1 Nivåvakt Typ Miniflottör The specialist of finding all your needs and solutions. The Best Choice and Perfect Answer. wallox Telefon: Telefax:

2 PRODUCT INTRODUCTION 4 INTRODUCTION 4 PRIIPE Since technologies of the product have more and more advance, the products need comply with a requirement for more convenient, safe and low cost. The float switches are extremely compact, simple and are easy to install on any small space. These switches are not effected by electrical interference. They can withstand to chemicals, high temperatures and pressures if the correct material of float switch is selected by the customers. Fig. illustrates the method of pivot actuation (such as the FCH TYPE float switches). When the magnetic field of permanent magnet inside the float is moved into to the proximity of the reed switch inside the stationary stem, the reed switch "snaps" the contact together and closes the electrical circuit. When the magnetic field is moved away from the reed switch, the reed switch does not touch. The circuit is open. 4 IQUID PROPERTIES AND FOATS When the liquid specific gravity is less or more than the water, the float on the switch will either increase or decrease the iersion depth. The switch actuation level will also change. All actuation levels are assumed with the water (SG=). If your liquid has a different specific gravity, you should not specify the float specific gravity more than liquid, that will not cause the float rise with the liquid level. The reed switch inside the stationary stem will not be activated by the magnet inside the float. If your liquid has a high viscosity, you should specify largest size float that will provide a greatest buoyant force to ensure the units operate normally. Because the float switches are activated by the magnetic field of permanent magnet inside the float, make sure the liquid is no iron powder or magnetic material to avoid magnetic interference. closed S N magnet open (Fig. ) Fig. 2 illustrates the method of perpendicular actuation (such as the FC V TYPE float switches). When the magnetic field of ring magnet inside the float is moved into the proximity of reed switch inside the stationary stem, the reed switch "snaps" the contact together and closes the electrical circuit. When the magnetic field is moved away from the reed switch, the reed switch does not touch. The circuit is open. Ring SG=0.9 SG= S S N N S3 (Fig. 3) Reed switch open (OFF) Reed switch closed (ON) (Fig. 2) Telefon: Telefax:

3 REED SWITCH PROTECTION 4 INDUCTIVE OADS When using reed switches for inductive loads such as motors, relay coil, solenoids, etc., the contacts will be subjected to high induced voltages during opening of the contacts (load circuit). Such high induced voltages (transients) may cause damage to the reed switch or significantly reduce its life. Therefore, protective circuits such as: RC (snubber), varistor or clamping diodes are recoended. (see Fig. 4a, Fig. 4b, Fig. 4c) 2 C= I (uf) 0 R= E E 0I(+ 0 ) H AC C N R (RC) 4 It is prohibited to drive directly solenoid valve, Fig. 4 (a) motor or magnetic switch. H F AC DC G N (Varistor) (Diode) Fig. 4 (b) Fig. 4 (c) 4 CAPACITIVE OADS When using reed switches for capacitive loads such as capacitors, incandescent lamps or long cables, the contacts will be subjects to high surge (inrush) current. Therefore, protective circuits such as: surge suppressors or current limiting resistors are recoended. (Fig. a, Fig. b) C R E(V) R E(V) Fig. (a) Fig. (b) Telefon: Telefax:

4 FOAT SPECIFICATIONS MODE A B C A B C A B TYPE faxbxfc S.G. S E>0.7 0 S3 433 E>0.6 S S2 Max. Pressure Weight 2 (kg/cm ) (g) Material/Color Max. Temp. (C) 8 SUS 304 / SUS E> SUS E> SUS S E> SUS S E> SUS S E> SUS 304 / S E> SUS S E> SUS S E> SUS P 2330 E> PP / white black 80 P E>0. 4 PP / white black 80 P E> PP / black 80 P E> PP / black 80 P E> PP / black 80 P E> PP / black 80 Q E>0.7 ATM 3. PP / white 80 Q E>0.7 ATM 6.7 PP / white 80 N 2330 E>0. ATM 2.7 NBR / black 00 N E>0.7 ATM 3.3 NBR / black 00 N E>0. ATM 2.4 NBR / black 00 N E>0.6 ATM 2. NBR / black 00 N E>0. ATM. NBR / black 00 F E> PP 80 F E> PP 80 F E> PVDF 20 C (Hollow) A B C (Foam) A B C (Hollow) Telefon: Telefax:

5 META SINGE SWITCH TYPES FD MH0A /6A ead wire: 2m f7 47 f7 9 6 ead wire: FD MH0C /6C 47 f7 FD MH0/ 6 FD MH60A/ 66A f Hex26 /2"PT 36B 68 36B Hex26 /2"PT 36B 32 Hex26 /2"PT 36 7 f7 f7 ead wire: 9 6 2m B FD MH60C/ 66C ead wire: Hex26 /2"PT Hex26 /2"PT FD MH60/ B 3B 32 Hex26 /2"PT 4 SPECIFICATIONS Type FDMH0/6 FDMH60/66 Material Switching Switching Switching Capacity Voltage Current Max. Max. Max. Carry Current Max. ead Wire Max. Pressure Operating Temp. Suitable Sp. Gr. -20~20C FDMH:0.92 (Max.200C) FDMH6:0.7 SUS Vac 0W/SPST 200Vdc SUS 36 0.A A XPE or TEFON kg/cm2 FDMH0A/6A SUS Vac 0W/SPST FDMH60A/66A SUS Vdc 0.A A XPE or TEFON kg/cm2 80C FDMH:0.92 FDMH6:0.7 FDMH0C/6C SUS Vac 0W/SPST FDMH60C/66C SUS Vdc 0.A A XPE or TEFON kg/cm2-20~20c FDMH:0.92 FDMH6:0.7 Telefon: Telefax:

6 ORDER INFORMATION FOR META SINGE SWITCH TYPES FDMH 0 A B R ( 0 F) Type : f7x47 (SG: 0.92) 6: f7x7 (SG: 0.7) Material 0: SUS304 6: SUS36 Connection G : without, A: ASI, C: DIN Connecting Type BR:/2"PF, BQ: /2"PT, BU: /2"NPT, BT: /2"BSP ead wire ength (Unit=00) 0: 00 (below 00) 0: 000 (0~000) : 00 (00~00) 00 per Unit 300 (Standard length) Material of ead wire F: SIICON (200C) T: TEFON (200C) X: XPE (2C) AWG24 X f4 AWG24 AWG22 (Standard) Material of Wetted parts"sus304" Telefon: Telefax:

7 META TYPES ead wire: ead wire: ead wire: /8" PF Hex f4 f28 Hex2 Hex Hex 7 3/8" PF ead wire: 3/8" PF /8" PF FD 49 FD 409 FD 309/ FD 39 f30 f 9. f 4 Drill hole f0 M4x0.7 M4x0.7 f2.7 Drill hole f7 FD 3092 Drill hole f7 FD 4092 FD Hex 7 80 Hex 2 3/8"PF 8 3/8"PF Hex2 /8"PF f9. f4 f28 Drill hole f0 M4x0.7 f2.7 M4x0.7 f4 Drill hole f7 Telefon: Telefax: Drill hole f7

8 META TYPES FD 09 FD 092 FD 79 ead wire: ead wire: 3/8" PF /2" PF Hex2 Hex /8" PF Hex f2.7 f2 M4x0.7 Drill hole f7 f7.2 f 7 M4x0.7 f2.7 f 2 Drill hole f7 Drill hole f2 4 SPECIFICATIONS Description FD309D FD3092D Switching Capacity Max. 0W SPST Type Switching Voltage Max. Switching Current Max. (A) Carry Current Max. (A) FD409D FD4092D 0W SPST 0W SPST FD09G 60W SPDT 220Vac 0.A 0.A 0.A 2A A A A A 3A XPE (U3266, AWG22) YES / below 80C, / UP 80C 0 30 Operating Temperature ~20C (OPTION 200C) Material 0W SPST FD79G 0.A Reversible Switch Action Suitable Specific Gravity FD09D FD092D 240Vac/200Vdc Max. Pressure (Kg/cm2) FD49D FD492D Stainless Steel SUS304, Telefon: Telefax:

9 PASTIC OH TYPES 4 Installation / N.C./ N.O. Action Position FCHQD Drill hole f2. Wall Thickness Max. Normally open N.O. Normally closed N.C. Reed Switch 4 Hex Reed Switch 97 f3 M2x.2 All the products in this range come with the U E687 approval. 0 2 All the products in this range are designed to be mounted on the side. For the specific gravity of water is used as a reference point in calculating specific gravity. 4 SPECIFICATIONS Description Type FCH2PD FCH3PD FCHQD Switching Capacity Max. FCH2GD FCH3GD 240VAC / 200Vdc Switching Current Max. (A) 0.A A Carry Current Max. (A) Max. Pressure (Kg/cm2) FCH24YD FCH34YD 0W SPST Switching Voltage Max. FCH23FD FCH33FD PVC AWG22 XPE AWG22 4 kg/cm2 ATM Operating Temperature 2 kg/cm2-20~20c -20~80C Material PP PVDF Nylon Polysuphone Suitable Specific Gravity Weight 2 g H2: 22 g H3: 2 g 2 g 23 g 2.4 g Telefon: Telefax:

10 PASTIC OH TYPES FC H2PD / H3PD For models FCH2 and FCH3, three different types of material are available PP, Nylon, and PVDF. The special lead wire or cable can be supplied according to the requirement of the customer. The customer can select the type of reed switch which their requires. For specifications of the standard design see catalog ( page 0). OEM customers are welcome. 4 Installation / N.C. / N.O. Action Position 4 Optional FC H2PDO(Round) [ External mounting ] 90 Arrow Downward Normally Closed 2 M6 Hex24 4B 43. f2 Drill hole f2+0.2 f 7 EPDM 23B PP Washer 27. N.C. function, i.e. the contact opens when the liquid level rises. Max. 6 4 Standard FC H2PDD (Hexagon) [ Internal mounting ] 90 Arrow Upward Normally Open 2 (Option) 43 Hex22 Drill hole f6 f 7. M6 Hex24 EPDM Parking PP washer 4 7 B NBR Washer 22. N.O. function, i.e. the contact closes when the liquid level rises. 4 FC H3PD [ External mounting ] 97. Hex8 7 f 7. /2"PT 4B Telefon: Telefax:

11 PASTIC OH TYPES 4 Installation / N.C. / N.O. Action Position FC H4PD / HPD OFF ON ON OFF 4 FC H4PD 02 B f7. B /2"PT 2 0 N.O. function, i.e. the contact closes when the liquid level rises. 4 FC HPD B 6 30 B Hex8 42 /2"NPT 4 FC H6PD 20 0 N.C. function, i.e. the contact opens when the liquid level rises. 20 M6x2 : f Hollow Float 42 f2 4 SPECIFICATIONS Type Switching Switching Switching Carry Material Capacity Voltage Current Current Max. Max. Max. Max. ead Wire 240Vac 200Vdc XPE FCH4PD FCHPD FCH6PD PP 0W/SPST 0.A A Operating Suitable Max. Sp. Gr. Pressure Temp. Telefon: Telefax: kg/cm2-20~80c Weight 20g 2g 3g

12 PASTIC OV TYPES FC VQF FC V2QD FC V3PD : : 4 Foam Float material: PP Foam Float material: PP 2 f 6. f 20 f 2 Drill hole f0 Drill hole f0 Hex Hollow Float 44 2 Hollow Float Hex20 Hex7 /8" PF /8" PF : : /8" PF /8" PF FC V33FD, 34YD, 3GD 26.8 f 2 f 2 O-ring: VITON Drill hole f0 O-ring: VITON Drill hole f0 4 SPECIFICATIONS Description Type Switching Capacity Max. Switching Voltage Max. FC VQF FC V2QD 0W SPST 0W SPST 2Vac 240Vac / 200Vdc Switching Current Max. (A) Carry Current Max. (A) Reversible Switch Action 0W SPST 240Vac / 200Vdc 0.A 0.A A A U 007 AWG22 PVC FC V3PD FC V33FD FC V34YD FC V3GD U 007 AWG22 PVC XPE AWG22 YES/ 80C down YES/ 80C down Max. Pressure (Kg/cm2) ATM 4 kg/cm2 2 kg/cm2 Operating Temperature -20~80C -20~80C -20~20C Material PP PP PVDF Nylon Polysuphone Suitable Specific Gravity g 8 g g 8 g Weight (g) 2 g 8 g Telefon: Telefax:

13 PASTIC OV TYPES FC V4PD, V4QD FC VNF FC V6PF, V6NF : /8" PF : 28cm : /8" PF M6x2 Hex24 33 EPDM Parking Hex7 Foam Float material: NBR f V4PD: Hollow Float material: PP V4QD: Foam Float material: PP f 6. f9 V6PF: Hollow Float Material: PP V6NF: Foam Float Material: NBR 48 2 f 2 Drill hole f0 FC V8PD Drill hole f6 Drill hole f0 FC V4ND FC VPD : 28cm : M6 M8 M6x Hollow Float material: PP 77 4 f f 48 Drill hole f6 2. Hex24 0 Hex2 Hex Hollow Float material: PP Foam Float material: NBR Drill hole f6 Telefon: Telefax: O-Ring: VITON Drill hole.

14 PASTIC OV TYPES 4 SPECIFICATIONS Type Description Switching Capacity Max. Switching Voltage Max. FC V6PF FC V6NF FC VNF FC V4PD FC V4QD 0W SPST 2Vac (Break Down 20Vac) 240Vac / 200Vdc 0.A Carry Current Max. (A) Reversible Switch Action Max. Pressure (kg/cm2) FC V4ND FC VPD 0W SPST Switching Current Max. (A) FC V8PD A XPE AWG22 U 007 AWG22 PVC YES V6P: 4kg/cm V6N: ATM ATM Operating Temperature 2 V4P: 4kg/cm V4Q: ATM 4 kg/cm2 ATM 4 kg/cm ~00C -20~80C Material PP (except VN, V6N, V4N: NBR float) Suitable Specific Gravity Weight (g) g 6 g 23 g 80 g 7 g 8.2 g OV2 OV4 OV OH2 OV6 OH Telefon: Telefax:

15 ORDER INFORMATION FOR PASTIC OH/OV TYPES FC V 2 3 F D A ( 0 P) Order No./ Model FC H~H6: RF-OH Side Mounting FC V~V9 : RF-OV Top or bottom Mounting Material of Wetted parts : PP 3 : PVDF 4 : Nylon : Polysuphone 6 : PPS Material of Float F :PVDF P : PP (hollow) K : PPS N : NBR Q: PP (foam) G :Polysuphone Y : Nylon (Unsuitable for use in water application for long term) Switching Capacity Max. D : 0W 240Vac /200Vdc SPST F : 0W 2Vac SPST K : 20W 0Vac/200Vdc SPDT Contact Form A: Normally Open (N.O.) SPST B: Normally Close (N.C.) SPST C: AB SPDT D: Reversible E : Reversible ead wire ength (Unit=00) 00 per Unit 300 (Standard length) 좪좪좪 0: 00 (below 00) 0: 000 (0~000) : 00 (00~00) Material of ead wire B: PVC (80C) C: PVC cable (80C) D: XPVC (0C) F : SIICON cable (200C) P : PVC (80C) T : TEFON (200C) X : XPE (2C) S : Others AWG24 AWG22 X f4 AWG24 AWG24 X f4 AWG22 AWG24 AWG22 "A" (Normal Open) contact form is our standard specified switch activation, others contact form and target lead wire length subject to above data, except of above, please refer pages 6, 7, 9, 0and 2. Telefon: Telefax:

16 PASTIC SPECIA TYPES FC PV PVC FC PV2 : PVC /8" PF Hex20 Foam Float material: PP PVC : /8" PF FC PV3 Hex20 /8" PF Hex20 : (Max.) Foam Float material: PP Foam Float material: PP 2 f 2 f 2 O-Ring: VITON (Max.) (Max.) 2 f 2 O-Ring: VITON O-Ring: VITON TE: Float material can be optional. Above items are done by custom-built when the standard specification is unable to be coped with their unique demand. There are with below special benefits: FCPV One float for one level activation switch location by custom-order. FCPV2 One float with 2 reed switches, applicable for high / low two level activation, especial design by one float to drive two contacts activation. FCPV3 Two floats drive with two independent reed switches, the compared difference with FCPV2 base on below character : Each one float unit can be performed by N.O. or N.C. level activation as per customer's option. Telefon: Telefax:

17 ORDER INFORMATION FOR PASTIC SPECIA TYPE FC P V 2 D A ( 0 P ) Order No./ Model PV: RF-PV Vertical Mounting, Single Float Single Switch PV2: RF-PV2 Vertical Mounting, Single Float Dual Switch PV3: RF-PV3 Vertical Mounting, Dual Float Dual Switch Material of Wetted parts : PP; ead wire---pvc---temp. 80C 2 : NBR (only float); ead wire---pvc---temp. 60C ead wire---xpe---temp. 00C 3 : PVDF; ead wire---xpe---temp. 2C 4 : Nylon; ead wire---xpe---temp. 2C (Unsuitable for use in water application for long term) Switching Capacity Max. D: 0W 240Vac /200Vdc SPST F : 0W 2Vac SPST K: 20W 0Vac/200Vdc SPDT Contact Form A: Normally Open (N.O.) SPST B: Normally Close (N.C.) SPST C: SPDT F: float 2 points. H: -N.O.,-N.C.(2 floats) ead wire ength (Unit=00) 0: 00 (below 00) 0: 000 (0~000) : 00 (00~00) 00 per Unit 300 (Standard length) Material of ead wire C: PVC cable (80C) P : PVC (80C) X : XPE (2C) ---- AWG22 X f AWG22 (Standard) ---- AWG22 Telefon: Telefax:

18 ORDER INFORMATION FOR META TYPE FD D A ( 0 H) Order No./ Model 0 Float : f7x08, Screw : /2"PF 30 Float : f28x28, Screw : /8"PF 3 Float : f28x28, Screw : /8"NPT 3 Float : f30x28, Screw : /8"PF 36 Float : f30x28, Screw : /8"NPT 40 Float : f4x38, Screw : 3/8"PF 4 Float : f4x, Screw : 3/8"PF 0 Float : f2x2, Screw : 3/8"PF 7 Float : f7x70, Screw : /2"PF Material of Wetted parts 0 : SUS304 6 : SUS36 Mounting : Top or Bottom Mounting 2 : Side Mounting Switching Capacity Max. D: 0W 240Vac /200Vdc SPST F : 0W 2Vac SPST G: 60W 220Vac SPDT (only use for tude ]f2.7) S: Others Contact Form A: Normal Open (N.O.) SPST B: Normal Close (N.C.) SPST C: C SPDT D: N.C. Reversible E: N.O. Reversible High Temp only available for A or B Type ead wire ength (Unit=00) 00 per Unit 300 (Standard length) 좪좪좪 0: 00 (below 00) 0: 000 (0~000) : 00 (00~00) Material of ead wire B: PVC cable (80C) C: PVC cable (80C) D: XPVC (0C) F : SIICON cable (200C) P : PVC (80C) T : TEFON (200C) X : XPE (2C) High Temp. (200C) AWG24 AWG22 X f4 AWG22 AWG24 X f4 AWG22 AWG24 AWG22 (Standard) Telefon: Telefax:

19 META SPECIA TYPES Below items are custom-built subject to special application place and existed equipment facilities. Their unique characters as follow: Customized mounting thread specification are acceptable. Single or multiple contact form (point) are workable. Any size measuring range, but stem Max. 00. Switch activation N.O. or N.C. are available. FDSB9 FDSA9 FDSC9 : : : /8" NPT M2 /8" PF Hex f f 28 f 28 FDSA92 FDSA92 FDSA922 : 4 /8"PF Hex7 X(min=4) 60 Hex7 2 /8" PF f f 28 f 28 Hex7 /8" PF Telefon: Telefax:

20 META SPECIA TYPES Below items are custom-built subject to special application place and existed equipment facilities. Their unique characters as follow: Customized mounting thread specification are acceptable. Single or multiple contact form (point) are workable. Any size measuring range. Switch activation N.O. or N.C. are available. FDSD9 FDSE9 Silicon cable M FDSF9 Silicon cable M Silicon cable M 3/8" PF 8 2"PT 2"PF 2 2 M4x0.7 f2.7 FD403D f2.7 f2 M4x0.7 FD003G FD703G PVC Cable PVC Cable 2"PF 2"PT 3"PT 2 3 f4 f2.7 M4x0.7 PVC Cable 3 f4 f2.7 f f2.7 f2 Telefon: Telefax: f7.2

21 ORDER INFORMATION FOR META SPECIA TYPE FD S A 6 2 D A 0 Type FDSA Float : RF-SA FDSB Float : RF-SB FDSC Float : RF-SC FDSD Float : RF-SD FDSE Float : RF-SE FDSF Float : RF-SF f28x28, f28x28, f28x28, f2x2, f4x, f2x2, Screw : /8"PF Screw : /8"NPT Screw : M2 Screw : 2"PT Screw : -/2"PF Screw : 3/8"PF Material of Wetted parts 0 : SUS304 6 : SUS36 Mounting : Top or Bottom Mounting 2 : Side Mounting Float Number ~4 floats Switching Capacity Max. D: 0W 240Vac /200Vdc, SPST G: 60W 220Vac, SPDT (only use for tube ]f2.7) K: 20W 0Vac /200Vdc, SPDT Contact Form A: Normal Open (N.O.) SPST B: Normal Close (N.C.) SPST C: AB SPDT F : float 2 points H: -N.O.,-N.C.(2 floats) ead wire ength (Unit=00) 03: 300 (SA, SB, SC, Standard length) 0: 00 (below 00) 0: 000 (SD, SE, SF, Standard length) : 00 (00~00) 00 per Unit Material of ead wire C: PVC cable (80C) F : SIICON cable (200C) P : PVC (80C) T : TEFON (200C) X : XPE (2C) AWG22 X 2C X f4 AWG24 X 2C X f4 AWG22 AWG24 For SA, SB, SC Type AWG22 (Standard) Telefon: Telefax:

22 TYPICA WIRING DIAGRAMS Supply water AUTO SUPPY CASE: SINGE FOAT DUA SWITCHES N.O. N.O.! N.C.! HI EVE N.C. OW EVE R N.O.! N.C.! R R2 Relay Relay 2 N.O. N.C. N.O.! N.C.! AUTO DRAIN CASE: SINGE FOAT DUA SWITCHES Drain water Supply water AUTO SUPPY CASE: DUA FOATS DUA SWITCHES N.O.! N.C.! N.O.! N.C.! OW EVE AUTO DRAIN CASE: DUA FOATS DUA SWITCHES Drain water N.O.! N.C.! R R2 Relay Relay 2 N.C. R OW EVE Solenoid valve R N.C. R Solenoid valve HI EVE N.O. R OW EVE N.O. R R Relay Telefon: Telefax: R2 R2 R Relay N.O.! N.C.! Solenoid valve HI EVE HI EVE N.O.! N.C.! R2 R2 Solenoid valve

RSF10 high level switch for boiling water

RSF10 high level switch for boiling water RSF10 high level switch for boiling water The RSF10 series drop float has been designed to eliminate problems associated with limescale build up around the pivot point of a conventional float switch. It

More information

Plastic tube flowmeters Series PT/PS

Plastic tube flowmeters Series PT/PS Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

INDUSTRIAL CONTROL INSTRUMENTS FOR PROCESS AUTOMATION TOR REED SWITCH

INDUSTRIAL CONTROL INSTRUMENTS FOR PROCESS AUTOMATION TOR REED SWITCH INSTRUCTION MANUAL _ LEVEL SWITCH TOR REED SWITCH Type A B PC PP PF Magnetic level switch. Top mount directly in the tank. Up to 6 action thresholds. DESCRIPTION Level switch formed by: Housing (1) with

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature

More information

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES 2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:

More information

Solenoid valves 2/2-way direct-operated Type EV210A

Solenoid valves 2/2-way direct-operated Type EV210A Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral

More information

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

Flow switches Series AD/VH

Flow switches Series AD/VH Flow switches Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight,

More information

Liquid Level Limit Switch liquiphant T FTL 20

Liquid Level Limit Switch liquiphant T FTL 20 Technical Information TI 64F/4/ae Liquid Level Limit Switch liquiphant T FTL 0 Level limit switch for liquids Applications The Liquiphant T FTL 0 is a level limit switch for virtually any kind of fluid

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

RC NETWORKS SALES GUIDE

RC NETWORKS SALES GUIDE SALES GUIDE INTRODUCTION TO Recent developments in electronic equipment have shown the following trends: Increasing demands for numerical control machines, robotics and technically advanced appliances

More information

ODOT ITB 063-14 Section 4: Flashers, Timers, & Software Systems Item 4-1

ODOT ITB 063-14 Section 4: Flashers, Timers, & Software Systems Item 4-1 ODOT ITB 063-14 Item 4-1 DATA SHEET SSF-86-3 ODOT ITB 063-14 Item 4-1 Solid State Flasher: Description: The PDC model SSF-86 solid state flasher is a dual circuit flasher designed for the Traffic Control

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Rubber Seal Series VF3000 Compact and lightweight: 26.4 mm

More information

mpm DIN 43650 CONNECTORS

mpm DIN 43650 CONNECTORS mpm DIN 43650 CONNECTORS : Highest quality, robust connectors for hydraulic and pneumatic electromechanical devices Broad offering of DIN 43650 connectors and devices Combined Brad and mpm cordsets : Provide

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY PRODUCT SPECIFICATION SHEET switched off. This results in energy savings during mild weather. Normal control will resume when T3 fails to

More information

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules CHIEF EN TERPRISES INC. M a s t e r I n t e r n a t i o n a l D i s t r i b u t o r Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules M AS TER IN

More information

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Introduction. Refrigerant Leak Detecting System. Feature and Benefits PSC European Refrigeration Controls Catalogue Catalog Section 9 Product Bulletin PD-GAS-E Refrigerant Leak Detecting System Introduction This range of refrigerant leak detecting systems is designed for

More information

ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.

ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc. ISO-9001:2000 certified EE300 Series Electromechanical Inventory Level Measuring System Aplus Finetek Sensor, Inc. PRODUCT INTRODUCTION OPERATING PRINCIPLE The EE300 series level measuring system is a

More information

Proximity Switches RS (Reed Switch)

Proximity Switches RS (Reed Switch) Proximity Switches RS (Reed Switch) General Pneumatic systems can often be combined with electric control circuits. The position of the piston in the cylinder can then be sensed by means of a proximity

More information

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge

More information

ELECTROMAGNETIC FLOWMETER COMPACT

ELECTROMAGNETIC FLOWMETER COMPACT R ELECTROMAGNETIC FLOWMETER COMPACT For conductivit Liquids MIK frequency-, switching-, analog otput digital plug on display Range from liquids, acids and caustic solutions:0.01-0.5...35-7000l/min Accuracy:

More information

! WARNING. Before using product, read and understand instructions.

! WARNING. Before using product, read and understand instructions. McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes

More information

Capacitive Prox E2K-X

Capacitive Prox E2K-X Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows

More information

Worcester DS/DM Series UltraSwitch Switch box

Worcester DS/DM Series UltraSwitch Switch box Worcester DS/DM Series UltraSwitch Switch box Features DS/DM Series Ultraswitch Description The DS/DM Series UltraSwich from Flowserve Worcester provides cost efficient, accurate and reliable position

More information

Electro-Pneumatic Bus Door Control Mechanism

Electro-Pneumatic Bus Door Control Mechanism Electro-Pneumatic Bus Door Control Mechanism Application and Feature 1. Pneumatic Door Mechanism actuates the open/close movements of bus door through two double acting cylinders and two linkages with

More information

Allen-Bradley 1397 400-600HP AC Line Filter Kit

Allen-Bradley 1397 400-600HP AC Line Filter Kit Installation Instructions IN Allen-Bradley 1397 400-600HP AC Line Filter Kit Cat. Nos. 1397-LF600 What This Option Provides What This Kit Contains This option is intended to be applied when the primary

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.

More information

STC 3S012-020-A Series Solenoid Valves

STC 3S012-020-A Series Solenoid Valves STC 3S012-020-A Series Solenoid Valves 3S012-020-A Series Solenoid Valve Specifications Valve Model 3S012-1/8-A 3S012-1/4-A 3S020-1/8-A 3S020-1/4-A Port Size (NPT) 1/8 1/4 1/8 1/4 Valve Type Action 3 Way,

More information

AUTODIALLER / QUICKDIALLER - SA132

AUTODIALLER / QUICKDIALLER - SA132 AUTODIALLER / QUICKDIALLER - SA132 INSTRUCTION LEAFLET ENGLISH www.thermomax-group.com CONTENTS 1 SETUP AT A GLANCE... 2 2 FOREWORD....... 3 3 INSTALLATION...... 4 4 KEYPAD AND INDICATORS...... 5 SETTING

More information

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm) Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers

More information

DLP-PU/E Instruction Manual

DLP-PU/E Instruction Manual Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

NEW! Typical Applications. Motor controls Thermostatics Portable tools Air Conditioner. Materials

NEW! Typical Applications. Motor controls Thermostatics Portable tools Air Conditioner. Materials TF2 Series Miniature Snapacting Switches NEW! Features/Benefits Broad range of operating forces Ratings up to 10 AMPS Wide variety of actuator styles Quick connect terminations Typical Applications Motor

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

Magnetic Proximity Switches Series CST - CSV and CSH

Magnetic Proximity Switches Series CST - CSV and CSH Magnetic Series CST - CSV and CSH Reed, Electronic»» Designed to fit into the cylinder profile barrel»» 3 models (CST - CSV - CSH) are suitable for all Camozzi s cylinder range»» With or without M8 connector

More information

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS INTRODUCTION Rupture discs are often used as primary pressure relief devices and to isolate pressure relief valves. When used as a primary pressure relief

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications

More information

WHOLESALE DIRECT INC. 5620 WEST 65TH STREET

WHOLESALE DIRECT INC. 5620 WEST 65TH STREET Auto Pump V 200 100 0 100 Max Rating Vehicle mount compressor ensures truck air brake system is properly pressurized for immediate dispatch from station Pressure switch regulated operation automatically

More information

OPL BASIC. Dosing System for Professional Laundry machines. Contents

OPL BASIC. Dosing System for Professional Laundry machines. Contents OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page

More information

Relative and absolute pressure switch type 529

Relative and absolute pressure switch type 529 Relative and absolute pressure switch type 529 Pressure range -1... 0 60 bar The compact type 529 pressure switch is based upon the Huba Control developed unique ceramic technology used for the last 20

More information

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2 R Extended Range Inductive Prox Greater Sensing Distance Offers Greater Design Flexibility H Sensing distances approximately 1.5 to 2 times larger than that of any conventional Sensor H Reduces problems

More information

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features Booster Pump Control Valve Quick Active Check Valve Isolates system from the effects of pump starts and stops for: Solitary single speed pumps Battery of single speed pumps (add & switch) Battery of variable

More information

Failure code manual. content

Failure code manual. content Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一

More information

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component. Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on

More information

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS Photoelectric These sensors use light sensitive elements to detect objects and are made up of an emitter (light source) and a receiver. Four types of photoelectric

More information

Solenoid Operated Directional Valves

Solenoid Operated Directional Valves INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS SERIES 35 Solenoid Operated Directional Valves SF-2C-115A-35 S-1AY-12D-35 SD-2C-12D-35 Features High Flow/ High Pressure: Up to 40 gpm / 5000 psi working pressure*.

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power) MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)

More information

T5000 T000 LCD Digital Fan Coil Thermostat

T5000 T000 LCD Digital Fan Coil Thermostat T5000 T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostats are designed to control heating, cooling, or year round air conditioning unit in Commercial,

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and

More information

TF2 Series Miniature Snap-acting Switches

TF2 Series Miniature Snap-acting Switches Miniature Snapacting Switches Features/Benefits Broad range of operating forces Ratings up to 10 AMPS Wide variety of actuator styles Quick connect terminations Typical Applications Motor controls Thermostatics

More information

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables. Quick-Connect Cables with Connectors PA Simplifies sensor wiring. Wide variety of connectors attached to cables. Series No wiring or staking work needed Shorter replacement time in unlikely event of sensor

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology Plastic Flow Meters for gases & liquids, using TROGAMID* & POYSUFONE Technology Applications Monitoring & Control of processes for: Water & Waste Water Treatment Chemical, Petrochemical & Paper Pharmaceutical,

More information

TS93 EMR T/PT/TDE. Surface applied door closer

TS93 EMR T/PT/TDE. Surface applied door closer TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double

More information

SMART SENSOR COLLECTION

SMART SENSOR COLLECTION TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

Technical Guide. Thermostats Air Conditioning

Technical Guide. Thermostats Air Conditioning Technical Guide Thermostats Air Conditioning TECICA GUIDE TERMOSTATS AIR CODITIOIG Thank you for choosing our products ote: Technical information contained in this catalog may be changed or updated by

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

Inductive Proximity Sensors

Inductive Proximity Sensors M12 Inductive Proximity Sensors Standard Length Mini's Extended Sensing 3 Wire DC 2 Wire DC 2 Wire AC (Wiring Schematic) 3 Wire DC PNP Normally Open (1) IMM32122C IMM35124C IMN32122C IMN35124C IMN32122M12

More information

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting Female NPT Thread 3/8 OD Tube 3/8 Push-In Fitting 2P050 Series Solenoid Valve Specifications Valve Model 2P050-1/4 2P050-3/8

More information

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2 Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened

More information

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED)

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED) NX SERIES Compact Multi-voltage Photoelectric Power Supply Built-in Multi-voltage photoelectric sensor usable worldwide Conforming to ow Voltage and EMC Directive Multi-voltage The NX series can operate

More information

Electromagnetic pump designation GOTEC

Electromagnetic pump designation GOTEC Electromagnetic pump designation GOTEC E T S 21 - E : In beginning of the designation for all pumps based on the Electromagnetic principle. 1 T : means the complete square motor (coil + metallic frame

More information

DS 1.102 DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

DS 1.102 DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches DS 1.102 02/99 AIR ROOM TEMPERATURE SENSOR with fan speed control switches Specification No. 528-X-XXX* The Active Room Temperature sensor incorporating fan speed control switches is designed to give a

More information

Thermometer in stainless steel with capillary and switch contacts

Thermometer in stainless steel with capillary and switch contacts Design Type Case diameter Thermometer in and switch contacts 7308 = back flange for wall mounting 7312 = front flange for panel mounting 7310 = mounting bracket for wall mounting Dim 100 mm or 160 mm Accuracy

More information

Induced voltages and Inductance Faraday s Law

Induced voltages and Inductance Faraday s Law Induced voltages and Inductance Faraday s Law concept #1, 4, 5, 8, 13 Problem # 1, 3, 4, 5, 6, 9, 10, 13, 15, 24, 23, 25, 31, 32a, 34, 37, 41, 43, 51, 61 Last chapter we saw that a current produces a magnetic

More information

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) DESCRIPTION The Radar Level Meters of BM COMPACT WAVE 6.3 GHz series are excellent devices for no contact level measurement. The microwave impulses, emitted

More information

2.12. page 223 2.12. Products for Explosion hazardous Environment

2.12. page 223 2.12. Products for Explosion hazardous Environment 2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available

More information

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR (For NEW 2007 ALL WHITE KWIK-KITS ONLY) Warning do not attempt to install A/C units unless you are experienced with servicing

More information

Conductive Level Switch FK 2 Technical Data:

Conductive Level Switch FK 2 Technical Data: Level switch for conductive liquids Optional electrode length adjustment Hygienic installation in accordance with EHEDG Wetted parts compatible with FDA requirements Potted electronic Not influenced by

More information

Shunt lock function 3066

Shunt lock function 3066 Version: January 2004 Contents Alarm System Activation unit Deactivation unit Digital locking cylinder or Smart Relay 1.0 Method of Operation 4 1.1 General 4 1.2 Turning the Alarm System On 4 1.3 Turning

More information

Industrial Ringdown/Autodialer Telephone SCR Series

Industrial Ringdown/Autodialer Telephone SCR Series Industrial Communications Worldwide Industrial Ringdown/Autodialer Telephone Installation & Operation SCR 11 SCR 41 P005603 Rev. A 060612 5/28/2007 3:58 PM 7552-10th Street N.E. Calgary, Alberta, Canada

More information

Data Sheet. Electro-mechanical counters Hengstler 800 series

Data Sheet. Electro-mechanical counters Hengstler 800 series Data Pack D Issued March 00 504897 Data Sheet Electro-mechanical counters Hengstler 800 series The 800 series totalising and predetermining batch counters, manufactured by Hengstler, is available from

More information

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions. B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary

More information

ARI-DP30 / DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP Pneumatic actuator ARI-DP

ARI-DP30 / DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP Pneumatic actuator ARI-DP ARI-DP30 / DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP Pneumatic actuator ARI-DP ARI-DP30 Pneumatic actuator Page 2 ARI-DP32 ARI-DP33 Pneumatic actuator DP-Actuator Extended stem

More information

12V Dimmable Driver EL-TMDRVR

12V Dimmable Driver EL-TMDRVR Elemental LED, LLC website: elementalled.com 11 9 5 P a r k A v e., S u i t e 2 11 Emeryville, CA 94608 toll free 877.564.5051 fax 510.740.4457 12V Dimmable Driver EL-TMDRVR ETL Listed #4001928 CSA Listed

More information

Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S

Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S *1756202470* 17562.0247.0 REV3 06/09 2012 Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S Issue Table description Issue n. of pages Overall view 06/2009 1 C.h.

More information

Pneumatic Grippers Parallel and Angular Grippers. Catalog 1900-2/US

Pneumatic Grippers Parallel and Angular Grippers. Catalog 1900-2/US Pneumatic Grippers Parallel and Angular Grippers Catalog 19-2/US Catalog 19-2/US OContents GPR Series Rotary vane driven design GPR GPCR Series P5G-HPM(C) Series P5G-HP Series GPT Series P5G-AP Series

More information

2 position single. (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC. 2 position double

2 position single. (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC. 2 position double 4/ Port Solenoid Valve Rubber Seal VZ1000/000/000 Solenoid Valve Variations Port Size Effective area (mm 2 ) Position solenoid Voltage Electrical entry Option/ Indicator light and surge voltage suppressor

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

Bolted contact switches. Pringle switches

Bolted contact switches. Pringle switches Bolted contact switches Pringle switches Eaton s Pringle bolted contact switches History Eaton s PringleT switches have helped pioneer the development of high-quality electrical products for commercial

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

Solenoid Operated Directional Valves

Solenoid Operated Directional Valves INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS SERIES 35 Solenoid Operated Directional Valves SD-2B-115A-35 SDS-2H-12D-35 S-2B-115A-35 Features High Flow/ High Pressure: Up to 25 gpm / 5000 psi working

More information

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary

More information

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST 12VDC MAGNETIC ED DIMMABE POER SUPPIES SPEC SEET DIGEST TM-30-DIM TM-50-DIM T-60-DIM TM100-DIM TM200-DIM TM300-DIM iring Diagram for TM-50-DIM and TM-100-DIM ED 12VDC MAGNETIC DIMMABE 30 POER SUPPY Smallest

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

OLI. Oil level indicator

OLI. Oil level indicator OLI Oil level indicator Oil level indicator Unexpected or accidental oil leakages may occur randomly along transformer s lifetime. Clear indication of oil level inside transformer tank and on load tap

More information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................

More information

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011 Instruction Manual 2in1 LAN Tester & Multimeter Model: LA-1011 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.