HEERHUGOWAARD. T: +31 (0) Technical information

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "HEERHUGOWAARD. T: +31 (0)72 57 66 700. WWW.TOTALHYDRAULICSBV.COM. Technical information"

Transcription

1 HY 005 Type Oil flow Capacity Weight Voltage Frequency Current Power Fan Ø Air flow Noise Level l/1' l kg V Hz A W mm m 3 /h db(a) HY , /60 0,13/0,11 30/ ,8 0,05 0,04 0,03 0,02 0,7 0,6 0,5 0,3 0,2 0,1 0, C Oil : ISO Multiply for : 0,7 0,9 1 1, Oesse Oliekoelers - 101

2 HY 005 Voltage Current Power Type Oil flow Capacity Weight Fan Ø Air flow Noise Level l/1' l kg V A W mm m 3 /h db(a) HY , ,6 7, HY , ,3 7, ,05 0,04 0,07 0,06 0,05 0,04 0,03 0,02 0,03 0,02 0,01 0, Oil Flow (l/1 ) Oil: ISO 40 C Multiply for: 0,7 0,9 1 1, Oesse Oliekoelers - 102

3 HY 010 Voltage Frequency Type Oil flow Capacity Weight Current Power Fan Ø Air flow Noise Level l/1' l kg V Hz A W mm m 3 /h db(a) HY , /60 0, HY , /400 50/60 0, ,10 0,09 0,08 0,07 0,06 0,05 0,04 0,03 0,02 0, ,0 0,8 0,6 0, Oil (l/1 ) Flow - Oil - ISO 40 C Multiply for : 0,7 0,9 1 1, Oesse Oliekoelers - 103

4 HY 010 Voltage Current Type Oil flow Capacity Weight Power Fan Ø Air flow Noise Level l/1' l kg V A W mm m 3 /h db(a) HY ,8 4,8 12 6,3 75, HY ,8 4,8 24 3,3 79, ,10 0,09 0,08 0,07 0,06 0,05 0,04 0,03 0,02 0, ,0 0,8 0,6 0, Oil: ISO 40 C Multiply for : 0,7 0,9 1 1, Oesse Oliekoelers - 104

5 HY 014 Frequency Current Type Oil flow Capacity Weight Voltage Power Fan Ø Air flow Noise Level l/1' l kg V Hz A W mm m 3 /h db(a) HY ,3 5, /60 0,27/0,33 62/ HY ,3 5,7 230/400 50/60 1,28/1,1 66/ ,16 0,14 0,12 0,10 0,08 0,06 0,04 0, ,8 1,6 1,4 1,2 1,0 0,8 0,6 0, Oil: ISO 40 C Multiply for: 0,7 0,9 1 1, Oesse Oliekoelers - 105

6 HY 014 Voltage Current Type Oil flow Capacity Weight Power Fan Ø Air flow Noise Level l/1' l kg V A W mm m 3 /h db(a) HY ,3 4,7 12 8,2 98, HY ,3 4,7 24 2,6 62, ,16 0,14 0,12 0,10 0,08 0,06 0,04 0, ,8 1,6 1,4 1,2 1,0 0,8 0,6 0, Oil : ISO 40 C Multiply for : 0,7 0,9 1 1, Oesse Oliekoelers - 106

7 HY 016 Frequency Current Type Oil flow Capacity Weight Voltage Power Fan Ø Air flow Noise Level l/1' l kg V Hz A W mm m 3 /h db(a) HY ,6 6, /60 0,27/0,33 62/ HY ,6 6,6 230/400 50/60 1,28/1,1 66/ ,18 0,16 0,14 0,12 0,10 0,08 0,06 0,04 0, ,9 0,8 0,7 0,6 0,5 0,3 0,2 0, Oil: ISO 40 C Multiply for : 0,7 0,9 1 1, Oesse Oliekoelers - 107

8 HY 016 Voltage Current Type Oil flow Capacity Weight Power Fan Ø Air flow Noise Level l/1' l kg V A W mm m 3 /h db(a) HY , ,6 91, HY , , ,175 0,150 0,125 0,100 0,075 0,050 0, ,9 0,8 0,7 0,6 0,5 0,3 0,2 0, Oil : ISO 40 C Multiply for : 0,7 0,9 1 1, Oesse Oliekoelers - 108

9 HY 018 Frequency Current Type Oil flow Capacity Weight Voltage Power Fan Ø Air flow Noise Level l/1' l kg V Hz A W mm m 3 /h db(a) HY ,3 7, /60 0,27/0,33 62/ HY ,3 7,7 230/400 50/60 1,28/1,1 66/ ,24 0,16 0,12 0,08 0, ,9 0,8 0,7 0,6 0,5 0,3 0,2 0, Oil : ISO 40 C Multiply for : 0,7 0,9 1 1, Oesse Oliekoelers - 109

10 HY 018 Voltage Current Type Oil flow Capacity Weight Power Fan Ø Air flow Noise Level l/1' l kg V A W mm m 3 /h db(a) HY , ,6 91, HY , , ,175 0,150 0,125 0,100 0,075 0,050 0, ,7 0,6 0,5 0,3 0,2 0, Oil : ISO 40 C Multiply for: 0,7 0,9 1 1, Oesse Oliekoelers - 110

11 HY 020 Voltage Frequency Type Oil flow Capacity Weight Current Power Fan Ø Air flow Noise Level l/1' l kg V Hz A W mm m 3 /h db(a) HY ,7 9, /60 3/0,52 100/ HY ,7 9,3 230/400 50/60 0,39/0,56 90/ ,24 0,16 0,12 0,08 0,8 0,7 0,6 0,5 0,3 0,2 0,1 0, Oil: ISO 40 C Multiply for: 0,7 0,9 1 1, Oesse Oliekoelers - 111

12 HY " G 1" G T Type Oil flow Capacity Weight Voltage Current Power Fan Ø Air flow Noise Level l/1' l kg V A W mm m 3 /h db(a) HY ,7 8,5 12 9, HY ,7 8,5 24 4, ,35 0,30 0,25 0,15 0,10 1,0 0,8 0,6 0,2 0, Oil : ISO 40 C Multiply for : 0,7 0,9 1 1, Oesse Oliekoelers - 112

13 HY 024 Frequency Current Type Oil flow Capacity Weight Voltage Power Fan Ø Air flow Noise Level l/1' l kg V Hz A W mm m 3 /h db(a) HY ,7 11, /60 3/0,52 100/ HY ,7 11,4 230/400 50/60 0,39/0,56 90/ ,36 0,32 0,28 0,24 0,16 0,12 0,08 0, ,9 0,8 0,7 0,6 0,5 0,3 0,2 0, Oil : ISO 40 C Multiply for : 0,7 0,9 1 1, Oesse Oliekoelers - 113

14 HY 024 Voltage Current Type Oil flow Capacity Weight Power Fan Ø Air flow Noise Level l/1' l kg V A W mm m 3 /h db(a) HY , , HY , , ,35 0,30 0,25 0,15 1,2 1,0 0,8 0,6 0,2 0,10 0, Oil : ISO 40 C Multiply for : 0,7 0,9 1 1, Oesse Oliekoelers - 114

15 HY 036 Frequency Current Type Oil flow Capacity Weight Voltage Power Fan Ø Air flow Noise Level l/1' l kg V Hz A W mm m 3 /h db(a) HY ,6 12, /60 0,95/1,17 220/ HY ,6 12,6 230/400 50/60 1/1,2 250/ ,35 0,30 0,25 0,15 0,10 0,7 0,6 0,5 0,3 0,2 0,1 0, Oil: ISO 40 C Multiply for : 0,7 0,9 1 1, Oesse Oliekoelers - 115

16 HY 036 Voltage Current Type Oil flow Capacity Weight Power Fan Ø Air flow Noise Level l/1' l kg V A W mm m 3 /h db(a) HY ,6 11, , HY ,6 11,5 24 7, ,55 0, ,35 0,30 0,25 0,15 0,10 0, ,7 0,6 0,5 0,3 0,2 0, Oil : ISO 40 C Multiply for: 0,7 0,9 1 1, Oesse Oliekoelers - 116

17 HY 037 Voltage Frequency Current Type Oil flow Capacity Weight Power Fan Ø Air flow Noise Level l/1' l kg V Hz A W mm m 3 /h db(a) HY ,2 18, /60 0,52/0,74 120/ HY ,2 18,4 230/400 50/60 0,56/0,78 130/ , ,375 0,300 0,225 2,5 2,0 1,5 1,0 0,5 0,150 0, Oil : ISO 40 C Multiply for: 0,7 0,9 1 1, Oesse Oliekoelers - 117

18 HY 037 Voltage Current Type Oil flow Capacity Weight Power Fan Ø Air flow Noise Level l/1' l kg V A W mm m 3 /h db(a) HY ,2 17, HY ,2 17, ,0 0,50 0 0,30 1,6 1,2 0,8 0, Oil : ISO 40 C Multiply for : 0,7 0,9 1 1, Oesse Oliekoelers - 118

19 HY 038 Voltage Frequency Current Type Oil flow Capacity Weight Power Fan Ø Air flow Noise Level l/1' l kg V Hz A W mm m 3 /h db(a) HY ,8 19, /60 0,95/1,17 220/ HY ,8 19,3 230/400 50/60 1/1,2 250/ ,50 0 0,30 1,2 1,0 0,8 0,6 0,2 0, Oil : ISO 40 C Multiply for : 0,7 0,9 1 1, Oesse Oliekoelers - 119

20 HY 038 Voltage Current Type Oil flow Capacity Weight Power Fan Ø Air flow Noise Level l/1' l kg V A W mm m 3 /h db(a) HY ,8 18, , HY ,8 18,5 24 7, ,55 0, ,35 0,30 0,25 0,15 0,10 0, ,0 0,8 0,6 0,2 0, Oil : ISO 40 C Multiply for: 0,7 0,9 1 1, Oesse Oliekoelers - 120

21 HY 055 Voltage Frequency Type Oil flow Capacity Weight Current Power Fan Ø Air flow Noise Level l/1' l kg V Hz A W mm m 3 /h db(a) HY ,3 20, /60 0,52/0,74 120/ HY ,3 20,3 230/400 50/60 0,56/0,78 130/ ,70 0,50 0 0,30 1,6 1,4 1,2 1,0 0,8 0,6 0,2 0, Oil : ISO 40 C Multiply for: 0,7 0,9 1 1, Oesse Oliekoelers - 121

22 HY 055 Voltage Current Type Oil flow Capacity Weight Power Fan Ø Air flow Noise Level l/1' l kg V A W mm m 3 /h db(a) HY ,3 19, HY ,3 19, ,70 0,50 0 0,30 1,6 1,4 1,2 1,0 0,8 0,6 0,2 0, Oil: ISO 40 C Multiply for: 0,7 0,9 1 1, Oesse Oliekoelers - 122

23 HY 057 Frequency Current Type Oil flow Capacity Weight Voltage Power Fan Ø Air flow Noise Level l/1' l kg V Hz A W mm m 3 /h db(a) HY ,7 22, /60 0,69/0,95 160/ HY ,7 22,4 230/400 50/60 0,56/0,78 130/ ,70 0,50 0 0,30 1,4 1,2 1,0 0,8 0,6 0,2 0, Oil : ISO 40 C Multiply for: 0,7 0,9 1 1, Oesse Oliekoelers - 123

24 HY 057 Voltage Current Type Oil flow Capacity Weight Power Fan Ø Air flow Noise Level l/1' l kg V A W mm m 3 /h db(a) HY ,7 20, HY ,7 20, ,70 0,50 0 0,30 1,4 1,2 1,0 0,8 0,6 0,2 0, Oil - : ISO 40 C Multiply for: 0,7 0,9 1 1, Oesse Oliekoelers - 124

25 HY Volt Voltage Frequency Type Oil flow Capacity Weight Current Power Fan Ø Air flow Noise Level l/1' l kg V Hz A W mm m 3 /h db(a) HY , /400 50/60 0,56/0,78 130/ ,80 0,70 0,50 0 0,30 0, ,2 1,0 0,8 0,6 0,2 0, Oil : ISO 40 C Multiply for : 0,7 0,9 1 1, Oesse Oliekoelers - 125

26 HY 098 Voltage Current Type Oil flow Capacity Weight Power Fan Ø Air flow Noise Level l/1' l kg V A W mm m 3 /h db(a) HY , HY , ,90 0,80 0,70 0,50 0 0,30 1,2 1,0 0,8 0,6 0,2 0, Oil : ISO 40 C Multiply for: 0,7 0,9 1 1, Oesse Oliekoelers - 126

27 HY 105 Voltage Frequency Type Oil flow Capacity Weight Current Power Fan Ø Air flow Noise Level l/1' l kg V Hz A W mm m 3 /h db(a) HY , /400 50/60 0,55/0,72 305/ ,90 0,80 0,70 0,50 0 0,30 0, ,4 1,2 1,0 0,8 0,6 0,2 0, Oil : ISO 40 C Multiply for: 0,7 0,9 1 1, Oesse Oliekoelers - 127

28 HY 105 Voltage Current Type Oil flow Capacity Weight Power Fan Ø Air flow Noise Level l/1' l kg V A W mm m 3 /h db(a) HY , x 9,2 2 x x x HY , x 4,5 2 x x x ,90 0,80 0,70 0,50 0 0,30 0, ,8 1,6 1,4 1,2 1,0 0,8 0,6 0, Oil: ISO 40 C Multiply for : 0,7 0,9 1 1, Oesse Oliekoelers - 128

29 HY Volt Volt Frequency Current Type Oil flow Capacity Weight Voltage Power Fan Ø Air flow Noise Level l/1' l kg V Hz A W mm m 3 /h db(a) HY ,5 33, /60 0,69/0,95 160/ HY ,5 33,5 230/400 50/60 0,56/0,78 130/ ,90 0,80 0,70 0,50 0 0,30 0, ,4 1,2 1,0 0,8 0,6 0, Oil : ISO 40 C Multiply for: 0,7 0,9 1 1, Oesse Oliekoelers - 129

30 HY 115 Voltage Current Type Oil flow Capacity Weight Power Fan Ø Air flow Noise Level l/1' l kg V A W mm m 3 /h db(a) HY , HY , ,90 0,80 0,70 0,50 0 0,30 0, ,2 1,0 0,8 0,6 0,2 0, Oil: ISO 40 C Multiply for: 0,7 0,9 1 1, Oesse Oliekoelers - 130

31 HY 130 Frequency Current Type Oil flow Capacity Weight Voltage Power Fan Ø Air flow Noise Level l/1' l kg V Hz A W mm m 3 /h db(a) 230/ ,46/1, HY / ,3/1, ,60 1,40 1,20 1,00 0, ,6 1,4 1,2 1,0 0,8 0,6 0, Oil: ISO 40 C Multiply for: 0,7 0,9 1 1, Oesse Oliekoelers - 131

32 HY 130 Type Oil flow Capacity Weight Displacement rpm Motor flow Power Fan Ø Air flow Noise Level l/1' l kg cm 3 /g g/1' l/1 W mm m 3 /h db(a) HY , HY ,60 1,40 1,20 1,00 0, ,6 1,4 1,2 1,0 0,8 0,6 0, Oil : ISO 40 C Multiply for: 0,7 0,9 1 1, Oesse Oliekoelers - 132

33 HY 140 Frequency Current Type Oil flow Capacity Weight Voltage Power Fan Ø Air flow Noise Level l/1' l kg V Hz A W mm m 3 /h db(a) 230/ ,46/1, HY / ,3/1, ,80 1,60 1,40 1,20 1,00 0,80 2,0 1,6 1,2 0, Oil : ISO 40 C Multiply for : 0,7 0,9 1 1, Oesse Oliekoelers - 133

34 HY 140 Type Oil flow Capacity Weight Displacement rpm Motor flow Power Fan Ø Air flow Noise Level l/1' l kg cm 3 /g g/1' l/1 W mm m 3 /h db(a) HY , HY ,40 2,10 1,80 1,50 1,20 0,90 2,0 1,6 1,2 0,8 0, Oil (l/1 ) Flow Oil: ISO 40 C Multiply for : 0,7 0,9 1 1, Oesse Oliekoelers - 134

35 HY Volt Volt Type Oil flow Capacity Weight Voltage Frequency Current Power Fan Ø Air flow Noise Level l/1' l kg V Hz A W mm m 3 /h db(a) HY / ,8/1, / ,8/1, ,70 2,40 2,10 1,80 1,50 1,20 0,90 2,0 1,6 1,2 0,8 0, Oil : ISO 40 C Multiply for: 0,7 0,9 1 1, Oesse Oliekoelers - 135

36 HY 160 Type Oil flow Capacity Weight Displacement rpm Motor flow Power Fan Ø Air flow Noise Level l/1' l kg cm 3 /g g/1' l/1 W mm m 3 /h db(a) HY , HY ,20 2,80 2,40 2,00 1,60 1,20 2,0 1,6 1,2 0,8 0, Oil : ISO 40 C Multiply for: 0,7 0,9 1 1, Oesse Oliekoelers - 136

37 HY 215 Voltage Frequency Type Oil flow Capacity Weight Current Power Fan Ø Air flow Noise Level l/1' l kg V Hz A W mm m 3 /h db(a) 230/ ,4/1,4 HY ,7 28 0, / ,1/1,2 0,80 0,70 0,50 0 0,30 1,00 0,80 0 0, Oil : ISO 40 C Multiply for: 0,7 0,9 1 1, Oesse Oliekoelers - 137

38 HY 215 Voltage Current Type Oil flow Capacity Weight Power Fan Ø Air flow Noise Level l/1' l kg V A W mm m 3 /h db(a) HY , HY , ,70 0,50 0 0,30 1,00 0,80 0 0, Oil (l/1 ) Flow Oil : ISO 40 C Multiply for: 0,7 0,9 1 1, Oesse Oliekoelers - 138

39 HY 220 Voltage Frequency Current Type Oil flow Capacity Weight Power Fan Ø Air flow Noise Level l/1' l kg V Hz A W mm m 3 /h db(a) 230/ ,2-1,8 HY / ,8-1,6 1,05 0,90 0,75 5 0,30 0,8 0,7 0,6 0,5 0,3 0,2 0,1 0, Oil : ISO 40 C Multiply for : 0,7 0,9 1 1, Oesse Oliekoelers - 139

40 HY 220 Voltage Current Type Oil flow Capacity Weight Power Fan Ø Air flow Noise Leve l/1' l kg V db(a) A W mm m 3 /h HY X 9,2 2 X X X HY X 4,5 2 X X X ,05 0,90 0,75 5 0,30 0,80 0,70 0,50 0 0,30 0,10 0, Oil : ISO 40 C Multiply for: 0,7 0,9 1 1, Oesse Oliekoelers - 140

41 HY 220 Type Oil flow Capacity Weight Displacement rpm Motor flow Power Fan Ø Air flow Noise Level l/1' l kg cm 3 /g g/1' l/1 W mm m 3 /h db(a) HY HY ,20 1,05 0,90 0,75 5 0,30 0, ,20 1,00 0, Oil: ISO 40 C Multiply for : 0,7 0,9 1 1, Oesse Oliekoelers - 141

42 HY 225 Voltage Frequency Current Type Oil flow Capacity Weight Power Fan Ø Air flow Noise Level l/1' l kg V Hz A W mm m 3 /h db(a) 230/ ,8-2,7 HY / ,2-2,4 1,60 1,40 1,20 1,00 0, ,40 1,20 1,00 0, Oil : ISO 40 C Multiply for : 0,7 0,9 1 1, Oesse Oliekoelers - 142

43 HY 225 Voltage Current Type Oil flow Capacity Weight Power Fan Ø Air flow Noise Level l/1' l kg V A W mm m 3 /h db(a) HY X 17,6 2 X X X HY X 7,6 2 X X X ,40 1,20 1,00 0,80 0 1,40 1,20 1,00 0, Oil : ISO 40 C Multiply for : 0,7 0,9 1 1, Oesse Oliekoelers - 143

44 HY 225 Type Oil flow Capacity Weight Displacement rpm Motor flow Power Fan Ø Air flow Noise Level l/1' l kg cm 3 /g g/1' l/1 W mm m 3 /h db(a) HY , HY ,60 1,40 1,20 1,00 0, ,40 1,20 1,00 0, Oil : ISO 40 C Multiply for: 0,7 0,9 1 1, Oesse Oliekoelers - 144

45 HY 230 Voltage Frequency Current Type Oil flow Capacity Weight Power Fan Ø Air flow Noise Level l/1' l kg V Hz A W mm m 3 /h db(a) 230/ ,8-2,7 HY / ,2-2,4 2,00 1,75 1,50 1,25 1,00 0,75 0,50 0, ,00 1,75 1,50 1,25 1,00 0,75 0,50 0, Oil: ISO 40 C Multiply for : 0,7 0,9 1 1, Oesse Oliekoelers - 145

46 HY 230 Type Oil flow Capacity Weight Displacement rpm Motor flow Power Fan Ø Air flow Noise Level l/1' l kg cm 3 /g g/1' l/1 W mm m 3 /h db(a) HY , HY ,00 1,75 1,50 1,25 1,00 0,75 0,50 0, ,00 1,75 1,50 1,25 1,00 0,75 0,50 0, Oil: ISO 40 C Multiply for: 0,7 0,9 1 1, Oesse Oliekoelers - 146

47 HY 235 Voltage Frequency Type Oil flow Capacity Weight Current Power Fan Ø Air flow Noise Level l/1' l kg V Hz A W mm m 3 /h db(a) 230/ ,8-2,7 HY / ,2-2,4 2,40 2,10 1,80 1,50 1,20 0,90 2,50 2,00 1,50 1,00 0,50 0, Oil : ISO 40 C Multiply for : 0,7 0,9 1 1, Oesse Oliekoelers - 147

48 HY 235 Type Oil flow Capacity Weight Displacement rpm Motor flow Power Fan Ø Air flow Noise Level l/1' l kg cm 3 /g g/1' l/1 W mm m 3 /h db(a) HY , HY ,00 2,70 2,40 2,10 1,80 1,50 1,20 0,90 0, ,50 2,00 1,50 1,00 0, Oil : ISO 40 C Multiply for: 0,7 0,9 1 1, Oesse Oliekoelers - 148

49 statement ISO 9001 PED CONFORMITY CERTIFICATION According to the Law - D.L. 25th February 2000, n. 93 OESSE s.r.l. DECLARE Under their own responsability that the heat exchanger identified by the following data: COD ART LN SN MODEL DATE TEMP RANGE MAX PRES TEST PRES Is IN CONFORMITY with all the legislative provisions in force which apply to the directive 97/23 Equipement Directive accepted in Italy with the law d.l. 93/2000. Pressure OESSE General Manager Francesco Scandolo 3220 Oesse Oliekoelers - 149

50 HY statement ISO 9001 PED The manufacturer Declairs that the unit mentioned as From the serie For the kind of circuit Produced for Oesse Srl via Maestri del Lavoro 81/ PORCIA (PN) - Italy Heat Exchangers HY OIL European market At these design conditions OIL SIDE Pressure 24 < - bar Volume 49 < - l Fluid (Type 2) is placed on SEP area according to PED 97/23 art 3 regulamentation as vessel and it doesn't require any further assurance system nor CE mark Place and date of issue Oesse general manager Porcia (PN) 01/07/2004 Francesco Scandolo Results PS 1000 PS=1000 PS=500 PS=V= C I PS=10 C II 1 PS=0,5 0,1 0, V(L) Fluid: Type2 Pressure :24 Volume (I): 49 Inspection Category: SEP Notes:NO QUALITY ASSURANCE SYSTEM Design and Manifacture to Sound Engineering Practice No Notified Body Involvment. Item must NOT be CE marked 3220 Oesse Oliekoelers - 150

51 HM Voltage Current Type Oil flow Capacity Weight Power Fan Ø Air flow Noise Level l/1' l kg V A W mm m 3 /h db(a) HM ,28 0,24 0,16 0,12 0,08 0, ,6 0,5 0,3 0,2 0, Oil : ISO 40 C Multiply for: 0,7 0,9 1 1, Oesse Oliekoelers - 151

52 HW 1001_A Inspectable Water-Oil Heat Exchangers Versione industriale Industrial type Uscita olio Sa = Scarico acqua Wd = Water discharge So = Scarico olio Od = Oil discharge Components - DESCRIPTION MANTELLO - SHELL TUBI - TUBES PIASTRA TUBIERA - TUBES SHEET TESTATE - HEADS DIAFRAMMI - BAFFLES GUARNIZIONI - SEAL - MATERIALS Al CuDHP Br G25 OT52 NBR (Viton) Technical and Dimensions Informations Surface Oil flow Water flow Oil contents Water contents Weight Type Perfor. with oil (kw) Dimension s =60 C - H20=20 C C (mm) m2 l/1' l/1' l l Kg A (mm) B (mm) ØD (BSP) ØE (BSP) 1,7-7 0, ,5 0,7 5, /4 3/4 HW10011A 6 HW10012A 2-8,5 0, ,6 0,8 6, /4 3/4 HW10013A 2,5-12,5 0, ,9 0,9 6, /4 3/4 HW10014A 3,5-17,5 0, ,3 1, /4 3/4 HW10015A 4,5-24 0, ,6 9, /4 3/4 HW10016A 5,5-32 1, ,9 2, /4 3/4 30 Olio- Oil: ISO 40 C 16A 2,0 Oil side 16A 1,5 15A 25 15A 1,0 14A 20 14A 0,5 13A 12A 11A Temperature correction factor T* C Multiplying for F 0,6 0,8 1 1,2 1,4 * T = Oil inlet temp. - Water inlet temp. 13A 12A 11A 0,12 0,08 0, Portata olio / factor Oil: ISO 40 C Multiplying for 0,7 0,9 1 1,1 1,5 2 Water side Water flow correction factor l/ Water Flow Multiplying for F 0,2 0,6 0,8 1 Water Flow (l/1 ) 16A 15A 14A 13A 12A 11A 3220 Oesse Oliekoelers - 152

53 HW 1001_B Inspectable Water-Oil Heat Exchangers Versione marina Marine type Sa = Scarico acqua Wd = Water discharge * = + Anodo Zn + Anode Zn So = Scarico olio Od = Oil discharge Components - DESCRIPTION - SHELL - TUBES - TUBES SHEET - HEADS - BAFFLES - SEAL - MATERIALS Al Cu-Ni Br Br OT52 NBR (Viton) Technical and Dimensions Informations Surface Oil flow Water flow Oil contents Water contents Weight Type Perfor. with oil (kw) Dimension s =60 C - H20=20 C C (mm) m2 l/1' l/1' l l Kg A (mm) B (mm) ØD (BSP) ØE (BSP) 1,7-7 0, ,5 0, /4 3/4 HW10011B 9 6 HW10012B 2-8,5 0, ,6 0,8 6, /4 3/4 HW10013B 2,5-12,5 0, ,9 0, /4 3/4 HW10014B 3,5-17,5 0, ,3 1,2 8, /4 3/4 HW10015B 4,5-24 0, ,6 9, /4 3/4 HW10016B 5,5-32 1, ,9 2,1 12, /4 3/4 Oil side 30 Oil: ISO 40 C 16B 2,0 16A 1,5 15A 25 15B 1,0 14A 20 14B 0,5 13A 12A 11A 15 13B 10 12B 11B Temperature correction factor C T* Multiplying for F 0,6 0,8 1 1,2 1,4 * T = Water inlet temp. Water flow correction factor l/ Water Flow Multiplying for F 0,2 0,6 0,8 1 0,12 0,08 0, factor Oil: ISO 40 C Multiplying for 0,7 0,9 1 1,1 1,5 2 Water side B 15B 14B 13B 12B 11B Water Flow (l/1 ) 3220 Oesse Oliekoelers - 153

54 HW 1002_B Inspectable Water-Oil Heat Exchangers Versione marina Marine type Sa = Scarico acqua Wd = Water discharge So = Scarico olio Od = Oil discharge Components - DESCRIPTION - SHELL - TUBES - TUBES SHEET - HEADS - BAFFLES - SEAL - MATERIALS Al Cu-Ni Br Br OT52 NBR (Viton) Technical and Dimensions Informations Surface Oil flow Water flow Oil contents Water contents Weight Type Perfor. with oil(kw) Dimension s =60 C - H20=20 C C (mm) m2 l/1' l/1' l l Kg A (mm) B (mm) ØD (BSP) ØE (BSP) 5,5-27 1, ,9 2,4 15, /2max. 3/4 HW10021B HW10022B , ,5 2,7 17, /2max. 3/4 HW10023B , ,2 3,1 18, /2max. 3/4 HW10024B 7,5-43 1, ,1 3,6 20, /2max. 3/4 HW10025B , ,2 4,2 23, /2max. 3/4 HW10026B , ,4 4,9 25, /2max. 3/4 HW10027B , ,9 5,7 29, /2max. 3/4 HW10028B , ,8 6,7 33, /2max. 3/4 Oil side Oil: ISO 40 C 28B 27B 26B 25B 24B 23B 2,5 2,0 1,5 1,0 0,5 28B 27B 26B 25B 24B 23B 22B 21B Temperature correction factor T* C Multiplying for F 0,6 0,8 1 1,2 1,4 * T = Oil inlet temp. - Water inlet temp. 22B 21B factor Oil: ISO 40 C Multiplying for 0,7 0,9 1 1,1 1,5 2 Water side 28B 0,30 27B 26B 0,25 25B 24B 23B 22B 21B 0,15 0,10 0,05 - Water flow correction factor l/ Portata Acqua - Water Flow Multiplying for F 0,2 0,6 0,8 1 Water Flow (l/1 ) 3220 Oesse Oliekoelers - 154

55 HW 1003_A Inspectable Water-Oil Heat Exchangers Industrial type Sa = Scarico acqua Wd = Water discharge So = Scarico olio Od = Oil discharge Components - DESCRIPTION - SHELL - TUBES - TUBES SHEET - HEADS - BAFFLES - SEAL - MATERIALS Al CuDHP Br G25 OT52 NBR (Viton) Technical and Dimensions Informations Surface Oil flow Water flow Oil contents Water contents Weight Type Perfor. with oil(kw) Dimension s =60 C - H 20=20 C C (mm) m2 l/1' l/1' l l Kg A (mm) B (mm) ØD (BSP) ØE (BSP) , ,2 5,9 32,6 926, max. 1 1/2max. HW10031A HW10032A , ,5 6,9 36,3 1087, max. 1 1/2max. HW10033A , ,8 1279, max. 1 1/2max. HW10034A , ,8 9,3 46,2 1511, max. 1 1/2max. HW10035A , ,6 1789, max. 1 1/2max. HW10036A , ,6 12,9 60,3 2122, max. 1 1/2max. Oil side Oil: ISO 40 C 36A 3,5 36A A 34A 33A 32A 3,0 2,5 2,0 1,5 1,0 35A 34A 33A 32A 31A 80 31A 0, factor Oil: ISO 40 C Multiplying for 0,7 0,9 1 1,1 1, Water side Temperature correction factor T* C Multiplying for F 0,6 0,8 1 1,2 1,4 * T = Oil inlet temp. - Water inlet temp. Water flow correction factor - Water Flow l/ ,35 0,30 0,25 0,15 0,10 0, A 35A 34A 33A 32A 31A - Multiplying for F 0,2 0,6 0,8 1 Water Flow (l/1 ) 3220 Oesse Oliekoelers - 155

56 HW 1003_B Inspectable Water-Oil Heat Exchangers Marine type Sa = Scarico acqua Wd = Water discharge So = Scarico olio Od = Oil discharge Components - DESCRIPTION SHELL TUBES TUBES SHEET HEADS BAFFLES SEAL - MATERIALS Al Cu-Ni Br Br OT52 NBR (Viton) Technical and Dimensions Informations Surface Oil flow Water flow Oil contents Water contents Weight Type Perfor. with oil(kw) Dimension s =60 C - H20=20 C C (mm) m2 l/1' l/1' l l Kg A (mm) B (mm) ØD (BSP) ØE (BSP) , ,2 5,9 33, max. 1 1/2max. HW10031B HW10032B , ,5 6,9 36, max. 1 1/2max. HW10033B , , max. 1 1/2max. HW10034B , ,8 9,3 46, max. 1 1/2max. HW10035B , , max. 1 1/2max. HW10036B , ,6 12,9 60, max. 1 1/2max. Oil side Oil: ISO 40 C 36B 35B 34B 33B 32B 3,5 3,0 2,5 2,0 1,5 1,0 36B 35B 34B 33B 32B 31B 80 31B 0, factor Oil: ISO 40 C Multiplying for 0,7 0,9 1 1,1 1,5 2 Water side ,35 36B 35B 0,30 34B 33B 0,25 32B 31B Temperature correction factor T* C ,15 Multiplying for F 0,6 0,8 1 1,2 1,4 0,10 * T = Oil inlet temp. - Water inlet temp. 0,05 Water flow correction factor Water Flow l/ Multiplying for F 0,2 0,6 0,8 1 Water Flow (l/1 ) 3220 Oesse Oliekoelers - 156

57 HY SERIE USER S MANUAL 1. WARNINGS FOR THE USE AND SAFETY This instruction manual is an integrating part of the heat exchanger. We suggest to keep it safe and available during the entire life cycle of the present product. We suggest to read carefully all instructions and warnings this manual contains before to install the equipement. Installation must be done exclusively by qualified and experienced people, respecting the being in force norms. This equipement meets the european community laws requirements. The manufacturer declines every responsability in case of misuses or different uses from those allowed. The heat exchanger is intended exclusively for the use for which it has been developed; any other use must be considered improper and therefore dangerous. The manufacturer disclaims all responsability for possible damages to things and people due to the non-observance of these instructions or to improper use or to modifications carried out by non authorized personnel. DO NOT CLOG UP ANY VENTILATION OPENING OR HEAT DISSIPATION SURFACE After unpacking, make sure about integrity of the product. In case of doubt do not use the equipement and ask exclusively to qualified personel. Packaging must be disposed environmentally friendly. Before to connect the heat exchanger to the electrical supply be sure about: electrical plant must meet the norms in force of the country tension of the electrical net and frequency must be the same as indicated on the equipement the circuit mus be equipped with the earthing Before any maintenance or cleaning service make sure that electrical supply is disconnected. NEVER TRY TO REPAIR THE EQUIPEMENT. Never try to repair the equipement. As soon as the installation is finished make a short check following the instructions you'll find hereby. If the equipement does not work, disconnect the equipement from the electrical net and ask immediately the manufacturer. DON'T TOUCH THE EQUIPEMENT WHEN RUNNING. heat exchanger could have some very hot surfaces. During the working the DO NOT MOVE THE NUMBER PLATE. The product id plate contains technical data, limits of use, tracking number and production batch. The plate is an integrating part of the product and it must be always well readable Oesse Oliekoelers - 157

58 HY USER S MANUAL SERIE 2. USERS MANUAL AND MAINTENANCE SERVICE The oesse's air-oil heat exchangers are usually installed to cool down hydraulic circuits along the return line or in some case on independent cooling units ASSEMBLING AND INSTALLATION Make sure to install properly the heat exchanger on a suitable base which must be strong enough to support the weight using the brackets. Do not use any support foreseen for the housing or for the electrical motor. The heat exchanger must be installed according the sketch of fig. 1 in order to guarantee the best performances and make easier both scewing the connectors and maintenance. We suggest to place the oil inlet piping in a lower position than outlet and to use flexible tubes of the same diameter of the connectors without any adapter as showed in the fig. 2. Make sure that in the hidraulic circuit where the heat exchanger is installed the pressure peaks are lower than the max working pressure allowed. Oesse's heat exchangers allow a max dynamic pressure of 16 bar and a max static pressure of 21 bar. Before to make the electrical connections make sure that tension and frequency are the same as indicated in the technical form of the model and proceed with wiring according the sketch of fig. 3. In case of different applications, please ask our technical service. Fig. 1 minimum 1m. minimum 1m. M Fig Oesse Oliekoelers - 158

59 HY USER S MANUAL SERIE VDC Fig. 3 THERMAL SWITCH C K C VDC THERMAL SWITCH WIRING DIAGRAMS OF THE ELECTRICAL FAN VOLTS DC VOLT DC TYPE "A" TYPE "B" With IM 0,6 IC With IM 0,6 IC M M IM= Motor power IC= Max Thermal switch power TYPE "A" TYPE "B" THERMAL SWITCH C WIRING DIAGRAMS OF THE ELECTRICAL FAN 220 VOLT SINGLE PHASE U1= BLEU U1 Z U2 U2= BLACK M 1 Z= BROWN = YELLOW-GREEN R S T R S T WIRING DIAGRAMS OF THE ELECTRICAL FAN 220/380 VOLT THREE PHASE K C K C U1= BLACK U2= GREEN V1= BLEU V2= WHITE U1 V1 W1 U1 V1 W1 W1= BROWN W2= YELLOW = YELLOW-GREEN M 3 U2 V2 W2 M 3 K= REMOTE CONTROL SWITCH 9A C= THERMAL SWITCH DELTA CONNECTION U2 V2 W2 STAR CONNECTION 3220 Oesse Oliekoelers - 159

60 HY USER S MANUAL SERIE LIMITS OF USE Max temperature oil inlet Max ambient temperature Admitted fluids Max working pressure 120 C 50 C Mineral oils Synthetic oils Watre-glycol Oily/water emulsions 16 bar CHECK After installing the heat exchanger we suggest to pressurize the circuit to show possible oil outdraws. Feed the circuit checking that rotation of the fan and air flow are the same as the arrows on the housing indicates. FAN DIRECTION AIR FLOW SCHEDULED MAINTENANCE During maintenance make sure that all the elecrical sources are disconnected CLEANING Oil Circuit To clean the oil circuit it is necessary to disconnect the heat exchanger from the main hidraulic circuit. The cleaning must be done by circulating, in a counter current flux, a degreasing compound compatible with aluminium. In case of oil regeneration or substitution of the exhausted oil a deep cleaning of the inside oil circuit is recommended. Make sure there is no residue before to re-connect the heat exchanger to the circuit. Secondary circuit Disconnect the heat exchanger and protect adequately the electrical motor. For ordinary maintenance we suggest to keep the cooler surface clean by using a compressed air flow (max 8 bar) Oesse Oliekoelers - 160

61 HY USER S MANUAL SERIE HY SERIES In case of higly dusty or oily environments we suggest to disconnect and disassemble the heat exchanger, to spray the cooler surface with a degreasing compound and wash with a high pressure water. After this operation re-assemble the heat exchanger. WARNING: water flow must follow the same direction of the fins trying to avoid movements of the fan. Not proper cleaning or the use of aggressive compounds to aluminium or to some of the components of the heat exchanger may be cause of danger and can compromise the functioning LOCK We suggest to check regularly that screws and bolts are well tightened expecially on the equipements installed on vibrating units. We suggest a tightening torque of Max 40Nm. 3. ALTERATION Any alteration to the heat exchangers without written approval from Oesse, will compromise the warranty term as it will be considered as an equipement tampering. 4. STORING AND SHIPMENT The heat exchanger must be stored and shipped with the original packaging only, and in any case avoiding damages to anyone of his components. We recomend to store the heat exchanger at a proper temperature in order to avoid condensation inside the electrical circuits. For the shipment please refer to the weight shown on the box or on the technical form. 5. LUBRICANTS Oesse suggest to use mineral oils free of contaminating or damaging compounds. Do not waste any oil in environment. Oesse recommend to dispose the exhausted oil only trough the official authorized services. 6. DISPOSAL The heat exchangers of Oesse are manufactured using only full recyclable materials. Disposal can take place respecting the environment according the local law requirements Oesse Oliekoelers - 161

62 HY USER S MANUAL SERIE 7. TERMINOLOGY - SPARE PARTS ELECTRICAL MOTOR WITH FAN CONVEYOR CORE THERMAL SWITCH 8. STATEMENT OF CONTROL All the heat exchangers are submitted to a final check for the functioning and for the project conformity. The under mentioned stamp states that all checks has been passed. 9. STATEMENTS Oesse can supply, where available upon request, statements about the tests, experimental tests or trials executed on the products and available in the technical documentation c/o the manufacturer as required by the norms Oesse Oliekoelers - 162

63 HY USER S MANUAL SERIE 10. WARRANTY CERTIFICATE The present warranty covers possible manufacturing defects of the heat exchanger for a period of one year from the purchasing date proved by valid fiscal document. For any extension please apply to the manufacturer. In order to have an operating warranty it is necessary to keep the warranty certificate together with a valid document quoting the description details of the product. Warranty means the replacement or the repairing of the parts of the equipment which turn out to be defective at the origin for manufacturing defects In case of irreparable or repeated defect at the same origin, upon unquestionable decision of the manufacturer, the equipment will be replaced. The warranty on the new equipment will continue till the end of the original contract In case the equipment shows defects which are not covered by the warranty and the warranty itself has expired, all the transport costs will be at the customer's expense The warranty is no longer valid if the parts turn out to be defected due to carelessness or negligence in using, wrong installation or maintenance, maintenance operated by unskilled personnel, transport damages or any circumstance unrelated to manufacturing defects of the equipment. All the operations concerning the installation and the connection to the feeding systems are excluded from the warranty. Warranty is excluded in case of normal wear of the equipment and of marginal defects which have a negligible effect on the value or the working of the equipment. Furthermore warranty is excluded in any case of incorrect use of the equipment Warranty is applied for customers in order with payments. The manufacturer disclaims all responsability for possible damages which can directly or not affect people, things or animals due to the non-observance of the above instructions. OESSE S r l 3220 Oesse Oliekoelers - 163

64 3220 Oesse Oliekoelers - 164

Oil/Air Cooler Units. Compact application with AC Motor OK-ELC Type. Test procedure certified following EN 1048

Oil/Air Cooler Units. Compact application with AC Motor OK-ELC Type. Test procedure certified following EN 1048 COMPACT OIL / AIR COOLERS NEW COMPACT DESIGN WITH AC ELECTRIC FANS AND HIGH COOLING PERFORMANCE Application These coolers are designed specifically for hydraulic applications where high performance and

More information

90C COMPRESSOR KIT PART NO C COMPRESSOR KIT PART NO C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO.

90C COMPRESSOR KIT PART NO C COMPRESSOR KIT PART NO C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO. 90C COMPRESSOR KIT PART NO. 00090 92C COMPRESSOR KIT PART NO. 00092 95C COMPRESSOR KIT 12V PART NO. 00095 95C COMPRESSOR KIT 24V PART NO. 02495 90C 92C 95C IMPORTANT: It is essential that you and any other

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X Variable Vane Pump, Direct Controlled PV7...A Series 1X / X RE 1 Issue: 1.1 Replaces: 8.8 Sizes 1 to Maximum pressure 1 bar Displacement volume 1 to cm Features Very short control times Low noise Mounting

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05 TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Air Compressor Piston Trouble Shooting Guide

Air Compressor Piston Trouble Shooting Guide Motor Will Not Run. Power not on Turn power on (Failure to start) 1 Blown main fuses (size 175% of motor nameplate) Blown control fuses (size per nec article 450-3) Breaker tripped Safety device tripped

More information

Pump-Transfer Cooler Filtration Unit UKF

Pump-Transfer Cooler Filtration Unit UKF Pump-Transfer Cooler Filtration Unit UKF Symbol General The UKF unit is a compact, easy-to-install system for offline filtration cooling circuits. It consists of a low-noise feed pump, a filter and a plate

More information

Oil / Air Cooling Units for mechanical engineering and mobile hydraulics

Oil / Air Cooling Units for mechanical engineering and mobile hydraulics Oil / Air Cooling Units for mechanical engineering and mobile hydraulics ViFlow Finland Oy Kauppakartanontie 7 A 1 00930 Helsinki, Finland tel. +358 40 178 0920 fax +358 9 4789 2800 viflow@viflow.fi www.viflow.fi

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

Espresso coffee grinder

Espresso coffee grinder Espresso coffee grinder 40A Espresso grinder 40A (Grey model) Internationally patented models L o n g l i f e, d e s i g n a n d s i l e n c e Silent espresso Fresh ground coffee gives the best espresso

More information

Installation & Operation Maintenance Manual

Installation & Operation Maintenance Manual 2 Stage Oil Flooded Type Reciprocating Air Compressors Installation & Operation Maintenance Manual Models CRAC-D5H CRAC-D10H CRAC-D20H CRAC-D5V CRAC-D7.5V CRAC-D7.5H CRAC-D15H CRAC01-02 Rev. REL. Model

More information

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7 Ø 5 ±. DC Electropumps Bull,5 Rotation,5 5,7 Email: sales@hydronit.com Fax B... Electro pumps Bull series MODEL CODE EPB,5 DC /S5 K, V** Electro Pump Bull series Gear pump displacement (cc/rev (see tables

More information

Pump-Transfer Cooler Filtration Unit UKF-1

Pump-Transfer Cooler Filtration Unit UKF-1 Pump-Transfer Cooler Filtration Unit UKF-1 Pump-transfer cooler filtration unit UKF-1 1. Description 1.1 General The UKF-1 unit is a compact, easy-to-install unit for offline filtration cooling circuits.

More information

Hydraulic control unit series 0086-372-01

Hydraulic control unit series 0086-372-01 Technical Product Information No. 1290 EN Hydraulic control unit series 0086-372-01 Contents Page About this Technical Product Information (TPI) 2 The ORTLINGHAUS numbering system 2 About the product 3

More information

300 Series PA Pump and Cooler Assemblies

300 Series PA Pump and Cooler Assemblies Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate

More information

INSTALLATION INSTRUCTIONS FOR MINI MAKE-UP AIR MODEL FER

INSTALLATION INSTRUCTIONS FOR MINI MAKE-UP AIR MODEL FER INSTALLATION INSTRUCTIONS FOR MINI MAKE-UP AIR MODEL FER May 2012 VERSION 1.3 Please read instructions carefully before installation. This unit is a complete fresh air make-up package with an integrated

More information

Pump-Transfer Cooler Filtration Unit UKF-3 / UF-3

Pump-Transfer Cooler Filtration Unit UKF-3 / UF-3 Pump-Transfer Cooler Filtration Unit UKF-3 / UF-3 Pump-transfer cooler filtration unit UKF-3/ UF-3 1. Description 1.1 General The UKF unit is a compact, easy-to-install unit for offline filtration cooling

More information

Packaged Air Conditioner - Water Cooled Vertical Type Model 25

Packaged Air Conditioner - Water Cooled Vertical Type Model 25 Refrigerant R407C CX Packaged Air Conditioner - Water Cooled Vertical Type Model 25 8.0kW CX 25 1 Product Code Model Power supply Product code CX 25 230V / 1 ~ / 50 Hz 7XU012153 CX 25 CX 25 2 CX 25 General

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

3 Screw Pump Type. SEIM - PCX Model Users Manual

3 Screw Pump Type. SEIM - PCX Model Users Manual 3 Screw Pump Type SEIM - PCX Model Users Manual Main Index 1.0 Foreword 1.1 Notes about the manual 1.2 Symbols used 1.3 Pump identification 1.4 Product Warranty 1.5 General notes on delivery 2.0 Plant

More information

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of

More information

Transformer oil cooler ALFA A02

Transformer oil cooler ALFA A02 A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using

More information

325C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO.

325C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO. 325C AIR COMPRESSOR KIT PART NO. 32530-32533 - 32534-32538 350C AIR COMPRESSOR KIT PART NO. 35030-35033 400C AIR COMPRESSOR KIT PART NO. 40040 450C AIR COMPRESSOR KIT PART NO. 45040 325C 350C 400C 450C

More information

Installation, operation and maintenance manual TX 35A

Installation, operation and maintenance manual TX 35A Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2

More information

OPERATING INSTRUCTIONS FOR ELECTRODE SHARPENING MACHINE WIG 4

OPERATING INSTRUCTIONS FOR ELECTRODE SHARPENING MACHINE WIG 4 OPERATING INSTRUCTIONS FOR ELECTRODE SHARPENING MACHINE WIG 4 Original Please keep for further use! Kaindl-Schleiftechnik REILING GmbH, D-75203 Königsbach-Stein, Remchinger Str. 4 Germany Tel.: +49 7232/4001-0,

More information

200 PSI COMPRESSORS - MODEL NUMBERS

200 PSI COMPRESSORS - MODEL NUMBERS 200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read

More information

STC 3S012-020-A Series Solenoid Valves

STC 3S012-020-A Series Solenoid Valves STC 3S012-020-A Series Solenoid Valves 3S012-020-A Series Solenoid Valve Specifications Valve Model 3S012-1/8-A 3S012-1/4-A 3S020-1/8-A 3S020-1/4-A Port Size (NPT) 1/8 1/4 1/8 1/4 Valve Type Action 3 Way,

More information

Fixed displacement vane pumps

Fixed displacement vane pumps Fixed displacement vane pumps RE 1335/1.5 Replaces: 11.2 1/22 Types PVV and PVQ Nominal sizes 18 to 193 Series 1X Maximum operating pressure 21 bar Maximum displacement 18 to 193 cm 3 Doppelpumpe_d_ Double

More information

Float and Thermostatic Traps Series H, C and X

Float and Thermostatic Traps Series H, C and X Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT

More information

INFRARED QUARTZ WALL HEATER

INFRARED QUARTZ WALL HEATER INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this

More information

Modular Compact Power Units nominal value of valves NG 4 and NG 6 (CETOP 2 and 3)

Modular Compact Power Units nominal value of valves NG 4 and NG 6 (CETOP 2 and 3) Modular Compact Power Units nominal value of valves NG 4 and NG 6 (CETOP 2 and 3) deliverable in short time available in execution TEX GIRMTIC G adstrasse 14 CH-8590 Romanshorn Phone: +41 71 466 15 15

More information

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and

More information

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER

More information

280C AIR COMPRESSOR KIT

280C AIR COMPRESSOR KIT 280C AIR COMPRESSOR KIT PART NO. 28021 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product.

More information

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury. 1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is

More information

Installation and safety instructions for AC/DC built-in devices

Installation and safety instructions for AC/DC built-in devices The device type and date of manufacture (week/year) can be found on the device rating plate. In the event of any queries about the device, please quote all the details given on the rating plate. For further

More information

FBM RANGE. Fitting Instructions and User Guide

FBM RANGE. Fitting Instructions and User Guide FBM RANGE Fitting Instructions and User Guide 1 NOTICE TO INSTALLER These water heater have a built in cold water feed cistern and float valve and can supply a number of hot water outlets. As the hot water

More information

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html

More information

MSQ18LA. Nitrogen Generator for Mass Spectrometers

MSQ18LA. Nitrogen Generator for Mass Spectrometers MSQ18LA Nitrogen Generator for Mass Spectrometers User Manual Document No. 065779 November 2008 2008 by Dionex Corporation All rights reserved worldwide. Printed in the United States of America. This publication

More information

Pressure relief valves type AGAM two stage, subplate mounting - ISO 6264 size 10, 20 and 32

Pressure relief valves type AGAM two stage, subplate mounting - ISO 6264 size 10, 20 and 32 www.atos.com Table C06619/E Pressure relief valves type AGAM two stage, subplate mounting ISO 6264 size 10, 20 and 32 1 MODEL CODE AGAM10/11...E AGAM20/.../V AGAM are two stage pressure relief valves with

More information

Piston rod cylinder Diaphragm actuator, power transducer and pressure intensifier Series RDC. Brochure

Piston rod cylinder Diaphragm actuator, power transducer and pressure intensifier Series RDC. Brochure Piston rod cylinder Diaphragm actuator, power transducer and pressure intensifier Brochure 2 Piston rod cylinder Diaphragm actuator, power transducer and pressure intensifier Diaphragm and piston actuators,

More information

543-0032-00, 943-0032-00. User s Manual

543-0032-00, 943-0032-00. User s Manual 543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and

More information

High Pressure Gear Pumps KP 0

High Pressure Gear Pumps KP 0 High Pressure Gear Pumps KP 0 2 KRACHT GmbH Gewerbestr. 20 58791 Werdohl, Germany fon +49(0)23 92/935-0 fax +49(0)23 92/935 209 mail info@kracht.eu web www.kracht.eu Construction According to its design,

More information

Air Cooler Industry AC-LN 8-14 MI with integrated frequency inverter

Air Cooler Industry AC-LN 8-14 MI with integrated frequency inverter Air Cooler Industry AC-LN 8-14 MI with integrated frequency inverter Symbol General The AC-LN MI air cooler series can be used in all areas where either oil or water-glycol has to be cooled with air. The

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

TECHNICAL INFORMATION Models No. Description

TECHNICAL INFORMATION Models No. Description TECHNICAL INFORMATION Models No. Description HP2070, HP2070F, HP2071, HP2071F 20mm (3/4") 2-Speed Hammer Drill CONCEPT AND MAIN APPLICATIONS L W NEW TOOL P 1 /13 W L These hammer drills have been developed

More information

RHINO MOTION CONTROLS

RHINO MOTION CONTROLS Installation Manual and Datasheet Page 1 Key Features Smooth and quiet operation at all speeds and extremely low motor heating Industrial grade performance for 2-Phase Bipolar and Uni-polar Stepper Motors

More information

Operating Instructions

Operating Instructions Operating Instructions Plug > Contents 1 Contents 1 Contents...2 2 General Information...2 3 Safety instructions...3 4 Conformity to standards...3 5 Function...3 6 Technical Data...4 7 Mounting...6 8 Installation...7

More information

FLUTEC Pressure Relief Valves

FLUTEC Pressure Relief Valves FLUTEC Pressure Relief Valves Pressure Relief DB4E 1.1. up to 630 bar up to 30 l/min Connection housings 2 1. DESCRIPTION 1.1. GENERAL According to DIN -ISO 1219, DB4E are valves for oil hydraulic systems

More information

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls www.atos.com Table A609/E Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls PVPCCH4046 PVPC are variable displacement axial piston pumps for high pressure operation,

More information

MEMBRANE VACUUM MINI PUMPS

MEMBRANE VACUUM MINI PUMPS MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free

More information

X AC GEARLESS

X AC GEARLESS 3141 en - 02.1999 / a This manual is to be given to the end user X20 30 36 AC GEARLESS Installation and maintenance In order to obtain complete satisfaction from your new LEROY SOMER gearless machine,

More information

Split units TH with hermetic compressors

Split units TH with hermetic compressors Split units TH with compressors Refrigeration units in split variant. Available with screw or solder terminal. Condensing unit with sound insulated weatherproof housing for outdoor installation. Split

More information

Instructions for operation ST 152 ST 205

Instructions for operation ST 152 ST 205 Instructions for operation ST 152 ST 205 1 Contents General instructions...3 Safety instructions...3 Explanation of hazard labels...4 Residual risk...4 Description of components...5 Assembly...7 Electrical

More information

INSTALLATION AND USER GUIDE

INSTALLATION AND USER GUIDE EN POOL EQUIPMENT KLIN GOTHIC ITC DEMI-13,3 b zlatá černá PANTONE 871 U Swimming Pool Heat Pump XHP PANTONE 426 U INSTALLATION AND USER GUIDE i Read the instructions Illustrative photo Contents 1. Specification...3

More information

TBT125, TBT160A, TBT295B

TBT125, TBT160A, TBT295B Tollobelt TBT125, TBT160A, TBT295B and TBT295W Installation and service manual TOLLO LINEAR AB SWEDEN DW110358gb-0352-edition2 Table of Contents Section 1 Introduction... 2 Section 2 Type designation system...

More information

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920 USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920 [This page intentionally left blank] Warning for Your Protection 1. Read these instructions. 2. Keep these

More information

2/2 and 3/2 Way Size 6 Seat Valves

2/2 and 3/2 Way Size 6 Seat Valves 2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08

More information

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17) 17 Engine-Lubrication system (Page GR-17) Lubrication system components, removing and installing Oil pan, removing and installing Oil pressure and oil pressure switch, checking Dynamic oil pressure warning

More information

Flow Switches Type / 1220

Flow Switches Type / 1220 Type 1200... / 1220 Installation, operation and maintenance instructions Type 1200B Contents Type 1220B 1. UNIT INSTALLATION page 1 1.1 Std box housing orientation page 1 2. COMMISSIONING page 1 3. ALARM

More information

DC to AC Power Inverters

DC to AC Power Inverters Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121309B OWNERS

More information

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Ergo-Pro Single Line Solar Station Installation and Operating Instructions Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating

More information

VALVES N.C. FOR REFRIGERATING SYSTEMS

VALVES N.C. FOR REFRIGERATING SYSTEMS SOLENOID VALVES 11 VALVES N.C. FOR REFRIGERATING SYSTEMS APPLICATIONS The valves illustrated herein are designed for use with refrigerant fluids CFC, HCFC and HFC. OPERATION All valves are normally closed

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

Rexroth Hydraulics. Vane pumps, direct controlled Type PV7...A RE 10 520/10.97

Rexroth Hydraulics. Vane pumps, direct controlled Type PV7...A RE 10 520/10.97 RE 1 52/1.97 Replaces: 12.95 Vane pumps, direct controlled Type PV7...A Nominal sizes 1 to 25 Series 1X Maximum operating pressure 1 bar Displacements from 1 to 25 cm 3 H/A 4617/95 Type PV7-1X/..RA1MA-...

More information

1 High pressure washer 2 Wheel 3 Inlet connector 4 Outlet connector 5 Handle 6 Trigger gun 7 Detergent bottle. Technical Data:

1 High pressure washer 2 Wheel 3 Inlet connector 4 Outlet connector 5 Handle 6 Trigger gun 7 Detergent bottle. Technical Data: 1 High pressure washer 2 Wheel 3 Inlet connector 4 Outlet connector 5 Handle 6 Trigger gun 7 Detergent bottle Technical Data: Rated pressure Permissible pressure (max.) Inlet (max.) Rated flow Max. flow

More information

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER P110 Your battery charger has been engineered and manufactured to Ryobi s high standard for dependability, ease of operation, and operator safety. When properly

More information

Manual Code VR-197-0-0002

Manual Code VR-197-0-0002 USE, MAINTENANCE AND INSTALLATION MANUAL AIR CONDITIONERS FOR ELECTRICAL ENCLOSURES Manual Code VR-197-0-0002 VZ1550 VZ1850 VZ1400 VZ2000 ABB SACE S.p.A. An ABB Group Company Automation and Distribution

More information

STC 2S Series Solenoid Valves

STC 2S Series Solenoid Valves STC 2S025-050 Series Solenoid Valves 2S025-050 Series Solenoid Valve Specifications Valve Model 2S025-1/4 2S035-1/4 2S040-3/8 2S050-1/4 2S050-3/8 Valve Type Action 2 Way, Normally Closed (NC) Direct Acting,

More information

Cod. 252.155.10 CUCINE CON PIANO IN VETROCERAMICA COOKERS WITH PYROCERAM TOPS MOD. 60/30 PVE MOD. 60/60 PVE MOD. 60/30 PVE MOD.

Cod. 252.155.10 CUCINE CON PIANO IN VETROCERAMICA COOKERS WITH PYROCERAM TOPS MOD. 60/30 PVE MOD. 60/60 PVE MOD. 60/30 PVE MOD. ~ ~ Cod. 252.155.10 CUCINE CON PIANO IN VETROCERAMICA COOKERS WITH PYROCERAM TOPS MOD. 60/30 PVE MOD. 60/60 PVE MOD. 60/30 PVE MOD. 60/60 PVE INDEX Paragraph Instructions for the installer 1 Compliance

More information

Nitrogen generator model ZEFIRO 3-5. User s manual

Nitrogen generator model ZEFIRO 3-5. User s manual Nitrogen generator model ZEFIRO 3-5 User s manual Version 2.00 Strumenti Scientifici Cinel, via dell Artigianato, 14-14/A 35010 Vigonza (PD) Tel. 049725022 Fax 0498931881 e-mail: info@cinel.com www.cinel.com

More information

Thermal safety drain valve Series STS.S

Thermal safety drain valve Series STS.S Thermal safety drain valve Series STS.S Main features - Double safety - 0 swivel connection of capillary - Available with different drain temperature settings: C, 8 C, 9 C, 9 C and 0 C - Installation in

More information

ARC INVERTER INSTRUCTION MANUAL

ARC INVERTER INSTRUCTION MANUAL ARC INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4

More information

ENGINE COOLING (6VD1 3.2L)

ENGINE COOLING (6VD1 3.2L) ENGINE COOLING (6VD1 3.2L) 6B 1 RODEO ENGINE ENGINE COOLING (6VD1 3.2L) CONTENTS Service Precaution...................... 6B 1 General Description..................... 6B 2 Diagnosis..............................

More information

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT POSEION 2-29, 2-25 & 2-22 POSEION 2-29, 2-25 & 2-22 XT Repair Manual Index A. Safety precautions 3 B. Technical data 4 C. Structure 5-6. Service / Repair 7-23 E. Tools 24 F. Function 25-26 G. Electric

More information

Linear-Stages series 5101

Linear-Stages series 5101 User s Manual Linear- Huber Diffraktionstechnik GmbH & Co. KG Sommerstrasse 4 D - 83253 Rimsting Phone +49 (0) 8501 6878-0 Fax +49 (0) 8051 6878-10 info@xhuber.com www.xhuber.com User s manual Linear-Stages

More information

OIL SEPARATORS. 112

OIL SEPARATORS. 112 OIL SEPARATORS 111 OIL SEPARATORS APPLICATIONS The oil separators, shown in this chapter, are classified Pressure vessels in the sense of the Pressure Equipment Directive 97/23/EC, Article 1, Section 2.1.1

More information

AXIAL PISTON PUMP - J9V

AXIAL PISTON PUMP - J9V TROUBLE SHOOTING The information contained in this section provides a guide for troubleshooting the pumps. It is a problem solving tool aimed at reducing unnecessary machine downtime. Following the fault-logic

More information

Product Manual Ridder RW45 Motor Gearbox 1-phase (3-wire)

Product Manual Ridder RW45 Motor Gearbox 1-phase (3-wire) Product Manual Ridder RW45 Motor Gearbox 1-phase (3-wire) 265056EN - V03-2016.04 Lorentzstraat 36-38 3846 AX Harderwijk P.O. Box 360 3840 AJ Harderwijk the Netherlands T +31 (0)341 416 854 F +31 (0)341

More information

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact: 7610.478.16 8/99 INSTRUCTION MANUAL Models 8005, 8010, 8015 For Sales & Service please contact: CENTRAIR Air Systems & Supplies Phone: 705-722-5747 Fax: 705-722-5458 Email: sales@centrair.ca Website: www.centrair.ca

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED

More information

H -S S -O S SERVICE MANUAL. Rev: Page 1 Hydro-Sync Slide-out System Service Manual

H -S S -O S SERVICE MANUAL. Rev: Page 1 Hydro-Sync Slide-out System Service Manual H -S S -O S SERVICE MANUAL Rev: 01.12.2015 Page 1 Hydro-Sync Slide-out System Service Manual TABLE OF CONTENTS Safety Information 3 Product Information 3 Operation 4 Extending Slide-out Room 4 Retracting

More information

TIG INVERTER INSTRUCTION MANUAL

TIG INVERTER INSTRUCTION MANUAL TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4

More information

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850 INSTALLATION AND OPERATING INSTRUCTIONS KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850 Product advantages Automatic float switch as water

More information

CYMAQ Marking System AS200 + DS7050 N-14

CYMAQ Marking System AS200 + DS7050 N-14 CYMAQ Marking System AS200 + DS7050 N-14 Serial Number: 13716 CYMAQ www.cymaq.com INDEX 1. PRESENTATION AND GENERAL POINTS 1.1. General Points 1.2. Identification plate 2. MACHINE CHARACTERISTICS 2.1.

More information

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name. ITE Indirect calorifier ITE - 400/500/600/750/1000 0310 117 Installation, User and Service Manual Innovation has a name. Read this manual carefully Warning Read this manual carefully before starting the

More information

A/C-HEATER SYSTEM - MANUAL

A/C-HEATER SYSTEM - MANUAL A/C-HEATER SYSTEM - MANUAL 1995 Toyota 4Runner 1995-96 Manual A/C-Heater System 4Runner * PLEASE READ THIS FIRST * WARNING: To avoid injury from accidental air bag deployment, read and carefully follow

More information

Hotstore Stainless Steel Thermal Store Cylinder

Hotstore Stainless Steel Thermal Store Cylinder Hotstore Stainless Steel Thermal Store Cylinder Installation Guidance and Operating Instructions L318 General: These instructions must be read before undertaking installation or maintenance of Hotstore

More information

ASL Series Pump. Operation and Maintenance Manual Air Driven, High Pressure Liquid Pump

ASL Series Pump. Operation and Maintenance Manual Air Driven, High Pressure Liquid Pump ASL Series Pump Operation and Maintenance Manual Air Driven, High Pressure Liquid Pump Catalog: 02-9233ME February 2013 Model # Serial # Drawing # Order # Mfg. Date Table of Contents page 1.0 Introduction...

More information

Infrarot-Bewegungsmelder IP44

Infrarot-Bewegungsmelder IP44 Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion

More information

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls www.atos.com Table A60/E Axial piston pumps type PVP variable displacement, by a full line of mechanical controls PVPH4046 PVP are variable displacement axial piston pumps for high pressure operation,

More information

This instruction is valid for all ACD pump models shown on page 2

This instruction is valid for all ACD pump models shown on page 2 Screw pumps ACD Maintenance and Service Instruction This instruction is valid for all ACD pump models shown on page 2 Contents Page List of components 2 Exploded view/ordering code 3 Service intervals

More information

1. SPECIFICATION Cooling system Type Water cooling, forced circulation Coolant Capacity Approx. 8.5 liter

1. SPECIFICATION Cooling system Type Water cooling, forced circulation Coolant Capacity Approx. 8.5 liter 000000 083 1. SPECIFICATION Description Specification Cooling system Type Water cooling, forced circulation Coolant Capacity Approx. 8.5 liter Radiator Antifreeze Core size 740W X 380H X 27t (over 281,200

More information

Part I - Installation

Part I - Installation 400 Series Pressure and Differential Pressure Switches Types: H400, H402, H403, H400K, H402K, J400, J402, J403, J400K, J402K UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please read

More information

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 19 Engine-Cooling system (Page GR-19)

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 19 Engine-Cooling system (Page GR-19) 19 Engine-Cooling system (Page GR-19) Cooling system components, removing and installing Coolant hose connection diagram Coolant pump, removing and installing Cooling system components (body side), removing

More information

SunMaxx Solar Filling Station Operating Instructions

SunMaxx Solar Filling Station Operating Instructions SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...

More information

Thermostatic valve Type AVTA

Thermostatic valve Type AVTA MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The

More information

RHINO MOTION CONTROLS

RHINO MOTION CONTROLS Installation Manual and Datasheet Page 1 Key Features Smooth and quiet operation at all speeds and extremely low motor heating Industrial grade performance for an alternating current servo motor Field

More information