Clean disposal. Geberit drainage systems, waste fittings and traps. Geberit Sales Ltd Geberit House Academy Drive Warwick Warwickshire CV34 6QZ
|
|
- Shannon Mathews
- 8 years ago
- Views:
Transcription
1 Geberit Sales Ltd Geberit House Academy Drive Warwick Warwickshire CV34 6QZ T F Eire +44 (0) Literature Clean disposal. Geberit drainage systems, waste fittings and traps. by Geberit Sales Ltd
2 Water, simply connected. Play safe. Almost no other company can understand plumbing technology as well as Geberit. Our expertise covers the entire pathway taken by water on its way through a building. Geberit systems can be relied upon one hundred per cent from the water supply connection, via the risers and distribution pipes to the usage points, through to drainage from the roof and from the rest of the building into the public sewerage system. So if you place your faith in Geberit drainage systems, waste fittings and traps, you can offer your customers a solution that represents the very latest technology in terms of hydraulics, acoustic insulation, fire protection, reliability ease of installation and environmental friendliness. 3
3 Everything for drainage. Drainage Geberit Silent-db Geberit HDPE Geberit Sovent Roof drainage Geberit Pluvia Safety and comfort Fire protection and sound insulation Inlets and drains in the bathroom Bathtub inlets and drains Shower drains Floor drains and shower channels Shower frame with wall drain Floor drain Washbasin traps Certificates for Geberit HDPE applications Partners British Board of Agrément Institute of Plumbing Istituto Italiano dei Plastici WPC/World Plumbing Council SKZ (Süddeutsches Kunst stoffzentrum) KOMO certificate EN 1519 DIN DIN EN ISO Standard 9001 ISO Standard
4 Complete Geberit technology. With everything working in harmony. Drainage means more than just draining away water at least as far as Geberit is concerned. Geberit invests a good deal of know-how in the development of innovative products to ensure that drainage technology keeps pace with reality on the building site as well as continuing to meet high standards in terms of sound insulation and fire protection. Even things that have proven themselves a million times can be made better. Geberit is market leader in the field of plumbing and drainage technology in Europe. Year after year Geberit invests more than almost all other companies in this industry in the continuous optimisation of existing systems and in the development of new technologies and products. High level of expertise in fire protection and sound insulation In addition to laboratories for sanitary technology and material development, Geberit also operates a building technology and acoustics laboratory that is unique throughout the world. Here, not only individual components but entire drainage systems are tested for their hydraulic, acoustic and static characterstics. Thus for example, the sound transmission of discharge stacks can be tested and optimised over several floors under realistic conditions. Geberit works closely with external testing bodies in the field of fire protection. Both prototypes as well as production parts are tested under realistic conditions. This development work takes full account of the varying national fire protection standards of different countries. System solutions with high flexibility For Geberit, waste fittings and traps are the principal part of the waste water installation and, together with the Geberit piping systems, form a homogenous unit with simple interfaces. Geberit waste fittings and traps also create perfect connections to the sanitary appliances. No matter whether it is a question of high end bathroom design, whether applications for less abled people are called for or simply whether construction should be as spacesaving as possible Geberit offers the fitting solution. Good things are those that professionals enjoy installing The success of a product or technology stands and falls with its practical suitability on the building site and with its price vs. value. For this reason, all new or further development work takes account of all feedback and suggestions from plumbers from all over the world. With this in mind, Geberit also invests its know-how in its products and systems. Compliance with sound insulation and fire protection standards Safe connection technology, waste fittings and traps Fitting solutions for almost every area of use 6 7
5 Geberit Silent-db20. Waste water on a quiet foundation. Flexible and versatile: fittings for almost every conceivable installation situation. With the Geberit Silent-db20 drainage system the sound insulation is already installed. As a result it impressively fulfils existing sound insulation requirements. Pipes, fittings, connections, fastenings and insulation can be processed economically and offer everything needed for a practical drainage system. 1 Triple protection against sound The mineral-filled plastic PE-S2 is used for the manufacture of Geberit Silent-db20. It increases the density of the pipes and fittings. This reduces natural vibrations and effectively insulates the sound. Additional sound insulation ribs in the impact zones help reduce noise development. System pipe brackets for wall fastening decouple the system acoustically from the wall or ceiling and prevent sound transmission. Always the right dimension The branch dimensions in the typical discharge stack are hydraulically optimised. This enables a higher load on the discharge stack and in part permits the use of smaller discharge stack dimensions. Pipes and fittings are available from DN 56 to DN 150. Two safe connection types Two different connection types are available depending on the application. Screwed clamping connectors can be loosened at any time and thus enable correction of the installation. Full tensile strength is achieved easily and safely using the electrofusion coupling, thus offering additional safety when laying in concrete. Separation and installation does not involve dangerous flexing. Processing residue can be re-used as fitting pieces are disposed of without problems. Pipe ventilation BON-AIR For installations which do not permit conventional ventilation for space reasons, Geberit also offers the BON-AIR air admittance valve for dimensions up to DN Hydraulically optimised fittings with sound insulation ribs. 2 High-tensile connection with electrofusion sleeve coupling. 3 High material strength for reduced noise: PE-S2 mineral-filled plastic. Outstanding sound insulation Diverse system with numerous dimensions and fittings Hydraulically optimised fittings Precise and safe processing without flying sparks Little cutting waste and environmentally friendly disposal 8 9
6 Geberit HDPE drainage pipes. Pipes for professionals. Fittings and connections for many different areas of use. Enormous temperature fluctuations, aggressive waste water, pressure, offsetting and chemical influences: Wherever drainage requires high resistance capability, you are on the right side with Geberit HDPE drainage pipes. Geberit HDPE resists temperatures, pressure and aggressive media The Geberit HDPE drainage system is produced from the robust pipe material high density polyethylene (PE-HD). It is suitable for a number of uses such as in industry, commerce or laboratories, for underground installation, in concrete or bridge buildings as well as for house drainage. Hot water up to 80 C, for short periods and without mechanical load even up to 100 C, does not attack the material. It is resistant to roughly 95 percent of all common household alkalis, acids and chemicals. The pipes and fittings can also withstand shock, lowering, knocks or pressure up to 1.5 bar without breakage or lasting deforma tion. The plastic used is environmentally friendly and completely recyclable. No toxic emissions whatsoever result during its processing or in the event of fire. Geberit HDPE long-term stable connections Geberit HDPE pipes are available in the dimensions of DN 30 to DN 300 with a broad range of fittings. Depending on the use, the pipes and fittings can be connected by butt welding, electrofusion, screw connections or flanges. Fits in with Geberit system technology Geberit HDPE pipes and fittings are incorporated seamlessly into the Geberit system with its fire protection, roof drainage and industry systems and can be combined with these without any problems. Wide range of dimensions High resistance to temperatures and chemicals Flexible and impact-resistant Various jointing options 6 Environmentally friendly plastic Eccentric reducer 2 Access cap for cleaning 3 Electrofusion coupling 4 Y-branch swept-entry 5 Expansion coupling 6 Butt weld 7 Flange connection 10 11
7 Geberit Sovent. Economic and perfected drainage of high-rise buildings. The Geberit Sovent fittings for optimised flow enable inexpensive design of discharge stacks in high-rise buildings. They increase the pipe capacity many times and render the installation of a parallel ventilation pipe unnecessary. 1 Tricky challenge for hydraulic technicians In conventional discharge stacks very special flow laws apply above a certain length. Quickly changing pressure situations can result in the horizontal pipes connected to the discharge stack being sucked empty by high negative pressure or being blown empty by overpressure. Both are extremely undesirable. To avoid this situation, many high-rise buildings have very generously dimensioned discharge stacks and a parallel ventilation pipe which is connected to the discharge stack at regular intervals. Robust and completely systemcompatible Geberit Sovent is available in two different sizes for discharge stacks with a diameter of 110 or 160 mm. The fitting is produced from the resistant plastic HDPE and can be welded together with Geberit HDPE or Geberit Silent-db20 drainage pipes making it absolutely leakproof and pressure resistant. 2 Geberit know-how With the Sovent fitting, Geberit has developed an inexpensive and technically perfected alternative to conventional drainage systems in high-rise buildings. Geberit Sovent prevents a hydraulic seal in the discharge stack, thus increasing the flow capacity of the discharge stack. At the same time, Sovent ensures air circulation between branch discharge pipe and discharge stack. This makes a parallel ventilation pipe unnecessary. In addition, a partition prevents the penetration of foam or spray water into the branch discharge pipe. 1 Installation examples 2 Comparison of conventional and Sovent stacks 3 Numerous connection options 3 Economic alternative to conventional discharge stacks Improved flow characteristics High capacity Compatible with Geberit HDPE and Geberit Silent-db
8 Geberit Pluvia. Extract rain instead of allowing it to drain. Double the discharge amount at half the pipe diameter: Through the Pluvia Siphonic roof drainage system, Geberit has, for decades, been setting standards in roof drainage and gives architects and planners greater freedom in the construction of halls and roofs. 1 Economic roof drainage thanks to negative pressure The Geberit Pluvia roof outlets ensure that the relatively smaller dimensioned collector pipes and discharge stacks fill up quickly whenever it rains. This creates a closed, quick flowing water column in the pipelines and thus negative pressure. As a result, there is no need to have a slope in the horizontal collector pipe. The rain water is extracted thanks to the negative pressure. The increased flow speed also improves the selfcleaning of the pipes and thus reduces the risk of clogging. Planning with Geberit ProPlanner and Pluvia module The Geberit ProPlanner software is suitable for planning a roof drainage system with Geberit Pluvia. Taking account of currently applicable standards, the software calculates the entire system, including fire protection sleeves and sound insulation. It prepares quotation and materials lists as well as a hydraulics list. The isometric graph can be exported to a CAD program and further processed there. 2 Siphonic roof drainage system for considerably higher drainage capacity Various dimensions for drainage capacity of 1 to 100 litres/second Fewer discharge stacks and underground pipes, fewer channel connections More freedom of design, less planning workload Geberit Pluvia gives architects more freedom of design compared to conventional roof drainage as a lower number of roof outlets as well as of discharge stacks and underground pipes is required. Material costs and ground work are also reduced. 3 More freedom of design, less planning workload 4 Professional planning with Geberit ProPlanner Fewer pipes, fewer roof outlets: the Geberit Pluvia negative pressure system. 1 Partial filling 2 Complete filling 3 Conventional 4 Negative pressure drainage with Geberit Pluvia 14 15
9 Geberit Pluvia. A proven and versatile system. Cold and warm roof constructions, inverted roofs or green roofs: Geberit Pluvia can be used in many construction situations. The three system components Pluvia roof outlet, Geberit HDPE piping system and Pluvia fastening system create clear installation advantages compared to conventional roof drainage systems. React flexibly to all construction situations: Geberit Pluvia roof outlet. Good connections everywhere and at all times Geberit Pluvia rainwater outlets are suitable for installation in a wide variety of rood constructions. They can be welded to almost all plastic or bituminous roof foils. The connection to the Geberit HDPE drainage pipes is via a fixed welding connection or the Geberit Pluvia connection pipe that enables even more flexible and easy installation. Economic lightweights The pipe joints for the roof drainage are designed with Geberit HDPE drainage pipes. The individual pipe sections are welded together so that the tightness required for the creation of negative pressure is guaranteed. Geberit HDPE pipes are quick and easy to process and their low weight facilitates installation at greater heights. Individual pipe sections can be pre-assembled in the workshop. Flexible fastening The flexible Geberit fastening system makes installation of horizontal pipe sections particularly easy and safe. A square steel profile running parallel to the drainage pipe makes it possible to bridge large distances with just a few fastenings on the wall or ceiling. The fastening system absorbs thermally related shear forces and tensile loads via anchor brackets. Safety in all cases To be equipped for frequently occurring heavy rain and resulting static loads on the roof construction, emergency drainage must be provided for. This must direct the water to an area that can be flooded without causing damage. Warm roof lightweight construction Cold roof lightweight construction Extensive green Intensive green Suitable for all roof constructions Low system weight thanks to small pipe diameters Completely welded Warm roof solid construction, graveled Cold roof solid construction Inverted/wet roof, graveled Gutter installation, soldered or flanged Flexible fastening 16 17
10 Geberit fire protection and sound insulation. Functionality with safety installed. High level of safety and comfort through integral systems Versatile use of Geberit RS90 Plus fire protection sleeve With fire protection and sound insulation products that have proven themselves many times over, Geberit offers solutions backed by a great deal of know-how and experience. They ensure that you and your customers can sleep in peace. 1 Complete system with system pipe brackets and insulation materials Safety in the system Fire protection and sound insulation of a drainage system are always only as good as their weakest component. If elements from various manufacturers are combined, there is a risk of compromise at the interfaces. Compliance with applicable standards and regulations is likewise more difficult. Geberit therefore offers you complete systems with warranty and the evidence required for your project. This enables you to offer your customers a demonstrably high level of safety prior to the spread of a fire through the drainage pipes. Geberit s sound insulation expertise also enables you to ensure that drainage noise in private homes, public buildings, hotels and business premises is reduced to a minimum. Sound insulation from a single source In addition to the optimised sound insulation system, Geberit Silent-db20, intelligent fastening and insulation techniques ensure that sound development from the waste water remains low. The system pipe bracket for Geberit Silent-db20, the environmentally friendly sound insulation mat Geberit Isol, the insulation hose and the self-adhesive insulating tape complete the sound insula tion system. 2 3 Reliable protection against the spreading of fire Holes in walls and ceilings as well as installation ducts can promote the spread of fires in a building if they are not closed correctly and in accordance with standards. The Geberit RS90 Plus fire protection sleeve closes the pipe opening in the event of fire and prevents the spreading of smoke, fire and heat to other rooms or parts of the building. The Geberit RS90 Plus can be used with all Geberit drainage systems. 4 1 Installation flush with the ceiling 2 Diagonal in-ceiling installation 3 In-wall installation 4 Diagonal in-wall installation 18 19
11 Geberit bathtub inlets and drains. Function in top form. Geberit inlets, drains and overflows for bathtubs convince through well-thought-out details for greater safety, comfort and functionality, and impress with stylish design. Geberit bathtub drain Geberit bathtub drains intelligent details Easy installation as well as safe, tensionfree installation are ensured through the flexible bellows seal on the overflow. Seals on both sides of the drain and overflow protect bathtubs of all materials against corrosion damage. Flexible bellows seal for tensionfree installation Geberit bathtub drain with inlet function Flow engineering The traps shaped for optimised flow ensure high drainage capacity and optimum self-cleaning. Thanks to a low construction height they enable comfortable entry into the bath. All-round seals on both sides on the overflow Complete range Geberit bathtub drains are available in various dimensions and in the typical sanitary tapware colours: gloss chrome or white - a suitable solution for all bathtub types and all customer wishes. Intelligent details for easier installation and safety Shaped for optimised flow Geberit PushControl bathtub drain flat construction height comfortable to lean against and outlet Complete range for all areas of use Certified as per BS EN
12 Geberit shower drains. Low height with high performance. Geberit shower drains offer high practical value thanks to the low construction height. They are also extremely easy to maintain and convince through outstanding drainage capacities. Geberit shower drain d90 Construction height and ergonomics The trap casing of the Geberit shower drains has a low construction height which ensures flat placement of the tray and thus comfortable entry for your customers. Maintenance and cleaning made easy: removable dip tube Geberit shower drain d50/60 Safety and easy cleaning Seals on both sides protect shower trays from various materials against water damage. The trap casing inserts can be removed comfortably, thus enabling easy cleaning of the drainage pipe. Variants Geberit shower drains are available in all common dimensions and in the typical sanitary tapware colours: bright chromeplated, white alpine, matt chrome-plated and gold-plated. Low construction height enables comfortable entry Low construction height for comfortable entry Optimum protection of the tray Good accessibility enables easy cleaning The shower drain for every shower tray 22 23
13 Geberit shower channel. Wetroom shower design of the highest level. The Geberit shower channel convinces right down the line: timeless elegance, high-quality materials and technical refinement for demanding customers. 1 Mounting feet fastening, comfortable setting and sound insulation combined The Geberit shower channel stands on four feet fixed to the floor which are also used for height adjustment. Maintenance and cleaning made easy: removable dip tube The cubic design of the sound insulation case also enables easy and closed laying of the insulation. 2 The subsequent removal of the threaded pins interrupts the sound bridge between the useful layer and building structure and thus ensures compliance with the highest sound insulation standards. 1 No matter whether stainless steel design directly on the wall or individually tiled in the centre of the room, the Geberit shower channel embodies timeless design. Versions The Geberit shower channel is available in the room and wall installation versions and in five lengths between 70 and 120 cm. The design cover is available in the versions brushed stainless steel or tile bearing; this enables individual adaptation to each bathroom design. Foot construction for optimum sound levels Various versions and setting options Easy installation Modern design Sound insulation certified for increased requirements 24 25
14 Geberit shower frame with wall drain. Wetrooms, redefined. The innovative Geberit shower frame for wetroom showers transfers the drain unit from the floor to the wall. The result: simplified planning and installation with an attractive design. 1 Geberit shower element consistent system technology Geberit shower frame is an integral component of the Geberit Duofix installation system. Drainage pipes are guided in the prewall sound insulation and fire protection subjects are solved within the framework of the Geberit system technology. 1 2 Flexibility Geberit frames offer enormous flexibility in bathroom design. This philosophy is consistently continued with the shower frame. 2 Safe sealing Geberit shower frame is equipped ex-factory with flexible connections for composite sealing, thus ensuring simple, reliable and durable sealing. 3 Design cover The cover is available in four different versions the fitting design for every bathroom. The stainless steel version is also offered as a vandal-resistant option. 3 4 Shower drainage integrated into the prewall 4 Simple planning and installation Perfectly coordinated with the construction process Modern design 1 4 The design cover for the Geberit shower element is available in four versions: stainless steel, tile bearing, chromeplated and white. 1 Adjust the drain unit. 2 Form the slope in the screed. 3 Attach the sealing collar. 4 Set the compensation frame. Sound insulation certified for increased requirements 26 27
15 Geberit floor drain. Wetroom, comfort and function. The proven Geberit floor drain offers excellent value for money and high flexibility during installation a well-thought-out solution for wetrooms. Design grating in various styles Easy installation Special lugs attached to the trap casing ensure reliable positioning. The drain body can also be set flexibly to different floor structures in terms of insulation, screed and tile thickness. Low minimum construction height Easy cleaning The hair trap integrated invisibly beneath the grating can be removed; it enables easy cleaning and prevents clogging of the drain and of the subsequent pipe. One base unit, six design options Six different design gratings in various styles are available for the Geberit floor drain for showers. The standard grating is also available in a screw-locking variant. Flexible setting For use in wetrooms Intelligent details for easier installation Design grating in solid stainless steel 28 29
16 Geberit washbasin traps. Channel water away safely and quickly. Geberit offers a comprehensive range of attractive washbasin traps: optimised flow right down to the final detail, absolute corrosion resistance and proven a million times over. The Geberit design trap: ultimate solution and easy installation thanks to high-quality materials. Flow engineering Geberit washbasin traps are shaped for optimised flow thanks to computer-animated simulation technology. This guarantees rapid outflow of the waste water and simultaneously achieves a self-cleaning effect. Geberit direct trap Plastic high quality, durable, easy to install Geberit traps are produced from corrosionresistant plastic. This gives them a long service life and enables easier installation. Complete range Geberit direct traps for washbasins the universal design solution, fits every washbasin. Direct traps are available in gloss chrome. Optimised flow High level of corrosion resistance Easy installation Complete range Ultimate design for practically every washbasin 30 31
17 Know-How Installed. Innovative system technology for professional sanitary installations. Geberit masters the art of developing practical products. This is not without reason. On the one hand, we use our complete knowledge and experience for each new and further development. On the other hand, our engineers and product designers are often found on construction sites, with plumbers or consultants. Because this is where the decision is taken as to whether an idea is really practical. Con sequently, our products also contain the know-how of our market partners. Know-How Installed something we can all be proud of. Using Geberit systems means playing it safe. No uncertainties that can result when combining components from different manufacturers and no unnecessary material costs and installation workload. In addition, Geberit systems offer maximum reliability and economic viability, and have a minimum impact on the environment. 1 Geberit cisterns and mechanisms Exposed and concealed cisterns and clever flush control solutions all offer the perfection you have come to expect from Geberit, down to the finest detail. Together with the Geberit Monolith sanitary modules, the countless attractive Geberit flush plates and urinal flush controls, this creates efficient flush control solutions for WCs and urinals that fit into modern bathrooms. 2 Geberit installation systems No matter if it s a solid wall or drywall, prewall or inwall installation: With Geberit Duofix you will find the optimum solution for every sanitary application. At the same time, you have the certainty of using efficient and economic system technology in bathroom construction and renovation. 3 Geberit supply systems The Geberit Mapress and Geberit Mepla pressing systems together with an coordinated assortment of product materials, dimensions and fittings allow for the quick, easy, reliable and efficient installation of domestic and industrial supply systems. Naturally, the necessary pressing tools are part of the system. The robust Geberit pressing systems ensure quick and flexible connection. 4 Geberit drainage systems Drainage systems for building drainage, the acoustically optimised Geberit Silent-db20, the indestructible Geberit HDPE system and the use in industrial and laboratory drainage, and the Geberit Pluvia siphonic roof drainage system can be combined to form complete solutions for drainage. Geberit waste fittings and traps ensure hydraulically optimised and stylish connection to sanitary appliances. 5 Geberit taps and flushing systems for public facilities Only genuinely reliable sanitary technology products will satisfy the high and diverse requirements of semi-public and public sanitary facilities. Electronic and mechanical urinal and WC flush controls and quickresponse washroom taps ensure hygienic, economic operation and create a harmonious overall impression together with the Geberit urinal divisions
18 Sustainable. Plastic pipes perform well in the ecobalance. Further information is available at: /Silent-db20 /HDPE /Sovent Ecobalance Environmental impact of pipe systems in comparison, measured in eco-indicator points (EIP99) of the Dutch ecobalance method. 1,2 1,0 Optimum comfort and minimum environmental impact this is Geberit s answer to the challenges of today. As a leading manufacturer of sanitary technology, we make every effort to use natural resources carefully, thus making a contribution towards protecting the environment. With cast iron pipes, melting of the iron at temperatures of over 1000 C and the high transport weight of the pipes make a decisive contribution to the environmental impact. With plastic pipes, on the other hand, almost only the raw material is of significance. Production is very energy efficient and even disposal in modern combustion plants causes only a low environmental impact. This can be reduced even further through one hundred percent recycling. /Pluvia 0.8 0,6 0,4 0,2 0,0 Geberit Silent-db20 pipe Cast iron pipes This begins with the development of our products and extends to their manufacture and use through to responsible recycling. Geberit products are durable and reliable goods that make a significant contribution to protecting natural resources. Examples are the sound-optimized plastic pipes Geberit Silent-db20 and Geberit HDPE for building drainage. These pipes, developed and produced by Geberit, perform considerably better from an ecological perspective than traditional discharge pipes of cast iron. The advantages for you as customer are obvious: you benefit from a sound-optimised and durable drainage system that can be installed easily and quickly. And, at the same time, you create an added value for the environment. 34
Clean drains. Solutions for wetroom showers.
Clean drains. Solutions for wetroom showers. Fewer hurdles more sales. Wetroom showering is the latest trend and opens up new opportunities for bathroom designers, plumbers and installers. Geberit helps
More informationGeberit Pluvia siphonic roof drainage system. Stands up to every kind of rainfall
Geberit Pluvia siphonic roof drainage system. Stands up to every kind of rainfall Geberit Pluvia projects. Proven application. Westfield Shopping Centre, Stratford UK Guangdong Science Centre, China Hotel
More informationGeberit Pluvia Syphonic roof drainage system. Stands up to every kind of rainfall
Geberit Pluvia Syphonic roof drainage system Stands up to every kind of rainfall What is Pluvia? Geberit Pluvia is a roof drainage system based on an intelligent negative pressure suction system. In contrast
More informationSyphonic Roof Drainage
Syphonic Roof Drainage A D V A N C E D P L U M B I N G T E C H N O L O G Y Design Guide SYPHONICS Advanced Roof Drainage Technology Design, Manufacture and Installation TSB Call Centre, Cardiff. Millenium
More information3. Geberit Pluvia Roof Drainage Systems
3. Geberit Pluvia Roof Drainage Systems Assortment overview: Pluvia Outlets...52 3.1 Roof outlets... 53 3.1.1 Roof outlets up to 25 l/s...53 3.1.2 Roof outlets up to 100 l/s...55 3.2 Roof outlets for gutters...
More informationSyphonic Roof Drainage
Page 1 T E C H N O L O G Y 2:39 pm Syphonic Roof Drainage P L U M B I N G 23/5/03 A D V A N C E D Prod & Price Gd.for PDF Product Guide SYPHONICS Advanced Roof Drainage Technology Geberit Syphonics Geberit
More informationThis unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. The unit will start automatically. Please pay particular
More informationSchlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing
Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight
More informationDrainage and Grease Management for the Commercial Kitchen
Drainage and Grease Management for the Commercial Kitchen ACO. The future of drainage. The ACO system chain provides drainage solutions to meet the needs of tomorrow s food service facilities. Hostile
More informationSoil and waste for high-rise
1.2 Soil and waste systems for high-rise Because skyscrapers are designed evermore extreme, a single stack soil and waste system offers you the possibility to aim higher. Today, whether a consultant or
More informationShower and Floor Gullies Channel Drain and Tile Drain SECTION
Shower and Floor Gullies Channel Drain and Tile Drain SECTION 2 Shower and Floor Gullies, Channel Drain and Tile Drain 29 General Information Shower and Floor Gullies McAlpine has responded to market conditions
More informationACO ShowerDrain S-line Setting new standards for bathroom drainage
ACO ShowerDrain S-line Setting new standards for bathroom drainage ACO. The future of drainage. The ACO system chain provides the drainage solutions for tomorrow s environmental conditions. Increasingly
More information1. Description. 2. List of Accessories included A B C F G H
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin. The unit will start automatically. Please pay particular attention to the following: Possible danger to
More information1501-04-04-03-01:2009 HELLENIC CHNICAL SPECIFICATION. 32176 ежглеяис тгс йубеямгсеыс (теувос еутеяо) Sanitary ware, common 2009-12-23 ICS: 93.
32176 ежглеяис тгс йубеямгсеыс (теувос еутеяо) 2009-12-23 ICS 93160 1501-04-04-03-012009 H HELLENIC CHNICAL SPECIFICATION Sanitary ware common 10 313 111 45 ежглеяис тгс йубеямгсеыс (теувос еутеяо) 32177
More informationResidential Plumbing BCN 1058
Residential Plumbing BCN 1058 CHAPTER 7 Plumbing Fixtures and Sizing the Drain, Waste, and Vent System MICHAEL KNOTEK 74 Plumbing Fixtures and Sizing the Drain, Waste, and Vent System PLUMBING FIXTURES
More information6. Principles of effective plumbing systems
6. Principles of effective plumbing systems This chapter summarizes the aims and objectives of a good local plumbing system that is, the drinking-water supply that serves a building and the system for
More informationSaferand easierinstallation
EN 85-07 Saferand easierinstallation IföSigninstallationsystem andifösignbuilt-incistern www.ifosanitar.com/sign Aneffectivesolution withmanyadvantages. Ifö Sign installation system makes life a little
More informationFusion-Tech Pipe Multi-Layer Pipe Safety-Pol Fittings
Fusion-Tech Pipe Multi-Layer Pipe Safety-Pol Fittings Professional PP-R Fusion Pipe Solutions for Fluid Handling Systems since 1985 Three Decades of PP-R Fusion Pipe Quality and Reliability Since 1985,
More information2010 Residential Water Heater Replacement Check List
2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This
More informationGeberit Pluvia. Syphonic roof drainage system. Overview Page 42. Geberit Pluvia outlets 6 l. Geberit Pluvia outlets 14 l
Geberit Pluvia Syphonic roof rainage system Description Overview Page 42 Geberit Pluvia outlets 6 l Outlets Page 43 Contact foil Page 43 Outlets Page 44 Geberit Pluvia outlets 14 l eating element Page
More information8.7 Schluter -KERDI-LINE
8.7 Schluter -KERDI-LINE INNOVATIVE SOLUTIONS FOR CERAMIC AND STONE TILE LINEAR DRAINS FOR BONDED WATERPROOFING ASSEMBLIES Application and Function 8.7 Schluter -KERDI-LINE is a low profile linear floor
More informationSECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS
SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials
More informationAlways. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+
Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+ The wall sleeve The wall sleeve a largely unnoticed but very important sealing part. Wall sleeves
More informationDRAINAGE SYSTEMS FOR BEVERAGE INDUSTRIES
DRAINAGE SYSTEMS FOR BEVERAGE INDUSTRIES K E E P I N G U P T H E F L O W S T A I N L E S S S T E E L D R A I N A G E S Y S T E M S BREWERIES & DAIRIES BLÜCHER provides drainage solutions for removing
More informationGeberit Sovent. Installation Guide
Geberit Sovent Installation Guide Drainage for multi-storey building Valid from 1 August 2014 Legal Information Legal Information System design / dimension data This document contains only general, technical
More informationCHAPTER 9 VENTS. copper drainage tube Type DWV, Schedule 40 plastic piping, or borosilicate glass.
CHAPTER 9 VENTS 901 GENERAL 901.1 Scope The provisions of this chapter shall govern the materials, design, construction, and installation of vents. 901.2 Protection of Trap Seals The protection of trap
More informationREGISTRATION EXAMINATION, JUNE 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours
Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 99 REGISTRATION EXAMINATION, JUNE 009 PLUMBING INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time allowed THREE
More information50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance
02/15 Labko GRP cesspools Instructions for installation, operation and maintenance Reliable solutions Wastewater treatment systems Contents 1 LABKO CESSPOOLS... 3 1.1 GENERAL... 3 1.2 IMPORTANT TO KNOW
More informationSTRONG FLEXIBLE. HyperPure PURE
STRONG FLEXIBLE PURE TM HyperPure TM HyperPure 1954 HDPE (HIGH DENSITY POLYETHYLENE) TUBE FIRST TESTED 1965 ENGEL PATENT, PEXa 1967 PEXa PRODUCTION FOR POTABLE WATER SYSTEMS BIMODAL POLYETHYLENE RAISED
More informationATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.
1. Description The macerating system of this unit is installed in a case, specifically designed for horizontal outlet spigots. This macerator is manufactured in a factory which is quality certified to
More informationRoofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.
Roofing Systems There are many different systems, each with it's own special requirements and benefits. Browse through all the options below. BUR (Built-Up Roofing) Built-Up-Roofing, BUR is a roof that
More informationSession 2: Hot Water Supply
MEBS6000 Utility Services http://www.hku.hk/mech/msc-courses/mebs6000/index.html Session 2: Hot Water Supply Dr. Benjamin P.L. Ho Department of Mechanical Engineering The University of Hong Kong E-mail:
More informationRPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
More informationComposite Panel Firewall Systems
Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.
More informationWater Supply (Water Fittings) Regulations 1999
Guidance notes for domestic plumbing systems Water Supply (Water Fittings) Regulations 1999 Information for anyone installing, modifying or maintaining domestic plumbing systems Water Supply Regulations
More informationIntroduction. Contents. General. Materials and workmanship. Diagrams. Other regulations. References
Introduction General This Technical Booklet has been prepared by the Department of the Environment for Northern Ireland and provides for certain methods and standards of building which, if followed, will
More informationWhat to Expect From the Examination. How to Study the Plumbing Codes
Texas State Board of Plumbing Examiners Plumbing Inspector Examination Review Course The following Examination Review Course is designed to assist an applicant in preparing for the Plumbing Inspector examination.
More informationCavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.
CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,
More informationDescription. Outlets Page 62. Contact foil Page 65. Accessories Page 65. Outlets Page 68. Accessories Page 69. Brackets Page 73.
Pluvia Syphonic roof rainage system Description Outlets Page 62 Pluvia outlets 12 l Contact foil Page 65 Accessories Page 65 Pluvia outlets 25 l Outlets Page 68 Accessories Page 69 Pluvia outlets 45/60/100
More informationFIX TURE CARRI ERS. 140(a) MPB-2011-USA
FIXTURE CARRIERS STRUCTURAL FEET The feet are heavy duty cast ductile iron and invertible. No distinction is necessary between right and left hand. Each foot wraps around the specially formed edge of the
More informationSteam System Best Practices Condensate System Piping
Steam System Best Practices Condensate System Piping Summary The best method for improving steam system energy efficiency, reducing chemical costs, and reducing make-up water costs is to return the maximum
More informationIssue of the Guidelines on Prevention of Water Seepage in New Buildings
graphic: Buildings Department Your REF 來 函 檔 號 :. OUR REF 本 處 檔 號 :.BD GR/1-55/173 FAX 圖 文 傳 真 :..28400451 TEL 電 話 :..2626 1717 www.info.gov.hk/bd To : All Authorized Persons 7 March 2005 Registered Structural
More informationSERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)
APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines
More informationS T A I N L E S S S T E E L D R A I N A G E S Y S T E M S
Your drainage specialist K E E P I N G U P T H E F L O W S T A I N L E S S S T E E L D R A I N A G E S Y S T E M S Your drainage specialist Since 1965 BLÜCHER has grown into one of Europe s leading stainless
More informationTop 10+ Mistakes of DWV plumbing design
Top 10+ Mistakes of DWV plumbing design Listed below are the some of the most frequently missed items, noticed by our inspectors, at plumbing rough-in when non-plumbers attempt plumbing design. Most of
More informationPlumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling
Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling February 2001 contents General Information 3 Inspection 4 New Drain and Vent Installations
More informationOld people and nursing homes. Old people and nursing homes, rehab/medical. SPECIAL SOLUTIONS. Security and comfort for every stage of life.
nursing homes. SPECIAL SOLUTIONS. Security and comfort for every stage of life. 401 Model: Eurotrend Care wash basin EN 32, DIN 18024-2 and 18025-2 11-96 (, EN 14688) 1 without overflow, pre-punched tap-hole,
More informationXONYX Solid Surface Owner's Manual
XONYX Solid Surface Owner's Manual 1. IMPORTANT SAFETY CAUTION: Never allow children to use the bath/shower cabin without adult supervision to avoid accidents. CAUTION: Physically challenged people must
More informationSubpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,
4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.
More informationCUBICLE SYSTEMS LTD. CI/SfB 74 X IPS. Pre-plumbed Wall Duct Access Panel System
CUBICLE SYSTEMS LTD CI/SfB 74 X IPS Pre-plumbed Wall Duct Access Panel System ISO 9001:2000 IPS the perfect washroom solution plumbing wall duct panel system and cubicles installed in one operation Cubicle
More informationEUROPLAST S.P.A. 31025 S. LUCIA DI PIAVE - Via Gorizia, 7 - (Tv) - Italy. Tel. +39 0438.4697 - Fax +39 0438.460766. www.europlast.
EUROPLAST S.P.A. 31025 S. LUCIA DI PIAVE - Via Gorizia, 7 - (Tv) - Italy Tel. +39 0438.4697 - Fax +39 0438.460766 www.europlast.it e-mail: europlast@europlast.it 09/05 drainage system EXPORT COMPANY PROFILE
More informationValue Engineering Considerations for Cast Iron Soil Pipe and PVC in Commercial Sanitary and Storm Drainage Applications
Value Engineering Considerations for Cast Iron Soil Pipe and PVC in Commercial Sanitary and Storm Drainage Applications BR-VEC (2-14-13) The Correct Material for the Correct Application Plumbing design
More informationQualification Guide. BPEC 601/2514/7 - Level 1 Diploma in Plumbing Foundation. BPEC 600/9432/1 - Level 2 Diploma in Plumbing Foundation
Qualification Guide BPEC 601/2514/7 - Level 1 Diploma in Plumbing Foundation BPEC 600/9432/1 - Level 2 Diploma in Plumbing Foundation BPEC 600/5270/3 - Level 2 NVQ Diploma in Plumbing and Heating BPEC
More informationPuddle Flange. FRANK Puddle Flange
Puddle Flange FRANK Puddle Flange The problem Problems keep on occurring when connecting pipes during construction work. Pipes laid in the ground must be introduced into concrete walls or shafts. In many
More information1. Geo Vertical 2. Geo Horizontal
1 2 1. Geo Vertical 2. Geo Horizontal 1 2 3 1. Geo Vertical 2. Geo Vertical with towel rail 3. Geo Vertical with cover plate Geo Vertical 47 Geo Vertical Dimensions Connections Range GEVW_Geo Vertical
More informationSolar Pool Heating Proposal
Solar Pool Heating Proposal Swim More with SunCatcher page 1 SunCatcher pool solar heating panels Many thanks for the opportunity to submit our proposal to enhance your swimming pool investment. Our current
More informationRenovation instructions
1(13) Renovation instructions The purpose of these instructions is to inform you of the things to consider when renovating an apartment. You can avoid many possible problems and additional costs following
More informationSolar hot water systems that give energy efficiency a whole new meaning
Solar hot water systems that give energy efficiency a whole new meaning The power to cut your energy bills for years to come When it comes to clean, cost effective energy solutions, the Leda Solar Hot
More informationPlumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling
PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling October 2014 contents General Information
More informationROOF DRAINS TABLE OF CONTENTS
Pictorial Index Product Recommendations Roof Drain Selection Factors Sizing Placement Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations TABLE OF CONTENTS ROOF
More information14. Tools and Software
14. Tools and Software System overview: Geberit welding machine MEDIA 160 and tools... 364 System overview: Geberit welding machine UNIVERSAL 315 and tools... 365 14.1 Tools for Geberit Silent-db20 / Geberit
More informationBIS WC Element / Lyft Alpro
W BIS WC Element / Lyft Alpro BIS WC Frames BIS Walkon BIS Walkon Quattro BIS Walkon Top BIS Walkon Comfort BISMAT VN (Quattro) BIS Control Panel Ellipse / Cube BIS Control Panel Space (BISMAT Top) BIS
More informationFLUSHING CISTERNS. product catalogue
FLUSHING CISTERNS product catalogue 2 Beautiful power of water 5 CONCEALED SYSTEMS 23 FLUSHING PLATES 29 NO-CONTACT FLUSHING 35 EXPOSED FLUSHING CISTERNS 41 SPARE PARTS The line of concealed systems is
More informationPlumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector
Plumbing Helpful Hints Residential Construction Bert Polk Plumbing Inspector Lincoln County 2015 Waste and vent fittings Vent 90 medium 90 long 90 1/16 bend,1/8 bend,1/6 bend, medium 90 san tee combination
More informationAccessible planning and construction
Tiles for Architecture Design 01 01 DIN-certified PRO ARCHITECTURA SINUS trims programme for accessible designs Modular system Coordinated range of system components for flowing transitions without a visible
More information40 ltr Domestic Grease Trap GTO1. 200 ltr Commercial Grease Trap GTO2. Rotational Moulders providing State of the Art Product Design and Developement.
Rotational Moulders providing State of the Art Product Design and Developement. The JFC Grease Trap system is designed: GREASE TRAPS A major problem in the drainage systems of dwelling houses, restaurants,
More information1 DESCRIPTION OF THE APPLIANCE
1 DESCRIPTION OF THE APPLIANCE 1.1 INTRODUCTION The cast iron SF boilers are a valid solution for the present energetic problems, since they can run with solid fuels: wood and coal. These series of boilers
More informationPBX Series Quick Fit Connector Bimetallic Steam Traps
6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
More informationSchluter -KERDI-LINE Elegant, low-profile linear floor drain
Schluter -KERDI-LINE Elegant, low-profile linear floor drain Create an Oasis in the comfort of home Install at walls or intermediate locations Ensure a simple, waterproof drain connection Slope floor on
More informationVisage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1
Visage Digital Digital diverter TM Installation guide Visage Digital diverter installation instructions Page 1 Visage Digital diverter Visage Digital concealed with adjustable and fixed head Visage Digital
More informationHEALTHY LIVING WITH WOOD FIBRE INSULATING MATERIALS
HEALTHY LIVING WITH WOOD FIBRE INSULATING MATERIALS HIGH-QUALITY INSULATION. SUSTAINABLE LIVING. www.homatherm.com Preamble THE EXAMPLE OF NATURE Sustainable living to us means harnessing the forces of
More informationConfort 26. Sliding Systems. Sapa Building System
Confort 26 Sliding Systems Sapa Building System Confort 26 is Sapa s thermally insulated sliding system for windows and doors. Available as two- and three-rail solution. Among its features, there are
More informationCarriers, Fixtures & Piping
Regardless of application and/or installation needs, there are fixture supports available to meet even the harshest design requirements. by William M. Smith Over the years, I m sure that each of you in
More information12.1 Schlüter -KERDI-BOARD
I n n o v a t i v e p r o f i l e s 12.1 Schlüter -KERDI-BOARD S u b s t r a t e U N I V E R S A L S T R U C T U R A L P A N E L, B O N D E D W A T E R P R O O F I N G Application and Function Schlüter
More informationAutomatic Back-Flushing Filter AutoFilt RF9.
Automatic Back-Flushing Filter AutoFilt RF9. AutoFilt RF9 Clearing the Way. The Challenge: In response to the Tier III standard which will come into effect in 2016, the International Maritime Organization
More informationfirst look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders
More informationSchluter -KERDI-BOARD Substrate, building panel, bonded waterproofing
Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing Schluter -KERDI-BOARD The universal substrate for tiles Flat. Level. Plumb. Square. No matter the quality, cost, or extravagance of
More informationBathroom Installation Guide
Bathroom Installation Guide Step-by-step installation of your cabinets We do a lot of groundwork to make it as simple as possible for you to assemble and install your new bathroom furniture yourself. We
More informationPIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT
PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT GENERAL INFORMATION 1.1 This section applies to piping systems for chilled water, hot water, condenser water, steam, condensate return, fuel oil, refrigerant
More informationCAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.
CAST IRON THE BASICS 1. DO NOT LIFT ON YOUR OWN. 2. ONLY LIFT THE RADIATOR VERTICALLY. 3. DO NOT LIFT MORE THAN 8/10 SECTIONS AT ANY ONE TIME. 4. POSITION THE RADIATOR BEFORE FINAL ASSEMBLY. 5. THIS PRODUCT
More informationSTANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2
STANDARD for Plumbing, Heating, Hot Water, Cold Water & Electrical work undertaken by owners within the building known as Sussex Lodge London W2 & 16 Stanhope Terrace London W2 BPME Consulting Engineers
More informationINNOVATIONS. Economic Flat Roof Refurbishment with NOVOPROOF Sealing Systems. A Company of the SAARGUMMI Group
INNOVATIONS Economic Flat Roof Refurbishment with NOVOPROOF Sealing Systems A Company of the SAARGUMMI Group OUR SOLUTION TO REFURBISH ROOFS FOR LONG-TERM DURABILITY Quality and Experience from the Innovation
More informationCardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 info@cardok.com
CARDOK CARLIFT Fast access to underground garages Fast, Silent, Discreet, Design, High-Tech Installation to replace an access ramp on private property Dimensions: (Built to measure, all dimensions can
More informationSTATE BANK OF INDIA.
Page 1 of 5 B SANITARY, PLUMBING & DRAINAGE STATE BANK OF INDIA. PROPOSED RURAL SELF EMPLOYMENT TRAINING INSTITUTE AT RAIGARH IN C.G. DIRECTOR'S BUNGALOW SCHEDULE OF ITEMS-PLUMBING AND SANITARY WORK 1
More informationPlaisance 24. Sliding Systems. Sapa Building System
Plaisance 24 Sliding Systems Sapa Building System Plaisance 24 is Sapa s noninsulated sliding system for windows and doors. Available as one-, two-, three- and fourrail solution. Among its features, there
More informationInstructions for designing heating systems.
Instructions for designing heating systems. In order to obtain the required effect, a lower consumption, a smaller quantity of impurities and improved comfort, heat and domestic hot water installations
More informationFire Resistant Systems
Fire Resistant Systems A R C H I T E C T U R A L A L U M I N I U M G L A Z I N G S Y S T E M S Fire Resistant Systems Introduction Kawneer are pleased to introduce two new comprehensive Fire Resistant
More informationCHAPTER 11 STORM DRAINAGE
CHAPTER STORM DRAINAGE SECTION PC 0 GENERAL 0. Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage. Storm water discharge shall be
More information60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING
60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed
More informationDomestic Wastewater Treatment Up to 6 Population (6PE)
Domestic Wastewater Treatment Up to 6 Population (6PE) www.mjabbott.co.uk Tel: 01722 716361 e-mail: sales@mjabbott.co.uk Fax: 01722 716828 The Solido EN 12566-3 Test Certificate Our system was tested with
More informationMechanical Services Standard Specification 5.0 - Compressed Air Systems. May 2010. For ROYAL HOLLOWAY UNIVERSITY OF LONDON
Mechanical Services Standard Specification 5.0 - Compressed Air Systems May 2010 For ROYAL HOLLOWAY UNIVERSITY OF LONDON Prepared For The Estates Division By: Hulley & Kirkwood Consulting Engineers Ltd
More informationSection 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.
Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice
More informationBuilding Services Engineering Technician
Building Services Engineering Technician A competent Building Services Engineering Technician is expected to be able to demonstrate the following skills and competences: Systems design in the building
More informationWARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING:
WARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING: New Zealand made multi purpose plumbing control for Prison cells Vandal resistant controls Water saving fittings DESCRIPTION Warden 4 is a multi purpose
More informationWelcome: What is U Drain? Drain Materials. Flow
Welcome: Thank you for looking into the U Drain floor drain system. This paper will explore the functional features of the U Drain and why it is superior to other grated systems in the marketplace. We
More informationbuilding applications copper - redefined
building applications copper - redefined copper - redefined The task The development of an innovative tube for the future: economical, environmentally friendly, ecological, completely safe and easy to
More informationThe surface roughness of the polyurethane lining is 10 times lower than cement-lined pipes.
QUALITY INSIDE When it comes to long life piping for drinking water, sewage, industrial water or gas, there is one name that continues to lead the way - ECOPUR by vonroll. Delivering precision-engineered
More informationPLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:
PLATE HEAT EXCHANGER Installation Manual Customer Name: Serial number: Purchase order number: Project: Table of Contents ----------------------------------------------------------------- Page: 2 3 Name
More information