SmartRouters Optionally with Bus Diagnostics RTRS RTRSD

Size: px
Start display at page:

Download "SmartRouters Optionally with Bus Diagnostics RTRS RTRSD"

Transcription

1 SmartRouters Optionally with Bus Diagnostics RTRS RTRSD Data Sheet

2 The present instruction is intended to support you concerning installation and use of the device. The information has been composed with high diligence. We accurately checked the document s content based on the described hard- and software. However, we cannot exclude potential divergences. For this reason we do not assume liability for errors that may be contained in this description and in exemplary software provided if necessary. The devices and their respective documentation are subject to modification. All information contained in the document undergo a regularly checkup and necessary corrections will be incorporated in the following editions. We would appreciate your comments and suggestions. For more detailed information such as further descriptions, texts for invitation of tenders of devices and available software visit our website We would be happy to send it to you upon request. The device warranty will be terminated in case of inappropriate handling, dismantling of the unit use of software not released by SysMik for the respective device. Set-up and operation of the unit has exclusively to be effected under consideration of the applying safety regulations and by qualified staff.

3 Overview Routers are devices enabling a logical and physical structuring of networks. RTRS and RTRSD are standard LONWORKS router based on the router core module RTR-10 by Echelon, thus ensuring compatibility and LONMARK conformity. The routers include two network interfaces with a LON transceiver each. The A side of the router has always a TP/FT10 transceiver while the router s B-side can optionally be equipped with a TP/FT10 or a TP/XF1250 transceiver. SmartRouters with TP/FT10 transceivers are compatible with LPT-10 (Link Power Transceiver) allowing the use within LPT10 networks. The RTRSD SmartRouter with diagnostics function includes an additional diagnostics node on the A side (NET A) to monitor the channel there. Which are the tasks solved by the Diagnostics Node of the RTRSD? Monitoring of the ring topology Supervision of the communication with the nodes in the network segment Evaluation of the channel s transmission quality by monitoring and logging of channel load and error frequency Voltage supervision in Link Power segments The diagnostics node can be used as monitoring tool for Free Topology and Link Power networks. Ring shaped structures are used in order to achieve increased safety by redundancy within the communication channels.

4 Terminator Terminator NET A A1 A2 1) Transceiver Side A RTR-10 Transceiver Side B B1 NET B B2 RING A RA1 RA2 Link Power Monitoring 1) Diagnostics Node 1) Power Supply 230V AC 24V AC/DC 2) 1) only RTRSD 2) only devices with 230V AC power supply Fig. 1: Function survey and components of the SmartRouter Note: Even if a diagnostics node is included, the A side is only equipped with one physical transceiver. However, when comissioning with LNS tools such as LonMaker, two credits are needed for the A side!

5 Connections only RTRSD 230V devices only RING A RA1 RA2 230V AC L N Service Diag. COM CRC Dresden GmbH RING Test Smart Router + Bus Diagnostics RTRSD-TP/FT10-TP/FT10 230V PWR PKT Service Router A B Termination ,3 Double Single NET A A1 A2 SH DIAG NET A DIAG NET B NET B B1 B2 SH Termination NET A NET B AC/DC +24V GND OPEN Fig. 2: Connection diagram Terminal Function A1 (A2) LON Bus Router A Side, NET A1 (NET A2) SHA (SHB) Shield Connection for LON Bus Router A Side (B Side) RA1 (RA2) LON Bus Router A Side, Ring NET RA1 (Ring NET RA2) B1 (B2) LON Bus Router B Side, NET B1 (NET B2) Va Vb Power Supply 24V Connection A (+24V at DC) Power Supply 24V Connection B (Ground at DC) L, N Power Supply 230V AC Table 1: Terminal assignment RTR, Ring Topology, Power Supply Terminal Function LON Bus Router A Side, NET A2 (B Side, NET B2) 2 LON Bus Router A Side, NET A1 (B Side, NET B1)

6 3.8 Not Assigned Table 2: Terminal assignment Diagnostics DIAG NET A (B) - RJ45 Caution: Installation by qualified personnel only. Observe established engineering procedures and SysMik published data. Be careful when connecting power! Note: As shown in Fig.2 please make sure that NET A1 is connected to RING RA1), when using the Diagnostics function (RTRSD) (similiary NET A2 applies to RA2). Please see device description for details!

7 Operation Elements The topside of the router includes 1 (RTRS) or 3 (RTRSD) push buttons, named Service Diag. (Service Diagnostics), TEST and Service Router. The respective use is shown in the following tables. Service Router Push shortly Push during setting of supply voltage 1) Description Send service message from router A side /B side Router recovery (RTRSD only) Table 3:Functions of pushbutton Service Router Service Diagnostics Push shortly Push four seconds Push during setting of supply voltage 2) Description (RTRSD only) Send service message from the diagnostics node, termination of a running test Save Domain Tables of the Router Restore manufacturer configuration Table 4: Functions of pushbutton Service Diag. 1) While setting the power supply this button has to be maintained pushed until the test LED lights up. 2) While setting the power supply this button has to be maintained pushed until the test and PWR LEDs light up. Test Push shortly Push four seconds Description (RTRSD only) Immediate start of a test run Direct configuration of the diagnostics node (see device description for detailed information) aborts after six seconds without activation of a push button. The termination is displayed by the diagnostics LED going out and the node returns into normal operation mode. Table 5: Functions of pushbutton TEST

8 More detailed information is provided in the Device Description. For correct bus termination built-in terminators are used, which can be configured by easily accessible DIP switches. Termination for each network segment depends on the used network topology. Especially when using several modules with internal termination, make sure that the network is not inadvertently terminated multiple times. Please observe the guidelines concerning the cable length and suggested cable types, published by Echelon Corporation and the LONMARK Interoperability Association (see and The router termination is made via DIP switches: 1 and 2 switch the router s A side, 3 and 4 the B side (Table 6). Switch Position Termination Topology RTRS[D]-TP/FT10-TP/FT10 NET A (B), NET A (B), 105 Ohm no termination (external termination) Double terminated line topology NET A (B), 52,3 Ohm Single terminated free topology RTRS[D]-TP/FT10-TP/XF1250 (B Side) NET B, Terminator Network Double terminated line topology at TP/XF1250 on side B Table 6: DIP switch positions for bus termination Note: Ring topologies, as free topologies, have to be singly terminated. In order to ensure correct termination during all test phases while using the ring test (RTRSD), the router internal bus termination has to be used.

9 Display Elements Four (RTRS) or nine (RTRSD) LEDs are located on the router s topside. LED Status Description RTRS and RTRSD Service Router SR-A (SR-B) PKT PWR RTRSD only Service Diag. SD Flashing Yellow Green Pulses Green Flashing (0,5s on) Flashing Yellow RTR-A(B) side with running application RTR-A(B) side not configured RTR-A(B) side without application Router is transmitting packets. The longer the green phase the more packets are transmitted. Device is switched-on, Link Power OK Device is switched-on, Link Power error Diagnostics node with running application Diagnostics node not configured Diagnostics node without application COM CRC LON channel utilization < 30% Flashing (0,1..0,9s on) LON channel utilization >= 30 % and <= 70%, Red LON channel utilization > 70% CRC errors < 1% Flashing (0,1..0,9s on) CRC errors >= 1 % and <= 10%, Red CRC errors > 10% Flashing (0,1s an) Test: error free Test: external nodes missing RING Flashing (0,5s an) Flashing (0,9s an) Test: error without exact allocation Test: ring nodes missing Test Red Green Ring rupture detected Test not running Test run active Table 7: LED Status in Normal Mode During configuration mode of a SmartRouter with diagnostic node the

10 significance of the LED s is modified (see Device Description). CompWell Note: If time indications are made for flashing LEDs during on-status the following offstatus represents the time remaining until expiry of the next full second (e.g. 0,1s on followed by 0,9s off).

11 Dimensions and Fitting Installation position: any The device is designed for easy snap-in on mounting rails according to DIN and DIN EN [4.13] 5 [0.2] 43 [1.69] 86 [3.39] 46 [1.81] 60 [2.36] 29 [1.14] 49 [1.93] 58 [2.28] F ig. 3: Dimensions; all measures in mm (inch) Note: If the device has been stored at temperatures below 0 C, please store it under operating temperature for approx. 12 hours for warm up. After storage at temperatures higher than 70 C the device has do be cooled down prior to be switched-on.

12 Technical Data General electrical data RTRS[D] 24V RTRS[D] 230V 1) Supply voltage 24V AC/DC 230V AC Absolute limits 15 35V DC / 18 28,8V AC V AC Power consumption < 1W / < 2 VA < 3VA 1) The 230V variants are equipped in addition with 24V AC/DC supply voltage. By using them the absolute limit values of the 24V variants apply. Housing Type 6TE mounting rail housing acc. to DIN EN Length x width x height [mm] 105 x 86 x 58 Material Weight 24V 230V polycarbonate, polypropylene approx. 200g approx. 310g Environmental Conditions Operating temperature C ( F ) Storage temperature C ( F) Relative humidity 0..75% (non condensing) Degree of protection IP 20 Transceiver Types Seite A Seite B optional TP/FT10, Link Power compatible TP/FT10, Link Power compatible or TP/XF-1250 Table 8: Techncal Data

13 Order Information Device Article Number Devices with Bus Diagnostics function RTRSD-TP/FT10-TP/XF V RTRSD-TP/FT10-TP/FT10 230V IR IR Devices without Bus Diagnostics function RTRS-TP/FT10-TP/XF V RTRS-TP/FT10-TP/XF V RTRS-TP/FT10-TP/FT10 230V RTRS-TP/FT10-TP/FT10 24V IR IR IR IR Table 9: Order information ALTO and IPOCS are trademarks of SysMik GmbH Dresden. Networking Together! is subject to copyright by SysMik GmbH Dresden. Echelon, LON, LONWORKS, LonBuilder, NodeBuilder, LonManager, LonTalk, LonUsers, LonPoint, Neuron, 3120, 3150, Digital Home, LONMARK the Echelon logo, the LONMARK logo and the LonUsers logo are trademarks of Echelon Corporation, registered in the US and other countries. LonLink, LonResponse, LonSupport, LONews, LonMaker and i.lon are trademarks of Echelon Corporation. All other trademarks referred to in this documentation are registered property of the respective owners. Those and further trademarks are used in the text but not specially marked in order not to affect the legibility in the following. Duplication or circulation of this documents as well as utilization and notification of the content are subject to approval by SysMik. Copyright 2003 by SysMik GmbH Dresden

PC - Program to Configure the Diagnostics Node of SmartRouter RTRSD and SmartRepeater RPTSD Software Description

PC - Program to Configure the Diagnostics Node of SmartRouter RTRSD and SmartRepeater RPTSD Software Description ALTOdiagnostics CompWell PC - Program to Configure the Diagnostics Node of SmartRouter RTRSD and SmartRepeater RPTSD Software Description These instructions will support you during installation and use

More information

LonManager PCC-10 and ISA Protocol Analyzers Models 33100-00 and 33100-10

LonManager PCC-10 and ISA Protocol Analyzers Models 33100-00 and 33100-10 LonManager and Protocol Analyzers Models 33100-00 and 33100-10 Description The LonManager Protocol Analyzer provides LONWORKS manufacturers, system integrators, and end-users with a rich set of Windows

More information

GadgetGatewayIa Configurable LON to IP Router and/or Remote Packet Monitor. ANSI 709.1 (LonTalk ) and ANSI 852 (IP) standards based.

GadgetGatewayIa Configurable LON to IP Router and/or Remote Packet Monitor. ANSI 709.1 (LonTalk ) and ANSI 852 (IP) standards based. Configurable LON to IP Router and/or Remote Packet Monitor. ANSI.1 (LonTalk ) and ANSI 852 (IP) standards based. Creator of GadgetTek Products 2966 Fort Hill Road Eagle Mountain, Utah 84043-4108 USA (voice)

More information

HARTING econ 3000 Introduction and features

HARTING econ 3000 Introduction and features HARTING Introduction and features HARTING es, unmanaged, for installation in control cabinets General Description Features The Fast es of the product family HARTING are suitable for industrial applications

More information

Technical Description U00980 Revision 2

Technical Description U00980 Revision 2 Technical Description U00980 Revision 2 TLON Author: Mikael Rivarola Date of issue: 2000-01-07 Date of rev: 2009-01-30 Table of contents 1 Introduction 2 2 Definitions / Explanations 3 3 General description

More information

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB Product Manual ABB i-bus KNX IP Interface IPS/S 2.1 Intelligent Installation Systems ABB This manual describes the function of the IP Interface IPS/S 2.1 with the application program IP Interface. Subject

More information

078-0018-01E. LONWORKS Router User s Guide

078-0018-01E. LONWORKS Router User s Guide 078-0018-01E LONWORKS Router User s Guide Echelon, LonMaker, LONMARK, LonTalk, LONWORKS, Neuron, NodeBuilder, 3120, 3150, and the Echelon logo are trademarks of Echelon Corporation registered in the United

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet NV24A--RE Communicative globe valve actuator for 2-way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Nominal stroke

More information

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000. NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24

More information

Introduction to the LONWORKS System

Introduction to the LONWORKS System Introduction to the LONWORKS System Version 1.0 C o r p o r a t i o n 078-0183-01A Echelon, LON, LONWORKS, LonPoint, LonTalk, Neuron, LONMARK, 3120, 3150, the LonUsers logo, the Echelon logo, and the LONMARK

More information

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053. PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection

More information

ORION TELECOM NETWORKS INC. T1

ORION TELECOM NETWORKS INC. T1 RION TELECOM NETWORKS ORION TELECOM NETWORKS INC. T1 Protection (Fail-Over) Switch Product Brochure & Data Sheet Headquarters: Phoenix, Arizona Orion Telecom Networks Inc. 20100, N 51st Ave, Suite B240,

More information

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese.

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese. Page 1 of 6 Application Proportional 0-10V or 3-position modulating or On/ Off control of Frese OPTIMA Compact valves in heating, ventilating and air conditioning systems. The actuator can be mounted on

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

Product Catalog 2003-2004. www.echelon.com

Product Catalog 2003-2004. www.echelon.com Product Catalog 2003-2004 www.echelon.com Product Catalog 2003-2004 Edition Version A LONWORKS For detailed information on Echelon s products, including the most up-to-date data sheets for the products

More information

PHOENIX CONTACT - 2012-12-14. Features

PHOENIX CONTACT - 2012-12-14. Features Electronic monitoring relay for phase sequence, phase failure, and asymmetry monitoring Data sheet 101748_en_03 1 Description PHOEIX COTACT - 2012-12-14 Features Increasingly higher demands are being placed

More information

InlineControlServer ICS Manual

InlineControlServer ICS Manual InlineControlServer ICS Manual Revision 17 Liability/Imprint This manual is intended to provide support for installation and usage of the device. The information is believed to be accurate and reliable.

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

HARTING mcon 3000 Introduction and features

HARTING mcon 3000 Introduction and features Introduction and features HARTING mcon 3000 es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features The fully managed es of the product family HARTING mcon

More information

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions Facility Pilot Server Art. No. : FAPV-SERVER-REG Facility Pilot Server Art. No. : FAPVSERVERREGGB Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically

More information

IP-852 Channel User s Guide

IP-852 Channel User s Guide IP-852 Channel User s Guide @ 078-0312-01A Echelon, LONWORKS, LonTalk, and the Echelon logo are trademarks of Echelon Corporation registered in the United States and other countries. LonMaker, LNS, and

More information

ZC-24DO CANopen I/O Module: 24 Digital Outputs

ZC-24DO CANopen I/O Module: 24 Digital Outputs Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches

More information

LONWORKS Protocol Analyzer User s Guide

LONWORKS Protocol Analyzer User s Guide LONWORKS Protocol Analyzer User s Guide Revision 1.0 @ E C H E L O N C o r p o r a t i o n 078-0121-01B Echelon, LON, LonTalk, LonBuilder, Neuron, LonManager, LONWORKS, and 3150 are registered trademarks

More information

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version 2.1.0 (2013-11-15)

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version 2.1.0 (2013-11-15) PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN User Manual Document version 2.1.0 (2013-11-15) Products taken into account Product Name Model Part number PCAN-B10011S IPEH-002041 CANopen

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

078-0305-01B. LonScanner FX Protocol Analyzer User s Guide

078-0305-01B. LonScanner FX Protocol Analyzer User s Guide 078-0305-01B LonScanner FX Protocol Analyzer User s Guide Echelon, i.lon, LNS, LonMaker, LONMARK, LonTalk, LONWORKS, Neuron, NodeBuilder, and the Echelon logo are trademarks of Echelon Corporation registered

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

Network Interface Panel User s Guide NPD4747-01 EN

Network Interface Panel User s Guide NPD4747-01 EN User s Guide NPD4747-01 EN Contents Contents Copyright and Trademarks Safety Instructions Important Safety Instructions... 4 Cautions and Notes... 4 Getting to Know Your Network Interface Panel Package

More information

L5354 ControlNet Communications Interface

L5354 ControlNet Communications Interface L5354 ControlNet Communications Interface Technical Manual HA470733 Issue 2 Copyright SSD Drives Inc 2005 All rights strictly reserved. No part of this document may be stored in a retrieval system, or

More information

Waveguide Access Point WGA631. Product Guide

Waveguide Access Point WGA631. Product Guide Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................

More information

is then retained absolutely without interruption.

is then retained absolutely without interruption. Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection

More information

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable Designed for use with the COMbricks SALT repeater All baudrates Redundant

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

WPA-LON Series WPA-LON-1. Application. Model Chart WPA-LON-2 WPA-LON-3. Adapter Card Software

WPA-LON Series WPA-LON-1. Application. Model Chart WPA-LON-2 WPA-LON-3. Adapter Card Software WPA-LON Series TAC I/A Series WorkPlace Communication Adapter Installation Instructions Application The WPA-LON Series WorkPlace Communication Adapters are Echelon LONTALK PC adapter cards. A TAC I/A Series

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Ha-VIS FTS 3000 Introduction and features

Ha-VIS FTS 3000 Introduction and features Ha-VIS Introduction and features Ethernet Switch Ha-VIS FTS 3100s-A 10-port Ethernet Switch with Fast Track Technology configurable via USB General Description Features The Fast Ethernet Switches of the

More information

Smile 11 AS-i Emergency stop with safe AS-i input node

Smile 11 AS-i Emergency stop with safe AS-i input node Original instructions Smile 11 AS-i Emergency stop with safe AS-i input node SAFETY AT WORK ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand

More information

Provides one channel for Ethernet over existing

Provides one channel for Ethernet over existing LB304A LBPS301A LBPS304A Hardened Ethernet Extender Quick Start Guide Provides one channel for Ethernet over existing voice-grade copper twisted-pair wire. copper BLACK wire. BOX Customer Support Information

More information

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output. Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling

More information

MINI MCR-SL-R-UI(-SP)

MINI MCR-SL-R-UI(-SP) Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

IntesisBox KNX - LON

IntesisBox KNX - LON IntesisBox KNX - Gateway for integration of devices into KNX systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi Heavy Industries, Toshiba, Fujitsu,

More information

EIB/KNX IP Interface with Power over Ethernet (PoE)

EIB/KNX IP Interface with Power over Ethernet (PoE) EIB/KNX IP Interface with Power over Ethernet (PoE) IP Interface between LAN and EIB/KNX bus (Quelle: EIBMARKT GmbH, Reference No.: N000401) Page 1 Application area The KNXnet/IP-Interface is used to connect

More information

Hardware Manual CAN-IB130/PCIe CAN-IB230/PCIe PCIe/104 CAN Interface

Hardware Manual CAN-IB130/PCIe CAN-IB230/PCIe PCIe/104 CAN Interface Hardware Manual CAN-IB130/PCIe CAN-IB230/PCIe PCIe/104 CAN Interface The expert for industrial and automotive communication IXXAT Headquarter US Sales Office IXXAT Automation GmbH IXXAT Inc. Leibnizstr.

More information

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server High availability for lower expertise

More information

Provides one channel for Ethernet over existing

Provides one channel for Ethernet over existing LB304A LBPS301A LBPS304A Hardened Ethernet Extender Quick Start Guide Provides one channel for Ethernet over existing voice-grade copper twisted-pair wire. copper BLACK wire. BOX Customer Support Information

More information

R60 USB to CAN interface Manual (1.5 EN)

R60 USB to CAN interface Manual (1.5 EN) R60 USB to CAN interface Manual (1.5 EN) General information R60 USB to CAN interface Manual Version 1.5 EN, 02/2010, DOC01586 Copyright 2010 by ; all rights reserved. Eugen-Adolff-Strasse 134, D-71522

More information

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5 - TFT - 96 MB Product datasheet Characteristics HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB Main Range of product Product or component type Display colour Display size Supply Magelis

More information

HARTING mcon 1000 Introduction and features

HARTING mcon 1000 Introduction and features Introduction and features HARTING mcon 1000 es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features Supporting Ethernet (10 Mbit/s), Fast Ethernet (100 Mbit/s)

More information

mecotron Safety relay ESTOP-2 For emergency stop monitoring

mecotron Safety relay ESTOP-2 For emergency stop monitoring E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated

More information

Danfoss Link Mobile Phone Butler

Danfoss Link Mobile Phone Butler MAKIG MODER LIVIG POSSIBLE Installation Guide www.heating.danfoss.com Table of Contents 1 Introduction... 3 2 Installation... 3 3 Interfaces... 4 4 Wiring... 4 5 SMS Commands... 5 6 Technical Specifications...

More information

Industrial Networks & Databases

Industrial Networks & Databases Industrial Networks & Databases LONWORKS KNX 1 HVAC and BEMS HVAC - Heating, Ventilation & Air Conditioning BEMS - Building & Energy Management Systems 2 3 4 LONWORKS (Local Operating Networks) Open solution

More information

Introduction to the LonWorks Platform. revision 2

Introduction to the LonWorks Platform. revision 2 Introduction to the LonWorks Platform revision 2 0 7 8-0 1 8 3-0 1 B Echelon, LON, LonWorks, LonMark, NodeBuilder,, LonTalk, Neuron, 3120, 3150, LNS, i.lon,, ShortStack, LonMaker, the Echelon logo, and

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

Inwall 4 Input / 4 Output Module

Inwall 4 Input / 4 Output Module Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...

More information

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master

More information

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11 Communication Unit 560CMD11 The SLC works as master for the RTU560 serial peripheral bus (I/O-Interface/ Wired-OR-Bus ). The MPU is responsible for the other tasks. The MPU handles the absolute time and

More information

DALI RC BASIC SO. Control unit Operating instructions

DALI RC BASIC SO. Control unit Operating instructions DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness

More information

TAC Xenta. TAC Xenta 511 and 911 Handbook

TAC Xenta. TAC Xenta 511 and 911 Handbook TAC Xenta TAC Xenta 511 and 911 Handbook TAC Xenta TAC Xenta 511 and 911 Handbook Copyright 2003 TAC AB. All rights reserved. This document, as well as the product it refers to, is only intended for licensed

More information

DMX2PWM 9 Channel Dimmer Setup Manual

DMX2PWM 9 Channel Dimmer Setup Manual DMX2PWM 9 Channel Dimmer Setup Manual www.ecue.de DMX2PWM 9ch Dimmer - Setup Manual e:cue control GmbH An OSRAM Company Rev. 1.3_01/2010 DMX2PWM 9ch Dimmer - Setup Manual Table of Contents 1. Device Overview....................................4

More information

IntesisBox ASCII Server - LON

IntesisBox ASCII Server - LON IntesisBox ASCII Server - LON Gateway for integration of LON devices into ASCII enabled control systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.

More information

HCR3.2/.. Chipcard reader HOTEL SOLUTION

HCR3.2/.. Chipcard reader HOTEL SOLUTION s 6 332 HOTEL SOLUTION Chipcard reader HCR3.2/.. Chipcard reader for hotel room access control Reads access code on chipcard Transfers access code to room controller Built-in optical display of messages

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male

More information

PCAN-USB CAN Interface for USB. User Manual. Document version 2.3.2 (2015-09-03)

PCAN-USB CAN Interface for USB. User Manual. Document version 2.3.2 (2015-09-03) PCAN-USB CAN Interface for USB User Manual Document version 2.3.2 (2015-09-03) Products taken into account Product Name Model Part Number PCAN-USB IPEH-002021 PCAN-USB opto-decoupled Galvanic isolation

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP EtherNet/IP, Modbus TCP, or PROFINET slave Integrated Ethernet switch Supports 10 Mbps/100 Mbps 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection 7/8" males, 5-pin, for power supply Separated power

More information

Universal Gateway. Manual. UGW//maxi UGW//compact UGW//micro UGW//nano25

Universal Gateway. Manual. UGW//maxi UGW//compact UGW//micro UGW//nano25 Universal Gateway Manual UGW//maxi UGW//compact UGW//micro UGW//nano25 Version 1.0 18.06.2014 Content 1. Preface... 5 2. Bibliography... 6 2.1. Interesting links on BACnet in the World Wide Web... 7 2.2.

More information

KNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems

KNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems KNX Gateway Light-Control R User manual-ver.1 LC-IPGW-001 Intelligent Installation Systems Contents 1. Summary ---------------------------------------------------------------------------------------------------------------------

More information

Mini Amp Gizmo. User s Manual. RJM Music Technology, Inc.

Mini Amp Gizmo. User s Manual. RJM Music Technology, Inc. Mini Amp Gizmo User s Manual RJM Music Technology, Inc. Mini Amp Gizmo User s Manual Version 1.1 March 15, 2012 RJM Music Technology, Inc. 2525 Pioneer Ave #1 Vista, CA 92081 E-mail: support@rjmmusic.com

More information

Easylon For Automation with LonWorks Interfaces Connecting to LonWorks Software LonWorks Data Access Network Components From Repeater to Terminator

Easylon For Automation with LonWorks Interfaces Connecting to LonWorks Software LonWorks Data Access Network Components From Repeater to Terminator Easylon For Automation with LonWorks Interfaces Connecting to LonWorks Software LonWorks Data Access Network Components From Repeater to Terminator Contents 1 Contents Easylon Interfaces 4 Overview 7

More information

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS Safety precautions Safety precautions The DSL modem alpha DSL WTM HS complies with the European norm EN60950 safety of information technology

More information

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves

More information

HARTING econ 4000 Introduction and features

HARTING econ 4000 Introduction and features HARTING econ 4000 Introduction and features HARTING econ 4000 es, unmanaged, for flat wall mounting General Description The Fast es of the product family HARTING econ 4000 are recommended for use in the

More information

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com Document updates: Version Data Description V1.0 2015.05.25 Finish new document HVAC Controller User Manual INDEX 1. Overview...1

More information

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1 BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -

More information

CAN@net II Intelligent PC/CAN Interface. Manual

CAN@net II Intelligent PC/CAN Interface. Manual CAN@net II Intelligent PC/CAN Interface Manual IXXAT Automation GmbH Leibnizstr. 15 D-88250 Weingarten Tel.: +49 (0)7 51 / 5 61 46-0 Fax: +49 (0)7 51 / 5 61 46-29 Internet: www.ixxat.de e-mail: info@ixxat.de

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP s 9 270 Desigo PX BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP PXG3.L PXG3.M Routing between BACnet/IP, BACnet/LonTalk (PXG3.L only), and BACnet MS/TP Supports BACnet/IPv4 and BACnet/IPv6 ANSI/ASHRAE

More information

IntesisBox KNX LG Air Conditioning

IntesisBox KNX LG Air Conditioning IntesisBox KNX LG Air Conditioning Gateway for integration of LG Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB) bus. Direct connection to LG outdoor unit

More information

Installation and start-up guide NETA-21 remote monitoring tool

Installation and start-up guide NETA-21 remote monitoring tool Remote monitoring options for ABB drives, converters and inverters Installation and start-up guide NETA-21 remote monitoring tool 3AUA0000096881 REV C Effective: 2013-03-01 2013 ABB Oy. All rights reserved.

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

overview DyNet over RS485

overview DyNet over RS485 technical guide systems integration overview Integration between various control systems within projects, reduce end-users need to have multiple interactions to perform what seems like one task such as

More information

Operating instructions. AS-i Profibus gateway AC1411 / AC1412 7390884/00 04/2014

Operating instructions. AS-i Profibus gateway AC1411 / AC1412 7390884/00 04/2014 Operating instructions AS-i Profibus gateway AC1411 / AC1412 7390884/00 04/2014 Contents 1 Preliminary note 4 1.1 Notes on this document 4 1.2 Symbols used 4 2 Safety instructions 4 2.1 General 4 2.2 Installation

More information

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050 Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage

More information

PCAN-MicroMod Universal I/O Module with CAN Interface. User Manual. Document version 2.1.0 (2014-01-16)

PCAN-MicroMod Universal I/O Module with CAN Interface. User Manual. Document version 2.1.0 (2014-01-16) PCAN-MicroMod Universal I/O Module with CAN Interface User Manual Document version 2.1.0 (2014-01-16) Products taken into account Product Name Part number Model PCAN-MicroMod IPEH-002080 with firmware

More information

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.

More information

ABB i-bus KNX IP Router IPR/S 2.1

ABB i-bus KNX IP Router IPR/S 2.1 Product Manual ABB i-bus KNX IP Router IPR/S 2.1 Intelligent Installation Systems This manual describes the function of the IP Router IPR/S 2.1 with the application program IP Routing. Subject to changes

More information

WEB log. Device connection plans

WEB log. Device connection plans WEB log LIGHT+ 20 BASIC 100 PRO unlimited Device connection plans Version 20151210* Copyright Copyright for this manual remains with the manufacturer. No part of this manual may be reproduced or edited,

More information

SAFETY MANUAL SIL RELAY MODULE

SAFETY MANUAL SIL RELAY MODULE PROCESS AUTOMATION SAFETY MANUAL SIL RELAY MODULE KFD0-RSH-1.4S.PS2 ISO9001 3 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery

More information

Drayton Digistat +2RF/+3RF

Drayton Digistat +2RF/+3RF /+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer

More information

ADM1TE 5/30A DIN rail single phase two wire energy meter

ADM1TE 5/30A DIN rail single phase two wire energy meter ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.

More information

Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3

Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3 Data Sheet Optimux-45, Optimux-45L Up to 28 T1 or 21 E1 channels multiplexed into a single 45 Mbps data stream Any Traffic over Fiber Combination of T1 and E1 channels Transmission over coax or fiber optic

More information

Technical Information

Technical Information Technical Information Interface with DDC 6 720 642 841-00.1RS Logamatic LON-Gateway For heating contractors during project planning 6 720 643 554 (11/2010) US/CA Contents Contents 1 Explanation of symbols

More information

IMR 6000/10../20../30

IMR 6000/10../20../30 IMR 6000/10../20../30 System frame Component of the MMS 6000 Machine Monitoring System Applications: Slots for adaptation of the signal processing periphery (monitors, logic cards and interface cards)

More information

POINTS POSITION INDICATOR PPI4

POINTS POSITION INDICATOR PPI4 POINTS POSITION INDICATOR PPI4 Advanced PPI with Adjustable Brightness & Simplified Wiring Monitors the brief positive operating voltage across points motors when they are switched Lights a corresponding

More information

KNX Gateway RGK02-5023E-01

KNX Gateway RGK02-5023E-01 KNX Gateway RGK02-5023E-01 Table of contents Page 1 General Information 1.1 Technical data 5 1.2. Intended Use 6 1.3 Specifications 6 1.4 Compatibility 6 1.5 Scope of delivery 6 2 Information about the

More information