Reducing the Backup Window With Sun StorEdge Instant Image Software

Size: px
Start display at page:

Download "Reducing the Backup Window With Sun StorEdge Instant Image Software"

Transcription

1 Reducing the Backup Window With Sun StorEdge Instant Image Software Selim Daoud, Sun Professional Services, Switzerland Sun BluePrints OnLine July Sun Microsystems, Inc Network Circle Santa Clara, CA U.S.A Part No Revision 1.0, 7/15/02 Edition: July 2002

2 Copyright 2002 Sun Microsystems, Inc. 901 San Antonio Road, Palo Alto, California U.S.A. All rights reserved. This product or document is protected by copyright and distributed under licenses restricting its use, copying, distribution, and decompilation. No part of this product or document may be reproduced in any form by any means without prior written authorization of Sun and its licensors, if any. Third-party software, including font technology, is copyrighted and licensed from Sun suppliers. Parts of the product may be derived from Berkeley BSD systems, licensed from the University of California. UNIX is a registered trademark in the United States and other countries, exclusively licensed through X/Open Company, Ltd. Sun, Sun Microsystems, the Sun logo, Sun BluePrints, Sun Solstice Backup, Sun StorEdge, and Solaris are trademarks or registered trademarks of Sun Microsystems, Inc. in the United States and other countries. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. in the US and other countries. Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems, Inc. The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems, Inc. for its users and licensees. Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry. Sun holds a non-exclusive license from Xerox to the Xerox Graphical User Interface, which license also covers Sun s licensees who implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements. RESTRICTED RIGHTS: Use, duplication, or disclosure by the U.S. Government is subject to restrictions of FAR (g)(2)(6/87) and FAR (6/87), or DFAR (b)(6/95) and DFAR (a). DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID. Copyright 2002 Sun Microsystems, Inc., 901 San Antonio Road, Palo Alto, Californie Etats-Unis. Tous droits réservés. Ce produit ou document est protégé par un copyright et distribué avec des licences qui en restreignent l utilisation, la copie, la distribution, et la décompilation. Aucune partie de ce produit ou document ne peut être reproduite sous aucune forme, par quelque moyen que ce soit, sans l autorisation préalable et écrite de Sun et de ses bailleurs de licence, s il y en a. Le logiciel détenu par des tiers, et qui comprend la technologie relative aux polices de caractères, est protégé par un copyright et licencié par des fournisseurs de Sun. Des parties de ce produit pourront être dérivées des systèmes Berkeley BSD licenciés par l Université de Californie. UNIX est une marque enregistree aux Etats-Unis et dans d autres pays et licenciée exclusivement par X/Open Company Ltd. Sun, Sun Microsystems, le logo Sun, Sun BluePrints, Sun Solstice Backup, Sun StorEdge, et Solaris sont des marques de fabrique ou des marques déposées, ou marques de service, de Sun Microsystems, Inc. aux Etats-Unis et dans d autres pays. Toutes les marques SPARC sont utilisées sous licence et sont des marques de fabrique ou des marques déposées de SPARC International, Inc. aux Etats-Unis et dans d autres pays. Les produits portant les marques SPARC sont basés sur une architecture développée par Sun Microsystems, Inc. L interface d utilisation graphique OPEN LOOK et Sun a été développée par Sun Microsystems, Inc. pour ses utilisateurs et licenciés. Sun reconnaît les efforts de pionniers de Xerox pour la recherche et le développement du concept des interfaces d utilisation visuelle ou graphique pour l industrie de l informatique. Sun détient une licence non exclusive de Xerox sur l interface d utilisation graphique Xerox, cette licence couvrant également les licenciés de Sun qui mettent en place l interface d utilisation graphique OPEN LOOK et qui en outre se conforment aux licences écrites de Sun. CETTE PUBLICATION EST FOURNIE "EN L ETAT" ET AUCUNE GARANTIE, EXPRESSE OU IMPLICITE, N EST ACCORDEE, Y COMPRIS DES GARANTIES CONCERNANT LA VALEUR MARCHANDE, L APTITUDE DE LA PUBLICATION A REPONDRE A UNE UTILISATION PARTICULIERE, OU LE FAIT QU ELLE NE SOIT PAS CONTREFAISANTE DE PRODUIT DE TIERS. CE DENI DE GARANTIE NE S APPLIQUERAIT PAS, DANS LA MESURE OU IL SERAIT TENU JURIDIQUEMENT NUL ET NON AVENU. Please Recycle

3 Reducing the Backup Window With Sun StorEdge Instant Image Software This article discusses the advantages and methods of using a point-in-time (PIT) type of backup system versus a more traditional backup approach that requires extended downtime. This article is for anyone interested in reducing the backup window (improving the uptime of important applications) while backing up a system that is nearly online. The process described here is called nearly online because you must take into consideration that to create a consistent snapshot of a file system, you must take the system offline to perform the following procedures: Quiesce I/O on the volume. Make sure the applications and data associated with this volume are in a good state (Oracle software must be in backup mode, file systems must be synchronized with utilities like fsck, and so on). Postpone all write operations until the snapshot is complete. While the backup techniques described in this article are not focused on specific versions of backup software or hardware, this article uses the following products to provide realistic examples: Sun Solstice Backup software Sun s OEM version of Legato s Networker software Sun StorEdge Instant Image software Sun s software snapshot product Almost any supported version of these two products can be integrated into your networked computing environment to gain the advantages of reducing the backup window and backing up a nearly online system. 1

4 Why Create a Snapshot? Creating a snapshot of a volume (file system or raw partition) has several advantages: You obtain a PIT image of the data so all data is backed up at the same point-in-time, whatever the size of the master volume. The snapshot relieves the original volume (master volume) from excessive I/O during the backup. Note I/O is only relieved on the master volume when the snapshot is an independent snapshot as opposed to a dependent snapshot (also referred to as a copy-on-write). When performing a read I/O on a dependent snapshot, unmodified blocks are read from the master volume and modified blocks are read from the shadow volume. By contrast, read I/O from independent snapshots is performed entirely from the shadow volume, relieving the I/O on the master volume. The latter point is true in the case where the snapshot is a full copy (independent snapshot) of a volume. As a consequence, a volume that has been copied can be made available to the original application. This has the following advantages: The window to backup this volume is very small. You can obtain several backups during the day. There is minimum disruption on the master volume. A copy of the primary volume is available for special applications (testing, data warehousing, and so on). 2 Reducing the Backup Window With Sun StorEdge Instant Image Software July 2002

5 Comparison To appreciate the benefits of a PIT backup system, consider the comparison between a PIT backup and a non-pit backup. Traditional Backup In a traditional non-pit file system backup, the backup process works schematically as shown in the following figure. Client system 1 2 /export Master volume Backup server FIGURE 1 Non-PIT Backup 1. The backup server contacts the client, and arguments are passed defining what to save. 2. The client daemon selects all the files, and transfers them back to the server. Why Create a Snapshot? 3

6 PIT Backup When using the snapshot technology for a PIT backup, the backup process works schematically as shown in the following figure. Client system 1 3 /mnt/ snapshot Snapshot volume /export 2 Master volume Backup server FIGURE 2 PIT Backup 1. The backup server contacts the client, and arguments are passed defining what to save. 2. The client creates the snapshot image (quick update). 3. The client daemon selects all the files on the snapshot volume and transfers them back to the server. Notice that there is an additional step consisting of creating the snapshot volume. What happens is, in fact, a quick update because only modified parts (disk blocks) of the master volume are updated. Therefore, the creation of the snapshot is very quick. 4 Reducing the Backup Window With Sun StorEdge Instant Image Software July 2002

7 Results The following two graphs illustrate the I/O measurements that occur during the two types of backups. In the first graph, the backup is performed without an Instant Image snapshot. The master volume experiences a sustained high level of I/O activity. The second graph reflects the I/O measurements while performing a PIT backup using a snapshot with Instant Image software. You can observe that in terms of I/O, there is a load on the master volume at the beginning of the backup, but the duration is short when compared to the other I/O graph. This short period of master volume activity corresponds to the quick update phase of the backup. Following this, all the I/O is diverted to the shadow volume, relieving the master volume Backup without Instant Image Combined I/O (KB/s) Master Vo 0 FIGURE 3 Master volume Backup I/O Statistics Without Instant Image Software Combined Kb/s Master Volum Shadow Volu 0 Master volume Shadow volume FIGURE 4 Backup I/O Statistics With Instant Image Software Why Create a Snapshot? 5

8 Creating a Snapshot Creating a snapshot of a master volume with Instant Image software (and generally with any PIT software) involves three components: Master volume Snapshot volume (also called the shadow volume) Bitmap volume (a raw partition) To create an independent snapshot (a full copy, for example), the size of the master volume and the shadow volume are identical. The bitmap volume is much smaller and is equal to: Bitmap Size = 8KB per GB + 24KB The examples in this article use the following parameters: Volume Device Capacity Mount Point Master volume /dev/rdsk/c0t0d0s6 7GB /export Shadow volume /dev/rdsk/c0t11d0s6 7GB /mnt/snapshot Bitmap volume /dev/rdsk/d0t11d0s0 80 KB II Group name Solstice Backup Group name BACKUP Default Pre-Processing Script A pre-processing script is created on the client, and initiated by the backup server. This script prepares the snapshot just before the backup operation, and consists of the following steps: 1. Synchronizing the master volume. 2. Locking the master volume against any modification. 3. Initiating the update. 4. Unlocking the master volume. 5. Mounting the snapshot image. 6 Reducing the Backup Window With Sun StorEdge Instant Image Software July 2002

9 The following code sample is an example of a pre-processing script. #!/bin/sh # need to explicit binary path when running pres/post script PATH=/sbin:/usr/local/bin:/usr/local/sbin:/usr/bin:/usr/sbin:/ usr/opt/sunwesm/sbin export PATH # definition of volumes used in II SHADOW_RAW=/dev/rdsk/c0t11d0s6 SHADOW=/dev/dsk/c0t11d0s6 PRIMARY_MNT=/export SHADOW_MNT=/mnt/snapshot II_GROUP=BACKUP # we re-direct output in a logfile exec >> /nsr/logs/snapshot.log 2>&1 # we lock the Master volumes so no I/O take place during "Quick Update" echo "Quick update started" lockfs -f -w $PRIMARY_MNT iiadm -g $II_GROUP -u s if [! "$?" = 0 ] ; then echo "failed to update shadow volume" exit 1 fi echo "Update finished." # we wait for Instant Image to finish its operations iiadm -g $II_GROUP -w # Master Volume can be reactivated and ready for normal operations lockfs -u $PRIMARY_MNT # when doing PIT of a mounted volume, fsck must be executed on snapshot fsck -y $SHADOW # we mount the snapshot volume, ready to be backed up mount $SHADOW $SHADOW_MNT echo "Pre-Script finished" Creating a Snapshot 7

10 Post-Processing Script A post-processing script is also created so that normal operations can continue when the snapshot is complete. The post-processing script is much simpler with one purpose, to unmount the shadow volume. The following code sample is an example of a post-processing script. #!/bin/sh # need to explicit binary path when running pres/post script PATH=/sbin:/usr/local/bin:/usr/local/sbin:/usr/bin:/usr/sbin:/ usr/opt/sunwesm/sbin export PATH SHADOW_MNT=/mnt/snapshot II_GROUP=BACKUP # we re-direct output in a logfile exec >> /nsr/logs/snapshot.log 2>&1 echo " " echo "Unmounting snapshot volume ($SHADOW_MNT)..." echo " " umount $SHADOW_MNT echo "Post-Script finished." 8 Reducing the Backup Window With Sun StorEdge Instant Image Software July 2002

11 Putting Everything Together 1. Configure Instant Image software. In this example, Instant Image software is activated using the following command: # iiadm -g BACKUP -e ind /dev/rdsk/c0t0d0s6 /dev/rdsk/c0t11d0s6 /dev/rdsk/c0t11d0s0 2. Create the pre-processing and post-processing scripts on the client. If you are using Solstice Backup software, the two scripts must be placed in the /nsr/res directory, along with a file called SBU_Group.res. The SBU_Group.res file defines the pre- and post-processing scripts. In our example, the SBU_Group.res file contains the following Solstice Backup software parameters: # cat Default.res type: savepnpc; precmd: /nsr/res/start.snapshot; pstcomd: /nsr/res/stop.snapshot; timeout: 12:00pm ; Putting Everything Together 9

12 3. Configure Solstice Backup software to activate the scripts. For each specific client, in the corresponding Solstice Backup software group, modify the definition of this client so that the parameter Backup Command displays savepnpc, as shown in the following figure. FIGURE 5 Modified Backup Command in the Sun Solstice Backup Client Window 10 Reducing the Backup Window With Sun StorEdge Instant Image Software July 2002

13 Conclusion While the examples in this article use Sun StorEdge Instant Image software and Sun Solstice Backup software, it is possible to obtain similar results with other backup tools such as Veritas Netbackup. Veritas Netbackup also includes a snapshot option called FlashBackup. FlashBackup uses a dependent copy (or copy-on-write). Although this feature is an interesting way of obtaining a PIT copy (because it can be created quickly), it does not relieve the I/O on the master volume, and therefore the backup degrades performance of applications using this volume. The PIT method described in this article is particularly applicable if the volume backed up is a UFS type file system. The main reason is that a snapshot is successful if the master volume can be quiesced during creation of the shadow volume. In our examples, we used the command lockfs to achieve this. This is not applicable for raw partitions, however. For raw partitions, other processes must be developed to make sure nothing is written on the volume (unmounting it, stopping all applications using it, and so on). In conclusion, with a small investment in backup planning and configuration, you can implement backup strategies that effectively shorten the backup window, thus improving the availability of important applications such as databases, web servers, and home directories. About the Author Selim Daoud is a recognized leader in data storage and backup technologies for open systems. He obtained an MSc in computer science at the University of Wales (UK), and an MSc in applied mathematics in computing at Toulouse University in France. Over the course of his career in the computer industry, Selim gained valuable experience working with data backup technology, storage system design (mainly RAID implementations), and UNIX systems administration. He managed a support organization (dealing with storage and backup technology) in London, served as a consultant specializing in backup systems in Paris, and was in charge of multiple migrations of backup systems and storage deployment for the European Organization for Nuclear Research (CERN) in Geneva, Switzerland. Selim currently holds a project engineering position, specializing in computer storage and backup technology in the Sun Professional Services organization in Switzerland. Conclusion 11

14 Ordering Sun Documents The SunDocs SM program provides more than 250 manuals from Sun Microsystems, Inc. If you live in the United States, Canada, Europe, or Japan, you can purchase documentation sets or individual manuals through this program. Accessing Sun Documentation Online The docs.sun.com web site enables you to access Sun technical documentation online. You can browse the docs.sun.com archive or search for a specific book title or subject. The URL is To reference Sun BluePrints OnLine articles, visit the Sun BluePrints OnLine Web site at: 12 Reducing the Backup Window With Sun StorEdge Instant Image Software July 2002

Sun StorEdge A5000 Installation Guide

Sun StorEdge A5000 Installation Guide Sun StorEdge A5000 Installation Guide for Windows NT Server 4.0 Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 USA 650 960-1300 Fax 650 969-9131 Part No. 805-7273-11 October 1998,

More information

Sun Management Center Change Manager 1.0.1 Release Notes

Sun Management Center Change Manager 1.0.1 Release Notes Sun Management Center Change Manager 1.0.1 Release Notes Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. Part No: 817 0891 10 May 2003 Copyright 2003 Sun Microsystems, Inc. 4150

More information

N1 Grid Service Provisioning System 5.0 User s Guide for the Linux Plug-In

N1 Grid Service Provisioning System 5.0 User s Guide for the Linux Plug-In N1 Grid Service Provisioning System 5.0 User s Guide for the Linux Plug-In Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. Part No: 819 0735 December 2004 Copyright 2004 Sun Microsystems,

More information

Sun StorEdge RAID Manager 6.2.21 Release Notes

Sun StorEdge RAID Manager 6.2.21 Release Notes Sun StorEdge RAID Manager 6.2.21 Release Notes formicrosoftwindowsnt Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 USA 650 960-1300 Fax 650 969-9131 Part No. 805-6890-11 November

More information

LAN-Free Backups Using the Sun StorEdge Instant Image 3.0 Software

LAN-Free Backups Using the Sun StorEdge Instant Image 3.0 Software LAN-Free Backups Using the Sun StorEdge Instant Image 3.0 Software Art Licht, Sun Microsystems, Inc. Sun BluePrints OnLine June 2002 http://www.sun.com/blueprints Sun Microsystems, Inc. 4150 Network Circle

More information

Upgrading the Solaris PC NetLink Software

Upgrading the Solaris PC NetLink Software Upgrading the Solaris PC NetLink Software By Don DeVitt - Enterprise Engineering Sun BluePrints OnLine - January 2000 http://www.sun.com/blueprints Sun Microsystems, Inc. 901 San Antonio Road Palo Alto,

More information

Sun Cluster 2.2 7/00 Data Services Update: Apache Web Server

Sun Cluster 2.2 7/00 Data Services Update: Apache Web Server Sun Cluster 2.2 7/00 Data Services Update: Apache Web Server Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 U.S.A. 650-960-1300 Part No. 806-6121 July 2000, Revision A Copyright 2000

More information

Solaris 10 Documentation README

Solaris 10 Documentation README Solaris 10 Documentation README Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. Part No: 817 0550 10 January 2005 Copyright 2005 Sun Microsystems, Inc. 4150 Network Circle, Santa

More information

Optimizing Solaris Resources Through Load Balancing

Optimizing Solaris Resources Through Load Balancing Optimizing Solaris Resources Through Load Balancing By Tom Bialaski - Enterprise Engineering Sun BluePrints Online - June 1999 http://www.sun.com/blueprints Sun Microsystems, Inc. 901 San Antonio Road

More information

Sun Enterprise Optional Power Sequencer Installation Guide

Sun Enterprise Optional Power Sequencer Installation Guide Sun Enterprise Optional Power Sequencer Installation Guide For the Sun Enterprise 6500/5500 System Cabinet and the Sun Enterprise 68-inch Expansion Cabinet Sun Microsystems, Inc. 901 San Antonio Road Palo

More information

Sun StorEdge Availability Suite Software Point-in-Time Copy Software Maximizing Backup Performance

Sun StorEdge Availability Suite Software Point-in-Time Copy Software Maximizing Backup Performance Sun StorEdge Availability Suite Software Point-in-Time Copy Software Maximizing Backup Performance A Best Practice Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part

More information

Service Level Definitions and Interactions

Service Level Definitions and Interactions Service Level Definitions and Interactions By Adrian Cockcroft - Enterprise Engineering Sun BluePrints OnLine - April 1999 http://www.sun.com/blueprints Sun Microsystems, Inc. 901 San Antonio Road Palo

More information

Scrubbing Disks Using the Solaris Operating Environment Format Program

Scrubbing Disks Using the Solaris Operating Environment Format Program Scrubbing Disks Using the Solaris Operating Environment Format Program By Rob Snevely - Enterprise Technology Center Sun BluePrints OnLine - June 2000 http://www.sun.com/blueprints Sun Microsystems, Inc.

More information

Sun StorEdge T3 Dual Storage Array - Part 1

Sun StorEdge T3 Dual Storage Array - Part 1 Sun StorEdge T3 Dual Storage Array - Part 1 Installation, Planning, and Design By Mark Garner - Enterprise Engineering Sun BluePrints OnLine - February 2001 http://www.sun.com/blueprints Sun Microsystems,

More information

SunFDDI 6.0 on the Sun Enterprise 10000 Server

SunFDDI 6.0 on the Sun Enterprise 10000 Server SunFDDI 6.0 on the Sun Enterprise 10000 Server Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 USA 650 960-1300 Fax 650 969-9131 Part No.: 806-3610-11 November 1999, Revision A Send

More information

Sun StorEdge N8400 Filer Release Notes

Sun StorEdge N8400 Filer Release Notes Sun StorEdge N8400 Filer Release Notes Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303 U.S.A. 650-960-1300 Part No. 806-6888-10 February 2001, Revision A Send comments about this document

More information

Sun Enterprise 420R Server Product Notes

Sun Enterprise 420R Server Product Notes Sun Enterprise 420R Server Product Notes Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 USA 650 960-1300 Fax 650 969-9131 Part No. 806-1082-12 May 2001, Revision A Send comments about

More information

Service Level Agreement in the Data Center

Service Level Agreement in the Data Center Service Level Agreement in the Data Center By Edward Wustenhoff Sun Professional Services Sun BluePrints OnLine - April 2002 http://www.sun.com/blueprints Sun Microsystems, Inc. 4150 Network Circle Santa

More information

Comparing JavaServer Pages Technology and Microsoft Active Server Pages

Comparing JavaServer Pages Technology and Microsoft Active Server Pages Comparing JavaServer Pages Technology and Microsoft Active Server Pages An Analysis of Functionality Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303 1 (800) 786.7638 1.512.434.1511 Copyright

More information

Solaris Bandwidth Manager

Solaris Bandwidth Manager Solaris Bandwidth Manager By Evert Hoogendoorn - Enterprise Engineering Sun BluePrints Online - June 1999 http://www.sun.com/blueprints Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303 USA

More information

Sun Management Center 3.6 Version 5 Add-On Software Release Notes

Sun Management Center 3.6 Version 5 Add-On Software Release Notes Sun Management Center 3.6 Version 5 Add-On Software Release Notes For Sun Fire, Sun Blade, Netra, and Sun Ultra Systems Sun Microsystems, Inc. www.sun.com Part No. 819-7977-10 October 2006, Revision A

More information

Sun StorEdge Instant Image 3.0 and Oracle8i Database Best Practices

Sun StorEdge Instant Image 3.0 and Oracle8i Database Best Practices Sun StorEdge Instant Image 3.0 and Oracle8i Database Best Practices Art Licht Sun BluePrints OnLine August 2002 http://www.sun.com/blueprints Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA

More information

Exploring the iplanet Directory Server NIS Extensions

Exploring the iplanet Directory Server NIS Extensions Exploring the iplanet Directory Server NIS Extensions By Tom Bialaski - Enterprise Engineering Sun BluePrints OnLine - August 2000 http://www.sun.com/blueprints Sun Microsystems, Inc. 901 San Antonio Road

More information

Sun StorEdge Enterprise Backup Software 7.2

Sun StorEdge Enterprise Backup Software 7.2 Sun StorEdge Enterprise Backup Software 7.2 Update Guide Sun Microsystems, Inc. www.sun.com Part No. 819-4089-10 September 2005, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback

More information

Solaris 9 9/05 Installation Roadmap

Solaris 9 9/05 Installation Roadmap Solaris 9 9/05 Installation Roadmap This document is a guide to the DVD-ROM, CD-ROMs, and documents involved in installing the Solaris 9 9/05 software. Unless otherwise specified, this document refers

More information

JumpStart : NIS and sysidcfg

JumpStart : NIS and sysidcfg JumpStart : NIS and sysidcfg By Rob Snevely - Enterprise Technology Center Sun BluePrints OnLine - October 1999 http://www.sun.com/blueprints Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303

More information

Sun Management Center 3.5 Update 1b Release Notes

Sun Management Center 3.5 Update 1b Release Notes Sun Management Center 3.5 Update 1b Release Notes Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. Part No: 819 3054 10 June 2005 Copyright 2005 Sun Microsystems, Inc. 4150 Network

More information

Java Dynamic Management Architecture for Intelligent Networks

Java Dynamic Management Architecture for Intelligent Networks Java Dynamic Management Architecture for Intelligent Networks Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303 1 (800) 786.7638 +1.512.434.1511 Copyright 1998 Sun Microsystems, Inc., 901

More information

Disaster Recovery Requirements Analysis

Disaster Recovery Requirements Analysis Disaster Recovery Requirements Analysis By Stan Stringfellow - Special to Sun BluePrints OnLine Sun BluePrints OnLine - July 2000 http://www.sun.com/blueprints Sun Microsystems, Inc. 901 San Antonio Road

More information

Managing NFS Workloads

Managing NFS Workloads Managing NFS Workloads By Richard McDougall, Adrian Cockcroft and Evert Hoogendoorn - Enterprise Engineering Sun BluePrints OnLine - April 1999 http://www.sun.com/blueprints Sun Microsystems, Inc. 901

More information

Sun TM SNMP Management Agent Release Notes, Version 1.6

Sun TM SNMP Management Agent Release Notes, Version 1.6 Sun TM SNMP Management Agent Release Notes, Version 1.6 Sun Microsystems, Inc. www.sun.com Part No. 820-5966-12 December 2008, Revision A Submit comments about this document by clicking the Feedback[+]

More information

Power Savings in the UltraSPARC T1 Processor

Power Savings in the UltraSPARC T1 Processor Power Savings in the UltraSPARC T1 Processor David Greenhill, Distinguished Engineer Jerome Alabado, Staff Engineer Sun Microsystems Inc. December 2005 Sun Microsystems, Inc. 4150 Network Circle Santa

More information

Sun Ultra TM. 5 and Ultra 10 Product Notes. Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 U.S.A.

Sun Ultra TM. 5 and Ultra 10 Product Notes. Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 U.S.A. Sun Ultra TM 5 and Ultra 10 Product Notes Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 U.S.A. 650-960-1300 Part No. 806-6750-11 November 2000, Revision A Send comments about this

More information

Important Note on New Product Names

Important Note on New Product Names Important Note on New Product Names As part of Sun s new developer product strategy, we have changed the names of our development tools from Sun WorkShop to Forte Developer products. The products, as you

More information

Sun Management Center 3.6 Version 4 Add-On Software Release Notes

Sun Management Center 3.6 Version 4 Add-On Software Release Notes Sun Management Center 3.6 Version 4 Add-On Software Release Notes For Sun Fire, Sun Blade, Netra, and Sun Ultra Systems Sun Microsystems, Inc. www.sun.com Part No. 819-4989-10 July 2006, Revision A Submit

More information

Sun StorEdge Network FC Switch-8 and Switch-16 Release Notes

Sun StorEdge Network FC Switch-8 and Switch-16 Release Notes Sun StorEdge Network FC Switch-8 and Switch-16 Release Notes Sun StorEdge SAN 3.0 Release Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 U.S.A. 650-960-1300 Part No. 816-0842-12 February

More information

HelloWorld SOAP Sample:

HelloWorld SOAP Sample: HelloWorld SOAP Sample: Accessing Stateless Session Enterprise JavaBeans Technology Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303 U.S.A. 650-960-1300 Copyright 2002 Sun Microsystems,

More information

Sun Management Center 3.0 Platform Update 4 Release Notes for Sun Fire 15K/12K Systems

Sun Management Center 3.0 Platform Update 4 Release Notes for Sun Fire 15K/12K Systems Sun Management Center 3.0 Platform Update 4 Release Notes for Sun Fire 15K/12K Systems Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part No. 816-5008-10 April 2002,

More information

Developing a Security Policy

Developing a Security Policy Developing a Security Policy By Joel Weise - SunPS SM Global Security Practice and Charles R. Martin - SunPS Java Centers Sun BluePrints OnLine - December 2001 http://www.sun.com/blueprints Sun Microsystems,

More information

Sun SNMP Management Agent Release Notes, Version 1.5.5

Sun SNMP Management Agent Release Notes, Version 1.5.5 Sun SNMP Management Agent Release Notes, Version 1.5.5 Sun Microsystems, Inc. www.sun.com Part No. 820-0174-15 June 2008, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback

More information

Sun Fire 6800/4810/4800/3800 Systems Software Release Notes

Sun Fire 6800/4810/4800/3800 Systems Software Release Notes Sun Fire 6800/4810/4800/3800 Systems Software Release Notes Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 USA 650 960-1300 Fax 650 969-9131 Part No.: 816-2553-10 (v2) October 2001,

More information

Sun Grid Engine 5.2.3 Release Notes

Sun Grid Engine 5.2.3 Release Notes Sun Grid Engine 5.2.3 Release Notes Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 U.S.A. 650-960-1300 Part No. 816-2082-10 July 2001 For more information, go to http://www.sun.com/gridware

More information

N1 Grid Engine 6 Release Notes

N1 Grid Engine 6 Release Notes N1 Grid Engine 6 Release Notes Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. Part No: 817 5678 10 June 2004 Copyright 2004 Sun Microsystems, Inc. 4150 Network Circle, Santa Clara,

More information

Rapid Recovery Techniques: Exploring the Solaris Software Registry

Rapid Recovery Techniques: Exploring the Solaris Software Registry Rapid Recovery Techniques: Exploring the Solaris Software Registry By Richard Elling - Enterprise Engineering Sun BluePrints OnLine - October 1999 http://www.sun.com/blueprints Sun Microsystems, Inc. 901

More information

Service Level Management in the Data Center

Service Level Management in the Data Center Service Level Management in the Data Center By Edward Wustenhoff Sun Professional Sun BluePrints OnLine - March 2002 http://www.sun.com/blueprints Sun Microsystems, Inc. 4150 Network Circle Santa Clara,

More information

Sun Fire 6800/4810/4800/ 3800 Systems Product Notes

Sun Fire 6800/4810/4800/ 3800 Systems Product Notes Sun Fire 6800/4810/4800/ 3800 Systems Product Notes Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 USA 650 960-1300 Fax 650 969-9131 Part No.: 806-7217-10 March 2001, Revision A Send

More information

Consolidation in the Data Center

Consolidation in the Data Center Consolidation in the Data Center David Hornby, Global Sales Organization Ken Pepple, Enterprise Services Sun BluePrints OnLine September 2002 http://www.sun.com/blueprints Sun Microsystems, Inc. 4150 Network

More information

Rapid Recovery Techniques: Auditing Custom Software Configuration

Rapid Recovery Techniques: Auditing Custom Software Configuration Rapid Recovery Techniques: Auditing Custom Software Configuration By Richard Elling - Enterprise Engineering Sun BluePrints OnLine - February 2000 http://www.sun.com/blueprints Sun Microsystems, Inc. 901

More information

Solaris Resource Manager

Solaris Resource Manager Solaris Resource Manager By Richard McDougall - Enterprise Engineering Sun BluePrints OnLine - April 1999 http://www.sun.com/blueprints Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303 USA

More information

The UltraSPARC T1 Processor - High Bandwidth For Throughput Computing

The UltraSPARC T1 Processor - High Bandwidth For Throughput Computing The UltraSPARC T1 Processor - High Bandwidth For Throughput Computing William Bryg, Distinguished Engineer Jerome Alabado, Staff Engineer Sun Microsystems, Inc. December 2005 Sun Microsystems, Inc. 4150

More information

Sun Fire 15K/12K Dynamic Reconfiguration Installation Guide and Release Notes

Sun Fire 15K/12K Dynamic Reconfiguration Installation Guide and Release Notes Sun Fire 15K/12K Dynamic Reconfiguration Installation Guide and Release Notes Solaris 8 2/02 Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part No. 816-5080-10 April

More information

Sun Fire B10n Content Load Balancing Blade Product Notes

Sun Fire B10n Content Load Balancing Blade Product Notes Sun Fire B10n Content Load Balancing Blade Product Notes Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part No. 817-0628-10 June 2003, Revision A Submit comments

More information

SCSI Sense Key Error Guide

SCSI Sense Key Error Guide SCSI Sense Key Error Guide Sun Microsystems, Inc. www.sun.com Part No. 817-5918-10 February 2004, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback Copyright 2004 Sun

More information

The Solaris Fingerprint Database - A Security Tool for Solaris Operating Environment Files

The Solaris Fingerprint Database - A Security Tool for Solaris Operating Environment Files The Solaris Fingerprint Database - A Security Tool for Solaris Operating Environment Files By Vasanthan Dasan - Support Services Strategy Group, Alex Noordergraaf - Enterprise Engineering, and Lou Ordorica

More information

Start Here. Installation and Documentation Reference. Sun StorEdgeTM 6120 Array

Start Here. Installation and Documentation Reference. Sun StorEdgeTM 6120 Array Start Here Installation and Documentation Reference Sun StorEdgeTM 6120 Array 1 Access the Online Documentation These documents and other related documents are available online at http://www.sun.com/documentation

More information

RAID Controller PCI Card for the Sun Fire V60x and V65x Servers Release Notes

RAID Controller PCI Card for the Sun Fire V60x and V65x Servers Release Notes RAID Controller PCI Card for the Sun Fire V60x and V65x Servers Release Notes CAUTION: Read this document before installing the RAID Controller PCI Card. Failure to use the correct firmware version with

More information

Java Management Extensions SNMP Manager API

Java Management Extensions SNMP Manager API Java Management Extensions SNMP Manager API Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303 U.S.A. 650-960-1300 August 1999, Draft 2.0 Copyright 1999 Sun Microsystems, Inc., 901 San Antonio

More information

Data Center Design Philosophy

Data Center Design Philosophy Data Center Design Philosophy By Rob Snevely - Enterprise Technology Center Sun BluePrints OnLine - January 2002 http://www.sun.com/blueprints Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA

More information

Automating Centralized File Integrity Checks in the Solaris 10 Operating System

Automating Centralized File Integrity Checks in the Solaris 10 Operating System Automating Centralized File Integrity Checks in the Solaris 10 Operating System Glenn Brunette, Client Solutions Sun BluePrints OnLine March 2005 A Sun BluePrints Cookbook http://www.sun.com/blueprints

More information

Sun StorEdge RAID Manager 6.22 User s Guide

Sun StorEdge RAID Manager 6.22 User s Guide Sun StorEdge RAID Manager 6.22 User s Guide Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 USA 650 960-1300 Fax 650 969-9131 Part No. 806-0478-10 September 1999, Revision A Send comments

More information

Sun Microsystems, Inc. 2550 Garcia Avenue Mountain View, CA 94043 415 960-1300 FAX 415 969-9131

Sun Microsystems, Inc. 2550 Garcia Avenue Mountain View, CA 94043 415 960-1300 FAX 415 969-9131 Sun Microsystems, Inc. 2550 Garcia Avenue Mountain View, CA 94043 415 960-1300 FAX 415 969-9131 For U.S. Sales Office locations, call: 800 821-4643 In California: 800 821-4642 Australia: (02) 413 2666

More information

Solaris 9 Installation Roadmap

Solaris 9 Installation Roadmap Solaris 9 Installation Roadmap This document is a guide to the DVD, CDs and documents involved in installing the Solaris 9 software. Unless otherwise specified, this document refers to both DVDs and CDs

More information

Sun Fire 6800/4810/4800/3800 Systems Firmware 5.13.3 Release Notes

Sun Fire 6800/4810/4800/3800 Systems Firmware 5.13.3 Release Notes Sun Fire 6800/4810/4800/3800 Systems Firmware 5.13.3 Release Notes Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part No. 816-7909-10(v2) October 2002, Revision A

More information

Sun StorEdge SAN Foundation Release Notes

Sun StorEdge SAN Foundation Release Notes Sun StorEdge SAN Foundation Release Notes Version 4.1 Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part No. 817-0071-10 October 2002, Revision 01 Send comments about

More information

Trust Modeling for Security Architecture Development

Trust Modeling for Security Architecture Development Trust Modeling for Security Architecture Development Donna Andert, Robin Wakefield, and Joel Weise, Professional Services Security Practice Sun BluePrints OnLine December 2002 http://www.sun.com/blueprints

More information

Brocade SilkWorm 4100 FC Switch Release Notes

Brocade SilkWorm 4100 FC Switch Release Notes Brocade SilkWorm 4100 FC Switch Release Notes For Installation in Sun Storage Area Networks, 4.4.0b Firmware Sun Microsystems, Inc. www.sun.com Part No. 819-1672-10 April 2005, Revision A Submit comments

More information

SunPCi Supporting Highly Available PC Applications with Solaris

SunPCi Supporting Highly Available PC Applications with Solaris SunPCi Supporting Highly Available PC Applications with Solaris By Don DeVitt - Enterprise Engineering Sun BluePrints OnLine - August 1999 http://www.sun.com/blueprints Sun Microsystems, Inc. 901 San Antonio

More information

Netra Data Plane Software Suite 2.0 Update 2 Release Notes

Netra Data Plane Software Suite 2.0 Update 2 Release Notes Netra Data Plane Software Suite 2.0 Update 2 Release Notes Sun Microsystems, Inc. www.sun.com Part No. 820-5213-11 July 2008, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback

More information

Sun StorEdge T3 Dual Storage Array - Part 3 Basic Management. By Mark Garner - Enterprise Engineering Sun BluePrints OnLine - April 2001

Sun StorEdge T3 Dual Storage Array - Part 3 Basic Management. By Mark Garner - Enterprise Engineering Sun BluePrints OnLine - April 2001 Sun StorEdge T3 Dual Storage Array - Part 3 Basic Management By Mark Garner - Enterprise Engineering Sun BluePrints OnLine - April 2001 Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303 USA

More information

Java Technologies for Interactive Television

Java Technologies for Interactive Television Java Technologies for Interactive Television Technical White Paper Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303 1 (800) 786.7638 1.512.434.1511 Copyright 2001 Sun Microsystems, Inc.,

More information

Sun Ray, Smart Cards, and Citrix

Sun Ray, Smart Cards, and Citrix Sun Ray, Smart Cards, and Citrix Enabling Sun Ray Smart Card Pass-through to Citrix Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 May 2004, Version 1.0 Copyright

More information

Solaris Patch Management: Recommended Strategies

Solaris Patch Management: Recommended Strategies Solaris Patch Management: Recommended Strategies A White Paper Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303 USA 650 960-1300 fax 650 969-9131 Part No.: 817-0574-11 Revision 02, October

More information

Sun Remote System Control (RSC) Installation Guide

Sun Remote System Control (RSC) Installation Guide Sun Remote System Control (RSC) Installation Guide Sun Microsystems, Inc. 901 San Antonio Road Palo Alto,CA 94303-4900 U.S.A. 650-960-1300 Part No. 806-3987-10 February 2000, Revision A Send comments about

More information

Sun Fire V480 Server Product Notes

Sun Fire V480 Server Product Notes Sun Fire V480 Server Product Notes Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part No. 816-0905-14 September 2002, Revision A Send comments about this document

More information

Sun StorEdge network FC switch-8 and switch-16 Release Notes

Sun StorEdge network FC switch-8 and switch-16 Release Notes Sun StorEdge network FC switch-8 and switch-16 Release Notes Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 U.S.A. 650-960-1300 Part No. 806-6924-14 February 2001, Revision A Send

More information

Sun N1 Service Provisioning System User s Guide for Linux Plug-In 2.0

Sun N1 Service Provisioning System User s Guide for Linux Plug-In 2.0 Sun N1 Service Provisioning System User s Guide for Linux Plug-In 2.0 Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. Part No: 819 4885 10 April 2006 Copyright 2006 Sun Microsystems,

More information

Sun Fire Midframe Server Best Practices for Administration

Sun Fire Midframe Server Best Practices for Administration Sun Fire Midframe Server Best Practices for Administration By James Hsieh - Customer Problem Resolution (CPR) Engineering - Americas (formerly HES-CTE) Sun BluePrints OnLine - October 2001 http://www.sun.com/blueprints

More information

Java Card Platform Security

Java Card Platform Security Java Card Platform Security Technical White Paper Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303 1 (800) 786.7638 1.512.434.1511 http://java.sun.com/products/javacard Copyright 2001 Sun

More information

A Strategy for Managing Performance

A Strategy for Managing Performance A Strategy for Managing Performance John Brady, Sun Professional Services Sun BluePrints OnLine December 2002 http://www.sun.com/blueprints Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95045

More information

Sun Blade 1500 Workstation Product Notes

Sun Blade 1500 Workstation Product Notes Sun Blade 1500 Workstation Product Notes (Silver) Silver Sun Microsystems, Inc. www.sun.com Part No. 817-5131-13 April 2005, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback

More information

Sun 450 MHz UltraSPARC -II Module Upgrade

Sun 450 MHz UltraSPARC -II Module Upgrade Sun 450 MHz UltraSPARC -II Module Upgrade Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 USA 650 960-1300 Fax 650 969-9131 Part No.: 806-1055-11 Revision A, October 1999 Send comments

More information

Conference Calling Using SunForum 3

Conference Calling Using SunForum 3 SunForum 3.1 Software User s Guide Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 U.S.A. 650-960-1300 Part No. 805-4479-13 September 2000, Revision A Send comments about this document

More information

Sun Fire V20z Server Release Notes

Sun Fire V20z Server Release Notes Sun Fire V20z Server Release Notes Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part No. 817-5252-10 March, 2004 Revison A Submit comments about this document at:

More information

Veritas Storage Foundation 5.0 Software for SPARC

Veritas Storage Foundation 5.0 Software for SPARC Veritas Storage Foundation 5.0 Software for SPARC Release Note Supplement Sun Microsystems, Inc. www.sun.com Part No. 819-7074-10 July 2006 Submit comments about this document at: http://www.sun.com/hwdocs/feedback

More information

Sun Ray Server Software 3 Release Notes

Sun Ray Server Software 3 Release Notes Sun Ray Server Software 3 Release Notes for the Linux Operating System Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Copyright 2004, Sun Microsystems Part No. 817-6813-10

More information

Distributed Application Management using Jini Connection Technology

Distributed Application Management using Jini Connection Technology Distributed Application Management using Jini Connection Technology The Jini Technology Enabled Applications Manager provides a framework, utilizing Jini and JavaSpaces technologies, for selecting and

More information

Solaris Volume Manager Administration Guide

Solaris Volume Manager Administration Guide Solaris Volume Manager Administration Guide Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. Part No: 816 4520 12 May 2006 Copyright 2006 Sun Microsystems, Inc. 4150 Network Circle,

More information

Operations Management Capabilities Model

Operations Management Capabilities Model Operations Capabilities Model Edward Wustenhoff, Sun Global Datacenter Practice, Client Solutions Michael J. Moore, Sun Global Datacenter Practice, Client Solutions Dale H. Avery, Sun Educational Services

More information

Getting StartedWith Sun Java System Application Server 9.1 Update 2

Getting StartedWith Sun Java System Application Server 9.1 Update 2 Getting StartedWith Sun Java System Application Server 9.1 Update 2 Student Guide Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. August 2008 Copyright 2008 Sun Microsystems, Inc.

More information

MIGRATION WHITEPAPER MIGRATING FROM MICROSOFT OFFICE TO OPENOFFICE.ORG OR STAROFFICE 9

MIGRATION WHITEPAPER MIGRATING FROM MICROSOFT OFFICE TO OPENOFFICE.ORG OR STAROFFICE 9 MIGRATION WHITEPAPER MIGRATING FROM MICROSOFT OFFICE TO OPENOFFICE.ORG OR STAROFFICE 9 April, 2009 Copyrights and Trademarks Copyright 2009 Sun Microsystems, Inc. 4150Network Circle, Santa Clara, CA 95054

More information

Sun GlassFish Enterprise Manager SNMP Monitoring 1.0 Installation and Quick Start Guide

Sun GlassFish Enterprise Manager SNMP Monitoring 1.0 Installation and Quick Start Guide Sun GlassFish Enterprise Manager SNMP Monitoring 1.0 Installation and Quick Start Guide Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. Part No: 820 7189 January 2009 Copyright

More information

Netra X4200 M2 Server Site Planning Guide

Netra X4200 M2 Server Site Planning Guide Netra X4200 M2 Server Site Planning Guide Sun Microsystems, Inc. www.sun.com Part No. 820-0069-12 May 2008, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback Copyright

More information

Brocade 5300 Switch Hardware Release Notes

Brocade 5300 Switch Hardware Release Notes Brocade 5300 Switch Hardware Release tes For Installation in a Sun Storage Area Network Sun Microsystems, Inc. www.sun.com Part. 820-4925-10 May 2008, Revision A Submit comments about this document at:

More information

Using Linux mdadm Multipathing with Sun StorEdge Systems

Using Linux mdadm Multipathing with Sun StorEdge Systems Using Linux mdadm Multipathing with Sun StorEdge Systems Sun Microsystems, Inc. www.sun.com Part No. 819-2452-10 April 2005, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback

More information

Brocade 300 Switch Hardware Release Notes

Brocade 300 Switch Hardware Release Notes 300 Switch Hardware Release Notes For Installation in a Sun Storage Area Network Sun Microsystems, Inc. www.sun.com Part No. 820-4923-11 November 2008, Revision A Submit comments about this document at:

More information

Platform Notes: The SunHSI/P Device Driver

Platform Notes: The SunHSI/P Device Driver Platform Notes: The SunHSI/P Device Driver Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 U.S.A Part No.: 806-0447-10 May 1999, Revision A Send comments about this document to: docfeedback@sun.com

More information

Sun Blade 100 and Sun Blade 150 Workstations

Sun Blade 100 and Sun Blade 150 Workstations Sun Blade 100 and Sun Blade 150 Workstations Differences Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part No. 990-1211-10 June 2002, Revision 01 Send comments about

More information

Sun Ultra 80 SCSI Cable Installation Guide

Sun Ultra 80 SCSI Cable Installation Guide Sun Ultra 80 SCSI Cable Installation Guide Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303 U.S.A. 650-960-1300 Part No. 806-4423-10 March 2000, Revision A Send comments about this document

More information

Sharing NFS and Remote File Systems via Solaris PC NetLink Software

Sharing NFS and Remote File Systems via Solaris PC NetLink Software Sharing NFS and Remote File Systems via Solaris PC NetLink Software By Don DeVitt - Enterprise Engineering Sun BluePrints OnLine - November 2000 http://www.sun.com/blueprints Sun Microsystems, Inc. 901

More information

Sun StorEdge FC-100 Long Wave Gigabit Interface Converter Guide

Sun StorEdge FC-100 Long Wave Gigabit Interface Converter Guide Sun StorEdge FC-100 Long Wave Gigabit Interface Converter Guide Caution LW GBIC performance depends upon the correct implementation of a 10 km Single Mode Optical Fiber Cable Plant which complies with

More information