For more information or to order, call or visit mphusky.com

Size: px
Start display at page:

Download "For more information or to order, call 1-800-277-4810 or visit mphusky.com"

Transcription

1 For more information or to order, call or visit mphusky.com

2 Table of Contents Section 1 Section 2 MPHusky Overview Page 1 Company History Associations & Certifications Page 2 Industries We Support Contact Information Page 3 Quality Systems MPHusky Cable Tray Page 4 Ladder Tray/Trough Page 5 Channel/Centray Page 67 Cable Tray Selection Charts Page 8 Techtray/Cable Way Section 3 Section 4 MPHusky CABLE BUS Page 9 Cable Bus Construction Reliability Page 10 Cost Savings/Ease of Installation Flexibility Page 11 Short Circuit Bracing Engineering/Equipment Coordination Page 12 Cable bus Support Components & Accessories Applications Page 13 Client and Partner Listing Project Profiles Pgs 1417 Project Profiles Section 5 Technical Data Page 18 Voltage and Amperage Chart Page 19 Ampacity Comparisons Page 20 Match Marked Drawings Pgs 2127 MPHusky Product Specifications For more information or to order, call or visit mphusky.com

3 Page 1 MPHusky Company History MPHusky was founded in 1955 and originally began operations as Husky Products. Over the following 50+ years of leadership and service, MPHusky has gone through several transformations and mergers, including Husky/Burndy and Metal Products, thus leading to what is today MPHusky America s leading manufacturer of Cable Tray and Cable bus Power Distribution Systems. Throughout these changes one thing has remained constant the Husky drive to be the most reliable, highest quality, cost effective and innovative manufacturer of Cable Support Systems and Cable Bus Power Distribution Systems. We have an unsurpassed commitment to customer satisfaction and service, and we are eager to earn your loyalty and trust. As we continue to build and strengthen our partnerships with our customers, we look forward to the next 50 years of service and support. Associations, Certifications and Standards: MPHusky is a charter member of NEMA, the Cable Tray Institute, and a corporate member of BICSI. Those and other certifications / associations are below: MPHusky is also audited in conformance with 10 CFR50 Appendix B Nuclear Standards (U.S. Nuclear Regulatory Commission). Our high quality systems are proven to meet and exceed the stringent requirements of 10 CFR50 Appendix B Nuclear Standards of the U.S. Nuclear Regulatory Commission, and our systems are utilized in many installations at Nuclear Power facilities throughout the United States. For more information or to order, call or visit mphusky.com

4 Page 3 MPHusky Quality Assurance Our Quality Policy At MPHusky, we are committed to producing only the highest quality products that meet or exceed our customers expectations and requirements. Our goal is to achieve 100% customer satisfaction, by delivering the best products and services, ontime and free of defect. We will achieve this individually and corporately through tested and proven processes and controls in our Quality System, with a constant focus and effort on continuous improvement. Item Standards MPHusky Quality Systems ANSI/ASQC Q (ISO 9001 Compliant) ASME NQA12004 ANSI N45.2 Cable Manufacturers: General Cable, Okonite, Kerite, Pirelli, etc. Quality Assurance Manufacturing Standards ISO 9001 Certified Includes ICEA, CSA, ANSI, IEEE Load Test Standards NEMA VE1/CSA Tray Standards Heat Rise Test Standards ANSI C37.20, C37.24, actual test results available upon request Cable Ampacity Standards IPCEA P46426; ICEA S66524; IEEE S135 CSA CEC Part 1 & C22.2; Canadian NEC Table 1 & Table 5A United States NEC Fault Bracing Standards NEC Article 370 Short Circuit Certification Grounding Westinghouse High Power Test Labs, copy of test report available upon request UL, CSA Welding AWS D1.1 (American Welding Society Structural Welding Code: Steel) AWS D1.3/D1.2: (American Welding Society Structural Welding Code: Aluminum) AWS C1.1/ANSI American Welding Society Recommended Practices for Resistance Welding ASME QW American Society of Mechanical Engineers Welding Procedure Specifications (Procedure Qualifications Record) Certified Welding Inspector QC196 Nuclear Audited in conformance with 10 CFR50 Appendix B Nuclear Standards (U.S. Nuclear Regulatory Commission) For more information or to order, call or visit mphusky.com

5 MPHusky Cable Tray Engineered to Support Reputations For more information or to order, call or visit mphusky.com

6 MPHusky Page 4 Ladder (Flange In or Flange Out) A cable tray consisting of two longitudinal side members connected by individual transverse members, designed to support power cable, control cable, instrumentation, and telecom/data. Meets NEMA 8A to 20C+ Typically used for heavier duty power applications by power plants, pulp and paper mills, petrochemical plants and industrial construction requiring strength and reliability Our flange out design utilizes exclusive technology which completely welds entire cross section of rungs to the outside of the rails for optimum structural integrity and reduced side rail rotation Best for supporting various diameter power cables, instrumentation, and control Capable of long support spans of 12 to 24 feet Available in FLANGE IN or FLANGE OUT design Significant cost savings over conduit & wire Trough (Ventrib) A cable tray consisting of a ventilated or solid bottom contained within longitudinal side members. Typically used by all industries to carry power, instrumentation, data communications, computer, telephone, control and fiber optic cables Ventilated or solid bottom designs, many with 22 gauge corrugation that is 3 times stronger and 21 times stiffer than 14 gauge flat steel bottoms Corrugated seams between jointing sections eliminate need for bottom seam splices Meets NEMA 8A to 20C + For more information or to order, call or visit mphusky.com

7 Page 5 MPHusky Channel A cable tray consisting of one piece, ventilated or solid bottom channel section, designed for use with a single power cable or multiple control or single circuit cables. Typically used by all industries as a low cost way to connect equipment to main cable tray systems Ventilated or solid bottom designs Furnished 13/ deep and or wide Compact size makes it easier to position around and connect to equipment Available in aluminum, millgalvanized steel, steel HDGAF, stainless steel and PVCcoated aluminum or steel Centray (Center Rail) A center rail cable tray for an integrated wire management system. Centray simplifies the support and routing of power and telecom/teledata cabling. A single hanger rod is used at each support point, which makes installation easier by reducing support requirements and eliminating the need to pull cable through the trapeze supports. Very few fittings and variations, as well as single bolt connections, add to the simplicity and lowest cost installation of this system. Cables can be laid on both sides Rungs come already attached transversely through either the top or bottom of the center tubular rail 50% less labor 75% less components and hardware than other trays Each rung is securely staked to the center rail in four places with 4 rung types Top Rung, Bottom Rung, Dual Width Rung, and Wall Rack Rung tips are chamfered to provide a smooth end and limit the opportunity for cable damage (optional end caps available) Meets NEMA 12B and 12C Flange in Ventray Ventrib Trough Flange Out Electray Centray Center Rail For more information or to order, call or visit mphusky.com

8 MPHusky Cable Tray Selections Page 6 ALUMINUM ELECTRAY LADDER ALUMINUM VENTRAY LADDER ALUMINUM IBEAM LADDER STEEL ELECTRAY LADDER NEMA Class NEMA Load Span Siderail Height Load Depth Tray Type Prefix Siderail Height Load Depth Tray Type Prefix Siderail Height Load Depth Tray Type Prefix Siderail Height Load Depth Tray Type Prefix 8A 50 lb/ft 8 ft. Span 3. A( )BA A( )PB A()JA A()MB 3 S( )B S( )P 8B 75 lb/ft 8 ft. Span 3. A( )BA A( )PB A()JA A()MB 3 S( )B S( )P 8C 100 lb/ft 8 ft. Span 3. A( )BA A( )PB A()JA A()MB 3 S( )B S( )P 12A 50 lb/ft 12 ft. Span 3. A( )BA A( )PB A()JA A()MB 3 S( )B S( )P 12B 75 lb/ft 12 ft. Span 3. A( )BB A( )PB A()JA A()MB 3 S( )B S( )P 12C 100 lb/ft 12 ft. Span 3. A( )CA A( )EA A()JA A()MB 3. A( )ICC A( )IEB 3. S( )BC S( )PD 16A 50 lb/ft 16 ft. Span 3. A( )CA A( )EA A()YA A()XA 3. A( )ICC A( )IEB S( )CD S( )EB 16B 75 lb/ft 16 ft. Span 3. A( )CA A( )EA A()YA A()XA 3. A( )ICC A( )IEB S( )CD S( )EB 16C 100 lb/ft 16 ft. Span A( )E A(X) 3. A( )ICC A( )IEB S( )EB 20A 50 lb/ft 20 ft. Span 3. A( )CA A( )EA A( )YA A( )XA 3. A( )ICC A( )IEB S( )CD S( )EB 20B 20C 75 lb/ft 20 ft. Span 100 lb/ft 20 ft. Span 20C+ Over 100lb 20 Ft. Span 7 7 A( )E A( )E7 A( )E1 A( )E A( )X A( )X7 A( )X1 A( )X71 For more information or to order, call or visit mphusky.com A( )ICC A( )IEB A()ICC A( )IEC S( )EB S( )EC A( )I S( )ED

9 Page 7 MPHusky Cable Tray Selections STEEL VENTRAY LADDER STEEL VENTRIB TROUGH ALUMINUM VENTRIB TROUGH FIBERGLASS VENTRAY LADDER NEMA Class NEMA Load Span Siderail Height Load Depth Tray Type Prefix Siderail Height Load Depth Tray Type Prefix Siderail Height Load Depth Tray Type Prefix Siderail Height Load Depth Tray Type Prefix 8A 50 lb/ft 8 ft. Span S( )H S( )J S( )M SH SJ SM AJA AMB B 75 lb/ft 8 ft. Span S( )H S( )J S( )M SH SJ SM AJA AMB C 100 lb/ft 8 ft. Span S( )H S( )J S( )M SH SJ SM AJA AMB A 50 lb/ft 12 ft. Span S( )H S( )J S( )M SH SJ SM AJA AMB B 75 lb/ft 12 ft. Span S( )J S( )M SJ SM AJB AMB C 100 lb/ft 12 ft. Span S( )JC S( )MD SJC SMD AYA AXA A 50 lb/ft 16 ft. Span S( )YD S( )XB SYD SXB AYA AXA B 75 lb/ft 16 ft. Span S( )YD S( )XB SYD SXB 41/8 55/8 AYA AXA 6 16C 100 lb/ft 16 ft. Span S( )XB SXB 5. AX 6 20A 50 lb/ft 20 ft. Span S( )YD S( )XB SYD SXB 5.52 AYA AXA 6 20B 20C 75 lb/ft 20 ft. Span 100 lb/ft 20 ft. Span 20C+ Over 100lb 20 Ft. Span S( )XB S( )XC SXB SXC For more information or to order, call or visit mphusky.com AX AX7 AX1 AX S( )XD SXD H6 6 6

10 MPHusky Page 8 Techtray Industry leading wire mesh cable management system developed and manufactured by MPHusky. Techtray is manufactured utilizing high strength steel wire, providing a strong yet lightweight support system that is perfect for today s high tech cabling needs. Unique 2 x 2 grid offers twice the support of 2 x systems, and is modular in any direction, allowing for lower installation cost and more support for sensitive cables Safety TWeld Edge Design eliminates sharp edges, which prevents fraying and damage to cables as well as protecting the installers from sharp wire ends Smart 90 degree corner splice connector is the only fitting that is needed to create 90 s, tee s and crosses Cable Way An economical and easy to use fully enclosed cable tray system. Smooth, solid bottom and cover (purchased separately) hides cables from view when aesthetics are important. Easy installation Quick shipment available Available in aluminum, pregalvanized and galvanneal (paint ready) For more information or to order, call or visit mphusky.com

11 MPHusky CABLE BUS Engineered to Build Powerful Reputations For more information or to order, call or visit mphusky.com

12 MPHusky Page 9 MPHusky CABLE BUS Construction MPHusky has over 45 years experience coordinating our cable bus power distribution systems with many types of applications. Our cable bus consists of a fully enclosed & ventilated metal housing and utilizes fully rated factory insulated power cables supported with nonmagnetic support blocks. MPHusky s cable support blocks are designed and manufactured to last the life of the system and are utilized to maintain individual cable spacing, as well as ensure short circuit bracing of a minimum 100KA RMS Symmetrical Amps. Our factory welded aluminum alloy enclosure provides a completely protected bus system and is provided in custom lengths, with each housing section sized to fit the specific installation. 90% of our systems utilize 6063 T6 aluminum, but we also provide stainless steel and Hot Dipped Galvanized After Fabrication Steel housings when required. And our extensive custom fabrication capabilities ensure that we can manufacture nearly any special housing, connection or accessory to manage all of your difficult coordination challenges. Each cable bus system includes all necessary power cable, equipment connections, flanges, wall entrance seals, fire stops, elbows, offsets, terminal lugs, termination kits and miscellaneous parts. Insulated neutral phase conductors and ground conductors (bare, tin plated, or insulated) are also provided as an option. A complete set of matchmarked layout drawings show the location of each section and all accessories. We utilize only the highest quality products, including: Structural 6063 T6 aluminum for standard housing along with stainless steel tie bolts for our cable support blocks, Burndy twohole long barrel compression lugs, Nelson fire stops, Raychem or 3M Termination Kits, and high quality conductors that include General, Kerite, Okonite, Pirelli, etc.. Reliability After decades of superior performance, many engineers, buyers and owners choose MPHusky Cable Bus over nonsegregated phase bus duct, conduit & wire, and cable in tray due to it s higher reliability, lowest cost, greater flexibility and maintenancefree construction. Our cable bus design provides superior reliability by utilizing high quality, continuous run power cables (no splices) that are completely protected in a ventilated metal housing. And since our system design is not affected by moisture and is ventilated for outdoor and indoor applications, it does not require For more information or to order, call or visit mphusky.com

13 Page 10 MPHusky heater strips or filter breathers that competitive technologies require to try to keep moisture out of their system. Our systems are tested and fieldproven in some of the most extreme environments and weather conditions including Paper Mills, Fossil Fuel Burning Facilities, Chemical Plants, Mining Facilities, Heavy Salt Environments, Cold Areas (North Canada, Alaska), Hot Areas (Saudi Arabia) and Tropical Areas (Puerto Rico and Nigeria). And our extensive experience and knowledge with the widest range of applications and environments, along with our superior engineering and design, provides you with a real advantage in reliability and proof of design. The bottom line is when you choose MPHusky CABLE BUS, you ensure you will have the most reliable power distribution system, whether compared to competing technologies or other cable bus manufacturers. Cost Savings/Ease of Installation Typical cost savings realized with MPHusky Cable Bus over competitive technologies such as NonSegregated Phase Bus Duct, Conduit & Wire, and Cable in Tray range from 15% to 50%+. And our optimal design, which includes our exclusive corrugated and ventilated top and bottom housing, as well as our continuous parallel conductors (no interleaving) throughout the entire run of housing, can save you 10% 25% over other cable bus systems installed costs. Our engineered design achieves a free air rating of the power cables; the competition often has to derate cables, leading to higher conductor costs of up to 40%. Combine this lower upfront system cost with the easiest installation, and MPHusky s Cable Bus System is the most costeffective power distribution system available. Easy installation is achieved through our matchmarked layout drawings and single phasing arrangement throughout the entire cable bus run. Most of our competitors use multiple phasing arrangements, which requires interleaving cables inside the bus housing, creating expensive and confusing installations. MPHusky Cable Bus does not interleave or transpose cables in the bus housing. Another advantage our cable bus housing only weighs 5 7 lbs./ft., therefore 12 sections can easily be handled by two men without the aid of heavy equipment such as cranes, booms or lifts; and our cable bus housing is designed and manufactured with the bottom cable support block factory installed, saving you more on installation costs. Flexibility MPHusky s Cable Bus systems are flexible and adaptable to the many unexpected circumstances that occur during construction. Every size and rating of cable bus provided is supplied, free of charge, with up to 5% extra cable as well as one spare length of housing including cover, cable support blocks and hardware. This enables the installer to adjust our system in the field to discrepancies or differences between engineering drawings and actual field construction, with little or no delay of the project. And our compact design and radius bends allows our system to maneuver around and fit in the lowest clearance applications. For more information or to order, call or visit mphusky.com

14 MPHusky Page 11 Cable Bus Short Circuit Bracing Cable bus support blocks are spaced every 18 in vertical applications and 3 in horizontal applications. This ensures proper cable arrangement and spacing, while providing short circuit bracing of 100kA RMS Symmetrical (actual short circuit test certification available). Our support blocks are made of select hard rock maple treated for preservation and are constructed to last for the life of the system. For tropical environments, we also provide HDPE (High Density Polyethylene) support blocks. Bottom support blocks come factory preassembled in the bottom section of the housing assembly and corresponding layers of support blocks are then fastened with stainless steel bolts. Engineered System MPHusky Cable Bus is a completely engineered system. You supply the power routing and termination details and we do the rest. MPHusky s experienced and knowledgeable engineers layout and design a custom system that is specific to your requirements. Our exclusive Inductive Reactance Program is used to design optimum phasing arrangements that minimize losses and imbalance in the system. The Inductive Reactance Calculations cover impedance values, voltage drop and power loss, which we provide to you as part of our system. We also offer inhouse lab testing for current and special applications, as well as custom fabrication capabilities that can accommodate nearly any coordination challenge. As part of our engineering services, we provide short circuit calculations and actual shortcircuit test results, and we also offer heat rise calculations with actual heat rise test results. And we recognize the value of our engineering service goes beyond our design and drawings. Thus, we provide field engineering services prior to and during engineering and construction, as well as during and after project startup. We rely on building longterm, trustworthy relationships, and thus nothing less than 100% customer satisfaction at all stages of the project is acceptable. Equipment Coordination MPHusky has extensive custom fabrication capabilities, ensuring that no matter what coordination challenges exist, if the physical space exists to maintain clearances, we can fit our cable bus system to whatever needs to be connected. We have built anything from simple box extensions for transformers to 4 feet square by 10 feet tall custom generator termination boxes. MPHusky has terminated to transformers manufactured by most manufacturers including, Carte, Northern, ABB, GE and others. We have made custom boxes to make cable terminations where no provisions for such existed, such as generator stepup transformers with 15kV cover mounted bushings intended for overhead substation line termination. We have also coordinated with most major switchgear and MCC manufacturers, from 480V though 35kV, including ArcResistant switchgear. Switchgear Manufacturers include ABB, Allen Bradley, Cutler Hammer, Siemens, GE and others. For more information or to order, call or visit mphusky.com

15 Page 12 MPHusky Cable Bus Support Our systems are supported according to NEMA Std. VE with standard supports installed 12ft. on center (can also be installed 20ft. on center load test report available when requested). We can engineer and manufacture various structural and trapeze supports, providing you everything you need to complete your cable bus system. Structural supports include Ttype, Hframe, Cantilever, and Bridge, as well as several types of wall supports. Special Housing Material: Standard Bare 6063 T6 Aluminum Hot Dipped Galvanized after Fabrication Steel Stainless Steel Anodized Aluminum Epoxy Paint System Components and Accessories: Box Connectors Tap Boxes ESF Watertight Seals CEF Watertight Seals Fire stop/watertight Seals Termination Boxes Termination Kits Long Barrel Compression Lugs Fire Stop Box Connector Tap Box CEF Watertight Seal ESF Watertight Seal Cable bus Applications: 600V to 69kV, 1000A to 8000A Service Entrance Applications Primary and Secondary Feeders Generators to Transformers Generators to Switchgear Transformers to Switchgear Switchgear to Switchgear and MCC s MCC s to Large Motors Special Applications: Large Ships OffShore Oil Drilling Ships UPS Systems For more information or to order, call or visit mphusky.com

16 MPHusky Page 13 Below is a partial list of our clients and partners: AEP Alabama Power Company AMOCO Arkansas Light & Power Atlantic Ritchfield Avantech AVCO Corporation Bechtel BE&K Bell Aero Space Bendix Corporation Black & Veatch BMW Manufacturing BP (British Petroleum) Bowater Burns & McDonnell Burns & Roe California Plaza Carborundum Co. Central Hudson G&E Central Illinois Public Services CH2M Hill Chemico Chevron Chrysler Corporation Cleveland Electric Illuminating CNRL Conemaugh Station Conoco Phillips Consolidated Aluminum Corning CP&L (Carolina Power & Light) Dashiell Corporation Dayton Power & Light Dow Chemical Dow Corning Dravo Corporation DSME Duke Power DuPont Duquesne Light Co. ExxonMobil Fisher Body Florida Power & Light Fluor Corporation FMC Corporation Georgia Electric Energy GE Engineering GE Power Georgia Pacific Georgia Power Goodyear Tire & Rubber Grede Foundries Halliburton Hawaiian Electric Hill Electric City of Houma, LA Houston Power & Light Hydro Quebec International Paper Irving Oil J.I. Case Jacobs Engineering John Deere Company Kaiser Aluminum KBR LA County Sanitation LA Dept of Power & Light Lockwood Greene Lower Colorado River Authority MA Electric Company Marlowe Manufacturing Michelin Milliken Mitsubishi Heavy Industries Monogahela Power Montana Power Medical Univ. of SC Mustang Engineering NASA City of Natchitoches, LA Northern States Power PP&L P.P.G. PS&G PhelpsDodge Corporation Progress Energy Rexham Corporation ReynoldsJamaica City of Russell, KS Santee Cooper Sargent & Lundy Saudi Aramco SCE & G Shaw, Stone & Webster Siemens City of St. Cloud, FL SNC Lavalin Southern Company Services Southwestern Pub. Svc. Co. Suncor Millenium Syncrude Tampa Electric Techint Technip Texas Utility Services Toyota Toyo Tire Transalta Energy TVA Union Carbide Union Electric Utah Power & Light Utility Engineering Valero Virgin Island Power & Light Washington Group WE Energies Weyerhauser Wisconsin Power & Light World Waste International Worley Parsons For more information or to order,

17 Page 14 MPHusky Industry: Location: Project Type: MPH Project Value: Work Scope: Power Generation United States FGD Scrubber, Coal Fire Power Plant U.S. $1,185,000 8kV 2500A Cable bus System for Scrubber application. Total of four bus runs measuring over 1,000 ft. long each. Connections were from transformer to switchgear. Industry: Location: Project Type: MPH Project Value: Work Scope: Utility United States Power Generation U.S. $709, V 4000A and 5000A, 5kV 3000A Cable bus runs were provided to this client. The connections were transformer to switchgear and generator to switchgear. Industry: Location: Project Type: MPH Project Value: Work Scope: Utility China New Power Generation U.S. $1,137,432 6x350MW Generating Units. Cable bus systems furnished for 15kV 2500A and 3000A systems. Generator leads, transformer to switchgear and switchgear tie bus connections. For more information or to order, call or visit mphusky.com

18 MPHusky Page 15 Industry: Location: Project Type: MPH Project Value: Work Scope: Paper Mill United States Modernization Project U.S. $397, V 4000A and 5kV 3000A Cable bus Systems. Connections were transformer to switchgear leads. Stainless steel Cable bus housing was used for the bleach plant and aluminum housing was used for the paper machine area. Industry: Location: Project Type: MPH Project Value: Work Scope: Petrochemical Canada Cogeneration Project U.S. $692,500 5kV 3500A and 600V 3200A Cable bus Systems. Included generator leads and transformer to switchgear applications. Industry: Location: Project Type: MPH Project Value: Work Scope: Cement Plant Nigeria Cogeneration U.S. $480,000 15kV 2700A, 35kV 1200A and 600V 6000A Cable bus Systems for Turbine Generator leads. Transformer to switchgear connections. For more information or to order, call or visit mphusky.com

19 Page 16 MPHusky Industry: Location: Project Type: MPH Project Value: Work Scope: Agricultural Processing United States Main Feeder U.S. $212,000 15kV 5000A Cable bus System. Connections were from main generator to transformer. Each of the cable bus runs were several hundred feet long. Industry: Location: Project Type: MPH Project Value: Work Scope: Petrochemical Canada Cogen Facility U.S. $438,000 Design of a 35kV 2500A Cable bus Run. The bus run tied together their main transformer to a new switchgear house. This bus run traveled across the entire plant with an approximate length of over 2,000 ft. Special Requirements: MPHusky used our 20ft. support span housing design to save the client money. We also designed and tested our bus for a trench application that allowed the client to run underground in their substation, leaving access for equipment upgrades. Industry: Location: Project Type: MPH Project Value: Work Scope: Petrochemical United States Cogeneration Project U.S. $371,000 15kV 3000A and 600V 3200A Cable bus System for Primary Feeder application. Connections from transformer to reactor to switchgear. For more information or to order, call or visit mphusky.com

20 MPHusky Page 17 Industry: Location: Project Type: MPH Project Value: Work Scope: Food Industry United States Main Feeder U.S. $50, V 4000A Cable Bus System. Utilized a special transition box design to transition from our Cable bus to an underground transformer vault, which fed from a pad mounted transformer. Power was then provided to indoor switchgear. Industry: Location: Project Type: MPH Project Value: Work Scope: Petrochemical Canada Main Power Distribution U.S. $634,000 Design of three 15kV Cable bus Runs at 3000A and one bus run at 4000A. These bus runs tied into the main transformers at 3 different Switchgear houses located at various points in the plant. Cable bus lengths were over 1,000 ft. each. Special Requirements: MPHusky also designed a special housing to accommodate the 20ft. spans used on the pipe racks. This design allowed the Cable bus housing to be installed on the pipe racks at a manufacturing facility in Edmonton and then shipped to the project site. Industry: Location: Project Type: MPH Project Value: Work Scope: Utility United States Main Power Distribution U.S. $2,287,000 Power Distribution for Flue Gas Desulphurization Project using over 25 Cable bus runs. The main transformers had double windings rated at 7kV & 15kV. MPHusky supplied two 3000A Cable bus runs from each transformer to the main switchgear house. From there, we supplied 2000A & 1200A Cable bus runs out to five unit switchgear houses. These Cable bus runs parallel each other along a pipe bridge and then drop off to each of the unit switchgear houses. Some of these runs exceed 1,000 feet in length. For more information or to order, call or visit mphusky.com

21 Page 18 MPHusky MPHUSKY CABLE BUS Available Voltage & Current Ratings 69k V 45kV 25kV 15kV 5kV 600V 800 A 1200 A 1600 A 2000 A 2500 A 3000 A 3500 A 4000 A 5000 A 6000 A 7000 A 8000 A 9000 A A KEY Definite Cost Savings on these Available Ratings Possibly Available or Economical, Consult Factory Outside Practical or Economical Range MPHusky Cable bus Features: Engineered System with the industry exclusive Inductive Reactance Calculations available upon request for the design engineer. High fault capacity. Cable bus is certified up to 100kA RMS Symmetrical and has been tested up to 120kA RMS Symmetrical. Lowest Installation Costs of any cable bus duct on the market, with the industry exclusive straight cable runs. No cable transpositions within the housing, regardless of run length. Installation savings of 10% top 25% depending on run length and cable size. Widest available range of Voltage Class and Ampere Ratings in the industry. For more information or to order, call or visit mphusky.com

22 MPHusky Page 19 AMPACITY COMPARISONS This table illustrates the greater current carrying capacity of CABLE BUS as compared to alternate methods. The increased capacity is due to free air ventilation and maintained cable spacing. (Based on NEC & ICEA Tables at 90 C in 40 Ambient) Three Single Interlocked Conductor Conductor Armored Cable Cables in Size CABLE BUS (In Tray) Conduit (In Air) 600V System 500 MCM 637 Amps 405 Amps 477 Amps 750 MCM 805 Amps 500 Amps 598 Amps 1000 MCM 960 Amps 585 Amps 689 Amps 5KV System 500 MCM 688 Amps 425 Amps 473 Amps 750 MCM 889 Amps 525 Amps 579 Amps 1000 MCM 1061 Amps 590 Amps 659 Amps 15KV System 500 MCM 678 Amps 470 Amps 481 Amps 750 MCM 872 Amps 570 Amps 588 Amps 1000 MCM 1040 Amps 650 Amps 677 Amps 600V Systems 500 MCM 594 Amps 355 Amps 355 Amps (Canadian) 750 MCM 760 Amps 450 Amps 450 Amps 1000 MCM 900 Amps 526 Amps 526 Amps For higher amperage & voltage requirements up to 8,000A and 69KV, please contact the factory. Please note: Additional derivatives may apply based on the amount of interlocked armored cables used and the spacing between conductors. For more information or to order, call or visit mphusky.com

23 Page 20 MatchMarked Layout Drawings For more information or to order, call or visit mphusky.com

24 Specifications For more information or to order, call or visit mphusky.com

25 Page 21 Typical Specifications for MPHusky Ladder Tray 1.0 Specification for Aluminum and Steel Ladder 2.0 General 2.1 Cable tray systems shall be of the design of one manufacturer and shall be designed so that there are no burrs, projections, or sharp edges to damage cable insulation. 2.2 Fittings shall have the same load carrying capacity as straight sections. Fittings shall be of the continuous arc type with a 12, 24, 36, or 48 inch radius, unless otherwise shown on the drawings. 2.3 Ladder type tray straight sections shall be 12 0 or 24 0 long and shall be of the width indicated on the drawings to provide the planned cable capacity. 3.0 Material and Construction 3.1 Aluminum Ladder type cable tray longitudinal members shall be 41/2 or deep extruded aluminum channels of 6063T6 aluminum alloy. Steel Ladder type cable tray shall be mill galvanized (ASTM A525), hot dip galvanized after fabrication steel (ASTM A123), 304 stainless steel, or 316 stainless steel. 3.2 Aluminum Ladder transverse members (rungs) shall be of extruded aluminum alloy 6063T6 and shall be designed to prevent collection pockets for moisture of contaminant materials. Steel Ladder type cable tray longitudinal members shall be 33/8, 41/2 or deep and the transverse members (rungs) shall be designed to prevent collection pockets for moisture or containment materials. 3.3 Flange Out Electray Transverse members (rungs) shall be inserted into a slot punched in the longitudenal members conforming to the contour of the transverse member and heliarc welded on the outside of the longitudinal member. Transverse members shall be located on, 9 and 12 (Steel) and 9, 12 and 18 (Aluminum) spacing. Flanges on straights and fittings shall point outward. Flange In Ventray Transverse members (rungs) shall be joined to the longitudinal members by means of a minimum of two resistance welds or two high strength clinches at each end of the transverse member. Transverse members shall be located on, 9, and 12 spacing. Flanges on straights and fittings shall point inward. 4.0 Splice Joints 4.1 Resistance across any splice connection shall not exceed 330 microhms. 4.2 Splice connector design shall be universal for use on straight sections and fittings. 4.3 Splice connectors shall be of the high pressure bolted type with a minimum of six bolts per connector. 5.0 Loading 5.1 Ladder type cable tray shall have a load safety factor of 1.5 based on the destruction load capacity as defined within NEMA Standard VE The ladder type cable tray shall meet or exceed the following NEMA load classification: 8A (50lbs. per ft./8ft. Span) 8B (75lbs. per ft./8ft. Span) 8C (100lbs. per ft./8ft. Span) 12A (50lbs. per ft./12ft. Span) 12B (75lbs. per ft./12ft. Span) 12C (100lbs. per ft./12ft. Span) 16A (50lbs. per ft./16ft. Span) 16B (75lbs. per ft./16ft. Span) 16C (100lbs. per ft./16ft. Span) 20A (50lbs. per ft./20ft. Span) 20B (75lbs. per ft./20ft. Span) 20C (100lbs. per ft./20ft. Span) 6.0 UL 6.1 The cable tray system shall be classified for use as an equipment ground and requires that the minimum cross sectional area be shown on the tray labels. The industry standard is to mark each straight section and fitting with its own cross sectional area. It is the responsibility of the installer and or user to assure that the capacity of the overall system is adequate to meet the anticipated ground fault of the system. 7.0 Manufacture and Data 7.1 The following data shall be provided with the quotation: (a) Simple beam load and deflection tables (b) Drawings illustrating tray quoted and splice connection 7.2 Tray shall be manufactured in accordance with and by a member of NEMA VE1. For more information or to order, call or visit mphusky.com

26 Typical Specifications for MPHusky Trough Tray Page Specification for Aluminum and Steel Trough 2.0 General 2.1 Cable tray systems shall be of the design of one manufacturer and shall be designed so that there are no burrs, projections, or sharp edges to damage cable insulation. 2.2 Fittings shall have the same load carrying capacity as straight sections. Fittings shall be of the continuous arc type with a 12, 24, 36, or 48 inch radius, unless otherwise shown on the drawings. 2.3 Trough type tray straight sections shall be 12 0 or 24 0 long and shall be of the width indicated on the drawings to provide the planned cable capacity. 3.0 Material and Construction 3.1 Aluminum Trough type cable tray longitudinal members shall be 41/2 or deep extruded aluminum channels of 6063T6 aluminum alloy. Steel Tray shall be steel mill galvanized (ASTM A525) or hot dip galvanized after fabrication steel (ASTM A123). Note: For trays over 2 wide or trough style trays manufactured from 304 or 316 stainless steel, use ladder type construction (Ventray) with close rung spacing. Steel Trough type cable tray longitudinal members shall be 33/8, 41/2 or deep. 3.2 Aluminum Trough bottom shall be of corrugated sheet type construction. Corrugation shall be approxi mately 3/8 deep on 11/2 pitch to provide a minimum cable support surface of per linear foot of tray height. The corrugated bottom shall be attached to the bottom flange of the channel shaped longitudinal member by means of resistance welding or high strength clinches at a minimum of 3 intervals. Note: For trays over 2 wide, use ladder type construction (Ventray) with close rung spacing. 3.3 Ventrib w/solid Bottom The solid bottom trough style tray shall be constructed of continuous solid corrugation. Flanges on straights and fittings shall point inward. 3.4 Ventrib w/ventilated Bottom The ventilated bottom trough style tray shall be constructed of continuous ventilated corrugation. The corrugation shall have a minimum of 40% open area to provide adequate ventilation for cables. Flanges on straights and fittings shall point inward. 4.0 Splice Joints 4.1 Resistance across any splice connection shall not exceed 330 microhms. 4.2 Splice connector design shall be universal for use on straight sections and fittings. 4.3 Splice connectors shall be of the high pressure bolted type with a minimum of six bolts per connector. 5.0 Loading 5.1 Trough type cable tray shall have a load safety factor of 1.5 based on the destruction load capacity as defined within NEMA Standard VE The trough type cable tray shall meet or exceed the following NEMA load classification: 8A (50lbs. per ft./8ft. Span) 8B (75lbs. per ft./8ft. Span) 8C (100lbs. per ft./8ft. Span) 12A (50lbs. per ft./12ft. Span) 12B (75lbs. per ft./12ft. Span) 12C (100lbs. per ft./12ft. Span) 16A (50lbs. per ft./16ft. Span) 16B (75lbs. per ft./16ft. Span) 16C (100lbs. per ft./16ft. Span) 20A (50lbs. per ft./20ft. Span) 20B (75lbs. per ft./20ft. Span) 20C (100lbs. per ft./20ft. Span) 6.0 UL 6.1 The cable tray system shall be classified for use as an equipment ground and requires that the minimum cross sectional area be shown on the tray labels. The industry standard is to mark each straight section and fitting with its own cross sectional area. It is the responsibility of the installer and or user to assure that the capacity of the overall system is adequate to meet the anticipated ground fault of the system. 7.0 Manufacture and Data 7.1 The following data shall be provided with the quotation: (a) Simple beam load and deflection tables (b) Drawings illustrating tray quoted and splice connection 7.2 Tray shall be manufactured in accordance with and by a member of NEMA VE1. For more information or to order, call or visit mphusky.com

27 Page 23 Typical Specifications for Techtray (Wire Mesh) 1.0 Specification for Techtray / Wire Mesh Cable Support System 2.0 Manufacturer: MPHusky, 204 Old Piedmont Hwy, Greenville, SC 29605, or Product Description: Techtray is a wire mesh cable tray system that utilizes high mechanical strength steel wire that is welded into a grid system. This grid system is then formed into channels which support and carry cables. The wire mesh will consist of a 2 x 2 grid system, and will utilize wires that have a minimum diameter of.1 (4mm). 4.0 Material: Standard tray finish shall be mill galvanized. Other finish options include Electroplated Zinc, Hot Dipped Galvanized after fabrication, Yellow Zinc Dichromate, Painted or Stainless Steel. 5.0 Safety Edge: Wire mesh system shall have continuous top edge wire that is TWelded on top of support wires to avoid sharp edges that may damage cable or installer. 6.0 Fittings: Shall be fabricated in the field by cutting wires with a cutting device. Cuts shall be made in a manner reducing sharp edges and projections so they do not harm cables or installation personnel. Manufacturer shall offer corner connectors that provide a radius on the inside corner of bends for horizontal 90 degree bends, tees, and crosses. 7.0 Straight sections shall be provided in 10 (3m) lengths. 8.0 Wire mesh shall be welded at all intersections. 9.0 Mesh system will permit continuous ventilation of cables and maximum disposition of heat. Tray shall be manufactured in accordance with NEMA VE1 and shall be installed in accordance with NEMA VE2. For more information or to order, call or visit mphusky.com

28 Typical Specifications for Fiberglass Tray Page Cable Tray Design 1.1 Cable Tray System shall be made of straight sections, fitting and accessories as defined in the latest NEMA FG Cable Tray Design 2.1 Straight section structural elements: side rails, rungs and splice plates shall be pultruded from glass fiber reinforced polyester or vinylester resin. 2.2 Pultruded shapes shall be constructed with a surface veil to insure a resinrich surface and ultraviolet resin. 2.3 Pultruded shapes shall meet ASTM E84, Class 1 flame rating and selfextinguishing requirements of ASTM D Construction 3.1 Straight section lengths will be 120 inches (10ft.) or 240 inches (20ft.) standard. 3.2 Side rails will be inward C configuration and be predrilled to accept splice plates. 3.3 Loading depths for cable tray systems shall be, 3 or 2 as per NEMA FG1 tolerances. Overall heights shall be, and 3 respectively. 3.4 Loading classifications and test specimens shall be per NEMA FG Fitting 4.1 Molded fittings shall be formed with a minimum 3 tangent following the radius or loading depth systems shall have 90 and 45 molded fittings in 12 or 2 radius. 4.3 All fittings not included in should be of mitered construction. 4.4 Width usable inside tray width shall be Outside widths shall not exceed inside by more than Straight and expansion splice plates will be of stainless steel or fiberglass design with an eight bolt pattern in fill systems and four bolt pattern in 3 and 2 fill systems. 4.6 Dimension tolerances will be per NEMA FG Cable tray must have integral connection between side rails and rungs consisting of nonmetallic mechanical fasteners and adhesive bonding. 5.0 Manufacture 5.1 All manufacturing practices will be in accordance with NEMA FG1. For more information or to order, call or visit mphusky.com

29 Page 25 Typical Specifications for Centray (Center Rail) 1.0 Cable Tray Material 1.1 The tray shall be manufactured from 6063T6 high strength aluminum. The spine shall be a minimum of 3 high and 11/2 wide. The top and bottom portions of the spine shall have a minimum thickness and vertical web portions of the spine shall have a minimum thickness of 0.1. The rung shall be a minimum of 0.50 wide by 0.60 thick. The ends of the rungs shall be rounded to prevent damage. 2.0 Cable Tray Design 2.1 Straight section structural elements: side rails, rungs and splice plates shall be pultruded from glass fiber reinforced polyester or vinylester resin. 2.2 Pultruded shapes shall be constructed with a surface veil to insure a resinrich surface and ultraviolet resin. 2.3 Pultruded shapes shall meet ASTM E84, Class 1 flame rating and selfextinguishing requirements of ASTM D Construction 3.1 Straight section lengths will be 120 inches (10ft.) or 240 inches (20ft.) standard. 3.2 Side rails will be inward C configuration and be predrilled to accept splice plates. 3.3 Loading depths for cable tray systems shall be, 3 or 2 as per NEMA FG1 tolerances. Overall heights shall be, and 3 respectively. 3.4 Loading classifications and test specimens shall be per NEMA FG Fitting 4.1 Molded fittings shall be formed with a minimum 3 tangent following the radius or loading depth systems shall have 90 and 45 molded fittings in 12 or 2 radius. 4.3 All fittings not included in should be of mitered construction. 4.4 Width usable inside tray width shall be Outside widths shall not exceed inside by more than Straight and expansion splice plates will be of stainless steel or fiberglass design with an eight bolt pattern in fill systems and four bolt pattern in 3 and 2 fill systems. 4.6 Dimension tolerances will be per NEMA FG Cable tray must have integral connection between side rails and rungs consisting of nonmetallic mechanical fasteners and adhesive bonding. 5.0 Manufacture 5.1 All manufacturing practices will be in accordance with NEMA FG1. For more information or to order, call or visit mphusky.com

30 Typical Specifications for Cable Way Page Specification for Cable Way Tray 2.0 General 2.1 Cable tray systems shall be of the design of one manufacturer and shall be designed so that there are no burrs, projections, or sharp edges to damage cable insulation. 2.2 Fittings shall have the same load carrying capacity as straight sections. Fittings shall be of the continuous arc type with a 12, 24 or 36 inch radius unless otherwise shown on the drawings. 2.3 Trough type tray straight sections shall be 10 or 12 long and shall be of the width indicated on the drawings to provide the planned cable capacity. 3.0 Material and Construction 3.1 Trough type cable tray galvannealed sides shall be 33/8,, or deep. 3.2 Tray shall be steel mill galvanized (ASTM A525) or hot dip galvanized after fabrication (ASTM A123) or 304 or 316 stainless steel. 3.3 Trough bottom shall be of solid flat sheet type construction. Flanges on straights and fittings shall point inward. 4.0 Splice Joints 4.1 Resistance across any splice connection shall not exceed 330 microhms. 4.2 Splice connector design shall be universal for use on straight sections and fittings. 4.3 Splice connectors shall be of the high pressure bolted type with a minimum of four bolts per connector. 5.0 Manufacture 5.1 All manufacturing practices will be in accordance with NEMA VE1. For more information or to order, call or visit mphusky.com

31 Page 27 Typical Specifications for CABLE BUS 1.0 General 1.1 A complete metal enclosed bus system shall be provided; including all necessary fittings, tap boxes, enclosure connectors, entrance fittings, insulated conductors, electrical connectors, terminating kits, and other accessories as required. 1.2 The bus system shall be suitable for indoor or outdoor use with conductor spacing and ventilation maintained throughout the system. 1.3 All elements of the bus enclosure shall be so designed as to eliminate any sharp edges or projections that may injure personnel or conductor insulations. 1.4 The bus system shall be CABLE BUS, as manufactured by MPHusky. 2.0 Construction 2.1 All load carrying members of the bus system shall be fabricated from extrusions of aluminum alloy 6063T6. The maximum allowable stress used in designed shall be 10,000 PSI. 2.2 Bus enclosure fittings shall have a radius of 24 inches, unless the minimum bending radius of the conductor requires a larger fitting radius. 2.3 The top and bottom enclosure sections shall be corrugated to provide mechanical strength and slotted for ventilation. The top cover shall be fastened to the enclosure with self tapping screws spaced approximately 2 feet on centers and shall be removed for inspection. The bottom section shall be factory installed by welding. 2.4 Splice joints between sections of the bus enclosure shall be the high pressure splined bolted type of a design which avoids any structural weakness at the connection and does not exceed the electrical resistance specified under Section 3.4 of this specification. 2.5 Conductor support blocks shall be designed in segments to maintain a minimum of one conductor diameter in both the horizontal and vertical planes, as required for free air conductor rating. Horizontal runs will have blocks spaced every 3 and vertical runs every Electrical 3.1 All current carrying conductors shall have insulation rated for 90 C operating temperature in accordance with ICEA publication #P46426 and interim STD #1&#2 to ICEA publication #S66524 for the ampacity and voltage specified. 3.2 The conductors shall be phased and supported to maintain low impedance and assure the mechanical strength necessary to prevent cable movement or damage under short circuit currents up to 100,000 RMS symmetrical amps. 3.3 Conductors shall be of continuous length and be pulled in after the bus enclosure is in place. Electrical connectors shall be used only at the termination of conductor runs or, if necessary, at tap points. All electrical connectors shall be provided by MPHusky. 3.4 The bus enclosure shall have a continuous current rating of not less than 1,000 amperes (50 C Rise) and the resistance across the enclosure section splice shall not exceed 50 microhms. 3.5 The bus enclosure shall be grounded at sufficient intervals for the purpose of preventing a potential above ground on the bus enclosure in the event of a fault. 3.6 The conductors shall be arranged in a phasing pattern which exhibits minimal interphase and intraphase imbalance. 3.7 Conductor temperature rise calculations and current balance calculations can be provided in support of Section 3.6 of this specification. 3.8 All transposing of cables must occur at termination points. Transposing of cables will not be one in the bus housing. For more information or to order, call or visit mphusky.com

32 204 Old Piedmont Hwy Greenville, SC m p h u s k y. c o m For more information or to order, call 1800

CT-02 CABLE TRAY SYSTEMS

CT-02 CABLE TRAY SYSTEMS CT-02 CABLE TRAY SYSTEMS SYSTEMS THAT MAKE SENSE Introduction B-Line Systems was formed in 96 and has over 30 years experience manufacturing cable tray systems in which it has grown to become the industry

More information

POWER MANUFACTURING OIL & GAS CHEMICAL CABLE BUS. The Most Reliable, Cost-effective, Flexible & Maintenance-free Power Distribution System

POWER MANUFACTURING OIL & GAS CHEMICAL CABLE BUS. The Most Reliable, Cost-effective, Flexible & Maintenance-free Power Distribution System POWER MANUFACTURING OIL & GAS CHEMICAL CABLE BUS The Most Reliable, Cost-effective, Flexible & Maintenance-free Power Distribution System Decade after decade, for 60 years and running, MP Husky continues

More information

SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such

More information

T&B Cable Tray. Metallic Aluminum. Straight Lengths. Tray Bottom Types Ladder, Ventilated and Solid Trough

T&B Cable Tray. Metallic Aluminum. Straight Lengths. Tray Bottom Types Ladder, Ventilated and Solid Trough Tray Bottom Types Ladder Extra wide aluminum rungs are welded to extruded aluminum I-beam siderails. Every second rung is reversed to allow for easy top or bottom mounting of cable ties and clamps. All

More information

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE: 10.17.12

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE: 10.17.12 SECTION 27 05 26 - GROUNDING AND BONDING FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes grounding and bonding products, design requirements and installation for communications

More information

Cable ladder installation at S.C.M. Chemicals Limited s titanium dioxide Plant in Western Australia

Cable ladder installation at S.C.M. Chemicals Limited s titanium dioxide Plant in Western Australia Exel Composites Cable Support Systems offer engineers a structural product for solving many design and plant engineering problems, enabling long term reliable support of expensive and often critical cables.

More information

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED SQUARE TUBE LADDER

More information

SECTION 260536 - CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system.

SECTION 260536 - CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system. SECTION 260536 - CABLE TRAYS PART 1 - GENERAL SECTION INCLUDES: A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system. B. Cable tray systems are defined to include, but

More information

Cable Support Solutions

Cable Support Solutions Cable Support Solutions B-Line by Eaton Technology Day Japan 2013 2012 Eaton Corporation. All rights reserved. 2012 Eaton Corporation. All rights reserved. 2012 Eaton Corporation. All rights reserved.

More information

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate: Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,

More information

SECTION 4: Cable Ladder Stainless Steel & Aluminium

SECTION 4: Cable Ladder Stainless Steel & Aluminium SECTION 4: Cable Ladder & Aluminium Type 3/50 (NEMA 6A) Type 4/70L Type 5/112 (NEMA 20C) > 4:3 > 4:4 > 4:5 Aluminium Type 4/70A (NEMA 16B) Ladder Splice Plates > 4:7 > 3:18 Page 4:1 Cable Ladder General

More information

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel

More information

TCTC Cabling Specifications

TCTC Cabling Specifications TCTC Cabling Specifications Purpose: To provide a standard specification that will be used for all Tri County Technical College (TCTC) facilities requiring structured cabling installation. Product specifications,

More information

Cable/Conduit Conversion

Cable/Conduit Conversion Cable/Conduit Conversion Busway can be used in many applications where cable and conduit are more commonly used. The question arises, Why use busway instead of conventional cable and conduit? Benefits

More information

Whitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada

Whitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada Whitepaper Modular Substation Cable Termination Design Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada Abstract The methods for cable penetrations into modular industrial substations are

More information

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO WHEN YOU HEAR AN ENGINEER SAY A NUMBER OF DIFFERENT APPROACHES ARE BEING IMPLEMENTED

More information

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements 16600 Underground Electrical Duct Bank This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications

More information

AN IN-DEPTH LOOK AT 2011 NEC ARTICLE 392 - CABLE TRAY. (The following code explanations are to be used with a copy of the 2011 NEC.

AN IN-DEPTH LOOK AT 2011 NEC ARTICLE 392 - CABLE TRAY. (The following code explanations are to be used with a copy of the 2011 NEC. AN IN-DEPTH LOOK AT 2011 NEC ARTICLE 392 - CABLE TRAY (The following code explanations are to be used with a copy of the 2011 NEC.) To obtain a copy of the NEC contact: National Fire Protection Association

More information

AMPSEAL* Automotive Plug Connector and Header Assembly

AMPSEAL* Automotive Plug Connector and Header Assembly AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2

More information

TARIFF CODE and updates standard

TARIFF CODE and updates standard TARIFF CODE and updates standard No HS CODE AHTN CODE PRODUCT DESCRIPTION PRODUCT TYPE STANDARDS IDENTIFIED 7207 Semi finished products of iron or non alloy steel Containing by weight less than 0.25% of

More information

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2

More information

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service

More information

PART 1 GENERAL 1.1 SECTION INCLUDES

PART 1 GENERAL 1.1 SECTION INCLUDES J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including

More information

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL

More information

Chapter 3 Pre-Installation, Foundations and Piers

Chapter 3 Pre-Installation, Foundations and Piers Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory

More information

CABLE SUPPORT SYSTEMS

CABLE SUPPORT SYSTEMS CABLE SUPPORT SYSTEMS eaturing the CADDY CAT HP J-Hook System Why CADDY CAT HP? Why Choose CADDY CAT HP over tray? ast and Easy to Install Much faster installation compared to conventional cable or ladder

More information

Cat. No. Material Siderail Height. Designed to lock into place for easy alignment and installation. ABW-4-SSP

Cat. No. Material Siderail Height. Designed to lock into place for easy alignment and installation. ABW-4-SSP Metallic Snap-In Splice Plate Designed to lock into place for easy alignment and installation. Packaged in pairs with zinc plated hardware. Provided as standard with each straight and fitting. Cat. No.

More information

SYSTEM 1850-SE SERVICE ENTRANCE CABLE SYSTEM

SYSTEM 1850-SE SERVICE ENTRANCE CABLE SYSTEM Pyrotenax SYSTEM 1850-SE SERVICE ENTRANCE CABLE SYSTEM Contents Introduction This section provides an overview of general circuit design considerations and installation guidelines for a Pyrotenax System

More information

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS RELATED SECTIONS: Section 27 00 00 General Requirements Section 27 02 00 Communication General Requirements Section 27 05 28 Pathways for Communications

More information

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables The National Armored Cable Manufacturers Association Presents Installation Standard for Types AC and MC Cables An ANSI Standard Original document jointly produced by NECA and NACMA as Standard for Installing

More information

Power Plant Electrical Distribution Systems

Power Plant Electrical Distribution Systems PDH Course E184 Power Plant Electrical Distribution Systems Gary W Castleberry, PE 2008 PDH Center 2410 Dakota Lakes Drive Herndon, VA 20171-2995 Phone: 703-478-6833 Fax: 703-481-9535 www.pdhcenter.com

More information

Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS

Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS TABLE OF CONTENTS I. RULES AND REGULATIONS A. TABLE OF CONTENTS... 2 B. TERMS AND DEFINITIONS... 3 C. DEVELOPER S/CONTRACTOR S RESPONSIBILITIES...

More information

Cable Runways & Accessories

Cable Runways & Accessories SB17U SB13AL SB17 SB17T SB117 SB17HRB SB2107 SB2101A SB17VRB SB2110A SB2129 SB2129SD SB130 SB2221 SB126 SB2118 SB119 SB2105 113 Cooper B-Line manufactures a wide variety of high quality cable pathway products

More information

REQUIREMENTS AND SPECIFICATIONS FOR HIGH VOLTAGE CUSTOMER BUILT FACILITIES PEPCO ENGINEERING

REQUIREMENTS AND SPECIFICATIONS FOR HIGH VOLTAGE CUSTOMER BUILT FACILITIES PEPCO ENGINEERING REQUIREMENTS AND SPECIFICATIONS FOR HIGH VOLTAGE CUSTOMER BUILT FACILITIES PEPCO ENGINEERING Revised October, 2013 TABLE OF CONTENTS 1.0 INTRODUCTION... 3 2.0 REQUIRED DRAWINGS... 3 2.1 Site Plan... 3

More information

Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks

Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks Introduction This document presents the fundamental aspects of cable and conductor selection for connecting pad mounted shunt

More information

Generator DoCKInG StatIonS

Generator DoCKInG StatIonS Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed

More information

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2

More information

CABLE TRAY MANUAL Based on the 2011 National Electrical Code

CABLE TRAY MANUAL Based on the 2011 National Electrical Code 2011 CABLE TRAY MANUAL Based on the 2011 National Electrical Code MAN-1 Table of Contents Page No. Introduction... MAN-3 Why Cable Tray? Safety... MAN-4 Dependability... MAN-4 MAN-5 Space Savings... MAN-5

More information

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS) August, 2009 Vertical Break Parallel (VBP) / Vertical Break Slant (VBS) Type VBPA (Aluminum) / Type VBPC (Copper) Type VBSA (Aluminum) / Type VBSC (Copper) PASCOR Air Break Switch Technology PASCOR offers

More information

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both

More information

EHV CONNECTORS EHV TERMINALS ACFS (EHV)... ALUMINUM BOLTED TUBE TO FLAT PAD, SHORT...EHV-7

EHV CONNECTORS EHV TERMINALS ACFS (EHV)... ALUMINUM BOLTED TUBE TO FLAT PAD, SHORT...EHV-7 CONNECTORS TERMINALS ACF ()... BOLTED TUBE TO FLAT PAD...- ACFS ()... BOLTED TUBE TO FLAT PAD, SHORT...-7 CCL-... COMPRESSION TUBE TO FLAT PAD...- CCLS-... COMPRESSION TUBE TO FLAT PAD, SHORT... - EVKET...

More information

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS STANDARD & ECONOMICAL BasicRack A complete low-cost, high-quality basic equipment management system. Design Six web channel holes per side allow

More information

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation Basis of Design This section applies to the design relating to low voltage switchboards. Design Criteria UW Class N1 facilities main switchboards shall be rear accessible. The main, tie and feeder breakers

More information

SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes seismic restraints and other earthquake-damage-reduction measures for electrical

More information

Guidelines for Earthquake Bracing of Residential Water Heaters

Guidelines for Earthquake Bracing of Residential Water Heaters Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)

More information

MOBILE HOME SERVICE REQUIREMENTS GAS

MOBILE HOME SERVICE REQUIREMENTS GAS ELECTRIC AND GAS 1.0 INDEX 1.0 INDEX 2.0 PURPOSE 3.0 GENERAL 4.0 REFERENCE MATERIAL 5.0 TYPICAL UNDERGROUND UTILITY LAYOUT 6.0 METER PAD DETAILS 7.0 GENERAL INSTALLATION PROCEDURES 8.0 PEDESTAL SPECIFICATIONS

More information

CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute

CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute Cable Tray Wiring Systems Have Many Cost Advantages Cost is usually a major consideration in the selection of a wiring system.

More information

ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24, 2014 06610-1

ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24, 2014 06610-1 ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING January 24, 2014 06610-1 SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS MOLDED GRATING PART 1 - GENERAL 1.1 SCOPE OF WORK A. The CONTRACTOR

More information

4 Installation Requirements

4 Installation Requirements 4 Installation Requirements 9 4.1 Code Reference The authority having jurisdiction should be referenced to determine what law, ordinance or code shall apply in the use of flexible duct. Ducts conforming

More information

SECTION 02630 STORM DRAINAGE SYSTEM

SECTION 02630 STORM DRAINAGE SYSTEM SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE

More information

TS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING

TS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING TORONTO TRANSPORTATION January 2012 TS 813 GROUNDING AND BONDING TABLE OF CONTENTS 1. DRAWINGS TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET

More information

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Built to Last. Built for Beauty. Good. Solid. Logix. TM Built to Last. Built for Beauty. Good. Solid. Logix. TM Quality, Value and Service Introducing LOGIX Insulated Concrete Forms. Based on the simple concept of interlocking blocks, LOGIX ICF gives you a

More information

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp Page 1 2015 Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other Component 15 kv or 25 kv Separable Insulated Connector (elbow) Equipment Connection Power Cable Power Cable Grounded Metal

More information

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. July 1, 2008 Revision 2

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. July 1, 2008 Revision 2 ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES 1 PART 1 - GENERAL 1.0 GENERAL 1.1 REFERENCES: SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED FIBERGLASS

More information

Preformed Metal Roofing and Siding

Preformed Metal Roofing and Siding Page -1-1. GENERAL 1.1. Description This specification along with the drawings covers the furnishing of all material, products, equipment, accessories, tools, services, transportation, labor and supervision

More information

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

ELECTRIC METERING COMMERCIAL & INDUSTRIAL ELECTRIC METERING COMMERCIAL & 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 METER LOCATIONS 5.0 UNDERGROUND TERMINATIONS 6.0 METERING TRANSFORMER ENCLOSURES 7.0 SINGLE CUSTOMER METER INSTALLATIONS

More information

60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING 60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed

More information

Safely Installing, Maintaining and Inspecting Cable Trays

Safely Installing, Maintaining and Inspecting Cable Trays Purpose U.S. Department of Labor Occupational Safety and Health Administration Directorate of Technical Support & Emergency Management Office of Technical Programs and Coordination Activities Safely Installing,

More information

Sample - No Commercial Use

Sample - No Commercial Use COMPLETE REVISION October 2010 Electrical PIP ELSSG01 Design and Fabrication of Low-Voltage Metal-Enclosed AC Power Circuit Breaker Switchgear PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort

More information

SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS

SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials

More information

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application Product overview brochure ABB Medium Voltage Products Our one-stop approach for every medium voltage application Overview ABB meets every need for reliable, safe and energy-efficient medium voltage switchgear,

More information

KNOW YOUR OPTIONS: 230 KV POWER CABLES

KNOW YOUR OPTIONS: 230 KV POWER CABLES KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common

More information

CDGRD-10. Grounding. Solutions For Comm/Data Applications

CDGRD-10. Grounding. Solutions For Comm/Data Applications CDGRD-10 Grounding Solutions For Comm/Data Applications Overview & Table of Contents Cooper B-Line s Grounding products for rack & runway provide a complete solution for grounding metal supports. The offering

More information

Scepter PVC Molded Junction Boxes

Scepter PVC Molded Junction Boxes Scepter PVC Molded Junction Boxes ELECTRICAL SYSTEMS PVC MOLDED JUNCTION BOXES 4" to 12" We build tough products for tough environments Standing Still is Not an Option. We re proud to introduce the NEW

More information

IRRIGATION PUMPING Table of Contents - Section 900

IRRIGATION PUMPING Table of Contents - Section 900 IRRIGATION PUMPING Table of Contents - Section 900 PARAGRAPH 900.1 GENERAL 1 900.2 METERING REQUIREMENTS 1 900.3 CUSTOMER S CONTROL EQUIPMENT 2 900.4 SERVICE CONDUCTOR REQUIREMENTS 2 900.5 RECOMMENDATIONS

More information

SECTION 15140 - PIPE HANGERS AND SUPPORTS

SECTION 15140 - PIPE HANGERS AND SUPPORTS Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the

More information

PTFE Slide Bearings 04/10 149

PTFE Slide Bearings 04/10 149 04/10 149 1.0 GENERAL INFORMATION In a wide range of applications, PTFE Slide bearings are superior to conventional expansion plates, rollers and rocker arm type supports. They support petrochemical plant,

More information

Secondary Unit Substations

Secondary Unit Substations 14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically

More information

IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality

IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION Generated: Sergiy Papyshev Engineering Approved: Don Prysi Manufacturing Approved: Merzuk Ramic Quality Approved: Steven Barnett Administrative DATE DATE DATE

More information

Light Duty Commercial Electric Water Heater

Light Duty Commercial Electric Water Heater Features Heavy Duty Construction Hydrastone cement lining provides longer tank life Copper-silicon tappings cannot rust or corrode High impact composite jacket eliminates damage during installation and

More information

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables

GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables Engineering Department SEPTEMBER, 2007 GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables General Requirements This section applies to all public and private utilities,

More information

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS 1. SCOPE 1.1 This specification covers the type, physical properties and dimensions of Expanded Polystyrene Insulation Board intended for use

More information

Guidelines for Earthquake Bracing Residential Water Heaters

Guidelines for Earthquake Bracing Residential Water Heaters Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the

More information

Cooktop Low-Profile Ventilation Hoods

Cooktop Low-Profile Ventilation Hoods INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............

More information

Session 14 Cable Support Systems

Session 14 Cable Support Systems Session 14 Cable Support Systems Cable Support Systems in the IEC World A new IEC Standard, IEC61537 2001 has been developed If full details of the cabling layout are available then the likely cable load

More information

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4 CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,

More information

WHY CABLE TRAY? BECAUSE A CABLE TRAY WIRING SYSTEM PROVIDES SAFE AND DEPENDABLE WAYS TO SAVE NOW AND LATER

WHY CABLE TRAY? BECAUSE A CABLE TRAY WIRING SYSTEM PROVIDES SAFE AND DEPENDABLE WAYS TO SAVE NOW AND LATER Large numbers of electrical engineers have limited detail knowledge concerning wiring systems. There is the tendency by engineers to avoid becoming involved in the details of wiring systems, leaving the

More information

The RIGHT SOLUTIONS for Canada s Oil and Gas Industry. T&B Cable Tray Systems

The RIGHT SOLUTIONS for Canada s Oil and Gas Industry. T&B Cable Tray Systems The RIGHT SOLUTIONS for Canada s Oil and Gas Industry T&B Cable Tray Systems What if you could get all the right solutions from one reliable Canadian source? Engineers, contractors and end-users working

More information

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS Prepared by: ABB1 ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS 052521 Asset Type: Electric Metering Function: Construction Issued by: Quoc Hoang (QxH1) Date: 07-01-16 Rev. #06: This document

More information

Section 5 161 kv Power Cables

Section 5 161 kv Power Cables Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper

More information

CLEAR-DIVISIONS CENTERFOLD

CLEAR-DIVISIONS CENTERFOLD CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in

More information

Commercial Gas Furnace Upflow

Commercial Gas Furnace Upflow Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted

More information

PRO PANELS. 1-800-525-4159 www.propanels.com. the artist s choice in display designed by artists, for artists. voice: 214-350-5765 fax: 214-350-7372

PRO PANELS. 1-800-525-4159 www.propanels.com. the artist s choice in display designed by artists, for artists. voice: 214-350-5765 fax: 214-350-7372 PRO PANELS by MD Enterprises the artist s choice in display designed by artists, for artists 1-800-525-4159 www.propanels.com voice: 214-350-5765 fax: 214-350-7372 MD Enterprises 1-800-525-4159 voice:

More information

James M. Pleasants Company

James M. Pleasants Company James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:

More information

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage: Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial

More information

SECTION 18370 SIGNAL WIRE AND CABLE

SECTION 18370 SIGNAL WIRE AND CABLE SECTION 18370 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for all cable and wire required for signal and signal power system wiring to wayside shelters, junction boxes, and factory

More information

Please check with your local inspection authority for any additional requirements before installation.

Please check with your local inspection authority for any additional requirements before installation. Specifications for Residential Overhead Electric Service Installation This brochure addresses most typical residential overhead service installations. Variances for the following specifications must be

More information

Installation Instructions For Slider Casement Air Conditioners

Installation Instructions For Slider Casement Air Conditioners Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT

More information

INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION

INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION February 2013 NOTE: If conflict exists between St. Thomas Energy s Conditions of Service and this document, the Conditions

More information

Hyperlinks are Inactive

Hyperlinks are Inactive Prepared by: NIB/EOB PLANNING GUIDE FOR SINGLE CUSTOMER SUBSTATIONS SERVED FROM TRANSMISSION LINES 05503 Department: Electric T&D Section: T&D Engineering and Technical Support Approved by: G.O. Duru (GOD)

More information

Electrical Service Guidelines

Electrical Service Guidelines Electrical Service Guidelines Middle Tennessee Electric Membership Corporation Revised: May 23, 2013 MTEMC's Electrical Guidelines TABLE OF CONTENTS Right-of-Way Clearance Guide 3 MTEMC Requirements 4

More information

This presentation to be used in conjunction with:

This presentation to be used in conjunction with: 1 This presentation to be used in conjunction with: Spec Sheets: SA-GRSP10, SA-GRSP09, SA-GRSP11 Samples in DC-GROUND-KIT 8/16/2012 2 Network Bonding and Grounding: TIA-607-B Generic Telecommunications

More information

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings

More information

San Antonio Water System Standard Specifications for Construction ITEM NO. 1100 SLIP-LINING SANITARY SEWERS

San Antonio Water System Standard Specifications for Construction ITEM NO. 1100 SLIP-LINING SANITARY SEWERS ITEM NO. 1100 SLIP-LINING SANITARY SEWERS 1100.1 DESCRIPTION: This item shall consist of slip-lining sanitary sewer pipe, which is accomplished by pulling or pushing liner pipe into existing sewers by

More information

SECTION 05 7360 ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS

SECTION 05 7360 ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS 1 SECTION 05 7360 ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and

More information

ONTRAC WIRE MESH CABLE TRAY SYSTEM

ONTRAC WIRE MESH CABLE TRAY SYSTEM P R O D U C T D ATA S H E E T ONTRAC WIRE MESH CABLE TRAY SYSTEM K E Y F E AT U R E S Available in two styles: Shaped and Standard Tray Easy to use pathway solution that supports large quantities of network

More information

ATS Overhead Table Shelf System INSTRUCTION MANUAL

ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship

More information

ASME Packaged Indirect Fired Water Heater

ASME Packaged Indirect Fired Water Heater Utilizes Or HTHW To Heat Domestic Water, Semi-Instantaneous or Storage Type Model BW Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining

More information