DALI Power Module (LQSE-2DAL-D) DALI Bus 1. DALI Bus 2. HomeWorks. Wallstation. Power. Eye QS Control Power Up to 100. Module.

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "DALI Power Module (LQSE-2DAL-D) DALI Bus 1. DALI Bus 2. HomeWorks. Wallstation. Power. Eye QS Control Power Up to 100. Module."

Transcription

1 DAI Module E-2DA-D DAI Fixture Controller DAI Module a The DAI Module is a DI-rail mounted controller for DAI -compliant Digital Addressable loads. It provides DAI bus power and control for two independent DAI buses with up to 64 ballasts each. Features Provides power for two buses of DAI compliant digital addressable loads (up to 250 ma per bus). Each DAI Bus can control a maximum of 16 zones. failure memory retains programming in the event of a power loss. DAI Module can be used in a HomeWorks system to control and manage light in an entire home or building. DAI Module E-2DA-D (0) mm DAI Module (E-2DA-D) DAI Bus 1 DAI Bus 2 to 64 ballasts on each link DAI Module HomeWorks Wallstation HomeWorks GRAFIK 230 V~ Module Processor Eye Control to 100 ink Sivoia Shade / Drapery Contact Closure Interface total devices Supply DAI is registered trademark of ZVEI-Zentralverband Elektrotechnik Job ame: Model umbers: Job umber:

2 DAI Module E-2DA-D DAI Fixture Controller Specifications ightning strike protection meets ASI/IEEE standard Can withstand voltage surges of up to V~ and current surges of up to A. Stand by power: 7 W BTUs / hour when fully loaded: 24 DAI Bus Output: 16 V- 250 ma maximum per bus. Standards IEC utron Quality Systems registered to ISO CE C-Tick S Environment Ambient Temperature Operating Range: 0 ºC to 40 ºC. Relative Humidity: less than 90% non-condensing. Calibration point maximum: 75 ºC For indoor use only. Terminals Mains Wiring: 1,0 mm 2 to 4,0 mm 2 (18 AWG to 12 AWG) DAI Bus Wiring: 1,0 mm 2 to 4,0 mm 2 (18 AWG to 12 AWG) ink Wiring: 1,0 mm 2 (18 AWG) Mounting Intended to mount within an IP20 (minimum) rated consumer panel or breaker panel with integrated DI rail and dead cover Width = 9 DI modules (161,7 mm). Programming and Compatibility Requirements The E-2DA-D can only be used with the HomeWorks system. Setup and programming of the DAI Module is done through the HomeWorks programming software. HomeWorks software version 3.1 or higher required a DAI Buses to 64 DAI compliant loads on each bus can be addressed and grouped into 16 zones. DAI Module supplies 250 ma to power each bus. DAI Bus wires are polarity insensitive and topology-free. ink imits A link in a HomeWorks system can have up to 512 zones (outputs) and 100 devices. A ballast or driver counts as 1 zone unless specifically grouped into zones from the HomeWorks software. Each DAI Module counts as one device toward the 100 device limit. A maximum of 8 fully loaded DAI Buses may be connected to a single link. HomeWorksR Wallstations HomeWorks wallstations can be configured to control DAI Modules with the HomeWorks programming utility. ED indicator displays the status of programmed lights. Troubleshooting and Maintenance Features Maintains redundant memory of ballast programming for ease of single or multiple ballast replacement. To verify DAI lights connected to DAI bus 1 and bus 2: Enter Mode: Press and hold button on the DAI Module until the ED starts flashing. : Each press of either the DAI 1 or DAI 2 button will cycle the lights between high-end, low-end and flash for that bus. Exit Mode: Press and hold button until ED stops flashing. DAI is registered trademark of ZVEI-Zentralverband Elektrotechnik Job ame: Model umbers: Job umber:

3 DAI Module E-2DA-D DAI Fixture Controller Overview of Wiring Terminals and Mechanical Dimensions a IEC PEV / EC Class 2 ink DAI Bus 1* Rev. B DAI Bus 2* 1771 DAI Module E-2DA-D (0) ,7 mm 8 mm Mains Wiring 161,7 mm * Wire according to local codes. 60,6 mm DAI is registered trademark of ZVEI-Zentralverband Elektrotechnik EC is a registered trademark of the ational Fire Protection Association, Quincy, Massachusetts Job ame: Model umbers: Job umber:

4 8 mm DAI Module E-2DA-D DAI Fixture Controller Wiring: Mains Voltage DAI Module E-2DA-D (0) DAI Module E-2DA-D (0) mm Wiring from Distribution to Module a M E V~ Turn off all circuit breakers or isolators feeding the Module unit at the distribution panel. Run line, neutral, and earth/ground wires from a 8 mm 230 V~ 50/60 Hz feed to the DAI Module. Emergency ighting Applications Use normal (non-essential) power only to power the DAI Module. When normal power drops out, the DAI Module will not power the DAI Buses. When this occurs, ballasts powered from emergency feeds go to their emergency mode, full light output by default. Mains Wiring and IEC PEV / EC Class 2 Separation The DAI Module is designed to separate mains wiring from IEC PEV / EC Class 2 circuits. Follow appropriate local and national codes to avoid violating required separation guidelines. Distribution Panel Earth/Ground eutral Mains/ive DAI is registered trademark of ZVEI-Zentralverband Elektrotechnik EC is a registered trademark of the ational Fire Protection Association, Quincy, Massachusetts Job ame: Model umbers: Job umber:

5 8 mm DAI Module E-2DA-D DAI Fixture Controller Wiring: DAI Bus a DAI Bus 1 DAI 1 DAI 1 DAI Module E-2DA-D (0) DAI Bus 2 DAI 2 DAI 2 The DAI Module will supply power for two independent DAI Bus, which supports a maximum of 64 ballasts per bus. DAI Wiring DAI wiring is not IEC PEV/EC Class 2. DAI wiring is treated as mains voltage, and thus may be run within the same sheathing. Ensure that there is no greater than a 2 V~ drop between the DAI Module and the end of the DAI Bus. Consult all national and local electrical codes for separation requirements. Maximum DAI -compliant Wire Gauge Bus Wire ength 4,0 mm 2 (12 AWG) 671 m 2,5 mm 2 (14 AWG) 427 m 1,5 mm 2 (16 AWG) 275 m 1,0 mm 2 (18 AWG) 175 m DAI is registered trademark of ZVEI-Zentralverband Elektrotechnik EC is a registered trademark of the ational Fire Protection Association, Quincy, Massachusetts Job ame: Model umbers: Job umber:

6 8 mm DAI Module E-2DA-D DAI Fixture Controller Wiring: ink a IEC PEV / EC Class 2 ink Wiring ink communicates using IEC PEV / EC Class 2 wiring. DAI Module E-2DA-D (0) Follow all applicable national and local codes for proper circuit separation and protection. Wiring may be daisy chained or t-tapped. Total length of link must not exceed 600 m. Do OT connect terminal 2. Wire Gauge (terminals 1 and 2): 1 pair 1,0 mm( (18 AWG) Data (terminals 3 and 4): 1 pair 0,5 mm( to 1,0 mm( (20 AWG to 18 AWG) twisted and shielded Can use utron cable GRX-CB-346S-500 (1) (2) o Connection (3) (4) ower Module DA-D 50/60 Hz 80 ma com +44.(0) DAI is registered trademark of ZVEI-Zentralverband Elektrotechnik EC is a registered trademark of the ational Fire Protection Association, Quincy, Massachusetts Job ame: Model umbers: Job umber:

HomeWorks QS Processor

HomeWorks QS Processor product specifications 369-376 The processor provides control and communication to system components. The Ethernet links allow communication to the software, integration with third party systems and communication

More information

QSE-CI-NWK-E Control Interface

QSE-CI-NWK-E Control Interface QSE-CI-NWK-E Control Interface 369373e 1 04.05.16 The QSE-CI-NWK-E is a versatile integration access point for Lutron QS-based systems. Through either RS232 or TCP / IP over Ethernet, third-party devices

More information

LP Dimming Panels. GRAFIK Systems. Power Equipment. LP Dimming Panels

LP Dimming Panels. GRAFIK Systems. Power Equipment. LP Dimming Panels 369344c 04.28.204 LP dimming panels are ideal for projects with many small loads. Each panel provides power and dimming for up to 32 dimming legs. Features Works directly with incandescent, magnetic low

More information

Hi-lume A-Series LED Overview

Hi-lume A-Series LED Overview Hi-lume Overview 369-3 Rev. C 1 12.17. Hi-lume is a high-performance driver that provides smooth, continuous 1% dimming for virtually any fixture, whether it requires constant current or constant voltage.

More information

System Example. Energi Savr NodeT QSE-CI-AP-D Programming Interface

System Example. Energi Savr NodeT QSE-CI-AP-D Programming Interface NodeT NodeT The is a programming interface designed to be used with NodeT units. It is compatible with the entire NodeT product family (models starting with QSN- and QSNE-), and works with an intuitive

More information

Switching Power Module

Switching Power Module 369357e 1 06.22.16 Description Provides capability for a zone on a GRAFIK Eye control unit (or other product) to switch a fully loaded circuit of lighting. May be used to switch incandescent, electronic

More information

EcoSystemTM Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystemTM C5-BMJ-16A. EcoSystemTM Dimming Module

EcoSystemTM Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystemTM C5-BMJ-16A. EcoSystemTM Dimming Module Dimming Module Dimming Power Module for 3-wire Lutron Dimming Ballasts 16A Module-1 09.27.07 Power Indicator (PW) Indicateur de puissance (PW) Indicador de Alimentación (PW) Status Indicator () Indicateur

More information

Control Interfaces. GRAFIKR Systems. 369-564a 1 10.25.11 LUT-DMX

Control Interfaces. GRAFIKR Systems. 369-564a 1 10.25.11 LUT-DMX 369-564a 1 10.25.11 DMX 512 Control Interface Description Allows GRAFIK EyeR lighting controls to operate lighting and other equipment that uses the DMX 512 protocol, including: - Strobes, fiber optic

More information

QSE-CI-DMX Control Interface

QSE-CI-DMX Control Interface Control Interface 369372c 1 04.05.16 Description The operates either in a standalone QS system or a Quantum system. It performs different functions depending on the system in which it is operating. QS

More information

GRX-PWM Pulse Width Modulation Interface

GRX-PWM Pulse Width Modulation Interface Pulse Width Modulation Interface pwm1 05.30.06 COOPERSBURG, PA 18036 U.S.A. Coopersburg, G 8 BR PA 18036 U.S.A. 144317 GRXTVI 19 P10 CB 0791275 Ratings Load T ype Switched Lowvoltage Load Type Switched

More information

Phase-Adaptive Power Module

Phase-Adaptive Power Module 369356c 1 06.22.16 Description Provides capability for a zone on a GRAFIK Eye control unit (or other product) to dim a fully loaded circuit of lighting. May be used to control incandescent, electronic

More information

QSE-IO Control Interface

QSE-IO Control Interface QSE-IO Control Interface 369374d 1 04.05.2016 The QSE-IO contact closure interface provides integration with third-party equipment requiring contact closure input / output, including occupancy and vacancy

More information

EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystemR Dimming Module

EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystemR Dimming Module EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts The Lutron EcoSystem dimming power module allows integration of Lutron 3-wire phase controlled dimming ballasts into Lutron EcoSystem bus

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

PXL-250: Network Wiring

PXL-250: Network Wiring This document provides the network wiring requirements for a PXL-250 access control network. Network Requirements The PXL-250 uses a half-duplex, RS-485 communication bus. Per the RS-485 specification,

More information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual 5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...

More information

Watt-hour Meter Interface Module

Watt-hour Meter Interface Module Watt-hour Meter Interface Module MIM-B16* PIM (Pulse Input Module) Watt-hour Meter Interface Module can be exclusively used for DMS 2 power distribution, displaying power consumption for each watt-hour

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

OMX-RS232 Control Interface

OMX-RS232 Control Interface GAFIK Systems Control Interface omx-rs- 09..0 Description Integrates GAFIK 000/6000/7000 Systems with a touchscreen or other digital equipment that supports S communication. Provides S monitoring commands

More information

S-series Mass Connection Solutions

S-series Mass Connection Solutions DeltaV Distributed Control System Product Data Sheet March 2015 S-series Mass Connection Solutions Fast, easy and error-free cabinet wiring Modular design, improves reliability Lowers overall termination

More information

USB-SSR08 Specifications

USB-SSR08 Specifications USB-SSR08 Specifications Document Revision 1.2, February, 2010 Copyright 2010, Measurement Computing Corporation Typical for 25 C unless otherwise specified. Specifications in italic text are guaranteed

More information

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer

More information

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET: SWITCH The Budderfly lighting switch is a Decora style, plug-and-play replacement for your existing building switches. Installing a Budderfly adapter transforms your building s existing wiring into the

More information

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1. USER GUIDE Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator Version 1.3 DM Engineering 2174 Chandler St. Camarillo, CA 91345-4611 805-987-7881 800-249-0487

More information

Technical Description

Technical Description abcxyz Contents 1. General...1 2. Block Diagram...2 3. First Steps...2 4. Technical Data...3 4.1 AS-Interface...3 4.2 Pin Out...4 4.3 Supply of Periphery...4 4.4 Inputs...5 4.5 Outputs...5 4.6 Mechanical

More information

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.

More information

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown Self-Regulating 920 Series Dual-point heat-tracing control system Power-Limiting Mineral Insulated 920*E4FWL*SIS302*SS3102 shown Product overview The DigiTrace 920 is a compact, full-featured, microprocessor-based,

More information

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm Characteristics XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm Complementary Detection system Kit composition [EAA] effective aperture angle Emission Main Range of product Product or

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

4000 Series Installer s Guide

4000 Series Installer s Guide LUTON PLEASE EAD 000 Series Installer s Guide Control Unit Models 00 and 500 Section : Introduction GAFIK Eye 000 Series Control Unit......................................... System unications and Capacities.......................................

More information

USB-ERB08 Specifications

USB-ERB08 Specifications USB-ERB08 Specifications Document Revision 1.4, April, 2016 Copyright 2016, Measurement Computing Corporation All specifications are subject to change without notice. Typical for 25 C unless otherwise

More information

Application/Connection Examples

Application/Connection Examples This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.

More information

MACTek Corporation. USB HART Interface. Users Manual

MACTek Corporation. USB HART Interface. Users Manual MACTek Corporation USB HART Interface DM01003100AA February, 2003 LIMITED WARRANTY VIATOR Interface for HART MACTek Corporation warrants this Interface and all of its component against defects in materials

More information

User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters

User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm

More information

RM17UAS. Main. Product or component type. Product specific application. Relay monitored parameters

RM17UAS. Main. Product or component type. Product specific application. Relay monitored parameters Characteristics voltage control relay RM17-U - range 65..260 V AC Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main Range of

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

Lightning Arresters P30027 18 KVA P30038 10 KVA. Description & Installation

Lightning Arresters P30027 18 KVA P30038 10 KVA. Description & Installation Lightning Arresters P30027 18 KVA P30038 10 KVA Description & Installation Printed in USA 09/11 TO330 Rev. B Table of Contents Page 1.0 SCOPE 2 2.0 PRODUCT OVERVIEW 2 2.1 Intended Uses 2 2.2 Lightning

More information

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5 T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

HomeWorks QS Wired seetouch Designer Keypads

HomeWorks QS Wired seetouch Designer Keypads HomeWorks QS seetouch keypads provide homeowners with a simple and elegant way to operate lights, shades / draperies, motorized screens, thermostats, and many other devices. HomeWorks QS seetouch keypads

More information

IntesisBox Modbus Server SAMSUNG Air Conditioners

IntesisBox Modbus Server SAMSUNG Air Conditioners IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled M BASIC 1 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver for manual testing SEV for output voltage < 60 V DC ow-profile casing (21 x 30 mm cross-section) 5-year

More information

Multi-Range Programmable DC Power Supplies 9115 Series

Multi-Range Programmable DC Power Supplies 9115 Series Data Sheet 1200 W Multi-Range DC Power Supplies Features & Benefits Any 9115 series model can replace several supplies on your bench or in your rack. Unlike conventional supplies with fixed output ratings,

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: WWW.BRITEQ-LIGHTING.COM TABLE OF CONTENTS

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: WWW.BRITEQ-LIGHTING.COM TABLE OF CONTENTS STGE COO 48 Preliminary User Guide Official version will follow soon on: WWW.BITEQ-IGHTIG.COM TBE OF COTETS 1. Safety Instruction 2. Technical Specification 3. How To Set The Unit 4. How To Control The

More information

FL SWITCH SF... Factory Line Switches With Standard Functions. Data Sheet

FL SWITCH SF... Factory Line Switches With Standard Functions. Data Sheet Factory Line Switches With Standard Functions Data Sheet 05/2004 This data sheet is valid for the following products: FL SWITCH SF 8TX FL SWITCH SF 7TX/FX FL SWITCH SF 6TX/2FX FL SWITCH SF 16TX FL SWITCH

More information

NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet

NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet The NX-591NE-GSM is a microprocessor-controlled GSM interface module used to connect the NetworX series of control panels to GSM cellular networks

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue

More information

LIEBERT VNSA Installation Sheet

LIEBERT VNSA Installation Sheet LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display

More information

Solar monitoring gateway quick start guide

Solar monitoring gateway quick start guide Instructional Leaflet I70002E LGATE101-1B LGATE101-1A LGATE101-5B LGATE101-5A Contents Description Page General................................. 2 Information collection sheet............... 2 Quick reference

More information

ZONE SELECTIVE INTERLOCKING (ZSI) APPLICATION AND TESTING GUIDE SIEMENS WL UL489 AND UL1066 AIR CIRCUIT BREAKERS

ZONE SELECTIVE INTERLOCKING (ZSI) APPLICATION AND TESTING GUIDE SIEMENS WL UL489 AND UL1066 AIR CIRCUIT BREAKERS Definition: Zone Selective Interlocking (ZSI) - A method which allows two or more ground fault breakers to communicate with each other so that a short circuit or ground fault will be cleared by the breaker

More information

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX The Lantana Luminaire linear light fixture is designed to seamlessly integrate with compatible Lutron control systems. It can be easily

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information. Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an

More information

LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital

More information

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution

More information

TMS TANK MANAGEMENT SYSTEM

TMS TANK MANAGEMENT SYSTEM TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS

More information

IP65 IP67 SELV HLG-150H-12 HLG-150H-15 HLG-150H-20 HLG-150H-24 HLG-150H-30 HLG-150H-36 HLG-150H-42 HLG-150H-48 12V 15V 20V 24V 30V 36V 42V 48V

IP65 IP67 SELV HLG-150H-12 HLG-150H-15 HLG-150H-20 HLG-150H-24 HLG-150H-30 HLG-150H-36 HLG-150H-42 HLG-150H-48 12V 15V 20V 24V 30V 36V 42V 48V Features : Universal AC input / Full range (up to 305VAC) Built-in active PFC function High efficiency up to 94% Protections: Short circuit / Over current / Over voltage / Over temperature Cooling by free

More information

MechoNet TM Network Interface (MNI) Specification Submittal

MechoNet TM Network Interface (MNI) Specification Submittal MechoNet TM Network Interface (MNI) Specification Submittal Models MechoNet Network Interface: MNI RJ (RJ45 Motor Ports): Stock No.: IMNI 0001 TP AS (US version) Stock No.: IMNI 0004 TP AS (UK version)

More information

LOXONE 12 Channel Amplifier

LOXONE 12 Channel Amplifier LOXONE 12 Channel Amplifier Item no.: 200110 Thank you for purchasing the Loxone Twelve Channel Amplifier. The versatility of the Amplifier makes it the perfect choice for almost every type of custom multi-room

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

1 light dimming module

1 light dimming module 1 light dimming module Ref: MOD0400 STAT The MOD0400 is a lighting control module that allows to dimming and monitoring of 1 halogen or incandescent light sources of up to 250W. This lighting circuit can

More information

Lighting Control Systems

Lighting Control Systems Lighting Control Systems GAFIK 7000P Including... Installation and Maintenance Guide System Overview Use this guide to successfully install a GAFIK7000, GAFIK6000, or GAFIK5000 lighting control system.

More information

L5354 ControlNet Communications Interface

L5354 ControlNet Communications Interface L5354 ControlNet Communications Interface Technical Manual HA470733 Issue 2 Copyright SSD Drives Inc 2005 All rights strictly reserved. No part of this document may be stored in a retrieval system, or

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

IntesisBox KNX - LON

IntesisBox KNX - LON IntesisBox KNX - Gateway for integration of devices into KNX systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi Heavy Industries, Toshiba, Fujitsu,

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

T7560A,B,C Digital Wall Module

T7560A,B,C Digital Wall Module T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital

More information

Remote Power Panels with Breakers

Remote Power Panels with Breakers Remote Power Panels with Breakers 8 Series Panels & Enclosures N/A N/A Remote power panels with breakers are available in two different sizes, each of which may be either surfacemounted or recess-mounted,

More information

NI 9423. NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

NI 9423. NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module DATASHEET NI 9423 8-Channel Sinking Digital Input Module 8-channel, 100 µs digital input 24 V logic, sinking digital input Compatible with NI CompactDAQ counters 250 Vrms, CAT II isolation 10-position

More information

ADM1TE 5/30A DIN rail single phase two wire energy meter

ADM1TE 5/30A DIN rail single phase two wire energy meter ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

PCI/PXI ETHERNET ADAPTERS

PCI/PXI ETHERNET ADAPTERS INSTALLATION GUIDE PCI/PXI ETHERNET ADAPTERS Installing Your PCI Board National Instruments offers several Ethernet adapters based on the Intel 82559-compatible Ethernet controller. This document explains

More information

IP Link Device Interface Ethernet Communication Sheet

IP Link Device Interface Ethernet Communication Sheet This document provides additional assistance with wiring your Extron IP Link enabled product to your device. Different components may require a different wiring scheme than those listed below. For complete

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

Multi-Range Programmable DC Power Supplies 9115 Series

Multi-Range Programmable DC Power Supplies 9115 Series Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional

More information

TAC I/NETTM MR-AHU-HP. Application Specific Controller

TAC I/NETTM MR-AHU-HP. Application Specific Controller TAC I/NETTM MR-AHU-HP Both the MR-AHU and MR-HP controllers are application specific controllers (ASCs). The intention of the design is to reduce total install cost through pre-engineered control algorithms

More information

KNX Panasonic Air Conditioners

KNX Panasonic Air Conditioners IntesisBox KNX Panasonic Air Conditioners Gateway for Panasonic ECOi and PACi system integration into KNX networks Up to 30 Outdoor units Up to 64 Indoor units PA-AC-KNX-64/128 EIA485 U1U2 line U1U2 line

More information

R60 USB to CAN interface Manual (1.5 EN)

R60 USB to CAN interface Manual (1.5 EN) R60 USB to CAN interface Manual (1.5 EN) General information R60 USB to CAN interface Manual Version 1.5 EN, 02/2010, DOC01586 Copyright 2010 by ; all rights reserved. Eugen-Adolff-Strasse 134, D-71522

More information

Foxboro Evo Process Automation System

Foxboro Evo Process Automation System Foxboro Evo Process Automation System Product Specifications PSS 31H-2Z32 FBM232 Field Device System Integrator Module, 10/100 Mbps Ethernet, Single The FBM232 Field Device System Integrator (FDSI) module

More information

INSTALLATION MANUAL. Room thermostat EKRTR EKRTETS

INSTALLATION MANUAL. Room thermostat EKRTR EKRTETS INSTALLATION MANUAL EKRTR EKRTETS 1 2 1 2 3 60 87 170 161 ±1.5 m >0.2 m 3 5 4 34 125 4 5 28 50 EKRTR EKRTETS Contents Read this manual attentively before starting up the unit. Do not throw it away. Keep

More information

HomeWorks QS Wired Signature SeriesTM Keypads

HomeWorks QS Wired Signature SeriesTM Keypads HomeWorksR QS Wired Signature SeriesT keypads provide homeowners with a simple and elegant way to operate lights, shades/draperies, motorized screens, thermostats,and many other devices. HomeWorksR QS

More information

Three-phase monitoring relay CM-PVE

Three-phase monitoring relay CM-PVE Data sheet Three-phase monitoring relay CM-PE The three-phase monitoring relay CM-PE monitors the phase parameter phase failure as well as over- and undervoltage in three-phase mains. 2CDC 251 006 S0012

More information

Electronic timer CT-TGD.12

Electronic timer CT-TGD.12 2CDC 251 098 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection

More information

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Applied Electronics. Commercial Dimming System UPDATE NOTICE REV. A Applied Electronics Commercial Dimming System UPDATE NOTICE This notice is to inform the end user of an additional feature added to this DP12/2400 dimming unit. This unit has been outfitted with

More information

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage Description Supports DALI interface driver Programming Supports 0-10V Programmable Driver Programming Supports Other Controllers (TDD-ANPNx, SDD-AAPNx) Off-line programming capability Auto programming

More information

PD 100A. Printing data system

PD 100A. Printing data system PD 100A Printing data system Operating instructions ENGLISH IMPORTANT: Read these instructions carefully before installing and using the device; do not forget following all additional information. Keep

More information

SYSTEM DESCRIPTION Termination Boards

SYSTEM DESCRIPTION Termination Boards PROCESS AUTOMATION SYSTEM DESCRIPTION Termination Boards Non-IS Termination Boards for Yokogawa CENTUM C3 and ProSafe RS ISO9001 With regard to the supply of products, the current issue of the following

More information

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual Infrastructure Management & Monitoring For Business-Critical Continuity Liebert icom-do User Manual TABLE OF CONTENTS 1.0 INTRODUCTION............................... 1 2.0 INSTALLATION...............................

More information

2013 Wireless Video Intercom INSTALLATION GUIDE

2013 Wireless Video Intercom INSTALLATION GUIDE 2013 Wireless Video Intercom INSTALLATION GUIDE INDEX System configuration and wiring VL-SWD501 System Component.. 4 VL-SWD501EX wiring schematic diagram VL-SWD501EX wiring type and length... 5.... 6 Door

More information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................

More information

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W T5 TC-DEL TC-SEL TC-TEL TC-DD PC BASIC, 4 28 W Electronic ballast for system output < 25 W Product description CELMA Energy Efficiency Index A2 / A3 Nominal life time up to 50,000 h (at ta 50 C with a

More information

MAJORSINE Power Inverter

MAJORSINE Power Inverter MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions

More information

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB Product Manual ABB i-bus KNX IP Interface IPS/S 2.1 Intelligent Installation Systems ABB This manual describes the function of the IP Interface IPS/S 2.1 with the application program IP Interface. Subject

More information

Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596

Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596 Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596 Product overview The Tracer ZN517 controller is a field-installed, application-specific controller that provides directdigital

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information