Appendice F. Specifiche Flexible cords and cables secondo NFPA 70 Appendix F. Flexible cords and cables according to NFPA 70
|
|
- Bernard Gibbs
- 8 years ago
- Views:
Transcription
1 Appendice F. Specifiche Flexible s and s secondo NFPA 70 Appendix F. Flexible s and s acing to NFPA 70 APPENDICE - APPENDIX Nella tabella che segue vengono definite le sigle utilzzate per definire le tipologie dei Flexible s and s mentre nella tabella successiva sono definite le caratteristiche ed i limiti di impiego. In the tables below identification letters for coding and types for Flexible s and s are specified. Tabella F.1. Sigle utilizzate per definire i Flexible s and s specificati nell Art. 400 del NFPA 70 (NEC) Ed. 2008/2011 Table F.1. Letters used for Flexible s and s coding specified in the Art. 400 of NFPA 70 (NEC) Ed. 2008/2011 Letter Description C Cotton or rayon braid. E As first letter: Elevator. E After first letter: elastomer insulation. H Heater. NI Non-integral used for parallel s such as NISPT-1 to denote insulated conductors and jacket are separate. O The jacket is oil resistant. OO The jacket and the conductor insulation are oil resistant. P Parallel conductor. S Extra hard usage Flexible Cord. SJ Hard usage Flexible Cord. SV Not hard usage Flexible Cord. T As first letter: Tinsel. Single flattened No. 27 AWG conductor wound around insulating core, for very low current, highly flexible application. T After first letter: insulation. -1, -2, -3 thickness for parallel s, thinnest to thickest. Actual insulation thickness varies with type and AWG size. XTW Parallel for decorative lighting strings. CXTW Twisted pair or single conductor for decorative lighting strings. W As last letter: Moisture and sunlight resistant. W As the only letter: Portable Power Cable. Esempi - Examples SOOW Extra hard usage, jacket and conductor insulation are oil resistant, moisture and sunlight resistant SJTO Hard usage, thermoplastic insulation, jacket is oil resistant 217
2 Tabella F.2. Specifiche per i Flexible s and s come specificato nell Art. 400 del NFPA 70 (NEC) Ed. 2008/2011 Table F.2. for Flexible s and s acing to Art. 400 of NFPA 70 (NEC) Ed. 2008/2011 Lamp C Pendant or portable. Dry locations min. 2 Elevator E Elevator lighting and control. Unclassified locations.. o 20 2 min. 2 Elevator EO Elevator lighting and control. Unclassified locations. o 20 2 min. 2 Elevator EO Elevator lighting and control. Hazardous (classified) locations. o 20 2 min. 2 ETP Hazardous (classified) locations. o - - Elevator ETT Hazardous (classified) locations. o - - EV EVJ min. 2 plus grounding conductor(s), plus optional hybrid data, signal communications, and optical fiber s. Electric vehicle EVE EVJE min. 2 plus grounding conductor(s), plus optional hybrid data, signal communications, and optical fiber s. EVT EKJT min. 2 plus grounding conductor(s), plus optional hybrid data, signal communications, and optical fiber s. Portable power G Portable and extra hard usage. G-GC plus grounding conductor(s) 3 6 plus grounding conductors and 1 ground check conductor Heater HPD Portable heaters. Dry locations , 3 or 4 o termoplastico or thermoplastic - - con nylon opzionale with optional nylon con nylon opzionale elastomer with optional nylon con nylon opzionale with optional nylon Tre strati di cotone, il più esterno resistente alla fiamma e all umidità Three cotton, Outer one flame-retardant & moisture-resistant Tre strati di cotone, il più esterno resistente alla fiamma e all umidità Three cotton, Outer one flame-retardant & moisture-resistant Cotone e guaina in neoprene One cotton and a neoprene jacket. Cotone o equivalemte e guaina termoplastica One cotton or equivalent and a thermoplastic jacket elastomer, oil-resistant, oil-resistant Cotone o rayon Cotton or rayon 218
3 APPENDICE - APPENDIX Parallel heater jacketed heater s Nonintegral parallel s Twisted portable Portable power Flexible stage and lighting power HPN Portable. Damp locations HSJ HSJO Portable or portable heater. Damp locations HSJOO , 3 or 4 NISP-1 NISP NISPE-1 NISPE NISPT NISPT PD Pendant or portable. Dry locations min. 2 PPE Portable, extra hard usage plus optional grounding conduttor(s) S min. 2 SC SCE Portable, extra hard usage min. 1 SCT SE SEW SEO SEOW SEOO SEOOW Pendat or portable. Damp locations. Pendat or portable. Damp locations and wet locations. Pendat or portable. Damp locations. Extra hard usage Pendat or portable. Damp locations and wet locations. Pendat or portable. Damp locations. Pendat or portable. Damp locations and wet locations min. 2, oil-resistant, oil-resistant elastomer o termoplastico or thermoplastic elastomer - elastomer elastomer oil resistant elastomer, oil-resistant Cotone e termoindurente Cotton and thermoset Cotone e termoindurente, oil-resistant Cotton and oil-resistant thermoset elastomer Cotone o rayon Cotton or rayon, oilresistant Oil-resistant thermplastic elastomer elastomer elastomer oil resistant elastomer 219
4 Junior hard service All thermoset parallel SJ SJE SJEW SJEO SJEOW SJEOO SJEOOW SJO SJOW SJOO SJOOW SJT SJTW SJTO SJTOW SJTOO 80 SJTOOW SO SOW SOO SOOW locations. locations. SP SP SP Refrigerators, room air conditioners, and as permitted in (B). Damp locations min. 2 elastomer, oilresistant elastomer, oil-resistant, oil-resistant, oil-resistant elastomer, oilresistant elastomer, oil-resistant, oil-resistant, oil-resistant 220
5 APPENDICE - APPENDIX All elastomer (thermoplastic) parallel All plastic parallel Range, dryer SPE SPE SPE Refrigerators, room air conditioners, and as permitted in (B). Damp locations SPT SPT-1W SPT SPT-2W locations SPT Refrigerators, room air conditioners, and as permitted in (B). Damp locations SRD or 4 Portable. Damp locations. Ranges, dryers. SRDE or 4 SRDT or 4 ST STW locations. STO min. 2 STOW locations. STOO STOOW elastomer elastomer, oil-resistant elastomer, oil-resistant 221
6 Vacuum cleaner Parallel tinsel Jacketed tinsel Portable power SV SVE SVEO SVO SVEOO SVOO o 3 SVT SVTO SVTOO TPT Attached to an appliance. Damp locations TST Attached to an appliance. Damp locations W Portable, extra hard usage elastomer, oil-resistant elastomer, oil-resistant, oil-resistant elastomer, oil-resistant elastomer, oil-resistant, oil-resistant, oil-resistant, oil-resistant, oil-resistant 222
600V Power Cable 600V SOOW SOW
600V Power Cable Type SOOW UL/CSA 90 C 600V Part AWG No of Insulation Jacket Nominal Wieght/Mft Number Stranding conductors Thickness Thickness O.D. Nom. 18 2 SOOW 18 AWG 2.30 71 18 3 SOOW 16/.010 3.030
More informationIndependent Agency Approvals & Certifications
Independent Approvals & Certifications E72853 E72853-B 13 Limited Circuit Cable PVC Insulation/PVC or CP Jacket CL2, CL3, PLTC 22-12 60-105 o C PVC Insulation/PVC or CP Jacket CL2, CL3 24-12 60-105 o C
More informationCarolprene CORD & CORDSET. This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123. Super Vu-Tron CarolFlex
CORD & CORDSET Super Vu-Tron CarolFlex Carolprene CORD & CORDSET PRODUCTS FOR INDUSTRIAL, COMMERCIAL AND SPECIALTY APPLICATIONS MARCH 2010 This catalog contains in-depth information on the most comprehensive
More information5.1 Cordoni elettrici di alimentazione 216 Power cord sets
5.0 Cordoni elettrici di alimentazione 215 216 IPXX Grado di protezione / IP protection degree Spedizione / Shipment Accessori / Accessories Stock / Stock Imballo pz / Packing pcs Attenzione / Attention
More informationCheck Ack s web site for price & availability: acksupply.com
SELECTION GUIDE Multiconductor Belden Cables Stranded PVC Jacket AWG 2. 3. 4. 5. 6. 7. 8. 9. 10. 12. 14. UN 8782 - - - - - - - - - - 8641 (O) 9452 (O) 9533* 9502 (O) 9534 (O) 9535 (O) 9503 (O) 9536 (O)
More informationElectrical Hazards. Power Tools. Extension Cords
Electrical Hazards Electrical hazards can be found in nearly every roofing work site. Whether the hazard is posed by worn or damaged power tools or cords, improperly grounded tools or equipment, or the
More informationSuper Vu-Tron Supreme Types SJOOW/SOOW 105ºC 300 and 600 Volt UL/CSA Portable Cord
Rubber Cord Super Vu-Tron Supreme Types SJOOW/SOOW 105ºC 300 and 600 Volt UL/CSA Portable Cord Cord & Cordset Conductors: 18 through 10 fully annealed stranded tinned copper per ASTM B-174 Premium-grade,
More informationElectrical Grounding. Appendix C
Appendix C Electrical Grounding Low-Voltage Equipment Grounding The most frequently cited Office of Safety and Health Administration (OSHA) electrical violation is improper occupational grounding of equipment
More informationBuilding Cables and Wires
Building Cables and Wires 4 Introduction alfanar is equipped with state-of-the-art manufacturing facilities such as latest machineries, instrumentation, quality control and testing laboratory, etc., for
More informationELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST
Name of School: OPTIONAL INFORMATION Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST Guidelines: This checklist
More informationDIRECTCONNECT SERVICE
DIRECTCONNECT SERVICE PRE-ASSEMBLED: LEADS, GROUNDS AND STINGERS/WHIPS Save Time, Labor and Money Lead Stinger/Whip Stock Colors (Blue, Green, Red, Yellow) available Stocked genuine Lenco and Tweco Connectors
More informationSUBJECT: NO MORE 300 VOLTS IN PLTC PRINT LEGEND
Belden Electronics Division P.O. Box 1980 Richmond, Indiana 47375-1980 2200 U.S. Highway 27 South Richmond, Indiana 47374-7279 Telephone: 765 983 5200 Facsimile: 765 983 5825 SUBJECT: NO MORE 300 VOLTS
More informationHook-Up and Lead Wire
3.1 Hook-Up and Lead Wire 3 Table of Contents Hook-Up & Lead Wire Page Introduction: UL Style & CSA Type Listings 3.2 PVC 3.3 3.8 300V, 80 C 3.3 300V, 105 C 3.4 600V, 105 C 3.5 (Type MW) MIL-W-76C-PVC:
More informationWire Cable & Accessories Catalogue
Wire Cable & Accessories Catalogue Caliber United caters to industrial needs in the following sectors Oil, Gas & Petrochemical Industries Food & Packaging Offshore & Marine Sectors Power & Desalination
More informationChemical resistance Accidental
Industrial flexible cable, insulation and outer sheath in elastomer Description Application TITANEX flexible cable is intended for installations with moving equipment, electric appliances and for building
More informationUNDERSTANDING. C&M Corporation 51 South Walnut Street, Wauregan, CT 06387 Phone: 860.774.4812 Fax: 860.774.7330 www.cmcorporation.
UNDERSTANDING UNDERSTANDING NFPA 79 By Ned Lloyd and Mike Levesque NFPA-79 is the electrical standard that has been developed by the National Fire Protection Association (NFPA) and is intended to minimize
More informationAfter the Storm. Floodwater safety
After the Storm Floodwater safety Health Issues and Short Term Safety Floodwaters are likely to be contaminated with unknown chemicals, oils, sewage, fertilizers, bacteria, germs and silt. Any of these
More informationMicrophone and Musical Instrument Cable Overview
B R I L L I A N C E B R O A D C A S T C A B L E S 19.3 Microphone and Musical Instruent Cable Overview Flexible Microphone Cables Belden icrophone cable is used for connecting low level icrophones or usical
More informationThe National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables
The National Armored Cable Manufacturers Association Presents Installation Standard for Types AC and MC Cables An ANSI Standard Original document jointly produced by NECA and NACMA as Standard for Installing
More informationBasic Cable Assemblies DELIVERING QUALITY SINCE 1952.
Basic Cable Assemblies DELIVERING QUALITY SINCE 1952. Cable Types Cable Types Hook-up & Lead Wire Most Basic 2 Cable Types Cable Types Twisted Pair Cable A type of cable that consists of two independently
More informationLiebert GXT4 UPS 230V 700VA-3000VA. User Manual
Liebert GXT4 UPS 230V 700VA-3000VA User Manual TABLE OF CONTENTS IMPORTANT SAFETY PRECAUTIONS................................................1 GLOSSARY OF SYMBOLS........................................................3
More informationFLEXTREME AND FLEXTREME IF
FLEXTREME AND FLEXTREME IF SOOW / SJOOW Flexible Cord TF Cable manufactures a superior industrial cable that offers a high value cosmetic appearance and greater mechanical strength by eliminating design
More information2012 CATALOG AEROSPACE VVIRE & CABLE INC. aerospacewire.com
* 2012 CATALOG AEROSPACE VVIRE & CABLE INC. A VV aerospacewire.com W e p r o u d l y m a n u f a c t u r e h i - t e m p w i r e & c a b l e. PLENUM CABLE. INDUSTRIAL CABLE. TRAY CABLE. MILITARY WIRE.
More informationOntario Electrical Safety Code 25 th Edition/ 2012
Ontario Electrical Safety Code 25 th Edition/ 2012 Ted Olechna Director, Codes and Standard Chief Engineer 1 What I Will Cover ESA s role is as the regulator Highlight of 2012 Code changes The Code and
More informationMILITARY. Military DTL Part Number Key MIL-DTL-3432J. CO-Type Portable Power Cable. One source offering the broadest line of professional products
Military DTL Part Number Key Part Example: M3432-03 M G F (3/12) SJ 0515 Visit us online at www.colemancable.com Total Number of Conductors Duty Complete online catalog Downloadable spec sheets Technical
More informationTELE-FONIKA CABLE AMERICAS
TELE-FONIKA CABLE AMERICAS TELE-FONIKA CABLE AMERICAS (TF KABLE) is a US firm with corporate offices and main facility located in Bolingbrook, IL and is a wholly owned subsidiary of Tele-Fonika Kable SA.
More informationType XHHW-2 or RHH/RHW-2/USE-2 GenFree II LSZH XLPO Single Conductor
TABLE OF CONTENTS SECTION I. SUBJECT SCOPE 2 II. APPLICABLE DOCUMENTS 2 III. CONDUCTOR 3 IV. SEPARATOR 3 V. INSULATION 3 A. 3-4 B. Electrical Properties 4 C. Flame Resistance 5 D. Smoke and Halogen Testing
More informationDATA SHEET SERVO LK SMS FX8PLUS SIGNAL
Application LAPP servo cables according to Siemens * (see footnote) Standard FX8008 PLUS SIGNAL are a new generation of very highly flexible screened signal (encoder and resolver)- cables (P/Ns 00277101
More informationHARTING Ethernet Cabling 4-poles Overview
Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] HARTING PushPull Connectors [on page 22] System cables [on page 24] Panel feed-throughs [on
More informationThermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.
Thermwire Freeze Protection Heating Cable Selection Guide Pipe Freeze Protection Heating Cable Pre-Assembled Pipe Freeze Protection Heating Cable with Attached Cord & Plug Thermwire-Comp Refrigeration
More informationLIFE-LINE Safety Cables Continuous Bending Hi-Flex Electrical Cables to Guarantee Safe Cable & Hose Carrier Systems
LIFE-LINE Safety Cables Continuous Bending Hi-Flex Electrical Cables to Guarantee Safe Cable & Hose Carrier Systems Cost-Effective Safe Reliable: LIFE-LINE Cable Carrier Systems Designed by the Experts
More informationHOUSING QUALITY STANDARDS (HQS)
HOUSING QUALITY STANDARDS (HQS) Series 5 Electrical Safety And INSPECTIONS 5.01 ELS Revised 8-17-06 Electricity is Dangerous All electrical repairs should be made by licensed professionals. Touching any
More informationCable flexibility Flexible. Chemical resistance Accidental
H07RN-F Industrial flexible cable, insulation and outer sheath in elastomer Description pplication H07RN-F flexible cable is intended for installations with moving equipment, electric appliances and for
More information2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE
2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE PAGE 1 OF 5 This Reference provides a very comprehensive list of aspects of a solar PV installation that could be reviewed, clarifying
More informationGeneral Product Categories
General Product Categories WIRE * : Airframe Filter Line Motor Lead Tefzel TM Aircraft Hook Up Nuclear Test lead Automotive Irradiated Prebend TOP/TOC Bus Bar Kynar TM Silicone Rubber Wire Wrap Continuous
More information1394 locking cables. Your locking cables for AVT IEEE 1394 cameras
Your locking cables for AVT IEEE 1394 cameras AVT locking cables are ideal for connection of IEEE 1394 cameras in any industrial application. The high quality cables guarantee low damping and best signal
More informationRoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables
RoHS DATA, COAXIAL AND ELECTRONIC D A TA, C O A X I A L, A N D EL E CTRON I C Cables Index SOLID MULTI-CONDUCTOR CABLES STRANDED MULTI-CONDUCTOR CABLES SPEAKER/ZIP WIRE THERMOSTAT CABLE FIRE ALARM CABLE
More information7. What is the current in a circuit if 15 coulombs of electric charge move past a given point in 3 seconds? (1) 5 A (3) 18 A (2) 12 A (4) 45 A
1. Compared to the number of free electrons in a conductor, the number of free electrons in an insulator of the same volume is less the same greater 2. Most metals are good electrical conductors because
More informationELEVATOR TRAVELING CABLE - DESIGN EVOLUTION
ELEVATOR TRAVELING CABLE - DESIGN EVOLUTION by Richard Laney Introduction Elevator traveling cable is a vital link between the elevator car and controller. In conventional elevators, all power and signal
More informationCommunication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
More informationCable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range
HONEYWELL SECURITY & CUSTOM ELECTRONICS Cable Products Honeywell's Genesis Series provides a full range of low voltage cables for security, fire, sound, voice and data, video, structured cabling and other
More informationCurrent Transformer (CT) Selection Guide
Current Transformer (CT) Selection Guide Article ESA-1008D December 5, 2014 Contents 1 Introduction.............................................. 3 1.1 Extending CT leads.......................................
More informationCable and Cord Reels. Section R. Cable and Cord Reels Index. Index
Section R Index Product Page Number and R-2 3 Weatherproof Cable and Static Discharge Reels R-4 R-5 R-6 Index www.hubbell-wiring.com and and Hubbell Electric Cord and Cable Reels Hubbell Wiring Device
More informationGenerator DoCKInG StatIonS
Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed
More informationPREFACE. Your comments or suggestions are welcome and appreciated. They should be directed to:
PREFACE Each year, millions of feet of wire and cable are installed in all types of buildings and are subjected to many different environmental conditions. Because of the choices available, it is important
More informationSTR-600 Plate Dryer. 1. What it s meant for?
STR-600 Plate Dryer 1. What it s meant for? Device is meant for water damage drying on local wetted areas. The device suits best for different stone type structures, such as concrete, brick structures
More informationFestoon 715 P PUR cable for flexible application in festoon systems
CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P 07150162:
More informationHIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)
Cable Specification Category 5e CMP HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP) This cable specification complies with the electrical transmission
More informationTwo different types of cables are used in primary airfield lighting circuits: - unshielded cables and - shielded cables
Two different types of cables are used in primary airfield lighting circuits: - unshielded cables and - shielded cables Classically both cables have a single AWG 8 copper conductor or a cross section of
More informationMarineTuff Offshore and Marine Cable Solutions
Offshore and Marine Cable Solutions Belden offers the industry s largest selection of industrial cables for offshore and marine certified applications Whether you are handling oil, natural gas or petrochemicals,
More informationElectric Heat Tracing INSTALLATION PROCEDURES
INSTALLATION PROCEDURES The following installation procedures are suggested guidelines for the installation of a Thermon electric heat tracing system 1. Individuals installing these products are responsible
More informationBUS 1010F Cavo per posa fissa (INTERBUS Remote Bus, 2-wire) INTERBUS cable for fixed installation
SPECIAL CABLES BUS 00F Cavo per posa fissa (INTERBUS Remote Bus, -wire) INTERBUS cable for fixed installation UNIKA BUS 00F c us AWM style 79 80 C 000V FT- Conduttore Conductor Isolamento ed identificazione
More informationProtection Systems. A UTC Fire & Security Company F-73-01. Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS
Effective: May 2007 AlarmLine TM R Protection Systems Linear Heat Detector A UTC Fire & Security Company F-73-01 FEATURES Integrating Type Linear Heat Detector Analog Sensing Field Adjustable Alarm Set
More informationTable 29-1: UL-Marking at Cables & Wires and its intended use
ÖLFLEX Table 29-1: UL-Marking at Cables & Wires and its intended use SILVYN SKINTOP EPIC or (UL) UL Listing Mark for listed cables & wires UL Listed Cables and Wires covered by this category are intended
More informationLEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m
FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2
More informationPresenters Brett Weiss, Gabe Martinez, Brian Kroeger.
1 Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. Topics to be covered: Cable identification Purpose of the various cable types Installation techniques Building Infrastructure Overview of networking
More informationUnit 4: Electricity (Part 2)
Unit 4: Electricity (Part 2) Learning Outcomes Students should be able to: 1. Explain what is meant by power and state its units 2. Discuss the importance of reducing electrical energy wastage 3. State
More informationYour 2 nd best friend
Your 2 nd best friend Hunting cartridges NATURAL 2 Your 2 nd best friend NATURAL FATTE DA CACCIATORI PER I CACCIATORI. La qualità della cartuccia in un azione venatoria è l elemento più importante che
More informationDESCRIZIONE DEI MATERIALI MATERIAL INFORMATION
DESCRIZIONE DEI MATERIALI MATERIAL INFORMATION Ottima resa elastica, resistenza all usura, al taglio e alla lacerazione, buon allungamento alla rottura. Temperatura di impiego: -40 C +100 C. Durezza 45
More informationThe Instrumentation Cable Experts
1 The Instrumentation Cable Experts Facilities Head office & factory 1300 Industrial Boulevard Mt Pleasant, Texas 75455, USA www.dekoroncable.com Stocking Centres USA Mt Pleasant and Houston Singapore
More informationElectrical Resistance Resistance (R)
Electrical Resistance Resistance (R) Any device in a circuit which converts electrical energy into some other form impedes the current. The device which converts electrical energy to heat energy is termed
More informationWire types and sizes
Wire types and sizes This worksheet and all related files are licensed under the Creative Commons Attribution License, version 1.0. To view a copy of this license, visit http://creativecommons.org/licenses/by/1.0/,
More informationElectrical Safety Guidelines FOR THE UNIVERSITY COMMUNITY. Bureau de la gestion du risque, de l environnement et de la santé-sécurité au travail
Bureau de la gestion du risque, de l environnement et de la santé-sécurité au travail Office of Risk Management, Environmental Health and Safety Electrical Safety Guidelines FOR THE UNIVERSITY COMMUNITY
More informationAWG: Cat5e: Cat6: Cat6A:
Some of the terms used in the cable business can be vexing to even the most seasoned folks in the industry. If any of this terminology has ever made you scratch your head, you are certainly not alone.
More informationCable Tray Selection-
Cable Selection- For allowable cable types see the Appendix page A-9. The following guidelines are based on the 2002 National Electrical Code, Article 392. I) Number of Multiconductor Cables rated 2000
More informationTIPS ON ENERGY SAVING
TIPS ON ENERGY SAVING IN HOME APPLIANCES AND ELECTRICITY SAFETY The Domestic Sector accounts for 30% of total energy consumption in the country. There is a tremendous scope to conserve energy by adopting
More informationSuper-Flex Traveling Cable Type ETT/300V
Cable and Super-Flex Traveling Cable Type ETT/300V Jute center - UL listed, CSA certified, NEC/CEC compliant - Power and signal conductors Part Product Number/Size Max. Hang Length Cable Nom. OD Cable
More informationCIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*
Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Available in Standard and Arctic Grade Jackets n Highly
More informationExtension Cord Safety Policy
NATIONAL HIGH MAGNETIC FIELD LABORATORY Operated by Florida State University, University of Florida, Los Alamos National Laboratory Florida State University, 1800 East Paul Dirac Drive, Tallahassee, Florida
More informationPart 2. Overview. Risk management. Workplace health and safety legislation. How should asbestos exposure be managed? Identifying asbestos hazards
Part 2. Overview Risk management Workplace health and safety legislation How should asbestos exposure be managed? identify hazards assess risk decide on control measures implement control measures monitor
More informationIndustrial Ethernet The Perfect Cable for an Imperfect Environment
1 Industrial Ethernet The Perfect Cable for an Imperfect Environment Written by: David Fausz, Engineer, Communications Products TABLE OF CONTENTS BACKGROUND 1 APPLICATIONS AND 2 ELECTRICAL PERFORMANCE
More informationEast Central College 14434.03 HANSEN HALL LEVEL 300/400 RENOVATIONS PACKAGE
SECTION 260519 - BUILDING WIRE AND CABLE PART 1 - GENERAL 1.1 WORK INCLUDES A. Base and Alternate Bids: 1. Contractor Provide: a. Building wire and cable as shown on drawings or specified including feeders,
More informationDirect Attach Cable with Micro Coaxial Wire for Data Center
FEATURED TOPIC Direct Attach Cable with Micro Coaxial Wire for Data Center Yasuhiro MAEDA*, Kensaku SHIMADA, Yuki ISOYA, Tatsunori HAYASHISHITA and Michiko HARUMOTO ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
More informationNEC 2014 Code Changes
NEC 2014 Code Changes Articles 400-408.55 CHANGES FROM 2011 TO 2014 CODE ARE IN RED Chapter 4 Equipment for General Use ARTICLE 400 Flexible Cords and Cables 400.4 Types Flexible cords and flexible cables
More informationDIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION
DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit
More informationSECTION 18370 SIGNAL WIRE AND CABLE
SECTION 18370 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for all cable and wire required for signal and signal power system wiring to wayside shelters, junction boxes, and factory
More informationROSA ANTICO series MRK-010-0174
MRK-010-0174 ROSA ANTICO series TEST DI INVECCHIAMENTO ACCELERATO: Invecchiamento accelerato Tutti i campioni vengono sottoposti all irraggiamento di lampade allo xenon ed a cicli umido/secco mediante
More informationCABLE 101. The Basics of Wire & Cable. Copyright 2007, Belden Inc.
CABLE 101 The Basics of Wire & Cable Copyright 2007, Belden Inc. KEY TERMS Insulations Jacket Capacitance Attenuation Velocity of propagation Dielectric strength Dielectric constant Working voltage Elongation
More information2900 & 3000 Series Commercial Duty Reels 4000 Series Industrial Duty Reels 5000-7000 Series Industrial Duty Reels 8000 Series Hazardous Location
2900 & 3000 Series Commercial Duty Reels 4000 Series Industrial Duty Reels 5000-7000 Series Industrial Duty Reels 8000 Series Hazardous Location Reels SDR Series Grounding Reels Radio Controlled Specialty
More informationBare copper complying with CEI EN 60228 (CEI 20-29) class 1. Foam PE with HDPE skin. Core colours: green and red
SPECIAL CABLES xed installation BUS 0F Conduttore Conductor Isolamento ed cazione anime Insulation and core cation Rame rosso secondo CEI EN 08 (CEI 0-) classe PE espanso con skin in HDPE. Anime colorate
More informationVERRIEGELBARE PRODUKTE
PRODOTTI ANTISFILAMENTO SECURITY CONNECTIONS PRODUKTE PRODUITS SECURITÉ TERMINALI MULTIPLI ANTISFI- LAMENTO 4,8 TERMINALI FEMMINA DIRITTI ANTISFILAMENTO 6,3 SECURITY STRAIGHT RECEPTA- CLES FOR MULTI-WAY
More informationServo Motor & Drive Cables
Servo Motor & Drive Cables Servo-Motor & Drive Cable Contents Servo-SM (Servo-Motor & Feedback Cables to Siemens Specifications) 970 SERVO-SM5-6FX5008-1BD.. UL/CSA/CE SHLD PVC Feedback Cable- Green 971
More informationCables. Accessories. For Force, Torque and Strain Sensors
Accessories Cables For Force, Torque and Strain Sensors Charge mode, high impedance piezoelectric measurement demands highly insulated coaxial cables and connectors to ensure an insulation resistance greater
More informationPhoto: HELUKABEL. Cables according to International Approvals N 1
Photo: HELUKABEL Cables according to International Approvals N 1 Cables according to International Approvals The installation of cables and wires according to overseas standards is getting more and more
More informationThe Quality Connection. LEONI Industrial Solutions Custom-Made Cables
The Quality Connection LEONI Industrial Solutions Custom-Made Cables 2 www.leoni-industrial-solutions.com The LEONI Group is one of the world s largest suppliers of wires, cables and wiring systems, with
More informationAllweather and Rubber Cables
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 21 Owings Mills, MD 211 USA web: http://mdmetric.com ph: ()353130 (00)3130 fx: ()3532 (00)729329 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
More informationWhy FOUNDATION Fieldbus?
Product Bulletin PB 244-R3 Fieldbus Cables Fieldbus Tye A cables rovide installation flexibility in many different environments, including outdoors and where multile or extended cable runs are required.
More informationTop Drive Service Loops. Conventional, Enhanced and Superior Solutions for Drilling Applications
Top Drive Service Loops Conventional, Enhanced and Superior Solutions for Drilling Applications Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective,
More informationCommon Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)
Common Electrical Hazards in the Workplace Including Arc Flash Presented by Ken Cohen, PhD, PE & CIH (Ret.) 1 What s New In February 1972, OSHA incorporated the 1971 edition of the National Fire Protection
More informationINDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23
INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23 GUIDELINES FOR WORKING WITH PORTABLE POWER DISTRIBUTION SYSTEMS AND OTHER ELECTRICAL EQUIPMENT "ADDENDUM C" WORKING WITH 480 VOLT SYSTEMS
More informationUNIVERSITY OF CENTRAL FLORIDA ELECTRICAL SAFETY PROGRAM
UNIVERSITY OF CENTRAL FLORIDA ELECTRICAL SAFETY PROGRAM December 2011 Table of Contents UNIVERSITY OF CENTRAL FLORIDA... 0 Table of Contents... 1 INTRODUCTION... 2 PURPOSE... 2 SCOPE... 3 RESPONSIBILITIES...
More informationELECTRICAL SAFETY: QUALIFIED/NON QUALIFIED
Preparation: Safety Mgr Authority: Dennis Johnston Issuing Dept: Safety Page: Page 1 of 9 Purpose The purpose of the Electrical Safety program is to set forth procedures for the safe use of electrical
More informationContact Hueson Corporation for additional information or details. http://www.huesonwire.com 38 Sutton Street Northbridge, MA 01534 508-234-6372
Hueson Corporation of Northbridge MA, a specialty wire and cable manufacturer has recently introduced a solution to a long term industry challenge in the Trailer Cable Industry. Their solution involves
More informationUniprise Solutions COAX 101. White Paper. www.commscope.com
Uniprise Solutions COAX 101 White Paper www.commscope.com Structured cable systems have very thorough standards for fiber optic and twisted pair installations. The cabling components and installed systems
More informationDigital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.
Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip. Each dielectric configuration has different high-frequency characteristics. All configurations
More informationLifeline Fire Protection Cable Systems. Cables
Lifeline Fire Protection Cable Systems Cables Lifeline - Superior Innovation in Fire Protection Cable Systems Leadership in two-hour cables Introduced by Draka Engineered Specialties, Lifeline two hour
More informationGOLD EFFECT series MRK-010-0131
MRK-010-0131 GOLD EFFECT series TEST DI INVECCHIAMENTO ACCELERATO: Invecchiamento accelerato Tutti i campioni vengono sottoposti all irraggiamento di lampade allo xenon ed a cicli umido/secco mediante
More information100% EMI Emission Containment
100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive
More informationINFORMAZIONI GENERALI / GENERAL INFORMATION
INFORMAZIONI GENERALI / GENERAL INFORMATION LE FLANGE DELLA SOCIETà INTERTUBI SONO FORNITE IN ACCORDO ALLE SEGUENTI NORME: INTERTUBI S FLANGES ARE PROVIDED IN ACCORDING WITH THE FOLLOWINGS STANDARDS Norma
More information450-750 VOLTS - Copper conductor PVC insulated SSA 1320, IEC 60227 & BS 6004 HO 7V - U With Solid Conductor - TYPE 60227 IEC 01. Insulation Thickness
450 50 VOLTS Copper conductor PVC insulated SSA 320, IEC 6022 & BS 6004 HO V U With Solid TYPE 6022 IEC 0 For internal wiring equipment rated voltage up to 000 V AC and up to 50 V to earth. Catalogue Number
More information