1 PUM Series Multi-loop module type Temperature controller Smart! Optimum multiple-zone control Heater break alarm CT ( points) Program-less host communication User friendly! Detachable terminal Simple loader operation Fast! High-speed data communication (.kbps ) High-speed data sampling ECNO:a

2 FETURES Smart! Heater break alarm CT ( points) Optimum multi-zone control User application module User friendly! Programless communication with upper device Fast! Detachable terminal structure Simple loader on the Personal Computer Easy to attach to the DIN rail SV SV High-speed communication with upper device PUM series. High-speed sampling time P

3 PPLICTIONS Case Input/output device of I/O units in programmable logic controller <Separated PLC type> Case Temperature controller <Multi Temperature controllers type> <Reflow soldering device> <Flat panel display baking furnace> Oven <Plastic injection machine> <Plastic extrusion machine>

4 VRITIONS Temperature control Digital input/output nalog input/output Kind Control Module Features Event input/output Module Features nalog input & output Module Features nalog input Module Features nalog output Module Features Features Features Features PUM/B PUME PUMV PUMN PUMT PUMCL PUMCM PUMCP Type See page High performance Support Tools Peripheral instrument ccessory Kind PROFINET Module <Now developing> Features User pplication Module Features Programming Loader on Personal computer Features Programmable Operation Display Features utomation Software Features pplicable standards PUMCE PUML Type PUM/B PUME PUMV PUMN PUMT PUMCL PUMCM PUMCP PUMCE PUML See page none none

5 SYSTEM CONSTRUCTION FOR EXMPLE Basic system (minimum system construction) In case of minimum system construction, ch or ch RS- communication is standard, not option * When you use the heating and cooling control, PUM can control max. channels and PUMB can control max. channel. Basic system (maximum system construction) When you use analog input/output, or digital input/output in addition to ch/ch control module. You can construct up to units for control, and analog input/output type (control module, analog input/output) plus up to units for digital input/output type (event module). Setting St. numbers is necessary for internal communications. (Station No.= setting value of Station No. configuration switch +) Make sure that there is no duplicate station number ( to ) in control type, analog type series. Make sure that there is no duplicate station number ( to ) in event type series. You can use the duplicate station number between control type, analog type series and event type.

6 Enhanced communication type Performing CC-LINK communication, PLC program-less communication, and PROFIBUS communication. Enhanced communication module is connected to the left end of control type, analog type series and event type. Optimum control Performing optimum multiple-zone control or other user applications User application module is connected on the extreme right of analog type series and Event type.

7 COMMUNICTION MODULE - Modbus protocol s (lateral connections of a maximum of modules) Control Module, nalog I/O Module are units maximum and Event I/O Module are units maximum. Upper communication RS- with.kbps maximum - Modbus potocol s (distibuted allocations) Control Module, nalog I/O Module are units maximum and Event I/O Module are units maximum. Upper communication RS- with.kbps maximum Maximum units with nalog type Module and Event type Module - CC-Link protocol s (distributed allocations) Control Module, nalog I/O Module are ch maximum CC-LINK Mbps maximum systems maximum (one CC-Link Module occupies stations)

8 - Mitsubishi's PLC with programless communications (Continuance connections by maximum) Control Module, nalog I/O Module are units maximum and Event I/O Module are units maximum. RS-, RS- or RSC with. kbps maximum - Mitsubishi's PLC with programless communications (distributed allocations) Control Module, nalog I/O Module are units (ch) maximum and Event I/O Module are units maximum RS/ with.kbps maximum systems maximum - PROFIBUS s (distributed allocations) system maximum Control Module, nalog I/O Module are units maximum and Event I/O Module are units maximum for one system) PROFIBUS-DP Mbps maximum systems maximum

9 LODER SOFTWRE PUM series are prepared by loader software. This software is supported by windows PC. Basic Loader for Control Module, nalog I/O Module, and Event I/O Module and Enhanced Module (except for CC-Link communication type) Free software It is available to download for Fuji s HP. This URL is c-net.jp SMRT LODER You can set the all modules with the loader ports on the control modules without replacing cables. There are two kinds of modules; the master and the slave. (ll modules are set to slave in shipping, and they can be set as master by the loader software) Only the master is capable of setting and display of all modules, and those of slave is individual. Only unit can be set as the master in all modules. When two or more master exists, correct operation is not performed. When operating the parameters of the enhanced communication module, connect the loader connecting cable to the loader communication port of the enhanced communication module. You can grasp the whole control conditions easily by monitoring parameter display, setting, and control conditions. ESY LODER You can operate this software without having the instruction manual! This software has PULL DOWN MENU, and detailed online help. Editing display is tree style, and it is easy to search your parameter needs. BILINGUL LODER English version and Japanese version be selected initial configurations. PRMETER SETTINGS and NMES OPTIMIZE TO MEET CUSTOMER'S REQUIREMENT If you can use favorite function on software, it is easy to access time important parameters. It can change the name of each parameters at any time. Basic function Connection Setting, displaying, editing the parameters Display the construction of all modules DT trending (data trend display function, trend data display function in CSV format) Utility function (copy the same parameters, printing and saving data by CSV files) s (Upload, Download, Saving in files, Opening files) Only original connection cable, but it is same as PXH or PXG cable. Original cable : MODEL PUMZL, Pin-jack -pole, D-sub pin Handling model Recommended environment of personal computer CONTROL MODULE : MODEL PUM/PUMB NLOG I/O MODULE : MODEL PUMV/PUMN/PUMT EVENT I/O MODULE : MODEL PUME ENHNCED COMMUNICTION MODULE : MODEL PUMCM/PUMCP OS: WINDOWS, WINDOWS XP (Global version and Japanese local version) CPU: MHz MEMORY: MB over FREE SPCE in Hard Disk: over MB CD-ROM drive : necessary MONITOR: over

10 Feature Citect SCD SOFTWRE Citect can support your system development by expanding function, reliability, great visual. The perfect redundant functions, HMI, Server client, duplication of LN, these functions are standard. Hi-speed access to huge data-base with low load of CPU working. The small system for points below is matching, and the large system for, points over is possible. It is not need to stop the operating system now for change expansion function. License s up-grade is available Trend display It is possible for trend sampling that cyclic type or situation of event causing type. The sampling interval is setting from ms to hours. It is possible to change the area and graphic mode until execute the trending. Trending display of Citect SCD can add more trend-pen when the project is now executing. If you can push zoom button, expand the your selecting area. If you can push trend statistics button, display the minimum, maximum, average, and standard deviation. Clip-board copy function can be pasted the spread-sheet data on third-party software. The trending data is able to be printed that the color is direct impression display, or mono-tone display. It is possible to compose the trending fi gure on the Citect s report. MONITOUCH V series For optimal performance, connectivity and usability. The MONITOUCH V series has expanded the potential of programmable operator interface panels. Realize the Ideal High Performance The new MONITOUCH series has realized the best possible performance with a newly developed high-speed algorithm and a high level of visibility for efficient operation. Connectivity -way communication with up to eight kinds of devices and two USB channels ensure high compatibility and expandability of your system. Usability User-friendly component parts and functional switches enable simple and speedy display configuration. Network Examples Serial connection with PUM series (three ports) Making a network linked with various automation devices PLCs and peripherals of up to three kinds of units can be connected by serial connection. Even though two or more types of temperature controllers and inverters are used, they can be connected with one V.

11 Specifications of PUM series Control Module Type : PUM/B Process value input No. of input Input signal Measurement range and input type Measurement accuracy (Ta= C) or points ( point/channel) Select from group I or II on the model code. (setting can be done according to channel with in group) Group I : Thermocouple Resistance bulb (-wire): Pt, JPt Group II : DC voltage, current DC to V, DC to V, DC to V, DC to V DC to m, DC to m * The power current input is external in ohm resistance. It's input of DC to V or DC to V Range. See table Thermocouple : ±.%FS±digit± degree C or ± degrees C whichever is greater *Unless B thermocouple to degrees C : ±%FS±digit± degree C R thermocouple to degrees C : ±%FS±digit± degree C T thermocouple - to degree C : ±.%FS±digit± degree C Resistance bulb input : ±.%FS±digit or ± degree C whichever is greater Voltage / Current input : ±.%FS±digit Resolution See table Temperature ±.%FS/ degrees C fl uctuation Input sampling ms cycle Input impedance Thermocouple: M ohm or more Current input : ohm Voltage input : approx. M ohm Infl uence of signal source resistance llowable wiring resistance llowable input voltage Noise rejection ratio Input compensation Over range, under range Thermocouple: ±.%FS±digit / ohm Voltage input : ±.%FS±digit / ohm Resistance bulb: ohm or less (per wire) DC voltage input: within ±V Current input: within ±m Thermocouple/resistance bulb: within ±V Normal mode: db or more (/Hz) Common mode: db or more (/Hz) between process value input and earth ground, power supply, output Vac, /Hz a) User adjustment: zero point, span point ±%FS b) PV shift: ±%FS c) First order lag filter :. to. sec. Out of range of - to %FS (ccuracy cannot be ensured for - to, to %FS) Functional insulation between channels, and with any other input/output Heater break detector (CT) input No. of input Input type Current detection accuracy Time required for detection Connection Control output No. of output Control output behavior or points ( points/control ch.) Single-phase type CT /point to : CTL--S-H to : CTL--S- Input value ±% or ±, whichever is greater ON detection: ms or more OFF detection: sec. or more Connector for heater break detector [on the front of module] No insulation between channels No insulation with communication port (RS-, loader) Function insulation with any other input/output points ( point/ch.) or points ( points/ch.) Heat (reverse action) or cool (direct action), or heat/ cool (control output points/loop required) Output type Selected from to (by channels) Relay contact output - Proportional cycle : to sec. - Contact structure : a (SPST) contact - Contact capacity : Vac/Vdc, (resistance load) Vac/Vdc, (inductive load) - Min. switching current: m (V DC) - Mechanical life:,, switching or more(/min.) - Electric life:, switching or more (rated load) - : Basic insulation with any other input/ output SSR/SSC drive output - Proportional cycle : to sec. - Minimum resolution : ms - ON voltage : Vdc ( to Vdc) - OFF voltage :.Vdc or less - Max. current : mdc (per point) - Load resistance : ohm or more - : No insulation with any other output (excluding relay output) Functional insulation with others than those above Current output ( to mdc, to mdc) - ctual output range : m to.mdc - ccuracy : ±.%FS (less than m : ±%FS) - Linearity : ±.%FS (less than m : ±%FS) - Resolution :, or more - Ripple current : P-P.m or less - Load resistance : ohm or less - : No insulation with any other output (excluding relay output) Functional insulation with others than those above nalog re-transmission output No. of output Output type Option RS- interface standards No. of port, synchro speed distance Recommended cable No. of connectable units Data format Protocol points (OUT, OUT applied) Current output ( to mdc, to mdc) Output scaling RS- compatible port Two-wire, half-duplex, asynchronous cycle.k,.k,.k,.kbps km (.kbps or less), m (.kbps) KPEV-SB.sq-equivalent units (master and slave)( units if any modules other than PUM series are included in slaves.) Data bit;, parity; even / odd / none Modbus RTU compatible No insulation with loader communication port, CT input. Functional insulation with any other input / output Loader communication (RS-C) interface standards No. of port, synchro speed Data format Protocol Connection RS-C compatible port Half-duplex, asynchronous cycle.kbps (fi xed) Data bit, no parity Modbus RTU compatible. diameter mini-plug/jack [on the front of the module] (Common cable with PXG, PXH) No insulation with RS-, CT input. Functional insulation with any other input / output

12 Control functions Control s () PID control (including FUZZY PID control)-pid constant : Set by auto tuning () PID (Heat /cool) control (including FUZZY PID control)-pid constant : Set by auto tuning Control parameter Proportional band (P) :. to.%, P=: position control ON Integration time (I): sec to sec. I= : Integration OFF Derivation time (D):. to. sec. D=: Derivation OFF Control cycle: ms Control mode larm function larm type larm output Heater break alarm No. of alarm set-points larm type Heater current alarm larm output Display, configuration Mode type: uto / Manual / Remote Mode switching: uto Manual : balance less / bump less transfer uto/manual Remote : balance/bump less transfer uto/manual Remote : balance/bump less transfer PV value (Lower/upper limit, absolute / deviation value, range) Loop burnout alarm, Error alarm, etc. (Nonexcitation, delay, latch, timer function also available) Data output via communication or output from event input / output module or points ( points/control channel) Detect when output ON (break detection) Detect when output OFF (leakage current detection) (setting can be done separately by point) Detectable current range: to Detected current resolution:. Setting resolution:. Operation dead band:. to. Data output via communication or output from event input / output module Display Status display LED ( colors x points) Display contents RUN/FULT, RS- TX/RX, OUT / ERR by loop ( loops) Setting device Rotary SW x Set contents RS- Station No. (Station No.= setting value + ) Structure Case material Polyphenylene oxide (fl ame retardant grade : ULV- equivalent) Case color Case ; red,terminal, base part ; black Protection Dimensions Weight Installation Extend terminal Body : IP grade protection (ventilation slits on the top and the bottom of the body) Terminal : IP grade protection, terminal cover is available as an option (W) (H) (D) mm (excluding terminal cover and projected part) pprox. g DIN rail mounting or mounting with M screws inside a cabinet Process value input / control output : Detachable terminal block (M screw x terminals) Power supply connection: Terminal block on the base part (M screw x terminals) Power is supplied via side connectors in the case of lateral connecting. (Max. units) RS- communication connection : Terminal block on the base part (M screw x terminals) RS- communication is connected via side connectors in the case of lateral connecting. CT input : Special connectors (pin pcs.) [on the front of the module] Loader communication port :. diameter miniplug / jack [on the front of the module] General specification Power supply Power consumption Effect of power outage Memory backup resistance block diagram Vdc±% Max..W (m) [when Vdc is applied] Outage of ms or less ; no impact Nonvolatile memory (EEPROM) No. of update ;, M or more (Vdc) Power Loader communication port RS- communication port CT Input (CT, B - CT,B) OUT (relay contact output) OUT (relay contact output) OUT (relay contact output) OUT (relay contact output) Normal operating condition mbient temperature mbient humidity Vibration Warmup time PV PV PV PV OUT (SSR drive, current) OUT (SSR drive, current) OUT (SSR drive, current) OUT (SSR drive, current) Basic insulation (VC)Functional insulation (VC)Functional insulation (VC) - to degrees C mbient temperature is the temperature underneath the * controller inside the equipment or the cabinet where the controller is installed. % RH or less (non condensing) to Hz,.m/s (G) or less min. or more Transporting, storage conditions (packing conditions) Storage temperature mbient humidity Vibration Shock - to degrees C %RH or less (no condensing) to Hz,.m/s (G) or less m/s (G) or less [Table ] Input type and standard input range Input type Resistance bulb (IEC) Input code Measurement range [degree C] Min. measurement [degree C] Ptohm to. - to. - to Thermocouple J to. to. K to. to. to R to B to S to T - to. E - to. N to PL to DC voltage DC-V - to DC-V (scaling range) DC-V DC-V

13 Event Input/Output Module Type : PUME Digital Input No. of input Input type Input rating Input judgment Input read cycle Option Digital Output No. of output Output type Option RS- interface standards No. of port, synchro speed distance Recommended cable No. of connectable units Data format Protocol points (points/common blocks) Voltage contact input, sink/source common (bidirectional) V DS,input impedance approx..kohm ON judgment: to.v DC OFF judgment: to V DC ms (min.pulse width) Functional insulation with internal circuit NOT/ND/OR logic operation, Latch action points (points/common blocks) Select from a) and b) according to model type specifi cation a) Relay contact output - Contact structure: SPST contact - Contact capacity: V C/V D, - : Functional insulation with internal circuit b) Transistor open collector (sink) output - Rating: V DC, m (Residual voltage when power is ON:.V DC or less) - : Functional insulation with internal circuit Control output/event output selection, NOT/ND/OR logic operation, Latch action RS- compatible port Two-wire, half-duplex, asynchronous cycle.k,.k,.k,.kbps km (.kbps or less), m (.kbps) KPEV-SB.sq-equivalent units (master and slave)( units if any modules other than PUM series are included in slaves.) Data bit;, parity; even / odd / none Modbus RTU compatible No insulation with loader communication port. Functional insulation with any other input/output Loader communication (RS-C) interface standards No. of port, synchro speed Data format Protocol Connection RS-C compatible port Half-duplex, asynchronous cycle.kbps (fi xed) Data bit, no parity Modbus RTU compatible. diameter mini-plug/jack [on the front of the module] (Common cable with PXG, PXH) No insulation with RS- Functional insulation with any other input/output Display, configuration Display Display contents Status display LED ( colors x points + points) RUN/FULT, RS- TX/RX, input points output points Setting device Rotary SW x [on the front of the module] Set contents RS- Station No. (Station No.= setting value + ) Structure Case material Polyphenylene oxide (fl ame retardant grade : ULV- equivalent) Case color Case ; red, Terminal, base part ; black Protection Dimensions Weight Installation External terminal Body : IP grade protection (ventilation slits on the top and the bottom of the body) Terminal : IP grade protection, terminal cover is available as an option (W) (H) (D) mm(excluding terminal cover and projected part) pprox. g General specification Power supply Power consumption Effect of power outage Memory backup resistance block diagram DIN rail mounting or mounting with M screws inside a cabinet Digital input / digital output : Detachable terminal block (M screw x terminals) Power supply connection: Terminal block on the base part (M screw x terminals) Power is supplied via side connectors in the case of lateral connecting. (Max. units) RS- communication connection : Terminal block on the base part (M screw x terminals) RS- communication is connected via side connectors in the case of lateral connecting. Loader communication port :. diameter miniplug / jack [on the front of the module] Vdc±% Max..W (m) [when Vdc is applied] Outage of ms or less ; no impact Nonvolatile memory (EEPROM) No. of update ;, M or more (Vdc) Power Di to Loader communication port Di to RS- communication port Do to Do to Normal operating condition mbient temperature mbient humidity Vibration Warmup time Functional insulation (VC) Functional insulation (VC) - to degrees C * mbient temperature is the temperature underneath the controller inside the equipment or the cabinet where the controller is installed. %RH or less (no condensing) to Hz,.m/s (G) or less min. or more Transporting, storage conditions (packing conditions) Storage temperature mbient humidity Vibration Shock - to degrees C %RH or less (no condensing) to Hz,.m/s (G) or less m/s (G) or less

14 nalog Input/Output Module Type : PUMV nalog Input No. of input Input signal Measurement range and input type Measurement accuracy (Ta= C) points Select from the group I or II depending on the model code. Group I: Thermocouple: K, J, T, E, R, B, S, N, PL-II Resistance bulb (-wire): Pt, JPt Group II : DC voltage, current DC to V, DC to V, DC to V, DC to V DC to m, DC to m " The power current input is external in ohm resistance. It's input of DC to V or DC to V Range. See table Thermocouple input: : ±.%FS±digit± degree C or ± degrees C whichever is greater *Unless B thermocouple to degrees C : ±%FS±digit± degree C R thermocouple to degrees C : ±%FS±digit± degree C T thermocouple - to degree C : ±.%FS±digit± degree C Resistance bulb input : ±.%FS±digit or ± degree C whichever is greater Voltage input : ±.%FS±digit Resolution See table Temperature ±.%FS/ degrees C fl uctuation Input sampling ms cycle Input impedance Thermocouple: M ohm or more Current input : ohm Voltage input : approx. M ohm Infl uence of signal source resistance llowable wiring resistance llowable input voltage Noise rejection ratio Input compensation Over range, under range nalog Output No. of output Output type ctual output range ccuracy Linearity Resolution Ripple current Loading resistance Thermocouple: ±.%FS±digit / ohm Voltage input : ±.%FS±digit / ohm Resistance bulb input: ohm or less (per wire) DC voltage input: within ±V Current input: within ±m Thermocouple/resistance bulb: within ±V Normal mode: db or more (/Hz) Common mode: db or more (/Hz) between earth, power supply, output Vac, /Hz a) User adjustment: zero point, span point ±%FS b) PV shift: ±%FS c) First order lag fi lter :. to. sec. (Filter off when setting is.) Out of range of - to %FS (ccuracy cannot be ensured for - to, to %FS) Functional insulation between channels, and with any other input/output points Current output DC to m, DC to m DC m to.m ±.%FS (less than m : ±%FS) ±.%FS (less than m : ±%FS), or more P-P.m or less ohm or less No insulation with any other output Function insulation with others (power supply, analog input, RS communication, and loader port) than those above RS- interface standards No. of port, synchro speed distance Recommended cable No. of connectable units Data format Protocol RS- compatible port Two-wire, half-duplex, asynchronous cycle.k,.k,.k,.kbps km (.kbps or less), m (.kbps) KPEV-SB.sq-equivalent units (master and slave)( units if any modules other than PUM series are included in slaves.) Data bit;, parity; even / odd / none Modbus RTU compatible No insulation with loader communication port, Functional insulation with any other input / output Loader communication (RS-C) interface standards No. of port, synchro speed Data format Protocol Connection RS-C compatible port Half-duplex, asynchronous cycle.kbps (fi xed) Data bit, no parity Display, configuration Modbus RTU compatible. diameter mini-plug/jack [on the front of the module] (Common cable with PXG, PXH) No insulation with RS-, Functional insulation with any other input / output Display Status display LED ( colors x points) Display contents RUN/FULT, RS- TX/RX, OUT / ERR by loop ( loops) Setting device Rotary SW x Set contents RS- Station No. (Station No.= setting value + ) Structure Case material Polyphenylene oxide (fl ame retardant grade : ULV- equivalent) Case color Case ; red, Terminal, base part ; black Protection Dimensions Weight Installation External terminal Body : IP grade protection (ventilation slits on the top and the bottom of the body) Terminal : IP grade protection, terminal cover is available as an option (W) (H) (D) mm (excluding terminal cover) pprox. g DIN rail mounting or mounting with M screws inside a cabinet Process value input / control output : Detachable terminal block (M screw x terminals) Power supply connection: Terminal block on the base part (M screw x terminals) Power is supplied via side connectors in the case of lateral connecting. (Max. units) RS- communication connection : Terminal block on the base part (M screw x terminals) RS- communication is connected via side connectors in the case of lateral connecting. Loader communication port :. diameter miniplug / jack [on the front of the module]

15 General specification Power supply Vdc±% Power Max..W (m) [when Vdc is applied] consumption Effect of power Outage of ms or less ; no impact outage Memory backup Nonvolatile memory (EEPROM) No. of update ;, M or more (Vdc) resistance block diagram Power Loader communication port RS- communication port PV PV PV PV OUT (current) OUT (current) OUT (current) OUT (current) Functional insulation (VC) Functional insulation (VC) Normal operating condition mbient temperature mbient humidity Vibration Shock Warmup time - to degrees C * mbient temperature is the temperature underneath the controller inside the equipment or the cabinet where the controller is installed. %RH or less (no condensing) to Hz,.m/s (G) or less m/s (G) or less min. or more Transporting, storage conditions (packing conditions) Storage temperature mbient humidity Vibration Shock - to degrees C %RH or less (no condensing) to Hz,.m/s (G) or less m/s (G) or less

16 nalog Input Module Type : PUMN nalog Input No. of input Input signal Measurement range and input type Measurement accuracy (Ta= C) points Select from group I or II on the model code. Group I: Thermocouple: K, J, T, E, R, B, S, N, PL-II Resistance bulb (-wire) : Pt, JPt Group II : DC voltage, current DC to V, DC to V, DC to V, DC to V DC to m, DC to m " The power current input is external in ohm resistance. It's input of DC to V or DC to V Range. See table Thermocouple input: : ±.%FS±digit± degree C or ± degrees C whichever is greater *Unless B thermocouple to degrees C : ±%FS±digit± degree C R thermocouple to degrees C : ±%FS±digit± degree C T thermocouple - to degree C : ±.%FS±digit± degree C Resistance bulb input : ±.%FS±digit or ± degree C whichever is greater Voltage input : ±.%FS±digit Resolution See table Temperature ±.%FS/ degrees C fl uctuation Input sampling ms cycle Input impedance Thermocouple: M ohm or more Current input : ohm Voltage input : approx. M ohm Infl uence of signal source resistance llowable wiring resistance llowable input voltage Noise rejection ratio Input compensation Over range, under range RS- interface standards No. of port, synchro speed distance Recommended cable No. of connectable units Data format Protocol Thermocouple: ±.%FS±digit / ohm Voltage input : ±.%FS±digit / ohm Resistance bulb input: ohm or less (per wire) DC voltage input: within ±V Current input: within ±m Thermocouple/resistance bulb: within ±V Normal mode: db or more (/Hz) Common mode: db or more (/Hz) between process value input and earth ground, power supply, output Vac, /Hz a) User adjustment: zero point, span point ±%FS b) PV shift: ±%FS c) First order lag fi lter :. to. sec. (fi lter off when setting is.) Out of range of - to %FS (ccuracy cannot be ensured for - to, to %FS) Functional insulation between channels, and with any other input/output RS- compatible port Two-wire, half-duplex, asynchronous cycle.k,.k,.k,.kbps km (.kbps or less), m (.kbps) KPEV-SB.sq-equivalent units (master and slave)( units if any modules other than PUM series are included in slaves.) Data bit;, parity; even / odd / none Modbus RTU compatible No insulation with loader communication port Functional insulation with any other input/output Loader communication (RS-C) interface standards No. of port, synchro speed Data format Protocol Connection RS-C compatible port Half-duplex, asynchronous cycle.kbps (fi xed) Data bit, no parity Display, configuration Display Display contents Modbus RTU compatible. diameter mini-plug/jack [on the front of the module] (Common cable with PXG, PXH) No insulation with RS- Functional insulation with any other input/output Status display LED ( colors x points + points) RUN/FULT, RS- TX/RX, Input ERR/Output by loop Setting device Rotary SW x Set contents RS- Station No. (Station No.= setting value + ) Structure Case material Polyphenylene oxide (fl ame retardant grade : ULV- equivalent) Case color Case ; red, Terminal, base part ; black Protection Dimensions Weight Installation External terminal Body : IP grade protection (ventilation slits on the top and the bottom of the body) Terminal : IP grade protection, terminal cover is available as an option (W) (H) (D) mm (excluding terminal cover) pprox. g General specification Power supply Power consumption Effect of power outage Memory backup resistance block diagram DIN rail mounting or mounting with M screws inside a cabinet Process value input / control output : Detachable terminal block (M screw x terminals) Power supply connection: Terminal block on the base part (M screw x terminals) Power is supplied via side connectors in the case of lateral connecting. (Max. units) RS- communication connection : Terminal block on the base part (M screw x terminals) RS- communication is connected via side connectors in the case of lateral connecting. Loader communication port :. diameter miniplug / jack [on the front of the module]" Vdc±% Max..W (m) [when Vdc is applied] Outage of ms or less ; no impact Nonvolatile memory (EEPROM) No. of update ;, M or more (Vdc) Power Loader communication port RS- communication port PV PV PV PV Functional insulation (VC) Functional insulation (VC)

17 Normal operating condition mbient temperature mbient humidity Vibration Warmup time - to degrees C * mbient temperature is the temperature underneath the controller inside the equipment or the cabinet where the controller is installed. %RH or less (no condensing) to Hz,.m/s (G) or less min. or more Transporting, storage conditions (packing conditions) Storage temperature mbient humidity Vibration Shock - to degrees C %RH or less (no condensing) to Hz,.m/s (G) or less m/s (G) or less

18 nalog Output Module Type : PUMT nalog Output No. of output Output type ctual output range ccuracy Linearity Resolution Ripple current Loading resistance RS- interface standards No. of port, synchro speed distance Recommended cable No. of connectable units Data format Protocol points Current output DC to m, DC to m DC m to.m ±.%FS (less than m : ±%FS) ±.%FS (less than m : ±%FS), or more P-P.m or less ohm or less No insulation with any other output Functional insulation with others (power source, analog input, RS communication and loader port) than those above RS- compatible port Two-wire, half-duplex, asynchronous cycle.k,.k,.k,.kbps km (.kbps or less), m (.kbps) KPEV-SB.sq-equivalent units (master and slave)( units if any modules other than PUM series are included in slaves.) Data bit;, parity; even / odd / none Modbus RTU compatible No insulation with loader communication port Functional insulation with any other input/output Loader communication (RS-C) interface standards No. of port, synchro speed Data format Protocol Connection RS-C compatible port Half-duplex, asynchronous cycle.kbps (fi xed) Data bit, no parity Display, configuration Display Display contents Modbus RTU compatible. diameter mini-plug/jack [on the front of the module] (Common cable with PXG, PXH) No insulation with RS Functional insulation with any other input/output Status display LED ( colors x points + points) RUN/FULT, RS- TX/RX, Input ERR/Output by loop Setting device Rotary SW x Set contents RS- Station No. (Station No.= setting value + ) Structure Case material Polyphenylene oxide (fl ame retardant grade : ULV- equivalent) Case color Case ; red, Terminal, base part ; black Protection Dimensions Weight Installation External terminal Body : IP grade protection (ventilation slits on the top and the bottom of the body) Terminal : IP grade protection, terminal cover is available as an option (W) (H) (D) mm (excluding terminal cover) pprox. g General specification Power supply Power consumption Effect of power outage Memory backup resistance block diagram DIN rail mounting or mounting with M screws inside a cabinet Process value input / control output : Detachable terminal block (M screw x terminals) Power supply connection: Terminal block on the base part (M screw x terminals) Power is supplied via side connectors in the case of lateral connecting. (Max. units) RS- communication connection : Terminal block on the base part (M screw x terminals) RS- communication is connected via side connectors in the case of lateral connecting. Loader communication port :. diameter miniplug / jack [on the front of the module]" Vdc±% Max..W (m) [when Vdc is applied] Outage of ms or less ; no impact Nonvolatile memory (EEPROM) No. of update ;, M or more (Vdc) Normal operating condition mbient temperature mbient humidity Vibration Warmup time Power OUT (current) Loader communication port OUT (current) RS- communication port OUT (current) OUT (current) Functional insulation (VC) Functional insulation (VC) - to degrees C * mbient temperature is the temperature underneath the controller inside the equipment or the cabinet where the controller is installed. %RH or less (no condensing) to Hz,.m/s (G) or less min. or more Transporting, storage conditions (packing conditions) Storage temperature mbient humidity Vibration Shock - to degrees C %RH or less (no condensing) to Hz,.m/s (G) or less m/s (G) or less

19 CC-Link Module Type:PUMCL CC-Link Version CC-Link Ver../. Kind of device Remote device speed or distance Shared units/ Station numbers for communication data length speed Total extension distance kbps kbps.mbps Mbps m or m or less less m or less m or less Mbps m or less Refer to the CC-Link Cable Wiring manual (issued by CC-Link partner association) about details Shared stations / providing number to Shared stations/ Remote I/O extended cyclic (RX/RY) Remote Register (RWr/RWw) Control Module PUM stations Each bit word or units stations Each bit word or units stations Each bit word or units Connection cable CC-Link original cable for version. Connection Detachable terminal block (M screw) Terminating External type ( ohm, /W) resister Loader communication (RS-C) interface standards No. of port, synchro speed Data format Protocol Connection RS-C compatible port Half-duplex, asynchronous cycle.kbps (fi xed) Data bit, no parity Display, configuration Display Display contents Setting device or Set contents Modbus RTU compatible. diameter mini-plug/jack [on the front of the module] (Common cable with PXG, PXH) Functional insulation with any other input/output Status display LED ( colors x points + points) RUN/FULT Control Module Connection status (TX/RX) CC-Link status (L.RUN, L.ERR, SD, RD) Setting device Set contents Front Rotary SW CC-Link Setting Station numbers Equipment interior Rotary SW Dip SW (bit) CC-Link Setting speed CC-Link Setting mode Structure Case material Polyphenylene oxide (fl ame retardant grade : ULV- equivalent) Case color Case ; red,terminal, base part ; black Protection Dimensions Weight Installation External terminal Body : IP grade protection (ventilation slits on the top and the bottom of the body) Terminal : IP grade protection, terminal cover is available as an option (W) (H) (D) mm (excluding terminal cover) pprox. g General specification Power supply Power consumption Effect of power outage Memory backup resistance block diagram DIN rail mounting or mounting with M screws inside a cabinet CC-Link communication terminal: Detachable terminal block (M screw x terminals) Power supply connection: Terminal block on the base part (M screw x terminals) Power is supplied via side connectors in the case of lateral connecting. (Max. units) Loader communication port :. diameter miniplug / jack [on the front of the module]" Vdc±% Max.. W( m) [when Vdc is applied] Outage of ms or less ; no impact Nonvolatile memory (EEPROM) No. of update ;, M or more (Vdc) Normal operating condition mbient temperature mbient humidity Vibration Warmup time Power SLD/FG terminal (CC-Link connecting terminal) Loader communication port CC-Link communication Basic insulation (VC)Functional insulation (VC)Functional insulation (VC) - to degrees C * mbient temperature is the temperature underneath the controller inside the equipment or the cabinet where the controller is installed. %RH or less (no condensing) to Hz,.m/s (G) or less min. or more Transporting, storage conditions (packing conditions) Storage temperature mbient humidity Vibration Shock - to degrees C %RH or less (no condensing) to Hz,.m/s (G) or less m/s (G) or less

20 Mitsubishi PLC program less communication Module Type:PUMCM RS- / RS communication standards No. of port, synchro speed distance Recommended cable Data format RS-/RS compatible port RS- interface; -wire, half-duplex, asynchronous cycle RS- interface; -wire, half duplex, asynchronous cycle.k,.k,.k,.k,.k,.kbps MELSEC-Q series m or less MELSEC- series m or less MELSEC-FX series m or less KFPEV-SBP.sq /FUJI ELECTRIC CBLE CO., LTD Start bit, Data bit; parity; even/odd/none Stop bit Protocol MC protocol (type,, ) No insulation with any communication interface other than loader interface, Functional insulation with loader communication interface and other all signals Function MELSEC-Q//nS/FX series of PLC and program less communication :N Connection Usable PLC is MELSEC-Q//nS series. Confi guration by using FX series is not possible. RS-C communication standards No. of port, synchro speed Data format RS-C compatible port Half-duplex, asynchronous cycle.k,.k,.k,.k,.k,.kbps Start bit, Data bit; parity; even/odd/none Stop bit Protocol MC protocol(type,, ) No insulation with any communication interface other than loader communication interface, Functional insulation with loader communication interface and other all signals Function MELSEC-Q//nS/FX series of PLC and program less communication :N Connection Unusable Loader communication (RS-C) interface standards No. of port, synchro speed Data format Protocol Connection RS-C compatible port Half-duplex, asynchronous cycle.kbps (fi xed) Display, configuration Display Display contents Setting device and setting contents Data bit, no parity Modbus RTU compatible. diameter mini-plug/jack [on the front of the module] (Common cable with PXG, PXH) Functional insulation with any other signals Status display LED ( colors x points + points) RUN/FULT,internal communication status TX/RX (Port), TX/RX (Port) Setting device Setting contents Front face Rotary SW x Programless communication station setting Within the device DIP SW (bit) x RS-C/RS-/RS Opetarion mode Setting Communicable combination of MC protocol and MC protocol frame type Structure object I/F Qn compatible C frame compatible C frame Type Type Type Q series RS-C RS- RS- series RS-C RS- RS- FX series RS-C RS- : : connection + :N connection is available : : connection is available : ny connection are not available When using :N connection, the settings of every connected programless communication modules should be the same. Case material Polyphenylene oxide (fl ame retardant grade : ULV- equivalent) Case color Case ; red,terminal, base part ; black Protection Body : IP grade protection (ventilation slits on the top and the bottom of the body) Terminal : IP grade protection, terminal cover is available as an option Dimensions (W) (H) (D) mm (excluding terminal cover) Weight pprox. g Installation DIN rail mounting or mounting with M screws inside a cabinet External terminal Programless communication interface: Detachable terminal block (M screw x terminals) Power supply connection: Terminal block on the base part (M screw x terminals) Power is supplied via side connectors in the case of lateral connecting. (Max. units) Loader communication port :. diameter miniplug / jack [on the front of the module]" General specification Power supply Vdc±% Power consumption Max..W (m) [when Vdc is applied] Effect of power Outage of ms or less ; no impact outage Memory backup Nonvolatile memory (EEPROM) No. of update ;, M or more (Vdc) resistance block Power RS-C diagram Loader communication port RS- RS- = Functional insulation (VC) - Functional insulation (VC) Normal operating condition mbient - to degrees C temperature * mbient temperature is the temperature underneath the controller inside the equipment or the cabinet where the controller is installed. mbient humidity %RH or less (no condensing) Vibration to Hz,.m/s (G) or less Warmup time min. or more Transporting, storage conditions (packing conditions) Storage temperature - to degrees C mbient humidity %RH or less (no condensing) Vibration to Hz,.m/s (G) or less Shock m/s (G) or less

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series Programmable Terminal NPSeries Easy Setup with the Low-cost, Compact NP Series Simpler and More Versatile.OMRON s Compact NP Series Connect! Easier connection to OMRON PLCs and Temperature Controllers,

More information

2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode:

2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode: COMMUNICATION INSTRUCTION MANUAL TEMPERATURE CONTROLLER KT4, KT8 and KT9 No.KTC1E6 2009.05 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.

More information

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference : 9010709-03

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference : 9010709-03 MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE USER GUIDE Document reference : 9010709-03 If you have questions about the MDM192 or desire assistance, contact ETIC TELECOMMUNICATIONS at the following

More information

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C F4 Process Controller Installation and Operation Guide SAFETY ALERTS The symbols below are used on the equipment and throughout this document to draw the user s attention to important operational and safety

More information

ZC-24DO CANopen I/O Module: 24 Digital Outputs

ZC-24DO CANopen I/O Module: 24 Digital Outputs Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches

More information

ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION

ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is

More information

Application/Connection Examples

Application/Connection Examples This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.

More information

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature

More information

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES Auto-tune PID Temperature Controller FEATURES Easy-to-use Fuzzy modified PID heat & cool control Fast A-D sampling rate (5 times/s) Universal input (PT100, thermocouple) with high accuracy 18-bit A-D Analog

More information

Programmable Relays. ZEN Series. ZEN Programmable Relays. Applications

Programmable Relays. ZEN Series. ZEN Programmable Relays. Applications Programmable Relays ZEN Series Relay, Timer, Counter, and Time Switch Functions Weekly Timer and Calendar Timer Functions Twin Timer Function (Separate ON/OFF Times) Two Analog Input Channels (DC Models

More information

M2M/IoT Solutions. www.contec.com

M2M/IoT Solutions. www.contec.com M2M/IoT Solutions www.contec.com M2M/IoT Solutions TM Hardware Highly Reliable M2M Controllers for Various Solutions M2M Controllers Compact design available on DIN rails Low-power design using a CPU tailored

More information

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master

More information

Communication Ethernet (10Base-T) is available. (option)

Communication Ethernet (10Base-T) is available. (option) Type: PHF Long Term Record Data Saving 4years in Compact Flash (In case of using 512MB Compact Flash) Saved Data playback Saved data in Memory card can be easily called out and played back on display (1Base-T)

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

Industrial Bar Code Scanners

Industrial Bar Code Scanners DX8200A Industrial Bar Code Scanners Configuration SW Tool ACR4 technology PackTrack ASTRA technology APPLICATIONS Postal/Courier parcel sorting and tracking Automated warehousing identification systems

More information

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com This handbook has been designed as a guide to the installation and operation of King Pigeon Hi-Tech.Co.,Ltd DAM series. Statements

More information

Monitor and control the sensors through network. supported OPTEX FA CO., LTD. Remote controlling of fiber sensors. Reduces wires and saves space

Monitor and control the sensors through network. supported OPTEX FA CO., LTD. Remote controlling of fiber sensors. Reduces wires and saves space CC-Link Communication Unit * FASTUS is a product brand of Optex FA. Monitor and control the sensors through network supported Remote controlling of fiber sensors Reduces wires and saves space OPTEX FA

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

Industrial Bar Code Scanners

Industrial Bar Code Scanners DS4800 Industrial Bar Code Scanners Enhanced Connectivity Ease of use Configuration SW Tool ACR4 technology Smart focus adjustment APPLICATIONS Automated warehousing Reading on pallets Picking systems

More information

User manual Compact Web PLC WP240 series IEC-line

User manual Compact Web PLC WP240 series IEC-line User manual Compact Web PLC WP240 series IEC-line update: 09-01-2014 IEC-line by OVERDIGIT overdigit.com 1. General description The WP240 device is a PLC, programmable in IEC61131-3 language using CoDeSys

More information

Multifunction devices

Multifunction devices devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2

More information

g9sp Programmable Safety controllers compact Stand-Alone Programmable controller NEW! example of System configuration G9SP

g9sp Programmable Safety controllers compact Stand-Alone Programmable controller NEW! example of System configuration G9SP Programmable Safety controllers g9sp G9SP compact Stand-Alone Programmable controller Stand-alone safety controller for small and mid-sized machinery Easy programming for complex safety control Three types

More information

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual DVPPF02-H2 PROFIBUS DP Slave Communication Module Application Manual Warning Please read this instruction carefully before use and follow this instruction to operate the device in order to prevent damages

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

Modbus Server SAMSUNG Air Conditioners

Modbus Server SAMSUNG Air Conditioners IntesisBox Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung Air Conditioning Systems from any master device TCP or RTU (BMS, PLC, SCADA, HMI, TouchPanel ) Master TCP Master

More information

User Manual. cmt-svr Startup Guide

User Manual. cmt-svr Startup Guide User Manual cmt-svr Startup Guide Table of Contents Chapter 1 Overview... 1 1.1 Specification... 1 1.2 Dimensions... 2 1.3 Connector pin designations... 3 1.4 USB host port and SD card slot... 3 1.5 Ethernet

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

IntesisBox KNX Modbus RTU master

IntesisBox KNX Modbus RTU master IntesisBox KNX RTU master Gateway for integration of RTU devices into KNX control systems. Integrate RTU devices (Chillers, Roof Tops, electricity meters, heating floors, heat pumps, PLCs ) into KNX control

More information

User Guide Reflow Toaster Oven Controller

User Guide Reflow Toaster Oven Controller User Guide Reflow Toaster Oven Controller Version 1.5-01/10/12 DROTEK Web shop: www.drotek.fr SOMMAIRE 1. Introduction... 3 2. Preparation of THE REFLOW CONTROLLER... 4 2.1. Power supply... 4 2.2. USB

More information

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053. PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection

More information

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy

More information

Industrial Bar Code Scanners

Industrial Bar Code Scanners DS6400 Industrial Bar Code Scanners Configuration SW Tool ACR4 technology PackTrack APPLICATIONS Automated warehousing Medium conveyor sorting Reading on forklift trucks Picking systems Automated shop

More information

USB to RS-232/422/485 Isolated Converter. Quatech Model SSU2-400I Operation Manual

USB to RS-232/422/485 Isolated Converter. Quatech Model SSU2-400I Operation Manual USB to RS-232/422/485 Isolated Converter Quatech Model SSU2-400I Operation Manual First Edition, Jun 2008 1 Table of Contents 1. Introduction 2 2. Package checklist 3 3. Product Specification 4 4. Product

More information

EA7-T8C EA7-T10C EA7-T12C EA7-T15C

EA7-T8C EA7-T10C EA7-T12C EA7-T15C The new Generation of Touch Panels with ambitious image presentation and integrated operating function With the C-more series, featuring STN and TFT touch screens, AutomationDirect now provides the best

More information

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.

More information

Series Digital Controller Instruction Sheet

Series Digital Controller Instruction Sheet 213/1/2 Series Digital Controller Instruction Sheet Thank you very much for purchasing DELTA DTC Series Temperature Controller. Please read this instruction sheet before using your DTC series to ensure

More information

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide 2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide 1. Introduction Thank you for purchasing this 2-Port RS232/422/485 Combo Serial to USB Adapter.

More information

MANUAL FOR RX700 LR and NR

MANUAL FOR RX700 LR and NR MANUAL FOR RX700 LR and NR 2013, November 11 Revision/ updates Date, updates, and person Revision 1.2 03-12-2013, By Patrick M Affected pages, ETC ALL Content Revision/ updates... 1 Preface... 2 Technical

More information

IntesisBox Modbus Server Fidelio IP

IntesisBox Modbus Server Fidelio IP IntesisBox Server Fidelio IP Gateway for integration of Micros Fidelio Ho management system into (RTU and TCP) enabled control systems. Integrate your Micros Fidelio Ho management system into your master

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8 CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps LEDs for display of supply voltage, group and bus errors as well as status and diagnostics Connection

More information

Microprocessor-Controlled Multi-Channel Temperature Controller D4 INSTRUCTION MANUAL

Microprocessor-Controlled Multi-Channel Temperature Controller D4 INSTRUCTION MANUAL Microprocessor-Controlled Multi-Channel Temperature Controller D4 INSTRUCTION MANUAL Table of Contents 1 Introduction... 1 2 Features... 1 3 Order Code... 2 4 Package and Storage... 2 5 Mechanical Installation...

More information

IntesisBox Modbus Server SAMSUNG Air Conditioners

IntesisBox Modbus Server SAMSUNG Air Conditioners IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection

More information

EDI Distributor Control Interface Wiring and Setup Instructions

EDI Distributor Control Interface Wiring and Setup Instructions Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls

More information

MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!

MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise! Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount

More information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual 5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...

More information

User Manual IC-485AI 2002-09-27

User Manual IC-485AI 2002-09-27 User Manual IC-485AI Note: This equipment has been tested and found to comply ith the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable

More information

IntesisBox KNX LG Air Conditioning

IntesisBox KNX LG Air Conditioning IntesisBox KNX LG Air Conditioning Gateway for integration of LG Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB) bus. Direct connection to LG outdoor unit

More information

+ A + + - B V B - - + + + NO NC V COM - - - PV PV

+ A + + - B V B - - + + + NO NC V COM - - - PV PV + - A + B B - V + - NO NC COM + - + - V + - PV PV Ramp Soak 100 70 50 30 3 5 3 8 5 3 Minute Steam Heating Sensor Cooling Water PID Hotplate Specifications Input power supply AC 100 to 240V, 50/60Hz, DC

More information

TO-PASS. TO-PASS -FAQ- Remote Monitoring. What is TO-PASS used for? What are the special functions of TO-PASS?

TO-PASS. TO-PASS -FAQ- Remote Monitoring. What is TO-PASS used for? What are the special functions of TO-PASS? TO-PASS -FAQ- Remote Monitoring What is TO-PASS used for? TO-PASS modules are used as/for: Permanent online connection Fault detectors Remote data polling Data storage Telecontrol module What are the special

More information

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012 Technical Information THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012 GENERAL DESCRIPTION THYRISTORS T1-1PH is a full digital and universal

More information

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE Local Area Networks (LAN) Servers Data centers Internet centers (ISP/ASP/POP) Industrial PLCs EPOS (Electronic Point of Sale) Systems Emergency devices (lights/alarms) Electro-medical devices Telecommunication

More information

COM. port RS232C RS232C RS232C RS485. Thermocouple input. Part number. Not available. Not available. Available. Not available Available RS485.

COM. port RS232C RS232C RS232C RS485. Thermocouple input. Part number. Not available. Not available. Available. Not available Available RS485. Control Unit New Born! Advanced PC! Timer, Counter, Hour meter, Temperature Controller and PC in a Unit Features. 5-character, -line, -color Display Simple characters and numerical values can be displayed.

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

Model: DC-A2IO Advanced HVAC Controller

Model: DC-A2IO Advanced HVAC Controller Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA

More information

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter ICS-2 S15 Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter Cost Effective Solution for RS-232 / RS-422 / RS-485 to Industrial Ethernet Application PLANET ICS-210x series Smart Media Converter

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,

More information

s!nus-elektrotechnikai bt. Industrial IT & Automation

s!nus-elektrotechnikai bt. Industrial IT & Automation USB/PPI+ Optoelectronic isolated USB/PPI adapter Optoelectronic isolated USB/PPI adapter, can replace Siemens 6ES7 901-3DB30-0XA0, the largest communication distance of up to 2 kilometers. Not support

More information

IntesisBox Modbus Server - Mitsubishi Electric G50

IntesisBox Modbus Server - Mitsubishi Electric G50 IntesisBox Server - Mitsubishi Electric G50 Gateway for monitor and control Mitsubishi Electric City Multi Air Conditioning systems from any master device TCP or RTU (BMS, PLC, SCADA, HMI, TouchPanel )

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.

More information

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male

More information

1 Serial RS232 to Ethernet Adapter Installation Guide

1 Serial RS232 to Ethernet Adapter Installation Guide Installation Guide 10/100 Mbps LED (amber color ) Link/Activity LED (green color ) 1. Introduction Thank you for purchasing this 1-port RS232 to Ethernet Adapter (hereinafter referred to as Adapter ).

More information

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A 6ES7313-5BF03-0AB0 Page 1 Product data sheet 6ES7313-5BF03-0AB0 SIMATIC S7-300, CPU 313C, COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO 1 PT100, 3 FAST COUNTERS (30 KHZ), INTEGRATED 24V DC POWER SUPPLY,

More information

IntesisBox KNX Modbus TCP master

IntesisBox KNX Modbus TCP master IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration

More information

Optimize your simple machines... Modicon M218 Selection Guide

Optimize your simple machines... Modicon M218 Selection Guide Optimize your simple machines... Modicon M218 Selection Guide Compact Solution for Simple Machines Optimized Logic Controller Modicon M218 With intelligent software platform, specialized functional s,

More information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data. 425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and

More information

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485. IntesisBox KNX SAMSUNG Air Conditioning Gateway for integration of Samsung air conditioners into KNX control systems. Integrate Samsung Air Conditioners into KNX. KNX EIB Bus IntesisBox RS485 MIM-B13x/B04A

More information

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.

More information

applicomio Profibus-DP

applicomio Profibus-DP BradCommunications Profibus-DP network interface cards allow deterministic I/O data acquisition for PC-based control applications. Features New! Support of Windows 32-bit and 64-bit (WoW64) Support of

More information

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.

More information

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES SED-635 Digital Excitation System SED-635 is a complete excitation system capable of adapting to control synchronous generators of any size. The integration of the TOUCH SCREEN operator interface and a

More information

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE Technical Teaching Equipment Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE EDIBON SCADA System Teaching Technique used 4 5 2 Data Acquisition Board Cables and

More information

CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC

CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules

More information

Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual

Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual Ⅰ. Warn Warning of connection Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual If the controller fails to operate or error occurs, the system will bring fault for it, please

More information

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions

More information

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info RS232C < - > RS485 CONVERTER S MANUAL Model: LD15U INTRODUCTION Milestone s model LD-15U is a RS232 to RS 485 converter is designed for highspeed data transmission between computer system and or peripherals

More information

Replacement Guidance

Replacement Guidance Replacement Guidance [V7 Series] NEW Convert V7 Series V8 Series - List of V7 Series Models Following is a list of models in V7 series. Please check the model of V7 series unit in use and then refer to

More information

IQ151 CONTROLLER DATA SHEET

IQ151 CONTROLLER DATA SHEET IQ151 CONTROLLER DATA SHEET The IQ151 is a controller in the Trend range with 64 inputs and 32 outputs. Full DDC (direct digital control) with PID control loops is provided. The output channels may be

More information

SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program Preface Contents SIMATIC NET CP 243-2 AS-Interface Master Manual Technical Description and Installation Instructions Interface to the User Program 2 in the S7-200 CPU Access to the Data of the AS-i Slaves

More information

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 1. Introduction Thank you for purchasing this 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter. It is an

More information

ABB RTU560A Series CMU & Modules

ABB RTU560A Series CMU & Modules ABB RTU560A Series CMU & Modules 1KGT 150 648 V1.02 March 4, 2012 Slide 1 Contents RTU560A rack solutions March 4, 2012 Slide 2 560CSR01 Available for wall mounting and swing frame Supports redundant power

More information

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution

More information

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue

More information

The E5CN provides communications or event input functionality when mounted with one of the following Option Boards.

The E5CN provides communications or event input functionality when mounted with one of the following Option Boards. Digital Temperature Controller Compact and Intelligent Temperature Controller Auto-tuning and self-tuning available. Can auto-tune even during execution of self-tuning Heating or heating/cooling control

More information

Open Field Network CC-Link Troubleshooting Guide

Open Field Network CC-Link Troubleshooting Guide 2006 Mar Open Field etwork CC-Link Troubleshooting Guide Mitsubishi Electric Corporation agoya Works is a factory certified for ISO14001 (standards for environmental management systems) and ISO9001 (standards

More information

5-port 10/100Base-TX Industrial Switch (314500) User s Guide

5-port 10/100Base-TX Industrial Switch (314500) User s Guide 5-port 10/100Base-TX Industrial Switch (314500) User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by

More information

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable Designed for use with the COMbricks SALT repeater All baudrates Redundant

More information

40.3. Control Relays and Timers

40.3. Control Relays and Timers .3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

USER MANUAL. Longo programmable controller LPC-2.C05 module. Version 4

USER MANUAL. Longo programmable controller LPC-2.C05 module. Version 4 USER MANUAL Longo programmable controller LPC-2.C05 module Version 4 SMARTEH d.o.o. / Trg tigrovcev 1 / 5220 Tolmin / Slovenia / Tel.: +386(0) 388 44 00 / e-mail: info@smarteh.si / www.smarteh.si Written

More information

EVAL-UFDC-1/UFDC-1M-16

EVAL-UFDC-1/UFDC-1M-16 Evaluation Board for Universal Frequency-to- Digital Converters UFDC-1 and UFDC-1M-16 EVAL-UFDC-1/UFDC-1M-16 FEATURES Full-Featured Evaluation Board for the Universal Frequency-to-Digital Converters UFDC-1

More information

I STAR COMPUTER CO., LTD

I STAR COMPUTER CO., LTD I STAR COMPUTER CO., LTD Mini Redundant Power Supply 300W+300W for IPC-Computer Model No. TC-300R8 Table of content 1. Introduction...1 2. Specification 2.1 Input Voltage...1 2.2 DC Output...1 2.3 PS-ON

More information