Flat roof assembly system from Solarworld Design and installation

Size: px
Start display at page:

Download "Flat roof assembly system from Solarworld Design and installation"

Transcription

1 Flat roof assembly system from Solarworld Design and installation August 2009 SolarWorld. And EveryDay is a SunDay.

2 Proven quality simply clever Congratulations and thank you for choosing one of the high-quality Sunfix Assembly Systems from Solarworld AG. All Sunfix Assembly Systems are adapted individually to the situation on site-based on tested dimensions tables - and therefore offer the best possible and reliable used of the installation surface. Only the highest quality components are selected and used to ensure the trouble-free operation of your PV system. The directions below are simply intended to assist you in properly installing your Sunfix Assembly System and avoiding problems. Since individual circumstances may nonetheless vary, we advise you to seek expert assistance in adapting these recommendations to your particular roof situation. 2 Date: August 2009

3 Contents A Safety instructions Page 4 A 1 Hazard information Page 5 A 2 System design Page 6 A 3 Installation B Technical overview Page 7 B1 Construction of the system of assembly system Page 8 B2 Flat roof frame types Page 9 B3 External parameters Page 10 B4 Required ballast load C Assembly Page 11 C1 Bolting the frames Page 12 C2 Assembly of the profile surface Page 14 C3 Assembly of the frames Page 15 C 3.1 Assembly of the reinforcing strut (optional) Page 17 C4 Fixing the modules Page 17 C 4.1 Fixing the modules using frame type A (side-on module assembly) Page 19 C 4.2 Fixing the module using frame type B (end-on module assembly) Page 21 C5 Installation examples Page 25 C6 Fixing options Page 25 C 6.1 Hanger bolt fixing set Page 27 C 6.2 Trapezoidal roof fixing set Page 28 C 6.3 Standing seam clamp fixing set Page 29 C 6.4 Solar fastener fixing set Page 32 C7 Module connection Page 33 C8 Grounding Page 34 C9 Installation examples D Maintenance/Cleaning/ Page 35 Maintenance/Cleaning/Liability Liability 3

4 A Safety information X Please read all of the safety information and instructions carefully! X Non-adherence to the instructions below can cause electrocution, fire and/or serious injury. X Keep this manual safe for future reference! A1 Hazard information Risk of death by electric shock X Solar modules generate electricity as soon as they are exposed to light. The voltage of a single module is less than 50 V DC. When several modules are connected in series, the total voltage can be dangerously high and create a hazard. When the modules are connected in parallel, the currents are cumulative. Although touch protection is provided in the form of the fully insulated plug contacts, the following points must be observed when handling the solar modules to avoid the risk of fire, sparking and fatal electric shock: Do not install solar modules and cables with wet plugs and sockets! Perform any work on cables with the utmost care! High contact voltage can also occur in the inverter, even when it is isolated! 4 Risk of death by electric arc X Modules generate direct current (DC) when exposed to light. When breaking a connected string of modules (e.g. when disconnecting the DC line from the inverter under load), a lethally strong arc can occur: Never remove the solar generator from the inverter while it is still connected to the main grid. Ensure that the cable connections are in perfect working order (no cracking, no moisture, no contamination)!

5 A2 System design Generalsafetyinformation X Ensure that the substructure, support structure and other affected layers (such as an insulation layer) have adequate load capacity (based on dimensions, condition and suitable material properties). X When using ballast for position stability, make sure that the substructure has sufficient reserve load capacity. X Check whether protective mats are needed when securing the installation position with ballast. If this is the case, ensure that they are made of suitable materials. If you are uncertain as to the compatibility of the protective mat and the roof flashing materials, we would recommend fitting a separating mat layer. X The friction coefficient between the surface of the roof and the ballast element of the flat roof frames (e.g. concrete element) should be μ 0.6. X Make sure that the runoff of rainwater is not impeded. X Consider structural aspects, such as the possible formation of condensation caused by penetration through insulating layers. X In case of doubt, consult an expert (e.g. a structural engineer). X Protect cables installed out of doors from weathering, UV light and mechanical damage using suitable precautions (such as by using UV-resistant plastic pipes or metal conduits). X The distance between the module rows is calculated individually from the angle of inclination of the modules and the minimum angle of insolation at your location. Safety information for the edge areas X Air turbulence and therefore also significantly higher wind loads are to be expected around the corners and edge areas of roofs (cf. DIN and EC1). The installation of raised PV systems is not permitted in these areas. These areas (1.20 m from the long side of the building and 1.50 m from the narrow side of the building) must be kept clear at all times. X If the PV system is to be fixed onto the roof with ballasting (such as concrete slabs), then the outer elements should be weighted down with heavier loads (dark grey elements, see Fig.). Distance from edge to be maintained a = 1.20 m (long side of building) b = 1.50 m (narrow side of building) a b 5

6 A3 Installation Generalsafetyinformation X All work on the PV system (installation, commissioning, maintenance, repair) must exclusively be performed by adequately qualified and authorized persons. X Observe all local and national code requirements for the prevention of accidents during installation. X Secure persons working on the roof of a building higher than 3 m against falling with appropriate protective equipment. X Protect persons on the ground against falling objects with appropriate barriers. X Observe the safety instructions provided with all of the other system components. X Comply with all local codes and standards applicable in the relevant country for installation and commissioning. X The system connection to the public grid may only be performed by a qualified electrician. X Observe the applicable rules and standards for the respective country relating to installations on roofs. X When arranging the profiles: ensure that there is a gap of 5-7 mm between the end faces of the individual profiles. Special safety instructions X Observe the user information for modules and inverters, as well as the installation and wiring diagrams enclosed with the system supplied. X Ensure that all bolted connections are tightened properly. X Ensure that they are tightened to a torque of 20 Nm. 6

7 Distance of flat roof frame overhang Technical overview of assembly system B The Sunfix Assembly System for flat roofs is a support structure for the raised installation of PV modules. This means that it is possible to mount the PV modules in line with or towards the pitch of the roof. The roof pitch can be between 0 and 20. It is possible to mount the modules at right angles to the roof pitch up to a pitch of 5 with reinforcing elements, and modules fixed at right angles (flat roof frame type A) even up to 20. B1 System design Overview of system construction 1 Flat roof frame The flat roof frames with an angle of inclination of 15, 20 or 30 are manufactured from bolted, untreated aluminumprofiles. 2 Mountingprofiles The mounting profiles made of extruded untreated aluminum are bolted to the flat roof frame. 3 Modulefixing The modules are clamped to the supporting profiles. The clamping connection parts are made of V2A and aluminum. To prevent it from tipping and lifting, the flat roof frame must either be weighted down with ballast or joined in a force-locking way to the sub-structure. Ballast and any protective matting required is not included with the system. Please refer to section C4 for possible fixing elements. 7

8 B2 Flat roof frame types The modules can be mounted horizontally and vertically. Two different flat roof frames (type A and B) are needed for this. Both flat roof frames can be supplied with mounting angles of 15, 20 and 30. Flat roof frame type A (side on / horizontal installation of modules) Side view of flat roof frame type A Example of a system shown using flat roof frame type A Flat roof frame type B (end on / vertical installation of modules) α h b l Side view of flat roof frame type B Example of a system shown using flat roof frame type B Flat roof framedimensions Angle α Height h [mm] l [mm] Drill hole spacing b [mm] Type A Type B The maximum distance between the flat roof frames and the maximum overhang depends on the height of the building, the snow and wind load assumed for the region, the lie of the land and the height above sea level. It is therefore impossible to provide universal dimensions for this. Please refer to the system design for more accurate figures for your system. 8

9 B3 External parameters All of the external parameters to be observed are summarized in the following tables: Flat roof frame parameters Type A (side on / horizontal modules) Direction of the mounting with/towards the roof pitch at right angles to the roof pitch Wind load zone Depending on location/country Depending on location/country Snow load zone Depending on location/country Depending on location/country Height above sea level [m] Depending on location/country Depending on location/country Building height [m] Allowable roof pitch [ ] 0 to 20 0 to 20 Reinforcing struts Frame spacing [m] not required as required, depending on system design required for 5 roof pitch and above! 1 strut per module with reinforcement: e = 1.23 m or 0.95 m (depending on load)* otherwise as required, depending on system design *) The exact frame distance depends on the angle of the mounting and the tolerances of the drill holes, see Chapter C3.1 (Fitting the reinforcing strut). Non-standard solutions are available on request owing to the individual nature of the system design! Flat roof frame parameters Type B (end on / vertical modules) Direction of the mounting with/towards the roof pitch at right angles to the roof pitch Wind load zone Depending on location/country Depending on location/country Snow load zone Depending on location/country Depending on location/country Height above sea level [m] Depending on location/country Depending on location/country Building height [m] Allowable roof pitch [ ] 0 to 20 0 to 5 Reinforcing struts not required Frame spacing [m] as required, depending on system design Non-standard solutions are available on request owing to the individual nature of the system design! 9

10 B4 Required ballast load If the frames are not planned to be connected directly to the roof, then ballast must be provided, depending on the external parameters. This will ensure that the system is prevented from lifting, tipping or being displaced by wind loads. The expected wind loads must be calculated separately for each system, as they are dependent on the building type and its location. The following table shows ballast loads calculated for a building in wind load zone 1 in Germany with a module inclination of 30 (based on wind loads in accordance with the German standard DIN ). Building height [m] Wind load q [KN/m²] Minimum required ballast load with a module angle of 30 [kg] per m² module surface per SW module Edge area Innerarea Edge area Innerarea , , , Other figures will apply to differing mounting angles and wind load zones. The necessary loads are an integral part of every system design and are calculated separately for each system. The ballast required for the relevant system depends on the wind load assumptions applicable in the respective countryand thecorrespondingstandards. 10

11 Assembly C The Sunfix Assembly System for flat roofs is very simple to install. The order of steps described here is provided only by way of suggestion. C1 Assembly of the frames The frames consist of 3 aluminum angle profiles, which are bolted together. The dimensions of the aluminum profiles depend on the angle of the mounting (15, 20 or 30 ). If the mounting is at a right angle to the roof pitch, then reinforcing struts are needed for frames used on roof pitches of more than 5. These conduct any horizontal loads caused by snow and wind into the roof structure. The frames are delivered pre-assembled and need only to be assembled and bolted as shown in the following two figures (tightening torque: 20 Nm). Join and bolt the profiles together Flat roof frame as delivered Flat roof frame, ready assembled The three aluminum profiles are bolted in each corner with a V2A hexagonal bolt and nut with an M6 flange (type A) or an M8 flange (type B) (tightening torque: 20 Nm). The upper profile, to which the modules are fixed, has an overhang at its top end (cf. Fig.) Solar power module 2 Frame, bolted 3 Hexagonal bolt + nut (M6 for frame type A, M8 for frame type B) 4 Clamp 5 Roof construction 6 Reinforcing strut (optional only) 7 Supporting profile 5 11 Flat roof frame, fitted (frame type A is shown here)

12 C2 Assembly of the profile surface The mounting profiles are fitted in single or double layers under the flat roof frame. The structure depends on the orientation of the module and the roof construction. Two profile layers Example of a system with two profile layers under the flat roof frame One profile layer Example of a system with one layer of profiles under the flat roof frame There are different supporting profiles available depending on the substructure, the loads (snow, wind) and the type of mounting. All of the profiles can be individually combined with each other. 12

13 The profiles are factory-cut to the required length and therefore only have to be adjusted on site in special circumstances. Fix 60 Fix Trapez for riveting to trapezoidal metal sheeting Fix 43 Overview of profile types Fix 80 Distance of 5-7 mm Slip joints for Fix 43, Fix 60 and Fix 80 The individual lengths of profile are joined to each other with slip joints. One slip joint is needed per side with Fix 43, Fix 60 and Fix 80 support profile types, that is two slip joints per join. X Allow a spacing of 5-7 mm between the profiles. Two layers of frame can be joined together using clamps. 2 clamps are needed per intersection. Clamp connection Note on supporting profiles: For structural reasons, the support profiles should always be fitted end on (upright)! Profile fitted correctly Profile fitted incorrectly! 13

14 C3 Assembly of the frames Fix the frames with M8 T-head bolts with the flange nut on the surface of the profile. The distances between the frames are specified for structural reasons and can be found in the individual system design. A Detail A 14

15 C3.1 Assembly of the reinforcing strut (optional with frame type A) If the mounting is to be fitted at a right angle to the roof pitch and roof pitch is between 5 and 20, then the frame construction must be reinforced with reinforcing struts. The spacing between the frames is defined in this case as e = approx m (standard) or e = 0.95 m (heavy loads). One strut is needed per module. Bolt the struts with a stainless steel M6 flange hexagonal bolt and nut to the back of the frame (tightening torque: 20 Nm). This means that one end of the strut is at the top end of one frame and the other end is fixed to the bottom of the neighboring frame. We would recommend proceeding as follows: 1. Once the frames have been bolted, bolt the first frame onto the perpendicular running supporting profiles using 2 T-head bolts until it is hand tight. e = 1,23 m or 0,95 m 2. Then fix the second frame at a spacing of e = 1.23 m or e = 0.95 m until it is also hand tight. 3. Now join the two frames using the reinforcing struts. The frames can now be positioned exactly and all of the bolts can be tightened until firm (tightening torque: 20 Nm). The highest point of every reinforcing strut must point towards the ridge of the roof. Fit all of the other reinforcing struts needed in the same way. The number of struts is specified individually for every system and can be found in the design documents. The precise frame spacings depend on the angle of the mounting and the tolerances of the drill holes, hence the reason why the frames should be carefully aligned before the bolts are tightened. 15

16 Finished construction of a row of modules with reinforcing struts (example) Detail of the frame/reinforcing strut join 16

17 C4 Fixing the modules The modules are clamped onto the supporting profiles (also known as the clamping layer). There are two different flat roof frame types, as outlined in Chapter B2 - type A (fitted horizontally) and type B (fitted vertically). C4.1 Fixing modules with frame type A (modules fitted horizontally) 1. Fix the supporting profiles to the flat roof frame with M8 T-head bolts. A Important: Fit the supporting profiles on end (cf. Chapter C2)! Detail A A Flat roof frame B Mounting profile C M8 x 20 T-head bolt B C B A A 17

18 2. Now bolt the modules to the supporting profiles. B Detail B F D G D E D Clamping disc E M8 x 53 T-head bolt F Nut with ratchet toothing G Spacer 18

19 C4.2 Fixing modules with frame type B (modules fitted vertically) C 1. Fix the supporting profiles to the flat roof frame with M8 T-head bolts. Important: Fit the supporting profiles on end! Detail C A Flat roof frame B Mounting profile C M8 x 20 T-head bolt B C B A A 19

20 2. Now bolt the modules to the supporting profiles. D Detail D F D Clamping disc E M8 x 49 T-head bolt F Nut with ratchet toothing G Spacer D G E Generalinformation X Use a torque wrench to ensure that the bolt is tightened to the required contact pressure of 20 Nm. X Please note that it may not be possible to loosen the tightened stainless steel bolts without them being damaged beyond repair. X Align and position the modules precisely. X Tighten the bolts to the specified torque. X Carry out regular random checks on the specified torque of the bolts to ensure that the bolts or parts which they join are prevented from coming loose. We would recommend that a random check is carried out every two years. Fixing the modules using shear nuts Shear nuts can be provided for the solar modules as anti-theft protection. The hexagonal part of the nut shears off when the tightening torque has been reached. The bolt can therefore only be loosened with great difficulty. 20 Clamp after fixing the hexagonal drive has sheared off. The nut can no longer be loosened without the nut being damaged beyond repair. Clamp before fixing (Clamp FDR type A is shown)

21 C5 Installation examples A PV system is shown fitted to a corrugated fibre cement roof by way of example. Hanger bolts and an aluminum double flange are used to fix it to the substructure. The modules are mounted using flat roof frame type A (modules fitted on their side). 1. Preparatorywork We would recommend loosely pre-fitting the profile clamps and module fixings before commencing assembly of the modules. Profile clamp fixing Clamp FDR type A is shown 2. Define the position of the system and the fixing points Determine the position of the system on the roof and mark this. Note the relevant distances from the edge specified in the design documents. Position the support points (in this case hanger bolts/double flange) as shown on the installation plan provided. Position of the purlins 21

22 3. Fitting the fixing points Fit the hanger bolts and double flanges at the specified positions. X Refer here to Chapter C6 - Fixing options. 4. Fitting the lower layer of supporting profiles Align the vertical supporting profiles upwards and downwards and fix each one to the double flange with a T-head bolt. Always fit the supporting profiles on end (vertically) for structural reasons. If required, fit a connector between the profiles. 22

23 5. Fitting the upper layer of supporting profiles Mark the position of the horizontal supporting profiles as per the installation plan and fit the horizontal supporting profile using two profile clamps. Fit the supporting profiles on end. 6. Fitting the flat roof frames Now install the flat roof frames at the specified distance from each other (refer to the installation plan). 23

24 7. Fitting the upper layer of profiles (clamping later) Now the upper profiles can be bolted to the flat roof frames. Here profiles can be fitted with connectors (cf. Point 4). Fit the profiles on end! 8. Assembling the modules Now the long sides of the modules can be fixed to the supporting profiles using module clamps. Use a torque wrench when fitting the modules. Apply a torque of 20 Nm. Refer to the User Information on Modules supplied with the modules SW MA Flachdach EN 0030.indd :45:22 Uhr

25 C6 Fixing options C6.1 Hanger bolt fixing set Hanger bolts are ideal for fixing onto fiber cement corrugated sheets and trapezoidal roof panels with a timber substructure. Hanger bolt with flange Hanger bolt with double flange Hanger bolt 2 Flange nut 3 Flange or double flange 4 Flange nut 5 EPDM seal 6 Covering 7 Timber substructure 8 Supporting profile 9 T-head bolt 10 M8 flange nut 11 M10/M12 spacer min 90 mm max 212 mm 25

26 There are several possible attachment methods when using hanger bolts. A hanger bolt, with either a single flange or double flange, is used depending on the substructure and other requirements. Components X V2A hanger bolt with EPDM seal X Nuts X Spacers X Supporting profile fitting (flange or double flange) X M8 x 20 T-head screws with flange nuts Assembly 1. Mark the fixing point. To ensure that the roof can drain properly, alwaysarrange the fixing points in the high points of the roof. 2. Pre-drill through the roof covering (ds +2 mm, where ds is the nominal diameter of the bolt) and the substructure (0.7 x ds). 3. Screw in the hanger bolt sufficiently far: anchoring depth: 70 mm 4. Carefully press the EPDM seal onto the roof covering. 5. Clamp the fixing element between the two upper flange nuts (cf. Fig.). X Ensure that the connection is aligned as according to the assembly instructions. X The minimum dimensions of the purlins are w/h 70x70 (84/70) mm for a Ø10 (12) mm hanger bolt in accordance with DIN 1052, the German standard for timber construction. The height between the hanger bolts can be adjusted by means of metric thread. 26

27 C6.2 Trapezoidal roof fixing set The trapezoidal roof fixing set is ideal for fixing the modules on steel trapezoidal roofs with a thickness of 0.63mm. The supporting profile lies directly on the trapezoidal sheet metal, separated by an EPDM sandwich layer. It is fixed to the roof covering by means of press-plated blind rivets. The number of rivets is stipulated by the structural conditions when press-plate blind rivets are used. Please refer to your system design for the required number and position of the rivets. 1. Position the first rivet at the end of the profile above the fitting for the supporting profile. 2. Then arrange the rivets alternately above and below. The pre-drilling diameter for the rivets is 5.4 mm. 1 Press-plate blind rivets 2 EPDM sandwich layer 3 High section of corrugation

28 C6.3 Standing seam clamp fixing set The standing seam fixing set is ideal for fixing to metal roof covers with a simple or double standing seam. The standing seam clamp is available in aluminum, stainless steel and copper, depending on the material of the roof cover Supporting profile 2 Spacer 3 Flange nut 4 T-head bolt 5 Standing seam clamp 6 Standing seam roof 7 Substructure Components X Standing seam clamp X M8 x 20 T-head bolt X M8 Flange nut X Spacer The load capacity of each clamp is 80 kg at a tightening torque of 35 Nm. X Ensure on site that the load is transferred from the metal roof cover to the substructure. X Distribute the clamps over the roof so that as many seams as possible carry the load. Further clamps are available, for example for Kalzip and RibRoof roofs. 28

29 C6.4 Solar fastener fixing set The solar fastener is a fixing for mounting PV systems onto sandwich roofs. It is available in different versions and is bolted into the support substructure of the roof (timber or steel). Greater stability and tightness of the construction is provided by the calotte included with the set. The solar fastener can also be fixed into trapezoidal and corrugated roofs. Callot steel or timber substructure Installed on a sandwich roof Please note the following points when fitting the solar fastener: X Always anchor the solar fastener to the substructure. X Ensure that the connection point is in the raised point of the roof element (raised corrugation). X Steel and timber purlins can be used as the substructure. X Observe the general technical approval Z

30 We recommend proceeding as follows when fitting the solar fastener: 1. Select the pre-drill diameter from the table. 2. Select the drill length and drill hole depth according to the length of the bolt. 3. Make the drill hole. X The depth of the drill hole must be at least 10 mm larger than the penetration depth of the bolt. X The drill hole must be at right angles to the surface. 4. Remove any swarf from the surface. 5. Screw in the solar fastener using a power screwdriver and a suitable bit (cf. Table) at a speed of n 100 rpm. X The sealing disc should not be compressed by more than 25%. Solar fastener Designation Substructure [mm] Predrilling-Ø [mm] Actuation on setscrew Screw length/ screw-in depth [mm] JZ3-SB-8.0xL-E16/8 + storm washer JZ3-SB-8.0xL-FZD 1.5 < < < mm SW 5 Screw length: thickness of the sandwich panel or corrugation height + 20 mm JA3-SB-6.5xL-E16 + storm washer JA3-SB-8.0xL-E16/8 + storm washer JA3-SB-6.5xL-FZD Wood 4.5 SW 4 Embedment in wood: SW SW JA3-SB-8.0xL-FZD Wood 5.5 SW JA3-SB-10.0xL-FZD 7.0 SW

31 Additional measures with transverse loading of the solar fastener If the solar fasteners will be subjected to perpendicular forces to the profile plates, extra corrugated fasteners must be used to attach the profile plates to the substructure. Install these fasteners in the immediately adjacent troughs to the solar fastener at the same height. If there are perpendicular forces along the profile plates, joints that are farther away may need additional corrugated fasteners to transfer the load. Ensure that the perpendicular forces are completely transferred from the solar fasteners to the substructure. too little correct Solar fastener under transverse loading too tight The following Ejot bolts can be used: Timber substructures Bolts: Length L: Pre-drilling diameter: JT xL with Ø 22 mm sealing disc Thickness of the sandwich profile in the trough + 50 mm without pre-drilling Steelsubstructure Bolts: Length L: Pre-drilling diameter: JZ xL with Ø 22 mm sealing disc Thickness of the sandwich profile in the trough + 20 mm dependent on the thickness of the steel element: Thickness of the steel element [mm] Pre-drilling diameter [mm] 2.0 d d d

32 C7 Module connection String 1 String 2 Attention: The series connection of modules may result in potentially fatal voltages! 3 1. Wire the modules using the wiring diagram. X Adhere to the provisions of the wiring diagram (string distribution, electrical switches, group cables). Incorrect wiring may cause damage to the inverter and/or the modules. X In order to keep inductive coupling as low as possible in the event of a lightning strike, the supply and return cables (+/-) of the string should be laid as closely to each other as possible (avoid loops). X Do not allow the minimum bending radius of the cables to be below 5x the cable diameter. X Do not lay or install any modules at a temperature of less than -5 C. 2 X Keep plugs and sockets dry during installation. 2. Install the group cable. 3. Attach the cable to the supporting profile using the UV-resistantcable ties Install and wire the subsequent module rows. Observe the polarity when doing so. Testing 1. Check the correct generator connection of the multi-string solar generator by measuring the open circuit voltages of the individual strings. 2. Compare the measured values to the specification. Deviating values indicate wiring errors! X Never connect the inverter for test purposes. 1 Mains power 2 Inverter 3 Solar power generator X The solar power system may only be connected to the public grid and isolated by an authorized electrician. X The technical instructions enclosed with the unit must be strictly adhered to for the installation, electrical connection and operation of the inverter. 32

33 C8 Grounding The installation company is responsible for ensuring the professional grounding of the system. No external lightning protection A ground is recommended for the PV module frame and mounting frame. Connect all electrical conducting parts to each other with measures suited to this purpose and connect them to the primary earth connector (PAS) with at least 6mm² (copper). External lightning protection in place The PV module frame and mounting frame must be incorporated in the scheme to protect against a direct lightning hit. Consider obtaining advice from a lightning protection expert. 33

34 C9 Installation examples Example1 Secure the system from tipping and lifting with ballast Roof skin 2 Protective mat 3 Ballast (provided by others) 4 Flat roof frame, bolted 5 Mounting profile 6 Solar power module 7 Existing flat roof (e.g. steel concrete roof with insulation) The system design also provides information on the required loads/ballast (Pos. 3) for the flat roof frame. This must be provided and installed on site (e.g. concrete slabs). The ballast loads needed are listed by way of example in Chapter B4 of this installation manual. These depend on the height of the building, the mounting angle and the wind loads and are calculated individually for each system. Example 2 Fixing onto a standing seam roof Standing seam roof 2 Standing seam clamp 3 Flat roof frame 4 Mounting profile 5 Solar power module

35 Maintenance/Cleaning/Liability D Maintenance andcleaning X It is not generally necessary to clean the modules where there is a roof pitch of more than 15 (rainfall will have a self-cleaning effect). X In the event of heavy contamination (reduced performance), we would recommend cleaning the modules with plenty of water (from a hose) without cleaning agents and using a gentle cleaning tool (sponge). Dirt must never be scraped or rubbed away when the modules are dry as this may cause micro-scratches, which can have an adverse effect on the performance of the modules. X The generator field should be inspected at regular intervals (at least once every two years) to ensure that it has a flawless condition (visual inspection, checking of joins). Liability X Since observance of these installation instructions and the conditions and methods of installation, operation, use and maintenance of the Sunfix Assembly System cannot be checked or monitored by SolarWorld AG, SolarWorld AG accepts no liability for damage arising through improper use or incorrect installation, operation, use or maintenance. Moreover, SolarWorld assumes no liability unless SolarWorld, its representatives or vicarious agents are accused of gross negligence or intent. The previous restrictions do not apply to damages relating to fatal injury or physical injury or inhury to health, as well as in cases applicable to other laws,such as the liability for assumption of guarantee, liability according to the German Product Liability Act (Produkthaftungsgesetz) or in the case of infringements of important contractual obligations (cardinal obligations). X Regardless of the previously described limitations of liability, SolarWorld assumes no liability for infringements of patent law or infringements of third party rights arising from the use of the modules and the assembly system, as is present under the regulations previously described. X The text and figures in this manual comply with the state of technology at the time of printing. Subject to change. 35

36 Production and distribution sites of the SolarWorld Group KA Production Deutsche Solar/Freiberg, Germany Deutsche Cell/Freiberg, Germany Solar Factory/Freiberg, Germany Sunicon/Freiberg, Germany SolarWorld Innovations/Freiberg, Germany SolarWorld Industries America/Camarillo, USA SolarWorld Industries America/Vancouver, USA SolarWorld Industries America/Hillsboro, USA SolarWorld Korea, Korea Distribution SolarWorld Head Office/Bonn, Germany SolarWorld Ibťrica/Madrid, Spain SolarWorld Africa/Cape Town, South Africa SolarWorld Asia Pacific/Singapore, Singapore SolarWorld California/Camarillo, USA SolarWorld AG Martin-Luther-King-Str Bonn Germany SolarWorld Ibérica, S.L. C/La Granja 15, Bloque B-1º B Alcobendas, Madrid Spain SolarWorld California LLC 4650 Adohr Lane Camarillo, CA USA SolarWorld Africa Pty. Ltd. 20th Floor 1 Thibault Square Cape Town, 8001 South Africa SolarWorld Asia Pacific Pte. Ltd. 72 Bendemeer Road #07-01, Luzerne Singapore Singapore SolarWorld AG Martin-Luther-King-Str Bonn Germany Telephone: Fax: service@solarworld.de SolarWorld. And EveryDay is a SunDay.

PITCHED ROOF STRUCTURES

PITCHED ROOF STRUCTURES PITCHED ROOF STRUCTURES for framed and frameless photovoltaic modules Needed tools and materials: cordless screwdriver 10mm and 13mm spanners 5mm Allen key bolts, screws and tools for fixing the system

More information

HORIZONTAL INSTALLATION

HORIZONTAL INSTALLATION THERMO/SOLAR Žiar s.r.o. MANUAL FOR INSTALLATION PV SUPPORTING FRAMES HORIZONTAL INSTALLATION Technical alternation reserved A1410 1 12/2014 CONTENT ORD.NO. PAGE Mounting information 3 Mounting, flat roof

More information

Phoenix Solar AG. Phoenix TectoSun 3 Installation instructions

Phoenix Solar AG. Phoenix TectoSun 3 Installation instructions AG Phoenix TectoSun 3 Installation instructions 2 THE TECTOSUN 3 MOUNTING SYSTEM FROM PHOENIX SOLAR THE ADVANTAGES AT A GLANCE Tested by TÜV, RAL seal of uality for all components Quick and easy installation

More information

AA Solar and Sun Power Plus

AA Solar and Sun Power Plus AA Solar and Sun Power Plus www.aasolar.co.nz www.sunpowerplus.co.nz -1- Contents Chapter Title Page 1 General information 3 2 Safety and Installer Responsibilities 4 3 Technical Specifications 5 4 Tools

More information

6720616592.00-1.SD. Flat roof. Rack Mounting. Installation instructions 6 720 647 036 (2010/11) AU

6720616592.00-1.SD. Flat roof. Rack Mounting. Installation instructions 6 720 647 036 (2010/11) AU 6720616592.00-1.SD Flat roof Rack Mounting AU Installation instructions 2 Contents AU Contents 1 Key to symbols and safety instructions....... 3 1.1 Explanation of symbols................ 3 1.2 Safety

More information

0845 0098 980 www.nicholsonsts.com

0845 0098 980 www.nicholsonsts.com 0845 0098 980 www.nicholsonsts.com ROOFTRAK The IFP is revolutionising the way we fix things to roofs. Technical Director of a leading UK roofing system manufacturer The ROOFTRAK-IFP A revolutionary solution

More information

PV Mounting System For Crystalline Solar Module THE POWER OF ASTRONERGY

PV Mounting System For Crystalline Solar Module THE POWER OF ASTRONERGY PV Mounting System For Crystalline Solar Module THE POWER OF ASTRONERGY Tile on-roof PV Mounting System Installation on tiles roof. Various quick roof hooks with different strength and structure are available.

More information

UBBINK SOLAR IN-ROOF SYSTEM

UBBINK SOLAR IN-ROOF SYSTEM UBBINK SOLAR IN-ROOF SYSTEM The integrated solar mounting system Installation guide UBBINK SOLAR IN-ROOF SYSTEM Table of contents Solar In-Roof System introduction System components Installation guide

More information

Installation manual ValkPitched - Insert

Installation manual ValkPitched - Insert Van der Valk Solar Systems TRCKING ND FIXED SOLR MOUNTING SYSTEMS Installation manual ValkPitched - Insert Version 10 EN General user instructions Solar mounting systems Congratulations on buying a Van

More information

ATS Overhead Table Shelf System INSTRUCTION MANUAL

ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship

More information

00MK-MA0190-EN00. Mounting System ASSEMBLY INSTRUCTIONS. Universal Light system with locking brackets, for sloped roof

00MK-MA0190-EN00. Mounting System ASSEMBLY INSTRUCTIONS. Universal Light system with locking brackets, for sloped roof 00MK-MA0190-EN00 Mounting System ASSEMBLY INSTRUCTIONS Universal Light system with locking brackets, for sloped roof Rev.02 November 2014 Table of contents General instructions 2 General safety instructions

More information

Saferand easierinstallation

Saferand easierinstallation EN 85-07 Saferand easierinstallation IföSigninstallationsystem andifösignbuilt-incistern www.ifosanitar.com/sign Aneffectivesolution withmanyadvantages. Ifö Sign installation system makes life a little

More information

Installation Guide of Sunrise Solartech PV Modules. Term 2013. Contents. Purpose of this guide. General. Safety precaution for installing a solar

Installation Guide of Sunrise Solartech PV Modules. Term 2013. Contents. Purpose of this guide. General. Safety precaution for installing a solar Installation Guide of Sunrise Solartech PV Modules Term 2013 Contents Purpose of this guide General Safety precaution for installing a solar Photovoltaic system Product Identification Mechanical Installation

More information

Installation manual Pitched Roof Clamp System

Installation manual Pitched Roof Clamp System Van der Valk Solar Systems TRACKNG AND FXED SOLAR MOUNTNG SYSTEMS nstallation manual Pitched Roof Clamp System Version 11 EN General user instructions Solar mounting systems Congratulations on buying a

More information

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors Installation Manual Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors SW602206 Rev B Table of Contents Chapter 1: Safety Warning... 3 Chapter 2: Kit Contents... 4 Included in Kit...

More information

Installation manual ValkPitched - Clamp

Installation manual ValkPitched - Clamp Van der Valk Solar Systems TRCKING ND FIXED SOLR MOUNTING SYSTEMS Installation manual ValkPitched - Clamp Version 16 EN General user instructions Solar mounting systems Congratulations on buying a Van

More information

Solar Mounting System

Solar Mounting System Xiamen Antai New Energy Tech.Co., Ltd Installation Manual Antai Rail Solar Mounting System (Flat Roof Solution) Version 1.1 Office Add: 508#, North Tower, Guangxia Building Huli Torch Hi-tech Zone, Xiamen,

More information

BUILD A CARPORT. 2 - Planning the carport. 3 - Designing the carport

BUILD A CARPORT. 2 - Planning the carport. 3 - Designing the carport BUILD A CARPORT You only need basic DIY and woodworking skills to build a carport. The most important part of the job is setting the supporting posts truly vertical - a job for which another pair of hands

More information

RAIL FREE SOLAR ROOF MOUNT

RAIL FREE SOLAR ROOF MOUNT RAIL FREE SOLAR ROOF MOUNT Utilizes EcoFasten Solar s patented technology Rock-it system Designed with the installer in mind. EcoFasten Solar specializes in solar roof attachments that are the easiest

More information

March 14, 2007. Installation of Bay, Bow and Garden Windows

March 14, 2007. Installation of Bay, Bow and Garden Windows March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed

More information

Washer, Electrical Equipment Bond WEEB

Washer, Electrical Equipment Bond WEEB Washer, Electrical Equipment Bond WEEB INSTALLATION INSTRUCTIONS For IronRidge Light & Standard Series Rails Only Please read carefully before installing. Burndy recommends that the sufficient details

More information

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table

More information

Guidelines for Earthquake Bracing of Residential Water Heaters

Guidelines for Earthquake Bracing of Residential Water Heaters Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)

More information

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE 86 :: Certificate in Construction Supervision (CIVIL) 12 ROOF 12.1 INTRODUCTION The structure provided to cover the house surface (floor) is known as roof. For different situation and requirement, it is

More information

GENERAL INSTALLATION MANUAL FOR EGING PV MODULES

GENERAL INSTALLATION MANUAL FOR EGING PV MODULES GENERAL INSTALLATION MANUAL FOR EGING PV MODULES PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLING OR USING THE MODULES. PLEASE PASS ALONG THE ATTACHED USER MANUAL TO YOUR CUSTOMER. 1. INTRODUCTION This

More information

39HQ Airovision Air Handling Units

39HQ Airovision Air Handling Units 39HQ Airovision Air Handling Units Mounting instructions CONTENTS 1 - TRANSPORT AND LIFTING INSTRUCTIONS... 3 1.1 - General... 3 1.2 - Transport and storage... 3 1.3 - Roof edge protection during transport

More information

Operating Instructions Drill rig DRU160

Operating Instructions Drill rig DRU160 Operating Instructions Drill rig DRU160 Index 000 / 001 Original operating instructions 10988825 en / 20.10.2009 Congratulations! With a Hydrostress unit from TYROLIT you have chosen a tried and tested

More information

Installation Instructions For Slider Casement Air Conditioners

Installation Instructions For Slider Casement Air Conditioners Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05 TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation

More information

2100 AD 015 0009 Mirror Elevator Ball Nut Replacement Procedure

2100 AD 015 0009 Mirror Elevator Ball Nut Replacement Procedure 2100 AD 015 0009 Mirror Elevator Ball Nut Replacement Procedure Derek Guenther 1/28/2015 Rev. Purpose The purpose of this document is to describe the procedure necessary to replace one of the ball nuts

More information

ASSEMBLY INSTRUCTIONS Residential Roof solutions

ASSEMBLY INSTRUCTIONS Residential Roof solutions ASSEMBLY INSTRUCTIONS Residential Roof solutions CROSSRAIL System USA Table of contents TABLE OF CONTENTS THE COMPANY SAFETY REGULATIONS MATERIALS REQUIRED TOOLS REQUIRED ASSEMBLY TERMS AND CONDITIONS

More information

Permanent Stainless Steel Anchorage Point for Concrete, Solid Masonry and Steel Constructions

Permanent Stainless Steel Anchorage Point for Concrete, Solid Masonry and Steel Constructions ABS-Lock X / X - SR Permanent Stainless Steel Anchorage Point for Concrete, Solid Masonry and Steel Constructions The ABS-Lock X system was developed to provide both a secure single anchorage point for

More information

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions Trillium 40 Axis Spring Tensioner Wire Replacement Instructions 1 Overview The objective is to replace the broken axis spring tensioner wire. This requires the following tasks: 1. Remove the seismometer

More information

How To Mount An Ecosa Series Solar Panel

How To Mount An Ecosa Series Solar Panel (including PanelClaw ) This Guide is valid in North America only (ETL listed; conforms to UL Standard 1703) PanelClaw is a registered trademark of PanelClaw, Inc. SM-0050revA ELECTRICAL EQUIPMENT CHECK

More information

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: 1996. No.: SE-...

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: 1996. No.: SE-... Installation guide for the SafeLine type anchorage device Tested in compliance with EN 795: 1996 No.: SE-... Version: 09.10.2008 SE 67 Subject to technical alterations! Contents 1. General information

More information

RAY-MAX Integrated Solar Power Strip

RAY-MAX Integrated Solar Power Strip RAY-MAX Integrated Solar Power Strip 600008, 600009, 600010, 600208, 600209, 600210 Owner s Manual NEXTRONEX, INC. Revision Date: 10/27/14 Contents 1. Safety Instructions... 3 2. General Equipment Warnings...

More information

Cable Support System Guide for Andersen Bow, Bay, and Box Projecting Window Units

Cable Support System Guide for Andersen Bow, Bay, and Box Projecting Window Units for Andersen Bow, Bay, and Box Projecting Window Units Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance are essential if the

More information

DEHN + SÖHNE. DEHNconductor System No Problems with Proximities

DEHN + SÖHNE. DEHNconductor System No Problems with Proximities DEHN + SÖHNE DEHNconductor System No Problems with Proximities DEHNconductor System - New Possibilities for controling Proximities. For preventing dangerous flashovers among parts of external lightning

More information

YINGLI SOLAR PV MODULES Installation and User Manual

YINGLI SOLAR PV MODULES Installation and User Manual YINGLI SOLAR PV MODULES Installation and User Manual Revision Date December 24, 2011 Applicable for IEC certified products This manual applies to photovoltaic modules ( PV modules, also commonly known

More information

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium

More information

Installation Instructions

Installation Instructions READ BEFORE INSTALLING UNIT For Slider Casement Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal) Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal) IMPORTANT: It is imperative that the user read these warnings and use of the assembly instructions

More information

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide circuit. Reverse connection will damage the module and may result in fire. CAUTIONS Solar electric modules produce DC electricity

More information

INFRARED QUARTZ WALL HEATER

INFRARED QUARTZ WALL HEATER INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this

More information

ES-A Series Photovoltaic Panels

ES-A Series Photovoltaic Panels Guide This Guide is valid in North America only (ETL listed; conforms to UL Standard 1703) ELECTRICAL EQUIPMENT CHECK WITH YOUR INSTALLER Evergreen Solar ES-A Series photovoltaic (PV, solar electric) panels

More information

Solar Kit. Complete solution to optimize your photovoltaic system

Solar Kit. Complete solution to optimize your photovoltaic system Solar Kit Complete solution to optimize your photovoltaic system April 2012 Mounting and selection quick guide On Grid Solar Kit rooftop installation INSTALLATION WITH OVERLAID SUB-STRUCTURE (A.1, A.2)

More information

Guidelines for Earthquake Bracing Residential Water Heaters

Guidelines for Earthquake Bracing Residential Water Heaters Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the

More information

INSTRUCTIONS: LocknCharge Laptop Carts

INSTRUCTIONS: LocknCharge Laptop Carts INSTRUCTIONS: LocknCharge Laptop Carts www.lockncharge.com Extra Tools required: Hammer, Philips head screwdriver, medium adjustable spanner. (Allen key supplied) (Panel colours for illustration purposes

More information

PANELIZED HOME INSTALLATION GUIDELINE

PANELIZED HOME INSTALLATION GUIDELINE PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance 02/15 Labko GRP cesspools Instructions for installation, operation and maintenance Reliable solutions Wastewater treatment systems Contents 1 LABKO CESSPOOLS... 3 1.1 GENERAL... 3 1.2 IMPORTANT TO KNOW

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION TECHNICAL INFORMATION Models No. 2012NB Description 304mm (12") Automatic Thickness Planer CONCEPTION AND MAIN APPLICATIONS * Compact and light weight (27 Kg./59 lbs) automatic thickness planer for easier

More information

Residential Roofing Guide

Residential Roofing Guide Residential Roofing Guide TABLE OF CONTENTS Building Detail and Accessories...... 1 Panel Introduction and Handling...... 2 Cutting and Trimming.... 3 Roof Preparation..... 3 Roof Slope..... 3 Re-roofing...

More information

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 info@cardok.com

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 info@cardok.com CARDOK CARLIFT Fast access to underground garages Fast, Silent, Discreet, Design, High-Tech Installation to replace an access ramp on private property Dimensions: (Built to measure, all dimensions can

More information

Technical Information

Technical Information Technical Information This section of the catalogue provides technical information that will help specify, install and maintain Surelock McGill devices and components. The topics are listed below: Blast

More information

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally

More information

Technical handbook Panel Anchoring System

Technical handbook Panel Anchoring System 1 Basic principles of sandwich panels 3 Design conditions 4 Basic placement of anchors and pins 9 Large elements (muliple rows) 10 Small elements (two rows) 10 Turned elements 10 Slender elements 10 Cantilevering

More information

Packaged Terminal Air Conditioner Wall Sleeve Installation

Packaged Terminal Air Conditioner Wall Sleeve Installation Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation

More information

METHOD STATEMENT INSTALLATION OF INSULATING FLANGE KITS

METHOD STATEMENT INSTALLATION OF INSULATING FLANGE KITS METHOD STATEMENT INSTALLATION OF INSULATING FLANGE KITS Revision Date Prepared By Approved By Method Statement IF Kits BAC Corrosion Control Limited Stafford Park 11 Telford TF3 3AY Tel: 01952 290321 Fax:

More information

Machine devices, jig devices

Machine devices, jig devices Machine devices, jig devices 853 K0697 Rolled thread studs DIN 6379 Material: Tempered steel. KIPP Rolled thread studs DIN 6379 Order No. D L B1 B2 Approx. weight g Surface finish: Thread rolled. Class

More information

Solar Panel Installations

Solar Panel Installations Solar Panel Installations Page 1 of 6 SINGLE-FAMILY RESIDENTIAL CHECKLIST City of Hayward Development Services Department Revised: 7-09-15 PERMIT REQUIREMENTS Permits are required for all solar panel installations.

More information

Installation instructions of the MIDI-Heki roof light with operating bar, with crank or electrical version

Installation instructions of the MIDI-Heki roof light with operating bar, with crank or electrical version Installation instructions of the MIDI-Heki roof light with operating bar, with crank or electrical version with operating bar with crank electrical version 1. Prerequisite for a correct installation of

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

Chapter 3 Pre-Installation, Foundations and Piers

Chapter 3 Pre-Installation, Foundations and Piers Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory

More information

2.4M SERIES 1241 ANTENNA

2.4M SERIES 1241 ANTENNA 4096-859 Revision A August 7, 2012 2.4M SERIES 1241 ANTENNA GENERAL DYNAMICS SATCOM Technologies 1500 Prodelin Drive Newton NC 28658USA Phone 828-464-4141 www.gdsatcom.com Prodelin Corporation Page 1 8/17/2012

More information

Front axle components, overview

Front axle components, overview just a test. Front axle components, overview 40-1 General Information Load bearing components and parts of the suspension must not be welded or straightened. Vehicles without drive axle must not be moved,

More information

Rooflight INSTALLATION INSTRUCTIONS

Rooflight INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Rooflight These instructions should be used for: Installing Permanent Trickle Ventilation: Constructing & Waterproofing a Timber Upstand Curb: Installing & Waterproofing Proprietary

More information

Policy on Water Heater Installations Policy No. UPC 510-1-94 Effective: September 1, 1995 Revised: February 10, 1996

Policy on Water Heater Installations Policy No. UPC 510-1-94 Effective: September 1, 1995 Revised: February 10, 1996 CITY OF SAN JOSE BUILDING DIVISION POLICY Policy on Water Heater Installations Policy No. UPC 510-1-94 Effective: September 1, 1995 Revised: February 10, 1996 All new and replacement water heaters installed

More information

XL PREMIUM OIL COOLER KIT

XL PREMIUM OIL COOLER KIT -J05 REV. 0-0-0 XL PREMIUM OIL COOLER KIT GENERAL Kit Number 0008 Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com (English

More information

S OUNTING INSTRUCTION M M o u n t i n g k i t 2 &

S OUNTING INSTRUCTION M M o u n t i n g k i t 2 & M O U N T I N G I N S T R U C T I O N S instructions This document is protected by copyright. The SICK AG company retains this right. Reproducing this document in whole or part is only permissible within

More information

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection w Technical Product Information Precision Miniature Load Cell with Overload Protection 1. Introduction The load cells in the model 8431 and 8432 series are primarily designed for the measurement of force

More information

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A Technical Data Manual Model Nos. and pricing: see Price List Vacuum tube collector based on the heat pipe principle For the utilisation of solar energy VITOSOL r 200-T SP2A Product may not be exactly as

More information

Installing the Sno-free Standing Seam System for Metal Roofs

Installing the Sno-free Standing Seam System for Metal Roofs Installing the Sno-free Standing Seam System for Metal Roofs SFP SSP CLIP SSP STANDING SEAM SFP EXTRUSION SFP RAMP PANEL Step # 1 Mark the location and Install Extrusion Mark the area on the roof to receive

More information

Installation Instructions

Installation Instructions READ BEFORE INSTALLING UNIT For Through-the-Wall Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:

More information

CSUN Crystalline Silicon PV Module Products Installation Manual (IEC Version)

CSUN Crystalline Silicon PV Module Products Installation Manual (IEC Version) CSUN Crystalline Silicon PV Module Products Installation Manual (IEC Version) ADD.:No.123, Focheng West Road, Jiangning Development Zone, Nanjing, China Code: 211100 TEL. : +86-25-52766666-6530/6728 FAX:

More information

Operation manual. drill rig KERN-DEUDIAM KBS-Series K100

Operation manual. drill rig KERN-DEUDIAM KBS-Series K100 Operation manual drill rig KERN-DEUDIAM KBS-Series K100 Please read these instructions carefully before starting up the machine to avoid accidents and work interruption. 1. Table of contents 1. Table of

More information

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage: Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial

More information

RAUFOSS EXPLOSIVE COMPRESSION FITTINGS

RAUFOSS EXPLOSIVE COMPRESSION FITTINGS INSTRUCTION MANUAL FOR RAUFOSS EXPLOSIVE COMPRESSION FITTINGS Box 7 2831 Raufoss Norway Tlf.: +47 61 15 17 87 Fax: +47 61 15 25 56 25 January 2013, rev 2 Available on www.vpmetall.no Page 1 CONTENTS GENERAL

More information

M113 VEHICLE FAMILY RUBBER TRACK INSTALLATION INSTRUCTIONS SOUCY TRACK SYSTEM 04-M113-1ENS (SPLIT IDLER) Litho d in Canada 1 04-M113-1ENS

M113 VEHICLE FAMILY RUBBER TRACK INSTALLATION INSTRUCTIONS SOUCY TRACK SYSTEM 04-M113-1ENS (SPLIT IDLER) Litho d in Canada 1 04-M113-1ENS M113 VEHICLE FAMILY RUBBER TRACK INSTALLATION INSTRUCTIONS (SPLIT IDLER) 1 # TABLE OF CONTENTS List of parts and tools................................................3 Installation of complete kit...................................................5

More information

Installation instruction do88 Intercooler for Volvo S40 / V50 / C30

Installation instruction do88 Intercooler for Volvo S40 / V50 / C30 Installation instruction do88 Intercooler for Volvo S40 / V50 / C30 This instruction shows how to replace the OEM intercooler with our performance intercooler. 2. 3. 1. 4. 5. Part number: ICM-170 6. At

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

INSTALLATION OF A BAY WINDOW

INSTALLATION OF A BAY WINDOW INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening

More information

INSTALLATION. General. Important Note. Design. Transport

INSTALLATION. General. Important Note. Design. Transport General The roof trusses you are about to install have been manufactured to precise engineering standards. To ensure that the trusses perform as designed, it is essential that they be handled, erected

More information

FTC 2015-2016 DIY Mountain Build Guide

FTC 2015-2016 DIY Mountain Build Guide FTC 2015-2016 DIY Mountain Build Guide Assembly Instructions Check out the DIY2015-2016 Prints and BoM for individual part details. Release 1.0 9/10/15 Page 1 This guide and Bill of Materials are for constructing

More information

Roof Curbs, Extensions and Equipment Supports

Roof Curbs, Extensions and Equipment Supports Roof s, Extensions and Equipment Supports December 2012 Roof Page s, Header Extensions and Equipment Supports Table of Contents Model GPI Standard and Optional Construction Features... 3 Model Number Code....

More information

Installation Instructions

Installation Instructions Installation Instructions READ BEFORE INSTALLING UNIT For Low Profile Window Air Conditioner INSTALLATION WARNINGS AND CAUTION Carefully read the installation manual before beginning. Follow each step

More information

Installation manual Solar Tracker

Installation manual Solar Tracker Van der Valk Solar Systems TRACKNG AND FXED SOLAR MOUNTNG SYSTEMS nstallation manual Solar Tracker Version 07 EN General user instructions Solar mounting systems Congratulations on buying a Van der Valk

More information

Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide

Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide Lunette 2 Series Curved Fixed Frame Projection Screen User s Guide Important Safety and Warning Precautions Please follow these instructions carefully to ensure proper maintenance and safety with your

More information

Installation Instructions for Standing Seam Profiles INTERFALZ ALUDECK. flexible building. sustainable thinking.

Installation Instructions for Standing Seam Profiles INTERFALZ ALUDECK. flexible building. sustainable thinking. Installation Instructions for Standing Seam Profiles INTERFALZ ALUDECK flexible building. sustainable thinking. INSTALLATION INSTRUCTIONS Table of contents General information 4 1.9. Flashings 38 1.9.1.

More information

AerAtron. Ceiling fans

AerAtron. Ceiling fans AerAtron Ceiling fans User Manual & Technical Specifications Models: e502 & e503 Electricians PLEASE FOLLOW THESES INSTRUCTIONS CAREFULLY & PAY SPECIAL ATTENTION TO THE NOTES NOTES WILL ASSIST WITH AN

More information

ADM1TE 5/30A DIN rail single phase two wire energy meter

ADM1TE 5/30A DIN rail single phase two wire energy meter ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.

More information

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED. CAST IRON THE BASICS 1. DO NOT LIFT ON YOUR OWN. 2. ONLY LIFT THE RADIATOR VERTICALLY. 3. DO NOT LIFT MORE THAN 8/10 SECTIONS AT ANY ONE TIME. 4. POSITION THE RADIATOR BEFORE FINAL ASSEMBLY. 5. THIS PRODUCT

More information

Installation. Smart-UPS VT MGE Galaxy 3500. Maintenance Bypass Panel. 10-40 kva 400 V

Installation. Smart-UPS VT MGE Galaxy 3500. Maintenance Bypass Panel. 10-40 kva 400 V Installation Smart-UPS VT MGE Galaxy 3500 Maintenance Bypass Panel 10-40 kva 400 V Contents Safety.................................................. 1 Save these instructions...................................

More information

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

Mounting Instructions. Torque Transducer. A0329 3.2 en

Mounting Instructions. Torque Transducer. A0329 3.2 en Mounting Instructions Torque Transducer T5 T5 Contents 3 Page Safety instructions.............................................. 4 1 Measuring characteristics..................................... 7 2 Mounting.....................................................

More information

Elektromotoren und Gerätebau Barleben GmbH

Elektromotoren und Gerätebau Barleben GmbH Elektromotoren und Gerätebau Barleben GmbH OPERATING INSTRUCTIONS Transformer Protection Relay (Buchholz principle) Elektromotoren und Gerätebau Barleben GmbH Table of contents Page 1 Safety instructions

More information

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings

More information

INSTALLATION INSTRUCTIONS: Viewline 52 mm

INSTALLATION INSTRUCTIONS: Viewline 52 mm -5 Safety information The product was developed, manufactured and inspected according to the basic safety requirements of EC Guidelines and state-of-the-art technology. The instrument is designed for use

More information

SMD Rework Station TABLE OF CONTENTS

SMD Rework Station TABLE OF CONTENTS SMD Rework Station Thank you for purchasing the Hakko 50B SMD Rework Station. The Hakko 50B is designed to solder and desolder surface mounted devices with hot air. Please read this manual before operating

More information