Tepid Water Solutions for you and your customers

Size: px
Start display at page:

Download "Tepid Water Solutions for you and your customers"

Transcription

1 Tepid Water Solutions for you and your customers Thank you for your interest in the Stingray product line. This brochure is a representation of our capabilities, and we encourage you to contact your local Stingray representative to learn more about what Stingray can do for your group.

2 DESIGN CONSIDERATIONS SO WHY TEPID? ANSI Z requires that the water delivered to an emergency plumbing fixture should be TEPID (Appendix B6). Tepid water is NOT cold water! The standard has set the suitable temperature range as being in between 60 F and 100 F. Cold water may provide immediate relief, but prolonged exposure to cold water can result in shock. (a) Tepid water promotes fixture usage. Users need to be able to remain in an emergency fixture for the entire 15 minutes called for by the codes that have adopted ANSI Z358.1 (UPC and IPC), as well as by the MSDS sheets of a product. Users are more likely to use an emergency fixture knowing that tepid water is being supplied rather than straight cold water. Ground water is not the answer as the average ground water across the US is not even tepid. Even in those areas where the average ground water temperature is tepid, remember that this is an average. The best solution is to heat the water and send it through an emergency-mixing valve to insure that you have a year-round tepid solution. Cold Water is defined as being any water temperature under 70 degrees. These cool and cold-water temperatures are enough to drop your body s core temperature significantly. (b) F is still considered a dangerous water temperature since controlling your breathing becomes progressively more difficult as water temperature falls toward 60 F. (c) Air temperature has nothing to do with cold water safety. (a) - ANSI Z (b) - (c) -

3 DESIGN CONSIDERATIONS LEGIONELLA CONCERNS Many if not most cases of nosocomial (hospital acquired) Legionnaires' disease go undetected, and most detected cases are not reported. Therefore, many health care professionals have the false impression that Legionnaires' disease is rare, but it is actually widespread. Legionnaires' disease is contracted by inhaling water droplets containing Legionella. The hot-water system can be a perfect breeding habitat for Legionella. Legionella grow best in water at 95 F to 115 F. Scale and biofilm within tanks, pipes and fixtures add to the problem by providing food and protection for Legionella. Provided by Ron George, CPD, President Plumb-Tech Design and Consulting Services LLC via

4 STINGRAY S9300 SERIES TEPID EMERGENCY SYSTEMS (TES) For Emergency Showers & Combination Eye/Face Wash & Shower Systems ANSI Z Specifications 118 Gallon Tank, 120V/20Amp. Custom sizes available. Water is heated and stored at 180 F Tepid Capacity - 25GPM at 30 psi Cold Water Bypass GPM at 30 psi UL listed tank. Nema 4 rated housing. Requires only a 1 cold water connection. Complete solution as it comes with a Stingray Emergency shower or combination shower eye/face wash system. Features Stingray s SV125 and SV107 thermostatic mixing valves with positive hot water shut-off and integral cold water bypass that exceed ASSE Common power requirements are not a drain on the building s existing system. The Accumulator flattens temperature spikes thought the system. Integral heat trap prevents hot water migration. Available with any of our emergency showers or our combination shower eye/face wash systems. Designed to go through a standard 36 opening door. Benefits Economically meets ANSI Standard Z for emergency shower/eyewash applications. Easy to install for new construction or retrofit. Simple solution when basic water and electricity are the only available resources. Stingray s SV125 and SV107 Valves and Accumulator provide two layers of safety and dependability. Independently Tested And Certified To Comply With ANSI Z

5 STINGRAY S9200 SERIES TEPID EMERGENCY SYSTEMS (TES) For Emergency Eye/Face Wash Systems ANSI Z Specifications 40 Gallon Tank - 120V/20Amp Water is heated and stored at 140 F Tepid Capacity - 7GPM at 30 psi Cold Water Bypass - 5GPM at 30 psi UL listed tank. Nema 4 rated housing. Requires only a 3/4 garden hose connection. Complete solution as it comes with a Stingray Emergency eye/face wash system. Features Stingray s themostatic mixing valve provides positive hot-water-shut-off and integral cold water bypass. Common power requirements are not a drain on the building s existing system. Accumulator flattens temperature spikes thought the system. Integral heat trap prevents hot water migration. Fixture can be attached directly to the system for quick and easy installation. System is capable of being moved from location to location with simple connections. Benefits Economically meets ANSI Standard Z for emergency eye/face wash applications. Easy to install for new construction or retrofit. Simple solution when basic water and electricity are the only available resources. Stingray s SV107 Valve and Accumulator provide two layers of safety and dependability. With the fixture attached to the system prior to shipment, the system will reduce onsite installation time. Independently Tested And Certified To Comply With ANSI Z

6 INTEGRAL MIXING VALVE STINGRAY SERIES T2000-TEPID to the CORE EYE and EYE/FACE WASH ANSI Z Features: Thermostatic Mixing Valve is integrated into the CORE of the eye or eye/face wash system. Thermostatic control at the fixture. Eliminates the need to specify separate mixing valve. Thermostat, eyewash element, and bowl are all easy to maintain and repair independently without total fixture replacement. Centrally located actuator that is located above the bowl for quick and easy access. Available as a wall mounted or pedestal mounted system with all of our options as our standard eye or eye/face wash fixtures. Patented Design The thermostatic element responds to changes in incoming hot and cold water temperatures to provide comfortable, tempered water. Cartridge design allows ease of maintenance and replacement while the fixture is still connected. Positive Hot Water Shut-off Should the cold water supply to the valve fail, the thermostatic element will shut-off all incoming hot water. Integral Cold Water Bypass In the event the thermostatic element fails,or the hot water supply is interrupted, the element will still deliver enough cold water to the emergency eye/face wash equipment to satisfy ANSI s minimum flow rate safety standard. Independently Tested And Certified To Comply With ANSI Z

7 STINGRAY SERIES S2000 EYE & EYE/FACE WASH ANSI Z MODULAR IN DESIGN Patented Quick Switch Element Cutaway View of Element Without Filters Cutaway View of Element With Filters Features Quick Switch Eyewash Element This element is self-draining to deter bacterial growth and is available with optional filters (not strainers) to help capture any particles that may be in your supply water. The Element is manufactured for equalized flow to each spray head and can be easily and quickly removed in order to flush out the supply lines. Flow regulators provide 1.5 gpm for an eyewash and 5 gpm for an eye/face wash. Centrally Located Actuator Our actuator is centrally located above the bowl for easy access, no matter your dominant hand. It also helps keep the unit s footprint compact in size and reduces accidental actuation. Bowls Our ABS bowl is First Aid Red in color to aid in the identification of our fixtures in an emergency situation. It is chemical resistant and easy to maintain. Stainless steel bowls are available should the project require a more robust bowl over ABS. Additional Components Our manifold, supply pipe, and stay-open ball valve are nickel-plated brass for increased durability. Galvanized pipe or stainless steel pipe is used for our pedestal-mounted units. The galvanized pipe can be epoxy coated for an extra layer of protection. ANSI Z358.1 Our fixtures can be bundled together with a properly sized emergency mixing valve in order to provide a complete tepid solution and single source accountability. Universal ANSI compliant signage comes with all of our fixtures. Configurations Our eye and eye/face wash units are available as wall mounted or pedestal-mounted fixtures. Barrier-free configurations are available on all of our fixtures. Independently Tested And Certified To Comply With ANSI Z

8 STINGRAY S3000 SERIES DRENCH SHOWER ANSI Z MO DUL DES AR IN IGN Features Showerheads Our ABS showerhead is First Aid Red in color to aid in the identification of our fixtures in an emergency situation. It is chemical resistant and easy to maintain. Stainless steel showerheads are available should the project require it. Flow Our showerheads are designed to flow at a minimum of 20 gpm. The design of our showerheads provides the user a comfortable, uniform flow over the entire coverage area. Additional Components Our stay-open ball valve is a 1 nickel-plated brass valve for increased durability. Galvanized or stainless steel pipe is used for our shower units. The galvanized pipe can be epoxy coated for an extra layer of protection. We utilize a stainless steel rod as the pull handle to activate our shower fixture. ANSI Z358.1 Our fixtures can be bundled together with a properly sized emergency mixing valve in order to provide a complete tepid solution and single source accountability. Universal ANSI compliant signage comes with all of our fixtures. Configurations Our drench shower units are available as wall mounted, pedestal-mounted, or can come straight down from the ceiling. Barrier-free configurations are available on all of our fixtures. Independently Tested And Certified To Comply With ANSI Z

9 STINGRAY SERIES S5000 COMBINATION DRENCH SHOWER AND EYE/FACE WASH ANSI Z M ODU L DES AR IN IGN Features Bowls & Showerheads Our ABS bowls and showerhead are First Aid Red in color to aid in the identification of our fixtures in an emergency situation. They are chemical resistant and easy to maintain. Stainless steel bowls and/or showerheads are available should the project require it. Flow Our combination shower systems are designed so that both the eye/face wash fixture and the shower fixture can operate at the same time. Our eye/face wash fixture utilizes our Quick Switch Eyewash Element and is designed to flow at a minimum of 3 gpm and provide safe, uniform flow over the entire eye and face area. Our showerheads are designed to flow at a minimum of 20 gpm. The design of our showerheads provides the user a comfortable, uniform flow over the entire coverage area. Additional Components Our manifold, supply pipe, and stay-open ball valves are nickel-plated brass for increased durability. Galvanized or stainless steel pipe is used for our combination units. The galvanized pipe can be epoxy coated for an extra layer of protection. We utilize a stainless steel rod as the pull handle to activate our shower fixture. ANSI Z358.1 Our fixtures can be bundled together with a properly sized emergency mixing valve in order to provide a complete tepid solution and single source accountability. Universal ANSI compliant signage comes with all of our fixtures. Configurations Our drench combination fixtures are available as wall mounted or pedestal mounted systems. Barrier-free configurations are available on all of our fixtures. Independently Tested And Certified To Comply With ANSI Z

10 STINGRAY SYSTEMS MODEL SV160 EMERGENCY MIXING VALVE ANSI Z and EXCEEDS ASSE 1071 COLD WATER BYPASS RATE of psi Features: Built with two powerful liquid thermal motors. Compensates for supply line temperature and pressure changes. Internal cold water bypass upon thermostat failure or hot water failure. Single valve can supply three emergency drench showers and/ or eyewashes. Tamper-resistant control adjustment. Rugged design equipped with stainless steel piston and liner. Valve can recirculate both hot and cold water supply. Easy-maintenance valve can be completely repaired without being removed from the system. Lockout plate and mounting bracket available. Patented Design The Model SV160 s thermostatic element responds to changes in incoming hot and cold water temperatures to provide comfortable, tempered water. Cartridge design allows ease of maintenance and replacement while the valve is still on the supply line. Dual Protection The Model SV160 s twin thermostatic elements respond independently to incoming hot and cold water temperatures and provide backup protection against element failure. In the event one of the thermostatic elements should fail, the Model SV160 will continue to deliver tempered water to the emergency fixtures. Positive Hot Water Shut-off Should the cold water supply to the valve fail, the Model SV160 will shut-off all incoming hot water. Integral Cold Water Bypass In the event the thermostatic element fails, or the hot water supply is interrupted, the SV160 will still deliver enough cold water to the emergency eye/face wash equipment to satisfy ANSI s minimum flow rate safety standard of 40 gpm for two drench showers. High-Low Flow Capability High-low flow capability allows the valve to deliver safe, tempered water to a variety of emergency fixtures supplied by the same water line.

11 STINGRAY SYSTEMS MODEL SV125 EMERGENCY MIXING VALVE ANSI Z and EXCEEDS ASSE 1071 COLD WATER BYPASS RATE of 22 GPM at 30 psi Features: Powerful liquid thermal thermostat. Compensates for supply line temperature and pressure changes. Outlet flow is full cold upon thermostat failure. Inlets can be attached from the bottom. Tamper-resistant control adjustment. Rugged design equipped with stainless steel piston and liner. Valve can recirculate both hot and cold water supply. Easy-maintenance valve can be completely repaired without being removed from the system. Patented Design The Model SV125 s thermostatic element responds to changes in incoming hot and cold water temperatures to provide comfortable, tempered water. Cartridge design allows ease of maintenance and replacement while the valve is still on the supply line. Positive Hot Water Shut-off Should the cold water supply to the valve fail, the Model SV125 will shut-off all incoming hot water. Integral Cold Water Bypass In the event the thermostatic element fails, or the hot water supply is interrupted, the SV125 will still deliver enough cold water to the emergency shower and eye/face wash equipment to satisfy ANSI s minimum flow rate safety standard of 20 gpm for a single drench shower. Low-Flow Capability The Model SV125 can temper water to a wide range of flows to meet your needs. Low-flow capability allows the valve to deliver safe, tempered water to a number of emergency fixtures supplied by the same supply line.

12 STINGRAY SYSTEMS MODEL SV107 EMERGENCY MIXING VALVE ANSI Z and EXCEEDS ASSE 1071 COLD WATER BYPASS RATE of 5 30 psi Features: Powerful liquid filled thermostat. Compensates for supply line temperature and pressure changes. Outlet flow is full cold upon thermostat failure. Tamper-resistant control adjustment. Rugged design equipped with stainless steel piston and liner. Easy-maintenance valve can be completely repaired without being removed from the system. Patented Design The Model SV107 s thermostatic element responds to changes in incoming hot and cold water temperatures to provide comfortable, tempered water. Cartridge design allows ease of maintenance and replacement while the valve is still on the supply line. Positive Hot Water Shut-off Should the cold water supply to the valve fail, the Model SV107 will shut-off all incoming hot water. Integral Cold Water Bypass In the event the thermostatic element fails,or the hot water supply is interrupted, the SV107 will still deliver enough cold water to the emergency eye/face wash equipment to satisfy ANSI s minimum flow rate safety standard of 3 gpm. Low-Flow Capability The Model SV107 tempers water to a wide range of flows to meet your needs. Low-flow capability allows the valve to deliver safe, tempered water to emergency fixtures supplied by the same supply line. The SV107 will safely control water temperature to as little as 2 gpm. Low flow performance means the SV107 is your solution for virtually every emergency eye/face wash fixture application.

13 STINGRAY SERIES ACC400 DRENCH HOSES ANSI Z Features Spray Heads Spray heads are made of soft rubber. Dust Covers The red ABS dust covers protect the spray heads from accumulating dust or debris in between uses. Once the water is activated, the dust covers move out of the way so that the user has unobstructed flow. Finish The drench hoses have a high gloss finish that is easy to maintain and chemical resistant. Control Valve Simply squeezing or pusing on the handle activates the drench hose units. The control valve assembly has no return and shuts off automatically. The dual headed drench hose has a stay open control handle thatnlocks into a stay-open mode once the handle is fully depressed. Additional Components The standard hose for our drench hoses is 5 stainless steel reinforced PVC. Other types of hoses (material and length) are available depending on the application and project requirements. ANSI Z358.1 Our drench hoses can be bundled together with a properly sized emergency mixing valve in order to provide a complete tepid solution and single source accountability. Universal ANSI compliant signage comes with all of our fixtures. Configurations Our drench hoses can be deck mounted, wall mounted, or mounted directly to an emergency plumbing fixture. ANSI Z358.1 In accordance with ANSI Z358.1, a drench hose is considered a supplemental device, unless it meets the flow and pattern of an eye or eye/face wash system, is installed per the location requirements and is able to stay-open. Supplemental devices do not replace other types of emergency equipment.

14 shower_eye wash sign.indd 1 5/19/14 4:07 PM STINGRAY SYSTEMS REPLACEMENT PARTS AND ACCESSORIES Audio and Visual Alarm Systems Full Line of Cabinets Supplemental Drench Hoses Filter Solutions in Quick Switch Element Thermostatic Cartridges Signs Thermometers EM ERGENCY Replacement Showerheads EYE WA SH Replacement ABS Bowl Assemblies Replacement S/S Bowl Assemblies

15 shower_eye wash sign.indd 1 5/19/14 4:07 PM ANSI Z OVERVIEW The valve for an emergency shower shall remain open without the use of the operator s hands until intentionally closed. The valve shall be simple to operate and shall go from off to on in one second or less. Emergency showers shall provide a flushing fluid column that is at least 82 and not more than 96 in height from the surface on which the user stands. Emergency showers shall be capable of delivering flushing fluid at minimum of 20gpm for a minimum of 15 minutes. The spray pattern shall have a minimum diameter of 20 at 60 above the surface on which the user stands. Eye/face washes shall be capable of delivering flushing fluid to the eyes and face at not less than 3gpm for 15 minutes. Activator shall be easy to locate and readily accessbile to user. Eye/face washes shall provide flushing fluid to both eyes simultaneously. The flushing fluid shall cover the areas between the interior and exterior of the gauge at some point less than 8 above the eyewash nozzles (Refer to Illustration 7 in the Standard). Flushing spray heads shall be positioned 33 to 45 inches from floor, and a minimum of 6 inches from nearest wall or obstruction. Nozzles and flushing units shall be protected from airborne contaminants. The valve for an eye/face wash shall remain open without the use of the operator s hands until intentionally closed. The valve shall be simple to operate and shall go from off to on in one second or less. Document Purpose: Provide key points for assisting compliance with ANSI provisions which relate to emergency equipment. The ANSI Z standard establishes minimum performance and use requirements for eyewash and shower equipment for the emergency treatment of the eyes or body of a person who has been exposed to hazardous materials. Installation Considerations Emergency fixtures shall be constructed of materials that will not corrode in the presence of the flushing fluid. Emergency fixtures shall be in accessible locations that require no more than 10 seconds (approximately 55 feet) to reach. Emergency fixtures shall be located on the same level as the hazard and the path of travel shall be free of obstructions. Employees who may be exposed to hazardous materials shall be instructed in the location and proper use of the emergency fixtures. Emergency fixtures shall be activated on a weekly basis and inspected annually to conform with the requirements of the standard. Each part of a combination unit shall be certified individually and when activated simultaneously be in accordance with the procedures associated for the specific component. Emergency fixtures shall be located in an area identified with a highly visible sign and be in a well-lit area. A means shall be provided to ensure that a controlled flow of flushing fluid is provided at a velocity low enough to be non-injurious to the user.

16 FIRMS REPRESENTING STINGRAY SYSTEMS BRAHAN 7685 Fields Ertel Road, C1 Cincinnati, OH (513) DELLON SALES 5 Albertson Avenue Albertson, NY (516) DELTA Q 510 East Jamie Avenue La Habra, CA (714) EVANS & ASSOCIATES 1650 Redi Road, Suite 400 Cumming, GA (678) FLUID SYSTEMS 1210 Vermeer Cove Cordova, TN (901) IDC ASSOCIATES 5717 West 6th Avenue Lakewood, CO (303) J. R. BAKER ASSOCIATES 6901 Herman Road Syracuse, NY (315) JAMES M. PLEASANTS 603 Diamond Hill Court Greensboro, NC (800) JENSEN SALES & MARKETING 5026 West Amelia Earhart Drive Salt Lake City, UT (801) L&R ASSOCIATES 2262 North Penn Road Hatfield, PA (800) MCGUIRE GROUP 1019 Sweetbriar Road Orlando, FL (407) R.L. DEPPMANN Bridge Street Southfield, MI (248) SMS 1650 McEwen Drive Whitby Ontario, Canada L1N 0A2 (877) SPECIFIED DESIGN CONSULTANTS Portal Road, Suite 500 La Vista, NE (402) THERMOFLO 3233 Babcock Boulevard Pittsburgh, PA (412) VCM SALES 1435 West Church Street, #1 Jacksonville, FL (904)

ANSI / ISEA Z358.1-2014 Compliance Checklist

ANSI / ISEA Z358.1-2014 Compliance Checklist ANSI / ISEA Z358.1-2014 Compliance Checklist INTRODUCTION The selection of emergency eyewash and shower equipment is often a complicated process. In addition to addressing design and engineering issues,

More information

Design Requirements for Eyewash and Safety Shower Units APPLICATION: Detailed Installation, Operation and Design. Eyewash Stations.

Design Requirements for Eyewash and Safety Shower Units APPLICATION: Detailed Installation, Operation and Design. Eyewash Stations. APPLICATION: Eyewash Stations must be provided in the following areas. Laboratories Plumbed emergency eyewash equipment shall be installed in every lab or room, where an MSDS for the materials used specifies

More information

Emergency Showers and Eyewashes Mike Adkins Wednesday, October 31, 10:00-11:1511:15 a.m.

Emergency Showers and Eyewashes Mike Adkins Wednesday, October 31, 10:00-11:1511:15 a.m. Emergency Showers and Eyewashes Mike Adkins Wednesday, October 31, 10:00-11:1511:15 a.m. Safety First! How to Specify Emergency Showers and Eyewashes Presented by Mike Adkins, Guardian Equipment. ASPE

More information

15430 SAFETY SHOWERS AND EYEWASHES

15430 SAFETY SHOWERS AND EYEWASHES 15430 SAFETY SHOWERS AND EYEWASHES PART 1: GENERAL 1.01 RELATED SECTIONS 01005 - ENVIRONMENTAL HEALTH 11600 LABORATORY EQUIPMENT 15020 - LABORATORIES 15130 - PIPING SPECIALITES 15400 - PLUMBING 15420 -

More information

B. Shop Drawings: Diagram power, signal, and control wiring.

B. Shop Drawings: Diagram power, signal, and control wiring. SECTION 224500 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Emergency showers. 2. Eyewash equipment. 3. Eye/face wash equipment. 4. Combination units. 5. Water-tempering equipment. 1.2 SUBMITTALS

More information

112039.00 224500 EMERGENCY PLUMBING FIXTURES

112039.00 224500 EMERGENCY PLUMBING FIXTURES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following emergency plumbing fixtures: 1. Emergency showers. 2. Eyewash equipment. 3. Eye/face wash equipment. 4. Hand-held drench hoses. 5. Combination

More information

DECONTAMINATION PRODUCTS

DECONTAMINATION PRODUCTS DECONTAMINATION PRODUCTS AXION MSR TM EYE/FACE WASH UNITS SHOWERS :: COMBINATION UNITS This catalog represents a snapshot of the emergency response equipment that Haws offers. For more details and a comprehensive

More information

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version) BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version) Bradley Halo Emergency Plumbing Fixtures are a new generation in safety equipment, featuring separate supply and waste piping to eye/face wash,

More information

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities. SECTION 224500 - EMERGENCY PLUMBING FIXTURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities. SECTION 22 45 00 - (ADD#2) PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

When Safety Comes First. Emergency Safety Shower and Eye Wash Catalogue

When Safety Comes First. Emergency Safety Shower and Eye Wash Catalogue When Safety Comes First Emergency Safety Shower and Eye Wash Catalogue No industry, irrespective of its size or its function, can afford to neglect the safety of its personnel and the general public. Advances

More information

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

BRADLEY HALO EMERGENCY PLUMBING FIXTURES BRADLEY HALO EMERGENCY PLUMBING FIXTURES Bradley Halo Emergency Plumbing Fixtures are a new generation in safety equipment, featuring separate supply and waste piping to eye/face wash, ergonomic hand activation

More information

When Safety Comes First. Emergency Safety Shower and Eye Wash Catalogue

When Safety Comes First. Emergency Safety Shower and Eye Wash Catalogue When Safety Comes First Emergency Safety Shower and Eye Wash Catalogue No industry, irrespective of its size or its function, can afford to neglect the safety of its personnel and the general public. Advances

More information

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities. SECTION 224500 - EMERGENCY PLUMBING FIXTURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

FIRING RANGE PHASE 1 DESIGN 224500-1

FIRING RANGE PHASE 1 DESIGN 224500-1 FIRING RANGE PHASE 1 DESIGN 224500-1 SECTION 224500 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

STANDARD OPERATING PROCEDURE EMERGENCY EYEWASH AND SHOWER EQUIPMENT

STANDARD OPERATING PROCEDURE EMERGENCY EYEWASH AND SHOWER EQUIPMENT STANDARD OPERATING PROCEDURE EMERGENCY EYEWASH AND SHOWER EQUIPMENT 1.0 PURPOSE 2.0 SCOPE 2.1 PLUMBED EYEWASH UNIT 2.2 EMEMERGENCY SHOWER 3.0 DEFINITIONS 4.0 RESPONSIBILITIES 4.1 OFFICE OF ENVIRONEMNTAL

More information

EMERGENCY EYEWASH AND SHOWERS 29 CFR Part 1910.151 (c)

EMERGENCY EYEWASH AND SHOWERS 29 CFR Part 1910.151 (c) 29 CFR Part 1910.151 (c) This General Regulation Is As Follows: "Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing

More information

Therm-Omega-Tech, Inc. Therm-Omega-Tech, Inc. MODEL EMV. A Heavy Duty, Reliable Source For Tepid Water Delivery. Model EMV

Therm-Omega-Tech, Inc. Therm-Omega-Tech, Inc. MODEL EMV. A Heavy Duty, Reliable Source For Tepid Water Delivery. Model EMV MODEL EMV Emergency Safety Shower Water Heater Tepid Water For Emergency Safety Shower/Eyewash Stations Features Heavy Duty Construction Hydrastone cement lining provides tank longevity Copper-silicon

More information

Emergency Showers and Eyewash Stations

Emergency Showers and Eyewash Stations Emergency Showers and Eyewash Stations Here is a guide regarding what types and specifications are required when selecting an emergency Shower and/or eyewash station. Why are emergency showers or eyewash

More information

EMERGENCY EYEWASH & SHOWER EQUIPMENT SELECTION, INSTALLATION & USE GUIDE

EMERGENCY EYEWASH & SHOWER EQUIPMENT SELECTION, INSTALLATION & USE GUIDE EMERGENCY EYEWASH & SHOWER EQUIPMENT SELECTION, INSTALLATION & USE GUIDE FOREWORD The need for emergency eyewash and shower devices is real. 15,110 U.S. workers were afflicted by chemical exposures in

More information

EMERGENCY SHOWERS AND EYEWASH STATIONS

EMERGENCY SHOWERS AND EYEWASH STATIONS EMERGENCY SHOWERS AND EYEWASH STATIONS EMERGENCY SHOWERS AND EYEWASH STATIONS Thousands of New Brunswickers work near hazardous chemicals every day. Although safety practices have improved over the years,

More information

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER 1.800.591.9360 TECHNICAL ASSISTANCE FAX: 1.626.855.4894

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER 1.800.591.9360 TECHNICAL ASSISTANCE FAX: 1.626.855.4894 ACORN SAFETY P.O. BOX 3527 CITY OF INDUSTRY, CA 9744-0527 UNITED STATES OF AMERICA WWW.ACORNSAFETY.COM INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FREEZE RESISTANT WALL MOUNTED EMERGENCY EYEWASH

More information

Commercial Electric Water Heater

Commercial Electric Water Heater Commercial Electric Water Heater Provides Tepid Water For Emergency Fixtures Features Heavy Duty Construction Hydrastone cement lining provides tank longevity Copper-silicon alloy tappings cannot rust

More information

Effective Date: January 1, 2009

Effective Date: January 1, 2009 Lawler Manufacturing 2009 List Price Sheet (valid in SK, MB, ON and QC only) Effective Date: January, 2009 c=00 m=72 y=0 b=6 For more information contact www.dobbinsales.com Go to www.lawlervalve.com to

More information

EMERGENCY EYE WASH FACILITY POLICY. Under the Occupational Health and Safety Regulations of the Province of Newfoundland and Labrador

EMERGENCY EYE WASH FACILITY POLICY. Under the Occupational Health and Safety Regulations of the Province of Newfoundland and Labrador EMERGENCY EYE WASH FACILITY POLICY Under the Occupational Health and Safety Regulations of the Province of Newfoundland and Labrador References to emergency eyewash facilities and emergency washing facilities

More information

Light Duty Commercial Electric Water Heater

Light Duty Commercial Electric Water Heater Features Heavy Duty Construction Hydrastone cement lining provides longer tank life Copper-silicon tappings cannot rust or corrode High impact composite jacket eliminates damage during installation and

More information

OREGON FIRE CODE Interpretations and Technical Advisories

OREGON FIRE CODE Interpretations and Technical Advisories OREGON FIRE CODE Interpretations and Technical Advisories A collaborative service by local and state fire professionals, along with our stakeholders and customers, to provide consistent and concise application

More information

Domestic Hot Water Systems and Plumbing Products

Domestic Hot Water Systems and Plumbing Products Domestic Hot Systems and Plumbing Products Taco Catalog #100-117 Effective Date: 09/02/15 Supersedes: 06/22/15 Printed in USA Domestic Hot Recirculation Taco Domestic Hot Plumbing Products Since 1920 Taco

More information

World Leader in Emergency Eye Care

World Leader in Emergency Eye Care Emergency Eyewash 2013 CATALOG WHAT S INSIDE World Leader in Emergency Eye Care 115 Primary Eyewash Device 117 Secondary Eyewash Device 118 Personal Eyewash Bottles 119 Wall Stations 120 Refills 121 Accessories

More information

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

ELECTRIC/DIESEL FIRE PUMP CHECK LIST BUILDING NAME: DESIGNER: SCO REPRESENTATIVE: PUMP MANUF.: LOCATION: INSTALLER: DATE: OWNER NAME: INSTALLATION Certificate for flushing and hydrostatic test furnished Piping been hydrostatically tested

More information

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715, 4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.

More information

Medical Air Systems: Scroll

Medical Air Systems: Scroll GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing

More information

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................

More information

Arapahoe County Residential Water Heater Installation and Inspection Guide

Arapahoe County Residential Water Heater Installation and Inspection Guide Arapahoe County Residential Water Heater Installation and Inspection Guide The attached handout is designed to be a general permit submittal and inspection guide covering most installation instances, however

More information

Section 4 EMERGENCY EYEWASH AND SAFETY SHOWER EQUIPMENT

Section 4 EMERGENCY EYEWASH AND SAFETY SHOWER EQUIPMENT Section 4 EMERGENCY EYEWASH AND SAFETY SHOWER EQUIPMENT Contents A. Scope 4-2 B. Applications 4-2 C. Equipment Requirements 4-3 D. Testing and Commissioning 4-4 E. References 4-5 4-1 A. Scope This guide

More information

OPERATION & MAINTENANCE MANUAL PRELIMINARY STEPS: 1. Flush water supply line prior to installation. This will remove unwanted debris from the lines and prevent unwanted blockages in the safety equipment.

More information

How Compliant is Your Emergency Shower and Eyewash? What Managers Need to Consider about Australian Standard Compliance

How Compliant is Your Emergency Shower and Eyewash? What Managers Need to Consider about Australian Standard Compliance How Compliant is Your Emergency Shower and Eyewash? What Managers Need to Consider about Australian Standard Compliance Introduction Despite every precaution to prevent them occurring, accidents happen.

More information

BLADDER SURGE CONTROL SYSTEM

BLADDER SURGE CONTROL SYSTEM PART I GENERAL 1.01 Description BLADDER SURGE CONTROL SYSTEM This specification describes the requirements for a Bladder Surge Control System. The purpose of the system is to minimize transient pressures

More information

Element D Services Plumbing

Element D Services Plumbing Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.

More information

FLASH TANK ECONOMIZER PRODUCT GUIDE

FLASH TANK ECONOMIZER PRODUCT GUIDE FLASH TANK ECONOMIZER PRODUCT GUIDE Overview A flash tank is used to recover blowdown energy in the form of flash steam and blowdown. This can only be used with a deaerator or some other pressurized device.

More information

American National Standard for Fixed and Portable Decontamination Shower Units

American National Standard for Fixed and Portable Decontamination Shower Units Revision of ANSI/ISEA 113-2008 American National Standard for Fixed and Portable Secretariat International Safety Equipment Association Approved American National Standards Institute, Inc. American National

More information

WINTERIZING YOUR HOME PLUMBING AT BLUE RIDGE SHORES

WINTERIZING YOUR HOME PLUMBING AT BLUE RIDGE SHORES WINTERIZING YOUR HOME PLUMBING AT BLUE RIDGE SHORES The following are suggestions to help you winterize your home plumbing. They are for homes where the heat is not left on during the winter months. There

More information

HL Series - Commercial Heaters Tankless Water Heating Solutions

HL Series - Commercial Heaters Tankless Water Heating Solutions HL Series - Commercial Heaters 5-18 kw (17,000-61,400 BTUs) Low flow activation options at.15 and.25 GPM (0.6 and 0.9 L-Min) Certified Lead-Free Design Variable Temp Heat Exchanger Pressure Drop Advantage

More information

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage

More information

How To Make A Combination Shower

How To Make A Combination Shower emergency showers, eyewash and decontamination solutions emergency showers eye and eye/face washes portable and self-contained laboratory safety decontamination systems WWW.ENWARE.COM.AU when seconds count

More information

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing) CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.

More information

What is Thermal Expansion?

What is Thermal Expansion? What is Thermal Expansion? When water is heated it expands. For example, water heated from 90ºF to a thermostat setting of 140ºF in a 40 gallon hot water heater will expand by almost one-half gallon. This

More information

Installation S19-220PT S19-220BPT. Wall-Mounted Eyewash with Plastic Bowl. Wall-Mounted Eyewash with Stainless Steel Bowl.

Installation S19-220PT S19-220BPT. Wall-Mounted Eyewash with Plastic Bowl. Wall-Mounted Eyewash with Stainless Steel Bowl. Wall-Mounted Eyewash with Plastic Bowl Wall-Mounted Eyewash with Stainless Steel Bowl Table of Contents Pre- Information................ Instructions.................... Components and Parts List.......

More information

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

Electronic Wallmount Faucet 1500T4 & 1501T4 Series

Electronic Wallmount Faucet 1500T4 & 1501T4 Series Electronic Wallmount Faucet 1500T4 & 1501T4 Series Specification: (example) Battery (4 C cell) or Hardwire (24 VAC) infrared electronic handwash system H 2OPTICS technology no external adjustments required

More information

See Mixing Valve Catalog (PHBRMIX) for more detailed information about the products in this section.

See Mixing Valve Catalog (PHBRMIX) for more detailed information about the products in this section. See Mixing Valve Catalog (PHBRMIX) for more detailed information about the products in this section. MIXING VALVES Hydronic Tempering Valves TV (34-200) SERIES MIXING VALVES These dependable thermostatic

More information

Section 1.2 EMERGENCY EYEWASH AND SAFETY SHOWER EQUIPMENT TABLE OF CONTENTS. Page A. Regulations, Consensus Standards, and References 1.

Section 1.2 EMERGENCY EYEWASH AND SAFETY SHOWER EQUIPMENT TABLE OF CONTENTS. Page A. Regulations, Consensus Standards, and References 1. Section 1.2 EMERGENCY EYEWASH AND SAFETY SHOWER EQUIPMENT TABLE OF CONTENTS Page A. Regulations, Consensus Standards, and References 1.2-2 B. Scope 1.2-2 C. Application 1.2-2 D. Location 1.2-4 E. Performance

More information

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS January 1997 PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS 1.0 PERMIT 1.1 After receipt of a Building Permit from the City of San Jose Building Department, submit

More information

How To Fix A Leaky Water Heater

How To Fix A Leaky Water Heater Preventing water damage caused by plumbing fixtures Thousands of home insurance claims are filed every year. Some losses are major, others aren t, but they re always inconvenient and usually avoidable!

More information

In-Line Air Separators

In-Line Air Separators Air Elimination & Control In-Line Air Separators The AC models of air separators deliver all the quality and performance you expect from Taco products. They are built to last with shell, heads and ANSI

More information

Fiberstars Mini Lighted Laminar Flow Fountains

Fiberstars Mini Lighted Laminar Flow Fountains Fiberstars Mini Lighted Laminar Flow Fountains SAVE THESE DIRECTIONS! These directions are provided to ensure the proper installation and operation of Fiberstars Mini Lighted Laminar Flow Fountain. The

More information

NAVIEN AMERICA INC. 17855 FITCH AVENUE

NAVIEN AMERICA INC. 17855 FITCH AVENUE Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:

More information

SHOWERS 85-100 SHOWERS

SHOWERS 85-100 SHOWERS SHOWERS 85-100 85 SHOWERS SHOWER HEADS 87 NEPTUNE 89 SHOWER PANEL SERIES PERFECT TIME SHOWER PANEL SERIES 91 NEPTUNE 1042T 93 PERFECT TIME 1042T 94 NEPTUNE MEDICAL 95 TOUCH SH 1000T 96 NEPTUNE 1032 97

More information

Morrison Bros. Co. General Product Specifications

Morrison Bros. Co. General Product Specifications Morrison Bros. Co. General Product Specifications Tank Mounted Spillbox The spill containment device is manufactured to contain spills and drips that may occur at the fill point on aboveground storage

More information

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description Worldwide Contacts www.tyco-fire.com Model F thru F3 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description The Mulsifyre Nozzles are open (nonautomatic) nozzles and they are designed

More information

Electric Water Heater

Electric Water Heater Electric Water Heater Operation and Installation Manual (LIMITED WARRANTY AND TANK REPLACEMENT POLICY) The following information should be noted at time of installation and retained for future reference.

More information

Element D Services Plumbing

Element D Services Plumbing PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses domestic cold, hot and hot water return distribution systems within and to five feet beyond building perimeter. PART 2 - DESIGN CRITERIA 2.01 GENERAL

More information

Emergency Eyewash and Drench Shower Program

Emergency Eyewash and Drench Shower Program Emergency Eyewash and Drench Shower Program Document Number: Effective Date: Revision Date: 7-24-14 1.0 Purpose and Applicability 1.1 The purpose of this program is to ensure that all safety eyewashes

More information

BERMAD Fire Protection

BERMAD Fire Protection 400E-2M/700E-2M IOM Bermad Electrically Controlled Deluge Valve with EasyLock Manual Reset Model: 400E-2M/700E-2M INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD 400E-2M/700E-2M Bermad

More information

Watts Pure Water Systems

Watts Pure Water Systems Watts Pure Water Systems WM-120-PT Installation and Operation Manual Premier Water Systems Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before

More information

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

TANKLESS WATER HEATER INSTALLATION DIAGRAMS TANKLESS WATER HEATER INSTALLATION DIAGRAMS Installation Diagrams Tankless Installation / Optional Return Small 10-15 Gallon Point-of-Use Water Single and Optional Return : One single, small capacity water

More information

BERMAD Fire Protection

BERMAD Fire Protection Model: 400E-2M BERMAD Electrically Controlled Deluge Valve with Easy Lock Manual Reset Installation Operation Maintenance Safety First BERMAD believes that the safety of personnel working with and around

More information

Commercial Gas Water Heater

Commercial Gas Water Heater Commercial Gas Water Heater 3-Year Limited Tank/1-Year Limited Parts Warranty* The Polaris has a high grade 444 stainless steel tank with brass connections for years of dependable, trouble-free service

More information

Section 43. Lead Paint Risk Factor NONE WATER HEATER STORAGE ELECTRIC

Section 43. Lead Paint Risk Factor NONE WATER HEATER STORAGE ELECTRIC WATER HEATER STORAGE ELECTRIC Lead Paint Risk Factor NONE TABLE OF CONTENTS PART 1: INSTALLATION REQUIREMENTS FOR CONVENTIONAL HOMES... 1 WATER HEATER REPAIRS... 1 1. APPLIANCE REPAIR... 1 WATER HEATER

More information

ETL listed for installations within 5 ft. (1.5M) of outer edge of water www.srsmith.com 79-15152-00 Rev E2 9.14 Page 1 of 10

ETL listed for installations within 5 ft. (1.5M) of outer edge of water www.srsmith.com 79-15152-00 Rev E2 9.14 Page 1 of 10 Color Light Streams Large Laminar Installation Manual (CLSLL) Input Power: Total Power: 12V AC 5W 4008814 ETL listed for installations within 5 ft. (1.5M) of outer edge of water 79-15152-00 Rev E2 9.14

More information

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression

More information

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.

More information

2010 Residential Water Heater Replacement Check List

2010 Residential Water Heater Replacement Check List 2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This

More information

Safety & Risk Management Policies and Procedures

Safety & Risk Management Policies and Procedures Safety & Risk Management Policies and Procedures Title: Emergency Eye Wash & Shower Policy Date: August 2013 Rationale: The Occupational Safety and Health Administration (OSHA 29CFR 1910.151) requires

More information

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual STATFlow Direct-to-Drain System For use with STATIM 2000 and STATIM 5000 Autoclaves Installation Guide and Operator s Manual STATFlow Installation Guide and Operator s Manual 95-113193 Rev 2.0. Copyright

More information

PLUMBING & CROSS-CONNECTION CONTROL

PLUMBING & CROSS-CONNECTION CONTROL PLUMBING & CROSS-CONNECTION CONTROL. MODULE 4 VII. Typical Retail Food Service Cross-Connections VIII. Air Gaps and Air Breaks for Drains and Waste IX. Grease Interceptors VII. TYPICAL RETAIL FOOD SERVICE

More information

Installation Instructions 4662.003

Installation Instructions 4662.003 Installation Instructions.00 SINGLE CONTROL KITCHEN FAUCET Thank you for selecting American-Standard...the benchmark of fine quality for over 00 years. To ensure that your installation proceeds smoothly--please

More information

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual Speedflow Undersink Unvented Water Heater Models SF10K and SF15K Instruction Manual Version 2.0 May 2009 Hyco SpeedFLOW UnVENTED WATER HEATER Models SF10K (10 Litres) and SF15K (15 Litres) 1. Introduction

More information

STABITHERM INSTALLATION & SERVICE BOOKLET

STABITHERM INSTALLATION & SERVICE BOOKLET STABITHERM INSTALLATION & SERVICE BOOKLET TABLE OF CONTENTS Introduction...3 Warranty...3 Product Range and Physical Description...4 Method of Operation...5 Recommended Pressures and Temperatures...6 Flow

More information

Fixtures - Parts - Accessories to shampoo bowls

Fixtures - Parts - Accessories to shampoo bowls Page 1??? - For what brand of bowl do you need parts??? Find out by looking on the bottom of the bowl, between the front and strainer, where molded in the bottom is the brand and model number. For example,

More information

SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA 95728-1039 (7300 Short Road, Serene Lakes)

SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA 95728-1039 (7300 Short Road, Serene Lakes) SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA 95728-1039 (7300 Short Road, Serene Lakes) Maintenance Office Administrative Office Billing Office 530-426-7802 530-426-7800 916-332-4872

More information

Montgomery County Health Department Mobile Food Guidelines. Definitions

Montgomery County Health Department Mobile Food Guidelines. Definitions Montgomery County Health Department Mobile Food Guidelines Definitions Commissary A permitted food establishment to which a mobile unit returns on a daily basis for such tasks as discarding liquid and/or

More information

Cost Savings Gained through Rotary Impingement Tank Cleaning

Cost Savings Gained through Rotary Impingement Tank Cleaning Gamajet Cleaning Systems, Inc. Exton, Pennsylvania August 2012 Cost Savings Gained through Rotary Impingement Tank Cleaning Abstract: Specific case studies on the benefits of rotary impingement and CIP

More information

22 12 00 FACILITY POTABLE WATER STORAGE TANKS

22 12 00 FACILITY POTABLE WATER STORAGE TANKS DIVISION 22 PLUMBING 22 11 16 DOMESTIC WATER PIPING 22 11 19 DOMESTIC WATER PIPING SPECIALTIES 1. To facilitate landscape and other maintenance operations, exterior hose bibs shall be provided at 50 foot

More information

WARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING:

WARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING: WARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING: New Zealand made multi purpose plumbing control for Prison cells Vandal resistant controls Water saving fittings DESCRIPTION Warden 4 is a multi purpose

More information

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS SECTION 1001 GENERAL 1001.1 Scope. This chapter shall govern the installation, alteration and repair of boilers, water heaters and pressure vessels.

More information

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering Model: 400E-2M Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset Installation Operation Maintenance Application Engineering BERMAD 1. Safety First BERMAD believes that the safety

More information

Technical Update TAA.TU.11093 Rev. 1

Technical Update TAA.TU.11093 Rev. 1 http://www.gambro.com/en/usa_tech/ 800-525-2623 303-222-6500 Technical Update TAA.TU.11093 Rev. 1 Effective: 05 APR 2013 CO# 13084 Product: Subject: From: Phoenix Dialysis System Required Electrical Safety

More information

www.garrisonwaterheaters.com Electric & Gas Water Heaters

www.garrisonwaterheaters.com Electric & Gas Water Heaters www.garrisonwaterheaters.com Electric & Gas Water Heaters Hot Water: Take it for Granted with Garrison According to the U.S. Department of Energy, the average American home uses 64 gallons of hot water

More information

Installation Instructions

Installation Instructions Installation Instructions E19-120 (Plastic showerhead) E19-120A (Stainless steel showerhead) E19-120SS (All Stainless Steel) Drench Shower - Horizontal Supply Table of Contents Pre-Installation Information..........................2.............................3

More information

SF15K SF05KSS, SF10KSS

SF15K SF05KSS, SF10KSS Product Instruction Manual Speedflow SF05K, SF10K & SF15K SF05KSS, SF10KSS & SF15KSS Undersink unvented water heater V15.6/6 Version 3.2 Jan 2015 Thank you for purchasing a Hyco Speedflow unvented water

More information

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! Atlanta (Monroe) GA 770-267-3787 gpm@gpmhydraulic.com www.gpmhydraulic.com What You Don t Know About Hydraulic Accumulators Can Kill You TABLE OF CONTENTS

More information

Manufactured in the UK for worldwide distribution

Manufactured in the UK for worldwide distribution Manufactured in the UK for worldwide distribution 316 Stainless Steel Construction All our safety products are engineered from 316 Stainless Steel which resists corrosion. We do not use any coating or

More information

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide Water Circulation Pumps & Circulators Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide Taco Catalog # 100-41 Supersedes: 08/07/15 Effective Date: 09/01/15 Printed in

More information

New or Remodeled Food Service Establishment Checklist**

New or Remodeled Food Service Establishment Checklist** ToTo Protect and Promote the Health and the Environment of the People of Kittitas County New or Remodeled Food Service Establishment Checklist** **Some items may not be required for limited food service

More information

Ceiling Mount Air Handler Manual

Ceiling Mount Air Handler Manual www.surna.com 303.993.5271 Ceiling Mount Air Handler Manual Models: CMAH12, CMAH18, CMAH24, CMAH30, CMAH36, CMAH48, CMAH60 Revised: September 2014 Table of Contents Warranty Information 4 Limited Warranty

More information

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459 SECTION 15459 PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work

More information

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line

More information