Measure Monitor Control
|
|
- Michael Bryant
- 8 years ago
- Views:
Transcription
1 WDM INC Uptime Devices
2 What We Do We provide network appliances and other mission critical network infrastructure (both hardware and software solutions) for network management and remote monitoring and control applications. Specific areas of focus by Uptime Devices include environmental, security, and power. In today s mission critical networks many things can affect availability. Software issues, Hardware issues, even things not on the Network leave you vulnerable to costly failures. Uptime Devices completes your protective portfolio by network and web enabling previously unreachable devices, giving you the ability to head problems off before they happen and giving you the freedom to manage your network on your terms. Uptime Devices
3 Clients With the largest installed base in the market here is a sampling of some of our satisfied clients:
4
5
6 sensorarray Product Family sensorarray sensorarray Pro sensorarray XP 8 external ports standard Expandable to 48 ports Desktop 8.5" W x 1.75" H x 4.25"D (215.9mm W x 44.45mm H x mm D) connect up to 6 dry contacts on a port via common ground 14 external ports standard Expandable to 48 ports Desktop, 1U Rack mount or 0U Vertical mount 17" W x 1.75" H x 5" D (431.5mm W x 44.45mm H x 127mm D) 18 port expansion unit for sensorarray and sensorarray Pro Desktop, 1U Rack mount or 0U Vertical mount 17" W x 1.75" H x 5"D (431.5mmWx44.45mm H x 127mm D
7 sensorprobe Features On board graphing capability Sends notifications External sensor port with auto-sense Sends SNMP traps to 2 destinations Supports SNMP polling 2 levels of password protection Internal web server 0 U rack mountable Fully compliant with all operating systems Includes easy to read documentation and helpful utilities Free trial version of OverTime MIB integrates with all popular NMS
8 sensorarray Typical Application Areas Data Centers Hot Spots Critical Equipment Cabinets Server Rooms Wiring Closets Remote Locations Laboratories Warehouses Monitor non-snmp equipment HVAC Power UPS Almost any kind of sensor or switch Uptime Devices
9 sensorarray Typical Application Uptime Devices
10 sensorarray User Features Plug and Go Network Appliance User Friendly Web Interface SNMP Traps Notifications IP Settings Security NNM MIB Quick start installation guides Helpful Utilities Thorough Documentation Package Uptime Devices
11 Environmental Sensors Humidity Water Security Contacts Temperature Airflow Motion Detection In addition to our proprietary line of environmental sensors, we can support a wide variety of sensors you may have or are planning on installing.(teach an old sensor new tricks)
12 External Sensors HUMIDITY SENSORS Description Humidity sensors measure the relative humidity in the air. The sensor is composed of a semiconductor whose capacitance varies with humidity. The small changes in capacitance are converted into a DC voltage by active circuits placed near the sensor. This DC voltage is then transmitted to the sensorarray along a 15 foot cable. The DC voltage is measured by the sensorarray using it A/D converter. WATER DETECTORS Description Water Detectors are active switches that close in the presence of water. The sensorarray senses the closure and reports the condition. Water detectors can be wired in parallel through through use of RJ45 splitters. This way multiple water detectors can use a single port on the sensorarray. There are no reasonable limits on the distance of the water detectors from the sensorarray. SECURITY SENSORS Description Security Sensors come in pairs. They are active switches that close when one half of the sensor is in close proximity to its mate. When the two sensor pairs are moved apart from each other they open. The sensorarray senses the closure and open and reports the condition. Security Sensors can be wired in series so that multiple sensors can use a single port on the sensorarray. There are no reasonable limits on the distance of the security sensors from the sensorarray. Uptime Devices
13 External Sensors TEMPERATURE SENSORS Description Temperature sensors measure the temperature levels in an environment. They have a range of 55 C to 100 C and are accurate to 0.5 C. There are no reasonable limits on the distance of the temperature sensors from the sensorarray. Uptime Devices
14 Switches Monitor 32 Inputs Control 20 Outputs Open/Closed or Ground/+5V Uptime Devices helps some of the biggest companies in the world manage their Air Conditioning and UPS systems
15 External Sensors The sensorarray provides for a large number of external sensor inputs and outputs. The sensorarray has 2 rs232 lines that can be used to read or control external equipment. The sensorarray has 32 general purpose I/O lines that can be used to sense inputs or drive outputs. There are 4 high current output lines that can be used to drive motors or relays. There are 7 Analog to Digital inputs that can sense input voltages INPUT AND OUTPUT SWITCHES Output The general purpose switches can be either input or output. When used as an output it can source 20 ma. You can select the output voltage by setting the OutputLevel to a Low or a High. When set to Low the pin will output 0 volts. When set as a High the pin will output 5 volts. Input When used as an input a switch will retain any error condition until it is read via snmp. Therefore if a switch encounters a critical condition at any time it must report that condition before it can return to a normal state. Uptime Devices
16 Power Voltage Sensor- Detects the presence of AC Voltage (50-250VAC) The sensorarray supports the complete line of Baytech Intelligent Power Devices. These give you the ability to turn equipment on, off, or re-boot remotely as well as measure Current, Maximum Current, Voltage, and True Power
17 External Sensors VOLTAGE SENSORS Description Voltage Sensors are active switches that close when voltage is sensed. When voltage is not present the switch will open. These switches are therefore normally closed. POWER MODULE Description The power control module controls 6 power outlets. There is a power control module available for both the European and American markets. The power control module interfaces to the sensorarray through the RS232 port of the sensorarray. Each outlet of the power control module can be individually controlled through the web based interface or the snmp interface. Each outlet on the power control modules can be set to on, off, and reboot. The reboot command temporarily cycles power to that port. The settings on each outlet of the power control module are retained even if the power control module has its power recycled. Uptime Devices
18 Power Solutions Voltage Detection Voltage Sensor - Detect the presence of AC voltage. 110V/220V. The voltage detector will report the loss of AC to the sensorarray generating an snmp trap to your network monitoring system. It can also generate an notification Power Metering Remote Power Sensor - a dual side power-sensing unit. The input and output for the remote power sensor is 20 Amp 115 VAC. It measures and reports: True RMS Current, TrueRMS Voltage, True Power in VA, Temperature. The remote power sensor will report SNMP traps based on preset conditions for current, voltage, power and temperature. Specifications : Power Input: (2) Non detachablenema L5-20P Power Output: (2)Nema L5-20R power receptacles Interface: RS-232 interface with RJ45 connector Indicators: Power and status indicator LEDs Mounting: Floor mount Dimensions: 8.25"w X 5"d X 2.59"h Uptime Devices
19 Remote Power Control Power Control Modules - Re-boot remotely. Control on, off or reboot to the recipticle level. US Power Receptacles Six 15 Amp 110 V-AC receptacles Circuit Breaker: 125V, 15 Amp UL approved User definable names Call for other US configurations Environment Dimensions Indicators Communications cable Operating range 0 C +70 C Storage range - 40 C +80 C 16.73"w x 5.25"d x 1.72"h, 19" rack or desk mount One green power LED and six red LEDs indicate receptacle on/off status RJ45 jack to sensor using 15 foot UTP Cat 5 wire. Sensor Remote Control on/ off all or individual receptacles via web or SNMP reboot all or individual receptacles via web or SNMP Last settings saved on power loss Yes- will stay in last condition prior to power loss Power-up routine on power loss Yes- The power-up routine to each receptacle left in the on position is performed sequentially to minimize power surges. Sensor power Requires external 110 V-AC 15 Amp power. Maximum number of power control modules per sensorarray one- call if more are needed Uptime Devices
20 Intelligent Power Strips 20 controllable Receptacles plus one always on. True RMS current monitoring with overload alarm buzzer and indicator LED. Individual or collective control of the receptacles. Programmable unit ID and receptacle names. Zero U Vertical-mount Controllable via Network Management System using the sensorarray In the event of a power failure to the unit itself, the 232 PowerStrip retains the most current operational status for each outlet in nonvolatile memory. When the PowerStrip regains power, it restores each outlet to those status settings. For example, if Outlet 1 and Outlet 2 are ON and the remaining outlets are OFF when a power loss occurs, Outlet 1 & 2 will be placed in the ON position automatically when power is restored. The power-up routine to each receptacle is performed sequentially to minimize power surges. During normal operation, the intelligent powerstrip¹s circuit breaker status is "ON". If the circuit breaker status is "OFF," that indicates the circuit breaker has been tripped. General Specifications: Interface 9600 bps, EIA-232, eight-pin RJ45 connector. Environment Operating temperature range is from 0 to 40 degrees Celsius. Storage temperature range is from -40 to 80 degrees Celsius. Humidity tolerance is from 5 to 95 percent RH. Dimensions 1.75"w X 1.75"d X 65.76"h Indicators Green power LED, green receptacle status LED and red trip alarm LED Mounting Vertical aligned on standard rack Warranty One year on parts and labor Power Receptacles Twenty-one NEMA 5-15 receptacles 110V AC (+10%), 50/60 Hz, 20 Amps Circuit Breaker 110V AC 20-Amps Control The 232 PowerStrip is controlled by simple commands of ON, OFF and REBOOT. Access the internal menu through a serial connection through the sensorarray. Power Plug: L5-20P (Twist Lock), Optional 5-20P Uptime Devices
21 Camera We have done many successful installations integrating Axis network camera capabilities to capture and send upon trap conditions. You can view in real-time up to 4 Axis cameras simultaneously, in the Uptime Devices web interface
22 External Sensors CAMERA DETAIL The sensorarray can be integrated with up to 4 Ethernet based cameras from axis corporation. If you have selected the Advanced Sensor Html View from the System View, you will be able to configure these cameras. Customers have integrated the security features of the sensorarray with cameras. For example the sensorarray can be used to send a trap to a host system whenever a security switch is triggered. This trap can then be used to record and timestamp a series of pictures at the time of the incident. When a camera is placed online it will appear on the Summary page of the sensorarray. This will provide the operator with a single html web page from which to view all of the status information. Uptime Devices
23 Software Solutions We provide software solutions for data logging, graphing, and export. We have standalone versions for NT and all versions of Unix. We also have several packages written specifically as plug-ins for HP OpenView.
24 Software Solutions OverTime Solo Measure Monitor Control OverTime Solo OverTime collects SNMP statistics from network devices and prepares HTML pages to graph the results. See all your network statistics OverTime. What does OverTime Solo do? 1. For Input / Output devices like the sensorarray, routers, switches and hubs, OverTime uses SNMP to query the selected devices to see what Input/Output interfaces they have and sets up a Round Robin Database (RRD from Tobias Oetiker, the creator of MRTG and RRDTool). The RRD does not grow in size once setup. OverTime Solo performs its own SNMP data collections. OverTime updates an index HTML page with the new devices. When you want to see the information collected, you simply drill down from the index page and OverTime graphs the collected data. An HTML page showing the most recent and detailed graphs for each interface on the device is displayed, along with IO errors for each interface and CPU utilization on supported devices. All of the graphs on this device page are linked to more detailed views with four graphs being generated that show the information over progressively longer periods. 2. OverTime Solo can collect any numeric SNMP data and follows the same process as above except that the you specify which SNMP data to collect. This flexibility allows OverTime to record and graph such diverse information as Temperature &Humidity from an environmental monitor, Mail Queues from an e- mail system and disk space usage from servers. Labels for titles, legends and y-axis are automatically generated, but are easily modifiable by the user. 3. OverTime is used to display PingTime collected response time information. Monitoring of device by OverTime can be stopped as easily as they were started. OverTime makes the most efficient usage of the host system's resources by performing the least amount of work. SNMP collections are performed in bulk across the network, saving bandwidth. OverTime does not waste system time generating never-to-be-seen graphs. Graphs and HTML pages are only produced on user request. Indeed, if two users are viewing the same page, only one of them will produce new graphs and the other views the graphs already generated. Uptime Devices
25 Uptime Devices Software Solutions Measure Monitor Control PingTime PingTime PingTime uses a Cisco Router to record ping Round Trip Times from the router to any IP address. The minimum, average and maximum response time are recorded over several pings by the router and the results retrieved. What does PingTime do? PingTime works in 2 different ways. 1. PingTime's WEB based diagnostic interface allows the user to enter the IP address of the Cisco Router to act as the test source and one or more IP addresses to be tested. The results of the testing are displayed on the resulting HTML page. This is a very quick and convenient way of testing response times from one remote location to another without having to telnet into the router and then run all the pings. Indeed, the user does not even need access to the router to perform the tests so that even staff who would not normally access the router, could have the ease of this diagnostic tool. 2. PingTime can be used as an additional source for OverTime. The same HTML pages that OverTime produces can also include PingTime results. In this case, PingTime is run regularly and the results recorded into an RRD. This information can then produce a graph like the one here..
26 Software Solutions Measure Monitor Control LineUp Lineup LineUp moves selected symbols on the HP OpenView submap and evenly spreads them either on an axis or a vector joining the extreme symbols. The resulting maps are pleasing to the eye and make laying out maps more attractive and easier to use. How easy is LineUp to use? LineUp is very simple, easy and intuitive to use. Simply select the symbols you would like in a straight line and then click on the View menu and either "Align Symbols on axis" or "Align symbols end-to-end". That¹s all!! "Align symbols on axis" moves two or more selected symbols to their most natural axis. If the selected symbols are spread roughly along a horizontal line, then LineUp moves them to be evenly spread along the average horizontal line that runs through the symbols. If the symbols are spread roughly along a vertical line then it is to this line the symbols are moved. "Align symbols end-to-end" moves three or more selected symbols to be evenly spread along a vector that joins the most extreme symbols Uptime Devices
27 Credentials Certifications by the best: Hewlett-Packard (OpenView) Computer Associates (TNG) IBM (Tivoli) Award Winning Products: Best of Show Sensor Expo 2001
28 General Terms One-year warranty Free Upgrades Free support by and incoming calls 30 day money back guarantee
29 Company Background Uptime Devices history dates back to 1981 when Brad Klein started AKCP providing solutions to major computer companies including DEC, Compaq, and Hewlett-Packard. The sensorarray has been in the field for over 3 years and has enjoyed a successful history of helping major enterprises manage their mission critical network management needs. Lawrence Latham - CEO Has served as President and Chief Executive Officer of successful growth companies in the high technology field including Aera Corporation, a process control and monitoring company for the semiconductor industry. His experience includes mergers and acquisitions and spans from the startup phase to global market leadership. Mr. Latham is active in the community and currently serves on several boards.
30 Company Background Brad Klein CTO Since graduating in the top 5% of his class from the University of Massachusetts, Brad Klein has specialized in software development for operating system internals, communications, and routers for Fortune 500 companies such as Hewlett-Packard, Oracle, Compaq and DEC. Mr. Klein is the inventor of numerous Internet enabled, enterprise level, network equipment devices, including the industry leading sensorarray. The company Mr. Klein created in 1981 is now Uptime Devices.
31 Company Background Laurie Gellatly Laurie Gellatly has over 20 years experience in the computing industry. Technical expertise in various computing languages and network infrastructure including operating systems, LAN and WAN installation and management derived over the years working for international time sharing and investment banking institutions. A certified router specialist with experience in synchronous and asynchronous transmission protocols and the hardware that supports today's modern network infrastructures.
Remote Site Management Solutions
Remote Site Management Solutions Bay Technical Associates 200 N. 2 nd Street Bay St. Louis, MS 39520 800-523-2702 * Fax 228-467-4551 International 228-467-8231 1.0 REMOTE SITE MANAGEMENT (SELLING THE CONCEPT
More informationSMART SENSOR COLLECTION
TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8
More informationComputer Cabinet Environment Monitor
Computer Cabinet Environment Monitor WxGoos-1 (03/30/2006) Individual or Multiple Cabinet Monitoring A simple, low-cost device for monitoring cabinets and racks, the WxGoos-1 contains five built-in environment
More informationsecurityprobe 5E Standard
securityprobe 5E Standard securityprobe 5E Standard Monitor the physical environment and receive alerts of any disturbances, such as unauthorized intruders, security breaches, high temperatures, smoke,
More informationTable of Contents. 1. Introduction...1. 2. PDU Package...2. 3. Function...3. 4. Installation...5. 5. Web Interface...7
PDU User Manual Table of Contents 1. Introduction...1 2. PDU Package...2 3. Function...3 4. Installation...5 5. Web Interface...7 1. Introduction The PDU is an Internet ready device designed and is equipped
More informationsecurityprobe5es -X20
securityprobe5es -X20 v.100.00x securityprobe5es -X20 will monitor the physical environment and alert you of any disturbances, such as unauthorized intruders, security breaches, high temperatures, smoke,
More informationPower Commander Power Distribution Units from Wiremold/Legrand offer
Power Commander Power Distribution Units Rack Power Distribution Solutions for IT/Network Environments Power Commander Power Distribution Units from Wiremold/Legrand offer comprehensive power distribution
More informationRack Power Distribution
The Rack PDU Selector is located at: www.apc.com/tools/selector/pdu Test drive a metered or switched Rack Power Distribution Rack PDU at testdrive.apc.com 132 Fairgrounds Road West Kingston, RI 02892 Phone:
More informationCompatible with all of the Ravica range of Intelligent Sensors it provides a complete environmental, access control and security monitoring solution.
Sensor Control... Control... Sensor Control... Access securityprobe 5E Standard securityprobe 5E Standard Monitor the physical environment and receive alerts of any disturbances, such as unauthorized intruders,
More informationServSensor. March 2004 EME102A, EME103A, EME104A EME108A, EME109A, EME110A EME111A-xx, EME112A-xx, EME113A-xx
March 2004 EME102A, EME103A, EME104A EME108A, EME109A, EME110A EME111A-xx, EME112A-xx, EME113A-xx Rev. 1.1 CE STATEMENT This product carries the CE mark to indicate compliance with the European Directive
More informationLight Level. Sensor. Accessory Device Connector. Serial Connector. Lamps. Temperature and Air Flow. Humidity. Sensor I/O Ports (terminals) Sensor
WeatherDuck: Serial Port Climate Monitor WxDux-1 Specification (5/4/03). IT WatchDogs, Inc. Remote PC Environment Monitor A simple, low-cost way to monitor remote computer rooms or cabinets, the WeatherDuck
More informationNetwork Power Manager. User Manual
Network Power Manager User Manual Table of Contents 1. Introduction... 1 2. PDU Package... 2 3. Function... 3 4. Installation... 4 5. Web Interface... 5 1. Introduction The PDU is an Internet ready device
More informationInterface Adapters PS/2 Interface Adapter 1 pack 262588-B21 PS/2 Interface Adapter 8 pack 262587-B21 USB Interface Adapter 1 pack 336047-B21
Overview Models HP Server Console Switches 1X8-Port KVM 336044-B21 2X16-Port KVM 336045-B21 CAT5e Cables 3 Foot (1 m) 4 pack 263474-B21 6 Foot (2 m) 8 pack 263474-B22 12 Foot (4 m) 8 pack 263474-B23 20
More information8 Intelligent PDUs. Intelligent Power Distribution Units for Data Centers
BRC_PDU_US_B_BRC_IcePack 4/30/13 11:31 AM Page 2 8 Intelligent PDUs Intelligent Power Distribution Units for Data Centers Intelligent Power Distribution Units Siemon s line of intelligent PDUs provide
More informationPacket Power. Data Center Solutions. Packet Power for Data Centers. Benefits. Features. The Packet Power Solution. Data Center Monitoring Made Easy
Data Center Solutions Packet Power for Data Centers Packet Power provides the easiest, most cost-effective way to capture detailed power and temperature information for both single-site and large multi-facility
More informationRemote Monitoring Unit SC8100. Monitoring Unit SC8100
Monitoring Unit SC8100 Remote Monitoring Unit SC8100 Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more. Compatible with all
More informationProduct Guide CM-Relay
Product Guide CM-Relay www.theclimate.co.uk tel: 01491 410913 The Climate, Badgers Bank, Harpsden, Henley-on-Thames, Oxfordshire RG9 4HL. Overview CM-Relay combines climate monitoring with remote relay
More informationJNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
More informationUninterruptible Power Supply
96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features
More informationThe complete environmental monitoring system for your data center.
2007. All rights reserved. Black Box Corporation. FREE 24-hour Tech Support: 724-746-5500 blackbox.com AlertWerks The complete environmental monitoring system for your data center. FEATURES This fully
More informationQuickSpecs. Models HP Server Console Switches
Overview are key components for rack mount implementations (a console represents one keyboard, video monitor, and mouse (KVM) attached to a server). The family of allows multiple servers in a rack to be
More informationQuickSpecs. HP IP Console Switch with Virtual Media Overview
Overview HP's IP Console Switch with Virtual Media is a key component in managing the heterogeneous data center and along with the IP Viewer software allows remote access to multiple servers running various
More informationModel #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V
SmartPro VS Tower UPS System Intelligent, line-interactive power management system Model #: SMART2200VS 2200VA / 2.2kVA line interactive tower UPS Maintains 120V nominal output over an input range of 79
More informationA Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing.
Appro HyperBlade A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing. Appro HyperBlade clusters are flexible, modular scalable offering a high-density
More informationSmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications
SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications Model #: SU3000RTXL3U 3000VA online 3U rack / tower UPS Enhanced serial communications
More informationInnovative Electronics for a Changing World INDEX
Innovative Electronics for a Changing World INDEX 1. SYSTEM DESCRIPTION 2. BOARD CONNECTIONS terminals and indicators 3. CONNECTION DIAGRAM 4. START UP GUIDE and passwords 5. HOME PAGE 6. STATUS PAGE 7.
More informationTable of Contents. Chapter1. Introduction...1. 1.1 Before Installation... 1 1.2 System Requirements... 1
Table of Contents Chapter1. Introduction...1 1.1 Before Installation... 1 1.2 System Requirements... 1 Chapter2. IVS-110 1-Channel Internet Video Server...2 2.1 Package Content... 2 2.2 Physical Installation...
More informationTereScope Management Options
Introduction TereScope Management Options MRV Communications, Inc. offers a variety of management options for the TereScope FSO product family. Whether you are a Network Service Provider, Cellular Network
More informationED1259R5 Updated April 2011 For latest specs visit www.legrand.us/wiremold
Rack Power Distribution Solutions for IT/Network Environments Wiremold Power Commander Power Distribution Units offer comprehensive power distribution solutions for IT environments from networking solutions
More informationIndustrial-Grade UPS System Heavy-duty power protection for harsh industrial environments
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch
More informationIntroducing Tripp Lite s PowerAlert Network Management Software
Introducing Tripp Lite s PowerAlert Network Management Software What Can It Do For You? Improve the accuracy and efficiency of the network operations staff in the context of power and environmental management
More informationPN5212/PN5320/PN7212/PN7320
PN522/PN5/PN722/PN7 Over the NET Distribution Units ALTUSEN Over the NET products are Distribution Units that offer outlet level control combined with remote access to give IT administrators the ability
More informationSNMP Web Management. User s Manual For SNMP Web Card/Box
SNMP Web Management User s Manual For SNMP Web Card/Box Management Software for Off-Grid Inverter Version: 1.2 Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Overlook...
More informationTrueAlarm Fire Alarm Systems
TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es
More informationTemperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
More informationModel #: SMART2200CRMXL
Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: saleshelp@tripplite.com Model #: SMART2200CRMXL SmartPro Compact Rackmount UPS System - Precision Protection for
More informationRack Power Distribution. Worldwide
Rack Distribution Worldwide Introduction APC TM by Schneider Electric TM offers a wide array of standardized Rack Distribution Units (PDUs) designed to increase manageability and efficiency in your data
More informationPacket Power. Data Center Solutions. Packet Power. Packet Power for Data Centers. Benefits. Features. The Packet Power Solution
Data Center Solutions for Data Centers provides the easiest, most cost-effective way to capture detailed power and temperature information for both single-site and large multi-facility operations. Gain
More informationNMS300 Network Management System
NMS300 Network Management System User Manual June 2013 202-11289-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for purchasing this NETGEAR product. After installing your device, locate
More informationENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000
ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000 I. General A. Summary The monitoring system shall be an expandable, self-contained microprocessor-controlled IMS-4000 Host unit (hereafter referred to as
More informationSNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems
SNMP Web card User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 3 1.1 Introduction... 3 1.2 Features... 3 1.3 Overlook... 3 1.4 Installation and
More informationDataSMART 554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8. T1/FT1 Single-port Plug-in DSU/CSUs
554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8 = PDF Leased Line Economical T1 Internet Access Central Site T1 Management T1/FT1 Single-port Plug-in DSU/CSUs Key Features Specifications Ordering Information
More informationNetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2
NetProbe Lite Web Based 8 Channel Sensor Collector User Manual Version 1.2 Copyright Information Copyright 2004-2005, Mega System Technologies, Inc. All rights reserved. Reproduction without permission
More informationHow to Maximize Data Center Efficiencies with Rack Level Power Distribution and Monitoring
How to Maximize Data Center Efficiencies with Rack Level Power Distribution and Monitoring Brian Rehnke e-pdu Business Development Manager November, 2011 The Problems Energy Usage in most data centers
More informationPE8216/PE8324. Energy Intelligence Solutions
PE8216/PE8324 As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (eco PDUs) to effectively increase the efficiency of data center power usage. The
More informationsecurityprobe-x20 SNMP-based Environmental and Security Monitoring Solution
WE SENSE DISASTER... AND NOW YOU ARE IN CONTROL... I securityprobe-x20 SNMP-based Environmental and Security Monitoring Solution Applications Monitoring Solutions for : Data Center & Server Rooms Telecommunication
More informationPE6108/PE6208/PE8108/PE8208
Energy Intelligence Solutions PE6108/PE6208/PE8108/PE8208 eco PDU Distribution Unit ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency
More informationApplication Note: Monitoring Branch Circuit Loads in Critical Facilities
Application Note: Monitoring Branch Circuit Loads in Critical Facilities Description of application: The AcquiSuite data acquisition server (DAS) from Obvius is used to monitor the electrical loads and
More informationPanduit Infrastructure Management Software for Data Centers and Enterprises
Panduit Infrastructure Management Software for Data Centers and Enterprises SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers SmartZone Rack Energy Kits Features: Simple
More informationSMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision 090210 [Version 2.2]
SMS Alarm Messenger SMSPro_Setup Revision 090210 [Version 2.2] ~ 1 ~ Contents 1. How to setup SMS Alarm Messenger?... 3 2. Install the SMSPro_Setup software... 5 3. Connection Type... 6 4. Connection Port
More informationSOLARCARE SERIES PRODUCT AND APPLICATION GUIDE
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy
More informationSOHOware Long Reach Ethernet (LRE) Solution
Application Note - LRE SOHOware Long Reach Ethernet (LRE) Solution LRE Technology Benefits SOHOware solution is based on Very high bit-rate DSL (VDSL) robust technology Solution supports transfer rates
More informationEthernet. Customer Provided Equipment Configuring the Ethernet port.
Installing the RDSP-3000A-NIST Master Clock. Ethernet Connect the RJ-45 connector to a TCP/IP network. Equipment The following equipment comes with the clock system: RDSP-3000A-NIST Master Clock Module.
More informationSiteRanger tm. Power quality / site monitoring. Comm/net Systems, Inc.
SiteRanger tm Comprehensive Broadband/ Enterprise site monitoring device for Headend s, Hub Sites. Power quality / site monitoring Focus on power system infrastructure Retrofit legacy devices for remote
More informationSECTION 16911 WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM
WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM PART 1 GENERAL 01 02 03 04 SCOPE This section describes the metering, communications, and visualization requirements for a modular, scalable Web-based Power
More informationHP Server Console Switch with Virtual Media Overview
Overview HP's Server Console Switch with Virtual Media is a key component in managing the data center. Connections for two local consoles (a console represents one keyboard, monitor and mouse) allow access
More informationProduct Description. Model VM 500 series [ VM508/VM508E ] Water Alarm. Telephone/Pager Alert Calls. Power Alarm. Maximum Number of Sensors
Product Description You need to protect the equipment in your data center, computer room, or equipment room from the damaging effects of high temperature and high humidity. The best way to protect sensitive
More informationEaton epdu. Intelligent and flexible power distribution
Eaton epdu Intelligent and flexible power distribution Introduction and overview With today s changing technology, increasing power demands and the need for reliability, data centre professionals require
More informationENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION
ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is
More informationEthernet Adapter Owner's Manual
Corinex Intelligent PowerNet Corinex Intelligent PowerNet Ethernet Adapter Owner's Manual This Owner s Manual, as well as the software described in it, is furnished under license and may be used or copied
More informationROOM GUARD VT300. Environmental Infrastructure monitoring
Environmental Infrastructure monitoring ROOM GUARD VT300 Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more. Compatible with
More informationNAFEM Gateway User s Manual For Watlow part numbers NGW0-0000-0000, NGW0-0000-2400, NGWC-0000-0000, NGWC-0000-2400
NAFEM Gateway User s Manual For Watlow part numbers NGW0-0000-0000, NGW0-0000-2400, NGWC-0000-0000, NGWC-0000-2400 1241 Bundy Boulevard, P.O. Box 5580, Winona, Minnesota USA 55987-5580 Phone: +1 (507)
More informationOverview of the Cisco 2500 Series Access Server
CHAPTER 1 Overview of the Cisco 2500 Series Access Server The Cisco 2500 series access server is a full-featured communication server with multiprotocol routing capability between synchronous serial, LAN,
More informationNetwork Management Card. User Manual
User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1
More informationManual. IP Sensor and Watchdog IPSW2210. I P S W 2 2 1 0 M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.
IP Sensor and Watchdog IPSW2210 Manual Relay Output Power input 12VDC adapter LED Indicators 1 wire 2 Dry Output Green : Power Yellow: Link temperature & humidity contact inputs LED indicator sensor input
More informationSDN INSTRUCTIONS 07/10, Ver 1.2. Somfy Digital Network (SDN) Installation and Programming
Somfy Digital Network (SDN) Installation and Programming SSoomffyy SSyysst teemss IInncc.. 1 Table of Contents 1 General Information and Features... 3 1.1 ILT2 Motor... 3 1.2 SDN Switches... 4 1.3 ILT2
More informationEnergy Communication Unit (ECU)
Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.8) ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2 2.0 Installation...
More informationWxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address
Instructions Page 1 Connections The WxGoos-1 is a self-contained web server and requires 6vdc of power at 300ma. A center-positive 2.1 mm plug is used. There are five ports: 1. 10/100 Ethernet RJ-45 receptacle
More informationJob Aid Pre-Installation Information S8500 Media Server
Required information Job Aid Pre-Installation Information S8500 Media Server This job aid provides the information, hardware requirements, and computer hardware and software specifications necessary for
More informationIFS SP-PoE Splitter User Manual
IFS SP-PoE Splitter User Manual P/N 1069176-EN REV 1.01 ISS 01JUL10 2011 UTC Fire & Security. All rights reserved. Content Overview 2 Package contents 2 Introduction 3 Product Specifications 3 Hardware
More informationQuickSpecs. HP 480/277 Volt Solutions. Overview
Overview As the quest for efficiency continues it becomes apparent that what worked in the past needs improvement. More and more data center managers are looking at alternate power plans to distribute
More informationHP UPS Management Module Overview
Overview The enables you to monitor and manage power environments through comprehensive control of HP UPSs. The can support either a single UPS configuration or provides additional power protection with
More informationDominion PX. General Questions. What is Dominion PX (PX)?
Dominion PX Question General Questions What is Dominion PX (PX)? Is Raritan new to the rack power distribution unit market? Can the PX be used as a stand-alone device? Does PX work with Raritan s CommandCenter
More informationSimplify Data Acquisition with a Built-in LXI Web Server
M E A S U R E M E N T T I P S Volume 9, Number 3 Simplify Data Acquisition with a Built-in LXI Web Server Snapshot: Make temperature measurements quickly and easily There are many applications in which
More informationRemote Sources. Facility. Router
A tally display system is an essential part of any broadcast or production environment. It must tell you where signals come from, where they go, and how they are being used. In a typical multi-production
More informationSECTION 13421 PROGRAMMABLE LOGIC CONTROLLERS AND COMPUTER CONTROL SYSTEM PART 1 GENERAL. 1.01 Summary. A. Section Includes:
SECTION 13421 PROGRAMMABLE LOGIC CONTROLLERS AND COMPUTER CONTROL SYSTEM PART 1 GENERAL 1.01 Summary A. Section Includes: 1. The ISS shall furnish all labor, materials, equipment, services and incidentals
More information5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
More informationSmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire
SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire MODEL NUMBER: SU6000RT3UHV Highlights 6000VA / 6kVA / 4200W on-line double-conversion
More informationPCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
More informationLTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
More informationSentry Bulldog Shutdown Management Software (For UNIX Series)
Sentry Bulldog Shutdown Management Software (For UNIX Series) User Manual Table of Contents Introduction...4 Sentry Bulldog Installation...5 Sentry Bulldog Services...6 Sentry Bulldog Monitor...7 Networking...8
More informationDaker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
More informationQuickSpecs. Models HP Server Console G2 Switch. HP Server Console Switch G2 with Virtual Media & CAC. Overview
Overview HP's Server Console Switch with Virtual Media is a key component in managing the data center. Connections for two local consoles (a console represents one keyboard, monitor and mouse) allow access
More informationDistributing Power to Blade Servers
Distributing Power to Blade Servers Ten steps to selecting the optimal power distribution design With the growth in blade servers with dual or triple power supplies, a single rack of equipment can easily
More informationSNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use
SNMP-1000 Intelligent SNMP/HTTP System Manager Features Monitors system fans, temperature, voltage, power supply, CPU fan, CPU temperature, Vcore, watchdog timer etc. Stand alone system monitoring, no
More informationEDI Distributor Control Interface Wiring and Setup Instructions
Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls
More informationTemperature@lert WiFi Edition
Temperature@lert WiFi Edition Affordable WiFi temperature and humidity monitoring to protect your most critical assets Single or Dual Sensor Configurations available Overview Temperature@lert WiFi Edition
More informationMSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments
The MSITel module family allows your ground console to be everywhere while balloon experiments run everywhere MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments
More informationPanduit PViQ Switched POU User Manual
Panduit PViQ Switched POU User Manual Switched and Environmental Monitored Switched with Per Outlet Power and Environmental Monitored MN028 Version 2.0 Copyright 2010 PANDUIT Corp. All rights reserved.
More informationCisco Nexus 7000 Series Power Supply Modules
Cisco Nexus 7000 Series Power Supply Modules Product Overview The Cisco Nexus 7000 Series Power Supply Modules (Figures 1 and 2) deliver fault tolerance, high efficiency, load sharing, and hot-swappable
More informationOlson Electronics Remote Power Monitoring Meter
Olson Electronics Remote Power Monitoring Meter Operation Guide Key Features Amps: 00.00 to 32.00A True RMS (rated short period to 40A) Volts: 200.0 to 250.0V True RMS Watts: 0000 to 9999W KWh: 000000.0
More informationSENSAPHONE 901 Tryens Road Aston, PA 19014 PH: 877-373-2700 www.sensaphone.com
SENSAPHONE 901 Tryens Road Aston, PA 19014 PH: 877-373-2700 www.sensaphone.com Why Choose Sensaphone Sensaphone products are designed to help you watch over a remote facility. Our range of Sensaphone solutions
More informationTechnical Overview CM-16 Climate Monitor. Get yours direct at: 01491 410913 www.theclimate.co.uk
Technical Overview CM-16 Climate Monitor Get yours direct at: 01491 410913 www.theclimate.co.uk Need a lot of remote sensors in a rack mount? The CM-16 has web access, graphing, and alarm alerts sent by
More informationLegal Disclaimers. For C-UL Listed applications, the unit shall be installed in accordance with Part 1 of the Canadian Electrical Code.
ACS5000 Networking Admin Interface Guide 1/21/2015 Legal Disclaimers Federal Communications Commission (FCC) Compliancy This equipment has been tested and found to comply with the limits for a Class B
More informationAXIS 262+ Network Video Recorder
31433/EN/R4/0803 Complete Network Video Recording Solution Complete Network Video Recording Solution Picture this: A simple and reliable, plug-and-play video surveillance system for hotels, shops, banks,
More informationMONITORING. Software. M2M Transfer. Data Input. Processing. Reports Graphs, Excel Alarms. Logging Analysis, Alarms Various products
MONITORING Measurement Sensors Dry contacts Logging Analysis, Alarms Various products XML/HTTP SNMP, E-mail GPRS/SMS Reports Graphs, Excel Alarms www.hw-group.com Measurement, Sensors Temperature Humidity
More informationISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface
ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850
More informationCisco TelePresence Video Communication Server Starter Pack Express Bundle
Data Sheet Cisco TelePresence Video Communication Server Starter Pack Express Product Overview Figure 1. Cisco TelePresence Video Communication Server Starter Pack Express Bundle The Cisco TelePresence
More informationApplication/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
More information