Implementing an Energy Management System Using ISO 50001

Size: px
Start display at page:

Download "Implementing an Energy Management System Using ISO 50001"

Transcription

1 Implementing an Energy Management System Using ISO This article will address issues related to sustainability efforts, through energy management as it relates to ISO 50001, Energy Management System (EnMS). To some degree, they are the same thing. Managing energy helps sustain business operations on several levels: reducing operating and overhead costs; lowering you carbon footprint; understanding energy use; energy consuming equipment; and understanding your energy sources. The hardest part of getting started in any process is: knowing where to start. If you have a Quality Management System (QMS) or Environmental Management System (EMS), then your start is easier. First: define and document the scope of your EnMS. The challenge may be determining if your energy scope is the same as your other scopes (QMS or EMS). Will it address the same boundary? Do you have special considerations for your energy scope? Your consumption, intensity, efficiency and use may be different. On the other hand, your boundaries may be well established and, therefore, the same as your other management systems. Clause 4.1, General Requirements, this clause requires a documented scope and to determine how you will meet the requirements of the standard to achieve continual improvement of your energy performance and the EnMS. Clause 4.2 Management Responsibility has two sub-clauses: General; and Roles, Responsibility and Authority. The General sub-clause is similar to QMS and EMS. Top Management has to: Establish the Energy Policy; Appoint a management representative and approve the EnMS team; Provide resources; Identify the scope and boundary of the EnMS; Communicate; Ensure energy objectives and targets are established; Ensure Energy Performance Indicators (EnPIs) are appropriate; Considerations energy performance in long-term planning; and Conduct Management Reviews. The second sub-clause, Roles, Responsibility and Authority, requires top management to appoint a management representative whose duties include: Ensure the EnMS is established, implemented, maintained, and continually improved; Report on the performance of the EnMS and changes in energy performance; Identify person(s) to work with in support of energy management activities; Plan and direct energy management activities to support the energy policy; Define and communicate responsibilities and authorities; Determine criteria and methods needed to ensure the operation and control of the EnMS are effective; and Promote awareness of the energy policy and objectives. Implementing an Energy Management System using ISO by Jerry Skaggs Page 1 of 8

2 The Energy Policy clause (4.3) requires commitment by top management to ensure the Energy Policy: Is appropriate to the nature and scale of energy use and consumption; Includes a commitment to continual improvement in energy performance; Includes a commitment to ensure the availability of information and of necessary resources to achieve objectives and targets; Includes a commitment to comply with applicable legal and other requirements to which they subscribes which relate to energy use, consumption and efficiency; Provides the framework for setting and reviewing energy objectives and targets; Supports the purchase of energy efficient products and services, and design for energy performance improvement; Is documented, communicated, and understood; and Is regularly reviewed, and updated as necessary. ENERGY PLANNING There are six parts to Energy Planning: General; Legal and Other Requirements: Energy Review; Energy Baseline; Energy Performance Indicators; and Objectives, Targets and Action Plans General. The General clause requires you to conduct and document energy planning that includes the clauses mentioned above. Energy planning leads to activities to improve energy performance and involves a review of activities which can affect energy use and consumption, or relate to them in a wider sense. Having brought this data and information together, a range of tools and techniques are available to develop the energy planning outputs Legal and Other Requirements. The Legal and Other Requirements clause is worded similar to EMS. You need to identify and have access to the applicable legal and other requirements to which you subscribe related to energy uses. You need to determine how these requirements apply to energy use, consumption and efficiency and ensure the legal and other requirements to which you subscribe are considered when establishing, implementing and maintaining the EnMS Energy Review. The Energy Review clause outlines the need to develop, record, and maintain an energy review. The methodology and criteria used to develop the energy review shall be documented. To develop the energy review, you need to analyze energy use based on measurement and other data, to include: Identifying current energy sources; Evaluating past and present energy use and consumption; and Estimating future energy use and consumption. Based on the energy use analysis, identify the areas of significant energy use and consumption to: Identify the facilities, equipment, systems, processes and personnel working for or on your behalf that significantly affect energy use and consumption; Identify other relevant variables affecting significant energy uses; Determine the current performance of facilities, equipment, systems, and processes related to identified significant energy uses; and Estimate future energy use and consumption. Implementing an Energy Management System using ISO by Jerry Skaggs Page 2 of 8

3 Identify, prioritize, and record opportunities for improving energy performance, including, where applicable, potential energy sources, use of renewables, or alternative energy sources. The energy review needs to be updated at defined intervals and in response to major changes in facilities, equipment, systems, or processes Energy Baseline. The Energy Baseline clause, requires an energy baseline be established using the information in the initial energy review considering a data period suitable to the energy use. Changes in energy performance need to be measured against the energy baseline. Adjustments to the baseline shall be made when: Energy Performance Indicators no longer reflect energy use; There have been major changes to the process, operational patterns, or energy systems; or According to a predetermined method. This needs to be maintained and recorded Energy Performance Indicators. The Energy Performance Indicators (EnPIs) clause states you need to identify EnPIs appropriate for monitoring and measuring energy performance. The methodology for determining and updating the EnPIs shall be recorded and regularly reviewed. EnPIs shall be reviewed and compared to the energy baseline on a regular basis Objectives, Targets and Action Plans. The last planning clause, Objectives, Targets and Action Plans clause, is again much like the EMS standard, where you need to establish, implement and maintain documented energy objectives and targets within the organization. Time frames need to be established for achievement of the objectives and targets. The objectives and targets need to be consistent with the energy policy. Targets shall be consistent with the objectives. When establishing and reviewing objectives and targets, you need to take into account: Legal and other requirements, Significant energy uses, and opportunities to improve energy performance as identified in the energy review; Financial, operational and business conditions Technological options; and The views of interested parties. Implementing an Energy Management System using ISO by Jerry Skaggs Page 3 of 8

4 You need to establish, implement, and maintain energy management action plans for achieving your objectives and targets. The energy management action plans need to include: Designation of responsibility; The means and time frame by which individual targets are to be achieved; A statement of the method by which an improvement in energy performance shall be verified; and A statement of the method of verifying the results of the action plan. The energy management action plans need to be documented, and updated at defined intervals. As you can see, there are a lot of synergies that can be used from existing quality and environmental systems. IMPLEMENTATION AND OPERATION This section of the standard has seven parts: General; Competence, Training and Awareness; Communication; Documentation; Operational Control; Design; and Procurement of Energy Services, Products and Equipment. These sections are closely related to the QMS and EMS requirements General. The General clause simply states that an organization needs to use the action plans and other outputs resulting from the planning process for implementation and operation Competence, Training and Awareness. The Competence, Training and Awareness clause is similar to EMS. This applies to employees and those working on an organization s behalf with regard to your significant energy uses. Training needs must be identified. Then, training or some other action is taken to meet those needs. Records of these activities must also be maintained. In addition, employees and those working on the organization s behalf need to be made aware of the following: Importance of conformity to the energy policy, procedures and requirements of the EnMS; How they help or are involved in achieving these requirements; Benefits of improved energy performance; and Impact (actual or potential) with respect to energy use and consumption of their activities and behavior contribute to the achievement of energy objectives and targets, potential consequences of departure from specified procedures Communication. The Communication clause is similar to what is found in an EMS. You need to communicate internally with regard to its energy performance and EnMS, as appropriate. You need to establish and implement a process by which any person working for, or on behalf of, the organization can make comments or suggest improvements to the EnMS. You decide whether to communicate externally about your energy policy, EnMS and energy performance, and shall document your decision. If the decision is to communicate externally, you need to establish and implement a method for this external communication Documentation. The Documentation clause is closely related to QMS and EMS. The clause has two sub-clauses, related to Documentation Requirements and Control of Documents Documentation Requirements. You need to establish, implement and maintain information, in paper, electronic or any other medium, to describe the core elements of the EnMS and their interaction. The EnMS documentation includes: Scope and boundaries of the EnMS; Implementing an Energy Management System using ISO by Jerry Skaggs Page 4 of 8

5 Energy Policy; Energy objectives, targets, and action plans; Documents, including records, required by the standard; and Other documents determined by the organization to be necessary. The degree of documentation can vary for different organizations for the following reasons: The scale of the organization and type of activities; Complexity of the processes and their interactions; and Competence of personnel Control of Documents. Documents required by the standard and your EnMS need to be controlled, including technical documentation where appropriate. You need to establish, implement and maintain procedure(s) to: Approve documents for adequacy prior to issue; Periodically reviewed and updated as necessary; Ensure that changes and the current revision status of documents are identified; Ensure that relevant versions of applicable documents are available at points of use; Ensure that documents remain legible and readily identifiable; Ensure documents of external origin necessary for the planning and operation of the EnMS are identified and their distribution controlled; and Prevent the unintended use of obsolete documents, and suitably identify those to be retained for any purpose Operational Control. The Operational Control clause closely resembles the EMS Operational Control (4.4.6) requirement. You need to plan operations associated with their significant energy uses to be consistent with their Energy Policy, Objectives, Targets and Action Plans. This must be carried out under specified conditions which are: Establish and set criteria for effective operation and maintenance of significant energy uses or where the absence could lead to a significant deviation from effective energy performance; Operate and maintain facilities, processes, systems and equipment in accordance with operational criteria; and Appropriate communication of operational controls to persons working for or on your behalf. As noted, these requirements are very similar to and easily integrated with an existing EMS. There is a note: When planning for contingency or emergency situations or potential disasters, including procuring equipment, you may choose to include energy performance in determining how it will react to these situations. As the EnMS standard has no Emergency Preparedness and Response clause, there is a need not to forget and plan for contingencies Design. The Design clause is similar to the QMS requirements (7.3, Design and Development). In this case, you need to consider energy performance improvement opportunities and operational control in the design of new, modified and renovated facilities, equipment, systems and processes that can have a significant impact on its energy performance. The results of the energy performance evaluation shall be incorporated where appropriate into the specification, design and procurement activities of the relevant project(s) and the results of the design activity shall be recorded. Implementing an Energy Management System using ISO by Jerry Skaggs Page 5 of 8

6 4.5.7 Procurement of Energy Services, Products and Equipment. This clause requires that as you move toward increased efficiency in energy performance, the design inputs noted above become the outputs in the purchase of equipment, other products and services. When procuring energy services, products and equipment that have, or can have, an impact on significant energy use, you need to inform suppliers that procurement is partly evaluated on the basis of energy performance. You need to establish and implement the criteria for assessing energy use, consumption and efficiency over the planned or expected operating lifetime when procuring energy using products, equipment and services which are expected to have a significant impact on the organization's energy performance. You need to define and document energy purchasing specifications, as applicable, for effective energy use. A Life Cycle Analysis may become one of the defining selection criteria tools. CHECKING This is the set of clauses where performance is verified and the system s checks and balances are implemented. It has five clauses: Monitoring, measurement and analysis; Evaluation of compliance with legal and other requirements; Internal audit of the EnMS; Noncomformities, correction, corrective and preventive action; and Control of records Monitoring, Measurement and Analysis. This clause is much like all other ISO management system standards, organizations need to make sure key characteristics of its operations that determine energy performance are monitored, measured and analyzed at planned intervals. Key characteristics minimally include: outputs of the energy review; significant energy uses, with its relationship between use and consumption; Energy Performance Indicators (EnPIs); and effectiveness in achieving objectives and targets. In addition, the results from monitoring and measurement need to be recorded. A defined and periodic review of measurement needs is required. Equipment used in monitoring and measuring data must be accurate and repeatable, with appropriate calibration records. An investigation and response to significant deviations in energy performance, with results, need to be maintained Evaluation of Legal and Other Compliance. This clause has the same basis requirements as the EMS. At planned intervals, organizations must evaluate compliance with legal and other requirements to which they subscribe that are relevant to their energy use, against records of previous evaluations Internal Audit of the EnMS. You need to conduct internal audits to make sure the EnMS conforms to their arrangements, and that the standard and is effectively implemented and maintained. The audit plan and schedule is developed considering the status and importance of the processes and areas to be audited as well as the results of previous audits. The selection of auditors Implementing an Energy Management System using ISO by Jerry Skaggs Page 6 of 8

7 and the conduct during audits need to ensure objectivity and the impartiality of the audit process. Records of the audit results need to be maintained and results reported to top management Nonconformities, Correction, Corrective, and Preventive Action. You need to make sure they have procedure(s) for dealing with actual and potential nonconformities and for taking corrective and preventive actions. The procedures shall define requirements for: Reviewing nonconformities or potential nonconformities and determining their causes; Evaluating the need for action to ensure that nonconformities do not occur (preventive) and/or reoccur (corrective); Determining and implementing the appropriate action needed; Maintaining records of corrective and preventive actions; and Reviewing the effectiveness of the corrective or preventive action taken. Corrective and preventive actions need to be appropriate to the magnitude of the actual or potential problems, as well as, the energy consequences encountered. Any necessary changes are then made to the EnMS documentation Control of Records. You need to maintain records as necessary to demonstrate conformity to the Standard, including energy performance results achieved. You will need to define and implement controls for the identification, retrieval and retention of records. Records need to remain legible, identifiable and traceable to the relevant activity, product or service. MANAGEMENT REVIEW 4.7 Management Review. At planned intervals top management needs to review the EnMS to ensure its continuing suitability, adequacy, and effectiveness, with records of management review maintained Input to Management Review. Inputs to the management review need to include: Follow-up actions from previous management reviews; Review of the energy policy; Review of energy performance and related EnPIs; Evaluation of legal compliance and changes in legal and other requirements to which you subscribe; Extent to which the energy objectives and targets have been met; EnMS audit results; the status of corrective and preventive actions; Projected energy performance for the following period, as appropriate; and Recommendations for improvement Output from Management Review. Outputs from the management review need to include any decisions or actions related to: Changes in the energy performance of the organization; Changes to the energy policy; Changes to the EnPIs; Changes to objectives, targets or other elements of the EnMS, consistent with your commitment to continual improvement; and Allocation of resources. Implementing an Energy Management System using ISO by Jerry Skaggs Page 7 of 8

8 For those with an active ISO 14001, ISO 9001, or other ISO management system, these requirements should be familiar. The inclusion of energy activities to an existing system, can make the implementation of an EnMS easier, as you have the existing platforms and understanding of the common elements, such as Training, Control of Documents and Records, etc. SUMMARY The implementation of an EnMS is a cost savings / cost avoidance process, driven by requirements to: Demonstrate continual energy efficiency; Formalize processes and procedures to identify energy use and consumption, including those determined to be significant; Develop a baseline, used to demonstrate energy efficiency; Develop objectives (goals), with ancillary targets (to what degree do you want to achieve the goal) and action plans (methods and responsibilities define to meet the objectives and targets); Implement processes to train employees, communicate, control documents and records, operational control, design and procurement; Verify the processes are effective and implement processes to make corrections for potential and actual issues; and Involve management in the overall determination of the EnMS implementation. Jerry Skaggs, P.E., Environmental, Health, Safety and Energy Product Manager *** If you would like to contact us with energy system related questions, comments, concerns, request a quote please contact your local DQS UL office. Implementing an Energy Management System using ISO by Jerry Skaggs Page 8 of 8