Blood Collection Systems

Size: px
Start display at page:

Download "Blood Collection Systems"

Transcription

1 Blood Collection Systems As individual as your patients The complete solution for any requirement

2 SARSTEDT International Your Partner in medicine and science worldwide

3 Table of Contents The SARSTEDT Group The Company Foundation and History 4-5 S-Monovette The Progressive Blood Collection System 6-9 S-Monovette The revolution in blood collection 7 Engineered safety The flexible system 8 S-Monovette Aspiration & vacuum method 9 S-Monovette Convincing Arguments for a Safe System S-Monovette & Safety-Needle / Safety-Multifly A safe, secure combination 10 Safety-Needle Safety for routine blood collection 11 Safety-Multifly Safety for fragile veins 11 S-Monovette Convincing arguments for a safe system S-Monovette Range of Sizes and Preparations S-Monovette Colour code 15 S-Monovette for special analyses & S-Sedivette Blood gas analytics S-Monovette Paediatrics Reduced Discomfort with Minimal Sample Volumes S-Monovette ml 21 Neonatal Needle & Prepared Micro Tubes S-Monovette Adapters & Accessories for Safe Blood Collection Sarstedt Instruments System solutions for optimal sample processing 26 Extract from overall laboratory instrument range 27 Capillary Blood Collection Designed for Individual Requirements Individuality requires flexible systems 29 Microvette Multivette 600 and Microvette CB 200 ESR 32 Safety-Lancet 33 Disposal, Mailing and Transport Systems, Sample Handling Disposal, sample mailing & transport 34 Extract from range of accessories 35 V-Monovette V-Monovette The vacuum blood collection system for transfusion medicine 36 Extract from range of transfusion medicine products 37 Service & Technical Support Assistance directly on Site at your Facility

4 The SARSTEDT Group The Company Foundation and History Growth means progress

5 The SARSTEDT Group The Company Foundation and History Growth means progress Ever since the company was established in 1961, progress has been a key motivation. Today, the SARSTEDT Group is a global company with 13 production facilities in Europe, North America and Australia and a workforce of 2,500. For decades, research and purpose-oriented product development using innovative technologies along with constant communication with the user have been decisive factors in establishing SARSTEDT as a leading supplier of laboratory and diagnostic products. Quality from one source from the product idea to the customer From product development and production to marketing and sales all our services come from one source. PRODUCT DEVELOPMENT at our R&D centre is based on collaboration with the users and state-of-the-art technologies from the idea to the final product. More than 90% of all our products are manufactured with high-tech equipment at company-owned PRODUCTION sites in Germany and abroad. Our products are used directly with patients and must, therefore, meet a high QUALITY STANDARD. To comply with this requirement, we can rely on a progressive, integrated Quality Management System in accordance with EN ISO 9001 and EN ISO International MARKETING & SALE of Sarstedt products is primarily ensured via our own 29 sales organisations. In addition, a worldwide network of dealers attends to our customers needs. Our team of competent medical device specialists provides optimum support and SERVICE. 5

6 S-Monovette The Progressive Blood Collection System It s the individual that matters

7 S-Monovette The Revolution in Blood Collection Open system Aspiration technique Enclosed system + Vacuum technique = One system 2 techniques The S-Monovette combines the advantages of both systemsstems Suitable for all vein conditions Optimal sample quality Economical Safe 7

8 Engineered Safety The Flexible System It s the individual that matters Demographic development shows that our population is growing older which places a very specific demand on medical care and treatment. Blood collection in particular is affected because difficult vein conditions are increasingly noted with elderly patients. Blood collection may also be complicated from children with very small or fragile veins. The answer to all these challenges is the S-Monovette with its variable collection techniques combined in one system. As required, phlebotomists can select either the aspiration or the vacuum method. We already know that 47.3%* of all patients are under 5 years, or over 65 years. * Association of German Hospitals Zahlen, Daten, Fakten 2009 This shows that gentle blood collection is essential for maintaining optimal results. Aspiration method... the gentle technique for routine blood collection The aspiration technique is the method of choice for gentle blood collection from any vein condition and is ideal for fragile veins at risk to collapse. Vacuum method... always a fresh vacuum Using the S-Monovette with the vacuum technique ensures that a fresh vacuum is generated immediately prior to blood collection, providing a precise filling volume as with the aspiration method. 8

9 S-Monovette Aspiration & Vacuum Method Aspiration method 1 The S-Monovette and Safety-Needle are assembled immediately prior to blood collection. Venipuncture to follow. 2 Slowly withdrawing the plunger ensures gentle blood flow. For multiple sampling, the next S-Monovettes are connected to the Safety-Needle and samples collected as described. 3 When blood collection is complete, the last S-Monovette is removed from the Safety-Needle and the needle withdrawn from the vein. 4 For enhanced security during transport and centrifugation, the piston is locked in the base of the S-Monovette and the plunger broken off. Vacuum method 1 Locking the piston in the base of the S-Monovette ensures a fresh vacuum immediately prior to blood collection. The plunger is broken off. 2 Immediately prior to blood collection, the vein is punctured with the Safety-Needle or Safety Multifly. 3 The evacuated S-Monovette is assembled with the Safety-Needle located in the vein and filled. For multiple sampling, the next evacuated S-Monovettes are connected to the Safety-Needle and samples collected as described. 4 When blood collection is complete, the last S-Monovette is detached from the Safety-Needle/Safety-Multifly and the needle withdrawn from the vein. 9

10 S-Monovette Convincing Arguments for a Safe System S-Monovette & Safety-Needle/Safety-Multifly A safe, secure combination The Safety-Needle or Safety- Multifly needle is safely and securely connected to the S-Monovette by a 3-pin locking mechanism. 10

11 Safety-Needle Safety for routine blood collection The Safety-Needle is always ready for use. No need to assemble it with a needle holder. Only pre-assembled systems like the S-Monovette Safety-Needle provide efficient protection against the risk of exposure likely to be caused by contaminated, re-used needle holders. Re-use of the needle holder is excluded. Safe puncturing... at a recommended low angle particularly for fragile veins. Safety needle protector The special needle protector of the Safety-Needle enables safe completion of blood collection by locking the needle in the protective sleeve. Subsequently, the complete unit is disposed of in a suitable sharps container. Safety-Multifly Safety for fragile veins Pre-assembled adapter The S-Monovette adapter of the Safety-Multifly is already assembled forming a complete unit ready for use. Optimal packaging and material The packaging and tubing are tailored to the requirements of blood collection and subsequent disposal in sharps containers. The kink-proof tubing enables trouble-free venipuncture and safe disposal in a sharps container. 11

12 S-Monovette Convincing Arguments for a Safe System Visible control of successful venipuncture The first blood drop immediately enters the S-Monovette upon successful venipuncture with the assembled Safety-Needle, so the phlebotomist can be sure that the vein has been punctured. Cost savings from haemolysis rate reduction Studies* reveal that gentle aspiration of the blood sample as is possible using the S-Monovette or a disposable syringe enables reduced haemolysis rates compared to blood collection with vacuum systems only. Strongly haemolytic samples, in particular, provide erroneous laboratory results requiring repeat sampling. With the S-Monovette system, haemolysis rates can be reduced, resulting in the following decisive benefits: Reduced expenditure in time and labour costs Reduced material cost No additional reagent cost Sample without haemolysis Strongly haemolytic sample * Influence of the serum collection system on hemolysis, Apr. Truus Goegebuer, Apr.-Bioloog Johan Debrabandere, Clinical Laboratory, H.-Hartziekenhuis Roeselare-Menen, Focus Diagnostica, Vol. 16, No. 2, 2008, und Reducing Blood Sample Hemolysis at a Tertiary Hospital Emergency Department, Marcus Eng Hock Ong, MBBS, MPH, Yiong Huak Chan, PhD, Chin Siah Lim, MBBS, The American Journal of Medicine, Vol. 122, No. 11, November

13 Cost savings using the Safety-Needle 140 Safety-Needles of the S-Monovette system fit into a Multi-Safe disposal box. In comparison, five times the number of disposal boxes are needed to discard the same quantity of needles from vacuum systems. Consequently, using the S-Monovette system involves significantly reduced disposal costs. Apart from the cost savings, the system also serves to decrease waste for an improved eco-balance. S-Monovette Vacuum system 140 = 1 box 140 = 5 boxes Packaging User-friendly box packaging for environment-conscious disposal Space-saving storage thanks to compact packaging of 50 pcs. per box The flat, collapsible S-Monovette box significantly reduces the waste volume 5 times higher waste volume of vacuum system packaging 13

14 S-Monovette A Range of Sizes and Preparations Colour codes that suit your requirements

15 S-Monovette Colour code Colour codes that suit your requirements According to EN 14820, single-use containers for human venous specimen collection, an international agreement regarding a particular colour code is not in effect at the moment. Accordingly, Sarstedt provides both the EU and US colour code to accommodate your individual requirements! EU Code US Code Serum (Clotting Activator) S-Monovettes contain beads coated with a clotting activator (silicate). As a rule, this clotting additive enables the blood to clot within 20 to 30 minutes and the sample can be centrifuged. The beads form a layer between the blood clot and serum during centrifugation. Serum-Gel (Clotting Activator) In addition to the beads, this S-Monovette contains a polyacrylic ester gel that, due to its density, forms a stable separating layer between the blood clot and the serum during centrifugation and serves as a barrier during sample transport and storage. Compliance with the recommended storage conditions will keep most parameters stable for up to 48 hours. Plasma / Plasma-Gel (Lithium Heparin) Heparin, at an average concentration of 16 I.U./ml, is used as an anticoagulant for plasma generation. Heparin is coated onto beads which form a layer between the plasma and the corpuscular components during centrifugation. The function of the plasma gel is identical to serum-gel. Haematology (Potassium EDTA) EDTA K 3 is pre-dosed as a liquid preparation in an average concentration of 1.6 mg EDTA/ml blood. The maximum dilution caused by the liquid preparation is lower than 1%. Although the EDTA preparation may dry during storage, this does not in any way impair its anticoagulant effect. An S-Monovette with EDTA K 2 and gel is available for use in molecular virus diagnostics. Glucose Determination (Fluoride) The S-Monovette for glucose determination contains fluoride (1.0 mg/ml blood) as a glycolysis inhibitor and EDTA (1.2 mg/ml blood) as an anticoagulant in a liquid preparation. The glucose concentration in the sample is stabilised for a period of 24 hours. Coagulation (Sodium Citrate) Citrate, pre-dosed as a molar solution (equivalent to 3.2% trisodium citrate), is used for all physiological coagulation studies (e.g. Quick, PTT, TZ, Fibrinogen). A mixing ratio of 1:10 (1 part citrate + 9 parts blood) must be strictly observed. ESR (Sodium Citrate) Citrate, pre-dosed as a trisodium citrate molar solution is used for ESR determination. A mixing ratio of 1:5 (1 part citrate + 4 parts blood) must be strictly observed. For ESR, we recommend the S-Monovette Sediplus system (Westergren method) or the enclosed S-Sedivette system (modified Westergren method). 15

16 Special S-Monovette & S-Sedivette S-Monovette ThromboExact... for suspected pseudothrombocytopenia Pseudothrombocytopenia, a preanalytical phenomenon, describes an erroneously low thrombocyte count. Generally, pseudothrombocytopenia is caused by thrombocyte aggregation. Early detection of this phenomenon ensures that the diagnostic and therapeutic consequences of a thrombocytopenia misdiagnosis are avoided. The S-Monovette ThromboExact has been approved to prevent the formation of thrombocyte aggregation. Apart from the most common aggregation caused by EDTA, multiple aggregation (e.g. heparin and/ or citrate) has also been documented. A correct thrombocyte count is possible for up to 12 hours after blood collection. S-Monovette Homocysteine Z-Gel... for homocysteine determination Correct preanalytical conditions are critical for homocysteine determination because erythrocytes continue to produce homocysteine in the sample after blood collection. Non-stabilised homocysteine diffuses into the plasma leading to a significant increase in homocysteine concentration of approximately 10%/h in the sample material. A specially developed d stabiliser keeps the homocysteine concentration relatively constant for up to eight hours after blood collection at room temperature. Centrifugation of the blood sample within this 8-hour period results in an inert gel barrier that safely separates the serum from the blood clot, ensuring further stability of the homocysteine values for a total of 96 hours. S-Monovette for metal analysis (Lithium-Heparin)... for trace element determination In combination with a special S-Monovette needle, this S-Monovette is ideally suited for analysis of the most commonly found trace elements. The following maximum values in ng/system are defined for the combined system of the empty S-Monovette and needle: TI: 2.5 Pb: 5 Mn: 10 Cd: 1.5 Fe: 50 Al: 40 Ni: 8.0 Cu: 70 Se: 10 Cr: 5.0 Zn: 70 Hg: 10 16

17 S-Monovette for thrombocyte function diagnostics S-Monovette Hirudin Platelet inhibitors (e.g. aspirin) are used to reduce the risk of thrombosis for hospitalised patients after surgery and also for a multitude of therapies for out-patients. To monitor the efficiency (response/non-response) of a platelet inhibiting pharmaceutical drug, either during its development, in routine therapy, or to prove or exclude disorders in thrombocyte function, hirudin has become the anticoagulant of choice. Unlike citrate or heparin, hirudin prevents blood clotting by direct thrombin inhibition, enabling thrombocyte function diagnostics in a native condition. The new S-Monovette Hirudin has been developed in cooperation with Dynabyte/Verum Diagnostica to measure thrombocyte activity on the Multiplate (multiple platelet function analyser). S-Monovette PFA The PFA 100 measuring system from Siemens requires a special, buffered citrate te for precise thrombocyte function analysis. The preparation of the S-Monovette PFA with a 3.8% citrate buffer (0.129 mol/l) and a ph of 5.5 was speciallyly designed to comply with these requirements. With its unique colour code, the S-Monovette PFA is clearly distinguished from standard ard citrate tubes for routine diagnostics. S-Sedivette... for ESR measurement The S-Sedivette is an enclosed, hygienic system made from a break-resistant plastic material specially designed for ESR measurement. ESR is determined in the closed collection tube itself to exclude any further processing steps or products (sedimentation pipette). 17

18 Blood Gas Analytics Collection systems for arterial, venous and capillary sampling The choice of collection techniques enables safe and hygienic blood collection from any patient and for any application. Venous and arterial sampling The Blood Gas Monovette is available in 1 and 2 ml options and has been designed for venous and arterial blood collection. The Ca +2 balanced heparin preparation is also ideal for electrolyte analysis. The Blood Gas Monovette is pre-dosed with liquid heparin enabling swift and thorough mixing of the blood and anticoagulant. (Refer to the study: Clinica Chimica Acta 395 (2008) 187, Elsevier B.V., journal homepage: clinchim) 1 ml option 2 ml option The Blood Gas Monovette is also available with a preassembled membrane adapter! 18

19 Capillary blood collection and accessories Reliable measuring results A distinctive plastic material with low gas permeability and coated with a special Ca 2+ balanced heparin ensure correct measuring results. A unique surface treatment enables swift filling of the capillaries. Sampling is facilitated and the risk of coagulation reduced. Safe sampling The break-proof plastic material prevents injuries and infection hazards for users. Caps A range of cap sizes ensures correct and secure closure of capillaries with different outer diameters. Mixing wire and magnet The convenient cone-shaped magnet moves the mixing wire inside the capillary for optimal mixing of the sample material with the anticoagulant. 19

20 S-Monovette Paediatrics Reduced Discomfort with Minimal Sample Volumes For special requirements in paediatrics

21 S-Monovette ml For special requirements in paediatrics The blood collection system for individual requirements in paediatrics Blood collection in paediatrics calls for skilled phlebotomists and specialised collection systems. As the sensitivity of modern analyser systems increases, the minimum sample volume required for routine tests can be reduced. With its novel design of reduced dimensions and low nominal volume the S-Monovette Paediatrics can accommodate these specific requirements. 1.1 ml Aspiration principle i The aspiration principle permits gentle blood collection (see p. 9) so that the S-Monovette ovette Paediatrics fully complies with the requirements imposed by critical vein conditions in paediatrics. Carrier tube A carrier tube is available for the S-Monovette Paediatrics for direct adaptation in all standard analyser systems and centrifuges. 21

22 Neonatal Needle & Prepared Micro Tubes Patient-friendly blood collection from neonates and premature babies The new Neonatal Needle eliminates the awkward processing step of breaking off the Luer adapter from Luer needles. The design has been specifically tailored for the venipuncture requirements of neonates and premature babies. With its ridged grip, the Neonatal Needle provides secure needle control and can be turned by 360. The exceptional needle quality and unobstructed opening enables ample blood flow using the gravity flow principle. Neonatal Needle optimum handling and flow characteristics Neonatal Needle User Guide Detach protective cap. 1 Remove Neonatal Needle from protective sleeve. 2 Perform venipuncture. Drip blood into a prepared micro tube. 3 Discard Neonatal Needle into a suitable sharps container. 4 22

23 Prepared Micro Tubes Prepared micro tubes are ideally combined with the Neonatal Needle to accommodate blood collected from infants or premature babies. With a low nominal volume and small size, these tubes are perfect for this type of blood collection. An extensive range of preparations is available. Micro Tubes with looped push cap The looped push cap is convenient for single-handed use. The transparent label enables visual control of the filling volume during blood collection. On request, the tubes are also available with a paper label. Screw Cap Micro Tubes The leak-resistant screw cap closure with O-ring in combination with the robust polypropylene tube exceeds transport and storage requirements. Alternatively, a screw cap with integral membrane is available for direct adaptation to analysers. Carrier tube A carrier tube is available for the prepared micro tubes for adaptation in all standard analyser systems and centrifuges. 23

24 Adapters & Accessories for Safe Blood Collection Colour coded cap rings Cap rings in a range of colours are available to identify STAT samples from ambulances, ICUs, and operating theatres, and to improve laboratory organization. With their colour code, these samples can be easily identified on receipt in the lab to prioritise processing. Membrane Adapter The membrane adapter enables the safe adaptation of the Safety-Needle and the Safety-Multifly needle to a Luer system like the Blood Gas Monovette. Multi-Adapter The Multi-Adapter is available as a Luer and Luer-Lock option for adaption of the S-Monovette to all Luer systems like indwelling cannulas, threeway stopcocks or butterfly needles. 24

25 Seraplas V The Seraplas V separates serum/plasma from the blood clot/cells after centrifugation. Haemo-Diff The Haemo-Diff is an adapter that can be attached to the S-Monovette to perform blood smears. From blood collection through the smear, the S-Monovette remains safely closed. The Haemo-Diff provides an adequate blood droplet and optimal smear for reliable analysis results. Tourniquet The tourniquet is conveniently designed for single-handed use and safe blood collection, and is also available in a latex-free version. 25

26 Sarstedt Instruments System solutions for optimal sample processing Sarstedt offers a comprehensive range of instruments for pre- and postanalytics. The system solutions illustrated below provide an initial overview on our overall laboratory instrument range. Please order our separate brochures and flyers for further information. Laboratory Automation The Sarstedt range includes automated systems for pre- and postanalytics. From stand-alone re- and decapper units to large modular sample distributors, we provide individual solutions tailored to the laboratory space and customer requirements. 26

27 Extract from overall Laboratory Instrument Range Centrifuges In medical laboratories, the quality of analysis results decisively depends on the quality of preanalytics. Our space-saving and cost-effective centrifuges enable direct centrifugation at the draw station. ESR Systems In combination with the S-Sedivette ESR system, the automated measuring instruments ensure convenient and reliable determination of the erythrocyte sedimentation rate. The digital multi-function display enables easy reading of the measuring values. Mixers A range of mixers is available for preparation of the blood samples in the various sample tubes. Please order our separate brochures and flyers for further information. 27

28 Capillary Blood Collection Designed for Individual Requirements Individuality requires flexible systems

29 Capillary Blood Collection Individuality requires flexible systems The particular requirements of capillary blood collection shaped the development of our capillary blood collection systems. The individual requirements posed by any group of patients infants, adults and elderly patients call for functional and flexible collection systems. Sarstedt s innovative capillary blood collection systems, the Microvette, Multivette and Safety-Lancet, meet these challenges. See for yourself how our systems can meet all of your requirements. 29

30 Microvette The simple capillary blood collection system Microvette 100/200 Depending on your requirements, the Microvette 100/200 is available with a cylindrical or conical inner tube and in 100 and 200 μl volumes. For both versions, the End-to-End capillary for blood collection is already pre-assembled. The Microvette 100/200 provides all the advantages of a progressive capillary blood collection system: Assembled capillary for blood collection using the End-to-End principle Collection is also possible without the capillary Twist cap is easy to open and minimises aerosol effect Colour-coded cap and print for visual identification of the preparation and volume control Supplied in a convenient stack pack The twist cap design minimises the aerosol effect when opening the tube and ensures a secure closure. Microvette 100/200 User Guide Microvette 100/200 blood collection with assembled End-to-End capillary 30

31 Microvette 300/500 The tubes are ideal for blood collection using the gravity-flow principle with any part of the rim. The unique conical design of the Microvette 300 s inner tube enables thorough mixing even with small blood volumes. The Microvette 300/500 offers the following advantages: Choice of different inner tube designs with 300 μl or 500 μl volume capacity and corresponding graduation Twist cap is easy to open and minimises aerosol effect Cylindrical outer tube is ideal for barcode or patient label Cap can be conveniently attached to the tube base during blood collection to avoid mix-up or loss The conical design of the Microvette 300 s inner tube maximises serum/plasma recovery for pipetting after centrifugation, even with small blood volumes. The shelf life and lot number are printed on each Microvette Microvette 300/500 User Guide Microvette 300/500 blood collection using the tube rim 31

32 Multivette 600 and Microvette CB 200 ESR Capillary and venous blood collection in one system Multivette 600 The flexible Multivette 600 blood collection system can be used for both capillary and venous blood collection. For single venous blood collection, a Luer needle is attached to the capillary tube of the Multivette. The innovative design allows unassisted filling of the inner tube exclusively through venous pressure. Capillary blood is collected using the End-to-End principle. The capillary tube accommodates a capillary blood volume of 600 μl. Multivette 600 User Guide Venous blood collection with a Luer needle Capillary blood collection using the End-to-End principle Microvette CB 200 ESR The Microvette CB 200 ESR is ideal for measuring ESR from capillary blood specimens. The Microvette CB 200 ESR is pre-dosed with citrate and is supplied with an enclosed cap pre-assembled with a prepared End-to-End collection capillary, and a sedimentation capillary. Relevant studies confirm comparative values using the Westergren method. The low sample volume of 200 μl minimises patient discomfort. The graduated ESR rack with 10 measuring stations is specifically designed for use with the Microvette CB 200 ESR. 32

33 Safety-Lancet Safety-Lancet The new generation Safe and easy sampling with increased patient comfort The Safety-Lancet ensures optimal safety for both the patient and user. The needle or blade is safely concealed in the lancet body before and after use, preventing the risk of needlestick injury and cross-infection. User-friendly sampling The system is primed, ready for use and easy to handle. The secure firing button prevents accidental activation and inactivation. With its ridged, flat body, the Safety-Lancet ensures a safe grip. Its small contact face provides for precise puncturing. Patient comfort For reduced patient discomfort, the ultra-sharp, siliconised blades and triple-sharpened needlepoints minimise pain. The controlled penetration depth of the Safety-Lancet eliminates the risk of bone injury. Safety-Lancet User Guide Twist the cap a quarter turn until it separates from the Safety-Lancet. Press the Safety-Lancet firmly against the chosen and cleaned puncture site and press the firing button. Dispose of the Safety-Lancet into a suitable sharps container. 33

34 Entsorgung, Disposal, Mailing Versand- Transport und Transportsysteme, Systems, Sample Probenhandling Handling Disposal, sample mailing & transport In addition to our blood collection systems, Sarstedt offers a targeted range of storage and disposal solutions to streamline blood collection procedures. This range is complemented by products for sample handling, processing, and transport. Please order our separate brochures and flyers for further information. Multi-Safe disposal boxes The Multi-Safe disposal boxes are ideal for safe and user-friendly disposal of pointed, sharp and hazardous objects both for hospital and ambulatory use. Safety-Tray The convenient Safety-Tray helps organise supplies for the complete blood collection procedure. Dedicated storage of accessories streamlines the workflow. The Safety-Tray is designed to accommodate all components required for blood collection from the S-Monovette rack to the Multi-Safe disposal box. 34

35 Extract from Range of Accessories Transport Case and Mailing Box The transport cases and mailing boxes are designed and approved for the safe transport of biological specimens of category B, class UN 3373, in accordance with the P 650 packaging regulations. The transport case is available with a wide aperture or plastic bag with clip. The mailing box securely accommodates mailing containers and bottles with a range of dimensions. It is available in three sizes. S-Monovette Rack The universal block rack with and without handle is ideal for space-saving sample backup storage and automated processes in sample distribution systems. A choice of colours enables colour-coding to facilitate laboratory logistics. False Bottom Tubes Sarstedt offers false bottom tubes in a range of diameters and volumes tailored to laboratory automation requirements. Caps Screw caps and stoppers in a variety of diameters are available to recap primary tubes or provide evaporation protection for backup samples. Please order our separate brochures and flyers for further information. 35

36 V-Monovette V-Monovette The vacuum blood collection system for transfusion medicine The V-Monovette vacuum blood collection system is specially designed for use in transfusion medicine. The V-Monovette exclusively serves to collect blood directly from the blood bag. V-Monovette The V-Monovette is available in 75 x 13 mm, 100 x 13 mm, and 100 x 15 mm options. A range of preparations and a choice of colour codes or labels enable compliance with the various requirements in transfusion medicine. Fill line at the tube end for volume control during collection 36

37 Extract from Range of Transfusion Medicine Products The following instruments are part of our extensive product range for transfusion medicine. TOPSWING The new TOPSWING blood weighing and mixing device is perfect for mobile and stationary donation. The innovative two-dimensional mixing mode ensures proper mixing of the anticoagulant and blood. Mobile donor bed The mobile donor bed is quickly set up and easily collapsed. It saves storage space and is convenient to carry. Tube Sealer MS 770 The Tube Sealer MS 770 is a high-frequency sealer for mobile use. The integral rechargeable battery performs at least 1,600 seals with a single charge. Tube Stripper AST-2S The Tube Stripper AST-2S has an integral rechargeable battery for automatic and non-tiring stripping of blood bag tubing. Please order our separate brochures and flyers for further information. 37

38 Service & Technical Support Assistance directly on Site at your Facility Competent service & technical support

39 Competent service & technical support You can rely on our skilled customer support either by phone or directly on site at your facility. Personal training and informative tools are available on request. Our service your benefit Our qualified product specialists are available to answer all your questions and support you anywhere, any time. Group or individual training is available to ensure products are used correctly and that users understand relevant safety and operational features. For us, SERVICE and COOPERATION also includes direct support to all your staff routinely involved with our products or assigned to be involved in the future. Thanks to our INTERNATIONAL LOGISTICS NETWORK, we have ready product availability in almost all regions worldwide ensuring maximum flexibility. Following group or personal TRAINING, using our safety products will soon become a familiar routine in your internal workflow. Our extensive network of skilled product specialists will be available to support you whenever needed.

40 If you have any questions: We will gladly assist you! 563d This document may contain information on products that may not be available in particular countries Technical modifications reserved SARSTEDT AG & Co. P.O. Box D Nümbrecht Phone Fax

PRODUCT CATALOGUE RESULTS OF THE SCIENTIFIC PROCESS

PRODUCT CATALOGUE RESULTS OF THE SCIENTIFIC PROCESS PRODUCT CATALOGUE RESULTS OF THE SCIENTIFIC PROCESS 2 disera RESULTS OF THE SCIENTIFIC PROCESS INDEX About Us 4 Production and Quality Certificates 5 VACUSERA Blood Collection Systems 6 VACUSERA Blood

More information

KABEVETTE. Aspiration and Vacuum in one System! The blood collection by KABE LABORTECHNIK KABEVETTE G KABEVETTE V. Aspiration

KABEVETTE. Aspiration and Vacuum in one System! The blood collection by KABE LABORTECHNIK KABEVETTE G KABEVETTE V. Aspiration KABEVETTE Aspiration Vacuum Aspiration and Vacuum in one System! The blood collection by KABE LABORTECHNIK KABEVETTE G KABEVETTE V Twice as good: Aspiration- and Vacuum principle can be combined in one

More information

Screw Cap Micro Tubes

Screw Cap Micro Tubes Screw Cap Micro Tubes For transport, storage and sample preparation Reliable quality and versatility Sicherheit Uncompromising... quality and purity Sicherheit... Over 30 years ago, Sarstedt introduced

More information

Transport and Mailing Systems

Transport and Mailing Systems Transport and Mailing Systems For transportation of diagnostic samples and blood products The complete product range for mailing and transport requirements Safe and compliant with transportation guidelines

More information

Central Line Blood Draw

Central Line Blood Draw Central Line Blood Draw Welcome to the Central Line dressing blood draw refresher. Please use the navigation below to advance to the next page. The Central Line blood draw module is also available as a

More information

The Golden Rule of Specimen Collection: The Patient Test Result is Only as Good as the Sample We Get

The Golden Rule of Specimen Collection: The Patient Test Result is Only as Good as the Sample We Get The Golden Rule of Specimen Collection: The Patient Test Result is Only as Good as the Sample We Get Jan Frerichs, MLS (ASCP) The University of Iowa Janice-frerichs@uiowa.edu Importance of Phlebotomist

More information

Collection Guidelines for Routine & Special Coagulation Testing

Collection Guidelines for Routine & Special Coagulation Testing Revised May 2010 Collection Guidelines for Routine & Special Coagulation Testing Best samples come from peripheral stick with evacuated tube system 19 to 22 gauge needle (smaller or bigger could cause

More information

Standard Operating Procedure (SOP) Work Package 8. Sample Collection and Storage

Standard Operating Procedure (SOP) Work Package 8. Sample Collection and Storage Standard Operating Procedure (SOP) Work Package 8 Sample Collection and Storage May 2008 SOP WP 8 - Sample collection Table of Contents 1 SAMPLE COLLECTION... 3 1.1 Sample collection -summary... 3 1.2

More information

MANITOBA PATIENT SERVICE CENTRE STANDARDS

MANITOBA PATIENT SERVICE CENTRE STANDARDS MANITOBA PATIENT SERVICE CENTRE STANDARDS February 2015 INTRODUCTION These Standards are derived from Z316.7-12 and are approved by the Council of the College of Physicians and Surgeons of Manitoba. These

More information

Blood Tubes and Lancets 1-800-962-9888

Blood Tubes and Lancets 1-800-962-9888 Blood Tubes and Lancets 1-800-962-9888 1-800-962-9888. Table of Contents BLOOD COLLECTION MONOJECT Blood Collection Products Safety Lancet... 4 Lancet... 4 Corvac Integrated Serum Separator Tubes Red/Grey

More information

Abstract... i. Committee Membership... iii. Foreword... vii. 1 Scope... 1. 2 Introduction... 1. 3 Standard Precautions... 1. 4 Definitions...

Abstract... i. Committee Membership... iii. Foreword... vii. 1 Scope... 1. 2 Introduction... 1. 3 Standard Precautions... 1. 4 Definitions... Vol. 27 No. 26 Replaces H3-A5 Vol. 23 No. 32 Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture; Approved Standard Sixth Edition This document provides procedures for the collection

More information

VACUETTE RNAgard Blood Tubes BioMaxi Blood RNA Purification Kit. For the collection, preservation and purification of RNA from whole blood

VACUETTE RNAgard Blood Tubes BioMaxi Blood RNA Purification Kit. For the collection, preservation and purification of RNA from whole blood RNAgard Blood System VACUETTE RNAgard Blood Tubes BioMaxi Blood RNA Purification Kit For the collection, preservation and purification of RNA from whole blood Instructions For Use Protocol blood collection,

More information

How to safely collect blood samples from persons suspected to be infected with highly infectious blood-borne pathogens (e.g.

How to safely collect blood samples from persons suspected to be infected with highly infectious blood-borne pathogens (e.g. How to safely collect blood samples from persons suspected to be infected with highly infectious blood-borne pathogens (e.g. Ebola) Step 1: Before entering patient room, assemble all equipment (1 st part)

More information

STEP-BY-STEP INSTRUCTIONS FOR INVESTIGATIONAL USE. Rapid HCV Antibody Test FOR ORAQUICK RAPID HCV ANTIBODY TEST

STEP-BY-STEP INSTRUCTIONS FOR INVESTIGATIONAL USE. Rapid HCV Antibody Test FOR ORAQUICK RAPID HCV ANTIBODY TEST Before performing testing, all operators MUST read and become familiar with Universal Precautions for Prevention of Transmission of Human Immunodeficiency Virus, Hepatitis B Virus, and other Blood-borne

More information

THE IMPORTANCE OF PRE-ANALYTICAL PHASE IN LABORATORY TESTING AND DIAGNOSIS. Tg Jiu, September, 2010

THE IMPORTANCE OF PRE-ANALYTICAL PHASE IN LABORATORY TESTING AND DIAGNOSIS. Tg Jiu, September, 2010 THE IMPORTANCE OF PRE-ANALYTICAL PHASE IN LABORATORY TESTING AND DIAGNOSIS Tg Jiu, September, 2010 Cristina Florescu Moraid MD MSc EurClinChem Country Manager Synevo Central Lab Romania-Medicover Holding

More information

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb Document: AND Lead 100 7 2013 Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb July, 2013 Edition 1 ANDalyze, Inc., 2012. All rights reserved. Printed in USA. Table of Contents

More information

ECMO AND LIFE SUPPORT SYSTEMS QUADROX PLS AND ROTAFLOW HARDWARE AND ACCESSORIES

ECMO AND LIFE SUPPORT SYSTEMS QUADROX PLS AND ROTAFLOW HARDWARE AND ACCESSORIES ECMO AND LIFE SUPPORT SYSTEMS QUADROX PLS AND ROTAFLOW HARDWARE AND ACCESSORIES The Gold Standard Cardiovascular QUADROX PLS and ROTAFLOW 3 QUADROX PLS AND ROTAFLOW INNOVATIVE PERFORMANCE AND RELIABILITY

More information

Helping to protect you from exposure to hazardous drugs

Helping to protect you from exposure to hazardous drugs Helping to protect you from exposure to hazardous drugs Closed system solution: Texium closed male luer and SmartSite needle-free valve products What you can t see can hurt you The risks are well documented

More information

Blood Plasma Sample Collection and Handling for Proteomics Analysis - A guide to obtain optimal plasma samples -

Blood Plasma Sample Collection and Handling for Proteomics Analysis - A guide to obtain optimal plasma samples - Blood Plasma Sample Collection and Handling for Proteomics Analysis - A guide to obtain optimal plasma samples - 1 Introduction Blood can be regarded as a complex liquid tissue that comprises cells and

More information

VENOUS BLOOD COLLECTION

VENOUS BLOOD COLLECTION Venous Blood Collection p. 1 of 5 Johns Hopkins Medical Laboratories Department of Pathology Core Lab Clinical Services Zd7: Word: JHH Venous Blood Collection Procedure Signature Date Signature Date Written

More information

UltraClean PCR Clean-Up Kit

UltraClean PCR Clean-Up Kit UltraClean PCR Clean-Up Kit Catalog No. Quantity 12500-50 50 Preps 12500-100 100 Preps 12500-250 250 Preps Instruction Manual Please recycle Version: 02212013 1 Table of Contents Introduction... 3 Protocol

More information

Plasmax Plasma Concentration System BIOLOGICS

Plasmax Plasma Concentration System BIOLOGICS Plasmax Plasma Concentration System BIOLOGICS Plasmax Plasma Concentration System Plasmax Plasma Concentrate System Contains Plasmax concentrator GPS III separator Provides 16ml of autologous output, 6ml

More information

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2 Uscn Life Science Inc. Wuhan Website: www.uscnk.com Phone: +86 27 84259552 Fax: +86 27 84259551 E-mail: uscnk@uscnk.com ELISA Kit for Human Prostaglandin E1(PG-E1) Instruction manual Cat. No.: E0904Hu

More information

Instructions for Use

Instructions for Use 1 Instructions for Use HUMULIN R U-500 KwikPen insulin human injection U-500 (500 units/ml, 3 ml pen) Important: Know your dose of HUMULIN R U-500 insulin. The Pen delivers your dose in insulin units.

More information

Laboratory Biosafty In Molecular Biology and its levels

Laboratory Biosafty In Molecular Biology and its levels Laboratory Biosafty In Molecular Biology and its levels Workshop 16-17 Oct..2012 Guidelines Does not mean optional Laboratory Biosafety The Laboratory Biosafety Manual is an important WHO publication

More information

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit Catalog No: E0479r 96 Tests Operating instructions www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH

More information

Thermo Scientific Capitol Vial Drugs of Abuse Products. The tools to create and maintain. a safe and drug free environment

Thermo Scientific Capitol Vial Drugs of Abuse Products. The tools to create and maintain. a safe and drug free environment Thermo Scientific Capitol Vial Drugs of Abuse Products The tools to create and maintain a safe and drug free environment Drugs of Abuse Specimen Collection We are a world leading manufacturer of Drugs

More information

RealLine HCV PCR Qualitative - Uni-Format

RealLine HCV PCR Qualitative - Uni-Format Instructions for use PCR KIT FOR EXTRACTION OF RNA AND REAL TIME PCR DETECTION KIT FOR HEPATITIS C VIRUS RNA Research Use Only Qualitative Uni Format VBD0798 48 tests valid from: December 2013 Rev11122013

More information

www.gbo.com/bioscience Tissue Culture 1 Cell/ Microplates 2 HTS- 3 Immunology/ HLA 4 Microbiology/ Bacteriology Purpose Beakers 5 Tubes/Multi-

www.gbo.com/bioscience Tissue Culture 1 Cell/ Microplates 2 HTS- 3 Immunology/ HLA 4 Microbiology/ Bacteriology Purpose Beakers 5 Tubes/Multi- 11 Cryo www.gbo.com/bioscience Technical Information 9 I 2 Leucosep TM 9 I 3 12 ml Leucosep TM Tubes 9 I 3 50 ml Leucosep TM Tubes 9 I 3 Instruction Manual Leucosep TM 9 I 4 OncoQuick 9 I 5 11 Cryo www.gbo.com/bioscience

More information

ClikSTAR - Important facts about your new insulin delivery device.

ClikSTAR - Important facts about your new insulin delivery device. ClikSTAR - Important facts about your new insulin delivery device. Instruction for Use ClikSTAR Insulin delivery device Before you start: Read these instructions and follow them completely each time you

More information

KwikPen Insulin delivery device

KwikPen Insulin delivery device USER MANUAL KwikPen Insulin delivery device PLEASE READ THESE INSTRUCTIONS BEFORE USE Lilly Introduction The KwikPen is designed for ease of use. It is a disposable pen containing 3 ml (300 units) of U-

More information

BD Diagnostics - Preanalytical Systems. Product Catalogue 2009/10

BD Diagnostics - Preanalytical Systems. Product Catalogue 2009/10 BD Diagnostics - Preanalytical Systems Product Catalogue 2009/10 BD, proud to sponsor An online resource to identify, evaluate and promote the application of best practices in all aspects of the preanalytical

More information

Medical Necessity and Advanced Beneficiary Notice (ABN) Policy and Form

Medical Necessity and Advanced Beneficiary Notice (ABN) Policy and Form Medical Necessity and Advanced Beneficiary Notice (ABN) Policy and Form Billings Clinic Laboratory believes all health-care providers should order only appropriate tests for the diagnosis and treatment

More information

Ward 29 guide to the safe preparation and administration of intravenous (IV) antibiotics at home

Ward 29 guide to the safe preparation and administration of intravenous (IV) antibiotics at home Ward 29 guide to the safe preparation and administration of intravenous (IV) antibiotics at home Contents Page Important contact numbers 1 General information on preparing and administering IV antibiotics

More information

I-140 Venipuncture for Blood Specimen Collection

I-140 Venipuncture for Blood Specimen Collection I-140 Venipuncture for Blood Specimen Collection Purpose Obtain a blood specimen by venipuncture for laboratory analysis using aseptic technique. Applies To Registered Nurses Licensed Practical/Vocational

More information

Syringe. Product Usage Information: Precautions:

Syringe. Product Usage Information: Precautions: Syringe Standard Draw Procedure In-Patient, Automated Retraction Non-Reusable. Prepare and give injection using aseptic technique according to institutional policy.. For injection into patients, continue

More information

NIH Clinical Center Patient Education Materials Giving a subcutaneous injection

NIH Clinical Center Patient Education Materials Giving a subcutaneous injection NIH Clinical Center Patient Education Materials What is a subcutaenous injection? A subcutaneous injection is given in the fatty layer of tissue just under the skin. A subcutaneous injection into the fatty

More information

Genomic DNA Extraction Kit INSTRUCTION MANUAL

Genomic DNA Extraction Kit INSTRUCTION MANUAL Genomic DNA Extraction Kit INSTRUCTION MANUAL Table of Contents Introduction 3 Kit Components 3 Storage Conditions 4 Recommended Equipment and Reagents 4 Introduction to the Protocol 4 General Overview

More information

EXERCISE 5: ERYTHROCYTES SEDIMENTATION RATE - ESR, SED RATE

EXERCISE 5: ERYTHROCYTES SEDIMENTATION RATE - ESR, SED RATE EXERCISE 5: ERYTHROCYTES SEDIMENTATION RATE - ESR, SED RATE Textbook: Skills: None 10 points Objectives: 1. State the principle of the Erythrocytes Sedimentation Rate - ESR. 2. List two factors which may

More information

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures. IgM ELISA For the quantitative determination of IgM in human serum and plasma For Research Use Only. Not For Use In Diagnostic Procedures. Please read carefully due to Critical Changes, e.g., Calibrator

More information

Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit

Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit Catalog No. CSB-E15852c (96T) This immunoassay kit allows for the in vitro quantitative determination of canine CK-MB concentrations in serum and plasma.

More information

Dimethylglyoxime Method Method 10220 0.1 to 6.0 mg/l Ni TNTplus 856

Dimethylglyoxime Method Method 10220 0.1 to 6.0 mg/l Ni TNTplus 856 Nickel DOC316.53.01065 Dimethylglyoxime Method Method 10220 0.1 to 6.0 mg/l Ni TNTplus 856 Scope and application: For water and wastewater. Test preparation Instrument-specific information Table 1 shows

More information

Fixed and Adjustable Spacing Electronic Pipettes

Fixed and Adjustable Spacing Electronic Pipettes viaflo Fixed and Adjustable Spacing Electronic Pipettes viaflo Electronic Pipettes All viaflo pipettes function as repeaters, mixers, serial dilutors, manual pipettes, handheld sample processors and more!

More information

Gravity Bag Cord Blood Collection Method Training Manual

Gravity Bag Cord Blood Collection Method Training Manual Gravity Bag Cord Blood Collection Method Training Manual CordBank Ltd. Training Manual Page 1 of 13 Table of Contents Chapter Page Introduction 3 Requirements for Collection of Cord Blood 3 Collector s

More information

ArtisanLink Staining System is an automated special stains slide

ArtisanLink Staining System is an automated special stains slide Technical Tips Tips on using the ArtisanLink Special Staining System Jamie Nowacek, BS, HT(ASCP) CM, QIHC, PMP Dako North America, Inc. Carpinteria, CA, USA ArtisanLink Staining System is an automated

More information

Guidelines for the Safe Transport of Infectious Substances and Diagnostic Specimens

Guidelines for the Safe Transport of Infectious Substances and Diagnostic Specimens Distr.: General Orig.: English Guidelines for the Safe Transport of Infectious Substances and Diagnostic Specimens WORLD HEALTH ORGANIZATION Division of Emerging and Other Communicable Diseases Surveillance

More information

Mouse Keyhole Limpet Hemocyanin antibody(igm) ELISA Kit

Mouse Keyhole Limpet Hemocyanin antibody(igm) ELISA Kit Mouse Keyhole Limpet Hemocyanin antibody(igm) ELISA Kit Catalog No. MBS702810 (96 tests) This immunoassay kit allows for the in vitro semi-quantitative determination of mouse KLH(IgM)antibody concentrations

More information

Hand Hygiene and Infection Control

Hand Hygiene and Infection Control C Hand Hygiene and Infection Control Sirius Business Services Ltd www.siriusbusinessservices.co.uk Tel 01305 769969 info@siriusbusinessservices.co.uk Whatever your First Aid, Fire Safety or Health & Safety

More information

A Self-Study Packet for The Johns Hopkins Hospital Point-of-Care Testing Program copyright 2011 Johns Hopkins Hospital All rights reserved

A Self-Study Packet for The Johns Hopkins Hospital Point-of-Care Testing Program copyright 2011 Johns Hopkins Hospital All rights reserved A Self-Study Packet for The Johns Hopkins Hospital Point-of-Care Testing Program copyright 2011 Johns Hopkins Hospital All rights reserved Overview and Objectives This module provides an introduction to

More information

Ion Selective Electrodes

Ion Selective Electrodes Ion Selective Electrodes OAKTON has a large selection of Ion Selective Electrodes () to suit a wide variety of applications. Each electrode has a typical response time of 20 to 30 seconds but will vary

More information

Safe medication. Disposable syringes

Safe medication. Disposable syringes Safe medication Disposable syringes Disposable syringes Safe medication Safety, reliability, and accuracy down to the smallest detail as with all other CODAN Products, this commitment also holds true for

More information

CataLoG No. weight o.d. i.d. GLaSSwaRe

CataLoG No. weight o.d. i.d. GLaSSwaRe Lead weights with Vikem Vinyl Coating Protect and Stabilize Expensive Glassware Stabilizes vessels in water baths and on benchtops Added insurance against tipping and possible chemical spills Closed ring

More information

Blood Collection and Processing SOP

Blood Collection and Processing SOP Brisbane Breast Bank Blood Collection and Processing SOP Breast Pathology Laboratory University of Queensland Centre for Clinical Research Blood Collection We collect 30ml of blood from patients who have

More information

www.gbo.com/bioscience Tissue Culture 1 Cell/ Microplates 2 HTS- 3 Immunology/ HLA 4 Microbiology/ Bacteriology Purpose Beakers 5 Tubes/Multi-

www.gbo.com/bioscience Tissue Culture 1 Cell/ Microplates 2 HTS- 3 Immunology/ HLA 4 Microbiology/ Bacteriology Purpose Beakers 5 Tubes/Multi- www.gbo.com/bioscience 11 Cryotechnics Technical Information 11 I 2 Cryo.s TM 11 I 3 Cryo.s TM 1 ml 11 I 3 Cryo.s TM 2 ml 11 I 3 Cryo.s TM 4 ml 11 I 4 Cryo.s TM 5 ml 11 I 4 Support Rack 11 I 5 Cryo Storage

More information

Sales News - Disposables

Sales News - Disposables March 2014 FlipTube A automation friendly microtube General information / background Most commonly used micro tubes cannot be automated, as they need to be opened and closed to complete the process. Users

More information

HAEMATOLOGY LABORATORY

HAEMATOLOGY LABORATORY HAEMATOLOGY LABORATORY Head of Unit : Dr Raudhawati Osman Phone : +603-26155281 Email : raudhaosman@yahoo.com 1. INTRODUCTION The Haematology Unit, Department of Pathology, HKL provides tertiary diagnostic

More information

Anti-Zona Pellucida Antibody Latex Agglutination Test

Anti-Zona Pellucida Antibody Latex Agglutination Test Instructions for use Anti-Zona Pellucida Antibody Latex Agglutination Test Cat. No.: BS-20-10 Size: 50 Determinations Storage: 2 C 8 C (36 F 46 F) Screening test for the determination of anti-zona pellucida

More information

Mouse IgM ELISA. Cat. No. KT-407 K-ASSAY. For the quantitative determination of IgM in mouse biological samples. For Research Use Only. 1 Rev.

Mouse IgM ELISA. Cat. No. KT-407 K-ASSAY. For the quantitative determination of IgM in mouse biological samples. For Research Use Only. 1 Rev. K-ASSAY Mouse IgM ELISA For the quantitative determination of IgM in mouse biological samples Cat. No. KT-407 For Research Use Only. 1 Rev. 072309 K-ASSAY PRODUCT INFORMATION Mouse IgM ELISA Cat. No. KT-407

More information

Washing. Sterilising. Filling. Closing. Inspecting. Labelling

Washing. Sterilising. Filling. Closing. Inspecting. Labelling Washing. Sterilising. Filling. Closing. Inspecting. Labelling Washing Page 4/5 Sterilising Page 6/7 Filling Page 8/9, 10/11 Closing Page 8/9, 10/11 Inspecting Page 12/13 Labelling Page 14/15 Syringe processing

More information

Mouse Creatine Kinase MB isoenzyme (CKMB) ELISA

Mouse Creatine Kinase MB isoenzyme (CKMB) ELISA KAMIYA BIOMEDICAL COMPANY Mouse Creatine Kinase MB isoenzyme (CKMB) ELISA For the quantitative determination of mouse CKMB in serum, plasma, cell culture fluid and other biological fluids Cat. No. KT-57681

More information

Section 10. Guidelines for the Safe Handling and Disposal of Needles and Sharps

Section 10. Guidelines for the Safe Handling and Disposal of Needles and Sharps Section 10 Guidelines for the Safe Handling and Disposal of Needles and Sharps On behalf of Infection Control Policy Review Group NHS Ayrshire and Arran Warning - this document is uncontrolled when printed

More information

9.Pediatric Procedures

9.Pediatric Procedures 9.Pediatric Procedures A. Introduction 1. Pediatric blood collection may be by skin puncture or venipuncture. 2. Skill in pediatric phlebotomy is gained by knowledge of special collection equipment, observation

More information

To maintain a port of entry to venous flow when all available peripheral ports have failed.

To maintain a port of entry to venous flow when all available peripheral ports have failed. I. Purpose: To maintain a port of entry to venous flow when all available peripheral ports have failed. II. General Comments: Since its development, these catheters have been used with increasing frequency

More information

Obtaining a venous blood sample

Obtaining a venous blood sample Obtaining a venous blood sample About this workforce competence This workforce competence covers the issue of obtaining a venous blood sample from a patient. The key tasks include correctly identifying

More information

Instructions for Use HUMALOG KwikPen insulin lispro injection (rdna origin)

Instructions for Use HUMALOG KwikPen insulin lispro injection (rdna origin) 1 Instructions for Use HUMALOG KwikPen insulin lispro injection (rdna origin) Read the Instructions for Use before you start taking HUMALOG and each time you get a refill. There may be new information.

More information

Biohazardous, Medical & Biological Waste Guidance Chart

Biohazardous, Medical & Biological Waste Guidance Chart CSULA Environmental Health and Safety Biohazardous, Medical & Biological Waste Guidance Chart The chart below provides information on how to handle most, if not all, of the items that frequently are collectively

More information

Pediatric Blood Draws HELEN MAXWELL

Pediatric Blood Draws HELEN MAXWELL Pediatric Blood Draws HELEN MAXWELL Special Considerations for Doing Pediatric Blood Draws Communication is a Must Positive Body Language..(Relaxed/Cheerful) Soft Voice Tone Special Considerations for

More information

Family Cord Blood Stem Cells Bank

Family Cord Blood Stem Cells Bank Family Cord Blood Stem Cells Bank Hope for life......evolves from life itself WHAT ARE STEM CELLS AND WHY ARE THEY PRESERVED? Cord blood stem cells are in the greatest percentage haematopoetic stem cells

More information

Learning to Self Inject Methotrexate at Home Developed by Andy Thompson MD FRCPC and Marie J Craig-Chambers B.Sc.Phm

Learning to Self Inject Methotrexate at Home Developed by Andy Thompson MD FRCPC and Marie J Craig-Chambers B.Sc.Phm Learning to Self Inject Methotrexate at Home Developed by Andy Thompson MD FRCPC and Marie J Craig-Chambers B.Sc.Phm Why might my Doctor ask me to inject Methotrexate? Methotrexate comes in two forms:

More information

Direct Antiglobulin Test (DAT)

Direct Antiglobulin Test (DAT) Exercise 8 Exercise 9 Direct Antiglobulin Test (DAT) Elution Study Task Aim Introduction To perform the DAT and elution procedure with correct interpretation of results. To perform with 100% accuracy the

More information

SPECIMEN COLLECTION 1

SPECIMEN COLLECTION 1 SPECIMEN COLLECTION 1 BLOOD 2 BLOOD SPECIMEN COLLECTION, PREPARATION AND HANDLING I. SPECIMEN COLLECTION A. Introduction As members of the health care team, phlebotomist must recognize that their primary

More information

ABO-Rh Blood Typing With Synthetic Blood

ABO-Rh Blood Typing With Synthetic Blood 70-0101 ABO-Rh Blood Typing With Synthetic Blood Teacher s Manual World-Class Support for Science & Math The ability to type blood is an invaluable tool in the fields of medicine and criminology. Using

More information

INTRODUCTION. Viral shedding is crucial for Gene Therapy Products Safety linked with shedding data

INTRODUCTION. Viral shedding is crucial for Gene Therapy Products Safety linked with shedding data INTRODUCTION Viral shedding is crucial for Gene Therapy Products Safety linked with shedding data For the patient For families and friends For the environment No treatment possible without good safety

More information

Go for the complete package.

Go for the complete package. Go for the complete package. Our services help you stand out in the market. Individual design options while leveraging the benefits of a device platform Flexible prototyping and devices for early studies

More information

Title: Fingerstick Glucose by Accu-Chek Inform

Title: Fingerstick Glucose by Accu-Chek Inform Title: Fingerstick Glucose by Accu-Chek Inform Target Audience: This module is available to aid in assessing competency for all clinical staff who perform fingerstick glucose testing. Contents Instructions...

More information

A Guide to Managing Your Biological Waste at the University at Albany

A Guide to Managing Your Biological Waste at the University at Albany A Guide to Managing Your Biological Waste at the University at Albany Section 1 - What you need to know: Definition: "Regulated Medical Waste (RMW) shall mean any of the following waste which is generated

More information

PROCEDURE NO. POC.514.01 LBH. Printed copies are for reference only. Please refer to the electronic copy for the latest version.

PROCEDURE NO. POC.514.01 LBH. Printed copies are for reference only. Please refer to the electronic copy for the latest version. Department Of Pathology POC.514.01- Blood Glucose Monitoring Accu-Chek Inform II Procedure-LBH Version# 1 Department PROCEDURE NO. PAGE NO. Point-of-Care Testing POC.514.01 LBH 1 OF 7 Printed copies are

More information

Policies & Procedures. ID Number: 1118

Policies & Procedures. ID Number: 1118 Policies & Procedures Title: INTRAVENOUS AND/OR PERIPHERAL SALINE LOCK INSERTION AND MAINTENANCE ID Number: 1118 Authorization [X] SHR Nursing Practice Committee Source: Nursing Date Revised: September

More information

Appendix H Managing Biohazardous Waste SOP

Appendix H Managing Biohazardous Waste SOP Biohazardous waste is managed under the State of Rhode Island s Regulated Medical Waste Regulations (Regulation DEM-OWM-MW-1-2009, amended July, 2010). http://www.dem.ri.gov/pubs/regs/regs/waste/medwaste10.pdf

More information

Human Free Testosterone(F-TESTO) ELISA Kit

Human Free Testosterone(F-TESTO) ELISA Kit Human Free Testosterone(F-TESTO) ELISA Kit Catalog Number. MBS700040 For the quantitative determination of human free testosterone(f-testo) concentrations in serum, plasma. This package insert must be

More information

Cytotoxic and Biotherapies Credentialing Programme Module 6

Cytotoxic and Biotherapies Credentialing Programme Module 6 Cytotoxic and Biotherapies Credentialing Programme Module 6 1. Safe Handling and Administration of Cytotoxic and Biotherapies 2. Waste and Spill Management At the completion of this module the RN will

More information

Sample Storage and Biobanking solutions for demanding long-term sample archiving requirements. Samplosophy 96 Data Matrix Sample Tube Rack System

Sample Storage and Biobanking solutions for demanding long-term sample archiving requirements. Samplosophy 96 Data Matrix Sample Tube Rack System Sample Storage and Biobanking solutions for demanding long-term sample archiving requirements Samplosophy 96 Data Matrix Sample Tube Rack System LVL CRYO 100/81 Data Matrix Sample Tube Rack System Capper

More information

How To Use A Blood Collection Collection System

How To Use A Blood Collection Collection System Transfusion Technology The state-of-the-art technology for the collection, processing and application of blood products SARSTEDT International Your partner in medicine and science worldwide Sicherheit

More information

Promoting safer use of injectable medicines

Promoting safer use of injectable medicines Promoting safer use of injectable medicines A template standard operating procedure for: prescribing, preparing and administering injectable medicines in clinical areas Introduction The use of injectable

More information

Appendix H IBC Managing Biohazardous Waste SOP

Appendix H IBC Managing Biohazardous Waste SOP Biohazardous waste is managed under the State of Rhode Island s Regulated Medical Waste Regulations (Regulation DEM-OWM-MW-1-2009, amended July, 2010). http://www.dem.ri.gov/pubs/regs/regs/waste/medwaste10.pdf

More information

MILESTONE CLEAN CHEMISTRY LINE DUOPUR TRACECLEAN ULTRA-TRACE INSERTS. A Breakthrough in Reduction and Control of the Analytical Blank MILESTONE

MILESTONE CLEAN CHEMISTRY LINE DUOPUR TRACECLEAN ULTRA-TRACE INSERTS. A Breakthrough in Reduction and Control of the Analytical Blank MILESTONE MILESTONE CLEAN CHEMISTRY LINE A Breakthrough in Reduction and Control of the Analytical Blank DUOPUR TRACECLEAN ULTRA-TRACE INSERTS MILESTONE MILESTONE CLEAN CHEMISTRY LINE An innovative and complete

More information

MEDICAL WASTE MANAGEMENT

MEDICAL WASTE MANAGEMENT MEDICAL WASTE MANAGEMENT Biological Safety INTRODUCTION PURPOSE Regulated medical waste is a designation for wastes that may contain pathogenic microorganisms which was previously termed infectious waste.

More information

(800) 786-7235 Cryo-Cell.com

(800) 786-7235 Cryo-Cell.com HEALTHCARE PROVIDER Instructions Keep these instructions in the kit [ When handling blood products, use personal protective measures, maintain aseptic techniques and adequate room for collection processes.

More information

INSTITUTIONAL POLICY AND PROCEDURE (IPP)

INSTITUTIONAL POLICY AND PROCEDURE (IPP) HOSPITAL NAME INSTITUTIONAL POLICY AND PROCEDURE (IPP) Department: Manual: Section: TITLE/DESCRIPTION POLICY NUMBER HAZARDOUS WASTE: HANDLING AND DISPOSAL EFFECTIVE DATE REVIEW DUE REPLACES NUMBER NO.

More information

EXERCISE 3: SKIN PUNCTURE ON INFANTS

EXERCISE 3: SKIN PUNCTURE ON INFANTS EXERCISE 3: SKIN PUNCTURE ON INFANTS Textbook: Skills: Chapter 12 Pediatric Procedures Dry Lab Objectives: 1. State the composition of skin puncture blood 2. List five (5) tests that cannot be preformed

More information

Policy and Procedure Flushing and / or Blood withdrawal Aspiration Procedure For PICC Line and Midline Catheters

Policy and Procedure Flushing and / or Blood withdrawal Aspiration Procedure For PICC Line and Midline Catheters Policy and Procedure Flushing and / or Blood withdrawal Aspiration Procedure For PICC Line and Midline Catheters Purpose: Blood Withdrawal: To obtain blood samples for laboratory evaluation, eliminating

More information

MISSISSIPPI BOARD OF NURSING IV THERAPY COURSE FOR THE EXPANDED ROLE LICENSED PRACTICAL NURSE COURSE OUTLINE

MISSISSIPPI BOARD OF NURSING IV THERAPY COURSE FOR THE EXPANDED ROLE LICENSED PRACTICAL NURSE COURSE OUTLINE THEORY MINIMUM 40 HOURS COURSE OUTLINE UNIT TOPIC HOURS* I LEGAL ASPECTS AND PRACTICE OF IV THERAPY 1 II REVIEW OF ANATOMY AND PHYSIOLOGY 6 III FLUID AND ELECTROLYTE BALANCE 10 IV EQUIPMENT AND PROCEDURES

More information

AxyPrep TM Mag PCR Clean-up Protocol

AxyPrep TM Mag PCR Clean-up Protocol AxyPrep TM Mag PCR Clean-up Protocol Intro The AxyPrep Mag PCR Clean-up kit utilizes a unique paramagnetic bead technology for rapid, high-throughput purification of PCR amplicons. Using this kit, PCR

More information

Advanced Phlebotomy: An on-line Course for Working Phlebotomists. MORE QUESTIONS? Send questions to phlebotomy@losrios.edu

Advanced Phlebotomy: An on-line Course for Working Phlebotomists. MORE QUESTIONS? Send questions to phlebotomy@losrios.edu Advanced Phlebotomy: An on-line Course for Working Phlebotomists MORE QUESTIONS? Send questions to phlebotomy@losrios.edu This course is designed for whom? This course is specifically designed for experienced

More information

INSTRUCTIONS FOR USE. Read this information before you start. Important things to know about your SmartJect autoinjector. Important things to remember

INSTRUCTIONS FOR USE. Read this information before you start. Important things to know about your SmartJect autoinjector. Important things to remember INSTRUCTIONS FOR USE SIMPONI (SIM-po-nee) (golimumab) SmartJect autoinjector If your doctor decides that you or a caregiver may be able to give your injections of SIMPONI at home, you should receive training

More information

QuantiFERON TB Gold In Tube Method (QGIT Test) Manufacturer: Cellestis Inc. (USA) a QIAGEN Company

QuantiFERON TB Gold In Tube Method (QGIT Test) Manufacturer: Cellestis Inc. (USA) a QIAGEN Company QuantiFERON TB Gold In Tube Method (QGIT Test) Manufacturer: Cellestis Inc. (USA) a QIAGEN Company P1078 TB APPRISE TB Ante vs. Postpartum Prevention with INH in HIV Seropositive mothers and their Exposed

More information

Archived. Gloves should be changed frequently during the analysis.

Archived. Gloves should be changed frequently during the analysis. Introduction Gloves and laboratory coats Small tools Specific clean-up and housekeeping procedures are used to help protect evidence samples from conditions and agents that might serve to destroy, deteriorate,

More information

DIRECTED UMBILICAL CORD BLOOD AND TISSUE COLLECTION IN THEATRE (CELLCARE)

DIRECTED UMBILICAL CORD BLOOD AND TISSUE COLLECTION IN THEATRE (CELLCARE) WOMEN AND NEWBORN HEALTH SERVICE King Edward Memorial Hospital CLINICAL GUIDELINES PERIOPERATIVE GUIDELINES DIRECTED CORD CELL COLLECTION IN THEATRE DIRECTED UMBILICAL CORD BLOOD AND TISSUE COLLECTION

More information

Flushing and Dressing a Peripherally Inserted Central Catheter (PICC Line): a Guide for Nurses

Flushing and Dressing a Peripherally Inserted Central Catheter (PICC Line): a Guide for Nurses Flushing and Dressing a Peripherally Inserted Central Catheter (PICC Line): a Guide for Nurses Information for Nurses Introduction This information is for community nursing staffs who have been asked to

More information

Dot Blot Analysis. Teacher s Guidebook. (Cat. # BE 502) think proteins! think G-Biosciences www.gbiosciences.com

Dot Blot Analysis. Teacher s Guidebook. (Cat. # BE 502) think proteins! think G-Biosciences www.gbiosciences.com PR110 G-Biosciences 1-800-628-7730 1-314-991-6034 technical@gbiosciences.com A Geno Technology, Inc. (USA) brand name Dot Blot Analysis Teacher s Guidebook (Cat. # BE 502) think proteins! think G-Biosciences

More information