DEVELOPMENT OF AN ONLINE PREDICTIVE MONITORING SYSTEM FOR POWER GENERATING PLANTS
|
|
- Avis Martin
- 8 years ago
- Views:
Transcription
1 DEVELOPMENT OF AN ONLINE PREDICTIVE MONITORING SYSTEM FOR POWER GENERATING PLANTS Randall Bickford Expert Microsystems, Inc. Orangevale, California Richard Rusaw South Carolina Electric and Gas Jenkinsville, South Carolina Eddie Davis Edan Engineering Corporation Vancouver, Washington Dr. Ramesh Shankar Electric Power Research Institute Charlotte, North Carolina KEYWORDS Condition monitoring, diagnostic monitoring, signal validation, sensor calibration, industrial automation, process control, process surveillance, smart systems ABSTRACT To assure the continued safe, reliable and efficient operation of a nuclear power plant, it is essential that accurate online measurement information is available to the plant operators, engineering and maintenance personnel. This paper describes new online signal validation and predictive condition monitoring software that uses innovative artificial intelligence techniques to detect instrument degradation and perform system diagnostics with higher accuracy and faster response time than prior art techniques. The software uses a statistical modeling technique to learn a high fidelity model of an asset, such as a process or set of equipment, from a sample of its normal operating data. Once built, the model provides an accurate estimate for each observed signal given a new data observation from the asset. Each estimated or virtual signal is compared to its actual signal counterpart using a highly sensitive fault detection procedure to statistically determine whether the actual signal agrees with the learned model. Online signal validation is applicable to power plant monitoring and control systems where time-critical safety or control functions depend on sensor input, or unexpected process interruptions due to sensor and equipment failures or false alarms are unsafe or uneconomical. Online signal validation improves process quality and efficiency by ensuring that closed loop control is performed using good sensor data. Online signal validation increases system availability and decreases system maintenance cost by optimizing performance and enabling instrumentation calibration and equipment maintenance using condition based criteria rather than time-in-service criteria. 1
2 In this paper, we discuss the Multivariate State Estimation Technique (MSET) and associated fault detection algorithms used to perform online signal validation and predictive condition monitoring. Application examples and benefits of online monitoring for nuclear power plant surveillance systems are presented. Current capabilities and planned enhancements to the algorithms and software are discussed. INTRODUCTION Expert Microsystems has developed the SureSense Multivariate State Estimation Studio signal validation software [1] to meet the unique and specific needs of the electric power-generating industry. The software ensures measurement signal integrity and thereby improves operating performance, reduces downtime, and can lower operating and maintenance cost for a wide variety of powergenerating applications. MSET was originally developed by Argonne National Laboratory for nuclear power applications where plant downtime can cost utilities and their constituents on the order of $1- million a day. MSET is a statistical modeling technique that learns a high fidelity model of an asset from a sample of its normal operating data. Once built, the software model provides an accurate estimate for each observed signal given a new data observation from the asset. Each estimated signal is compared to its actual signal counterpart using a highly sensitive fault detection procedure to statistically determine whether the actual signal agrees with the learned model or alternatively is indicative of a process anomaly, sensor data quality problem, or equipment problem. Over the last two years, MSET technology has been the subject of several successful trials using actual nuclear power plant data. These trials culminated in the July 2000 release by the U.S. Nuclear Regulatory Commission (NRC) of a safety evaluation report (SER) for the use of online monitoring as a means of extending the calibration intervals of safety-related instrumentation [2]. The MSET software described herein is configured to detect instrument degradation and perform system diagnostics with higher accuracy and faster response time than prior art techniques. This capability can substantially improve equipment availability and improve plant uptime. DIAGNOSTIC PROCEDURE OVERVIEW The software enables process engineers to define a diagnostic model for their process or equipment, optimize the design, and then automatically generate the software that performs the online diagnostic function. The model development process is accomplished using a graphical mouse-driven set of tools and a proven methodology. This combination of tools and methodology permits complex diagnostic systems to be developed in a very short amount of time. The software s validation algorithm combines MSET parameter estimators with sophisticated decision logic for a solution that provides excellent real-time performance, well-defined error rates, and is scaleable to validate any number of system signals. MSET provides a high fidelity estimate of the expected response of the system sensors by using advanced pattern recognition techniques to measure the similarity between sensor signals within a learned operational domain. The learned patterns or relationships among the signals are used to identify the operating state that most closely corresponds with the current measured set of signals. By quantifying the relationship between the current and 2
3 learned states, MSET estimates the current expected response of the system sensors. The mathematical foundations of the MSET algorithms are well described in the literature [3]. Referring to Figure 1, the overall diagnostic procedure consists of a training step and a monitoring step. The training step is used to characterize the monitored asset, such as a process or item of equipment, using historical operating data. There are two important attributes of the historical operating data used to train an MSET model of the asset. First, the data should contain all modes and ranges of operation that are to be considered normal operation of the asset. Second, the data should not contain any operating anomalies, sensor failures or equipment failures that would be considered abnormal operation of the asset. These criteria are prerequisites for the learned MSET model to fully characterize normal operation of the asset. After a comprehensive and error-free set of training data has been assembled, the MSET training algorithms are used to build an MSET model of the asset. The training procedure evaluates the training data and selects a subset of the training data observations that are determined to best characterize the asset s normal operation. First, the observations containing the minimum and maximum observed value for each included signal are selected. The minimum and maximum observed values define the valid operating range of the MSET model for the asset. The set of minimum and maximum observed values also define the smallest possible MSET model of the asset. Next, the training procedure attempts to select a number of additional points that best characterize the asset s operating states between the minimum and maximum limits. The procedure used to fill in the additional states is performed by first ordering the training data observations using a statistical method based on the Euclidean norms of the data observations. The procedure then selects observations at equal intervals to fill the MSET model with the user-specified number of operating data examples. The training step results in a stored MSET model of the asset that may be used in the monitoring step to estimate the expected values of the signals. In the monitoring step, a new observation of the asset signals is first acquired. Again referring to Figure 1, this observation is used in conjunction with the previously trained MSET model to estimate the expected values of the signals. The estimation procedure is accomplished by comparing the new observation to the previously learned examples. A weighting method is used to produce the estimate by combining the example data values. Those examples most similar to the current observation are heavily weighted while those that are dissimilar are negligibly weighted. Similarity between the current observation and the learned examples is computed using sophisticated multivariable pattern matching techniques. The weighted combination of the most similar learned examples is used to compute the estimated signal values given the current observed signal values. The MSET technique provides an extremely accurate estimate of sensor signals, with error rates that are typically 1% to 2% of the standard deviation of the input signal, which is excellent. 3
4 Training Data Calibrate Model Asset Acquire Data Online Model Parameter Estimation Training Monitoring Fault Detection Alarm or Control Action No Fault Found? Yes FIGURE 1. DIAGNOSTIC PROCEDURE OVERVIEW The difference between a signal s predicted value and its directly sensed value is termed a residual. The residuals for each monitored signal are used as the indicator for sensor and equipment faults. Instead of using simple thresholds to detect fault indications (i.e., declaring a fault when a signal s residual value exceeds a preset threshold), the software s fault detection procedure employs a proprietary Bayesian Sequential Probability (BSP) hypotheses test technique to determine whether the residual error value is uncharacteristic of the learned process model and thereby indicative of a sensor or equipment fault. The BSP algorithm improves the threshold detection process by providing more definitive information about signal validity using statistical hypothesis testing. The BSP technique allows the user to specify false alarm and missed alarm probabilities, allowing control over the likelihood of false alarms or missed detection. The BSP technique is a superior surveillance tool because it is sensitive not only to disturbances in the signal mean, but also to very subtle changes in the statistical quality (variance, skewness, bias) of the signals. For sudden, gross failures of a sensor or item of equipment, the BSP procedure will annunciate the disturbance as fast as a conventional threshold limit check. However, for 4
5 slow degradation, the BSP procedure can detect the incipience or onset of the disturbance long before it would be apparent with conventional threshold limits. In general, the BSP procedure is accomplished by first establishing the expected distribution of the residual values when the asset is operating normally. This step is accomplished in conjunction with the MSET model training procedure. Once an MSET model is trained by learning examples from the training data, the remaining (unselected) training data observations are run through the model in order to characterize the expected distribution of the residual values. Having characterized the expected distribution of the residual values when the asset is operating normally, the BSP procedure may be used to detect those conditions that deviate from the learned MSET model. In operation, a time series of residual values are evaluated to determine whether the series of values is characteristic of the expected distribution or alternatively of some other specified distribution. Four possible fault-type distributions are considered in the current software. These are: 1) the residual mean value has shifted high; 2) the residual mean value has shifted low; 3) the residual variance value has increased; and 4) the residual variance value has decreased. The sensitivity of the BSP procedure when selecting between the expected (null-type) distribution and a fault type distribution is primarily established by a user-configurable setting termed the system disturbance magnitude. The system disturbance magnitude controls the crossover point at which a disturbance in the residual values is deemed uncharacteristic of the normal operating states of the monitored asset. The definitive fault alarm decision is made using a conditional probability analysis of a series of BSP fault detection results in order to reduce the potential for single observation false alarms. The conditional probability technique improves on the conventional multi-cycle voting approach (e.g., fail on N fault indications out of the last M observations) by allowing the user to more explicitly control the statistical confidence level used in the fault alarm decision. MSET techniques have been successfully applied in a number of reliability critical applications, including monitoring of Space Shuttle s Main Engine sensors [4], military gas turbine engine sensors, industrial process equipment, high-performance computers, and nuclear power plant sensors [5,6]. POWER PLANT APPLICATIONS The design of an online diagnostic model begins with the user s definition of the signal parameters to be processed by the model. These will include all signals required for diagnostic processing, either as targets of validation or as collaborating data. A typical steam system model is illustrated in Figure 2. During online monitoring, the software displays the current signal values using data boxes that visually highlight warning and fault conditions using yellow (warning) and red (fault) backgrounds for the affected signal. The illustration in Figure 2 highlights a fault condition detected in the monitored signal 1-L-06. The display is mouse-active enabling the user to quickly drill down to retrieve detailed monitoring results, plot signals and model-generated data, or view model design information for any signal or other model element. The model represented in Figure 2 is based on actual data from an operating nuclear power plant. The model was trained at the software s default settings using data from the initial months in the plant s fuel 5
6 cycle. Several months into the fuel cycle, a drift failure in steam generator level signal 1-L-06 occurred. Referring to Figure 3, this drift event is detected by the software at the point shown. The drift error detection results for signal 1-L-06 illustrate the excellent sensitivity of the software for detecting sensor calibration drift and other common operating problems. The data plot shows the actual signal values in blue and the MSET-estimated values in red. The highly expanded scale of the dependent axis in Figure 3 makes the drift error obvious in hindsight as the problem progresses. However, the software s automated fault detection algorithms are clearly able to detect the drift in online operation more quickly than a skilled human observer. For comparison, the observed and estimated values over the training data set are shown in Figure 4. The excellent ability of the MSET algorithm to track normal trends and fluctuations in the actual signal data is readily apparent in Figure 4. The ability of the software to accurately estimate online signals from a nuclear power plant is further illustrated in Figure 5 and Figure 6. Figure 5 presents the data from a redundant steam generator level sensor during the drift event that is affecting signal 1-L-06 in Figure 3. The redundant signal 1-L-07 is accurately estimated by the MSET model despite the presence of the error in signal 1-L-06. Figure 6 presents the data for the steam generator pressure, signal 1-P-02, and illustrates the model s ability to accurately track the complicated characteristics of the monitored signals. FIGURE 2. TYPICAL STEAM SYSTEM MODEL 6
7 FIGURE 3. DRIFT ERROR DETECTION FOR SIGNAL 1-L-06 FIGURE 4. TRAINING DATA BASIS FOR SIGNAL 1-L-06 7
8 FIGURE 5. REDUNDANT SIGNAL 1-L-07 DURING DRIFT FAILURE OF 1-L-06 FIGURE 6. STEAM GENERATOR PRESSURE SIGNAL 1-P-02 8
9 POWER PLANT BENEFITS Predictive condition monitoring using online signal validation can provide management and plant operators with early indications of deteriorating sensors and equipment. With advanced warning of impending failures, management can take corrective action during periods of planned downtime, increasing the productive availability of the monitored equipment. The software s ability to detect a signal fault when it is only a fraction of the normal operating range and noise band of the signal provides a breakthrough capability for preventing unscheduled equipment downtime. Most industrial equipment provides a peak system availability of 85% to 95%. The downtime associated with industrial equipment represents a significant, and often hidden, cost. Equipment downtime for a power generating plant has a direct and immediate impact on revenues since electricity cannot be stockpiled as a buffer to protect against short-term outages. If unable to generate electricity, a generating plant will absorb lost revenues, along with the high costs of unplanned repair and maintenance. If the plant has contractual commitments to provide power, the costs of purchasing electricity on the spot market may further erode revenues. In an effort to maximize equipment availability, many generating plants have implemented intensive preventative maintenance programs. However, according to the industry research firm ARC Advisory Group, half of all preventative maintenance is unnecessary and serves only to increase maintenance costs. Predictive condition monitoring offers a practical solution to optimize a generating plant s operations and maintenance (O&M) effectiveness and minimize costs. CURRENT WORK This software is currently the focus of a significant body of work targeted at further advancing the stateof-the-art in online signal validation and diagnostic monitoring. The US Department of Energy is funding upgrades to the software to improve the level of modeling automation and develop other ease of use features to enable wide spread use throughout the power industry by requiring less algorithm expertise for successful development of effective monitoring systems. The US Air Force is funding deployment of the software into test facilities supporting gas turbine engine development with numerous new technical capabilities and performance enhancements planned. The State of California is funding the implementation an Internet-enabled client-server version of the software. EPRI and Expert Microsystems are working together to implement software upgrades and applications studies specifically supporting the requirements of the power-generating industries, and most notably the requirements of the nuclear power industry for primary side instrument calibration reduction [7]. CONCLUSIONS SureSense predictive condition monitoring software enables significantly improved asset management for power generating facilities. The software s ability to provide very early fault detection enables highly effective predictive maintenance of plant equipment and prevents forced outages and other unscheduled downtime. In the increasing competitive power generation business, this capability can provide generating plants with a significant advantage. 9
10 ACKNOWLEDGEMENTS The support of EPRI Power Production Directorate and its member utilities in the performance of this work is gratefully acknowledged. REFERENCES 1 E. Davis and R.L. Bickford, SureSense Multivariate State Estimation Studio Users Guide, Version 1.3, EPRI, Palo Alto, California, January E. Davis, D. Funk, D. Hooten, and R. Rusaw, On-Line Monitoring of Instrument Channel Performance, TR R1 NRC SER, EPRI, Palo Alto, California, September R.M. Singer, K.C. Gross, J.P. Herzog, R.W. King, and S.W. Wegerich, Model-Based Nuclear Power Plant Monitoring and Fault Detection: Theoretical Foundations, Proc. of the 9th International Conference on Intelligent Systems Applications to Power Systems, Seoul, Korea, July R.L. Bickford, et al, MSET Signal Validation System for Space Shuttle Main Engine, Final Report, NASA Contract NAS , August K.C. Gross, R.M. Singer, S.W. Wegerich, J.P. Herzog, R. VanAlstine, and F. Bockhurst, Application of a Model-Based Fault Detection System to Nuclear Plant Signals, Proc. of the 9th International Conference on Intelligent Systems Applications to Power Systems, Seoul, Korea July J.P. Herzog, S.W. Wegerich, and K.C. Gross, MSET Modeling of Crystal River-3 Venturi Flow Meters, Proc. ASME/JSME/ SFEN 6th International Conference on Nuclear Engineering, San Diego, California, May E. Davis, et al, On-Line Monitoring at Nuclear Power Plants Results From the EPRI On-Line Monitoring Implementation Project, Proc. of POWID 2002, San Diego, California, June
SureSense Software Suite Overview
SureSense Software Overview Eliminate Failures, Increase Reliability and Safety, Reduce Costs and Predict Remaining Useful Life for Critical Assets Using SureSense and Health Monitoring Software What SureSense
More informationLessons Learned From the U.S. Nuclear Power Plant On-Line Monitoring Programs
Lessons Learned From the U.S. Nuclear Power Plant On-Line Monitoring Programs J. Wesley Hines Nuclear Engineering Department, The University of Tennessee, Knoxville, Tennessee 37996-2300 jhines2@utk.edu
More informationProactive Asset Management with IIoT and Analytics
Proactive Asset Management with IIoT and Analytics by Ralph Rio in Industrial Internet of Things, Analytics & Big Data Summary The Industrial Internet of Things (IIoT) with advanced analytics, offers new
More informationPredictive Analytics uses data
Predictive Analytics in Equipment Reliability Programs Predictive Analytics in conjunction with Threat Based Maintenance (TBM ) reduces and, in some cases, can eliminate the need to perform time-based
More informationMaximizing return on plant assets
Maximizing return on plant assets Manufacturers in nearly every process industry face the need to improve their return on large asset investments. Effectively managing assets, however, requires a wealth
More informationIntroduction. Background
Predictive Operational Analytics (POA): Customized Solutions for Improving Efficiency and Productivity for Manufacturers using a Predictive Analytics Approach Introduction Preserving assets and improving
More informationIndustry Solution. Predictive Asset Analytics at Power Utilities
Industry Solution Predictive Asset Analytics at Power Utilities Overview With pressure from new regulations and consumers, operating with the highest levels of efficiency, reliability and safety is a top
More informationSPPA-D3000 Plant Monitor Technical Description
SPPA-D3000 Plant Monitor Technical Description Model-based monitoring and early fault detection for components and processes May 2008 Answers for energy. 1 Siemens AG 2008. All Rights Reserved Contents
More informationAsset management systems increase reliability and efficiency
A PublicAtion of the international Society of AutomAtion Asset management systems increase reliability and efficiency Make use of technology to overcome barriers to better maintenance practices By Augie
More informationEnterprise Asset Performance Management
Application Solution Enterprise Asset Performance Management for Power Utilities Using the comprehensive Enterprise Asset Performance Management solution offered by Schneider Electric, power utilities
More informationIntroduction. Chapter 1
Chapter 1 Introduction The area of fault detection and diagnosis is one of the most important aspects in process engineering. This area has received considerable attention from industry and academia because
More informationTechnical Review of On-Line Monitoring Techniques for Performance Assessment
NUREG/CR-6895 Technical Review of On-Line Monitoring Techniques for Performance Assessment Volume 1: State-of-the-Art University of Tennessee U.S. Nuclear Regulatory Commission Office of Nuclear Regulatory
More informationPMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions
PMCS Integrated Energy Management Solution Unlock the Full Potential of Power Networks Through Integration Power Management Control System (PMCS) is a highly customizable, fully integrated end-to-end Energy
More informationSocial Innovation through Utilization of Big Data
Social Innovation through Utilization of Big Data Hitachi Review Vol. 62 (2013), No. 7 384 Shuntaro Hitomi Keiro Muro OVERVIEW: The analysis and utilization of large amounts of actual operational data
More informationSelecting Sensors for Safety Instrumented Systems per IEC 61511 (ISA 84.00.01 2004)
Selecting Sensors for Safety Instrumented Systems per IEC 61511 (ISA 84.00.01 2004) Dale Perry Worldwide Pressure Marketing Manager Emerson Process Management Rosemount Division Chanhassen, MN 55317 USA
More informationEquipment Performance Monitoring
Equipment Performance Monitoring Web-based equipment monitoring cuts costs and increases equipment uptime This document explains the process of how AMS Performance Monitor operates to enable organizations
More informationReal-time Power Analytics Software Increasing Production Availability in Offshore Platforms
Real-time Power Analytics Software Increasing Production Availability in Offshore Platforms Overview Business Situation The reliability and availability of electrical power generation and distribution
More informationThe Advantages of Enterprise Historians vs. Relational Databases
GE Intelligent Platforms The Advantages of Enterprise Historians vs. Relational Databases Comparing Two Approaches for Data Collection and Optimized Process Operations The Advantages of Enterprise Historians
More informationREMOTE MONITORING SYSTEM MATURE FIELDS UNCONVENTIONALS MONITORING SYSTEM. Solving challenges.
REMOTE MONITORING SYSTEM InteLift REMOTE MONITORING SYSTEM Solving challenges. UNCONVENTIONALS MATURE FIELDS InteLift Remote Monitoring System InteLift REMOTE MONITORING SYSTEM YOUR RESERVES AND YOUR
More informationOn-line PD Monitoring Makes Good Business Sense
On-line PD Monitoring Makes Good Business Sense An essential tool for asset managers to ensure reliable operation, improve maintenance efficiency and to extend the life of their electrical assets. Executive
More informationISA108 Intelligent Device Management (IDM)
ISA108 Intelligent Device Management (IDM) Intelligent Digital Devices - Have Self-Diagnostics and More Eight-channel two-wire temperature transmitter Intelligent two-wire on/off valve 2 Fully integrated
More informationGROUND TEST DATA VALIDATION USING A SUBSCALE F/A-22 ENGINE INLET EMPIRICAL MODEL ±
Proceedings of GT2006 ASME Turbo Expo 2006: Power, for Land, Sea, and Air May 8-11, 2006, Barcelona, Spain GT2006-90165 GROUND TEST DATA VALIDATION USING A SUBSCALE F/A-22 ENGINE INLET EMPIRICAL MODEL
More informationPdM Overview. Predictive Maintenance Services
PdM Overview Predictive Maintenance Services Objective Assessments Maximize Uptime, Lower Costs Predictive Maintenance (PdM) solutions from Rexnord Industrial Services help manage the condition of your
More informationRecipCOM. Expertise, reciprocating compressor monitoring and protection tailored to your needs
RecipCOM Expertise, reciprocating compressor monitoring and protection tailored to your needs Do your reciprocating compressors have sufficient protection? Due to the increasing demands on availability
More informationData Cleansing for Remote Battery System Monitoring
Data Cleansing for Remote Battery System Monitoring Gregory W. Ratcliff Randall Wald Taghi M. Khoshgoftaar Director, Life Cycle Management Senior Research Associate Director, Data Mining and Emerson Network
More informationThe future of industrial asset management: New opportunities for oil and gas, power generation and aviation industries
Point of View Generating manufacturing Impact The future of industrial asset management: New opportunities for oil and gas, power generation and aviation industries Defining the right operating model for
More informationGE Energy Transformer Monitoring: How Moving forward from Monitoring to Diagnostics can Positively Impact Indian Business and Industry
GE Energy Transformer Monitoring: How Moving forward from Monitoring to Diagnostics can Positively Impact Indian Business and Industry Brian Sparling, SMIEEE GridTech 2007, Delhi February 5-6, 2007 The
More informationOperations & Maintenance 201 Using online monitoring and predictive diagnostics to reduce maintenance costs
2003 Emerson Process Management. All rights reserved. View this and other courses online at www.plantwebuniversity.com. Operations & Maintenance 201 Using online monitoring and predictive diagnostics to
More informationAssuring Global Reference Data Distribution on a Virtual Appliance
White Paper Assuring Global Reference Data Distribution on a Virtual Appliance Predictive Analytics for IT in Action January 2012 Introduction Reference data has always been critical to the trading workflow
More informationLong Term Operation R&D to Investigate the Technical Basis for Life Extension and License Renewal Decisions
Long Term Operation R&D to Investigate the Technical Basis for Life Extension and License Renewal Decisions John Gaertner Technical Executive Electric Power Research Institute Charlotte, North Carolina,
More informationSystem Aware Cyber Security
System Aware Cyber Security Application of Dynamic System Models and State Estimation Technology to the Cyber Security of Physical Systems Barry M. Horowitz, Kate Pierce University of Virginia April, 2012
More informationmonitoring water networks Identifying and Quantifying the Value of Water Network Monitoring
monitoring water networks Identifying and Quantifying the Value of Water Network Monitoring A T a K a D u W h i t e p a p e r 1. INTRODUCTION Water Network Monitoring is based on real-time analysis of
More informationCondensing PQ Data and Visualization Analytics. Thomas Cooke
1 Condensing PQ Data and Visualization Analytics Thomas Cooke Storing and Transmitting Data One Monitor / Site (2 bytes per sample) X (512 samples/cycle) X (60 cycles/sec) X (60 sec/min) X (60 min/hr)
More informationAnalytical Products and Solutions. Complete service and maintenance solutions for your analytical equipment. usa.siemens.com/analyticalproducts
Analytical Products and Solutions Complete service and maintenance solutions for your analytical equipment usa.siemens.com/analyticalproducts Support Services for Today, Tomorrow and Years to Come Providing
More informationON-LINE MONITORING OF POWER PLANTS
ON-LINE MONITORING OF POWER PLANTS Dr. Hans-Gerd Brummel Siemens Power Generation (PG), Huttenstrasse 12-16, 10553 Berlin, Germany Phone: +49 30 3464 4158, E-mail: hans-gerd.brummel@siemens.com Table of
More informationEDDYONE AUTOMATED ANALYSIS OF PWR/WWER STEAM GENERATOR TUBES EDDY CURRENT DATA
EDDYONE AUTOMATED ANALYSIS OF PWR/WWER STEAM GENERATOR TUBES EDDY CURRENT DATA ABSTRACT Dr.sc. Berislav Nadinic dipl.ing. R&D Department Manager INETEC Institute for Nuclear Technology Dolenica 28, 0000
More informationRemote diagnostic services Drive systems
Remote diagnostic services Drive systems Support whenever you need it Remote diagnostic services In an ideal world, the best way to ensure maximum production uptime is for all system experts to be on site
More informationTestScape. On-line, test data management and root cause analysis system. On-line Visibility. Ease of Use. Modular and Scalable.
TestScape On-line, test data management and root cause analysis system On-line Visibility Minimize time to information Rapid root cause analysis Consistent view across all equipment Common view of test
More informationWork Smarter, Not Harder: Leveraging IT Analytics to Simplify Operations and Improve the Customer Experience
Work Smarter, Not Harder: Leveraging IT Analytics to Simplify Operations and Improve the Customer Experience Data Drives IT Intelligence We live in a world driven by software and applications. And, the
More informationWhite Paper. Eliminating Unscheduled Downtime by Forecasting Useable Life. SiliconDrive SiSMART Technology
White Paper Eliminating Unscheduled Downtime by Forecasting Useable Life SiliconDrive SiSMART Technology "There is a strong need in the market for technology that tracks drive usage and makes accurate
More informationBeamex. Calibration White Paper. www.beamex.com info@beamex.com. How often should instruments be calibrated
Beamex Calibration White Paper info@beamex.com How often should instruments be calibrated How often should instruments be calibrated Plants can improve their efficiency and reduce costs by performing calibration
More informationGE Intelligent Platforms. Mine Performance. from GE Predictivity
GE Intelligent Platforms Mine Performance from GE Predictivity Increase throughput and availability If you re like most mining companies, you need to improve both your processes and your equipment availability
More informationSIS 401 - Smart SIS 15 minutes
2005 Emerson Process Management. All rights reserved. View this and other courses online at www.plantwebuniversity.com. SIS 401 - Smart SIS 15 minutes In this course: 1 Overview 2 Why It Matters 3 What
More informationData Analytics. How Operational Analytics can transform the grid. Sameer Tiku. Product Architect. Bentley Systems
Data Analytics Sameer Tiku Product Architect Bentley Systems How Operational Analytics can transform the grid Data heart of the digital transformation Remote sensing of objects and machines The Environment
More informationDEXTER. Ship Health Monitoring Software. Efficiency & Reliability. Smart Solutions for
DEXTER TM Ship Health Monitoring Software Smart Solutions for Energy Efficiency & Reliability DEXTER Leveraging Data for Cost Avoidance In today s economic and environmental climate, efficiency is critical.
More informationFive Essential Components for Highly Reliable Data Centers
GE Intelligent Platforms Five Essential Components for Highly Reliable Data Centers Ensuring continuous operations with an integrated, holistic technology strategy that provides high availability, increased
More informationOnline Transformer Insulation Monitoring System BushingGard Product Focus. Maximizing Transformer Uptime and Reliability
Online Transformer Insulation Monitoring System BushingGard Product Focus Maximizing Transformer Uptime and Reliability Critical Energy Transfer... Large power transformers are found around the world at
More informationOnshore Wind Services
GE Renewable Energy Onshore Wind Services www.ge.com/wind PITCH TABLE OF CONTENTS: 3 Operate and Maintain 3 Asset and Park Management 5 Turbine Maintenance 8 Enhance and Optimize 8 Wind PowerUp * Services
More informationUNITED TECHNOLOGIES CARRIER CORPORATION. Remote Monitoring MONITORING YOUR BUILDING 24/7 SO YOU DON T HAVE TO
UNITED TECHNOLOGIES CARRIER CORPORATION Remote Monitoring MONITORING YOUR BUILDING 24/7 SO YOU DON T HAVE TO One Source for Total Peace of Mind HVAC/R systems represent one of the largest investments in
More informationFrom Big Data to Smart Data Thomas Hahn
Siemens Future Forum @ HANNOVER MESSE 2014 From Big to Smart Hannover Messe 2014 The Evolution of Big Digital data ~ 1960 warehousing ~1986 ~1993 Big data analytics Mining ~2015 Stream processing Digital
More informationHarnessing the Power of Big Data for Real-Time IT: Sumo Logic Log Management and Analytics Service
Harnessing the Power of Big Data for Real-Time IT: Sumo Logic Log Management and Analytics Service A Sumo Logic White Paper Introduction Managing and analyzing today s huge volume of machine data has never
More informationINTRUSION PREVENTION AND EXPERT SYSTEMS
INTRUSION PREVENTION AND EXPERT SYSTEMS By Avi Chesla avic@v-secure.com Introduction Over the past few years, the market has developed new expectations from the security industry, especially from the intrusion
More informationMANAGING ASSETS WITH MODERN TOOLS AT WHITE BIRCH PAPER
MANAGING ASSETS WITH MODERN TOOLS AT WHITE BIRCH PAPER Eric Tremblay 1, Michel Ruel 2 1- White Birch Paper, Quebec City, Quebec, Canada 2- Top Control Inc., Quebec City, Quebec, Canada, and Green Bay,
More informationof The New England Water Works Association
Journal Our 132nd Year of The New England Water Works Association Volume 127 No. 2 June 2013 PUTNAM WATER TREATMENT PLANT AQUARION WATER COMPANY OF CONNECTICUT GREENWICH, CONNECTICUT New England Water
More informationProfit from Big Data flow. Hospital Revenue Leakage: Minimizing missing charges in hospital systems
Profit from Big Data flow Hospital Revenue Leakage: Minimizing missing charges in hospital systems Hospital Revenue Leakage White Paper 2 Tapping the hidden assets in hospitals data Missed charges on patient
More informationBeamex. Calibration White Paper. www.beamex.com info@beamex.com. How often should instruments be calibrated?
Beamex Calibration White Paper info@beamex.com How often should instruments be calibrated? How often should instruments be calibrated? An analysis will tell. Plants can improve their efficiency and reduce
More informationEmpowering intelligent utility networks with visibility and control
IBM Software Energy and Utilities Thought Leadership White Paper Empowering intelligent utility networks with visibility and control IBM Intelligent Metering Network Management software solution 2 Empowering
More informationHospital Billing Optimizer: Advanced Analytics Solution to Minimize Hospital Systems Revenue Leakage
Hospital Billing Optimizer: Advanced Analytics Solution to Minimize Hospital Systems Revenue Leakage Profit from Big Data flow 2 Tapping the hidden assets in hospitals data Revenue leakage can have a major
More informationWeb-Based Economic Optimization Tools for Reducing Operating Costs
Web-Based Economic Tools for Reducing Operating Costs Authors: Keywords: Abstract: Jeffery Williams Power & Water Solutions, Inc. David Egelston Power & Water Solutions, Inc. Browsers, Economics, Linear
More informationBasic Fundamentals Of Safety Instrumented Systems
September 2005 DVC6000 SIS Training Course 1 Basic Fundamentals Of Safety Instrumented Systems Overview Definitions of basic terms Basics of safety and layers of protection Basics of Safety Instrumented
More informationEnsuring High Performance Uplink Control and Site Switching With A Monitor and Control System
WP008 - Ensuring High Performance Uplink Control Ensuring High Performance Uplink Control and Site Switching With A Monitor and Control System Roger Franklin President and Chief Executive Officer Crystal
More informationMONITORING AND DIAGNOSIS OF A MULTI-STAGE MANUFACTURING PROCESS USING BAYESIAN NETWORKS
MONITORING AND DIAGNOSIS OF A MULTI-STAGE MANUFACTURING PROCESS USING BAYESIAN NETWORKS Eric Wolbrecht Bruce D Ambrosio Bob Paasch Oregon State University, Corvallis, OR Doug Kirby Hewlett Packard, Corvallis,
More informationpc resource monitoring and performance advisor
pc resource monitoring and performance advisor application note www.hp.com/go/desktops Overview HP Toptools is a modular web-based device management tool that provides dynamic information about HP hardware
More informationUsing HART with asset management systems
Using HART with asset management systems Since it s the most broadly deployed smart device platform, is HART the right choice for your plant? Here are some considerations for end users. John Yingst, Sr.
More informationHealth Management for In-Service Gas Turbine Engines
Health Management for In-Service Gas Turbine Engines PHM Society Meeting San Diego, CA October 1, 2009 Thomas Mooney GE-Aviation DES-1474-1 Agenda Legacy Maintenance Implementing Health Management Choosing
More informationHardware safety integrity Guideline
Hardware safety integrity Comments on this report are gratefully received by Johan Hedberg at SP Swedish National Testing and Research Institute mailto:johan.hedberg@sp.se Quoting of this report is allowed
More informationMonitoring and Control Tools for Implementing PAT
Supplement to Monitoring and Control Tools for Implementing PAT Terry Blevins and James Beall AUTHORS Innovations in process analysis and control offer significant opportunities for improving pharmaceutical
More informationMovicon in energy efficiency management: the ISO 50001 standard
Movicon in energy efficiency management: the ISO 50001 standard The importance of energy consumption within the company reflects the importance of the world energy crisis due to a growing demand and the
More informationA Risk Assessment Methodology (RAM) for Physical Security
A Risk Assessment Methodology (RAM) for Physical Security Violence, vandalism, and terrorism are prevalent in the world today. Managers and decision-makers must have a reliable way of estimating risk to
More informationREAL-TIME FLIGHT DATA VALIDATION FOR ROCKET ENGINES
REAL-TIME FLIGHT DATA VALIDATION FOR ROCKET ENGINES R.L. Bickford 1, T.W. Bickmore 2, C.M. Meyer 3, J.F. Zakrajsek 4 1 Expert Microsystems, Inc. Orangevale, California rando@expmicrosys.com 2 Intelligent
More informationScania Fleet Management. because details matter. Scania Fleet Management. Scania Services. Dedicated all the way.
Scania Services. Dedicated all the way. Scania Fleet Management Scania Singapore Pte Ltd 40, Senoko Road Singapore 758112 Tel: +65 6861 9181 www.scania.com.sg 10.1% SPEED 13.5% IDLING 27508 KM DISTANCE
More informationHP Service Health Analyzer: Decoding the DNA of IT performance problems
HP Service Health Analyzer: Decoding the DNA of IT performance problems Technical white paper Table of contents Introduction... 2 HP unique approach HP SHA driven by the HP Run-time Service Model... 2
More information5.5. San Diego (8/22/03 10/4/04)
NSF UV SPECTRORADIOMETER NETWORK 23-24 OPERATIONS REPORT 5.5. San Diego (8/22/3 1/4/4) The 23-24 season at San Diego includes the period 8/22/3 1/4/4. In contrast to other network sites, San Diego serves
More informationNew Features for Remote Monitoring & Analysis using the StreamScope (RM-40)
New Features for Remote Monitoring & Analysis using the StreamScope (RM-40) Provided by: Mega Hertz 800-883-8839 info@go2mhz.com www.go2mhz.com Copyright 2015 Triveni Digital, Inc. Topics RM-40 Overview
More informationPREDICTIVE ANALYTICS IN INTEGRITY MANAGEMENT: a smarter way to maintain physical assets
CROSSINGS: The Journal of Business Transformation PREDICTIVE ANALYTICS IN INTEGRITY MANAGEMENT: a smarter way to maintain physical assets Safe and reliable transportation of products is the backbone of
More informationCCTV - Video Analytics for Traffic Management
CCTV - Video Analytics for Traffic Management Index Purpose Description Relevance for Large Scale Events Technologies Impacts Integration potential Implementation Best Cases and Examples 1 of 12 Purpose
More informationAutomated Oil Analysis Interpretation System. www.conditionmonitoringintl.com
Automated Oil Analysis Interpretation System www.conditionmonitoringintl.com Global Solutions for Condition Monitoring Services and Support Laboratory Oil Testing Instruments Oil Samples to Check Machine
More informationFIELDBUS DIAGNOSTICS: LATEST ADVANCEMENTS OPTIMIZE PLANT ASSET MANAGEMENT
FIELDBUS DIAGNOSTICS: LATEST ADVANCEMENTS OPTIMIZE PLANT ASSET MANAGEMENT Stephen Mitschke, Manager-Fieldbus Products Fieldbus Foundation Acceptance of the Fieldbus Foundation s open, nonproprietary technology,
More informationFail-Safe IPS Integration with Bypass Technology
Summary Threats that require the installation, redeployment or upgrade of in-line IPS appliances often affect uptime on business critical links. Organizations are demanding solutions that prevent disruptive
More informationThe Business case for monitoring points... PCM architecture...
The Business case for monitoring points... Points Condition Monitoring (PCM) measures key parameters related to the performance of switch machines and turnouts in real time at every movement. Intelligent
More informationFire and Gas Solutions. Improving Safety and Business Performance
Fire and Gas Solutions Improving Safety and Business Performance Industrial Fire & Gas (F&G) systems play a critical role in protecting people, processes and the environment. They continuously monitor
More informationGE Energy. Solutions
GE Energy Wind Service Solutions Speed, competency and technology... Faster return to service GE s wind turbine fleet is one of the fastest growing and most reliable in the world. Building on a strong
More informationProficy Monitoring & Analysis. Software to harness the industrial internet
Proficy Monitoring & Analysis Suite Software to harness the industrial internet Prepare for the Industrial Internet Massive amounts of equipment and process GE, as one of the largest and most successful
More informationThe Business Case for Virtualization Management: A New Approach to Meeting IT Goals By Rich Corley Akorri
The BusinessCase forvirtualization Management: A New ApproachtoMeetingITGoals ByRichCorley Akorri July2009 The Business Case for Virtualization Management: A New Approach to Meeting IT Goals By Rich Corley
More informationGetting More from SCADA. Using SCADA software to Enhance Asset Management in an Organization. Presented by B-Scada, Inc.
Getting More from SCADA Using SCADA software to Enhance Asset Management in an Organization Presented by B-Scada, Inc. Contents What is Asset Management?... 3 Why is Asset Management Important?... 3 Who
More informationAdvanced Diagnostic/Prognostic Solutions for Information Technology (IT) UPS & Power Supply Systems
Application Note AN107 Advanced Diagnostic/Prognostic Solutions for Information Technology (IT) UPS & Power Supply Systems Overview In today s business networks, continuous operation of network devices
More informationStages of Decision Making. Chapter 15: Decision Support System and Executive Information System. Structured vs. Unstructured Decision Stages
Stages of Decision Making Chapter 15: Decision Support System and Executive Information System Decision-making phase is the first part of problem-solving process: Intelligence The military sense of gathering
More informationWELCOME. Landis+Gyr Technical Training Catalog
WELCOME Training is essential to ensure the customer s success in implementing the Smart Grid Solution. Our goal at Landis+Gyr is to provide a foundation of knowledge that will allow personnel to quickly
More informationUniformance Asset Sentinel. Advanced Solutions. A real-time sentinel for continuous process performance monitoring and equipment health surveillance
Uniformance Asset Sentinel Advanced Solutions A real-time sentinel for continuous process performance monitoring and equipment health surveillance What is Uniformance Asset Sentinel? Honeywell s Uniformance
More informationLiquids Pipeline Leak Detection and Simulation Training
Liquids Pipeline Leak Detection and Simulation Training April 2010 / White paper Make the most of your energy Summary Executive summary... p 1 Introduction... p 2 CPM methods for pipeline leak detection...
More informationDiscover Performance Through Digital Intelligence The Digital Suites for Oil and Gas
2014 Honeywell Users Group Europe, Middle East and Africa Discover Performance Through Digital Intelligence The Digital Suites for Oil and Gas Dan Obrien & Michele Loseto, Honeywell 1 Subsea Ecosystem
More informationRadiological Assessment Display and Control System
Features Fast, real-time data acquisition and control Highly reliable communication with remote terminal units Collecting, converting, integrating and analyzing data from all monitors Detecting, annunciating
More informationPredictive Maintenance for Effective Asset Management
Predictive Maintenance for Effective Asset Management Jarlath Quinn Analytics Consultant Rachel Clinton Business Development www.sv-europe.com FAQs Is this session being recorded? Yes Can I get a copy
More informationUltrasound Condition Monitoring
Ultrasound Condition Monitoring Whitepaper Alan Bandes UE Systems, Inc. Abstract: Instruments based on airborne/structure borne ultrasound technology offer many opportunities for reducing energy waste
More informationPropulsion Gas Path Health Management Task Overview. Donald L. Simon NASA Glenn Research Center
Propulsion Gas Path Health Management Task Overview Donald L. Simon NASA Glenn Research Center Propulsion Controls and s Research Workshop December 8-10, 2009 Cleveland, OH www.nasa.gov 1 National Aeronautics
More informationASSET Connect. The next level in Critical Environment Operational Efficiency
Connect The next level in Critical Environment Operational Efficiency 10-30% is the potential efficiency gain from optimized Data Centers and Critical Environments Operational Efficiency of Your Critical
More informationAMS Suite: Intelligent Device Manager
Product Data Sheet AMS Suite: Intelligent Device Manager with the DeltaV System Predict necessary maintenance activities instead of reacting to problems that are already impacting your process. Manage
More informationHigh Availability for Citrix XenApp
WHITE PAPER Citrix XenApp High Availability for Citrix XenApp Enhancing XenApp Availability with NetScaler Reference Architecture www.citrix.com Contents Contents... 2 Introduction... 3 Desktop Availability...
More informationDeploying VSaaS and Hosted Solutions Using CompleteView
SALIENT SYSTEMS WHITE PAPER Deploying VSaaS and Hosted Solutions Using CompleteView Understanding the benefits of CompleteView for hosted solutions and successful deployment architecture Salient Systems
More informationprocess Preventing Unplanned Downtime through Alarm Management: The Five Most Important Alarm Management Techniques for Preventing Unplanned Downtime
Preventing Unplanned Downtime through Alarm Management: The Five Most Important Alarm Management Techniques for Preventing Unplanned Downtime The Cost of Bad Alarm Management Alarm management within process
More information