1 AYSIX-SAGE GAS MASS METERS FOR INDUSTRY Make the Wise Choice. Choose Aysix-Sage Flow Meters.
2 DEDICATION Aysix-Sage Metering is your source for monitoring, measuring and controlling the gas mass flow in your industrial process. Our high performance, NIST traceable, thermal mass flow meters will help you increase productivity, reduce energy costs, and maximize product yields. The Aysix- Sage Metering management team has over 80 years of combined experience in delivering quality in-line and insertion thermal mass flow meters for a wide variety of industrial needs and is dedicated to provide you with the performance and customer support that you deserve. Q U A L I T Y M A S S F L O W S U P P O R T P E R F O R M A N C E SIG Integral General Purpose SRG Remote General Purpose SIE Integral Explosion Proof HOW DOES THERMAL MASS MEASUREMENT BENEFIT YOU? Direct Mass Flow No need for separate temperature or pressure transmitters High Accuracy and Repeatability Precision measurement and optimal control of your process Rangeable over 100:1 Turndown (1000:1 with multiple calibrations) Accommodates the extremes of your process with one instrument Extreme Low-End Sensitivity Detects leaks, and measures flow, even on start-up (measures as low as 10 SFPM) Negligible Pressure Drop Will not impede the flow nor waste energy No Moving Parts Eliminates costly bearing replacements, and prevents undetected accuracy shifts Dirt Insensitive Rugged stainless steel sensors provide sustained performance Ease of installation, and convenient mounting hardware WHAT ARE THE BENEFITS THAT AYSIX-SAGE THERMAL MASS METERS OFFER YOU? New: Verify sensor operation and validate calibration with self-check routine New: Touch Display Screen Technology.The cover does not need to be opened to access Menuing System (actual changes are password protected and accessible by authorized personnel only). New: Lead-Length Compensation. Remote electronics up to 2000 feet from probe New: Probe Junction Box requires no electronics.suitable for harsh environments Available with up to four totally independent calibrations (four different gases, sensitivities, or configurations). Channels A D selectable by keypad, laptop or external switch closure Powerful microprocessor technology designed for high performance mass flow measurement and field rangeability Proprietary sensor drive circuit provides enhanced signal stability and provides extraordinary temperature compensation Menu driven user configurability, including full scale setting, units of measure, pipe area, channel selection, and diagnostics Easy to read 2-line back-lit flow rate/totalizer and temperature display. Also serves as dialog window for menu selection of user options RS232 PC interface and free navigational software (Aysix-Sage VIP) user friendly Flow conditioning built in to in-line flow meters (3/4 inch and up) Choice of explosion proof or general purpose, integral or remote electronics User-selectable relays (Trip High, Low or Pulsed Outputs) standard on Industrial product, optional on General Purpose (GP) product MULTIPLE CHANNEL CAPABILITY Four different gas calibrations in one meter (optional) Switch channels to switch sensitivities for greater than 1000 to 1 turndown (Channel A: 0-10 SCFM; Channel B: SCFM, etc. externally selectable) Ideal for Flare Gas applications Pre-configure for four different pipe sizes and full scale flow rates (i.e.: 2", 4, 6, 8") One meter can be a spare for dozens of differing applications: Simply select from four gas calibrations, enter pipe area, and enter full scale { 2 } AY S I X - S A G E M E T E R I N G
3 QUALITY AYSIX-SAGE THERMAL MASS METERS Aysix-Sage Thermal Mass Flow Meters are designed for high performance mass flow measurement of flow rate and consumption of gases such as air, oxygen, natural gas, nitrogen, digester gas, bio gas, flare gas, hydrogen, argon, carbon dioxide and other gases and gas mixes.they are field rangeable and have a convenient user interface. Our state-of-the-art, microprocessor technology features fault tolerant multiprocessors that transfer bi-directional system information via digital protocol (full duplex digital using SLIP protocol). This ensures a clean, error-free flow signal is transferred as high resolution digital data within the Aysix-Sage meter sub-systems which makes the unit virtually impervious to external analog noise. FEATURES AND BENEFITS The innovative Aysix-Sage design features an easyto-use menuing system, a large format mass flow, total and temperature display, and easy-to-use, Touch Display Screen, 4-button keypad to integrate the functions of flow measurement with your specific needs.you will have the flexibility to use the local display/keypad, or a laptop, to change configurations or to conduct basic diagnostics, including a calibration self-check, with the Aysix-Sage navigational software (Aysix-Sage VIP). At any time you can use the convenient menuing system to change full scale values, digitally filter the flow signal, change decimal points, set zero cutoffs, check diagnostics, or reconfigure an insertion meter for a different pipe size. In addition, you can order your meter configured for up to four different gas calibrations, and simply select the desired channel (A-D) at any time (e.g. four different gases, sensitivities, or configurations). Or you can order the meter calibrated for one gas (e.g. compressed air), but have it pre-configured for up to four different pipe sizes and full scales, so you can simply select the desired channel (A-D) based on the application. Channels are totally independent and each have their own full scale accuracy statement and settings. SIG Series Integral General Purpose Mass Flow Meter (In-Line Style shown). There are numerous other features built in to most Aysix-Sage Flow Meters. For example, continuous tracking of the highest and lowest mass flow rate with built in time and date stamps.this is a very practical feature for determining unusual peaks in a gas process, or for identifying excess usage by certain departments. Aysix-Sage meters provide the average flow rate for the prior hour at any time. If you require relay outputs, Aysix-Sage offers the option of two independent, 1 amp SPDT relays on the SIG and SRG Series that can be configured by laptop or keypad for a variety of settings (one relay is standard on the SIE or SRE Series), including trip-high, triplow (with or without delays), window alarms, pulsed outputs, timer outputs, etc. The Series SRG includes a more robust latched 9.3"x7.3" Fiberglass and Glass Windowed Remote Enclosure that can be mounted 2000 feet away from the sensor s measurement point.the 6-conductor cable separating the sensor probe (or flow body) from the electronics is lead-length compensated, allowing the user to change wire length without affecting the meter s accuracy or performance. In addition, the probe has an Explosion Proof Junction Box that does not require any electronics (all the electronics, as well as the meter display and menuing Touch Display Screen keypad, are in the Remote Enclosure).Thus, this easy-to-wire Junction Box is suitable for harsh environments (see photo on page 2). Aysix-Sage also offers an OEM version of our proven, high performance gas mass flow meter product line (Series SIL or SRL). Aysix-Sage Lite has many features of the standard product line, but does not have a display, does not have a menuing keypad, does not support multiple channels, and does not support relay outputs. However it has linear outputs of flow rate and temperature. It is offered in a 5x5x4 NEMA 4X enclosure, or Explosion Proof Enclosure, or as a single circuit board for customized end-user packaging. If there are any features that you require, or if you need application assistance, feel free to contact our local factory trained representative in your area. Refer to or phone the Aysix-Sage Sales or Service Staff to assist you ( ). PRINCIPLE OF OPERATION OF THE THERMAL MASS METER Aysix-Sage Thermal Mass Flow Meters have two sensors constructed of reference grade platinum windings (RTDs).The two RTDs are clad in a protective 316SS sheath and are driven by a proprietary sensor drive circuit. One of the sensors is self-heated (flow sensor), and the other sensor (temperature/reference sensor) measures the gas temperature.the pair is referred to as the sensing element, and is either installed in a probe as an Insertion style, or inserted into a pipe section as an In-Line style flow meter. As gas flows by the flow sensor, the gas molecules carry heat away from the surface, and the sensor cools down as it loses energy.the sensor drive circuit replenishes the lost energy by heating the flow sensor until it is a constant temperature differential above the reference sensor.the electrical power required to maintain a constant temperature differential is directly proportional to the gas mass flow rate and is linearized to be the output signal of the meter. It is essential that this constant temperature differential be maintained, even if there are wide fluctuations in gas temperature. It is the job of the Aysix-Sage proprietary sensor drive circuit to maintain the differential, whether or not the gas temperature changes, or however quickly molecules cool off the flow sensor. It is also necessary to properly calibrate the device with the actual gas (or close equivalent with certain gases), in the Aysix-Sage National Institute of Standards certified (NIST) calibration facility. By accomplishing these two critical objectives, the Aysix-Sage meters provide an extremely repeatable (0.2% of full scale) and accurate output directly proportional to the mass flow rate of the gas being measured. AY S I X - S A G E M E T E R I N G { 3 }
4 GENERAL SPECIFICATIONS FOR AYSIX-SAGE MASS METERS GENERAL Function: Microprocessor-based Insertion or In-Line Mass Flow Meters for gases Flow Element: Constant Temperature Thermal Mass Flow Element consists of two 316 SS clad platinum-wound RTDs Flow Rate Output Signal 7 : 4-20mA isolated linear flow signal on all products. Pulsed outputs optional 8 Temperature Output Signal 7 : 4-20mA isolated linear temperature signal from 40 F to 200 F (-40 F to 750 F optional) is second output on SIG & SRG Series; menu selectable in lieu of flow outputs on SIE & SRE Series. A second temperature output is also available on the SIL and SRL Series, but it is 0 5VDC linear instead of 4 20mA. Communication: RS232. (Ethernet pending) Sensor Drive Circuit: Proprietary Sensor Drive Circuit provides enhanced flow signal stability and insensitivity to process temperature changes Display: 2-line LCD back-lit Flow Rate (top line),total and Temperature (bottom line) is standard on all Mass Flow Meters (except for SIL and SRL Series which have no displays). Menu Navigation: 4-Button Touch Display Screen 9 Keypad (except SIL & SRL) and RS232 with navigational software (Aysix- Sage VIP) standard (software optional on SIL & SRL).With Touch Display Screen technology, the cover does not need to be opened to access Menuing System. Multiple Channel Capability: Up to four totally independent calibrations available on all products except SIL & SRL. Calibrate for four different gases, different sensitivities, and/or different configurations (Channels A D).Channels can be keypad, laptop or externally selectable (via contact closures). Power: 24VDC (250 ma with back light off, 350mA max with back light on), 115VAC or 230VAC (Switchable) on SIG & SRG Series. 250mA max on SIE, SRE, SIL or SRL Series RANGE / SIZES Units of Measurement: Flow SCFM, SCFH, SCFD, SCCM, NCMM, NCMH, KG/S, KG/M, KG/H, KG/D, LBS/S, LBS/M, LBS/H, LBS/D, SLPM, SLPH; Velocity SFPM, SFPS, NMPM, NMPS, NMPH (other combinations available); Temperature C and F Insertion Meters: Full Scale up to 35,000 SFPM (i.e., up to 12,000 SCFM in an 8" Sch. 40 Pipe). Higher velocities optionally available. Resolve as low as 10 SFPM. Standard probe is 1/2" diameter, with optional 3/4". Standard lengths are 6", 12", 15", 18" or 24" and optional up to 48" In-Line Meters: Full Scale up to 3150 SCFM (4" Flow Meter). Resolve as low as.006 SCFM (3/8" Flow Meter). Male NPT fittings standard. 150# and 300# flanged ends optional. (See chart below) PERFORMANCE Standard Flow Accuracy 6 : +/-1% of Reading +0.5% of Full Scale over 100: 1 turndown. (Contact Aysix-Sage for special accuracy) Repeatability: 0.2% of Full Scale Turndown: 100:1 of Full Scale minimum (1000:1 with multiple channels) Calibration: Aysix-Sage Metering s National Institute of Standards Traceable (NIST) calibration facility Gas Temperature: Std.: -40 F to 200 F (-40 C to 93 C ); HT01: 200 F to 350 F (93 C to 177 C ); HT02: 350 F to 500 F (177 C to 260 C); HT03: 500 F to 750 F (260 C to 399 C) Integral or Remote Enclosure Temperature: 0 to 150 F (-18 C to 65 C ). Contact Aysix-Sage for lower temperature ranges. Note: Remote Enclosure can be mounted up to 2000 feet away to locate in a suitable temperature environment Pressure Rating: 500 psig (1000 psig optional) Response Time: 1 second (each time constant) for flow change Subsystem Interface: Full duplex digital using SLIP protocol ENCLOSURES Integral General Purpose, Integral Explosion Proof, Remote General Purpose, and Remote Explosion Proof. Remote styles do not require electronics at sensor Junction Box. (See dimensional drawings on page 5 for classifications.) DISPLAY / KEYPAD General Purpose SIG & SRG Transmitter have large format 2 x 16 LCD back-lit display with large format 4-Button Keypad. Explosion Proof SIE & SRE Transmitter has 2 x 16 small format back-lit display with standard 4-Button Keypad. (SIL & SRL transmitter are blind.) Keypad uses Touch Display Screen Technology on General Purpose Meters (SIG & SRG) and can be activated without removing cover. WETTED PARTS 316L Stainless Steel for Flow Bodies, Sensor Flow Elements and Flow Conditioners. Hastelloy (recommended for Chlorine Gas) and other materials optional. CONDITIONING All In-Line Flow Meters 3/4 inch and above include built-in flow conditioning. RELAYS Two 1-amp relay channels (each SPDT) optionally available on SIG & SRG Series. One 1-amp relay is standard on SIE & SRE Series. Menu configurable (see description under Aysix-Sage Thermal Mass Flow Meters on page 3). AGENCY APPROVALS CSA and UL. Contact Aysix-Sage or visit our website ( for details. ETHERNET COMPATIBILITY Pending: Ethernet 10Mb/s or ID base-t via RJ-45 Cat 5 cable. Contact Aysix-Sage or visit our website ( for details. LIMITED WARRANTY Aysix-Sage Metering's Series of Thermal Mass Flow Meters are warranted against faulty materials or workmanship for one year from the date of delivery to the buyer. After issuance of a Return Meter Authorization (RMA) by Aysix-Sage, and upon receipt of the defective meter, Aysix-Sage will either repair or replace the defective meter at its sole option and at no cost to the purchaser. PLEASE NOTE Performance specifications are effective with date of issue and are subject to change without prior notice.the metering devices and other equipment pictured in this brochure are for identification and illustration purposes only.the appearance and dimensions of the actual products may differ slightly from those shown but will perform as represented. Aysix-Sage Metering reserves the right, at any time, to make such modifications and changes to the products shown herein as it deems appropriate, without prior notice to the customer. Pipe Size x Flow Body Length 1 or Flange (Face-to-Face) 3/8" x 6" 1/2" x 7" 3/4" x 7" 1" x 8" 1-1/4" x 10" 1-1/2" x 12" 2" x 15" 2-1/2" 2" x 15" 18" 3" x 20" 4" x 25" Model 2 Minimum Resolution Typical FS 3 (Standard Cubic Feet (Standard Cubic Feet per Minute 5 ) per Minute 5 ) S( ) S( ) S( ) S( ) S( ) S( ) S( ) S( ) S( ) S( ) Max FS 4 (Standard Cubic Feet per Minute 5 ) Flow Conditioning Built in to Flow Meter Pipe Sizes 3/4" and up. Contact Aysix-Sage for optional 1/4" tube flow body 2 ( ) determined by type of style and enclosure (i.e., SRG: Remote Style, General Purpose Enclosure) 3 Full Scale (FS) can be specified as low as 1/10 of typical full scale to retain 100:1 turn down. For example, a 3/4" Meter can be specified as high as SCFM, or as low as 0-6 SCFM, or anything in between (i.e., 0-40 SCFM) 4 Max Full Scale available for many gases, such as pressurized Air or Nitrogen. Some gases such as Hydrogen may be limited to the Typical FS value. Calibrations above 500 SCFM may be extrapolated. 5 1 SCFM 1.7 NCMH. Aysix-Sage standard conditions for calibration are 70 F and 29.92" Hg. 6 At zero or low flow, meter(s) may experience a slight pressure sensitivity 7 The SIL & SRL Series has two outputs, a 4-20mA and a 0-5VDC signal. They each can be configured for either flow or temperature. 8 Pulsed outputs of Totalized Flow are configurable when relay(s) are present.two relays are optional on SIG & SRG, one relay is standard on SIE & SRE, but none are available on SIL & SRL. 9 Touch Display Screen not available on SIE or SRE Series { 4 } AY S I X - S A G E M E T E R I N G
5 DETAIL DIMENSIONAL DRAWINGS FOR SAGE MASS METERS A CORD GRIP COMPRESSION FITTING Note: Flanged Flow Bodies Optional 11 (All Dimensions in Inches) 5.03 C CORD GRIP COMPRESSION FITTING 3.00 dia 25' CABLE SUPPLIED Can be shortened or even lengthened in the field by up to 2000' without JUNCTION BOX (XP1) affecting calibration Explosion Proof (Cast Aluminum) (No Electronics Required) ' CABLE SUPPLIED Can be shortened or even lengthened in the field by up to 2000' without affecting calibration 4.69 B NPT Fittings standard (150# or 300# flanges optional) 2 Flanged Mounting available for high pressure operation 4 10" nominal when collar clamps are together 5 Safety chain is sized depending on probe length to prevent probe from escaping above compression fitting. 6 At 650 psig, force exerted on 1 2 diameter probe is approx. 125 psig. 7 3/4" Female NPT access holes for wiring (conduit compatible) 8 Access holes are 1 2" NPT (supplied capped) 9 All NEMA 4X Enclosures have 4" depth dia SIG SERIES INTEGRAL GENERAL PURPOSE MASS METER In-Line Style1, 8, 9 NEMA 4X Enclosure (ABS Plastic). 150# or 300# flanged ends are optionally available. (1" Flow Body shown) SIG SERIES INTEGRAL GENERAL PURPOSE MASS METER Insertion Style2, 8, 9 NEMA 4X Enclosure (ABS Plastic). 150# or 300# flanged mounting is optionally available. Available probe lengths (C) are 6", 12", 15", 18", 24", 30", 36" or 48". SRG SERIES REMOTE GENERAL PURPOSE MASS METER Insertion Style2, 8, 9 (Also available as In-Line Style) NEMA 4X Enclosure (Fiberglass 14 ). 150# or 300# flanged mounting is optionally available. Available probe lengths (C) are 6", 12", 15", 18", 24", 30", 36" or 48". SRL SERIES REMOTE LITE (BLIND) MASS METER Insertion Style2, 8, 9, 10 (Also available as In-Line Style) NEMA 4X Enclosure (ABS Plastic). 150# or 300# flanged mounting is optionally available. Available probe lengths (C) are 6", 12", 15", 18", 24", 30", 36" or 48". SIL SERIES INTEGRAL EXPLOSION PROOF 12 (BLIND) MASS METER In-Line Style 1, 8 (Also available as Insertion Style) Explosion Proof Enclosure (Cast Aluminum), Class I, Division I, Group C, D. 150# or 300# flanged ends are optionally available. (1" Flow Body shown) 10 Circuit board available separately, 3" diameter. 11 When flanges specified, face-to-face dimensions same as Length on Table on page All Explosion Proof Meters are Class I, Group B, C, D, Class II Group E, P, G and Class IV and have Cenelec, EExd Enclosure IIC, IP66 ratings and are NEMA 4X, 7BCD and 9EPG rated. (All Junction Boxes, when applicable, are Class I, Group C & D; Class II, Group E, F, G, and NEMA 7 and NEMA 9 rated.) 13 Used for pressures to 650 psig (shown for use with 1 2" x 3 4" NPT and 3 4" x 1" NPT. 14 Other materials available C dia Pipe Size 3/8" 1/2" 3/4" 1" 1-1/4" 4.69 B Gen. Purpose (A) 8.09" 8.15" 8.28" 8.40" 8.53" ' CABLE SUPPLIED Can be shortened or even lengthened in the field by up to 2000' without affecting calibration IN-LINE METER DIMENSIONS Flow Body Length Shown on Page 4 SAFETY CHAIN 5 Expl. Proof (B) 7.39" 7.45" 7.58" 7.70" 7.83" COMPRESSION FITTING ISOLATION VALVE 3/4" WELD-LET DISPLAY DISPLAY JUNCTION BOX (XP1) Explosion Proof (Cast Aluminum) (No Electronics Required) Pip e S ize 1-1/2" 2" 2-1/2" 3" 4" Gen. Purpose (A) 8.65" 8.90" 9.15" " Expl. Proof (B) 7.95" 8.20" 8.45" 8.70" 9.20" SIE SERIES INTEGRAL EXPLOSION PROOF 12 MASS METER In-Line Style 1, 7 Explosion Proof Enclosure (Cast Aluminum). Class I, Division I, Group B, C, D. 150# or 300# flanged ends are optionally available. (1" Flow Body shown) SIE SERIES INTEGRAL EXPLOSION PROOF 12 MASS METER Insertion Style 2, 7 Explosion Proof Enclosure (Cast Aluminum). Class I, Division I, Group B, C, D. 150# or 300# flanged mounting is optionally available. Available probe lengths (C) are 6", 12", 15", 18", 24", 30", 36" or 48". SRE SERIES REMOTE EXPLOSION PROOF 12 MASS METER In-Line Style 1, 7 (Also available as Insertion Style) Explosion Proof Enclosure (Cast Aluminum). Class I, Division I, Group B, C, D. 150# or 300# flanged ends are optionally available. (1" Flow Body shown) (Optional Mounting Brackets available) SVA SERIES ISOLATION VALVE ASSEMBLY MOUNTING HARDWARE FOR INSERTION METERS 13 The Isolation Valve Assembly permits insertion or removal of probe without shutting down the gas line. STCF SERIES TEFLON FERRULE COMPRESSION FITTING MOUNTING HARDWARE 1/2" tube x 1/2" pipe fitting (shown, not to scale), is used for low pressure insertion applications to 125 psig (Stainless Steel Ferrule optional for higher pressure applications up to 225 psig). Also available in 3/4" tube x 3/4" pipe size. AY S I X - S A G E M E T E R I N G { 5 }
6 Compressed Air Monitoring Monitor Plant Nat. Gas Consumption Natural Gas Distribution Specialty Gas Monitoring Flare Gas Wastewater Treatment Water Purification Incineration Combustion Control Tablet and Pill Coating Nitrogen Blanketing Fuel Cells Landfill Gas Testing Hydrogen Cooled Turbines Fiber Optics Production Plastic Production Fiberglass Production Pump Manufacturing Natural Gas Furnace Steel Fabrication Metals Recovery Plastics Molding Spray Drying Aluminum Smelters Remediation Powder Painting Heat Treating Glass Manufacturing Pulp and Paper Food Process Coal Fired Power Plant Nitrogen Purge Leak Detection APPLICATIONS COMMON APPLICATIONS FOR AYSIX-SAGE THERMAL MASS METERS Perform Audits Detect Leaks Sub-Meter for Conservation Plant Monitoring Sub-Metering Check Meters Source Control Nitrogen and Argon Plant Metering Nitrogen and Argon Sub-Metering Nitrogen, Argon & Hydrogen Consumption Exhaust Flow Aeration Flow Digester Gas Biogas Odorizing Oxygen Monitoring Exhaust Flow Natural Gas, Oxygen, Air Flow Monitor Atomizing Gas Monitor Exhaust Gas Tank Blanketing Surface Blanketing Air Flow Hydrogen Flow Methane CO2 Mix Hydrogen Leak Detection Chlorine Flow Rate Argon, Nitrogen Flow Combustion Control Test Pumps Natural Gas Consumption Argon and Nitrogen Flow Rate Coke/Oven Gas Air Flow Rate Nitrogen Flow Uniform Air Flow Natural Gas and Air Flow Chlorine and Argon Flow Air Flow Painting Cars with Robotics Air Flow Combustion Control Drying Air Flow Hydrogen Flow Nitrogen Flow Primary and Secondary Air Flow Exhaust Flow Nitrogen Flow Rate Low Air Flow Rate Improve overall cost effectiveness of compressed air system Eliminate waste Improve efficiency of overall system Reduce energy expense Track billing meter, assess daily flow peaks, determine demand for each shift Monitor department usage, and analyze associated expenses Natural gas distribution lines require check meters to measure usage (downstream of gate valves) Monitor NG exhaust (Dual Channel Meters Low Flow and High Flow) Monitor flow rate and consumption of N2, AR and other specialty gases in a plant s gas distribution system Sub-Meter N2, AR, etc. by department to determine cost savings Totalize mass flow for customer billing Monitor normal and upset condition (Dual Channel Meters) Monitor individual flare header pipes Monitor and adjust the air flow bubbling into aeration tanks to control the critical dissolved oxygen level Monitor the flow of CH4/CO2 mix in the digesters to facilitate the sewage treatment Measure the excess gas for storage as backup fuel, and monitor emissions Monitor Oxygen flow in odorizing (fragrancing) Monitor O2 flow rate in ozone generator systems that purify municipal water supplies Measure exhaust flow in incinerators Monitoring and controlling of combustion air or oxygen and natural gas ratios are critical for optimal boiler efficiency Stoichiometric ratio control Monitor the atomizing air or nitrogen flow rate in the pharmaceutical pill coating process Monitor the flow rate of the downstream side of the pill coating process to determine the by-product emission Measure the nitrogen flow layering over the contents of the tank to insulate the product Move product, such as pills, along a layer of nitrogen on a conveyer. Fluidized beds Monitor the air flow to control the efficiency of fuel cell power plants Monitor the hydrogen generated in the fuel cell process Monitor gas to engines for electrical power Measure air flow rate that is analyzed for hydrogen presence Measure flow rate of chlorine with Hastelloy sensor for fiber optic production efficiency Monitor AR & N2 flow rate involved in certain plastics production Monitor flow rate of natural gas and oxygen to control air-fuel ratio to optimize burners resulting in higher quality product and greater product yields Monitor air flow to test pumps for manufacturing quality control Measure NG consumption for furnaces that burn NG in a nitrogen environment Monitor and control AR & N2 flow rate for bottom stirring and purification Monitor the refined end of the coke oven gas process Air flow rate is critical in forming bubbles that capture precious metals that otherwise are not recoverable Nitrogen flow rate controls the forming of plastic shapes such as gas tanks Monitor air flow to uniformly dry components in pharmaceutical, food processing, fertilizer and chemical industries Combustion control for boilers and furnaces Hastelloy flow meter monitors the CL2 and AR in the smelting process Meter the air intake used to detect contaminated soil Monitor air flow, including turbine air, atomizing air and shaping air to control automotive paint quality Monitor air flow in heat treating furnaces to improve quality Monitor oxygen and natural gas flow to control burners for optimal glass production Improve product quality by monitoring drying air flow Hydrogen flow rate involved in producing vegetable oil Nitrogen flow measurement for food preservation Monitoring the primary & secondary (reheat) air flow in coal fired utilities for boiler efficiency Monitor stack exhaust for environmental compliance Numerous processes require a purging of the process to clear out residual gases and contamination. Measuring small amounts of air flow detects product flaws in many industries, including filter manufacturing { 6 } AY S I X - S A G E M E T E R I N G
7 VERSATILITY AYSIX-SAGE GAS MASS METERS CONFIGURED FOR ANY APPLICATION Your Pipe Size 3/8 1/2 3/ /4" 1-1/ /2" >36 Example of a Model Number Aysix-Sage In-Line Meters S( )-030 S( )-050 S( )-075 S( )-100 S( )-125 S( )-150 S( )-200 S( )-250 S( )-300 S( )-400 S I G S VA A C N G Base Model Probe (i.e., I=Integral, Diameter G=General Purpose) Probe Length Mounting Hardware Power Gas Aysix-Sage Insertion Meters S( ) S( ) S( ) Consult Factory Building a Model Number 1. Select Style Integral (I) or Remote (R) General Purpose (G), Explosion Proof (E) or Aysix-Sage Lite (L) In-Line (-XXX) or Insertion (-XX-XX) 2. If In-Line, select pipe size (see table on page 4 for Flow Body Length) 3. If Insertion, select probe diameter, and length [(-05 = 1/2" tube (standard); -07 = 3/4" tube (optional)] 4. Select probe length based on mounting hardware choice (the chart assumes utilizing Sage Isolation Valve Assembly mounting hardware) -12 = 12" length; -15 = 15" length -18 = 18" length; -24 = 24" length -06 = 6" length (assumes utilizing Aysix-Sage Teflon Compression Fitting mounting hardware) 5. If Insertion, select mounting hardware (Valve or Compression Fitting) SVA05 = Aysix-Sage Isolation Valve Assembly for 1/2" probe SVA07 = Aysix-Sage Isolation Valve Assembly for optional 3/4" probe STCF05 = Aysix-Sage Teflon Compression Fitting for 1/2" probe SSCF05 = Aysix-Sage Stainless Steel Compression Fitting for 1/2" probe STCF07 = Aysix-Sage Teflon Compression Fitting for optional 3/4" probe 6. Select operating voltage: -DC24 = 24VDC; -AC115 = 115VAC; -AC230 = 230VAC 7. Add symbol of gas being measured at end of part number 8. Add Options (such as RG2: Dual Range; LG1: Large Fiberglass Enclosure; XP1: Explosion Proof Junction Box) 9. Include Full Scale Flow Rate and operating temperature and pressure in description This model number describes a Aysix-Sage Integral Style General Purpose Insertion Mass Flow Meter for Natural Gas with a Sage Isolation Valve Assembly, 1/2" x 15" long probe, and 115VAC power This diagram depicts the various styles INTEGRAL GENERAL PURPOSE REMOTE GENERAL PURPOSE 2 IN-LINE INSERTION IN-LINE INSERTION currently offered by Aysix-Sage Metering including General Purpose, Explosion Proof and Remote Configurations. S I G - X X X S I G - X X - X X S R G - X X X S R G - X X - X X INTEGRAL EXPLOSION PROOF REMOTE EXPLOSION PROOF IN-LINE INSERTION IN-LINE INSERTION 1 Lite refers to Aysix-Sage Lite Product Line for OEM customers (consisting of blind enclosures) or optionally offered as a single round circuit board only. Also available upon request with explosion proof enclosures. 2 Remote General Purpose style has an Explosion Proof Junction Box (with no electronics) as well as the General Purpose (NEMA 4X) Remote Fiberglass Enclosure. S I E - X X X S I E - X X - X X INTEGRAL LITE 1 GENERAL PURPOSE IN-LINE INSERTION S R E - X X X S R E - X X - X X REMOTE LITE 1 GENERAL PURPOSE IN-LINE INSERTION S I L - X X X S I L - X X - X X S R L - X X X S R L - X X - X X AY S I X - S A G E M E T E R I N G { 7 }
8 Make the Wise Choice. Choose Aysix-Sage Flow Meters. SALES REPRESENTATIVE 2595 Dunwin Drive, Unit #2 Mississauga, ON L5L 3N9 Phone: Fax:
SAGE GAS MASS FLOW METERS
SAGE GAS MASS FLOW METERS FOR INDUSTRIAL & ENVIRONMENTAL APPLICATIONS Make the Wise Choice. Choose Sage Flow Meters. DEDICATION Sage Metering is your source for monitoring, measuring and controlling the
More informationMTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
More informationF ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems
F ox W hi t e Paper Reduce Energy Costs and Enhance Emissions Monitoring Systems A Technical White Paper from Fox Thermal Instruments Rich Cada, VP Sales & Marketing, Fox Thermal Instruments, Inc. 399
More informationThermal Mass Flow Meter (Series MST)
Overview MaxiFlo TM MST series Thermal Mass Flow Meter is the instrument of choice for reliable and accurate measurement of mass flows for various gases. It measures the mass flow of gas based on constant
More informationMass Flow Meter Product Guide
Mass Flow Meter Product Guide 2 thermal Mass technology Kurz Instruments manufactures thermal mass flow meters designed to accurately monitor and measure dry air, dry gas, and wet gas environments. Thermal
More informationThermatel Model TA1 Mass Flow Transmitter
Thermatel Model TA1 Mass Flow Transmitter D E S C R I P T I O N Thermatel Thermal Mass Flow Transmitter, Model TA1, provides a high level of performance in mass flow measurement of air and gases. Powerful
More informationFCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications
FCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications Flow Measurement Flow Switches Level Switches Level Interface Switches FCI OEM SERIES Industrial Machinery Chemical Injection
More informationElectronic Flow Switches
Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
More informationSanitary Type Electronic Flow Switches
Industries Pharmaceutical Sanitary Type Electronic Flow Switches Food and Beverage Biotechnology Semiconductor Water Treatment S Series Ameritrol, Inc. Instruments and Controls Features No Moving Parts
More informationIn-Line Electronic Flow Switches
In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
More informationThe Unique Accelabar Flow Meter
The Unique Accelabar Flow Meter The Accelabar is a new and unique flow meter that combines two differential pressure technologies to produce operating ranges never before attainable in a single flow meter.
More informationGalvanic Parts Per Million Dissolved Oxygen Systems
Galvanic Parts Per Million Dissolved Oxygen Systems Model 900 Portable s Model 9100 Model 9200 Model 9300 The Royce line of PPM level dissolved oxygen (DO) analyzers is the largest, most varied line in
More informationThermatel Enhanced Model TA2 Thermal Mass Flow Meter
Thermatel Enhanced Model TA2 Thermal Mass Flow Meter D E S C R I P T I O N The Thermatel Enhanced Model TA2 Thermal Mass Flow Meter provides reliable mass measurement for air and gas flow applications.
More informationFor Multi-Parameter Meters see mvx
BULLETIN BULLETIN EM20607 VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up
More informationFLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)
FLARE MONITORS Infrared Sensors for Monitoring Smokeless Flares, Pilots, and Flame Intensity FMDS2014 FLARE MONITOR (FM) Monitor smokeless flare combustion efficiency to maximize destruction of hazardous
More informationCOMBIMASS. Technical Data COMBIMASS eco-bio +
COMBIMASS Technical Data THE SYSTEM COMBIMASS The field transmitters of the COMBIMASS eco series are suitable for gas flow measurement and cover a wide range of different applications. The instruments
More informationO C M III. Open Channel Flow Monitor
O C M III Open Channel Flow Monitor Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic flow transmitter with sensor and temperature compensation probe. B. Under this
More informationFCI ST75 Series Flow Meters
FCI ST75 Series Flow Meters Small Line, Mass Flow Meters for Industrial and Commercial Process Gases Low cost, easy installation flow measuring for 1/4 inch to 2 inch [6 mm to 51 mm] line sizes FCI ST75
More informationThermal Mass Flow Meters
Thermal Mass Flow Meters for Greenhouse Gas Emissions Monitoring Natural Gas Measurement for Emissions Calculations Flare Gas Monitoring Vent Gas Monitoring Biogas and Digester Gas Monitoring Landfill
More informationAeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson
Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology HWEA 2011 Conference Craig S. Johnson Presentation Overview Introduction Aeration Air & Digester gas challenges Gas flow metering
More informationHow To Use A Ds340 (Dsp)
Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions
More informationInterface Level And Point Level Analyzers & Sensors
Interface Level And Point Level Analyzers & Sensors Model 2511 Analyzer Model 2505 System Model 2120 System Royce now offers a complete line of Interface Level and Point Level Analyzers that make it possible
More informationEnvironmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000
IMR 5000 Continuous Flue Gas Monitoring System The IMR 5000 is state-of-the-art continuous flue-gas monitoring system, and is designed for a wide variety of flue-gas monitoring applications. The IMR 5000
More informationred-y smart series product information Thermal Mass Flow Meters and Controllers for Gases
red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases Reliable and accurate: Thermal Mass Flow Meters and Controllers Reliable technology and industry standard interfaces
More informationAirflow Sensors Line Guide
Airflow Sensors Line Guide Go with the flow of engineering leadership. All airflow sensors operate on heat transfer flow and differential pressure. But Honeywell Sensing and Control (S&C) offers advanced
More informationDREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly
DREXELBROOK A Leader In Level Measurement Solutions USonic-R Series Ultrasonic Level Measurement System User Friendly Set the measurement range directly in inches, feet, millimeters, centimeters, or meters
More informationTake total control of your HVAC system with cost-saving flow and thermal energy meters
Take total control of your HVAC system with cost-saving flow and thermal energy meters Because you can t manage what you don t measure usa.siemens.com/pi Answers for Industry. Contents Introduction 03
More informationCAMS. Combustion Airflow Management System. Proven solutions for a tough industry
CAMS Combustion Airflow Management System Proven solutions for a tough industry CAMS TM Combustion Airflow Management System Product Description The Air Monitor Power CAMS TM Combustion Airflow Management
More informationwww.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter
www.kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter Description The KVO Vortex flow meters utilize two primary sensing elements a vortex shedding
More informationThermal Dispersion Mass Flow
Thermatel Thermal Dispersion Mass Flow Measurement Handbook Table of Contents Introduction...1 What is Mass Flow Measurement?...1 Types of Flow Transmitters...4 Differential Pressure...4 Orifice...4 Venturi...6
More informationReliability Accuracy Performance
FCI flow switch guide Reliability Accuracy Performance eliability, accuracy and performance are the key product features required by FCI customers for their flow, level and temperature switch applications.
More informationS300 Series Dust Monitors
S301 DustGuard S303 Trend Monitor S304 Emission Monitor S305 Stack Monitor Intrinsically Safe (ATEX) Dust Monitors Split Architecture (Remote)Models Data Logging Software S300 Series Dust Monitors Dust
More informationFMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters
FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters M-4270/0707, pg. 2 of 29 READ THIS MANUAL COMPLETELY BEFORE ATTEMPTING TO CONNECT OR OPERATE YOUR FLOW SENSOR. FAILURE TO DO SO MAY
More informationRHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
More informationLaminar Flow Elements
Laminar Flow Elements Meriam Laminar Flow Elements (LFEs) are excellent for measuring low gas flow rates from 0.2 SCCM up to 2250 SCFM. They are inherently accurate and repeatable and are calibrated traceable
More informationContinuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors www.static-control.in 1 Introduction The detection or monitoring of flue gases and or hazardous gases has been a complex subject
More informationSection: R100 Bulletin: R100.51 Date: 07/13 Supersedes: New TRUST. Your Water Level. Steam you can depend on, 24/7. Boiler Level Indication System
Section: R100 Bulletin: R100.51 Date: 07/13 Supersedes: New TRUST Your Water Level Steam you can depend on, 24/7 Boiler Level Indication System Boiler Level Indication System Where s your water? For over
More informationOperations and Instruction Manual For Prime Models SIP and SRP
SAGE THERMAL GAS MASS FLOW METER Operations and Instruction Manual For Prime Models SIP and SRP DOCUMENT NUMBER 100-0065 REVISION 15 - SIP/SRP (SAGE PRIME ) Make the Wise Choice. Choose Sage Flow Meters.
More informationElement D Services Plumbing
Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.
More informationImmersible Thermal Gas Mass Flow Meter FeaTures DescrIpTIon
Immersible Thermal Gas Mass Flow Meter Features n Direct mass flow monitoring eliminates need for separate temperature and pressure inputs n Accuracy +/- 1% of reading plus 0.5% of full scale n Patented
More informationTypical Aluminum GFM Mass Flow Meter
MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.
More informationDigitalFlow GF868. Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range. GE Sensing & Inspection Technologies.
GE Sensing & Inspection Technologies DigitalFlow GF868 Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range Applications The DigitalFlow GF868 flowmeter is a complete ultrasonic
More informationJNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
More informationPump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.
Pump_PT580 Optional PT580-CFG PCM370 Optional DTM96 Buffered Dual Relay Remote Reset Local Display Condition Monitoring System PLC/DCS PT580 Digital Vibration Switch Introduction The PT580 Digital Vibration
More informationPIEZOMETER AIRFLOW MEASURING RING
PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer
More informationRI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
More informationOWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
More informationTYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output
133-683 JUNE 28, 2006 TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output DESCRIPTION APPLICATION The Fireye 65UV5-1004 flame scanner is a microprocessor based flame
More information! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)
Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions
More informationETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
More informationF-5100 Inline Thermal Mass Flow Meter Installation and Operation Guide
F-5100 Inline Thermal Mass Flow Meter Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax (727) 442-5699 0686-10 / 18332 www.onicon.com sales@onicon.com
More informationMass Flow Meters & Controllers
HFM-D-3A & 305A Mass Flow Meters HFC-D-3A & 307A Mass Flow Controllers FEATURES Range 0-25 slm to 0-2500 slm (N 2 Equivalent) Excellent Accuracy ±(0.5% of Reading + 0.2% of Full Scale) 0-5 VDC or 4-20
More informationEuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases
Product information EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Proven Analyzer Technology Measuring total hydrocarbons
More informationFeatures Direct mass flow monitoring eliminates need for separate temperature and pressure inputs. Accuracy +/- 1% of reading plus 0.
Immersible Thermal Gas Mass Flow Meter Features Direct mass flow monitoring eliminates need for separate temperature and pressure inputs Accuracy +/- 1% of reading plus 0.5% of full scale Patented Dry-Sense
More informationManual for Fire Suppression & Methane Detection System
Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327
More informationSide-Trak 830/840. Process Gas Mass Flow Meters and Controllers. www.sierrainstruments.com
Process Gas Mass Flow Meters and Controllers Features n Direct monitoring of mass flow eliminates need for ancillary pressure and temperature sensing n Patented straight sensor tube with access ports permits
More informationProduct Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com
Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer
More information713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.
and Transmitter All-in-one package for open channel flow measurement. 3.1 NEW Class 1, Division 1 Approved Sensor As our products are continuously improved, we reserve the right to make any change in the
More informationIn-Line Electronic Flow Switches
In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
More informationNirvana. Cycling Refrigerated Dryers
Nirvana Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Reliability Is Our Design Ingersoll Rand's Nirvana Cycling Refrigerated Dryer provides reliability like no other dryer in its class:
More informationPRODUCT PROFILE FEATURES
PRODUCT PROFILE Pressure Transmitters & Pneumatic Transducer Airflow Transmitter, Differential Air Pressure Transmitter and Differential & Gauge Liquid/Gas Pressure Transmitter FEATURES AIRFLOW TRANSMITTER
More informationAdvantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
More informationBoiler Control Solution. Boiler Control Solution. Instruments and Solution for Automatic Boiler Control LF3BUSS02-00EN. www.yokogawa.
Boiler Control Boiler Control Instruments and for Automatic Boiler Control LF3BUSS02-00EN www.yokogawa.com Best for Automatic Boiler C Sensors and controllers for the efficiency and environmental performance
More informationBLUE RIBBON CORP. BC001 Birdcage Installation Manual
Product Overview: This manual is applicable for the BC001 Birdcage Submersible Level Transmitters. If the product you have has a different prefix part number than listed above please contact the factory
More informationPolyGard Carbon Monoxide CO Transmitter ADTX3 1110
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 DESCRIPTION CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air
More informationBB-18 Black Body High Vacuum System Technical Description
BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The
More informationMicro Motion 3098 Gas Specific Gravity Meter
Product Data Sheet PS-001161, Rev. D April 2013 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.
More informationC. Burner management system to follow requirements of Industrial Risk Insurers (IRI).
SECTION 23 52 30 PART 1 - GENERAL 1.01 RELATED WORK A. Section 23 05 00: Common Work Results for HVAC B. Section 23 25 00: Chemical Water Treatment C. Section 23 51 23: Flue Piping 1.02 QUALITY ASSURANCE
More informationSECTION 23 90 13 NOx, CO AND NATURAL GAS DETECTION, MONITORING AND ALARM CONTROL SYSTEMS
SECTION 23 90 13 NOx, CO AND NATURAL GAS DETECTION, MONITORING AND ALARM CONTROL SYSTEMS PART 1 - GENERAL 1.01 Section Includes A. Requirements for provision of the Natural Gas (CH4), Carbon Monoxide (CO)
More information1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;
1/11 CO2 DOSAGE SYSTEMS CO2 dosage system consists of following parts; 1 - O2 trim system with micro processing burner (automatic combustion monitoring), 2 - Other components of O2 trim system, 3 - CO2
More informationWater Leak Detection System
Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:info@rodisystems.com 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright
More informationEnergy and Flow Measurement for Hydronic Systems
Energy and Flow Measurement for Hydronic Systems Presented By: George Szyszko Applications Consultant MCR for ONICON Incorporated Why Measure Thermal Energy? To control something, you must first measure
More informationB-Series Temperature Switches
FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage-treatment
More informationRegards from the Team at Rheology Solutions.
Rheology Solutions is the sole Australian distributor of this product range and we welcome the opportunity of discussing your application requirements. We hope the information you are seeking is contained
More informationGeneral Purpose ph/orp Sensors
General Purpose ph/orp Sensors Product Data Sheet LIQ_PDS_3900 / Rev. F December 2014 General Purpose ph/orp Sensors SMART preamplifier-stores calibration and other data. Extended sensor life provided
More informationCOMBIMASS. Thermal gas flow measurement system. For measuring and balancing of normal volumetric or gas mass flows
COMBIMASS Thermal gas flow measurement system For measuring and balancing of normal volumetric or gas mass flows COMBIMASS The COMBIMASS series enables direct measurement of the normal volumetric flow
More informationRM7000 TC with Internal Pulser
RM7000 TC with Internal Pulser STANDARD COUNTER (STD CTR) STD CTR meters register the non-compensated, displaced gas volume in actual cubic feet (cf). The meter module is available with either a side or
More informationDigitalFlow GF868 Panametrics Ultrasonic Flare Gas Mass Flowmeter. GE Sensing. Features. Applications
Applications Features The DigitalFlow GF868 flowmeter is a complete ultrasonic flow metering system for: Flare gas Track down or prevent losses from leakage with positive material identification Account
More informationE-Version SECTION 15318 - CHLORINATION SYSTEM PART 1 - GENERAL PART 2 - PRODUCT
SECTION 15318 - CHLORINATION SYSTEM PART 1 - GENERAL 1.1. SCOPE OF WORK A. Under this item the Contractor shall furnish and install a sodium hypochlorite solution metering system complete with all accessories
More informationwww.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
More informationUSER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat
Builder MODEL 1010 Series Non-Programmable Single Stage Heat/Cool Thermostat USER MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage
More informationElectro-Magnetic Flowmeters COPA-XT 2-Wire DT43
Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented
More informationVentostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:
GE Measurement & Control Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low
More informationHR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer
Smart Solutions for Drying Compressed Air Dual Tower Heat Reactivated Desiccant Air Dryer HR Heated HB Blower 800.943.794 www.engineeredairproducts.com Engineered Air Products Moisture in compressed air
More informationWaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB100-0100
WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.
More informationDORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS
Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short
More informationSpecifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]
Bulletin P-DM-1100 Series DM-1000 DigiMag Digital Differential Pressure Gage Specifications - Installation and Operating Instructions PRESSURE CONNECTIONS 21/64 [8.59] LONG Ø5 [127.00] 4-31/64 [113.89]
More information920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown
Self-Regulating 920 Series Dual-point heat-tracing control system Power-Limiting Mineral Insulated 920*E4FWL*SIS302*SS3102 shown Product overview The DigiTrace 920 is a compact, full-featured, microprocessor-based,
More informationHOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS
HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS PNEUMATIC SAFETY CONTROLS BASIC CONTROLS SC3000 - SELF CONTAINED 2 HAND CONTROL - STAND ALONE MODEL SC3300 - SELF CONTAINED 2 HAND CONTROL - PRESS READY
More informationBy Wayne Shannon Marketing Manager
A SAGE METERING White Paper [Type text] SAGE METERING 8 Harris Court, Building D1, Monterey, CA 93940 Telephone: (831) 242-2030 www.sagemetering.com By Wayne Shannon Marketing Manager July 8, 2015 Table
More informationT U R B I N E G A S M E T E R
TURBINE GAS METER TURBINE GAS METER CGT 1 2 3 4 5 6 7 Design and function page 2 General technical data page 3 Measurement outputs page 4 Dimensions and weights page 5 Performance page 7 Pressure loss
More informationElectromagnetic Flow Meter
Electromagnetic Flow Meter Description The EL 2200 series of electromagnetic sensors represent the state of the art for the accurate measurement for water cycle and process applications. Flow meters are
More informationHow To Size A Stenner Pump
Metering Pumps Manufactured Since 1957 PCM Series Pump Control Module INSTALLATION AND MAINTENANCE MANUAL Table of Contents WarrantyandServicePolicy...3 Safety Information...............................................
More informationBrooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters
Data Sheet Brooks Digital MFC's & MFM's Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters GENERAL FEATURES Wide FS flow range for measurement
More informationSUMMARY of PRODUCTS. HVAC Systems Control Airflow, Space, & Building Pressurization. Accurate airflow measurement for demanding applications
SUMMARY of PRODUCTS HVAC Systems Control Airflow, Space, & Building Pressurization Accurate airflow measurement for demanding applications Airflow Measuring Stations FAN-E AIRFLOW MEASURING STATION. The
More informationChapter2. Installation
Chapter2. Installation Power Supply Requirements The ULM-1000C operates from a DC supply of 20 30V and will typically draw less than 0.08A. All electronic products are susceptible to electrostatic shock,
More informationUTM10 Series Ultrasonic Transit-time Flowmeters
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationSeries DFMT Digital Paddlewheel Flowmeter
Series DFMT Digital Paddlewheel Flowmeter Bulletin F-DFMT Specifications - Installation Operating Instructions -/8 [00] -/ [8] -/8 [00] A The Series DFMT Digital Paddlewheel Flow Transmitter provides instantaneous
More informationIMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White
IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting
More informationKurz Instruments Inc. Document 360209-AV Document Title: MFTB Event Code Definitions. MFT B-Series Event Codes
MFT B-Series Event Codes The MFT B-series status information is contained in a 4-byte long word (32-bit) Event Code. This Event Code provides a bit-wise mapping of the status of the flow meter with each