1 * English Manual for users * Video Data Recorder For the best production and the highest reliability, if you want an answer to your unexpected changes of values. 1

2 Data Acquisition system paperless recorder VideoDataRecorder Chapter 1 Introduction VideoDataRecorder is a software for analogic data acquisition with N x 8 channels, N x 32 channels, N x 64 channels (N is the page virtual number) in Windows O.S.; it is a virtual instrument which works as a chart recorder. Fig. 1 Graphs Fig. 2 Pannels Data are not recorded on paper but on PC. They can be saved and exported in any type of Office formats, from ASCII to Excel files, or Database or Web in order to be elaborated in Back process and/or Office. VideoDataRecorder can be integrated with any equipment able to communicate to a PC in serial or parallel port or through Ethernet, using modbus or current loop as fieldbus; it has been used a COM/DCOM STL ATL technology in order to obtain an instrument which will be adaptable, scaleable and integrable to other applications. Channels can be set and gathered in pages; every page can contain at most 32 channels. 2

3 The plotting of the traces occurs in real time and it is also possible to set and change it dynamically. Scale it is possible to define a scale for each channel; Colour it is possible to choose a colour for each trace; Width it is possible to choose the thickness of a trace; Grid it can be displayed horizontally or vertically, or both; grid density, colour and thickness can be changed; Mono-trace for each instrument (selected channel), it is also possible to display just one trace while the pens of the others channels are still visible and keep on moving in real time; Paper Speed it simulates different speeds of sliding paper; Sample time it allows data back up Recording the begin and the end of the recording start/stop It is also possible let the paper sliding back, while data are recording, in order to check the past traces immediately. Data are saved and stored and they can be marked out directly from the VideoDataRecorder or exported to any Office Database or Web instruments. In order to have a reliable and safe tele-control, VideoDataRecorder can also be controlled and it warns in case of anomaly throughout the GSM system. In the management of a process and its evolution, organized and saved data are an advantage because a paper chart recorder does not give exact numeric information but just a trend. Furthermore, data should be saved on an electronic support. 3

4 Software versions VideoDataRecorder 4 Channels VideoDataRecorder 8 Channels VideoDataRecorder 16 Channels VideoDataRecorder 32 Channels VideoDataRecorder 64 Channels VideoDataRecorder 128 Channels 4 Channels Basic Version 8 Channels Basic Version 16 Channels Basic Version 32 Channels Basic Version 64 Channels Basic Version 128 Channels Basic Version Optional Extensions Extension Math Formulas Create virtual channels based on mathematical formulas of real input: gauging the current and the voltage, it is also possible to plot also the power even if there is not an actual additional input. Application Modules Alarm management GSM alarm management Internet alarm management Bidirectional digital configuration Machine mapping/ production s recipes Formula setting pack Data encryption Alarm management is set a minimum and a maximum thresholds and it creates an alarm-log in the database. This module sends alarms via GSM. This module sends alarms via and allows the access to the recording from Web. Set up all the instruments parameters by remote access. This module creates configuration recipes for the instruments for different production. This module creates virtual channels as result of formulas among real variables of the process. For instance, acquiring current and voltage it is also possible to plot the power even if there is not an actual additional input. Data Integrity (Message marking MD5) in order to avoid any kind of data manipulation, with the use of proper controlling codes; in case of alteration, data are no more valid. Data Secrecy (Code encryption Procedure Triple DES) This module converts data in encryption data using an encryption algorithm. 4

5 Chapter 2 PC Configuration In the standard version, it is possible to set the data of communication between PC and the net or the fieldbus. From menu item Configuration/PC configuration Fig. 3 Main Menu Fig. 4 Serial Configuration PC Configuration Serial Port Change values Through the combo box Serial port; the serial port RS232 can be chosen where the net or the field bus is connected. Baud Rate Bit Stop Parity They are the parameters of the serial port which, for security, can be changed only when the Change values button is pressed. Refresh all the parameters OK Cancel Configuration values are updated when the button Refresh all the parameters is pressed. It saves the configuration on file It does not save the configuration on file. 5

6 Chapter 3 Technical Units Configuration It is possible to add or delete technical units of measure from the menu \Technical Units of Measure. Fig. 5 Main Menu If you need to add a new technical unit of measure, write its symbol or abbreviation in the box and click on the button Add and it will appear on the list. On the contrary, if you want to delete a technical unit of measure, select it from the list and then, click on the Delete button. If the deleted unit was the technical unit of an instrument, when the configuration will be launched again, the instrument will be configured with another technical unit (the last one in the list). Fig. 6 Technical Units 6

7 Chapter 4 Instruments Configuration From this menu, it is possible to set all the specifications of the channels that must be plotted, Each set channel is corresponded by a pen in the grid plotting. Parameters are divided into 3 sections: Channel configuration: For each channel, it must be indicated the actual instrument represented and the parameters of its display. Standard configuration: The typical specifications for the plotting: sample time, number of the plotting instruments, etc. Pages Configuration: Channels can be gathered in different pages. In each page, display parameters must be set: for instance, the colour of the background page or the grid. Fig. 7 Main Menu The channel configuration creates a correspondence between a pen and the input of an instrument, specifying the instrument serial number and the number of the input. The model of instrument must be chosen in order to let the PC recognize the sort of input has been selected (analogic or digital) and how many inputs are on the instrument. Furthermore, pen drawing characteristics can be selected for representing the channel in the graph. 7

8 Fig. 8 Configuration Panel Channel Configuration Channel Set the number of the channel. Serial Number Set the instrument serial number. Device Model Choose the model of the instrument. Input Choose the instrument number input. Type of input Set the analogic or digital input. Scale Begin Type in the value of Scale Begin. Scale End Type in the value of Scale End. Scale Current Scale. Page Choose the page where the instrument will be displayed in. Pen colour Choose the colour of the pen. Tag Description of the channel. Width Choose the thickness of the pen. There are two values of thickness: one is the double of the other. Update instrument Values Press it to update the instrument configuration: every time values are entered it is necessary to give a confirm. Display default Choose the display default: the graph or the panels Instrument / Formula The formula setting pack, you can create virtual channels (Formula) as the result of an algebraic formulas. It is very useful in case of experimental rating table values in polynomial formulas: the virtual channel behaves as a real channel. Repeat this configuration for each instrument/pen that can be set. 8

9 Standard Configurations concern the sampling time of the instruments which are plotting (minimum time: one second), the Number of Instruments to set, the Paper Speed, the number of samples that must be displayed on the chart recorder window, the Grid Density, a horizontal grid will display a density according to the number of recorded samples. Paper Speed= number of samples displayed on the screen Grid density= time unity number of sampling represented by the horizontal line 1 sampling time unity Fig. 9 Plotting page The option PA7 gives the possibility to begin and to end the recording through a digital input. The option Automatic sets the sampling time automatically to the lowest level, cutting out the lay out of the sampling time. Standard Configuration Sampling time Set the sampling time value in hour/minute/second. Instrument number Set the number of instruments which will be recorded on two pages; it can be different from that one of the instruments actually present. Paper Speed Number of recorded samples, displayed on the screen. Grid Density Horizontal grid will show a density gauged in number of samples. PA7 Start/Stop from digital input. Automatic Automatic sampling time. Save Common Press it to confirm set values. Values Page Configuration Page Choose a page. Type of page Set the page display with analogic or digital inputs. Background Colour Set the background colour of the chosen page. Grid Colour Set the grid colour of the chosen page. Save Pages Confirm pages configuration. Common buttons OK Quit Save and exit. Do not save changes and exit. 9

10 Chapter 5 Parameters Mapping Instruments parameters, as PID Set Point etc., can be modified from PC. Choose an instrument by typing the number of the box; the parameters current values will appear; they can be directly modified from the box. For negative values, the symbol - is recognized only if it is put before the value. Some parameters are disactivated for security. Fig. 10 Main Menu Fig. 11 Parameters Window Parameters Mapping Serial address Serial address of the instrument. OK Exit. 10

11 Chapter 6 GSM Configuration (This function is available only in the Extension GSM version) This section enables to configurate the communication with the GSM-interface, specifying which serial port should be used. Fig. 12 Main Menu Fig. 13 GSM Configuration GSM Interface Configuration Serial port Set the serial port with which the GSM interface is connected. Ok Confirm changes and exit. Cancel Exit without modifying the GSM configuration. 11

12 Chapter 7 Alarms Configuration (This function is available only in the Extension GSM version) The alarms configuration can be viewed from the menu-item Configuration/Alarms : Fig. 14 Main Menu Fig. 15 Alarms Configuration For each channel, on which you want to activate the alarms, two thresholds must be set: the lower and the upper one. These two thresholds delimit the area in which the channel works properly. When the system gauges a value which is outside the set thresholds, it sends an SMS alarm to each set addressee (see Telephone Number Configuration ) and saves a log in the database. Alarms Configuration Channel Pen-Number (or channel-number). Description Fill in the blank in order characterise the channel. Lower Threshold Lower threshold of the area in which the channel works properly. Uppen Threshold Upper threshold of the area in which the channel works properly. Alarm active If this option is set on Yes, the system will use the alarms for this particular pen/channel. 12

13 Chapter 8 Notice Configuration (This function is available only in the Extension GSM version) The Notice configuration can be viewed from the menu-item Configuration/Notice: Fig. 16 Main Menu Fig. 17 Notice Configuration When the control of the notice-transmission is activated, the system sends an SMS to each set addressee (see Telephone numbers configuration ). It occurs every determinate N hours, and indicates that the system is working. Notice Configuration Activate alarm transmission Notice Interval OK The alarm transmission can be activated/disconnected from this box. It specifies the interval of hours the notice has to be sent. Confirm the changes and exit. 13

14 Chapter 9 Telephone numbers configuration (This function is available only in the Extension GSM version) The telephone numbers-configuration can be viewed from the menu-item Configuration/Telephone numbers: Fig. 18 Main Menu Fig. 19 Telephone numbers Configuration In case of alarms or notices, the system sends an SMS to each set addressee. You are required to specify the addressee s telephone number and, if you would like, other information. Telephone numbers-configuration 14

15 Addressee Telephone number Add Modify Eliminate Esc Receiver s name. Telephone number to which the SMS should be send. Add a new addressee according to the information which has been set in the two boxes Addressee and Telephone number. Modify the selected addressee s data, setting as new the data which has been written in the two boxes Addressee and Telephone number Delete the selected addressee. Exit from Telephone Number Configuration. 15

16 Chapter 10 Language (if required) VideoDataRecorder is multilingual so it is possible to change dynamically the language in use: choose it with the mouse and confirm by pressing the button Ok. Fig. 20 Main Menu Fig. 21 Language Window 16

17 Chapter 11 Log File Records are exported in files which have an.vdr extension and are in excel format, in order to visualize them graphically. Fig. 22 Main Menu Select a recorded file Fig. 23 Log Archive Press Show to see recorded data 17

18 Fig. 24 Records Chart Fig. 25 Commands Historical Plotting ESC Quit. Print Print the current plotting. << Start Show all the samples at the plotting begin. <- Previous Show previous samples. -> Next Show next samples. End >> Show all the samples at the plotting end. At the outset, all the channels traces are displayed. It is possible to choose which channels must be displayed by the commands on the left side of the graphic. Some parameters of the displaying can be modified, too. 18

19 Fig. 26 Historical side commands Historical side commands Channel list It shows the descriptions of the all the channels. The graph shows the traces of the selected channels on the list. If you select some of them and then you click on the display button, only the selected channels will be displayed. Display Re-draw the graph according the new setting-out. Min Display the minimum value. Max Display the maximum value. Zoom Y Zoom on the Y-axis, plotting from Min to Max. Auto Y Zoom on the Y-axis, choosing automatically the values to display in order to see all the traces. Sample for page Number of samples which are plotting on the X-axis. Zoom X Zoom out on the X-axis, using the specified value in the box Sample for Page. 19

20 On the right side of the graph, there is a caption which shows, the description and the colour used in the graph for each displayed trace. Fig. 27 Caption If you click on the trace or on the caption, the samples will be displayed on the graph. Fig. 28 The samples on the graph 20

21 If you click on a sample, the sampling time and the value are displayed. Fig. 29 The sampling time and the value 21

22 Chapter 12 Recording Press Sample to begin recording Fig. 30 Recording Or from the menu item Fig. 31 Main Menu At first, a window will be shown and you will be required to digit the name of the file in which you would like to save your recording. The file will be saved inside the subdirectory Data. Fig. 32 File name of your recording The program will test the perfect working of all the instruments before starting recording. 22

23 Fig. 33 Net test-phase Then the recording will appear. It will start immediately if the PA7-control has not been activated. Otherwise, it will start working according to the digital input. Fig. 34 Recording 23

24 Fig. 35 Side Panel On the right side of the recording, you can see the information related to the channels which are on the current page. In this way, data of the 8 channels are shown at the same. If the page contains more than 8 channels, it will be possible to display the previous or the next 8 channels clicking on the buttons < and > on the top of the page. The red box displays the current channel (the one which is displayed in case of a monotrace visualization). For each channel, the following information are shown according this scheme: Channel number Last gauged value Pen color Scale Tag 24

25 Fig. 36 Upper Panel On the top of the page, general information about the recording are shown and it is also possible to control some parameters of the visualization: Superior Panel Esc The ESC button asks confirmation before ending the recording. Monotrace Monotrace Display allows the viewing of all the pens but only the trace of the current instrument, the Monotrace button becomes Multitrace and if it is pressed again, all the traces will appear again. Grid Open a window in order to change the grid settings. Changes are not irreversible. Page Change the displayed page. Recording Time of the begin of the recording. Scale Begin Begin of the scale of the current channel. Scale End End of the scale of the current channel. 0% - 100% / Real Shift from the real visualization from a x % visualization. In the real visualization, the interval between the values of the scale begin and the scale end is plotted. In the x % visualization, each channel is plotted according its values which are gauged as a ratio between the scale begin (0%) and end (100%). Refresh The begin and the end of the scale can be modified in order to display different areas from the ones which are set for the channels. Data file Recording file name. 25

26 Fig. 37 Grid Menu Grid Display Vertical Grid Horizontal Grid Paper Speed Grid Density Refresh Cancel Enable the Grid Vertical lines. Enable the Grid Horizontal lines. Change the paper speed dynamically. Change the density grid dynamically. Start up changes. Exit. 26

27 Fig. 38 Monotrace Recording Display 27

28 Fig. 39 Horizontal Grid 28

29 Fig. 40 Vertical Grid 29

30 Fig. 41 Paper Speed (according to the sampling time) 30

31 Chapter 13 Export From any data file, the command export takes out all the data concerning a certain period and it saves them in a new Excel file. Choose the archived file Fig. 42 Main Menu Fig. 43 Archive Menu Choose the begin date/time and the end date/time of the interval that must be exported in the new Excel file. Fig. 44 Export data 31

32 Data Export Date - Begin Tiem Begin Date End Time - End Export End Date of the begin of the interval that must be exported. Time of the begin of the interval that must be exported. Date of the end of the interval that must be exported. Time of the end of the interval that must be exported. Export data in excel/ascii format. Exit. For exporting data, click on Export button. Fig. 45 File name where you export data Choose the name of the file and click on OK. A file.asc will be created in the subdirectory Export. 32

33 Chapter 14 Excel Recordings (they are saved in the subdirectory Data with extension.vdr) and the exported files can be opened as an excel file. Fig. 46 Excel sheet 33

34 Chapter 15 Alarms-Log Consultation (This function is available only in the Extension GSM version) The alarms-log consultation can be viewed from the menu-item Log/Alarms: Fig. 47 Main Menu Fig. 48 Alarms log The system shows the list of all the recorded alarms entering in the alarm-log configuration. For each alarm, the system shows date, time, the description and the number of the involved channel when the anomaly has occurred. In the section Filters, you can set some particular conditions, in order to obtain a more accurate selection of the alarms you would like to visualize. Filters Alarms-log From To Channel Research Exit Select all the events occurred from the selected day. Select all the events occurred up to the selected day. Select all the events occurred on the selected channel. Show all the events selected according to the set filters. Exit the Alarms-Log Consultation. It is possible to obtain a report Alarms diary from the Alarms-Log where the list of all the occurred alarms, or just those occurred in a particular day, is displayed. 34

35 Alarms diary Date Diary Alarms diary Alarms diary date. If it is blank, all the occurred alarms will be displayed. Creation and display of the Alarms Diary (See). Fig. 49 Alarms Diary 35

36 Chapter 16 Client Video Data Recorder It is possible to launch a client from Start/Programs/VideoDataRecorder for: Plotting the recordings Exporting parts of the recording Consulting Log alarms Fig. 50 Main Page These functions are present in Video Data Recorder. The aim of this client is 1. to let the access to the recording while it is in progress, without interfering or slowing down it. 2. From other PC, it will be possible plotting the log files and exporting them in LAN Tcp/IP or Stand Alone Video Data Recorder where the recording is in progress Process P BUS LAN Stand Alone PC Video Data Recorder Client Fig. 51 Architecture The menus are the same to the Video Data Recorder s, so if you need more information, refer to the previous paragraphs. 36

37 Chapter 17 Internet/Intranet In order to access to Video Data Recorder through Internet/Intranet/LAN from another PC, the net must be TCP/IP, not Netbeui or IPX, otherwise it does not work. For interacting, you can find RTVNC Server and Client in the directory /support of the installation cd. If you need installing it, select and click on it. Fig. 52 RTVNC Once RTVNC Server and Client has been installed, from the command Start/Programs of Windows menu, this image will appear on the screen. Fig. 53 RTVNC Launch RTVNC Server and Client on PC where Video Data Recorder is installed. Fig. 54 RTVNC Server 37

38 Confirm default options and set out a password for security Install RTVNC Server and Client on the remote PC, the one from which you want to access in the PC where the Video Data Recorder is installed. Then launch Viewer and set Server IP address. If you want to know the IP address from MS-Command, launch the command IPCONFIG. Fig. 55 IPCONFIG In case of Internet connection, the IP address is the one assigned by ISP that you are connected with. Fig. 56 RTVNC Client 38

39 Chapter 18 Operative System: RAM HD Video Card Adp. System Requirement Windows 98 II or updated 64 Mb minimum / 128MB for the 64 channels version 3 Gb minimum SVGA minimum 800x600 bus PCI Recommended system requirement Operative System: Windows 2000 service pack or updated RAM 64 Mb minimum / 256MB for the 64 channels version HD 10 Gb minimum Video Card Adp. SVGA minimum 1024x768 AGP Options: Network card Modem TCP/IP protocol Internet connection access from LAN/Intranet access from Internet per RTVNC per accesso da Internet 39

40 Chapter 19 Installation notes Windows NT 4.0 In order to carry out the installation by Windows Installer, it is necessari to install Windows NT4 Service Pack 6. Windows XP In case of Windows XP versions which are not original, or have been copied and cracked or the serial numbers have been found on Internet, our system (as it usual happens in these cases) could have an unsteady behaviour. Piracy Epik reminds you that the use of this software and all the operative systems (all the Windows versions, even if they are not the original, or have been cracked or copied) implies civil and penal sanctions and makes the system unsteady. Compatibility with other software The VideoDataRecorder installation program has been developed using Microsoft tools and following Microsoft rules. Each version has been tested on different Windows versions and installations and it does not behave irregularly in case of Windows Operative System components or other software. In any case, a backup of your particular data is suggested before installing the software. INSTALLATION From the Cd, launch Setup.exe; in case of error messages on dll system installation as MFC42d.dll, click the button Quit and complete the installation: dll system has been already installed. The access to the DataBase requests the use of ADO 2.5, which is in the directory /support of the installation CD. If it is not there, install it. Fig. 57 ADO 2.5 The access to the DataBase requests also the use of DCOM98. If it is not in the system, install it. Fig. 58 DCOM98 If you are working with Windows NT or Windows 2000, you need to set up the following driver for the communication with the hardware (drivers are in the subfolder WinNT). 40

41 HARDEST KEY: Launch HARDESTset up Fig. 59 HARDEST Hardware Key Dirver EUTRON KEY: Fig. 60 EUTRON Hardware Key Driver Launch skeyadd to add the driver keyp.sys to the system, in order to verify the correct set up from Control Panel/System/Hardware/Device Manager. 41

42 Fig. 61 System 42

43 Choose from the menu View, the item menu Show hidden devices Fig. 62 Show hidden devices 43

44 From the item menu Non-Plug and Play Drivers, check if KEYP is present. Fig. 63 KEYP 44

45 Issued on: Automazione Industriale ITALY November 2001 Pg.61 Automazione Oggi ITALY Giugno 2002 Pg.130 Der Elktro-Und Gebäudetechniker GERMANY 14/2002 Pg.69 Automazione Industriale ITALY September 2001 Pg.80 45

46 Index INTRODUCTION... 2 PC CONFIGURATION... 5 TECHNICAL UNITS CONFIGURATION... 6 INSTRUMENTS CONFIGURATION... 7 PARAMETERS MAPPING GSM CONFIGURATION ALARMS CONFIGURATION NOTICE CONFIGURATION TELEPHONE NUMBERS CONFIGURATION LANGUAGE LOG FILE RECORDING EXPORT EXCEL ALARMS-LOG CONSULTATION CLIENT VIDEO DATA RECORDER INTERNET/INTRANET SYSTEM REQUIREMENT INSTALLATION NOTES INDEX

Device configurator DRC200

Device configurator DRC200 Operating manual 42/49-27 EN Engineer IT Device configurator DRC200 R&C Process Data Management Software Impressum Device configurator DRC200 Operating manual Document No. 42/49-27 EN Date of issue: 11.02

More information

Short Manual Intellect v.4.7.6 SP2 module Unipos Contents:

Short Manual Intellect v.4.7.6 SP2 module Unipos Contents: Short Manual Intellect v.4.7.6 SP2 module Unipos Contents: 1. Software Installation... 2 2. Hardware Configuration... 12 3. System Dispatching... 14 3.1. Create dispatching objects... 14 3.2. Graphical

More information

User Manual WatchPower

User Manual WatchPower User Manual WatchPower Management Software for Inverter Table of Contents 1. WatchPower Overview... 1 1.1. Introduction... 1 1.2. Features... 1 2. WatchPower Install and Uninstall... 1 2.1. System Requirement...

More information

User Guide Win7Zilla

User Guide Win7Zilla User Guide Win7Zilla Table of contents Section 1: Installation... 3 1.1 System Requirements... 3 1.2 Software Installation... 3 1.3 Uninstalling Win7Zilla software... 3 Section 2: Navigation... 4 2.1 Main

More information

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems ViewPower User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. ViewPower Overview... 2 1.1. Introduction...2 1.2. Structure...2 1.3. Applications...2 1.4. Features...2

More information

SA-9600 Surface Area Software Manual

SA-9600 Surface Area Software Manual SA-9600 Surface Area Software Manual Version 4.0 Introduction The operation and data Presentation of the SA-9600 Surface Area analyzer is performed using a Microsoft Windows based software package. The

More information

Config software for D2 systems USER S MANUAL

Config software for D2 systems USER S MANUAL DT-CONFIG SOFTWARE Config software for D2 systems USER S MANUAL CONTENTS 1. Introductions ------------------------------------------------------------------- 3 2. System Requirement and Connection ----------------------------------------

More information

User s Manual. Management Software for Inverter

User s Manual. Management Software for Inverter WatchPower User s Manual Management Software for Inverter Table of Contents 1. WatchPower Overview... 2 1.1. Introduction... 2 1.2. Features... 2 2. WatchPower Install and Uninstall... 2 2.1. System Requirement...

More information

ACS CLIENT SOFTWARE USER MANUAL

ACS CLIENT SOFTWARE USER MANUAL ACS CLIENT SOFTWARE USER MANUAL 1 ACS USER GUIDE 1.1 System Requirement Recommended System Requirement OS CPU VGA RAM HDD WindowXP, Vista Pentium 4, 2Ghz 1024*768, 64MB 24bit color graphic card 1GB 20MB

More information

PowerLogic ION Enterprise 5.6

PowerLogic ION Enterprise 5.6 PowerLogic ION Enterprise 5.6 Power Management Software User Guide April 2007 Notices This section describes the symbols used in this guide. Danger This alerts you to things that may cause serious injury

More information

StrikeRisk v6.0 IEC/EN 62305-2 Risk Management Software Getting Started

StrikeRisk v6.0 IEC/EN 62305-2 Risk Management Software Getting Started StrikeRisk v6.0 IEC/EN 62305-2 Risk Management Software Getting Started Contents StrikeRisk v6.0 Introduction 1/1 1 Installing StrikeRisk System requirements Installing StrikeRisk Installation troubleshooting

More information

Licensed Functionality: Remote Monitoring

Licensed Functionality: Remote Monitoring Appendices 473 Chapter 24 Licensed Functionality: Remote Monitoring Remote Monitoring functionality is available through an optional license available with AcqKnowledge 4.2 or above. The license must be

More information

Manual. Sealer Monitor Software. Version 0.10.7

Manual. Sealer Monitor Software. Version 0.10.7 Manual Sealer Monitor Software Version 0.10.7 Contents 1 Introduction & symbols 1 2 Installation 2 2.1 Requirements 2 2.2 Installation process 2 3 Menu & Tooblar 5 3.1 File menu 5 3.2 Print menu 6 3.3

More information

Power Log PC Application Software

Power Log PC Application Software Power Log PC Application Software Users Manual May 2007 Rev. 1, 5/08 2007-2008 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks

More information

Monitoring Network DMN

Monitoring Network DMN Monitoring Network DMN User Manual Table of contents Table of contents... 2 1. Product features and capabilities... 3 2. System requirements... 5 3. Getting started with the software... 5 3-1 Installation...

More information

Overview of ServerView Windows Agent This chapter explains overview of ServerView Windows Agent, and system requirements.

Overview of ServerView Windows Agent This chapter explains overview of ServerView Windows Agent, and system requirements. ServerView User s Guide (For Windows Agent) Areas Covered - Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview of ServerView

More information

DVS Net (Integration)

DVS Net (Integration) DVS Net (Integration) Installation and User s Guide Ver 11.10.x Digital Video Security System Digital Video Recorder www.tuniss.com PLEASE CALL TUNISS COMPUTER AT: 650-401-6138 FOR ANY QUASTIONS REGARDING

More information

PowerLogic ION Enterprise 6.0

PowerLogic ION Enterprise 6.0 70002-0298-00 06/2009 PowerLogic ION Enterprise 6.0 Power management software User guide Notices This section describes the symbols used in this guide. Danger This alerts you to things that may cause

More information

User Manual V1.0. Remote Software

User Manual V1.0. Remote Software User Manual V1.0 Notice: The information in this manual was current when published. The manufacturer reserves the right to revise and improve its products. All specifications are therefore subject to change

More information

1 Minimum system requirements

1 Minimum system requirements Metrohm AG CH-9101 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 info@metrohm.com www.metrohm.com Installation MagIC Net 2.x 1 Minimum system requirements Operating system RAM Memory

More information

Kokii BatteryDAQ. BMS Software Manual. Battery Analyzer Battery DAS

Kokii BatteryDAQ. BMS Software Manual. Battery Analyzer Battery DAS Kokii BatteryDAQ BMS Battery Analyzer Battery DAS Updated: October 2008 Caution: High Voltage Exists on Battery Power and Sampling Connectors! Please refer to device installation and operation manual for

More information

GE Security. FHSD Monitor / Web Server user manual

GE Security. FHSD Monitor / Web Server user manual GE Security FHSD Monitor / Web Server user manual version 1-0 / november 2004 http://www.geindustrial.com/ge-interlogix/emea 2004 GE Interlogix B.V.. All rights reserved. GE Interlogix B.V. grants the

More information

Real Time Monitor. A Real-Time Windows Operator Interface. DDE Compliant. (for remote data display)

Real Time Monitor. A Real-Time Windows Operator Interface. DDE Compliant. (for remote data display) Real Time Monitor A Real-Time Windows Operator Interface DDE Compliant (for remote data display) TABLE OF CONTENTS 1. INTRODUCTION...1 1.1 INSTALLATION...2 1.2 FIRST START UP - DDE CONFIGURE...2 1.3 AUTO-STARTUP...2

More information

User s Manual. Management Software for ATS

User s Manual. Management Software for ATS ATS Monitor User s Manual Management Software for ATS Table of Contents 1. ATS Monitor Overview... 2 2. ATS Monitor Install and Uninstall... 2 2.1. System Requirement... 2 2.2. Software Install... 2 2.3.

More information

Quick Start Using DASYLab with your Measurement Computing USB device

Quick Start Using DASYLab with your Measurement Computing USB device Quick Start Using DASYLab with your Measurement Computing USB device Thank you for purchasing a USB data acquisition device from Measurement Computing Corporation (MCC). This Quick Start document contains

More information

Network FAX Driver. Operation Guide

Network FAX Driver. Operation Guide Network FAX Driver Operation Guide About this Operation Guide This Operation Guide explains the settings for the Network FAX driver as well as the procedures that are required in order to use the Network

More information

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide Version 2.1, 4/2010 Disclaimer While every effort has been made to ensure that the information in this guide is accurate

More information

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012 Quick Note 32 Using Digi RealPort with a Digi TransPort Router UK Support September 2012 1 Contents 1 Introduction... 3 1.1 Outline... 3 1.2 Assumptions... 3 1.3 Version... 3 2 Configuration & scenario...

More information

User s Manual. Management Software for Uninterruptible Power Supply Systems

User s Manual. Management Software for Uninterruptible Power Supply Systems PowerShield NetGuard User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. NetGuard Overview...2 1.1. Introduction...2 1.2. Structure...2 1.3. Applications...3

More information

User s Guide for version 5 Page

User s Guide for version 5 Page Network Management Interface Catalog VPi 32.15E For use with these ATS products: 7000 & 4000 Series (Group 5 Controller) Series 300 (Group 1 Controller), and 940, 962, 436, 434, 447, 448 (Group 6A/7A Control

More information

STORAGE SYSTEM DATALOGGER DATABASE

STORAGE SYSTEM DATALOGGER DATABASE STORAGE SYSTEM DATALOGGER DATABASE Database based storage system for data acquisition systems, dataloggers and transmitters Instruction Manual Introduction This storage system is database based system

More information

1. Specification Installation Using Net software DiViS Login Setup Accessing DiViS Net

1. Specification Installation Using Net software DiViS Login Setup Accessing DiViS Net DiViS Net (Integration) Installation and User s Guide Ver 12.10.1 Digital Video Security System Digital Video Recorder www.divisdvr.com Chance-i USA Corp. *All contents of this document may change without

More information

10 Thomas, Irvine, CA 92618 USA Tel: (949) 465-0900 Fax: (949) 465-0905 Toll Free: (800) 23 FUTEK

10 Thomas, Irvine, CA 92618 USA Tel: (949) 465-0900 Fax: (949) 465-0905 Toll Free: (800) 23 FUTEK Table of Contents Software Overview... - 4 - Product Key... - 5 - Model Selection... - 6 - Device Selection... - 7 - Menu... - 8 - File... - 8 - Edit... - 8 - View... - 8 - Format... - 8 - Help... - 9

More information

Manual. Danfoss Central Station Communications Software Version 3

Manual. Danfoss Central Station Communications Software Version 3 Manual Danfoss Central Station Communications Software Version 3 RS.8A.Q1.02 1-2001 Contents Introduction 4 System Overview 4 Minimum and Recommended Hardware Requirements 4 Using the Keyboard to Select

More information

ViewPower User Manual

ViewPower User Manual ViewPower User Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. ViewPower Overview... 1 1.1. Introduction... 1 1.2. Structure... 1 1.3. Applications... 1 1.4. Features...

More information

QIAsymphony Management Console User Manual

QIAsymphony Management Console User Manual April 2012 QIAsymphony Management Console User Manual For use with software version 4.0 Sample & Assay Technologies Trademarks QIAGEN, QIAsymphony, Rotor-Gene (QIAGEN Group). InstallShield (Informer Technologies,

More information

Instruction manual. testo easyheat Configuration and Analysis software

Instruction manual. testo easyheat Configuration and Analysis software Instruction manual testo easyheat Configuration and Analysis software en 2 General Information General Information This documentation includes important information about the features and application of

More information

SMS (Server Management Software) Digital Video Recorder. User s Manual

SMS (Server Management Software) Digital Video Recorder. User s Manual SMS (Server Management Software) Digital Video Recorder User s Manual Contents 1 - Introduction 2 1.1 About this manual 2 1.2 Configuration 2 1.3 SMS Functions 2 1.4 Product Information 2 1.5 System Requirements

More information

Korosi Monitoring System (KMS) Software Manual

Korosi Monitoring System (KMS) Software Manual PT. KOROSI SPECINDO Corrosion Monitoring System Eng. Doc. No.: KS-MNL-KMS Korosi Monitoring System (KMS) Software Manual Revision Date Prepared Approved Description 0 23/05/2008 ES JH Issued for approval

More information

INTELLECT TM Software Package

INTELLECT TM Software Package AxxonSoft INTELLECT TM Software Package Quick Start Guide Version 1.0.0 Moscow 2010 1 Contents CONTENTS... 2 1 INTRODUCTION... 3 1.1 Document purpose... 3 1.2 Purpose of the Intellect software package...

More information

Access Control Software Manual

Access Control Software Manual CONTENTS 1. Function overview...1 2. Installation environment...2 3. Concept description...3 4. Installation and Uninstallation...4 4.1 Installation...4 4.2 Uninstallation...10 5. Function instroduction...11

More information

@ptitude Observer. Installation Manual. Part No. 32170700 Revision G

@ptitude Observer. Installation Manual. Part No. 32170700 Revision G Part No. 32170700 Revision G Installation Manual Copyright 2012 by SKF Reliability Systems All rights reserved. Aurorum 30, 977 75 Lulea Sweden Telephone: +46 (0) 31 337 10 00, Fax: +46 (0) 920 134 40

More information

OPTAC Fleet Viewer. Instruction Manual

OPTAC Fleet Viewer. Instruction Manual OPTAC Fleet Viewer Instruction Manual Stoneridge Limited Claverhouse Industrial Park Dundee DD4 9UB Help-line Telephone Number: 0870 887 9256 E-Mail: optac@stoneridge.com Document version 3.0 Part Number:

More information

Diamond II v2.3 Service Pack 4 Installation Manual

Diamond II v2.3 Service Pack 4 Installation Manual Diamond II v2.3 Service Pack 4 Installation Manual P/N 460987001B ISS 26APR11 Copyright Disclaimer Trademarks and patents Intended use Software license agreement FCC compliance Certification and compliance

More information

IP-Pro (Virtual IP Protocol Independent Version) User Instructions

IP-Pro (Virtual IP Protocol Independent Version) User Instructions IP-Pro (Virtual IP Protocol Independent Version) User Instructions - Table of Contents - 1. IP Pro introduction 2. IP Pro installation 3. IP Pro setup 4. Virtual IP function check 5. Virtual IP changes

More information

Imaging Computing Server User Guide

Imaging Computing Server User Guide Imaging Computing Server User Guide PerkinElmer, Viscount Centre II, University of Warwick Science Park, Millburn Hill Road, Coventry, CV4 7HS T +44 (0) 24 7669 2229 F +44 (0) 24 7669 0091 E cellularimaging@perkinelmer.com

More information

JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP

JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP AZI P/N 700-0042-B Last update May 2009 USER MANUAL JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP May 2009 ARIZONA INSTRUMENT LLC 3375 N Delaware Street Chandler,

More information

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. www.apm-solutions.com Version 3.0

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. www.apm-solutions.com Version 3.0 3DLevelScanner II Different Ways of Connecting to 3DLevelScanner II A.P.M Automation Solutions LTD. www.apm-solutions.com Version 3.0 2 Different Ways of Connecting to 3DLevelScanner II Version 3.0 Table

More information

OPTAC Fleet Viewer. Instruction Manual

OPTAC Fleet Viewer. Instruction Manual OPTAC Fleet Viewer Instruction Manual Stoneridge Limited Claverhouse Industrial Park Dundee DD4 9UB Help-line Telephone Number: 0870 887 9256 E-Mail: optac@stoneridge.com Document version 4.0 Part Number:

More information

DCS110 CATVisor COMMANDER

DCS110 CATVisor COMMANDER Broadband Cable Networks April 13, 2006 1(5) DCS110 CATVisor COMMANDER Introduction CATVisor Commander is the standalone software tool for configuring, adjusting and monitoring Teleste Headend and HFC

More information

Software Operations Manual

Software Operations Manual Software Operations Manual Version 5.0 BinMaster 7201 North 98th Street Lincoln, NE 68507 Phone: 402-434-9102 / Fax: 402-434-9133 info@binmaster.com - www.binmaster.com System Requirements PC with 1GHz

More information

EasyMP Monitor Operation Guide Ver.4.40

EasyMP Monitor Operation Guide Ver.4.40 EasyMP Monitor Operation Guide Ver.4.40 2 Notations Used in This Guide The following table shows the symbols used in this manual, along with descriptions of what they mean. Caution q s Indicates procedures

More information

Installation Instruction STATISTICA Enterprise Small Business

Installation Instruction STATISTICA Enterprise Small Business Installation Instruction STATISTICA Enterprise Small Business Notes: ❶ The installation of STATISTICA Enterprise Small Business entails two parts: a) a server installation, and b) workstation installations

More information

Prestige 314 Read Me First

Prestige 314 Read Me First Prestige 314 Read Me First Console WAN 10M PORT Prestige Rear Panel Connections CONNECTION Use an RS-232 console cable. Use the cable that came with your broadband modem. LAN 10/100M Port Number COMPUTER

More information

CashFlow Programming Module CPM

CashFlow Programming Module CPM CashFlow Programming Module CPM Installation & User Guide GB REV G4 08/08/2006 Table of Content Table of Content... 2 CashFlow Programming Module (CPM)... 4 What is a CPM?... 4 CPM Identification... 4

More information

Central Management System

Central Management System Central Management System Software Installation Guide Ver. 1.5.0.101115.001 ... ii System Introduction... 3 Client/Server Architecture...3 System Requirements... 4 System Setup...4 Multiple Monitor Configuration...5

More information

Handheld LPC Utility Software for Windows. Operation Manual

Handheld LPC Utility Software for Windows. Operation Manual Handheld LPC Utility Software for Windows MODEL S388-70 Operation Manual Read this manual carefully and understand the warnings described in this manual before operating the product. Keep this manual handy

More information

Table of contents TABLE OF CONTENTS... 2 ABOUT THIS MANUAL... 3 IMPORTANT NOTES... 3 PICO LOGGING APPLICATION... 5 ABOUT THE PICO LOGGING PC

Table of contents TABLE OF CONTENTS... 2 ABOUT THIS MANUAL... 3 IMPORTANT NOTES... 3 PICO LOGGING APPLICATION... 5 ABOUT THE PICO LOGGING PC 1 Table of contents TABLE OF CONTENTS... 2 ABOUT THIS MANUAL... 3 IMPORTANT NOTES... 3 PICO LOGGING APPLICATION... 5 ABOUT THE PICO LOGGING PC APPLICATION... 5 WHERE TO GET A HOLD OF THE PICO LOGGING APPLICATION...

More information

National Fire Incident Reporting System (NFIRS 5.0) Configuration Tool User's Guide

National Fire Incident Reporting System (NFIRS 5.0) Configuration Tool User's Guide National Fire Incident Reporting System (NFIRS 5.0) Configuration Tool User's Guide NFIRS 5.0 Software Version 5.6 1/7/2009 Department of Homeland Security Federal Emergency Management Agency United States

More information

SNMP-NET Client Shutdown Management Software for Windows 2000/XP/2003 User s Manual

SNMP-NET Client Shutdown Management Software for Windows 2000/XP/2003 User s Manual Client Management Software for Windows 2000/XP/2003 User s Manual PN: 340000285 Introduction Client is designed to provide the user the ability to take proactive steps to protect their equipment from power

More information

3.5 EXTERNAL NETWORK HDD. User s Manual

3.5 EXTERNAL NETWORK HDD. User s Manual 3.5 EXTERNAL NETWORK HDD User s Manual Table of Content Before You Use Key Features H/W Installation Illustration of Product LED Definition NETWORK HDD Assembly Setup the Network HDD Home Disk Utility

More information

IsItUp Quick Start Manual

IsItUp Quick Start Manual IsItUp - When you need to know the status of your network Taro Software Inc. Website: www.tarosoft.com Telephone: 703-405-4697 Postal address: 8829 110th Lane, Seminole Fl, 33772 Electronic mail: Contact1@tarosoft.com

More information

PMS. Energy management and monitoring software. Installation and operation instructions. BMR trading Horní lán 17 77900 Olomouc Czech Republic

PMS. Energy management and monitoring software. Installation and operation instructions. BMR trading Horní lán 17 77900 Olomouc Czech Republic PMS Energy management and monitoring software Installation and operation instructions version 1.5 77900 Olomouc 1 Content 1. PMS introduction...3 1.1. PMS structure...3 1.2. System requirements...3 2.

More information

AXIS Camera Station Quick Installation Guide

AXIS Camera Station Quick Installation Guide AXIS Camera Station Quick Installation Guide Copyright Axis Communications AB April 2005 Rev. 3.5 Part Number 23997 1 Table of Contents Regulatory Information.................................. 3 AXIS Camera

More information

C-more Remote Access, Data Log, FTP File Transfer, and Email Tutorial

C-more Remote Access, Data Log, FTP File Transfer, and Email Tutorial C-more Remote Access, Data Log, FTP File Transfer, and Email Tutorial P a g e 2 Introduction: This script will walk you through the basic process of setting up the remote access, data logging, FTP file

More information

Mobile Video Analysis Software User Guide. Version 2.0.8

Mobile Video Analysis Software User Guide. Version 2.0.8 User Guide Version 2.0.8 Content 1. Introduction......1 1.1 Software Overview... 1 1.2 Documentation Overview... 1 1.3 Application Range... 1 1.4 System Requirements... 1 2. Getting Started... 3 2.1 Main

More information

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher OPERATION MANUAL MV-410RGB Layout Editor Version 2.1- higher Table of Contents 1. Setup... 1 1-1. Overview... 1 1-2. System Requirements... 1 1-3. Operation Flow... 1 1-4. Installing MV-410RGB Layout

More information

WINDOWS PHONE CMS for WINDOWS PHONE phones user's manual

WINDOWS PHONE CMS for WINDOWS PHONE phones user's manual WINDOWS PHONE CMS for WINDOWS PHONE phones user's manual User s manual version 0.1 (January 2013) This manual applied to program version 3.0.0.xxx Table of contents The table of contents is empty because

More information

Remote Backup Software User Manual V 2.0

Remote Backup Software User Manual V 2.0 Remote Backup Software User Manual V 2.0 Table of Contents Chapter 1 Welcome to Remote Backup Software... 2 1.1 Overview... 2 1.2 Computer Disposition Request... 2 1.3 Convention... 2 Chapter 2 Installing

More information

UPS Monitoring Software. User manual Borri Power Guardian

UPS Monitoring Software. User manual Borri Power Guardian UPS Monitoring Software User manual Borri Power Guardian For Microsoft Windows 8 Microsoft Windows Server 2012 Microsoft Windows 7 Microsoft Windows Server 2008 R2 Microsoft Windows VISTA Microsoft Windows

More information

Creating client-server setup with multiple clients

Creating client-server setup with multiple clients Creating client-server setup with multiple clients Coffalyser.Net uses a SQL client server database model to store all project/experiment- related data. The client-server model has one main application

More information

ComTool Tool for managing parametric controllers

ComTool Tool for managing parametric controllers ComTool Tool for managing parametric controllers User manual 2 IMPORTANT WARNINGS BEFORE INSTALLING OR HANDLING THE DEVICE PLEASE CAREFULLY READ AND FOLLOW THE INSTRUCTIONS DESCRIBED IN THIS MANUAL. The

More information

EasyMP Monitor Operation Guide Ver.4.53

EasyMP Monitor Operation Guide Ver.4.53 EasyMP Monitor Operation Guide Ver.4.53 2 Notations Used in This Guide The following table shows the symbols used in this manual, along with descriptions of what they mean. q s Indicates additional information

More information

Meridian 1 Meridian 1 Attendant PC LAN Interface Installation Guide

Meridian 1 Meridian 1 Attendant PC LAN Interface Installation Guide Meridian 1 Meridian 1 Attendant PC LAN Interface Installation Guide Document Number: P0874391 Document Release: Standard 1.00 Date: November 1997 Year Publish FCC TM 1997 All rights reserved Printed in

More information

NetClient software user manual

NetClient software user manual NetClient software user manual 1-1. General information Net Client is an application which provides users not only viewing and controling remote DVRs, but also receiving realtime event data or alarm signals

More information

Iridium Extreme TM Satellite Phone. Data Services Manual

Iridium Extreme TM Satellite Phone. Data Services Manual Iridium Extreme TM Satellite Phone Data Services Manual Table of Contents 1 OVERVIEW... 1 2 HOW IT WORKS... 1 3 BEFORE INSTALLING... 2 4 USB DRIVER INSTALLATION... 3 5 MODEM INSTALLATION AND CONFIGURATION...

More information

Vantage RADIUS 50. Quick Start Guide Version 1.0 3/2005

Vantage RADIUS 50. Quick Start Guide Version 1.0 3/2005 Vantage RADIUS 50 Quick Start Guide Version 1.0 3/2005 1 Introducing Vantage RADIUS 50 The Vantage RADIUS (Remote Authentication Dial-In User Service) 50 (referred to in this guide as Vantage RADIUS)

More information

Installing the Microsoft Network Driver Interface

Installing the Microsoft Network Driver Interface Installing the Microsoft Network Driver Interface Overview This guide explains how to install the PictureTel Live200 Microsoft Network Driver Interface (NDIS) software you have downloaded from PictureTel's

More information

CMS-DH CENTRAL MANAGEMENT SOFTWARE

CMS-DH CENTRAL MANAGEMENT SOFTWARE CMS-DH CENTRAL MANAGEMENT SOFTWARE CMS-DH is a central management software that allows you to view and manage up to 300 DH200 series DVRs. System Requirements Your system must meet the system requirements

More information

S m a r t M a s t e B T E C O R P O R A T I O N USER MANUAL

S m a r t M a s t e B T E C O R P O R A T I O N USER MANUAL S m a r t M a s t e rtm 2014 B T E C O R P O R A T I O N USER MANUAL S m a r t M a s t e r T M 2 0 1 4 U s e r M a n u a l P a g e 1 o f 2 3 Contents Contents...1 Introduction...2 Audience...2 SmartMaster

More information

AdminToys Suite. Installation & Setup Guide

AdminToys Suite. Installation & Setup Guide AdminToys Suite Installation & Setup Guide Copyright 2008-2009 Lovelysoft. All Rights Reserved. Information in this document is subject to change without prior notice. Certain names of program products

More information

Temperature Controller Support Software

Temperature Controller Support Software Temperature Controller Support Software CX-Thermo Ver.4.0 Online Help Contents Chapter 1 Introduction 1.1 What is CX-Thermo? 1.2 Compatible Device Models and Computers 1.3 Hardware Setups 1.4 Basic Use

More information

Engineering and service software For KNX and LPB plants

Engineering and service software For KNX and LPB plants 5 649 Engineering and service software For KNX and LPB plants As of V9.00 ACS790 The engineering and service software ACS790 is for KNX and LPB plants equipped with the appropriate bus devices. The software

More information

Professional Surveillance System User s Manual

Professional Surveillance System User s Manual Professional Surveillance System User s Manual Version 4.06 Table of Contents 1 OVERVIEW AND ENVIRONMENT... 1 1.1 Overview...1 1.2 Environment...1 2 INSTALLATION AND UPGRADE... 2 2.1 Installation...2 2.2

More information

Keystone 600N5 SERVER and STAND-ALONE INSTALLATION INSTRUCTIONS

Keystone 600N5 SERVER and STAND-ALONE INSTALLATION INSTRUCTIONS The following instructions are required for installation of Best Access System s Keystone 600N5 (KS600N) network key control software for the server side. Please see the system requirements on the Keystone

More information

TICO-EN. TiXML-Console TICO. User Manual V1.4.0.8

TICO-EN. TiXML-Console TICO. User Manual V1.4.0.8 TICO-EN TiXML-Console TICO User Manual V1.4.0.8 2008 Tixi.Com GmbH, Berlin Publication close: September 2008, v.1.4.0.8 This manual is protected by copyright. Any further sale is prohibited without the

More information

COMMUNICATION SERVER 1000 COMMUNICATION SERVER 1000 TELEPHONY MANAGER

COMMUNICATION SERVER 1000 COMMUNICATION SERVER 1000 TELEPHONY MANAGER COMMUNICATION SERVER 1000 COMMUNICATION SERVER 1000 TELEPHONY MANAGER TECHNICAL SPECIFICATIONS Communication Server 1000 Telephony Manager 3.2 Communication Server 1000 Telephony Manager 3.0 Communication

More information

HP LaserJet MFP Analog Fax Accessory 300 Send Fax Driver Guide

HP LaserJet MFP Analog Fax Accessory 300 Send Fax Driver Guide HP LaserJet MFP Analog Fax Accessory 300 Send Fax Driver Guide Copyright and License 2008 Copyright Hewlett-Packard Development Company, L.P. Reproduction, adaptation, or translation without prior written

More information

Monitor Wall 4.0. Installation and Operating Manual

Monitor Wall 4.0. Installation and Operating Manual Monitor Wall 4.0 en Installation and Operating Manual Monitor Wall 4.0 Table of Contents en 3 Table of Contents 1 Introduction 4 1.1 About this Manual 4 1.2 Conventions in this Manual 4 1.3 Minimum Installation

More information

Inventory Tracking Software Operations Manual

Inventory Tracking Software Operations Manual Version 4.1 Inventory Tracking Software Operations Manual Shipping Address: 7201 N. 98th St., Lincoln, NE 68507 Mailing Address: P.O. Box 29709, Lincoln, NE 68529 Toll Free: 800-278-4241 System Requirements

More information

Figure 1: RotemNet Main Screen

Figure 1: RotemNet Main Screen 1 REMOTE CONTROLLER ACCESS This paper summarizes the installation and configuration procedures needed to enable accessing your Communicator and controllers via the Internet. The information contained in

More information

Ovation Operator Workstation for Microsoft Windows Operating System Data Sheet

Ovation Operator Workstation for Microsoft Windows Operating System Data Sheet Ovation Operator Workstation for Microsoft Windows Operating System Features Delivers full multi-tasking operation Accesses up to 200,000 dynamic points Secure standard operating desktop environment Intuitive

More information

Computer Requirements

Computer Requirements Installing Pro64 Network Manager It is recommended that you quit all running Windows applications before starting the Aviom Pro64 Network Manager installation process. Check the Aviom website (www.aviom.com)

More information

Orbit PCI Mk 2 Network Card. User Manual. Part No. 502566 Issue 4

Orbit PCI Mk 2 Network Card. User Manual. Part No. 502566 Issue 4 Orbit PCI Mk 2 Network Card User Manual Part No. 502566 Issue 4 Information in this document is subject to change without notice. Companies, names and data used in examples herein are fictitious unless

More information

USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks

USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St. Neihu,

More information

CMS Central Monitoring System

CMS Central Monitoring System General In This Section CMS for Windows CMS Hardware CMS Functional Spec Relational Database Monitoring Interface Communication Network CMS Central Monitoring System General CMS Central Monitoring System

More information

HiPath 3000/5000 HiPath TAPI 120 V2.0. Installation and Configuration

HiPath 3000/5000 HiPath TAPI 120 V2.0. Installation and Configuration HiPath 3000/5000 HiPath TAPI 120 V2.0 Nur für den internen Gebrauch tapi_120_entoc.fm Content Content 0 1 Introduction.......................................................... 1-1 1.1 What is HiPath

More information

Guest PC. for Mac OS X. User Guide. Version 1.6. Copyright 1996-2005 Lismore Software Systems, Ltd. All rights reserved.

Guest PC. for Mac OS X. User Guide. Version 1.6. Copyright 1996-2005 Lismore Software Systems, Ltd. All rights reserved. Guest PC for Mac OS X Version 1.6 User Guide Copyright 1996-2005 Lismore Software Systems, Ltd. All rights reserved. Table of Contents About Guest PC... 1 About your Virtual Computer... 1 Creating a Virtual

More information