Interface Protocol v1.2
|
|
- Marion Scott
- 8 years ago
- Views:
Transcription
1 Interface Protocol v1.2
2 Uart Configure on PC Baud Rate Bits Stop bits Parity 9600 bps 8 Bits 1 Bit No Parity Basic Uart Transfer Format Start 0/1 : These bytes are both 0x55. Control : This byte is controling meter. : The byte is the length of data. : These bytes are meter transfer to PC. : This byte is sum of all data array without carry. Command Format List Control Content 0x00 Read all data of meter 0 byte 52 bytes 0x11 Read log Amount & Type 0 byte 3 bytes 0x12 Read Pause & Period Amount 0 byte 2 bytes 0x13 Read Store Amount 0 byte 2 bytes 0x18 Command meter to Enter Download mode 0 byte 0 byte 0x19 Command meter to Exit Download mode 0 byte 0 byte 0x1A Read of EEPROM 4 bytes 1-64 byte 0x81 Write Model Name to EEPROM 10 bytes 1 byte 0x82 Write Serial Number to EEPROM 8 bytes 1 byte
3 Command Format Illustrate 0x00 : Read all data of meter 0x55 0x55 0x00 0x00 0xAA 0x55 0x55 0x00 0x36 See Below 0x?? Byte[0 9] : Model Name [0 9], total 10 bytes, ASCII code format Byte[10 17] : Serial Number [0 7], total 8 bytes, ASCII code format Byte[18, 19] : Firmware Version[0, 1] Byte[20] : Rotary Code Byte[21] : Blue Code Blue 0x00 0x01 0x02 0x03 Rotary 0x00 Temp. C Temp. F 0x01 AC V DC V AC+DC V 0x02 AC mv DC mv AC+DC mv 0x03 Ohm Beeper Cap Diode 0x04 AC ma DC ma AC+DC ma 0x05 AC A DC A AC+DC A 0x06 Hz / % Hz / DF Byte[22] : Key Code Byte[23] : Range Code Byte[24] : Meter Status Code Bit Hi Lo 0 Manual Range Auto Range 1 Manual Test Auto Test 2 Display : 10,000D Display : 100,000D 3 X 4 HFR AC AC 5 Auto Test (Rotary in Ohm) Manual Test (Rotary in Ohm) 6, 7 X
4 Byte[25 37] : Calibration, total 13 bytes Byte[38 40] : Main Display [0 2]; 24 bits signed number Byte[41, 42] : Main Display Status [0, 1] Byte[43 45] : Sub Display [0 2] ; 24 bits signed number Byte[46, 47] : Sub Display Status [0, 1] Note : The display status format refer to table 1/2/3 Byte[48 54] : Calibration, total 5 bytes 0x11 : Read log Amount & Type 0x55 0x55 0x11 0x00 0xBB 0x55 0x55 0x11 0x03 See Below 0x?? Byte[0, 1] : log amount Byte[2] : log type 0x12 : Read Pause & Period Amount 0x55 0x55 0x12 0x00 0xBC 0x55 0x55 0x12 0x02 See Below 0x?? Byte[0, 1] : Pause & Period data amount
5 0x13 : Read Store Amount 0x55 0x55 0x13 0x00 0xBD 0x55 0x55 0x13 0x02 See Below 0x?? Byte[0, 1] : Store data amount 0x18 : Command meter to Enter Download mode 0x55 0x55 0x18 0x00 0xC2 0x55 0x55 0x20 0x00 0xCA 0x19 : Command meter to Exit Download mode 0x55 0x55 0x19 0x00 0xC3 0x55 0x55 0x20 0x00 0xCA
6 0x1A : Read of EEPROM Address 0x55 0x55 0x1A 0x04 See Below 0x?? 0x55 0x55 0x1A 1-64 of EEPROM 0x?? Address[0] : EEPROM No. (0 or 1) Address[1, 2] : Address of EEPROM (0x0000-0xFFFF) Address[3] : Readed of EEPROM 0x81 : Write Model Name to EEPROM 0x55 0x55 0x81 0x0A See Below 0x?? 0x55 0x55 0x7F 0x00 0x?? Byte[0 9] : Model Name [0 9], total 10 bytes, ASCII code format 0x82 : Write Serial Number to EEPROM 0x55 0x55 0x82 0x08 See Below 0x?? 0x55 0x55 0x7F 0x00 0x?? Byte[0 7] : Serial Number [0 7], total 8 bytes, ASCII code format
7 Format Store Max Stored Amounts : 1,000 Start Address : 400H at EEPROM No.0 End Address : 1788H at EEPROM No.0 : 5 bytes Format : MSB 2SB LSB Display Status [0] Display Status [2] 24 bits signed number Refer Table 1 Refer Table 4 Pause & Period Max Stored Amounts : 1,000 Start Address : 1800H at EEPROM No.0 End Address : 27A0H at EEPROM No.0 : 4 bytes Format : Pause Amount MSB Pause Amount LSB 16 bits unsigned number The datalog pause occered after the datalog no. log Max Stored Amounts : 20,000 Start Address : 2800H at EEPROM No.0 End Address : AEA0H at EEPROM No.1 : 5 bytes Format : Bit 7-4 Period Code Refer Table 5 Bit 3-0 Pause Time MSB Pause Time LSB 12 bits unsigned number Unit : sec, max 4095 sec MSB 2SB LSB Display Status [0] Display Status [1] 24 bits signed number Refer Table 1 Refer Table 2, 3
8 Table Table 1 : Display Status [0] Bit Display Unit : : None : V : mv : A : ma : db : dbm : mf : uf : nf : Gohm : Mohm 7, 6, 5, 4, : Kohm : ohm : % : MHz : KHz : Hz : Temp. C : Temp. F : sec : ms : us : ns Others : None Dot Point : 000 : : , 1, : : : Others : None Content
9 Table 2 : Display Status [1] Bit Content 7 Display Enable (0) / Display Disable (1) 6 Content : Number (0); Word (1) 5 Overload : Within Limit (0); OL (1) 4, 3, 2, 1, 0 Function : : None : Function of Rotary : Frequency : Cycle : Duty : Stamp (Store / Recall / Logout / Log Rate) : Store : Recall : Login Stamp : Logout : Log Rate : (Rel.) : % : Reference : Maximun : Minimun : Average : Peak Hold Max : Peak Hold Min : dbm : db : Auto Hold : Setup : Log Word : Log Max : Log Min : Log TP Others : None
10 Table 3 : Display (Display Status [1].6 = Word) Display Content 0x Er 0x FULL 0x Beep 0x A.P.O. 0x b.lite 0x HAZ. 0x ON 0x OFF 0x RESET 0x START 0x00000A VIEW 0x00000B PAUSE 0x00000C FUSE 0x00000D ProbE 0x00000E def 0x00000F Clr 0x (S/W Version) 0x Er1 0x Er2 0x Er3 0x x x TEST
11 Table 4 : Display [2] Bit Content 7 Display Enable (0) / Display Disable(1) 6 Content : Number (0); Word (1) 5 Overload : Within Limit (0); OL (1) 4, 3, 2, 1, 0 Function : : None : AC V : DC V : AC+DC V : AC mv : DC mv : AC+DC mv : Ohm : Beeper : Cap : Diode : AC A : DC A : AC+DC A : Hz : DF : Temp. C : Temp. F : AC ma : DC ma : AC+ DC ma Others : None Table 5 : Period Code Period Code 0x sec 0x01 1 sec 0x02 10 sec 0x03 30 sec 0x04 60 sec 0x sec 0x sec 0x sec 0x sec 0x sec 0x0A 480 sec 0x0B 600 sec Period Time
Nemo 96HD/HD+ MODBUS
18/12/12 Pagina 1 di 28 MULTIFUNCTION FIRMWARE 2.30 Nemo 96HD/HD+ MODBUS COMMUNICATION PROTOCOL CONTENTS 1.0 ABSTRACT 2.0 DATA MESSAGE DESCRIPTION 2.1 Parameters description 2.2 Data format 2.3 Description
More informationRFID MODULE Mifare Reader / Writer SL031 User Manual Version 2.7 Nov 2012 StrongLink
RFID MODULE Mifare Reader / Writer User Manual Version 2.7 Nov 2012 StrongLink CONTENT 1. MAIN FEATURES... 3 2. PINNING INFORMATION... 4 3. BAUD RATE SETTING... 5 4. COMMUNICATION PROTOCOL... 5 4-1. Communication
More informationRFID MODULE Mifare Reader / Writer SL032 User Manual Version 1.5 Nov 2012 StrongLink
RFID MODULE Mifare Reader / Writer User Manual Version 1.5 Nov 2012 StrongLink CONTENT 1. MAIN FEATURES... 3 2. PINNING INFORMATION... 4 3. BAUD RATE SETTING... 5 4. COMMUNICATION PROTOCOL... 5 4-1. Communication
More informationRFID MODULE Mifare Reader / Writer SL025B User Manual Version 1.4 Nov 2012 StrongLink
RFID MODULE Mifare Reader / Writer User Manual Version 1.4 Nov 2012 StrongLink CONTENT 1. MAIN FEATURES... 3 2. PINNING INFORMATION... 4 3. BAUD RATE SETTING... 5 4. COMMUNICATION PROTOCOL... 5 4-1. COMMUNICATION
More informationData Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide
Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide Sensors LCD Real Time Clock/ Calendar DC Motors Buzzer LED dimming Relay control I2C-FLEXEL PS2 Keyboards Servo Motors IR Remote Control
More informationBrunata Optuna W (171)
Brunata Optuna W (171) Communication description Edition 1.1 UK-QB101414 / 26.02.2013 Brunata a/s is a Danish owned company. We have more than 90 years of experience within developing and producing meters,
More informationApplication Note. Introduction AN2471/D 3/2003. PC Master Software Communication Protocol Specification
Application Note 3/2003 PC Master Software Communication Protocol Specification By Pavel Kania and Michal Hanak S 3 L Applications Engineerings MCSL Roznov pod Radhostem Introduction The purpose of this
More informationNHD-0420D3Z-FL-GBW-V3
NHD-0420D3Z-FL-GBW-V3 Serial Liquid Crystal Display Module NHD- Newhaven Display 0420-4 Lines x 20 Characters D3Z- Model F- Transflective L- Yellow/Green LED Backlight G- STN-Gray B- 6:00 Optimal View
More information72-7730 72-7732 Intelligent Digital Multimeters
72-7730 72-7732 Intelligent Digital Multimeters Model 72-7730/72-7732 OPERATING MANUAL TABLE OF CONTENTS CHAPTER TITLE PAGE 1. Before You Start Overview Inspection Safety Information Rules For Safe Operation
More informationDynatek 6080RS multimeter
Dynatek 6080RS multimeter Table of Contents Connection...1 Installing the software...1 Starting the communication...1 Other possibilities...2 File Management...2 Printer...2 Graph screen...3 Programmers
More informationConfigurable Events for APC Network Management Card
Configurable s for APC Network Management Card Table of Contents Silcon DP300E Series 3 Smart-UPS / Matrix 7 Symmetra 9 Symmetra 3-Phase 13 Environmental Monitor 21 Configurable s for APC Network Management
More informationUser's Guide. True RMS Industrial Multimeter
User's Guide 97650 True RMS Industrial Multimeter Ω C ã F ã 10A V µ 10A V ã ã ma A Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),
More informationData sheet Wireless UART firmware version 4.02
Data sheet Wireless UART firmware version 4.02 BLUETOOTH is a trademark owned by Bluetooth SIG, Inc., U.S.A. and licensed to Free2move Rev: 22 December 2008 Table of contents 1 GENERAL INFORMATION...4
More informationRPDO 1 TPDO 1 TPDO 5 TPDO 6 TPDO 7 TPDO 8
EN ZC - 6DI8DO CANopen I/O Module 6 Digital Input 8 Digital Output Or 8 Counters (3 bit) 8 Digital input 8 Digital output User Manual Contents: Features PDOs PDO Type Emergency Message Functional Diagrams
More information4511 MODBUS RTU. Configuration Manual. HART transparent driver. No. 9107MCM100(1328)
4511 MODBUS RTU Configuration Manual HART transparent driver No. 9107MCM100(1328) 9107 CONTENTS Introduction... 3 Modbus basics... 3 Modbus RTU... 3 Supported Function Codes... 3 Modbus Parameters and
More informationSite Master S251B Antenna and Cable Analyzer
Site Master S251B Antenna and Cable Analyzer Programming Manual Hand-Held Tester For Antennas, Transmission Lines And Other RF Components WARRANTY The Anritsu product(s) listed on the title page is (are)
More informationTable 1 below is a complete list of MPTH commands with descriptions. Table 1 : MPTH Commands. Command Name Code Setting Value Description
MPTH: Commands Table 1 below is a complete list of MPTH commands with descriptions. Note: Commands are three bytes long, Command Start Byte (default is 128), Command Code, Setting value. Table 1 : MPTH
More informationConsult protocol, Nissan Technical egroup, Issue 6
Consult protocol, Nissan Technical egroup, Issue 6 1. Electrical and Signaling protocol 1.1. Consult terminal or PC communications is via three wire bus. TX, RX and Async Clock. 1.2. TX data to ECU level
More informationTechnical Support Bulletin Nr.18 Modbus Tips
Technical Support Bulletin Nr.18 Modbus Tips Contents! Definitions! Implemented commands! Examples of commands or frames! Calculating the logical area! Reading a signed variable! Example of commands supported
More informationMCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual
MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual Version: 1.0.1 Dec. 2005 Table of Contents I. Introduction 2 II. Operations 2 II.1. Theory of Operation 2 II.2. Configuration (PC-PC
More informationModel UT71A/B OPERATING MANUAL
Model UT71A/B OPERATING MANUAL CHAPTER TITLE PAGE 1. 2. Before You Start Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols Getting Acquainted Turning
More informationRFID MODULE Mifare Reader / Writer SL030 User Manual Version 2.6 Nov 2012 StrongLink
RFID MODULE Mifare Reader / Writer User Manual Version 2.6 Nov 2012 StrongLink CONTENT 1. MAIN FEATURES... 3 2. PINNING INFORMATION... 4 3. DEVICE OPERATION... 5 3-1. Clock and Data Transitions:... 5 3-2.
More information3-Channel 0-20mA analyzer with CAN bus and logic output. A2C-mA-M12-X. General Description. Features. Specifications
3-Channel 0-20mA analyzer with CAN bus and logic output. A2C-mA-M12-X General Description The A2C-mA-M12 is a 0-20mA analyzer that can measure 3 x ma signals simultaneously. The analyzer can calculate
More informationHow To Send A Message From A Computer To A Computer (Iwea) On A Microsoft Macbook 2.5 (Isoa) To A Microsatellite 2.4 (Ios) On An Unix (Ise
1. PROTOCOL ASTRA COMMUNICATION PROTOCOL (via RS232C) Argentina specification (B0319G) 26 Oct 2004 METHOD TRANSMISSION CONTROL PROCEDURE BAUD RATE DATA BIT STOP BIT PARITY DATA COMMUNCATION ORDER CONNECTOR
More information1. SAFETY INFORMATION
RS-232 Sound Level Meter 72-860A INSTRUCTION MANUAL www.tenma.com 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter
More informationDolphin In-Circuit programming Updating Firmware in the field
Dolphin In-Circuit programming Updating Firmware in the field 1 Introduction In systems e.g. gateways, where an external microcontroller is connected to a Dolphin based product like a TCM300 it might be
More informationHCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply
1. INTRODUCTION HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply User Manual This family of efficient, upgraded SMPS with small form factor, auto cross over CV CC,
More informationFluke 3000 FC Series Test Tools Technical Data
Fluke 3000 FC Series Test Tools Technical Data Now compatible with Fluke Connect Mobile App Start building tomorrow s test tool system today with the Fluke 3000 FC Digital Multimeter. The new Fluke Connect
More informationVirtual Integrated Design Getting started with RS232 Hex Com Tool v6.0
Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0 Copyright, 1999-2007 Virtual Integrated Design, All rights reserved. 1 Contents: 1. The Main Window. 2. The Port Setup Window. 3.
More informationAPR-PRT3 Printer Module: C-Bus Programming Instructions
APR-PRT3 Printer Module: C-Bus Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us
More informationCTNET Field Protocol Specification November 19, 1997 DRAFT
CTNET Field Protocol Specification November 19, 1997 DRAFT Introduction Version 1.0 of CTNET will support the AB3418 protocol for communication to field controllers. AB3418 is a point-topoint protocol
More informationBinary Representation
Binary Representation The basis of all digital data is binary representation. Binary - means two 1, 0 True, False Hot, Cold On, Off We must tbe able to handle more than just values for real world problems
More informationGPS NTP TIME SERVER Rack Version V2.2x
GPS NTP TIME SERVER Rack Version V2.2x Device Description: GPS NTP Time Server is designed to synchronize local time and date of network devices such as PCs, routers. Devices synchronize their local time
More informationSoft-Starter SSW-06 V1.6X
Motors Energy Automation Coatings Soft-Starter SSW-06 V1.6X Serial Communication Manual Language: English Document: 0899.5731 / 04 Serial Communication Manual Series: SSW-06 V1.6X Language: English Document
More informationUser Manual. Thermo Scientific Orion
User Manual Thermo Scientific Orion Orion Star Com Software Program 68X637901 Revision A April 2013 Contents Chapter 1... 4 Introduction... 4 Star Com Functions... 5 Chapter 2... 6 Software Installation
More informationSMS based remote control system
EE 318 Electronics Design Project Report, EE Department, IIT Bombay, April 2006 SMS based remote control system Ashish Deswal ( 03007020 ) Shaleen Harlalka ( 03007015 ) Arjun Arikeri ( 03007032 ) Ashish
More information8-Port HDMI Switch USER MANUAL VS0801H
8-Port HDMI Switch USER MANUAL VS0801H FCC Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
More informationSoftware User Guide UG-461
Software User Guide UG-461 One Technology Way P.O. Box 9106 Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 Fax: 781.461.3113 www.analog.com ezlinx icoupler Isolated Interface Development Environment
More informationFluke 89-IV & 189 Event Logging
Fluke 89-IV & 189 Event Logging FlukeView Forms Technical Note One of the major features of the Fluke 89-IV & 189 meters are their ability to "do logging". This technical note explains what kind of logging
More information[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]
FG085 minidds Function Generator Manual of Operation Applicable Models: 08501, 08501K, 08502K, 08503, 08503K Applicable Firmware Version: 1 ) 113-08501-100 or later (for U5) 2 ) 113-08502-030 or later
More informationWIZnet S2E (Serial-to-Ethernet) Device s Configuration Tool Programming Guide
WIZnet S2E (Serial-to-Ethernet) Device s Configuration Tool Programming Guide Rev 0.2 This document describes how to make your own Configuration Tool for WIZ100SR, WIZ105SR and WIZ110SR of WIZnet. And
More informationGround Resistance Clamp On Tester
USER MANUAL Ground Resistance Clamp On Tester MODEL 382357 Introduction Congratulations on your purchase of Extech s 382357 Ground Resistance Tester. This Clamp on device allows the user to measure ground
More informationUser's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
More informationANR-PRF. INSTRUCTION MANUAL IM157-U-A v0.5 COMMUNICATION PROTOCOL ANR MULTIFUNCTION ANALYZER PROFIBUS DP-V0
INSTRUCTION MANUAL IM157-U-A v0.5 ANR-PRF COMMUNICATION PROTOCOL ANR MULTIFUNCTION ANALYZER PROFIBUS DP-V0 PROFIBUS AND ANR-PRF Profibus-DP is a multi-master systems. In the networks it s possible to have
More informationHOST Embedded System. SLAVE EasyMDB interface. Reference Manual EasyMDB RS232-TTL. 1 Introduction
Reference Manual EasyMDB RS232-TTL 1 Introduction This document explains how to use the interface EasyMDB RS232-TTL and describe the connections and the necessary commands for communicating with Cash System
More informationUser Manual. MODBUS-RTU Option Board for SV-iS5 Series. LG Industrial Systems
User Manual MODBUS-RTU Option Board for SV-iS5 Series Read this manual carefully before using the MODBUS-RTU Option board and follow the instructions exactly. After reading this manual, keep it at handy
More informationTechnical Datasheet Interface ACURO SSI / BiSS
General... 2 Electrical Data... 2 General Design... 2 Supply Voltage (SELV)... 2 Intrinsic current consumption (w/o output current)... 2 Resolution and Accuracy... 2 Incremental Signals A, B... 3 SSI...
More informationCommand Processor for MPSSE and MCU Host Bus Emulation Modes
Future Technology Devices International Ltd. Application Note AN_108 Command Processor for MPSSE and MCU Host Bus Emulation Modes Document Reference No.: FT_000109 Version 1.5 Issue Date: 2011-09-09 This
More information4-Channel Thermometer / Datalogger
USER GUIDE 4-Channel Thermometer / Datalogger RTD and Thermocouple Inputs Model SDL200 Introduction Congratulations on your purchase of the Extech SDL200 Thermometer, an SD Logger Series meter. This meter
More informationAPPLICATION NOTE # Using Sage SMOS for VoIP Testing, IP Phone to IP Phone TABLE OF CONTENTS
Product: 930A L3 Communications Test Set 935AT Communications Test Set APPLICATION NOTE # Using Sage SMOS for VoIP Testing, IP Phone to IP Phone TABLE OF CONTENTS Introduction... 2 Configuring 935AT #1
More information1.Eastron SDM220Modbus Smart Meter Modbus Protocol Implementation V1.0
1.Eastron SDM220Modbus Smart Meter Modbus Protocol Implementation V1.0 1.1 Modbus Protocol Overview This section provides basic information for interfacing the Eastron Smart meter to a Modbus Protocol
More informationHDMI Matrix Switch USER MANUAL VM0404H
HDMI Matrix Switch USER MANUAL VM0404H FCC Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
More informationGPS NTP TIME SERVER Rack Version V2
GPS NTP TIME SERVER Rack Version V2 Description: Server is dedicated to synchronize network devices local time/date to Universal Time (UTC) Devices synchronizing own local time through the NTP V3 protocol.
More informationSite Master S331D MS2712
Site Master S331D MS2712 MS2711D Spectrum Master Cell Master SiteMaster SpectrumMaster MS2712 MT8212A CellMaster MS2712 Site Master S331D/S332D Cable and Antenna Analyzer Site Master is the preferred cable
More informationDS1621 Digital Thermometer and Thermostat
Digital Thermometer and Thermostat www.dalsemi.com FEATURES Temperature measurements require no external components Measures temperatures from 55 C to +125 C in 0.5 C increments. Fahrenheit equivalent
More informationModel UT61A/61B/61C/61D/61E: OPERATING MANUAL. Table of Contents
P/N:110401103671 Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons
More informationDS1621 Digital Thermometer and Thermostat
www.maxim-ic.com FEATURES Temperature measurements require no external components Measures temperatures from -55 C to +125 C in 0.5 C increments. Fahrenheit equivalent is -67 F to 257 F in 0.9 F increments
More informationDual Display Digital Multimeter
Dual Display Digital Multimeter GDM-8246 GW INSTEK PART NO. 82DM-82460MG1 This manual contains proprietary information, which is protected by copyrights. All rights are reserved. No part of this manual
More informationQuick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
More informationEVAL-UFDC-1/UFDC-1M-16
Evaluation Board for Universal Frequency-to- Digital Converters UFDC-1 and UFDC-1M-16 EVAL-UFDC-1/UFDC-1M-16 FEATURES Full-Featured Evaluation Board for the Universal Frequency-to-Digital Converters UFDC-1
More information1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.
1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter
More informationDevelopment Kit EM4095 User s Manual
EM MICROELECTRONIC - MARIN SA Appte 405 Title: Product Family: Application te 405 Development Kit EM4095 User s Manual RFID Part Number: EMDB40 Keywords: RFID Design Tools Date: 5 September 00 TABLE OF
More informationUSR-TCP232-T Hard Version: V2.0 Doc Version: V1.1 2011-08-16
RS232 Serial TO Ethernet convert Module USR-TCP232-T Hard Version: V2.0 Doc Version: V1.1 2011-08-16 Jinan USR Technology Co., Ltd. works on LAN and WAN and wireless for MCU to Ethernet Solutions, Ethernet,
More informationCAM-VGA100 User Manual
CAM-VGA100 User Manual Release Note: 1. Jan 28, 2004 official released v1.0 2. Feb 24, 2004 official released v1.1 Fix the definition of verify code Fix the bug of unable jump to power save mode Fix the
More informationAutoRanging Digital MultiMeter
Owner's Manual AutoRanging Digital MultiMeter Model No. 82139 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance
More informationModel UT60A: OPERATING MANUAL. Table of Contents. Page 3 4 5 6 8 9 10 11 14 17 17 17 19 19
Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons Display Symbols Measurement
More informationModel 187 & 189. Users Manual. True RMS Multimeter
Model 187 & 189 True RMS Multimeter Users Manual ugust 2000, Rev.2, 6/02 2000, 2002 Fluke Corporation. ll rights reserved. Printed in U.S.. ll product names are trademarks of their respective companies.
More informationDT105X / PB105 Series
DT105 / Series Cash Drawer Trigger & Printer Beeper User's Manual TM951031-05 Contents Information... 1 Technical And Operational Description... 3 Connections Load Test Specifications......... 5 7 8 Communication
More informationDQ61. Temperature Monitoring Unit for Transformers and Other Electrical Machines. User Manual (Hardware Rel. 2.0 - Firmware Rel. 1.3.
Temperature Monitoring Unit for Transformers and Other Electrical Machines DQ61 User Manual (Hardware Rel 20 - Firmware Rel 133) Rev 0114_en 28/12/2012 1 General Information 3 2 How to use this manual
More informationFluke 3000 FC Series Test Tools Technical Data
Fluke 3000 FC Series Test Tools Technical Data Now compatible with Fluke Connect Mobile App Start building tomorrow s test tool system today with the Fluke 3000 FC Digital Multimeter. The new Fluke Connect
More informationLED Bulb Manual. Aeotec by Aeon Labs LED Bulb.
LED Bulb Manual Aeotec by Aeon Labs LED Bulb. Aeotec LED Bulb is a multi-coloured LED bulb which allows control (on/off/dim/colour change) via wireless Z-Wave commands. The LED Bulb can also communicate
More informationSRF08 Ultra sonic range finder Technical Specification
SRF08 Ultra sonic range finder Technical Specification Communication with the SRF08 ultrasonic rangefinder is via the I2C bus. This is available on popular controllers such as the OOPic and Stamp BS2p,
More informationAuto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL
Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL WARNING: READ AND UNDERSTAND THIS MANUAL BEFORE USING YOUR MULTIMETER. FAILURE TO UNDERSTAND AND COMPLY WITH WARNINGS AND OPERATING INSTRUCTIONS
More informationACR122 NFC Contactless Smart Card Reader
Datenblatt / Specifications ACR122 NFC Contactless Smart Card Reader Table of Contents 1. Introduction... 3 1.1. USB Interface... 3 2. Implementation... 4 2.1. Smart Card Reader Interface Overview... 5
More informationS4000TH HART. HART Communication Manual
HART Communication Manual The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by General
More informationProduct Information S N O. Portable VIP protection CCTV & Alarm System 2
Product Information S N O Portable VIP protection CCTV & Alarm System 2 G O V E R N M E N T A L S E C U R I T Y S O L U T I VIP KIT Rapid Deployment VIP Protection Kit The VIP KIT has been designed to
More informationBRMO 80 / ETH-IP. User Manual. Réf : MU-BRMO 80-ETH-IP-1.4-EN
User Manual Réf : MU-BRMO 80-ETH-IP-1.4-EN BALOGH SA 189, rue d Aubervilliers - C.P. 97 75886 PARIS Cedex 18 France Tél : 33 (0)1 44 65 65 00 Fax : 33 (0)1 44 65 65 10 e-mail : balogh@balogh-group.com
More informationwww.elektroexpressz.hu
www.elektroexpressz.hu 2013 1 UT10 SERIES / UT20 SERIES Modern Pocket - Size Digital Multimeters Pocket-Size Digital Multimeters UNI-T UT10A UT10A DC Voltage 400mV/4V/40V/300 ±(0.8%+1) AC Voltage 4V/40V/300V
More informationDifferent Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. www.apm-solutions.com Version 3.0
3DLevelScanner II Different Ways of Connecting to 3DLevelScanner II A.P.M Automation Solutions LTD. www.apm-solutions.com Version 3.0 2 Different Ways of Connecting to 3DLevelScanner II Version 3.0 Table
More informationSR450 RECEIVER OPERATING INSTRUCTIONS 1892 1128
SR450 RECEIVER OPERATING INSTRUCTIONS 1892 1128 These operating instructions are intended to provide the user with sufficient information to install and operate the module correctly. The Wood & Douglas
More informationSUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual
SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual Version 1.0 - January 20, 2015 CHANGE HISTORY Version Date Description of Changes 1.0 January 20, 2015 Initial Publication
More informationBluetooth HID Profile
RN-WIFLYCR-UM-.01 RN-HID-UM Bluetooth HID Profile 2012 Roving Networks. All rights reserved. Version 1.0r 1/17/2012 USER MANUAL www.rovingnetworks.com 1 OVERVIEW Roving Networks Bluetooth modules support
More informationPart Number Description Packages available
Features 3 digital I/O Serial Data output Connects directly to RF Modules Easy Enc / Dec Pairing Function Minimal External Components Required Performs all encoding/decoding of data for Reliable Operation.
More informationEmbest DSO2300 USB Oscilloscope
Embest DSO2300 USB Oscilloscope - 8-bit, 100Ms/s, 50MHz, 2-channel USB1.1/2.0 Compatible Digital Storage Oscilloscope - Multi-functions Including Logic Analyzer, Spectrum Analyzer (FFT), Record & Playback
More informationScanner Configuration
Scanner Configuration SmartScan Manual DOC Version 2.21 This document is specifically designed for the user to print two pages per sheet of paper with optimal print quality. Copyright 2005~ 2008 CIPHERLAB
More informationTS5010 TeraTune Programmable Bandpass Filter
FEATURES 0MHz to 90MHz Tunability 240 Frequency Steps Constant Q, Two-pole Butterworth Bandpass 1W Power Handling 0µs Tuning Speed Serial/Parallel Modes -40C to +85C DESCRIPTION The TS5010 series of TeraTune
More informationSample EHG CL and EHG SL10 16-bit Modbus RTU Packet
Sent to EHG - Read (16-bit) Process Value Controller 00000011 0x03 3 Function Code - Read Holding Registers 00000000 0x00 0 Read starting at register High byte (Process Value Controller is contained in
More informationNTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter
NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter Description: The NTE2053 is a CMOS 8 bit successive approximation Analog to Digital converter in a 20 Lead DIP type package which uses a differential
More information10. XBee Command Reference Tables
. XBee Command Reference Tables Addressing Addressing Commands Type Parameter Range Default DH DL MY MP NC Destination Address High.Set/Get the upper 32 bits of the 64-bit destination address. When combined
More informationM-Bus-Logger Data Logger
Data Logger User Manual Doc.-No.: E102312514074 Bär Industrie-Elektronik GmbH Rathsbergstr. 23 D-90411 Nürnberg Phone: +49 (0)911 970590 Fax: +49 (0)911 9705950 Internet: www.baer-gmbh.com COPYRIGHT Copyright
More informationCMC-DN01 DeviceNet Slave Communication Card Operation Manual
CMC-DN01 DeviceNet Slave Communication Card Operation Manual 2011-12-26-A Warning This operation manual provides introduction on the functions, specifications, installation, basic operation and settings
More informationA RF18 Remote control receiver MODULE
A RF18 Remote control receiver MODULE User Guide No part of this document may be reproduced or transmitted (in electronic or paper version, photocopy) without Adeunis RF consent. This document is subject
More informationUSB Card Reader Configuration Utility. User Manual. Draft!
USB Card Reader Configuration Utility User Manual Draft! SB Research 2009 The Configuration Utility for USB card reader family: Concept: To allow for field programming of the USB card readers a configuration
More informationVariable Preset Counter signo 723.1
Variable Preset Counter signo 723.1 Large, 6-digit, 14 mm high LED display Up/down counter with prescaler 2 presets, one programmable as trailing preset Easy direct selection by 2 function keys 2 relay
More informationPOS Integration. Prepared by: Binh Nguyen
POS Integration Prepared by: Binh Nguyen Point of Sale (POS) Compatibility To know whether it is possible to integrate your POS system with our DVR, please check whether the type of printer the POS system
More informationJNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
More informationSerial Communications / Protocol in AirTest Products
Serial Communications / Protocol in AirTest Products General The standard sensor has two different ways of serial communication with sensor s peripherals and the outside world. One is through the UART
More informationTemp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol
Temp-485-Pt100 A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol Temp-485-Pt100 Box version [600 113] Temp-485-Pt100 Cable version [600 114]
More informationANR INSTRUCTION MANUAL ELECTRICAL MULTIFUNCTION ANALYZER RECORDER COMMUNICATION PROTOCOL. ASCII standard ANR MODBUS-RTU
INSTRUCTION MANUAL IM145-U-A v5.8 ANR ELECTRICAL MULTIFUNCTION ANALYZER RECORDER COMMUNICATION PROTOCOL ASCII standard ANR MODBUS-RTU INSTRUCTION MANUAL IM 145-U-A v. 5.8 Firmware Vers. X.11.1E ANR protocol
More information115C and 117C. True-rms Multimeters. Users Manual
115C and 117C True-rms Multimeters Users Manual PN 2538695 July 2006, Rev. 1, 2/07 2006, 2007 Fluke Corporation, All rights reserved. Printed in China All product names are trademarks of their respective
More information