1 Sun Blade(TM) 6000 Modular System Technical Training Jacques Bessoudo Technical Marketing Systems Group Sun Microsystems Inc 1

2 (TM) Sun Blade Modular Systems Extending the Systems Portfolio 2

3 Sun Blade Modular System More Memory More I/O Memory DIMM / CPU I/O Gbps Per Blade More Threads Core Per CPU MORE More Open More Efficiency, More Applications Sun 3 HP IBM Dell

4 Industry's Most Open Blade Platform Easy Integration Into Existing Data Centers. Avoid Vendor Lock-In. Leverage existing open standard technology and ecosystems. No proprietary I/O device or management tool required. Simplify your business. Use N1SM or your existing 3rd party tools. OpenSolaris(TM). OpenSPARC(TM). Transparent Management. Independent Industry Standard I/O. 4

5 Why Sun Blades? CPU Architecture choice Future Proof Modular Architecture Transparent Management Independent I/O High Efficiency Cooling 5 Power Mgmt Mgmt Compute Modular Computing Cooling I/O Storage

6 Continuing To Push The Limit Game Changing Portfolio > Sun Constellation System Ultra-dense Blade Platform Ultra-dense Switching Solution Ultra-dense Storage Solution Software > Eco-Efficient building blocks > Developer Environment and Management Tools SunSMCustomer Ready Architected Systems > HPC Cluster, including Sun Blade Scalable Unit > Visualization System > Scalable Storage Cluster Very large deployments > Tokyo Tech > TACC (under construction) > KISTI (under construction) 6 Delivering Seamless Scalability 1TF 1.7PF Most Open Highest Performing Most Serviceable Fastest Deployment Most Robust Most Reliable Most Available

7 The New Era of HPC Innovations in HPC meet the Commercial world Today HPC customers want more: > Radical Efficiency Performance, Power, > > > > 7 Cooling, Space, Cost Super Scalability Paving the way to Petaflops Open Systems Open Interfaces & Industry Standard Components Industrial Robustness High Availability & Reliability Production Ready Time to Results or Production

8 Opportunity Massive Scale high-performance computing that requires extremely low latency 8

9 Introducing The Sun Constellation System An open systems super computer designed for petascale packaged as an integrated product Massive Scalability: Optimized compute, storage, networking and software technologies and services Dramatically Reduced Complexity: Integrated connectivity and management to reduce start-up, development and operational complexity Breakthrough Economics: Technical innovation resulting in fewer components and high efficiency systems in a tightly integrated solution 9

10 Sun Constellation System Open Petascale Architecture Delivering the Most Scalable Super Computer The Most Scalable Computing Cluster > 700ns latency (DDR); Up to 1.7 PetaFLOPs; Up to 10 PB > 20% Smaller Footprint than Competition Open Industry Standards > Solaris, Linux, OpenMPI, Open InfiniBand interfaces and management > X64 Computing Architecture > InfiniBand DDR interconnect The Highest Density Compute Cluster > Core switch supports 3456 nodes > Custom rack supports 48 server modules > Sun Fire X4500 storage cluster with 480TB per rack The Easiest to Deploy and Manage > Provides a 6:1 reduction in physical ports and cables > Eliminates 100s of discrete switching elements 10

11 Flexible Configurations Scale to Meet Computing Needs 1 Core Switch Servers: 3,456 PFLOPS: Core Switches Servers: 10,368 PFLOPS: Core Switches Servers: 6,912 PFLOPS: Core Switches Servers: 13,824 PFLOPS: 1.7

12 Sun Constellation System Open Petascale Architecture Radical Simplicity: Building out a 3456 Node HPC Super Computer Sun Constellation ks c Ra System Cluster Competitors Compute cks a R Clusters af Le s he re hes Co itc Sw it c Sw Competitors Cabling Infrastructure Ca Alternative Open Standards Fabric 300 Switching Elements 6912 Cables 92 Racks 12 ng i l b Reduced Cabling g in l b a C Constellation System Open Super Computer 1 Switching Element 300:1 Reduction 1152 Cables 6:1 Reduction 74 Racks 20% Smaller footprint

13 Sun Constellation System Open Petascale Architecture Eco-Efficient Building Blocks Compute Networking Storage Software Developer Tools Grid Engine Provisioning Linux Ultra-dense Blade Ultra-dense Platform Switch Solution Fastest Processors: SPARC, AMD Opteron, Intel Xeon Highest Compute Density Fastest Host Channel Adaptor port InfiniBand Switch Unrivaled cable simplification Most economical InfiniBand cost/port Ultra-dense Storage Solution Comprehensive Software Stack Integrated Developer Tools Integrated Grid Engine Infrastructure Provisioning, Monitoring, Patching Simplified Inventory Management Most economical and scalable parallel file system building block Up to 48 TB in 4RU Direct Cabling to IB Switch

14 Sun Blade 6000 Modular System 10 Server Module Capacity Compute 10 Server Modules I/O 1.42Tb/s I/O per Chassis 20 Ho1t-Plug PCIe ExpressModules(TM) for granular blade I/O configuration 2 PCIe Network Express Modules(TM) for multi blade I/O configuration Availability Hot Swap fans Hot Swap power supplies Redundant power grid connection capability Management SNMP, SSH, CLI Form Factor 10 Rack Units 40 Opteron Cores 80 Intel Cores 80 SPARC cores Page: 14 Sun Internal and Authorized Partners Only

15 Chassis Front View 10 Server Modules per chassis The chassis is 10 RU System power > 1+1 Hot-swap power supplies > 6,000W (provide head room to power future technology) > Two plugs and cords per power supply 15

16 Chassis Rear View 20 x PCI Express ExpressModules > Two per Server Module 2 x PCI Express Network Express Modules (NEM) 1 x Chassis Monitoring Module Cooling Fans > 6 x Rear Fan Modules > Hot-Swap > Redundant (N+1) 4 x power inlets with cable holders > Two inlets per power supply > Cable holders prevent accidental loss of power 16

17 Chassis Air Flow Air flow in the chassis is front to rear Two separate air flows > One is powered by the Front Fan Modules within the Power Supplies > Second is powered by the Rear Fan Modules which cools the Server Modules 17

18 Power Supplies Two hot swap redundant power supplies per chassis > A single power supply can power the entire chassis 18 Each requires two power inlets Each consumes 6000 [W] Power supply output is 12 [V] Each holds a Front Fan Module

19 Front Fan Modules 19 Redundant fan modules 100 [CFM] each Fans fit in the Power Supply Modules Can be replaced by pulling the Power Supply 4-5 Used to cool the power supplies and the PCI-E ExpressModules, Network Express modules and CMM

20 Rear Fan Modules N+1 hot-swap Fans accessible from the rear of the chassis Used to pull air through the Server Modules Redundant in-line fans Easy removal handle Fault Indicator Total of 800 [CFM] 20

21 Power Inlets Two power cords are required per power supply Input power is rated at 6000W per power supply in an 1+1 redundant configurations Each power inlet requires connection to a [V] at 16-20[A] outlet Power inlets have a metal retainer which prevents accidental removal of the power cord 21

22 Power Connections Redundant and hot-swap > Grid Redundant Total PSU rating: 6,000 [W] High-efficiency power supplies: approximately 90% Each power cord is cabled to a power supply unit > Two power cords are needed per power supply > Four power cords are needed for full 1+1 redundancy Power cord types > AMER: L6-20P to IEC 320 C19, 2.5m, Sun p/n > EPAC: IEC 309 to IEC 320 C19, 2.5m, Sun p/n Power input: [A] 22

23 Ordering Configurations Each base chassis includes: > > > > Enclosure 2 x Power Supplies All fan modules Chassis Monitoring Module One to Four chassis per 42 RU Sun Rack Rack sold separately > Requires Power Distribution Units 23

24 Sun Blade 6048 Chassis Compute 4 x Shelves per chassis 48 x Sun Blade 6000 series server modules Sun UltraSPARC Intel Xeon AMD Opteron I/O 96x Hot-Plug PCIe ExpressModules 8x Hot-Plug PCIe Network Express Modules 12 1xGbit Ethernet connections per NEM Availability Hot swap redundant fans Eight Rear Fan modules per shelf Two Front Fan Modules per shelf Hot swap power supply modules Two 9000 W power supplies per shelf Total of 8 power supplies per chassis Management 4 x Chassis Monitoring Modules Solaris, Linux, or Windows OS, VMware Density 48 Servers 192 Sockets / 768 cores Page: 24 Sun Internal and Authorized Partners Only

25 Ultra-Dense Blade Platform Delivering the Most Efficient and Eco-Friendly Node Architecture The first blade platform designed for extreme density and performance > 6 TFLOPs, 768 cores per chassis / 42U 50% more compute power than HP C-Class 71% more compute power than IBM BladeCenterH > 4 InfiniBand Leaf Switch Network Express Modules Lowest cost per port with Ultra-Dense Switch Solution Pay as you grow platform ideal for fast growing businesses > Choose among SPARC, AMD Opteron and Intel Xeon CPU technologies Runs General Purpose Software > Custom compiles and tuning are not required Realize economies of scale savings in power and cooling 25

26 The Chassis is the Rack Up to 48 Server Modules; Up to 6 TFLOPS per Rack Chassis Monitoring Module (CMM) and Power Interface Module Up to 24 PCIe ExpressModules (EM) 4 Shelves: 1 to 12 Server Modules N+N Power Supply Modules Up to 2 PCIe Network Express Modules (NEM) 8 Fan Modules Front 26 Back

27 Sun Blade 6048 shelf detail front Shelf Operator panel > Shelf status > Power and Locator LED's Two hot-swap Power Supply Modules (PSM) > Each PSM includes a Front Fan Module > Each PSM requires three 200 V inlets > 3 x 3000W = 9000W to power a shelf Twelve Sun Blade 6000 series Modular Servers 27

28 Sun Blade 6048 shelf detail rear Six power inlets Twenty four PCIe ExpressModules > Two per server module One Chassis Monitoring Module One or two PCIe Network Express Modules > 12 x 1GbEth pass-through > IB NEM takes up two NEM slots 28 Eight dual in-line Rear Fan Modules

29 Power Supplies Two hot swap redundant power supplies per shelf > A single power supply can power the entire shelf 29 Each requires three power inlets Each consumes 9000 [W] Power supply output is 12 [V] Each holds a Front Fan Module

30 Front Fan Modules 30 Redundant fan modules 135 [CFM] each Fans fit in the Power Supply Modules Can be replaced by pulling the Power Supply 4-5 Used to cool the power supplies and the PCI-E ExpressModules, Network Express modules and CMM

31 Rear Fan Modules N+1 hot-swap Fans accessible from the rear of the chassis Used to pull air through the Server Modules Redundant in-line fans Easy removal handle Fault Indicator Total of 1050 [CFM] 31

32 Power Connections Redundant and hot-swap > Grid Redundant Total PSU rating: 9,000 [W] High-efficiency power supplies Each power cord is cabled to a power supply unit > Three power cords are needed per power supply > Six power cords are needed for full 1+1 redundancy Power cord types > AMER: L6-20P to IEC 320 C19, 2.5m, Sun p/n > EPAC: IEC 309 to IEC 320 C19, 2.5m, Sun p/n Power input: [A] 32

33 Gigabit Ethernet Pass-through 12 port NEM Single width NEM up to two per shelf External Network Ports 33 Blade 0 Blade 1 Blade 2 Blade 3 Blade 4 Blade 5 Blade 6 Blade 7 Blade 8 Blade 9 Blade 10 The Gigabit Ethernet pass-through NEM provides connectivity to external network switches which allow Server Module communications to the outside Blade 11 Midplane connectors

34 Sun Blade 6048 InfiniBand switched NEM HCA HCA HCA HCA HCA HCA 24 port 384Gbps IB switch HCA HCA HCA HCA PCIe x8 PCIe x8 PCIe x8 PCIe x8 PCIe x8 PCIe x8 PCIe x8 PCIe x8 PCIe x8 PCIe x8 PCIe x8 PCIe x8 Double width NEM takes up both slots of a shelf Twelve dual port Host Channel Adapters (HCA) HCA HCA 24 port 384Gbps IB switch > Two 4x InfiniBand uplinks per server module Two 24 port InfiniBand switches > 12 x4 ports used for Twelve 1GbEthernet uplinks passthrough 34 Eight 12x InfiniBand uplinks through switches the HCA connection > 4 x12 ports used for the uplink

35 Sun Blade 6000 Family Modules Passive Midplane Server Modules > Sun Blade T6320 and T6300 Server Module > UltraSPARC T2(R) UltraSPARC T1(R) respectively > Sun Blade X6220 Server Module > AMD Next Generation Opteron 2000 series > Sun Blade X6250 Server Module > Intel Xeon 5100 and 5300 series PCI Express Network Express Module (NEM) PCI Express ExpressModule (EM) Chassis Monitoring Module (CMM) 35

36 Passive Midplane Network Express Module connectors Each NEM provides: To every Server Module Server Module I/O connectors Network Express Modules Two PCI Express x8 interfaces or Two XAUI interfaces (GbE, FC or IB) Serial Attached SCSI links (4 total) Gigabit Ethernet links (2 total) PCI ExpressModules Two PCI Express x8 interfaces Service Processor Ethernet link I2C Network PCI Express x8 interface or XAUI interface (GbE, FC or IB) Serial Attached SCSI links (2 total) Gigabit Ethernet link (1 total) CMM Ethernet link I2C Network Unidentified connectors are Fan Connectors 36 PCI-E ExpressModule Connectors to Server Modules Rear NEM, EM and Rear Fan Module Connectors CMM connector Server Module power connectors Front Panel LED control board Front Server Module and Power Supply Connectors

37 Passive Midplane Data Interfaces x8 E I PC E x8 I C P Service P roc AUI o r X et E x8 rn PCI- it Ethe ab Gi g SAS AUI or X et E x8 rn PCI- it Ethe ab Gig SAS 37 essor Eth ernet

38 Passive Midplane Sun Blade T6300 PCI Express Links to ExpressModules PCI Express Links to Network Express Modules Gigabit Ethernet Links SAS Links Total Server Module Bandwidth Service Processor Links 38 Sun Blade X6220 Interface No. of No. of Bandwidth interfaces interfaces [Gbps] (8 lanes) (8 lanes) Sun Blade X6250 with REM module With PCI Expre ss FEM With other fabric FEM Interface Interface No. of Bandwidth Bandwidth interfaces [Gbps] [Gbps] (8 lanes) (8 lanes) (8 lanes) (4 lanes) Interface Bandwidth [Gbps] 32 (8 lanes) XAUI = variable

39 UltraSPARC Server Modules 39

40 Sun Blade T6320 Server Module Single Socket Enterprise-Class Data Center Compute Engine Page: 40 Compute 1 UltraSPARC T2 Processor with 4, 6 or or 1.4 GHz and 64 threads. 16x FB-DIMM slots - 64 GB memory using 4GB DIMM's I/O 142 Gbps of throughput using I/O modules 2x Hot-Plug PCIe ExpressModules 2x Hot-Plug PCIe or 10GbEthernet Network Express Modules 1xGbit Ethernet connection per NEM 2xSAS storage links per NEM 4x SAS or SATA 2.5 disk drives Availability Hot-swap disks; RAID 0 or 1 basic REM Optional BBWC w/raid 0, 1, 5, 6, 10, 50, 60 No Fans (on blade) No PSU (on blade) Management ILOM 2.0 Remote Management Solaris(TM) operating system Density 1 Socket/8 cores/64 threads per RU Sun Internal and Authorized Partners Only

41 Quick Specs Single socket UltraSPARC T2 based Server Module 16 FB-DIMMs (up to 64 GB RAM max with 4GB DIMM's) > 128 GB at RR+1Q (with 8GB DIMM's) 4 PCI-Express slots > Two PCIe ExpressModule x8 slots and > Two x4 PCIe or 10GbEthernet Network Express Modules 2 Intel GigE ports onboard available through the Network Express Modules Storage > Four SAS links to the midplane for external storage expansion > Four internal SAS or SATA links for 2.5 Small Form Factor hard drives 2 Disk Controller options > Basic RAID 0, 1 RAID Expansion Module based on the LSI1068e controller (Jackal) > Advanced BBWC RAID 0, 1, 5, 10, 50, 60 using StorageTek storage controller (Coyote) Hot swappable and redundant fans and PSUs 41 ILOM 2.0 Service Processor with legacy ALOM command line capability

42 Sun Blade T6320 Server Module Memory Fabric Expansion Module (FEM) PCIe x4 or 10GbE UltraSPARC Niagara 2 Processor 10 GbEthernet PCIe x4 or 10GbE 10 Gb Ethernet T2 PCIe x4 PCIe x4 PCIe x4 PCIe to PCI Bridge PCIe x8 32Gbps Intel Ophir 2x Gbit Ethernet PCIe x8 32Gbps EM #1 RAID Expansion Module SAS HDDs SAS links USB Blade Module Front Panel and adapter VGA Output ILOM 2 SERIAL NEM #0 NEM #1 PCIe x4 PCI to USB USB 2.0 NEM #1 NEM #0 EM #0 PCIe x4 16Gbps PCIe Switch PEX8548 PCIe x8 42 Passive Midplane NEM #0 NEM #1 ATI Graphics Motorola MPC885 based ILOM 2 SP 10/100Mbps Mgmt Ethernet CMM

43 Sun Blade T6320 ILOM 2.0 Service Processor Connctor UltraSPARC T2 processor PCIe FEM connector XAUI FEM connector PCIe or XAUI interfaces, Four SAS links and two 1GbEth ports Four SAS/SATA Hard Drives PCIe bridge ATI VGA Controller 43 Fault 16 x FB-DIMM slots Remind button REM connector

44 Sun Blade T6320 ILOM 2.0 Service Processor Card 44 Fabric Expansion Module Card RAID Expansion Module Card

45 RAID Expansion Module (REM) All standard configurations will ship with the Jackal REM Based on the LSI SAS1068E storage controller Hardware RAID capabilities > RAID 0, 1 or 10 raidctl, Linux, Windows and BIOS management capabilities 45

46 Sun Blade T6300 Server Module Single Socket Enterprise-Class Data Center Compute Engine Page: 46 Compute 1 UltraSPARC T1 Processor with 6 or 8 1.0, 1.2 or 1.4 GHz and up to 32 threads. 32 GB memory, 8x DIMM slots I/O 142 Gbps of throughput using I/O modules 2x Hot-Plug PCIe ExpressModules 2x Hot-Plug PCIe Network Express Modules 1xGbit Ethernet connection per NEM 2xSAS storage links per NEM 4x SAS or SATA 2.5 disk drives Availability Hot-swap disks; RAID 0 or 1 built-in No Fans (on blade) No PSU (on blade) Management ALOM Remote Management Solaris(TM) operating system Density 1 Socket/8 cores/32 threads per RU Sun Internal and Authorized Partners Only

47 Sun Blade T6300 Server Module Features Single UltraSPARC T1 processor with 6 or 8 cores > 1.0 GHz, 1.2 GHz or 1.4 GHz speed bins High memory density > 8 DIMM slots for a total of 32 GB of RAM per blade > 1GB, 2GB and 4GB DDR2 DIMMs > All four memory controllers in the processor are used Large I/O capacity > Four PCI Express interfaces > 2 x PCI Express ExpressModules (x8) > 2 x PCI Express Network Express Module (NEM) interfaces (x8) > Dual on-board Gigabit Ethernet interfaces available via NEM > Four on-board SAS links for external expansion via NEM 47

48 Sun Blade T6300 Server Module Features Versatile storage > 4 hot-swap small form factor (2.5 ) SAS or SATA hard drives > RAID 0 or 1 support (LSI SAS1068E) Solaris 10 Update 3 Advanced Lights Out Management (ALOM) Service Processor is a standard feature > CLI management (telnet, ssh) > Sun N1(TM) System Manager support USB 2.0 and serial ports are available through front panel connector 48

49 Sun Blade T6300 Block Diagram DDR2 Memory 10.7 GB/sec UltraSPARC T1 Processor PCIe x8 32Gbps PCIe x8 PCIe Bridge JBUS EM #0 PCIe x8 32Gbps NEM #0 PCIe x4 16Gbps Fire Chip Intel Ophir 2x Gbit Ethernet 10.7 GB/sec PCIe x8 32Gbps PCIe x8 Fire EBus PCIe Bridge Passive Midplane NEM #0 NEM #1 EM #1 PCIe x8 32Gbps NEM #1 UART PCIe x4 HDDs SAS links PCIe RJ-45 Serial ALOM Posix serial USB 2.0 DB-9 Serial Posix LSI SAS SAS1068E NEM #1 PCI to USB Blade Module Front Panel and adapter USB PCIe to PCI Bridge Motorola MPC885 based ALOM SP ALOM SERIAL JUNTA FPGA 49 NEM #0 10/100Mbps Mgmt Ethernet CMM

50 Sun Blade T6300 Server Module Device Map Integrated hardware RAID controller for internal and external storage capabilities PCI-Express Bridges 4 DIMM sockets DDR2 Four internal SAS or SATA hard drives CPU Four PCIe x8 lanes Four SAS interfaces Two Gigabit Ethernet ports 4 DIMM sockets DDR2 Fire Chip JBUS to PCI-Express bridge 50 Per-blade ALOM management capabilities

51 x64 Server Modules 51

52 Sun Blade X6250 Server Module Dual Socket Enterprise-Class Data Center Compute Engine Page: 52 Compute Intel Xeon(TM) 5100 or 5300 series processor 64 GB memory, 16x DIMM slots I/O 110 Gbps of throughput 2x Hot-Plug PCIe ExpressModules 2x Hot-Plug PCIe Network Express Modules 1xGbit Ethernet connection per NEM 2xSAS storage links per NEM (with REM) 4x SAS (with REM) or SATA 2.5 disk drives Optional Fabric Expansion Module (FEM) RAID Expansion Module (REM) Availability Hot-swap disks; REM provides RAID 0, 1, 5 and 10 with built-in with write cache and battery backup No Fans or PSU's (on blade) Management Embedded LOM Service Processor; IPMI 2.0; remote KVM, Floppy/CDROM Solaris, Linux, or Windows OS, VMware Density 2 Sockets/8 cores/8 threads per RU Sun Internal and Authorized Partners Only

53 Sun Blade X6250 Server Module Features 64-bit Processor Technology > 2 Intel Xeon 5300 series processors (L5310, E5320, E5345, X5355) > 2 Intel Xeon 5100 series dual-core processors (E5160 ATO only) > L series = 50 W, E series = 80W, X series = 120W High memory density > 16 memory slots for a total of 64 GB of RAM per blade > 1GB, 2GB and 4GB FBDIMMs Large I/O capacity > Four PCI Express interfaces > 2 x PCI Express ExpressModules (x8) > 2 x PCI Express Network Express Module (NEM) interfaces 53 Available using the Fabric Expansion Module (FEM) which splits the x8 interface into two x4 interfaces FEM will become available when PCI-Express NEM's become available > Dual on-board Gigabit Ethernet interfaces available via NEM

54 Sun Blade X6250 Server Module Features Versatile storage > 4 internal hot-swap small form factor (2.5 ) SAS or SATA hard drives > SAS requires the RAID Expansion Module (REM) which is included in default configurations but is an option on XATO orders > REM includes RAID 0,1, 5 and 10 with write cache and battery backup Operating System flexibility > Solaris, Linux, Windows, VMware Embedded LOM Service Processor is a standard feature > IPMI 2.0, HTTP(S) interface, CLI management, remote KVMS over Ethernet, SNMP USB 2.0, Video and serial (Service Processor) ports are available through front panel connector 54

55 Sun Blade X6250 Block Diagram PCIe x8 32Gbps PCIe x8 32Gbps Intel 5000 MCH PCIe x4 or XAUI Fabric Expansion Module (FEM) ESI PCIe x8 10.5GB/s 5.3 GB/sec 10.5GB/s 5.3 GB/sec Intel 5100 or 5300 EMT64 processors PCIe x4 or XAUI Gbit Ethernet Gbit Ethernet Gigal ESB2 IO PCI Bridge PCIe x8 32Gbps IDE SERIAL VGA HD-15 DB-9 Serial 55 PCI USB 2.0 Blade Module Front Panel and adapter VGA Video Output RAID Expansion Module (REM) EM #1 NEM #0 NEM #1 NEM #0 NEM #1 EM #0 Compact Flash SATA x4 PCIe x4 LPC Super I/O USB 2.0 Passive Midplane 5.3 GB/sec 5.3 GB/sec FBDIMM 667 Memory SAS/SATA HDDs SAS HW RAID Controller SAS links MUX NEM #0 NEM #1 AST2000 Service Processor 10/100 PHY 10/100Mbps Mgmt Ethernet CMM

56 Sun Blade X6250 Server Module Device Fabric Expansion Northbridge and PCI-E Map Module (FEM) connector expansion HUB 8 DIMM sockets FB-DIMM 667 Four internal SAS or SATA hard drives CPU1 CPU0 8 DIMM sockets FB-DIMM Four PCIe x8 lanes Four SAS interfaces Two Gigabit Ethernet ports Per-blade Embedded LOM service processor capabilities CompactFlash card reader boot device Integrated hardware RAID controller for internal and external (future - through NEM) storage capabilities

57 Sun Blade X6450 Server Module Quad Socket Enterprise-Class Data Center Compute Engine Compute 2 or 4 Intel Xeon(TM) 7000 sequence processor 24x FB-DIMM slots - 96 GB using 4GB DIMMs I/O 110 Gbps of throughput 2x Hot-Plug PCIe ExpressModules 2x Hot-Plug PCIe Network Express Modules 1xGbit Ethernet connection per NEM 2xSAS storage links per NEM (with REM) Optional Fabric Expansion Module (FEM) RAID Expansion Module for external storage (REM) CompactFlash card for boot or storage Availability No disks No Fans (on blade) No PSU (on blade) Management Embedded LOM Service Processor; IPMI 2.0; remote KVM, Floppy/CDROM ILOM 1Q after RR Solaris, Linux, or Windows OS, VMware Density 4 Sockets/16 cores/16 threads per RU Page: 57 Sun Internal and Authorized Partners Only

58 Sun Blade X6450 Quick Specs 4-socket Intel Xeon 7000 Sequence based Server Module > 4 Intel Xeon 7200/7300 Series (Dual- or Quad-Core) Processors > 50W or 80W only > Intel chipset (Clarksboro MCH Northbridge + ESB-2 Southbridge) > 24 FB-DIMMs (up to 96 GB RAM max using 4GB DIMMs) 4 PCI-Express slots (Two PCIe ExpressModule x8 slots and Two PCIe Network Express Module x4 interfaces via a FEM) 2 Intel GigE ports onboard available through the Network Express Modules CompactFlash slot as an optional internal storage or boot device Optional RAID Expansion Module (REM) for external storage connectivity > Provides four SAS links to the midplane for external storage expansion Hot swappable and redundant fans and PSUs Embedded LOM Service Processor [ILOM available 1Q after RR] 58

59 Sun Blade X6450 Block Diagram FBDIMM 667 Memory Fabric Expansion Module (FEM) PCIe x8 32Gbps Clarksboro North Bridge ESI RAID Expansion Module (REM) SAS HW RAID Controller PCIe x8 5.3 GB/sec PCIe x4 8.5GB/s PCIe x4 or XAUI PCIe x4 or XAUI 5.3 GB/sec Intel EMT64 processors 8.5GB/s 5.3 GB/sec 5.3 GB/sec 8.5GB/s Passive Midplane 8.5GB/s PCIe x8 32Gbps SAS links NEM #0 NEM #1 EM #0 NEM #0 NEM #1 ESB2 IO PCI Bridge PCIe x8 32Gbps EM #1 LPC IDE Compact Flash Super I/O 59 Blade Module Front Panel and adapter VGA Video Output MUX PCI SERIAL VGA HD-15 DB-9 Serial or RJ45 PCIe x8 32Gbps USB 2.0 USB 2.0 ILOM 2.0 Service Processor 10/100 PHY Gigal Gbit Ethernet Gbit Ethernet 10/100Mbps Mgmt Ethernet NEM #1 NEM #0 CMM

60 Sun Blade X6450 Server Module 24 FB-DIMM slots. Up to 96 GB of RAM FEM connector Four Intel 7000 processors. Dual or quad-core. Four PCIe interfaces, four SAS links and two 1GbEth ports Intel 7000 MCH (Clarksboro) Northbridge Compact Flash Storage REM connector Fault remind button ESB2 I/O bridge 60 Battery location for the REM

61 FB-DIMM memory population rules The Memory Controller Hub (MCH) provides four FBDIMM memory channels The first DIMM slot of each channel is identified by the white ejector handles Populate DIMMs using all channels > Follow ABCD then 0123 > A0, B0, C0, D0 then A1, B1, C1, D1, etc.. Populate larger DIMM sizes closer to the MCH > 4GB first, 2GB second and 1GB third > 4GB in A0, B0, C0, D0 then 2GB in A1, B1, C1, D1, etc.. 61

62 RAID Expansion Module (REM) All standard configurations will ship with the REM Optional add-on card for XATO orders only > If not used, the server may boot from CompactFlash slot or SATA interfaces derived from the Enterprise South Bridge 2 Hardware RAID capabilities > 128 MB of cache > Battery Backed - LiIon (72 hours when fully charged) > RAID 0, 1, 5 or 10 Adaptec Storage Manager software is used to monitor the storage solution 62

63 Embedded LOM service processor Remote management of server module Accessible over a serial line through the front panel dongle Network access is available through the CMM network interface and it provides: Sun Microsystems Embedded Lights Out Manager Copyright 2006 Sun Microsystems, Inc. All rights reserved. Hostname: SUNSP001636F16730 IP address: MAC address: 00:16:36:F1:67:30 -> version SM CLP Version v1.0.0 SM ME Addressing Version v > show / Targets: SP SYS CH > On-board CLI management over 63 SSH > IPMI and SNMP management from a management console > Full featured web GUI management Properties: Target Commands: show cd ->

64 Embedded LOM service processor ipmitool management Web GUI management bash-3.00$ ipmitool -H U root sdr Password: CPU 0 Temp 92 degrees C ok CPU 1 Temp 92 degrees C ok VRD 0 Temp 23 degrees C ok VRD 1 Temp 22 degrees C ok DIMM 0 Temp disabled ns DIMM 1 Temp disabled ns P_VCCP Volts ok P_VCCP Volts ok P1V2_VTT 1.20 Volts ok P1V5_MCH 1.49 Volts ok P2V Volts ok P1V8_B Volts ok P1V2_NIC 1.22 Volts ok... System Event Critical INT Button Boot Error Watchdog bash-3.00$ 64 Not Not Not Not Not Readable Readable Readable Readable Readable ns ns ns ns ns

65 Embedded LOM service processor Menus provide quick access to storage setup and I/O functions as well as configuration of ALT, function or CTRL based hot-keys Viewing window presents all POST and BIOS messages and shows interaction with the server platform Network link and storage icons indicate if any of these functions are active for the Java Remote Console tab. 65

66 Sun Blade X6220 Server Module 2-Socket Enterprise-Class Data Center Compute Engine Page: 66 Compute 2 AMD Next Generation Opteron Sockets Dual-core only 64 GB memory, 16x DIMM slots I/O 142 Gbps of throughput using I/O modules 2x Hot-Plug PCIe ExpressModules 2x Hot-Plug PCIe Network Express Modules 1xGbit Ethernet connection per NEM 2xSAS storage links per NEM 4x SAS or SATA 2.5 disk drives Availability Hot-swap disks; RAID 0 or 1 built-in No Fans or PSU's (on blade) Management ILOM Service Processor featuring IPMI 2.0; remote KVM, Floppy/CDROM Solaris, Linux, or Windows Density 2 Sockets/4 cores/4 threads per RU Sun Internal and Authorized Partners Only

67 Sun Blade X6220 Server Module Features 64-bit Processor Technology > 2 AMD Next Generation Opteron 2000 series processors > 2212, 2218, ATO: {2212, 2218, 2220} (95W), {2222} (120W) High memory density > 16 memory slots for a total of 64 GB of RAM per blade > 1GB, 2GB and 4GB DDR2 DIMMs at 667 MHz > When all DIMMs are populated, the memory speed is reduced to 533MHz Large I/O capacity > Four PCI Express interfaces > 2 x PCI Express ExpressModules > 2 x PCI Express Network Express Module (NEM) interfaces > Dual on-board Gigabit Ethernet interfaces derived from the 67 nvidia(tm) chipset are available via NEM > Four on-board SAS links for external expansion via NEM

68 Sun Blade X6220 Server Module Features Versatile storage > 4 internal hot-swap small form factor (2.5 ) SAS or SATA hard drives > 4 SAS links available through NEM for future expansion capabilities > On-board RAID 0 or 1 support via LSI SAS1068e Operating System flexibility > Solaris, Linux, Windows, VMware ILOM Service Processor is a standard feature > IPMI 2.0, HTTP(S) interface, CLI management, remote KVMS over Ethernet, SNMP USB 2.0, Video and Service Processor serial ports are available through front panel connector 68

69 Sun Blade X6220 Block Diagram Passive Midplane 10.7 GB/sec DDR2 667 Memory PCIe x8 32Gbps Next Generation AMD Opteron 2000 series processors 8 GB/s EM #1 PCIe x8 32Gbps IO-04 PCIe bridge NEM #1 Gbit Ethernet Gbit Ethernet NEM #1 NEM #0 PCIe x8 32Gbps 8 GB/s 10.7 GB/sec 3 USB 2.0 ports Remote KMS LSI SAS SAS1068e Compact Flash LPC 33MHz PCIe x4 HDDs PCI VGA HD-15 Blade Module Front Panel and adapter VGA Video Output SERIAL 69 NEM #0 IDE SAS links USB 2.0 USB 2.0 DB-9 Serial EM #0 PCIe x8 32Gbps nforce4 CK8-04 NEM #0 NEM #1 Super I/O Controller ATI RageXL DVI Video Output Video over LAN Redirect Motorola MPC8275 SP CMM BCM 10/100Mbps Mgmt Ethernet

70 Sun Blade X6220 Server Module Device Map Integrated hardware RAID controller for internal and external (future - through NEM) storage capabilities 8 DIMM sockets DDR2 667 CPU1 Four internal SAS or SATA hard drives CPU0 8 DIMM sockets DDR Nvidia nforce CK8-04 and IO-04 PCI Express I/O Bridge Four PCIe x8 lanes Four SAS interfaces Two Gigabit Ethernet ports CompactFlash card reader boot device Per-blade ILOM management capabilities

71 Sun Blade X6220 ILOM service processor Remote management of server module Accessible over a serial line through the front panel dongle Network access is available through the CMM network interface and it provides: > On-board CLI management over 71 Sun(TM) Integrated Lights Out Manager Version 1.0 Copyright 2005 Sun Microsystems, Inc. All rights reserved. Warning: password is set to factory default. -> SP SP SP SP version firmware version: 1.0 firmware build number: 9306 firmware date: Tue Feb 28 16:01:24 PST 2006 filesystem version: > show SSH > IPMI and SNMP management from a management console > Full featured web GUI -> management / Targets: SP SYS Properties: Commands: cd show

72 Sun Blade X6220 ILOM service processor ipmitool management Web GUI management bash-3.00$ /opt/ipmitool/bin//ipmitool U root -P changeme sdr sys.id 0x02 sys.intsw 0x00 sys.psfail 0x01 sys.tempfail 0x01 sys.fanfail 0x01 mb.t_amb 27 degrees C mb.v_bat 3.12 Volts mb.v_+3v3stby 3.27 Volts mb.v_+3v Volts mb.v_+5v 4.99 Volts -H ok ok ok ok ok ok ok ok ok ok.... ft1.fm2.f0.speed ft0.fm0.f1.speed ft0.fm1.f1.speed ft0.fm2.f1.speed ft1.fm0.f1.speed ft1.fm1.f1.speed ft1.fm2.f1.speed bash-3.00$ RPM RPM RPM RPM RPM RPM RPM ok ok ok ok ok ok ok

73 Sun Blade X6220 ILOM service processor Tabs provide multiple ILOM sessions through one Java Remote Console instance Menus provide quick access to storage setup and I/O functions as well as creation of new ILOM sessions Viewing window presents all POST and BIOS messages and shows interaction with the server platform Keyboard, Mouse, CDROM and Floppy icons indicate if any of these functions are active for the current active Java Remote Console tab. 73

74 Components common to Server Modules 74

75 Fault Remind Button To diagnose a Blade Server Module, it must be removed from the chassis > This means power is no longer available to the Server Module Push-button system holds a charge to identify failed components within the Module > CPUs > DIMMs 75

76 Server Module Hard Drives - SAS Serial Attached SCSI (SAS) 2.5 compact form factor Server grade > Hot swappable > High performance 10,000 RPM > Faster than 10k RPM SCSI drives > High density 73 or 146 GB > Higher densities offered when available > Enterprise-class reliability > 1.6M hours MTBF 76

77 Server Module Hard Drives - SATA Serial ATA (SATA) 2.5 compact form factor Server grade > Hot swappable > 5400 RPM > High density 80 GB > Higher densities offered when available > More than 500k hours MTBF 77

78 Server Module Hard Drive Controller (TM) LSI SAS1068e X6220 and T6300/T6320 ONLY 8 SAS ports Each port capable of 3.0 Gbit/s SAS link rates Total available SAS bandwidth: 24 Gbit/s Available through PCIe: 16Gbit/s LSI Integrated Hardware RAID (Low cost RAID solution that offloads CPU) Based on Fusion-MPT architecture Internal Storage Tx, Rx Tx, Rx Tx, Rx Tx, Rx SAS Device SAS Device SAS Device Tx, Rx SAS Device SAS Device 78 LSI SAS1068e SAS Device Tx, Rx SAS Device Tx, Rx Four ports are used for the internal hard drives Tx, Rx SAS Device NEM 0 NEM 1 Four ports are used for the external storage connections through NEM

79 Server Module Adapter (Octopus cable) x64 Servers St. Paul 79 DB-9 Service Processor Serial POSIX Serial HD-DB15 RJ-45 USB VGA output N/A USB 2.0 N/A Serial Processor (ALOM) serial USB 2.0

80 Network Express Module Constellation Modular System unique form factor Connects via midplane to all 10 blades in chassis Provides bulk or aggregated I/O options Appears to blades as standard PCI-Express adapter May implement an exposed or hidden management model, depending on function Provides termination for Server Module storage and network interfaces 80

81 Gigabit Ethernet Pass-through NEM External Network Ports 81 Blade 0 Blade 1 Blade 2 Blade 3 Blade 4 Blade 5 Blade 6 Blade 7 Blade 8 The Gigabit Ethernet pass-through NEM provides connectivity to external network switches which allow Server Module communications to the outside Blade 9 Midplane connectors

82 PCI Express ExpressModule (EM) New PCI-SIG standard form factor > 32Gb/s I/O per module (x8 PCI/E lanes) 2 EMs for each Server Module > 20 EMs per chassis 82 Highly Serviceable > Hot-Pluggable > Fully customer replaceable unit (CRU) without opening chassis or blade Industry-standard I/O > More I/O options, no vendor lock-in

83 PCI Express ExpressModule Industry standard hot-plug enclosure for safe/reliable replacement and handling Rear connectors for easy connectivity to external I/O 83 Standard PCIe silicon ExpressModule shown with the protective cover removed

84 PCI Express ExpressModules EMs available from Sun: > Dual-port GbE EM > Intel NICs > Dual-port 4Gbps FiberChannel EM > Qlogic(TM) > Dual-port 4X InfiniBand EM 84 > Mellanox(TM) Other available EMs: > Quad-port GbE EM > 10GbE EM > Combo card 2 x 1GbE + 2 x 4Gb FC

85 InfiniBand ExpressModule Dual port 4x InfiniBand EM Produced by Mellanox, productized by NSN Based on MT25208 InfiniHost III Ex PCI Express x8 lane width 256MB of onboard memory Drivers will be available for Solaris, Win2k3 and Linux 85

86 FibreChannel ExpressModule Dual port 4Gbps FiberChannel EM Produced by Qlogic, productized by DMG Based on the Qlogic ISP2432 FC-to-PCIe controller PCI Express x4 lane width Drivers available for Solaris, Win2k3 and Linux 86

87 GigabitEthernet ExpressModule Dual port 1GbEthernet (Cu) EM Produced by NSN Based on the Intel 82571EB Gigabit Ethernet controller (ophir) Same device available on the NEM PCI Express x4 lane width Drivers available for Solaris, Win2k3 and Linux 87

88 List of available PCIe ExpressModules 4Gb FC Dual Port ExpressModule Qlogic SG-XPCIE2FC-QB4-Z 1GbE Dual Port ExpressModule Copper X7282A-Z 1GbE Dual Port ExpressModule Fiber X7283A-Z 4X IB SDR 256MB Dual Port ExpressModule Mellanox X1288A-Z 4Gb FC Dual Port ExpressModule Emulex SG-XPCIE2FC-EB4-Z 12Gb SAS Dual Port ExpressModule -LSI Logic SG-XPCIE8SAS-EB-Z 12Gb SAS Single Port RAID ExpressModule Intel SRL SGXPCIESAS-R-BLD-Z 1GbE Quad Port ExpressModule Copper (Intel) X7284A-Z 1GbE Quad Port ExpressModule Copper (Neptune) X7287A-Z 10GbE Dual Port ExpressModule Fiber (Neptune) X1028A-Z 4X IB DDR Nomem Single Port EM Mellanox (Hermon) X1290A 88

89 Constellation Modular System Chassis Monitoring Module (CMM) Chassis/Enclosure Monitoring and Management Comprehensive management features: > LDAP Authentication > Network access > Secure protocols (SSH2) > Serial access All functions available via through SSH, CLI Easy integration into Sun and 3rd-party management infrastructure Consistent management with rack-mount servers 89

90 Chassis Monitoring Module Serial Interface Network Management Status LEDs 90 Service Processor Module CMM Switch Module

91 Chassis Monitoring Module LED Control Passive Midplane Blade 0 Blade1 Blade 2 Blade 3 Blade 4 Blade 5 Blade 6 Blade 7 Blade 8 Blade 9 Blade 10 NEM 0 NEM 1 91 To CMM Service Processor Unmanaged Switch BCM5321 Gigabit Ethernet Uplink 1 Gigabit Ethernet Uplink 0

92 Management overview CMM provides an SSH/CLI interface for management Shows > Presence of server modules and DMTF's SMASH example -> show / Targets: CH CMM Network Express Modules > Overall status of the chassis components (fans, LED's, PSU) Enables initial configuration of the server modules' service processor network information 92 Properties: Commands: cd show ->

93 Initial setup example through CMM BL0 service processor network setup using CLI Verify settings -> show /CH/BL0/SP/network /CH/BL0/SP/network Targets: -> cd /CH/BL0/SP/network /CH/BL0/SP/network Properties: type = Network Configuration commitpending = (Cannot show property) ipaddress = ipdiscovery = unknown ipgateway = ipnetmask = macaddress = 00:00:00:00:00:00 pendingipaddress = pendingipdiscovery = unknown pendingipgateway = pendingipnetmask = > set pendingipdiscovery=static Set 'pendingipdiscovery' to 'static' -> set pendingipaddress= Set 'pendingipaddress' to ' ' -> set pendingipgateway= Set 'pendingipgateway' to ' ' -> set pendingipnetmask= Set 'pendingipnetmask' to ' ' Commands: cd set show -> set commitpending=true Set 'commitpending' to 'true' -> 93 ->

94 Backup slides follow 94

95 Chassis Summary Server Module Slots PCI-E ExpressModule Slots PCI-E Network Express Module Slots Power Rating Power Supplies Power Inlets Power Redundancy Fans Front Back Remote Management CMM ILOM Redundancy CMM network Redundancy CMM Network Ports CMM Serial Ports Density Rack units Chassis per 42 RU rack Maximum power consumption per rack Cores per rack 95 SB6000 Chassis [W] 2 4 N+N (1+1) SB8000 Chassis [W] 6 6 N + N (3 + 3) SB8000P Chassis [W] 4 4 N + 1 (3 +1) No No 2 1 Yes Yes 2 Standard, 4 Optional 1 Standard, 2 Optional Yes Yes 2 Standard, 4 Optional 1 Standard, 2 Optional [W] [W] [W] 240

96 Blade Summary Server Module CPU Sockets CPU Type X AMD Opteron 2000 Series Maximum Cores Maximum Threads Memory type DIMM sockets I/O interfaces 2 PCI-E ExpressModules NEM PCI-E 2 (x8) Gigabit Ethernet 2 SAS 4 Storage controller LSI SAS1068 Battery backed cache No Hardware RAID 0, 1 On-board HDD 4 x SAS or SATA Service Processor Type ILOM On-board or Mezzanine Mezzanine Front panel connectors (needs dongle) RJ-45 N/A DB-9 ILOM Serial VGA Platform VGA USB USB SB6000 Chassis T X UltraSPARC T1 Intel 5300 Series SB8000/SB8000P Chassis X8400 X AMD Opteron 800 AMD Opteron 8000 Series Series (x8) 2 (x4 if FEM present) 2 (x8) + 2 (x4) (if REM present) 0 Intel/Adaptec LSI SAS1068 LSI SAS1064 No Yes, 128MB No 0, 1 0, 1, 5, 10 0, 1 4 x SAS or SATA 4 x SAS or SATA 2 x SAS or SATA ALOM Mezzanine (needs dongle) ALOM Serial POSIX Serial N/A USB 2.0 Embedded LOM On-board (needs dongle) N/A Emb. LOM Serial Platform VGA USB (x8) + 2 (x4) 0 0 LSI SAS1064 No 0, 1 2 x SAS or SATA ILOM On-board ILOM On-board N/A ILOM Serial Platform VGA USB 2.0 N/A ILOM Serial Platform VGA USB 2.0

Sun Constellation System: The Open Petascale Computing Architecture

Sun Constellation System: The Open Petascale Computing Architecture CAS2K7 13 September, 2007 Sun Constellation System: The Open Petascale Computing Architecture John Fragalla Senior HPC Technical Specialist Global Systems Practice Sun Microsystems, Inc. 25 Years of Technical

More information

HPC Update: Engagement Model

HPC Update: Engagement Model HPC Update: Engagement Model MIKE VILDIBILL Director, Strategic Engagements Sun Microsystems mikev@sun.com Our Strategy Building a Comprehensive HPC Portfolio that Delivers Differentiated Customer Value

More information

Cisco Unified Computing System Hardware

Cisco Unified Computing System Hardware Cisco Unified Computing System Hardware C22 M3 C24 M3 C220 M3 C220 M4 Form Factor 1RU 2RU 1RU 1RU Number of Sockets 2 2 2 2 Intel Xeon Processor Family E5-2400 and E5-2400 v2 E5-2600 E5-2600 v3 Processor

More information

Sun Microsystems Special Promotions for Education and Research January 9, 2007

Sun Microsystems Special Promotions for Education and Research January 9, 2007 Sun Microsystems Special Promotions for Education and Research Solve big problems on a small budget with Sun-Education s trusted partner for cutting-edge technology solutions. Sun solutions help your campus

More information

Chapter 5 Cubix XP4 Blade Server

Chapter 5 Cubix XP4 Blade Server Chapter 5 Cubix XP4 Blade Server Introduction Cubix designed the XP4 Blade Server to fit inside a BladeStation enclosure. The Blade Server features one or two Intel Pentium 4 Xeon processors, the Intel

More information

Pioneer DreamMicro. Blade Server S75 Series

Pioneer DreamMicro. Blade Server S75 Series Pioneer DreamMicro Blade Server S75 Series Advantage of Blade Server? Easy Maintenance Hot Swappable High Availability Redundant Architecture Space Saving Cableless Rack Mount Server Blade Server Pioneer

More information

Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server

Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket node for PRIMERGY CX420 cluster Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket node for PRIMERGY CX420 cluster Strong Performance and Cluster

More information

Power Redundancy. I/O Connectivity Blade Compatibility KVM Support

Power Redundancy. I/O Connectivity Blade Compatibility KVM Support 1.Blade server Blade Chasis Specification Blade Chassis Form Factor 6U-10U rack mountable Chasis to House at least 6 or more Blade Servers Chasis Should be configured with 6 blades Network Redundancy I/O

More information

SUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION

SUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION SUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION AFFORDABLE, RELIABLE, AND GREAT PRICES FOR EDUCATION Optimized Sun systems run Oracle and other leading operating and virtualization platforms with greater

More information

Copyright 2013, Oracle and/or its affiliates. All rights reserved.

Copyright 2013, Oracle and/or its affiliates. All rights reserved. 1 Oracle SPARC Server for Enterprise Computing Dr. Heiner Bauch Senior Account Architect 19. April 2013 2 The following is intended to outline our general product direction. It is intended for information

More information

UCS M-Series Modular Servers

UCS M-Series Modular Servers UCS M-Series Modular Servers The Next Wave of UCS Innovation Marian Klas Cisco Systems June 2015 Cisco UCS - Powering Applications at Every Scale Edge-Scale Computing Cloud-Scale Computing Seamlessly Extend

More information

SUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION

SUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION SUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION AFFORDABLE, RELIABLE, AND GREAT PRICES FOR EDUCATION Optimized Sun systems run Oracle and other leading operating and virtualization platforms with greater

More information

PCI Express Impact on Storage Architectures and Future Data Centers. Ron Emerick, Oracle Corporation

PCI Express Impact on Storage Architectures and Future Data Centers. Ron Emerick, Oracle Corporation PCI Express Impact on Storage Architectures and Future Data Centers Ron Emerick, Oracle Corporation SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA. Member companies

More information

SUN FIRE X4150, X4250, AND X4450 SERVER ARCHITECTURE. Breakthrough Density Using Sun and Intel Technology

SUN FIRE X4150, X4250, AND X4450 SERVER ARCHITECTURE. Breakthrough Density Using Sun and Intel Technology SUN FIRE X4150, X4250, AND X4450 SERVER ARCHITECTURE Breakthrough Density Using Sun and Intel Technology White Paper September 2008 Table of Contents Executive Summary................................................

More information

APACHE HADOOP PLATFORM HARDWARE INFRASTRUCTURE SOLUTIONS

APACHE HADOOP PLATFORM HARDWARE INFRASTRUCTURE SOLUTIONS APACHE HADOOP PLATFORM BIG DATA HARDWARE INFRASTRUCTURE SOLUTIONS 1 BIG DATA. BIG CHALLENGES. BIG OPPORTUNITY. How do you manage the VOLUME, VELOCITY & VARIABILITY of complex data streams in order to find

More information

OpenVMS Support for c-class Blades

OpenVMS Support for c-class Blades OpenVMS Support for c-class Blades John Shortt HP OpenVMS Engineering 27-Sep-2007 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice Topics

More information

DD670, DD860, and DD890 Hardware Overview

DD670, DD860, and DD890 Hardware Overview DD670, DD860, and DD890 Hardware Overview Data Domain, Inc. 2421 Mission College Boulevard, Santa Clara, CA 95054 866-WE-DDUPE; 408-980-4800 775-0186-0001 Revision A July 14, 2010 Copyright 2010 EMC Corporation.

More information

Arrow ECS sp. z o.o. Oracle Partner Academy training environment with Oracle Virtualization. Oracle Partner HUB

Arrow ECS sp. z o.o. Oracle Partner Academy training environment with Oracle Virtualization. Oracle Partner HUB Oracle Partner Academy training environment with Oracle Virtualization Technology Oracle Partner HUB Overview Description of technology The idea of creating new training centre was to attain light and

More information

Servers, Clients. Displaying max. 60 cameras at the same time Recording max. 80 cameras Server-side VCA Desktop or rackmount form factor

Servers, Clients. Displaying max. 60 cameras at the same time Recording max. 80 cameras Server-side VCA Desktop or rackmount form factor Servers, Clients Displaying max. 60 cameras at the same time Recording max. 80 cameras Desktop or rackmount form factor IVR-40/40-DSKT Intellio standard server PC 60 60 Recording 60 cameras Video gateway

More information

See BeYonD the LiMitS

See BeYonD the LiMitS SuN S full LINE of INTEGRATED SERVERS, SToRAGE, AND NETWoRKING SYSTEMS See BeYonD the LiMitS Highlights Sun offers a complete portfolio of products that converge servers, storage, software, and networking

More information

PCI Express Impact on Storage Architectures. Ron Emerick, Sun Microsystems

PCI Express Impact on Storage Architectures. Ron Emerick, Sun Microsystems PCI Express Impact on Storage Architectures Ron Emerick, Sun Microsystems SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA. Member companies and individual members may

More information

FUJITSU Enterprise Product & Solution Facts

FUJITSU Enterprise Product & Solution Facts FUJITSU Enterprise Product & Solution Facts shaping tomorrow with you Business-Centric Data Center The way ICT delivers value is fundamentally changing. Mobile, Big Data, cloud and social media are driving

More information

A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing.

A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing. Appro HyperBlade A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing. Appro HyperBlade clusters are flexible, modular scalable offering a high-density

More information

HUAWEI Tecal E6000 Blade Server

HUAWEI Tecal E6000 Blade Server HUAWEI Tecal E6000 Blade Server Professional Trusted Future-oriented HUAWEI TECHNOLOGIES CO., LTD. The HUAWEI Tecal E6000 is a new-generation server platform that guarantees comprehensive and powerful

More information

TS500-E5. Configuration Guide

TS500-E5. Configuration Guide TS500-E5 Configuration Guide E4631 Second Edition V2 March 2009 Copyright 2009 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in it, may

More information

SUN BLADE 6000 CHASSIS

SUN BLADE 6000 CHASSIS SUN BLADE 6000 CHASSIS MODULAR INTEGRATION FOR MAXIMUM EFFICIENCY KEY FEATURES Space efficient 10U form-factor Up to ten single- or dual-node server modules or storage modules Up to 20 PCIe ExpressModules(EMs)

More information

VTrak 15200 SATA RAID Storage System

VTrak 15200 SATA RAID Storage System Page 1 15-Drive Supports over 5 TB of reliable, low-cost, high performance storage 15200 Product Highlights First to deliver a full HW iscsi solution with SATA drives - Lower CPU utilization - Higher data

More information

EDUCATION. PCI Express, InfiniBand and Storage Ron Emerick, Sun Microsystems Paul Millard, Xyratex Corporation

EDUCATION. PCI Express, InfiniBand and Storage Ron Emerick, Sun Microsystems Paul Millard, Xyratex Corporation PCI Express, InfiniBand and Storage Ron Emerick, Sun Microsystems Paul Millard, Xyratex Corporation SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA. Member companies

More information

Fujitsu PRIMERGY Servers Portfolio

Fujitsu PRIMERGY Servers Portfolio Fujitsu Servers Portfolio Complete server solutions that drive your success shaping tomorrow with you Higher IT efficiency and reduced total cost of ownership Fujitsu Micro and Tower Servers MX130 S2 TX100

More information

SPARC T5-1B SERVER MODULE

SPARC T5-1B SERVER MODULE SPARC T5-1B SERVER MODULE KEY FEATURES 16 cores per processor deliver a remarkable 2.3x the system throughput over the previous generation 1.2x single-thread performance increase and double the L3 cache

More information

HUAWEI TECHNOLOGIES CO., LTD. HUAWEI FusionServer X6800 Data Center Server

HUAWEI TECHNOLOGIES CO., LTD. HUAWEI FusionServer X6800 Data Center Server HUAWEI TECHNOLOGIES CO., LTD. HUAWEI FusionServer X6800 Data Center Server HUAWEI FusionServer X6800 Data Center Server Data Center Cloud Internet App Big Data HPC As the IT infrastructure changes with

More information

StorageBox 1000. High Performance NVMe JBOF

StorageBox 1000. High Performance NVMe JBOF High Performance NVMe JBOF The High Capacity, Fastest and Most Modular Direct Attached NVMe Storage Device for VDI and HPC BLAZING 12GB/s SPEED 8 DRIVES [1U ] WORKS WITH ANY SERVER The Magma StorageBox

More information

PCI Express Impact on Storage Architectures and Future Data Centers. Ron Emerick, Oracle Corporation

PCI Express Impact on Storage Architectures and Future Data Centers. Ron Emerick, Oracle Corporation PCI Express Impact on Storage Architectures and Future Data Centers Ron Emerick, Oracle Corporation SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA. Member companies

More information

Tipos de Máquinas. 1. Overview - 7946 x3550 M2. Features X550M2

Tipos de Máquinas. 1. Overview - 7946 x3550 M2. Features X550M2 Tipos de Máquinas X550M2 1. Overview - 7946 x3550 M2 IBM System x3550 M2 Machine Type 7946 is a follow on to the IBM System x3550 M/T 7978. The x3550 M2 is a self-contained, high performance, rack-optimized,

More information

PCI Express and Storage. Ron Emerick, Sun Microsystems

PCI Express and Storage. Ron Emerick, Sun Microsystems Ron Emerick, Sun Microsystems SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA. Member companies and individuals may use this material in presentations and literature

More information

CUTTING-EDGE SOLUTIONS FOR TODAY AND TOMORROW. Dell PowerEdge M-Series Blade Servers

CUTTING-EDGE SOLUTIONS FOR TODAY AND TOMORROW. Dell PowerEdge M-Series Blade Servers CUTTING-EDGE SOLUTIONS FOR TODAY AND TOMORROW Dell PowerEdge M-Series Blade Servers Simplifying IT The Dell PowerEdge M-Series blade servers address the challenges of an evolving IT environment by delivering

More information

INDIAN INSTITUTE OF TECHNOLOGY KANPUR Department of Mechanical Engineering

INDIAN INSTITUTE OF TECHNOLOGY KANPUR Department of Mechanical Engineering INDIAN INSTITUTE OF TECHNOLOGY KANPUR Department of Mechanical Engineering Enquiry No: Enq/IITK/ME/JB/02 Enquiry Date: 14/12/15 Last Date of Submission: 21/12/15 Formal quotations are invited for HPC cluster.

More information

SUN FIRE X4170, X4270, AND X4275 SERVER ARCHITECTURE Optimizing Performance, Density, and Expandability to Maximize Datacenter Value

SUN FIRE X4170, X4270, AND X4275 SERVER ARCHITECTURE Optimizing Performance, Density, and Expandability to Maximize Datacenter Value SUN FIRE X4170, X4270, AND X4275 SERVER ARCHITECTURE Optimizing Performance, Density, and Expandability to Maximize Datacenter Value White Paper April 2009 Abstract In compact 1U and 2U form factors, the

More information

NEC EXPRESS5800/R320c-E4 Configuration Guide

NEC EXPRESS5800/R320c-E4 Configuration Guide NEC EXPRESS5800/R320c-E4 Configuration Guide VMware model Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure

More information

IBM System x family brochure

IBM System x family brochure IBM Systems and Technology System x IBM System x family brochure IBM System x rack and tower servers 2 IBM System x family brochure IBM System x servers Highlights IBM System x and BladeCenter servers

More information

SUN FIRE X4170 SERVER

SUN FIRE X4170 SERVER SUN FIRE X4170 SERVER KEY FEATURES AND BENEFITS ULTIMATE IN ENTERPRISE PERFORMANCE FOR DATABASE MANAGEMENT OR WEB APPLICATIONS FEATURES Your business is under increasing pressure to deliver more services

More information

Hardware & Software Specification i2itracks/popiq

Hardware & Software Specification i2itracks/popiq Hardware & Software Specification i2itracks/popiq 3663 N. Laughlin Rd., Suite 200 Santa Rosa, CA 95403 866-820- 2212 www.i2isys.com 1 I2iSystems Hardware and Software Specifications Revised 04/09/2015

More information

Cisco MCS 7825-H3 Unified Communications Manager Appliance

Cisco MCS 7825-H3 Unified Communications Manager Appliance Cisco MCS 7825-H3 Unified Communications Manager Appliance Cisco Unified Communications is a comprehensive IP communications system of voice, video, data, and mobility products and applications. It enables

More information

Evaluation Report: HP Blade Server and HP MSA 16GFC Storage Evaluation

Evaluation Report: HP Blade Server and HP MSA 16GFC Storage Evaluation Evaluation Report: HP Blade Server and HP MSA 16GFC Storage Evaluation Evaluation report prepared under contract with HP Executive Summary The computing industry is experiencing an increasing demand for

More information

Fujitsu PRIMERGY Servers Portfolio

Fujitsu PRIMERGY Servers Portfolio Fujitsu Servers Portfolio Dynamic Infrastructures for workgroup, datacenter and cloud computing shaping tomorrow with you Higher IT efficiency and reduced total cost of ownership Fujitsu Micro and Tower

More information

H ARDWARE C ONSIDERATIONS

H ARDWARE C ONSIDERATIONS H ARDWARE C ONSIDERATIONS for Sidewinder 5 firewall software Dell Precision 530 This document provides information on specific system hardware required for running Sidewinder firewall software on a Dell

More information

THE SUN STORAGE AND ARCHIVE SOLUTION FOR HPC

THE SUN STORAGE AND ARCHIVE SOLUTION FOR HPC THE SUN STORAGE AND ARCHIVE SOLUTION FOR HPC The Right Data, in the Right Place, at the Right Time José Martins Storage Practice Sun Microsystems 1 Agenda Sun s strategy and commitment to the HPC or technical

More information

Web 2.0 and Preservation Archiving Services Infrastructure. Keith Rajecki Solutions Architect Sun Microsystems, Inc.

Web 2.0 and Preservation Archiving Services Infrastructure. Keith Rajecki Solutions Architect Sun Microsystems, Inc. Web 2.0 and Preservation Archiving Services Infrastructure Keith Rajecki Solutions Architect Sun Microsystems, Inc. 1 Agenda 1. Impact of Web on Organizations 2. Challenges 3. Customer Benefits from Sun

More information

PCIe Over Cable Provides Greater Performance for Less Cost for High Performance Computing (HPC) Clusters. from One Stop Systems (OSS)

PCIe Over Cable Provides Greater Performance for Less Cost for High Performance Computing (HPC) Clusters. from One Stop Systems (OSS) PCIe Over Cable Provides Greater Performance for Less Cost for High Performance Computing (HPC) Clusters from One Stop Systems (OSS) PCIe Over Cable PCIe provides greater performance 8 7 6 5 GBytes/s 4

More information

Windows Server 2008 R2 for Itanium-Based Systems offers the following high-end features and capabilities:

Windows Server 2008 R2 for Itanium-Based Systems offers the following high-end features and capabilities: Overview NOTE: HP no longer sells Microsoft Windows Server 2008/2008 R2 on Integrity servers. HP will continue to support Microsoft Windows Server 2008/2008 R2 until Microsoft's end of mainstream support

More information

Boost Database Performance with the Cisco UCS Storage Accelerator

Boost Database Performance with the Cisco UCS Storage Accelerator Boost Database Performance with the Cisco UCS Storage Accelerator Performance Brief February 213 Highlights Industry-leading Performance and Scalability Offloading full or partial database structures to

More information

QuickSpecs. HP Integrity cx2620 Server. Overview

QuickSpecs. HP Integrity cx2620 Server. Overview Overview At A Glance Product Numbers HP cx2620 Server with one 1.6GHz/3MB single-core CPU AB401A HP cx2620 Server with one 1.4GHz/12MB dual-core AB402A Standard System Features Multiple Operating Environment

More information

How To Configure Your Computer With A Microsoft X86 V3.2 (X86) And X86 (Xo) (Xos) (Powerbook) (For Microsoft) (Microsoft) And Zilog (X

How To Configure Your Computer With A Microsoft X86 V3.2 (X86) And X86 (Xo) (Xos) (Powerbook) (For Microsoft) (Microsoft) And Zilog (X System Configuration and Order-information Guide RX00 S4 February 008 Front View CD-ROM Drive (Optional) Hard Disk Bay Back View PCI Slot 0/00/000BASE-T connector Serial Port Display Mouse Keyboard Inside

More information

HP Cloudline Overview

HP Cloudline Overview HP Cloudline Overview Infrastructure for Cloud Service Providers Dave Peterson Hewlett-Packard Company Copyright 2015 2012 Hewlett-Packard Development Company, L.P. The information contained herein is

More information

System. A Product Concept Introduction ORACLE WHITE PAPER JUNE 2015

System. A Product Concept Introduction ORACLE WHITE PAPER JUNE 2015 System A Product Concept Introduction ORACLE WHITE PAPER JUNE 2015 Table of Contents Introduction 2 Blades Versus Rackmount Servers 3 Traditional Server Architectures Merged 3 Plug-and-Play Integrated

More information

Cisco UCS B200 M3 Blade Server

Cisco UCS B200 M3 Blade Server Data Sheet Cisco UCS B200 M3 Blade Server Product Overview The Cisco Unified Computing System (Cisco UCS ) combines Cisco UCS B-Series Blade Servers and C-Series Rack Servers with networking and storage

More information

Acer AR180 F1 specifications

Acer AR180 F1 specifications Product overview The Acer AR180 F1 dual-socket server delivers solid performance, scale-up flexibility, and optimized storage capacity in a 2U modular form factor. Comprehensive management utilities and

More information

High Performance 2U Storage Server. Mass Storage Capacity in a 2U Chassis

High Performance 2U Storage Server. Mass Storage Capacity in a 2U Chassis High Performance 2U Storage Server Based on the Intel Socket R E5-2600 processor platform, the ASUS RS720-E7/RS12 server offers customers an extensive feature set: mass storage. high memory capacity, outstanding

More information

Fujitsu PRIMERGY BX920 S2 Dual-Socket Server

Fujitsu PRIMERGY BX920 S2 Dual-Socket Server Datasheet Fujitsu PRIMERGY BX920 S2 Dual-Socket Server Blade Datasheet for Red Hat certification Universal Dual-Sockel Server Blade with high computing and I/O performance in a small form factor The PRIMERGY

More information

Primergy Blade Server

Primergy Blade Server Primergy Blade Server (Konsolidace a virtualizace) Petr Matěna Prague, 15.8.2006 Řešení FSC Primergy, VMware, BladeFrame Serverová platforma pro DDC (Dynamic Data Center) Industry Standard servery Mission

More information

Data Sheet Fujitsu PRIMERGY BX920 S2 Dual Socket Server Blade

Data Sheet Fujitsu PRIMERGY BX920 S2 Dual Socket Server Blade Data Sheet Fujitsu PRIMERGY BX920 S2 Dual Socket Server Blade Universal dual socket server blade with high computing and I/O performance in a small form factor The PRIMERGY BX Blade Servers are the ideal

More information

Application Server Platform Architecture. IEI Application Server Platform for Communication Appliance

Application Server Platform Architecture. IEI Application Server Platform for Communication Appliance IEI Architecture IEI Benefits Architecture Traditional Architecture Direct in-and-out air flow - direction air flow prevents raiser cards or expansion cards from blocking the air circulation High-bandwidth

More information

Cisco UCS B-Series M2 Blade Servers

Cisco UCS B-Series M2 Blade Servers Cisco UCS B-Series M2 Blade Servers Cisco Unified Computing System Overview The Cisco Unified Computing System is a next-generation data center platform that unites compute, network, storage access, and

More information

GOLDEN EGGS. ORACLE SUN x86-64 Servers 2P 4P 8P. Westmere-EP Intel Xeon X5680 x64 3330MHz 2P-Six-C. Visual Cook Book for: ORACLE SUN X86-64 Servers

GOLDEN EGGS. ORACLE SUN x86-64 Servers 2P 4P 8P. Westmere-EP Intel Xeon X5680 x64 3330MHz 2P-Six-C. Visual Cook Book for: ORACLE SUN X86-64 Servers Staple here /documents/ge-sun-book-.pdf Visual Cook Book for: SUN X8- Servers 8 - Oracle Fire Family Map Servers: - X-M Intel Xeon P U - X-M Intel Xeon P U - X Intel Xeon P U - X8 Intel Xeon 8P U - X AMD

More information

The Future of Computing Cisco Unified Computing System. Markus Kunstmann Channels Systems Engineer

The Future of Computing Cisco Unified Computing System. Markus Kunstmann Channels Systems Engineer The Future of Computing Cisco Unified Computing System Markus Kunstmann Channels Systems Engineer 2009 Cisco Systems, Inc. All rights reserved. Data Centers Are under Increasing Pressure Collaboration

More information

Cisco MCS 7845-I2 Unified Communications Manager Appliance

Cisco MCS 7845-I2 Unified Communications Manager Appliance Cisco MCS 7845-I2 Unified Communications Manager Appliance Cisco Unified Communications is a comprehensive IP communications system of voice, video, data, and mobility products and applications. It enables

More information

Unified Computing Systems

Unified Computing Systems Unified Computing Systems Cisco Unified Computing Systems simplify your data center architecture; reduce the number of devices to purchase, deploy, and maintain; and improve speed and agility. Cisco Unified

More information

Cisco Unified Communications on the Cisco Unified Computing System

Cisco Unified Communications on the Cisco Unified Computing System Cisco Unified Communications on the Cisco Unified Computing System Cisco is introducing software application versions from the Cisco Unified Communications portfolio (Versions 8.0(2) and later) that are

More information

The Bus (PCI and PCI-Express)

The Bus (PCI and PCI-Express) 4 Jan, 2008 The Bus (PCI and PCI-Express) The CPU, memory, disks, and all the other devices in a computer have to be able to communicate and exchange data. The technology that connects them is called the

More information

SUN SERVER X4-2L SYSTEM

SUN SERVER X4-2L SYSTEM SUN SERVER X4-2L SYSTEM KEY FEATURES 2U enterprise-class server with flexible storage options Intel Xeon processor E5-2600 v2 product family CPUs Sixteen DIMM slots Six PCIe 3.0 slots Four 10GBase-T ports

More information

FLOW-3D Performance Benchmark and Profiling. September 2012

FLOW-3D Performance Benchmark and Profiling. September 2012 FLOW-3D Performance Benchmark and Profiling September 2012 Note The following research was performed under the HPC Advisory Council activities Participating vendors: FLOW-3D, Dell, Intel, Mellanox Compute

More information

Cisco UCS B440 M2 High-Performance Blade Server

Cisco UCS B440 M2 High-Performance Blade Server Data Sheet Cisco UCS B440 M2 High-Performance Blade Server Product Overview The Cisco UCS B440 M2 High-Performance Blade Server delivers the performance, scalability and reliability to power computation-intensive,

More information

High Performance 1U Server. High Performance 1U Storage Server. Front Parallel CPU Design features better cooling

High Performance 1U Server. High Performance 1U Storage Server. Front Parallel CPU Design features better cooling High Performance 1U Server The ASUS RS700-E7/RS8 1U server is based on dual Intel Socket R series processors (135W), designed with 24 DIMM slots to support up to 512GB memory. It features an optimized

More information

MESOS CB220. Cluster-in-a-Box. Network Storage Appliance. A Simple and Smart Way to Converged Storage with QCT MESOS CB220

MESOS CB220. Cluster-in-a-Box. Network Storage Appliance. A Simple and Smart Way to Converged Storage with QCT MESOS CB220 MESOS CB220 Cluster-in-a-Box Network Storage Appliance A Simple and Smart Way to Converged Storage with QCT MESOS CB220 MESOS CB220 A Simple and Smart Way to Converged Storage Tailored for SMB storage

More information

SAN TECHNICAL - DETAILS/ SPECIFICATIONS

SAN TECHNICAL - DETAILS/ SPECIFICATIONS SAN TECHNICAL - DETAILS/ SPECIFICATIONS Technical Details / Specifications for 25 -TB Usable capacity SAN Solution Item 1) SAN STORAGE HARDWARE : One No. S.N. Features Description Technical Compliance

More information

SUN ORACLE EXADATA STORAGE SERVER

SUN ORACLE EXADATA STORAGE SERVER SUN ORACLE EXADATA STORAGE SERVER KEY FEATURES AND BENEFITS FEATURES 12 x 3.5 inch SAS or SATA disks 384 GB of Exadata Smart Flash Cache 2 Intel 2.53 Ghz quad-core processors 24 GB memory Dual InfiniBand

More information

SUN SERVER X3-2L. Sun Server X3-2L server is the perfect integration of compute and storage in a single 2U enclosure for clustered

SUN SERVER X3-2L. Sun Server X3-2L server is the perfect integration of compute and storage in a single 2U enclosure for clustered SUN SERVER X3-2L KEY FEATURES 2U enterprise-class server with flexible storage options Two Intel Xeon processor E5-2600 product family CPUs Sixteen dual inline memory module (DIMM) slots supporting two

More information

Cisco 7816-I5 Media Convergence Server

Cisco 7816-I5 Media Convergence Server Cisco 7816-I5 Media Convergence Server Cisco Unified Communications Solutions unify voice, video, data, and mobile applications on fixed and mobile networks, enabling easy collaboration every time from

More information

IBM System x family brochure

IBM System x family brochure IBM Systems and Technology System x IBM System x family brochure IBM System x rack, BladeCenter and tower servers 2 IBM System x family brochure Highlights IBM System x and BladeCenter servers help deliver

More information

Sun in HPC. Update for IDC HPC User Forum Tucson, AZ, Sept 2008

Sun in HPC. Update for IDC HPC User Forum Tucson, AZ, Sept 2008 Sun in HPC Update for IDC HPC User Forum Tucson, AZ, Sept 2008 Bjorn Andersson Director, HPC Marketing Makia Minich Lead Architect, Sun HPC Software, Linux Edition Sun Microsystems Core Focus Areas for

More information

HUAWEI Tecal E9000 Converged Infrastructure Blade Server

HUAWEI Tecal E9000 Converged Infrastructure Blade Server E9000 Converged Infrastructure Blade Server Professional Trusted Future-oriented HUAWEI TECHNOLOGIES CO., LTD. The E9000 is a new-generation blade server that integrates computing, storage, switching,

More information

SPARC T4-1 Server. Product Overview

SPARC T4-1 Server. Product Overview O R A C L E D A T A S H E E T SPARC T4-1 Server Oracle s SPARC T4 servers running Oracle Solaris deliver outstanding performance while offering a highly scalable secure and integrated environment optimized

More information

5520UR 00UR 00UR 625UR 625URSAS 00UR URBRP 600URLX 625URLX

5520UR 00UR 00UR 625UR 625URSAS 00UR URBRP 600URLX 625URLX Intel Server Board S5520 5520UR Intel Server System SR600 00UR Intel Server System SR600 00UR URHS Intel Server System SR625UR Intel Server System SR625UR 625URSAS Intel Server System SR2600 00UR URBRP

More information

HP Moonshot System. Table of contents. A new style of IT accelerating innovation at scale. Technical white paper

HP Moonshot System. Table of contents. A new style of IT accelerating innovation at scale. Technical white paper Technical white paper HP Moonshot System A new style of IT accelerating innovation at scale Table of contents Abstract... 2 Meeting the new style of IT requirements... 2 What makes the HP Moonshot System

More information

Data Sheet Fujitsu PRIMERGY CX122 S1 Cloud server unit for PRIMERGY CX1000

Data Sheet Fujitsu PRIMERGY CX122 S1 Cloud server unit for PRIMERGY CX1000 Data Sheet Fujitsu PRIMERGY CX122 S1 Cloud server unit for PRIMERGY CX1000 Datasheet for Red Hat certification PRIMERGY CX1000 is a new product category within the PRIMERGY x86 server family. Its focus

More information

Minimum Hardware Specifications Upgrades

Minimum Hardware Specifications Upgrades Minimum Hardware Specifications Upgrades http://www.varian.com/hardwarespecs ARIA for Medical Oncology, & ARIA for Radiation Oncology Version 13.0 1 ARIA Version 13.0 Minimum Hardware Specifications Minimum:

More information

HP recommended configuration for Microsoft Exchange Server 2010: HP LeftHand P4000 SAN

HP recommended configuration for Microsoft Exchange Server 2010: HP LeftHand P4000 SAN HP recommended configuration for Microsoft Exchange Server 2010: HP LeftHand P4000 SAN Table of contents Executive summary... 2 Introduction... 2 Solution criteria... 3 Hyper-V guest machine configurations...

More information

Acer AT110 F2 Specifications

Acer AT110 F2 Specifications Product overview The AT110 F2 delivers true server-class features and expandability along with best price-performance technology to assure the success of your small-sized business. This single-socket tower

More information

Oracle Exadata: The World s Fastest Database Machine Exadata Database Machine Architecture

Oracle Exadata: The World s Fastest Database Machine Exadata Database Machine Architecture Oracle Exadata: The World s Fastest Database Machine Exadata Database Machine Architecture Ron Weiss, Exadata Product Management Exadata Database Machine Best Platform to Run the

More information

Cisco Unified Computing System and EMC VNXe3300 Unified Storage System

Cisco Unified Computing System and EMC VNXe3300 Unified Storage System Cisco Unified Computing System and EMC VNXe3300 Unified Storage System An Ideal Solution for SMB Server Consolidation White Paper January 2011, Revision 1.0 Contents Cisco UCS C250 M2 Extended-Memory Rack-Mount

More information

Summary. Key results at a glance:

Summary. Key results at a glance: An evaluation of blade server power efficiency for the, Dell PowerEdge M600, and IBM BladeCenter HS21 using the SPECjbb2005 Benchmark The HP Difference The ProLiant BL260c G5 is a new class of server blade

More information

Acer AT350 F1 specifications

Acer AT350 F1 specifications Product overview The Acer AT350 F1 is a dual-socket tower or 4U rack mountable server for flexible environment delivering blazing performance and exceptional expansion capability. Offering high reliability,

More information

Brainlab Node TM Technical Specifications

Brainlab Node TM Technical Specifications Brainlab Node TM Technical Specifications BRAINLAB NODE TM HP ProLiant DL360p Gen 8 CPU: Chipset: RAM: HDD: RAID: Graphics: LAN: HW Monitoring: Height: Width: Length: Weight: Operating System: 2x Intel

More information

præsentation oktober 2011

præsentation oktober 2011 Johnny Olesen System X presale præsentation oktober 2011 2010 IBM Corporation 2 Hvem er jeg Dagens agenda Server overview System Director 3 4 Portfolio-wide Innovation with IBM System x and BladeCenter

More information

How To Write An Article On An Hp Appsystem For Spera Hana

How To Write An Article On An Hp Appsystem For Spera Hana Technical white paper HP AppSystem for SAP HANA Distributed architecture with 3PAR StoreServ 7400 storage Table of contents Executive summary... 2 Introduction... 2 Appliance components... 3 3PAR StoreServ

More information

Cost Efficient VDI. XenDesktop 7 on Commodity Hardware

Cost Efficient VDI. XenDesktop 7 on Commodity Hardware Cost Efficient VDI XenDesktop 7 on Commodity Hardware 1 Introduction An increasing number of enterprises are looking towards desktop virtualization to help them respond to rising IT costs, security concerns,

More information

Part-1: SERVER AND PC

Part-1: SERVER AND PC Part-1: SERVER AND PC Item Item Details Manufacturer Quantity Unit Price Total Dell server or equivalent Intel Xeon E5-2420 1.90GHz, 15M Cache, 7.2GT/s QPI, Turbo, 6C, 95W or equivalent PCIE Riser for

More information

Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server

Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server Blade Made Easy Fujitsu PRIMERGY BX Blade Servers provide a faster, simpler and lower-cost way to build and run an IT infrastructure in your midsize organization,

More information

Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and Dell PowerEdge M1000e Blade Enclosure

Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and Dell PowerEdge M1000e Blade Enclosure White Paper Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and Dell PowerEdge M1000e Blade Enclosure White Paper March 2014 2014 Cisco and/or its affiliates. All rights reserved. This

More information

Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and IBM FlexSystem Enterprise Chassis

Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and IBM FlexSystem Enterprise Chassis White Paper Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and IBM FlexSystem Enterprise Chassis White Paper March 2014 2014 Cisco and/or its affiliates. All rights reserved. This document

More information