prepared: Date Revised: OBJECTIVE: A Maintenance Management System is an organized method of collecting documentation
More informationAmendment 1 Preliminary Engineering Report for the City of Salida
Amendment 1 Preliminary Engineering Report for the City of Salida Galleries Water Tank Rehabilitation Project February 11, 2010 Prepared by 1.0 Executive Summary The work of this Preliminary Engineering
More information