Low-H2O valves Y EARS
|
|
- Stewart Brown
- 8 years ago
- Views:
Transcription
1 Low-O valves 0 Y EARS
2 Pre-settable valves Why a balancing thermostatic radiator valve? Due to the application of the specially designed Jaga and Jaga Danfoss pre-settable Trv s, the flowing water amount (Kv) in the heating elements can be exactly adjusted for an optimal performance of the Trv s. A similar Trv with built in balancing possibility may be regarded as having two control possibilities. One cut off gives a variable delimitation, determined by the required room temperature. The second cut off, by balancing, control of the maximum water flow can be achieved. Advantages: due to the correct quantity control of the required amount of water to the different heating elements energy is being saved. After the night period, when all Trv s are fully opened, the balancing control allows the furthest heating elements to get the required amount of hot water. The water flow temperature can be reduced earlier because of the uniform heating up of all heating elements what will restrict the energy loss. The noise of the flowing water will also be reduced thanks to the balancing flow control. The optimal water distribution allows a smaller water circulation pump to be installed. The water distribution to the different heating elements can easily be adapted when extending or changing the heating system. Without balancing TRV With balancing TRV The water distribution to the heating elements after the night low demand period when all Trv s are fully open. The system at the right has balanced Trv fitted, the left does not.
3 Position 90 Position 0 Connection possibilities Jaga Comap valve To the wall To the floor Jaga Pro valve To the wall With curves To the floor Top valve To the wall With -piece M 90 To the floor With -piece M 0 One pipe
4 Connection possibilities Jaga, Jaga type & Jaga Danfoss To the wall To the floor With lockshield / 90 and short sleeve couplings With lockshields / 90, extension pipe and short sleeve couplings Standard With extension pipe With lockshield / To the wall To the floor With extension pipe and -piece 90 M With angled lockshields / 90 (without opening for the thermostatic head in the side panel) With extension pipe and lockshield / 0 With extension pipe and lockshields / 0 With extension pipe and -piece M To the wall With type valve and angled lockshield M, 90 (only for Knockonwood and Strada type 0) To the floor With extension pipe and -piece /
5 Jaga Comap valve Thermostatic heads: see p. 9 Jaga Pro valve Thermostatic heads: see p EN. Knockonwood and Strada type 0, connection to the wall: see p.. Not suitable for Maxi and Cocoon. standard Kv 09.0 two pipe 09.0 one pipe - universal valve with revolving underblock for wall or floor connection - replacement internal mechanism - with screw thread M0 x. (eimeier compatible) - with synthetic spindle protection for setting on site - for one or two pipe - completely lockable (flow and return) Kv-value: - two pipe: continuous adjustable between 0.0 and m³/h - one pipe:. at position (0% of the waterflow through the radiator) EN. Knockonwood and Strada type 0, connection to the wall: see p.. Not suitable for Maxi and Cocoon. Sleeve couplings: see p.. - specially shortened thermostatic valve in order to be fully concealed within the casing - for one or two pipe standard Kv reduced Kv two pipe one pipe - with pre-setting at the flow (two pipe) or on the return (one pipe) - completely lockable (flow and return) - for connection to the floor or to the wall - with screw thread M0 x. (eimeier compatible) - with synthetic spindle protection for setting on site Standard Kv-value: - two pipe: 0. up to 0 m³/h. - one pipe: 0% up to 0% Reduced Kv-value: 0.0 up to 0. m³/h. (recognition: red coloured spindle protection). Sleeve couplings for Jaga Comap valve Curve 90 M x M / /... M See p.. Flexible steel or copper tube Description 09. ø / x / 09. ø / x / 09. ø / x / 09. ø / x / 09. ø / x / 0 90 use PFTE tape Synthetic or RPE/ALU tube Description. 09. ø / x / 09. ø / x / 09. ø / x / 09. ø / x / 09. ø / x / 09. ø / x / ø / x / ø / x 0/ Pro Key M 090. Tool for easy mounting of the Jaga Pro valve ø 0. Recognition one pipe valve. /" / Eurocone max. max. ø ø. ø.9 use PFTE tape max. max.. max. 9. /" M. Regulator screw (hex screw mm). Position see pressure drop graph. Recognition one pipe valve max. The valve extends to cm below the casing max. max. max.. ø. ø.9 max. 9
6 Jaga valve type Thermostatic heads: see p. 9 Sleeve couplings M - Jaga Pro and Jaga Type EN. M male thread, suited for shortened connection distance to the wall (up to. cm). See illustration p. / standard Kv reduced Kv - specially shortened thermostatic valve in order to be fully concealed within the casing - with pre-setting in steps - with screw thread M0 x. (eimeier compatible) - with synthetic spindle protection for setting on site. - for connection to the floor or to the wall Standard kv-value: - 0. tot 0 m³/h. Reduced kv-value: tot 0. m³/h. (recognition: red coloured spindle protection) For flexible steel or copper tube Description 09. ø M x / 09. ø M x / 09. ø M x / 09. ø M x / 09. ø M x / 09. ø M x / For synthetic tube Description 09. ø M x / 09. ø M x / 09.9 ø M x /, 09. ø M x / 09. ø M x / 09. ø M x / For RPE/ALU tube M M Just for tube / Connection sets & valves Lockshield M 90, connection to the wall M. /" 090. nickle-plated See p.. Application: only suitable for connection to the wall for Knockonwood and Strada type 0. Description 09. ø M x / 09. ø M x / 09. ø M x /. 09. ø M x / RPE tube = reticulated polyethylene tube with an intermediate aluminium layer. Steel tube for C.. Description 09.0 ø M x / 09.0 ø M x / M M G /" use PFTE tape. M. max. max.. max.. max.. ø. ø.9 ø max. 9
7 Jaga valve Thermostatic heads: see p. 9 Jaga Danfoss valve Thermostatic heads: see p. 9 EN. Knockonwood and Strada type 0, connection to the wall: see p standard Kv reduced Kv Standard kv-value: - 0. tot 0 m³/h. Reduced kv-value: tot 0. m³/h. (recognition: red coloured spindle protection) EN. Knockonwood and Strada type 0, connection to the wall: see p.. code Standard kv-value: up to 0. m³/h. Reduced Kv: - on request. - specially shortened thermostatic valve in order to be fully concealed within the casing - with pre-setting in steps - with screw thread M0 x. (eimeier compatible) - with synthetic spindle protection for setting on site. - for connection to the floor or to the wall use PFTE tape. G /" G /". max. max.. max.. max.. ø ø. ø.9 - specially shortened thermostatic valve in order to be fully concealed within the casing - integrated pre-setable water flow delimitation to control max amount of flowing water. - with synthetic spindle protection for setting on site. - for connection to the floor or to the wall use PFTE tape. G /" G /" ø. ø. max. 9 Sleeve couplings for Jaga & Jaga Danfoss valve For flexible steel or copper tube For RPE/ALU tube Description 09. ø / x / 09. ø / x / 09. ø / x / 09. ø / x / 09. ø / x / 09. ø / x / For synthetic tube / / Just for tube / Description 09. ø / x / 09. ø / x / 09. ø / x /. 09. ø / x / RPE tube = reticulated polyethylene tube with an intermediate aluminium layer. Steel tube for C.. / Description. 09. ø / x / 09. ø / x / 09.9 ø / x /. 09. ø / x / 09. ø / x / 09. ø / x / / Description 09.0 ø / x / 09.0 ø / x / Short coupling for flexible steel tube or copper tube Ø mm Description 09.0 ø / x / / /
8 Options for Jaga and Jaga Danfoss valve Extension pipe. Lockshield / 0 /" /" /" 09 nickle-plated Sleeve couplings / : see p.. See page nickle-plated Sleeve couplings / : see p.. See p.. -piece M 0 with integrated lockshields and lockable by-pass (one pipe/two pipe) /" /". M M nickle-plated Tool to regulate: mm Allen key. By-pass open: % of main pipe water flow goes through heating element. By-pass closed: 0 % of main pipe water flow goes through heating element. Sleeve couplings M: see p.. See p.. Connection sets & valves /" Lockshield / 90, connection to the wall /". /" -pipe adapter for crossway valve 090. nickle-plated Sleeve couplings / : see p See p.. -piece M 90 with integrated lockshields and lockable by-pass (one pipe/two pipe) by-pass..9. M /" /" nickle-plated Tool to regulate: mm Allen key. By-pass open: % of main pipe water flow goes through heating element. By-pass closed: 0 % of main pipe water flow goes through heating element. Sleeve couplings M: see p.. 9 See p. -. -piece / 0 with integrated lockshields and lockable by-pass (one pipe/two pipe) /" /". /" /" nickle-plated Tool to regulate: mm Allen key. By-pass open: % of main pipe water flow goes through heating element. By-pass closed: 0 % of main pipe water flow goes through heating element. Sleeve couplings / : see p.. See p. -. Adjusting the -piece (one pipe - two pipe) Radiatorflow Ra in % from water flow Number of rotations to open the by-pass
9 Jaga Top valve Thermostatic heads: see p. 9 For Linea Plus wall mounted model EN. When ordering a radiator with top valve, please specify the correct top valve position by adding /0 (left) or /0 (right) to the code of the radiator. Sleeve couplings To order sleeve couplings / : see p.. Thermostatic valve for operation at the top end, on the left or right side of the radiator. Applicable with all Low-O radiators with standard or Twin heat exchanger. After mounting only the thermostatic head remains visible at the side panel. Standard kv-value: - 0. up to 0 m³/h. Reduced kv-value: up to 0. m³/h. (only on request) - for connection to the floor or to the wall - the top valve is equipped with an air vent with transparent synthetic drain tube to collect the waste water at the bottom end of the radiator. - with synthetic spindle protection for setting on site. - with chromed cover ring to finish the opening for the thermostatic head in the side panel of the casing. - after mounting, this cover ring anchors the top valve with the casing. - suited for all Jaga thermostatic heads. - with pre-setting in steps - with screw thread M0 x. (eimeier compatible) Opening casing right left right or left right or left right or left 9 For Tempo wall mounted model Opening casing right left right left right or left right or left right or left right or left 90 For Tempo free-standing model Opening casing right or left right or left right or left 0 For Cocoon Opening casing right left right left right or left right or left right or left right or left 0 For Knockonwood For Maxi model WF/WT Opening casing right or left right or left right or left right or left 9 Opening casing right or left right or left right or left For Strada Opening casing right or left right or left right or left right or left 9 For Maxi model FF/FT Opening casing right or left right or left right or left
10 Thermostatic heads for all Jaga valves Thermostatic heads for Jaga Danfoss valve Technical data - Liquid filled Jaga and Jaga Deco thermostatic head: setting deviation 0. XP=K. - Maximum water flow temperature: C Jaga thermostatic head Deco thermostatic head Manual head Jaga remote controlled thermostatic head Length of capillary: m Minimal interior diameter of the tube for conducting the capillary = mm. 09 Jaga thermostatic head with sensor at distance Length of capillary: m white RAL 90 chrome chrome / white Jaga Comap silver white RAL Thermostatic head liquid filled with anti-freeze protection C. - min. and max. temperature control (- C) by ring-system. - screw connection M0 x. colour 090. chrome 090. chrome / white silver - liquid filled - anti-freeze protection C and regulable from up to C - (Jaga Comap: up to 0 C) - max. temperature control by pin on inside (Jaga Comap: ringsystem) - screw connection M0 x Remote controlled Trv head for heating elements installed in places with difficult access (underfloor ducts, bath panels, project casings, etc). Technical data: see Jaga thermostatic head Suitable for independent temperature measurement (underfloor ducts, bath panels, project casings, etc). Technical data: see Deco thermostatic head. Technical data - RA gas filled Jaga Danfoss thermostatic head and RAX liquid filled head: setting deviation 0. XP=K. - Maximum water flow temperature: C Thermostatic head Manual head < white RAL 90 type RA white RAL 90 type RAX chrome type RAX Remote controlled thermostatic head white RAL 90. Minimal interior diameter of the tube for conducting the capillary = mm. white RAL 90 Theft protection for Deco thermostatic heads Transparent synthetic theft protection white type RA white type RAX chrome type RAX Thermostatic head type RA: - with click-connection - gas filled Trv (super fast reaction) - anti-freeze protection. C. - locking pins by which the Trv can be blocked or limited both at a min. and max. temperature (- C) - locking pin as theft prevention Thermostatic head type RAX: - with click connection - liquid filled - anti-freeze protection C - regulable fom up to 0 C Remote controlled Trv head for heating elements installed in places with difficult access (underfloor ducts, bath panels, continiuous and project casings etc...) - length of capillary tube: m - remote sensor, wire and the setting knob are all liquid filled - anti-freeze protection. C - both the min. and max. temperature can be limited (- C) adapted screwdriver Connection sets & valves
11 Pressure drop 0 Technical data - Maximum water flow temperature: C - Max pressure of system: bar - Max pressure drop bar complying to the noise standard ISO Jaga Comap valve Jaga, Jaga Type, Jaga Pro and Jaga Top valve with standard Kv Pre-setting Kv: m /h/δp= bar 9 -PIPE (0% RA) Pre-setting Kv: m /h/δp= bar KvS Pipe Example: eat exchanger (Table ΔT=0) ΔT = C ( - = C) ΔP = 0. bar (to be setted over the valve) Pre-setting = Example: eat exchanger (Table ΔT=0) ΔT = C ( - = C) ΔP = 0. bar (to be setted over the valve) Pre-setting = mwk mce mws mwc bar 9 kpa mwk mce mws mwc bar Kvs kpa PIPE RA 0% Setting 0 db(a) db(a) db(a). 0. db(a) Pressure drop Pressure drop Water flow in kg/h Water flow in kg/h t= C t= C t= C t= C t=0 C t=0 C t=0 C t=0 C
12 Pressure drop Technical data - Maximum water flow temperature: C - Max pressure of system: bar - Max pressure drop bar complying to the noise standard ISO Jaga, Jaga Type, Jaga Pro and Jaga Top valve with reduced Kv Pre-setting Kv: m /h/δp= bar Example: KvS Pipe eat exchanger (Table ΔT=0) ΔT = C ( - = C) ΔP = 0. bar (to be setted over the valve) Pre-setting = Jaga Danfoss valve Pre-setting Kv: m /h/δp= bar Example: N NKVS open Pipe -Pipe eat exchanger (Table ΔT=0) ΔT = C ( - = C) ΔP = 0. bar (to be setted over the valve) Pre-setting = Connection sets & valves mwk mwk mce mce mws mws mwc bar Kvs kpa mwc bar N db(a) 0 db(a) db(a) 0 db(a) One pipe Nkvs -Pijp kpa Pressure drop Pressure drop Water flow in kg/h Water flow in kg/h t= C t= C t= C t= C t=0 C t=0 C t=0 C t=0 C
play Playful warmth, colourful comfort
play Playful warmth, colourful comfort 3 PLAY Playful warmth, colourful comfort Never have you seen so much colour in a single radiator. The Play4Girls or Play4Boys colour combinations create a cheerful
More informationData sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G
Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G EN 215-1 HD 1215-2 Application RA 2910 built-in sensor RA 2920 tamperproof RA 5062 remote sensor temperature adjuster RA-FN
More information1. Geo Vertical 2. Geo Horizontal
1 2 1. Geo Vertical 2. Geo Horizontal 1 2 3 1. Geo Vertical 2. Geo Vertical with towel rail 3. Geo Vertical with cover plate Geo Vertical 47 Geo Vertical Dimensions Connections Range GEVW_Geo Vertical
More informationRADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS
RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS MANIFOLD ASSEMBLIES ONE-PIPE Compatible with most radiators on the market, this pre-assembled manifold for one-pipe radiator systems delivers balancing
More informationInstallers and specifiers seeking information and advice on radiator thermostats and their application will find no better source than Danfoss.
DOMESTIC HEATING CONTROLS ARE EASY PART 5 - RADIATOR THERMOSTATS Fig.1. RAS-C 2 and RAS-D 2 radiator thermostats with RLV-D lockshield valve Radiator Thermostats (TRVs), the original and straight forward
More informationnew Twine & Pinch A tribute to the traditional column radiator Eyecatchers From design to art 2009 Ex
new Twine & Pinch A tribute to the traditional column radiator Eyecatchers From design to art 2009 Ex The information in this price list is correct at the time of printing. Jaga reserves the right to change
More informationBrochure 2012-2013.EX
VERTIGA Brochure 2012-2013.EX VERTIGA The new benchmark for design at super-low water temperatures The ultimate expression of form and function. Vertiga combines the power of Jaga Top Performers, the efficiency
More informationIntegrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U
Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows Application Integrated valves, type RA-N (013G1382) and RA- U (013G1383), with built-in presetting are designed for
More informationRadiator valve accessories 1-25-5
TOUR & ANDERSSON HYDRONICS AB Certification of Registration Number 2125 and 2125 M Certified by SP QUALITY AND ENVIRONMENT SYSTEM Radiator valve accessories 1-25-5 2001.04 1 Contents Accessories Presetting
More informationnew Eyecatchers From design to art 2008 Ex
new Eyecatchers From design to art 2008 Ex The information in this price list is correct at the time of printing. Jaga reserves the right to change product specification at any time in line with our policy
More informationIntegrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows
Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows Application Integrated valves, type RA-N (013G0372) and RA- U (013G0373), with built-in presetting are designed for incorporation
More informationThermostats. Technical information
Technical information Function: Oventrop thermostats and thermostatic valves are proportional regulators working without auxiliary energy. They regulate the room temperature by varying the flow volume
More informationEMO T. Thermal actuator for heating, ventilation and air conditioning systems
EMO T Thermal actuator for heating, ventilation and air conditioning systems Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEEING ADVANTAGE EMO T Description The EMO T thermal
More informationThermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)
- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVK can be combined with: - 2-way valves RAV-/8, VMT-/8, VMA, or - 3-way valves
More informationThermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)
- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVK can be combined with: - 2-way valves RAV-/8, VMT-/8, VMA, or - 3-way valves
More information2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications
Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?
More informationTechnical catalogue convectors POLAND 2012
Technical catalogue convectors POLAND 2012 index convectors review...3 Narbonne...4 Narbonne VT... 10 Narbonne V... 16 Narbonne V VT... 20 mounting distances for Narbonne...26 mounting distances for Narbonne
More informationThermostatic Actuators
2 111 EN 215-1 RTN51 with remote sensor RTN81 with remote adjuster Thermostatic Actuators for radiator valves VDN, VEN, VUN, VPD and VPE RTN51 RTN81 Self-acting, without auxiliary power High-quality fluid-filled
More information1. Taboe Sani 2. Taboe 3. Taboe Freestanding
1 2 3 1. Taboe Sani 2. Taboe 3. Taboe Freestanding 72 1 2 1. Taboe Sani Single 2. Taboe Sani Double 74 Taboe Sani 75 Taboe Sani Dimensions TSSW_Taboe Sani Single Wall Connections Code: 1 number = flow
More informationThermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)
- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) Description RAVV can be combined with 2-way valves RAV- /8, VMT-/8 or VMA 15. Controller closes on rising temperature. There is a special
More informationAutomatic Bypass Control AVDO
Application AVDO is a self-acting constant flow control primarily used either to maintain minimum flow rates through e.g. a low-capacity gas boiler or to control the differential pressure in a central
More informationHow To Buy A Designo Grille
anal ompact anal Plus 1 2 3 1. omplete anal Plus underfloor unit 2. Heat exchanger and inside finish of the duct in dark grey 3. Enlarged range of grilles anal Plus Operating principal Options Flexible
More informationstainless steel pre-assembled manifolds
TECHNICAL CATALOGUE stainless steel pre-assembled manifolds TEC ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and
More informationTHERMOSTATIC ACTUATORS WITH LIQUID-FILLED SENSITIVE ELEMENTS AND TEMPERATURE LOCKING
0A-GB THERMOSTATIC ACTUATORS WITH LIQUID-FILLED SENSITIVE ELEMENTS AND TEMPERATURE LOCKING SERIES SD - CD - GA MAIN CHARACTERISTICS - Available in the versions: Standard With Remote Sensor With Remote
More informationECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
More informationData sheet Thermostatic sensors type RA 2000
Thermostatic sensors type RA 2000 EN 215-1 RA 2990 RA 2992 RA 2920 RA 5060 RA 5074 Application The RA series is a comprehensive programme of radiator thermostats which covers all central and district heating
More informationBrochure 2012-2013.EX
CLIMA CANAL Brochure 2012-2013.EX CLIMA CANAL Complete climate control and high power Heating, cooling, ventilation. Despite it s modest size, clima canal is a powerful heating, cooling and ventilation
More information1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None
1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements
More informationValve range. To be precise.
Valve range To be precise. Thermostatic room temperature control Thermostatic head K with built-in sensor. Graduation cap white RAL 9016, Graduation cap chrome-plated, Graduation cap anthracite grey RAL
More informationThermostatic element RAVV for 2-way valves
Description / Application RAVV is a self-acting thermostatic element which can be combined with 2-way valve bodies RAV-/8, VMT-/8 or VMA 15. RAVV is used to control temperatures in small hot water cylinders
More informationThermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)
- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVI is self-acting thermostatic actuator primarily for use for temperature control
More informationSelect Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
More informationHDA -----------------------------------------------------------
----------------------------------------------------------- Lightstrips ---------------------------------------------------------------------- Ceiling system for heating and cooling LIGHTSTRIPS LIGHTSTRIPS
More informationThermostatic valve Type AVTA
MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The
More informationThermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity)
Data Sheet Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity) Application RAS-C² thermostatic sensor RA-FN angle valve The RAS-C² thermostatic sensor is a selfactuating proportional
More informationMAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure
MAKING MODERN LIVING POSSIBLE Thermostatic valve AVTA Technical brochure 2 IC.PD.500.A3.02-520B3728 Danfoss A/S 07-2009/ RA-MC/mr Contents Page Features............................................................................................4
More informationLEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34
LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34 2 LEVEL GAUGES WITH MAGNETIC JOINT SIZE Ø 140/220/340 58 58 TYPE LA TYPE LA 14 30 S 22 33 TYPE LA 22-34 NO. HOLES Ø D2 76 O-RING CENTRE OF THE CONSERVATOR
More informationUNDERSTANDING CENTRAL HEATING SYSTEMS
UNDERSTANDING CENTRAL HEATING SYSTEMS This advice guide is part of a series of free guides produced by the Association of Plumbing & Heating Contractors Ltd. which provide consumers with essential basic
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationSTABITHERM INSTALLATION & SERVICE BOOKLET
STABITHERM INSTALLATION & SERVICE BOOKLET TABLE OF CONTENTS Introduction...3 Warranty...3 Product Range and Physical Description...4 Method of Operation...5 Recommended Pressures and Temperatures...6 Flow
More informationINNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
More informationWorth noting. Use. Key figures. Installation. lindab atrium - loggia
Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / Premax / Solus Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Fasadium Atrium / Loggia
More informationCOMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions
COMPUTHERM Q7 Programmable, digital room thermostat Operating Instructions GENERAL DESCRIPTION OF THE THERMOSTAT The COMPUTHERM Q7 type switched-mode room thermostat is suitable to regulate the overwhelming
More informationElegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner
Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of
More informationData sheet ECC 12 and 22
Application ECC is an electronic room temperature controller for water-based systems. ECC can control - fan-coil units - inductions units - air conditioning systems - small ventilating systems - 2-pipe
More informationSeated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange
Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications. The
More informationMikrotherm. Manual radiator valves. To be precise.
Manual radiator valves To be precise. Description HEIMEIER Mikrotherm manual radiator valves made of corrosion-resistant gunmetal, with white plastic hand wheel cap, tight-packed with protection film.
More informationInstallation Instructions
Installation Instructions S50-310 (Semi-Circular) S50-311 (Circular) Accu-Zone Infrared Control Conversion Kit for Terrazzo & Stainless Steel Classic Washfountains (Non-sectional) Table of Contents Pre-Installation
More informationPRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE
Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface
More informationLaddomat 21-60 Charging unit
Laddomat 21-60 Charging unit User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according to the
More informationDERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description
Description Compact air/water heat pump for outside installation. With suction gas cooled rotary compressor. With extensive aluminium/cu lamellar tube evaporator and PVC Titanium condenser. Axial fan Refrigerant
More informationTechnical data. Danfoss DHP-A
Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs
More informationREGULATORS 175/153 Series
175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed
More informationWTW SWANTM. Linear slot air diffusers of wall-to-wall design for ceilings
SWANTM WTW Linear slot air diffusers of wall-to-wall design for ceilings Quick facts Wall-to-wall installation Diffuser face of light aluminium design 2, 3 or slots Horizontal/vertical air distribution
More informationArt.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
More informationDescription of functions
Description of functions Laddomat 21 is designed to......allow the boiler to reach a high working temperature soon after firing....to preheat the cold tank water in the bottom of the boiler so that the
More informationVITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A
Technical Data Manual Model Nos. and pricing: see Price List Vacuum tube collector based on the heat pipe principle For the utilisation of solar energy VITOSOL r 200-T SP2A Product may not be exactly as
More informationHEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
More informationPowers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat
Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual
More information3217 North Pulaski Road Chicago, Illinois 60641 Phone: (773) 685-7300 Fax: (773) 685-7332
327 North Pulaski Road Chicago, llinois 6064 Phone: (773) 685-7300 Fax: (773) 685-7332 NO. 7 SERES AUTO-VENTS" Air Eliminators For Hot Water Heating and Chilled Water Cooling Systems. For continuous venting
More informationMAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating
MAKING MORN LIVING POSSIBLE Danfoss heating living connect Installation and User Guide Contents 1.0 System overview... 3 2.0 Overview of display and control buttons... 3 3.0 Installation - step by step...
More informationQuinta Range. Condensing Boilers REMEHA QUINTA RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission
Quinta Range Condensing Boilers REMEHA QUINTA RANGE High efficiency wall hung condensing boiler with ultra low NOx emission QUINTA RANGE OUTPUTS Q30: 5.6-28 kw Q45: 7-40 kw Q65: 11-61 kw Q85: 14.4-84.2
More informationM SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A
Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000
More informationRVL470. Heating Controller. Building Technologies HVAC Products. Series B
2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones
More informationProgrammable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains
Drayton Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Invensys Controls Europe Technical Helpline: +44 (0) 845 130 7722 www.draytoncontrols.co.uk Installation
More informationPIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT
PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT GENERAL INFORMATION 1.1 This section applies to piping systems for chilled water, hot water, condenser water, steam, condensate return, fuel oil, refrigerant
More informationAutomatic control equipment for HVAC systems
Automatic control equipment for HVAC systems Products for domestic and industrial installations In buildings, the main aim of the installations is to guarantee and maintain a comfortable ambient. Watts
More informationFlow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting
Data sheet Flow controller with integrated control valve (PN 16, 5, 40*) AFQM, AFQM 6 - return and flow mounting Description AFQM 6 DN 40, 50 AFQM DN 65-15 AFQM DN 150-50 AFQM(6) is a self-acting flow
More informationPowers Controls TH 192 HC Heating/Cooling Room Thermostat
Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional
More informationHitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE
Hitachi Air Conditioning Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Contents Page 04 Product Range 08-09 RAC Summit Wall Mounted 10 RAC Shirokuma Wall mounted 11 RAC S Series - Wall
More informationRRV934. Multi-controller. Synco living
s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard
More informationhttp://dealer.truma.com/_parts/viewer/toolbar.html
Page 1 of 6 Truma/HEATING SYSTEMS/Trumatic C,.../Spare parts.../c 6002, from 06/97 Page 2 of 6 Part- Page 3 of 6 Pos. 001 002 003 005 006 007 008 010 010 011 012 013 014 015 016 017 018 019 020 021 022
More informationECOSTYLE RADIANT PANELS Installa on and Opera on Manual 2013
ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 0 QUALITY 0 YEAR GUARANTEE Exclusively distributed by: Table of contents Panel radiators General / Guarantee Technical data and radiator dimensions
More informationQualification Guide. BPEC 601/2514/7 - Level 1 Diploma in Plumbing Foundation. BPEC 600/9432/1 - Level 2 Diploma in Plumbing Foundation
Qualification Guide BPEC 601/2514/7 - Level 1 Diploma in Plumbing Foundation BPEC 600/9432/1 - Level 2 Diploma in Plumbing Foundation BPEC 600/5270/3 - Level 2 NVQ Diploma in Plumbing and Heating BPEC
More informationAutomatic balancing valves ASV
Automatic balancing valves ASV ASV-P ASV-PV ASV-PV ASV-PV ASV-BD ASV-I ASV-M 15-40 15-40 50 65-100 15-50 15-50 15-50 Description / Application ASV balancing valves are used for dynamic hydronic balance
More informationMFP14, MFP14S and MFP14SS Automatic Pumps
Page 1 of 6 TI-P136-02 ST Issue 12 Cert. No. LRQ 0963008 ISO 9001, S and SS utomatic Pumps Description The Spirax Sarco automatic pump is a displacement receiver operated by steam or compressed air. It
More informationThermometer in stainless steel with capillary and switch contacts
Design Type Case diameter Thermometer in and switch contacts 7308 = back flange for wall mounting 7312 = front flange for panel mounting 7310 = mounting bracket for wall mounting Dim 100 mm or 160 mm Accuracy
More informationZip Hydroboil Plus Cuts energy consumption dramatically
Instant Boiling Water Zip Hydroboil Plus Cuts energy consumption dramatically Extended Range Zip is the clear UK market leader in instant boiling water systems with our products in daily use in tens of
More informationButterfly Valves PN 6/10/16 for flanged connection
4 136 ACVATIX Butterfly Valves PN 6/10/16 for flanged connection tight-closing VKF46.. VKF46..TS Grey cast iron housing EN-GJL-250 (to DN 300) nodular cast iron housing EN-GJS-400-15 (from DN 350) DN 40
More informationMAKE OF AUTOMOBILE: NUMBER : 076/0800901 DATE : 2008-12-08 Copyright Prins Autogassystemen B.V. 2008 VERSION NR : 2008-10-24 B
MAKE OF AUTOMOBILE: HONDA TYPE: CIVIC PISTON DISPLACEMENT: 1800 NUMBER OF VALVES: 16 ENGINE NUMBER: R18A TYPE VSI INJECTOR ( COLOR ) ORANGE MODEL YEAR: 2008 ENGINE SET NUMBER 348/0250200.07 NUMBER : 076/0800901
More informationRadio controlled, programmable radiator thermostat RA PLUS-w
Data Sheet Radio controlled, programmable radiator thermostat RA PLUS-w Application RA-PLUS-w is a radio controlled radiator thermostat that enables users to lower the individual room temperature by approx.
More informationCRAC Precision climate control units for data centres
CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have
More informationHose and Tube Fittings Series 1-3
Embracing Challenge Hose and Tube Fittings Series 1-3 out of plastics PP, PVDF, PTFE Series 1 Special Features Corrosion resistant Gas tight Easy to handle Different connection threads Application Hose
More informationLK Wallbox UNI Push. Assembly. Only intended for LK PE-X Universal Pipe X.
LK Wallbox UNI Push Only intended for LK PE-X Universal Pipe X. LK Wallbox UNI Push 16 Single Article no. 188 06 38 LK Wallbox UNI Push 20 Single Article no. 188 06 39 LK Distance template LK Wallbox UNI
More informationTHERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494
THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494 1. BEFORE YOU BEGIN IMPORTANT INSTRUCTIONS READ AND SAVE FOR THE CONSUMER WARNING: Risk of scalding or other severe injury. Before completing installation,
More informationThe "DAVID" Steam Engine By Alan Marconett Hobbit Engineering HTTP://WWW.HobbitEngineering.com Alan@HobbitEngineering.
The "DAVID" Steam Engine By Alan Marconett Hobbit Engineering HTTP://WWW.HobbitEngineering.com Alan@HobbitEngineering.com (c) 2/20/03 The David steam engine is a simple oscillating steam engine, many plans
More informationInstallation Guide for Hive Active Heating
Installation Guide for Hive Active Heating Important note: Installation should only ever be carried out by a qualified engineer. Technical Support If you need to contact Hive s Technical Support team during
More informationLaddomat 21 Charging Unit
Laddomat 21 Charging Unit Part.No. 11 23 78 User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according
More informationOLI. Oil level indicator
OLI Oil level indicator Oil level indicator Unexpected or accidental oil leakages may occur randomly along transformer s lifetime. Clear indication of oil level inside transformer tank and on load tap
More informationDrayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
More informationMAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions
MAKING MODERN LIVING POSSIBLE living connect Installation and User Guide Danfoss Heating Solutions 2 living connect Thank you for buying a Danfoss product Danfoss Heating Solutions 3 Contents 1. System
More informationHARTING Ethernet Cabling 4-poles Overview
Ethernet Cabling 4-poles Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] Connectors [on page 22] System cables [on page 24] Panel feed-throughs
More informationJaga Low-H2O hydronic heating. Fin tube elements for low water temperatures and condensing boilers
Jaga Low-H2O hydronic heating Fin tube elements for low water temperatures and condensing boilers 2 = low water content = faster radiator = lower consumption = lower air pollution 3 Saving energy... gaining
More informationMorco House Riverview Road Beverley HU17 0LD. Retrofit or Upgrade a Water Heater in a Caravan Holiday home
Morco House Riverview Road Beverley HU17 0LD Morco Products Ltd Tel: 01482 325456 Fax: 01482 212869 Email sales@morcoproducts.co.uk Web www.morcoproducts.co.uk Retrofit or Upgrade a Water Heater in a Caravan
More informationOperators manual Basic water heater
Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,
More informationPlease also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk
1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance
More informationMEASURING AND LEVELING TOOLS
MEASURING AND LEVELING TOOLS LASER LEVELING FAST AND ACCURATE LEVELING Earth moving, laying of floors, interior design and set up; all applications for our laser and optical levels to prove their accuracy,
More informationVOYAGER 570G. 744A Sprayer Control
VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER
More informationBEDIENUNGSANLEITUNG Tieftemperaturheizkörper. MANUAL Low temperature radiator. NOTICE D UTILISATION E2 Radiateur basse température
Technology BEDIENUNGSANLEITUNG Tieftemperaturheizkörper MANUAL Low temperature radiator NOTICE D UTILISATION E2 Radiateur basse température INSTRUKCJA OBSŁUGI Grzejnik niskotemperaturowy NÁVOD PRO OBSLUHU
More informationAirline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts
Lo w p r o f i l e small air handlers and extract fan units Duties to 0.55m 3 /sec Available with the Electroline fitted control panel Ceiling void friendly - unit heights from 190mm to 350mm Airline VES
More information